RSMFX-2R MULTIFUNCTIONAL

Size: px
Start display at page:

Download "RSMFX-2R MULTIFUNCTIONAL"

Transcription

1 Mounting and operating instructions

2 Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND CONNECTIONS 5 MOUNTING & OPERATING INSTRUCTIONS IN STEPS 6 OPERATING INSTRUCTIONS 8 Verification of installation instructions 9 MODBUS REGISTER MAPS 9 TRANSPORT AND STORAGE 11 WARRANTY AND RESTRICTIONS 11 MAINTENANCE

3 SAFETY AND PRECAUTIONS Read all the information, the datasheet, mounting and operating instructions and study the wiring and connection diagram before working with the product. For personal and equipment safety, and for optimum product performance, make sure you entirely understand the contents before installing, using, or maintaining this product. For safety and licensing (CE) reasons, unauthorised conversion and / or modifications of the product are inadmissible. The product should not be exposed to abnormal conditions, such as: extreme temperatures, direct sunlight or vibrations. Long-term exposure to chemical vapours in high concentration can affect the product performance. Make sure the work environment is as dry as possible; avoid condensation. All installations shall comply with local health and safety regulations and local electrical standards and approved codes. This product can only be installed by an engineer or a technician who has expert knowledge of the product and safety precautions. Avoid contacts with energised electrical parts; always treat the product as if it is live. Always disconnect the power supply before connecting, servicing or repairing the product. Always verify that you apply appropriate power supply to the product and use appropriate wire size and characteristics. Make sure that all the screws and nuts are well tightened and fuses (if any) are fitted well. Recycling of equipment and packaging should be taken into consideration and these should be disposed of in accordance with local and national legislation / regulations. In case there are any questions that are not answered, please contact your technical support or consult a professional. 3-11

4 PRODUCT DESCRIPTION The RSMFX-2R series are multifunctional room transmitters which measure temperature, relative humidity, concentration level and ambient light. They feature a wide of low voltage power supply and three analog/ modulating outputs. All parameters are accessible via Modbus RTU. ARTICLE CODES Code Supply Connection RSMFG-2R VDC / VAC ±1 3-wire RSMFF-2R VDC 4-wire INTENDED AREA OF USE Monitoring temperature, relative humidity and level in HVAC applications Suitable for residential and commercial buildings For indoor use only TECHNICAL DATA 3 analog / modulating outputs: 0 VDC mode: min. load 50 kω (R L 50 kω) 0 20 ma: max. load 500 Ω (R L 500 Ω) PWM (open-collector type): PWM Frequency: 1 khz, min. load 50 kω (R L 50 kω); PWM voltage level 3,3 VDC or 12 VDC Selectable temperature : 0 50 C Selectable relative humidity : 5 85 % Selectable : ppm Ambient light sensor with adjustable active and standby level Removable sensor for easy calibration and verification Compatible with SSCDM (Sentera Sensor Calibration Device) 3 LEDs for status indication Accuracy: ±0,4 C (0 50 C); ±3 % rh (5 85 % rh); ±30 ppm ( ppm ), depending on the selected parameter Enclosure: rear plate: plastic ABS, black (RAL 9004) front cover: ASA, ivory (RAL 9010) Protection standard: IP30 (according to EN 60529) Operating ambient conditions: temperature: 0 50 C rel. humidity: 5 85 % rh, (non-condensing) Storage temperature: C STANDARDS Low Voltage Directive 2014/35/EC; EN 60529:1991; EN :2011 EMC Directive 2014/30/EC; EN :2011, EN :2007, EN :2007, EN :2013, EN :2013 WEEE 2012/19/EC RoHs Directive 2011/65/EC 4-11

5 OPERATIONAL DIAGRAMS Analog output 1 [%] 100 Minimum Minimum alert Maximum alert Maximum Analog output 2 [%] Min Max 85 rh, [%] Out of Alert Within Alert Out of Analog output 3 [%] T, [ C] 50 0 Min Max 2000, [ppm] WIRING AND CONNECTIONS Article type RSMFF-2R RSMFG-2R VIN VDC VDC VAC ±10% GND Ground Common ground* AC ~* A Modbus RTU (RS485), signal A Modbus RTU (RS485), signal A /B Modbus RTU (RS485), signal /B Modbus RTU (RS485), signal /B AO1 Analog / modulating output 1 for temperature measurement (0 VDC / 0 20 ma / PWM) Analog / modulating output 1 for temperature measurement (0 VDC / 0 20 ma / PWM) GND Ground AO Common ground* AO2 Analog / modulating output 2 for relative humidity measurement (0 VDC / 0 20 ma / PWM) Analog / modulating output 2 for relative humidity measurement (0 VDC / 0 20 ma / PWM) GND Ground AO Common ground* AO3 Analog / modulating output 3 for measurement (0 VDC / 0 20 ma / PWM) Analog / modulating output 3 for measurement (0 VDC / 0 20 ma / PWM) GND Ground AO Common ground* Connections Spring contact terminal blocks, cable cross section: 1,5 mm 2 * Caution: Never connect the common ground of G type articles to other devices powered by a DC voltage. If an AC power supply is used with a unit on a Modbus network, the GND terminal should NOT BE CONNECTED to other units on the network or via the CNVT-USB-RS485 converter. This may cause permanent damage to the communication semiconductors and / or the computer! 5-11

