CONVERTS 24 VOLT DC INTO AC POWER AC POWER APPLIANCES FROM A 24 VOLT BATTERY 24 VOLT DC TO AC
|
|
- Jasmin Gibbs
- 5 years ago
- Views:
Transcription
1 CONVERTS 24 VOLT DC INTO AC POWER AC POWER APPLIANCES FROM A 24 VOLT BATTERY 24 VOLT DC TO AC
2 50~200W(Rear) 50~200W(Front) AC output socket Power switch 250~350W(Rear) DC TERMINAL (RED) 250~350W(Front) AC output socket DC TERMINAL (BLACK) Power switch
3 400W(Rear) DC TERMINAL (RED) 400W(Front) AC output socket DC TERMINAL (BLACK) Power switch 500~600W(Rear) DC TERMINAL (RED) 500~600W(Front) Socket Power switch DC TERMINAL (BLACK) 800W(Rear) 800W(Front) DC TERMINAL (RED) Socket DC TERMINAL (BLACK) Power switch 2
4 000~2000W(Rear) 000~2000W(Front) DC TERMINAL (RED) DC TERMINAL (BLACK) Power switch Socket 2000~5000W(Rear) 2000~5000W(Front) 3
5 Model: 50W ~2000W Model: 3000W~5000W 4
6 RED BLACK RED BLACK 2V BATTERY 2V BATTERY Model: 50W ~2000W 5
7 RED BLACK RED BLACK 2V BATTERY 2V BATTERY Model: 3000W~5000W 6
8 7
9 8
10 9
11 Model: 50W ~2000W Model: 3000W~5000W 0
12
13 2
14 6.DETERMINING SUITABLE LOAD / APPLIANCES The inverter is fitted with to 2 approved EUROPEAN sockets (depending on model) either or both sockets can be used. As long as the combined load (Watts required to run appliance) does not exceed the inverter' continuous rating. All appliances have a rating plate that shows the amount of power (Watts) used or the current (Amp) drawn under normal use. The following table shows the maximum combined AC Amp Watts or AC Amp which can be run by the inverter. P/No. AC combined max load (Watts) AC combined max load (Amps) PI W 0.65A PI PI PI PI W 200W 250W 300W 0.76A 0.87A.09A.3A Number of sockets P/No. AC combined max load (Watts) AC combined max load (Amps) PI W.52A PI PS W 500W.74A 2.2A PS W 2.7A Number of sockets P/No. AC combined max load (Watts) AC combined max load (Amps) Number of sockets PI PI PI PI W 000W 200W 3.5A 4.4A 5.3A W 6.5A 2 P/No. AC combined max load (Watts) AC combined max load (Amps) Number of sockets PI PI PI PI W 3000W 4000W 8.7A 3.A 7.4A W 2.8A 2 Note: For 4000W & 5000W do not exceed 3500W (6Amp) per socket outlet. 3
15 Some appliances that use an electric motor or transformer may draw 2 to 6 times their rating when first turned on. these are called inductive loads and are the most difficult tor the inverter to run. For these appliances it is often a matter of trial and error to see what size inverter they will run on. if in doubt always use a larger inverter. The following table is a guide to the appropriate AC Watt drawn by various appliances. The DC Amp column shows the approximate power drawn from the 24 Volt supply. APPLICATION CHART Appliance S mall Air Compressor*/Water Heater S mall Air Compressor*/Water Heater Larger Power Tools*/Electric Kettle Circular Power Saw/Electric Chainsaw Toaster/Sandwich Maker Small Household Vacuum Cleaner Belt Sander & other Power Tools Small Microwave Oven (500/600W)* Combo TV/VCR Power Drill/Portable Grinder Flood Lights (500W) Submersible Pump* Small Colour Television* Small Power Tools/Fluorescent Light* Juicer/Blender Bar Fridge*/Large Stereo/PA Amplifier Hand Mixer Laptop Computer/Electric Knife Portable Stereo/CD/DVD/VCR/Playstation Charger/Mobile Phone/Camera/Camcorder 200W 500W 000W 3000W 5000W Approximate AC Watts DC Amps Appliance may require larger inverter. 7. HARD WIRED CONNECTION When mounting the inverter in a vehicle, boat or cabin it may be preferable to use longer DC battery cables than those supplied, so that the inverter can be placed in a more convenient cooler or more protected location. 4
