J: Emergency lighting (optional) L: pole type X: ceiling type

Size: px
Start display at page:

Download "J: Emergency lighting (optional) L: pole type X: ceiling type"

Transcription

1 Lighting Technology Light Fittings for Fluorescent Lamp BAY Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone and Zone Zone and Zone Single or dual lamp versions Available lamp and power Fluorescent lamps: 8W x, 36W x, 8W x, 8W x, 36W x, 8W x. LED lamps: 9W x, 9W x, 8W x, 8W x. The glass tube stands 4J impact. Enclosure in copper-free aluminium, powder coated external surface, yellow (RAL). Electronic ballast, wide voltage range, rapi d starting, stable performance, power factor.9. End of lamp life (EOL) rectification effect protection. Only fluorescent lamp with emergency ligh ting function, LED Catalogue number logic lamp without such function. BAY- x J: Emergency lighting (optional) Mounting L: pole type X: ceiling type Lamp number Lamp power (W) LED: Only for LED lamp Explosion-proof light fittings for fluorescent lamp Zones &; & /8 General Catalogue..

2 Light Fittings for Fluorescent Lamp BAY Series Explosion-proof Light Fittings for Fluorescent Lamp Technical data Explosion-proof light fittings for fluorescent lamp BAY- x Explosion protection Gas explosion protection Dust explosion protection II G Ex d IIC T6 Gb Ex d IIC T6 Gb Ex t IIIC T8 Db IP66 Certificates Conformity to standards Material Enclosure Glass tube Ballast Wire guard (optional) Exposed fastener Lamp Lamp brand Lamp power (W) Rated voltage Earthing protection Degree of protection Ambient temperature Terminal Cable entries Single lamp Dual lamp Cable gland (optional) LCIE 9 ATEX 346; IECEx FM (USA); POCC CN..B3637(Russia) EN 679-: 9, EN 679-: 7 IEC 679-: 7, IEC 679-: 7, IEC 679-3: 8 Copper-free aluminium, powder coated external surface, yellow (RAL) Toughened glass, stands 4J impact Electronic ballast Powder coated carbon steel (white) or stainless steel Stainless steel PHILIPS T8 (supplied with the light fittings) 8W x 8W x 36W x 36W x 8W x 8W x 3V AC /6Hz M (internal & external earth bolts) IP (-6 + ) 3 x. 4mm (L+N+PE) 3 x M x. Plug 4 x M x. Plug DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/. Selection table Type/Ordering code Lamp power(w) Weight(kg) Type/Ordering code Lamp power(w) Weight(kg) BAY-8 x X 8 x.6 BAY-8 x X 8 x.6 BAY-8 x L 8 x 6. BAY-8 x L 8 x. BAY-36 x X 36 x 8.8 BAY-36 x X 36 x 6.3 BAY-36 x L 36 x 9.3 BAY-36 x L 36 x 6.8 BAY-8 x X 8 x.4 BAY-8 x X 8 x 8.3 BAY-8 x L 8 x.8 BAY-8 x L 8 x 9. Note: Products above include all the mounting accessories listed in Mounting Accessories & Spare Parts Table (see P/4 ). Dimension drawings (all dimensions in mm) - subject to alteration BAY- x BAY- x General Catalogue.. /9

3 Light Fittings for Fluorescent Lamp BAY Series Explosion-proof Light Fittings for Fluorescent Lamp Technical data Explosion-proof emergency light fittings for fluorescent lamp BAY- x J Explosion protection Gas explosion protection Dust explosion protection Certificates Conformity to standards Material Enclosure Glass tube Emergency unit Ballast Wire guard (optional) Exposed fastener Lamp Lamp brand Lamp power (W) Emergency power (W) Emergency start time Charge time Emergency lighting time Rated voltage Earthing protection Degree of protection Ambient temperature Terminal Cable entries Cable gland (optional) II G Ex d IIC T6 Gb II D Ex t IIIC T8 Db IP66 LCIE ATEX ; FM (USA); GOST.R (Russia); IECEx EN 679-: 9, EN 679-: 7, EN 679-3: 9 IEC 679-: 7, IEC 679-: 7, IEC 679-3: 8 Copper-free aluminium, powder coated external surface, yellow (RAL) Toughened glass, stands 4J impact Special emergency controller and NI-MH battery pile, with protection against over charge and over discharge Electronic ballast Powder coated carbon steel (white) or stainless steel Stainless steel PHILIPS T8 (supplied with the light fittings) 8W x, 36W x, 8W x 8W x, 36W x, 8W x.3s 4h min (8 min is optional) 3V AC /6Hz M (internal & external earth bolts) IP x. 4mm (L+N+PE) 4 x M x. Plug DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/. Selection table Type/Ordering code Lamp power(w) Weight(kg) Type/Ordering code Lamp power(w) Weight(kg) BAY-8 x XJ 8 x 4. BAY-36 x LJ 36 x.3 BAY-8 x LJ 8 x 4.6 BAY-8 x XJ 8 x. BAY-36 x XJ 36 x. BAY-8 x LJ 8 x.3 Note: Products above include all the mounting accessories listed in Mounting Accessories & Spare Parts Table (see P/4~). Dimension drawings (all dimensions in mm) - subject to alteration 7(8W) 8(36W) 487(8W) 9(8W) 3(36W) 84(8W) BAY- x J / General Catalogue..

