SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses

Size: px
Start display at page:

Download "SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses"

Transcription

1 SEE BEYOND WITH FULLRANGE OPTICS Developed by Hanita Lenses

2 SEE beyond with FullRange optics FullRange optic lenses are proven, highlyreliable and safe intraocular lenses designed to provide a solution for presbyopia while reducing known complications associated with most diffractive lenses. These easy-to-implant, multifocal intraocular lenses provide your patients with excellent depth of focus for the near, intermediate and far visual ranges and with minimal risk of complications and the need for future touch-ups or laser corrections. SAFE Predictable results Reduced side effects EFFICIENT Maintains contrast sensitivity Reduced YAG & touch-ups Reduced stray light EFFECTIVE Crisp and sharp vision Full-range vision

3 Advanced Optical Design FullRange optic lenses were designed by worldleading diffractive optics designers using the most advanced algorithms to utilize the Apodized Aspheric-Diffractive profile of the FullRange optic, which has been clinically proven to provide clear and functional vision for all distances. Height [Microns] FullRange diffractive profile Hanita Lenses DHF optics development MF lenses Radius [mm] Apodized Diffractive Surface The state-of-the-art apodized diffractive surface provides visual functionality throughout the day in photopic, mesoptic and scotopic conditions. Light intensity [%] Apodization Near Far Hanita Lenses DHF optics development MF lenses Pupil Diameter [mm] Accurate Polish-Free Production Process FullRange optics are manufactured using a proprietary lathe process that results in maximum accuracy of the lens profile and the diffractive rings of the lens to be as sharp as possible and an identical replica of the optimal profile design generated by the Arizona eye model and leading to maximal contrast sensitivity.

4 Full-Range Functional Vision LogMAR Defocus SEELENS MF The FullRange optics lens offers a unique optic design that provides functional vision of above 0.2 LogMAR from 40 centimeters to infinity allowing your patients to function in all ranges. Diopters References Lapid-Gortzak R.; ESCRS 2016 Lowest Straylight Straylight research conducted using the FullRange lens shows that its straylight is the lowest tested in the industry. This is due to the clarity of the lens, lack of glistening and the low refractive index of the lens material. Straylight [log(s)] Age [year] ReSTOR SA60D310 ReSTOR SA6AD315 Tecnis ZM90012 ReSTOR SN6AD116 ReZoom10 SeeLens17 ReSTOR SA60D38 ReSTOR SA60D315 ReSTOR SN6AD117 ReSTOR SN6AD114 Mplus LS AT Lisa 809M17 ReSTOR SA60D311 Tecnis ZM90013 ReSTOR SN6AD19 ReZoom13 Mplus LS AT Lisa 809M15 References Grzegorz Labuz; J Cataract Refract Surg 2016; 42: Q 2016 ASCRS and ESCRS Comparison of ocular straylight after implantation of multifocal intraocular lenses; and Lapid-Gortzak R.; Refract Surg. 2015;31(11): ] Straylight Measurements in Two Different Apodized Diffractive Multifocal Intraocular Lenses Sharpest Square Edge FullRange lenses offer the sharpest square edge in the industry 72% sharper than the sharpest edge previously known in the industry. It also has additional features that promote PCO reduction include a wide angle of contact with the capsular bag and a 360-degree sharp square edge. References Tetz M.; ESCRS 2014 SN60AT* FullRange (MF) *Images: David AKREOS AO* spalton 2007 C-flex*

5 Reduced YAG Rate As a result of their extremely sharp square edge, FullRange lenses were found to have a very low YAG capsulotomy rate of 2.2% after 5 years. References Lapid-Gortzak R.; ASCRS 2017 Paper session; Nd:YAG capsulotomy Rates in angulated sharp edged hydrophilic IOLs Contrast Sensitivity Contrast Sensitivity FullRange group Monofocal group Due to its aspheric optical design profile, clinical results of the FullRange lens show superior contrast sensitivity leading to contrast sensitivity comparable to a monofocal IOL as presented by J.L. Alio at al. Log Contrast Sensitivity Units Photopic Scotopic Spatial Frequency (cpd) References Alio J.L.; Clinical outcomes with a new microincisional diffractive multifocal IOL Eye and Vision (2015) 2:2 DOI /s Contrast sensitivity function comparison between groups. It shows comparison of the postoperative contrast sensitivity function in both groups of patients under photopic and scotopic conditions. Technical Specification Platform SeeLens MF - Ø 13mm BunnyLens MF - Ø 11mm Geometry Optic Diameter: 6.0 mm Haptic angulation: 5 Double square edge Material Hydrophilic acrylic with UV-blocking and violet filtering chromopore Refractive index: 1.46 (35 C) Nd-YAG Laser Compatible Optical Design Diffractive Incision Size 1.8 mm Placement Capsular bag Note: It is recommended that surgeons personalize their A-constant based on their surgical techniques and equipment, experience and post-operative results. For more information, please visit

