STATUS REPORT OF TIME AND FREQUENCY LAB. (VIETNAM METROLOGY INSTITUTE)

Size: px
Start display at page:

Download "STATUS REPORT OF TIME AND FREQUENCY LAB. (VIETNAM METROLOGY INSTITUTE)"

Transcription

1 STATUS REPORT OF TIME AND FREQUENCY LAB. (VIETNAM METROLOGY INSTITUTE) Trieu Viet Phuong Head of Time and Frequency Laboratory, VMI DA NANG

2 About TFL Laboratory of time and frequency (TFL) is belonging to VMI. The Lab is a highest laboratory in the fields of Time and frequency in Vietnam testing measurement calibration scheme. There are 7 staffs working at the TFL. The laboratory has been accredited in accordance with ISO/IEC 17025:2005 by Vietnam Laboratory Accreditation Scheme (VILAS). 2

3 T&F activities Time keeping. Time transfer. Time and frequency disseminations: Calibration and testing services; Internet time service. Researching, designing, manufacturing. Other activities. 3

4 Time keeping TFL operates three cesium atomic clocks (one of them is high performance cesium beam tube, 5071A with Option 001). UTC(VMI) and VFS are generated from the high performance cesium clock and Auxiliary Output Generator, AOG-110. Three atomic clocks have been compared with one another by the TSC This comparison is performed daily at UTC 0 h (UTC(VMI) + 7 h). The data collected for one month are sent to the BIPM time section. Time and Frequency system at VMI 4

5 UTC-UTC(VMI) Time keeping UTC(VMI) = UTC + 7 h. UTC - UTC(VMI) < 100 ns, Uncertainty ~ 20.1 ns MJD UTC UTC(VMI) from January to September

6 Time transfer: TAI time link GPS receivers (Javad EU-80 and Septentrio Polarx3e TR) for TAI time comparison network. The GPS observations are measured daily. 6

7 Time transfer: TAI time link Output files in the format of CGGTTS are sent to BIPM monthly. Output files in the RINEX (from Septentrio PolaR3eTr) is sent to BIPM daily. 7

8 Internet time service TFL provided NTP service using time server S250i. TFL internet time service uses UTC(VMI) as a reference time. TFL also contributes to standardization of Time Stamping Service (the clock of the time stamping server is calibrated within the prescribed accuracy and traceability to UTC(VMI) for every issued time stamp is assured). Can accept up to requests per second. 8

9 Calibration and testing services VMI has been conducting a frequency calibration service referenced to UTC(VMI). The first CMC table was approved and registered in the Key Comparison Database (KCDB). 9

10 Calibration and testing services Total number: > 300 units/ yearly, included: Universal counters, Signal generators, Local clocks, Quartz oscillators, local frequency standards, Type approval test for taximeters, Automobiles tachograph (GPS tracker, car black box) 10

11 Researching, designing, manufacturing Researching, designing, manufacturing some equipment such as: power cut/ on warning via SMS system; tachometer; standard for verification of taximeters, and NTP clocks Development of new algorithm and software for steering and keeping of UTC(VMI). 11

12 Other activities To develop calibration/ verification testing methods. To carry out peer review on the technical aspects of verification bodies, serving the state management on Time and frequency metrology. To develop material for trainings on Time and frequency metrology. To train the technical staffs for the verification, calibration and testing bodies in time and frequency field 12

13 Future plans To plan for Cesium Beam Tube Replacement (in 2017). To build dual system to generate of UTC(VMI) (after 2017 to 2020). To develop remote calibration services, strengthen international and bilateral comparison with other NMIs. To expand TF s CMC table (after 2017). 13

14 Thank you for your attention! 14

REPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE)

REPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE) Trieu Viet Phuong Deputy head of Time and Frequency Laboratory (TFL) Vietnam Metrology Institute (VMI) N 0 8, Hoang Quoc Viet Road, Caugiay District, Hanoi, Vietnam About Time & Frequency Laboratory (TFL)

More information

REPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE)

REPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE) Nguyen Bang Head of Time and Frequency Laboratory (TFL) Vietnam Metrology Institute (VMI) N 0 8, Hoang Quoc Viet Road, Caugiay District, Hanoi, Vietnam About Time & Frequency Laboratory (TFL) Time and

More information

Activity Report of Time and Frequency Laboratory, NMIM (formally known as NML-SIRIM), Malaysia

Activity Report of Time and Frequency Laboratory, NMIM (formally known as NML-SIRIM), Malaysia Activity Report of Time and Frequency Laboratory, NMIM (formally known as NML-SIRIM), Malaysia Dr. Mohd. Nasir Senior Principal Metrologist Ahmad Sahar Senior Metrologist Mohd Rafiq Metrologist Mohd Izzulfitri

More information

Mongolian Agency for Standardization and Metrology Time Frequency Lab. Unurbileg Darmaa Head, Length & Time and Frequency lab MASM

Mongolian Agency for Standardization and Metrology Time Frequency Lab. Unurbileg Darmaa Head, Length & Time and Frequency lab MASM Mongolian Agency for Standardization and Metrology Time Frequency Lab Unurbileg Darmaa Head, Length & Time and Frequency lab MASM 2017-10-26 11/13/2017 Mongolian Agency for Standardization and Metrology

More information

Traceability measurement results of accurate time and frequency in Bosnia and Herzegovina

Traceability measurement results of accurate time and frequency in Bosnia and Herzegovina INFOTEH-JAHORINA Vol. 11, March 2012. Traceability measurement results of accurate time and frequency in Bosnia and Herzegovina Osman Šibonjić, Vladimir Milojević, Fatima Spahić Institute of Metrology

