Honeywell. Overload protection is provided for the transformer. Large 38 VA transformer to power heatingcooling low voltage control systems.
|
|
- Branden Morris
- 5 years ago
- Views:
Transcription
1 Honeywell R829 FAN CENTER OR AT72H,J TRANS- FORMER (WTH APPROPRATE RELAY), PROVDES LOW VOLTAGE CONTROL OF LNE VOLTAGE FAN MOTORS AND AUX- LARY CRCUTS N HEATNG, COOLNG, OR HEATNG-COOLNG SYSTEMS. AT72H,J Transformer provides for addition of cooling at later date without expensive rewiring by simply plugging in an R8222 (/4 hp) or an R8228 ( hp) Switching Relay. Overload protection is provided for the transformer. Large 8 VA transformer to power heatingcooling low voltage control systems. Low voltage terminal board provides convenient connections for thermostat, and heating and cooling equipment control circuit wiring. o Mounts on standard 4 inch square junction box. Relay in R829 is mounted in a receptacle and can easily be replaced without disturbing wiring. R829, with completely enclosed relay, can be mounted in any indoor location without additional enclosure. Meets NEMA ST2-97 Standard Residential Controls-Class 2 Transformers, marked NEMA Type D. R.E. REV (.08)
2 TRADELNE MODELS TRADELNE models are selected and packaged to provide ease of stocking, ease of handling and maximum replacement value. TRADE LNE model specifications are the same as standard models. TRADEL NE models: hp fan application. R829A Fan Center spdt switching; 8 VA trans- R829H Fan Center spdt switching; 8 VA former. For single-speed or 2-speed fan transformer. For - or 2-speed, hp fan application. application. R829B Fan Center dpdt switching; 8 VA trans- Q6AOO7 Plate Mounted Relay Receptacle for former. For total comfort application with installing R8222 and R8228 relays on J-boxes. electronic air cleaner, humidifier and blower ncludes leadwires for dpdt relay, metal relay motor. cover, and labels for spst, spdt, and dpdt R829D Fan Center dpst switching; normally relays. A knockout allows mounting a SUPER open power pole, and normally open pilot TRADELNE AT72D transformer. See Table or duty pole; 8 VA transformer. For l-speed fan TRADELNE Catalog to order appropriate application with an auxiliary circuit. relay. R829G Fan Center spst switching; normally ADDTONAL FEATURES: TRADELNE pack with open pole; 8 VA transformer. For l-speed, cross reference label and special instruction sheet. STANDARD MODELS TABLE R829 MODEL SPECFCATONS R829 REPLACEMENT COMPONENTSa RELAY NPUT SEE FAN TRANSFORMER HORSE- SWTCHNG VOLTAGE WRNG CENTER AND RELAY POWER (V AC) DAGRAM RECEPTACLE R829A AT72H R8222B /4 Spdt Fig. 5 R829B AT72J R8222D /4 Dpdt Fig. 6 R829C AT72H R8222A /4 Spst r N.O. Contact Fig. 7 R829D AT72J R8222U /4 R829E AT 72J R8222F /4 Dpst, N.O. Power Contact, N.O. Pilot DutV Contact 20 or Dpst, N.O. Contact, N.C. Contact R829F AT72J R8222C /4 Dpst, both Contacts N.0. R829G AT72H R8228A lb Spst, N.O. Contact RR7WH AT R8228B lb Sr)dt aat72h,j and appropriate relay can be ordered separately. 208/240 bl hp at 20v ac; 2 hp at 240V ac. kfig. 8 Fig.9 Fig. 8 Fig. 7 Fig. 5 * (continued on page ) WHOLESALER OR YOUR DSTRBUTOR, REFER TO THE TRADE LNE CATALOG OR PRCE SHEETS FOR COMPLETE ORDERNG NUMBER, OR SPECFY-. Order number. 2. Transformer primary voltage.. Accessories, if required. F YOU HAVE ADDTONAL QUESTONS, NEED FURTHER NFORMATON, OR WOULD LKE TO COMMENT ON OUR PRODUCTS OR SERVCES, PLEASE WRTE OR PHONE:. YOUR LOCAL HONEYWELL RESDENTAL DVSON SALES OFFCE (CHECK WHTE PAGES OF PHONE DRECTORY). 2. RESDENTAL DVSON CUSTOMER SERVCE HONEYWELL NC., 885 DOUGLAS DRVE NORTH Ml NNEAPOLS, MNNESOTA (62) (N CANADA HONEYWELL CONTROLS LMTED, 740 ELLESMERE ROAD, SCARBOROUGH, ONTARO MP 2V9) NTERNATONAL SALES AND SERVCE OFFCES N ALL PRNCPAL CTES OF THE WORLD. 2