6 MOUNTING & OPERATING INSTRUCTIONS IN STEPS Before you start mounting the RSMFX-2R, read carefully Safety and Precautions. Choose a smooth surface for installation (a wall, panel and etc.). Follow these steps: 1. Using a flat screwdriver, remove the front white cover by releasing the snap-fits on its both sides (see Fig. 1 Snap-fits release). 2. Insert the cables through the opening on the rear plate (See Fig. 2 Mounting dimensions.) 3. Using suitable fastening materials (not supplied), position the room sensor at least 1,5 m from the floor. When planning the installation, allow enough clearance for maintenance and service. Mount the sensor in a well-ventilated area. Mind the correct mounting position and unit dimensions. See Fig. 2 and Fig. 3. Fig. 1 Snap-fits release Fig. 2 Mounting dimension 59,8 2x Ø 6 9,8 74,5 104, ,6 70,5 104,5 Fig. 3 Mounting position Correct Incorrect Position at min. 1,5 m from the floor 6-11

7 5. RSMFX-2R MULTIFUNCTIONAL 4. Do the wiring according to the wiring diagram (see Fig. 4). Fig. 4 Wiring and connections Power supply Modbus RTU Analog / digital output 1 - T Analog / digital output 2 - rh Analog / digital output 3-5. Put back the cover snap it in. 6. Switch on the mains supply. Optional settings If your unit is the first or the last unit on the Modbus RTU network (see Example 1 and Example 2), enable the resistor via 3SModbus or Sensistant. If your device is not an end device, leave the disabled (default Modbus setting). Example 1 Example 2 Slave 1 RX ТX Master RX ТX Slave 2 Master Slave n Slave 1 Slave 2 Slave n ATTENTION If an AC power supply is used with any of the units on a Modbus network, the GND terminal should NOT BE CONNECTED to other units on the network or via the CNVT USB-RS485 converter. This may cause permanent damage to the communication semiconductors and / or the computer! ATTENTION Do not exceed the maximum power supply rating! Measure before installation! Unregulated 24 VAC supply units provide higher nominal output voltage and activate the integrated fuse protection. ATTENTION We advise you not to use G and F-type articles together on the same network. If G and F-type articles are used together on the same network, make sure you use separate power supplies for both types. Always connect different article types to separate AC transformers or use the same article version. CAUTION Do not expose to direct sunlight! 7-11

8 OPERATING INSTRUCTIONS Calibration procedure: No relative humidity and temperature sensor calibration is necessary. By default, the sensor element is self-calibrating. Optionally, the sensor element can be calibrated and verified manually via SSCDM. For this purpose, the sensor element is removable. More information is available in the SSCDM datasheet and mounting and operating instructions. Bootloader Thanks to the bootloader functionality, the sensor firmware can be updated via Modbus RTU communication. To enter Boot mode, put a jumper onto pins 3 and 4 of the P1 header and restart the power supply (see Fig. 5). Once Boot mode is activated, the firmware can be updated via SM Boot application (part of 3SModbus software suite) or Sensistant. Fig. 5 P1 header Put a jumper onto pins 1 and 2 and wait for at least 5 seconds to reset the Modbus communication parameters Put a jumper onto pins 3 and 4 and restart the supply to enter bootloader mode LED indications 1. When the green LED is on, the measured value (temperature, relative humidity or ) is between the minimum and maximum alert values (Fig. 6-1). 2. When the yellow LED is on, the measured value (temperature, relative humidity or ) is in the alert (Fig. 6-2). 3. When the red LED is on, the measured value (temperature, relative humidity or ) is below the minimum measurement value or above the maximum value. Blinking red LED indicates loss of communication with a sensor (Fig ). Fig. 6 LED indications NOTE By default, the LED indication refers to temperature measurements. This can be changed to relative humidity or values via Modbus Holding Register 26 (see Table Holding registers below). 8-11

