Introduction... 3 Slits for AIR Operation... 4 Slits in Vacuum Vessels... 5 Slits for High Vacuum Operation... 6 Custom Slits... 7 Steel Slits...

Size: px
Start display at page:

Download "Introduction... 3 Slits for AIR Operation... 4 Slits in Vacuum Vessels... 5 Slits for High Vacuum Operation... 6 Custom Slits... 7 Steel Slits..."

Transcription

1

2 Introduction... 3 Slits for AIR Operation... 4 Slits in Vacuum Vessels... 5 Slits for High Vacuum Operation... 6 Custom Slits... 7 Steel Slits Non-magnetic Options for Slits Slits with Passive Cooling Slits for UHV Operation Slit Blades Slit Blades Quality Water Cooled Slits... 23

3 Over the last two decades, JJ X-Ray has delivered high precision slit systems to neutron and x-ray facilities all over the world. During the years, our portfolio has expanded significantly, to meet our customers needs. In this catalogue, we will present the large variety of our slit systems. For more details on specific sizes or other custom needs, please contact us directly by or visit our website. Basically, our slit systems are defined by blade motion, position of aperture, maximum aperture and slit operation environment. Blade motion: Individual Blades (IB) or Aperture Translation (AT) Position of Aperture in slit body: Centered (C), Off-Center (F), Asymmetric (A) Maximum Aperture Opening in mm Slit Operation: In air (AIR), in high vacuum (HV) or in ultra-high vacuum (UHV) Using this naming convention, our slits are named according to the following system: In addition to the above functionalities, we offer a wide range of options: Cooling, drain current, non-magnetic solutions, custom blades, encoders and DEMI-slits (a 2 blade slit) etc. In other words, we will do our best to meet all you specifications. 3

4 The AIR-slits represent a large variety of systems that are optimized to operate in air, and the materials are carefully chosen for their mechanical and radiation resistant properties. Our classic AT-F7-AIR slit developed by ESRF engineers and scientists. Two identical houses and a off-centered aperture. ATslit blades are translated in pair by one common motor, and the aperture is controlled by another motor. Also available in a vacuum version (AT-F7- HV). IB-C120-AIR has a large centered aperture and is typically used by neutron facilities. Four independently moveable blades defines the aperture size and position. 4

5 Many customers need to insert their slit systems inside larger vacuum vessels. In these cases, you will not need a slit system with flange connections (see our "Vacuum Slits") but rather a modified "AIR Slit". Occasionally, a beamline has extra sensible components such as mirrors or detectors in close vicinity of the slits. In these cases, extra precautions may be needed to avoid contamination. Depending on your vacuum pressure and instrumentation, you can either go all the way and have an AIR Slit for UHV or you can replace some of the critical parts in our standard AIR Slits. This is a modified version of our standard IB-C50-AIR. All parts and surfaces are suited for UHV operation (including microswitches, motors, wiring, connectors, guides and encoders). 5

6 Thousands of high vacuum JJ-slit systems are operating successfully at a large variety of neutron and synchrotron beamlines all around the world. They consist of low outgassing materials and are o-ring sealed. The systems are developed for 10-5 mbar vacuum operation and a significant part of these are also prepared for operating at vacuum lower than 10-5 mbar. AT-C8-HV is our most compact vacuum slit. It has a centered aperture and KF-25 flange connections. The blades are translated in pair by one common motor, and the aperture is controlled by another motor. IB-C30-HV has a 30x30 mm 2 aperture and is fitted with KF-40 flange connections. Four independently moveable blades defines the aperture size and position. 6

7 Sometimes, the limited space around the beamlines and special requirements for the aperture size makes it difficult for a standard square slit to fit into a specific instrumentation. In that case, we can design and produce a customized solution which is developed from our standard slit systems. An overview of our existing custom shaped slit designs are available on our website. IB-A30x100-AIR has a 30x100 mm 2 aperture and not fully overlapping blades. The rectangular shape makes it possible to fit it into a very compact setup. 7

8 A custom shaped slit system (IB-A40x60-AIR) with a base and a rectangular aperture. In addition, it contains ball screws to increase operational life. 8

9 2 blades slit systems : IB-A50x150-AIR-DEMI. IB-A60x100-AIR 9

10 Our standard slit houses are made of aluminum which is easy to process and handle. In a few cases, vacuum pressure might challenge precision and therefore, the standard aluminum house is replaced by a stainless steel house to reduce strain of lead screws and linear guides. Stainless steel is also possible where shielding of higher energies is required. Stainless steel version of AT-C8-HV. A welded steel version of IB-C150-HV. To reduce strain of lead screws and linear guides due to vacuum pressure, the standard aluminum house is replaced by a steel house. 10

11 FE analysis of the welded chamber for IB-C150-HV to simulate the deformation of the slit housing (15 mm thick) when it is under the influence of vacuum pressure. The pressure applied to the internal walls is hpa. The elastic modulus of SS 304 is 193 GPa. The result shows the maximum total displacement vector of 89.4 um located at the central part of the slit housing. 11

12 If a slit system needs to be positioned in close vicinity of a magnet, or if the beam is very sensitive to the magnetic fields, there are a range of options to reduce magnetism. IB-C160-AIR with extensions moving motors and rotary encoders 100 mm further away from the beam center. The system also contains non-magnetic guides, lead screws and screws. IB-C50-AIR with non-magnetic guides, screws and lead screws. A nonmagnetic solution, we offer for several of our larger AIR og HV slit systems. The chosen materials depends on the slit operation (AIR or HV). 12

13 Sometimes, the total power of the beam is slightly too high for a standard slit system. In many cases, it is enough to use passive cooling to solve the heat issue. At present, we have an AIR and HV version suitable for a heat load up to 5 Watt per blade. Thermocouples can be integrated for heat monitoring. If needed, JJ X-Ray offers heat transfer analysis to calculate the temperature based on a specific heat load. IB-C50-AIR-CL contains copper braids. In addition, ventilation holes are added to improve air circulation. IB-C30-HV-CL is sligthly larger in beam direction than the classic IB-C30-HV. This version contains copper braids as well as thermo couples. Extra connectors for the thermocouples are seen on the side of the motor house. 13