More information

Time and Frequency Laboratory Measurement Units, Standards and Services Department (National Metrology Institute) MUSSD- Sri Lanka

Time and Frequency Laboratory Measurement Units, Standards and Services Department (National Metrology Institute) MUSSD- Sri Lanka Time and Frequency Laboratory Measurement Units, Standards and Services Department (National Metrology Institute) MUSSD- Sri Lanka Introduction Measurement Units, Standards and Services Department (MUSSD

More information

Time and Frequency Research Activity in NIM

Time and Frequency Research Activity in NIM Time and Frequency Research Activity in NIM Gao Xiaoxun National Institute of Metrology Bei San Huan Dong Lu No.18 Beijing P.R.China Abstract This paper will introduce scientific research activities in

More information

Time and Frequency Laboratory Measurement Units, Standards. (National Metrology Institute) MUSSD-Sri Lanka

Time and Frequency Laboratory Measurement Units, Standards. (National Metrology Institute) MUSSD-Sri Lanka Time and Frequency Laboratory Measurement Units, Standards and Services Department (National Metrology Institute) MUSSD-Sri Lanka Introduction Measurement Units, Standards and Services Department (MUSSD

More information

METAS TIME & FREQUENCY METROLOGY REPORT

METAS TIME & FREQUENCY METROLOGY REPORT METAS TIME & FREQUENCY METROLOGY REPORT Laurent-Guy Bernier METAS Federal Office of Metrology Lindenweg 50, Bern-Wabern, Switzerland, CH-3003 E-mail: laurent-guy.bernier@metas.ch, Fax: +41 31 323 3210

More information

LITHUANIAN NATIONAL TIME AND FREQUENCY STANDARD

LITHUANIAN NATIONAL TIME AND FREQUENCY STANDARD LITHUANIAN NATIONAL TIME AND FREQUENCY STANDARD Rimantas Miškinis Semiconductor Physics Institute A. Goštauto 11, Vilnius 01108, Lithuania Tel/Fax: +370 5 2620194; E-mail: miskinis@pfi.lt Abstract The

More information

CURRENT ACTIVITIES OF THE NATIONAL STANDARD TIME AND FREQUENCY LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT TELECOM CO., LTD.

CURRENT ACTIVITIES OF THE NATIONAL STANDARD TIME AND FREQUENCY LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT TELECOM CO., LTD. CURRENT ACTIVITIES OF THE NATIONAL STANDARD TIME AND FREQUENCY LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT TELECOM CO., LTD., TAIWAN C. S. Liao, P. C. Chang, and S. S. Chen National Standard

More information

Haruo Saito. National Institute of Information and Communications Technology

Haruo Saito. National Institute of Information and Communications Technology Calibration system at NICT Haruo Saito National Institute of Information and Communications Technology Organization of NICT Content Calibration system Calibration system Carried in system and remote system

More information

Time and frequency transfer methods based on GNSS. LIANG Kun, National Institute of Metrology(NIM), China

Time and frequency transfer methods based on GNSS. LIANG Kun, National Institute of Metrology(NIM), China Time and frequency transfer methods based on GNSS LIANG Kun, National Institute of Metrology(NIM), China Outline Remote time and frequency transfer GNSS time and frequency transfer methods Data and results

More information

MEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA PRESENTED BY: R.G.S.A. PERERA

MEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA PRESENTED BY: R.G.S.A. PERERA MEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA PRESENTED BY: R.G.S.A. PERERA SRI LANKA Government type: Democratic Socialist Republic Capital city: Sri Jayawardenapura Location: South

More information

TIME AND FREQUENCY ACTIVITIES AT THE CSIR NATIONAL METROLOGY LABORATORY

TIME AND FREQUENCY ACTIVITIES AT THE CSIR NATIONAL METROLOGY LABORATORY TIME AND FREQUENCY ACTIVITIES AT THE CSIR NATIONAL METROLOGY LABORATORY E. L. Marais and B. Theron CSIR National Metrology Laboratory PO Box 395, Pretoria, 0001, South Africa Tel: +27 12 841 3013; Fax:

More information

Outline. Introduction Laboratory Status Activities Future Plans

Outline. Introduction Laboratory Status Activities Future Plans Laboratory Report Time and Frequency Metrology Sub Division Research Center for Metrology Indonesian Institute of Sciences RCM LIPI Metrology Enabling Developing Economies in Asia, MEDEA Project for GPS

More information

NPLI Report. for. Technical workshop and inter-laboratory comparison exercise for GPS time-transfer and calibration techniques under MEDEA

NPLI Report. for. Technical workshop and inter-laboratory comparison exercise for GPS time-transfer and calibration techniques under MEDEA NPLI Report for Technical workshop and inter-laboratory comparison exercise for GPS time-transfer and calibration techniques under MEDEA Dr. V. N. Ojha, Dr. A. Agarwal, Mrs. D. Chaddha, Dr. S. Panja, Dr.

More information

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY Approved By: Chief Executive Officer: Ron Josias Senior Manager: Mpho Phaloane Revised By: Specialist Technical Committee

More information

THE TIMING ACTIVITIES OF THE NATIONAL TIME AND FREQUENCY STANDARD LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT CO. LTD.

THE TIMING ACTIVITIES OF THE NATIONAL TIME AND FREQUENCY STANDARD LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT CO. LTD. THE TIMING ACTIVITIES OF THE NATIONAL TIME AND FREQUENCY STANDARD LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT CO. LTD., TAIWAN P. C. Chang, J. L. Wang, H. T. Lin, S. Y. Lin, W. H. Tseng, C. C.

