Adding scale bars to images
|
|
- Gordon McDaniel
- 6 years ago
- Views:
Transcription
1 Adding scale bars to images ImageJ/FIJI IVision Nikon Nis- Elements Imaris 8 Imagej/FIJI 1. If you are viewing images acquired in Micro- Manager and you selected the lens before acquiring the images then the images should have the correct scaling, in which case jump to step 3. If not then read on. 2. To set the image calibration (µm/pixel value) go to Analyse>Set Scale Fill out the information in the Set Scale box, this will vary depending on the microscope and objective used: If you tick the Global option, it will set the scale for all images currently open 3. Once you have set the scale, you can then add a scale bar. Go to Analyse, Tools and Scale Bar The ScaleBar Plus dialogue will appear: Decide the size of scale bar you want, as well as its colour, location and whether or not you want text:
2 4. Once you are happy, remember to save your image File, Save As, Tiff A general note about the scale of your images The scale stays the same if you crop an image. So if 100µm = 103 pixels in A, 100µm = 103 pixels in B A B The scale will change if you resize an image (C) e.g. From 1024 x 1024 to 512 x 512 In this image your scale with be half as large. There are two approaches to this. Either note the factor by which you have reduced your image size and then alter the scale bar accordingly when you make it. Or have the scale bar on the image when your reduce it. (easier) C
3 Nikon Nis- Elements Images saved in Nikon nd2 format contain metadata which along with other things stores the image calibration (µm/pixel value). This means you merely need to add the scale bar. A scale bar can be added to any image by selecting the scale bar button on the right hand side of the window. If you select the down arrow next to it you can enter the Scale properties menu, here you can change the size/colour etc of the scale bar. Scale button If you create a snapshot of an image Edit>Create Full View Snapshot, the scale bar will be burned on and cannot be removed.
4 Imaris 8 Some image files such as Nikon nd2 image store Metadata along with the image. Part of this data is the image calibration (µm/pixel value). If your image is not already calibrated you can set the value in More>Edit>Image Properties. In the Geometry menu change the Voxel size as required for XYZ. In Imaris you can adjust the size, width/height/font by interacting with the scale bar itself using the mouse cursor. When the cursor becomes a crosshair this means you can move the scale bar around. If it is a double headed arrow you can adjust the scale bars size. To save a copy of the image with the scale bar added you can capture a Snapshot. Select the Snapshot icon from the top of the window. A snapshot preview will appear in the left margin. Here you can adjust various options and preview the snapshot before it is saved. See Imaris guide for more in depth information
5 IVision scale bar script Open the scale bar script from disk Script>Open script Select Go to shared scripts folder button Find the Scale bar script in the list and open The script window will open, there is a second window associated with the script which contains lots of buttons. Use the Save As button to save a copy of the script to your own folder. Enter the required values: Objective magnification- Magnification of the lens used to acquire the image. Zoom- Required when images were captured on a microscope with zoom optics (stereo/macroscope). Scaling factor- The magnification added by the tube lens if any. Binning- Defined when setting up the acquisition, also reported in the IVision status window. CCD pixel size- dimensions of the CCD s photodiodes (camera dependent) Coolsnap/Orca/Retiga (fluorescence) = 6.45µm Micropublisher (colour) = 3.4µm (5 MP), 3.45 (3MP) Length in microns- Enter the length of the scale bar you wish to appear on the image. Batch processing All options below the horizontal line in the script are to configure adding a scale bar to many open images. Ignore this section if only applying the scale to a single image. Open all the images that you wish to apply a scale bar (must be same magnification etc). Copy scale bar to all open images (required) Assumes all open images require a scale bar Relocate scale position on each image (optional) You will likely have to move the scale bar on each image so it doesn t obscure any important image features. If you do not select this option, the scale bar is placed in the same position on all images. Select Folder for saved images (required) The scale bars will be stamped on all images and saved as a separate copy and scale will be appended to the filename
Standard Operating Procedure
CENTER FOR NANOSCALE SCIENCE AND ENGINEERING Standard Operating Procedure Microscope Software Brian Wajdyk Page 1 of 6 Important Images are not to be saved to the computer. They will be deleted without
More informationREMEMBER: You have 5GB of disk space on this microscope. Check before you start if you have room for your experiment. If not delete your old data.