14 IB-C50-AIR-CL. The shown copper braids conduct the absorped heat from the slit blades to the aluminum housing. Heat transfer analysis was performed on IB-C50-AIR-CL. The beam size was calculated to 200 µm 2 and the heat source of 37.5 W was applied to the edge of the slit blades. Heat was removed from the slit blades using flexible copper braid (area = 6.0 mm 2, dimensions 10 mm x 1 mm, 0.15 mm wire dia.). The temperature on the outer surfaces of the slit was set to room temperature of 22 deg C. As a result, the maximum steady-state temperature was 162 C located at the heat source. This is acceptable for shorter periods of time e.g. during alignment. 14

15 To accommodate market demands for a reliable compact UHV slit (10-9 mbar for monochromatic applications), we have expanded our standard individualblade slit design into a UHV compatible slit system. Like the air and vacuum IB-slits, the aperture in the UHV version is defined by four independently movable and highly polished tungsten carbide blades. These blades are controlled by a high-precision in-vacuum guiding rail system. The guides are positioned close to the blades giving the shortest distance from the guide to the blade. We recommend the option with internal linear UHV compatible encoders in order to obtain precise knowledge about the actual blade position. Accuracy for IB-C30-UHV is ± 2 µm over 3 mm in open loop and <0.5 µm in closed loop. A large number of options can be applied to this model e.g. cooling, drain current, pin diode, alignment bases, extra view ports, custom blades and motors. 15

16 IB-C30-UHV with options: Pindiode and alignment base. The shown alignment base has the following motions: x and y directions, roll and pitch (Phi, Chi), and yaw (Theta). IB-C30-UHV with passive cooling option. Copper braids mounted between each blade and the steel chamber (cooled for operation up to 5 Watt per blade). Typically combined with thermocouples. The assembly of IB-C30-UHV takes place in our ISO 5 cleanroom 16

17 partial pressure [mbar] 1,00E-08 RGA on 1.2E-8mbar 1,00E-09 1,00E-10 1,00E-11 1,00E-12 1,00E-13 1,00E amu Summary Value Turbo Pump started pump only PrismaPlus RGA probe turned on Callibration Faraday scan SEM scan Pressure at scan time 1.4E-8 mbar Highest peak is AMU= E-10 mbar Inteval 20 to 44 are < 1E-2 of AMU(18) Passed Inteval 45 to 100 are < 1E-3 of AMU(18) Passed Pressure integral 1.80E-10 mbar Extract from our RGA Test. In addition to RGA testing, our UHV Slits go through a detailed testing sequence in closed and open loop operation. An example of a test report can be obtained. 17

18 Our slit blades are carefully selected and a wide range of materials as well as configurations are possible. Most common materials are Tungsten Carbide, Tantalum, Boron Carbide and single crystal blades (Si, GaAs or InP). Slit blade shapes include knife-edge, rectangular and cylindrical shapes. For single crystal blades, we normally use a 20 degree tapered angle. Standard 2 mm Tungsten Carbide blades for IB-C30-HV with a 0.5 degree knife-edge on one side and R16 cylinder shape on the other side. X-ray facilities The rectangular blade (no knife-edge): Will give a well-defined sharp blocking of the beam, but there may be a contribution of total reflectivity of the part of the blade that is parallel to the incoming beam. If the beam is very divergent, this may not be a problem. When working at higher energies and using e.g. 10 mm thick blades, we often recommend rectangular blades. Knife-edge blade: The alternative is to have a knife-edge. Here the blocking of the beam will not be as sharp, since there will be some transmission near the edge of the knife. On the other hand, you can avoid the total reflectivity from the blade. The cylindrical shape: Will also have some transmission near the edge, and there will in addition also be some total reflectivity near the tangent of the cylinder. But used for a guard slit/clean up slit, this sometimes limit the diffuse scattering from the blades. 18

19 Single crystal blades: are typically used for guard slits/clean up slits. Below 8-10 kev, we recommend single crystal Silicon blades. They have been tested at 8 kev at the P10 beamline, PETRA (SAXS beamline) where scattering was reduced by a factor of 100. At higher energies (above 10 kev), alternatives such as GaAs og InP are recommended. Single crystal blades can be used for high vacuum and ultra-high vacuum on request. Standard tungsten carbide blade Single crystal Si blade 19

20 The cylindrical super-polished blades: Are often used for beamlines with very high beam coherence such as FEL s. The blades are often configured in two successive slits. The first slit has blades with low-z cylinders (Si 3 N 4, SiC or B 4 C) and the second slit has blades high-z cylinders (WC, TaW). The first low-z slit serves as a guard for single-shot damage of the intense FEL pulses, and the second high-z slit serves as the stopping of higher energies. Tantalum (Ta90/W10) blade holder with a nano polished Si 3 N 4 cylinder and a Si 3 N 4 sheet. The cylinder is exposed to a 10-step polishing procedure to achieve an excellent surface. Best results are achived with tantalum (Ta90/W10) and Si 3 N 4. Neutron facilities: Blades used at neutron facilities are typically rectangular and our preferred material is B 4 C (natural Boron Carbide) or 10 B 4 C (enriched Boron Carbide). Blades can either be mounted by holes or clamps. 20

21 By using MarSurf PS1 measuring instrument, it is possible to control parameters as straightness of blade edge and surface roughness. The parallelism of slit blades may be quantified by laser interferometry. The example on next page shows a setup with a blade parallelism of 0,04mrad. Standard 2 mm tungsten carbide blades for IB-C30-HV. Straightness of polished tungsten carbide blade edge and surface roughness are measured using a MarSurf PS1 roughness measuring instrument 21

22 Diffraction intensity perpendicular to slit Pixels Slit-diffraction data and measurement regions Location of diffraction - minimal and fitted slit size Order Pixel location Intensity a.u. 22

23 Sometimes, water cooling is a necessary option for high power beams. For this purpose, we have developed a power slit with an aperture of 50 mm and a possible absorption of 400 Watt. It is suitable for ultra-high vacuum <1x10 9 mbar. For more information, please contact sales@jjxray.dk Water cooled slit blade component IB-C50-UHV-400W 23

24 Slit Systems (AIR,HV, UHV) Complete Beamline Solutions Spectrometers Refractive Optics Foil Collimators Positioning Contact JJ X-Ray A/S If you have any questions, concerns, request for quotations or need general advice, please feel free to contact us: JJ X-Ray A/S Scion-DTU, Dr. Neergaards Vej 5D 2970 Hoersholm Denmark Telephone: Fax: VAT: DK Website:

In its basic configuration, the slit is delivered with a flangeopening and four tightening bolts to allow connection with a KF-40 flange.