More information

TIME & FREQUENCY SERVICES IN MALAYSIA

TIME & FREQUENCY SERVICES IN MALAYSIA TIME & FREQUENCY SERVICES IN MALAYSIA Presented by : Mohd Rafiq Bin Abdul Kamal Metrologist National Metrology Laboratory SIRIM Berhad, Malaysia Time & Frequency Laboratory National Metrology Laboratory

More information

Certificate of Calibration No

Certificate of Calibration No Federal Department of Justice olice FDJP Federal Office of Metrology METAS Certificate of Calibration No 7-006 Object GPS rcvr type Septentrio PolaRx4TR PRO serial 005 Antenna type Aero AT-675 serial 500

More information

MEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA

MEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA COUNTRY REPORT: MEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA PRESENTED BY: R.G.S.ANURADHA. PERERA SRI LANKA Government type: Democratic Socialist Republic Location: South Asia,

More information

Status Report on Time and Frequency Activities at CSIR-NPL India

Status Report on Time and Frequency Activities at CSIR-NPL India Status Report on Time and Frequency Activities at CSIR-NPL India (APMP -TCTF 2016) S. Panja, A. Agarwal, D. Chadha, P. Arora, P. Thorat, S. De, S. Yadav, P. Kandpal, M. P. Olaniya and V. N. Ojha (Da Nang,

More information

Rapid UTC: a step forward for enhancing GNSS system times Elisa Felicitas Arias

Rapid UTC: a step forward for enhancing GNSS system times Elisa Felicitas Arias Rapid UTC: a step forward for enhancing GNSS system times Elisa Felicitas Arias Eighth Meeting of the International Committee on Global Navigation Satellite Systems (ICG) Dubai, United Arab Emirates 9-14

More information

Nov.6-7,2014 DEC Workshop on Participation in Coordinated Universal Time. Aimin Zhang National Institute of Metrology (NIM)

Nov.6-7,2014 DEC Workshop on Participation in Coordinated Universal Time. Aimin Zhang National Institute of Metrology (NIM) Nov.6-7,2014 DEC Workshop on Participation in Coordinated Universal Time Aimin Zhang National Institute of Metrology (NIM) Introduction UTC(NIM) at old campus Setup of new UTC(NIM) Algorithm of UTC(NIM)

More information

Status Report on Time and Frequency Activities at National Physical Laboratory India

Status Report on Time and Frequency Activities at National Physical Laboratory India Status Report on Time and Frequency Activities at National Physical Laboratory India (TCTF 2015) Ashish Agarwal *, S. Panja. P. Arora, P. Thorat, S. De, S. Yadav, P. Kandpal, M. P. Olaniya, S S Rajput,

More information

Programme of work and budget for Plans for Time Department

Programme of work and budget for Plans for Time Department Programme of work and budget for 2013-2015 Plans for 2016-2019 Time Department Elisa Felicitas Arias 101 th Meeting of the CIPM, Session 1 BIPM, Sèvres, 8 June 2012 Programme of work 2013-2015 Continues

More information

Upgradation and Strengthening of National Time Scale of India

Upgradation and Strengthening of National Time Scale of India Upgradation and Strengthening of National Time Scale of India (ATF 2017) Ashish Agarwal, P. Thorat, M. P. Olaniya, S. Yadav, P. Kandpal, P. Arora, S. Panja, S. De, T. Bharadwaj, N. Sharma, S. Kazim, B.

More information

Expert Site Visit Report

Expert Site Visit Report Expert Site Visit Report Time and Frequency Metrology Sub Division Research Center for Metrology Indonesian Institute of Sciences RCM LIPI Metrology Enabling Developing Economies in Asia, MEDEA Project

More information

PRECISE RECEIVER CLOCK OFFSET ESTIMATIONS ACCORDING TO EACH GLOBAL NAVIGATION SATELLITE SYSTEMS (GNSS) TIMESCALES

PRECISE RECEIVER CLOCK OFFSET ESTIMATIONS ACCORDING TO EACH GLOBAL NAVIGATION SATELLITE SYSTEMS (GNSS) TIMESCALES ARTIFICIAL SATELLITES, Vol. 52, No. 4 DOI: 10.1515/arsa-2017-0009 PRECISE RECEIVER CLOCK OFFSET ESTIMATIONS ACCORDING TO EACH GLOBAL NAVIGATION SATELLITE SYSTEMS (GNSS) TIMESCALES Thayathip Thongtan National

More information

Federal Department of Justice and Police FDJP Federal Office of Metrology METAS. Measurement Report No

Federal Department of Justice and Police FDJP Federal Office of Metrology METAS. Measurement Report No Federal epartment of Justice olice FJP Federal Office of Metrology METAS Measurement Report No 9-0009 Object GPS receiver type Septentrio PolaRxeTR serial 05 Antenna type Aero AT-775 serial 5577 Cable

More information

CCTF 2012 Report on Time & Frequency activities at National Physical Laboratory, India (NPLI)

CCTF 2012 Report on Time & Frequency activities at National Physical Laboratory, India (NPLI) CCTF 2012 Report on Time & Frequency activities at National Physical Laboratory, India (NPLI) Major activities of the Time & Frequency division of NPLI in the last three years have been: 1. Maintenance

More information

BIPM TIME ACTIVITIES UPDATE

BIPM TIME ACTIVITIES UPDATE BIPM TIME ACTIVITIES UPDATE A. Harmegnies, G. Panfilo, and E. F. Arias 1 International Bureau of Weights and Measures (BIPM) Pavillon de Breteuil F-92312 Sèvres Cedex, France 1 Associated astronomer at

