Instromet Weather Systems Ltd. Climatica Weather Station User Guide

Size: px
Start display at page:

Download "Instromet Weather Systems Ltd. Climatica Weather Station User Guide"

Transcription

1 Instromet Weather Systems Ltd Climatica Weather Station User Guide

2 Contents: 1) Introduction 2) Specifications 3) Package Contents 4) Installation 5) Operating instructions 6) Multi Weather display Features 7) Trouble shooting guide Introduction. Welcome to your new Climatica weather station. This is Instromet s most feature packed unit to date and gives the operator access to both weather information not previously found in any Instromet weather station product and also incorporates auto sensor detection technology which makes this the most versatile Instromet weather station yet with the ability to display any of the Instromet weather sensors. This product handbook only covers the installation and use of the standard supplied system. Details regarding the installation of extra sensors can be found either via the web site or with the enclosed leaflet with each sensor. System Specifications. Display Unit size: 178mm High, 390mm Wide, & 68mm Deep Display Parameters: Wind Direction: Analogue read-out 4 cardinal points sub-divided into 5 degree increments, electronically damped. Accuracy: ± 10 degrees, resolution > 10 degrees Wind speed: Analogue read-out with gust indicator pointer, calibrated 0-90 mph, 0-80 knots and Beaufort scale. Alternative kph and metres/second scales are available Accuracy: ± 5% or 3 knots Barometer: Analogue read-out with set pointer, range mbar (28-31 inches Hg) Temperature: digital read-out in degrees F or C Range - 40 to + 50 C (- 40 to F), resolution 0.1 C Clock: 24hr time with day/month/year date

3 System Contents: Upon opening, the below items should be present: 1) Climatica Display 2) Sensor Junction box 3) 5m Display cable 4) Wind / Temp Sensor with 25m of cable ( /01 ) 5) Plug in power supply 6) Compass The below are optional extras for system expansion: 1) Wet and Dry Sensor ( /01 ) 2) Humidity Sensor ( /01 ) 3) Rainfall sensor ( /01 ) 4) Sunshine sensor ( /02 ) 5) Temperature sensor ( /01 ) 6) Datalogger inc PC software ( ) 7) Electronic Barometer PCB (Datalogger use only) ( /02 ) 8) Battery back up module ( ) 9) 2m mast kit ( ) 10) 1m mast kit ( ) The above options are available separately from Instromet sales: sales@instromet.co.uk Tel: (0)

4 Installation instructions: Before getting started a small flat bladed screw driver will be required for adjusting the various screw terminal connections. Upon receipt the sensor PCB will be packaged within an anti static bag, and this will need to be removed. The PCB can then be slotted into the box and the two way plug on the trailing wire from the PSU socket will need to be connected to CON4 on the sensor PCB. The Diagram on the adjacent page shows details for attaching the sensors to the sensor box PCB. Each sensor is supplied with 25m of cable as standard and each core of the cable is colour coded to match the sensor PCB and the sensor itself. This being the case each connection made needs to be matched colour to colour at both ends of the cable, this ensures a simple to follow installation which can be done by anyone. The diagram shows the basic wind sensor being utilized with a four core cable. But the standard supply of wind sensor with the Climatica display is our temperature version with a six core cable. The extra green and white wires for the temperature need to be connected into the Air Temp connections. The wind sensor should ideally be mounted on a 25-50mm diameter pole and as high as possible and away from any thing which could obstruct the flow of wind hitting the cups or anything which could cause wind turbulence as this to could lead to incorrect readings. Other wise the only other setup for the wind sensor is to ensure its pointing North using the compass provided. For the installation of extra sensors, please see separate installation documents enclosed with each sensor. Once the sensors are connected to the sensor PCB, The display cable will also need connecting. Again this is colour coded to match the sensor PCB. The plug end of the cable will need to be connected to the back of the display and can only be fitted in one direction. The display itself can either be shelf mounted or wall mounted using the Key hole slots in its back panel. The Key hole slot centres are 292mm apart.

5 con4

6 Operating Instructions: Once the display is connected and before powering up for the first time the Dip switch for the internal back up battery on the rear of the display needs to be set to on for the display to be able to store its memory in the event of a power failure. This can be found in the cut out slot next to the display cable position and is marked as the central switch on the rear panel label. This is a rechargeable battery which is charged by the display and so should not need attention. Regarding the other Dip switches only the sounder on/off and Humitter / Wet & Dry switches may need to be adjusted, the other two can be left where they are factory set. The mechanical Barometer will need to be set locally as this is only set to its mid position when assembled in the factory. Its adjustment point is next to the rear panel label through the circular hole in the back panel. Gently rotate the adjustment screw clockwise or anti clockwise to reach the desired barometric pressure. Local pressure readings can be obtained from the MetOffice web site at the below address: When the display is initially powered the displays back lighting will come on and the multi weather display will activate. Also the dials for the wind speed and direction should also start to move as long as the wind sensor is connected. Adjusting the multi weather display is done via the five end panel buttons: 1) Up - A 2) Down - B 3) Enter - C 4) Exit - D 5) Scroll The top four buttons are used to navigate the display while the bottom Scroll button is to enable the display scroll function where by it will cycle each relevant screen automatically. With the Scroll switch off the Up and Down buttons can be used to manually change screen. The diagram gives details on each screen plus its relevant button presses for each function. Please be aware that the display will only show the sensors connected. For example if no rain sensor is connected, no rain sensor display will be available. The clock will need to be set first to enable correct time keeping and also for the correct months to be displayed on the Sun & Rain screens.

