CONTROL DA82GA3316 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS. with control panel V810/V820

Size: px
Start display at page:

Download "CONTROL DA82GA3316 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS. with control panel V810/V820"

Transcription

1 CONTROL DA82GA336 with control panel V8/V82 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS No English FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS GMBH & CO KG SINGAPORE PTE. LTD.

2

3 3 EFKA DA82GA336 (PL) CONTENTS Page Putting into Service 5 2 Socket Connectors 5 2. Position in the Control Connection Diagram 6 3 Timing Diagrams 9 4 List of Parameters 2 4. Operator Level Technician Level Code no. 97 with control panel operation Supplier Level Code no. 36 with control panel operation 29 5 Error Displays 32 6 Slide-in Strips for the V8 Control Panel 33

4

5 5 EFKA DA82GA336 (PL) Putting into Service Before putting the control into service, the following must be ensured, checked and/or adjusted:! The correct installation of the drive, position transmitter and accompanying devices, if necessary! The correct adjustment of the direction of motor rotation using parameter 6! The machine select, which can be verified using parameter 28! If necessary, the setting of the reference position using parameter 7! If necessary, the setting of the positions using parameter 7! If necessary, the correct positioning speed using parameter! If necessary, the correct maximum speed compatible with the sewing machine using parameter! If necessary, the setting of the remaining relevant parameters! Start sewing in order to save the set values See instruction manual for details! 2 Socket Connectors 2. Position in the Control B Position transmitter B2 Commutation transmitter for d.c. motor A (ST2) Inputs and outputs B (B4) Inputs and outputs C (B5) Inputs and outputs D (B3) Keys and light emitting diodes B8 Light barrier module / interface B8 Actuator B776 Control panel Variocontrol (as shown: 9/25-pin adapter plugged in) *) Type designation

6 EFKA DA82GA336 (PL) Connection Diagram ATTENTION! When connecting the outputs, ensure that a total power of 96VA constant load will not be exceeded! DB2 - Speed limitation 2 RPM ML - Motor running DB3 - Speed limitation 3 RPM NFD - Sewing foot pressure FA - Thread trimmer NHT - Needle up/down FAWU-L - Thread monitor bottom left NK/US - Needle cooling / option FAWU-R - Thread monitor bottom right R-N-HP - Setpoint potentiometer for FK - Thread clamp speed limitation depending on high lift FL - Sewing foot lift R-SELEKT - Resistor for machine select FSPL - Thread tension release STK - Switch stitch length FSPR - Thread tension reduction VR - Backtacking FW - Thread wiper VRU - Backtack suppression / recall HP - High lift limitation WALZ - Roller feed LS - Light barrier ZVR - Intermediate backtack LSP - Machine run blockage ) Nominal voltage +24V, no-load voltage max. 36V 4) Nominal voltage +5V, 25 ma (can be switched to 2V, 25 ma after opening the cover) *) Front view of the socket (component side) and/or rear view of the plug (soldering side)

7 7 EFKA DA82GA336 (PL) BI3c ATTENTION! When connecting the outputs, ensure that a total power of 96VA constant load will not be exceeded! DB3 - Speed limitation 3 RPM ML/FSPL2 - Motor running/2nd thread tension release NHT - Needle up/down (selectable using parameter 98) FF - Flip-flop POS2 - Position 2 FSPL - Thread tension release STK - Switch stitch length FSPR - Thread tension reduction VR - Backtacking HP - High lift limitation VRU - Backtack suppression / recall IMPULSE - Speedometer impulses (52/rotation) WALZ - Roller feed LSP - Machine run blockage ZVR - Intermediate backtack ML - Motor running ) Nominal voltage 24V, no-load voltage max. 36V 2) V connection of the load circuit *) Front view of the socket (component side) and/or rear view of the plug (soldering side)

8 EFKA DA82GA336 (PL) 8 LSHQ Light barrier command (identified when switched to V) LSM or LSMA Light barrier module EB.. Actuator Pedal step # -2 - ½ Input A L L H H H L L H H L L H H L L H Input B L H H L L L H H H H L L L L H H Input C H H H H L L L L L L L L H H H H Input D H H H H H H H H L L L L L L L L Switching supply voltage 5V or 2V There is a supply voltage of +5V for external devices on the A/2 socket. After opening the cover, this voltage can be changed to +2V by replugging a multipole connector J on the printed circuit board.! Open cover! +5V = Connect left-hand pins and 2 with jumper (factory setting)! +2V = Connect right-hand pins 3 and 4 with jumper! Close cover J 2 J +5V J V KL233 ATTENTION! Before opening the control box, turn power off!

9 9 EFKA DA82GA336 (PL) 3 Timing Diagrams Trimming from full machine run - / n n3 n2 n4 n7 n7 POS tfa POS.2 FL A/35 t3 Arv Arr t Err Erv t7 t4 t5 VR A/34 STK A/3 FA A/37 FSPL A/36 FW A/27 NK A/28 ifa FSE FSA t6 24/ FALAUF Mark Function Parameter V8 V82 Double start backtack On Key Key Double end backtack On Key 2 Key 4 Slu Long stitches during backtack On 37 = ON n2 Maximum speed n3 Start backtack speed 2 n4 End backtack speed 3 n7 Trimming speed 6 Arv Start backtack stitches forward /5 Arr Start backtack stitches backward /5 Err End backtack stitches backward 2/52 Erv End backtack stitches forward 3/53 ifa Thread trimmer activation angle 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 92 tfa Stop time for thread trimmer in position 93 t Delay until speed release after start backtack 2 t3 Start delay from lifted sewing foot 22 t4 Full power of sewing foot lifting 23 t5 Holding power of sewing foot lifting 24 t6 Thread wiper ON period 25 t7 Sewing foot lifting delay time after thread wiping 26

10 EFKA DA82GA336 (PL) Backtacking with switch-on and switch off delay - / n n3 n2 n4 n7 n7 POS tfa POS.2 FL A/35 t3 Arv Arr t Err Erv t7 VR A/34 t5 t6 t7 t8 STK A/3 FA A/37 FSPL A/36 FW A/27 NK A/28 ifa FSE FSA t6 24/ RIEGEL Mark Function Parameter V8 V82 Double start backtack On Key Key Double end backtack On Key 2 Key 4 n2 Maximum speed n3 Start backtack speed 2 n4 End backtack speed 3 n7 Trimming speed 6 Arv Start backtack stitches forward /5 Arr Start backtack stitches backward /5 Err End backtack stitches backward 2/52 Erv End backtack stitches forward 3/53 t5 Switch-on delay for start backtack t6 Switch-off delay for start backtack 2 t7 Switch-on delay for end backtack 3 t8 Switch-off delay for end backtack 4 ifa Thread trimmer activation angle 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 92 tfa Stop time for thread trimmer in position 93 t Delay until speed release after start backtack 2 t3 Start delay from lifted sewing foot 22 t4 Full power of sewing foot lifting 23 t5 Holding power of sewing foot lifting 24 t6 Thread wiper ON period 25 t7 Sewing foot lifting delay time after thread wiping 26

11 EFKA DA82GA336 (PL) Machine run with intermediate stop - + / n POS. 2 3 n3 n2 n n2 n4 n7 2 POS.2 FL A/35 t3 Arr t Err t7 t4 t5 VR A/34 STK A/3 FA A/37 FSPL A/36 ifa FAE FSE FSA FW A/27 NK A/28 dnk t6 dnk 24/ LAUFZW Mark Function Parameter V8 V82 Single start backtack On Key Key Single end backtack On Key 2 Key 4 n Positioning speed n2 Maximum speed n3 Start backtack speed 2 n4 End backtack speed 3 n7 Trimming speed 6 Arr Start backtack stitches backward /5 Err End backtack stitches backward 2/52 dnk Needle cooling switch-off delay after the stop 83 ifa Thread trimmer activation angle 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 92 FAE Thread trimmer switch-on delay 94 t Delay until speed release after start backtack 2 t3 Start delay from lifted sewing foot 22 t4 Full power of sewing foot lifting 23 t5 Holding power of sewing foot lifting 24 t6 Thread wiper ON period 25 t7 Sewing foot lifting delay time after thread wiping 26

12 EFKA DA82GA336 (PL) 2 Machine run with intermediate stop and short trimmer - / n n6 n3 n2 n n2 n4 nrs n7 POS POS.2 SSc FL A/35 t3 Arr t Err t7 t4 t5 VR A/34 STK A/3 FA A/37 FSPL A/36 ifa FSE FSA K-FA A/27 (FW) NK A/28 24/ FAKURZ Mark Function Parameter V8 V82 Single start backtack On Key Key Single end backtack On Key 2 Key 4 Far Trimming stitch forward with signal output during softstart 36 = 3 and stitch before thread trimming until standstill (short trimmer) n Positioning speed n2 Maximum speed n3 Start backtack speed 2 n4 End backtack speed 3 n6 Softstart speed 5 n7 Trimming speed 6 nrs Backtack synchronization speed 24 Arr Start backtack stitches backward /5 Err End backtack stitches backward 2/52 SSc Softstart stitches ifa Thread trimmer activation angle 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 92 t Delay until speed release after start backtack 2 t3 Start delay from lifted sewing foot 22 t4 Full power of sewing foot lifting 23 t5 Holding power of sewing foot lifting 24 t6 Thread wiper ON period 25 t7 Sewing foot lifting delay time after thread wiping 26

