3RA13, 3RA14 Contactor Assemblies

Size: px
Start display at page:

Download "3RA13, 3RA14 Contactor Assemblies"

Transcription

1 RA, RA Contactor Assemblies RA Contactor Assemblies for Wye-Delta Starting RA complete units,... kw Siemens AG 0 Overview These RA contactor assemblies for wye-delta starting are designed for standard applications. Note: Contactor assemblies for wye-delta starting in special applications such as very heavy starting ) or wye-delta starting of special motors must be customized. Help with designing such special applications is available from Technical Assistance. The RA contactor assemblies for wye-delta starting can be ordered as follows: Sizes S00 to S: Fully wired and tested, with electrical interlock, dead interval of s on reversing (size S00 with electrical and mechanical interlocks). Sizes S00 to S: As individual parts for customer assembly. A dead interval of 0 ms on reversing is already integrated in the time relay function. There is also a range of accessories (auxiliary switch blocks, surge suppressors, etc.) that must be ordered separately. For overload relays for motor protection see "Protection Equipment" "Overload Relays" "RB Solid-State Overload Relays". The RA contactor assemblies have screw terminals and are suitable for screw and snap-on mounting onto mm standard mounting rails. Fully wired and tested RA contactor assemblies have one unassigned NO contact which is mounted onto the front of the K delta contactor. A solid-state time-delay auxiliary switch block is snapped onto the front of the complete contactor assemblies, size S00. kw, while a timing relay is mounted onto the side of sizes S0 to S, kw to kw. Rated data at AC 0 Hz 00 V Rating kw current I e A Motor current A Size Line/delta contactor ) For effective support from Technical Assistance you must provide the following details: - Rated motor voltage - Rated motor current - Service factor, operating values - Motor starting current factor - Starting time - Ambient temperature Star contactor complete Accessories for customer assembly Timing relays A, for double infeed S00-S00-S00 RT RT RA -XB-... RT -G RT RA -XB-... RP -N.0... S0-S0-S0 RT RT RA -XC-... RP -N RT RA -XC S-S-S0 RT RT RA -XC-... RP -N.0 RA -C ) RT S-S-S RT RA -XC-... RA -B )... RT RA -XC S-S-S RT RT RA -XC-... RP -N.0 RA -C ) RT RT RA -XC S-S-S RT RT -- RP -N RT RT RT RT S-S-S RT RT -- RP -N RT RT S-S-S RT RT -- RP -N RT RT RT Footnotes for page /: ) contains mechanical interlock, connecting clips; wiring modules on the top (connection between line and delta contactor) and on the bottom (connection between delta and star contactor); star jumper. ) contains connecting clips; wiring modules on the top (connection between line and delta contactor) and on the bottom (connection between delta and star contactor); star jumper. ) contains wiring module on the bottom (connection between delta and star contactor) and star jumper. ) Wiring module on top from reversing contactor assembly (note conductor cross-sections). /0 Siemens LV 0

2 Siemens AG 0 RA, RA Contactor Assemblies RA Contactor Assemblies for Wye-Delta Starting RA complete units,... kw Components for customer assembly s with wiring modules and, if necessary, mechanical connectors are available for contactor assemblies for wye-delta starting. Contactors, overload relays, wye-delta timing relays, auxiliary switches for electrical interlock if required also feeder terminals, mechanical interlocks (exception: In the case of the assembly kit for size S00 contactor assemblies the mechanical interlock between the delta contactor and the star contactor is included in the kit) and base plates must be ordered separately. The wiring kits for sizes S00 and S0 contain the top and bottom main conducting path connections between the line and delta contactors (top) and between the delta and star contactors (bottom). In the case of sizes S to S only the bottom main conducting path connection between the delta and star contactors is included in the wiring module, owing to the larger conductor cross-section at the infeed. Motor protection Overload relays or thermistor motor protection tripping units can be used for overload protection. The overload relay can be either mounted onto the line contactor or separately fitted. It must be set to 0. times the rated motor current. Note: The selection of contactor types refers to fused configurations (see note on Technical Information on page /). B, for single infeed Overload relay, thermal (trip class CLASS ) Star jumper Base plates Setting range Overload relay, solid-state (CLASS trip class) Setting range A A RA -B ) RT -BA RU -HB0... RB0 -SB0... RU -JB0 RA -B ) RT -BA RU -AB0... RB0 -QB RU -BB RU -DB0 RV -A RT -BA RA -E... RU -DB RB0 -UB RU -FB0 RT -BA RA -F... RU -GB RU -HB0 -- RT -BA RA -E... RU -JB RB0 -EB RU -LB0 RA -D ) RT -BA RA -E RB0 -FC -- RT -BA RA -E RB0 -GC -- RT -BA RA -E RB0 -MC Siemens LV 0 /