7 Wind Speed Button Button W I N D S P E E D - M P H C A = R E S E T R E A D I N G S C A = X 2 M O D E ( O F F ) G U S T = 3 0 A V E R A G E = 2 5 B = U N I T S ( M P H ) C = + B = S E T G U S T A L A R M Button Press B = A = I N C B = D E C D = O K M P H Wind Direction W I N D D I R E C T I O N C A = R E S E T R E A D I N G S P R E V A I L I N G = N W N Temp1 A I R T E M P = ±. C A = R E S E T R E A D I N G S C A = I N C B = D E C D = O K M I N = ±. M A X = ±. B = U N I T S ( C ) C = C A L C D I S P L A Y C Temp2 T E M P = ±. C A = R E S E T R E A D I N G S B A = U P B = D N C = N X T D = O K M I N = ±. M A X = ±. B = E D I T T E X T C = C A L C A = I N C B = D E C D = O K C D I S P L A Y C Rain R A I N T O D A Y =. m m C A = R E S E T R E A D I N G S M A Y =. A P R =. B = U N I T S ( M M ) Sunshine Hours S U N T O D A Y =. H R S C A = R E S E T R E A D I N G S M A Y =. A P R =. Humidity H U M I D I T Y N O W =. % C A = R E S E T R E A D I N G S M I N =. M A X =. Clock T I M E =.. C A = U P B = D N C = N X T D = O K D A T E = 2 0 / M A Y / H R : M N : S C D Y / M O N / = U S E R D E F I N E D = S E N S O R R E A D I N G = D E R I V E D F R O M C L O C K

8 Multi Weather Display features: The Multi Weather Display (MWD) fitted to the Climatica display has an auto detect feature which automatically displays details about any Instromet sensor which is connected to it. Below are details regarding each sensors display attributes / features: Wind Speed: Wind Direction: Air Temp: Aux Temp: Rainfall: Sunshine hours: MPH, MPS, & KPH selectable ( MWD only) Maximum gust measured Last 10 minute wind speed average X2 function for high wind events Programmable gust alarm Daily Prevailing wind direction Current temperature C / F selectable Min / Max readings On screen calibration Current temperature C / F (select on air temp screen) Min / Max readings On screen calibration User definable heading up to 8 characters Daily rain reading to 0.01mm resolution mm / inch selectable previous and current monthly totals Daily rain reading to 0.01 hour resolution previous and current monthly totals Humidity: Current humidity reading - % Min / Max readings Humitter or Wet & Dry sensor selectable Built in Dew point tables for Wet & Dry calculation. Clock: 24Hr Date day / month / year Note: When using a Wet & Dry bulb the Aux temperature display is no longer available as the display uses this reading for the Humidity calculation. If a second temperature is required along with humidity then it is necessary to use the Instromet Humitter instead of the Wet & Dry bulb.

9 Trouble shooting guide: Despite careful consideration when installing the system, if a feature does not operate as expected then please consult the notes below: Display not working: Check if the back lights are on if not then no power is getting to the display. If they are try powering down the system and then powering up again after 30 seconds. Check con4 on the sensor PCB has been connected to the PSU socket via the trailing lead. Check the colour coded connections for the Display cable are correct and that the plug end is firmly connected to the display. Check the PSU is actually connected to the wall outlet and switched on. Display is on but no sensor readings being displayed: Check the individual sensor cables to ensure they are connected firmly both in the sensor box and at the sensor. Ensure the sensor cables are colour coded correctly. Power the system down for 30 seconds before re-connecting the power to see if the sensor is then recognised. Wind direction incorrect: Check sensor arm orientation is pointing North. If all else fails call the service department on ++44 (0) or return the system to us for testing or replacement. Disclaimer Instromet products are designed to monitor current and previous weather conditions for domestic use and should not be considered as predictive weather forecasting equipment. Contact your regional Met Office centre if you need weather forecasting data ( Our products are tested in-house for operation and functionality but have not been independently tested by a UKAS accredited laboratory. As part of our ongoing policy to improve the design and specification of our products, we reserve the right to change any detail given without prior notice. Instromet Weather Systems Ltd shall not be responsible for any liability or loss of any nature which may result from the use of any information provided in technical literature.

10 Notes: Enter the system Serial number here for future reference: Enter the code here shown on the back of the display below the serial number:

11 Notes:

12 Instromet Weather Systems Ltd. 10b, Lyngate Industrial Estate, North Walsham, Norfolk, NR28 0AJ. Web: Tel: ++44 (0) Fax: ++ (0) Document part number:

Instromet Wireless Wind Sensor Interface Installation Instructions

Instromet Wireless Wind Sensor Interface Installation Instructions Instromet Wireless Wind Sensor Interface Installation Instructions Wind speed and direction only Introduction: These instructions cover the installation and operation of Instromet Weather Systems wireless

More information

Pro Weather Station Model: WMR86 / WMR86A

Pro Weather Station Model: WMR86 / WMR86A Pro Weather Station Model: WMR8 / WMR8A USER MANUAL CONTTS Introduction... Packaging Contents... Base Station... Wind Sensor... Temperature & Humidity Sensor... Rain Gauge... Accessories - Sensors... Overview...