16 PI PI PI PI PI Nominal Input Voltage (DC) 24V, 6.8A 24V, 8.0A 24V, 9.A 24V,.4A 24V, 3.7A Nominal Input Voltage Range (DC) 24V (20-30V) Output Power (Continuous Watts) 50W, 0.65A 75W, 0.76A 200W, 0.87A 250W,.09A 300W,.3A Output Power (Peak Watts)For 0.5 sec Standby Current 300W 0.3A 350W 0.3A 400W 0.2A 500W 0.2A 600W 0.2A Nominal Output Voltage (AC) Frequency 230V~ V~ 0V~ 50Hz 60Hz +/-5% Crystal Controlled Output Regulation Output Waveform Low Battery-Voltage Alarm (Volts) Low Battery-Voltage Shutdown (Volts) Efficiency Thermal Protection +/-5% Intelligent Pwm Modified Sine Wave 2+/-0.5V 20+/-0.5V 85~90% O O 65 C+/-5 C Overload Battery Polarity Reverse Output Short Shut Down & Alarm By Fuse Output Short Circuit Protection With Cooling Fan AC Outlets Socket Replaceable Fuse No 0A No 0A No 5A Yes 5A Yes 20A Dimension (L x W x H) cm 5x2.5x5.2 5x2.5x5.2 5x2.5x5.2 5x2.5x5.2 5x2.5x5.2 Weight 0.55Kg 0.7Kg 0.7Kg 0.7Kg 0.75Kg DC input voltage must be +24 VDC 5
17 Nominal Input Voltage (DC) Nominal Input Voltage Range (DC) Output Power (Continuous Watts) Output Power (Peak Watts)For 0.5 sec Standby Current PI PI PS PS PI V, 6A 24V, 8.3A 24V, 22.9A 24V, 27.5A 24V, 36.6A 700W 0.2A 800W 0.2A 24V (20-30V) 350W,.52A 400W,.74A 500W, 2.2A 600W, 2.7A 800W, 3.5A 000W 0.3A 200W 0.3A 600W 0.4A Nominal Output Voltage (AC) Frequency 230V~ V~ 0V~ 50Hz 60Hz +/-5% Crystal Controlled Output Regulation Output Waveform Low Battery-Voltage Alarm (Volts) Low Battery-Voltage Shutdown (Volts) Efficiency Thermal Protection +/-5% Intelligent Pwm Modified Sine Wave 2+/-0.5V 20+/-0.5V 85~90% O O 65 C+/-5 C Overload Battery Polarity Reverse Output Short With Cooling Fan Shut Down & Alarm By Fuse Output Short Circuit Protection Yes Auto-operation fan (temperature or load) AC Outlets Socket Replaceable Fuse 20A 2x5A 3x0A 3x5A 4x5A Dimension (L x W x H) cm 7x2.5x5.2 7x2.5x5.2 9x.x5.5 9x.x5.5 26x6.4x6.2 Weight 0.76Kg 0.87Kg.7Kg.75Kg 2.3Kg DC input voltage must be +24 VDC 6
18 PI PI PI PI Nominal Input Voltage (DC) Nominal Input Voltage Range (DC) Output Power (Continuous Watts) Output Power (Peak Watts)For 0.5 sec Standby Current Nominal Output Voltage (AC) Frequency 24V, 45.8A 24V, 55A 24V, 68.7A 24V, 9.6A 24V (20-30V) 000W, 4.4A 200W, 5.3A 500W, 6.5A 2000W, 8.7A 2000W 0.4A 2400W 0.4A 3000W 0.45A 4000W 0.6A 230V~ V~ 0V~ 50Hz 60Hz +/-5% Crystal Controlled Output Regulation Output Waveform Low Battery-Voltage Alarm (Volts) Low Battery-Voltage Shutdown (Volts) Efficiency Thermal Protection Overload Battery Polarity Reverse Output Short With Cooling Fan AC Outlets Socket Replaceable Fuse Dimension (L x W x H) cm Weight DC input voltage must be +24 VDC +/-5% Intelligent Pwm Modified Sine Wave 2+/-0.5V 20+/-0.5V 85~90% O O 65 C+/-5 C Shut Down & Alarm By Fuse Output Short Circuit Protection Yes Auto-operation fan (temperature or load) U.S.A Type: 2AC Outlets/European type: 2AC Outlets 6x0A 6x5A 9x0A 2x0A 26x9.8x7 26x9.8x7 32x9.8x7 43x9.8x7 2.9Kg 3.2Kg 4.3Kg 5.2Kg 7
19 PI PI PI Nominal Input Voltage (DC) Nominal Input Voltage Range (DC) Output Power (Continuous Watts) Output Power (Peak Watts)For 0.5 sec Standby Current Nominal Output Voltage (AC) Frequency 24V, 37A 24V, 83A 24V, 229A 24V (20-30V) 3000W, 3.A 4000W, 7.4A 5000W, 2.7A 6000W 0.6A 8000W 0.7A 0000W 0.8A 230V~ V~ 0V~ 50Hz 60Hz +/-5% Crystal Controlled Output Regulation Output Waveform Low Battery-Voltage Alarm (Volts) Low Battery-Voltage Shutdown (Volts) Efficiency Thermal Protection Overload Battery Polarity Reverse Output Short With Cooling Fan AC Outlets Socket Replaceable Fuse Dimension (L x W x H) cm Weight DC input voltage must be +24 VDC +/-5% Intelligent Pwm Modified Sine Wave 2+/-0.5V 20+/-0.5V 85~90% O O 65 C+/-5 C Shut Down & Alarm By Fuse Output Short Circuit Protection Yes Auto-operation fan (temperature or load) U.S.A Type: 4AC Outlets/European type: 2AC Outlets 8x0A 24x0A 30x0A 32x2x x2x5.5 46x2x Kg 8.0Kg 8.7Kg 8
20 CAUTION: ALWAYS PLACE THE INVERTER IN AN ENVIRONMENT WHICH IS: (A) WELL VENTILATED. (B) NOT EXPOSED TO DIRECT SUNLIGHT OR HEAT SOURCE. (C) OUT OF REACH FROM CHILDREN. (D) AWAY FROM WATER/MOISTURE, OIL OR GREASE. (E) AWAY FROM ANY FLAMMABLE SUBSTANCE (F) SECURE AND NO RISK OF FALLING.