More information

INRIM TIME AND FREQUENCY LABORATORY: STATUS AND ONGOING ENHANCEMENT ACTIVITIES

INRIM TIME AND FREQUENCY LABORATORY: STATUS AND ONGOING ENHANCEMENT ACTIVITIES INRIM TIME AND FREQUENCY LABORATORY: STATUS AND ONGOING ENHANCEMENT ACTIVITIES Valerio Pettiti, Roberto Costa, Giancarlo Cerretto, Cedric Plantard, and Franco Cordara Istituto Nazionale di Ricerca Metrologica

More information

Report of the TC Time and Frequency. Ramiz Hamid TC-TF Chair, TÜBİTAK UME, Turkey

Report of the TC Time and Frequency. Ramiz Hamid TC-TF Chair, TÜBİTAK UME, Turkey Report of the TC Time and Frequency Ramiz Hamid TC-TF Chair, TÜBİTAK UME, Turkey Contents TC-TF meeting and T&F strategy EMRP Projects and future optical redefinition of the second Time scale generation

More information

DEC Workshop on Participation in Co-ordinated Universal Time

DEC Workshop on Participation in Co-ordinated Universal Time Report (Philippines) DEC Workshop on Participation in Co-ordinated Universal Time 6 7 November 2014 NIM, Beijing, China Sabino Paulo B. Leones, Jr. National Metrology Laboratory (NML) Industrial Technology

More information

Relative Calibration of the Time Transfer Link between CERN and LNGS for Precise Neutrino Time of Flight Measurements

Relative Calibration of the Time Transfer Link between CERN and LNGS for Precise Neutrino Time of Flight Measurements Relative Calibration of the Time Transfer Link between CERN and LNGS for Precise Neutrino Time of Flight Measurements Thorsten Feldmann 1,*, A. Bauch 1, D. Piester 1, P. Alvarez 2, D. Autiero 2, J. Serrano

More information

STABILITY AND ACCURACY OF THE REALIZATION OF TIME SCALE IN SINGAPORE

STABILITY AND ACCURACY OF THE REALIZATION OF TIME SCALE IN SINGAPORE 90th Annual Precise Time and Time Interval (PTTI) Meeting STABILITY AND ACCURACY OF THE REALIZATION OF TIME SCALE IN SINGAPORE Dai Zhongning, Chua Hock Ann, and Neo Hoon Singapore Productivity and Standards

More information

Designated Institutes participating in the CIPM MRA

Designated Institutes participating in the CIPM MRA Designated Institutes participating in the CIPM MRA Expectations and nomination form Version 1.2 Contents 1. Introduction... 1 2. Designated Institute in Appendix A of the KCDB... 2 2.1. Designation of

More information

STEERING UTC (AOS) AND UTC (PL) BY TA (PL)

STEERING UTC (AOS) AND UTC (PL) BY TA (PL) STEERING UTC (AOS) AND UTC (PL) BY TA (PL) J. Nawrocki 1, Z. Rau 2, W. Lewandowski 3, M. Małkowski 1, M. Marszalec 2, and D. Nerkowski 2 1 Astrogeodynamical Observatory (AOS), Borowiec, Poland, nawrocki@cbk.poznan.pl

More information

Time and Frequency Activities at NICT, Japan

Time and Frequency Activities at NICT, Japan Time and Frequency Activities at NICT, Japan Yasuhiro Koyama, Kuniyasu Imamura, Tsukasa Iwama, Shin'ichi Hama, Jun Amagai, Ryuichi Ichikawa, and Mizuhiko Hosokawa National Institute of Information and

More information

Establishing Traceability to UTC

Establishing Traceability to UTC White Paper W H I T E P A P E R Establishing Traceability to UTC "Smarter Timing Solutions" This paper will show that the NTP and PTP timestamps from EndRun Technologies Network Time Servers are traceable

More information

Relative calibration of ESTEC GPS receivers internal delays

Relative calibration of ESTEC GPS receivers internal delays Report calibration ESTEC 2012 V3 Physikalisch-Technische Bundesanstalt Fachbereich 4.4 Bundesallee 100 38116 Braunschweig Germany Relative calibration of ESTEC GPS receivers internal delays June 2013 Andreas

More information

Activity report from NICT

Activity report from NICT Activity report from NICT APMP 2013 / TCTF meeting 25-26 November, 2013 National Institute of Information and Communications Technology (NICT) Japan 1 1 Activities of our laboratory Atomic Frequency Standards

More information

ILAC input to CIPM MRA Review Workshop October 2015

ILAC input to CIPM MRA Review Workshop October 2015 ILAC input to CIPM MRA Review Workshop 13-14 October 2015 BIPM Sevres 13 October 2015 By Erik Oehlenschlaeger ILAC (DANAK) ILAC History ILAC first started as a conference in 1977 (Copenhagen) with the

More information

Activity report from NICT

Activity report from NICT Activity report from NICT APMP 2016 / TCTF meeting 14-15 November, 2016 National Institute of Information and Communications Technology (NICT) Japan 1 1 Space time standards laboratory Atomic Frequency

More information

ESTIMATING THE RECEIVER DELAY FOR IONOSPHERE-FREE CODE (P3) GPS TIME TRANSFER

ESTIMATING THE RECEIVER DELAY FOR IONOSPHERE-FREE CODE (P3) GPS TIME TRANSFER ESTIMATING THE RECEIVER DELAY FOR IONOSPHERE-FREE CODE (P3) GPS TIME TRANSFER Victor Zhang Time and Frequency Division National Institute of Standards and Technology Boulder, CO 80305, USA E-mail: vzhang@boulder.nist.gov

