Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

Size: px
Start display at page:

Download "Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17"

Transcription

1 Proximity Section 17 Table of Contents Application Guide ACT Series Transducers ACTR Series Transducers ACS150 Series Switches ACS200 Series Switches ACSX Series Switches Photoelectric Section 18 IEC Limit Switches Section 19 Section 20 Section 21 NEW Product! 21 1

2 Switches and Transducers The ACUAMP series is a family of high performance current sensors offering outstanding features, flexibility and durability at an incredible price. Choose from a wide selection of Transducer and Switch models, all designed in a rugged industry standard feedthrough package, consisting of both fixed core and split core models. Each model has multiple input ranges (set by movable jumpers) for maximum flexibility across many current ratings. The current transducer output choices include 4-20 ma, 24 VDC loop-powered and 0-10 volt selfpowered analog outputs. The Switch outputs are isolated solid state switches and are available in Normally Open configurations. A unit featuring field adjustable time delay is also offered in the Switch series. All models are panel-mountable as standard, and convenient DIN-rail adapter accessories are available. Use the selection guide to find the best sensor module for your requirements. ACUAMP Specifications by Model Type Specifications Transducer Transducer with True RMS Switch Switch Switch Model ACT ACTR ACS150 ACS200 ACSX Input Range Range Jumper selectable: ACT005: 0 to 2 A, 0 to 5 A ACT050: 0 to 10 A 0 to 20 A, 0 to 50 A ACT200: 0 to 100 A, 0 to 150 A, 0 to 200 A -10 models: 0-10 VDC -42L models: 4-20 ma, loop-powered Jumper selectable: ACTR005: 0 to 2 A, 0 to 5 A ACTR050: 0 to 10 A 0 to 20 A, 0 to 50 A ACTR200: 0 to 100 A, 0 to 150 A, 0 to 200 A 4-20 ma, loop-powered true RMS -F core: 1 to 150 A -S core: 1.75 to 150 A VAC or VDC Jumper Selectable: -F core: 1 to 6 A, 6 to 40 A, 40 to 175 A -S core: 1.75 to 6 A, 6 to 40 A, 40 to 200 A Jumper Selectable: -F core: 1 to 12 A, 12 to 55 A, 55 to 175 A -S core: 2 to 12 A, 12 to 55 A, 55 to 200 A -AA Model: 240 VAC -AA Model: 240 VAC -AD Model: 30 VDC -AE Model: 240 VAC/VDC Frequency Range -10 models: 50 to 60 Hz sinusoidal waveforms only -42L models: Hz 10 to 400 Hz non-sinusoidal waveforms 6 to 100 Hz 6 to 100 Hz 50 to 100 Hz Response Time Sensing Aperture -10 models: 100 ms -42 models: 300 ms -F core: 0.75 (19mm) dia. -S core: 0.85 (21.6mm) sq. 600 ms 120 ms 40 to 120 ms -F core: 0.75 (19mm) dia. -S core: 0.85 (21.6mm) sq. -F core: 0.75 (19mm) dia. -S core: 0.85 (21.6mm) sq. -F core: 0.75 (19mm) dia. -S core: 0.85 (21.6mm) sq.. Field adjustable time delay: 0.2 to 15 seconds -F core: 0.75 (19mm) dia. -S core: 0.85 (21.6mm) sq

3 Application Guide ACUAMP are a great fit for many applications, including material handling, fan and pump applications, and heating systems. With two basic models, Transducers and Switches and Transducers Application Guide Switches, this sensor family is a great fit for almost any current sensor need, ranging from monitoring loads to preventive maintenance. Models with the ability to read True RMS non-sinusoidal waveforms make it easy to monitor applications containing variable frequency drives. Use the application examples to help choose the best sensor model for your application. DL05/06 DL105 DL205 DL305 DL405 Field I/O Pump Jam & Suction Loss Protection Heater Life Prediction Software Control Signal Input ACS Series Operated Switch I Switch or Transducer C-more HMIs Other HMI AC Drives s Steppers/ Servos Controls Pump Load Monitoring Variable Frequency Drive 0-10v or 4-20mA Input to Controller True RMS Transducer Use: ACTR Series - True RMS Proximity Photo Limit Switches Pushbuttons/ Lights Process Crusher/Grinder/Shredder Interlocks The performance of size reduction equipment like crushers or grinders can be optimized by controlling the in-feed in order to Help prevent jamming improve the uniformity of the resultant product Enhance overall production efficiency s Inputs Lamp Failure Detection ACS Series Operated Switch L1 Relays/ Timers Comm. TB s & Wiring Power s Inactive Relay Contact L2 Circuit Protection Enclosures Switch or Transducer When L1 fails, the current drops. The Operated Switch detects the drop in current and activates the relay which turns on the back-up lamp L2. The system may be configured fail-safe by using a Normally Open switch together with Normally Closed relay contacts Appendix Part Index 21 3

