HYDROPHILIC ACRYLIC ADVANCED POLYMER
|
|
- Sherman Green
- 6 years ago
- Views:
Transcription
1 PRODUCT CATALOGUE
2 i-medical GmbH founded in Heidelberg Germany brings quality products to the world of ophthalmic surgery. With many years experience in this medical speciality, we at i-medical are well qualified to service the ophthalmic surgeon s need world-wide. Our mission is to continue to offer top quality products at affordable prices therefore satisfying the ever growing need for cost-effective ophthalmic surgery. To learn more about our products contact your i-medical team. UV-ABSORBING HYDROPHOBIC ACRYLIC Injection molded OVERVIEW AS natural - Natural tint DESIGN/ OPTIC OPTIC/LENS SIZE (mm) HAPTIC ANGULATION A-CONSTANT (Estimated) REF. INDEX ACD (mm) DIOPTERS (Dpt.) AVAILABLE Bi-aspheric 6.0 x to 0.0 Dpt. in 1.0 Increments 1.5 to 27.5 Dpt. Bio-Stable lens - Due to superior manufacturing process resulted this lens is Bio-Stable and vacuoles free (no pearl effect) TIT-Tackiness Inhibiting Technology - It ensures per reproducibility lens after lens (injection molded) - TIT used on anterior surface to ensure perfect unfolding tacky surface ensure perfect adhesion between capsular bag and posterior surface of the lens and reduces the incidence of PCO - Unfolding time is less than 5 sec INJECTOR/ CARTRIDGE BioLine YELLOW BLUELIGHT FILTER AND UV-ABSORBING HYDROPHILIC ACRYLIC ADVANCED POLYMER BioLine YELLOW BLUELIGHT DESIGN/ OPTIC OPTIC/LENS SIZE (mm) HAPTIC ANGULATION A-CONSTANT (Estimated) REF. INDEX ACD (mm) DIOPTERS (Dpt.) AVAILABLE 6.0 x to 0.0 Dpt. INJECTOR/ CARTRIDGE BioLine YELLOW ACCURATE ASPHERIC Aspherical 6.0 x to 4.0 Dpt.
3 UV-ABSORBING HYDROPHILIC ACRYLIC ADVANCED POLYMER i-flex i-flex AS - Ready to use - Self Centering DESIGN/ OPTIC Aspherical OPTIC/LENS SIZE (mm) 6.0 x x 12.0 HAPTIC ANGULATION 0 0 A-CONSTANT (Estimated) REF. INDEX ACD (mm) DIOPTERS (Dpt.) AVAILABLE -7.0 to 40.0 Dpt to 0.0 Dpt. INJECTOR/ CARTRIDGE 6025 C - Ready to use 6.0 x to 0.0 Dpt. AS 6025 C - Ready to use Aspherical 6.0 x to 0.0 Dpt. 651 C - Ready to use 6.5 x to 0.0 Dpt C - Plate with Stable Capsular Compression (SCC) 6.0 x to 0.0 Dpt C - Plate with Stable Capsular Compression (SCC) - Diabetic Lens 7.0 x to 40.0 Dpt. i-soft - Plate with Stable Capsular Compression (SCC) - Diabetic Lens 5.75 x to 0.0 Dpt.
4 UV-ABSORBING SINGLE PIECE 100% PMMA DESIGN/ OPTIC OPTIC/LENS SIZE (mm) HAPTIC ANGULATION A-CONSTANT (Estimated) DIOPTERS (Dpt.) AVAILABLE DIAMETER BEFORE/AFTER COMPRESSION (mm) 5525 PM 5.5 x to.0 Dpt PM 6.0 x to.0 Dpt PM 6.0 x to 1.0 Dpt. 600 PM 6.0 x to 2.0 Dpt. 650 PM 6.5 x to 0.0 Dpt. AC 6025 PM - Anterior 6.0 x to 0.0 Dpt. CTR - Capsular Tension Ring - For the stabilisation of the capsular bag Before After
5 Microsurgical Knife ITEM NO. WIDTH DESCRIPTION ITEM NO. WIDTH DESCRIPTION Stab I Full Handle I Full Handle I Full Handle Crescent I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Straight, full handle I Full Handle I mm Angled, blade and tip, bevel up I / mm Full Handle, restricted depth blade I mm Straight, blade and tip I / 5 mm Full Handle, restricted depth blade I mm Angled, full handle, bevel up Clear Corneal Clear Corneal -Side Cutting/ Parallel Sides I / mm Blade and tip, restricted depth blade I / 5 mm Blade and tip, restricted depth blade I Blade and tip I Blade and tip I / 4 mm Full Handle, restricted depth blade I /.5 mm Full Handle, restricted depth blade I mm Angled, full handle, double bevel I mm Angled, full handle, double bevel I mm Angled, full handle, double bevel I mm Angled, full handle, double bevel I mm Angled, full handle, double bevel I mm Angled, full handle, double bevel I mm Angled, full handle, double bevel I mm Angled, full handle, double bevel I mm Angled, full handle, double bevel I mm Angled, full handle, double bevel I mm Angled, full handle, double bevel Trapezoid Implant Myringotomy Blades I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I º, downward cut, offset I º, upward cut, offset I Spear Tip, narrow shaft, offset I Lance Tip, narrow shaft, offset Phaco Slit I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up Vitrectomy I gauge Straight, full handle I gauge Straight, full handle I gauge Angled, full handle I gauge Straight, full handle I gauge Angled, full handle I gauge Straight, full handle I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Straight, full handle, single bevel I mm Straight, full handle, single bevel I mm Angled, blade and tip, bevel up I mm Angled, blade and tip, bevel up I mm Angled, blade and tip, bevel up I mm Angled, blade and tip, bevel up I mm Angled, full handle, double bevel I mm Angled, full handle, double bevel Sideport - MVR Design Specialty I mm Angled, full handle I mm Angled, full handle I mm Angled, full handle I mm Angled, full handle I Scleral, straight, blade only I Round Tip, straight, blade only I Lamellar, angled, blade only I Mini, straight, blade only I Needle blade, straight, full handle I All Around, straight, blade only MicroPhaco Slit I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up Bevel Design bevel down bevel up double bevel I mm Angled, full handle, bevel up I mm Angled, full handle, bevel up I mm Angled, full handle, double bevel Disc/Spoon I mm Angled, full handle, double bevel I mm Angled, full handle, double bevel
