DIN RAIL PULSE/FREQUENCY/CONDITIONER
|
|
- Jordan O’Connor’
- 6 years ago
- Views:
Transcription
1 DIN RIL /FREQUENCY/CONDITIONER SEM0F DUL OR SINGLE UNIVERSL FREQUENCY INPUT(S) PLUS EXCITTION MODES FREQUENCY (0.01 to 000) Hz ; COUNTER (DC to 00) Hz RTE/ISE, K FCTOR, M FCTOR, MTHS FUNCTIONS SECOND INPUT CTS S RE- IN SINGLE CHNNEL MODE VOLT FREE,LTCHED, CTIONS (S) CURRENT SINK/SOURCE IPOLR VOLTGE C/DC POWER SUPPLY INTRODUCTION The product is a cost effective smart powered conditioner that accepts all common process pulse signals with a frequency range between (0.01 to 000) Hz in stard configuration (DC to 00) Hz in mode. Typical applications would be to measure flow counting. The product has a built in capability to operate as a dual input which allows differential flow / count measurement with advanced maths functions. Or, as a single channel input, with an external contact. When operated in signal channel mode, the discrete input can be programmed to the total, latched relay. The input can also be programmed to control the total direction with a combination of count up /count down halt modes available. volt free output contact is provided capable of operating as a trip, latched trip pulsed trip. High low level trip functions are also available. The output stage offers voltage, bipolar voltage active / passive current re-transmission signals. The retransmission signal can be ranged to a scale anywhere within the process range. The product uses a US pt f configuration, together with a simple to use free menu driven software configuration tool, allowing the user to take advantage of the products comprehensive specification. The device can be configured to operate in three modes: Frequency to process signal mode plus trip dvanced frequency mode with K fact, M fact, totalise, rate, maths functions, process signal + trip Counter mode with K fact, totalise, maths functions, process signal + trip SUPPLY ( to ) Vdc ( to 2) Vac PSU UNIVERSL FREQUENCY INPUT Or Discrete Output Vout + INPUT US Page 1 of Externally powered Current Internal powered Current Load + V - Load
2 DIN RIL /FREQUENCY/CONDITIONER EQUIPMENT COMPUTER US CLE PC CONFIGURTION Running Windows XP later with US pt to mini METHOD Load PC with US SPEEDLINK software. Connect SEM0F US pt to PC US pt using cable. Run software, set configuration required save to device. 20 C OPERTION MODES Dual Channel Single Channel Frequency Frequency frequency discrete input INPUT TYPE Note channel offers all input sense option when set in discrete mode. In this mode channel input value is high low. Frequency Mode Frequency Min measuring Value Min cut off Min pulse width Counter Mode Min pulse width Tacho (mv) input Over voltage m Input PNP, NPN, Contact Current Max Current Max TTL input supply Namur (0.01 to 000) Hz 0.01 Hz 0.01 Hz 0 us 0.1 S 1 S (DC to 00) Hz 0 us < 0 mv > 200 mv >0 KΩ ± 0 V < 1.2 m > 2.1 m 1 KΩ 1 1 V V < 1.2 m > 2.1 m 1 KΩ < 1.0 V > 2.0 V 0 KΩ V dc ± m 1 V dc ± m VOLT FREE Max 2 V dc Current 0. dc ctions level trip, latched trip Frequency Mode Signal,, Rate,, Rate Maths, Maths. Counter Mode Signal output Frequency Mode Signal Counter Mode Signal,, Maths. Period (20 to 000) ms,, Maths.,, Maths. NLOGUE Output s Current / Frequency Mode Signal,, Rate,, Rate Maths, Maths. Counter Mode Signal,, Maths. CURRENT Output s current sink, source Current sink Supply voltage ( to 0) V dc Current source Max Load 0 R (0 to 20) m Max 21. m Output Connection Screw Terminal ccuracy (m output /2000) u (Whichever is the greater) Loop effect 0.2 u / V (Sink Mode) Thermal drift 1 u / C VOLTGE output Max Output Connection ccuracy ISOLTION Three pt GENERL SPECIFICTION Update time Response Time Start up time Warm-up time ctive Scaling Max Load current m (0 to ) V, (- to ) V. V Screw Terminal ± mv 00 V dc 0 ms 200 ms seconds (Output start up condition lags) 1 minute to full accuracy llows scaling of output against active input, Using US pt mbient stage temperature (-20 to +0) C mbient humidity range ( to 0) % RH non condensing SUPPLY ( to ) V dc ( to 2) V rms ac Power < 1 full output current Protection Internal table fuse (0. ) + Over protection. PPROVLS EMC - S EN 12 Electrical equipment f measurement control labaty use. Note - Signal input wires to be less than 0 metres to comply. NPN inputs require external 2 KΩ pull up resist. Page 2 of
3 DIN RIL /FREQUENCY/CONDITIONER CONFIGURTION DUL CHNNEL FREQUENCY MODE V 1 V dc TTL, m, PNP, NPN, Contact, mv 0 ms 1 second (0.01 to 0000) Hz (.0 to 000) Hz P override user set signal Rate Rate Low Scale process low to frequency Rate High Scale process high to frequency K fact to M fact 1 crection points direction Count up, count down halted time base Second, Minute, Hour fact (1 to 00000) Divis (1 to 0000) ± Variables Rate Units FUNCTIONS Rate (Nmally open) ction Characters Characters Characters +,, Highest, Lowest +,, Highest, Lowest High/low level trip, High/low level latched trip Rate, Rate,,, Rate Maths Maths. (1 to 0000) US power down output (nmally open), Maths (20 to 000) ms atch Reset 1 to NLOGUE PROCESS S Rate,, Rate,, Rate Maths Maths Low, High SIGNL ny within O/P ny within O/P Hz, Rate, Hz, Rate, s Rate Maths, Maths atch Logger desktop file *.txt fmat Logger Period (0.0 to 0) Minutes,, atch,, atch Reset Latched SINGLE CHNNEL FREQUENCY MODE V 1 V dc TTL, m, PNP, NPN, Contact, mv 0mS 1 second (0.00 to 0000) Hz (.0 to 000) Hz Rate Rate Low Scale process low to frequency Rate High Scale process high to frequency K fact to M fact 1 crection points direction Count up count down time base Second, Minute, Hour fact (1 to 00000) Divis (1 to 0000) ± Variables ctive ction Single multi Rate Units (Nmally open) ction TTL, m, PNP, NPN, Contact, mv Contact open (input High) Contact Closed (low input) Reset, Reset Reset. Counter control, Off, Up/Halt, down/halt up/down. Characters Characters High/low level trip, High/low level latched trip Rate,, (1 to 0000) US power down discrete output (nmally open) (20 to 000) ms atch Reset 1 to NLOGUE PROCESS S Rate,, Maths Low High SIGNL ny within O/P ny within O/P Hz, Rate, 0 1 (1 = active) atch Logger Save to desktop file *.txt fmat Logger period (0.0 to 0) Minutes, atch, atch Reset Latched Page of
4 DIN RIL /FREQUENCY/CONDITIONER RTE Scale Low nd High Process against Frequency M Fact P Hz Scale Low nd High Process against Frequency K fact Count Up/down Halt Divis, Start Up, Start Down Reset Counts FUNCTION RTE + Highest rate Lowest rate NLOGUE SIGNL Low Rate F(n)* Rate F(n)* Rate F(n)* P Count Up/down Halt Divis, Start Up, Start Down Reset Counts + Highest rate Lowest rate RELY Rate Hz Rate F(n)* Rate F(n)* point nd HighLow Latched F(n)* Histy Rate Units Units Latched F(n) *= Maths P Hz RTE Scale Low nd High Process against Frequency M Fact NLOGUE Count Up/down Divis, Start Up, Start Down Reset Counts Rate Units Units SIGNL Low DISCRETE INPUT RELY Signal Sense ctive low high Reset ction Direction ction Off Count Up/ Halt Count Down/Halt Count Up/ Down Page of point nd Histy Latched