3 RA, RA Contactor Assemblies RA Contactor Assemblies for Wye-Delta Starting RA complete units,... kw Siemens AG 0 Selection and ordering data Fully wired and tested contactor assemblies Size S00-S00-S00. kw RA.-XB-... Rated data AC- current I e at 0 Hz and 00 V 0 V 00 V 00 V 0 V ) Coil operating range at 0 Hz: x ; at 0 Hz: x. ) Price AC operation, 0/0 Hz.... AC C RA -XB-AB0 unit 0.0 AC C RA -XB-AF0 unit 0.0 AC 0 } RA -XB-AP0 unit AC B RA -XB-AB0 unit 0.0 AC B RA -XB-AF0 unit 0.0 AC 0 } RA -XB-AP0 unit DC B RA -XB-BB unit DC } RA -XB-BB unit.0 NSB0_00 Accessories Page Individual parts Page K ) K ) K ) Auxiliary switch block, front Surge suppressors Three-phase feeder terminals ) Use version with NO. ) Use version with NC. RH RT RA -K / /, / / Contactor,. kw Contactor,. kw Solid-state time-delay auxiliary switch block, front unassigned NO contact Mechanical interlock RT RT RT -G. RT RT RH -BA RA -B RT RT connecting clips Wiring modules on the top and bottom for connecting the main and control conducting paths / / / / / / Siemens LV 0

4 Siemens AG 0 Fully wired and tested contactor assemblies Size S0-S0-S0. kw RA, RA Contactor Assemblies RA Contactor Assemblies for Wye-Delta Starting RA complete units,... kw RA.-XC-... Rated data AC- current I e at 0 Hz and ) Coil operating range at 0 Hz: x ; at 0 Hz: x. 00 V 0 V 00 V 00 V 0 V ) Price AC operation, 0/0 Hz.. AC C RA -XC-AC unit.00 AC C RA -XC-AG unit.00 AC 0 } RA -XC-AL unit.00 / 0. /. AC C RA -XC-AC unit.00 AC C RA -XC-AG unit.00 AC 0 } RA -XC-AL unit.00.. DC } RA -XC-BB unit.0 / 0. / DC } RA -XC-BB unit.0. NSB0_00b Accessories Page Individual parts Page K K K Mechanical interlock, lateral Solid-state time-delay auxiliary switch block, front ) Mechanical interlock, front Auxiliary switch block, lateral Surge suppressor Three-phase feeder terminal ) Three-phase busbar ) Push-in lug ) for timing relay screw fixing RA -B RT -G... RA -A RH -EA.. RT RV -A RT -CC0 RP 0 / / / / / / / ) Contactor, kw Contactors, /. kw Timing relay, lateral unassigned NO contact Auxiliary switch block for local control - units - units RT RT RT RT RP -N.0 RH -CA RH -CA0 RH -CA RA -B RT RT Connecting clips Wiring modules on the top and bottom for connecting the main and control conducting paths / / ) / / / ) Generally possible. If a solid-state time-delay auxiliary switch block is mounted onto the front of K, a standard auxiliary switch block can only be mounted onto the side. ) and can only be mounted with contactors with screw terminal (coil). ) Not included in the scope of supply of the preassembled contactor assemblies; can be ordered as an accessory. ) See "Monitoring and Control Devices: RP, PV Timing Relays" "RP Timing Relays in Industrial Enclosure,. mm". Siemens LV 0 /

5 RA, RA Contactor Assemblies RA Contactor Assemblies for Wye-Delta Starting RA complete units,... kw Siemens AG 0 Fully wired and tested contactor assemblies Size S-S-S0 0 kw Rated data AC- current I e at 0 Hz and 00 V 0 V 00 V 00 V 0 V ) Price AC operation, 0/0 Hz 0 /. / 0 0 /. / 0 AC C RA -XC-AC unit.0 AC C RA -XC-AG unit.0 AC 0 } RA -XC-AL unit.0 DC } RA -XC-BB unit.00 RA -XC-... ) Coil operating range at 0 Hz: x ; at 0 Hz: x. NSB0_00c Accessories Page Individual parts Page K K K Mechanical interlock, lateral Depth compensation required K:. mm; K: 0 mm ) Solid-state time-delay auxiliary switch block, front ) Auxiliary switch block, lateral Surge suppressors Three-phase feeder terminals Three-phase busbars Push-in lug ) for timing relay screw fixing RA -B RT -G... RH -EA.. RT RT RV -A RV -A RP 0 / / / /, / / / ) Use the RA -B base plate for this configuration. ) Generally possible. If a solid-state time-delay auxiliary switch block is mounted onto the front of K, a standard auxiliary switch block can only be mounted onto the side. ) Not included in the scope of supply of the preassembled contactor assemblies; can be ordered as an accessory. ) See "Monitoring and Control Devices: RP, PV Timing Relays" "RP Timing Relays in Industrial Enclosure,. mm". ) Contactors, /0 kw RT RT RT / Timing relay, lateral unassigned NO contact Auxiliary switch block for local control - units - units Base plate RP -N.0 RH -CA RH -CA0 RH -CA RA -E RA -C ) / / / / The assembly kit contains the star jumper on the top and the wiring module on the bottom for connecting the main current paths. / Siemens LV 0

