The all-in-one solution for wireless recording and stimulating in vivo

Size: px
Start display at page:

Download "The all-in-one solution for wireless recording and stimulating in vivo"

Transcription

1 Wireless-Systems The all-in-one solution for wireless recording and stimulating in vivo 4, 8, 16 or 32 channels Options for electrical and optical Lightweight headstages Excellent signal--noise ratio Parallel recordings possible Option access analog data

2 Energy-efficiency and flexibility Key advantage: Digital data transmission The Wireless-System converts Versatile software: Multi Channel Suite All devices of the Wireless-Systems are designed be recording continues, the headstage switches on The Wireless-System comes with the powerful and easy--use software package Multi energy-efficient. The standard battery of the headstage aumatically. Another possibility is turn off the Channel Suite. It consists of three programs and updates are available for free from converter and LED lights for video, permits continuous recording of all channels for approx. headstage completely via the data acquisition software. the MCS website. Systems is the all-in-one solution for digitized transmission, powerful receiver, 2 hours (details on back side). Recharging is then For switching on without any interference, just use the amplifying, recording, and analyzing in vivo interface board, and data acquisition Multi Channel Experimenter for data acquisition and online analysis. With an easy- realized via a USB charger. included infrared flashlight which does not disturb the data from 4, 8, 16 or 32 channels. software package. -use drag n drop interface, you simply create your virtual experiment adding e.g. For recording in animals insensitive weight, we also animal. data source, filters, spike detection, and recorder. Battery level and signal quality are The bandwidth is 1 Hz 5 khz, With its excellent signal--noise ratio, offer larger batteries, which provide longer recording Single channels can always be switched on and off for indicated here and your data is displayed in real-time. Modular setup of headstages sampled at up 40 khz per channel it is the ideal solution for recording times. Please contact Multi Channel Systems for more recording via software. This allows you adjust energy Multi Channel Analyzer for offline analysis. You just import the recorded data and The wireless headstages are built accord- simultaneously. With a resolution of 16 bit, spikes, LFP, EEG, ECG, EMG, and ECoG. information on battery options. and sampling rate whenever you like. define your in-depth analysis with additional instruments. The Multi Channel Analyzer ing your needs. The level-based con- the accuracy of your data is guaranteed. Additional inputs the interface board also supports synchronized video input for behavioral research with freely moving struction makes cusm-built headstages The systems include everything you need: allow the synchronization of your data with For power-saving, the headstage switches stand-by possible. Your headstage can consist of Small-sized headstage with integrated A/D external devices. mode as soon as the data acquisition is spped. When animals. Both, the video data and electrophysiological recordings are displayed in parallel and you can easily skip through the data from one event the next. levels for amplification and A/D conver- Multi Channel DataManager for data export for further analysis with third- sion, electrical or optical, party programs. Data files are exported in HDF5 (e.g. Matlab, Python),.nex motion sensors and many more which (Neuroexplorer) or.ced (Spike 2). Independent of the file format, the export is done are currently under development. Wireless recording system The Wireless-System from Multi Channel the recorded signals in digital data already on the headstage. Headstage A/D converter and transmitter Digital Wireless Transmission Receiver Microprocessor Interface Board Connection computer Software Data visualization and analysis Aumatically when spping data acquisition Switching via control software quickly and a data compresssion is included. This guarantees an excellent signal-noise ratio which is independent Any PC or lapp can be used from the distance between sender and receiver. Active Recording Stand-By Switched Off Low battery Marginal battery In combination with a long transmission Aumatically when starting data acquisition range, the digital data transmission permits flexible long-term experiments Switching via infrared flashlight, included in the system in large environments. and optical MCS uniquely provides headstages for optical and electrical. You do not need give up valuable recording information while stimulating; the headstages allow you Analog output any data acquistion Various possibilities for battery placement and electrode connections record and stimulate simultaneously! The headstage for optical offers an interface For maximum flexibility, we offer headstages with 2 LEDs. So in addition 4 recording channels, you connections any type of probes. Just let us know Generally, the Wireless-Systems are com- can program 2 patterns for the connected plete work stations with data acquisition LEDs. Parallel experiments The headstage for electrical has 2 dedicated The Wireless-System offers the possibility channels with current output in addition either 8 or 14 recording channels. simultaneously and software from Multi Channel Systems. However, you have the option add an analog output of all channels. as well as electrical patterns can be You can then connect your existing data designed freely via the included software Multi Channel acquisition and analyze the data in your Experimenter. software. This gives you the flexibility integrate the MCS-Wireless-System in your existing set-up and use the peripheral equipment you are familiar with - while adding valuable, undisturbed in vivo data. record from up which probe you want use and we will provide the eight one setup animals corresponding connecr. Moreover, depending on your experiment, you can also a decide where position the battery of the headstage. reduced sampling rate). Up four receivers Either fix it on the headstage itself or use a special backpack can be run in parallel in the same room, for the cable-connected battery. Independent of your with a tal number of 16 headstages. decision, be sure that the battery is small and lightweight in with (at order not influence your experiment.