5 DIN RIL /FREQUENCY/CONDITIONER DUL CHNNEL COUNTER MODE SINGLE CHNNEL COUNTER MODE V 1 V dc V 1 V dc TTL, m, PNP, NPN, Contact, mv direction Count up, count down halted K fact range to 000 ± Variables Max pulse rate 0 pulses per second FUNCTIONS (Nmally open) ction Characters Characters +,, Highest, Lowest High/low level trip, High/low level latched trip,, Maths. (1 to 0000) US power down output (nmally open) Maths (20 to 000) ms atch Reset 1 to NLOGUE PROCESS S,, Maths Low, High SIGNL ny within O/P ny within O/P s Maths atch Logger desktop file *.txt fmat Logger period (0.0 to 0) Minutes,, atch,, atch Reset Latched TTL, m, PNP, NPN, Contact, mv direction Count up, count down halted K fact range to 000 ± Variables Max pulse rate 0 pulses per second ctive ction Single multi Rate Units (Nmally open) ction TTL,m,PNP,NPN,Contact, mv Contact open (input High) Contact Closed (low input) Reset, Reset Reset. Counter control, Off, Up/Halt, down/halt up/down. Characters Characters High/low level trip, High/low level latched trip Rate,, (1 to 0000) US power down discrete output (nmally open) (20 to 000) ms atch Reset 1 to NLOGUE PROCESS S Rate,, Maths Low High SIGNL ny within O/P ny within O/P 0 1 (1 = active) atch Logger Save to desktop file *.txt fmat Logger period (0.0 to 0) Minutes, atch, atch Reset Latched Page of
6 DIN RIL /FREQUENCY/CONDITIONER NLOGUE Count Up/down Halt Start Count Reset Counts (up down) K fact FUNCTION Low F(n)* Count Up/down Halt Start Count Reset Counts (up down) + Highest rate Lowest rate histy RELY F(n)* SIGNL F(n)* point nd Latched Units Latched F(n) *= Maths SIGNL NLOGUE Count Up/down Divis, Start Reset Counts Low Hz DISCRETE INPUT Signal Sense ctive low high Reset ction Units RELY Counter Direction ction Off Count up / Halt Count Down / Halt Count Up / Down Histy Page of point nd Latched Latched
7 PRESSURE TRNSMITTER MECHNICL 1 2 REFER TO INSTRUCTION MNUL EFORE USE 0 mm mm. mm MECHNICL DETIL Material Polymide. self extinguishing Terminals Screw terminal Cable 2. mm Max Colour Grey Status Instruments Ltd Tel: + (0)1 21 Green Lane usiness Park Fax: + (0)1 2 Green Lane, Tewkesbury sales@status.co.uk Gloucestershire, UK Website: GL20 DE D SEM0F Data Sheet Page of
PULSE/FREQUENCY/CONDITIONER USER GUIDE
PULSE/FREQUENCY/CONDITIONER USER GUIDE D2560-02-02 CN5220 1600F USER GUIDE Page 1 of 13 PULSE/FREQUENCY/CONDITIONER USER GUIDE FREQUENCY INPUT PSU 1 2 + - SUPPLY (to4) Vdc (to32) Vac UNIVERSL Excitation
More informationSEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER
RTD, THERMOCOUPLE, THERMISTOR (BMS SENSORS), SLIDE WIRE, mv AND RESISTANCE INPUTS ma, VOLTAGE OR BIPOLAR VOLTAGE OUTPUT SENSOR OFFSET (TEMPERATURE) 22 SEGMENT USER LINEARISATION (PROCESS) CONFIGURATION
More informationSEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER
UNIVERSAL INPUT, DUAL CHANNEL ATEX & IEC Ex Version MATHS FUNCTIONS SENSOR CHARACTERISTICS DOWNLOAD VIA USB PORT ALLOWS FOR CUSTOM TYPES FLASH TESTED TO 4 KV DC INTRODUCTION The SEM210 is a universal transmitter
More informationSEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.
INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business
More informationSEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.