6 STORAGE MOLECULAR WEIGHT VISCOSITY PH-VALUE OSMOLALITY CANNULA i-visc 1.0 SODIUM HYALURONATE - Sterile, endotoxin free cohesive viscoelastic solution from sodium hyaluronate of biofermentative origin - suitable for a large number of Surgical proceedings of the eye. Between 2 and 25 C Do not freeze mill. Dalton mpas mosm/kg 27 g i-visc 1.0 with 1.0% sodium hyaluronate, filled in syringes at 1 ml sterile. i-visc 1.4 SODIUM HYALURONATE - Sterile, endotoxin free cohesive viscoelastic solution from sodium hyaluronate of biofermentative origin - suitable for a large number of Surgical proceedings of the eye. Between 2 and 25 C Do not freeze mill. Dalton mpas mosm/kg 27 g i-visc 1.4 with 1.4% sodium hyaluronate, filled in syringes at 1 ml sterile. i-visc 1.6 SODIUM HYALURONATE - Sterile, endotoxin free cohesive viscoelastic solution from sodium hyaluronate of biofermentative origin - suitable for a large number of Surgical proceedings of the eye. Between 2 and 25 C Do not freeze mill. Dalton mpas mosm/kg 27 g i-visc 1.6 with 1.6% sodium hyaluronate, filled in syringes at 1 ml sterile. i-visc 2.0 HYDROXYPROPYLMETHYL- CELLULOSUM - Sterile, endotoxin free viscoelastic solution from hydroxipropylmethylcellulosum (HPMC) -reseasonable alternative to other hyaluronic acid products - for trouble free cataract surgery and IOL implantation - improved sight during surgical procedure of the eye in precorneal application - ideal viscoelastic properties when implanting foldable IOLs by means of injectors. Between 2 and 25 C Do not freeze Dalton mpas mosm/kg 2 g Sterile disposable syringe at 2 ml of 2% Hydroxypropylmethylcellulosum, single application.
7 INSTRUCTION i-glide - i-glide small 1.85 mm incision size 2.2 mm - i-glide medium 2.2 mm incision size 2.85 mm - Single use cartridges, sterile - For lens implantation - Open cartridge and inject visco ensuring no bubbles get entrapped in the cartridge lumen. - Place lens into cartridge ensuring that the whole lens is seated in the grove created by the open wings of the cartridge. - Shut the wings while taking care that no part of the lens gets trapped between the wings. Visually confirm this. i-ject - Disposable - Titanium - Injector - For lens implantation - Remove injector from the pouch and visually inspect the same. Ensure smooth movement of the plunger. - Align the back of the cartridge with the injector mouth and press in firmly. - Once the cartridge locks in place, visually check if the silicon tip of the plunger is aligned with the aurifies of the cartridge. A port has been provided to visualise this. - Press the plunger in one smooth slow motion till the lens is inside the lumen. Check during this time that no excessive force is required as this may be an indication of the lens having been trapped between the wings or the plunger tip has overridden the lens. If this is the case, do not proceed further. Check loading process again. Now enter the eye and press the plunger till the lens comes out fully and disengages from the cartridge. INSTRUCTION i-glide Tube - incision size 2.8 mm - Single use cartridges, sterile - For lens implantation - Open cartridge and inject visco ensuring no bubbles get entrapped in the cartridge lumen. - Place lens into cartridge ensuring that the whole lens is seated. i-ject II - Lightweight titanium handle with single plunger mechanism - Injector - For lens implantation - Remove injector from the pouch and visually inspect the same. Ensure smooth movement of the plunger. - Align the back of the cartridge with the injector mouth and press in firmly. - Once the cartridge locks in place. - Press the plunger in one smooth slow motion till the lens is inside the lumen. Check during this time that no excessive force is required as this may be an indication of the lens having been trapped. If this is the case, do not proceed further. Check loading process again. Now enter the eye and press the plunger till the lens comes out fully and disengages from the cartridge.