1 Use of the Zeiss LSM 510 Inverted Firstly please be aware that this microscope should be treated with respect and care at all times. Rules of use: This Microscope can only be used by Masters by Research
More informationMeasurement calibration in Video ToolBox Software. An example using a ruler
Measurement calibration in Video ToolBox Software An example using a ruler Video ToolBox is capable of precise measurement using a number of different measurement tools. To use the measurement tools it
More informationGXCapture 7 User Guide
Operation Manual for GXCapture GXCapture 7 User Guide GT Vision Ltd Version: 7 Operation Manual for GXCapture Please note that due to our policy of continuous product enhancement parts of this manual may
More informationManaging images with NewZapp
Managing images with NewZapp This guide is for anyone using the NewZapp Fixed editor as opposed to the Drag and Drop editor. The Image Manager is where images are uploaded and stored in your NewZapp account
More informationUsing the Nikon TE2000 Inverted Microscope
Wellcome Trust Centre for Human Genetics Molecular Cytogenetics and Microscopy Core Using the Nikon TE2000 Inverted Microscope Fluorescence image acquisition using Scanalytic s IPLab software and the B&W
More informationGlobiScope Analysis Software for the Globisens QX7 Digital Microscope. Quick Start Guide
GlobiScope Analysis Software for the Globisens QX7 Digital Microscope Quick Start Guide Contents GlobiScope Overview... 1 Overview of home screen... 2 General Settings... 2 Measurements... 3 Movie capture...
More informationNikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON
N-SIM guide NIKON IMAGING CENTRE @ KING S COLLEGE LONDON Starting-up / Shut-down The NSIM hardware is calibrated after system warm-up occurs. It is recommended that you turn-on the system for at least
More informationDIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0
DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0 PixeLINK for Microscopy Applications PixeLINK will work with you to choose and integrate the optimal USB 3.0 camera for your microscopy project. Ideal for use
More informationTitle: Nikon A1R Confocal User Manual
Title: Nikon A1R Confocal User Manual Date of first issue: 23/10/2015 Date of review: Version: Admin For assistance or to report an issue Office: CG.07 or CG.05 Email: Igmm-imaginghelpdesk@igmm.ed.ac.uk
More informationWe recommend downloading the latest core installer for our software from our website. This can be found at:
Dusk Getting Started Installing the Software We recommend downloading the latest core installer for our software from our website. This can be found at: https://www.atik-cameras.com/downloads/ Locate and
More informationJeol JEM Responsible personell: Endy ( ) Online booking is compulsory!
Jeol JEM 1230 Responsible personell: Endy (45279377) Online booking is compulsory! After training you will have access to working alone on the instrument. All insertion of samples is done by responsible
More informationNasmyth Ultraview Vox User Protocol
Nasmyth Ultraview Vox User Protocol Switch on all wall sockets labelled Nasmyth, switch camera on (power supply located on table behind monitor), switch on laser switch in laser rack, switch computer on
More informationUser manual for Olympus SD-OSR spinning disk confocal microscope
User manual for Olympus SD-OSR spinning disk confocal microscope Ved Prakash, PhD. Research imaging specialist Imaging & histology core University of Texas, Dallas ved.prakash@utdallas.edu Once you open
More informationScanning Guide for Adobe Photoshop
Scanning Guide for Adobe Photoshop This guide is written for Adobe Photoshop CS2. It describes how to use the scanner through the Import Twain function from within Photoshop, so access to Adobe Photoshop
More informationZeiss AxioImager.Z2 Brightfield Protocol
Zeiss AxioImager.Z2 Brightfield Protocol 1) System Startup Please note put sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge
More informationDiskovery Spinning Disk Guide
Diskovery Spinning Disk Guide qbi.microscopy@uq.edu.au Getting started The microscope and its peripherals (Fig. 1a) should always be turned on, but if they are not, turn them on in the following way: 1.
More informationIn the following sections, if you are using a Mac, then in the instructions below, replace the words Ctrl Key with the Command (Cmd) Key.
