CONTROL DA220C5300 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS.

Size: px
Start display at page:

Download "CONTROL DA220C5300 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS."

Transcription

1 CONTROL DAC5 I P E + - >> KL4a LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS No. 465 English FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS GMBH & CO KG SINGAPORE PTE. LTD.

2 EFKA DAC5 CONTENTS Page Putting into Service 5 Setting and Putting into Service with the Aid of the Fast Installation Routine (SIR) 5 Operating Elements and Socket Connectors 6. Position of Operating Elements and Displays 6. Position of the Socket Connectors 7. Connection Diagram 8.4 Connection of a Sewing Light with Transformer 4 Connection Scheme of SMA Stepping Motor Control 5 Timing Diagrams 6 List of Parameters 9 6. Operator Level 9 6. Technician Level 6. Supplier Level 6 7 Error Displays 6 8 Slide-in Strips for V8/V8 Control Panels 7

3 5 EFKA DAC5 Putting into Service Before putting the control into service, the following must be ensured, checked and/or adjusted: The correct installation of the drive, position transmitter and accompanying devices, if necessary If necessary, the correct adjustment of the direction of motor rotation using parameter 6 The correct positioning speed using parameter The correct maximum speed compatible with the sewing machine using parameter The setting of the positions The setting of the remaining relevant parameters Start sewing in order to save the set values See instruction manual for details! Setting and Putting into Service with the Aid of the Fast Installation Routine (SIR) The Fast Installation Routine (SIR) passes through all parameters necessary for programming the functional sequence and the positions. Code E F- Input parameter 5 F-5 E > Parameter for direction of motor rotation Parameter for transmission ratio Important! The transmission ratio should be determined and indicated as precisely as possible. Parameter for type of position sensor Parameter for position Parameter for position F-6 E F-7 E F-7 E F-45 E F-45 Yes E No P End SIR KL58 The values can be varied by pressing the +/- keys. When the parameter is displayed on the V8 control panel, press the E key once more for the value to be displayed. Exit the routine any time by pressing the P key once, and select a new parameter. Exit programming by pressing the P key twice, and the drive is ready for a new sewing operation. See instruction manual for details!

4 EFKA DAC5 6 Operating Elements and Socket Connectors. Position of Operating Elements and Displays S S S S4 S5 LED P key Call or exit programming mode E key Start backtack single / double / off Enter key for modifications in the programming mode + key End backtack single / double / off Increase of the value indicated in the programming mode key Automatic sewing foot lifting at stop in the seam On/Off Automatic sewing foot lifting after thread trimming On/Off Decrease of the value indicated in the programming mode >> key Basic position or Shift key in the programming mode Indicator for single start backtack I LED LED LED4 LED5 LED6 Indicator for double start backtack Indicator for single end backtack Indicator for double end backtack Indicator for automatic sewing foot lift at stop in the seam Indicator for automatic sewing foot lift after the thread trimming operation Display LED LED LED LED4 LED5 LED6 LED7 LED8 P E + - S S S S4 S5 LED7 Indicator for basic position needle position LED8 Indicator for basic position needle position Display digits KL

5 7 EFKA DAC5. Position of the Socket Connectors B Socket for commutation transmitter B8 Socket for light barrier module / Hall sensor module / pulse encoder / EFKANET (Adapter cord 9 in case of multiple assignment) B4 Socket for motor power supply B4 B4 M B8 B776 Socket for actuator Socket for V8/V8 control panel B B M B8 B8 ST Socket for solenoid inputs and outputs / solenoid valves / displays / keys and switches B8 B8 IPG... HSM... LSM... EB... B776 V8.. B776 Adapter 9 LSM...+ HSM... LSM...+ IPG... ST A A KL56

6 EFKA DAC5 8. Connection Diagram Socket ST corresponds to socket A ATTENTION! When connecting the outputs, ensure that a total power of 96VA constant load will not be exceeded! in - Key for output B i - Backtack suppression/recall M9 - LED righthand thread monitor in - Machine run blockage M - Thread trimmer M - LED for output A in - Needle up/down M - Needle cooling M - LED for output B in4 - Key for output A M - Thread wiper FL - Sewing foot lifting in5 - Intermediate backtack M4 - Thread tension release VR - Backtacking in6 - Thread monitor M5 - Output B POS - Position in7 - DB M6 - Output A POS - Position in8 - DB M7 - LED lefthand thread monitor GEN - Generator impulses in9 - External light barrier M8 - LED backtack suppression/recall R-N-EXT - External potentiometer for speed limitation (5kΩ) ) Nominal voltage 4V, no-load voltage max. V momentarily after power on ) Transistor output with open collector (max. 4V, ma) ) Nominal voltage 5V, I max = ma 4) Nominal voltage 5V, I max = ma *) Front view of the socket (component side) and/or rear view of the plug (soldering side)

7 9 EFKA DAC5 POS OUT - Output for position POS IN - Input for positions G/G OUT - Output of generator impulses TXD/RXD - Serial transmission lines LSM IN - Possibility of connecting a light barrier module to socket B8/8 LSM - Reflection light barrier module HSM... - Hall sensor module IPG... - Pulse encoder EB.. Actuator Pedal step - - ½ Input A L L H H H L L H H L L H H L L H Input B L H H L L L H H H H L L L L H H Input C H H H H L L L L L L L L H H H H Input D H H H H H H H H L L L L L L L L ) Nominal voltage 5V, I max = ma ) Transistor output with open collector (max. 4V, ma) *) Front view of the socket (component side) and/or rear view of the plug (soldering side)

8 EFKA DAC5.4 Connection of a Sewing Light with Transformer ATTENTION! Before opening the cover, turn power off! Switch off the control and remove power plug from outlet Unscrew the control unit from the machine table Loosen screws (A) each at the front and at the rear Open the left part of the housing Pull the sewing light cable through the cable bushing Area (B): Connect strands with clamp on the printed circuit board Insert earth lead into plug-in device on the housing Close and screw-connect the housing Mount the control unit on the machine table B A I P E + - >> KL99a CAUTION! When the sewing light is connected, it is always current-carrying (V), even if the control unit is switched off! Only one sewing light with transformer can be connected to the control unit!

9 EFKA DAC5 4 Connection Scheme of SMA Stepping Motor Control mot V8/V8 DC5/55 variocontrol 8 P E variocontrol P E M 4 SM B5 B5 M mot B4 B4 M B776 B B8 B776 V8.. B M EB... B8 B8 B9 B8 B776 B8 control LSM... B9 B8 LSM... V8.. B776 Nr.7 ST ST ST ST I SM... DAC.../DAG... KL58 The DAC... / DAG... d.c. controls (B8) and the SMA...stepping motor control (B8) are connected by means of adapter cord no. 7. If a light barrier is required for the sewing process, it must be connected to socket B9 on the stepping motor control. The light barrier signal is transmitted via the connecting cable from the SMA to the sewing drive. Should an IPG pulse encoder or a HSM Hall sensor module be necessary besides the light barrier module, use adapter cord no. 9, which is to be connected to socket B9 of the SMA... stepping motor control. Unless a stepping motor control is provided, adapter cord no. 9 for light barrier module and pulse encoder or Hall sensor module is connected to socket B8 of the sewing drive.

10 EFKA DAC5 5 Timing Diagrams Trimming from full machine run - + / - - n n n n4 n7 n7 POS. A/ POS. tfa A/ FL t c c t8 t c t9 c4 t7 t4 t5 A/5 VR A/4 M (FA) ifa A/7 M4 (FSPL) FSE FSA A/6 M (FW) t6 A/7 M A/8 (ML) 67/FALAUF Mark Function Parameter Control V8 V8 Double start backtack with stitch correction On Key S Key Key Double end backtack with stitch correction On Key S Key Key 4 n Maximum speed n Start backtack speed n4 End backtack speed n7 Trimming speed 6 c Start backtack stitches forward c Start backtack stitches backward c End backtack stitches backward c4 End backtack stitches forward t8 Start backtack stitch correction 5 t9 End backtack stitch correction 5 ifa Activation angle of the thread trimmer 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 9 tfa Stop time for thread trimmer 9 t Delay until speed release after start backtack t Start delay from lifted sewing foot t4 Full power of sewing foot lifting t5 Pulsing of sewing foot lifting 4 t6 Thread wiper ON period 5 t7 Sewing foot switch-on delay after thread wiper 6

11 EFKA DAC5 Machine run with intermediate stop - + / - - n n n n n n4 n7 n7 POS. A/ POS. tfa A/ FL t c t c t7 t4 t5 A/5 VR A/4 M (FA) ifa A/7 M4 (FSPL) FSE FSA A/6 M (FW) t6 A/7 M (ML) A/8 67/LAUFZW Mark Function Parameter Control V8 V8 Single start backtack On Key S Key Key Single end backtack On Key S Key Key 4 n Positioning speed n Maximum speed n Start backtack speed n4 End backtack speed n7 Trimming speed 6 c Start backtack stitches backward c End backtack stitches backward ifa Activation angle of the thread trimmer 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 9 tfa Stop time for thread trimmer 9 t Delay until speed release after start backtack t Start delay from lifted sewing foot t4 Full power of sewing foot lifting t5 Pulsing of sewing foot lifting 4 t6 Thread wiper ON period 5 t7 Sewing foot switch-on delay after thread wiper 6

12 EFKA DAC5 4 Trimming from intermediate stop - + / - - n n6 n n n n4 n7 n7 POS. A/ POS. SSc tfa A/ FL t c t t c t7 A/5 VR A/4 M (FA) ifa A/7 M4 (FSPL) FSE FSA A/6 M (FW) t6 A/7 M A/8 (ML) 67/FAZW Mark Function Parameter Control V8 V8 Single start backtack On Key S Key Key Single end backtack On Key S Key Key 4 Softstart 4 = n Positioning speed n Maximum speed n Start backtack speed n4 End backtack speed n6 Softstart speed 5 n7 Trimming speed 6 c Start backtack stitches backward c End backtack stitches backward SSc Softstart stitches ifa Activation angle of the thread trimmer 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 9 tfa Stop time for thread trimmer 9 t Delay until speed release after start backtack t Start delay from lifted sewing foot t6 Thread wiper ON period 5 t7 Sewing foot switch-on delay after thread wiper 6