6 Hanita Lenses THE COMPANY Established in 1981, Hanita Lenses is a worldwide trusted developer, manufacturer and marketer of ophthalmic medical devices. GLOBAL PRESENCE Hanita Lenses has an extensive distribution network throughout Europe, Asia, Latin America and Africa. SOLUTIONS With more than 30 years of experience, Hanita Lenses provides ophthalmic surgeons all over the world with advanced intraocular lens solutions for cataract surgeries, contact lenses and accessories. The company has become synonymous with high quality, reliability and service. Hanita Lenses Intraocular & Contact Lenses Kibbutz Hanita marketing@hanitalenses.com T / Hanita Lenses. The information contained herein is subject to change without notice. Hanita Lenses shall not be liable for technical or editorial errors or omissions contained herein. Tel Fax

Unique Aberration-Free IOL: A Vision that Patients

Unique Aberration-Free IOL: A Vision that Patients Unique Aberration-Free IOL: A Vision that Patients Can Appreciate An Aspheric Optic for Improved Quality of Vision n Traditional spherical IOLs create Bilateral implantation study spherical aberration

More information

Treatment of Presbyopia during Crystalline Lens Surgery A Review

Treatment of Presbyopia during Crystalline Lens Surgery A Review Treatment of Presbyopia during Crystalline Lens Surgery A Review Pierre Bouchut Bordeaux Ophthalmic surgeons should treat presbyopia during crystalline lens surgery. Thanks to the quality and advancements

More information

PROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE

PROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE PROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE PROGRESSIVE VISION Progressive vision within full accomodative range 03 Suitable for sub 2 mm MICS 01 PAD Progressive- Apodized-Diffractive 02 Aspheric

More information

Clinical Evaluation 3-month Follow-up Report

Clinical Evaluation 3-month Follow-up Report Clinical Evaluation 3-month Follow-up Report Of SeeLens HP Intraocular Lens 27 December 2010 version 1.1 1of 16 Table of Contents TABLE OF CONTENTS... 1 OBJECTIVES... 2 EFFICACY AND SAFETY ASSESSMENTS...

More information

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients Premium Trifocal MICS OVDs IOLs AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients The moment you help your patients

More information

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university IOL Types Hazem Elbedewy M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university Artificial intraocular lenses are used to replace the eye natural lens when it has been removed during cataract surgery.

More information

ROTATIONAL STABILITY MAKES THE DIFFERENCE

ROTATIONAL STABILITY MAKES THE DIFFERENCE The Bi-Flex platform the proven platform of Excellence 01 Proven Stability less than 02 Optimal biomaterials 2 degrees long term rotation 03 Posterior Toric Lens surface with marks indicating the flat

More information

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric. NOW Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers Accommodating. Aberration Free. Aspheric. Accommodation Meets Asphericity in AO Merging Innovation & Proven Design The

More information

Evolution of Diffractive Multifocal Intraocular Lenses

Evolution of Diffractive Multifocal Intraocular Lenses Evolution of Diffractive Multifocal Intraocular Lenses Wavefront Congress February 24, 2007 Michael J. Simpson, Ph.D. Alcon Research, Ltd., Fort Worth, Texas Presentation Overview Multifocal IOLs two lens

More information

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients Premium Trifocal MICS OVDs IOLs NEW AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients Trifocal toric IOL The moment

More information

7 DO IT. A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE

7 DO IT. A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE 7 DO IT. TRIFOCAL PERFORMANCE & GLASS INDEPENDENCY UNCOMPROMISED CONTRAST

More information

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision Multifocal Maximum Light Transmission Pupil-independent Light Distribution Better Visual Quality Increased Contrast Sensitivity 3.75D Near Addition Improved Intermediate Vision Visual Performance After

More information

Improving Lifestyle Vision. with Small Aperture Optics

Improving Lifestyle Vision. with Small Aperture Optics Improving Lifestyle Vision with Small Aperture Optics The Small Aperture Premium Lens Solution The IC-8 small aperture intraocular lens (IOL) is a revolutionary lens that extends depth of focus by combining

More information

Raise your expectations. Deliver theirs.