THMS WATT WATT PEAK Other Models
DC-AC Power Inverter Modified Sine Wave 1000 Watts & Up Worktruck Power Inverters THMS Series THOR Manufacturing Modified Sine Wave inverters have set the standard with the way you deal with your mobile
More informationPure Sine Wave Inverter
1 Inverter Pure sine wave inverter is one of the most advanced DC to AC conversion products in the world, it has the main advantages of high quality sine wave AC output, microcomputer control, humanness
More informationSHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual
SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable
More informationOperation Manual. Congratulations on purchasing your high quality AIMS Power pure sine inverter!
Operation Manual Congratulations on purchasing your high quality AIMS Power pure sine inverter! It is very important that you read and understand this instruction manual completely prior to use. Contained
More informationGTI Series Inverters User Manual
GTI Series Inverters User Manual System Function directly connected to the solar panels (do not need to connect the battery) Using precise MPPT function, APL functions, the inverter automatically adjust
More informationMicrocare Pure Sine Wave Bi-Directional Inverters
MPPT Regulators, Pure Sine Wave Bi-Directional inverters, Grid Tied Inverters, and Grid Tied Limiters are designed, developed, and manufactured by MICROCARE in Port Elizabeth, South Africa Microcare Pure
More informationUser s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. SHI 400 / SHI 600 / SHI 1000 Pure Sine Wave Inverter The information presented in this document does not form
More informationSA-150, SA-300 Series Pure Sine Wave Inverter User s Manual
SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual List of contents 1. IMPORTANT safety Information... 1 1-1 General Safety Precautions.. 1 1-2 Battery Precautions 1 2. Features. 2 2-1 Electrical
More informationSEC. Technical Manual. SEC America, LLC. Model SFQ1K400 Frequency Converter
SEC SEC America, LLC Model SFQ1K400 Frequency Converter Technical Manual May 11, 2012 Table of Contents Page 1 Purpose of Manual 1 1 Purpose of Equipment 1 1.1 Description and Theory of Operation 1 2 Electrical
More informationAlternating Current Power
Chapter 4 Alternating Current Power MElec-Ch4-1 Overview What is Alternating Current AC Hazards AC Power Requirements Shoreside Utility System On-Board Generators MElec-Ch4-2 What is Alternating Current
More informationTS-700/1000 INVERTER Instruction Manual
TS-700/1000 INVERTER Instruction Manual TS-700/1000 Instruction Manual Index 1. Safety Guidelines... 1 2. Introduction... 1 2.1 Features... 1 2.2 Main Specification... 2 3. User Interface... 2 3.1 Front
More informationPURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05
PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05 Kert is always ready to help you! If you need: Advices
More informationMAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
More informationDPAfour125, DPAfour250 AMPLIFIERS. Operating Manual
DPAfour125, DPAfour250 AMPLIFIERS Operating Manual Operating manual, DPA Series DPA-10UMS01-V01R04 version revision date 01 02 24-02-2012 www.ateis-europe.com ATEÏS Europe BV - Sydneystraat 42-3047BP ROTTERDAM
More informationNOVA ELECTRIC A DIVISION OF
CGL SERIES PURE SINE-WAVE DC-AC INVERTERS CGL-SERIES INVERTER (Optional GCI Outlet shown) USER MANUAL TECHNOLOGY DYNAMICS INC. BERGENIELD, NJ 07621-2915 PHONE 201-385-0500 / AX 201-385-0702 EMAIL: novasales@theallpower.com
More informationTechnical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V
Technical Data Sheet Uninterruptible Power Supply On-line VH Series UPS 2000-3000 UL / 208V GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850
More information- 1 - GTI Grid Series. GTI Series Inverters For Grid User Manual
- 1 - GTI Series Inverters For Grid User Manual 1 - 2 - System Function Directly connected to the solar panels (do not need to connect the battery) Using precise MPPT function, APL functions, the inverter
More informationPlease use the Q & A utility to ask us any questions concerning the material being presented.