8 i-medical Ophthalmic International GmbH Wieblinger Weg Heidelberg/Germany Tel.: +49(0) Fax: +49(0) All products in this brochure are 0481 marked. Information as of 08/2012 i-medical als Wort-Bildmarke ist ein registriertes Markenzeichen in Europa: HABM / Alicante, Registernummer: Weltweit registriert: WIPO / Genf, Madrider-Abkommen: Registernummer: Markenrechtsinhaberin: i-medical Ophthalmic International GmbH, Heidelberg / Deutschland. i-visc als Wort-Bildmarke ist ein registriertes Markenzeichen in Deutschland: DPMA / München: Registernummer: Markenrechtsinhaberin: i-medical Ophthalmic International GmbH, Heidelberg / Deutschland. i-medical Ophthalmic International (Pty) Ltd. Postnet Suite 41 Private Bag x 4 Wierda Park 0149 South Africa Tel: Fax: info@imedicalsa.co.za
Unique Aberration-Free IOL: A Vision that Patients
Unique Aberration-Free IOL: A Vision that Patients Can Appreciate An Aspheric Optic for Improved Quality of Vision n Traditional spherical IOLs create Bilateral implantation study spherical aberration
More informationCONTENTS. HYDROPHILIC IOLs. Bi-Flex PIL-MA hydrophilic preloaded P / PY 677PT / PTY 677PMY 677PMTY. Bi-Flex HL...
Bi-Flex IOL RANGE CONTENTS HYDROPHILIC IOLs Bi-Flex PIL-MA hydrophilic preloaded... 1 677P / PY 677PT / PTY 677PMY 677PMTY Bi-Flex HL... 2 677AB / ABY Bi-Flex T... 3 677TA / TB 677TAY / TBY Bi-Flex M...
More informationNot everyone can do this. Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision
Not everyone can do this Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision RayOne fully preloaded IOL injection system, designed to deliver without
More informationGlistening-Free Hydrophobic Acrylic IOL. Glistening-Free Hydrophobic Acrylic IOL
Glistening-Free Hydrophobic Acrylic IOL Proprietary Polymer Composition Packaged Dry UD Aspheric Optic Optimized Refractive Index All SquareTM Enhanced Edge Largest Diopter Range -05.00D to 42.00D Modified
More informationday night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT
day supreme contrast sensitivity night convinced THE IOL FOR DAY & NIGHT The IOL for DAY & NIGhT UnIQUE form and features Innovative blue light filtering Excellent quality of vision Maximum depth of focus
More informationEXPAND YOUR VIEW. SUSTAIN YOUR ACCESS. OASIS IRIS EXPANDER DESIGNED FOR SAFETY & EFFICIENCY. PREMIER EDGE SAFETY SCALPELS SAFETY CRESCENT SCALPEL
EXPAND YOUR VIEW. SUSTAIN YOUR ACCESS. OASIS IRIS EXPANDER PATENT NO. 8,439,833 B2 A polypropylene ring that gently expands the iris due to insufficiently dilated pupils and sustains visibility throughout
More informationI N M A D E F R A N C E. Hydrophobic monofocal NEW QUALITY SAFETY STABILITY TECHNICAL BROCHURE
ENGINEERED AND M A D E I N F R A N C E Hydrophobic monofocal NEW QUALITY SAFETY STABILITY TECHNICAL BROCHURE Genesis, is a new hydrophobic intraocular lens developed and manufactured by CUTTING EDGE to
More informationLong-term quality of vision is what every patient expects
Long-term quality of vision is what every patient expects Innovative combination of HOYA technologies provides: 1-piece aspheric lens with Vivinex hydrophobic acrylic material Unique surface treatment
More informationRayOne Hydrophobic IOL. New design. New standard MADE IN UK
RayOne Hydrophobic IOL New design. New standard MADE IN UK Setting new standards since 1949 About Rayner When Sir Harold Ridley designed the world s first IOL in 1949, he chose Rayner to manufacture this
More informationPRODUCT CATALOGUE Sterile Single Use Instruments for Cataract and Vitreoretinal Surgery
PRODUCT CATALOGUE Sterile Single Use Instruments for Cataract and Vitreoretinal Surgery CONTENTS CONTENTS CONTENTS INTRODUCTION Page Single Use Instruments 4 5 Per Procedure Trays 7 CATARACT SURGERY Specula
More informationAT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients
Premium Trifocal MICS OVDs IOLs AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients The moment you help your patients
More informationIntraocular lens Difficulties
Intraocular lens Difficulties Sameh Fouda MD, FRCS Assistant Professor Of Ophthalmology Faculty Of Medicine, Zagazig University IOL in history Sir Harold Ridley, in the 1940s,discovered that shards of
More informationSulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric
Sulcoflex Pseudophakic Sulcus Fixated Secondary IOLs Sulcoflex Aspheric Sulcoflex Toric Sulcoflex Multifocal For when perfection is the only option! Sulcoflex Pseudophakic Sulcus Fixated Secondary IOLs
More informationROTATIONAL STABILITY MAKES THE DIFFERENCE
The Bi-Flex platform the proven platform of Excellence 01 Proven Stability less than 02 Optimal biomaterials 2 degrees long term rotation 03 Posterior Toric Lens surface with marks indicating the flat
More informationFEA of Prosthetic Lens Insertion During Cataract Surgery
Visit the SIMULIA Resource Center for more customer examples. FEA of Prosthetic Lens Insertion During Cataract Surgery R. Stupplebeen, C. Liu, X. Qin Bausch + Lomb, SIMULIA, SIMULIA Abstract: Cataract
More informationPRODUCT CATALOGUE Sterile Single Use Instruments for Cataract and Vitreoretinal Surgery
PRODUCT CATALOGUE Sterile Single Use Instruments for Cataract and Vitreoretinal Surgery Safety. Consistency. Convenience. CONTENTS CONTENTS CONTENTS INTRODUCTION Page Single Use Instruments 4 5 Per Procedure
More informationIOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university
IOL Types Hazem Elbedewy M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university Artificial intraocular lenses are used to replace the eye natural lens when it has been removed during cataract surgery.
More informationNEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients
Premium Trifocal MICS OVDs IOLs NEW AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients Trifocal toric IOL The moment
More informationProduct Portfolio. Sulcoflex Pseudophakic Supplementary IOLs
Product Portfolio Sulcoflex Pseudophakic Supplementary IOLs Sulcoflex Pseudophakic Supplementary IOLs For when compromise is not an option As a cataract and refractive surgeon, achieving the best possible
More informationMEDICAL/SURGICAL CUTTING INSTRUMENTS
1-800-263-3557 The Cutting Edge of Tomorrow For Ophthalmic Products click on the logo below: MEDICAL/SURGICAL CUTTING INSTRUMENTS INTRODUCTION Surgistar, Inc. has been manufacturing high quality microsurgical
More informationLaser Glasses
Laser Glasses 2 Laser Glasess is a disposable product. It has %99 UV protection It is desinged to protect eye from light, wind or any external impacts Com24 hours continuous use due to its flexibility.
More informationH.P. BRAEM AG. Ophthaltech Switzerland. Precision is our passion
H.P. BRAEM AG Ophthaltech Switzerland Precision is our passion PRODUCT CATALOG 2017 2 This brochure gives you an introduction in the present product range of H.P. BRAEM AG. Please be aware that products
More informationNew CONNECTING VISIONS
Surgical Products New CONNECTING VISIONS Connecting Visions Topcon and Oculentis - Partners in Intraocular Surgery Oculentis as a company stands for innovativeness, closeness to the customer and flexibility.
More informationTHE ASPHERIC PRELOADED INJECTION
New from STAAR for Safe and Easy Implantation THE ASPHERIC PRELOADED INJECTION S Y S T E M PRELOADED INJECTION SYSTEM FOR SIMPLE AND EASY IOL DELIVERY SAFE The KS3-Ai features an aspheric IOL preloaded
More informationSEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses
SEE BEYOND WITH FULLRANGE OPTICS Developed by Hanita Lenses SEE beyond with FullRange optics FullRange optic lenses are proven, highlyreliable and safe intraocular lenses designed to provide a solution
More informationProduct Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision.
Product Portfolio Sulcoflex Pseudophakic Supplementary IOLs Your skill. Our vision. Sulcoflex Pseudophakic Supplementary IOLs For when compromise is not an option As a cataract and refractive surgeon,
More informationMaximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision
Multifocal Maximum Light Transmission Pupil-independent Light Distribution Better Visual Quality Increased Contrast Sensitivity 3.75D Near Addition Improved Intermediate Vision Visual Performance After
More informationPROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE
PROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE PROGRESSIVE VISION Progressive vision within full accomodative range 03 Suitable for sub 2 mm MICS 01 PAD Progressive- Apodized-Diffractive 02 Aspheric
More informationPreloaded. PreciSAL. EZ Toric
Preloaded PreciSAL EZ Toric Experience the beauty with new vision Make a difference every time 1 Why you should choose MBI 3 Our vision is clear 4 PreciSAL quality 5 MTF of PreciSAL 7 Optical precision
More informationCOMPARISON OF THE MEDICONTUR 860FAB
COMPARISON OF THE MEDICONTUR 860FAB HYDROPHOBIC IOL AND THE ACRYSOF IQ LONG TERM FOLLOW UP Péter Vámosi MD, Amanda Argay MD, Zsófia Rupnik MD, János Fekete Péterfy Sándor Hospital Budapest, Hungary PREFERENCE
More informationClinical Evaluation 3-month Follow-up Report
Clinical Evaluation 3-month Follow-up Report Of SeeLens HP Intraocular Lens 27 December 2010 version 1.1 1of 16 Table of Contents TABLE OF CONTENTS... 1 OBJECTIVES... 2 EFFICACY AND SAFETY ASSESSMENTS...