Raise your expectations. Deliver theirs. 66 EXTENDED RANGE OF VISION MONOFOCAL-LIKE DISTANCE Raise your expectations. Deliver theirs. Now you can give your patients the best of both worlds with the first and only hybrid designed monofocal-multifocal

More information

NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL

NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL ALL TRIFOCAL IOLS ARE NOT THE SAME! Seamless Vision Near Intermediate Far Light Figure 1: Comparison of MTF Values 1,2 THE WORLD S FIRST AND ONLY

More information

Roadmap to presbyopic success

Roadmap to presbyopic success Roadmap to presbyopic success Miltos O Balidis MD, PhD, FEBOphth, ICOphth Early experience with Presbyopic correction 2003 Binocular Distance-Corrected Intermediate and Near Vision Binocular Distance-Corrected

More information

Clinical Update for Presbyopic Lens Options

Clinical Update for Presbyopic Lens Options Clinical Update for Presbyopic Lens Options Gregory D. Searcy, M.D. Erdey Searcy Eye Group Columbus, Ohio The Problem = Spherical Optics Marginal Rays Spherical IOL Light Rays Paraxial Rays Spherical Aberration

More information

Dr. Magda Rau Eye Clinic Cham, Germany

Dr. Magda Rau Eye Clinic Cham, Germany 3 and 6 Months clinical Results after Implantation of OptiVis Diffractive-refractive Multifocal IOL Dr. Magda Rau Eye Clinic Cham, Germany Refractive zone of Progressive power for Far to Intermediate

More information

Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage. B-Flex Multifocal. Dr Emmanuel Van Acker Belgium

Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage. B-Flex Multifocal. Dr Emmanuel Van Acker Belgium Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage B-Flex Multifocal Dr Emmanuel Van Acker Belgium Comparison of clinical outcomes and patient satisfaction after implantation of two different

More information

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most Simulated vision. Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most The aspheric design of the AcrySof IQ IOL results in improved clarity and image quality. The

More information

day night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT

day night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT day supreme contrast sensitivity night convinced THE IOL FOR DAY & NIGHT The IOL for DAY & NIGhT UnIQUE form and features Innovative blue light filtering Excellent quality of vision Maximum depth of focus

More information

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision.

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision. Product Portfolio Sulcoflex Pseudophakic Supplementary IOLs Your skill. Our vision. Sulcoflex Pseudophakic Supplementary IOLs For when compromise is not an option As a cataract and refractive surgeon,

More information

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs Product Portfolio Sulcoflex Pseudophakic Supplementary IOLs Sulcoflex Pseudophakic Supplementary IOLs For when compromise is not an option As a cataract and refractive surgeon, achieving the best possible

More information

The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1

The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1 The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1 The clear choice for consistent visual excellence. For over 165 years Bausch

More information

PATIENT SELECTION THE RIGHT PATIENT UNDERPROMISE AND OVERDELIVER THE PERFECT SPECTACLE FREE TREATMENT. Desires Less Dependence on glasses

PATIENT SELECTION THE RIGHT PATIENT UNDERPROMISE AND OVERDELIVER THE PERFECT SPECTACLE FREE TREATMENT. Desires Less Dependence on glasses Bilateral TECNIS MF versus Customized TECNIS MF - REZOOM Achieving Spectacle Independence THE PERFECT SPECTACLE FREE TREATMENT PATIENT SELECTION 1.ARE THEY INTERESTED IN BECOMING SPECTACLE FREE? 2.ARE

More information

Clinical Evaluation 3-month Follow-up Report

Clinical Evaluation 3-month Follow-up Report Clinical Evaluation 3-month Follow-up Report Of SeeLens AF Intraocular Lens 30 June 2010 version 1.1 1 of 21 Table of Contents: Objectives 2 Medical device specification and administration 4 Methods 9

More information

Not everyone can do this. Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision

Not everyone can do this. Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision Not everyone can do this Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision RayOne fully preloaded IOL injection system, designed to deliver without

More information

Advances in the design and

Advances in the design and A look into the IOL space BY R MCNEIL Advances in the design and performance of intraocular lenses (IOLs) continue to be driven by demand for better outcomes, presbyopia correction and spectacle independence,

More information

COMPARISON OF THE MEDICONTUR 860FAB

COMPARISON OF THE MEDICONTUR 860FAB COMPARISON OF THE MEDICONTUR 860FAB HYDROPHOBIC IOL AND THE ACRYSOF IQ LONG TERM FOLLOW UP Péter Vámosi MD, Amanda Argay MD, Zsófia Rupnik MD, János Fekete Péterfy Sándor Hospital Budapest, Hungary PREFERENCE