Mac Vs PC In the following sections, if you are using a Mac, then in the instructions below, replace the words Ctrl Key with the Command (Cmd) Key. Zoom in, Zoom Out and Pan You can use the magnifying
More informationAdobe Photoshop CC 2018 Tutorial
Adobe Photoshop CC 2018 Tutorial GETTING STARTED Adobe Photoshop CC 2018 is a popular image editing software that provides a work environment consistent with Adobe Illustrator, Adobe InDesign, Adobe Photoshop,
More informationPoint Calibration. July 3, 2012
Point Calibration July 3, 2012 The purpose of the Point Calibration process is to generate a map of voltages (for galvos) or motor positions of the pointing device to the voltages or pixels of the reference
More informationUser Manual. Copyright 2010 Lumos. All rights reserved
User Manual The contents of this document may not be copied nor duplicated in any form, in whole or in part, without prior written consent from Lumos. Lumos makes no warranties as to the accuracy of the
More informationAdobe Photoshop CS5 Tutorial
Adobe Photoshop CS5 Tutorial GETTING STARTED Adobe Photoshop CS5 is a popular image editing software that provides a work environment consistent with Adobe Illustrator, Adobe InDesign, Adobe Photoshop
More informationTitle: Leica SP5 Confocal User Manual
Title: Leica SP5 Confocal User Manual Date of first issue: 23/10/2015 Date of review: Version: Admin For assistance or to report an issue Office: CG07 or 05 Email: Igmm-imaginghelpdesk@igmm.ed.ac.uk Website:
More informationQuintic Software Tutorial 3
Quintic Software Tutorial 3 Take a Picture 1 Tutorial 3 Take a Picture Contents Page 1. Photo 2. Photo Sequence a. Add shapes and angles 3. Export Analysis 2 Tutorial 3 Take a Picture 1. Photo Open the
More informationμscope Microscopy Software
μscope Microscopy Software Pixelink μscope Essentials (ES) Software is an easy-to-use robust image capture tool optimized for productivity. Pixelink μscope Standard (SE) Software had added features, making
More informationISCapture User Guide. advanced CCD imaging. Opticstar
advanced CCD imaging Opticstar I We always check the accuracy of the information in our promotional material. However, due to the continuous process of product development and improvement it is possible
More informationMEASUREMENT CAMERA USER GUIDE
How to use your Aven camera s imaging and measurement tools Part 1 of this guide identifies software icons for on-screen functions, camera settings and measurement tools. Part 2 provides step-by-step operating
More informationOPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop
OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop 1. Log in usage using the SMIF web site 2. Turn power
More informationHow To Resize & Crop Images to 1024 x 768 Pixels For Projection
SCOPE This document covers the process cropping and resizing an image to a suitable size in pixels for digital projection. This process assumes the use of XnView (see Appendix), a free image editor from
More informationWidefield 1. Switching on
Widefield 1 Switching on 1. Ignite DG5 lamp - must be switched on first (if previous user has switched off, wait 30 min before igniting) 2. Wait 5s and then turn on the main DG5 controller switch. 3. DG5
More informationBrightfield Microscopy and Image Acquisition on Spotcam1. by Ryan Taylor/Nancy Kleene Last modified 10/02/05 by Birgit Ehmer
Brightfield Microscopy and Image Acquisition on Spotcam1 by Ryan Taylor/Nancy Kleene Last modified 10/02/05 by Birgit Ehmer Log onto the computer. Enter your username and password to log onto the server.
More informationResizing Images for Competition Entry
Resizing Images for Competition Entry Dr Roy Killen, EFIAP, GMPSA, APSEM TABLE OF CONTENTS Some Basic Principles 1 An Simple Way to Resize and Save Files in Photoshop 5 An Alternative way to Resize Images
More informationNikon A1Rsi Confocal Start-Up Sequence
1. Turn the key on the Nikon LUN-V Laser Launch. Nikon A1Rsi Confocal Start-Up Sequence 2. Press the button the left side of the A1Rsi Controller unit. 3. Turn on the power strip underneath the microscope.