More informationThe complete choice in refractive lens solutions
The complete choice in refractive lens solutions The VeriFlex phakic IOL is part of Advanced Medical Optics range of high-contrast, high-quality refractive lens solutions. In addition to excellent training
More informationPreciSAL Preloaded Lens System
ns PreciSAL Preloaded Lens System SAL P302A, SAL P302AC SAL PT302A, SAL PT302AC CAUTION: Federal (USA) law restricts this medical device to the sale by or on the order of a physician. DEVICE DESCRIPTION
More information(12) United States Patent (10) Patent No.: US 7,156,854 B2
US007 156854B2 (12) United States Patent (10) Patent No.: US 7,156,854 B2 BrOWn et al. (45) Date of Patent: Jan. 2, 2007 (54) LENS DELIVERY SYSTEM 5,944,725 A * 8/1999 Cicenas et al.... 606/107 6,241,737
More informationEXCHANGE. Financial Disclosure. Clinical pearls In advanced anterior segment surgery being able to do a IOL exchange is a must. Why Do an Exchange
Financial Disclosure D. Ayres, MD Cornea Service IOLBrandon Wills Eye Hospital EXCHANGE Alcon Allergan AMO Bausch and Lomb TearScience BioTissue Why Do an Exchange Refractive surprise after cataract surgery
More informationContents. Corneal Markers, Scleral Depressors
Corneal Markers, Scleral Depressors Contents Ring Markers... 4-1 LASIK Markers... 4-2 LRI/Astigmatism Markers... 4-3 Miscellaneous Markers... 4-4 Scleral Depressors... 4-5 4-B www.storzeye.com 800-338-2020
More informationImproving Lifestyle Vision. with Small Aperture Optics
Improving Lifestyle Vision with Small Aperture Optics The Small Aperture Premium Lens Solution The IC-8 small aperture intraocular lens (IOL) is a revolutionary lens that extends depth of focus by combining
More informationThe Percutaneous Reduction Forceps Technique Guide
The Percutaneous Reduction Forceps Technique Guide Indications + Product Overview Introduction The Percutaneous Reduction Forceps The Percutaneous Reduction Forceps facilitate standard technique for fixation
More information*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most
Simulated vision. Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most The aspheric design of the AcrySof IQ IOL results in improved clarity and image quality. The
More informationUIN: IOL Date of Prep: April Avansee Preload1P. Technical Slide Kit April 2017
Avansee Preload1P Technical Slide Kit April 2017 Agenda 1. Avansee Preload1P: Summary of product characteristics 2. Excellent IOL characteristics 2.1 Glistening-free optic 2.2 360 degree square edge 2.3
More informationEvolution of Diffractive Multifocal Intraocular Lenses
Evolution of Diffractive Multifocal Intraocular Lenses Wavefront Congress February 24, 2007 Michael J. Simpson, Ph.D. Alcon Research, Ltd., Fort Worth, Texas Presentation Overview Multifocal IOLs two lens
More informationThe OPUS AutoCuff System for Rotator Cuff Repair
The OPUS AutoCuff System for Rotator Cuff Repair A revolutionary new system specifically designed for rotator cuff repair surgery System Includes: SmartStitch Suturing Device The Magnum PI Implant with
More informationVItREOREtINAL single-use INstRUMENts.
the BENCHMARK FOR VItREOREtINAL single-use INstRUMENts. Unmatched GeUder precision in 20, 23 and 25 GaUGe. 20G 23G 25G C O L O R L I N E 20G 23G 25G UNO COLORLINE 2 C O L O R L I N E SINGLE-USE INSTRUMENTS
More informationAnterior Cervical Plate SURGICAL TECHNIQUE GUIDE. Surgeon Driven Innovation
Anterior Cervical Plate SURGICAL TECHNIQUE GUIDE Surgeon Driven Innovation 1 The Snowmass Anterior Cervical Plate System is intended for the surgical treatment and correction of traumatic and pathologic
More informationifs 150 khz IntraLase Technology
How to create a perfect LASIK flap with Intralase Dr Lim Li, FRCS Head(Clinical & Education) Senior Consultant Corneal and External Eye Disease Service Singapore National Eye Centre Financial Interest:
More informationWORLD S LEADING CATARACT TECHNOLOGY FOR SMALL INCISION. Small Incision Small Incision to serve surgeon s cataract technique
Newsletter Fall 014 NEWSTM WORLD S LEADING CATARACT TECHNOLOGY FOR SMALL INCISION ASICO is world recognized for Technological Innovations in Ophthalmic Surgery. Working side by side with Innovative surgeons
More informationInterlagos Retractor System Surgical Technique
Interlagos Retractor System Surgical Technique TABLE OF CONTENTS Instructions for Use Design Rationale Surgical Technique 1. Pre-Operative Preparation 2. Pedicle Preparation 3. Primary Retraction 4. Secondary
More informationDr. Magda Rau Eye Clinic Cham, Germany
3 and 6 Months clinical Results after Implantation of OptiVis Diffractive-refractive Multifocal IOL Dr. Magda Rau Eye Clinic Cham, Germany Refractive zone of Progressive power for Far to Intermediate
More informationThe design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1
The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1 The clear choice for consistent visual excellence. For over 165 years Bausch
More informationGETTING STARTED WITH DMEK
ORBIS WEBINAR MARCH 2018 GETTING STARTED WITH DMEK JAMES LEHMANN, MD SAN ANTONIO, TX GETTING STARTED WITH DMEK DISCLOSURES JAMES LEHMANN, MD Private Practice, Focal Point Vision Associate Instructor, University
More informationVITREORETINAL 20G 23G 25G. Unmatched Geuder precision in 20, 23 and 25 gauge.