4 ACT Series Transducers ACT current transducers combine a current transformer and signal conditioner into a single package. The ACT series has jumper-selected current input ranges and industry standard 4-20 ma or 0-10 VDC outputs. The ACT series is designed for application on linear or sinusoidal AC loads and is compatible with most s, data loggers and SCADA systems. Full-scale input ranges are userselectable from 2A to 200 A. This series is available in split-core or fixed-core models. Applications Automation Systems Analog current reading for remote monitoring and software alarms Data Loggers Self-powered transducer helps conserve data logger batteries Split-core enclosures make using portable data loggers easy Panel Meters Simple connection displays power consumption or other motor status Features Five-year Warranty 4-20 ma or 0-10 VDC outputs Use up to 14 AWG copper wires Factory matched and calibrated single piece transducer is more accurate than traditional two-piece field installed products Average responding algorithm gives an RMS output on pure sine waves. Perfect for constant speed (linear) loads or On/Off loads Jumper-selectable input ranges allow end-users to tailor sensing ranges and improves the odds of having the right range for the job is magnetically isolated from the input for safety and to eliminate voltage drop Agency Approvals UL, cul, CE approvals accepted worldwide ACT Series Transducers Part Number Description Pcs/Pkg Wt/lb ACT F AC current transducer, 0-10 VDC output, fixed core ACT S AC current transducer, 0-10 VDC output, split core ACT F AC current transducer, 0-10 VDC output, fixed core ACT S AC current transducer, 0-10 VDC output, split core ACT005-42L-F AC current transducer, 4-20mA output, fixed core ACT005-42L-S AC current transducer, 4-20mA output, split core ACT050-42L-F AC current transducer, 4-20mA output, fixed core ACT050-42L-S AC current transducer, 4-20mA output, split core ACT200-42L-F AC current transducer, 4-20mA output, fixed core ACT200-42L-S AC current transducer, 4-20mA output, split core Accessories DRA-2 DIN rail adapters, 1.69 x0.39 x0.75 (43x10x19 mm) ACT Series Specifications -10 Models -42L Models Power Supply Self-powered 24 VDC loop nominal, (40 VDC max) Loop-powered Signal 0-10 VDC 4-20 ma, Loop-powered Limit 15 VDC 32 ma Accuracy 1% full scale 1% full scale Response Time (10-90% step change) 100 ms 300 ms Input Ranges Field selectable from A Sensing Aperture -F core: 0.75 (19 mm) diameter; -S core: 0.85 (21.6 mm) sq. Isolation Voltage UL listed to 1,270VAC. Tested to 5,000 VAC (1 minute max) Frequency Range (for sinusoidal waveforms) 50 to 60 Hz 20 to 100 Hz Case UL 94V-0 flammability rated Environmental Temperature -4 to 122 F (-20 to 50 C) Humidity 0 to 95% RH, non-condensing Agency Listings UL listed 508, UL file E222847, CE approved Model ACT005 ACT050 ACT200 Maximum Input Ranges Maximum Input Amps Range Continuous 6 Sec max 1 Sec max 0 to 2A to 5A to 10A to 20A to 50A to 100A to 150A to 200A

5 Dimensions (in/mm) 3.03 " 77.0mm Ø 0.19 " 4.8mm 2.40 " 61.0mm ACT Series Transducers 0.93 " 23.6mm Ø 0.74 " 19mm 1.1 9" 30.2 m m 3.04" 77.3 m m 89.7 m m 2.40" 61m m Ø 0.19 " 4.8 m m DL05/06 DL105 DL205 DL305 DL405 Field I/O Software 2.18 " 3.50 " 88.9mm -F Style 0.85" 21.7 m m 0.86 " 21.7 m m 2.2 5" 57.2 m m -S Style C-more HMIs Other HMI AC Drives s 4 20mA Option 24 VDC Power ( ) (+) Load (+) (Controller, Meter, etc.) ( ) Steppers/ Servos Controls Proximity (VDC) Loop Power Range Jumper 0 10 VDC Option Range Jumper ( ) 2(+) 1( ) 2(+) Terminals are #6 screws. Notes: V L = 12VDC + (R L 0.020A) where V L = Minimum Loop Supply R L = Total Loop Resistance (Ohms) Captive screw terminals. Use AWG solid or stranded Observe polarity. >1M Recommended 100k Acceptable Power Supply (4 20mA output only) Operator Interface Panel Operating Range Total Loop Impedance (Ohms) Input to Controller Transducer, even on VFDs or SCRs Photo Limit Switches Pushbuttons/ Lights Process Relays/ Timers Comm. TB s & Wiring Power Circuit Protection Enclosures Appendix Part Index 21 5

6 ACTR Series Transducers The ACTR transducers combine a current transformer and a True RMS signal conditioner into one. These transducers are available in 4 to 20 ma output only. The ACTR Series provides True RMS output on distorted waveforms found on VFD or SCR outputs, and on linear loads in noisy power environments. Choose from fixed or split-core style. Applications VFD Controlled Loads VFD output indicates how the motor and attached load are operating SCR Controlled Loads Accurate measurement of phase angle fired or burst fired (time proportioned) SCRs. measurement gives faster response than temperature measurement Switching Power Supplies and Electronic Ballasts True RMS sensing is the most accurate way to measure power supply or ballast input power Features Five-year Warranty 4-20 ma output only True RMS technology is accurate on distorted waveforms like VFD or SCR outputs Choice of jumper-selectable ranges reduces inventory and eliminates zero and span pots. is magnetically isolated from the input for safety and eliminates voltage drop Agency Approvals UL, cul, CE approvals accepted worldwide Why use ACTR transducers? The current waveform of a typical linear load is a pure sine wave. In VFD and SCR applications, however, output waveforms are rough approximations of a sine wave, and are non-sinusoidal. There are numerous spikes and dips in each cycle. ACTR transducers use a mathematical algorithm called True RMS, which integrates the actual waveform over time. The output is the amperage component of the true power (heating value) of the AC current waveform. ACTR Series Transducers Part Number Description Pcs/Pkg Wt/lb ACTR005-42L-F AC current transducer with true RMS, 4-20mA output, fixed core ACTR005-42L-S AC current transducer with true RMS, 4-20mA output, split core ACTR050-42L-F AC current transducer with true RMS, 4-20mA output, fixed core ACTR050-42L-S AC current transducer with true RMS, 4-20mA output, split core ACTR200-42L-F AC current transducer with true RMS, 4-20mA output, fixed core ACTR200-42L-S AC current transducer with true RMS, 4-20mA output, split core Accessories DRA-2 DIN rail adapters, 1.69 x0.39 x0.75 (43x10x19 mm) True RMS is the only way to accurately measure distorted AC waveforms. Select ACTR transducers for nonlinear loads or in noisy power environments. Maximum Input Ranges Maximum Input Amps Model Range Continuous 6 Sec max 1 Sec max 0 to 2A ACTR005 0 to 5A to 10A ACTR050 0 to 20A to 50A to 100A ACTR200 0 to 150A to 200A Power Supply Signal Limit Accuracy Response Time (10-90% step change) Input Ranges Sensing Aperture Isolation Voltage Frequency Range Case Environmental Agency Listings ACTR Series Specifications -42L Models Temperature Humidity 24 VDC nominal, (12-40 VDC) Loop-powered 4-20 ma, loop-powered, true RMS 23 ma 1% full scale 600 ms Field selectable from A -F core: 0.75 (19 mm) dia. -S core: 0.85 (21.6 mm) sq. UL listed to 1,270VAC. Tested to 5,000 VAC (1 minute max) 10 to 400 Hz UL 94V-0 flammability rated 4 to 122 F ( 20 to 50 C) 0 to 95% RH, non-condensing UL listed 508, UL file E222847, CE approved