4 Light Fittings for Fluorescent Lamp BAY Series Explosion-proof Light Fittings for Fluorescent Lamp Photometric data (BAY- x, BAY- x J) 8W x photometric data Rated luminous flux:lm; Luminous intensity distribution cd/lm 8W x photometric data Rated luminous flux:lm; Luminous intensity distribution cd/lm W x photometric data Rated luminous flux:lm; Luminous intensity distribution cd/lm 36W x photometric data Rated luminous flux:lm; Luminous intensity distribution cd/lm W x photometric data Rated luminous flux:4lm; Luminous intensity distribution cd/lm 8W x photometric data Rated luminous flux:8lm; Luminous intensity distribution cd/lm We can provide lighting design and data by professional lighting software DIALUX based upon simulated site situation on request. General Catalogue.. /

5 Light Fittings for Fluorescent Lamp BAY Series Explosion-proof Light Fittings for Fluorescent Lamp Technical data Explosion-proof LED light fittings for fluorescent lamp BAY-LED x Explosion protection Gas explosion protection Dust explosion protection Certificates Conformity to standards Material Enclosure Glass tube Power controller Wire guard (optional) Exposed fastener Lamp Lamp specification Lamp power (W) Rated voltage Earthing protection Degree of protection Ambient temperature Terminal Mounting Cable entries Single lamp Dual lamp Cable gland II G Ex d IIC T6 Gb II D Ex t IIIC T8 Db IP66 LCIE ATEX 3X; FM (USA); GOST.R (Russia); IECEx EN 679-: 9, EN 679-: 7, EN 679-3: 9 IEC 679-: 7, IEC 679-: 7, IEC 679-3: 8 Copper-free aluminium, powder coated external surface, yellow (RAL). Toughened glass, stands 4J impact. Wide voltage input, CC-CV (constant current - constant voltage) output, powe r factor.98, with function of distributed current, constant current, surge-proof and antielectromagnetic interference, and protection against overcurrent, open circuit, and short circuit. Powder coated carbon steel (white) or stainless steel Stainless steel CREE plural white LED modules (supplied with the light fittings) 9W x, 9W x, 8W x, 8W x 6V AC /6Hz M (internal & external earth bolts) IP x. 4mm (L+N+PE) Ceiling type, pole type 3 x M x. Plug 4 x M x. Plug DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/. Selection table Type/Ordering code Lamp power(w) Weight(kg) Type/Ordering code Lamp power(w) Weight(kg) BAY-LED 9 x X 9 x. BAY-LED 8 x X 8 x 8.3 BAY-LED 9 x L 9 x.9 BAY-LED 8 x L 8 x 8.3 BAY-LED 9 x X 9 x 9.8 BAY-LED 8 x X 8 x.7 BAY-LED 9 x L 9 x. BAY-LED 8 x L 8 x 6.4 Note: Products above include all the mounting accessories listed in Mounting Accessories & Spare Parts Table (see P/4~). Dimension drawings (all dimensions in mm) - subject to alteration BAY-LED x BAY-LED x / General Catalogue..