13 3 EFKA DA82GA336 (PL) Machine run with intermediate stop and thread clamp On - + / n nfe n3 n2 n n2 n4 n7 POS POS.2 FL A/35 t3 Arr t Err t7 t4 t5 VR A/34 STK A/3 FA A/37 ifa FSPL A/36 FSE FSA FW A/27 FK A/28 K2 K K2 K t6 24/ LAUF- FK Mark Function Parameter V8 V82 Single start backtack On Key Key Single end backtack On Key 2 Key 4 FkL Thread clamp 54 = n Positioning speed n2 Maximum speed n3 Start backtack speed 2 n4 End backtack speed 3 n7 Trimming speed 6 nfe Thread pull-in speed fixed Arr Start backtack stitches backward /5 Err End backtack stitches backward 2/5 k Increments up to thread clamp enable (signal ) 55 k- Increments up to thread clamp disable (signal ) 56 k2 Increments up to thread clamp enable (signal 2) 57 k2- Increments up to thread clamp disable (signal 2) 58 ifa Thread trimmer activation angle 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 92 t Delay until speed release after start backtack 2 t3 Start delay from lifted sewing foot 22 t4 Full power of sewing foot lifting 23 t5 Holding power of sewing foot lifting 24 t6 Thread wiper ON period 25 t7 Sewing foot lifting delay time after thread wiping 26

14 EFKA DA82GA336 (PL) 4 Trimming from intermediate stop - / n n6 n3 n2 n n4 n7 POS POS.2 SSc FL A/35 t3 Arr t t3 Err t7 t4 t5 VR A/34 STK A/3 FA A/37 FSPL A/36 FW A/27 NK A/28 ifa FSE FSA t6 24/ FAZW Mark Function Parameter V8 V82 Basic position 2 On Key 4 Key 7 Single start backtack On Key Key Single end backtack On Key 2 Key 4 SSt Softstart 34 = ON n Positioning speed n2 Maximum speed n3 Start backtack speed 2 n4 End backtack speed 3 n6 Softstart speed 5 n7 Trimming speed 6 Arr Start backtack stitches backward /5 Err End backtack stitches backward 2/52 SSc Softstart stitches ifa Thread trimmer activation angle 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 92 t Delay until speed release after start backtack 2 t3 Start delay from lifted sewing foot 22 t4 Full power of sewing foot lifting 23 t5 Holding power of sewing foot lifting 24 t6 Thread wiper ON period 25 t7 Sewing foot lifting delay time after thread wiping 26 tsr Stop time for ornamental backtack 2

15 5 EFKA DA82GA336 (PL) Seam end by stitch counting - + / n n2 n4 n7 POS POS.2 FL A/35 t3 Stc Err Erv t7 t4 t5 VR A/34 STK A/3 FA A/37 FSPL A/36 FW A/27 NK A/28 ifa FSE FSA t6 24/ ENDEZAE Mark Function Parameter V8 V82 Stitch counting On --- Key 2 Double end backtack On Key 2 Key 4 n4 End backtack speed 3 n7 Trimming speed 6 n2 Stitch counting speed 8 Err End backtack stitches backward 2/52 Erv End backtack stitches forward 3/53 Stc Stitches of the seam with stitch counting 7 ifa Thread trimmer activation angle 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 92 t3 Start delay from lifted sewing foot 22 t4 Full power of sewing foot lifting 23 t5 Holding power of sewing foot lifting 24 t6 Thread wiper ON period 25 t7 Sewing foot lifting delay time after thread wiping 26

16 EFKA DA82GA336 (PL) 6 End sensing by light barrier - + / n n2 n5 n4 n7 POS POS.2 drd ird FL A/35 t3 LS Err t4 t5 VR A/34 STK A/3 FA A/37 ifa FSPL A/36 FSE FSA FW A/27 t6 t7 NK A/28 LS 24/ ENDELS Mark Function Parameter V8 V82 Single end backtack On Key 2 Key 4 LS Light barrier On 9 = ON LSd Light barrier covered/uncovered 3 = ON Frd Reversion 82 = ON n2 Maximum speed n3 Start backtack speed 2 n5 Speed after light barrier sensing 4 n7 Trimming speed 6 Err End backtack stitches backward 2/52 LS Light barrier compensating stitches 4 ird Number of reversion increments 8 drd Reversion switch-on delay 8 ifa Thread trimmer activation angle 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 92 t3 Start delay from lifted sewing foot 22 t4 Full power of sewing foot lifting 23 t5 Holding power of sewing foot lifting 24 t6 Thread wiper ON period 25 t7 Sewing foot lifting delay time after thread wiping 26

17 7 EFKA DA82GA336 (PL) Machine run with ornamental backtack (parameter 27 = OFF) - + / n n3 n n3 n n3 n2 n n4 n n4 n7 POS POS.2 FL A/35 t3 SAv tsr SAr tsr SAr tsr SEr tsr SEv VR A/34 STK A/3 FA A/37 FSPL A/36 FW A/27 NK A/28 ifa FSE FSA t6 24/ LAUFZVR Mark Function Parameter V8 V82 SrS Ornamental backtack On 35 = ON SLU Normal stitch length On 37 = ON Zrv Last counted forward section during ornamental backtack at the start 25 = ON of the seam On SSL Stop time after the ornamental backtack at the start of the seam Off 27 = OFF n Positioning speed n2 Maximum speed n3 Start backtack speed 2 n4 End backtack speed 3 n7 Trimming speed 6 SAv Number of stitches for start ornamental backtack forward 8/55 SAr Number of stitches for start ornamental backtack backward 8/56 SEr Number of stitches for end ornamental backtack backward 82/57 SEv Number of stitches for end ornamental backtack forward 83/58 ifa Thread trimmer activation angle 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 92 t3 Start delay from lifted sewing foot 22 t6 Thread wiper ON period 25 tsr Stop time for ornamental backtack 2

18 EFKA DA82GA336 (PL) 8 Machine run with ornamental backtack (parameter 27 = ON) - / n n3 n n3 n n3 n n2 n n4 n n4 n7 POS POS.2 FL A/35 t3 SAv tsr SAr tsr SAr tsr tsr SEr tsr SEv VR A/34 STK A/3 FA A/37 FSPL A/36 FW A/27 NK A/28 ifa FSE FSA t6 24/ LAUFZVR2 Mark Function Parameter V8 V82 SrS Ornamental backtack On 35 = ON SLU Normal stitch length On 37 = ON Zrv Last counted forward section during ornamental backtack at the start 25 = ON of the seam On SSL Stop time after the ornamental backtack at the start of the seam On 27 = ON n Positioning speed n2 Maximum speed n3 Start backtack speed 2 n4 End backtack speed 3 n7 Trimming speed 6 SAv Number of stitches for start ornamental backtack forward 8/55 SAr Number of stitches for start ornamental backtack backward 8/56 SEr Number of stitches for end ornamental backtack backward 82/57 SEv Number of stitches for end ornamental backtack forward 83/58 ifa Thread trimmer activation angle 9 FSA Thread tension release switch-off delay 9 FSE Thread tension release activation angle 92 t3 Start delay from lifted sewing foot 22 t6 Thread wiper ON period 25 tsr Stop time for ornamental backtack 2

19 9 EFKA DA82GA336 (PL) Machine run with high lift for walking foot - + / n n2 n n2 n POS POS.2 FL A/35 t3 hpv chp thp t2 t4 t5 NK A/34 HP A/32 HP 24/LAUFHUB Mark Function Parameter V8 V82 hpr High lift for walking foot operational mode not stored 38 = OFF Fc6 Key on socket D/6 function: high lift for walking foot 49 = n Positioning speed n2 Maximum speed n High lift walking speed 7 thp High lift walking speed run-out time 52 chp Minimum high lift walking speed 84 hpv High lift for walking foot switch-on delay 89 t2 Delay of sewing foot lifting with pedal in pos. - 2 t3 Start delay from lifted sewing foot 22 t4 Full power of sewing foot lifting 23 t5 Holding power of sewing foot lifting 24

20 EFKA DA82GA336 (PL) 2 4 List of Parameters 4. Operator Level Parameter Designation Unit Limits Preset for Ind. max min Ω 22Ω 68Ω Ω Arv st number of stitches of start backtack stitches A forward Arr st number of stitches of start backtack stitches A backward 2 Err st number of stitches of end backtack stitches A backward 3 Erv st number of stitches of end backtack stitches A forward 4 LS Light barrier compensating stitches stitches A (for long stitches) 5 LSF Number of stitches of the light barrier filter stitches 254 A for knitted fabrics 6 LSn Number of light barrier seams 5 A 7 Stc Number of stitches for the seam with stitch stitches 254 A counting 8 -F- A parameter from the technician level is assigned to A key 9 on the V82 control panel = Softstart On/Off 2 = Ornamental backtack On/Off 3 = High lift for walking foot operational mode stored = On / operational mode not stored = Off 4 = Needle cooling On/Off (only if parameter 85 = ) 5 = Reversion On/Off 6 = Switch number of stitches / 2 for start and end backtacking Number of stitches = Off, 2 = On 9 LS Light barrier On/Off ON/OFF OFF OFF OFF OFF A cls Light barrier compensating stitches stitches A (for normal stitch length) 3 FA Thread trimmer On/Off ON/OFF ON ON ON ON A 4 FW Thread wiper On/Off ON/OFF ON OFF OFF OFF A 5 StS Stitch counting On/Off ON/OFF OFF OFF OFF OFF A 5 Arv 2 nd number of stitches of start backtack stitches A forward 5 Arr 2 nd number of stitches of start backtack stitches A backward 52 Err 2 nd number of stitches of end backtack stitches A backward 53 Erv 2 nd number of stitches of end backtack stitches A forward 54 vr2 Switching st/2nd number of stitches in ON/OFF OFF OFF OFF OFF A standard backtack OFF = st number of stitches (param. -3) ON = 2 nd number of stitches (param. 5-53) 55 SAv 2 nd number of stitches of start ornamental stitches A backtack forward 56 SAr 2 nd number of stitches of start backtack stitches A backtack backward 57 SEr 2 nd number of stitches of end backtack stitches A backtack backward 58 SEv 2 nd number of stitches of end backtack stitches A backtack forward 59 Zr2 Switching st/2nd number of stitches in ON/OFF OFF OFF OFF OFF A ornamental backtack OFF = st number of stitches (param. 8-83) ON = 2 nd number of stitches (param ) Note: At the operator level, the parameter number (F-xxx) is not shown on the display, but the abbreviation (e. g. Arv) and the actual value (e. g. 2 for 2 stitches).