7 ACTR Series Transducers DL05/06 Dimensions (in/mm) 3.03" mm " 77.0mm Ø 0.19" Ø 4.8mm 0.19 " 2.40" 4.8mm 2.40 " 61.8mm 61.0mm Ø 0.74" 19mm 2.18 " " " 88.9mm 88.9mm 0.93" mm " 23.6mm Ø 0.74 " 19mm 2.18" Range Jumper -F Style -F Style 1.18" 30mm 1.18" 3.04" 77.2mm 89.7mm 2.40" 31mm 0.45" 11.4mm 0.85" 21.6mm 3.04" 2.40" 0.45" 0.85" 0.85" 21.6mm 0.86" 2.25" 57.2mm Ø 0.19" 4.83mm 2.25" Ø 0.19" Range Jumper -S Style -S Style DL105 DL205 DL305 DL405 Field I/O Software C-more HMIs Other HMI AC Drives s 4 20mA Option (VDC) Loop Power Range Jumper VDC Power ( ) (+) 1( ) 2(+) Power Supply (4 20 ma output only) 0 V L = 12VDC + (R L 0.020A) where V L = Minimum Loop Supply R L = Total Loop Resistance (Ohms) Total Loop Impedance (Ohms) Load (+) (Controller, Meter, etc.) ( ) Notes: Deadfront captive screw terminals ( F case) AWG solid or stranded Observe polarity Operating Range Operator Interface Panel 1000 Input to Controller Steppers/ Servos Controls Proximity Photo Limit Switches Pushbuttons/ Lights Process Relays/ Timers Comm. Variable Frequency Drive True RMS Transducer, even on VFDs or SCRs TB s & Wiring Power Circuit Protection Enclosures Appendix Part Index 21 7

8 ACS150 Series Switches ACS150 Series current operated switches combine a current transformer, signal conditioner and limit alarm into a single package for use in monitoring or proof of operation applications. Offering an adjustable setpoint range of 1 to 150 amps and universal, solid-state outputs, the self-powered ACS150 can be tailored to provide accurate and dependable digital indication of over-current conditions across a broad range of applications. The ACS150 is available in fixed-core and split-core models. Applications Electronic Proof of Flow operated switch eliminates the need for multiple pipe or duct penetrations More reliable than electromechanical pressure or flow switches Conveyors Detect jams and overloads; useful when interlocking multiple conveyor sections Heating Circuits Detect ON/OFF status; faster response times than with temperature sensors Loss of Load Detective Detect belt or coupling breaks with fast response times Lighting Circuits Easier and faster than photocells Features Five-year warranty N.O. Universal s VAC/VDC Status LED provides visual indication of setpoint trip and contact action Self-powered operation cuts installation time and operating costs Field-adjustable trip points speed start-up and allow for tailored operation Choose either split-core or fixed-core enclosure style. Split-core packages allow easy installation on existing systems ; fixed-core enclosures offer more compact package for OEM or new installations Integral mounting feet offer secure mounting Agency Approvals UL, cul, CE approvals accepted worldwide ACS150 Operated Switches Part Number Description Pcs/Pkg Wt/lb ACS150-AE-F N.O. AC/DC adjustable current switch in fixed core enclosure ACS150-AE-S N.O. AC/DC adjustable current switch in split core enclosure Accessories DRA-2 DIN rail adapters, 1.69 x0.39 x0.75 (43x10x19 mm) ACS150 Series Specifications Power Supply None - Self-powered Isolated solid-state switch Rating N.O VAC or VDC Response Time 120 ms Off State Leakage < 10 µa Fixed-core: 1 to 150 A. Input Ranges Split-core: 1.75 to 150 A Hysteresis 5% of Setpoint Overload (1 second duration) 1,000 A Isolation Voltage UL listed to 1,270VAC. Tested to 5,000 VAC (1 minute max) Frequency Range 6 to 100 Hz Case UL 94V-0 flammability rated Environmental Temperature -58 to 149 F (-50 to 65 C) Humidity 0 to 95% RH, non-condensing Agency Listings UL listed 508, UL file E222847, CE approved Type ACS150 Maximum Input Ranges Range - Maximum Input Amps Adjustable Continuous 6 Sec max 1 Sec max Fixed Core A Split Core A Minimum Load Operating ACS150 Minimum Load/MTBF MTBF (Mean Time Between Failure) x 10^6 ** 4.33 hours ** 4.33 hours ** The AC/DC switch output has no specified minimum load required to operate the output. There is a maximum resistance of 5 ohms across the output when the switch is on

9 ACS150 Series Switches DL05/06 Dimensions (in/mm) 3.03 " 77.0mm Ø 0.19" 4.8mm 2.40" Ø 0.19 " 61.8mm Ø 0.74" 4.8mm 2.40 " 19mm 61.0mm 2.18 " 3.03" 76.9mm 3.50" 88.9mm 3.50 " 88.9mm 0.93" 23.6mm 0.93 " Setpoint 23.6mm Adjust LED 2.18" FAN ON Controller Ø 0.74 " 19mm DO DI 1.19 " 30.2mm 1.19" 30.2mm NOT REQUIRED! 2nd Conduit, Wire, DP Switch, Pressure 2.25 Tubing, " Pipe Fitter, etc. 57.2mm Perfect Match for 3.53 " 89.7mm 2.40 " 61mm 0.85 " 21.6mm 2.25" 0.85 " 21.6mm 57.2mm Ø 0.19 " 4.8mm -F Style Out In -F Style Automation -S -S Style Style Systems LED 3.04 " 77.2mm 3.04" 77.3mm 89.7mm 2.40" 61mm 0.85" 21.7mm 0.86" 21.7mm Trip Point Adjust Ø 0.19" 4.8mm DL105 DL205 DL305 DL405 Field I/O Software C-more HMIs Other HMI AC Drives s Typical of Models with LED R Setpoint SmartLED 1 2 Terminals are #6 screws. Use up to 14 AWG copper wire L I N E AMPS Startup Inrush Underload or Status Normal Operation TIME Belt or Coupling Breaks AMPS Startup Inrush Overload or Jam Normal Operation TIME Jam MOTOR OFF Steppers/ Servos Controls Proximity Photo Limit Switches Control Signal Input Pushbuttons/ Lights Process ACS Series Operated Switch Relays/ Timers Comm. TB s & Wiring Power Circuit Protection Enclosures Appendix Part Index 21 9