6 Light Fittings for Fluorescent Lamp BAY Series Explosion-proof Light Fittings for Fluorescent Lamp Comparison between LED fluorescent lamp and T8 standard fluorescent lamp Name Rated power (W) Working current (A) Power factor (cos ) Effective luminous flux (lm) Service life (h) Standard fluorescent lamp 36W 36.7/V.9 3 LED fluorescent lamp 8.96/V.98 6 Energy-saving effect Similar luminous flux, electricity saved by over %, LED lamp service life extended by 4 times, less maintenance expense, and less electric energy loss. Elaboration of plural white LED modules, unidirectional illumination, soft and balanced light, luminous efficiency>9lm/w, high colour rendering, long service life (h), environmental protection. Photometric data (BAY-LED x ) 9W x photometric data Rated luminous flux:8lm; The data from CREE lamp; Luminous intensity distribution cd/lm 9W x photometric data Rated luminous flux:6lm; The data from CREE lamp; Luminous intensity distribution cd/lm W x photometric data Rated luminous flux:6lm; The data from CREE lamp; Luminous intensity distribution cd/lm 8W x photometric data Rated luminous flux:34lm; The data from CREE lamp; Luminous intensity distribution cd/lm We can provide lighting design and data by professional lighting software DIALUX based upon simulated site situation on request. General Catalogue.. /3

7 Light Fittings for Fluorescent Lamp BAY Series Explosion-proof Light Fittings for Fluorescent Lamp Mounting type for light fittings with single lamp tube (all dimensions in mm) - subject to alteration Installation reference X: ceiling type L: pole type (the pole is provided by user) Mounting type for light fittings with dual lamp tube (all dimensions in mm) - subject to alteration Installation reference X: ceiling type L: pole type (the pole is provided by user) X: ceiling type (for: BAY- XJ) L: pole type (the pole is provided by user)(for: BAY- LJ) (8W) 8(36W) 487(8W) 7(8W) 8(36W) 487(8W) /4 General Catalogue..

8 Light Fittings for Fluorescent Lamp BAY Series Explosion-proof Light Fittings for Fluorescent Lamp Mounting accessories and spare parts table (light fittings with single lamp tube) Supplied according to the mounting type Mounting type Name Accessories Qty Illustration Ordering code Weight (kg) X: ceiling type.connector SX.4.Steel wire rope (with hook) Length:.7m (8W),.3m (36W),.6m (8W) SX.3~..G /4 Pipe clamp L: pole type Connector Same as ceiling type SX.4.Steel wire rope (with hook) Same as ceiling type SX.3~. Note: Accessories not in the table shall be supplied by user. Mounting accessories and spare parts table (light fittings with dual lamp tube) Supplied according to the mounting type Mounting type Accessories Name Qty Illustration Ordering code Weight (kg) Connector SX.4 X: ceiling type.steel wire rope (with hook) Length:.7m (8W),.3m (36W),.6m (8W) SX.3. DX3.3.G /4 Pipe clamp L: pole type Connector Same as ceiling type SX.4.Steel wire rope (with hook) Same as ceiling type Same as ceiling type Note: Accessories not in the table shall be supplied by user. SX DX General Catalogue.. /

Lighting Technology. Zones 2; 21&22. Light Fittings for Fluorescent Lamp. BnY81 Series Explosion-proof Light Fittings for Fluorescent Lamp

Lighting Technology. Zones 2; 21&22. Light Fittings for Fluorescent Lamp. BnY81 Series Explosion-proof Light Fittings for Fluorescent Lamp Lighting Technology Light Fittings for Fluorescent BnY81 Series Explosion-proof Light Fittings for Fluorescent Catalogue number logic BnY81- x J: Emergency lighting (optional) X: ceiling type G: pendant

More information

Signal Beacon - LED Series 6162

Signal Beacon - LED Series 6162 www.stahl.de > Versions rotating mirror beacon rotating beacon beacon with double flash (9 + 5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seawater resistant aluminium enclosure

More information

Sicherheit, auf die Sie sich verlassen können

Sicherheit, auf die Sie sich verlassen können Explosion protected linear light fittings SERIES Sicherheit, auf die Sie sich verlassen können LL 48 Ex Linear LED Explosion protected linear light fitting with LED technique Linear light fitting with

More information

CROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights

CROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights CEAG Products Explosion protected floodlights CROUSE-HINDS SERIES PXLED - Power Floodlight Series for Hazardous Areas Explosion-protected LED floodlight series for Zone 1, 2, 21 and 22 Ex-Floodlight PXLED

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

Sicherheit, auf die Sie sich verlassen können

Sicherheit, auf die Sie sich verlassen können CEAG Products Ex-emergency lighting CROUSE-HINDS SERIES Sicherheit, auf die Sie sich verlassen können Explosion protected safety luminaire for Zone 1/2 und 21/22 Explosion protected safety luminaire Zone

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No 9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used

More information

Binary Output without Power Supply Series 9176

Binary Output without Power Supply Series 9176 Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output