More information

Sulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric

Sulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric Sulcoflex Pseudophakic Sulcus Fixated Secondary IOLs Sulcoflex Aspheric Sulcoflex Toric Sulcoflex Multifocal For when perfection is the only option! Sulcoflex Pseudophakic Sulcus Fixated Secondary IOLs

More information

Multifocal and Accommodative

Multifocal and Accommodative What is an IOL? An intraocular lens (or IOL) is a tiny, artificial lens for the eye. It replaces the eye's natural lens. Retina Cornea Lens Macula The eye's normally clear lens bends (refracts) light rays

More information

Multifocal IOL Basics

Multifocal IOL Basics Multifocal IOL Basics Types of Multifocal Designs REFRACTIVE Concentric zones: M-flex (Rayner) Segmented: LENTIS Mplus (Oculentis) DIFFRACTIVE Progressive: 677MY (Medicontur) Bifocal: IQ AcrySof ReSTOR

More information

CONTENTS. HYDROPHILIC IOLs. Bi-Flex PIL-MA hydrophilic preloaded P / PY 677PT / PTY 677PMY 677PMTY. Bi-Flex HL...

CONTENTS. HYDROPHILIC IOLs. Bi-Flex PIL-MA hydrophilic preloaded P / PY 677PT / PTY 677PMY 677PMTY. Bi-Flex HL... Bi-Flex IOL RANGE CONTENTS HYDROPHILIC IOLs Bi-Flex PIL-MA hydrophilic preloaded... 1 677P / PY 677PT / PTY 677PMY 677PMTY Bi-Flex HL... 2 677AB / ABY Bi-Flex T... 3 677TA / TB 677TAY / TBY Bi-Flex M...

More information

Long-term quality of vision is what every patient expects

Long-term quality of vision is what every patient expects Long-term quality of vision is what every patient expects Innovative combination of HOYA technologies provides: 1-piece aspheric lens with Vivinex hydrophobic acrylic material Unique surface treatment

More information

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12 Choices and Vision Jeffrey Koziol M.D. How does the eye work? What is myopia? What is hyperopia? What is astigmatism? What is presbyopia? How the eye works How the Eye Works 3 How the eye works Light rays

More information

Ocular Scatter. Rayleigh Scattering

Ocular Scatter. Rayleigh Scattering Ocular Scatter The are several sources of stray light in the eye including the cornea, transmission through the iris and the crystalline lens. Cornea tends to have Rayleigh Scatter Lens follows inverse

More information

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results Matteo Piovella MD & Barbara Kusa MD CMA, Centro di Microchirurgia Ambulatoriale

More information

Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects

Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects Published on Points de Vue International Review of Ophthalmic Optics () Home > Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects Multifocal Intraocular Lenses for

More information

Accommodating IOL s History and Clinical Management

Accommodating IOL s History and Clinical Management Accommodating IOL s History and Clinical Management Bausch & Lomb Surgical Aliso Viejo, CA Genesis of an Accommodating IOL 1 Observations with Plate IOLs Stuart Cumming 1989 Some plate haptic IOL patients

More information

Financial disclosure. Alcon, Zeiss, J&J AMO, Physiol, Thea, Allergan, Santen, Dompe, Cutting Edge) Race for Progress!

Financial disclosure. Alcon, Zeiss, J&J AMO, Physiol, Thea, Allergan, Santen, Dompe, Cutting Edge) Race for Progress! Financial disclosure Alcon, Zeiss, J&J AMO, Physiol, Thea, Allergan, Santen, Dompe, Cutting Edge) Race for Progress! What is new : to pay for progress? 4 properties Asphericity (Q factor) correlated to

More information

EDoF IOL. ZEISS AT LARA 829MP Next generation Extended Depth of Focus Intraocular Lens. NEW EDoF IOL from ZEISS

EDoF IOL. ZEISS AT LARA 829MP Next generation Extended Depth of Focus Intraocular Lens. NEW EDoF IOL from ZEISS EDoF IOL Next generation Extended Depth of Focus Intraocular Lens NEW EDoF IOL from ZEISS Introducing the next generation EDoF IOL with the widest range of focus.* ZEISS AT LARA The new premium lens from

More information

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN Financial Disclosure Advanced Medical Optics Allergan Bausch & Lomb PowerVision Revision Optics

More information

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language) Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language) LENTIS Mplus - The one -and and-only Non--rotationally Symmetric Multifocal Lens Multi-center

More information

WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION. Cataract treatment

WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION. Cataract treatment WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION Cataract treatment OK, I HAVE A CATARACT. NOW WHAT? WE UNDERSTAND YOUR CONCERNS WE CAN HELP.