INDEX SECTION CONTENTS PAGE NO. SEM104 SERIES SEM104P Pt100 Temperature Transmitter SEM104TC Thermocouple Temperature Transmitter SEM104P 1 1.0 DESCRIPTION 2 2.0 SPECIFICATION 2 3.0 INSTALLATION 24 4.0
More informationS T T U S I N S T R U M E N T S
S T T U S I N S T R U M E N T S Welcome to the latest Status Instruments Product Guide Here at Status Instruments, we re very proud to say that we ve been making top-quality instrumentation for 30 years.
More informationMODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC
MODEL: MLU Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step
More informationPulse Scaler for DIN Rail Attachment
Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary
More informationS663 Preset Rate/Totalizer Counter
File# E199939 Easily programmed from the front panel Remote reset capability Input variety: Quadrature, Switch, TTL, CMOS, NAMUR, PNP, NPN Software functions include: Password Display Scaling Set Point
More informationS662 Preset Batch/Dual Counter
File# E199939 Easily programmed from the front panel Remote reset capability Input variety: Quadrature, Switch, TTL, CMOS, NAMUR, PNP, NPN Software functions include: Password Display Scaling Set Point
More informationPosition Indicator with/without Limit Values
.1 Position Indicator with/without Limit Values Large, 6-digit, 14 mm high LED display Prescaler 2 variable limit values Eeasy direct selection by 2 function keys Rrelay output with two change-over contacts
More informationHigh Performance Process & Temperature Controllers
C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal
More informationST-250MAK-05E. Switching Power Supply SPECIFICATION
Switching Power Supply (SFX-12V) SPECIFICATION Revision: 1.0 SEVENTEAM ELECTRONICS CO., LTD. 2F, No.35, Lane 167, Sec.1,Tung Ho E. St, TAIPEI, TAIWAN TEL: 886-2-2882-9050 FAX: 886-2-2882-6230 1 ** Table
More informationSeries 1700 PX. Selection Guide. Threshold relays. Process signal converters/isolators. Temperature converters
Selection Guide Threshold relays Process signal converters/isolators Temperature converters Process signal to pulse frequency converters/isolators Pulse frequency to process signal converters/isolators
More informationExcellent low-cost Process & Temperature Controllers
C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200
More information4002-ALM USER MANUAL 4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT
4002 ALM DUAL TRIP AMPLIFIER WITH RE-TRANSMITTED OUTPUT Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationMODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC
Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step Cal calibration
More informationSafety Relay Unit. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category. possible 24 VAC/VDC G9SA-501.
Sfety Rely Unit The Series Offers Complete Line-up of Compct Units. Four kinds of -mm wide Units re ville: A -pole model, -pole model, nd models with poles nd OFF-dely poles, s well s Two-hnd ler. Simple
More informationMODEL: 27HU 27-UNIT MODEL: 27HU [1][2]
Head-mounted Two-wire Signal Conditioners 7-UNIT -WIRE UNIVERSL TEMPERTURE TRNSMITTER (HRT communication) Functions & Features Universal input: DC mv, T/C, RTD and resistance High accuracy HRT communication
More informationminimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven)
Digital panel meter 5-digit M2 red display of -19999 99999 digits (optional green, orange, blue or tricolour display) minimal installation depth: 70 mm without plug-in terminal adjustment via factory default
More informationIndustrial Interface The Signal Conditioning People
Loop Powered Products including: 420TW 420i RTD/TC-HEAD Isolating Terminal Blocks Loop Powered Isolators In-Head Transmitters DC/AC Powered Isolation including: ISOCON DUALCON SLIMCON TC-TC VCON STRAIN
More informationS660 Preset Totalizer Counter
File# E199939 Easily programmed from the front panel Remote reset capability Input variety: Quadrature, Switch, TTL, CMOS, NAMUR, PNP, NPN Software functions include: Password Display Scaling Set Point
More informationIncremental encoders Solid shaft with square flange pulses per revolution
Fetures Size mm Precise opticl sensing Output signl level TTL or HTL Squre flnge 2.5 (63.5 mm) Connection xil, rdil or tngentil Pulses per revolution up to 5000 High protection up to IP 67 High resistnce
More informationTSC. Transtech Signal Conditioners. Galvanic Isolation as Standard Full Input Range Field Adjustable 0.1% Accuracy Dual Rail Mounting.