10 ACS200 Series Switches ACS200 series current operated switches provide the same dependable status indication as the ACS150 series, but with added resolution. A choice of three jumper-selectable input ranges allows the ACS200 to be tailored to an application and provides more precision in setpoint adjustment. Self-powered, isolated solidstate relay outputs and multiple input ranges are standard features. Applications Electronic Proof of Flow operated switch eliminates the need for multiple pipe or duct penetrations, lowering installed costs Solid-state technology more reliable than electromechanical pressure or flow switches Conveyors Detect jams and overloads; useful when interlocking multiple conveyor sections Lighting, Heating Circuits Detect ON/OFF status, easier to install and less expensive than photocell or temperature sensor alternatives Features Five-year warranty N.O. Universal s 240 VAC or VDC Status LED provides visual indication of setpoint trip and contact action Self-powered operation cuts installation time and operating costs Field-adjustable trip points speed start-up and allow for tailored operation Choose fixed-core or split-core enclosure style. Split-core allows easy installation on existing systems; fixed-core offers more compact package for OEM or new installations Integral mounting feet provide secure mounting Agency Approvals UL, cul, CE approvals accepted worldwide ACS200 Operated Switches Part Number Description Pcs/Pkg Wt/lb ACS200-AA-F N.O. AC adjustable current switch, fixed core ACS200-AA-S N.O. AC adjustable current switch, split core ACS200-AD-F N.O. DC adjustable current switch, fixed core ACS200-AD-S N.O. DC adjustable current switch, split core Accessories DRA-2 DIN rail adapters, 1.69 x0.39 x0.75 (43x10x19 mm) ACS200 Series Specifications Power Supply None - Self-powered Isolated solid-state switch Rating N.O. AC: 240 VAC N.O. DC: 30 VDC Response Time ms Off State Leakage < 10 µa Jumper selectable: Fixed-core: 1 to 175 A. Input Ranges Split-core: 1.75 to 200 A Hysteresis low: 0.15A; mid: 0.3; high: 0.9A Overload (1 second duration) low: 600 A; mid: 800 A; high: 1,200 A Isolation Voltage UL listed to 1,270VAC. Tested to 5,000 VAC (1 minute max) Frequency Range 6 to 100 Hz Case UL 94V-0 flammability rated Environmental Temperature -58 to 149 F (-50 to 65 C) Humidity 0 to 95% RH, non-condensing Agency Listings UL listed 508, UL file E222847, CE approved Maximum Input Ranges Range Range - Jumper Fixed Core Range Maximum Input Amps Split Core 6 Sec max 1 Sec max NONE 1 to 6 A 1.75 to 6 A MID 6 to 40 A 6 to 40 A HIGH 40 to 175 A 40 to 200 A Switching Delay Delay LOW Range MID Range HIGH Range ON Delay 0.23 sec max 0.05 sec max 0.03 sec max OFF Delay 0.02 sec max 0.02 sec max 0.01 sec max Hysteresis 6% 4% 3% Part Number ACS200 Minimum Load/MTBF Min. Operating MTBF (Mean Time Between Failure) x 10^6 ACS200-AA-F 20 ma 4.29 hours ACS200-AA-S 20 ma 4.29 hours ACS200-AD-F 1 ma 4.39 hours ACS200-AD-S 1 ma 4.39 hours

11 ACS200 Series Switches DL05/06 Dimensions (in/mm) Ø 0.19 " 4.8mm 2.75 " 69.9mm 2.16 " 54.9mm 0.92 " 23.4mm 1.19 " 30.2mm 3.04 " 77.2mm 3.53 " 89.7mm Ø 0.19 " 4.8mm DL105 DL205 DL305 DL405 Field I/O Software 2.18 " Ø 0.55 " 14mm 2.40 " 61mm 0.85 " 21.6mm C-more HMIs Other HMI AC Drives Setpoint Input Range Jumper none low mid high 3.30 " 83.8mm Status LED Terminals are #6 screws Use up to 14 AWG copper wire L I N E AMPS FAN ON Controller 2.25 " Great 57.2mm with Relay Logic Control 0.85 " 21.6mm -F Style -S Style Startup Inrush DO Out DI In Underload or Status Normal Operation TIME Belt or Coupling Breaks AMPS Startup Inrush Input Overload or Jam Normal Operation TIME Jam MOTOR OFF s Steppers/ Servos Controls Proximity Photo Limit Switches Pushbuttons/ Lights Process ACS Series Operated Switch Relays/ Timers Comm. TB s & Wiring Power Circuit Protection Enclosures Appendix Part Index 21 11