13 5 EFKA DAC5 End sensing by light barrier - + / - - n n n5 n4 n7 n7 POS A/ POS. tfa A/ FL t LS c t7 t4 t5 A/5 VR A/4 M (FA) ifa A/7 M4 (FSPL) FSE FSA A/6 M (FW) t6 A/7 M (ML) A/8 LS 67/ENDELS Mark Function Parameter Control V8 V8 Start backtack Off Key S Key Key Single end backtack On Key S Key Key 4 Light barrier 9 = Light barrier covered/uncovered = n Maximum speed n Start backtack speed n5 Speed after light barrier sensing 4 n7 Trimming speed 6 c End backtack stitches backward LS Light barrier compensating stitches 4 ifa Activation angle of the thread trimmer 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 9 tfa Stop time for thread trimmer 9 t Start delay from lifted sewing foot t4 Full power of sewing foot lifting t5 Pulsing of sewing foot lifting 4 t6 Thread wiper ON period 5 t7 Sewing foot switch-on delay after thread wiper 6

14 EFKA DAC5 6 Seam end by stitch counting - + / - - n n n4 n7 n7 POS. A/ POS. tfa A/ FL t Stc c c4 t7 t4 t5 A/5 VR A/4 M (FA) ifa A/7 M4 (FSPL) FSE FSA A/6 M (FW) t6 A/7 M (ML) A/8 67/ENDEZAE Mark Function Parameter Control V8 V8 Start backtack Off Key S Key Key Double end backtack On Key S Key Key 4 Stitch counting 5 = Speed mode stitch counting (limited speed) 4 = n4 End backtack speed n7 Trimming speed 6 n Automatic speed for stitch counting 8 c End backtack stitches backward c4 End backtack stitches forward Stc Stitches of the seam with stitch counting 7 ifa Activation angle of the thread trimmer 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 9 tfa Stop time for thread trimmer 9 t Start delay from lifted sewing foot t4 Full power of sewing foot lifting t5 Pulsing of sewing foot lifting 4 t6 Thread wiper ON period 5 t7 Sewing foot switch-on delay after thread wiper 6

15 7 EFKA DAC5 Machine run with ornamental backtack - / n n n n n n n n n4 n n4 n7 n7 POS. A/ POS. A/ FL t SAv tsr SAr tsr SAr t tsr SEr tsr SEv tfa A/5 VR A/4 M (FA) A/7 M4 (FSPL) A/6 M (FW) A/7 M (ML) A/8 ifa FSE FSA t6 67/LAUFZVR Mark Function Parameter Control V8 V8 Double start backtack On Key S Key Key Double end backtack On Key S Key Key 4 Ornamental backtack 5 = n Positioning speed n Maximum speed n Start backtack speed n4 End backtack speed n7 Trimming speed 6 SAv Number of start ornamental backtack stitches forward 8 SAr Number of start ornamental backtack stitches backward 8 SEr Number of end ornamental backtack stitches backward 8 SEv Number of end ornamental backtack stitches forward 8 ifa Activation angle of the thread trimmer 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 9 tfa Stop time for thread trimmer 9 t Delay until speed release after start backtack t Start delay from lifted sewing foot t6 Thread wiper ON period 5 tsr Stop time for ornamental backtack

16 EFKA DAC5 8 Machine run with high lift for walking foot - + / - - n n n n n n4 n7 n7 POS A/ POS. tfa A/ FL t t cb thp t7 A/5 VR c c c c4 A/4 M (FA) A/7 M4 (FSPL) A/6 ifa FSE FSA M A/7 M A/8 (FW) (ML) t6 M5 (HP) A/ M (LHP) A/ HP A/7 67/LAUFHUB Mark Function Parameter Control V8 V8 Double start backtack On Key S Key Key Double end backtack On Key S Key Key 4 High lift for walking foot operational mode not stored 8 = Output B high lift for walking foot 55 = n Maximum speed n Start backtack speed n4 End backtack speed n7 Trimming speed 6 n High lift walking speed 7 c Start backtack stitches forward c Start backtack stitches backward c End backtack stitches backward c4 End backtack stitches forward thp High lift walking speed run-out time 5 ifa Activation angle of the thread trimmer 5 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 9 tfa Stop time for thread trimmer 5 t Delay until speed release after start backtack t Start delay from lifted sewing foot t6 Thread wiper ON period 5 t7 Sewing foot switch-on delay after thread wiper 6 cb Number of stitches output B high lift for walking foot 58

17 9 EFKA DAC5 6 List of Parameters 6. Operator Level Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω c Number of stitches of start backtack stitches 54 A forward c Number of stitches of start backtack stitches A backward c Number of stitches of end backtack stitches 54 A backward c4 Number of stitches of end backtack stitches 54 5 A forward 4 LS Light barrier compensating stitches stitches A (for long stitches) 5 LSF Number of stitches of the light barrier filter stitches 54 A for knitted fabrics 6 LSn Number of light barrier seams 5 A 7 Stc Number of stitches for the seam with stitch stitches 54 A counting 8 -F- A parameter from the technician level is assigned to 8 H key 9 on the V8 control panel = Softstart On/Off = Ornamental backtack On/Off = High lift for walking foot (only if parameter 5 or 55 = ) oprational mode stored = On / operational mode not stored = Off 4 = Needle cooling On/Off (only if parameter 85 = ) 5 = Signals A and/or A On/Off with slide-in strips...4 (lefthand arrow = A, righthand arrow = A) 6.= Signal A On/Off 7 = Signal A On/Off 8 = No function 9 LS Light barrier On/Off A cls Light barrier compensating stitches stitches A (for normal stitch length) FA Thread trimmer On/Off A 4 FW Thread wiper On/Off J 5 StS Stitch counting On/Off A AFL Automatic sewing foot lifting with pedal forward E at the seam end, if light barrier or stitch counting is On = Automatic sewing foot Off = Automatic sewing foot On 8 SAv Number of start ornamental backtack stitches 54 A stitches forward 8 SAr Number of start ornamental backtack stitches 54 A stitches backward 8 SEr Number of end ornamental backtack stitches 54 A stitches backward 8 SEv Number of end ornamental backtack stitches 54 A stitches forward 85 cfw Number of stitches for bobbin thread stitches 5 C **) monitor parameter 95 =... Note: At the operator level, the parameter number (F-xxx) is not shown on the display, but the abbreviation (e. g. c) and the actual value (e. g. for stitches). **) When programming the -digit or 4-digit control parameter values (without control panel), the -digit or -digit value displayed must be multiplied by.

18 EFKA DAC5 Bediener-Ebene Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω 86 cf4 Number of stitches for bobbin thread stitches 55 H ***) monitor parameter 95 = 4 At this setting, the following functions will be activated upon pressing the appropriate key: > sec. = Bobbin thread monitor function is deactivated. < sec. = Counter is set to preset value. 87 chr = Manual backtack at speed n stitches 55 H (parameter 89) 55 = Manual ornamental backtack at speed n9 (parameter 88) ***) When programming the 5-digit (max) parameter values on the control or control panel, the -digit value displayed must be multiplied by.

19 EFKA DAC5 6. Technician Level Code no. 9 with control operation / Code no. 97 with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω SSc Number of softstart stitches stitches 54 A n Positioning speed RPM A**) n- Upper limit setting range of the maximum RPM 6 n_ A**) speed n Start backtacking speed RPM A**) n4 End backtacking speed RPM A**) 4 n5 Speed after light barrier sensing RPM A**) 5 n6 Softstart speed RPM A**) 6 n7 Trimming speed RPM A**) 7 n High lift walking speed RPM A**) 8 n Automatic speed for stitch counting RPM A**) 9 nst Speed stage graduation A = linear = slightly progressive = highly progressive nnk Whenever this speed is exceeded, RPM 6 H**) needle cooling is activated, if parameter 85 is set at n_ Lower limit setting range of the maximum RPM n A**) speed tns End backtack synchronization time ms 5 4 A 4 nrs End backtack synchronization speed RPM B**) 5 na Start backtack speed if backtack can be RPM H**) interrupted by pedal in pos. (neutral) (pa. 64) 6 ne End backtack speed if backtack can be RPM H**) interrupted by pedal in pos. (neutral) (pa. 64) 7 AkS Audible signal On/Off A 8 Asd Start delay, when command start is ms A**) given by covering the light barrier (see parameter 9) 9 ALS Automatic start by light barrier On/Off: A machine start by covering the light barrier, without having heeled the pedal back to the basic position. Additional prerequisites: - Parameter = - Function light barrier sensing switched on on the control panel - Initiation of the first normal seam section (pedal in the basic position) - Cover light barrier - Press pedal forward - Keep pedal pressed forward Deactivate this function by heeling the pedal back to the basic position. LSF Light barrier filter for knitted fabrics On/Off A LSd = Light barrier sensing covered A = Light barrier sensing uncovered LSS = Machine start possible with light barrier A uncovered or covered. = Machine start blocked with light barrier uncovered if parameter =. Machine start blocked with light barrier covered if parameter =. **) When programming the -digit or 4-digit control parameter values (without control panel), the -digit or -digit value displayed must be multiplied by.