the benchmark for VITREORETINAL single-use instruments. Unmatched Geuder precision in 20, 23 and 25 gauge. 20G 23G 25G C O L O R L I N E 20G 23G 25G Uno Colorline 2 C O L O R L I N E SINGLE-USE INSTRUMENTS
More information7 DO IT. A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE
A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE 7 DO IT. TRIFOCAL PERFORMANCE & GLASS INDEPENDENCY UNCOMPROMISED CONTRAST
More informationSutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique
Published online: July 21, 2015 1663 2699/15/0062 0239$39.50/0 This is an Open Access article licensed under the terms of the Creative Commons Attribution-NonCommercial 3.0 Unported license (CC BY-NC)
More information(12) United States Patent (10) Patent No.: US 6,334,862 B1
USOO6334862B1 (12) United States Patent (10) Patent No.: Vidal et al. (45) Date of Patent: *Jan. 1, 2002 (54) APPARATUS AND METHODS FOR IOL 4,785,810 A 11/1988 Buccala et al. INSERTON 4,836,201. A 6/1989
More informationClinical Evaluation 3-month Follow-up Report
Clinical Evaluation 3-month Follow-up Report Of SeeLens AF Intraocular Lens 30 June 2010 version 1.1 1 of 21 Table of Contents: Objectives 2 Medical device specification and administration 4 Methods 9
More informationSurgical Technique Guide
Surgical Technique Guide Patented - www.flow-fx.net Flow-FX, LLC 9301 W 191st Street Mokena, IL 60448 P. 815.531.4424 by Flow-FX, LLC. 2017 Products referenced with TM are trademarks of Flow-Fx. STG-101
More informationTHE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.
XtraFocus THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES. CONTENT Based on the well-established principle of pinhole optics, this intraocular implant represents an innovative alternative for the
More informationSUPERSEDED. NOT the LATEST REVISION
Figure 1 OPTIMATE 2.5mm bayonet ceramic connector kits listed in Figure 1 are designed to be applied to fiber optic cable. Coupling Receptacle Kit 501381 1 is used to mate two bayonet connectors in free
More informationTechnique Guide. 2.4/2.7 mm Locking Tarsal Plates. Talus Plate, Navicular Plate and Cuboid Plate.
Technique Guide 2.4/2.7 mm Locking Tarsal Plates. Talus Plate, Navicular Plate and Cuboid Plate. Table of Contents Introduction 2.4/2.7 mm Locking Tarsal Plates 2 AO Principles 4 Indications 5 Clinical
More informationReflex Hybrid System Overview
Spine Reflex Hybrid System Overview Anterior Cervical Plating System Introduction The Reflex Hybrid ACP System offers a low-profile anterior cervical plate along with a selection of bone screw types to
More informationNewsletter Spring 2015
NEWSTM WORLD S LEADING CATARACT TECHNOLOGY FOR SMALL INCISION 015 SPRING VISION NEWS Vol. I Page : Micro Incision Cataract Innovations Page : Femtosecond Cataract Toric Marking Simplified Technology Page
More informationTechnicians & Nurses Program
ASCRS ASOA Symposium & Congress Technicians & Nurses Program May 6-10, 2016 New Orleans ADVANCED BIOMETRY AND IOL CALCULATIONS Financial Disclosures No relevant disclosures Karen Bachman, COMT, ROUB The
More informationTHE NEXT BIG THING IN SCLERAL HAPTIC FIXATION
THE NEXT BIG THING IN SCLERAL HAPTIC FIXATION The double-needle technique bypasses the surgical gymnastics required by other strategies. BY D. BRIAN KIM, MD CATARACT SURGERY IOL implantation in the absence
More informationErgonomically Evolving Range
Irrigation & Aspirationat the leading edge Ergonomically Evolving Range Find us on Bi-Manual Handpieces Aspiration Handpieces Instruments coloured blue to signify aspiration Aspiration arrow shows direction
More informationRumex International Co. Vitreoretinal Instruments + Consumables
Rumex International Co. Vitreoretinal Instruments + Consumables Rumex International Company 13770 58th Street North, Suite 317 Clearwater, FL 33760, USA shop@rumex.net Universal Handles for Vitreoretinal
More informationTechnique Guide. 7.0 mm Cannulated Screws. Part of the Synthes Cannulated Screw System.