In its basic configuration, the slit is delivered with a flangeopening and four tightening bolts to allow connection with a KF-40 flange. The JJ X-Ray AT-C30-HV slit was developed for applications where relatively large apertures (up to 30 mm x 30 mm) and/or highly accurate slit-scans are required. Thus the AT- C30 is for customers appreciating

More information

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4 Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4 S.V. Roth, R. Döhrmann, M. Dommach, I. Kröger, T. Schubert, R. Gehrke Definition of the upgrade The wiggler beamline BW4 is dedicated to

More information

Workshop IGLEX Andromède & ThomX 23 June 2016, LAL Orsay. The X-line of ThomX.

Workshop IGLEX Andromède & ThomX 23 June 2016, LAL Orsay. The X-line of ThomX. Workshop IGLEX Andromède & ThomX 23 June 2016, LAL Orsay The X-line of ThomX jerome.lacipiere@neel.cnrs.fr mjacquet@lal.in2p3.fr Brightness panorama of X-ray (10-100 kev) sources Synchrotron : not very

More information

Historical. McPherson 15 Mount

Historical. McPherson 15 Mount McPherson 15 Mount Normal incidence designs include the McPherson 15 (classical 1.0 meter focal length) and modern NIM units. The latter features smaller included angles, longer focal lengths (e.g. 3,

More information

Micro-manipulated Cryogenic & Vacuum Probe Systems

Micro-manipulated Cryogenic & Vacuum Probe Systems Janis micro-manipulated probe stations are designed for non-destructive electrical testing using DC, RF, and fiber-optic probes. They are useful in a variety of fields including semiconductors, MEMS, superconductivity,

More information

Properties of Structured Light

Properties of Structured Light Properties of Structured Light Gaussian Beams Structured light sources using lasers as the illumination source are governed by theories of Gaussian beams. Unlike incoherent sources, coherent laser sources

More information

Supplementary Materials

Supplementary Materials Supplementary Materials In the supplementary materials of this paper we discuss some practical consideration for alignment of optical components to help unexperienced users to achieve a high performance

More information

The TSIS Spectral Irradiance Monitor: Prism Optical Degradation Studies

The TSIS Spectral Irradiance Monitor: Prism Optical Degradation Studies The TSIS Spectral Irradiance Monitor: Prism Optical Degradation Studies Lo Erik Richard, Dave Harber, Joel Rutkowski, Matt Triplett, Kasandra O Malia Laboratory for Atmospheric and Space Physics (LASP)

More information

Date: July 31, 2017 Title: Design of an Aperture Assembly for X-Ray Diffraction Student: Christina Schmidt Mentor: Dr. Peter Ko

Date: July 31, 2017 Title: Design of an Aperture Assembly for X-Ray Diffraction Student: Christina Schmidt Mentor: Dr. Peter Ko Date: July 31, 2017 Title: Design of an Aperture Assembly for X-Ray Diffraction Student: Christina Schmidt Mentor: Dr. Peter Ko Abstract: Dr. Ko and I designed and built a new X-Ray diffraction aperture

More information

Physics Requirements for the CXI 0.1 micron Sample Chamber

Physics Requirements for the CXI 0.1 micron Sample Chamber PHYSICS REQUIREMENT DOCUMENT (PRD) Doc. No. SP-391-000-20 R1 LUSI SUB-SYSTEM Coherent X-Ray Imaging Physics Requirements for the Sébastien Boutet CXI Scientist, Author Signature Date Paul Montanez CXI

More information

Air Bearing Monochromator at APS 13-ID-E (GSECARS)

Air Bearing Monochromator at APS 13-ID-E (GSECARS) Air Bearing Monochromator at APS 13-ID-E (GSECARS) Matt Newville, Peter Eng, Mark Rivers, GSECARS, U Chicago Paul Murray, IDT Upgraded Canted Beamline at GSECARS Air-bearing monochromator Performance and

More information

Introduction of New Products

Introduction of New Products Field Emission Electron Microscope JEM-3100F For evaluation of materials in the fields of nanoscience and nanomaterials science, TEM is required to provide resolution and analytical capabilities that can

More information

Acceptance test for the linear motion actuator for the scanning slit of the HIE ISOLDE short diagnostic boxes

Acceptance test for the linear motion actuator for the scanning slit of the HIE ISOLDE short diagnostic boxes EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN ACC NOTE 2014 0099 HIE ISOLDE PROJECT Note 0036 Acceptance test for the linear motion actuator for the scanning slit of the HIE ISOLDE short diagnostic boxes

More information

RANDY W. ALKIRE, GEROLD ROSENBAUM AND GWYNDAF EVANS

RANDY W. ALKIRE, GEROLD ROSENBAUM AND GWYNDAF EVANS S-94,316 PATENTS-US-A96698 BEAM POSITION MONITOR RANDY W. ALKIRE, GEROLD ROSENBAUM AND GWYNDAF EVANS CONTRACTUAL ORIGIN OF THE INVENTION The United States Government has rights in this invention pursuant

More information

Breakout Session 3: Mirror Update. 2007/4/ /22 Peter M. Stefan LCLS Facility Advisory Committee (FAC) Meeting

Breakout Session 3: Mirror Update. 2007/4/ /22 Peter M. Stefan LCLS Facility Advisory Committee (FAC) Meeting Breakout Session 3: Mirror Update 2007/4/16-17 1/22 Peter M. Stefan LCLS Facility Advisory Committee (FAC) Meeting stefan@slac.stanford.edu Breakout Session 3: Mirror Update Overall Offset Mirror System

More information

Roman Pots. Marco Oriunno SLAC, PPA. M.Oriunno, SLAC

Roman Pots. Marco Oriunno SLAC, PPA. M.Oriunno, SLAC Roman Pots Marco Oriunno SLAC, PPA The Roman Pot technique 1. The Roman Pot, an historically successful technique for near beam physics: ISR, SPS, TEVATRON, RICH, DESY 2. A CERN in-house technology: ISR,