3 Energy-efficiency and flexibility Key advantage: Digital data transmission The Wireless-System converts Versatile software: Multi Channel Suite All devices of the Wireless-Systems are designed be recording continues, the headstage switches on The Wireless-System comes with the powerful and easy--use software package Multi energy-efficient. The standard battery of the headstage aumatically. Another possibility is turn off the Channel Suite. It consists of three programs and updates are available for free from converter and LED lights for video, permits continuous recording of all channels for approx. headstage completely via the data acquisition software. the MCS website. Systems is the all-in-one solution for digitized transmission, powerful receiver, 2 hours (details on back side). Recharging is then For switching on without any interference, just use the amplifying, recording, and analyzing in vivo interface board, and data acquisition Multi Channel Experimenter for data acquisition and online analysis. With an easy- realized via a USB charger. included infrared flashlight which does not disturb the data from 4, 8, 16 or 32 channels. software package. -use drag n drop interface, you simply create your virtual experiment adding e.g. For recording in animals insensitive weight, we also animal. data source, filters, spike detection, and recorder. Battery level and signal quality are The bandwidth is 1 Hz 5 khz, With its excellent signal--noise ratio, offer larger batteries, which provide longer recording Single channels can always be switched on and off for indicated here and your data is displayed in real-time. Modular setup of headstages sampled at up 40 khz per channel it is the ideal solution for recording times. Please contact Multi Channel Systems for more recording via software. This allows you adjust energy Multi Channel Analyzer for offline analysis. You just import the recorded data and The wireless headstages are built accord- simultaneously. With a resolution of 16 bit, spikes, LFP, EEG, ECG, EMG, and ECoG. information on battery options. and sampling rate whenever you like. define your in-depth analysis with additional instruments. The Multi Channel Analyzer ing your needs. The level-based con- the accuracy of your data is guaranteed. Additional inputs the interface board also supports synchronized video input for behavioral research with freely moving struction makes cusm-built headstages The systems include everything you need: allow the synchronization of your data with For power-saving, the headstage switches stand-by possible. Your headstage can consist of Small-sized headstage with integrated A/D external devices. mode as soon as the data acquisition is spped. When animals. Both, the video data and electrophysiological recordings are displayed in parallel and you can easily skip through the data from one event the next. levels for amplification and A/D conver- Multi Channel DataManager for data export for further analysis with third- sion, electrical or optical, party programs. Data files are exported in HDF5 (e.g. Matlab, Python),.nex motion sensors and many more which (Neuroexplorer) or.ced (Spike 2). Independent of the file format, the export is done are currently under development. Wireless recording system The Wireless-System from Multi Channel the recorded signals in digital data already on the headstage. Headstage A/D converter and transmitter Digital Wireless Transmission Receiver Microprocessor Interface Board Connection computer Software Data visualization and analysis Aumatically when spping data acquisition Switching via control software quickly and a data compresssion is included. This guarantees an excellent signal-noise ratio which is independent Any PC or lapp can be used from the distance between sender and receiver. Active Recording Stand-By Switched Off Low battery Marginal battery In combination with a long transmission Aumatically when starting data acquisition range, the digital data transmission permits flexible long-term experiments Switching via infrared flashlight, included in the system in large environments. and optical MCS uniquely provides headstages for optical and electrical. You do not need give up valuable recording information while stimulating; the headstages allow you Analog output any data acquistion Various possibilities for battery placement and electrode connections record and stimulate simultaneously! The headstage for optical offers an interface For maximum flexibility, we offer headstages with 2 LEDs. So in addition 4 recording channels, you connections any type of probes. Just let us know Generally, the Wireless-Systems are com- can program 2 patterns for the connected plete work stations with data acquisition LEDs. Parallel experiments The headstage for electrical has 2 dedicated The Wireless-System offers the possibility channels with current output in addition either 8 or 14 recording channels. simultaneously and software from Multi Channel Systems. However, you have the option add an analog output of all channels. as well as electrical patterns can be You can then connect your existing data designed freely via the included software Multi Channel acquisition and analyze the data in your Experimenter. software. This gives you the flexibility integrate the MCS-Wireless-System in your existing set-up and use the peripheral equipment you are familiar with - while adding valuable, undisturbed in vivo data. record from up which probe you want use and we will provide the eight one setup animals corresponding connecr. Moreover, depending on your experiment, you can also a decide where position the battery of the headstage. reduced sampling rate). Up four receivers Either fix it on the headstage itself or use a special backpack can be run in parallel in the same room, for the cable-connected battery. Independent of your with a tal number of 16 headstages. decision, be sure that the battery is small and lightweight in with (at order not influence your experiment.