More information

Activity report from NICT

Activity report from NICT Activity report from NICT APMP 2017 / TCTF meeting 27-28 November, 2017 National Institute of Information and Communications Technology (NICT) Japan 1 1 Space time standards laboratory Atomic Frequency

More information

Bureau International des Poids et Mesures. International Recognition of NMI Calibration and Measurement Capabilities: The CIPM MRA

Bureau International des Poids et Mesures. International Recognition of NMI Calibration and Measurement Capabilities: The CIPM MRA Bureau International des Poids et Mesures International Recognition of NMI Calibration and Measurement Capabilities: The CIPM MRA Prof. Michael Kühne International School of Physics Enrico Fermi Metrology

More information

Laboratory Report National Institute of Information and Communications Technology (NICT), Japan. Section 1: Laboratory Related Matters

Laboratory Report National Institute of Information and Communications Technology (NICT), Japan. Section 1: Laboratory Related Matters 32 nd Asia Pacific Metrology Programme General Assembly 17-18 November 2016 Da Nang, Vietnam Laboratory Report National Institute of Information and Communications Technology (NICT), Japan Section 1: Laboratory

More information

HOW TO RECEIVE UTC AND HOW TO PROVE ACCURACY

HOW TO RECEIVE UTC AND HOW TO PROVE ACCURACY HOW TO RECEIVE UTC AND HOW TO PROVE ACCURACY Marc Weiss, Ph.D. Independent Consultant to Booz Allen Hamilton Weiss_Marc@ne.bah.com Innovation center, Washington, D.C. JANUARY 23, 2018 HOW DO YOU GET UTC

More information

Time Traceability for the Finance Sector Fact Sheet

Time Traceability for the Finance Sector Fact Sheet Time Traceability for the Finance Sector Fact Sheet Version 1.4 14 March 2016 NPL Management Ltd is a company registered in England and Wales No. 2937881 Registered Office: NPL Management Ltd, Hampton

More information

Timing-oriented Processing of Geodetic GPS Data using a Precise Point Positioning (PPP) Approach

Timing-oriented Processing of Geodetic GPS Data using a Precise Point Positioning (PPP) Approach 6 th Meeting of Representatives of Laboratories Contributing to TAI BIPM, 31 March 2004 Timing-oriented Processing of Geodetic GPS Data using a Precise Point Positioning (PPP) Approach Patrizia TAVELLA,

More information

INITIAL TESTING OF A NEW GPS RECEIVER, THE POLARX2, FOR TIME AND FREQUENCY TRANSFER USING DUAL- FREQUENCY CODES AND CARRIER PHASES

INITIAL TESTING OF A NEW GPS RECEIVER, THE POLARX2, FOR TIME AND FREQUENCY TRANSFER USING DUAL- FREQUENCY CODES AND CARRIER PHASES INITIAL TESTING OF A NEW GPS RECEIVER, THE POLARX2, FOR TIME AND FREQUENCY TRANSFER USING DUAL- FREQUENCY CODES AND CARRIER PHASES P. Defraigne, C. Bruyninx, and F. Roosbeek Royal Observatory of Belgium

More information

Joint ILAC CIPM Communication regarding the. Accreditation of Calibration and Measurement Services. of National Metrology Institutes.

Joint ILAC CIPM Communication regarding the. Accreditation of Calibration and Measurement Services. of National Metrology Institutes. Joint ILAC CIPM Communication regarding the Accreditation of Calibration and Measurement Services of National Metrology Institutes 7 March 2012 Authorship This document was prepared by the International

More information

The Multi-Mode Time Transfer Based on GNSS

The Multi-Mode Time Transfer Based on GNSS The Multi-Mode Time Transfer Based on GNSS Shuhong ZHAO, Haibo YUAN National Time Service Center of CAS, PR China 2017.11 The Content of Report ü Background ü Principle of GNSS CV Time Transfer ü Results

More information

CIPM and CCPR What are these organizations and how do they affect my testing results. Maria Nadal Photometry, Surface Color and Appearance NIST

CIPM and CCPR What are these organizations and how do they affect my testing results. Maria Nadal Photometry, Surface Color and Appearance NIST CIPM and CCPR What are these organizations and how do they affect my testing results Maria Nadal Photometry, Surface Color and Appearance NIST CIE USA Annual Meeting October 6-7, 2014 Calibration Laboratory

More information

Report to the 20th Meeting of CCTF Research Activities on Time and Frequency National Metrology Institute of Japan (NMIJ)/AIST

Report to the 20th Meeting of CCTF Research Activities on Time and Frequency National Metrology Institute of Japan (NMIJ)/AIST Report to the 20th Meeting of CCTF Research Activities on Time and Frequency National Metrology Institute of Japan (NMIJ)/AIST The National Metrology Institute of Japan (NMIJ) is responsible for almost

More information

THE NATIONAL TIME AND FREQUENCY SERVICE OF THE RUSSIAN FEDERATION

THE NATIONAL TIME AND FREQUENCY SERVICE OF THE RUSSIAN FEDERATION THE NATIONAL TIME AND FREQUENCY SERVICE OF THE RUSSIAN FEDERATION V. Krutikov Gosstandard of Russia, Moscow 119991, Russia V. Kostromin and N. Koshelyaevsky Institute of Metrology for Time and Space FGUP

More information

TIME COORDINATION THROUGHOUT THE AMERICAS VIA THE SIM COMMON-VIEW GPS NETWORK

TIME COORDINATION THROUGHOUT THE AMERICAS VIA THE SIM COMMON-VIEW GPS NETWORK TIME COORDINATION THROUGHOUT THE AMERICAS VIA THE SIM COMMON-VIEW GPS NETWORK Michael A. Lombardi a, Andrew N. Novick a, J. Mauricio Lopez R. b, Jean-Simon Boulanger c, Raymond Pelletier c, and Carlos