20 EFKA DAC5 Technician Level Code no. 9 with control operation / Code no. 97 with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω LSE Thread trimming operation, when completing the A seam after light barrier sensing On/Off 4 SSt Softstart On/Off A 5 SrS Ornamental backtack On/Off A 6 FAr = Trimming stitch forward and thread wiper 6 5 J function On = Trimming stitch backward and thread wiper function On = Trimming stitch forward with short trimmer signal instead of a thread wiper = No function 4 = No function 5 = Thread clamp with trimming stitch backward 6 = Thread clamp with trimming stitch forward 7 SLU Stitch length during backtack A = long stitches = normal stitches 8 hpr = High lift for walking foot A operational mode not stored = High lift for walking foot operational mode stored 9 nis Display of machine speed On/Off A 4 nh Mode needle UP/DOWN (key on A/6) 4 A = Needle up = Needle up/down = Single stitch 4 = Needle up if outside pos. 4 SGn Speed status for the seam with stitch counting 4 E = Speed controllable by the pedal up to the set maximum speed (parameter ) = Fixed speed (parameter 8) without influence by the pedal (machine stop by pressing the pedal to the basic position) = Limited speed controllable by the pedal up to the set limit (parameter 8) = At fixed speed (parameter 8) can be interrupted by full heelback 4 = At fixed speed (parameter ) can be interrupted by full heelback. 4 SFn Speed status for the free seam and for the seam A with light barrier = Speed controllable by the pedal up to the set maximum speed (parameter ) = Fixed speed (parameter 8) without influence by the pedal (machine stop by pressing the pedal to the basic position) = Limited speed controllable by the pedal up to the set limit (parameter 8) = At fixed speed (parameter 8) can be interrupted by full heelback 5 t8 Stitch correction of the double start ms 5 A backtack (prolongation of the stitch regulator ON period / not effective with ornamental backtack) 5 t9 Stitch correction of the double end ms 5 A backtack (prolongation of the stitch regulator ON period / not effective with ornamental backtack) 5 thp Run-out time of the high lift walking speed ms 5 8 A 5 brt Braking power at machine standstill A

21 EFKA DAC5 Technician Level Code no. 9 with control operation / Code no. 97 with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω 54 FkL = Thread clamp Off J = Enabling thread clamp (pa. 55) and disabling thread clamp (pa. 56). If param. 55 and 56 are set to or identical values, the thread clamp is Off. = Enabling thread clamp at 5 degrees and J disabling at 4 degrees = As with pa. 54= and additional enabling of J sewing foot lift from 5 to degrees (sewing foot lift pulsing as set using pa. 4) 55 k Enabling thread clamp degrees 59 H 56 k_ Disabling thread clamp degrees 59 H 6 dre Direction of motor rotation A = Clockwise rotation = Counterclockwise rotation 7 Sr Setting the reference position: ****) A - Press the E key. - Press the >> key. - Turn handwheel until symbol on display goes off. Then position the notch on the handwheel to - marking F on the machine. 7 Sr Setting the needle positions: ****) Press the E key. Press the >> key. E = Position (leading edge) degrees J Press the E key. E = Position (leading edge) J Press the E key. A = Position (trailing edge) H Press the E key. A = Position (trailing edge) H (for changing the values turn handwheel or press the +/- key) Press the P key twice. Settings are completed! 7 Sr Display on the control: Pos. to A (LED 7 lights up) Pos. to A (LED 8 lights up) 7 Sr Display on the V8 control panel: Pos. to A (lefthand arrow above key 4 On) Pos. to A (righthand arrow above key 4 On) 7 Sr Display on the V8 control panel: Pos. to A (lefthand arrow above key 7 On) Pos. to A (righthand arrow above key 7 On) 7 Sr4 Checking of the signal outputs and inputs using the incorporated control panel or the V8/V8 control panels - Select the desired output using the +/- key - Activate the selected output using the >> key = Backtacking on socket A/4 = Sewing foot lift on socket A/5 = Thread trimmer on socket A/7 4 = Thread wiper on socket A/7 5 = Needle cooling on socket A/8 6 = Thread tension release on socket A/6 7 = Output B on socket A/ 8 = LED for output A on socket A/ 9 = Output A on socket A/ = LED righthand thread monitor on socket A/5 ****) For more detailed instructions see instruction manual!

22 EFKA DAC5 4 Technician Level Code no. 9 with control operation / Code no. 97 with control panel operation Parameter Designation Unit Limits Preset for Ind. = LED backtack suppression/recall on socket A/4 = LED lefthand thread monitor on socket A/ = LED for output A on socket A/9 max min Ω Ω 68Ω Ω OFF/ON = By actuating the switches connected to the control, the function of these switches is checked and ON/OFF is displayed on the V8/V8 control panels 79 Sr5 Control program number with index and identification number. Upon pressing the appropriate key, the data will be displayed in succession. Control display (EXAMPLE only): Press the E key Display e. g. Sr5 Press the >> key Progr. No. 5 Press the E key Progr. No. 5 Press the E key Index A Press the E key Ident. No. 98 (+) Press the E key Ident. No. 4 (+4) Press the E key Ident. No. (5+6) Press the E key Ident. No. 6 (7+8) Press the P key twice Display dac V8 control panel display (EXAMPLE only): Press the E key Display e. g. Sr [ ] Press the >> key Display e. g. 55A Press the E key Display e. g. 989 Press the E key Display e. g. 5 Press the P key twice Display dac V8 control panel display (EXAMPLE only): Press the E key Display F-79 Sr5 [ ] Press the >> key Display e. g. 55A Press the E key Display e. g Press the P key twice Display 4 dac 8 rd Number of reversing increments degrees H 8 drd Switch-on delay of reverse motor rotation ms 99 A 8 Frd Reverse motor rotation On/Off A 8 t5 Switch-off delay of needle cooling after ms A**) stop 85 Fnk Function of the output needle cooling H = Needle cooling = Under-edge trimmer = Needle cooling depending on speed (the switch speed can be set using pa. ) **) When programming the -digit or 4-digit control parameter values (without control panel), the -digit or -digit value displayed must be multiplied by.

23 5 EFKA DAC5 Technician Level Code no. 9 with control operation / Code no. 97 with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω 88 hp Minimum speed level for high lift for walking foot A Maximum speed level for high lift for walking foot A Assignment of maximum speed (parameter ) and minimum speed (parameter 7 = high lift walking speed) to the speedomat levels. Display example: = Display of the level up to which the maximum speed is effective. 9 = Display of the level up to which the minimum speed is effective. = Display of the level set on the speedomat (potentiometer). 74 = Corresponding speed See instruction manual on how to change the setting! 9 ifa Activation angle of the thread trimmer degrees H 9 FSA Switch-off delay of thread tension release ms A 9 FSE Switch-on delay angle of thread tension degrees H release 9 tfa Thread trimmer stop time ms 5 A 94 FAE Switch-on delay angle of thread timmer degrees 59 H 95 rfw Bobbin thread monitor 4 C = No bobbin thread monitor function. = Model 7 or short seams. Without stop, sewing foot down after thread trimming. = Model 767/N9. With stop, sewing foot up after thread trimming. = Model 767/N9. With stop, sewing foot down after thread trimming. 4 = With bobbin thread monitor stitch counting (max. 55 stitches)

24 EFKA DAC Supplier Level Code no. with control operation / Code no. with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω t Delay until speed release after start ms A backtack t Sewing foot lift switch-on delay with half ms A heelback t Start delay after disabling the sewing foot ms A lift signal t4 Time of full power of sewing foot lifting ms 6 A 4 t5 Holding power for sewing foot lifting % pa A...% % low holding power % high holding power 5 t6 Thread wiper time ms 55 A**) 6 t7 Delay from end of thread wiper until ms A sewing foot lifting On 7 br Braking effect when modifying the preset value 55 H 4 stages 8 br Braking effect when modifying the preset value H 5 stages tsr Stop time for switching the stitch regulator ms A in the ornamental backtack t Time of full power of backtacking ms 6 A t Holding power for backtacking...% % pa A % low holding power % high holding power 5 Zrv = Last counted forward section in the start A backtack OFF = Last counted forward section in the start backtack ON 6 FLS = Fast disabling of sewing foot lift OFF A = Fast disabling of sewing foot lift ON 9 br Positioning power at stop of the drive 55 A ALF Accelerating power of the drive H dgn Speed gate RPM 99 5 A tgn Speed gate damping period ms 99 H dg Speed gate RPM J**) 4 dgf Speed gate On/Off A 5 FmA Function modules for output A on socket A/ 4 J and input A on socket A/8 active only if parameter 55 is not equal to. = No function = Switch stitch length = Fullness control with speed limitation = Fullness control without speed limitation 4 = Single stitch with stitch length switching 5 = Lift / lower roller 6 = Lift / lower fabric endstop 7 = Second thread tension 8 = Manual edge trimmer 9 = Automatic edge trimmer = Triflex function: affects stitch length, thread tension, speed limitation, automatic backtack and function module for output B (parameter 55 = 7) = High lift for walking foot **) When programming the -digit or 4-digit control parameter values (without control panel), the -digit or -digit value displayed must be multiplied by.