3 STANDARD MODELS: AT72H Plate-mounted Transformer-Relay Receptacle use when cooling will be added later. ncludes receptacle and leadwires for spst or spdt relay circuit; less R8222 or R8228 relay and relay cover. See Table to order appropriate relay. AT72J Plate-mounted Transformer-Relay Receptacle use when cooling will be added later. ncludes receptacle and leadwires for dpdt or dpst relay circuit; less R8222 or R8228 relay and relay cover. See Table to order appropriate relay. TRANSFORMER RATNGS: Power Rating 8 VA. Primary Voltage either 20 or 208/240V ac. Open Circuit Secondary Voltage 26 ~.5 volts. Overload Protection nternal. Voltage Frequency 50/60 Hz. CONTACT RATNGS: Contact ratings are for both normally open and normally closed contacts. R829A F. VOLTAGE 20V AC 240V AC Full Load (amp) Locked Rotor (amd) ,4 Horse~ower /4 /4 R829G and H. VOLTAGE 20V AC 240V AC Full Load (am~) 6 2 Locked Rotor (amp) Horsepower 2 RELAY COL RATNGS: nrush 20 VA maximum. Sealed-9 VA. Wattage 5 watts. Pickup Voltage must pick up below 8 volts. LEADWRE COLOR CODE: FG. 8 VA TRANSFORMER REGULATON CURVES. PLOT DUTY RATNGS FOR R829D PLC)T DUTY POLE: Minimum VA at 24, 20, 240, and 480V ac. Maximum 25 VA at 24V ac, 25 VA at 20, 240, and 480V ac. Resistive amps at 277V ac (0.75 power factor). Powerpile (millivoltage ) The normally open pilot duty contacts are rated for Powerpile (millivoltage) applications: 0.25 amp at 0.25 to 2V dc. TRANSFORMER PRMARY LEADWRE COLOR CODE : 20V Black and white. 208/240V black common: Red 208V. Orange 240V. MODEL SWTCHNG ] POLE LEADWRE COLOR Black common R829A Spdt Red N.O. contact AT72H Black common Red N O. contact R829B Dpdt AT72J Violet common Pole 2 Red/Yellow N.O. contact Yellow N.C. contact R829C %st R829D D pst (power pole) Pole 2 (pilot duty pole) Both leadwires red N.0. contact R829E Dpst Pole 2 Both leadwires red N.C. contact R829F Dpst Pole 2 Both leadwires red N.O. contact R829G Spst R829H Spdt Black common Red N. O. contact
4 ;79 LEADWRES: 9 inch color-coded leadwires. RELAY COL LEADWRE COLOR CODE: 2 blue leads connected to C and G terminals. POWER CONSUMPTON: 7.0 watts maximum. CONTACTS: Silver cadmium oxide. MOUNTNG: Mounts on standard 4 inch square junction box. DMENSONS: See Figs. 2 and. UNDERWRTERS LABORATORES NC. LSTED (for R829A-H): File No. E446, Guide No. XAPX. (R8222A-H): File No. E59779, Guide No. NLDX2. CANADAN STANDARDS ASSOCATON COMPO- NENT RECOGNZED: R829A-H File No. LR620. R8222 (all models) File No. LR5066. EXTERNAL LOAD: R829 and AT72H,J (with R8222 or R8228 relay) will operate the following typical Honeywell relay and/or contactor loads with up to 00 feet of No. 8 gauge wire (50 ft run). The maximum load for each application is: 2 R820 Switching Relays. 2 R850 Contractors. R820 Switching Relay and one R850 Cfmtactnr R850 Contactor and one R809 Thermal Delay Relay. R82O, R822, or R824 Contactor and one R820 Relay. R82O, R822, or R824 Contactor and one R809 Thermal Delay Relay. 4+ [4] t [20 5] [67) ; [86] 4r$l 06 7 =79,48. 2 APPROXMATE R829 AND AT72H WTH RELAY COVER NSTALLATON DMENSONS N NCHE [MLLMETRES]. 4; [4],, A :[86] %[ 06 ( - ;[86,4,,. FG. APPROXMATE AT72+,J NSTALLATON DMENsloNs N NCHES [M LLMETREs. 4
5 6 [62] 2;[57] ;[86] 4iz[ 06 TRANSFORMER L MOUNTNG HOLE (COVERED) ~DA. [22 _ FG. 4 APPROXMATE Q6Ao0 NSTALLATON DMENSONS N NCHES [Mi LLiMETREs]. MEETS NEMA ST2-97 RESDENTAL CONTROLS- an appropriate R8222 or R8228 relay into an AT72H,J CLASS 2 TRANSFORMER, classification marked tran~forrner. The wiring hookups are similar to Figs. 5-9 NEMA Type D. with the exception of some leadwire colors. Order the ACCESSORES: appropriate relay, using Table. The metal cover, Part The R829 function can be achieved by plugging No. 8705, is available to enclose the relay.. Disconnect power supply to prevent electrical shock and equipment damage. 2. nstaller must be a trained, experienced service technician.. Always conduct a thorough checkout when installation is complete. MOUNTNG The R829, AT72H,J and Q6AOO7 mount on a standard 4 inch square junction box. Make wiring connections in the junction box; then fasten the fan center to the box, placing the junction box screws through notches in the fan center mounting plate. On receptacles without relays, select and mount the appropriate relay (Table ) and attach the relay cover. A label identifying the relay used (furnished with TRADE LNE models) should be applied to the relay cover. NOTE: Relay may be mounted in any position. With the terminals pointing down, pickup voltage is increased by 2 percent. WRNG All wiring must comply