21 2 EFKA DA82GA336 (PL) Parameter Designation Unit Limits Preset for Ind. max min Ω 22Ω 68Ω Ω 8 SAv st number of start ornamental backtack stitches A stitches forward 8 SAr st number of start ornamental backtack stitches A stitches backward 82 SEr st number of end ornamental backtack stitches A stitches backward 83 SEv st number of end ornamental backtack stitches A stitches forward 85 ca Number of stitches A for thread monitor 999 A Parameter 95 = 4 If parameter 95 = 4, the following functions will be activated upon pressing the appropriate key: > sec. = Thread monitor function is deactivated. < sec. = Counter is set to preset value. 86 cb Number of stitches B for thread monitor A Parameter 95 = 4 87 cc Number of stitches C for thread monitor A Parameter 95 = 4 9 war Repetitions of double start backtacking 254 A 9 wer Repetitions of double end bakctacking 254 A 92 cb Number of catch backtacking stitches stitches 254 A forward 93 cb2 Number of catch backtacking stitches stitches 254 A backward Note: At the operator level, the parameter number (F-xxx) is not shown on the display, but the abbreviation (e. g. Arv) and the actual value (e. g. 2 for 2 stitches).

22 EFKA DA82GA336 (PL) Technician Level Code no. 97 with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω 22Ω 68Ω Ω SSc Number of softstart stitches stitches 254 A t5 Switch-on delay for the stitch regulator ms 255 A during start backtack 2 t6 Switch-off delay for the stitch regulator ms 255 A during start backtack 3 t7 Switch-on delay for the stitch regulator ms 255 A during end backtack 4 t8 Switch-off delay for the stitch regulator ms 255 A during end backtack n Positioning speed RPM A n2- Upper limit setting range of the maximum RPM 5 n2_ A speed 2 n3 Start backtacking speed RPM A 3 n4 End backtacking speed RPM A 4 n5 Speed after light barrier sensing RPM A 5 n6 Softstart speed RPM A 6 n7 Trimming speed RPM A 7 n High lift walking speed RPM A = speed limitation (DB2) 8 n2 Automatic speed for stitch counting RPM A according to setting of parameter 4 9 nst Speed stage graduation 3 A = linear 2 = slightly progressive 3 = highly progressive 2 nnk Whenever this speed is exceeded, RPM A needle cooling is activated, if parameter 85 is set to 3 2 n2_ Lower limit setting range of the maximum RPM n A speed 23 tns End backtack synchronization time ms A 24 nrs End backtack synchronization speed RPM A 27 AkS Acoustic signal during machine run blockage or 3 A thread monitor (pa. 95 = 4 and according to the setting of the number of stitches by means of parameter 85) = Acoustic signal Off = Acoustic signal from stop after execution of stitches to pressing key 8. 2 = Drive stops after execution of stitches. Sewing is possible up to the seam end. After that the acoustic signal is issued until key 8 is pressed. 3 = Drive stops after execution of stitches, and the acoustic signal is issued 5 times. Sewing is possible up to the seam end. After that the acoustic signal is issued until key 8 is pressed. 28 Asd Start delay, when command start is ms 2 A given by covering the light barrier (only if parameter 29 = ON)

23 23 EFKA DA82GA336 (PL) Technician Level Code no. 97 with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω 22Ω 68Ω Ω 29 ALS Automatic start by light barrier On/Off: ON/OFF OFF OFF OFF OFF A machine start by covering the light barrier, without having heeled the pedal back to the basic position. Additional prerequisites: - Parameter 32 = ON - Function light barrier sensing enabled on the control panel - Initiation of the first normal seam section (pedal in the basic position) - Cover light barrier - Press pedal forward - Keep pedal pressed forward Deactivate this function by heeling the pedal back to the basic position. 3 LSF Light barrier filter for knitted fabrics On/Off ON/OFF OFF OFF OFF OFF A 3 LSd OFF = Light barrier sensing covered ON/OFF ON ON ON ON A ON = Light barrier sensing uncovered 32 LSS OFF = Machine start possible with light ON/OFF ON ON ON ON A barrier uncovered or covered. ON = Machine start blocked with light barrier uncovered if pa. 3 = ON. Machine start blocked with light barrier covered if pa. 3 = OFF. 33 LSE Thread trimming operation, when ON/OFF ON ON ON ON A completing the seam after light barrier sensing On/Off 34 SSt Softstart On/Off ON/OFF ON ON ON ON A 35 SrS Ornamental backtack On/Off ON/OFF OFF OFF OFF OFF A 36 FAr Power transistor function on A/27 (functions: 4 A thread trimmer, thread wiper and short trimmer) = Trimming stitch forward and thread wiper function On = Trimming stitch backward and thread wiper function On 2 = Trimming stitch forward with short trimmer signal On. Thread wiper function Off. 3 = Trimming stitch forward with signal for stitch length reduction during softstart and signal for short trimmer On. Thread wiper function Off. 4 = Trimming stitch forward with signal for stitch length reduction during softstart. Thread wiper function Off. 37 SLU Stitch length during backtack ON/OFF ON OFF OFF OFF A OFF= long stitches ON = normal stitches 38 hpr OFF = High lift for walking foot ON/OFF OFF OFF OFF OFF A operational mode not stored ON = High lift for walking foot operational mode stored 39 nis Display of machine speed On/Off ON/OFF OFF OFF OFF OFF A 4 nh Mode key needle up/down on socket A/ A = Needle up 2 = Needle up/down 3 = Single stitch 4 = Single stitch with stitch length switching 5 = Needle up if outside position 2 6 = Machine stop in position 2 and sewing foot up. Machine run blockage symbol flashing on V82 and stop on V8, respectively. After power Off/On the drive is ready again.

24 EFKA DA82GA336 (PL) 24 Technician Level Code no. 97 with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω 22Ω 68Ω Ω 4 SGn Speed status for the seam with stitch counting 3 A = Speed controllable by the pedal up to the set maximum speed (parameter ) = Fixed speed (parameter 8) without influence by the pedal (machine stop by pressing the pedal to the basic position) 2 = Limited speed controllable by the pedal up to the set limit (parameter 8) 3 = At fixed speed (parameter 8) can be interrupted by full heelback 42 SFn Speed status for the free seam and for the seam 3 A with light barrier = Speed controllable by the pedal up to the set maximum speed (parameter ) = Fixed speed (parameter 8) without influence by the pedal (machine stop by pressing the pedal to the basic position) 2 = Limited speed controllable by the pedal up to the set limit (parameter 8) 3 = At fixed speed (parameter 8) can be interrupted by full heelback (only in conjunction with light barrier On, otherwise like setting ) 44 nh2 Mode key needle up/down on socket D/ 6 A = Needle up 2 = Needle up/down 3 = Single stitch 4 = Single stitch with stitch length switching 5 = Needle up if outside position 2 6 = Machine stop in position 2 and sewing foot up. Machine run blockage symbol flashing on V82 and stop on V8, respectively. After power Off/On the drive is ready again. 45 StL Normal/long stitches with/without speed limitation. 3 A Key on socket D/2. = Normal/long stitches without speed limitation 2 = Normal/long stitches without speed limitation (DB2) 3 = Normal/long stitches without speed limitation (DB3) 47 Fc3 Function of the key on socket D/3 3 A = Thread tension reduction 2 = Backtack suppresion/recall 3 = Roller 4 = High lift for walking foot 48 Fc5 Function of the key on socket D/ A = Speed limitation (DB3) 2 = Intermediate backtack 49 Fc6 Function of the key on socket D/6 3 A = High lift for walking foot 2 = Thread tension reduction 3 = Roller

25 25 EFKA DA82GA336 (PL) Technician Level Code no. 97 with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω 22Ω 68Ω Ω 52 thp Run-out time of the high lift walking speed ms 5 8 A after disabling the high lift for walking foot 53 brt Braking power at machine standstill A 54 FkL Thread clamp function 7 A = Thread clamp Off = Thread clamp function when using the values of parameters = Preset values (see table in the instruction manual) The thread clamp functions are performed at a fixed speed of 25 RPM! 55 k Increments up to enabling of the thread incr. 5 A clamp (signal ) 56 k- Increments up to disabling of the thread incr A clamp (signal ). This parameter setting value must not be lower than that of parameter k2 Increments up to enabling of the thread incr. 5 A clamp (signal 2) 58 k2- Increments up to disabling of the thread incr. 5 A clamp (signal 2). This parameter setting value must not be lower than that of parameter dre Direction of motor rotation A = Clockwise rotation = Counterclockwise rotation 7 Sr Setting the reference position: ****) A - Press the E key. - Press the >> key. - Position = Needle point at the height of the needle plate, from downward movement of the - needle in the direction of rotation of the motor - shaft. 7 Sr2 Setting the needle positions: ****) Press key E. Press key >>. = Position (leading edge) A Press key E. 2 = Position 2 (leading edge) A Press key E. A = Position (trailing edge) A Press key E. 3 = Position 3 no function 5 A Press key E. 3A = Position 3 no function 5 A (for changing the values turn handwheel or press key +/-) Press key P twice. Settings are completed! 72 Sr3 Display on the V8 control panel: Pos. to A (left-hand arrow above key 4 On) Pos. 2 to 2A (right-hand arrow above key 4 On) Function active only after sewing has been started once! 72 Sr3 Display on the V82 control panel: Pos. to A (left-hand arrow above key 7 On) Pos. 2 to 2A (right-hand arrow above key 7 On) Function active only after sewing has been started once! ****) For more detailed instructions see instruction manual!