More information

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up Antonio Mocellin, MD & Matteo Piovella, MD CMA, Centro di Microchirurgia Ambulatoriale Monza (Milan) Italy Dr Piovella

More information

The complete choice in refractive lens solutions

The complete choice in refractive lens solutions The complete choice in refractive lens solutions The VeriFlex phakic IOL is part of Advanced Medical Optics range of high-contrast, high-quality refractive lens solutions. In addition to excellent training

More information

Glistening-Free Hydrophobic Acrylic IOL. Glistening-Free Hydrophobic Acrylic IOL

Glistening-Free Hydrophobic Acrylic IOL. Glistening-Free Hydrophobic Acrylic IOL Glistening-Free Hydrophobic Acrylic IOL Proprietary Polymer Composition Packaged Dry UD Aspheric Optic Optimized Refractive Index All SquareTM Enhanced Edge Largest Diopter Range -05.00D to 42.00D Modified

More information

Preloaded. PreciSAL. EZ Toric

Preloaded. PreciSAL. EZ Toric Preloaded PreciSAL EZ Toric Experience the beauty with new vision Make a difference every time 1 Why you should choose MBI 3 Our vision is clear 4 PreciSAL quality 5 MTF of PreciSAL 7 Optical precision

More information

RayOne Hydrophobic IOL. New design. New standard MADE IN UK

RayOne Hydrophobic IOL. New design. New standard MADE IN UK RayOne Hydrophobic IOL New design. New standard MADE IN UK Setting new standards since 1949 About Rayner When Sir Harold Ridley designed the world s first IOL in 1949, he chose Rayner to manufacture this

More information

EDOF-IOLs: Are they all the same?

EDOF-IOLs: Are they all the same? Gerd.Auffarth@med.uni-heidelberg.de www.ivcrc.com www.djapplelab.com EDOF-IOLs: Are they all the same? G. U. Auffarth International Vision Correction Research Centre (IVCRC), The David J. Apple International

More information

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12 Choices and Vision Jeffrey Koziol M.D. How does the eye work? What is myopia? What is hyperopia? What is astigmatism? What is presbyopia? How the eye works Light rays enter the eye through the clear cornea,

More information

ASPIRA PUBLICATION LIST

ASPIRA PUBLICATION LIST ASPIRA PUBLICATION LIST ASPIRA-aA / MC 6125 AS PR2 PR3 Eppig T, Scholz K, Löffler A, et al. Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye J Cataract

More information

FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE

FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION Cataract treatment Insert your logo here 2 OK, I HAVE A CATARACT. NOW WHAT? WE UNDERSTAND YOUR

More information

Diffractive Optics. Multifocal Lenses. Correction of Pseudophakic Presbyopia with Multifocal IOLs. Basic Designs

Diffractive Optics. Multifocal Lenses. Correction of Pseudophakic Presbyopia with Multifocal IOLs. Basic Designs Correction of Pseudophakic Presbyopia with Multifocal IOLs GEORGE H.H. BEIKO, B.M.,B.Ch.,FRCSC ST. CATHARINES, CANADA ASSIST PROF, MCMASTER UNIV george.beiko@sympatico.ca AMO Tecnis MFIOL Alcon ReSTOR

More information

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs Patient information Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs Bring your vision into focus Good vision is a major contributor to the quality of life.

More information

Advanced Technology IOLs

Advanced Technology IOLs Introduction Advanced Technology IOLs Stephen V. Scoper, MD Virginia Eye Consultants 2013 Cataract surgery has a refractive element Patient expectations are increased Close is no longer good enough The

More information

Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO

Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO Ahmad-Reza Baghi, MD; Mohammad-Reza Jafarinasab, MD; Hossein Ziaei, MD; Zahra Rahmani, MD Shaheed Beheshti Medical University, Tehran,

More information

IOL Review and FLACS Update

IOL Review and FLACS Update IOL Review and FLACS Update James Lee, M.D. Assistant Professor Texas Tech University Health Sciences Center Department of Ophthalmology & Visual Sciences Disclosures All material and information for this

More information

The Miracle of Pi in Eye. Rajesh Khanna, MD

The Miracle of Pi in Eye. Rajesh Khanna, MD The Miracle of Pi in Eye Rajesh Khanna, MD Copyright 2013 Rajesh Khanna, MD All rights reserved. Pi in eye DEDICATION This book is dedicated to all my patients who placed their faith in me and trusted

More information

FOR PRECISE ASTIGMATISM CORRECTION.