Meet Our Team Webinar Notes Please use the Q & A utility to ask us any questions concerning the material being presented. You can find a recording of this webinar and presentation on our Video Library
More informationPower Invertor. By Shridevi Bhat 17/09/2016
Power Invertor By Shridevi Bhat 17/09/2016 Introduction An electric current is a flow of electric charge. In electric circuits this charge is often carried by moving electrons in a wire. Direct Current
More informationSK Series Pure Sine Wave Inverter User s Manual
SK Series Pure Sine Wave Inverter User s Manual Contents 1. Important Safety Instructions 1 1-1 General Safety Precautions 1 1-2 Precautions When Working With Batteries.. 1 2. Features... 2 2-1 Application.
More informationMARUSON TECHNOLOGY CORPORATION E GALE AVE CITY OF INDUSTRY,CA U.S.MARUSONUSA.COM E MAIL:
USERS MANUAL PRODUCT: THREE PHASE QUICK-RESPONSE & HIGH PRECISION AVR MODEL: MEGA 33 AVR Series 9KVA/15KVA/25KVA 30KVA/45KVA/60KVA ISSUE DATE: 2015-12-02 VERSION: 1.0 MARUSON TECHNOLOGY CORPORATION 18557
More informationNational Physics. Electricity and Energy Homework. Section 2 Electrical Power
National Physics Electricity and Energy Homework Section 2 Electrical Power Homework 1 : Energy Changes and Power 1. Appliances convert electrical energy into other forms of energy. State the useful energy
More informationAC-DC BATTERY CHARGER 120~326W Portable Battery Charger 300~1000W Stationary Battery Charger
AC-DC BATTERY CHARGER 120~326W Portable Battery Charger 300~1000W Stationary Battery Charger DC-AC POWER INVERTER 500W Stand-alone Solar Inverter 100~2500W Modified Sine Wave 200~3000W True Sine Wave 1500~3000W
More informationProduct Catalog PRODUCT CATALOG. Power supply system & test equipment
Product Catalog PRODUCT CATALOG 2018 2018 Power supply system & test equipment. 138/79, Moo 2 Tambon Ban Klang, Amphoe Mueang Pathumthani, Pathumthani Province 12000, Thailand. Tel: +66 21475048-9 Fax:
More informationAC-DC BATTERY CHARGER 120~230W Portable Battery Charger 300~1000W Stationary Battery Charger
AC-DC BATTERY CHARGER 120~230W Portable Battery Charger 300~1000W Stationary Battery Charger DC-AC POWER INVERTER 500W Stand-alone Solar Inverter 100~2500W Modified Sine Wave 200~3000W True Sine Wave 1500~3000W
More informationLow Cost, Small Package, 120VAC Microstepping Drive
Catalog 8-4/USA E-AC Low Cost, Small Package, 12VAC Microstepping Drive Compumotor's new E-AC is a low-cost, high-performance, high-reliability microstepping drive in a small package. The design of the
More informationSWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)
SWF DV/DT Solutions Sinewave Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Does your application use variable frequency drives for improved
More informationSK Series Pure Sine Wave Inverter. User s Manual
SK Series Pure Sine Wave Inverter User s Manual Table of Contents 1. Important Safety Information. 1 1-1 General Safety Precautions 1 1-2 Battery Precautions.... 1 2. Features... 2 2-1 Application. 2 2-2
More informationCOM-POWER OPERATION MANUAL ACS W
COM-POWER OPERATION MANUAL For the ACS-250-100W 150 khz to 250 MHz 100W Power Amplifier Page 1 of 15 MANUAL_ACS-250-100W Rev. M02.15 Table of Contents Important Safety Precautions.....3 Introduction..5
More informationPURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES
PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES Kert is always ready to help you! If you need: Advices for the purchase
More informationPure sine wave inverter USER S MANUAL
USER S MANUAL INV10120700 / INV20120700 / INV30120700 INV10121000 / INV20121000 / INV10121500 INV20121500 / INV30121500 / INV10240700 INV20240700 / INV10241000 / INV10241500 INV20121500 Pure sine wave
More informationTel: Fax:
Grid Tie Solar Inverter Operator's Manual SG-4000 1 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS To reduce the risk of electrical shock and to ensure safe installation and operation of Grid Tie
More information! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.