26 EFKA DA82GA336 (PL) 26 Technician Level Code no. 97 with control panel operation Parameter Designation Unit Limits Preset for Ind. 73 Sr4 Checking of the signal outputs and inputs using the V8/V82 control panels - Select the desired output using the +/- key - Activate the selected output using the >> key = Backtacking on socket A/34 2 = Sewing foot lift on socket A/35 3 = Thread trimmer on socket A/37 4 = Thread wiper on socket A/27 5 = Stitch length switching on socket A/3 6 = Thread tension release on sockets A/36, B/5, C/5 7 = Thread tension reduction on socket A/2 8 = Needle cooling on socket A/28 9 = Motor running on sockets A/26, B/6 = High lift for walking foot on socket A/32 = No assignment on socket A/22 2 = LED for needle up/down on socket D/9 3 = LED for long stitch on socket D/ 4 = Thread clamp on socket A/8 5 = LED for high lift for walking foot on socket A/3 6 = LED for right-hand thread monitor on socket A/25 7 = LED for sewing foot pressure reduction on socket D/2 8 = LED for thread tension reduction/backtack suppression/recall on socket D/ 9 = Sewing foot pressure reduction on socket A/2 2 = LED for left-hand thread monitor on socket A/23 2 = Flip-flop on socket C/6 22 = LED for high lift limitation/thread tension reduction on socket D/4 23 = LED for backtack suppression/recall on socket A/24 24 = LED for speed limitation 3 / intermediate backtack on socket D/3 (effective only in conjunction with the key on socket D/5) 25 = LED for long stitch on socket A/29 26 = No assignment on socket A/7 27 = No assignment on socket A/6 28 = Roller feed on socket A/5 max min Ω 22Ω 68Ω Ω OFF/ON = By actuating the switches connected to the control, the function of these switches is checked and ON/OFF is displayed on the V8/V82 control panels 79 Sr5 V82 control panel display: Control program number with index and identification number. V8 control panel display: Upon pressing the << key, data will be displayed in succession. 8 ird Number of reversing increments incr A 8 drd Switch-on delay of reverse motor rotation ms 99 A 82 Frd Reverse motor rotation On/Off ON/OFF OFF OFF OFF OFF A 83 dnk Switch-off delay of needle cooling after ms A stop or falling below the switch speed (parameter 2) 84 chp Minimum number of stitches for high lift stitches A for walking foot 85 Fnk Function of the output needle cooling 3 A = Needle cooling 2 = Reserved for option 3 = Needle cooling depending on speed (the switch speed can be set using pa. 2)

27 27 EFKA DA82GA336 (PL) Technician Level Code no. 97 with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω 22Ω 68Ω Ω 86 ctw Stitches until roller lowering stitches A 87 Stn Stitch length in the next seam (after the thread 3 A trimming operation) = The selected stitch length remains On. 2 = Switch to long stitches after thread trimming. 3 = Switch to normal stitches after thread trimming. 88 hp Minimum speed level for high lift for walking foot 2 A Maximum speed level for high lift for walking foot 2 A Assignment of maximum speed (parameter ) and minimum speed (parameter 7 = high lift walking speed) to the 2 speedomat levels. Display example: = Display of the level up to which the maximum speed is effective. 9 = Display of the level up to which the minimum speed is effective. = Display of the level set on the speedomat (potentiometer). 274 = Corresponding speed See instruction manual on how to change the setting! 89 hpn ON - High lift for walking foot with speed ON/OFF ON ON ON ON A limitation (parameter 7) OFF - High lift for walking foot with a 5 ms speed limitation (parameter 7) 9 ifa Activation angle of the thread trimmer incr A ( increment corresponds to.7 ) Set to 8 with series N29 and 8967! 9 FSA Thread tension release switch-off delay ms A 92 FSE Angle of thread tension release switch on incr A delay (i increment corresponds to.7 ) 93 tfa Thread trimmer stop time ms 5 3 A 94 FAE Angle of thread timmer switch-on delay incr. 45 A 95 rfw Thread monitor mode 4 A = No thread monitor function. = Model 27 or short seams. Without stop, sewing foot down after thread trimming. 2 = Model 767/N29. With stop, sewing foot up after thread trimming. 3 = Model 767/N29. With stop, sewing foot down after thread trimming. 4 = With thread monitor stitch counting (max. 999 stitches) Number of stitches according to setting of parameter 85, 86, kfn = Thread tension release and thread tension 3 A reduction Off during sewing foot lifting. = Thread tension release and thread tension reduction On during sewing foot lifting in the seam. 2 = Thread tension release and thread tension reduction On during sewing foot lifting after thread trimming. 3 = Thread tension release and thread tension reduction On during sewing foot lifting in the seam and after thread trimming. If parameter 47 = (key on socket D/3) or parameter 49 = 2 (key on socket D/6), thread tension reduction can be enabled at any time. The operational mode of the keys is stored.

28 EFKA DA82GA336 (PL) 28 Technician Level Code no. 97 with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω 22Ω 68Ω Ω 97 kfh = Coupling thread tension reduction with high 3 A lift for walking foot and speedomat Off. = Thread tension reduction is disabled and high lift for walking foot enabled using the key on socket A/7. The speedomat has no effect. 2 = When reaching the high lift walking speed by adjusting the speedomat, thread tension reduction is disabled. The key on socket A/7 has no effect. 3 = When reaching the high lift walking speed by adjusting the speedomat, thread tension reduction is disabled. The key on socket A/7 works as with setting. If parameter 47 = (key on socket D/3) or parameter 49 = 2 (key on socket D/6), thread tension reduction can be enabled at any time. The operational mode of the keys is stored. 98 mml = Motor running (output B5/6) A 2 = 2nd thread tension release n > Param. 2, FSPL2 = On n < Param. 2, FSPL2 = Off 3 = 2nd thread tension release n < Param. 2, FSPL2 = On n > Param. 2, FSPL2 = Off

29 29 EFKA DA82GA336 (PL) 4.3 Supplier Level Code no. 36 with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω 22Ω 68Ω Ω 2 t Delay until speed release after start ms A backtack 2 t2 Sewing foot lift switch-on delay with half ms A heelback 22 t3 Start delay after disabling the sewing foot ms A lift signal 23 t4 Time of full power of sewing foot lifting ms A 24 t5 Holding power for sewing foot lifting A Stages,...7 Stage # % high holding power Stage # 2.5% low holding power Stage 7 # 87.5% 25 t6 Thread wiper time ms 5 A 26 t7 Delay from end of thread wiper until ms A sewing foot lifting On 27 br Braking effect when modifying the preset value 4 stages Preset value if parameter 225 = A Preset value if parameter 225 = A Preset value if parameter 225 = A Preset value if parameter 225 = A 28 br2 Braking effect when modifying the preset value 5 stages Preset value if parameter 225 = A Preset value if parameter 225 = A Preset value if parameter 225 = A Preset value if parameter 225 = A 2 tsr Stop time for switching the stitch regulator ms C in the ornamental backtack 22 t Time of full power of backtacking ms A 23 t Holding power for backtacking A Stages,...7 Stage # % high holding power Stage # 2.5% low holding power Stage 7 # 87.5% 25 Zrv OFF = Last counted forward section in ON/OFF ON ON ON ON A the start backtack OFF ON = Last counted forward section in the start backtack ON 26 FLS OFF = Fast disabling of sewing foot lift ON/OFF ON ON ON ON A Off ON = Fast disabling of sewing foot lift On 27 SSL OFF = Stop time after the ornamental ON/OFF OFF OFF OFF OFF A backtack at the start of the seam Off ON =,Stop time after the ornamental backtack at the start of the seam On, if parameter 35 / 37 = ON 22 ALF Accelerating power of the drive Preset value if parameter 225 = A Preset value if parameter 225 = A Preset value if parameter 225 = A Preset value if parameter 225 = A 225 reg = Normal machines A = Medium-duty machines 2 = Heavy-duty machines 3 = Machine models 48 and 428 The preset values of parameters 27, 28 and 22 change depending on the setting of parameter 225. See respective parameters.

30 EFKA DA82GA336 (PL) 3 Supplier Level Code no. 36 with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω 22Ω 68Ω Ω 23 Sn Execution of the st stitch after power On ON/OFF OFF OFF OFF OFF A at positioning speed. 26 PLc Time interval which can be varied by ON/OFF OFF OFF OFF OFF A means of the number of stitches performed after sewing foot lowering until roller lowering in the seam On/Off (setting by means of parameter 86). OFF = Time interval which can be varied by the number of stitches performed Off ON = Time interval which can be varied by the number of stitches performed On 26 FLk = Lift roller 3 A = Lift roller with sewing foot lift or backtack 2 = Lift roller with sewing foot lift 3 = Lift roller with backtack 262 hpt = Roller remains lowered when enabling A high lift for walking foot. = Roller is lifted when enabling high lift for walking foot. 275 Std Seam suppression when stitches have been set A 276 dkn = Correction seam Off 2 A = Correction seam On 2 = Interruption of seam or pattern by thread trimming 277 nfs Select: Switch from one seam or pattern to the A next = Switch from one seam to the next = Switch from one pattern to the next 28 SEL Display of the select resistor values (socket A/-4) A for the following machine series: Ω = 27 N29, 8967 (set parameter 9 to 8) 22Ω = 24, 25, 22, 266, Ω = 69, 267, 268, 269, 48, 428 Ω = 38, 382, 467, 767, Pd New sewing start after machine run ON/OFF ON ON ON ON A blockage ON = Immediate start OFF = Only with pedal in position (neutral) 282 LoS Functioning of the switch for machine run blockage A = Make contact (N.O.) = Break contact (N.C.) 283 LSP Function machine run blockage 2 A = Function Off = Blockage, without positioning 2 = Blockage 2, with positioning 287 dba Speed limitation (n) DB3 for manual A backtack = Speed limitation Off = Speed limitation On 288 n9 Speed limitation (n9) for manual RPM A ornamental backtack 289 n Speed limitation (n) DB3 for RPM A manual backtack