More informationQImaging. All rights reserved. QUICK START GUIDE
QUICK START GUIDE The QCapture Suite PLUS installer package is available for download on the QImaging website: http://www.qimaging.com/support/downloads/ Once downloaded, the installer folder will be stored
More informationMC3 Motion Control System Shutter Stream Quickstart
MC3 Motion Control System Shutter Stream Quickstart Revised 7/6/2016 Carousel USA 6370 N. Irwindale Rd. Irwindale, CA 91702 www.carousel-usa.com Proprietary Information Carousel USA has proprietary rights
More informationZeiss Deconvolution Microscope: A Quick Guide
Zeiss Deconvolution Microscope: A Quick Guide Start-up Uncover microscope. Do not put dust cover on the floor. Plug in both cameras. The default camera is the AxioCam HRm (monochrome camera) for fluorescence
More informationCELL-IQ IMAGEN USER MANUAL
CELL-IQ IMAGEN USER MANUAL FOR CELL-IQ, FOR YOUR RESEARCH NEEDS 2010 Chip-Man Technologies Ltd. All rights reserved. Protected by copyright law and international treaties. Contents 0 Introduction 2 Cell-IQ
More informationADDENDUM 2 SPECIMEN SCANNING PROTOCOL AT THE COMPTON HERBARIUM. September Prepared by Michelle Smith
ADDENDUM 2 SPECIMEN SCANNING PROTOCOL AT THE COMPTON HERBARIUM September 2012 Prepared by Michelle Smith INTRODUCTION The following specimen and text scanning protocol was developed during the African
More informationUser Manual Veterinary
Veterinary Acquisition and diagnostic software Doc No.: Rev 1.0.1 Aug 2013 Part No.: CR-FPM-04-022-EN-S 3DISC, FireCR, Quantor and the 3D Cube are trademarks of 3D Imaging & Simulations Corp, South Korea,
More informationZeiss LSM 880 Protocol
Zeiss LSM 880 Protocol 1) System Startup Please note put sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge for unused time.
More informationMighty Scope 5M. Instruction Manual. aveninc.com
Mighty Scope 5M Instruction Manual aveninc.com Contents Features 2 Specifications 2 Contents 2 PC System Requirements 3 Driver Installation Procedure 3 Getting Started 3 Software Installation (PC) 4 Mighty
More informationProudly serving laboratories worldwide since 1979 SPECIFICATIONS
www.ietltd.com Proudly serving laboratories worldwide since 1979 SPECIFICATIONS Scan RDI Specifications System Components Main analytical console Laser Module CRT Printer Data Manager Motorized stage (option)
More informationThermaViz. Operating Manual. The Innovative Two-Wavelength Imaging Pyrometer
ThermaViz The Innovative Two-Wavelength Imaging Pyrometer Operating Manual The integration of advanced optical diagnostics and intelligent materials processing for temperature measurement and process control.
More informationBi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging
Bi/BE 227 Winter 2016 Assignment #3 Adding the third dimension: 3D Confocal Imaging Schedule: Jan 20: Assignment Jan 20-Feb 8: Work on assignment Feb 10: Student PowerPoint presentations. Goals for this
More informationBlab Gallery Uploads: How to Reduce and/or Rotate Your Photo Last edited 11/20/2016
Blab Gallery Uploads: How to Reduce and/or Rotate Your Photo Contents & Links QUICK LINK-JUMPS to information in this PDF document Photo Editors General Information Includes finding pre-installed editors
More informationOlympus xcellence Software - basic user guide
Olympus xcellence Software - basic user guide This is a basic overview of setting up time lapse experiments using Olympus's xcellence software on BIU's IX81 inverted phase contrast system - the software
More informationZeiss LSM 780 Protocol
Zeiss LSM 780 Protocol 1) System Startup F Please note the sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge for unused time.
More informationWelcome 1. Precaution
Table of Contents EN Precaution....2 Preparation.. 4 Standard accessories....4 Parts Names & Functions...5 Computer System requirements.... 6 Technical Specifications 7 Install the software.. 7 Start Microscope.8
More informationDxO Optics Pro v3.5 User Manual 1/153
DxO Optics Pro v3.5 User Manual 1/153 DXO OPTICS PRO V3.5 USER MANUAL Table of Contents OVERVIEW...3 GETTING STARTED OPERATING MODES...5 FULLY AUTOMATIC MODE...8 WORKSPACE ANATOMY...9 TOOLBAR...11 MENUS...12
More informationSwept-Field User Guide
Swept-Field User Guide Note: for more details see the Prairie user manual at http://www.prairietechnologies.com/resources/software/prairieview.html Please report any problems to Julie Last (jalast@wisc.edu)
More informationHow to Create Website Banners
How to Create Website Banners In the following instructions you will be creating banners in Adobe Photoshop Elements 6.0, using different images and fonts. The instructions will consist of finding images,
More informationImage Editing and Measurement Software. User Manual
Digital Viewer II TM Digital Microscope Image Editing and Measurement Software User Manual Version: 2.1.1.2 1 DIGITAL VIEWER II TM DIGITAL MICROSCOPE... 1 IMAGE EDITING AND MEASUREMENT SOFTWARE... 1 USER
More informationZeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling
Zeiss LSM 510 Confocor III Training Notes Center for Cell Analysis & Modeling Confocor 3 Start Up Go to System Module Turn on Main Switch, System/ PC, and Components Switches Do you need the arc lamp?