6 Siemens AG 0 Fully wired and tested contactor assemblies Size S-S-S kw RA, RA Contactor Assemblies RA Contactor Assemblies for Wye-Delta Starting RA complete units,... kw RA.-XC-... Rated data AC- current I e ) at 0 Hz and Price 00 V 0 V 00 V 00 V 0 V 0 DC B RA -XC-BB unit.00 DC B RA -XC-BB unit.00 ) Coil operating range at 0 Hz: x ; at 0 Hz: x. AC operation, 0/0 Hz 0 AC C RA -XC-AC unit.00 AC C RA -XC-AG unit.00 AC 0 } RA -XC-AL unit.00 AC C RA -XC-AC unit.00 AC C RA -XC-AG unit.00 AC 0 } RA -XC-AL unit.00 NSB0_00b Accessories Page Individual parts Page K K K Mechanical interlock, lateral Solid-state time-delay auxiliary switch block, front ) Mechanical interlock, front Auxiliary switch block, lateral Surge suppressor Three-phase feeder terminal Three-phase busbars Push-in lug ) for timing relay screw fixing RA -B RT -G... RA -A RH -EA.. RT RT RV -A RV -A RP 0 / / / / /, / / / ) Contactor, kw RT RT Contactor, kw RT RT Timing relay, lateral RP -N.0 unassigned NO contact RH -CA Auxiliary switch block for local control - units - units Base plate RH -CA0 RH -CA RA -F RA -B RT RT / / ) / / / / The assembly kit contains the star jumper on the top and the wiring module on the bottom for connecting the main current paths. ) Generally possible. If a solid-state time-delay auxiliary switch block is mounted onto the front of K, a standard auxiliary switch block can only be mounted onto the side. ) Not included in the scope of supply of the preassembled contactor assemblies; can be ordered as an accessory. ) See "Monitoring and Control Devices: RP, PV Timing Relays" "RP Timing Relays in Industrial Enclosure,. mm". Siemens LV 0 /

7 RA, RA Contactor Assemblies RA Contactor Assemblies for Wye-Delta Starting RA complete units,... kw Siemens AG 0 Fully wired and tested contactor assemblies Size S-S-S kw RA.-XC-... Rated data AC- current I e at 0 Hz and 00 V 0 V 00 V 00 V 0 V ) Coil operating range at 0 Hz: x ; at 0 Hz: x. ) Price AC operation, 0/0 Hz AC B RA -XC-AC unit.000 AC B RA -XC-AG unit.000 AC 0 } RA -XC-AL unit AC B RA -XC-AC unit.000 AC B RA -XC-AG unit.000 AC 0 } RA -XC-AL unit.000 DC B RA -XC-BB unit.00 0 DC B RA -XC-BB unit.00 0 NSB0_00d Accessories Page Individual parts Page K K K 0 Mechanical interlock, lateral Depth compensation required K: 0 mm; K:. mm ) Solid-state time-delay auxiliary switch block, front ) Auxiliary switch block, lateral Surge suppressor Push-in lug ) for timing relay screw fixing Single-phase feeder terminals RA -B RT -G... RH -EA.. RT RP 0 RA -L / / / / ) Use the RA -B base plate for this configuration. ) Generally possible. If a solid-state time-delay auxiliary switch block is mounted onto the front of K, a standard auxiliary switch block can only be mounted onto the side. ) / Contactor, kw Contactor, kw Timing relay, lateral unassigned NO contact Auxiliary switch block for local control - units - units Base plate RT RT RT RT RP -N.0 RH -CA RH -CA0 RH -CA RA -E RA -C RT RT / / ) / / / / The assembly kit contains the star jumper on the top and the wiring module on the bottom for connecting the main current paths. ) Not included in the scope of supply of the preassembled contactor assemblies; can be ordered as an accessory. ) See "Monitoring and Control Devices: RP, PV Timing Relays" "RP Timing Relays in Industrial Enclosure,. mm". / Siemens LV 0