TSC Transtech Signal Conditioners Industrial AUSTRALIAN DESIGNED AND MANUFACTURED Process Galvanic Isolation as Standard Full Input Range Field Adjustable 0.1% Accuracy Dual Rail Mounting Mining Dec 2005
More informationRISH Ducer E13 3 channel transducer for AC current and voltage
RISH Ducer E13 3 channel transducer for C current and voltage The RISH Ducer E13 ( Fig. 1) converts 3 sine wave C current or C voltage into 3 output signals that can serve several receiving instruments
More informationSeries AE W PFC INDUSTRIAL POWER SUPPLY
FEATURES Progrmmle output voltge (0%~05%) Progrmmle output current (0%~05%) Universl AC input / Full rnge Constnt current limiting Optionl glol control vi RS3 Selectle +5V / 0.5A or +9V / 0.3A uxiliry
More informationSeries OLS10KD 10kW HIGH VOLTAGE POWER SUPPLY
DESCRIPTION The Series OLS10KD range of high voltage power supplies recognises the requirement for high stability and very low ripple over a wide range of output voltages. This is achieved by combining
More informationSPECIFICATION. SilverStone OLYMPIA OP1000 Switching Power Supply Active PFC
SPECIFICATION SilverStone OLYMPIA OP1000 Switching Power Supply Active PFC SilverStone Technology Co., Ltd 18F~8 NO.738 Chung-Cheng Rd., Chung-Ho City, Taipei Hsien, Taiwan R.O.C. 235 TEL: 886-2-82278222
More informationUniversal Radius Mounting Option. Fixed Radius Mounting Option
F e a t u r e s Factory Set for Same Day Dispatch (1 to 65,536 Pulses Per Rev) 100 Degrees Centegrate cabability as standard Opto-ASIC Technology Any bore - up to 15mm bore (Metric) or (Imperial) The 60HA
More informationDigital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40
Digital Panel Meters Current and Voltage Indicator/Controller Type LDM40 Multi-input instrument 4-DGT LED 0.1% RDG basic accuracy TRMS AC current and voltage measurements AC/DC current measurements: selectable
More informationUser Manual for the. Anemometer type AN3 AN3-UM-1 DELTA-T DEVICES
User Manual for the Anemometer type AN3 AN3-UM-1 DELTA-T DEVICES High Resolution anemometer, Type AN3 Operating Instructions Introduction The AN3 provides both an analogue and a digital output. It is the
More informationTechnical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity
KFU8-DW-.D Release date: 2-2- 2:8 Date of issue: 26-8- 4_eng.xml Model Number KFU8-DW-.D Rotation Speed Monitor Features Speed monitoring up to 4 khz pre-select value with relay output and LED indicator
More informationInstallation and Operating Manual
GB Analog Weight Transmitter PS-1000 Installation and Operating Manual LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section
More informationEnergy Management Modular Power Analyzers Type WM2-96
ISE, Inc. - 10100 Royalton Rd. - Cleveland, OH 44133 USA Energy Management Modular Power Analyzers Type WM2-96 - Tel: (440) 237-3200 - Fax: (440) 237-1744 - http://instserv.com Class 1 Modular power analyzer
More informationMODEL AT-10 ANALOG TRANSMITTER
MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca
More informationEnergy Management Three-phase energy meter with output modules Type EM4-DIN
Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT
More informationF-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature
F-SERIES Indicators Totalizers Transmitters Flow computers Batch controllers Monitors Flow Level Pressure Temperature FOR F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F
More information08/07/2015
17.5 mm - 1 Solid State Relay 0.7A MUS2 Part number 88827004 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external
More informationTC-600PD2. Switching Power Supply ( 600W PS2 ATX12V ) SPECIFICATION. Revision: 1.0
Switching Power Supply ( 600W PS2 ATX12V ) SPECIFICATION Revision: 1.0 727,. Phillips Drive City of Industry. CA 91748. USA http:// www.xeal.com.tw TEL: 626-303-8885 FAX: 626-301-0588 ** Table of Content
More informationTemperature Transmitter ZTT series
BT.11.13 ZT/I ZTT series The ZTT series transmitter accepts the most commonly used temperature sensors (RTD, T/C) as well as mv and slide wire signals. All the models adopt a 2 wire 4...20mA output signal
More informationDIGITAL PANEL INSTRUMENTS