with local codes and ordinances. Refer to information furnished with the system equipment or refer to Figs. 5-8 showing internal schematics and typical hookups for the fan centers. For R829F, see Fig. 8; for Q6AOO7, see Fig. 0. When making external connections to the line Underwriters Laboratories nc. listed connectors. ~ SOLATON RELAY ~ i [ : Ll----l PLENUM SWTCH OR OTHER SWTCHNG Al DEVCE ~RMARJ BROWN HEATNG CONTROL RED ~. R829A, H T, L J (l ~,!BLACK~,l[HOT)+ - TWO-SPEED FAN MOTOR [ ~ PROVDE DSCONNECT MEANS AND OVERLOAD PROTECTON AS REQuRED. ~ USE OPTONAL HOOKUP WTH SOLATNG RELAY (DASHED LNE) F HEATNG CONTROL HAS A SEPARATE PDWER suw.ly, SOLATON OF THE POWER SUPPLY MAY ALSO BE ACCOMPLSHED BY USNG SPECAL THERMOSTAT SUB. BASE COMBNATONS WTH SOLATED CRCUTS (SUCH AS T87F-QS9A 47, T84A.Q64A09, T822A.Q6 A07]. REFER TO SpeCifiCatiOn SHEETS FOR DETALS. G. 5 R829A,H TYPCAL HOOKUPWTH 2-SPEED FAN N HEATNG-COOLNG SYSTEM
Honeywell. Overload protection is provided for the transformer. Large 38 VA transformer to power heatingcooling low voltage control systems.
Honeywell R8239 CENTER OR AT72H,J TRANS- FORMER (WTH APPROPRATE RELAY), PROVDES LOW VOLTAGE CONTROL OF LNE VOLTAGE MOTORS AND AUX- LARY CRCUTS N HEATNG, COOLNG, OR HEATNG-COOLNG SYSTEMS. AT72H,J Transformer
More informationGeneral Purpose Relays Types K, R, N, and C
General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in
More informationTop wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations
Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching
More informationOPEN STYLE POWER RELAYS
199 OPEN STYLE POWER RELAYS SPDT, DPDT, DPST-N.O., SPST-N.C.-D.B. & SPST-N.O.-D.M., 10 TO 50 AMPS LISTED 367G UL Listed File No. E43641 199 SPDT 30 AMP, 1-1/2 Hp 199 SPST--DB 30 AMPS, 2 Hp PLIES WITH REQUIREMENTS
More informationSpring Return DuraDrive Proportional Actuator
MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional
More informationMichigan State University Construction Standards WIRING DEVICES PAGE
PAGE 262726-1 SECTION 262726 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationMichigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE
PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationOpen Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationDPC F - P3-24. Part Number Scheme. Dimensions
Description Definite Purpose Contactor Definite Purpose contactors are electrically operated switching devices specifically designed for the heating, ventilation, air conditioning, heat pump and refrigeration
More informationRU Series Universal Relays
Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal
More informationMagnecraft Printed Circuit Board & Reed Relays. Catalog
Magnecraft Printed Circuit Board & Reed Relays Catalog 2010 Contents Series Overview....................................................3 117SIP Relays.....................................................4
More informationW7100A-E Discharge Air Controller
W7100A-E W7100A-E Discharge Air Controller The microprocessor based W7100 Discharge Air Controller maintains an average discharge air (DA) temperature in variable air volume (VAV) cooling systems by modulating
More informationAuxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)
Bulletin C,, C Accessories Accessories Auxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (A rating) as standard. Additional auxiliary contacts,
More informationOpen Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationRelays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:
RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator
More informationSteps for Selecting the Proper Transformer
SECTION I Page 4 Steps for Selecting the Proper Transformer SINGLE PASE LOADS 1. Determine electrical load A. Voltage required by load. B. Amperes or KVA capacity required by load. C. Frequency in z (cycles
More informationCustomer witness testing guide
Customer wtness testng gude Ths gude s amed at explanng why we need to wtness test equpment whch s beng connected to our network, what we actually do when we complete ths testng, and what you can do to
More informationPower PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).