More information

Sicherheit, auf die Sie sich verlassen können

Sicherheit, auf die Sie sich verlassen können Explosion protected linear light fittings Sicherheit, auf die Sie sich verlassen können nllk LED Ex-Linear LED Light Fittings for Zone 2/22 nllk Ex-Linear Light Fitting Linear Light Fitting with LED Tubes

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

CEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations. EATON 2.4.1

CEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations.  EATON 2.4.1 CEAG Products Main Catalogue Part : Chapter... Ex-Control units and control stations www.crouse-hinds.de EATON.. .. EATON www.crouse-hinds.de Ex-Control units and control stations Table of contents. GHG

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General

More information

Sicherheit, auf die Sie sich verlassen können

Sicherheit, auf die Sie sich verlassen können Explosion protected linear light fittings Sicherheit, auf die Sie sich verlassen können nllk LED Ex-Linear LED Light Fittings for Zone 2/22 nllk LED / nllk V-CG-S LED DALI Ex-Linear Light Fittings Linear

More information

SYSTEMS AND PARTS EARTHING CONTROL: S604 & S804. Background. Product. Functioning SYSTEMS AND PARTS - EARTHING CONTROL

SYSTEMS AND PARTS EARTHING CONTROL: S604 & S804. Background. Product. Functioning SYSTEMS AND PARTS - EARTHING CONTROL StuvEx NV (Belgium) EARTHING CONTROL: S604 & S804 Background Static electricity is a frequent source of ignition An electrostatic charge can be generated while handling conductive liquids or powders. This

More information

Motor Protection Circuit Breaker Series 8146/5-V27

Motor Protection Circuit Breaker Series 8146/5-V27 www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >

More information

Fieldbus Isolating Repeater Series 9185/11

Fieldbus Isolating Repeater Series 9185/11 www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,

More information

Actuators Series 8602/3

Actuators Series 8602/3 > Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

Isolators A3/1.

Isolators A3/1. > Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]

More information

Sicherheit, auf die Sie sich verlassen können

Sicherheit, auf die Sie sich verlassen können Explosion protected linear light fittings CROUSE-HINDS SERIES Sicherheit, auf die Sie sich verlassen können Ex-Linear LED Light Fittings for Zone 2/22 Ex-Linear LED Light Fittings Linear LED Light Fittings

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

Multiturn absolute encoder

Multiturn absolute encoder 0102 Model Number SYNCHRON SERIELLES INTERFACE Features Up to 30 Bit multiturn ATEX approval IECEx approval Flameproof enclosure Removable connection cap Galvanically isolated RS 22 interface Description

More information

iant101 Zone 1 Omni Directional Antenna

iant101 Zone 1 Omni Directional Antenna iant101 Zone 1 Omni Directional Antenna External Antenna offering increased flexibility for positioning and greatly enhanced RF Propagation. ATEX Ex t IIIC T85 C Db IECEx Ex t IIIC T85 C Db -40 C to 60

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0) DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features C16A 100/200/400 t Self-centering pendulum lead cells Special features - Self restoring function - Nominal (rated) loads: 100 t, 200t and 400t - Simple installation - Rust resistant materials, laser welded,

More information

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471 > 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels

More information

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.* Features Assembly Cable gland series for shielded EMC cables Brass nickel-plated or stainless steel AISI 316 Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d, Ex e and Ex tb Metric and NPT

More information

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time

More information

Local control stations for Zone 1 and Zone 21. Features. Description

Local control stations for Zone 1 and Zone 21. Features. Description Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning

More information

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series > Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:

More information

Binary Output Series 9175

Binary Output Series 9175 Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 7 Applications Process engineering Plant construction General

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation

More information

Digital I/O Coupler (4-wire) Series 9413/21

Digital I/O Coupler (4-wire) Series 9413/21 Digital /O Coupler (4wire) > The digital /O coupler is used to connect 8 intrinsically safe contacts or proximity initiators and 4 intrinsically safe solenoid valves to a FOUNDATON TM fieldbus H1. > Galvanic

More information

Position switches FM series

Position switches FM series B Position switches FM series Selection diagram 0 08 0 A A 0 A 0 external rubber gasket external rubber gasket external rubber gasket external rubber gasket 69 stainless steel round rod square rod fiber

More information

Rudder or propeller angular position transmitter KINAX WT720

Rudder or propeller angular position transmitter KINAX WT720 Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to

More information

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/. Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