9 Ambient light sensor The measured light intensity in luxes is available in Input Register 5. Additionally, an active and standby level can be defined in Holding registers 34 and 35. Input Register 6 indicates if the measured value is below standby level, above active level or in between both levels: If the measured light level is below the Standby level, Input Register 6 indicates Standby. If the measured ambient light level is above the Active level, Input Register 6 indicates Active. If the measured ambient light level is between the active and stand-by level, Input Register 6 indicates Low intensity. When this feature is used, it is advisable to adjust the active and standby levels in Holding Registers 34 and 35 according to the actual ambient light conditions around the sensor. VERIFICATION OF INSTALLATION INSTRUCTIONS After switching on the power supply one of the LEDs lights up according to the status of the measured variable. If this is not the case, check the connections. MODBUS REGISTER MAPS INPUT REGISTERS Data type Description Data Values 1 Temperature signed int. Actual temperature level ,0 C 2 Relative humidity Actual relative humidity level , rh 3 Dew point signed int. Calculated dew point ,0 C 4 Actual level ppm 5 Ambient light intensity Measured light intensity lx 6 Active / standby 7 10 Reserved, return Analog output value 1 (temperature) Analog output value 2 (relative humidity) Active or Standby indication according the Active / Standby light level defined via holding registers 34 and 35. If the measured light level is between the two levels, the indication is 0 (Low intensity) 0 2 Analog output value for temperature (T).000 Analog output value for relative humidity (rh) Analog output value 3 ( ) Analog output value for Temperature alert flag 15 Relative humidity alert flag 16 alert flag 17 Temperature limit flag 18 Relative humidity limit flag 19 limit flag 20 Humidity / temperature sensor fault 21 Sensor fault 22 Ambient light sensor fault Flag indicates that measured temperature is outside set alert values. Set to 1 when the measured value is outside the temperature alert values defined by holding registers 20 and 21 Flag indicates that measured relative humidity is outside set alert values. Set to 1 when the measured value is outside the relative humidity alert values defined by holding registers 22 and 23 Flag indicates that measured level is outside set alert values. Set to 1 when the measured value is outside the limit values defined by holding registers 24 and 25 Flag indicates that measured temperature is outside set limit values. Set to 1 when the measured value is outside the temperature limit values defined by holding registers 14 and 15 Flag indicates that measured relative humidity is outside set limit values. Set to 1 when the measured value is outside the relative humidity limit values defined by holding registers 16 and 17 Flag indicates that measured level is outside set limit values. Set to 1 when the measured value is outside the values defined by holding registers 18 and 19 Flag indicates if the communication with the temperature and humidity sensor is lost Flag that shows if the communication with the sensor is lost Flag that shows if the communication with the ambient light sensor is lost Low light intensity Active Standby Measured temperature is OK Measured temperature is too high/ low Measured rh is OK Measured rh is too high/ low Measured is OK Measured is too high/ low Temperature is OK Temperature is too high/ low rh is OK rh is too high/ low is OK is too high/ low No Yes No Yes No Yes 9-11

10 HOLDING REGISTERS Data type Description Data Default Values 1 Device slave address Modbus device address Modbus baud rate Modbus communication baud rate Modbus parity mode Parity check mode Device type Device type (Read only) RSMFX-2R = HW version Hardware version of the device (Read only) XXXX 0x010 HW version FW version Firmware version of the device (Read only) XXXX 0x010 FW version Reserved, returns 0 8 Output 1 overwrite (T) Enables the direct control over the temperature output. 0 9 Output 2 overwrite (rh) Enables the direct control over the rh output 0 10 Output 3 overwrite ( ) Enables the direct control over the output 0 11 Output 1 type (T) Select analog / digital output type Output 2 type (rh) Select analog / digital output type Output 3 type ( ) Select analog / digital output type Minimum temperature Maximum temperature Minimum relative humidity Maximum relative humidity 18 Minimum 19 Maximum Minimum temperature alert Maximum temperature alert Minimum relative humidity alert Maximum relative humidity alert Minimum value of the temperature ; cannot be set higher than max. temperature minus 5ºC Maximum value of temperature ; cannot be set lower than min. temperature plus 5ºC Minimum value of the rh ; cannot be set higher than max. rh minus 5 % Maximum value of rh ; cannot be set lower than min. rh plus 5% Minimum value of the ; cannot be set higher than max. minus 100 ppm Maximum value of ; cannot be set lower than min. plus 100 ppm Minimum temperature alarm value Maximum temperature alarm value Minimum relative humidity alarm value Maximum relative humidity alarm value 3 = 4 = 5 = 6 = 3 = 3 = 3 = N1 8E1 8O1 Disabled Enabled Disabled Enabled Disabled Enabled 1 10 VDC 0 20 ma PWM 1 10 VDC 0 20 ma PWM 1 10 VDC 0 20 ma PWM 0 (Max. 50) ,0 C (Min. + 50) ,0 C 50 (Max. 50) , rh (Min. + 50) = 85, rh 0 (Max. 100) ppm (Min ) ppm Min. temperature Max. temperature alarm Min. temperature alarm Max. temperature Min. relative humidity Max. relative humidity alarm Min. relative humidity alarm Max. relative humidity ,0 ºC ,0 ºC , rh , rh 24 Minimum alert Minimum alarm value Min. Max. alarm ppm 25 Maximum alert Maximum alarm value Min. alarm Max. 26 LED indication LED indication related to one of the parameters Internal voltage source selection Output 1 (T) Internal voltage source selection Output 2 (rh) Internal voltage source selection Output 3 ( ) Modbus network resistor termination () Output 1 overwrite value (T) Output 2 overwrite value (rh) Output 3 overwrite value ( ) Selection of internal voltage source for PWM output 1 0 Selection of internal voltage source for PWM output 2 0 Selection of internal voltage source for PWM output Active level 35 Standby level 36 Modbus registers reset 37 module self calibration (ABC logic) algorithm Reserved, return 0 Set device as ending the line or not by connecting Overwrite value for output 1. Active only if Holding register 8 is set to 1 Overwrite value for output 2. Active only if Holding register 9 is set to 1 Overwrite value for output 3. Active only if Holding register 10 is set to 1 The ambient light level above which Active is indicated in input register 6 The ambient light level below which Standby is indicated in input register 6 Resets Modbus Holding registers to default values. When finished this register is automatically reset to 0 Enables or disables the module self-calibration algorithm. If enabled, the sensor will typically reach its operational accuracy after 24 hours of continuous operation. The sensor will maintain its accuracy given that it is exposed to a reference level of 400 ppm at least once in a 7 day period ppm 3 = temperature rh 3,3 VDC 12 VDC 3,3 VDC 12 VDC 3,3 VDC 12 VDC disconnected connected lx lx 0 1 If you want to find out more about Modbus over serial line, please visit: Idle Reset Modbus registers Disabled Enabled 10-11