25 7 EFKA DAC5 Supplier Level Code no. with control operation / Code no. with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω = Functions of sewing foot pressure reduction: the following functions are available if the key is enabled: - Pedal Pulsing parameter 4 is effective - Pedal > Pulsing parameter 4 is effective - Pedal + Sewing foot is lowered - Pedal Pulsing parameter 4 is effective - Pedal Pulsing parameter 4 or trimming operation is effective = Handwheel runs in the direction of rotation according to setting of parameter 6 4 = Handwheel runs in the opposite direction of rotation according to setting of parameter 6 5 AFA Output A (A/) and LED A (A/9) after thread A trimming = Output signals are maintained as before thread trimming = Output signals as after power On Function with pa. 5 =,,, 7, 8, 9, 5 Ain Output A (A/) A = Output not inverted = Output inverted 5 ca Number of stitches until enabling of output A 54 H Function with parameter 5 = 5, 9 54 ca_ Number of stitches until disabling of output A 54 H Function with parameter 5 = 9, 55 Fmb Function modules for output B on socket A/ 4 J and input B on socket A/7 active only if parameter 5 is not equal to. = No function = Switch stitch length = Fullness control with speed limitation = Fullness control without speed limitation 4 = Single stitch with stitch length switching 5 = Lift / lower roller 6 = Lift / lower fabric endstop 7 = Second thread tension 8 = Manual edge trimmer 9 = Automatic edge trimmer = Triflex function: affects stitch length, thread tension, speed limitation, automatic backtack and function module for output A (parameter 5 = 7) = High lift for walking foot = Function as with parameter 5 = Handwheel runs in the direction of rotation according to setting of parameter 6 4 = Handwheel runs in the opposite direction of rotation according to setting of parameter 6 56 bfa Output B (A/) and LED B (A/) after thread A trimming = Output signal status is maintained as before thread trimming = Output signal status as after power On Function with pa. 55 =,,, 7, 8, 9,

26 EFKA DAC5 8 Supplier Level Code no. with control operation / Code no. with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω 57 bin Output B (A/) A = Output not inverted = Output inverted 58 cb Number of stitches until enabling of output B 54 H Function with parameter 55 = 5, 9 59 cb_ Number of stitches until disabling of output B 54 H Function with parameter 55 = 9, 6 PLc Time interval which can be varied by means of the A number of stitches performed after sewing foot lowering until roller lowering in the seam On/Off (only if parameter 5 = 5 or 55 = 5). At ouput A stitch setting with parameter 5 At output B stitch setting with parameter 58 = Time interval which can be varied by the number of stitches performed OFF = Time interval which can be varied by the number of stitches performed ON 6 FLk = Lift roller, but without sewing foot lift and H backtack = Lift roller with sewing foot lift and backtack = Lift roller with sewing foot lift = Lift roller with backtack Effective only if parameter 5 or 55 = 5 6 hpt = Roller remains lowered when enabling H high lift for walking foot. = Roller is lifted when enabling high lift for walking foot. Effective only if parameter 5 = and parameter 55 = 5 or if parameter 5 = 5 and parameter 55 =. 6 ihr Handwheel increments carried out when incr. 5 H the key is pressed once (function module A at the input of socket A/8 or function module B at the input of socket A/7) 64 nhr Handwheel speed RPM H**) 65 dhr Delay time until the key is pressed down ms 55 H**) causing the handwheel to rotate continuously (function module A at the input of socket A/8 or function module B at the input of socket A/7). Pressing the key briefly: if preset value of parameter 6. Increments set using parameter 6 are carried out. Keeping the key pressed down: if preset value of parameter 6. Handwheel rotates continuously. 66 LFL = Sewing foot lowers when the handwheel H rotates. = The functions pedal in pos. or automatic sewing foot lift remain effective 67 kfk = The edge trimmer remains On, independently H of sewing foot lifting. = The edge trimmer is disabled when the sewing foot is lifted 69 PSv Positioning shift degrees H **) When programming the -digit or 4-digit control parameter values (without control panel), the -digit or -digit value displayed must be multiplied by.

27 9 EFKA DAC5 Supplier Level Code no. with control operation / Code no. with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω 7 PGm Selection according to the position sensors. 5 H Setting of socket B8 see chapter Connection Diagram = The positions are generated by means of the transmitter incorporated in the motor and can be set using parameter 7. = Setting the sensor to position. Set position using parameter 7, starting from leading edge position. = Setting the sensor to position. Set position using parameter 7, starting from trailing edge position. = Setting the sensor to position. Set position using parameter 7, starting from leading edge position. 4 = Setting the sensor to position. Set position using parameter 7, starting from trailing edge position. 5 = No position sensor available. The drive stops unpositioned. The thread trimmer function is suppressed with this setting. SEN 6 IN POS B8/7 +5V V ST POS ST/ OUT POS ST/ PE PA Pa 7 PE PA 7 = POS ST/ OUT POS ST/ POS ST/ OUT POS ST/ POS ST/ OUT POS ST/ PE PE PE PA Pa 7 PA Pa 7 PA Pa 7 PE PE PE PA PA PA 7 = 4 7 = 7 = = V = high 67/SEN--DA OUT (position window) = npn transistor (emitter to V) is conductive. Width of position window cannot be adjusted!

28 EFKA DAC5 Supplier Level Code no. with control operation / Code no. with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω 7 PGm Selection according to the position sensors. 5 A Setting of socket B8 see chapter Connection Diagram = Function as in table on previous page! = Setting the sensor to position. Set position using parameter 7, starting from trailing edge position. = Setting the sensor to position. Set position using parameter 7, starting from leading edge position. = Setting the sensor to position. Set position using parameter 7, starting from trailing edge position. 4 = Setting the sensor to position. Set position using parameter 7, starting from leading edge position. 5 = No position sensor available. The drive stops unpositioned. The thread trimmer function is suppressed with this setting. SEN 6 IN POS B8/7 +5V V ST POS ST/ OUT POS ST/ PE PA Pa 7 PE PA 7 = POS ST/ OUT POS ST/ POS ST/ OUT POS ST/ POS ST/ OUT POS ST/ PE PE PE PA Pa 7 PE PA Pa 7 PA Pa 7 PE PE PA PA PA 7 = 4 7 = 7 = = V = high 67/SEN--DA OUT (position window) = npn transistor (emitter to V) is conductive. Width of position window cannot be adjusted! Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω 7 trr Transmission ratio between motor shaft and 55 5 H machine shaft (calculation formula see instruction manual!) Attention! The transmission ratio should be determined and indicated as precisely as possible! 8 SEL Display of the select resistor values (socket A/-4) 68 F **) for the following machine series: Ω = 7, 7, 7, 74, 75 Ω = 5 47Ω 68Ω = 69, 67, 68, 69, 48, 48 Ω = 67, 8, 8, 467, 767, 768 **) When programming the -digit or 4-digit control parameter values (without control panel), the -digit or -digit value displayed must be multiplied by.

29 EFKA DAC5 Supplier Level Code no. with control operation / Code no. with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω 8 Pd New sewing start after machine run blockage A = Immediate start = Only with pedal in position (neutral) 8 LoS Functioning of the switch for machine run blockage A = Make contact (N.O.) = Break contact (N.C.) 8 LSP Function machine run blockage B = Function Off = Blockage, without positioning = Blockage, with positioning 84 StP Start and end backtack can be interrupted with A pedal in position (neutral) On/Off 87 dba Speed limitation DB (n) for manual A backtack = Speed limitation Off = Speed limitation On 88 n9 Speed limitation (n9) for manual RPM B **) ornamental backtack 89 n Speed limitation (n) DB RPM C **) 9 8 Select slide-in strip number for the V8 control 8 H panel (illustration see chapter Slide-in Strips for V8/V8 Control Panels ). At setting, keys... are Off. 9 8 Select slide-in strip number for the V8 control H panel (illustration see chapter Slide-in Strips for V8/V8 Control Panels ). At setting, keys...4 are Off. 9 tf Selection of the input function using key (A) C F on the V8/V8 control panel = Key F is Off = Needle up/down = Needle up = Single stitch (basting stitch) 4 = Full stitch 5 = Needle to position 6 = Output A, if parameter 5 > 7 = Output B, if parameter 55 > 8 = Operation in the direction of rotation 9 = Operation in the opposite direction of rotation... = No function = High lift for walking foot with speed limitation n (operational mode not stored) 4 = High lift for walking foot with speed limitation n (operational mode stored) 5 = No function 6 = Intermediate backtack 7 = Backtack suppression / recall 8 = No function 9 = Reset bobbin thread monitor 94 tf Selection of the input function using key (B) 9 C F on the V8/V8 control panel Functions of the key as with parameter 9, except at setting key F is Off 97 tfl Time monitoring of sewing foot lift sec 5 8 A (monitoring off at ) 98 EF- Upper limit (pa. 4) ON period for % A sewing foot lift EV- Upper limit (pa. ) ON period for % A backtacking... **) When programming the -digit or 4-digit control parameter values (without control panel), the -digit or -digit value displayed must be multiplied by.

30 EFKA DAC5 Supplier Level Code no. with control operation / Code no. with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω AA Selectable power transistors for signal A C = No function = Signal on output M = Signal on output M = Signal on output M 4 = Signal on output M4 5 = Signal on output M5 6 = Signal on output M6 7 = Signal on output M7 8 = Signal on output M8 9 = Signal on output M9 = Signal on output M = Signal on output M = Signal on output VR So Issue signal A 4 H = Signal until seam end (according to setting of parameter ) = Signal over time = Signal until seam end and drive stops = Signal during stitch counting (according to setting of parameter 9) 4 = Signal A as puller function tr Starting point for signal A 4 H = Start at the beginning of the seam = Start of the signal triggered by light barrier sensing = Start of the signal when the drive stops at the seam end = Start from light barrier covered onwards at the beginning of the seam 4 = Signal A switchable only manually do Delay of signal A H = No delay until signal On = Delay over time until signal On = Delay over stitches until signal On 4 dt Delay time until signal A On ms 55 C**) 5 St ON period of signal A ms 55 C**) 6 na Speed mode when signal A is On C = Pedal controlled speed = Limited speed n9 = Limited speed n 7 A Signal A On/Off H 8 da Stitches delaying signal A stitches 999 H 9 ca Stitch counting during signal A stitches 999 H AA Selectable power transistors for signal A C = No function = Signal on output M = Signal on output M = Signal on output M 4 = Signal on output M4 5 = Signal on output M5 6 = Signal on output M6 7 = Signal on output M7 8 = Signal on output M8 9 = Signal on output M9 = Signal on output M = Signal on output M = Signal on output VR **) When programming the -digit or 4-digit control parameter values (without control panel), the -digit or -digit value displayed must be multiplied by.