More information

Light Guide Overview

Light Guide Overview Light Guide Overview 2 Fiber-Optic Basics Light guides are an important component in optimizing an optical system as they connect the various functional units such as the light source to a probe or a probe

More information

The SIRAD irradiation facility at the INFN - Legnaro National Laboratory

The SIRAD irradiation facility at the INFN - Legnaro National Laboratory The SIRAD irradiation facility at the INFN - Legnaro National Laboratory I. Introduction 2 The INFN - Legnaro National Laboratory (LNL) SIRAD beamline http://www.lnl.infn.it 3 What is SIRAD? SIRAD is the

More information

Operation of a Single Pass, Bunch-by-bunch x-ray Beam Size Monitor for the CESR Test Accelerator Research Program. October 3, 2012

Operation of a Single Pass, Bunch-by-bunch x-ray Beam Size Monitor for the CESR Test Accelerator Research Program. October 3, 2012 Operation of a Single Pass, Bunch-by-bunch x-ray Beam Size Monitor for the CESR Test Accelerator Research Program October 3, 2012 Goals Goals For This Presentation: 1.Provide an overview of the efforts

More information

Micro Precision Apertures

Micro Precision Apertures National Aperture, Inc. Micro Precision Apertures Product Guide Precision apertures, targets and patterns, including round, slit, square, etc., for universal and high power applications National Aperture,

More information

Specification of the varied-line-spacing plane grating. monochromator for the TPS port-24 beamline at NSRRC

Specification of the varied-line-spacing plane grating. monochromator for the TPS port-24 beamline at NSRRC Specification of the varied-line-spacing plane grating monochromator for the TPS port-24 beamline at NSRRC July, 2014 Copyright 2014 National Synchrotron Radiation Research Center (NSRRC). This document

More information

RESOLUTE UHV absolute optical encoder

RESOLUTE UHV absolute optical encoder L-9517-9530-01-L RESOLUTE UHV absolute optical encoder Clean RGA Low outgassing rate Bake-out temperature of 120 C True absolute non-contact optical encoder system: no batteries required Wide set-up tolerances

More information

CATALOG Welcome to the world of SmarAct.

CATALOG Welcome to the world of SmarAct. CATALOG 2017 Welcome to the world of SmarAct www.smaract.com TABLE OF CONTENTS INTRODUCTION... 3 LINEAR POSITIONERS...20 ROTARY POSITIONERS...54 GONIOMETERS...72 MICRO-GRIPPERS...82 OPTO-MECHANICS...92

More information

LEOK-3 Optics Experiment kit

LEOK-3 Optics Experiment kit LEOK-3 Optics Experiment kit Physical optics, geometrical optics and fourier optics Covering 26 experiments Comprehensive documents Include experiment setups, principles and procedures Cost effective solution

More information

PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry

PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry Purpose PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry In this experiment, you will study the principles and applications of interferometry. Equipment and components PASCO

More information

Week IV: FIRST EXPERIMENTS WITH THE ADVANCED OPTICS SET

Week IV: FIRST EXPERIMENTS WITH THE ADVANCED OPTICS SET Week IV: FIRST EXPERIMENTS WITH THE ADVANCED OPTICS SET The Advanced Optics set consists of (A) Incandescent Lamp (B) Laser (C) Optical Bench (with magnetic surface and metric scale) (D) Component Carriers

More information

LUSI Pulse Picker System

LUSI Pulse Picker System ENGINEERING SPECIFICATION DOCUMENT (ESD) Doc. No. SP-391-001-50 R0 LUSI SUB-SYSTEM DCO LUSI Pulse Picker System Rick Jackson Design Engineer, Author Signature Date Marc Campell DCO Design Engineer Signature

More information

Shenglan Xu. GM/CA CAT Argonne National Laboratory

Shenglan Xu. GM/CA CAT Argonne National Laboratory MECHANICAL DESIGN OF NEW DUAL PINHOLE MINI- BEAM COLLIMATOR WITH MOTORIZED PITCH AND YAW ADJUSTER PROVIDES LOWER BACKGROUND FOR X-RAY CRYSTALLOGRAPHY AT GMCA@APS Shenglan Xu GM/CA CAT Argonne National

More information

Precise hardening with high power diode lasers using beam shaping mirror optics

Precise hardening with high power diode lasers using beam shaping mirror optics Precise hardening with high power diode lasers using beam shaping mirror optics Steffen Bonss, Marko Seifert, Berndt Brenner, Eckhard Beyer Fraunhofer IWS, Winterbergstrasse 28, D-01277 Dresden, Germany

More information

First Observation of Stimulated Coherent Transition Radiation

First Observation of Stimulated Coherent Transition Radiation SLAC 95 6913 June 1995 First Observation of Stimulated Coherent Transition Radiation Hung-chi Lihn, Pamela Kung, Chitrlada Settakorn, and Helmut Wiedemann Applied Physics Department and Stanford Linear

More information

ESCALAB 250: High Performance Imaging XPS

ESCALAB 250: High Performance Imaging XPS Application Note: 31063 ESCALAB 250: High Performance Imaging XPS Key Words Surface Analysis High Resolution High Sensitivity Multitechnique Parallel Imaging Introduction The Thermo Scientific ESCALAB

More information

LOS 1 LASER OPTICS SET

LOS 1 LASER OPTICS SET LOS 1 LASER OPTICS SET Contents 1 Introduction 3 2 Light interference 5 2.1 Light interference on a thin glass plate 6 2.2 Michelson s interferometer 7 3 Light diffraction 13 3.1 Light diffraction on a

More information

This lecture contains four sections as reading information.

This lecture contains four sections as reading information. Sample Preparation: The Backloading Technique This lecture contains four sections as reading information. Basic XRD Course 1 Sample Preparation: The Backloading Technique Basic XRD Course 2 Sample Preparation:

More information

Nano Beam Position Monitor

Nano Beam Position Monitor Introduction Transparent X-ray beam monitoring and imaging is a new enabling technology that will become the gold standard tool for beam characterisation at synchrotron radiation facilities. It allows

More information

hurryscan, hurryscan II

hurryscan, hurryscan II hurryscan, hurryscan II more Information at: universal and compatible These compact scan heads from SCANLAB provide optimal solutions for nearly all challenges found in industrial laser materials processing.