FOR PRECISE ASTIGMATISM CORRECTION. WHY TORIC INTRAOCULAR LENSES? FOR PRECISE ASTIGMATISM CORRECTION. PATIENT INFORMATION Cataract treatment OK, I HAVE A CATARACT. NOW WHAT? WE UNDERSTAND YOUR CONCERNS WE CAN HELP. Dear patient, Discovering

More information

József Győry. Veszprem, Hungary

József Győry. Veszprem, Hungary Long term functional and morphological outcomes and patient satisfaction after cataract surgery with BiFlex M implantation with / without posterior central circular capsulorhexis (PCCC) József Győry Veszprem,

More information

Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens

Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens ARTICLE Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens José F. Alfonso, MD, PhD, Luis Fernández-Vega, MD, PhD, M. Begoña

More information

Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a D3.0 D addition

Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a D3.0 D addition ARTICLE Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a D3.0 D addition Thomas Kohnen, MD, Rudy Nuijts, MD, Pierre Levy, MD, Eduard Haefliger,

More information

Design and qualification of a diffractive trifocal optical profile for intraocular lenses

Design and qualification of a diffractive trifocal optical profile for intraocular lenses LABORATORY SCIENCE Design and qualification of a diffractive trifocal optical profile for intraocular lenses Damien Gatinel, MD, PhD, Christophe Pagnoulle, PhD, Yvette Houbrechts, PhD, Laure Gobin, PhD

More information

Contrast Sensitivity after Refractive Lens Exchange with A Multifocal Diffractive Aspheric Intraocular Lens

Contrast Sensitivity after Refractive Lens Exchange with A Multifocal Diffractive Aspheric Intraocular Lens Contrast Sensitivity after Refractive Lens Exchange with A Multifocal Diffractive Aspheric Intraocular Lens Teresa Ferrer-Blasco, PhD Santiago García-Lázaro, PhD César Albarrán-Diego, MSc 3 Lurdes Belda-Salmerón,

More information

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s. Instruction course: Refining the Refractive Error After Premium IOL s. Senior Instructor: Mounir Khalifa, MD Instructors: David Hardten,MD Scott MacRea,MD Matteo Piovella,MD Dr. Khalifa: Causes of refractive

More information

THE ASPHERIC PRELOADED INJECTION

THE ASPHERIC PRELOADED INJECTION New from STAAR for Safe and Easy Implantation THE ASPHERIC PRELOADED INJECTION S Y S T E M PRELOADED INJECTION SYSTEM FOR SIMPLE AND EASY IOL DELIVERY SAFE The KS3-Ai features an aspheric IOL preloaded

More information

Forget Most Everything! The Surgical Management of Presbyopia 2/23/2016. Refraction vs. Diffraction. Presbyopic IOL s Patient Expectations

Forget Most Everything! The Surgical Management of Presbyopia 2/23/2016. Refraction vs. Diffraction. Presbyopic IOL s Patient Expectations The Surgical Management of Presbyopia Presbyopic IOL s 2011 B I L L T U L L O, O D Patient Expectations What they say is I want to be able to read The Center of a Presbyope s World What they want is Accommodation

More information

Página 1 de 9 TopPage > Eye Care > Diagnostic > Wave-Front Analyzer KR-1W Wave-Front Analyzer KR-1W Perfection for Professionals : KR-1W Topcon, with its wealth of experience in designing and manufacturing

More information

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert University of Groningen Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert IMPORTANT NOTE: You are advised to consult the publisher's

More information

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES. XtraFocus THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES. CONTENT Based on the well-established principle of pinhole optics, this intraocular implant represents an innovative alternative for the

More information

Prospective sual evaluation of apodized diffractive intraocular lenses

Prospective sual evaluation of apodized diffractive intraocular lenses See discussions, stats, and author profiles for this publication at: https://www.researchgate.net/publication/6251759 Prospective sual evaluation of apodized diffractive intraocular lenses ARTICLE in JOURNAL

More information

Wide Diopter Range and Different Haptic Platforms

Wide Diopter Range and Different Haptic Platforms Monofocal Premium Material Innovative Optic Engineering Ultra Definition All Square 360 0 Enhanced Edge Wide Diopter Range and Different Haptic Platforms Best of Both Worlds Better Visual Quality Advanced