More informationGETTING STARTED. 0 P a g e B a s i c s o f A d o b e P h o t o s h o p A g a P r i v a t e I n s t i t u t e f o r c o m p u t e r s c i e n c e
GETTING STARTED 0 P a g e B a s i c s o f A d o b e P h o t o s h o p Adobe Photoshop: is a popular image editing software that provides a work environment consistent with Adobe Illustrator, Adobe InDesign,
More informationScanArray Overview. Principle of Operation. Instrument Components
ScanArray Overview The GSI Lumonics ScanArrayÒ Microarray Analysis System is a scanning laser confocal fluorescence microscope that is used to determine the fluorescence intensity of a two-dimensional
More informationImaging Features Available in HTML5. it just makes sense
Imaging Features Available in HTML5 it just makes sense August, 2018 Imaging Features Available in HTML5 As part of the 5.2 SP1 release, the Images functionality is now available in HTML5 and provides
More informationImporting and processing gel images
BioNumerics Tutorial: Importing and processing gel images 1 Aim Comprehensive tools for the processing of electrophoresis fingerprints, both from slab gels and capillary sequencers are incorporated into
More informationCHROMACAL User Guide (v 1.1) User Guide
CHROMACAL User Guide (v 1.1) User Guide User Guide Notice Hello and welcome to the User Guide for the Datacolor CHROMACAL Color Calibration System for Optical Microscopy, a cross-platform solution that
More informationStitching distortion-free mosaic images for QWA using PTGui. Georg von Arx
Stitching distortion-free mosaic images for QWA using PTGui Georg von Arx Index A. Introduction and overview... 2 B. Taking microscopic images... 2 C. Installing PTGui... 3 D. Initial Setup... 3 E. Preparing
More informationManual. Cell Border Tracker. Jochen Seebach Institut für Anatomie und Vaskuläre Biologie, WWU Münster
Manual Cell Border Tracker Jochen Seebach Institut für Anatomie und Vaskuläre Biologie, WWU Münster 1 Cell Border Tracker 1. System Requirements The software requires Windows XP operating system or higher
More informationImage and Data Acquisition
Image and Data Acquisition LCP Image Acquisition Procedures This section provides guidelines for scanning images that will be added to the LCP image archive. By scanning the image, we obtain a digital
More informationQuick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s
LSM 5 MP, LSM 510 and LSM 510 META M i c r o s c o p y f r o m C a r l Z e i s s Quick Guide Laser Scanning Microscopes LSM Software ZEN 2007 August 2007 We make it visible. Contents Page Contents... 1
More informationRENISHAW INVIA RAMAN SPECTROMETER
STANDARD OPERATING PROCEDURE: RENISHAW INVIA RAMAN SPECTROMETER Purpose of this Instrument: The Renishaw invia Raman Spectrometer is an instrument used to analyze the Raman scattered light from samples
More informationBatch Counting of Foci
Batch Counting of Foci Getting results from Z stacks of images. 1. First it is necessary to determine suitable CHARM parameters to be used for batch counting. First drag a stack of images taken with the
More informationSimplified Instructions: Olympus Widefield Microscope S1230
Contents General Microscope Operation Simple Image Capture Multi-Wavelength Capture Z-Series Timelapse Combining Capture Modes Synopsis of Other Functions Pages 2-23 24-40 41-47 48-56 57-59 60-68 69-83
More informationThings to check before start-up.
Byeong Cha Page 1 11/24/2009 Manual for Leica SP2 Confocal Microscope Enter you name, the date, the time, and the account number in the user log book. Things to check before start-up. Make sure that your
More informationuser guide for windows creative learning tools
user guide for windows creative learning tools Page 2 Contents Welcome to MissionMaker! Please note: This user guide is suitable for use with MissionMaker 07 build 1.5 and MissionMaker 2.0 This guide will
More informationMullingar Camera Club Basic introduction to Digital Printing using Photoshop CC.