Power PCB Relay Subminiature 20 L x 9.90 W x 9.90 H mm (0.79 L x 0.39 W x 0.39 H in) Low power consumption (200 mw) Sealed construction permits automatic soldering and cleaning of the PC board High-capacity
More informationG2RL-1A G2RL-1 G2RL-2A G2RL-2
9 PCB Relay High Capacity, Low Profile Relay Low profile:.7 mm max. in height Cadmium-free contacts ensuring environment-friendly use 0 kv impulse surge withstand Clearance and creepage distance: 0 mm/0
More informationSECTION 1 SOCKET COMPATIBLE AND FLANGE MOUNTED RELAYS 1 TO 30 AMPERES
Your Contact for Industrial Relays SECTION 1 SOCKET COMPATIBLE AND FLANGE MOUNTED RELAYS 1 TO 30 AMPERES SOCKET COMPATIBLE & FLANGE MOUNT RELAYS RELAY SERIES CERTIFIED CLASS 1 DIVISION 2 FOR HAZARDOUS
More informationGENERAL PURPOSE RELAYS
CONTROL LOGIC GENERAL PURPOSE RELAYS GR c3controls offers a full line of General Purpose Relays ( plug-in relays), perfect for your control logic applications. Quick and economical to install, our relays
More informationMini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors
More informationSPST-NO SPDT DPST-NO DPDT
PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0
More informationINSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY
INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS
More informationwww. ElectricalPartManuals. com Basler Electric -.. BE1-810/U DIGITAL FREQUENCY RELAY ADDITIONAL INFORMATION INSTRUCTION MANUAL
...... The BE181 0/U Digital Frequency Relay senses an ac voltage: from a power system or generator to provide protection in the event that the frequency exceeds predetermined limits. Reliable solidstate
More informationKRPA, KRP, KA, KR series
Catalog 1084 Issued -0 KRPA, KRP, KA, KR series to 10 Amp General Purpose Relay File E944, E, E818 (KR Hermetic) File LR14 KRPA KRP KA Users should thoroughly review the technical data before selecting
More informationNEMA Contactor and Starter Specifications
Technical Data NEMA Contactor and Starter Specifications Bulletins 00, 0, 0, 0, 06, 06X, 07, 07X, 09,,, E/F/G, E/F/G Topic Page Specifications Electrical Ratings Mechanical Ratings, Construction, Environmental
More informationRT series Miniature Printed Circuit Board Relays, Sockets and Accessories
s 查询 RT40 供应商 捷多邦, 专业 PC 打样工厂,4 小时加急出货 RT series Miniature Printed Circuit oard Relays, Sockets and ccessories pplied Coil Voltage (% of rated nom.) RT series (DC Coil) 6 mp PC oard Miniature Relay Meets
More informationPower Supplies for every application
Power Supplies for every application SRP SERES SRP-25 25 Watt Multi Output SRP-40A 40 Watt Multi Output SRW-100 100 Watt Multi Output Universal (85-264Vac) nput Low Power (25-100 Watt) Up to 4 Outputs
More informationFDM Medium Voltage Controller
1-1 LMR PLUS Product Description For over 50 years, EATON Corporation has been the industry leader in Medium Voltage Motor Control. The FDM Medium Voltage Fire Pump Controller is based on the AMPGARD controller
More information3.0 CHARACTERISTICS. Type CKO Overcurrent Relay. switch, which allows the operation indicator target to drop.