31 3 EFKA DA82GA336 (PL) Supplier Level Code no. 36 with control panel operation Parameter Designation Unit Limits Preset for Ind. max min Ω 22Ω 68Ω Ω 29 8 Selection of the slide-in strip number for control A panel V8 (illustration of slide-in strips see chapter Slide-in Strips Control Panel V8 ). Function of key 4 on the control panel: Strip -9 Basic position or 2 Strip Thread trimmer/thread wiper On/Off 293 tf Selection of the input function using key (A) A F on the V8 control panel = No function = Needle up 2 = Needle up/down 3 = Single stitch (basting stitch) 4 = Single stitch with stitch length switching 5 = Needle up if outside position 2 6 = Switch stitch length 7 = Thread tension 8 = Sewing foot pressure 9 = Roller = Speed limitation DB3 = No function 2 = No function 3 = High lift for walking foot operational mode stored/not stored according to setting of parameter 38 4 = No function 5 = No function 6 = Intermediate backtack 7 = Backtack suppression / recall 8 = Coupling the sewing foot with thread tension release (parameter 96 > ) On/Off 9 = Set thread monitor counting (parameter 95 = 4) 294 tf2 Selection of the input function using key (B) 9 A F2 on the V8/V82 control panel Functions of the key as with parameter tfl Time monitoring of sewing foot lift sec 25 A (monitoring off at )

32 EFKA DA82GA336 (PL) 32 5 Error Displays General Information On the V8 On the V82 Signification InF A InF A Pedal not in neutral position, when turning the machine on -StoP- flashing Symbol flashing Machine run blockage InF A3 InF A3 The position to which all position values refer has not been stored (reference position missing) InF A5 InF A5 Emergency run, identification of an invalid machine select Programming Functions and Values (Parameters) On the V8 On the V82 Signification Returns to the Like V8 + Wrong code number or parameter number input first digit display InF F Serious Condition On the V8 On the V82 Signification InF E InF E After power On, postion transmitter or commutation transmitter defective or connecting cables have been changed by mistake. During machine run or after a sewing operation, only position transmitter defects can be identified. InF E2 InF E2 Line voltage too low, or time between power Off and power On too short. InF E3 InF E3 Machine blocked or does not reach the desired speed. InF E4 InF E4 Control disturbed by deficient grounding or loose contact. Hardware Disturbance On the V8 On the V82 Signification InF H InF H Commutation transmitter cord or frequency converter disturbed. InF H2 InF H2 Processor disturbed

33 33 EFKA DA82GA336 (PL) 6 Slide-in Strips for the V8 Control Panel 2 F F2 F R 3 4 F F2 5 F F2 6 F F2 7 F F2 8 F F2 A B A B B C D F A,B,C,D 9 KL253

34 EFKA DA82GA336 (PL) 34 For your notes:

35 35 EFKA DA82GA336 (PL) For your notes:

36 FRANKL & KIRCHNER GMBH & CO KG SCHEFFELSTRASSE SCHWETZINGEN GERMANY PHONE: FAX: OF AMERICA INC. 375 NORTHCREST ROAD SUITE ATLANTA GEORGIA 334 PHONE: + (77) FAX: + (77) efkaus@bellsouth.net ELECTRONIC MOTORS SINGAPORE PTE. LTD. 67, AYER RAJAH CRESCENT 5-3 SINGAPORE 3995 PHONE: FAX: efkaems@efka.net ()-2726-A (4236 EN)

CONTROL DA82GA3312 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS. with control panel V810/V820

CONTROL DA82GA3312 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS. with control panel V810/V820 CONTROL DA82GA332 with control panel V8/V82 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS No. 42276 English FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS GMBH & CO KG SINGAPORE

More information

CONTROL DA220C5300 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS.

CONTROL DA220C5300 LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS. CONTROL DAC5 I P E + - >> KL4a LIST OF PARAMETERS CONNECTION DIAGRAM TIMING DIAGRAMS No. 465 English FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS GMBH & CO KG SINGAPORE PTE. LTD. EFKA

More information

FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA SINGAPORE PTE. LTD.

FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA SINGAPORE PTE. LTD. - YA620A5080 CONTROL YA620A 5080 Operating manual With parameter list - Putting into Service - Settings - Functional Description - Connection Diagrams - Timing Diagrams No. 402454 English FRANKL & KIRCHNER

More information

FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS

FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS dc5xx CONTROL dc5 ABA5 ABA5 dc55 ABA5 ABA5 LIST OF PARAMETERS No. 8 English FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS GMBH & CO KG SINGAPORE PTE. LTD. EFKA ABA/ABA + ABA/ABA (PL) CONTENTS

More information

Part 1: Operating Instructions Cl

Part 1: Operating Instructions Cl Contents Page: Preface and General Safety Information Part 1: Operating Instructions Cl. 381-382 1. Product Description........................... 5 2. Proper Use................................. 5 3.

More information

AB286A5400 KL2341 INSTRUCTION MANUAL FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS

AB286A5400 KL2341 INSTRUCTION MANUAL FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS CONTROL AB286A5400 AB286A5400 KL2341 INSTRUCTION MANUAL No. 402280 English FRANKL & KIRCHNER EFKA OF AMERICA INC. EFKA ELECTRONIC MOTORS GMBH & CO KG SINGAPORE PTE. LTD. 3 EFKA AB286A5400 CONTENTS Page

More information

Part 1: Operating Instructions Cl. 271 to 274

Part 1: Operating Instructions Cl. 271 to 274 Contents Page: Preface and General Safety Notes Part 1: Operating Instructions Cl. 271 to 274 1. Product Description 1.1 Short Description and Proper Use..................... 5 1.2 Technical Data................................

More information

DAC basic/classic Instructions for use. Software version: B03.0 or later

DAC basic/classic Instructions for use. Software version: B03.0 or later DAC basic/classic Instructions for use Software version: B03.0 or later IMPORTANT READ CAREFULLY BEFORE USE KEEP FOR FUTURE REFERENCE All rights reserved. Property of Dürkopp Adler AG and protected by

More information

PicoDrive P45 PD2-L EcoDrive P74 ED-L

PicoDrive P45 PD2-L EcoDrive P74 ED-L Industrial PicoDrive P45 PD2-L EcoDrive P74 ED-L INSTRUCTION MANUAL This Instruction Manual is valid for drives from the following software version on: P45 PD2-L # 4_045_05 P74 ED-L # 1_074_08 296-12-19

More information

FBX-PA-2AC. Third edition : April No

FBX-PA-2AC. Third edition : April No FBX-PA-2AC Third edition : April 2006 No. 060058 INTRODUCTION Thank you very much for purchasing Kansai Special FBX series. Read and study this Instruction Manual carefully before you start any of the

More information

CONTENTS PRECAUTIONS BEFORE STARTING OPERATION PREPARATION FOR OPERATION CAUTIONS ON USE OPERATION

CONTENTS PRECAUTIONS BEFORE STARTING OPERATION PREPARATION FOR OPERATION CAUTIONS ON USE OPERATION CONTENTS PRECAUTIONS BEFORE STARTING OPERATION ------------------------------------- 1 PREPARATION FOR OPERATION 1. Adjustment of needle bar stop position ---------------------------------------------------------

More information

Part 3: Service Instructions Cl

Part 3: Service Instructions Cl Contents Page: Part 3: Service Instructions Cl. 550--. General................................................. 3. Setting the Machine Head...................................... 4. Arm Shaft Crank............................................

More information

Instruction manual. Printed: Czech Republic

Instruction manual. Printed: Czech Republic Instruction manual 525 Minerva Boskovice, a.s., Sokolská 60, CZ - 680 17 Boskovice Tel.: +420-516-453434, 453433, 494111 Fax: +420-516-452165 http://www.minerva-boskovice.com Edition : 01/2004 Printed:

More information

Instruction manual. Printed: Czech Republic

Instruction manual. Printed: Czech Republic Instruction manual 524 Minerva Boskovice, a.s., Sokolská 60, CZ - 680 17 Boskovice Tel.: +420-516-453434, 453433, 494111 Fax: +420-516-452165 http://www.minerva-boskovice.com Edition : 01/2004 Printed:

More information

USER S MANUAL. KM-2070P SERIES Electronically Controlled 1-Needle ZigZag Lock Stitch Machine Electronic Control Part

USER S MANUAL. KM-2070P SERIES Electronically Controlled 1-Needle ZigZag Lock Stitch Machine Electronic Control Part USE S MANUAL KM-2070P SEIES Electronically Controlled 1-Needle ZigZag Lock Stitch Machine Electronic Control Part Best Quality Best Price Best Service 1. Thank you for purchasing our product. Based on

More information

Spezialnähmaschine. Betriebsanleitung. Instruction manual. Manuel d'instructions

Spezialnähmaschine. Betriebsanleitung. Instruction manual. Manuel d'instructions 767 Spezialnähmaschine Betriebsanleitung Instruction manual Manuel d'instructions D GB F Postfach 17 03 51, D-33703 Bielefeld Potsdamer Straße 190, D-33719 Bielefeld Telefon +49 (0) 5 21 / 9 25-00 Telefax

More information

Direct Drive Programmable electronic pattern sewer with cylinder bed

Direct Drive Programmable electronic pattern sewer with cylinder bed Direct Drive Programmable electronic pattern sewer with cylinder bed BAS-342G 300 200mm Beautiful pattern stitching, faithful to sewing data Max. sewing speed of 2,700 rpm (with stitch length 3.5 mm) Strong

More information

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16 MZ Servomotor for butterfly valves VF, VFH delta-elektrogas.com EE157-01/16 MZ Servomotor Contents Description.... 2 Features........ 2 Functioning and application..... 3 Technical specifications......