M2-1V.../ M2-1T... M2-1V.../ M2-1T... Case 96 x 48 mm Programmable Digital Panel 96 x 48 mm Red display of -1999 up to 99999 (optional green, orange, blue or tricolour display) Minimal installation depth:
More informationModel FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter
Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------
More informationinstallation depth: 90 mm without plug-in terminal display flashing at threshold exceedance / threshold undershooting
Digital panel meter 5-digit M3 red display from -19999 99999 Digits (optional green, orange or blue display) installation depth: 90 mm without plug-in terminal min-/max-memory 30 additional adjustable
More informationMODEL: M2SES SEN TRONIC AG [3] OUTPUT
Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL
More information4-20mA, 0-10V and general process measuring bargraph displays
Page 1 of 6 Digital panel meters Large displays Bargraphs Transmitters 4-20mA, 0-10V process input bargraph displays Display almost any physical variable... The bargraph displays on this page accept most
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationNetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00
NetBiter I/O Extender 4RO 6RTD 8DIO DAIO User Manual Revision 1.00 IntelliCom Innovation AB Linjegatan 3D SE302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 18 21 99 email info@intellicom.se www
More informationPreset counters, electronic
The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their
More informationEnergy Management Energy Meter with plug-in Output Modules Type EM4-DIN
Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Degree of protection (front): IP 40 Front dimensions: 9 DIN modules RS 422/485 Serial port by means of optional module Dual pulse
More informationTechnical Data Sheet. x1000. kwh R Y B
Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy
More informationRISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:
(With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network
More informationMultifunctional counter tico 772/773/774
Universally applicable as a tachometer, timer, shift counter, batch counter Easy to operate Four different backlight colours Intensity of backlighting can now be adjusted Large, clearly readable 48 x 48
More informationUniStream Uni-I/O Modules
UniStream Uni-I/O Modules Technical Specifications UIS-WCB1 This guide provides specifications for Unitronics Uni-I/O Wide module UIS-WCB1. This module comprises: 10 Digital inputs, 24VDC, sink/source,
More informationMODEL: TC10EM. Temperature Controller TC10 Series
Temperature Controller TC0 Series TEMPERTURE CONTROLLER (Modbus, 5 digit, LED display type, size 9 x 9 mm) Functions & Features Two PID controllers* Universal input x points, control output x points, discrete
More informationCONTA-ELECTRONICS. Converter Units
CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to
More informationMODEL: W2DYS SEN TRONIC AG. Mini-MW Series
MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters
More information4 channels High Speed Counter Unit
2/4 channels High Speed Counter Units 2 or 4 Channels High Speed Counter Units for CS PLC. Frequency up to 500 khz, closed loop response time as low as 0. ms. 4 Digital In, 4 Digital Out and 28 soft outputs
More informationSeries OLH10KD 10kW HIGH VOLTAGE POWER SUPPLIES
Series OLH10KD FEATURES 10kW of output power Wide dynamic range with dual supply configuration Output voltages from 60kV to 500kV for high range Output voltages from 6kV to 10kV for low range Robust IGBT
More informationMODEL: M2DYS SEN TRONIC AG
Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical
More informationECT-DIN. Features. Signal Isolator, Converter, Repeater, Booster and Splitter. Isolate Signals to stop erratic measurements caused by ground loops.
-DIN pril 2016 Description DIN-style signal isolators, converters, repeaters, boosters and splitters feature solid metal housings that stand up to the continuous, daily rigors of process control and factory
More information02/11/2015
DIN Rail Mount 17.5 mm MXR1 Part number 88826185 Just one digit differentiates the new range part number from the old range's Previous part number : 88 826 XXX / new part number : 88 827 XXX Part numbers
More informationDP2000 ORDERING GUIDE To Order MODEL NO.