8 Siemens AG 0 RA, RA Contactor Assemblies RA Contactor Assemblies for Wye-Delta Starting Components for customer assembly Selection and ordering data s RA -B NSB0_0 Version Size DT Price mechanical interlock; connecting clips star jumper, wiring modules on the top and bottom connecting clips star jumper, wiring modules on the top and bottom star jumper, wiring module on the bottom (Wiring module on the top is not included in the scope of supply. A double infeed between the line contactor and the delta contactor is recommended.) S00-S00-S00 } RA -B unit 0.00 S0-S0-S0 } RA -B unit 0.00 S-S-S0 } RA -C unit 0.00 S-S-S } RA -B unit 0.00 S-S-S } RA -C unit 0.0 S-S-S } RA -B unit 0. S-S-S A RA -B unit 0.0 S-S-S A RA -N unit 0.00 S-S-S A RA -B unit.00 S-S-S B RA -B unit.00 kg RA -N, RA -B, RA -B Single-phase feeder terminals Conductor cross-section: mm S A RA -L unit 0.0 Three-phase feeder terminal Feeder terminal block for the line contactor for large conductor cross-sections Conductor cross-section: mm S00 } RA -K unit 0.00 Conductor cross-section: mm S0 } RV -AB unit 0.0 Conductor cross-section: 0 mm S } RV -A unit 0. Three-phase busbars Bridging phase-by-phase of all input terminals of the line contactor (K) and S0 D RT -CC0 unit 0.00 the delta contactor (K) S } RV -A unit 0.0 Links for paralleling, -pole (star jumpers) RT -BA Base plates NSB0_0 Without connection terminal (the links for paralleling can be reduced by one pole) For customer assembly of contactor assemblies for wye-delta starting with a laterally mounted timing relay ) The RT -EA (S) or RT -EA (S, S) cover can be used for touch protection. S00 } RT -BA unit 0.0 S0 } RT -BA unit 0.0 S } RT -BA unit 0.00 S } RT -BA unit 0.00 S ) } RT -BA unit 0. S, S ) } RT -BA unit 0.00 Side-by-side mounting S, S, S0 B RA -E unit 0.0 mm distance between K and K S, S, S B RA -F unit 0.0 Side-by-side mounting S, S, S B RA -E unit 0.0 mm distance between K, K and K S, S, S B RA -E unit.00 S, S, S B RA -F unit.0 S, S, S B RA -E unit.0 For customer assembly of contactor assemblies for wye-delta starting with a front-mounted timing relay, mm distance between K, K and K S, S, S B RA -F unit.00 S, S, S B RA -E unit.00 S, S, S B RA -F unit.00 S, S, S0 B RA -B unit 0.0 S, S, S B RA -B unit 0.0 S, S, S B RA -B unit 0.00 Siemens LV 0 /

Switching Devices Contactors and Contactor Assemblies for Switching Motors

Switching Devices Contactors and Contactor Assemblies for Switching Motors Switching Devices Contactors and Contactor Assemblies for Switching Motors groups 41B, 41H / Introduction Power contactors for switching motors /5 General data /11 SIRIUS RT10 contactors, -pole,... 50

More information

Industrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12. Catalog Add-On IC 10 AO 2012 SIRIUS. Answers for industry.

Industrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12. Catalog Add-On IC 10 AO 2012 SIRIUS. Answers for industry. Industrial Controls SIRIUS R_* in sizes S00/S0 to S Catalog Add-On IC 0 AO 0 SIRIUS Answers for industry. Controls Contactors and Contactor Assemblies for Switching Motors Price Groups PG B, H / Introduction

More information

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads) Overview Features Benefits 3RU11 3RB20/3RB21 3RB22/3RB23 Sizes Are coordinated with the dimensions, connections S00...S3 S00... S12 S00... S12 and technical characteristics of the other devices in the

More information

Controls Contactors and Contactor Assemblies Special Applications

Controls Contactors and Contactor Assemblies Special Applications Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for

More information

3RH1 contactor relays, 4- and 8-pole

3RH1 contactor relays, 4- and 8-pole Siemens AG 2010 RH, TH Contactor Relays RH1 contactor relays, 4- and 8-pole Overview AC and DC operation IEC 60947, EN 60947. The RH1 contactor relays are suitable for use in any climate. They are finger-safe

More information

SIRIUS/SIKOSTART Soft Starters For Standard Applications

SIRIUS/SIKOSTART Soft Starters For Standard Applications Overview SIRIUS RW0/1 Various versions of the RW0/1 SIRUS soft starters are available: Standard version for fixed frequency three-phase motors, sizes S00, S0, S2 and S Version for fixed-speed three-phase

More information

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Industrial Controls. Catalog IC SIRIUS. Answers for industry. Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor

More information

Solid-State Soft Starters

Solid-State Soft Starters Selection and ordering data Rated operational voltage U e V Soft starters for three-phase asynchronous motors 3RW30 25-1B14 3RW30 35-1B14 t ambient temperature 40 C Size Order No. Price Weight Pack. Rated

More information

Output of three-phase motors at 50 Hz and 400 V

Output of three-phase motors at 50 Hz and 400 V RT0, RH Coupling Relays (Interfaces) Description DC operation IEC 0 947 and EN 0 947 (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements

More information

Solid-State Switching Devices

Solid-State Switching Devices SIRIUS Solid-State Switching Devices Contents Pages Introduction.................................. 8/2 Solid-state switching devices General data.................................. 8/3 Solid-state switching

More information

3TX7, 3RS18 Coupling Relays

3TX7, 3RS18 Coupling Relays TX7, RS18 Coupling Relays TX7 Coupling Relays, Narrow Design Relay couplers Siemens AG 2010 Application AC and DC operation EN 60947, EN 60664-1 and EN 50005. In the coupling links in double-decker design,

More information

hp

hp General data Overview Function available, -- Function not available 1) Only soft starting available for 3RW30. 2) Optional up to size S3 (device version). 3) For 3RW402. to 3RW404.; for 3RW405. and 3RW407.

More information

General data 4/5. Overview. You can find further information on the Internet at:

General data 4/5. Overview. You can find further information on the Internet at: General data Overview SIRIUS SIRIUS 3RW0 SIRIUS 3RW Standard applications Standard applications High-Feature applications Rated at 0 C A 3... 106 12.5... 32 29... 121 Rated operational voltage V 200...