12 ACSX Series Switches The ACSX series high-performance current-operated switch has a fieldadjustable time delay feature that minimizes nuisance trips during start-up and operation. These switches are designed for motor status applications where setpoint accuracy and repeatability are critical and offer a linear setpoint characteristic and constant hysteresis. Applications Protection Serves as an electronic proof-of-operation; detects current draw changes in motors when they encounter problems such as pumps running dry or impending bearing failure Non-intrusive; less expensive to install than differential pressure flow sensors or thermal switches Much quicker response time than Class 10 overload relays High Inrush or Temporary Overload Adjustable start-up/delay timer allows 0-15 second delay to eliminate nuisance trips from high inrush or short overload conditions ACSX Operated Switches Part Number Description Pcs/Pkg Wt/lb ACSX200-AA-F N.O. AC adjustable current switch, fixed core ACSX200-AA-S N.O. AC adjustable current switch, split core ACSX200-AE-F N.O. AC/DC adjustable current switch, fixed core ACSX200-AE-S N.O. AC/DC adjustable current switch, split core Accessories DRA-2 DIN rail adapters, 1.69 x0.39 x0.75 (43x10x19 mm) Features Standard features include self-powering, jumper-selectable ranges and a choice of outputs and core styles Five-year warranty Adjustable start-up/delay timer is fieldadjustable from 0.2 to 15 seconds to eliminate nuisance alarms caused by start-up inrush or temporary overcurrent conditions. Choice of N.O. AC or AC/DC outputs: Contact ratings of 240 VAC or universal outputs of 240 VAC/VDC for use with most standard motor control systems. Improved ease of installation and use: - 1.0A rating eliminates need for time delay relay - Self-powered, split-core models simplify installation - Status LED provides visual indication of setpoint trip and contact action Industrial grade performance - constant hysteresis and linear setpoint response for greater accuracy Agency Approvals UL, cul Listed CE approval pending ACSX Series Specifications Power Supply None - Self-powered Isolated solid-state switch Rating N.O. AC: 240 VAC N.O. AC/DC: VAC/VDC Response Time Adjustable 0.2 to 15 seconds Off State Leakage < 10 µa Jumper Selectable: Fixed core: 1 to 175 A Input Ranges Split core: 2 to 200 A Hysteresis 5% constant 2 to 12 A Range: 600 A; Overload (1 second duration) 12 to 55 A Range: 800 A; 50 to 200 A Range: 1200 A Isolation Voltage UL listed to 1,270VAC. Tested to 5,000 VAC (1 minute max) Frequency Range 50 to 100 Hz Case UL 94V-0 flammability rated Environmental Temperature 5 to 122 F (-15 to 50 C) operating temperature Humidity 0 to 95% RH, non-condensing Agency Listings UL listed 508, UL file E222847, CE approval pending Type Maximum Input Ranges Range - Maximum Input Amps Adjustable Continuous 6 Sec max 1 Sec max Fixed Core A Split Core A Part Number ACSX200 Minimum Load/MTBF Minimum Load Operating MTBF (Mean Time Between Failure) x 10^ hours 4.33 hours 4.29 hours 4.29 hours ACSX200-AE-F ** ACSX200-AE-S ** ACSX200-AA-F 20 ma ACSX200-AA-S 20 ma ** The AC/DC switch output has no specified minimum load required to operate the output. There is a maximum resistance of 5 ohms across the output when the switch is on

13 Dimensions (in/mm) 0.125" 3.2mm 0.75" 19mm dia " 24.56mm 1.506" 38.3mm S 2.433" 61.8mm 89.7mm LED 1.5" 39mm 3.08" 78mm Time Delay ACSX Series Switches high Range Use up to 14 AWG copper wire 2.18" mid 1.93" 49mm L I N E AMPS 0.931" FAN ON 23.7mm 0.17" 4.5mm int. dia. DO Typical of Controller 2 Out 0.6" 15mm Startup Inrush t DI In Normal Operation TIME 1.18" 0.125" 3.2mm 0.72" 18.3mm Belt or Coupling Breaks 0.857" 21.7mm LED Match for Automation Systems AMPS Trip Point Adjust 3.04" Startup Inrush t 2.4" 61mm 2.25" 57.2mm 0.52" 13mm NOT REQUIRED! 2.40" 2nd Conduit, Wire, DP 0.52" Switch, 0.854" Pressure Tubing, Pipe Fitter, etc. 13mm 21.7mm 0.45" Perfect89.7mm 2.4" 0.85" 61mm 0.86" Normal Operation TIME 0.36" Ø 0.19" 9.1mm 0.19" 4.5mm dia. Typical of 2 Jam 1.18" 30mm -F Style 3.044" -S Style 77.3mm -S Style Input Time Delay Adjust 2.25" Range Jumper MOTOR OFF DL05/06 DL105 DL205 DL305 DL405 Field I/O Software C-more HMIs Other HMI AC Drives s Steppers/ Servos Controls Proximity Photo Limit Switches Pushbuttons/ Lights Process ACSX Series Operated Switch Relays/ Timers Comm. TB s & Wiring Power Circuit Protection Enclosures Appendix Part Index 21 13

AC Current Transducers

AC Current Transducers Current Transducers are designed to provide an analog signal proportional to the AC current for monitoring, data logging and panel meter applications. NK Technologies current transducers offer a choice

More information

DC Current Transducers

DC Current Transducers Current Transducers are designed to provide an analog current reading for monitoring, data logging and panel meter applications. NK Technologies current transducers offer a choice of 5 VDC, 1 VDC or ma

More information

Automation Components, Inc. CURRENT 4-20 MA OUTPUT

Automation Components, Inc. CURRENT 4-20 MA OUTPUT D A T A S H E E T S Automation Components, Inc. CURRENT 4-20 MA OUTPUT 4-20 MA OUTPUT CTA2, SCTA2, CTA2-RMS & SCTA2-RMS Series The 4-20 ma Output Analog Current Sensors are designed for use in any AC current

More information

MODEL CTR - TRUE RMS AC CURRENT TRANSDUCER

MODEL CTR - TRUE RMS AC CURRENT TRANSDUCER Bulletin No. CTR- X Drawing No. LP0653 Effective 10/06 www.redlion.net MODEL CTR - TRUE RMS AC CURRENT TRANSDUCER TRUE RMS OUTPUT JUMPER SELECTABLE RANGES OUTPUT IS MAGNETICALLY ISOLATED FROM THE INPUT

More information

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors Selection Guide...8.2 Over or Under ECS... 8.4 TCS... 8.8 Over and Under Monitor ECSW... 8.6 Transducer TCSA... 8.10 DCSA... 8.12 Indicator LCS... 8.14 LPM... 8.14 DIN Rail Mounting CM-SFS CM-SRS.1 CM-SRS.2

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

current transformers or VAC secondary voltage from our SIGNAL CONVERTERS Selection Chart

current transformers or VAC secondary voltage from our SIGNAL CONVERTERS Selection Chart NK Technologies ADC series signal converters use sensor outputs (4 0 ma, 0 5 and 0 10 VDC) and convert these to digital RS485 outputs. The CTC series accept either 5 A secondary current from Analog to

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading

More information

DP2000 ORDERING GUIDE To Order MODEL NO.