More information

GDR750DAB GDR730DABSOL

GDR750DAB GDR730DABSOL The DAB+ RECHARGEABLE & SOLAR DIGITAL RADIO GDR750DAB GDR730DABSOL The Gold Technical Support Line: 1902 215 259 Personal Product Support (Charges will apply at $2.95 per minute) 1 Introduction Thank you

More information

Package Contents: Features: Carefully unpack and remove the contents:

Package Contents: Features: Carefully unpack and remove the contents: 315911 Package Contents: Carefully unpack and remove the contents: 1x weather station main unit All in one sensor with solar panel 1x stainless steel mast Stainless steel accessory for fixing. 1x adapter

More information

TABLE OF CONTENTS BATTERIES. S84107 FAQS... 1 Batteries... 1 Weather Station Factory Restart... 2 Battery Change Power requirements...

TABLE OF CONTENTS BATTERIES. S84107 FAQS... 1 Batteries... 1 Weather Station Factory Restart... 2 Battery Change Power requirements... S84107 FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader TABLE

More information

TPW899. Package Contents. Technical Details

TPW899. Package Contents. Technical Details . TPW899 Thank you for purchasing this Ytora device. Please read these operating instructions carefully to familarize yourself with the features and modes of operation before using the instrument. Package

More information

Wireless Pressure Station

Wireless Pressure Station Wireless Pressure Station FORECAST RELATIVE PRESSURE PRESSURE HISTORY inhg -24h -18h -12h -9h- 6h -3h0 h INDOOR For online video support: http://bit.ly/laxtechtalk Model: 308-1417 DC: 111517 Table of Contents

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, F: (979) 690-0440 Barometric Pressure: WE100 Solar Radiation: WE300

More information

Telemetrie-Messtechnik Schnorrenberg

Telemetrie-Messtechnik Schnorrenberg Telemetrie-Messtechnik Schnorrenberg CT16-Wheel User manual TMS Telemetrie-Messtechnik Schnorrenberg Dipl.-Ing. Werner Schnorrenberg Habichtweg 30, D-51429 Bergisch Gladbach, Tel: 02204-9815-52, Fax: 02204-9815-53,

More information

Wireless Pressure Station with Backlight

Wireless Pressure Station with Backlight Wireless Pressure Station with Backlight FORECAST RELATIVE PRESSURE PRESSURE HISTORY inhg -24h -18h -12h -9h- 6h -3h0 h INDOOR For online video support: http://bit.ly/laxtechtalk Model: 308-1417BL DC:

More information

Logging the Instromet sunshine sensor

Logging the Instromet sunshine sensor Logging the Instromet sunshine sensor Sensor description Instromet are a supplier of weather instruments based in Norfolk, England. Over the past decade or so this simple, reliable, consistent and reasonably-priced

More information

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this compact 868MHz Temperature Station which displays radio controlled time, date, indoor and outdoor

More information

Important safety instructions

Important safety instructions RCR-29 GB Version 1 Important safety instructions VERY IMPORTANT PLEASE READ Sangean suggest that you keep your AC Adapter at least 12 inches away from the radio while listening to the AM Band. Your Sangean

More information

EasyStitch. Instruction and guarantee manual 1 YEAR GUARANTEE

EasyStitch. Instruction and guarantee manual 1 YEAR GUARANTEE EasyStitch Instruction and guarantee manual 1 YEAR GUARANTEE CONTENTS: 1. Machine Parts 2. Accessories 3. Safety Instructions 4. Battery Installation 5. Threading 6. Fitting fabric and sewing 7. Adjusting

More information

Atomic Forecast Station with Moon Phase

Atomic Forecast Station with Moon Phase Atomic Forecast Station with Moon Phase For online video support: http://bit.ly/laxtechtalk Model: S84107 Instruction Manual DC: 080817 Welcome to the La Crosse Technology family! We hope you enjoy your

More information

Halo Umbrella Light. Assembly and Operation Guide

Halo Umbrella Light. Assembly and Operation Guide Halo Umbrella Light Assembly and Operation Guide Thank you for purchasing Treasure Garden s Halo Umbrella Light. Please remove all contents from the package, inspect and review checklist. CAUTION: To reduce

More information

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1 OPERATING INSTRUCTIONS ARE ON PAGE 5 RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1 This Programmable Ravenheat R/F controlled room Thermostat RVHT 2, consists of 2 items: a Mobile Transmitter

More information

S ENSORLINK INSTALLATION MANUAL

S ENSORLINK INSTALLATION MANUAL S ENSORLINK INSTALLATION MANUAL The SensorLink Transmitter (#7610) and SensorLink Receiver (#7611) are designed to work with Davis Instruments Weather Monitor II and the Weather Wizard III to enable wireless

More information

Connect + compatible

Connect + compatible Connect + compatible Looking for a quick setup up guide? There is lots of useful information in this book, but if all you are after is quick set up look for the following headings in this book 1) Setting

More information

KRONOsync Transmitter System Operations Guide

KRONOsync Transmitter System Operations Guide KRONOsync Transmitter 11869 Teale St. Culver City, CA 90230 Tech Support: 888-608-0125 www.innovationwireless.com Thank You for Purchasing the KRONOsync GPS/NTP Wireless Clock System from. We appreciate

More information

User Manual.