11 TRANSPORT AND STORAGE Avoid shocks and extreme conditions; stock in original packing. WARRANTY AND RESTRICTIONS Two years from the delivery date against defects in manufacturing. Any modifications or alterations to the product after the date of publication relieve the manufacturer of any responsibilities. The manufacturer bears no responsibility for any misprints or mistakes in this data. MAINTENANCE In normal conditions this product is maintenance-free. If soiled, clean with a dry or damp cloth. In case of heavy pollution, clean with a non aggressive product. In these circumstances the unit should be disconnected from the supply. Pay attention that no fluids enter the unit. Only reconnect it to the supply when it is completely dry

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions ELECTRONIC FAN SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5

More information

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

MTV-1-CP 230 VAC POTENTIOMETER WITH MIN & MAX SETTINGS, DRY CONTACT. Mounting and operating instructions

MTV-1-CP 230 VAC POTENTIOMETER WITH MIN & MAX SETTINGS, DRY CONTACT. Mounting and operating instructions & MAX SETTINGS, DRY CONTACT Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 WIRING

More information

DTAP. universal programmable controller. Универсален програмируем контролер

DTAP. universal programmable controller. Универсален програмируем контролер dtap DTAP Универсален програмируем контролер universal programmable controller The DTAPG universal programmable controller provides a temperature and/or an analog input (0-10 VDC/0-20 ma/pwm) and a user-defined

More information

DP2500 DP0100 DP0250 Differential Pressure Transmitter

DP2500 DP0100 DP0250 Differential Pressure Transmitter PB_DPT_03 2010 DP2500 DP0100 DP0250 Differential Pressure Transmitter The DP Low Differential Pressure Transmitter series is an accurate and cost competitive solution for measuring low pressures of air

More information

Warning! ESD sensitive device!

Warning! ESD sensitive device! Datasheet & Manual SenseAir S8 Miniature CO2 sensor Model SE-0031 3.2% CO2 Warning! ESD sensitive device! Document PSP 108 Key technical specifications Item Target gas Operating Principle SenseAir S8 CO2

More information

S8 Residential pin header

S8 Residential pin header Product Specification S8 Residential pin header Miniature infrared CO sensor module Item S8 Residential pin header Article no. 004-0-0056 Target gas CO Operating Principle Measurement range Measurement

More information

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application STR-LCF Electronic Fan Coil Thermostat (Flush mounting) Datasheet Subject to technical alteration Issue date: 28.2.217 Application The fan coil room thermostat has been designed for individual control

More information

WIRELESS MODBUS GATEWAY WGW410

WIRELESS MODBUS GATEWAY WGW410 WIRELESS MODBUS GATEWAY WGW410 The Tekon Wireless Modbus Gateway WGW410 is specifically designed to meet the most rigorous requirements of operation in the industrial process environments. Due to their

More information

Senseair S8 Commercial

Senseair S8 Commercial Product Specification Senseair S8 Commercial Miniature infrared CO 2 sensor module 1 (8) Item Senseair S8 Commercial Article No. 004-0-0010, 004-0-0075 Target gas CO 2 Operating Principle Non-dispersive

More information

Gas and Air Sensors. Product Specification. SenseAir. Miniature CO2 sensor

Gas and Air Sensors. Product Specification. SenseAir. Miniature CO2 sensor Gas and Air Sensors Product Specification SenseAir S8 Miniature CO2 sensor SenseAir S8 Miniature infrared CO 2 sensor module Warning! ESD sensitive device! Figure 1. SenseAir S8 Article no. 004-0-0050

More information

Product Specification. SenseAir S8 LP. Miniature infrared CO 2 sensor module. Document PSP 126. Rev 8. Page 1 (8)

Product Specification. SenseAir S8 LP. Miniature infrared CO 2 sensor module. Document PSP 126. Rev 8. Page 1 (8) Product Specification SenseAir S LP Miniature infrared CO 2 sensor module 1 () Item SenseAir S LP Article no. 004-0-0053 Target gas CO 2 Operating Principle Non-dispersive infrared (NDIR) Measurement range

More information

Product Specification. SenseAir S8 LP. Miniature infrared CO 2 sensor module. Document PSP 126. Rev 4. Page 1 (10)

Product Specification. SenseAir S8 LP. Miniature infrared CO 2 sensor module. Document PSP 126. Rev 4. Page 1 (10) Product Specification SenseAir S8 LP Miniature infrared CO 2 sensor module Document PSP 126 Rev 4 Page 1 (10) SenseAir S8 LP Miniature infrared CO 2 sensor module Warning! ESD sensitive device! Figure

More information

Product Specification SenseAir S8

Product Specification SenseAir S8 Product Specification SenseAir S8 Miniature CO 2 Sensor module Driesen + Kern GmbH SenseAir S8 Miniature infrared CO 2 sensor module Warning! ESD sensitive device! Figure 1. SenseAir S8 Article no. 004-0-005

More information

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual T3110 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual Instruction manual for use of T3110 transmitter Transmitter