41-101.3A Type CKO Overcurrent Relay switch, which allows the operation indicator target to drop. The front spring, in addition to holding the target, provides restraint for the armature and thus controls
More information3RA13, 3RA14 Contactor Assemblies
RA, RA Contactor Assemblies RA Contactor Assemblies for Wye-Delta Starting RA complete units,... kw Siemens AG 0 Overview These RA contactor assemblies for wye-delta starting are designed for standard
More informationLegacy Printed Circuit Board & Reed Relays. Catalog
Legacy Printed Circuit Board & Reed Relays Catalog 2017 Contents Series Overview....................................................3 117SIP Relays.....................................................4
More informationOUTDOOR TRACK (PATENT PENDING)
1.91" (4.9cm) Micro Track Head Finish Micro Track Head Finish Features & Benefits Offers the flexibility of track lighting in an Exterior environment Uses 12VAC low voltage wiring without the need for
More information3RH1 contactor relays, 4- and 8-pole
Siemens AG 2010 RH, TH Contactor Relays RH1 contactor relays, 4- and 8-pole Overview AC and DC operation IEC 60947, EN 60947. The RH1 contactor relays are suitable for use in any climate. They are finger-safe
More informationBDC30A SERIES BRUSHLESS SERVO AMPLIFIERS Models: BDC30A8, BDC40A20
BDC30A SERES BRUSHLESS SERVO AMPLFERS Models: BDC30A8, BDC40A20 FEATURES: Surface-mount technology Small size, low cost, ease of use Standard input signal isolation Four quadrant regenerative operation
More informationRT series Miniature Printed Circuit Board Relays, Sockets and Accessories
RT series Miniature Printed Circuit oard Relays, Sockets and ccessories pplied Coil Voltage (% of rated nom.) RT series (DC Coil) 6 mp PC oard Miniature Relay Meets VDE 0mm Spacing, KV Dielectric File
More information30 A rated contacts Flange mount Faston 250 connections. 30 A rated contacts PCB mount - bifurcated terminals. Copper side view
66 Series - Power relays 30 A Features 66.22 66.82 2 Pole Changeover (DPDT) 30 A Power relay 66.22 PCB connections & mount 66.82 Faston 250 connections - Flange mount Reinforced insulation between coil
More informationCatalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009
Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred
More informationPCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test
PCB Relay A Power Relay for a Variety of Purposes with Various Models Conforms to VDE0 (VDE approval: C0 insulation grade), UL08, CSA., SEV, SEMKO. Meets VDE0700 requirements for household products according
More information62 Series - Power relays 16 A. Features / /
6 Series - Power relays 6 A Features 6. / 6.3 6.-0300 / 6.3-0300 Printed circuit mount 6 A Power relay & 3 Pole changeover contacts or NO ( 3 mm contact gap) AC coils & DC coils Reinforced insulation between
More informationSeries R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting
FANs 216, 121 Technical Bulletin R48 Issue Date 0695 Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting Table of Contents Mounting... 1 Output Control... 2 Wiring...
More informationMicro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13
Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC
More informationVariable Transformers Product Design & Engineering Data
Variable Transformers Product Design & Engineering Data Product Design & Engineering Data Type 1010B Cutaway General Information STACO ENERGY PRODUCTS CO. is a leading manufacturer of variable transformers,
More informationSPST-NO SPDT DPST-NO DPDT
PCB Relay A Power Relay with Various Models High-sensitivity ( mw) and High-capacity ( A) Models available. Low profile:.7 mm max. in height Conforms to VDE (EN0-), UL and CSA.. Meets EN0- requirements
More informationContents. Volume 7 Motor Controls, Logic and Connectivity CA E April V7-T40-187
Control Relays and Timers Alternating Relays.9 D85 Series Alternating Relays Contents Description D85 Series Alternating Relays Product Selection....................... Accessories...........................
More informationLegacy Printed Circuit Board & Reed Relays. Catalog
Legacy Printed Circuit Board & Reed Relays Catalog 2017 Contents Series Overview....................................................3 117SIP Relays.....................................................4
More information3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket
8-12 - 16 A Features 41.31 41.52 41.61 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 A (3.5 mm pin pitch) 41.52-2 Pole 8 A (5 mm pin pitch) 41.61-1 Pole 16 A (5 mm pin pitch) PCB mount - direct
More informationand START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3.