More information

SIRIUS 3RW Soft Starters 4/5 General data 3RW30, 3RW40 for Standard Applications 4/8 3RW30 4/18 3RW40 3RW44 for High-Feature Applications 4/34 3RW44

SIRIUS 3RW Soft Starters 4/5 General data 3RW30, 3RW40 for Standard Applications 4/8 3RW30 4/18 3RW40 3RW44 for High-Feature Applications 4/34 3RW44 Controls Soft Starters and Solid-State Switching Devices Price Groups 101, 131, 191 /2 Introduction SIRIUS 3RW Soft Starters /5 General data 3RW30, 3RW0 for Standard Applications /8 3RW30 /18 3RW0 3RW

More information

Price groups PG 41B, 41C, 41E, 41F, 41H, 41J, 42G, 42H, 42J, 401

Price groups PG 41B, 41C, 41E, 41F, 41H, 41J, 42G, 42H, 42J, 401 Controls Soft Starters and Solid-State Switching Devices Price groups 41B, 41C, 41E, 41F, 41H, 41J, 42G, 42H, 42J, 401 /2 Introduction SIRIUS 3RW soft starters /5 General data 3RW30, 3RW40 for standard

More information

Controls Solid-State Switching Devices

Controls Solid-State Switching Devices Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Relays /5 General data /6 3RF21 solid-state relays, 22.5 mm /12 3RF20 solid-state relays,

More information

3 - Protection components Circuit-breakers

3 - Protection components Circuit-breakers Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Switches Unlimited Contact: Phone: Fax:

Switches Unlimited Contact: Phone: Fax: Phone: 8--87 Fax: 78-67-67 - C Coil Three Pole - Series C7 C7 Non-Reversing, Three Pole With C Coil, Series C7 (Open type only) [] Ratings for Switching C Motors (C / C / C) kw (5 Hz) UL/CS HP (6 Hz) uxiliary

More information

For non-electrical quantities

For non-electrical quantities Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data

More information

Mini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU

Mini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU /0 Mini contactors B and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU Contents Mini Contactors B, BC, B 7, BC 7 Ordering Details... /2 Compact Reversing

More information

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4 /0 Block Contactors Contents Panorama -pole Contactors... / 4-pole Contactors... /4 -pole Contactors: Description and Ordering Details A 9... A 0 Contactors (a.c. Operated)... /6 A 4... AF 60 Contactors

More information

AC Coil $ Unit MRP R. DC Coil Voltage. Code n B4 F4 M4. Coil voltage Unit MRP DC Coil Voltage. Auxillary contacts A NO NC

AC Coil $ Unit MRP R. DC Coil Voltage. Code n B4 F4 M4. Coil voltage Unit MRP DC Coil Voltage. Auxillary contacts A NO NC SIIUS Innovations - Controls made easy elays - 3H () (uxiliary contactors) Operational Current Ie C-5 at 230V 0 Contacts Contacts NO NC $@ Please enter coil codes from table below * C Coil $ Unit MP *

More information

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13 Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC

More information

3TK28 Safety Relays. General data. 7/70 Siemens LV

3TK28 Safety Relays. General data. 7/70 Siemens LV 3TK28 Safety Relays General data Overview SIRIUS safety relays are the key elements of a consistent and cost-effective safety chain. Be it EMERGENCY-STOP disconnection, protective door monitoring or the

More information

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms controls IEC Technical data D.C. Power circuit switching Utilization category DC- DC- DC- L/R ms L/R ms L/R 7. ms + + + V A 6.0 6.0 6.0 8 V A 6.0 8.0.0 60 V A 6.0.0. V A 7.0. 0. 0 V A 0.8 0. V A 6.0 6.0

More information

Power Supplies. 11/2 Introduction. 4AV Non-Stabilized. Power Supplies

Power Supplies. 11/2 Introduction. 4AV Non-Stabilized. Power Supplies Siemens AG 009 Power Supplies / Introduction AV Non-Stabilized Power Supplies Filtered for Supply of Electronic Controls General data / - Overview / - Design / - Function / - Technical specifications AV,

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

Accessories Field Installable

Accessories Field Installable ccessories Field Installable Top (Front) Mount uxiliary Contact Blocks ➊ Contact Block NO NC 0 2 Contact rrangement 51 61 52 62 For use with... Standard Contacts Bifurcated Contacts ➋ C7 all CS7-PV-02

More information

Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750

Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750 Characteristics Contact characteristics of mini-control relays and instantaneous contact blocks Number of contacts On CAp-K 4 On L-K 2 or 4 for C-K and CA3-K: 2 for CA4-K Rated operational voltage (Ue)

More information

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7 Presentation Thermal-magnetic motor circuit-breakers types GV, GV and GV7 GV-ME, GV-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the control

More information

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors

More information

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg. Bulletin -K, -K IEC Miniature Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin -K/-K IEC Miniature Contactors Compact size Same dimensions for AC and

More information

Item Number No. Poles NO/NC V DC 50/60 Hz. Aux Contactor NO/NC Resistive/ Inductive Amps Price. AF Series