Domestic Microwave Technical Information Over-The-Range Convection Microwave Models AMV404AAB/W/Q MMV405AAB/W/Q/S Due to possibility of personal injury or property damage, always contact an authorized
More informationCommercial Microwave Technical Information. CAUTION All safety information must be followed as provided in Service Manual
Commercial Microwave Technical Information 0 V, 0 Hz Models RCS0MPA P00M RCS0A P00M RCS0PBDA P00M RCS0MPSA P00M RFSMPSA P00M RFSSWA P00M RCS0SWA P0M RCS0MPA P0M Due to possibility of personal injury or
More informationMTPA Broadband Power Amplifier
MTPA20218343432 Broadband Power Amplifier 1.Product Description MTPA20218343432 is an air-cooled, broadband, solid state amplifier. This rack mount amplifier is based on Gan technology. It provides high
More informationThis article is designed to give you an insight into generators that can be used with your caravan or motorhome.
CONTENTS 1 SAFETY Take care! 2 INVERTERS Understanding how they work and the differences between them. 3 HOW AN ALTERNATOR WORKS All the bits you need to know 4 INVERTER PETROL GENERATORS Why are they
More informationMODEL 421 Over/Under Motor Load Monitor
MODEL 421 Over/Under Motor Load Monitor Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or, Single-phase or 3-phase Built-in Trip and Restart
More informationDD1-1300S. 500 Watts RMS Watts RMS Watts RMS- 1. Mono-Bloc Digital Power Amplifier
DD1-1300S Mono-Bloc Digital Power Amplifier 500 Watts RMS- 4 900 Watts RMS- 2 Ultimate Sound, Inc. 1300 Watts RMS- 1 Ultimate Europe AB Ultimate Sound, Inc Ultimate Europe AB 163 University Parkway Flojelbergsgatan
More informationSine Wave Power Inverter GD150/GD300 Series User s Manual
Sine Wave Power Inverter GD150/GD300 Series User s Manual Ver.1.04E Table of Contents 1. Safety Instructions... 3 2. General Information... 4 3. Inverter Features... 5 3-1 Specification...5 3-2 De-rating
More information6/24/02 DigiMod 500 DigiMod 1000 DigiMod 1500 DigiMod 2000HV DigiMod 1000NPS. User Manual
6/24/02 DigiMod 500 DigiMod 1000 DigiMod 1500 DigiMod 2000HV DigiMod 1000NPS User Manual COD: MAN-DGM-USER_MAN19-EN-11 NOV 2007 Caution CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN! IMPORTANT SAFETY INSTRUCTIONS!!
More informationsynchronized operation with utility AC source over voltage protection 0 ~ +40 C 20% ~ 90% RH non-condensing -30C ~ +70 C, 10 ~ 95% RH
True Sine Wave Output (THD < 3%) Power ON-OFF remote control Input and output fully isolated Advanced microprocessor Built-in transfer switch and AC circuit Remote override function or ignition lockout
More informationPower inverter 3000w pure sine wave
Power inverter 3000w pure sine wave 10 Best Power Inverters: The Most Reliable Inverters of 2018. AIMS power inverters are often better at the extremes than they are in the middle ranges of wattage capacity
More informationCURRENT, POTENTIAL DIFFERENCE AND RESISTANCE PART I
CURRENT, POTENTIAL DIFFERENCE AND RESISTANCE PART I Q1. An electrical circuit is shown in the figure below. (a) The current in the circuit is direct current. What is meant by direct current? Tick one box.
More informationBTM Series Pulsed RF Power Amplifier Modules. Application Note
BTM Series Pulsed RF Power Amplifier Modules Application Note Tomco BT Series Pulsed RF Amplifier Modules - Application note Contents Contents...2 Amplifier Safety Precautions...3 Hazardous Materials Warning:...4
More informationMODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR
MODEL 9050 EXTENDED SPECIFICATIONS Ü 50ppm TRANSPORTABLE CALIBRATOR 9050A EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last used up to 20 minutes maximum
More informationMES 2008 Errata Student Manual
MES 2008 Errata Student Manual 19 April 2009 Replace referenced paragraphs, figures, and homework questions with the following. Changes to text are underlined for clarity. Introduction Page vi 2-6 Soldering
More informationDIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS
CONTENTS CONTENTS CONTENTS 1. SAFETY INFORMATION...1 1.1 Preliminary...1 1.2 Dos and don ts...2 1.3 Symbols...3 1.4 Precautions...4 2. DESCRIPTION...5 2.1 Names of parts...6 2.2 Switches, buttons and input
More informationAF91 Adjustable Frequency Drives Series B
Effective: January, 00 Page New Information AF9 Adjustable Model AF9 Description Model AF9 Adjustable Frequency AC Drives are designed to provide adjustable speed control of -phase motors. These microprocessor-based
More informationPEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D
PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D T8211D 1 1. SAFETY INFORMATION BE EXTREMELY CAREFUL IN THE USE OF THIS METER. Improper use of this device can result in electric shock or destroy of
More informationCAUTION All safety information must be followed as provided in Service Manual
Domestic Microwave Technical Information AMV6167BD* JMV8166BA* JMV9169BA* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this
More informationTable of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17
Proximity Section 17 Table of Contents............ 21 2 Application Guide........................ 21 3 ACT Series Transducers......... 21 4 ACTR Series Transducers........ 21 6 ACS150 Series Switches..................