User Manual. www.brinno.com User Manual Package Contents 1- BirdWatchCam 2- Mounting unit 3-2 Rubber straps 4- Measuring tape 5- User manual 6-2 GB SD Card 7-4 AA batteries Brinno Incorporated s BirdWatchCam User

More information

Top spin Nr /

Top spin Nr / Top spin Nr. 1840 0000 / 1840 1000 Bedienungsanleitung 21-6680 28052014 / A Made in Germany Ideas for dental technology Top spin Nr. 1840 0000 / 1840 1000 Contents 1. Introduction...2 1.1 Symbols...2 2.

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Barometric Pressure: WE100 Solar Radiation: WE300 Wind Speed: WE550 Wind

More information

INSTALLATION & PROGRAMMING MANUAL PROGRAMMABLE TIMER (MODEL LP-2)

INSTALLATION & PROGRAMMING MANUAL PROGRAMMABLE TIMER (MODEL LP-2) INSTALLATION & PROGRAMMING MANUAL PROGRAMMABLE TIMER (MODEL LP-2) Copyright Lencore Acoustics Corp. All rights reserved. April 2000 CONTENTS Introduction 3 Display 3 Keyboard 4 Installation 4 Set Up 4

More information

Installation Guide Flat Panel Antenna Mounting Kit For

Installation Guide Flat Panel Antenna Mounting Kit For Installation Guide Flat Panel Antenna Mounting Kit For 103670-1 495R Billerica Ave. North Billerica, MA 01862 USA Tel (978)459-8800 fax (978)459-3310 / 8814 Email: sales@radiowaves.com www.radiowaves.com

More information

Important Safety Information

Important Safety Information OWNER'S MANUAL Important Safety Information 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only

More information

PocketLab Weather Getting Started Guide

PocketLab Weather Getting Started Guide Display and Record Sensor Data 1. To record data, press the Record button on the graph screen. The current data will clear and the app will record new sensor data. 2. To stop the data recording, press

More information

VS7550 VUV/UV Mini Spectrograph Operating Manual

VS7550 VUV/UV Mini Spectrograph Operating Manual Document RD 15 11 No: VS7550 VUV/UV Mini Spectrograph Operating Manual VS7550 Operating Manual 1 Table of Contents Table of Contents Overview Specifications Vacuum Interface Software and Drivers Packing

More information

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297 User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth Model

More information

Rotary Fixture M/V/X CLASS LASER SYSTEMS. Installation and Operation Instructions

Rotary Fixture M/V/X CLASS LASER SYSTEMS. Installation and Operation Instructions Rotary Fixture M/V/X CLASS LASER SYSTEMS Installation and Operation Instructions 02/01/2000 Introduction The Rotary Fixture controls in the Printer Driver are used along with the optional Rotary Fixture

More information

Digi-Stop. Installation & Operation

Digi-Stop. Installation & Operation Digi-Stop Installation & Operation WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon

More information

Manual Wind Monitor Instrument Model 6533A

Manual Wind Monitor Instrument Model 6533A Manual Wind Monitor Instrument A Revision History File name / Revision Date Authors & Change Details Checked/ Approved Previous version BX 2004 RS/ JH MS Unidata Manual - 6533 RM Young Wind Instrument

More information

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model 6012-06XR Specifications & Dimensions 2 Theory of Operation 3 System Block Diagram 4 Operator Controls & Connectors 5 Test Connections

More information

Wireless Color Weather Station

Wireless Color Weather Station Wireless Color Weather Station INSTRUCTION MANUAL MODEL: C85845V3 DC: 120518 FIND MANUALS, FAQS, AND MORE UNDER THE SUPPORT TAB HERE: bit.ly/c85845v3 TABLE OF CONTENTS 3. Power Up 3. LCD Features 4. Buttons

More information

ABM International, Inc.

ABM International, Inc. ABM International, Inc. Lightning Stitch required 1 1.0: Parts List head and motor assembly (Qty. 1) Reel stand (Qty. 1) Needle bar frame clamp (Qty. 1) Motor drive (Qty. 1) 2 Cable harness with bracket

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ELECTRONIC COMPASS W/ SERIAL INTERFACE MODEL 32500 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772

More information

V21-WTH FAQS CONTENTS

V21-WTH FAQS CONTENTS V21-WTH FAQS We are weather enthusiasts like you and know proper running equipment is important. These FAQS provide valuable information on setup, positioning, and troubleshooting your station. We recommend

More information

Operating instructions. Radio weather station

Operating instructions. Radio weather station Operating instructions Radio weather station 0334.. Notes regarding the battery Batteries and button cells do not belong in the hands of children. Contact a doctor immediately if a button cell has been

More information

RECLINE: Remote Inclinometer System

RECLINE: Remote Inclinometer System RECLINE: Remote Inclinometer System Recline: rɪˈklʌɪn: verb; to relax and be supported Calibration Procedures Version 2.2 March 2018 Calibration Procedures It is recommended that a service calibration

More information

SUNDIAL Light Dimmer. User's Manual

SUNDIAL Light Dimmer. User's Manual Light Dimmer User's Manual 1. PRECAUTIONS Although fuses at the input and outputs of the controller protect its circuits in case of an overload or overvoltage, we recommend installing an additional protection