31 EFKA DAC5 Supplier Level Code no. with control operation / Code no. with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω So Issue signal A 4 H = Signal until seam end (according to setting of parameter ) = Signal over time = Signal until seam end and drive stops = Signal during stitch counting (according to setting of parameter 9) 4 = Signal A as puller function tr Starting point for signal A 4 H = Start at the beginning of the seam = Start of the signal triggered by light barrier sensing = Start of the signal when the drive stops at the seam end = Start from light barrier covered onwards at the beginning of the seam 4 = Signal A switchable only manually do Delay of signal A H = No delay until signal On = Delay over time until signal On = Delay over stitches until signal On 4 dt Delay time until signal A On ms 55 C**) 5 St ON period of signal A ms 55 C**) 6 na Speed mode when signal A is On C = Pedal controlled speed = Limited speed n9 = Limited speed n 7 A Signal A On/Off H 8 da Stitches delaying signal A stitches 999 H 9 ca Stitch counting during signal A stitches 999 H bp Switch-off time of signals A and A C = Signals effective until seam end = Signals effective until pedal is in pos. (neutral) Std Suppression of the seam when stitches are set C = Suppression Off = Suppression On dkn = Correction seam Off E = Correction seam On = Interruption of seam or pattern by thread trimmer FLn = Sewing foot is not lifted after power On C = Sewing foot is lifted after power On This function is enabled only if TEACH IN On 4 ti = TEACH IN Off H = TEACH IN On TEACH IN programming is possible only with V8. Execution of pattern is possible without V8. 5 cti Erasing all TEACH IN data H - Input code number after power On - Press the E key - Input parameter 5 - Press the E key - Input - Press the P key - The display briefly shows deleted, and a short acoustic signal is issued - Press the P key - all TEACH IN programs have been erased!

32 EFKA DAC5 4 Supplier Level Code no. with control operation / Code no. with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω Ω 68Ω Ω 6 EPE Disabling the P and E keys on the control panels H and the P key on the control = P and E keys are Off = P key is On and E key is Off = P key is Off and E key is On = P and E keys are On 7 EPm Disabling the + / - keys on the control panels H = + and keys are Off = + and keys are On 8 ob Disabling the E, +, - and >> keys on the control H = E, +, - and >> keys are Off = E, +, - and >> keys are On FLd = The settings of parameters and 4 H determine the sewing foot lift function. = If sewing foot lifting is stored in the seam, the solenoid will be fully activated based on the settings of parameter, and pulsed based on the settings of parameter 4. t4_ Time of full power of sewing foot lifting ms 6 H 4 t5_ Holding power for sewing foot lifting % pa H...% % low holding power % high holding power 4 EEP Immediate storage of all changed data H - Input code number after power On - Press the E key - Input parameter 4 - Press the E key - Set display from to - Press the E or P key - All data are stored 5 Sir Recall of Fast Installation Routine (SIR) H (see description in chapter on page 5!) NA = Seam start LS = Light barrier uncovered or covered at the seam end LS-D = Light barrier uncovered covered (parameter = and parameter = ) NE = Seam end FA-E = End thread trimming operation P= = Pedal in pos. (neutral) St = Stitches Parameter = Signals enabled according to setting of parameter /. Parameter = Signals enabled until pedal is in pos. (neutral). ) Seam end after stitch counting or light barrier sensing ) Seam end after pedal in pos.

33 5 EFKA DAC5 Parameter A A [ms] [ms] 8 8 [St] 9 9 [St] NA LS-D NE FA-E P= ) ) ) ) 56/BILD Parameter A A [ms] [ms] 8 8 [St] 9 9 [St] NA LS NE FA-E P= 56/BILD4 See previous page for explanation of letter symbols!

34 EFKA DAC5 6 7 Error Displays General Information On the control On the V8 On the V8 Signification A InF A InF A Pedal not in neutral position, when turning the machine on A -StoP- blinking -StoP- blinking + Machine run blockage symbol display A InF A InF A Reference position is not set A5 InF A5 InF A5 Emergency run, identification of an invalid machine select Programming Functions and Values (Parameters) On the control On the V8 On the V8 Signification Returns to Returns to Like V8 + Wrong code number or parameter number or to last or to last display InF F input parameter number parameter number Serious Condition On the control On the V8 On the V8 Signification E InF E InF E The external pulse encoder e.g. IPG... is defective or not connected. E InF E InF E Line voltage too low, or time between power off and power on too short. E InF E InF E Machine blocked or does not reach the desired speed. E4 InF E4 InF E4 Control disturbed by deficient grounding or loose contact. E9 InF E9 InF E9 EEPROM defective. Hardware Disturbance On the control On the V8 On the V8 Signification H InF H InF H Commutation transmitter cord or frequency converter disturbed. H InF H InF H Processor disturbed

35 7 EFKA DAC5 8 Slide-in Strips for V8/V8 Control Panels Slide-in strips for the V8 control panel Slide-in strips for the V8 control panel R F R F F F R F R F F F 4 R F F 5 F INSERT F DELETE F 6 7 F F F INSERT F DELETE F 8 F INSERT F DELETE F 9 F INSERT F DELETE F KL56e Note When changing the setting of parameters 9 / 9, the V8 / V8 functions change as well, save function keys F / F which are influenced by parameters 9 /94.

36 FRANKL & KIRCHNER GMBH & CO KG SCHEFFELSTRASSE 7 D-687 SCHWETZINGEN TEL.: TELEFAX: info@efka.net OF AMERICA INC. 75 NORTHCREST ROAD SUITE ATLANTA GEORGIA 4 PHONE: (77) TELEFAX: (77) efkaus@efka.net ELECTRONIC MOTORS SINGAPORE PTE. LTD. 67, AYER RAJAH CRESCENT 5- SINGAPORE 995 PHONE: TELEFAX: efkaems@efka.net 5(8)-84 J (465 EN)

CONTROL DA82GA3312 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS. with control panel V810/V820

CONTROL DA82GA3312 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS. with control panel V810/V820 CONTROL DA82GA332 with control panel V8/V82 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS No. 42276 English FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS GMBH & CO KG SINGAPORE

More information

CONTROL DA82GA3316 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS. with control panel V810/V820

CONTROL DA82GA3316 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS. with control panel V810/V820 CONTROL DA82GA336 with control panel V8/V82 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS No. 4236 English FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS GMBH & CO KG SINGAPORE PTE.

More information

FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA SINGAPORE PTE. LTD.

FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA SINGAPORE PTE. LTD. - YA620A5080 CONTROL YA620A 5080 Operating manual With parameter list - Putting into Service - Settings - Functional Description - Connection Diagrams - Timing Diagrams No. 402454 English FRANKL & KIRCHNER

More information

FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS

FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS dc5xx CONTROL dc5 ABA5 ABA5 dc55 ABA5 ABA5 LIST OF PARAMETERS No. 8 English FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS GMBH & CO KG SINGAPORE PTE. LTD. EFKA ABA/ABA + ABA/ABA (PL) CONTENTS

More information

AB286A5400 KL2341 INSTRUCTION MANUAL FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS

AB286A5400 KL2341 INSTRUCTION MANUAL FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS CONTROL AB286A5400 AB286A5400 KL2341 INSTRUCTION MANUAL No. 402280 English FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS GMBH & CO KG SINGAPORE PTE. LTD. 3 EFKA AB286A5400 CONTENTS Page

More information

Part 1: Operating Instructions Cl. 271 to 274

Part 1: Operating Instructions Cl. 271 to 274 Contents Page: Preface and General Safety Notes Part 1: Operating Instructions Cl. 271 to 274 1. Product Description 1.1 Short Description and Proper Use..................... 5 1.2 Technical Data................................

More information

Part 1: Operating Instructions Cl

Part 1: Operating Instructions Cl Contents Page: Preface and General Safety Information Part 1: Operating Instructions Cl. 381-382 1. Product Description........................... 5 2. Proper Use................................. 5 3.

More information

FBX-PA-2AC. Third edition : April No

FBX-PA-2AC. Third edition : April No FBX-PA-2AC Third edition : April 2006 No. 060058 INTRODUCTION Thank you very much for purchasing Kansai Special FBX series. Read and study this Instruction Manual carefully before you start any of the

More information

DAC basic/classic Instructions for use. Software version: B03.0 or later

DAC basic/classic Instructions for use. Software version: B03.0 or later DAC basic/classic Instructions for use Software version: B03.0 or later IMPORTANT READ CAREFULLY BEFORE USE KEEP FOR FUTURE REFERENCE All rights reserved. Property of Dürkopp Adler AG and protected by

More information

Part 3: Service Instructions Cl

Part 3: Service Instructions Cl Contents Page: Part 3: Service Instructions Cl. 550--. General................................................. 3. Setting the Machine Head...................................... 4. Arm Shaft Crank............................................