1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition
More informationDSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.
15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty
More informationFREQUENCY => CURRENT / VOLTAGE CONVERTER Z111
EN FREQUENCY => CURRENT / VOLTAGE CONVERTER Z111 GENERAL FEATURES Pulse input for all the most commonly-used sensors: mechanical contact, reed, npn with 2 and 4 wires, pnp with 3 wires and 24V DC power
More informationUSB-TEMP and TC Series USB-Based Temperature Measurement Devices
USB-Based Temperature Measurement Devices Features Temperature and voltage measurement USB devices Thermocouple, RTD, thermistor, or semiconductor sensor measurements Eight analog inputs Up to ±10 V inputs*
More information- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION
ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS
More informationOPTICAL ISOLATOR ELECTRONIC MODULE
OPTICL ISOLTOR ELECTRONIC MODULE ELECTRICL SPECIFICTIONS POWER: The optical isolator can accommodate standard operating voltages from 5 to 28 VDC. It should never be connected directly to C power mains.
More informationPower analyzers and Energy Meters Power Analyzer Type WM14-DIN
Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)
More information08/07/2015
17.5 mm - 1 Relay 8A MUR1 Part number 88827105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external load connection
More informationDale Power Solutions Ltd
DC SWITCH TRIPPER CHARGER DATASHEET Features Erskine STU 110W Range 24V, 30V, or 48VDC nominal Constant voltage current limited charger output Standard alarms LCD voltmeter LED indica ons Equipped with
More informationType Nominal voltage (V) Code HSV V
Speed control Speed control relay - mm Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - -wire PNP or NPN, Namur, voltage 0-0V or volt-free contact type Works
More informationRI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current
More informationSL7000 Series. Universal Input Data Loggers
SL7000 Series Universal Input Data Loggers Unit E2, Green Lane Business Park Tewkesbury, Gloucestershire, GL20 8SJ Telephone: +44 (0)1684 299 399 Email: sales@signatrol.com SL7000 Series Universal Input
More informationcontrol & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS
S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip
More informationR7420B. MicroniK 100 HONEYWELL TEMPERATURE CONTROLLER PRODUCT DATA GENERAL FEATURES
HONEYWELL MicroniK 1 R742B TEMPERATURE CONTROLLER GENERAL PRODUCT DATA The temperature controller R742B uses direct digital control technology to provide a more accurate and efficient operation of heating,
More informationRISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:
Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit
More informationMECHANICAL RF STAT INSTRUCTION MANUAL MECHANICAL RF STAT TRANSMITTER & RECEIVER FITTING & OPERATING INSTRUCTIONS
MECHNICL RF STT FOR GREENSTR HE, SiII & i JUNIOR MODELS INSTRUCTION MNUL FITTING & OPERTING INSTRUCTIONS CONTCT INFORMTION MNUL INFORMTION WORCESTER OSCH: TECHNICL: 08705 4 SERVICE: 08547 50 SPRES: 0905
More informationAll specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.