DP2000 ORDERING GUIDE To Order MODEL NO. 1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition

More information

Industrial Current Sensors

Industrial Current Sensors Do you have other needs? Contact us for: Product Guide Application Guide Power Transducers, CTs and PTs Current Transducers and Transmitters Current Switches Current Fault Sensors For expert technical

More information

Temperature Transmitters - DIN Rail Mounted

Temperature Transmitters - DIN Rail Mounted XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

Temperature Transmitters - Head Mounted

Temperature Transmitters - Head Mounted XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A. P o w e r C O N T R O L S A N D a t h e n a c o n t r o l s. c o m ATHENA CONTROLS, INC. 5145 Campus Drive Plymouth Meeting, PA 19462-1129 U.S.A. TABLE OF CONTENTS Model Page Series 19/39 1 and Zero-Switched

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS

More information

Product Data Sheet. Models 1022/1025/1029C/1032/3629B 3629B. Models 1022/1025/1032. Model 1029C. Model 3629B. Phase Angle Power Control

Product Data Sheet. Models 1022/1025/1029C/1032/3629B 3629B. Models 1022/1025/1032. Model 1029C. Model 3629B. Phase Angle Power Control s 1022/1025/1029C/1032/3629B 3629B Product Data Sheet s 1022/1025/1032 Single phase power controllers Current ratings from 10 to 70 Amps 1022-0 to 5VDC or pot input 1025-4 to 20 ma signal 1032 Current

More information

Power Supplies 3. SDN-C Compact DIN Rail Series

Power Supplies 3. SDN-C Compact DIN Rail Series SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs

More information

MODEL 421 Over/Under Motor Load Monitor

MODEL 421 Over/Under Motor Load Monitor MODEL 421 Over/Under Motor Load Monitor Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or, Single-phase or 3-phase Built-in Trip and Restart

More information

NEW DIGITAL PUMP LOAD CONTROL

NEW DIGITAL PUMP LOAD CONTROL NEW DIGITAL PUMP LOAD CONTROL Power sensor monitors true motor power Waterproof & rugged, large red LED display Compact enclosure with flexible fittings Easy front panel keypad set up Low and high setpoint

More information

Electronic relays. Monitoring. Monitoring

Electronic relays. Monitoring. Monitoring Electronic relays Neither overload nor underload are particularly good for machines and installations in industrial applications. An unsteady power supply may lead to machine failure and, thus, expensive

More information

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 8, 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller

More information

Industrial Modbus I/O Modules

Industrial Modbus I/O Modules Industrial Modbus I/O Modules Modbus I/O Modules Introduction & Features Digital Input / Output Modules Analog Input / Output Modules Modbus I/O Modules The Best Choice For Your SCADA Applications Introduction

More information

Non-Submersible Industrial Pressure Transducer

Non-Submersible Industrial Pressure Transducer Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316

More information

Inverter Drive /Vector Drive Motors & Controls

Inverter Drive /Vector Drive Motors & Controls H2 Inverter/ Encoderless Vector Inverter Drive /Vector Drive & Controls 3/4 thru 50 180-264 VAC 3 Phase - 50/60 Hz 3/4 thru 60 340-528 VAC 3 Phase - 50/60 Hz 3/4 thru 60 515-660 VAC 3 Phase - 60 Hz HVAC

More information

Low Pass Harmonic Filters

Low Pass Harmonic Filters Exclusive e-rated Provider PRODUCT SHEET HARMITIGATOR TM Low Pass Harmonic Filters A solution for electrical distribution systems that require stable, reliable power, characterized by unparalleled power

More information

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C. ProLine Interface Technology Transducers for High Voltage / Shunt Applications Compact high voltage transducers with VariPower broad-range power supply and genuine calibrated range selection. The Task

More information

AF91 Adjustable Frequency Drives Series B

AF91 Adjustable Frequency Drives Series B Effective: January, 00 Page New Information AF9 Adjustable Model AF9 Description Model AF9 Adjustable Frequency AC Drives are designed to provide adjustable speed control of -phase motors. These microprocessor-based

More information

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

Spring Return DuraDrive Proportional Actuator

Spring Return DuraDrive Proportional Actuator MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional

More information

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays Dual-Source Power Supply Addendum to I.B. 17555 Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays Table of Contents Page 1.0 Introduction...1 2.0 General

More information

SC-FI Series Frequency to Current Signal Conditioner

SC-FI Series Frequency to Current Signal Conditioner SC-FI Series Frequency to Current Signal Conditioner 99829 08/27/01 INDEX DESCRIPTION... 1 SPECIFICATIONS... 1 TYPICAL WIRING HOOKUP... 1 INPUT & OUTPUT SETTINGS... 2 "L" OPTION SPECIFICATIONS... 3 "L"

More information

Advanced, accurate and intelligent monitoring for your transformer

Advanced, accurate and intelligent monitoring for your transformer QUALITROL 505 ITM Intelligent transformer monitor Advanced, accurate and intelligent monitoring for your transformer The power to know your transformer health immediately with TransLife Advanced thermal

More information

DRG-SC Series Signal Conditioners

DRG-SC Series Signal Conditioners DRG-SC Series Signal Conditioners DRG-SC Series 245 Basic unit Models Available for Thermocouples, RTDs, DC Voltage and Current, Frequency, Strain Gage Bridge, AC Voltage and Current Field Configurable

More information

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure New Product News Measuring & Monitoring Relays K8AK/K8DS Series DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays Compact 22.5 mm and 17.5 mm housings Resistant to high-frequency

More information

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC. DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC. MODEL SELECTION GUIDE The DIN Series of Digital Panel Meters are rugged low cost meters for the measurement of dc voltage, dc current, Process voltage

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

FEATURES OPTIONAL FEATURES

FEATURES OPTIONAL FEATURES -00--0 B Series The Assured Automation B Series electric valve actuators offer a rugged design for quarter turn industrial applications. Designed for use on quarter turn (0 ) ball valves, butterfly valves,

More information

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual IM-LZSA500-3 January 2008 Revision H Table of Contents LZS-A500-3 Power Supply 1) Safety and Recommended Practices 2 1.1 General

More information

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies. LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies. Its compact size, high efficiency, excellent reliability together with easy installation due to pluggable connectors makes

More information

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

ACH550 HVAC Drive Submittal

ACH550 HVAC Drive Submittal ACH550 HVAC Drive Submittal DATE: PROJECT NAME: CONTRACTOR: ENGINEER: SUBMITTED BY: SUBMITTALS FOR: RECORD APPROVAL (Return a copy of the approved submittal) ACH550 Features Standard Features UL and cul

More information

To be automatically connected to the nearest North American Technical Sales Office:

To be automatically connected to the nearest North American Technical Sales Office: DIN-A-MITE C SCR Power Controller Delivers Up To 80 Amperes in a Compact Package TOTAL CUSTOMER SATISFACTION 3 Year Warranty The Watlow DIN-A-MITE Style C silicon controlled rectifier (SCR) power controller