Mullingar Camera Club Basic introduction to Digital Printing using Photoshop CC. Table of Contents Course aims: 1 Course presentation notes: 1 Introducing Photoshop: 1 Adjusting the Brightness or Contrast
More informationSource photo, sketchbook collage and digital collage
Source photo, sketchbook collage and digital collage Develop a mixed media project using traditional media, digital camera, scanner and image manipulation software. This technique encourages a creative
More informationOlympus Digital Microscope Camera (DP70) checklist
Smith College - July 2005 Olympus Digital Microscope Camera (DP70) checklist CONTENT, page no. Camera Information, 1 Startup, 1 Retrieve an Image, 2 Microscope Setup, 2 Capture, 3 Preview. 3 Color Balans,
More informationLSM 510 Meta Training Notes
LSM 510 Meta Training Notes Turning on the system Turn on X-Cite power supply. This supplies light for epifluorescence for viewing your samples through the microscope. Turn on the remote control switch.
More informationKigamo Scanback which fits in your view camera in place of conventional film.
What's included Kigamo Scanback which fits in your view camera in place of conventional film. SCSI Cable to connect your Scanback to the host computer. A 3-meter SCSI cable is standard. Kigamo also has
More informationTRAINING MANUAL. Olympus FV1000
TRAINING MANUAL Olympus FV1000 September 2014 TABLE OF CONTENTS A. Start-Up Procedure... 1 B. Visual Observation under the Microscope... 1 C. Image Acquisition... 4 A brief Overview of the Settings...
More informationDigital Imaging Group. 20th June Working at the High End
Digital Imaging Group 20th June 2014 Working at the High End Processing RAW files in Adobe Camera Raw (ACR) (and a little about high pixel count cameras later) What is RAW? The RAW file captures information
More informationMonaco ColorWorks User Guide
Monaco ColorWorks User Guide Monaco ColorWorks User Guide Printed in the U.S.A. 2003 Monaco Systems, Inc. All rights reserved. This document contains proprietary information of Monaco Systems, Inc. No
More informationImage Pro Ultra. Tel:
Image Pro Ultra www.ysctech.com info@ysctech.com Tel: 510.226.0889 Instructions for installing YSC VIC-USB and IPU For software and manual download, please go to below links. http://ysctech.com/support/ysc_imageproultra_20111010.zip
More informationImprove your photos and rescue old pictures
PSPRO REVISTED Nov 5 2007 Page 1 of 7 Improve your photos and rescue old pictures This guide gives tips on how you can use Paint Shop5 and similar free graphic programmes to improve your photos. It doesn
More informationReference and User Manual May, 2015 revision - 3
Reference and User Manual May, 2015 revision - 3 Innovations Foresight 2015 - Powered by Alcor System 1 For any improvement and suggestions, please contact customerservice@innovationsforesight.com Some
More informationLeica SP8 TCS Users Manual
Leica SP8 TCS Users Manual Follow the procedure for start up and log on as posted in the lab. Please log on with your account only and do not share your password with anyone. We track and confirm usage
More informationNIS-Elements: Grid to ND Set Up Interface
NIS-Elements: Grid to ND Set Up Interface This document specifies the set up details of the Grid to ND macro, which is included in material # 97157 High Content Acq. Tools. This documentation assumes some
More informationUser Guide of ISCapture
User Guide of ISCapture For Windows2000/XP/Vista(32bit/64bit)/Win7(32bit/64bit) Xintu Photonics Co., Ltd. Version: 2.6 I All the users of Xintu please kindly note that the information and references in
More informationZEISS LSM 710 CONFOCAL MICROSCOPE USER MANUAL
ZEISS LSM 710 CONFOCAL MICROSCOPE USER MANUAL START THE SYSTEM... 2 START ZEN SOFTWARE... 3 SET THE TEMPERATURE AND THE CO2 CONTROLLERS... OBSERVATION AT OCULARS... 5 STATIF PRESENTATION... 6 ACQUIRE ONE
More informationBy Washan Najat Nawi
By Washan Najat Nawi how to get started how to use the interface how to modify images with basic editing skills Adobe Photoshop: is a popular image-editing software. Two general usage of Photoshop Creating
More informationZeiss 880 Training Notes Zen 2.3
Zeiss 880 Training Notes Zen 2.3 1 Turn on the HXP 120V Lamp 2 Turn on Main Power Switch Turn on the Systems PC Switch Turn on the Components Switch. 3 4 5 Turn on the PC and log into your account. Start
More informationNote: These directions are for Paint on WindowsXp and Vista. At the end of this tutorial are features of Paint for Windows 7.