More information

LS2-B891 LT2-B892 LS2-B891-05, LT2-B892-05

LS2-B891 LT2-B892 LS2-B891-05, LT2-B892-05 LS2-B891 LT2-B892 Single Needle Unison Feed Lock Stitcher Single Needle Unison Feed Lock Stitcher with Thread Trimmer Twin Needle Unison Feed Lock Stitcher Twin Needle Unison Feed Lock Stitcher with Thread

More information

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , , maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers 249630, 249631, 249632, 318305, 381510 September 2009 edition The DEC (Digital EC Controller) is a 1-quadrant amplifier for controlling electronically

More information

S-85SCH

S-85SCH 4411-4423-4432-4443-4452 5511-5523-5532-5554 44S-85SCH Service Manual 104 73 14-26 2014-02-24 CONTENTS 1. Names of principal parts...2 2. Removing methods of external parts 2-1 Sewing table...3 2-2 Face

More information

SERVICE MANUAL PARTS LIST MODEL: NH40

SERVICE MANUAL PARTS LIST MODEL: NH40 SERVICE MANUAL & PARTS LIST MODEL: NH40 CONTENTS What to do when... 1-3 SERVICE ACCESS Face Cover... 4 Bed Cover... 5 Free-arm Cover... 6 Front Cover... 7 Rear Cover... 8 MECHANICAL ADJUSTMENT Presser

More information

Industrial 3721/3741/3745. Documented Quality - Stitch by Stitch

Industrial 3721/3741/3745. Documented Quality - Stitch by Stitch Industrial 3721/3741/3745 Documented Quality - Stitch by Stitch Documented quality The POWERLINE 3721, 3741 and 3745 are quality assurance systems designed for use on safety relevant seams. The PFAFF docu-sewing

More information

WX8800 WX8700 LX5801 WX8842 WX MC30

WX8800 WX8700 LX5801 WX8842 WX MC30 WX8800 WX8700 LX5801 WX8842 WX8842-1 MC30 First published : August 1991 Third edition : August 2004 No. 040037 INTRODUCTION Thank you for your purchasing Kansai Special's WX Series. Read and study this

More information

Operator s Guide. Sequin Device. Version 1.3. Published by: ZSK Stickmaschinen GmbH - Dokumentation - D Krefeld-Gartenstadt

Operator s Guide. Sequin Device. Version 1.3. Published by: ZSK Stickmaschinen GmbH - Dokumentation - D Krefeld-Gartenstadt Operator s Guide Sequin Device Version 1.3 Published by: ZSK Stickmaschinen GmbH - Dokumentation - D-47800 Krefeld-Gartenstadt Magdeburger Str. 38 40 04 by ZSK, Printed in Germany Subject to change. 04

More information

41P PFAFF HOBBY SERGER

41P PFAFF HOBBY SERGER 41P PFAFF HOBBY SERGER ow po On top of it. or damage to machine. threading and sewing. PERFORMANCE CHECKLIST 12 CHANGING NEEDLE 12 CARING FOR YOUR MACHINE 12 JOIN TWO PIECES OF FABRIC 12 DECORATIVE FLATLOCK

More information

Revolutionary / 96

Revolutionary / 96 Industrial 2595/96 Revolutionary... The combination of revolutionary design and innovative engineering has led to the development of something quite special, extraordinary something, which will influence

More information

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection Quick Start Guide TECO F510 Inverter This guide is to assist you in installing and running the inverter and verify that it is functioning correctly for it s main and basic features. For detailed information

More information

Single Needle Direct Drive Lock Stitcher with Electronic Feeding System and Thread Trimmer

Single Needle Direct Drive Lock Stitcher with Electronic Feeding System and Thread Trimmer S-7300A Single Needle Direct Drive Lock Stitcher with Electronic Feeding System and Thread Trimmer The world s first lock stitch sewing machine which adopts the Electronic Feed Control directly connected

More information

M PREMIUM. Additional Instructions. Neat seam beginning (NSB)

M PREMIUM. Additional Instructions. Neat seam beginning (NSB) 867 867-M PREMIUM Additional Instructions Neat seam beginning (NSB) IMPORTANT READ CAREFULLY BEFORE USE KEEP FOR FUTURE REFERENCE All rights reserved. Property of Dürkopp Adler AG and protected by copyright.

More information

FBX1104P FBX1104 FBX1106P FBX1106

FBX1104P FBX1104 FBX1106P FBX1106 FBX1104P FBX1104 FBX1106P FBX1106 Second edition : September 2004 No. 040037 INTRODUCTION Thank you for your purchasing Kansai Special's FBX Series. Read and study this instruction manual carefully before

More information

KE-430F BE-438F. Electronic direct drive lockstitch bar tacker. Electronic direct drive lockstitch button sewer

KE-430F BE-438F. Electronic direct drive lockstitch bar tacker. Electronic direct drive lockstitch button sewer KE-F lockstitch bar tacker BE-8F lockstitch button sewer Stable thread tightening and thread trimmer when sewing from foundation to denim. High quality sewing will be realized at various materials. KE-F

More information

TIPS & TROUBLESHOOTING

TIPS & TROUBLESHOOTING Achieving good stitch quality 5450 North W Street Pensacola FL 32505 850-433-1414 www.martellinotions.com TIPS & TROUBLESHOOTING Understanding how your long arm machine makes a stitch will help you make

More information

Industrial motor controller for brushed DC motors 24 VDC

Industrial motor controller for brushed DC motors 24 VDC Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 5 A Control with the following functions: - reversal of direction of rotation - open-loop speed control (external)

More information

Tube Facing Tool.

Tube Facing Tool. www.swagelok.com Tube Facing Tool This manual contains important information for the safe and effective operation of the Swagelok TF72 series tube facing tool. Users should read and understand its contents

More information

SERVICE MANUAL AND PARTSLIST

SERVICE MANUAL AND PARTSLIST SERVICE MANUAL AND PARTSLIST Next 20 CONTENTS WHAT TO DO WHEN... 1~3 SERVICE ACCESS FACE COVER... 4 TOP COVER... 4 BASE COVER... 5 REAR COVER... 6 FRONT COVER... 7 MECHANICAL ADJUSTMENT NEEDLE THREAD TENSION...

More information

FLEXRISE2 VERSION. 2 LEG / 2 MOTOR ELECTRIC TABLE BASE (36 to 72 ) **PATENT PENDING**

FLEXRISE2 VERSION. 2 LEG / 2 MOTOR ELECTRIC TABLE BASE (36 to 72 ) **PATENT PENDING** FLEXRISE2 2 LEG / 2 MOTOR ELECTRIC TABLE BASE (36 to 72 ) VERSION A INSTRUCTION MANUAL CONTENTS: FLEX-MU-2L3S-C3672-K4# FEET-ADJ-UNV-2430# **PATENT PENDING** MAX Load 265 lbs (120 KG) Equally Divided MAX

More information

Lockstitch machine with automatic thread trimmer J-150QVP INSTRUCTION MANUAL EN IMPORTANT: Read all safety regulations carefully and understand them before using your sewing machine. Retain this instruction

More information

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors Servo Amplifier -Quadrant PWM for Brushless DC-Servomotors Series BLD 010 Operating Instructions Index Chapter 1. Description 2. Illustration 3. Specification. Dimensions. Safety notes.1 Skilled personnel.2

More information

LZ-2290A-SR / IP-100D / SC-916

LZ-2290A-SR / IP-100D / SC-916 R Computer-controlled, Direct-drive, High-speed, -needle, Lockstitch, Zigzag Stitching Machine (Quick-reverse type) LZ-90A-SR / IP-00D / SC-96 INSTRUCTION MANUAL NOTE : Read safety instructions carefully

More information

MF-7700 U10 C10 E10. Universal type (basic type) for Elastic lace attaching (with right hand fabric trimmer) for Collarette attaching

MF-7700 U10 C10 E10. Universal type (basic type) for Elastic lace attaching (with right hand fabric trimmer) for Collarette attaching U10 Universal type (basic type) C10 for Collarette attaching E10 for Elastic lace attaching (with right hand fabric trimmer) MF-7723U10B56/UT33 High-speed, Flat-bed, Top and Bottom Coverstitch Machine

More information

DPFHP451 HIGH PERFORMANCE BILEVEL STEP MOTOR / MANUAL PRESET INDEXER DRIVER PACK

DPFHP451 HIGH PERFORMANCE BILEVEL STEP MOTOR / MANUAL PRESET INDEXER DRIVER PACK DPFHP451 HIGH PERFORMANCE BILEVEL STEP MOTOR / MANUAL PRESET INDEXER DRIVER PACK Internal Index Count switches Pulse Rates up to 14,792 pulses per second CW & CCW Home, Hard, & Soft Limit Inputs Adjustable

More information

Electronic direct drive zigzag lock stitcher with thread trimmer

Electronic direct drive zigzag lock stitcher with thread trimmer DD Electronic direct drive zigzag lock stitcher Electronic direct drive zigzag lock stitcher with thread trimmer Clean Economical models with low power consumption Good response, comfortable sewing Multifunctional

More information

MF-7000 Series 2-3 Needle Cylinder Bed Coverseam Machine

MF-7000 Series 2-3 Needle Cylinder Bed Coverseam Machine R 2-3 Needle Flat Bed Coverseam Machine MF-7000 Series 2-3 Needle Cylinder Bed Coverseam Machine MFC-7000 Series ENGINEER S MANUAL 29275609 No.02 PREFACE This Engineer s Manual is written for the technical

More information

MAIN PARTS

MAIN PARTS MAIN PARTS 7 8 9 10 11 12 13 1 2 3 17 4 5 6 01 02 03 04 05 12 23 34 45 56 13 24 35 46 57 14 25 36 47 58 15 16 26 27 37 38 48 49 59 60 06 07 08 09 10 17 18 28 29 39 40 50 51 61 62 19 30 41 52 63 20 21 31

More information

Intro to the Sewing Machine

Intro to the Sewing Machine Intro to the Sewing Machine 1. Bobbin Cover Opens to allow you to put the bobbin and bobbin case in the machine. 2. Stitch Plate Where the seam allowance guidelines are found. Each line is 1/8 apart, beginning

More information

UK10 UK11. First published: June No.KX03023

UK10 UK11. First published: June No.KX03023 UK10 UK11 First published: June 2003 No.KX03023 INTRODUCTION Thank you for purchasing Kansai Special s UK series machine. Please study this instruction manual carefully before operating the machine. 1.