More information

Specific Accreditation Criteria Calibration ISO/IEC Annex. Electrical metrology

Specific Accreditation Criteria Calibration ISO/IEC Annex. Electrical metrology Specific Accreditation Criteria Calibration ISO/IEC 17025 Annex Electrical metrology January 2018 Copyright National Association of Testing Authorities, Australia 2014 This publication is protected by

More information

Status Report on Time and Frequency Activities at NPL India

Status Report on Time and Frequency Activities at NPL India Status Report on Time and Frequency Activities at NPL India (APMP TCTF 2013) A. Sen Gupta, A. Chatterjee, A. K. Suri, A. Agarwal, S. Panja P. Arora, S. De, P. Thorat, S. Yadav, P. Kandpal, M. P. Olaniya

More information

Report of Time and Frequency Activities at NICT

Report of Time and Frequency Activities at NICT Report of Time and Frequency Activities at NICT National Institute of Information and Communications Technology Koganei, Tokyo, Japan 1. Introduction At National Institute of Information and Communications

More information

THE DEVELOPMENT OF MULTI-CHANNEL GPS RECEIVERS AT THE CSIR - NATIONAL METROLOGY LABORATORY

THE DEVELOPMENT OF MULTI-CHANNEL GPS RECEIVERS AT THE CSIR - NATIONAL METROLOGY LABORATORY 32nd Annual Precise Time and Time Interval (PTTI) Meeting THE DEVELOPMENT OF MULTI-CHANNEL GPS RECEIVERS AT THE CSIR - NATIONAL METROLOGY LABORATORY E. L. Marais CSIR-NML, P.O. Box 395, Pretoria, 0001,

More information

Calibration schedule 2016/9/29

Calibration schedule 2016/9/29 Outline Time links calibration Equipment calibration NIM calibrator: Equipment, characteristics NIM calibrator: Operation Calibration campaign: Data and results 51 Calibration schedule 52 NTSC calibration

More information

5-2 Generating and Measurement System for Japan Standard Time

5-2 Generating and Measurement System for Japan Standard Time 5-2 Generating and Measurement System for Japan Standard Time HANADO Yuko, IMAE Michito, KURIHARA Noriyuki, HOSOKAWA Mizuhiko, AIDA Masanori, IMAMURA Kuniyasu, KOTAKE Noboru, ITO Hiroyuki, SUZUYAMA Tomonari,

More information

Remote Frequency Calibration Service at NMIJ

Remote Frequency Calibration Service at NMIJ Remote Frequency Calibration Service at NMIJ Case Example for APMP-WS 2014 Frequency Measurement Systems Section National Metrology Institute of Japan (NMIJ), AIST, JAPAN Content Introduction Overview

More information

Time and Frequency Activities at NICT, Japan

Time and Frequency Activities at NICT, Japan Time and Frequency Activities at NICT, Japan Yasuhiro Koyama, Kuniyasu Imamura, Tsukasa Iwama, Shin'ichi Hama, Jun Amagai, Ryuichi Ichikawa, Yuko Hanado, and Mizuhiko Hosokawa National Institute of Information

More information

Traceability in Time and Frequency Metrology

Traceability in Time and Frequency Metrology Traceability in Time and Frequency Metrology Michael A. Lombardi National Institute of Standards and Technology Time and Frequency Division 325 Broadway Boulder, CO 80303 United States of America (303)

More information

RECENT TIMING ACTIVITIES AT THE U.S. NAVAL RESEARCH LABORATORY

RECENT TIMING ACTIVITIES AT THE U.S. NAVAL RESEARCH LABORATORY RECENT TIMING ACTIVITIES AT THE U.S. NAVAL RESEARCH LABORATORY Ronald Beard, Jay Oaks, Ken Senior, and Joe White U.S. Naval Research Laboratory 4555 Overlook Ave. SW, Washington DC 20375-5320, USA Abstract

More information

CCTF 2012: Report of the Royal Observatory of Belgium

CCTF 2012: Report of the Royal Observatory of Belgium CCTF 2012: Report of the Royal Observatory of Belgium P. Defraigne, W. Aerts Royal Observatory of Belgium Clocks and Time scales: The Precise Time Facility (PTF) of the Royal Observatory of Belgium (ROB)

More information

33 rd Asia Pacific Metrology Programme General Assembly 30 November 1 December 2017 New Delhi, India

33 rd Asia Pacific Metrology Programme General Assembly 30 November 1 December 2017 New Delhi, India 33 rd Asia Pacific Metrology Programme General Assembly 30 November 1 December 2017 New Delhi, India Laboratory Report National Metrology Institute of Japan (NMIJ) National Institute of Advanced Industrial

More information

THE OPEN TRACEABLE TIME PLATFORM AND ITS APPLICATION IN FINANCE AND TELECOMMUNICATIONS. Michael J. Wouters. National Measurement Institute, Australia

THE OPEN TRACEABLE TIME PLATFORM AND ITS APPLICATION IN FINANCE AND TELECOMMUNICATIONS. Michael J. Wouters. National Measurement Institute, Australia THE OPEN TRACEABLE TIME PLATFORM AND ITS APPLICATION IN FINANCE AND TELECOMMUNICATIONS Michael J. Wouters National Measurement Institute, Australia E. Louis Marais National Measurement Institute, Australia

More information

Comparison of Cesium Fountain Clocks in Europe and Asia

Comparison of Cesium Fountain Clocks in Europe and Asia APMP/TCTF workshop 214,Daejeon, Korea Comparison of Cesium Fountain Clocks in Europe and Asia Aimin Zhang National Institute of Metrology(NIM) Sep.2,214 Outline Introduction Setup of PFS comparison Comparison