More information

Anywhere Weather Kit Model: LW301/LW301U/LW301A. Anywhere Weather Kit Basic Model: LW302/LW302U/LW302A USER MANUAL CONTENTS

Anywhere Weather Kit Model: LW301/LW301U/LW301A. Anywhere Weather Kit Basic Model: LW302/LW302U/LW302A USER MANUAL CONTENTS Anywhere Weather Kit Model: LW0/LW0U/LW0A Anywhere Weather Kit Basic Model: LW0/LW0U/LW0A USER MANUAL CONTENTS Introduction... Packaging Contents... Communications set... Wind sensor... Temperature & humidity

More information

WS-7136U Wireless 433 MHz Temperature Station. Instruction Manual

WS-7136U Wireless 433 MHz Temperature Station. Instruction Manual WS-7136U Wireless 433 MHz Temperature Station Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents 3 Additional Equipment 4 Quick Setup 5-9 Detailed Setup Guide Battery Installation 10-12

More information

WS-7212NU Wireless 433 MHz Weather Station. Instruction Manual

WS-7212NU Wireless 433 MHz Weather Station. Instruction Manual WS-7212NU Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents 3 Additional Equipment 4 Quick Setup Guide 5-9 Function Keys 5 Detailed Set-up Guide 10-15

More information

INTRODUCTION. Bills (loose) Coins (loose, rolled) Using the Cashmaster you will notice some changes in the way you work:

INTRODUCTION. Bills (loose) Coins (loose, rolled) Using the Cashmaster you will notice some changes in the way you work: User Manual CONTENTS Introduction.............. 1 Box items and guidelines... 2 Charging.. 2 Unpacking... 3 Warning...... 3 The main parts of the Cashmaster... 4 Keys and display The keypad......... 5

More information

Quolis 5000 Light INSTALLATION AND OPERATION INSTRUCTIONS. Model AL-820 IMPORTANT

Quolis 5000 Light INSTALLATION AND OPERATION INSTRUCTIONS. Model AL-820 IMPORTANT Quolis 5000 Light Model AL-80 INSTALLATION AND OPERATION INSTRUCTIONS IMPORTANT After installation is completed, check all the bolts, screws and fasteners to confirm that they are securely fastened. R

More information

ENGLISH PORTUGUÊS NEDERLANDS DAB200

ENGLISH PORTUGUÊS NEDERLANDS DAB200 DEUTSCH ENGLISH FRANÇAIS NEDERLANDS ESPAÑOL PORTUGUÊS NORSK DAB200 Contents Introduction..... 2 What is DAB + Digital Radio?.... 2 Setting up..... 3 Backlit display.... 4 Using headphones...... 4 Your

More information

AC MASTER Switch mode sine wave inverter

AC MASTER Switch mode sine wave inverter USERS MANUAL / GEBRUIKERSHANDLEIDING / BETRIEBSANLEITING MANUEL D UTILISATION / MANUAL DE UTILIZACION / INSTRUZIONI PER L USO AC MASTER Switch mode sine wave inverter Models 12/200, 12/350, 24/200 & 24/350-230V

More information

NEW TOUGHEST WIND SENSORS THE WORLD S 1:2

NEW TOUGHEST WIND SENSORS THE WORLD S  1:2 F T 74 2 D ATA S H E E T NEW S U R FA C E M O U N T D E S I G N E D F O R I N T E G R AT I O N THE WORLD S TOUGHEST WIND SENSORS WWW.FTTECHNOLOGIES.COM 1:2 PROVEN IT LOOKS DIFFERENT BECAUSE IT IS DIFFERENT

More information

Aqua-Gen 3BR INSTRUCTIONS

Aqua-Gen 3BR INSTRUCTIONS Aqua-Gen 3BR INSTRUCTIONS INSTALLATION INSTRUCTIONS CONTROLLER: Find a suitable location to mount the control box* radio note. The controller must be installed out of direct weather and no closer than

More information

User s Manual. F2 Calculator. A metering component for thermal energy applications

User s Manual. F2 Calculator. A metering component for thermal energy applications User s Manual F2 Calculator A metering component for thermal energy applications Rev 08.24.2007 1 Installation 1.1 At delivery F2 calculators are delivered in the Transport Mode. Only the clock is active

More information

TOYOTA COROLLA EC REARVIEW MIRROR Section I Installation Preparation

TOYOTA COROLLA EC REARVIEW MIRROR Section I Installation Preparation Section I Installation Preparation Part Number: PT374-02030 Section I Installation Preparation Kit Contents Item # Quantity Reqd. Description 1 1 AD Mirror Assembly w/compass & Maplights 2 1 Hardware Bag

More information

PHALCON 2000 Installation Guide

PHALCON 2000 Installation Guide PHALCON 2000 Installation Guide PHAROS MARINE 1999 The copyright in this document is vested in AB Pharos Marine Ltd. and the document is issued in confidence for the purpose only for which it is supplied.