Item Number No. Poles NO/NC V DC 50/60 Hz. Aux Contactor NO/NC Resistive/ Inductive Amps Price. AF Series ABB Contactors Fits 35mm DIN rail Touch Safe Design Compact Design Captive Terminal Screws Built in surge protection (AF series only) Magnetic coil (AE series only) Electronically controlled coil (AE series

More information

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs Function have all the same advantages as the 3RW30/31 soft starters. At the same they come with additional functions and a two-phase control method (Polarity Balancing) that is unique in the rating range

More information

Inverter MICROMASTER 410

Inverter MICROMASTER 410 Inverter MICROMASTER 40 /2 Description /4 Circuit diagrams /6 Technical data /7 Selection and ordering data /8 Options /0 Dimension drawings Siemens DA 5.2 2005/2006 / MICROMASTER 40 Description Inverter

More information

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Modular equipment. Presentation, standards. Standard contactors TeSys GC Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on

More information

Monitoring Relays. 3RS10, 3RS11 Temperature Monitoring Relays. Relays, analog adjustable 7/55

Monitoring Relays. 3RS10, 3RS11 Temperature Monitoring Relays. Relays, analog adjustable 7/55 Overview Application The 3RS10/3RS11 analog temperature monitoring relays can be used for measuring temperatures in solid, liquid and gas media. The temperature is sensed by the sensors in the medium,

More information

3/4/2015. Basic relay construction. Shading coil in AC relays. Timothy L. Skvarenina and William E. DeWitt Electrical Power and Controls, 2e

3/4/2015. Basic relay construction. Shading coil in AC relays. Timothy L. Skvarenina and William E. DeWitt Electrical Power and Controls, 2e FIGURE 12-1 Basic relay construction. FIGURE 12-2 Shading coil in AC relays. 1 FIGURE 12-3 Contactor coil and shaded pole stators. FIGURE 12-4 Magnetic motor starter. 2 FIGURE 12-5 Thermal overload devices.

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..

More information

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Price* : 107.62 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

Motor starters. TeSys E. Designed for the essential

Motor starters. TeSys E. Designed for the essential Motor starters TeSys E Designed for the essential Designed for the essential Contents TeSys E contactors, 6 A to 300 A TeSys E thermal overload relays 0.1 A to 333 A TeSys E control relays 4 NO/NC contacts

More information

Semiconductor contactors, Solid-state relays

Semiconductor contactors, Solid-state relays Semiconductor contactors, Solid-state relays Content Benefits and advantages, approvals... 224 R100.xx semiconductor contactors, single-phase Ordering details... 225 Technical data... 228 Dimensional drawings...

More information

S1 Minor (usually reversible) injury S2 Serious (normally irreversible) injury including death

S1 Minor (usually reversible) injury S2 Serious (normally irreversible) injury including death General data Application Classification of a machine in categories acc. to EN 954- The 98/3/EG machinery directive stipulates that every machine must comply with the applicable guidelines and standards.

More information

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Type: DILEM 10(220V50HZ,240V60HZ) Article No.: Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230

More information

Prüf-Nr./Q-Nr. Certificate No. Dienststelle: Department: Ort: Place: Anlagen: Enclosures: Tech. Daten: Specification: U" r"'/ Ui = 690V, U p = 6kV

Prüf-Nr./Q-Nr. Certificate No. Dienststelle: Department: Ort: Place: Anlagen: Enclosures: Tech. Daten: Specification: U r'/ Ui = 690V, U p = 6kV SIEMENS Prüf-Nr./Q-Nr. Certificate No. Dienststelle: Department: Ort: Place: Anlagen: Enclosures: 2995 c DF CP R&D VC 2 / Drutschmann Amberg ras: 2016-08-02 Date: Product Description 2995 c Typprtifuescheinigung

More information

Crane Control Class 7001

Crane Control Class 7001 Catalog 17 CONTENTS Description.....................................................Page.................................................. 0 ST DC Static Timer............................................

More information

Contactors & Relays. Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators. Pg

Contactors & Relays. Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators. Pg Contactors & Relays Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators Pg 223 230 231 232 232 Contactors & Relays Contactor - GMC Series 3 Pole (240V) AC 1 Rati

More information

8WD4 Signaling Columns

8WD4 Signaling Columns Siemens AG 200 General data Overview The 8WD4 signaling columns are flexible in design and versatile in use. 1 1 2 2 3 3 4 5 4 6 8 5 6 10 11 8 12 15 13 14 10 NSC0_002 11 12 NSC0_0026 1 Acoustic element

More information

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) 4 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact Footprint Superior

More information

XT IEC Power Control Miniature Controls

XT IEC Power Control Miniature Controls Product Family Overview May 07 Contents Description Page Selection................ Product Selection.......... Non-reversing Mini Contactors......... Reversing Mini Contactors............. Star-Delta (Wye-Delta)

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Mirror contacts Screw fixing and snap fitting (35 mm DIN rail) Rated current

More information

Type: DILEM 10 G(24VDC) Article No.:

Type: DILEM 10 G(24VDC) Article No.: Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220

More information

For Immediate Delivery call KMParts.com at (866)

For Immediate Delivery call KMParts.com at (866) Return To MAIN INDEX Magnetic Contactors, Overview / Contactors DIL...M Contactors AC Operated AC Operated, Reversing DC Operated AC/DC Operated, DC Hp ratings / /6 /8 / Starters DIL Universal Contactors

More information

Reduced Voltage Starters

Reduced Voltage Starters Reduced Voltage Starters ontrolled starting for low in-rush and smooth operation Sprecher + Schuh reduced voltage starters are designed for starting squirrel cage induction motors where the starting current

More information

Reduced Voltage Starters

Reduced Voltage Starters Reduced Voltage Starters ontrolled starting for low in-rush and smooth operation Sprecher + Schuh reduced voltage starters are designed for starting squirrel cage induction motors where the starting current

More information

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC

More information

Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty.

Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty. Page -2 Page - DIRECT-ON-LINE STARTERS Motor ratings up to 9A 0V in IEC AC duty General use up to 6A / motor rating up to 2A 600V per UL/CSA Versions with Start-Stop/Reset buttons or Reset button Versions

More information

NS..S contactor relays - with spring terminals AC operated

NS..S contactor relays - with spring terminals AC operated NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed

More information

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors. Compact Contactors The CWC compact contactors are offered as a complete solution for switching and controlling motors. Main Features Contactors with screw s for C-3 operation up to Contactors with spring

More information

Accessories for A/AF/AL & AE contactors

Accessories for A/AF/AL & AE contactors 11Across the line Accessories for A/AF/AL & AE AL5-11 A5-10 Auxiliary contact blocks Standard Positioning Maximum ontact of contact blocks Description 4 blocks: A9 6 1 N.O. A5-10 AE9 AE26 1 N.. A5-01 Front

More information

page 10/20 page 10/21 pages 10/21-10/22 page 10/22 page 10/23 none 1 or 2 1 push button extended head red 3 or 4 1 twist lock mushroom red

page 10/20 page 10/21 pages 10/21-10/22 page 10/22 page 10/23 none 1 or 2 1 push button extended head red 3 or 4 1 twist lock mushroom red Rated agnetic Starters Industrial ontrols Product atalog 019 Section contents / Full Voltage Non-Reversing NEA X Non-etallic / Full Voltage etallic /8 Non - ombination /9 ircuit Breaker ombination / Fusible

More information

Semiconductor contactors, Solid-state relays

Semiconductor contactors, Solid-state relays Semiconductor contactors, Solid-state relays Content Benefits and advantages... 338 Approvals and marks... 338 Semiconductor contactors... 339 Ordering details... 339 R100.xx, single-phase... 339 R300.xx,

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide Bulletin S-C/S-C Safety Contactors Bulletin 7S-CF Safety Control Relays Selection Guide Table of Contents Description Page Bulletin S-C/S-C Safety Contactors Product Selection.................................

More information

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition

More information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

General data. 13/4 Siemens IC

General data. 13/4 Siemens IC General data Overview The 3SB2 pushbuttons and indicator lights are provided for front plate mounting and rear connection with flat connectors. For use on printed circuit boards, contact blocks and lampholders

More information

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC) Bulletin C,, C Accessories Accessories Auxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (A rating) as standard. Additional auxiliary contacts,

More information

1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.

1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max. Bulletin Definite Purpose Contactors Approximate Dimensions Dimensions shown in inches. Dimensions are not intended to be used for manufacturing purposes. / FLA - and -Pole.. max......... Typ..... max.......

More information

Characteristics 5 TeSys k contactors and reversing contactors

Characteristics 5 TeSys k contactors and reversing contactors 90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to

More information

190S A N D 2 C A16 C TE

190S A N D 2 C A16 C TE Bulletin / Eco and Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations

More information

Ratings for Switching AC Motors AC-2, AC-3, AC / /

Ratings for Switching AC Motors AC-2, AC-3, AC / / Bulletin -C/-C Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Ie [A] Bulletin -C/-C Compact sizes from kw/ Hp ( A) AC and DC coil control Common accessories for all contactor

More information

Commanding and Signaling Devices

Commanding and Signaling Devices Commanding and Signaling Devices /2 Introduction 3SB2 Pushbuttons and Indicator Lights, 16 mm /4 General data /6 Complete units /8 Actuators and indicators /10 Contact blocks and lampholders Accessories

More information

Power Supplies 3. SDN-C Compact DIN Rail Series

Power Supplies 3. SDN-C Compact DIN Rail Series SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs

More information

Electronic Step Controller

Electronic Step Controller 4 915 Electronic Step Controller, Adjustable switch-on delay (typically used to prevent current surges on startup and after a power failure) Adjustable switch-on points Adjustable switching differential

More information

Curves TeSys Model U 0 Starter-controllers

Curves TeSys Model U 0 Starter-controllers Curves TeSys Model U 0 Tripping curves for control units LUCA, LUCB, LUCD Average operating times at 0 C according to multiples of the setting current, tolerance : ± 0 %. Time (s) 000 00 0 0, LUCD, poles