More information

Sources & Beam Line Optics

Sources & Beam Line Optics SSRL Scattering Workshop May 16, 2006 Sources & Beam Line Optics Thomas Rabedeau SSRL Beam Line Development Objective/Scope Objective - develop a better understanding of the capabilities and limitations

More information

Mechanical Design of an Ultra-High-Vacuum Compatible Compact Hard X-ray Monochromator with Artificial Channel-Cut Crystal Mechanism

Mechanical Design of an Ultra-High-Vacuum Compatible Compact Hard X-ray Monochromator with Artificial Channel-Cut Crystal Mechanism Mechanical Design of an Ultra-High-Vacuum Compatible Compact Hard X-ray Monochromator with Artificial Channel-Cut Crystal Mechanism D. Shu, S. Narayanan, and Alec Sandy Experimental Facilities Division,

More information

PRISMAPRO. The latest generation of compact mass spectrometers. Modular design. Powerful software. Low detection limit.

PRISMAPRO. The latest generation of compact mass spectrometers. Modular design. Powerful software. Low detection limit. The latest generation of compact mass spectrometers. Modular design. Powerful software. Low detection limit. The latest generation of compact mass spectrometers. The combination of high sensi tivity, maximum

More information

Frequency Tuning and RF Systems for the ATLAS Energy Upgrade. Gary P. Zinkann

Frequency Tuning and RF Systems for the ATLAS Energy Upgrade. Gary P. Zinkann Frequency Tuning and RF Systems for the ATLAS Energy Upgrade Outline Overview of the ATLAS Energy Upgrade Description of cavity Tuning method used during cavity construction Description and test results

More information

Microtools Shaped by Focused Ion Beam Milling and the Fabrication of Cylindrical Coils

Microtools Shaped by Focused Ion Beam Milling and the Fabrication of Cylindrical Coils Microtools Shaped by Focused Ion Beam Milling and the Fabrication of Cylindrical Coils M.J. Vasile, D.P. Adams #, and Y.N. Picard* Sandia National Laboratories P.O. Box 5800, MS 0959 Albuquerque, NM, 87185

More information

A COMPACT, 1-MV, 6-kA RADIOGRAPHY SOURCE WITH A ONE- METER EXTENSION AND RIGHT-ANGLE BEND

A COMPACT, 1-MV, 6-kA RADIOGRAPHY SOURCE WITH A ONE- METER EXTENSION AND RIGHT-ANGLE BEND A COMPACT, 1-MV, 6-kA RADIOGRAPHY SOURCE WITH A ONE- METER EXTENSION AND RIGHT-ANGLE BEND B. M. Huhman ξ a, R. J. Allen, G. Cooperstein, D. Mosher b, J.W. Schumer, F.C. Young b Plasma Physics Division,

More information

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26 Today s Outline - January 25, 2018 C. Segre (IIT) PHYS 570 - Spring 2018 January 25, 2018 1 / 26 Today s Outline - January 25, 2018 HW #2 C. Segre (IIT) PHYS 570 - Spring 2018 January 25, 2018 1 / 26 Today

More information

Product Range Electronic Units

Product Range Electronic Units Pyramid Technical Consultants, Inc. 1050 Waltham Street Suite 200 Lexington, MA 02421 TEL: +1 781 402-1700 TEL (UK): +44 1273 492001 FAX: (781) 402-1750 EMAIL: SUPPORT@PTCUSA.COM Product Range Electronic

More information

High Energy Digital Radiography & 3D-CT for Industrial Systems

High Energy Digital Radiography & 3D-CT for Industrial Systems DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography, June 25-27, 2007, Lyon, France High Energy Digital Radiography & 3D-CT for Industrial Systems Non-Destructive

More information

membrane sample EUV characterization

membrane sample EUV characterization membrane sample EUV characterization Christian Laubis, PTB Outline PTB's synchrotron radiation lab Scatter from structures Scatter from random rough surfaces Measurement geometries SAXS Lifetime testing

More information

Supplementary Figure 1

Supplementary Figure 1 Supplementary Figure 1 Technical overview drawing of the Roadrunner goniometer. The goniometer consists of three main components: an inline sample-viewing microscope, a high-precision scanning unit for

More information

Scanning electron microscope

Scanning electron microscope Scanning electron microscope 6 th CEMM workshop Maja Koblar, Sc. Eng. Physics Outline The basic principle? What is an electron? Parts of the SEM Electron gun Electromagnetic lenses Apertures Chamber and

More information

1064nm High Power Fiber Collimator

1064nm High Power Fiber Collimator 1064 High Power Fiber Collimator High Handing Power Low Insertion High Return Loss Fiber Optics Components Center avelength Operating avelength Range Nominal Beam Diamter mm orking Distance mm Typ. Insertion

More information

Laser Telemetric System (Metrology)

Laser Telemetric System (Metrology) Laser Telemetric System (Metrology) Laser telemetric system is a non-contact gauge that measures with a collimated laser beam (Refer Fig. 10.26). It measure at the rate of 150 scans per second. It basically

More information

Supplementary Information

Supplementary Information Supplementary Information Supplementary Figure 1. Modal simulation and frequency response of a high- frequency (75- khz) MEMS. a, Modal frequency of the device was simulated using Coventorware and shows

More information

Development of a Vibration Measurement Method for Cryocoolers

Development of a Vibration Measurement Method for Cryocoolers REVTEX 3.1 Released September 2 Development of a Vibration Measurement Method for Cryocoolers Takayuki Tomaru, Toshikazu Suzuki, Tomiyoshi Haruyama, Takakazu Shintomi, Akira Yamamoto High Energy Accelerator

More information

Nmark AGV-HP. High Accuracy, Thermally Stable Galvo Scanner

Nmark AGV-HP. High Accuracy, Thermally Stable Galvo Scanner Nmark AGV-HP Galvanometer Nmark AGV-HP High Accuracy, Thermally Stable Galvo Scanner Highest accuracy scanner available attains single-digit, micron-level accuracy over the field of view Optical feedback