More information

USER S MANUAL. KM-2070P SERIES Electronically Controlled 1-Needle ZigZag Lock Stitch Machine Electronic Control Part

USER S MANUAL. KM-2070P SERIES Electronically Controlled 1-Needle ZigZag Lock Stitch Machine Electronic Control Part USE S MANUAL KM-2070P SEIES Electronically Controlled 1-Needle ZigZag Lock Stitch Machine Electronic Control Part Best Quality Best Price Best Service 1. Thank you for purchasing our product. Based on

More information

PicoDrive P45 PD2-L EcoDrive P74 ED-L

PicoDrive P45 PD2-L EcoDrive P74 ED-L Industrial PicoDrive P45 PD2-L EcoDrive P74 ED-L INSTRUCTION MANUAL This Instruction Manual is valid for drives from the following software version on: P45 PD2-L # 4_045_05 P74 ED-L # 1_074_08 296-12-19

More information

Basic steps to time the Gammill quilting machine s rotary sewing hook

Basic steps to time the Gammill quilting machine s rotary sewing hook Basic steps to time the Gammill quilting machine s rotary sewing hook 1.) Turn the machine off and unplug it. 2.) With the needle bar in the raised position, remove the bobbin and bobbin case. 3.) Remove

More information

LS2-B891 LT2-B892 LS2-B891-05, LT2-B892-05

LS2-B891 LT2-B892 LS2-B891-05, LT2-B892-05 LS2-B891 LT2-B892 Single Needle Unison Feed Lock Stitcher Single Needle Unison Feed Lock Stitcher with Thread Trimmer Twin Needle Unison Feed Lock Stitcher Twin Needle Unison Feed Lock Stitcher with Thread

More information

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection Quick Start Guide TECO F510 Inverter This guide is to assist you in installing and running the inverter and verify that it is functioning correctly for it s main and basic features. For detailed information

More information

CONTENTS PRECAUTIONS BEFORE STARTING OPERATION PREPARATION FOR OPERATION CAUTIONS ON USE OPERATION

CONTENTS PRECAUTIONS BEFORE STARTING OPERATION PREPARATION FOR OPERATION CAUTIONS ON USE OPERATION CONTENTS PRECAUTIONS BEFORE STARTING OPERATION ------------------------------------- 1 PREPARATION FOR OPERATION 1. Adjustment of needle bar stop position ---------------------------------------------------------

More information

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , , maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers 249630, 249631, 249632, 318305, 381510 September 2009 edition The DEC (Digital EC Controller) is a 1-quadrant amplifier for controlling electronically

More information

STEPPING MOTOR EMULATION

STEPPING MOTOR EMULATION OPERATING MANUAL SERIES SMTBD1 OPTIONAL FUNCTIONS (Version 2.0) European version 2.0 STEPPING MOTOR EMULATION OPTION C This manual describes the option "C" of the SMT-BD1 amplifier: Stepping motor emulation.

More information

The Allen-Bradley Servo Interface Module (Cat. No SF1) when used with the Micro Controller (Cat. No UC1) can control single axis

The Allen-Bradley Servo Interface Module (Cat. No SF1) when used with the Micro Controller (Cat. No UC1) can control single axis Table of Contents The Allen-Bradley Servo Interface Module (Cat. No. 1771-SF1) when used with the Micro Controller (Cat. No. 1771-UC1) can control single axis positioning systems such as found in machine

More information

SERVICE MANUAL PARTS LIST MODEL: NH40

SERVICE MANUAL PARTS LIST MODEL: NH40 SERVICE MANUAL & PARTS LIST MODEL: NH40 CONTENTS What to do when... 1-3 SERVICE ACCESS Face Cover... 4 Bed Cover... 5 Free-arm Cover... 6 Front Cover... 7 Rear Cover... 8 MECHANICAL ADJUSTMENT Presser

More information

Select datum Page backward in. parameter list

Select datum Page backward in. parameter list HEIDENHAIN Working with the measured value display unit ND Actual value and input display (7-segment LED, 9 decades and sign) Select datum Page backward in parameter list Confirm entry value Set display

More information

High-speed, 1-needle, Cylinder-bed, Needle-feed, Lockstitch Machine with Large Hook

High-speed, 1-needle, Cylinder-bed, Needle-feed, Lockstitch Machine with Large Hook R High-speed, 1-needle, Cylinder-bed, Needle-feed, Lockstitch Machine with Large Hook DLN-6390 High-speed, 1-needle, Cylinder-bed, Needle-feed, Lockstitch Machine with Automatic Thread Trimmer and Large

More information

Spezialnähmaschine. Betriebsanleitung. Instruction manual. Manuel d'instructions

Spezialnähmaschine. Betriebsanleitung. Instruction manual. Manuel d'instructions 767 Spezialnähmaschine Betriebsanleitung Instruction manual Manuel d'instructions D GB F Postfach 17 03 51, D-33703 Bielefeld Potsdamer Straße 190, D-33719 Bielefeld Telefon +49 (0) 5 21 / 9 25-00 Telefax

More information

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors Servo Amplifier -Quadrant PWM for Brushless DC-Servomotors Series BLD 010 Operating Instructions Index Chapter 1. Description 2. Illustration 3. Specification. Dimensions. Safety notes.1 Skilled personnel.2

More information

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16 MZ Servomotor for butterfly valves VF, VFH delta-elektrogas.com EE157-01/16 MZ Servomotor Contents Description.... 2 Features........ 2 Functioning and application..... 3 Technical specifications......

More information

MTY (81)

MTY (81) This manual describes the option "e" of the SMT-BD1 amplifier: Master/slave tension control application. The general information about the digital amplifier commissioning are described in the standard

More information

M PREMIUM. Additional Instructions. Neat seam beginning (NSB)

M PREMIUM. Additional Instructions. Neat seam beginning (NSB) 867 867-M PREMIUM Additional Instructions Neat seam beginning (NSB) IMPORTANT READ CAREFULLY BEFORE USE KEEP FOR FUTURE REFERENCE All rights reserved. Property of Dürkopp Adler AG and protected by copyright.

More information

Solid-State Digital Counter H7AN

Solid-State Digital Counter H7AN Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or

More information

Revolutionary / 96

Revolutionary / 96 Industrial 2595/96 Revolutionary... The combination of revolutionary design and innovative engineering has led to the development of something quite special, extraordinary something, which will influence

More information

USER MANUAL Version: 1.1

USER MANUAL Version: 1.1 AE-LIFT MOTOR DRIVER USER MANUAL Version: 1.1 Index SECTION 1-WARNINGS...1 SECTION 2-TECHNICAL SPECIFICATIONS...2 2.1 ELECTRICAL SPECIFICATIONS...2 2.2 MECHANICAL SPECIFICATIONS...3 SECTION 3-TECHNICAL

More information

Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED,

Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED, HEIDENHAIN Working with the measured value display unit ND 261 Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED, Page backward in 9 decades

More information

S-85SCH

S-85SCH 4411-4423-4432-4443-4452 5511-5523-5532-5554 44S-85SCH Service Manual 104 73 14-26 2014-02-24 CONTENTS 1. Names of principal parts...2 2. Removing methods of external parts 2-1 Sewing table...3 2-2 Face

More information

BECS-C19. ( For Chenille/Looping Embroidery) OWNER S MANUAL.

BECS-C19. ( For Chenille/Looping Embroidery) OWNER S MANUAL. BECS-C19 ( For Chenille/Looping Embroidery) Version:2012-01 OWNER S MANUAL www.butterflyemb.com Index Index 1 Introduction Of Functions... 1 2 Shift Between Looping Head & Lockstitch Head... 1 2.1 Shift

More information

MAIN PARTS

MAIN PARTS MAIN PARTS 7 8 9 10 11 12 13 1 2 3 17 4 5 6 01 02 03 04 05 12 23 34 45 56 13 24 35 46 57 14 25 36 47 58 15 16 26 27 37 38 48 49 59 60 06 07 08 09 10 17 18 28 29 39 40 50 51 61 62 19 30 41 52 63 20 21 31

More information

Logosol Intelligent Hall-Servo Drive LS-173U Doc # / Rev. C, 02/12/2008

Logosol Intelligent Hall-Servo Drive LS-173U Doc # / Rev. C, 02/12/2008 Features Specially designed for control of brushless motors without encoder Hall-Servo and Encoder-Servo control modes Motors supported: - Brushless 60/120 commutated (AC) - Brush-commutated (DC) Up to

More information

FBX1104P FBX1104 FBX1106P FBX1106

FBX1104P FBX1104 FBX1106P FBX1106 FBX1104P FBX1104 FBX1106P FBX1106 Second edition : September 2004 No. 040037 INTRODUCTION Thank you for your purchasing Kansai Special's FBX Series. Read and study this instruction manual carefully before

More information

WX8800 WX8700 LX5801 WX8842 WX MC30

WX8800 WX8700 LX5801 WX8842 WX MC30 WX8800 WX8700 LX5801 WX8842 WX8842-1 MC30 First published : August 1991 Third edition : August 2004 No. 040037 INTRODUCTION Thank you for your purchasing Kansai Special's WX Series. Read and study this

More information

DLN ENGINEER S MANUAL

DLN ENGINEER S MANUAL High-speed, 1-needle, Cylinder-bed, Needle-feed, Lockstitch Machine with Large Hook DLN-6390 High-speed, 1-needle, Cylinder-bed, Needle-feed, Lockstitch Machine with Automatic Thread Trimmer and Large

More information

Copyright / Trademarks -This manual and its contents are copyrighted. -You may not copy this manual,in whole or part,without written consent of

Copyright / Trademarks -This manual and its contents are copyrighted. -You may not copy this manual,in whole or part,without written consent of Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure

More information

Tarocco Closed Loop Motor Controller

Tarocco Closed Loop Motor Controller Contents Safety Information... 3 Overview... 4 Features... 4 SoC for Closed Loop Control... 4 Gate Driver... 5 MOSFETs in H Bridge Configuration... 5 Device Characteristics... 6 Installation... 7 Motor

More information

LZ-2290A-SR / IP-100D / SC-916

LZ-2290A-SR / IP-100D / SC-916 R Computer-controlled, Direct-drive, High-speed, -needle, Lockstitch, Zigzag Stitching Machine (Quick-reverse type) LZ-90A-SR / IP-00D / SC-96 INSTRUCTION MANUAL NOTE : Read safety instructions carefully

More information

MTY (81)

MTY (81) This manual describes the option "d" of the SMT-BD1 amplifier: Master/slave electronic gearing. The general information about the digital amplifier commissioning are described in the standard SMT-BD1 manual.