More information

Aberrations Before and After Implantation of an Aspheric IOL

Aberrations Before and After Implantation of an Aspheric IOL Ocular High Order Aberrations Before and After Implantation of an Aspheric IOL Fabrizio I. Camesasca, MD Massimo Vitali, Orthoptist Milan, Italy I have no financial interest to disclose Wavefront Measurement

More information

Visual and Optical Performances of Multifocal Intraocular Lenses with Three Different Near Additions: 6-Month Follow-Up

Visual and Optical Performances of Multifocal Intraocular Lenses with Three Different Near Additions: 6-Month Follow-Up Send Orders for Reprints to reprints@benthamscience.ae The Open Ophthalmology Journal, 2015, 9, 1-7 1 Open Access Visual and Optical Performances of Multifocal Intraocular Lenses with Three Different Near

More information

The Appearance of Images Through a Multifocal IOL ABSTRACT. through a monofocal IOL to the view through a multifocal lens implanted in the other eye

The Appearance of Images Through a Multifocal IOL ABSTRACT. through a monofocal IOL to the view through a multifocal lens implanted in the other eye The Appearance of Images Through a Multifocal IOL ABSTRACT The appearance of images through a multifocal IOL was simulated. Comparing the appearance through a monofocal IOL to the view through a multifocal

More information

Comparison between clinical results of two diffractive multifocal lenses with the same platform but different additions

Comparison between clinical results of two diffractive multifocal lenses with the same platform but different additions ARTICLE Comparison between clinical results of two diffractive multifocal lenses with the same platform but different additions Francisco Poyales, MD 1 ; Nuria Garzón, OD, MSc 1 ; Pedro Caro, MD 1 ; Oscar

More information

Evolution of the Cataract Patient

Evolution of the Cataract Patient Evolution of the Cataract Patient Mark Maraman O.D., M.S. Pacific Cataract and Laser Institute Disclosures I have no financial relationships or conflicts of interest with the manufacturers of any commercial

More information

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs The TECNIS Portfolio of presbyopia-correcting IOLs empowers you to hand-select a lens that can deliver the visual freedom your patients

More information

Medicontur IOLs: Materials & Design Main Characteristics

Medicontur IOLs: Materials & Design Main Characteristics Medicontur IOLs: Materials & Design Main Characteristics BALANCED TECHNOLOGY FOR OPTIMAL IOLs OPTICAL PERFORMANCE LONG TERM MATERIAL PERFORMANCE Material REFRACTIVE STABILITY TECHNOLOGY LOW PCO RATE STABILITY

More information

American National Standard for Ophthalmics. Extended Depth of Focus Intraocular Lenses

American National Standard for Ophthalmics. Extended Depth of Focus Intraocular Lenses January 23, 2018 rev. 7 ----------------------------------------------------------------------------------------------------------------------------- American National Standard (DRAFT) ANSI Z80.35 -----------------------------------------------------------------------------------------------------------------------------

More information

Maximising Treatment Outcomes with Premium IOL Technology. Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK.

Maximising Treatment Outcomes with Premium IOL Technology. Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK. Supplement February 2015 Maximising Treatment Outcomes with Premium IOL Technology Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK Sponsored by Introduction Thanks to advances in lens

More information

Binovision A new Approach for Seeing without Glasses

Binovision A new Approach for Seeing without Glasses Binovision A new Approach for Seeing without Glasses Sylvia Paulig MD WOC Abu Dhabi 2012 Sylvia Paulig MD Why did I need the Light Adjustable Lens? I, like most of us, was far away from a precise achievement

More information

Easy to identify: The color-coded forceps and scissors make identification during September September September 2016

Easy to identify: The color-coded forceps and scissors make identification during September September September 2016 Surgical Instruments Astigmatism neutral incision, less trauma: Thanks to a tube diameter of just 23 Gauge, the final incision size is only 1 mm. Unique vertical cutting: Scissors designed for enlarging

More information

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs The TECNIS portfolio of presbyopia-correcting IOLs empowers you to hand select a lens that can deliver the visual freedom your patients

More information

Postoperative Wavefront Analysis and Contrast Sensitivity of a Multifocal Apodized Diffractive IOL (ReSTOR) and Three Monofocal IOLs

Postoperative Wavefront Analysis and Contrast Sensitivity of a Multifocal Apodized Diffractive IOL (ReSTOR) and Three Monofocal IOLs Postoperative Wavefront Analysis and Contrast Sensitivity of a Multifocal Apodized Diffractive IOL (ReSTOR) and Three Monofocal IOLs Karolinne Maia Rocha, MD; Maria Regina Chalita, MD; Carlos Eduardo B.