More information

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00

More information

Variable Transformers Product Design & Engineering Data

Variable Transformers Product Design & Engineering Data Variable Transformers Product Design & Engineering Data Product Design & Engineering Data Type 1010B Cutaway General Information STACO ENERGY PRODUCTS CO. is a leading manufacturer of variable transformers,

More information

Miniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays

Miniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays Miniature & Starters Series family of, Starters, and Overload & Industrial Relays Miniature, Starters, Overload Relays & Industrial Controls List Prices shown in this selection guide are for use in the

More information

SOLID STATE RELAY RATINGS

SOLID STATE RELAY RATINGS Solid State Relays SOLID STATE RELAY RATINGS PART NUMBER HPR48A25 HPR48A50 HPR48A75 3PSS60A75 HPR48D25 HPR48D50 HPR48D75 Rated operational current AC51 @ Ta=25 C 25 AMPS rms 50 AMPS rms 75 AMPS rms 75

More information

SIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV

SIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV Certificate Number 20081124 E29197A Page 1 of 8 Report Reference E29197, 1974 September 17 Issue Date 2008 November 24 Issued to: This is to certify that representative samples of SIEMENS ENERGY & AUTOMATION

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Detecting Devices. 8/2 Introduction

Detecting Devices. 8/2 Introduction Siemens AG 29 Detecting Devices /2 Introduction 3SE5, 3SE2, 3SE3 Position Switches /4 General data /11 3SE5, plastic and metal enclosures /2 3SE2, plastic enclosures /26 3SE2, metal enclosures /36 3SE3,

More information

Connect - Contact - Control. DC Contactors 600V / 750V / 1000V. F 215e

Connect - Contact - Control. DC Contactors 600V / 750V / 1000V. F 215e Connect - Contact - Control DC Contactors 600V / 750V / 1000V F 215e 2 Contents Application... 3 Technical Data... 3 Load Ratings... 3 Device Identification... 4 Coil Power Reduction... 5 Fire Rating...

More information

17/2 Introduction. Display, Operation 17/6 Introduction 17/7 Pushbuttons 17/10 Pushbutton accessories 17/11 Remote controls

17/2 Introduction. Display, Operation 17/6 Introduction 17/7 Pushbuttons 17/10 Pushbutton accessories 17/11 Remote controls Siemens AG 2009 GAMMA wave Radio System /2 Introduction Display, Operation /6 Introduction /7 Pushbuttons /10 Pushbutton accessories /11 Remote controls Output Devices /12 Introduction /13 Binary output

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards APPROVED IGS Iranian Gas Standards Contactors. Fax:(9821)-8131-5679 --. /012 34-52673892 :;395- 8? /@A7 B;CD /E FGH 34-52673892I2

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

Siemens AG Motion Control Drives. SINAMICS S120 and SIMOTICS. Edition October Catalog News D 21.4 N. siemens.

Siemens AG Motion Control Drives. SINAMICS S120 and SIMOTICS. Edition October Catalog News D 21.4 N. siemens. Motion Control Drives Catalog News D 21.4 N Edition October 201 SINAMICS S120 and SIMOTICS siemens.com/drives Related catalogs Motion Control System PM 21 SIMOTION Equipment for Production Machines Industrial

More information

ECM3 EARTH CONTINUITY RELAY

ECM3 EARTH CONTINUITY RELAY TECHNICAL DATASHEET ECM3 EARTH CONTINUITY RELAY Electrical Protection for Hard Rock Mines Application The ECM3 has been designed to provide earth continuity protection for cables containing pilot cores.

More information

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker T e c h n i c a l C a t a l o g u e MCCB Moulded Case Circuit Breaker contents general overview... 2 feature - company profile and certifications... 6 MCCB - NF series circuit breaker, double repulsion

More information

FINAL - EST Electrical Service Technician Answer Schedule

FINAL - EST Electrical Service Technician Answer Schedule FINAL - EST 2069 - Electrical Service Technician Answer Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the accepted answers to the examination questions.

More information

Small but rugged DRAFT

Small but rugged DRAFT Series C8 and CT8 Starters n ingenious miniature contactor and starter system Sprecher + Schuh s New C8 Series of miniature contactors and starters provide an extremely compact and reliable method of controlling

More information

190S A N D 2 C A16 C TE

190S A N D 2 C A16 C TE Bulletin / Eco and Compact Combination Starters Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for

More information

Electronic timers CT-S range Selection and ordering details

Electronic timers CT-S range Selection and ordering details CT-S range Selection and ordering details Characteristics CT-S range CT-MFS 1SVR 430 010 F 0200 3 multifunction and 21 multi-range Continuous supply voltage range (24-240VAC/DC) or multisupply voltage

More information

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication

More information

General Catalogue. Quality made in D946E182

General Catalogue. Quality made in D946E182 General Catalogue Quality made in D946E182 Index Page Contactors, Motor-Starter (D677E) 3 Micro Contactors 11 Mini Contactors 25 Contactor Relays 39 Contactors 45 Starters 91 D.O.L. Starters 111 Overload

More information

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink AC Solid State Contactor, 1- and 2 poles Zero switching for heating and motor applications Instant-on switching Rated operational current

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information