The Power of Paint Note: These directions are for Paint on WindowsXp and Vista. At the end of this tutorial are features of Paint for Windows 7. Your Assignment Using Paint 1. Resize an image 2. Crop an
More informationFile Formats and the Properties of Digital Images and Graphics Instructions and answers for teachers
Unit R082 Creating digital graphics File Formats and the Properties of Digital Images and Graphics Instructions and answers for teachers These instructions should accompany the OCR resource File Formats
More informationDigitiser USER MANUAL
Digitiser USER MANUAL Table of Contents Chapter 1 - Introduction 1 Overview... 3 General information... 4 What s new... 5 Software installation... 6 Software registration... 7 Chapter 2 - The Stick Figure
More informationFLIM Protocol. 1. Install IRF sample on the microscope using the stage insert. IRF sample options include urea crystals or BBO crystal.
Data Collection FLIM Protocol 1. Install IRF sample on the microscope using the stage insert. IRF sample options include urea crystals or BBO crystal. 2. Install appropriate SHG filter. (890nm = 445/20nm,
More informationMIF ZEISS LSM510 CONFOCAL USER PROTOCOL
MIF ZEISS LSM510 CONFOCAL USER PROTOCOL START-UP Turn on the Mercury Bulb Power Supply (if needed). Power-on the Control Box. Turn on the computer. Open the LSM 510 software. Choose Scan New Images and
More informationWhen you complete this assignment you will:
Objjectiives When you complete this assignment you will: 1. Set-up menus and drawing for designing modeling problems. 2. become familiar with the Sketch menu tools and commands. 3. Produce a three-dimensional
More informationThe ideal K-12 science microscope solution. User Guide. for use with the Nova5000
The ideal K-12 science microscope solution User Guide for use with the Nova5000 NovaScope User Guide Information in this document is subject to change without notice. 2009 Fourier Systems Ltd. All rights
More informationEPIFLUORESCENCE &/OR BRIGHTFIELD MICROSCOPY
EPIFLUORESCENCE &/OR BRIGHTFIELD MICROSCOPY TURN ON THE FOLLOWING EQUIPMENT The fluorescent light (if needed) The power strip for the microscope and accessories The CoolSNAP HQ camera on the right (Turn
More informationHoriba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)
Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120) Please contact Dr. Amanda Henkes for training requests and assistance: 979-862-5959, amandahenkes@tamu.edu Hardware LN 2 FTIR FTIR camera 1
More informationGCS Member Photo & Image Editor
GCS Member Photo & Image Editor Golf Computer Systems Image Editor Version 1.12.8.00 31 August 2010 Introduction The Golf Computer Systems Membership Management System (MMS) and FACTS (Facility and Activity
More informationA. Selecting. Example: Start the GIMP by clicking Start, choose Gimp and GIMP 2 from the menu. Open the Keys.jpg image from your course folder.
A. Selecting Open the Keys.jpg image from your course folder. From the Layer menu, choose New Layer. Ensure Transparency is ticked Click OK. The Layer dialog now shows two layers. Page 1 Click the Background
More informationContents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING
Operations Guide Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING Nikon Eclipse 90i Operations Guide STARTUP Startup Powering Up Fluorescence
More informationinphoto ID PS Automatic ID photography With Canon PowerShot camera User Guide
inphoto ID PS Automatic ID photography With Canon PowerShot camera User Guide 2018 Akond company Phone/fax: +7(812)384-6430 Cell: +7(921)757-8319 e-mail: info@akond.net akondsales@gmail.com http://www.akond.net
More information1. What is SENSE Batch
1. What is SENSE Batch 1.1. Introduction SENSE Batch is processing software for thermal images and sequences. It is a modern software which automates repetitive tasks with thermal images. The most important
More informationLet s start by making a pencil, that can be used to draw on the stage.
Paint Box Introduction In this project, you will be making your own paint program! Step 1: Making a pencil Let s start by making a pencil, that can be used to draw on the stage. Activity Checklist Start
More informationLowDose for JEOL. --Software LowDose and Advanced Data Acquisition. Version 1.1
LowDose for JEOL --Software LowDose and Advanced Data Acquisition Version 1.1 1. Introduction This is the LowDose software for the user of JEOL electron microscopes. The LowDose software is a Plug-In for
More information