More information

Gas and Air Sensors. Product Specification. SenseAir S8. Miniature CO2 sensor. Document PSP 107. Rev 8. Page 1 (10)

Gas and Air Sensors. Product Specification. SenseAir S8. Miniature CO2 sensor. Document PSP 107. Rev 8. Page 1 (10) Gas and Air Sensors Product Specification SenseAir S8 Miniature CO2 sensor 8 1 (10) SenseAir S8 Miniature infrared CO 2 sensor module Warning! ESD sensitive device! Figure 1. SenseAir S8 Article no. 004-0-0013

More information

DP2500 DP0100 DP0250 Differential Pressure Transmitter

DP2500 DP0100 DP0250 Differential Pressure Transmitter PB_DP_03 2011 DP2500 DP0100 DP0250 Differential Pressure Transmitter The DP Low Differential Pressure Transmitter series is an accurate and cost competitive solution for measuring low pressures of air

More information

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output www.cometsystem.com Instruction Manual T5140 T5141 T5145 Programmable transmitter of CO2 concentration with 4-20 ma output T5240 T5241 T5245 Programmable transmitter of CO2 concentration with 0-10 V output

More information

SenseAir S8 Miniature infrared CO 2 sensor module

SenseAir S8 Miniature infrared CO 2 sensor module SenseAir S SenseAir S Miniature infrared CO 2 sensor module Warning! ESD sensitive device! SenseAir S Article no. 004-0-0010 SenseAir S Article no. 004-0-0011 2 (10) Item Target gas Operating Principle

More information

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual T3110 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual Instruction manual for use of T3110 transmitter Transmitter

More information

Modbus communication module for TCX2: AEX-MOD

Modbus communication module for TCX2: AEX-MOD Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Data sheet and manual. SenseAir S8. Alarm 5% Miniature infrared CO 2 sensor module

Data sheet and manual. SenseAir S8. Alarm 5% Miniature infrared CO 2 sensor module Data sheet and manual SenseAir S8 Alarm 5% Miniature infrared CO 2 sensor module Key technical specification Item SenseAir S8 Alarm 5% Article no. 004-0-001 Target gas CO 2 Operating Principle Non-dispersive

More information

CONTENTS XV300K GB r doc XV300K 2/13

CONTENTS XV300K GB r doc XV300K 2/13 XV300K CONTENTS 1 PRELIMINARY CHECK GUARANTEE RECYCLING... 3 2 XV300K SPECIFICATIONS OF USE... 3 3 CODES - MODELS... 4 4 TECHNICAL SPECIFICATIONS... 4 5 STANDARD REFERENCES... 5 6 MECHANICAL INSTALLATION...

More information

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual T0213 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual Instruction manual for use of T0213 transmitter

More information

MV110-8AS. Analog input module 8 channel. User guide

MV110-8AS. Analog input module 8 channel. User guide MV110-8AS Analog input module 8 channel User guide MV110-8AS_2016.12_0226_EN All rights reserved Subject to technical changes and misprints Contents 1 Description... 2 1.1 Function... 2 1.2 RS485 network...

More information

Gas and Air Sensors. Product Specification. SenseAir S8. Miniature CO 2 sensor module

Gas and Air Sensors. Product Specification. SenseAir S8. Miniature CO 2 sensor module Gas and Air Sensors Product Specification SenseAir S8 Miniature CO 2 sensor module SenseAir S8 Miniature infrared CO 2 sensor module Warning! ESD sensitive device! Figure 1a. SenseAir S8 Article no. 004-0-0013

More information

CDG. Carbon Dioxide - User Manual Gas Detector. 1 Intended Use. 2 Functional Description. 3 Installation. 4 Electrical Connection.

CDG. Carbon Dioxide - User Manual Gas Detector. 1 Intended Use. 2 Functional Description. 3 Installation. 4 Electrical Connection. Carbon Dioxide - User Manual 1 Intended Use 2 Functional Description 2.1 Control Mode 2.2 Sensor 3 Installation 3.1 Mounting instructions 3.2 Installation 4 Electrical Connection 4.1 Instruction 5 Commissioning

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Driesen + Kern GmbH. Product Specification. SenseAir S8. Commercial. Miniature infrared CO 2 sensor module. Document Rev Page 1 (10)

Driesen + Kern GmbH. Product Specification. SenseAir S8. Commercial. Miniature infrared CO 2 sensor module. Document Rev Page 1 (10) Driesen + Kern GmbH Product Specification SenseAir S8 Commercial Miniature infrared CO 2 sensor module 1 (10) SenseAir S8 Commercial Miniature infrared CO 2 sensor module Warning! ESD sensitive device!