More information

HLC-1000 High-limit Humidity Control

HLC-1000 High-limit Humidity Control FANs 216, 1628.3 Product/Technical Bulletin HLC-1000 Issue Date 1197 HLC-1000 High-limit Humidity Control The HLC-1000 is designed to limit duct humidity by comparing a controller s request for humidification

More information

Level Control Methods and Explanations for Common Electrical Control terms. John A. Evans President, Motor Protection Electronics

Level Control Methods and Explanations for Common Electrical Control terms. John A. Evans President, Motor Protection Electronics Level Control Methods and Explanations for Common Electrical Control terms John A. Evans President, Motor Protection Electronics A Quick Florida Joke! Control Topic # 1 Level Sensing Options Level Sensing

More information

A cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications

A cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications A cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications The Micro 100 Drives have been designed with a Pulse Width Modulated (PWM) regulator to produce clean DC current to

More information

Milliamp Calibrator. Model 434. General description. Calibrate with laboratory accuracy. All 4 to 20 ma loop functions

Milliamp Calibrator. Model 434. General description. Calibrate with laboratory accuracy. All 4 to 20 ma loop functions Milliamp Calibrator Model 434 General description Calibrate Loop Instruments Calibrate and troubleshoot all the signals in a standard 4 to 20 milliamp process control loop with Altek s Model 434 Milliamp

More information

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A The CPCO Series (160mm aperture) Current Probes are Clamp On current sensors capable of measuring ac and dc currents. The Current Probe splits along a diameter allowing easy installation to existing cables

More information

02/11/2015

02/11/2015 Smart range with Removable Terminal blocks XD26RBT Smart Part number 88974561 Designed for industrial, commercial, medical and paramedical machines Faster maintenance process which improves the machine

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch

More information

TOSHIBA International Corp

TOSHIBA International Corp TOSHIBA International Corp GUIDE SPECIFICATIONS THREE PHASE UNINTERRUPTIBLE POWER SYSTEM TOSHIBA 4200FA 30 kva CT Internal Battery UPS GUIDE SPECIFICATIONS 1 (30 kva CT) 1.0 SCOPE 1.1 System This specification

More information

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com

More information

Installation and Operating Manual

Installation and Operating Manual GB Analog Weight Transmitter PS-1000 Installation and Operating Manual LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section

More information

The SSR P Series. Phase-Fired SCR Power Controllers. for resistive heating loads. Phase-Fired SCR Power Controllers AMPS VAC

The SSR P Series. Phase-Fired SCR Power Controllers. for resistive heating loads. Phase-Fired SCR Power Controllers AMPS VAC The SSR P Series Phase-Fired SCR Power Controllers 15-70 AMPS 80-600 VAC Phase-Fired SCR Power Controllers for resistive heating loads. ROBICON 1996 Rev. 12/96 Applications The SSR P series models are

More information

Zelio Control Measurement Relays

Zelio Control Measurement Relays Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and

More information

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test A new standard for Hipot & Insulation resistance testing Applied to World-Wide input voltage TOS5301 TOS5300 TOS5302 TOS5300(ACW) TOS5301(ACW/DCW) TOS5302(ACW/IR) New low-cost standard model that provides

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

DSA150 Series. xxx Series. 150 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125. 15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty

More information

General Purpose Drives

General Purpose Drives AC Variable Speed Drive General Purpose Drives Dedicated to Low Power Applications 0.37kW 11kW / 0.5HP 15HP 200 480V 3 Phase Input AC Variable Speed Drive 0.37kW 11kW / 0.5HP 15HP 110 480V Single & 3 Phase

More information

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification General The VT76x7 series is designed for single-stage and multi-stage control of heating/cooling equipment such as rooftop

More information

Improve asset protection and utilization

Improve asset protection and utilization QUALITROL 509 ITM Intelligent transformer monitor Improve asset protection and utilization Immediately know your transformer health with TransLife Optimize loading and equipment life Simplify root cause

More information

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000 High-Voltage Isolation Amplifiers / Shunt Isolators VariTrans P 29000 Compact high-voltage isolators with safe galvanic isolation, VariPower broad-range power supply and genuine calibrated range selection.

More information

CSI 9330 Vibration Transmitter

CSI 9330 Vibration Transmitter Machinery Health Management O-9330-110512 Product Data Sheet November 2012 CSI 9330 Vibration Transmitter n Continuously monitors critical machinery in process applications and other industrial environments

More information

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B PEAKTRONICS The Peaktronics AC Motor Controller is a compact module that is intended for controlling small AC actuator motors of up to 2A. The is very well suited for applications where space constraints

More information

9330 Vibration Transmitter

9330 Vibration Transmitter Reliability Solutions Product Data Sheet June 2017 9330 Vibration Transmitter Continuously monitors critical machinery in process applications and other industrial environments Interfaces with existing

More information

ES-777-MV-P2_A1 03/01/10

ES-777-MV-P2_A1 03/01/10 ENGINEERING SPECIFICATION SYMCOM MODEL 777-MV-P2 Electronic Overload Relay PART 1 GENERAL 1.1 REFERENCES A. UL 508 Industrial Control Equipment Underwriters Laboratories B. IEC 60947 Low Voltage Switchgear

More information

Phoenix DX Clean Power (18 Pulse) AC Drive

Phoenix DX Clean Power (18 Pulse) AC Drive PHOENIX DX Phoenix DX Clean Power (18 Pulse) AC Drive Poor power quality can be costly. Nonlinear loads, including AC Drives, introduce undesirable harmonic currents into the power system that can damage

More information

RN Thyristor Controllers

RN Thyristor Controllers Data Sheet RN Thyristor Controllers RN Thyristor Controllers Thyristor Controllers (solid state relays) provide a means of varying the voltage for electrically resistive s, typically electric heating elements.they

More information

Programmable Universal Frequency Transducer

Programmable Universal Frequency Transducer Programmable Universal Frequency Transducer Data Sheet 0A April 000 Features Completely programmable frequency range from 0. Hz 0 khz (programmed using membrane keypad) LCD to display the input or output

More information

ADJUSTABLE SPEED DRIVES FS1

ADJUSTABLE SPEED DRIVES FS1 ADJUSTABLE SPEED DRIVES FS1 Now Available With LonWorks BACnet & MetasysN2 FS1 Model FLA & Dimensions (in.)/ Weight (lbs.) VOLTAGE HP MODEL NUMBER FLA FRAME Dimensions (in.) SHIPPING H W D WEIGHT (lbs.)