More information

ADALAM Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing D2.2. Ger Folkersma (Demcon)

ADALAM Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing D2.2. Ger Folkersma (Demcon) D2.2 Automatic adjustable reference path system Document Coordinator: Contributors: Dissemination: Keywords: Ger Folkersma (Demcon) Ger Folkersma, Kevin Voss, Marvin Klein (Demcon) Public Reference path,

More information

Agilent 10774A Short Range Straightness Optics and Agilent 10775A Long Range Straightness Optics

Agilent 10774A Short Range Straightness Optics and Agilent 10775A Long Range Straightness Optics 7Y Agilent 10774A Short Range Straightness Optics and Agilent 10775A Long Range Straightness Optics Introduction Introduction Straightness measures displacement perpendicular to the axis of intended motion

More information

On-line spectrometer for FEL radiation at

On-line spectrometer for FEL radiation at On-line spectrometer for FEL radiation at FERMI@ELETTRA Fabio Frassetto 1, Luca Poletto 1, Daniele Cocco 2, Marco Zangrando 3 1 CNR/INFM Laboratory for Ultraviolet and X-Ray Optical Research & Department

More information

Week IX: INTERFEROMETER EXPERIMENTS

Week IX: INTERFEROMETER EXPERIMENTS Week IX: INTERFEROMETER EXPERIMENTS Notes on Adjusting the Michelson Interference Caution: Do not touch the mirrors or beam splitters they are front surface and difficult to clean without damaging them.

More information

9 th International Workshop on Personal Computers and Particle Accelerator Controls, VECC, Kolkata, India

9 th International Workshop on Personal Computers and Particle Accelerator Controls, VECC, Kolkata, India Master slave topology based, remotely operated, precision X-ray beam profiler and placement system for high pressure physics experiment at Indus-2 beam line 9 th International Workshop on Personal Computers

More information

Introduction to X-ray Detectors for Synchrotron Radiation Applications

Introduction to X-ray Detectors for Synchrotron Radiation Applications Introduction to X-ray Detectors for Synchrotron Radiation Applications Pablo Fajardo Instrumentation Services and Development Division ESRF, Grenoble EIROforum School on Instrumentation (ESI 2011) Outline

More information

The Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, Kraków, Poland.

The Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, Kraków, Poland. The Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, 31-342 Kraków, Poland. www.ifj.edu.pl/reports/2003.html Kraków, grudzień 2003 Report No 1931/PH

More information

Diamond X-ray Rocking Curve and Topograph Measurements at CHESS

Diamond X-ray Rocking Curve and Topograph Measurements at CHESS Diamond X-ray Rocking Curve and Topograph Measurements at CHESS G. Yang 1, R.T. Jones 2, F. Klein 3 1 Department of Physics and Astronomy, University of Glasgow, Glasgow, UK G12 8QQ. 2 University of Connecticut

More information

no mm no Dividers with scriber 150 mm NEW Square wedge-shaped knife edges on the length side

no mm no Dividers with scriber 150 mm NEW Square wedge-shaped knife edges on the length side Summer Promotion valid until 30.06.2013 all quoted prices are incl. VAT for deliveries to EU countries to customers with valid VAT-no. and for deliveries in non EU member countries the VAT is not applicable

More information

The CoSAXS Beamline at MAX IV: A Small Angle X-Ray Scattering Beamline to Study Structure and Dynamics

The CoSAXS Beamline at MAX IV: A Small Angle X-Ray Scattering Beamline to Study Structure and Dynamics The CoSAXS Beamline at MAX IV: A Small Angle X-Ray Scattering Beamline to Study Structure and Dynamics SAS Sample Environment workshop, September 10-11 th, 2015- Lund tomas.plivelic@maxlab.lu.se Aims Take

More information

x-ray Beam Size Monitor

x-ray Beam Size Monitor x-ray Beam Size Monitor J. Alexander, N. Eggert, J. Flanagan, W. Hopkins, B. Kreis, M. McDonald, D. Peterson, N. Rider Goals: 2 products: tuning tool with rapid feedback of beam height during LET measurements

More information

NON-TRADITIONAL MACHINING PROCESSES ULTRASONIC, ELECTRO-DISCHARGE MACHINING (EDM), ELECTRO-CHEMICAL MACHINING (ECM)

NON-TRADITIONAL MACHINING PROCESSES ULTRASONIC, ELECTRO-DISCHARGE MACHINING (EDM), ELECTRO-CHEMICAL MACHINING (ECM) NON-TRADITIONAL MACHINING PROCESSES ULTRASONIC, ELECTRO-DISCHARGE MACHINING (EDM), ELECTRO-CHEMICAL MACHINING (ECM) A machining process is called non-traditional if its material removal mechanism is basically

More information

Small Angle Scattering Platform for Structural Biology

Small Angle Scattering Platform for Structural Biology Small Angle Scattering Platform for Structural Biology Petra Pernot, ESRF OUTLINE: SAXS/SANS in Grenoble: new SAS platform of CISB Conversion of ID14-EH3 from MX to bio-saxs MAXINF2 Integration Workshop

More information

OPERATION OF A SINGLE PASS, BUNCH-BY-BUNCH X-RAY BEAM SIZE MONITOR FOR THE CESR TEST ACCELERATOR RESEARCH PROGRAM*

OPERATION OF A SINGLE PASS, BUNCH-BY-BUNCH X-RAY BEAM SIZE MONITOR FOR THE CESR TEST ACCELERATOR RESEARCH PROGRAM* OPERATION OF A SINGLE PASS, BUNCH-BY-BUNCH X-RAY BEAM SIZE MONITOR FOR THE CESR TEST ACCELERATOR RESEARCH PROGRAM* N.T. Rider, M. G. Billing, M.P. Ehrlichman, D.P. Peterson, D. Rubin, J.P. Shanks, K. G.

More information

intelliweld smart welding

intelliweld smart welding intellield more Information at: smart welding Designed for robot-assisted welding applications, this 3D-scan system is capable of swiftly positioning the laser beam along 3D contours. hile a robot guides

More information

OPTICS IN MOTION. Introduction: Competing Technologies: 1 of 6 3/18/2012 6:27 PM.