6-4 Freedom Pump Panels Circuit reaker R Enclosure / -Phase Magnetic / Interchangeable eater OLR These ECN Irrigation Pump Controllers feature the Cutler-ammer Freedom Series starters. They have a AND/OFF/AUTO
More informationFEATURES OPTIONAL FEATURES
-00--0 B Series The Assured Automation B Series electric valve actuators offer a rugged design for quarter turn industrial applications. Designed for use on quarter turn (0 ) ball valves, butterfly valves,
More informationPERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY SEALED
INCH-POUND MIL-PRF-6106/19G 18 November 2011 SUPERSEDING MIL-PRF-6106/19F 10 November 2000 PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY
More informationSection 2 Outdoor Voltage Transformers
Section 2 Outdoor Voltage Transformers GE Meter 130 Main St., Somersworth, NH 03878 USA & Canada: (800) 626-2004 Fax: (518) 869-2828; GE Worldwide: (518) 869-5555 2-1 120 V to 600 V BIL 10 kv Outdoor Voltage
More informationMODEL 421 Over/Under Motor Load Monitor
MODEL 421 Over/Under Motor Load Monitor Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or, Single-phase or 3-phase Built-in Trip and Restart
More informationTable of Contents. CII Mid-Range Relays
Table of Contents TD2 Series Time Delay Relays, per MIL-PRF-83726/28, /29, /30, & /31..........5-2 5-5 Double-pole, Electrically Held, 5 mps and Less FC-205 Series.................................................5-6
More informationalternating relays catalog a of products com
alternating relays catalog a of products 800.238.7474 www.macromatic.com com sales@macromatic.com com ALTERNATING RELAYS Typical Installations Alternating Relays are used in special applications where
More informationINSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.
INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. MANUAL PART NUMBER 180-0036 ORIGINAL: 1-17-83 REVISION: B (8-26-86) NOT TO BE CHANGED WITHOUT MSHA
More informationm m m Secondary RMS Rating Series Output
POWER TRANSFORMERS PRINTED CIRCUIT TRANSFORMERS "SIDE-WINDER" Single & Dual Priary-Split Bobbin-PC Mount Transforers These are copact transforers with priary and secondaries wound side by side. The "Side-Winder"
More informationGeneral Specifications for Unit Substations
E Shall Unit Substation - Specifications Unit Substation Dimensions Height: 62." -6. " (1,595.12 mm -1,747.52 mm) Width: 5.76" -71.5" (1,29. 3 mm -1,16.1 mm) Depth: 36." (914.4 mm) Approximate Weight:
More informationSealed Interface Control: EC20300
ISO 9001:2000 WITH DESIGN Certificate #02.002.1 Sealed Interface Control: EC20300 FEATURES: Weather tight control package Pulse Width Modulated output Waterproof altitude pressure and vapor release vent
More information24 HOUR TIME CONTROLS
http://waterheatertimer.org/paragontimersandmanuals.html http://waterheatertimer.org/pdf/intermaticcrossreference.pdf HOUR TIME CONTROLS 00, 0 and 0 Series One and One Half Hour Minimum ON or OFF Time
More informationVE 12 H M S E K HV VD (a) ( * ) (b) (c) (d) (e) (f) (g) (h) (i)
POWER RELAY 1 POLE 5 A (MEDIUM LOAD CONTROL) VE SERIES Lead Free FEATURES UL, CSA, VDE recognized 1 form A (SPST-NO) or 1 form C (SPDT) contact Low cost, miniature relay with big performance in small package
More informationRatchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj
Ratchet Relay Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation Each contact in the double-pole contact mechanism performs alternate make-brake operation at each pulse input
More informationFan and Pump AC Inverter
Fan and Pump AC Inverter Key Features for Fan and Pump Applications PID and Auto Energy Saving Functions. Input Phase Loss and Output Phase Loss Protection. LCD Keypad can be used to copy parameter settings
More informationLA-5000 SERIES LINEAR VALVE ACTUATORS
LA-5000 SERIES LINEAR VALVE ACTUATORS GENERAL DESCRIPTION The LA-5000 Series are bi-directional, linear actuators internally geared to produce up to 6,500 lbs. (28,913 N) of thrust, and offer continuous
More informationDistributed by: www.jameco.com 1-8-831-4242 The content and copyrights of the attached material are the property of its owner. POWER RELAY 1 POLE 3,, 1 A FBR16 SERIES FEATURES Compact with high power (3
More information7000 Series Bronze Globe Valves Two-Way Normally Open
7000 Series Bronze Globe Valves Two-Way Normally Open / to in. Screwed NPT Two-Way Normally Open Spring Return Stem Up Open Globe Valves Two-Way Normally Open Assemblies Size in. / /4 Cv (K vs ) 0.4 (0.4).