More information

Preparation of the Inter- Laboratories Comparison

Preparation of the Inter- Laboratories Comparison Preparation of the Inter- Laboratories Comparison Yi-Jiun Huang GPS time-transfer and calibration techniques Concluding Workshop, Taoyuan, Taiwan October 25-26, 2017 The Inter-Laboratories Comparison (ILC)

More information

RECENT ACTIVITIES IN THE FIELD OF TIME AND FREQUENCY IN POLAND

RECENT ACTIVITIES IN THE FIELD OF TIME AND FREQUENCY IN POLAND RECENT ACTIVITIES IN THE FIELD OF TIME AND FREQUENCY IN POLAND Jerzy Nawrocki Astrogeodynamical Observatory, Borowiec near Poznań, and Central Office of Measures, Warsaw, Poland Abstract The work of main

More information

MULTI-GNSS TIME TRANSFER

MULTI-GNSS TIME TRANSFER MULTI-GNSS TIME TRANSFER P. DEFRAIGNE Royal Observatory of Belgium Avenue Circulaire, 3, 118-Brussels e-mail: p.defraigne@oma.be ABSTRACT. Measurements from Global Navigation Satellite Systems (GNSS) are

More information

LONG-BASELINE TWSTFT BETWEEN ASIA AND EUROPE

LONG-BASELINE TWSTFT BETWEEN ASIA AND EUROPE LONG-BASELINE TWSTFT BETWEEN ASIA AND EUROPE M. Fujieda, T. Gotoh, M. Aida, J. Amagai, H. Maeno National Institute of Information and Communications Technology Tokyo, Japan E-mail: miho@nict.go.jp D. Piester,

More information

NMI's Role and Expertise in Synchronization Applications

NMI's Role and Expertise in Synchronization Applications NMI's Role and Expertise in Synchronization Applications Wen-Hung Tseng National Time and Frequency standard Lab, Telecommunication Laboratories, Chunghwa Telecom Co., Ltd., Taiwan APMP 2014 Time-transfer

More information

ABSOLUTE CALIBRATION OF TIME RECEIVERS WITH DLR'S GPS/GALILEO HW SIMULATOR

ABSOLUTE CALIBRATION OF TIME RECEIVERS WITH DLR'S GPS/GALILEO HW SIMULATOR ABSOLUTE CALIBRATION OF TIME RECEIVERS WITH DLR'S GPS/GALILEO HW SIMULATOR S. Thölert, U. Grunert, H. Denks, and J. Furthner German Aerospace Centre (DLR), Institute of Communications and Navigation, Oberpfaffenhofen,

More information

Today's Lecture. Clocks in a Distributed System. Last Lecture RPC Important Lessons. Need for time synchronization. Time synchronization techniques

Today's Lecture. Clocks in a Distributed System. Last Lecture RPC Important Lessons. Need for time synchronization. Time synchronization techniques Last Lecture RPC Important Lessons Procedure calls Simple way to pass control and data Elegant transparent way to distribute application Not only way Hard to provide true transparency Failures Performance

More information

RESULTS FROM TIME TRANSFER EXPERIMENTS BASED ON GLONASS P-CODE MEASUREMENTS FROM RINEX FILES

RESULTS FROM TIME TRANSFER EXPERIMENTS BASED ON GLONASS P-CODE MEASUREMENTS FROM RINEX FILES 32nd Annual Precise Time and Time Interval (PTTI) Meeting RESULTS FROM TIME TRANSFER EXPERIMENTS BASED ON GLONASS P-CODE MEASUREMENTS FROM RINEX FILES F. Roosbeek, P. Defraigne, C. Bruyninx Royal Observatory

More information

Time and Frequency Activities at KRISS

Time and Frequency Activities at KRISS Time and Frequency Activities at KRISS Dai-Hyuk Yu Center for Time and Frequency Metrology, Division of Physical Metrology Korea Research Institute of Standards and Science (KRISS) dhyu@kriss.re.kr Time

More information

Research Activities on Time and Frequency National Metrology Institute of Japan (NMIJ)/AIST

Research Activities on Time and Frequency National Metrology Institute of Japan (NMIJ)/AIST CCTF/12-13 Report to the 19th Meeting of CCTF Research Activities on Time and Frequency National Metrology Institute of Japan (NMIJ)/AIST The National Metrology Institute of Japan (NMIJ) is responsible

More information

Measurement of CNGS Muon Neutrinos Speed with Borexino: INRIM and ROA Contribution

Measurement of CNGS Muon Neutrinos Speed with Borexino: INRIM and ROA Contribution Measurement of CNGS Muon Neutrinos Speed with Borexino: INRIM and ROA Contribution Giancarlo Cerretto 1, Hector Esteban 2, Marco Pallavicini 3, Valerio Pettiti 1, Cedric Plantard 1, and Alessandro Razeto

More information

Internationally accepted framework for metrology

Internationally accepted framework for metrology Internationally accepted framework for metrology Andy Henson BIPM Working Groups The BIPM Bureau International des Poids et Measures the intergovernmental organization through which Member States act together

More information

2-5 Frequency Calibration

2-5 Frequency Calibration 2-5 Frequency SAITO Haruo, IWAMA Tsukasa, TSUCHIYA Shigeru, and KOYAMA Yasuhiro The Japan Standard Time (JST) and the Coordinated Universal Time (UTC(NICT)), which are constructed by National Institute