The Rosemount 848T Wireless Temperature Transmitter

The Rosemount 848T Wireless Temperature Transmitter Rosemount 88T Family February 0 The Rosemount 88T Wireless Temperature Transmitter The Rosemount 88T is the premier choice for Wireless High Density measurements. Four independently configurable inputs

More information

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS Highlights in this presentation. 1. Have received BIS Approval for 62, 66, 67, 67L, 71 & 71L. 2. CCOE for the same is under process. 3. UL 1203 Approval

More information

Beamer Floodlight LED IP 65

Beamer Floodlight LED IP 65 3 6666 4 205 3 6666 4 160 283 466663 4666663 336 153 666666 36664 LED 0q p C IP 65 Graphit m LED 36W 3780lm 3000K warm white Switchable Version 5 Spherolit lens, wide flood Product description Housing,

More information

GE LED Edgelit Panel. PREMIUM version. GE Lighting DATA SHEET. Product information. Features and Benefits. Application areas

GE LED Edgelit Panel. PREMIUM version. GE Lighting DATA SHEET. Product information. Features and Benefits. Application areas GE Lighting GE LED Edgelit Panel PREMIUM version DATA SHEET IP40 CLASS II Product information GE LED luminaires transform ambient lighting into an exquisite balance of refined appearance and superior efficiency.

More information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5. Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

E LED Lighting BV & Inc. European Office: Tel: +31 (0) , Fax +31 (0) , E mail LEDLighting.com United States Office:

E LED Lighting BV & Inc. European Office: Tel: +31 (0) , Fax +31 (0) , E mail LEDLighting.com United States Office: HIGH POWER LED LIGHTS LED Flood Lights LED Floodlights operate efficiently and save power but also reduce maintenance and service costs as a result of their long life. Conventional floodlights require

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Temperature OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 11 Applications Machine building, plant and vessel construction

More information

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - # Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db

More information

BExCS / BExDCS110-05

BExCS / BExDCS110-05 BExCS11005 / BExDCS11005 Combination Alarm The flameproof BExCS11005 combination alarm sounders and Xenon beacons are suitable for Zone 1 & Zone 2 applications and the BExDCS11005 versions also for Zone

More information

LED LL DP CD WW CS CF AC CG. Wall Washer CB LC FO EL

LED LL DP CD WW CS CF AC CG. Wall Washer CB LC FO EL LED Projectors LED LL DP CD WW CS CF AC CG Wall Washer The wallwasher series offers ideal lighting solutions for indoor and outdoor venues. These luminaires are utilised for the purpose of illuminating

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high

More information

SKILL. Wall mounted. Bollard

SKILL. Wall mounted. Bollard SKILL Wall mounted Bollard Skill square 270mm www.simes.it/skill 51 SKILL lighting for surface or flush wall mounting Die-cast EN AB-47100 aluminium (low copper content) housing with high corrosion resistance.

More information

Installation & Operating Manual. iwap202

Installation & Operating Manual. iwap202 Installation & Operating Manual iwap202 This page is intentionally left blank. Document Number 409345 (based on 407655) (See Last Page for Revision Details) For warranty information, refer to Terms and

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Fisher 4200 Series Electronic Position Transmitters

Fisher 4200 Series Electronic Position Transmitters Product Bulletin D200357012 4200 Series Transmitter Fisher 4200 Series Electronic Position Transmitters Fisher 4200 Series electronic position transmitters (figure 1 and 2) combine field-proven electronic

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers Series 9001 Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving

More information

Description of equipment

Description of equipment Applicant: Electrical Apparatus: KROHNE Messtechnik GmbH & Co. KG Level Radar BM 70M-Ex Description of equipment The Types BM 70M-Ex Level Radar gauges serve to continuously measure the product level in

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

WS12EX Position Sensor with Analog output Dust explosion-proof

WS12EX Position Sensor with Analog output Dust explosion-proof Sensor for Hostile Environments Class IP67 Measurement Range: 0... 100 mm to 0... 3000 mm With Analog Output Dust Ex proof, category 3, zone 22 II 3D EEx T80 C IP67 Specifications Outputs Material Resolution

More information

Safety switches with slotted hole lever

Safety switches with slotted hole lever Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Reference number Dimensions Lamp Light colour

Reference number Dimensions Lamp Light colour 1 LED STRIPS PRO up to 152 lm/w LESS IS MORE FLEX: LED strip PRO Type of Protection: IP 00 IP 66 CVD Protection Class: III Flexible LED strip on roller (5 m). Mounting using 3M Thermal double-sided tape.