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

Fluke Clamp Meters Solutions for every need

Fluke Clamp Meters Solutions for every need Fluke Clamp Meters Solutions for every need 381 355 773 more solutions inside Clamp Meter selection chart Job functions Applications Recommended clamp Process Technician/ Automation Specialist Multiple

More information

Electrical Motor Controls Chapter 5 (4 th Edition) Chapter 5 (5 th Edition)

Electrical Motor Controls Chapter 5 (4 th Edition) Chapter 5 (5 th Edition) Electrical Motor Controls Chapter 5 (4 th Edition) Chapter 5 (5 th Edition) 1. How many loads should be placed in any one circuit line between L 1 and L 2? 2. If more than one load is controlled by the

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS Zlinx Wireless Modbus I/O-0712ds page 1/5 Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII

More information

Coils & Electronic Controls

Coils & Electronic Controls HYDRAFORCE Coils & Electronic Controls COILS FOR SOLENOID OPERATED VALVES Standard Coils and Proportional Valve Coils... 3.200.1 Series E Water/Weather Resistant Coils... 3.400.1 ELECTRONIC CONTROLS FOR

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter Installation Instructions CD-Pxx-00-0 Issue Date February 4, 006 CD-Pxx-00-0 Series Duct Mount CO Transmitter Application Requirements FCC Compliance Statement This equipment has been tested and found

More information

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING 1.0 General This specification covers the electrical characteristics and general

More information

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System DRTS-6 Advanced Protection Relay Test Set and Measurement System MULTI-TASKING EQUIPMENT DESIGNED FOR TESTING PROTECTION RELAYS, ENERGY METERS, TRANSDUCERS POWERFUL AND LIGHTWEIGHT HIGH ACCURACY: BETTER

More information

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control. Section 16680 VARIABLE SPEED DRIVE SYSTEMS OR AFD Part I - GENERAL I.01 Description A. This specification is to cover a complete adjustable frequency motor drive consisting of a pulse width modulated (PWM)

More information

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD) Drives 101 Lesson 3 Parts of a Variable Frequency Drive (VFD) This lesson covers the parts that make up the Variable Frequency Drive (VFD) and describes the basic operation of each part. Here is the basics

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 905U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 905U range of telemetry modules provide remote monitoring

More information

StatiVolt. Inverter UPS Systems. Features. Contents

StatiVolt. Inverter UPS Systems. Features. Contents Redundant, clean, sine-wave AC power ensures a high availability of mission-critical safety devices, instrumentation, alarms, controls and computers. Robust, StatiVolt UPS Systems are designed and built

More information

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications. LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications. Its compact size, high efficiency, excellent reliability together with easy

More information

1 INTRODUCTION ORDER CODE / INFORMATION

1 INTRODUCTION ORDER CODE / INFORMATION INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O

More information

SHORT FORM. Product Catalog. (800) time-mark.com

SHORT FORM. Product Catalog. (800) time-mark.com SHORT FORM Product Catalog (800) 862-2875 time-mark.com 3-Phase Monitor Relays Time Mark has a variety of 3-phase relays that can offer protection against phase loss, phase reversal, phase unbalance and

More information

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Industrial Environment AC-DC Converters >100 Watt W Series 120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Rugged 35 mm DIN-rail snap-fit design 3000 V AC input to

More information

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection: Utility Systems Technologies, Inc. Sag Fighter TM Deep Voltage Sag Protection: D e e p Vo l t a g e S a g P r o t e c t i o n For three phase application: Q u a l i t y P o w e r. B e t t e r B u s i n

More information

Switching Power Supply Type SPP1 60W Enclosed type

Switching Power Supply Type SPP1 60W Enclosed type Type SPP1 60W Enclosed type Universal AC input full range Short circuit protection Internal input filter High efficiency High average efficiency (meets ErP) Low stand-by power consumption CE, TUV, and

More information

MODEL AT-10 ANALOG TRANSMITTER

MODEL AT-10 ANALOG TRANSMITTER MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca

More information

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585) SC200 Series Signal Conditioner MNX10020, REV H 10/17/2012 1 CONTENTS SECTION 1: OVERVIEW... 4 Introduction... 4 Description... 4 Ordering Information... 4 Specifications... 5 Environmental... 5 Electrical...

More information

VELTRON II Microprocessor Based Pressure & Flow Smart

VELTRON II Microprocessor Based Pressure & Flow Smart VELTRON II Microprocessor Based Pressure & Flow Smart Transmitter Accurate airflow measurement for demanding applications Precision Airflow Measurement An ONICON Brand VELTRON II with Automatic Zeroing

More information

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company P2 Power Solutions Pvt. Ltd. An ISO 9001:2008 Company Quality Power within your Reach P2 Power Magnetics P2 Power Solutions Pvt. Ltd. P2 Power Solutions Pvt. Ltd. provides EMC and power quality solutions,

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - Timer - Delay-on-Make TDM / TDMH / TDML Series Relay contacts are isolated. The TDM Series is a delay-on-make timer that combines accurate digital circuitry with isolated, DPDT relay contacts in an industry

More information

+ 24V 3.3K - 1.5M. figure 01

+ 24V 3.3K - 1.5M. figure 01 ELECTRICITY ASSESSMENT 35 questions Revised: 08 Jul 2013 1. Which of the wire sizes listed below results in the least voltage drop in a circuit carrying 10 amps: a. 16 AWG b. 14 AWG c. 18 AWG d. 250 kcmil

More information

True. Why. Truly. Today s current green-energy movement has stimulated

True. Why. Truly. Today s current green-energy movement has stimulated Why True RMS Truly Matters Increasingly energy-efficient HVAC equipment is changing the way systems are maintained and making true-rms meters a must -have for every service professional. B y G r e g J

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters Series T Differential Pressure Transmitters The Series T family of differential pressure transmitters measure low pressures and feature low power consumption and a variety of analog signal outputs. A wide

More information

Analog Servo Drive. Continuous Current. Features

Analog Servo Drive. Continuous Current. Features Description Power Range The PWM servo drive is designed to drive three phase brushless motors with sine wave current at a high switching frequency. The drive requires two sinusoidal command signals with

More information