More information

SERVICE MANUAL MODEL: 13512, 14412, 15312

SERVICE MANUAL MODEL: 13512, 14412, 15312 SERVICE MANUAL MODEL: 13512, 14412, 15312 CONTENTS TROUBLESHOOTING... 1-3 SERVICE ACCESS (1) FACE COVER, BELT COVER... 4 SERVICE ACCESS (2) BASE PLATE... 5 SERVICE ACCESS (3) FRONT COVER... 6 SERVICE ACCESS

More information

DLN ENGINEER S MANUAL

DLN ENGINEER S MANUAL High-speed, 1-needle, Cylinder-bed, Needle-feed, Lockstitch Machine with Large Hook DLN-6390 High-speed, 1-needle, Cylinder-bed, Needle-feed, Lockstitch Machine with Automatic Thread Trimmer and Large

More information

MTY (81)

MTY (81) This manual describes the option "e" of the SMT-BD1 amplifier: Master/slave tension control application. The general information about the digital amplifier commissioning are described in the standard

More information

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany Technical manual Microstep driver NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D-85652 Landsham near Munich, Germany Tel. +49 (0)89-900 686-0 Fax +49 (0)89-900 686-50 info@nanotec.de Editorial Editorial

More information

Industrial motor controller for brushed DC motors 12 VDC

Industrial motor controller for brushed DC motors 12 VDC Industrial motor controller for brushed DC motors 12 VDC Design for output currents up to 5 A Control with the following functions: - reversal of direction of rotation - rotational speed control (external)

More information

First published : May 1997 Fourth edition : January No

First published : May 1997 Fourth edition : January No First published : May 1997 Fourth edition : January 2006 No. 050153 INTRODUCTION Thank you for your purchasing Kansai Special's FX Series. Read and study this instruction manual carefully before beginning

More information

Cover Stitch Wide. Cover Stitch Looper Thread. Cover Stitch Wide page 1

Cover Stitch Wide. Cover Stitch Looper Thread. Cover Stitch Wide page 1 Cover Stitch Wide Cover Stitch Wide This professional Cover Hem stitch is a necessary requirement for today s sewing. The stitch is often seen in ready-to-wear garments. Two needles create parallel rows

More information

High-speed, 1-needle, Cylinder-bed, Needle-feed, Lockstitch Machine with Large Hook

High-speed, 1-needle, Cylinder-bed, Needle-feed, Lockstitch Machine with Large Hook R High-speed, 1-needle, Cylinder-bed, Needle-feed, Lockstitch Machine with Large Hook DLN-6390 High-speed, 1-needle, Cylinder-bed, Needle-feed, Lockstitch Machine with Automatic Thread Trimmer and Large

More information

Top Innovations, Inc. Innovative Products to Make Your Life Easier. Model SP-402 Owner s Manual

Top Innovations, Inc. Innovative Products to Make Your Life Easier. Model SP-402 Owner s Manual Top Innovations, Inc. Innovative Products to Make Your Life Easier Model SP-402 Owner s Manual THIS IS NOT A TOY! Adult supervision recommended Item contains sharp functional points and small parts Machine

More information

BERNINA. Overlocker Workbook 2

BERNINA. Overlocker Workbook 2 Overlocker Plus For current BERNINA models 2016 BERNINA of America. Permission granted to copy and distribute in original form only. Content may not be altered or used in any other form or under any other

More information

Replacing the Reciprocator on the SWF Compact Series Machine (601C and 1201C)

Replacing the Reciprocator on the SWF Compact Series Machine (601C and 1201C) Follow the instructions below to replace the reciprocator in the SWF Compact series machines. The tools required can be found in the tool kit that came with the machine. Preparation 1. First, place the

More information

30AUTO Speed Lathe Manual

30AUTO Speed Lathe Manual 30AUTO Speed Lathe Manual Standard Features 3/4 HP Motor Air-Collet Closure 1800 RPM, Single Speed Electric Brake Cast Housing 5C Collets 3 Phase / 240 Volts DESCRIPTION: The Crozier Model 30AUTO Automotive

More information

the needle, the user must take sufficient care to avoid injury and observe the sewing area continuously while sewing.

the needle, the user must take sufficient care to avoid injury and observe the sewing area continuously while sewing. / - nstruct0fl maflua 7 the needle, the user must take the light bulb is 15 watts. agent. by anyone but an authorized Pfaff D) The drive belt must never be adjusted B) When leaving the machine, chan C)

More information

Motion Control. INFO-ACSr. AC Motor Controller 100% Digital. Technical Data

Motion Control. INFO-ACSr. AC Motor Controller 100% Digital. Technical Data Motion Control INFO-ACSr AC Motor Controller 100% Digital Technical Data Highly precise and very fast positioning and control tasks are implemented with the aid of the INFO-ACSr servo-controller. ACS servo-controllers

More information

Wind Transmitter First Class

Wind Transmitter First Class THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021310/07/06 Wind Transmitter First Class 4.3350.00.000 4.3350.10.000 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Electromotoric actuators

Electromotoric actuators s 4 540 ACVATIX Electromotoric actuators for Combi valves VPI45.., DN40/50 SQD65 operating voltage AC 230 V, 3-position control signal operating voltage AC 24 V, 3-position control signal SQD65 operating

More information

KWIKFOLD User Manual

KWIKFOLD User Manual KWIKFOLD User Manual English X2 1 2 3 4 5 7 X1 Ernst Nagel GmbH: Gebrauchsanleitung 2002-06-13 eng.doc 2/16 Introduction Your Foldnak 40 bookletmaker uses the Foldnak principle: stapling and folding in

More information

Single needle direct drive straight lock stitcher with thread trimmer. Single needle direct drive needle feed lock stitcher with thread trimmer

Single needle direct drive straight lock stitcher with thread trimmer. Single needle direct drive needle feed lock stitcher with thread trimmer Single needle direct drive straight lock stitcher S-7200B Single needle direct drive needle feed lock stitcher S-7220B Good response, comfortable sewing Clean sewing without oil staining User-friendly

More information

Serging Ahead For all current BERNINA serger models

Serging Ahead For all current BERNINA serger models 2 Serging Ahead For all current BERNINA serger models 2011 BERNINA of America, Inc. Permission granted to copy and distribute in original form only. Content may not be altered or used in any other form

More information

Operator's manual. TruTool N 200 (1A1) english

Operator's manual. TruTool N 200 (1A1) english Operator's manual TruTool N 200 (1A1) english Table of contents 1. Safety...3 2. Description...5 2.1 Correct use...6 2.2 Technical data...7 3. Tool assembly...8 3.1 Changing the stroke rate...8 4. Operation...10

More information

Operating Instructions

Operating Instructions Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description

More information

Spindle moulder T 20 Tilting arbor spindle moulder T 26

Spindle moulder T 20 Tilting arbor spindle moulder T 26 Sägen Hobeln Fräsen Otto Martin Maschinenbau GmbH & Co. KG Langenberger Str. 6 87724 Ottobeuren / Germany Spindle moulder T 20 Tilting arbor spindle moulder T 26 Phone: +49 (0) 83 32 / 911-0 Fax: +49 (0)

More information

Four-Thread Safety Stitch

Four-Thread Safety Stitch Four-Thread Safety Stitch Four-Thread Safety Stitch This stitch is an alternative to the Five-Thread Safety Stitch. It offers the same type of Two-Thread Chainstitch. However the Three-Thread Overlock

More information

Please enter the identity code of your device here!

Please enter the identity code of your device here! Operating Instructions DULCOMETER D1C Part 2: Adjustment and Operation, Measured Variable Conductive Conductivity ProMinent D1C2-Leit.-001-GB Conductivity 100 µs/cm DULCOMETER STOP START Conductivity 100

More information

BECS-C19. ( For Chenille/Looping Embroidery) OWNER S MANUAL.

BECS-C19. ( For Chenille/Looping Embroidery) OWNER S MANUAL. BECS-C19 ( For Chenille/Looping Embroidery) Version:2012-01 OWNER S MANUAL www.butterflyemb.com Index Index 1 Introduction Of Functions... 1 2 Shift Between Looping Head & Lockstitch Head... 1 2.1 Shift

More information

Transformer Winding Machine Controller (CNC-07SG)

Transformer Winding Machine Controller (CNC-07SG) AN ISO 9001:2008 CERTIFIED COMPANY Transformer Winding Machine Controller (CNC-07SG) USER MANUAL DISCLAIMER The information provided in this document is believed to be reliable. However, no responsibility

More information

Instruction manual SUN-PM100L. SUN-PM100L Polishing Machine English

Instruction manual SUN-PM100L. SUN-PM100L Polishing Machine English Instruction manual SUN-PM100L SUN-PM100L Polishing Machine English Table: SUN-UM-TL-PM001 Version: A/0 Fiber Optic Solutions Provider Ⅰ Safety Precautions To ensure safe operation and maximize product

More information

Union Jack Variation Free Pattern Approximately 75-3/8 x 57

Union Jack Variation Free Pattern Approximately 75-3/8 x 57 Paper Pieces P.O. Box 68 Sycamore, IL 60178 Paper Pieces Precut Paper Shapes for English Paper Piecing 1-800-337-1537 US ONLY 1-815-899-0925 1-815-899-2900 Fax or Direct Line Union Jack Variation Free

More information

MTY (81)

MTY (81) This manual describes the option "d" of the SMT-BD1 amplifier: Master/slave electronic gearing. The general information about the digital amplifier commissioning are described in the standard SMT-BD1 manual.