More informationDC-AC Power Inverter Pure Sine Wave PSR PSR Owner's Manual. Please read this manual BEFORE installing your inverter
DC-AC Power Inverter Pure Sine Wave PSR-1200-24 PSR-1200-48 Owner's Manual Please read this manual BEFORE installing your inverter OWNER'S MANUAL Index SECTION 1 Safety Instructions... 3 SECTION 2 General
More informationENCOUNTER AMPLIFIER MANUAL EN-1502 EN-3001 EN-3004
ENCOUNTER ENCOUNTER AMPLIFIER MANUAL EN-1502 EN-3001 EN-3004 ENGLISH AMPLIFIER SPECIFICATIONS EN-3004 (4 Channel) Class Class-AB Class-AB EN-1502 (2 Channel) Power 1800 Watts 1000 Watts Frequency Response
More informationEXPERIMENT 1 Safety, Instrumentation, and Measurement
ELEC 2010 Laboratory Manual Experiment 1 - Prelab Page 1 of 8 EXPERIMENT 1 Safety, Instrumentation, and Measurement Introduction The objectives of this experiment are to: Learn and apply principles of
More informationFreedom HF 1000 Freedom HF Owner s Guide. Freedom HF Inverter/Charger
TM TM Freedom HF 1000 Freedom HF 1800 Owner s Guide Freedom HF Inverter/Charger Trademarks Xantrex and Smart choice for power are trademarks of Schneider Electric Services International sprl, registered
More informationMIRAGE BD-35 DUAL BAND POWER AMPLIFIER
MIRAGE BD-35 DUAL BAND POWER AMPLIFIER INTRODUCTION: The Mirage BD-35 is a 45/35 watt dual band power amplifier for use with today's dual band handie talkies operating in the 144/440MHz bands. We have
More informationaudionet AMP 1 V2 User s Manual Stereo - Amplifier
audionet AMP 1 V2 Stereo - Amplifier User s Manual 1 2 Contents 1 Preface... 4 1.1 Included... 5 1.2 Transport... 5 2 Overview control elements... 6 2.1 Front panel... 6 3 Overview connections... 7 3.1
More informationModbus Register Map: InfraStruXure Symmetra 3-Phase Absolute Starting Register Number, (Decimal)
Modbus Map: InfraStruXure Symmetra 3-Phase 990-3249 // Status Word 0 40000 0 8 Reserved R = UPS ready to provide power to the load upon return of normal line voltage or upon user command = State == Enable
More informationGreen LED (right of 'D' type connector)
3050A EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last used up to 20 minutes maximum Standard Interfaces USB Optional Interfaces GPIB (IEEE-488) : RS232
More informationCAUTION All safety information must be followed as provided in Service Manual
Domestic Microwave Technical Information AMV564BC* MMV507BC* JMV808BC* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this
More informationDigiMod 3000PFC DigiMod 3000PFCsu
6/24/02 DigiMod 3000PFC DigiMod 3000PFCsu User Manual COD: MAN-DGM3K-USER_MAN_Ver-1.3 September 2008 Caution CAUTION RISK OF ELECTRIC SHOCK! DO NOT OPEN IMPORTANT SAFETY INSTRUCTIONS!! Read these instructions!!
More informationTechnical data Sheet HLD30-60 series
Technical data Sheet HLD30-60 Ref. HLD30-60 Hillstone - Dual Voltage DC / AC load banks HLD30-60 Portable Manual constant current control Lead Acid or Ni-cad battery testing Singe phase AC testing of UPS
More informationUSER MANUAL. Pure Sine Wave Inverter DC (12V) AC (230V) BP / BP / BP / BP POWER INVERTER
USER MANUAL Pure Sine Wave Inverter DC (12V) AC (230V) BP 600-12 / BP 1000-12 / BP 1500-12 / BP 2000-12 POWER INVERTER Thank you for purchasing our Power Inverter.It is a compact and highly portable power
More informationMINUTES OF PRE BID MEETING
MINUTES OF PRE BID MEETING Tender for Supply, Delivery, Installation & Commissioning of Equipment for Department of Engineering Technology, Faculty of Technological Studies Tender No : UWU/AHEAD/18/TS/ET/02
More informationUSER MANUAL VIVALDI MZ550A. Distribution Mixer Amplifier
USER MANUAL VIVALDI MZ550A Distribution Mixer Amplifier 1. Security Precautions Carefully READ the instruction in this manual before use. Be sure to OBSERVE the INSTRUCTION in this manual regard convention
More information8) Name three more types of circuits that we will not study in this class.