Technique Guide 7.0 mm Cannulated Screws. Part of the Synthes Cannulated Screw System. Table of Contents Introduction 7.0 mm Cannulated Screws 2 AO Principles 3 Indications 4 Surgical Technique Surgical
More informationMatrixMANDIBLE Preformed Reconstruction Plates. Preshaped to the mandibular anatomy.
MatrixMANDIBLE Preformed Reconstruction Plates. Preshaped to the mandibular anatomy. Technique Guide CMF Matrix Table of Contents Introduction MatrixMANDIBLE Preformed Reconstruction Plates 2 AO Principles
More informationSLEEVE AND PITCH INSTRUCTION BOOKLET
SLEEVE AND PITCH INSTRUCTION BOOKLET Contents Section I: Replacing White, Green or Black Sleeves with Low Wear 12cm Green Sleeves Refer to this section if your oars currently have original white, green
More informationMEDICAL ADVANCED TECHNOLOGY EMERGENCY REMOVAL UNIVERSAL EXTRACTION SET. for Intramedullary Nail System
MEDICAL ADVANCED TECHNOLOGY EMERGENCY REMOVAL UNIVERSAL EXTRACTION SET for Intramedullary Nail System introducing ourselve Manufacturer of surgical implants and medical devices. Solutions for patient orthopaedic
More informationTitle: Live volumetric (4D) visualization and guidance of in vivo human ophthalmic surgery with intraoperative optical coherence tomography
Title: Live volumetric (4D) visualization and guidance of in vivo human ophthalmic surgery with intraoperative optical coherence tomography Authors: O. M. Carrasco-Zevallos 1, B. Keller 1, C. Viehland
More informationVECTRA SURGICAL TECHNIQUE. Anterior cervical plate system. This publication is not intended for distribution in the USA.
VECTRA Anterior cervical plate system This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE Image intensifier control This description alone does not provide sufficient background
More informationChoosing the Proper Power for the IOL. Brannon Aden, MD Miles H. Friedlander, MD, FACS
Choosing the Proper Power for the IOL Brannon Aden, MD Miles H. Friedlander, MD, FACS Goal s of Surgery Have Changed. In past the goal was good visual outcome Now an equal goal is a good refractive outcome
More informationth St N Suite 113 Largo, FL (888) (888) Fax
11733 66th St N Suite 113 Largo, FL 33773 (888) 548-4462 (888) 548-1462 Fax www.i-ma.com C A TA L O G ACCU-DISC TM Fluid Dispensing Syringe The ACCU-DISC TM Pressure Monitoring System offers the advantage
More informationCentre Hospitalier Universitaire et Psychiatrique de Mons-Borinage. B-Flex Multifocal. Dr Emmanuel Van Acker Belgium
Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage B-Flex Multifocal Dr Emmanuel Van Acker Belgium Comparison of clinical outcomes and patient satisfaction after implantation of two different
More informationSpecial Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)
Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language) LENTIS Mplus - The one -and and-only Non--rotationally Symmetric Multifocal Lens Multi-center
More informationedge of the section wound, probably from opening of the wound
CORNEO-SCLERAL SUTURE IN CATARACT EXTRACTION 269 A CORNEO-SCLERAL SUTURE IN CATARACT EXTRACTION. ITS TECHNIQUE AND ADVANTAGES BY H. B. STALLARD LONDON THE use of a corneo-scleral suture in the operation
More informationURS Degen. Top loading pedicle screw system for posterior stabilization.
URS Degen. Top loading pedicle screw system for posterior stabilization. Technique Guide This publication is not intended for distribution in the USA. Table of Contents Introduction URS Degen 2 AO Principles
More informationEvolution of the Cataract Patient
Evolution of the Cataract Patient Mark Maraman O.D., M.S. Pacific Cataract and Laser Institute Disclosures I have no financial relationships or conflicts of interest with the manufacturers of any commercial
More informationTHE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening
THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening Clinical Applications Corneal Implant Planning The comes with a licensable corneal inlay software module
More information3.5 mm Cannulated Screw Technique Guide
3.5 mm Cannulated Screw Technique Guide An Integral Part of the SYNTHES Cannulated Screw System Original Instruments and Implants of the Association for the Study of Internal Fixation AO ASIF The 3.5 mm
More informationVECTRA. SURGICAL TECHNIQUE. Anterior cervical plate system. This publication is not intended for distribution in the USA.