More information

18 Indoor/Outdoor Atomic Wall Clock

18 Indoor/Outdoor Atomic Wall Clock Model: WT-3181 Instruction Manual DC: 062915 18 Indoor/Outdoor Atomic Wall Clock Get Started Step 1: Remove the round battery cover from the back of the clock. Step 2: Insert 1 fresh AA, LR6 1.5 volt ALKALINE

More information

Field Service Procedure PCU Kit, XX97, XX97A & XX00

Field Service Procedure PCU Kit, XX97, XX97A & XX00 1. Brief Summary: Troubleshooting document for diagnosing a fault with and replacing the PCU assembly on the XX97, XX97A and XX00 series antennas. 2. Checklist: Verify Initialization N0 Parameter Pedestal

More information

Temp / RH / CO 2 Hand-Held Meter

Temp / RH / CO 2 Hand-Held Meter Temp / RH / CO 2 Hand-Held Meter PRODUCT MANUAL Item # 3440 CONTENTS Specifications 2 Battery 3 LCD Display 3 Keypad 3 Operation 4 Troubleshooting 7 Warranty 8 CE Declaration of Conformity 8 Thank you

More information

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual USL300 SNOW DEPTH SENSOR Revision 1.1.2 User Manual 1 Table of Contents 1. Introduction... 3 2. Operation... 3 2.1. Electrostatic Transducer... 4 2.2. SL300 Analog Board... 4 2.3. SL300 Digital Circuit

More information

Procedure, Field Replacement, PCU Kit, XX04

Procedure, Field Replacement, PCU Kit, XX04 1. Brief Summary: Troubleshooting document for diagnosing a fault with and replacing the XX04 series PCU assembly. 2. Checklist: Verify Initialization N0 Parameter Pedestal Error Test Motor 3. Theory of

More information

Procedure, Field Replacement, PCU Kit, 6003A/6004, 2406 & 4003A

Procedure, Field Replacement, PCU Kit, 6003A/6004, 2406 & 4003A 1. Brief Summary: Troubleshooting document for diagnosing a fault with and replacing the PCU assembly on the 6003A/6004, 2406 & 4003A series antennas. 2. Checklist: Verify Initialization N0 Parameter Pedestal

More information

QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS

QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS 1.0 DESIGNATIONS T2 AND X2 1. Removable Reflector, two positions Normal and Wide angle. 2. Flash-tube 2A. Modeling Lamp (for Model X2 only) 3. Bounce Head,

More information

DIVERSE MAGMETER MF500M MAGNETITE METER USER MANUAL. CAMBRIDGE ENGLAND CB22 5EW.

DIVERSE MAGMETER MF500M MAGNETITE METER USER MANUAL.     CAMBRIDGE ENGLAND CB22 5EW. MAGMETER MF500M MAGNETITE METER DIVERSE USER MANUAL CAMBRIDGE ENGLAND CB22 5EW Page 1 Contents INTRODUCTION FIRST TIME - QUICK START OPERATION OPERATION - OPTIONS CALIBRATION AND PIPE OCCLUSION MEASUREMENT

More information

DIVERSE MAGMETER MF500M+ USER MANUAL. Contents INTRODUCTION FIRST TIME - QUICK START OPERATION OPERATION - OPTIONS MAGNETITE METER

DIVERSE MAGMETER MF500M+ USER MANUAL. Contents INTRODUCTION FIRST TIME - QUICK START OPERATION OPERATION - OPTIONS MAGNETITE METER Contents DIVERSE MAGMETER MF500M+ INTRODUCTION FIRST TIME - QUICK START OPERATION OPERATION - OPTIONS MAGNETITE METER CALIBRATION AND PIPE OCCLUSION MEASUREMENT TECHNIQUE SPECIFICATION USER MANUAL LIABILITY

More information

LDG FT-Meter For Yaesu FT-857 and FT-897

LDG FT-Meter For Yaesu FT-857 and FT-897 LDG FT-Meter For Yaesu FT-857 and FT-897 LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com LDG

More information

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003) (Part # S-LIB-M003) The smart sensor is designed to work with the HOBO Weather Station logger. The smart sensor has a plug-in modular connector that allows it to be added easily to a HOBO Weather Station.

More information

American Red Cross SOLARLINKFR360

American Red Cross SOLARLINKFR360 American Red Cross SOLARLINKFR360 Self-powered Digital AM/FM/NOAA Weather Radio with Flashlight, Solar Power and USB Cell Phone Charger American Red Cross Radio Line By Etón Corporation Owner s manual

More information

Using the Gill Instruments WindSonic Opt 3 Wind Speed and Direction Sensor with the HOBO RX3000 Station

Using the Gill Instruments WindSonic Opt 3 Wind Speed and Direction Sensor with the HOBO RX3000 Station Using the Gill Instruments WindSonic Opt 3 Wind Speed and Direction Sensor with the HOBO RX3000 Station This application note describes how to connect and operate the Gill WindSonic sensor (Opt 3 with

More information

HD 9408T BARO - HD 9408TR BARO HD 9908T BARO - HD 9408PS 50

HD 9408T BARO - HD 9408TR BARO HD 9908T BARO - HD 9408PS 50 HD 9408T BARO - HD 9408TR BARO HD 9908T BARO - HD 9408PS 50 BAROMETRIC PRESSURE TRANSMITTERS - STATIC PORT FOR BAROMETRIC MEASUREMENTS GENERAL DESCRIPTION HD 9408T BARO, HD 9408TR BARO and HD 9908T BARO

More information

GMR1887DAB DAB Digital and FM Radio User Guide. IMPORTANT: Please read all instructions carefully before use and keep for future reference.