4 Energy-efficiency and flexibility Key advantage: Digital data transmission The Wireless-System converts Versatile software: Multi Channel Suite All devices of the Wireless-Systems are designed be recording continues, the headstage switches on The Wireless-System comes with the powerful and easy--use software package Multi energy-efficient. The standard battery of the headstage aumatically. Another possibility is turn off the Channel Suite. It consists of three programs and updates are available for free from converter and LED lights for video, permits continuous recording of all channels for approx. headstage completely via the data acquisition software. the MCS website. Systems is the all-in-one solution for digitized transmission, powerful receiver, 2 hours (details on back side). Recharging is then For switching on without any interference, just use the amplifying, recording, and analyzing in vivo interface board, and data acquisition Multi Channel Experimenter for data acquisition and online analysis. With an easy- realized via a USB charger. included infrared flashlight which does not disturb the data from 4, 8, 16 or 32 channels. software package. -use drag n drop interface, you simply create your virtual experiment adding e.g. For recording in animals insensitive weight, we also animal. data source, filters, spike detection, and recorder. Battery level and signal quality are The bandwidth is 1 Hz 5 khz, With its excellent signal--noise ratio, offer larger batteries, which provide longer recording Single channels can always be switched on and off for indicated here and your data is displayed in real-time. Modular setup of headstages sampled at up 40 khz per channel it is the ideal solution for recording times. Please contact Multi Channel Systems for more recording via software. This allows you adjust energy Multi Channel Analyzer for offline analysis. You just import the recorded data and The wireless headstages are built accord- simultaneously. With a resolution of 16 bit, spikes, LFP, EEG, ECG, EMG, and ECoG. information on battery options. and sampling rate whenever you like. define your in-depth analysis with additional instruments. The Multi Channel Analyzer ing your needs. The level-based con- the accuracy of your data is guaranteed. Additional inputs the interface board also supports synchronized video input for behavioral research with freely moving struction makes cusm-built headstages The systems include everything you need: allow the synchronization of your data with For power-saving, the headstage switches stand-by possible. Your headstage can consist of Small-sized headstage with integrated A/D external devices. mode as soon as the data acquisition is spped. When animals. Both, the video data and electrophysiological recordings are displayed in parallel and you can easily skip through the data from one event the next. levels for amplification and A/D conver- Multi Channel DataManager for data export for further analysis with third- sion, electrical or optical, party programs. Data files are exported in HDF5 (e.g. Matlab, Python),.nex motion sensors and many more which (Neuroexplorer) or.ced (Spike 2). Independent of the file format, the export is done are currently under development. Wireless recording system The Wireless-System from Multi Channel the recorded signals in digital data already on the headstage. Headstage A/D converter and transmitter Digital Wireless Transmission Receiver Microprocessor Interface Board Connection computer Software Data visualization and analysis Aumatically when spping data acquisition Switching via control software quickly and a data compresssion is included. This guarantees an excellent signal-noise ratio which is independent Any PC or lapp can be used from the distance between sender and receiver. Active Recording Stand-By Switched Off Low battery Marginal battery In combination with a long transmission Aumatically when starting data acquisition range, the digital data transmission permits flexible long-term experiments Switching via infrared flashlight, included in the system in large environments. and optical MCS uniquely provides headstages for optical and electrical. You do not need give up valuable recording information while stimulating; the headstages allow you Analog output any data acquistion Various possibilities for battery placement and electrode connections record and stimulate simultaneously! The headstage for optical offers an interface For maximum flexibility, we offer headstages with 2 LEDs. So in addition 4 recording channels, you connections any type of probes. Just let us know Generally, the Wireless-Systems are com- can program 2 patterns for the connected plete work stations with data acquisition LEDs. Parallel experiments The headstage for electrical has 2 dedicated The Wireless-System offers the possibility channels with current output in addition either 8 or 14 recording channels. simultaneously and software from Multi Channel Systems. However, you have the option add an analog output of all channels. as well as electrical patterns can be You can then connect your existing data designed freely via the included software Multi Channel acquisition and analyze the data in your Experimenter. software. This gives you the flexibility integrate the MCS-Wireless-System in your existing set-up and use the peripheral equipment you are familiar with - while adding valuable, undisturbed in vivo data. record from up which probe you want use and we will provide the eight one setup animals corresponding connecr. Moreover, depending on your experiment, you can also a decide where position the battery of the headstage. reduced sampling rate). Up four receivers Either fix it on the headstage itself or use a special backpack can be run in parallel in the same room, for the cable-connected battery. Independent of your with a tal number of 16 headstages. decision, be sure that the battery is small and lightweight in with (at order not influence your experiment.