More information

THE NATIONAL TIME AND FREQUENCY SERVICE OF THE RUSSIAN FEDERATION

THE NATIONAL TIME AND FREQUENCY SERVICE OF THE RUSSIAN FEDERATION THE NATIONAL TIME AND FREQUENCY SERVICE OF THE RUSSIAN FEDERATION V. Krutikov Gosstandard of Russia, Moscow 119991, Russia V. Kostromin and N. Koshelyaevsky Institute of Metrology for Time and Space FGUP

More information

CCTF 2015: Report of the Royal Observatory of Belgium

CCTF 2015: Report of the Royal Observatory of Belgium CCTF 2015: Report of the Royal Observatory of Belgium P. Defraigne Royal Observatory of Belgium Clocks and Time scales: The Precise Time Facility (PTF) of the Royal Observatory of Belgium (ROB) contains

More information

Impact of multi-gnss on international timekeeping

Impact of multi-gnss on international timekeeping Impact of multi-gnss on international timekeeping Elisa Felicitas Arias and Wlodek Lewandowski 5th ICG Meeting Torino (Italy), 18-22 October 2010 Outline Time scale contruction, case of UTC Role of GNSS

More information

TIME STABILITY AND ELECTRICAL DELAY COMPARISON OF DUAL- FREQUENCY GPS RECEIVERS

TIME STABILITY AND ELECTRICAL DELAY COMPARISON OF DUAL- FREQUENCY GPS RECEIVERS TIME STABILITY AND ELECTRICAL DELAY COMPARISON OF DUAL- FREQUENCY GPS RECEIVERS A. Proia 1,2, G. Cibiel 1, and L. Yaigre 3 1 Centre National d Etudes Spatiales 18 Avenue Edouard Belin, 31401 Toulouse,

More information

Recent Calibrations of UTC(NIST) - UTC(USNO)

Recent Calibrations of UTC(NIST) - UTC(USNO) Recent Calibrations of UTC(NIST) - UTC(USNO) Victor Zhang 1, Thomas E. Parker 1, Russell Bumgarner 2, Jonathan Hirschauer 2, Angela McKinley 2, Stephen Mitchell 2, Ed Powers 2, Jim Skinner 2, and Demetrios

More information

Version 1.1 (01/2015) EURAMET e.v. Bundesallee 100 D Braunschweig Germany. Phone:

Version 1.1 (01/2015) EURAMET e.v. Bundesallee 100 D Braunschweig Germany.   Phone: Authorship and Imprint This document was developed by the EURAMET e.v. Authors: W. Schmid (EURAMET), M. Sega (INRIM, Italy, EURAMET TC-MC Chair), J. Drnovsek (MIRS/UL-FE/LMK, Slovenia, EURAMET Vice-Chairperson

More information

Borderline between CIPM MRA and testing activities

Borderline between CIPM MRA and testing activities Borderline between CIPM MRA and testing activities Michela Sega, EURAMET TC-MC Chair INRIM-Italy 7 th Meeting of the Focus Group on Facilitating National Metrology Infrastructure Development Zagreb, Croatia,

More information

Remote Time Calibrations via the NIST Time Measurement and Analysis Service

Remote Time Calibrations via the NIST Time Measurement and Analysis Service Remote Time Calibrations via the NIST Time Measurement and Analysis Service Michael A. Lombardi and Andrew N. Novick Abstract: The National Institute of Standards and Technology (NIST) now offers a new

More information

DEMETRA A Time Service Demonstrator Patrizia Tavella, INRIM Torino Italy on behalf of DEMETRA consortium

DEMETRA A Time Service Demonstrator Patrizia Tavella, INRIM Torino Italy on behalf of DEMETRA consortium This project has received funding from the European GNSS Agency under the European Union s Horizon 2020 research and innovation programme under grant agreement No 640658. DEMETRA A Time Service Demonstrator

More information

ANALYSIS OF ONE YEAR OF ZERO-BASELINE GPS COMMON-VIEW TIME TRANSFER AND DIRECT MEASUREMENT USING TWO CO-LOCATED CLOCKS

ANALYSIS OF ONE YEAR OF ZERO-BASELINE GPS COMMON-VIEW TIME TRANSFER AND DIRECT MEASUREMENT USING TWO CO-LOCATED CLOCKS ANALYSIS OF ONE YEAR OF ZERO-BASELINE GPS COMMON-VIEW TIME TRANSFER AND DIRECT MEASUREMENT USING TWO CO-LOCATED CLOCKS Gerrit de Jong and Erik Kroon NMi Van Swinden Laboratorium P.O. Box 654, 2600 AR Delft,

More information

Influence of GPS Measurements Quality to NTP Time-Keeping

Influence of GPS Measurements Quality to NTP Time-Keeping Influence of GPS Measurements Quality to NTP Time-Keeping Vukan Ogrizović 1, Jelena Gučević 2, Siniša Delčev 3 1 +381 11 3218 582, fax: +381113370223, e-mail: vukan@grf.bg.ac.rs 2 +381 11 3218 538, fax:

More information

Report of the GPS calibration trip among NIMT, NMIM, and VMI in 2017

Report of the GPS calibration trip among NIMT, NMIM, and VMI in 2017 Report of the GPS calibration trip among NIMT, NMIM, and VMI in 2017 Y. Huang, T. Chiu, H. Lin and C. Liao 2017 ATF, CSIR-NPL, India November 25, 2017 Calibration for time transfer UTC(k) UTC(j) GPS Receiver

More information

F6052 Universal Time Synchronizer

F6052 Universal Time Synchronizer F6052 Universal Time Synchronizer Doble Engineering Company March 2014 2013 Doble Engineering Company. All Rights Reserved 1 2013 Doble Engineering Company. All Rights Reserved History of Portable Time

More information