OPTICS IN MOTION. Introduction: Competing Technologies:  1 of 6 3/18/2012 6:27 PM. 1 of 6 3/18/2012 6:27 PM OPTICS IN MOTION STANDARD AND CUSTOM FAST STEERING MIRRORS Home Products Contact Tutorial Navigate Our Site 1) Laser Beam Stabilization to design and build a custom 3.5 x 5 inch,

More information

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G APPLICATION NOTE M01 attocfm I for Surface Quality Inspection Confocal microscopes work by scanning a tiny light spot on a sample and by measuring the scattered light in the illuminated volume. First,

More information

CESRTA Low Emittance Tuning Instrumentation: x-ray Beam Size Monitor

CESRTA Low Emittance Tuning Instrumentation: x-ray Beam Size Monitor CESRTA Low Emittance Tuning Instrumentation: x-ray Beam Size Monitor xbsm group: (those who sit in the tunnel) J. Alexander, N. Eggert, J. Flanagan, W. Hopkins, B. Kreis, M. McDonald, D. Peterson, N. Rider

More information

Our Company. We are major supplier to:

Our Company. We are major supplier to: VACUUM METROLOGY Our Company Hositrad Holland and Hositrad Deutschland combine more than 50 years of experience in vacuum and cryogenic technology. Customers profit from a broad range of capabilities,

More information

The New ID11 Nanoscope end-station A Nano-Tomography Scanner

The New ID11 Nanoscope end-station A Nano-Tomography Scanner The New ID11 Nanoscope end-station A Nano-Tomography Scanner A focus on the sample positioning stages I. ID11 Beamline II. III. IV. Design architecture A rotation stage with nanometer-level performance

More information

HIQUAD. New high-end mass spectrometer! Fast, flexible and easy to operate.

HIQUAD. New high-end mass spectrometer! Fast, flexible and easy to operate. New high-end mass spectrometer! Fast, flexible and easy to operate. New high-end mass spectrometer! Fast, flexible and easy to operate. A modular solution for mass spectrometry With the new HiQuad mass

More information

High Rep-Rate KrF Laser Development and Intense Pulse Interaction Experiments for IFE*

High Rep-Rate KrF Laser Development and Intense Pulse Interaction Experiments for IFE* High Rep-Rate KrF Laser Development and Intense Pulse Interaction Experiments for IFE* Y. Owadano, E. Takahashi, I. Okuda, I. Matsushima, Y. Matsumoto, S. Kato, E. Miura and H.Yashiro 1), K. Kuwahara 2)

More information

SECOND HARMONIC GENERATION AND Q-SWITCHING

SECOND HARMONIC GENERATION AND Q-SWITCHING SECOND HARMONIC GENERATION AND Q-SWITCHING INTRODUCTION In this experiment, the following learning subjects will be worked out: 1) Characteristics of a semiconductor diode laser. 2) Optical pumping on

More information

Rotary Encoder System Compact Model Range

Rotary Encoder System Compact Model Range we set the standards RIK Rotary Encoder System Compact Model Range 2 Incremental rotary encoder Features Compact design, consisting of scanning head with round cable, 15pin D-sub connector and grating

More information

Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore Tel: Fax:

Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore Tel: Fax: Sintec Optronics Technology Pte Ltd 10 Bukit Batok Crescent #07-02 The Spire Singapore 658079 Tel: +65 63167112 Fax: +65 63167113 High-power Nd:YAG Self-floating Laser Cutting Head We supply the laser

More information

A DUAL-PORTED PROBE FOR PLANAR NEAR-FIELD MEASUREMENTS

A DUAL-PORTED PROBE FOR PLANAR NEAR-FIELD MEASUREMENTS A DUAL-PORTED PROBE FOR PLANAR NEAR-FIELD MEASUREMENTS W. Keith Dishman, Doren W. Hess, and A. Renee Koster ABSTRACT A dual-linearly polarized probe developed for use in planar near-field antenna measurements

More information

3 General layout of the XFEL Facility

3 General layout of the XFEL Facility 3 General layout of the XFEL Facility 3.1 Introduction The present chapter provides an overview of the whole European X-Ray Free-Electron Laser (XFEL) Facility layout, enumerating its main components and

More information

Precision Micro-Aperture Catalog

Precision Micro-Aperture Catalog National Aperture, Inc. Precision Micro-Aperture Catalog Version 2012 PLEASE CONTACT: Data Optics, Inc. Distributor for National Aperture, Inc. Phone: (734) 483-8228 (800) 321-9026 Fax: (734) 483-9879

More information

System configurations. Main features. I TScan SOLUTION FOR

System configurations. Main features. I TScan SOLUTION FOR TScan TScan is a fast and ultra-accurate planar near-field scanner with the latest motor drive and encoder technologies. High acceleration of the linear motors for stepped and continuous mode operation

More information

VUV-FEL User workshop, August 23-24, 2004

VUV-FEL User workshop, August 23-24, 2004 Layout of the user facility Kai Tiedtke Kai Tiedtke, HASYLAB@ VUV-FEL User workshop, August 23-24, 2004 Kai.Tiedtke@desy.de Kai Tiedtke, HASYLAB@ Outline Photon beam transport Layout of the experimental

More information

Kit for building your own THz Time-Domain Spectrometer

Kit for building your own THz Time-Domain Spectrometer Kit for building your own THz Time-Domain Spectrometer 16/06/2016 1 Table of contents 0. Parts for the THz Kit... 3 1. Delay line... 4 2. Pulse generator and lock-in detector... 5 3. THz antennas... 6

More information

Development of C-Mod FIR Polarimeter*

Development of C-Mod FIR Polarimeter* Development of C-Mod FIR Polarimeter* P.XU, J.H.IRBY, J.BOSCO, A.KANOJIA, R.LECCACORVI, E.MARMAR, P.MICHAEL, R.MURRAY, R.VIEIRA, S.WOLFE (MIT) D.L.BROWER, W.X.DING (UCLA) D.K.MANSFIELD (PPPL) *Supported