More information

Optical Characteristics of Next Generation Dual Optic IOL

Optical Characteristics of Next Generation Dual Optic IOL Optical Characteristics of Next Generation Dual Optic IOL Scott Evans, MD Sanjeev Kasthurirangan, PhD Val Portney, PhD Financial Disclosures Scott Evans is an employee of Abbott Medical Optics Inc. Sanjeev

More information

Refractive Power / Corneal Analyzer. OPD-Scan III

Refractive Power / Corneal Analyzer. OPD-Scan III Refractive Power / Corneal Analyzer OPD-Scan III Comprehensive Vision Analysis and NIDEK, a global leader in ophthalmic and optometric equipment, has created the OPD-Scan III, the third generation aberrometer

More information

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert University of Groningen Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert IMPORTANT NOTE: You are advised to consult the publisher's

More information

Research Article In Vitro Aberrometric Assessment of a Multifocal Intraocular Lens and Two Extended Depth of Focus IOLs

Research Article In Vitro Aberrometric Assessment of a Multifocal Intraocular Lens and Two Extended Depth of Focus IOLs Hindawi Ophthalmology Volume 2017, Article ID 7095734, 7 pages https://doi.org/10.1155/2017/7095734 Research Article In Vitro Aberrometric Assessment of a Multifocal Intraocular Lens and Two Extended Depth

More information

University of Groningen. Young eyes for elderly people van Gaalen, Kim

University of Groningen. Young eyes for elderly people van Gaalen, Kim University of Groningen Young eyes for elderly people van Gaalen, Kim IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the

More information

Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation

Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation J CATARACT REFRACT SURG - VOL 31, SEPTEMBER 2005 Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation Antonio Rodríguez-Galietero, MD, PhD, FEBO,

More information

EXCHANGE. Financial Disclosure. Clinical pearls In advanced anterior segment surgery being able to do a IOL exchange is a must. Why Do an Exchange

EXCHANGE. Financial Disclosure. Clinical pearls In advanced anterior segment surgery being able to do a IOL exchange is a must. Why Do an Exchange Financial Disclosure D. Ayres, MD Cornea Service IOLBrandon Wills Eye Hospital EXCHANGE Alcon Allergan AMO Bausch and Lomb TearScience BioTissue Why Do an Exchange Refractive surprise after cataract surgery

More information

Education is the key to understanding

Education is the key to understanding www.eyeworld.org Highlights from 2007 ASCRS ASOA Symposium & Congress June 2007 2007 ASCRS ASOA San Diego Show Daily Supplement AcrySof ReSTOR Lens and ReZoom: The First 15 Patients Supported by an unrestricted

More information

Customized intraocular lenses

Customized intraocular lenses Customized intraocular lenses Challenges and limitations Achim Langenbucher, Simon Schröder & Timo Eppig Customized IOL what does this mean? Aspherical IOL Diffractive multifocal IOL Spherical IOL Customized

More information

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations Seema Somani PhD, Ashley Tuan OD, PhD, and Dimitri Chernyak PhD VISX Incorporated, 3400 Central Express Way, Santa Clara, CA

More information

IOL Predictions for the Coming Year

IOL Predictions for the Coming Year IOL Predictions for the Coming Year Where are lens technologies headed in 2015 and beyond? BY OLIVER FINDL, MD, MBA, FEBO; SAMUEL MASKET, MD; RICHARD PACKARD, MD, DO, FRCS, FRCOphth; AND LILIANA WERNER,

More information

LASIK & Refractive Surgery

LASIK & Refractive Surgery LASIK & Refractive Surgery LASIK PRK ICL RLE Monovision + + + Understanding the Basics: Why You Need Vision Correction What is a refraction and refractive error? First and foremost, we should give you

More information

Comparative Study Between the High Order Aberrations Before and After Cataract Surgery Using Two Different Types of IOLS

Comparative Study Between the High Order Aberrations Before and After Cataract Surgery Using Two Different Types of IOLS Cronicon OPEN ACCESS EC OPHTHALMOLOGY Research Article Comparative Study Between the High Order Aberrations Before and After Cataract Surgery Using Two Different Types of IOLS Ahmed Abdelkareem Elmassry*,

More information

Vision for What They Love.

Vision for What They Love. Vision for What They Love. INDICATIONS: The TECNIS Symfony Extended Range of Vision IOL, model ZXR, is indicated for primary implantation for the visual correction of aphakia, in adult patients with less

More information