More information

SFP-550. Operating Manual MATSUHIDAI, MATSUDO-CITY, CHIBA JAPAN TEL: FAX:

SFP-550. Operating Manual MATSUHIDAI, MATSUDO-CITY, CHIBA JAPAN TEL: FAX: SFP-550 Operating Manual 296-1 MATSUHIDAI, MATSUDO-CITY, CHIBA 270-2214 JAPAN TEL: +81-47-388-6111 FAX: +81-47-388-4477 Safety Precautions To ensure safe operation and maximize product service life, observe

More information

Sew Beautiful. with Kirei NX7 JUKI: SEWING MACHINES WITH HISTORY

Sew Beautiful. with Kirei NX7 JUKI: SEWING MACHINES WITH HISTORY Sew Beautiful with Kirei N7 JUKI: SEWING MACHINES WITH HISTORY Since their introduction in 1947, JUKI s home sewing machines have been a brand loved around the world. JUKI's home sewing machines contain

More information

DDL-9000C-F INSTRUCTION MANUAL

DDL-9000C-F INSTRUCTION MANUAL DDL-9000C-F INSTRUCTION MANUAL CONTENTS 1. SPECIFICATIONS... 1 1-1. Specifications of the sewing machine head... 1 1-2. Specifications of the control box... 1 2. SET UP... 2 2-1. Drawing of table... 2

More information

LZ-2290A-SR-7 LZ-2290A-SR-7-WB

LZ-2290A-SR-7 LZ-2290A-SR-7-WB LZ-2290A-SR-7 LZ-2290A-SR-7-WB The machine is built around the newly developed LZ-2290A-7 machine head. In addition to the conventional types of stitching, the machine is able to perform T-shape stitching

More information

KE 436 B Electronic Lockstitch Pattern Tacker with Stepping Foot and Programming function

KE 436 B Electronic Lockstitch Pattern Tacker with Stepping Foot and Programming function KE 436 B Electronic Lockstitch Pattern Tacker with Stepping Foot and Programming function Specifications Stitch formation Maximum sewing speed Maximum pattern size (X x Y) Feed mechanism Stitch length

More information

CAUTION- SAVE THESE INSTRUCTIONS This product is for household use, or equivalent.

CAUTION- SAVE THESE INSTRUCTIONS This product is for household use, or equivalent. Never operate this sewing machine if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, dropped into water. Return this sewing machine to the nearest authorized

More information

Operation Manual GF MH/L38 GF MH/L38 GF MH/L38 GF MH/L38

Operation Manual GF MH/L38 GF MH/L38 GF MH/L38 GF MH/L38 Operation Manual GF-137-443 MH/L38 GF-137-448 MH/L38 GF-237-443 MH/L38 GF-237-448 MH/L38 ANITA B, s.r.o. Průmyslová 2453/7 680 01 Boskovice Czech Republic tel: +420 516 454 774 fax: +420 516 452 751 e-mail:

More information

HQ Hideaway. Installation and Operation Version 2.2, April 2015 Part # QT40100

HQ Hideaway. Installation and Operation Version 2.2, April 2015 Part # QT40100 HQ Hideaway Installation and Operation Version 2.2, April 2015 Part # QT40100 Copyright 2015 Handi Quilter, Inc. All rights reserved. Printed in the U.S.A. Table of Contents Page Overview 3 To install

More information

GS1 Parameter Summary Detailed Parameter Listings...4 9

GS1 Parameter Summary Detailed Parameter Listings...4 9 CHAPTER AC DRIVE 4 PARAMETERS Contents of this Chapter... GS1 Parameter Summary...............................4 2 Detailed Parameter Listings..............................4 9 Motor Parameters.........................................4

More information

LH-4100 series LH-4128 / LH / LH / LH Semi-dry-head, Direct-drive, High-speed, 2-needle, Needle-feed, Lockstitch Machine

LH-4100 series LH-4128 / LH / LH / LH Semi-dry-head, Direct-drive, High-speed, 2-needle, Needle-feed, Lockstitch Machine LH-4100 series LH-4128 / LH-4128-7 / LH-4168-7 / LH-4188-7 emi-dry-head, Direct-drive, High-speed, 2-needle, Needle-feed, Lockstitch Machine LH-4100 series Even when the sewing material is changed or even

More information

BLD75-1. Bilevel Step Motor Driver. User s Guide. #L010125

BLD75-1. Bilevel Step Motor Driver. User s Guide.   #L010125 BLD75-1 Bilevel Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N #L010125 1 Features Unipolar Operation 10 Amps per Phase Operating Current (Kick Current) 7 Amps per Phase Standstill Current

More information

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B PEAKTRONICS The Peaktronics AC Motor Controller is a compact module that is intended for controlling small AC actuator motors of up to 2A. The is very well suited for applications where space constraints

More information

NAMES OF PARTS. 1 Thread guide for bobbin winding 2 Take-up lever. 3 Upper thread tension dial. 4 Face cover. 5 Thread guide for upper threading

NAMES OF PARTS. 1 Thread guide for bobbin winding 2 Take-up lever. 3 Upper thread tension dial. 4 Face cover. 5 Thread guide for upper threading 6 Presser foot thumb screw 9 Spool pins (retractable) 8 Shuttle cover 5 Thread guide for upper threading 7 Presser foot 4 Face cover NAMES OF PARTS.r4r : VjN S* ;WWE7-17 16 15 MODEL 860.-.-.- --. :.---.-

More information

Bead Roller Operating, Servicing, and Safety Instruction Manual

Bead Roller Operating, Servicing, and Safety Instruction Manual Bead Roller Operating, Servicing, and Safety Instruction Manual CAUTION: Read and Understand These Operating, Servicing, and Safety Instructions, Before Using This Machine. 1-800-67-26 10 Cooperative Way

More information

Computer-controlled, High-speed, Lockstitch Buttonholing Machine LBH-1790 LBH-1790S

Computer-controlled, High-speed, Lockstitch Buttonholing Machine LBH-1790 LBH-1790S Computer-controlled, High-speed, Lockstitch Buttonholing Machine LBH-1790 LBH-1790S LBH-1790 The machine offers increased flexibility. It achieves the highest productivity and seam quality. The machine

More information

5000 Series Receiver Systems

5000 Series Receiver Systems 5000 Series Receiver Systems Modular multi-channel receiver system for demanding musical and broadcast applications Large mainframe houses up to 8 true diversity receiver modules Small mainframe houses

More information

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers The Indelac / AC Motor Controllers are used for proportional positioning of split phase AC actuator motors. An external command signal of 0-0V, -V, or -0mA can be used to compare to a feedback signal from

More information

DT3-B291 Cylinder Bed Needle Feed Double Chain Stitcher

DT3-B291 Cylinder Bed Needle Feed Double Chain Stitcher DT3-B291 Cylinder Bed Needle Feed Double Chain Stitcher Specifications DT3 - B291-060 - No. of needles & Needle gauge 7 Twin needle, 31.8 mm (1 1/4) 8 Twin needle, 34.9 mm (1 3/8) A 4 needle, 6.4-25.4-6.4

More information

MF-7524 INSTRUCTION MANUAL

MF-7524 INSTRUCTION MANUAL MF-7524 INSTRUCTION MANUAL 1 CONTENTS Ⅰ. SPECIFICATIONS...1 Ⅱ. CONFIGURATION OF THE MACHINE COMPONENTS...2 Ⅲ. INSTALLATION... 3 1. Installing the machine head onto the table...3 2. Selecting the motor

More information

Analog-to-Digital-Converter User Manual

Analog-to-Digital-Converter User Manual 7070 Analog-to-Digital-Converter User Manual copyright FAST ComTec GmbH Grünwalder Weg 28a, D-82041 Oberhaching Germany Version 2.0, July 7, 2005 Software Warranty FAST ComTec warrants proper operation

More information

Spezialnähmaschine. Betriebsanleitung. Instruction manual. Instructions d emploi

Spezialnähmaschine. Betriebsanleitung. Instruction manual. Instructions d emploi 867 Spezialnähmaschine Betriebsanleitung Instruction manual Instructions d emploi D GB F Postfach 17 03 51, D-33703 Bielefeld Potsdamer Straße 190, D-33719 Bielefeld Telefon +49 (0) 521 / 9 25-00 Telefax

More information

To install new top weight plate bushings in G7 strength units.

To install new top weight plate bushings in G7 strength units. 1/5 PURPOSE To install new top weight plate bushings in G7 strength units. RE-WORK PARTS REQUIRED - ZMS4000424 Top Weight Plate Bushing (Quantity 4 per machine). - Matrix Top Weight Plate Bushing Removal

More information

ESR. The Dynamic Solution. Applications. Products, Consultation, and Service. ESR Pollmeier GmbH

ESR. The Dynamic Solution. Applications. Products, Consultation, and Service. ESR Pollmeier GmbH Analog AC servo drive systems with sinusoidal commutation Servo drives in compact design, 230 V AC mains connection Servo motors with high power density up to 5.0 Nm / 1.1 kw Components of the TrioDrive

More information

DU INSTRUCTION MANUAL

DU INSTRUCTION MANUAL DU-1281-7 INSTRUCTION MNUL CONTENTS 1. SPECIFICTIONS... 1 2. PREPRTION EFORE OPERTION... 2 2-1. Installing the knee lifter... 2 2-2. Installing the waste oil receiver... 2 2-3. Lubrication... 3 2-4. Oiling

More information