More information

Driesen + Kern GmbH. Product Specification. SenseAir S8. Miniature CO 2 sensor. Document PSP 113. Rev 3. Page 1 (12)

Driesen + Kern GmbH. Product Specification. SenseAir S8. Miniature CO 2 sensor. Document PSP 113. Rev 3. Page 1 (12) Driesen + Kern GmbH Product Specification SenseAir S8 Miniature CO 2 sensor 1 (12) SenseAir S8 Miniature infrared CO 2 sensor module Warning! ESD sensitive device! Figure 1. SenseAir S8 Article no. 004-0-0017

More information

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual D.C. BRUSHLESS MOTORS DRIVE BLD07-IT Service Manual INTECNO s.r.l. Via Caduti di Sabbiuno n. 9/E 40011 Anzola Emilia (BO) - Italy tel. 051.19985350 fax 051.19985360 www.intecno-srl.com INDEX Description

More information

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical specifications - Installation rules - Electrical connections - Modbus connection rules - DIP-switches settings -

More information

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter Installation Instructions CD-Pxx-00-0 Issue Date February 4, 006 CD-Pxx-00-0 Series Duct Mount CO Transmitter Application Requirements FCC Compliance Statement This equipment has been tested and found

More information

MU110-8R(K) Digital output module 8 channel. User guide

MU110-8R(K) Digital output module 8 channel. User guide MU110-8R(K) Digital output module 8 channel User guide MU110-8R(K)_2019.01_0296_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Germany

More information

T5340, T5341, T5440, T5441 T6340, T6341, T6440, T6441

T5340, T5341, T5440, T5441 T6340, T6341, T6440, T6441 Programmable transmitter of CO2 concentration T5340, T5341, T5440, T5441 Programmable transmitter of temperature, relative humidity, CO2 and other derived humidity values T6340, T6341, T6440, T6441 with

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

Antenna Splitter ASA 1. Instruction manual

Antenna Splitter ASA 1. Instruction manual Antenna Splitter ASA 1 Instruction manual Contents Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Combination possibilities of ASA 1/ASA 1-1G8... 5 Delivery includes...

More information

Driesen + Kern GmbH. SenseAir S8

Driesen + Kern GmbH. SenseAir S8 SenseAir S8 SenseAir S8 Miniature infrared CO 2 sensor module Warning! ESD sensitive device! SenseAir S8 Article no. 004-0-0050 SenseAir S8 Article no. 004-0-0051 2 (10) Key technical specification Item

More information

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00 NetBiter I/O Extender 4RO 6RTD 8DIO DAIO User Manual Revision 1.00 IntelliCom Innovation AB Linjegatan 3D SE302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 18 21 99 email info@intellicom.se www

More information

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual T3110 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual Instruction manual for use of T3110 transmitter Transmitter

More information

THT2. Intelligent sensor. Humidity measuring range: 0 to 100 % Temperature measuring range: 40 to +125 C. Dew point automatic calculation

THT2. Intelligent sensor. Humidity measuring range: 0 to 100 % Temperature measuring range: 40 to +125 C. Dew point automatic calculation Intelligent sensor Humidity measuring range: 0 to 100 % Temperature measuring range: 40 to +125 C Dew point automatic calculation Communication via RS485 line Removable sensor 2. July 2018 w w w. p a p

More information

Table of Contents. HWIO-Gateway User Manual

Table of Contents. HWIO-Gateway User Manual User Manual HWIO-Gateway INUX AB Katrinedalsg. 3, 504 51 Borås http://www.inux.se Copyright 2009 Uppdaterad 2010-01-12 Copyright 2009 INUX AB 1 Table of Contents 1. Product overview...3 2. License...3

More information

Installation instructions

Installation instructions Installation instructions T70RX-03AIB, T70RX-03AWB, T70TX-02TTB, T70TX-03STB, T70TX-06TTB LANGUAGE: English (original) IM-T70-RX001-A01-EN CONTENTS Chapter 1: CUSTOMER INFORMATION 3 Chapter 2: PRODUCT

More information

User Manual. PolyGard AT-2000 V3. Infrared Refrigerant Gas Transmitter Serial No. AT March, 2009

User Manual. PolyGard AT-2000 V3. Infrared Refrigerant Gas Transmitter Serial No. AT March, 2009 PolyGard AT-2000 V3 Infrared Refrigerant Gas Transmitter Serial No. AT-2000 User Manual March, 2009 February 16, 2016 Revision Specifications subject to change without notice. USA 160216 Page 2 of 13 1

More information

Power Genius XL User Manual rev 10.

Power Genius XL User Manual rev 10. Power Genius X User Manual rev 10. 1/23 Table of Contents 0. Important notice...3 1. Unpacking...5 1.1. Front Panel...5 1.2. Back Panel...6 1.3. BCD/PTP connector pinout...8 2. Using with Radios...9 2.1.

More information

F2A3X Frequency to Analog Converter Module

F2A3X Frequency to Analog Converter Module the professional s choice F2A3X Frequency to Analog Converter Module Instruction Manual MONARCH INSTRUMENT 15 Columbia Drive Amherst, NH 03031 USA Phone: (603) 883-3390 Fax: (603) 886-3300 E-mail: support@monarchinstrument.com

More information

JBUS/MODBUS communication card

JBUS/MODBUS communication card JBUS/MODBUS communication card JBUS/MODBUS Installation and user manual 66061 51029066EN/BF - Page 1 Page 2-51029066EN/BF Introduction Thank you for selecting an APC by Schneider Electric product to protect

More information

MU110-16R(K) Digital output module 16 channel. User guide

MU110-16R(K) Digital output module 16 channel. User guide MU110-16R(K) Digital output module 16 channel User guide MU110-16R(K)_2016.12_0220_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Germany

More information

ENGLISH S-CO2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS CO 2. TF5701_B_v1_web