GMR1887DAB DAB Digital and FM Radio User Guide. IMPORTANT: Please read all instructions carefully before use and keep for future reference. GMR1887DAB DAB Digital and FM Radio User Guide IMPORTANT: Please read all instructions carefully before use and keep for future reference. Introduction Thank you for buying the GOODMANS DAB Digital and

More information

OPERATING USER MANUAL for PRESSURE RECORDERS

OPERATING USER MANUAL for PRESSURE RECORDERS Serial No. OPERATING USER MANUAL for PRESSURE RECORDERS MNW-004 Rev. F 01/04/19 Reorder Stock No. PD1013 Palmer Wahl Instruments, Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853

More information

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 Operation and Service Manual Page 2 Manufactured by: LINCAST INTERNATIONAL PTY. LTD. 2/3 Sir Laurence Drive

More information

QUANTUM Qflash MODEL T OPERATING INSTRUCTIONS

QUANTUM Qflash MODEL T OPERATING INSTRUCTIONS QUANTUM Qflash MODEL T OPERATING INSTRUCTIONS 1.0 DESIGNATIONS 1. Removable Reflector, two positions Normal and Wide angle. 2. Flash-tube 3. Bounce Head, Rotates 180º 4. Swivel Head, Rotates ± 90º 5. Sensor

More information

PIECAL 211 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

PIECAL 211 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics Product Description Easy to use With the PIECAL 211 you can check & calibrate all your RTD instruments and measure RTD Sensors. Automatic indication of connections on the display for simple hookups. Take

More information

rino 600 series quick start manual

rino 600 series quick start manual rino 600 series quick start manual Getting Started Keys warning See the Important Safety and Product Information guide in the product box for product warnings and other important information. When using

More information

Mixer Amplifier series

Mixer Amplifier series Mixer Amplifier series with MP & FM Tuner User Manual MA MP MIXER AMPLIFIER MIC MIC AUX US B/S D/F M BASS - - + - + + - + - - + - TREBLE + - AUX MIC/LINE + + - MIXER + MA MP + - AMPLIFIER MIC MIC AUX MIC/LINE

More information

Smartzone LCD TOUCHPAD USER GUIDE.

Smartzone LCD TOUCHPAD USER GUIDE. Smartzone LCD TOUCHPAD USER GUIDE www.ias.net.au TOUCHPAD USER GUIDE Touchpad and Display Layout PAGE 2 TOUCHPAD USER GUIDE Dual Line Back lit LCD Display With scrolling zone summary Change variable values

More information

SOIL INSTRUMENTS BEAM ELECTROLEVEL, ELECTROLEVEL TILTMETER & HELM INSTALLATION MANUAL (Including Cable-Free sensor zeroing)

SOIL INSTRUMENTS BEAM ELECTROLEVEL, ELECTROLEVEL TILTMETER & HELM INSTALLATION MANUAL (Including Cable-Free sensor zeroing) SOIL INSTRUMENTS BEAM ELECTROLEVEL, ELECTROLEVEL TILTMETER & HELM INSTALLATION MANUAL (Including Cable-Free sensor zeroing) Man 173 6(A5) 04/4/2006 C. Rasmussen Phil Day Chris Rasmussen Manual No. Revision

More information

Aqua-Gen 3PV INSTRUCTIONS

Aqua-Gen 3PV INSTRUCTIONS Aqua-Gen 3PV INSTRUCTIONS INSTALLATION INSTRUCTIONS CONTROLLER: Find a suitable location to mount the control box* radio note. The controller must be installed out of direct weather and no closer than

More information

Volvo 240/260 New Face Overlay Installation Models By Dave Barton

Volvo 240/260 New Face Overlay Installation Models By Dave Barton Volvo 240/260 New Face Overlay Installation 1975-80 Models By Dave Barton These custom faces are the product of years of research and experimentation. They are printed with a special printer using waterproof

More information

1-Wire Addressable Digital Instruments. for Environmental Monitoring

1-Wire Addressable Digital Instruments. for Environmental Monitoring 1-Wire Addressable Digital Instruments for Environmental Monitoring Several 1-Wire analog-to-digital converters (ADCs) have recently been introduced that make it possible to measure a wide range of environmental

More information

English. Operating manual. Tipping bucket rain gauge HD Keep for future reference. Companies / Brands of GHM

English. Operating manual. Tipping bucket rain gauge HD Keep for future reference. Companies / Brands of GHM English Operating manual Tipping bucket rain gauge HD2015 Companies / Brands of GHM www.deltaohm.com Keep for future reference. TABLE OF CONTENTS 1 INTRODUCTION... 3 2 TECHNICAL CHARACTERISTICS... 4 3

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

wireless computer owner s manual 80mm x 110mm Black

wireless computer owner s manual 80mm x 110mm Black wireless computer owner s manual 80mm x 110mm Black Contents Package Contents... 3 Using Your Computer... 4 1.Main Unit Setup... 4 1. Initiation of Main Unit 2. Basic Display Modes 2. Overview of Button

More information

OXDALE PRODUCT LTD OPERATING AND MAINTENANCE MANUAL TM400 AND TM400 BIG BASE LOG SPLITTER KEEP FOR FUTURE USE

OXDALE PRODUCT LTD OPERATING AND MAINTENANCE MANUAL TM400 AND TM400 BIG BASE LOG SPLITTER KEEP FOR FUTURE USE OXDALE PRODUCT LTD OPERATING AND MAINTENANCE MANUAL TM400 AND TM400 BIG BASE LOG SPLITTER KEEP FOR FUTURE USE 1 CONTENTS Safety 3 Labels 5 Quick Guide 6 In Depth Instructions 8 Operating Instructions 12

More information

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics Product Description Easy to use With the PIECAL 311 you can check & calibrate all your RTD instruments and measure RTD Sensors. Automatic indication of connections on the display for simple hookups. Take

More information

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this temperature station with wireless 868MHz transmission. It not only displays the indoor temperature

More information

Always there to help you. Register your product and get support at AJB4300. Question? Contact Philips.