More information

STOP! READ THIS FIRST

STOP! READ THIS FIRST STOP! READ THIS FIRST 1 Getting Started With Your Meistergram Embroidery System (the quick guide) Thank you for choosing Pantograms for your embroidery system provider. We encourage you to read the following

More information

Industrial 3721/3741/3745. Documented Quality - Stitch by Stitch

Industrial 3721/3741/3745. Documented Quality - Stitch by Stitch Industrial 3721/3741/3745 Documented Quality - Stitch by Stitch Documented quality The POWERLINE 3721, 3741 and 3745 are quality assurance systems designed for use on safety relevant seams. The PFAFF docu-sewing

More information

USER S MANUAL Operating Manual SB Series Multi-Heads E-Series DM Series K Series

USER S MANUAL Operating Manual SB Series Multi-Heads E-Series DM Series K Series USER S MANUAL Operating Manual SB Series Multi-Heads E-Series DM Series K Series 1. THIS IS AN INSTRUCTION FOR SAFE USE OF AUTOMATIC EMBROIDERY MACHINES. READ THOROUGHLY BEFORE USE. 2. CONTENTS IN THIS

More information

Absolute encoders - SSI

Absolute encoders - SSI with through hollow shaft Features Encoder multiturn / SSI Optical sensing method Resolution: singleturn 14 bit, multiturn 12 bit Compact design Cost-efficient mounting High reliability by self-diagnostics

More information

Daily Maintenance. 2. Insert bobbin cases in to rotary hooks. Make sure bobbin thread is not over 2 inches long. Close bobbin case covers.

Daily Maintenance. 2. Insert bobbin cases in to rotary hooks. Make sure bobbin thread is not over 2 inches long. Close bobbin case covers. Rotary hook 1. Open bobbin case covers and remove bobbin cases. Use brush to remove lint build up in and around rotary hooks. Compressed air may also be used. Daily Maintenance Cle aning Oiling Rotary

More information

User Manual March 2008

User Manual March 2008 User Manual March 008 Motor Silent Gliss 900, 90, 90, 903 Motor Silent Gliss 9030, 903, 903, 9033 Usermanual Motors 90x_903x Page Copyright April 007 by Silent Gliss International Ltd., 3073 Gümligen/Berne

More information

3Specifications CHAPTER THREE IN THIS CHAPTER

3Specifications CHAPTER THREE IN THIS CHAPTER CHAPTER THREE 3Specifications IN THIS CHAPTER Drive Specifications SM and NeoMetric Motor Specifications SM and NeoMetric Motor / Curves SM and NeoMetric Motor Dimensions SM and NeoMetric Encoder Specifications

More information

the needle, the user must take sufficient care to avoid injury and observe the sewing area continuously while sewing.

the needle, the user must take sufficient care to avoid injury and observe the sewing area continuously while sewing. / - nstruct0fl maflua 7 the needle, the user must take the light bulb is 15 watts. agent. by anyone but an authorized Pfaff D) The drive belt must never be adjusted B) When leaving the machine, chan C)

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

Jet Central Sequencer Plus

Jet Central Sequencer Plus Jet Central Sequencer Plus Features The Jet Central Sequencer Plus is a multipurpose electronic device, the capabilities of the unit include: Three part sequencer, operating landing gear and two independent

More information

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442 October 2017 RSTI-EP Slice I/O Specialty Modules EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442 Module Status LED Channel Status LED GE provides several RSTi-EP specialty modules, which

More information

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces: Replaces: 09.12 Electro-hydraulic Control Digital Proportional Amplifier Type: RT-VSPA2-50 Series: 3X Table of contents Contents Page Features 1 Ordering code 2 Functional description 2 Block circuit diagram

More information

DeviceCraft Revision #1 11/29/2010

DeviceCraft Revision #1 11/29/2010 DeviceCraft Revision #1 11/29/2010 DC Wiper Motor H-Bridge Servo / Speed Controller P/N 1020 Features: Dip Switch selectable mode of operation Both PID servo or speed controller Forward/Reverse operation

More information

Valve amplifier for proportional pressure valves

Valve amplifier for proportional pressure valves Valve amplifier for proportional pressure valves Type VT-MRMA1-1 RE 30214 Edition: 2017-03 Replaces: 04.13 Component series 1X Analog, modular design Suitable for controlling a direct current motor-operated

More information

3400HD Series TECHNICAL MANUAL X-3400HD DTI-3400HD D-3400HD. 3400HD Unwind (using 3400ce Circuit Board) Montalvo. Unwind Tension Controllers

3400HD Series TECHNICAL MANUAL X-3400HD DTI-3400HD D-3400HD. 3400HD Unwind (using 3400ce Circuit Board) Montalvo. Unwind Tension Controllers X-34HD DTI-34HD X-34ce (Circuit Board Version) DTI-34ce (Circuit Board Version) D-34HD D-34ce (Circuit Board Version) 34HD Unwind (using 34ce Circuit Board) PID Web Tension Controller Version 1. / Pub.

More information

PM50. Technical Data TECHNOSOFT. DSP Motion Solutions. Power Module for DC, Brushless DC and AC Motors. Version 3.0. PM50 v3.0.

PM50. Technical Data TECHNOSOFT. DSP Motion Solutions. Power Module for DC, Brushless DC and AC Motors. Version 3.0. PM50 v3.0. Version 3.0 PM50 TECHNOSOFT DSP Motion Solutions Power Module for DC, Brushless DC and AC Motors Technical Data Technosoft 2001 Technosoft 2001 1-1 PM50 v3.0 Technical Data TECHNOSOFT DSP Motion Solutions

More information

Instruction manual. Printed: Czech Republic

Instruction manual. Printed: Czech Republic Instruction manual 524 Minerva Boskovice, a.s., Sokolská 60, CZ - 680 17 Boskovice Tel.: +420-516-453434, 453433, 494111 Fax: +420-516-452165 http://www.minerva-boskovice.com Edition : 01/2004 Printed:

More information

SERVICE MANUAL MODEL: 13512, 14412, 15312

SERVICE MANUAL MODEL: 13512, 14412, 15312 SERVICE MANUAL MODEL: 13512, 14412, 15312 CONTENTS TROUBLESHOOTING... 1-3 SERVICE ACCESS (1) FACE COVER, BELT COVER... 4 SERVICE ACCESS (2) BASE PLATE... 5 SERVICE ACCESS (3) FRONT COVER... 6 SERVICE ACCESS

More information

Contents. I'DANGER - To reduce the risk of "SAVE THESE INSTRUCTIONS" This knitting machine is for home use. IIIMPORTANT SAFETY INSTRUCTIONS"

Contents. I'DANGER - To reduce the risk of SAVE THESE INSTRUCTIONS This knitting machine is for home use. IIIMPORTANT SAFETY INSTRUCTIONS Contents Names of Parts 1 How to Assemble the Motor Driving Unit 3 Function of Each Part 12 1. Name of Part 12 2. Explanation of Each Part 12 Operation Step 18 Warn ing 19 When you use Double bed colour

More information

Blue Point Engineering

Blue Point Engineering Blue Point Engineering Instruction I www.bpesolutions.com Pointing the Way to Solutions! Animatronic Wizard - 3 Board (BPE No. WAC-0030) Version 3.0 2009 Controller Page 1 The Wizard 3 Board will record

More information

Awning control system GFM001. Installation and Operating Instructions

Awning control system GFM001. Installation and Operating Instructions Geiger-Funk Sunshade controls Awning control system for 230V drives GFM001 Installation and Operating Instructions for pre-coded systems Table of Contents 1 Introduction...3 2 Safety instructions...3 3

More information

HQ Hideaway. Installation and Operation Version 2.2, April 2015 Part # QT40100

HQ Hideaway. Installation and Operation Version 2.2, April 2015 Part # QT40100 HQ Hideaway Installation and Operation Version 2.2, April 2015 Part # QT40100 Copyright 2015 Handi Quilter, Inc. All rights reserved. Printed in the U.S.A. Table of Contents Page Overview 3 To install

More information

TIPS & TROUBLESHOOTING

TIPS & TROUBLESHOOTING Achieving good stitch quality 5450 North W Street Pensacola FL 32505 850-433-1414 www.martellinotions.com TIPS & TROUBLESHOOTING Understanding how your long arm machine makes a stitch will help you make

More information

OPC-E1-PG3 Specifications

OPC-E1-PG3 Specifications OPC-E1-PG3 Specifications Power Electronics Business Group Drive Division Development Dept. b DATE NAME APPROVE a DRAWN 2006-06-05 O. Mizuno CHECKED 2006-06-06 T. Ichihara K. Fujita Fuji Electric Co.,

More information

KWIKFOLD User Manual

KWIKFOLD User Manual KWIKFOLD User Manual English X2 1 2 3 4 5 7 X1 Ernst Nagel GmbH: Gebrauchsanleitung 2002-06-13 eng.doc 2/16 Introduction Your Foldnak 40 bookletmaker uses the Foldnak principle: stapling and folding in

More information

Lockstitch machine with automatic thread trimmer J-150QVP INSTRUCTION MANUAL EN IMPORTANT: Read all safety regulations carefully and understand them before using your sewing machine. Retain this instruction

More information

Replacing the Reciprocator on the SWF Compact Series Machine (601C and 1201C)

Replacing the Reciprocator on the SWF Compact Series Machine (601C and 1201C) Follow the instructions below to replace the reciprocator in the SWF Compact series machines. The tools required can be found in the tool kit that came with the machine. Preparation 1. First, place the

More information

Mx-D15 Intelligent Valve Actuator

Mx-D15 Intelligent Valve Actuator Application Small radio controlled, battery-powered actuator for room temperature control. For thermostat valve bodies for direct mounting on commercially available radiator valves for room-specific temperature

More information

Rotational speed controller

Rotational speed controller Model number Features Rotational speed monitoring up to khz pre-select value with relay output and LED indicator Multi-range power pack -, -, -wire and NAMUR sensors as well as rotary encoder connectable

More information

EIB/KNX Switch Actuators. User manual

EIB/KNX Switch Actuators. User manual EIB/KNX Switch Actuators User manual IT KNT 004 IT KNT 012 Tel.: +34943627988 E-mail: knx@dinuy.com Web: www.dinuy.com Contents 1. Introduction --------------------------------------------------------------------------------------------------------------

More information

SERVICE MANUAL AND PARTSLIST

SERVICE MANUAL AND PARTSLIST SERVICE MANUAL AND PARTSLIST Next 20 CONTENTS WHAT TO DO WHEN... 1~3 SERVICE ACCESS FACE COVER... 4 TOP COVER... 4 BASE COVER... 5 REAR COVER... 6 FRONT COVER... 7 MECHANICAL ADJUSTMENT NEEDLE THREAD TENSION...