Name Concepts:( power ) 1) What is power? 2) What are the three equations for electrical power? 3) What are two units for power? 4) What does the power company sell its customers? 5) What is the unit sold
More informationSTEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. PDF created with FinePrint pdffactory trial version
STEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. INTRODUCTION Congratulations on your purchase of MA PR-150 Stereo Power Amplifier. The performance of PR-150 is perfect for any audio application,
More informationPower Supplies 3. SDN-C Compact DIN Rail Series
SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs
More informationSC1000 DGPS USCG Dual Transmitter
Southern Avionics Company's DGPS Reference Station Transmitter System. Model: SC1000 DUAL USCG SC1000 DGPS USCG Dual Transmitter QUALIFICATIONS: Meets applicable requirements of the United States Coast
More informationAC MASTER Switch mode sine wave inverter
USERS MANUAL / GEBRUIKERSHANDLEIDING / BETRIEBSANLEITING MANUEL D UTILISATION / MANUAL DE UTILIZACION / INSTRUZIONI PER L USO AC MASTER Switch mode sine wave inverter Models 12/200, 12/350, 24/200 & 24/350-230V
More informationTelonics Pro Audio. Telonics PA-4200/PA-200 Stereo Power Amplifier. Users Manual Telonics, Inc. All Rights Reserved PB Rev F
Telonics Pro Audio Telonics PA-4200/PA-200 Stereo Power Amplifier Users Manual 2010 Telonics, Inc. All Rights Reserved 2011.07.21 The Telonics PA-4200 Stereo Power Amplifier Congratulations on purchasing
More informationCAUTION All safety information must be followed as provided in Service Manual
Domestic Microwave Technical Information AMV564BA* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer to Service
More informationMODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division
MODULAR DC POWER SUPPLIES & SYSTEMS DC Power Systems DC/AC Inverters Static Switches DC/DC Converters GAMATRONIC, A SolarEdge Division 17 Hartom Street, Jerusalem 9777517, Israel 1-800-20-70-90 Tel: +972-2-5888277
More informationPure Sine Wave Inverter Driver Board Egs002 Eg8010 Ir2110
Pure Sine Wave Inverter Driver Board Egs002 Eg8010 Ir2110 PURE SINE WAVE INVERTER DRIVER BOARD EGS002 EG8010 IR2110 PDF - Are you looking for pure sine wave inverter driver board egs002 eg8010 ir2110 Books?
More informationUser Manual. Item #37 SA E T ESE INSTRUCTIONS
V1.1-M 17 2018 100 User Manual WARNING Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may
More informationChapter 13. Electric Circuits
Chapter 13 Electric Circuits Lower Potential Battery (EMF - E) - + Higher Potential Bulb (Resistor) Wires (No Change in Potential) EMF (Voltage Source) _ + Resistor Working Circuits For a circuit to work,
More informationREVAMP4120T Instruction manual
REVAMP4120T Instruction manual REVAMP4120T Instruction manual 3 REVAMP4120T manual 4 CLASS-D POWER AMPLIFIER IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions 2. Keep these instructions 3. Pay
More informationOperating Manual IMPORTANT NOTE: A Watt Mixer Amplifier. Redback Proudly Made In Australia
Operating Manual A 495 500 Watt Mixer Amplifier edback Proudly Made In Australia Distributed by Altronic Distributors Pty. td. Phone: 100 780 999 Fax: 100 790 999 Internet: IMPOTANT NOTE: Please read these
More informationSHORE TO SHIP FREQUENCY
POWER SYSTEMS INTERNATIONAL SHORE POWER POWER CONVERSION SYSTEMS 50Hz, 60Hz and 400Hz three phase and single phase There is a growing world focus on energy conservation with the drive towards reducing
More information79/26 Series III Multimeter
79/26 Series III Multimeter Instruction Sheet W Read First: Safety Information Never use the meter if the meter or test leads look damaged. Be sure the test leads and switch are in the correct position
More informationSPA2060, SPA2120, SPA2240 amplifier. User Manual
SPA2060, SPA2120, SPA2240 amplifier User Manual User manual, SPA-10UMS01-V01R03 Delivering Your Message version revision date 01 03 09-09-2011 www.ateis-europe.com ATEÏS Europe BV - Sydneystraat 42-3047BP
More informationOM1006 Solid State 50 MHz Power Amplifier
Instruction Manual OM1006 Solid State 50 MHz Power Amplifier OM POWER, s. r. o. 930 30 Báč 126 SLOVAKIA E-mail: om-power@om-power.com TABLE OF CONTENTS 1. GENERAL INFORMATION 1.1. Introduction.. 4 1.2.