Always there to help you. Register your product and get support at  AJB4300. Question? Contact Philips. Always there to help you Register your product and get support at www.philips.com/support Question? Contact Philips AJB4300 User manual Contents 1 Important 2 Safety 2 2 Your FM/DAB+ clock radio 3 Introduction

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

2015 RIGOL TECHNOLOGIES, INC.

2015 RIGOL TECHNOLOGIES, INC. Service Guide DG000 Series Dual-channel Function/Arbitrary Waveform Generator Oct. 205 TECHNOLOGIES, INC. Guaranty and Declaration Copyright 203 TECHNOLOGIES, INC. All Rights Reserved. Trademark Information

More information

C84343 FAQS CONTENTS

C84343 FAQS CONTENTS C84343 FAQS We are weather enthusiasts like you and know proper running equipment is important. These FAQS provide valuable information on setup, positioning, and troubleshooting your station. We recommend

More information

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information Instruction INFOCAL 8 Energy calculator 1.0 Table of contents 1.0 Table of contents...1 2.0 Safety notes and product information...1 3.0 Installation of energy calculator...2 4.0 Installation of temperature

More information

Rain Gauge Smart Sensor (Part # S-RGA-M002, S-RGB-M002)

Rain Gauge Smart Sensor (Part # S-RGA-M002, S-RGB-M002) (Part # S-RGA-M002, S-RGB-M002) The Rain Gauge smart sensor is designed to work with HOBO Station loggers. The smart sensor has a plug-in modular connector that allows it to be added easily to a HOBO Station.

More information

Wireless Vehicle Sensor Installation Manual

Wireless Vehicle Sensor Installation Manual ACCESS CONTROLS WIRELESS ACCESS SYSTEMS Wireless Vehicle Sensor Installation Manual D A C Kit Includes: A. Transmitter Module/Cover B. Sensor/Sensor Cable C. Receiver (RB709U-NB required for some gate

More information

Instructions to Convert a 4-foot Florescent Fixture to LEDs Using 60W Power Supply Using 2 or 3 strips 30Dec15

Instructions to Convert a 4-foot Florescent Fixture to LEDs Using 60W Power Supply Using 2 or 3 strips 30Dec15 Instructions to Convert a 4-foot Florescent Fixture to LEDs Using 60W Power Supply Using 2 or 3 strips 30Dec15 Thank you for purchasing the Shoplight Solutions 4-ft conversion kit. This is a companion

More information

Sound Engineering Solutions

Sound Engineering Solutions Sound Engineering Solutions bhi NEDSP1061 Noise Reduction Module Yaesu FT-817 Version Fitting Instructions bhi 1061-104D Issue B Page 1 1. Introduction. The bhi NEDSP1061 noise reduction module is a fully

More information

Wind Transmitter First Class

Wind Transmitter First Class THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021310/07/06 Wind Transmitter First Class 4.3350.00.000 4.3350.10.000 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Yara Water Solution. Installation Guide. Product summary: - Included components - Tools for setup - Installation overview

Yara Water Solution. Installation Guide. Product summary: - Included components - Tools for setup - Installation overview Yara Water Solution Installation Guide Product summary: - Included components - Tools for setup - Installation overview Step by step installation guide: - Mounting the Base Station - Preparing the field

More information

2400AT 4 I221 I221 1A 1A T T Rev. Rev B. C

2400AT 4 I221 I221 1A 1A T T Rev. Rev B. C 4 I2211AT Rev. Rev.B I2211AT C 2400AT Contents 1. Introduction 2. Components 3. Before operation 4. Setting up your Model 2400AT 4.1 setting the year 4.2 setting date 4.3 setting time 4.4 setting day line

More information

a Loop System LA240 User manual ACCESS TO SOUND

a Loop System LA240 User manual ACCESS TO SOUND a Loop System LA240 User manual ACCESS TO SOUND The LA240 Loop System provides a practical solution for hearing aid users to listen more easily to their TV or Audio equipment via the T or Loop program

More information

For Experimenters and Educators

For Experimenters and Educators For Experimenters and Educators ARobot (pronounced "A robot") is a computer controlled mobile robot designed for Experimenters and Educators. Ages 14 and up (younger with help) can enjoy unlimited experimentation

More information

HDC Controller. Operating Manual. Rain Pro. Intelligent Irrigation Solutions. 4 or 6 Station

HDC Controller. Operating Manual. Rain Pro. Intelligent Irrigation Solutions. 4 or 6 Station Rain Pro Intelligent Irrigation Solutions HDC Controller Operating Manual 4 or 6 Station Hit Products Corporation P. O. Box 929 Lindsay, CA 93247 Phone: (559) 562-5975 Read Entire Instruction Booklet Before

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information