More informationPOWER RELAYS CONTINUOUS DUTY, TYPE II, UNSEALED INTERMITTENT DUTY, TYPE III, UNSEALED
POWR RLYS INUOUS DUTY, TYP II, UNSLD INTRMITTNT DUTY, TYP III, UNSLD General Specifications Designed to MIL-R- - Type II Unsealed ontinuous Duty - Type III Unsealed Intermittent Duty - overed/gasketed
More informationFlag indicator. Units. V Resistive Resistive Resistive HP HP Pilot Duty ma ~ ~ ~ ~ V V VA W. (Resistive) ms Vrms Vrms Vrms. C C g-n g-n. grams 1.
SETION Power Relays/SPDT, mp Rating (D & ) UL US UL Listed When Used With Magnecraft Sockets. Push-To-Test utton Removable Lock-Down Door Flag indicator LED Status Lamp UL Recognized File No. E Finger
More informationPage 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty.
Page -2 Page - DIRECT-ON-LINE STARTERS Motor ratings up to 9A 0V in IEC AC duty General use up to 6A / motor rating up to 2A 600V per UL/CSA Versions with Start-Stop/Reset buttons or Reset button Versions
More informationSENSOTEC UNIVERSAL INLINE TRANSDUCER AMPLIFIER BIPOLAR VOLTAGE MODEL. $!}~ f?(' 7. ()ept 1200 CHESAPEAKE AVE" COLUMBUS OHIO (614)
UNVERSAL NLNE TRANSDUCER AMPLFER BPOLAR VOLTAGE MODEL SENSOTEC 1200 CHESAPEAKE AVE" COLUMBUS OHO 43212 (614) 486-7723 $!}~- 822-7f?(' 7 )Rf/ f//ce ()ept 008-0295-00 Universallnline Transducer Amplifier
More informationESC11 SCOOP PROOF SERIES PRODUCT CATALOG
ESC SCOOP PROOF SERES PRODUCT CATALOG HREL Connectors, nc. a global leader in the engineering and manufacturing of highly reliable connectors. Products that by design been proven to exceed the diverse
More informationHARTMAN Lightweight High Performance DC Contactors
K Series Connectors Product Facts n Light weight n Small package size n Small footprint n Easy to package in panel assemblies n Buss bar mount or chassis mount n Designed to meet the applicable portions
More information! CAUTION D TABLE 1
Volts Line to Line 120 208 120 TABLE 1 (I L V LL ) 3 (single phase watts) Range Taps 20-120 20-30- 40-60- 80-100- 120 100-600 100-150- 200-300- 400-500- 600 35-200 35-50- 70-100- 140-175- 200 175-1000
More informationVA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service
VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service Product Bulletin Code No. LIT-977319 Issued September 26, 2014 The VA-9070 Series Electric Rotary Actuators for Two-Position
More informationWiring Information. Blinds & Shades
Wiring Information Blinds & Shades Except Silhouette Pirouette Vignette 3351 Jack Northrop Avenue, Hawthorne, CA 90250-4426 Tel: 310-220-2600 / 800-533-3040 Fax: 310-559-9764 email: sales@smautomatic.com
More informationHG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS
20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,
More informationElectro-Mech Scoreboard Co. Product Guide
Electro-Mech Scoreboard Co. Product Guide 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7846 Fax: (478) 864-0212 www.electro-mech.com Table of Contents Introduction to the ScoreLink System...3
More informationB15A SERIES BRUSHLESS SERVO AMPLIFIERS Models: B12A6, B15A8
B15A SERES BRUSHLESS SERVO AMPLFERS Models: B12A6, B15A8 FEATURES: Surface-mount technology Small size, low cost, ease of use DP switch selectable: current, open loop, or tachometer velocity mode Four
More informationNEMA Size 1 Cat. No. CN55DN3AB
-80 Contactors and Contents Description Product Family Overview Page Product Description....... -78 Features................ -78 Standards and Certifications........... -78 Selection.............. -79
More informationDPDT MJN2CF-IN* MJN2C-IN 3PDT MJN3CF-IN* MJN3C-IN Latching Plug-in DPDT MJN2CK
General Purpose Relay MJN Relay with Plug-in Termination, available in SPDT, DPDT or 3PDT models Rugged power driver offers superior 3/16 through-air and 3/8 over-surface spacing Interlocked frame and
More informationElectricity Fundamentals Training System
Electricity Fundamentals Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 07/2018 Table of Contents General Description 2 Courseware 2 Topic Coverage 2 List of Available Training
More informationSmartZone-2 & SmartZone-4
SmartZone-2 & SmartZone-4 Quick-Start Guide UPDATED 2011-7-26 This guide is intended to give the installer a brief set of instructions about how to set up the XCI Zoning SmartZone System. For more detailed
More informationKILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc
Product Facts Designed to be the smallest, lightest weight, lowest cost sealed contactor in the industry with its current rating (500+A carry, 2000A interrupt at 320VDC) Built-in coil economizer only 1.7W
More informationDX450 Red-D-Arc PARTS LIST FOR RETURN TO MAIN INDEX
Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-582 RETURN TO MAIN INDEX PARTS LIST FOR DX450 Red-D-Arc P-582 Index of Sub
More informationSafety Relay Unit. OFF-delay time
Safety Relay Unit The Series Offers a Complete Line-up of Compact Units. Four kinds of -mm wide Units are available: A -pole model, a -pole model, and models with poles and OFF-delay poles, as well as
More informationLow Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned
Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Part 1 - General Scope and Product Description 1.0 This specification contains the minimum design
More informationMA-1400 MA Professional Power Amplifier: MA Operating Instructions MA-1200 CH 2 CH 1 CH 1 CH 2 I I I I I I I I I I I I I I I I I I I I
8 8 8 8 Professional Power Amplifier MA-1200 MA-1400 MA-1600 Operating nstructions -18-16 -14-12 -10-8 -6 BRDGE -18-16 -14-12 -10-8 -6-20 -4 PROTECT -20-4 -21-2 C L P -21-2 - CH 1-0 SGNAL - CH 2-0 POWER
More information- Wiring Brochure Universal Reset Module 423e
- Wiring Brochure Universal Reset Module 4e W 4e 0/08 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications Rough In Wiring Rough-in wiring
More informationG7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information
Latching Relay CSM DS_E Compact Mechanical Lock Latching Relays with Manual Buttons Compact design with a height of 7 mm, width of. mm, and depth of 8. mm. Plus, one Relay only weighs 7 g. Quick set and
More informationH7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors
H765A, H7635A, H766A, H7636A Series 000 Humidity/Temperature Sensors WALL-MOUNT MODELS APPLICATI The H765A, H766A, H7635A and H7636A Wall-Mount Humidity/Temperature Sensors are universal Relative Humidity
More informationAll drive and motor parameters are stored in nonvolatile. Features
Description Power Range The DigiFlex Performance (DP) Series digital servo drives are designed to drive brushed and brushless servomotors. These fully digital drives operate in torque, velocity, or position
More informationApproved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories
Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Mirror contacts Screw fixing and snap fitting (35 mm DIN rail) Rated current
More informationOver or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors
Selection Guide...8.2 Over or Under ECS... 8.4 TCS... 8.8 Over and Under Monitor ECSW... 8.6 Transducer TCSA... 8.10 DCSA... 8.12 Indicator LCS... 8.14 LPM... 8.14 DIN Rail Mounting CM-SFS CM-SRS.1 CM-SRS.2
More informationPower Supplies 3. SDN-C Compact DIN Rail Series
SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs
More informationINSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending
INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF KB Part No. 9474 Signal Isolator for KBVF Controls See Page 1 Pending See Safety Warning on Page 1 The information contained in this manual is intended
More information62.22 Copper side view
62 Power relays 16 62 Printed circuit mount 16 Power relay 2 & 3 Pole changeover contacts or NO ( 3 mm contact gap) C coils & DC coils Reinforced insulation between coil and contacts according to EN 60335-1,
More informationSubminiature Automotive Relays Type CV20 Monostable
Subminiature Automotive Relays Type CV20 Subminiature relay Switching capacity 20 A DC coils 6 to 24 VDC 1 change over contact/1 double make contact High resistance to vibration and shock Low power consumption
More informationSUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand
More informationUtilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms
controls IEC Technical data D.C. Power circuit switching Utilization category DC- DC- DC- L/R ms L/R ms L/R 7. ms + + + V A 6.0 6.0 6.0 8 V A 6.0 8.0.0 60 V A 6.0.0. V A 7.0. 0. 0 V A 0.8 0. V A 6.0 6.0
More informationDU3 Ultrasonic Vehicle Detector
DU3 Ultrasonic Vehicle Detector INSTALLATION/MAINTENANCE INSTRUCTIONS The DU3 is a vehicle detector unit with selfcontained electronics, designed for use with a drive-thru timer system. It should be installed
More information