More informationVCE VET Integrated Technologies
VCE VET Integrated Technologies Written examination End of year Examination specifications Overall conditions The examination will be sat at a time and date to be set annually by the Victorian Curriculum
More informationClass D Topology IR2110S S/N 87dB at 1 ohm All "N" Channel MOSFET TO218 Transistors Unregulated Power Supply 140 Volt Rails +/- for INSANE
3-4 5-9 10 11 12 Class D Topology IR2110S S/N 87dB at 15kW @ 1 ohm All "N" Channel MOSFET TO218 Transistors Unregulated Power Supply 140 Volt Rails /- for INSANE Amounts of Power Capacitance Voltage 160V
More informationDCM w Power Amplifier
DCM500 500w Power Amplifier HI MAINS TEMP ON 24 21 18 15 12 9 6 3 0 +3 FAIL DCM 500 Operating Manual DCM500, 500 Watt Power Amplifier Product Description The DCM500 is a 500 watt power amplifier designed
More informationAEE Solar Toroid Autotransformers. OutBack Power
AC Transformers Use an autotransformer as a step-down to connect the 240 VAC output of a generator to the 120 VAC input on an inverter. This allows full output power of a 240 VAC generator to be used for
More informationComm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems
Product Catalog 2014 Condensed Version INNOVATIVE CIRCUIT TECHNOLOGY LTD. ICT has been providing DC power conversion products since 1986 for two-way wireless communications, fixed wireless broadband and
More informationHIGH PERFORMANCE CAR AMPLIFIER
NS-1 HIGH PERFORMANCE CAR AMPLIFIER Digital Class-D Linkable Mono Block Amplifier Dual MOS-FET PWM Power Supply 1 Ohm Stable Load 24 db/octave - Variable Low Pass Filter 24 db/octave - Variable Subsonic
More informationAMM-1022 Digital Multimeter USER`S MANUAL
Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement
More informationUSER S MANUAL. 3KSS6050/ nd Edition
USER S MANUAL 3KSS6050/5060 2 nd Edition Frequency Converter Visicomm Industries LLC 4525 Sheridan Rd. Racine WI 53403 1. INTRODUCTION The conversion of electrical power is an essential requirement for
More informationThree phase sine wave inverter - 3KVA to 30KVA
Three phase sine wave inverter - 3KVA to 30KVA MEDI has designed and developed DSP based three phase / single phase sine wave inverter. This inverter can be used for the following applications 1. Offline
More informationGenerator Speed Controller Model GSC 1
enerator Speed Controller odel SC 1 RA 29 977/09.95 Replaces: 4.92 Self contained controller for driving electrical power generators with a hydrostatic transmission 16 Bit microprocessor based controller
More informationMajortel DC Power System
DC Power Solutions Majortel DC Power System Full power; Wide AC Range Complete System Design System Capacity Configurations Range from 1740W to 5800W Programmable Alarms Across 4 Sets of Dry-Contacts Battery
More information4X150A/7034 Radial Beam Power Tetrode
4X15A/734 Radial Beam Power Tetrode T The Svetlana 4X15A/734 is a compact radial beam tetrode. The 4X15A is intended for Class AB SSB linear RF amplifier service. It is intended for stationary and mobile
More informationDIGITAL MULTIMETER OPERATING INSTRUCTIONS MODEL CDM-35. Part No
DIGITAL MULTIMETER MODEL CDM-35 Part No.4500055 OPERATING INSTRUCTIONS 0304 The Meter may be hung on a wall, or supported as shown, depending upon which support is used. The probes may be located as shown,
More informationusing dc inputs. You will verify circuit operation with a multimeter.
Op Amp Fundamentals using dc inputs. You will verify circuit operation with a multimeter. FACET by Lab-Volt 77 Op Amp Fundamentals O circuit common. a. inverts the input voltage polarity. b. does not invert
More informationQuick Start RSDPB5000/RSDPB4000. High Voltage Differential Probe Series
Quick Start RSDPB5000/RSDPB4000 High Voltage Differential Probe Series 2 Please read this manual carefully before use Safety precautions 1. Be cautious of an electric shock 2. Pay attention to the maximum
More informationProfessional Stereo Amplifiers
Symbol 12000 Professional Stereo Amplifiers ENGLISH FBT elettronica S.p.A. - Via Paolo Soprani 1 - Zona Ind.le Squartabue - 62019 RECANATI (MC) - ITALY TEL. 071/750591 r.a. - FAX 071/7505920 - http://www.fbt.it
More informationElectrical And Electronics Engg
Electrical And Electronics Engg Rectifier Cubical panel type Voltage 3Ph 440V /(0-300V) DC 3Ph Isolation transformer-20kva Thyristor rating Current -300A/PIV - 1500V over load protection and necessary
More informationP-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control
P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control NEW FIRMWARE MAKES SETUP A SNAP Application based commissioning allows parameters
More information