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS GB OPERATING INSTRUCTIONS Automatic Wedge Welding Machine Please read operating instructions carefully before use and keep for further reference. APPLICATION The is an automatic wedge welding machine for

More information

+GF+ SIGNET Temperature Transmitter Instructions

+GF+ SIGNET Temperature Transmitter Instructions GF SIGNET 80- Temperature Transmitter Instructions ENGLISH -80.090- B-/00 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal

More information

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders 18 bit ST / 12 bit MT

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders 18 bit ST / 12 bit MT Features High resolution encoder multiturn / SSI Optical sensing method Resolution: singleturn 18 bit, multiturn 12 bit Electronic setting of zero point Counting direction input Available with additional

More information

Instruction manual. Printed: Czech Republic

Instruction manual. Printed: Czech Republic Instruction manual 525 Minerva Boskovice, a.s., Sokolská 60, CZ - 680 17 Boskovice Tel.: +420-516-453434, 453433, 494111 Fax: +420-516-452165 http://www.minerva-boskovice.com Edition : 01/2004 Printed:

More information

S D 1 Operating Instructions

S D 1 Operating Instructions S D 1 Operating Instructions Volutronic 1. SAFETY 3 2. DESCRIPTION 4 3. CONNECTING THE SD1 5 3.1 Connecting the voltage supply 5 3.2 Connecting SD1 with rectangular output. 5 3.3 Connecting the SD1 with

More information

MDC VAC Input Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA

MDC VAC Input Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA MDC200-048051 110VAC Input Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

First published : May 1997 Fourth edition : January No

First published : May 1997 Fourth edition : January No First published : May 1997 Fourth edition : January 2006 No. 050153 INTRODUCTION Thank you for your purchasing Kansai Special's FX Series. Read and study this instruction manual carefully before beginning

More information

Direct Drive Programmable electronic pattern sewer with cylinder bed

Direct Drive Programmable electronic pattern sewer with cylinder bed Direct Drive Programmable electronic pattern sewer with cylinder bed BAS-342G 300 200mm Beautiful pattern stitching, faithful to sewing data Max. sewing speed of 2,700 rpm (with stitch length 3.5 mm) Strong

More information

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS Digital Thermometer 23 88 350 mm 3 kg (8-5/8 3-/2 3-3/4" 6.6 lbs) The Digital Thermometer has 6 ranges of temperature sensors and measuring functions of DC V and Ω. YOKOGAWA-original A/D converter (feedback

More information

KE-430FX KE-430FS BE-438FX

KE-430FX KE-430FS BE-438FX KE-430FX KE-430FS BE-438FX Basic Operation Manual ELECTRONIC DIRECT DRIVE LOCKSTITCH BAR TACKER ELECTRONIC DIRECT DRIVE LOCKSTITCH BUTTON SEWER Please read this manual before using the machine. Please

More information

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany Technical manual Microstep driver NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D-85652 Landsham near Munich, Germany Tel. +49 (0)89-900 686-0 Fax +49 (0)89-900 686-50 info@nanotec.de Editorial Editorial

More information

Parallel. Parallel. data transmission. Technical Information TR - ECE - TI - GB /05/2016

Parallel. Parallel. data transmission. Technical Information TR - ECE - TI - GB /05/2016 TR - ECE - TI - GB - 0054-01 04/05/2016 Parallel Parallel data transmission Technical Information TR-Electronic GmbH D-78647 Trossingen Eglishalde 6 Tel.: (0049) 07425/228-0 Fax: (0049) 07425/228-33 email:

More information

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC Datasheet NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO 13849-1 EN 62061 EN 81-1 EN 50156-1 Approvals NSD-3580 24 VDC NSD-3590 115 TO 230 VAC Technical

More information

KE 436 B Electronic Lockstitch Pattern Tacker with Stepping Foot and Programming function

KE 436 B Electronic Lockstitch Pattern Tacker with Stepping Foot and Programming function KE 436 B Electronic Lockstitch Pattern Tacker with Stepping Foot and Programming function Specifications Stitch formation Maximum sewing speed Maximum pattern size (X x Y) Feed mechanism Stitch length

More information

For more information on these functions and others please refer to the PRONET-E User s Manual.

For more information on these functions and others please refer to the PRONET-E User s Manual. PRONET-E Quick Start Guide PRONET-E Quick Start Guide BASIC FUNCTIONS This guide will familiarize the user with the basic functions of the PRONET-E Servo Drive and assist with start up. The descriptions

More information

LS7362 BRUSHLESS DC MOTOR COMMUTATOR / CONTROLLER

LS7362 BRUSHLESS DC MOTOR COMMUTATOR / CONTROLLER LS7362 BRUSHLESS DC MOTOR COMMUTATOR / CONTROLLER FEATURES: Speed control by Pulse Width Modulating (PWM) only the low-side drivers reduces switching losses in level converter circuitry for high voltage

More information

Dream Fabric Frame Assembly Instructions

Dream Fabric Frame Assembly Instructions Dream Fabric Frame Assembly Instructions Copyright January 1, 2016 Jim M. Bagley, GraceWood, Inc (Reproduction Prohibited) Version 2.4 Table Of Contents Parts List 3 Step 1: Table Set Up 6 Step 2: Install

More information

Incremental encoders 6

Incremental encoders 6 Incremental encoders ELECTRONIC GmbH Incremental encoders 6 6.1 Explanatory notes...6-3 6.2 Functional description...6-4 6.3 Applications...6-5 6.4 Assembly examples...6-6 6.5 Alternative designs...6-8

More information

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT Features Encoder multiturn / SSI Optical sensing method Resolution: max. singleturn 14 bit, multiturn 16 bit Clamping or synchro flange Electronic setting of zero point Counting direction input Available

More information

888 Service Instructions

888 Service Instructions 888 Service Instructions All rights reserved. Property of Dürkopp Adler AG and copyrighted. Reproduction or publication of the content in any manner, even in extracts, without prior written permission

More information

the single-needle high-speed seamer, POWERLINE 2235, with triple feed (bottom, needle and alternating top feed) and horizontal hook

the single-needle high-speed seamer, POWERLINE 2235, with triple feed (bottom, needle and alternating top feed) and horizontal hook Industrial 02 // 03 Philosophy Philosophy The fine tension of the surface signalizes power and dynamics, the design combines traditional forms with ergonomic elegance. During the development of the single-needle

More information

8-Bit A/D Converter AD673 REV. A FUNCTIONAL BLOCK DIAGRAM

8-Bit A/D Converter AD673 REV. A FUNCTIONAL BLOCK DIAGRAM a FEATURES Complete 8-Bit A/D Converter with Reference, Clock and Comparator 30 s Maximum Conversion Time Full 8- or 16-Bit Microprocessor Bus Interface Unipolar and Bipolar Inputs No Missing Codes Over

More information

LSI/CSI LS7560N LS7561N BRUSHLESS DC MOTOR CONTROLLER

LSI/CSI LS7560N LS7561N BRUSHLESS DC MOTOR CONTROLLER LSI/CSI LS7560N LS7561N LSI Computer Systems, Inc. 15 Walt Whitman Road, Melville, NY 747 (631) 71-0400 FAX (631) 71-0405 UL A3800 BRUSHLESS DC MOTOR CONTROLLER April 01 FEATURES Open loop motor control

More information

Happy Link Software INSTRUCTION MANUAL

Happy Link Software INSTRUCTION MANUAL Happy Link Software INSTRUCTION MANUAL 101001E-3 HAPPY Contents Regarding this software Normal Operation -------------------------------------------------------------------------------------------------

More information

1 SAFETY INSTALLATION OPERATION COMPONENTS FAULT DIAGNOSTICS FUNCTIONS TECHNICAL SPECIFICATIONS...

1 SAFETY INSTALLATION OPERATION COMPONENTS FAULT DIAGNOSTICS FUNCTIONS TECHNICAL SPECIFICATIONS... 1 SAFETY... 2 1.1 Troubleshooting... 2 1.2 The microwave oven warnings... 2 1.3 Inverter circuit warnings... 2 1.4 Leak test (leak measurement)... 3 2 INSTALLATION... 4 3 OPERATION... 4 4 COMPONENTS...

More information

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES Digital Thermometer High-Accuracy Reference Junction Compensation: Compensation accuracy (±0.2 C) Input terminals are provided on both front and rear panels, and an input site is switch selectable. The

More information

Actuator ICAD 600A / ICAD 600A-TS / ICAD 1200A

Actuator ICAD 600A / ICAD 600A-TS / ICAD 1200A Installation Guide Actuator ICAD 600A / ICAD 600A-TS / ICAD 1200A 027R9966 ICAD 600A ICAD 600A-TS ICAD 1200A 027R9966 ICAD 600A / ICAD 600A-TS ICAD 1200A Fig. 1 Fig. 2 Note: When mounting the ICAD make

More information