VECTRA. Anterior cervical plate system. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE Contents Indications and contraindications Implants Vario Case Instruments Surgical
More informationOPERATIVE TECHNIQUE RIVAL REDUCE FRACTURE PLATING SYSTEM. foot & ankle trauma procedures
OPERATIVE TECHNIQUE RIVAL REDUCE FRACTURE PLATING SYSTEM foot & ankle trauma procedures INTRODUCTION 3 SYSTEM DESCRIPTION 3 TECHNICAL DETAILS 4 SALES AND MARKETING CONFIGURATION 5 OPERATIVE TECHNIQUE 7
More informationAxis Mounting System Instructions
M Panadent Corporation 580 S. Rancho Avenue Colton, California 92324, USA Tel: (909) 783-1841 USA & Canada (800) 368-9777 These instructions apply to the following items: h2250 2251 Axis Mounting System
More informationMultifocal and Accommodative
What is an IOL? An intraocular lens (or IOL) is a tiny, artificial lens for the eye. It replaces the eye's natural lens. Retina Cornea Lens Macula The eye's normally clear lens bends (refracts) light rays
More information2 Reusable Titanium. Single Piece Specula. Page 4-6
Duckworth & Kent titanium surgical instrument manufacturer at the leading edge Specula Opening the eyes of the world Closed Blades Open Blades Solid Blades Find us on Single Piece Specula Page 4-6 Made
More informationNOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.
NOW Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers Accommodating. Aberration Free. Aspheric. Accommodation Meets Asphericity in AO Merging Innovation & Proven Design The
More informationBionic Fistula Needles. The gentle puncture
Bionic Fistula Needles The gentle puncture Oozing at the puncture site leads to an increased risk of infection for patients and staff. The Bionic needle design prevents these side-effects by its cylindrical
More informationOCULUS Pentacam AXL Always an Axial Length Ahead
OCULUS Pentacam AXL Always an Axial Length Ahead EFFICIENCY AND BETTER WORKFLOW Your Cataract Workstation! The new Pentacam AXL is an alliance of the time-tested Pentacam technology with high-precision
More informationTechnique Guide. Occipito-Cervical Fusion System. Implants and instruments designed to optimize fixation to the occiput.
Technique Guide Occipito-Cervical Fusion System. Implants and instruments designed to optimize fixation to the occiput. Table of Contents Introduction Overview 2 AO ASIF Principles 4 Indications and Contraindications
More informationWhat s a Corneal GP Lens?
Slide 1 What s a Corneal GP Lens? Richard Dorer NCLEC Blanchard Contact Lens Inc. 800-367-4009 x 131 richarddorer@gmail.com www.blanchardlab.com Slide 2 Endorsements I am a paid representative and consultant
More informationEDOF-IOLs: Are they all the same?
Gerd.Auffarth@med.uni-heidelberg.de www.ivcrc.com www.djapplelab.com EDOF-IOLs: Are they all the same? G. U. Auffarth International Vision Correction Research Centre (IVCRC), The David J. Apple International
More informationSmall Plate and Screw System SURGICAL TECHNIQUE
MINI MAXLOCK EXTREME Small Plate and Screw System SURGICAL TECHNIQUE Contents Key Design Features 2 Surgical Technique 3 Implants and Instruments 9 Proper surgical procedures and techniques are the responsibility
More informationVariAx Foot Locking Plate System
VariAx Foot Locking Plate System Operative Technique Trauma and Deformity Correction Polyaxial Locking Technology Comprehensive Calcaneal Fracture Plates Table of Contents 1. Introduction 3 2. Overview
More informationTechnique Guide. 4.5 mm Cannulated Screws. Part of the Synthes Cannulated Screw System.
Technique Guide 4.5 mm Cannulated Screws. Part of the Synthes Cannulated Screw System. TableofContents Introduction 4.5 mm Cannulated Screws 2 AO Principles 3 Indications 4 Surgical Technique Surgical
More informationGlenco Gas/Liquid Syringes from Spectrum Chromatography
Glenco Gas/Liquid Syringes from Spectrum Chromatography D10122 180296 Copyright 1996 by Spectrum Chromatography PO Box 672026 Houston, TX 77267-2026 Phone: (281) 443-2900 (800) 459-9700 (US & Canada) Fax:
More informationVariAx DistalFibula. Foot & Ankle. Locking Plate System. Operative Technique
VariAx DistalFibula Locking Plate System Operative Technique Foot & Ankle Distal Fibula Fracture Repair Polyaxial Locking Technology Low Profile Design VariAx 2 Color Coded Screws and Instruments VariAx
More informationThe solution ensures the concise translation of all indications into digital data no scanning spray or powder required.
Page 1 of 5 Identium Scan Light 1. Introduction The future of the world is in digital processes including that of the dental world. What will this mean for the traditional discipline of making impressions?
More informationArthroscopic Protector Meniscus Suturing Surgical Techniques
Arthroscopic Protector Meniscus Suturing Surgical Techniques Protector Meniscus Suturing Protector Meniscus Suturing Technique I For the relatively rare meniscus tears located sufficiently anterior, to
More informationOPHTHALMIC SURGICAL MODELS
OPHTHALMIC SURGICAL MODELS BIONIKO designs innovative surgical models, task trainers and teaching tools for the ophthalmic industry. Our surgical models present the user with dexterity and coordination
More informationModified Peripheral Iris Fixation of a Foldable Intraocular Lens Following Phacoemulsification
C A S E R E P O R T Modified Peripheral Iris Fixation of a Foldable Intraocular Lens Following Phacoemulsification Jia-Kang Wang, Pei-Ching Lai* In this report, we describe the case of an aphakic patient
More information