ENGLISH S-CO2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS CO 2. TF5701_B_v1_web S-CO2 CO 2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS ENGLISH TF5701_B_v1_web 1 DESCRIPTION This module measures carbon dioxide (CO 2 ) in the range of 0 to 2 000 ppm and is equipped with

More information

PLC-K506 Series FEATURES DESCRIPTION FEATURES

PLC-K506 Series FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs Inputs 10 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate With Up to 32 Devices DESCRIPTION

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual T3111 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual Instruction manual for use of T3111 transmitters Transmitter

More information

AxCent Servo Drive A50A100

AxCent Servo Drive A50A100 Description Power Range The A50A100 PWM servo drive is designed to drive brushed type DC motors at a high switching frequency. A single red/green LED indicates operating status. The drive is fully protected

More information

MK110-8D.4R. Digital I/O-Module 12 channel 8 DI, 4 DO. User guide

MK110-8D.4R. Digital I/O-Module 12 channel 8 DI, 4 DO. User guide MK110-8D.4R Digital I/O-Module 12 channel 8 DI, 4 DO User guide MK110-8D4R_2016.12_0219_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover

More information

S11 Adjustable Speed Drive Engineering Specification

S11 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba S11 AC Variable Frequency Drives, 6 pulse for 3- phase 200-240VAC, 380-500VAC and single phase 200V to 240VAC. 1.1 References A. National

More information

Industrial motor controller for brushed DC motors 12 VDC

Industrial motor controller for brushed DC motors 12 VDC Industrial motor controller for brushed DC motors 12 VDC Design for output currents up to 5 A Control with the following functions: - reversal of direction of rotation - rotational speed control (external)

More information

Output Signal Active Note. Output Signal Temperature 22UTH-51 DC V, DC V

Output Signal Active Note. Output Signal Temperature 22UTH-51 DC V, DC V Outdoor Humidity, Temperature Sensor ±2% accurate humidity and temperature sensor for outdoor applications. Temperature is available with dual active 4 to 20 ma outputs or passive only for temperature.

More information

8V General information. 2 Order data 8V

8V General information. 2 Order data 8V 8V80.00-8V80.00- General information Modular mechanical design using plug-in modules Integrated line filter Integrated or optional external braking resistor All connections are made using plug-in connectors

More information

Industrial motor controller for brushed DC motors 24 VDC

Industrial motor controller for brushed DC motors 24 VDC Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 5 A Control with the following functions: - reversal of direction of rotation - open-loop speed control (external)

More information

Precipition Sensor with analogue Intensity Output ,

Precipition Sensor with analogue Intensity Output , THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 021335/11/09 Precipition Sensor with analogue Intensity Output 5.4103.20.041, 5.4103.20.741 ADOLF THIES

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

AMM-1022 Digital Multimeter USER`S MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement

More information

ITP14. Universal process indicator. User guide

ITP14. Universal process indicator. User guide ITP14 Universal process indicator User guide ITP14_2018.05_0279_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Germany Tel.: +49 (0)

More information

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs Inputs 10 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate with up to 32 devices DESCRIPTION

More information

Analog Servo Drive 25A20DD

Analog Servo Drive 25A20DD Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information

Astra-R Kit Wireless Alarm System Operation Manual

Astra-R Kit Wireless Alarm System Operation Manual Astra-R Kit Wireless Alarm System Operation Manual This operation manual describes principles of functioning, proper use, maintenance and service for the wireless alarm system Astra- R Kit (Figure 1).

More information

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3 CHAPTER INSTALLATION 2 AND WIRING Contents of this Chapter... Ambient Conditions..............................2 2 Storage Conditions...............................2 2 Installation.....................................2

More information

AxCent Servo Drive A25A100

AxCent Servo Drive A25A100 Description Power Range The A25A100 PWM servo drive is designed to drive brush type DC motors at a high switching frequency. A single red/green LED indicates operating status. The drive is fully protected

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

Installation and Operating Manual

Installation and Operating Manual GB Analog Weight Transmitter PS-1000 Installation and Operating Manual LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section

More information

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 o RMS AC current or frequency measurements o Current auto range measurements up to 12 A o Frequency measurement range 16 400 Hz

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Precipitation Monitor ,

Precipitation Monitor , THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 021197/11/09 Precipitation Monitor 5.4103.10.000, 5.4103.10.700 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

PROCESS & TEMPERATURE CONTROLLERS

PROCESS & TEMPERATURE CONTROLLERS PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs

More information

Magnetic Inductive Flow Sensor induq

Magnetic Inductive Flow Sensor induq Operating manual (Translation) Operating manual... page 1-16 Magnetic Inductive Flow Sensor induq Series VMZ SIKA Ba_VMZ_en 10/2014. Please keep this operating manual for future reference. If the device

More information

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL Roline L1 Series Humidity - Temperature Transmitters INSTRUCTION MANUAL 20030314 CONTENTS Overview... 3 Operation... 5 Power supply... 5 Operating range and limits... 5 Temperature compensation of the

More information

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors. SilverMax Datasheet NEMA 23 Servomotors QuickSilver Controls, Inc. www.quicksilvercontrols.com SilverMax Datasheet - NEMA 23 Servomotors 23 Frame Sizes: 23-3, 23-5, 23H-1, 23H-3, 23H-5 / Series: E, E3,