More information

FM series position switches

FM series position switches FM series position switches Selection diagram 0 08 0 A A 0 A 0 External rubber gasket External rubber gasket External rubber gasket External rubber gasket 0 69 Round rod, stainless steel Square rod Glass

More information

ETC. Source Four Mini LED. Source Four Mini Series GENERAL INFORMATION ORDERING INFORMATION. Source Four CE Mini LED / Mini LED Gallery (Body Only)

ETC. Source Four Mini LED. Source Four Mini Series GENERAL INFORMATION ORDERING INFORMATION. Source Four CE Mini LED / Mini LED Gallery (Body Only) GENERAL INFORMATION The Source Four CE Mini LED can go where no full-sized Source Four has gone before. ETC s 12W features the same crisp optics, user-friendly functionality and sleek look of the legendary

More information

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For water and wastewater Model LW-1 Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and

More information

RGB Cuttable every 100 mm. 60 LEDs per meter (LED Pitch 16,7 mm). Constant luminous flux by means of transistor

RGB Cuttable every 100 mm. 60 LEDs per meter (LED Pitch 16,7 mm). Constant luminous flux by means of transistor LED STRIPS 1 LESS IS MORE FLEX: LED strip ECO Type of Protection: IP 00 IP 66 CVD Protection Class: III Flexible LED strip on roller (5 m). Mounting using 3M Thermal double-sided tape. Voltage 24 V. ECO

More information

Power supply. Calibration. Surface finishing. Seal. Process connection

Power supply. Calibration. Surface finishing. Seal. Process connection Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst

More information

Baymaster HL LED Luminaire High Bay for Hazardous Locations

Baymaster HL LED Luminaire High Bay for Hazardous Locations Class I, Division, Group A, B, C, D Class I, Zone, Group IIC Class II, Division &, Group E, F, G Zone and Group IIIC Zone Group IIIB Applications Enclosed and gasketed fixtures suitable for use in: A wide

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

Submersible pressure sensor For oils and fuels Model LF-1

Submersible pressure sensor For oils and fuels Model LF-1 Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

Material High-quality aluminium alloy High-quality aluminium alloy

Material High-quality aluminium alloy High-quality aluminium alloy Aluminium enclosures The -Series of enclosures offers excellent resistance in industrial and transport environments. They are ideal for a wide series of applications, including configurations with terminals,

More information

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement

More information

Operating Manual. isolate501

Operating Manual. isolate501 Operating Manual isolate501 Document Number 413569 (See Last Page for Revision Details). Copyright Extronics Ltd, 2015 Page 2 of 21 Contents 1 Introduction... 4 2 Safety Information and Notes... 5 2.1

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Remote I/O. 74 Remote I/O. Remote I/O System

Remote I/O. 74 Remote I/O. Remote I/O System System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU

More information

Rosemount 648 Wireless Temperature Transmitter

Rosemount 648 Wireless Temperature Transmitter Rosemount 648 Wireless Temperature Transmitter with Rosemount X-well Technology Product Data Sheet July 2016 00813-0100-4648 Rev GD Rosemount X-well Technology provides accurate process temperature without

More information

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/ 3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

TECHNICAL DIVISION GALILEO 1 IN Rev. MAR-17

TECHNICAL DIVISION GALILEO 1 IN Rev. MAR-17 Applications Optic Insulation class Protection degree LED Modules Tilt Angle Dimensions Weight Mounting Gear tray Operating temp. Main reference standards GALILEO 1 IN MAIN CHARACTERISTICS Indoor lighting

More information

Simply great LED Switch now to great quality LED at a great price. Product Range. Detailed Photos

Simply great LED Switch now to great quality LED at a great price. Product Range. Detailed Photos Simply great LED Switch now to great quality LED at a great price The Ledinaire range contains a selection of popular off-the-shelf LED luminaires that comes with the Philips high quality levels at a competitive

More information

2-way pilot operated solenoid valves for water, hot water and steam

2-way pilot operated solenoid valves for water, hot water and steam 2-way pilot operated solenoid valves for water, hot water and steam Catalogue 8658/GB NEW Also available with ATEX Explosion-proof electrical parts Technical specifications General description Applications

More information

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro Pneumatic Transducer Product Bulletin D101374X012 646 Transducer Fisher 646 Electro Pneumatic Transducer The Fisher 646 electro pneumatic transducer, shown in figure 1, uses a converter module that converts a 4 to 20 milliampere

More information