KEY FEATURES Din Rail Switching Power Supply 180 Watt with 18CFM FAN for 12V to 48V Output Voltage 150 Watt with 30CFM FAN for 5V Output Voltage High Efficiency up to 93% Universal Input: 90-264 VAC Low
More informationECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings
ECP225- Series C-DC Power Supplies 225 Watts Low Profile High Power Density 3 by 5.0 Footprint 50 W Convection/ 225 W Force Cooled Ratings 5 V Standby and 2 V Fan Outputs Medical and ITE pprovals High
More informationBASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter
Shimaden, Temperature and Humidity Control Specialists C %RH CP3701: Thermocouple Temperature Converter CP3702: R.T.D. Temperature Converter CP3703: mv DC-DC Converter CP3704: V/mA DC-DC-Converter CP3705:
More informationHigh-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals
Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationinstallation depth: 90 mm without plug-in terminal 30 additional adjustable setpoints permanent MIN/MAX-value recording volume measuring (totaliser)
Digital panel meter 5-digit M3 red display from -19999 99999 Digits (optional green, orange or blue display) installation depth: 90 mm without plug-in terminal adjustment via factory default or directly
More informationE2Q5. Square Proximity Sensor. Long Distance Square Inductive Proximity Sensor. Ordering Information
ASH & ALAIN INDIA PVT LTD S-00, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-0020(India) Tel : 0-4797575 Fax : 0-4797574 E-mail : sales@ashalain.com Long Distance Square Inductive Square M2 Plug-in
More informationMonitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01
Monitoring Relays -Phase rue RMS AC/DC Over and nder Current ypes DC0, PC0 DC0 PC0 RMS AC/DC over + under, over+over, under+under current and voltage monitoring relays DC process signal plus/minus monitoring
More informationMonitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01
Monitoring Relays -Phase rue RMS AC/DC Over and nder Current ypes, PC0 PC0 RMS AC/DC over + under, over+over, under+under current and voltage monitoring relays DC process signal plus/minus monitoring relay
More informationMULTIFUNCTION GRAPHICAL UNIT MGU 800
MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible
More informationIncremental encoders Solid shaft with clamping or synchro flange pulses per revolution
Incrementl encoders Solid shft with clmping or synchro flnge 0 5000 pulses per revolution ExEIL580 - solid shft Fetures Size mm Precise opticl sensing Output signl level TTL or HTL Clmping or synchro flnge
More informationIncremental encoders Solid shaft with clamping or synchro flange pulses per revolution programmable (interpolated system)
Incrementl encoders Solid shft with clmping or synchro flnge 1 6556 pulses per revolution progrmmle (interpolted system) EIL580P - solid shft - OptoPulse Fetures Size mm Precise opticl sensing (interpolted)
More informationDIGEM f 96 x 48 EK. Applications. Description
3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel
More informationC330 / C330X PC-Programmable Universal, 2-wire Transmitter
C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and
More informationFC Series Signal Conditioners
FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between
More information1500W Programmable Single Output AK V. 48V Rated Current. 31.3A Current Range 100A. 0~31.3A Rated Power 0~100A 1500W
500W Programmable Single Output AK-500 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (40% ~ 05%) +5V / 0.5A auxiliary output High power
More informationPower Supply Unit (550W)
Contents Power Supply Unit (550W) Chapter 3.1 GENERAL DESCRIPTION...3.1-1 APPLIED VOLTAGE...3.1-2 INPUT CURRENT...3.1-2 DC OUTPUT...3.1-3 VOLTAGE DROPOUT...3.1-4 OUTPUT ISOLATION...3.1-4 OVERLOAD/UNDERLOAD
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More information100mm Recorders Specification Sheet
4103C, 4103M MODELS 100mm Recorders Specification Sheet The 4103 is a high specification, 100mm strip chart recorder, providing continuous recording for up to 6 Process Variables. Information such as Channel
More informationSwitched mode power supply for DIN rail mounting type SMP23 DC24V/40A
Switched mode power supply for DIN rail mounting type SMP DC4V/40A Description Switched mode power supply (SMP) for rail mounting, three-phase supply voltage, high efficiency, integral input filter and
More informationModbus I/O. RS-485 to 3-wire Universal 50W Power Supply
Modbus I/O Configuration Kit Software Interface Package Model No. 900C-SIP RS- to Converter (non-isolated) Configuration Software for Windows Cable (-9) Software Interface Package This package includes
More informationSpecifications. PCI Bus. Analog Input Input Characteristics
Specifications A This appendix lists the specifications of the NI 6034E/6035E/6036E. These specifications are typical at 25 C unless otherwise noted. The first section provides the specifications for the
More informationSDM3045X Digital Multimeter. DataSheet
SDM3045X Digital Multimeter DataSheet-2016.06 User-friendly Design Product Overview SDM3045X is a 4½ digit digital (60000 count) multimeter incorporating a dual-display and is especially well suited for
More information