More information

DESIGN OF COMPACT PULSED 4 MIRROR LASER WIRE SYSTEM FOR QUICK MEASUREMENT OF ELECTRON BEAM PROFILE

DESIGN OF COMPACT PULSED 4 MIRROR LASER WIRE SYSTEM FOR QUICK MEASUREMENT OF ELECTRON BEAM PROFILE 1 DESIGN OF COMPACT PULSED 4 MIRROR LASER WIRE SYSTEM FOR QUICK MEASUREMENT OF ELECTRON BEAM PROFILE PRESENTED BY- ARPIT RAWANKAR THE GRADUATE UNIVERSITY FOR ADVANCED STUDIES, HAYAMA 2 INDEX 1. Concept

More information

Single Slit Diffraction

Single Slit Diffraction PC1142 Physics II Single Slit Diffraction 1 Objectives Investigate the single-slit diffraction pattern produced by monochromatic laser light. Determine the wavelength of the laser light from measurements

More information

Usage and Setup From Actuators to Controls

Usage and Setup From Actuators to Controls NanoDiff@P11 Usage and Setup From Actuators to Controls Jan Meyer 9th mxcube Developer's Meeting ESRF, 16.01.2017 Outline > Construction To Controllers Source - Beamline P11 Goniometer and Accessories

More information

k λ NA Resolution of optical systems depends on the wavelength visible light λ = 500 nm Extreme ultra-violet and soft x-ray light λ = 1-50 nm

k λ NA Resolution of optical systems depends on the wavelength visible light λ = 500 nm Extreme ultra-violet and soft x-ray light λ = 1-50 nm Resolution of optical systems depends on the wavelength visible light λ = 500 nm Spatial Resolution = k λ NA EUV and SXR microscopy can potentially resolve full-field images with 10-100x smaller features

More information

Corundum C Axis Device for Sample Preparation Timothy Thomas, M.E., M.S.E.E. GIA Laboratory June 4, 2009

Corundum C Axis Device for Sample Preparation Timothy Thomas, M.E., M.S.E.E. GIA Laboratory June 4, 2009 Abstract Corundum C Axis Device for Sample Preparation Timothy Thomas, M.E., M.S.E.E. GIA Laboratory June 4, 2009 As a part of GIA s on going project to establish a comprehensive corundum database a need

More information

X-ray Transport Optics and Diagnostics Commissioning Report

X-ray Transport Optics and Diagnostics Commissioning Report LCLS-TN-4-15 UCRL-PROC-27494 X-ray Transport Optics and Diagnostics Commissioning Report Richard M. Bionta, Lawrence Livermore National Laboratory. October 23, 24 LCLS Diagnostics and Commissioning Workshop,

More information

-_.-~ Sample. HIGH SENSITIVITY TYPE TOTAL REFLECTION X-RAY SPECTROMETER SYSTEM Wafer Surface Analysis System --

-_.-~ Sample. HIGH SENSITIVITY TYPE TOTAL REFLECTION X-RAY SPECTROMETER SYSTEM Wafer Surface Analysis System -- THE RIGAKU JOURNAL VOl. 8 / NO. 1 / 1991 HIGH SENSITIVITY TYPE TOTAL REFLECTION X-RAY SPECTROMETER SYSTEM 3726 --Wafer Surface Analysis System -- 1. Introduction System 3726 utilizes the total reflection

More information

Activity P35: Light Intensity in Double-Slit and Single-Slit Diffraction Patterns (Light Sensor, Rotary Motion Sensor)

Activity P35: Light Intensity in Double-Slit and Single-Slit Diffraction Patterns (Light Sensor, Rotary Motion Sensor) Name Class Date Activity P35: Light Intensity in Double-Slit and Single-Slit Diffraction Patterns (Light Sensor, Rotary Motion Sensor) Concept DataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win) Interference

More information

PicoMaster 100. Unprecedented finesse in creating 3D micro structures. UV direct laser writer for maskless lithography

PicoMaster 100. Unprecedented finesse in creating 3D micro structures. UV direct laser writer for maskless lithography UV direct laser writer for maskless lithography Unprecedented finesse in creating 3D micro structures Highest resolution in the market utilizing a 405 nm diode laser Structures as small as 300 nm 375 nm

More information

ANALYTICAL MICRO X-RAY FLUORESCENCE SPECTROMETER

ANALYTICAL MICRO X-RAY FLUORESCENCE SPECTROMETER Copyright(c)JCPDS-International Centre for Diffraction Data 2001,Advances in X-ray Analysis,Vol.44 325 ANALYTICAL MICRO X-RAY FLUORESCENCE SPECTROMETER ABSTRACT William Chang, Jonathan Kerner, and Edward

More information

Be aware that there is no universal notation for the various quantities.

Be aware that there is no universal notation for the various quantities. Fourier Optics v2.4 Ray tracing is limited in its ability to describe optics because it ignores the wave properties of light. Diffraction is needed to explain image spatial resolution and contrast and

More information

Mirrors. Plano and Spherical. Mirrors. Published on II-VI Infrared

Mirrors. Plano and Spherical. Mirrors. Published on II-VI Infrared Page 1 of 13 Published on II-VI Infrared Plano and Spherical or total reflectors are used in laser cavities as rear reflectors and fold mirrors, and externally as beam benders in beam delivery systems.

More information

Experiment 10. Diffraction and interference of light

Experiment 10. Diffraction and interference of light Experiment 10. Diffraction and interference of light 1. Purpose Perform single slit and Young s double slit experiment by using Laser and computer interface in order to understand diffraction and interference

More information

Spectroscopy Lab 2. Reading Your text books. Look under spectra, spectrometer, diffraction.

Spectroscopy Lab 2. Reading Your text books. Look under spectra, spectrometer, diffraction. 1 Spectroscopy Lab 2 Reading Your text books. Look under spectra, spectrometer, diffraction. Consult Sargent Welch Spectrum Charts on wall of lab. Note that only the most prominent wavelengths are displayed

More information

7. Michelson Interferometer

7. Michelson Interferometer 7. Michelson Interferometer In this lab we are going to observe the interference patterns produced by two spherical waves as well as by two plane waves. We will study the operation of a Michelson interferometer,

More information

Q-Motion Miniature Linear Stage

Q-Motion Miniature Linear Stage Q-Motion Miniature Stage Smallest linear stage with position control, high resolution and affordable price Q-521 Only 21 mm wide and 10 mm high Direct position measurement with integrated incremental,

More information