More information

M211748EN-F. User Guide. Vaisala CARBOCAP Carbon Dioxide, Humidity and Temperature Transmitters. GMW80 Series

M211748EN-F. User Guide. Vaisala CARBOCAP Carbon Dioxide, Humidity and Temperature Transmitters. GMW80 Series M211748EN-F User Guide Vaisala CARBOCAP Carbon Dioxide, Humidity and Temperature Transmitters GMW80 Series PUBLISHED BY Vaisala Oyj Street address: Vanha Nurmijärventie 21, FI-01670 Vantaa, Finland Mailing

More information

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10 CONTENTS 1. SAFETY INFORMATION.1 2. DESCRIPTION..4 3. SPECIFICATIONS.6 4. OPERATING INSTRUCTION..9 4.1 Voltage measurement...10 4.2 Current measurement 10 4.3 Resistance measurement...12 4.4 Diode test.12

More information

Industrial motor controller for brushed DC motors 24 VDC

Industrial motor controller for brushed DC motors 24 VDC Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 5 A Control with the following functions: - reversal of direction of rotation - open-loop speed control (external)

More information

MV110-8A. Analog input module 8 channel. User guide

MV110-8A. Analog input module 8 channel. User guide MV110-8A Analog input module 8 channel User guide MV110-8A_2016.12_0225_EN All rights reserved Subject to technical changes and misprints Contents 1 Description... 2 1.1 Function... 2 1.2 RS485 network...

More information

PLUS WGW420 WIRELESS GATEWAY 868MHz

PLUS WGW420 WIRELESS GATEWAY 868MHz PLUS WGW420 WIRELESS GATEWAY 868MHz REF.: PA164510210 An easy-to-use system that allows wireless reception and transmission of any process variables that could be transformed into an analogue signal. PLUS

More information

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL M1 Series Humidity - Temperature Transmitter INSTRUCTION MANUAL 20031110 -2- CONTENTS Overview... 3 Operation... 4 Power supply... 4 Operating range and limits... 4 Temperature compensation of the humidity

More information

Analog Servo Drive 20A20

Analog Servo Drive 20A20 Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information

Type Overview. Technical Data. Outdoor Humidity, Temperature Sensor

Type Overview. Technical Data. Outdoor Humidity, Temperature Sensor Outdoor Humidity, Temperature Sensor ±2% accurate humidity and temperature sensor for outdoor applications. Temperature is available with dual active 4 to 20 ma outputs or passive only for temperature.

More information

ELECTRONIC FAN SPEED CONTROL

ELECTRONIC FAN SPEED CONTROL ELECTRONIC FAN SPEED CONTROL Our electronic speed controllers are based on the principle of phase angle control by means of triacs. They are applicable for the adjustment of single phase voltage controllable

More information

Programmable AC Voltage Transducer MT416

Programmable AC Voltage Transducer MT416 Programmable AC Voltage Transducer MT416 RMS AC voltage or frequency measurements Voltage auto measurements up to 600 V L-N Frequency measurement 16 400 Hz AC or universal wide auiliary power 24 300 Vdc,

More information

Series 10-ZSE30A(F)/10-ISE30A

Series 10-ZSE30A(F)/10-ISE30A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H

More information

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE OPERATION & SERVICE MANUAL FOR FC 100 SERIES AC POWER SOURCE FC 110 AC POWER SOURCE VERSION 1.3, April 2001. copyright reserved. DWG No. FC00001 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 1.1 GENERAL...

More information

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D T8211D 1 1. SAFETY INFORMATION BE EXTREMELY CAREFUL IN THE USE OF THIS METER. Improper use of this device can result in electric shock or destroy of

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING

More information

Output Signal Active Temperature. Electrical data Power Supply DC V, ±10%, 0.5 W

Output Signal Active Temperature. Electrical data Power Supply DC V, ±10%, 0.5 W Duct Sensor Humidity / Temperature Active sensor (4...20 ma) for measuring the relative or absolute humidity and temperature in duct applications. Instead of the humidity signal, the enthalpy or the dewpoint

More information

Submittal 420I Converter

Submittal 420I Converter Submittal 420I Converter Application: The 420I communicates digitally with transmitters (201T, 301D and SQN8X), within a true daisy chain network, to convert the transmitters digital signals to analog

More information

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section

More information

DVC700 Series Programmable System Controller

DVC700 Series Programmable System Controller LC Programmed with HCT s Intella Software Suite 14 I/O (8 inputs & 6 outputs), 1 CAN interface Supply voltage 9-30Vdc The is a robust programmable controller for solenoid-operated proportional valves.

More information

Programmable AC Current Transducer MT418

Programmable AC Current Transducer MT418 Programmable AC Current Transducer MT418 RMS AC current measurements Current auto range measurements up to 12 A Frequency measurement range 16 400 Hz AC or universal wide auiliary power supply range 24

More information

JBus/Modbus Communication Card

JBus/Modbus Communication Card JBus/Modbus Communication Card Installation and Operation 05/2018 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries

More information

8V General information. 2 Order data 8V

8V General information. 2 Order data 8V 8V05.00-8V05.00- General information Modular mechanical design using plug-in modules Integrated line filter Integrated braking resistor All connections are made using plug-in connectors Integrated electronic

More information