5 Wireless-Systems: Technical specifications Number of channels 4, 8, 16 or 32 Dimensions (W x D x H) (Width w/o antennas; height w/o battery) Type of headstage W2100-HS4 W2100-HS8 W2100-HS16 W2100-HS32 W2100-HS4-op W2100-HS8-ES2 W2100-HS14-ES2 W2100-HS-EEG/EMG/Temp Dimension 13 x 13 x 5.5 mm 15.5 x 15.5 x 6.7 mm 13 x 13 x 5.5 mm Weight (Headstage without battery) Type of headstage W2100-HS4 W2100-HS8 W2100-HS16 W2100-HS32 W2100-HS4-op W2100-HS8-ES2 W2100-HS14-ES2 W2100-HS-EEG/EMG/Temp Weight of headstage 1.9 g 2.8 g (OM), 3.1 g (SR) 2.9 g 3.7 g 1.9 g 3.7 g 3.7 g 3.0 g Battery Battery types and approx. weights (Standard batteries, other capacities available on request) Battery life (until recharge) Resolution Input voltage range Sampling rate (khz per channel) Lithium-Polymer, rechargeable Capacity e.g. 32 channels with 100 mah battery: approx. 1 hour 16 bit ± 12.4 mv Sampling rate (khz/ch) Type of headstage Weight of battery (cable or battery board) 30 mah 1.5 g; 1.5 g 100 mah (standard) 3.7 g; 3.8 g 200 mah 5.1 g; 6.7 g 300 mah 8.1 g; 8.7 g Number of selected channels W2100-HS W2100-HS W2100-HS W2100-HS W2100-HS4-op Bandwidth Distance for wireless link 1 Hz 5 khz (0.1 Hz on request) 5 m guaranteed (under normal lab conditions) Control interface USB 3.0 Software: Operating system Multi Channel Suite Windows 7 or 8 (English and German versions supported) Version and higher

6 Distributed by: Multi Channel Systems MCS GmbH February 2016 Multi Channel Systems MCS GmbH Product information is subject change without notice. Products that are referred in this document may be either trademarks and/or registered trademarks of the respective owners. The publisher and the author make no claim these trademarks. Aspenhaustraße Reutlingen Germany Fon Fax

Wireless Neural Loggers

Wireless Neural Loggers Deuteron Technologies Ltd. Electronics for Neuroscience Wireless Neural Loggers On-animal neural recording Deuteron Technologies provides a family of animal-borne neural data loggers for recording 8, 16,

More information

TBSI W256 System Manual Version 1.0

TBSI W256 System Manual Version 1.0 TBSI W256 System Manual Version 1.0 Triangle BioSystems International 2224 Page Rd. Suite 108 Durham, NC 27703 Phone: (919) 361-2663 Fax: (919) 544-3061 www.trianglebiosystems.com Contents 256 CHANNEL

More information

TBSI W32 System Manual Version 3.0

TBSI W32 System Manual Version 3.0 TBSI W32 System Manual Version 3.0 Triangle BioSystems International 2224 Page Rd. Suite 108 Durham, NC 27703 Phone: (919) 361-2663 Fax: (919) 544-3061 www.trianglebiosystems.com Contents 32 CHANNEL WIRELESS

More information

from signals to sources asa-lab turnkey solution for ERP research

from signals to sources asa-lab turnkey solution for ERP research from signals to sources asa-lab turnkey solution for ERP research asa-lab : turnkey solution for ERP research Psychological research on the basis of event-related potentials is a key source of information

More information

CerePlex W. Instructions for Use. 630 Komas Drive Suite 200 Salt Lake City UT USA P F

CerePlex W. Instructions for Use. 630 Komas Drive Suite 200 Salt Lake City UT USA P F 630 Komas Drive Suite 200 Salt Lake City UT 84108 USA P +1 801.582.5533 F +1 801.582.1509 www.blackrockmicro.com CerePlex W Instructions for Use Table of Contents Table of Contents... 2 Warnings and Contraindications...

More information

An 8-Channel General-Purpose Analog Front- End for Biopotential Signal Measurement

An 8-Channel General-Purpose Analog Front- End for Biopotential Signal Measurement An 8-Channel General-Purpose Analog Front- End for Biopotential Signal Measurement Group 4: Jinming Hu, Xue Yang, Zengweijie Chen, Hang Yang (auditing) 1. System Specifications & Structure 2. Chopper Low-Noise

More information

KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com CTP8-Rotate 8 (4) channel telemetry

More information

TDT Biological Amplifier User s Guide? TDT

TDT Biological Amplifier User s Guide? TDT TDT Biological Amplifier User s Guide? 1999-2001 TDT . Table of Contents Overview...1 Connections...2 XBUS Device Caddy Installation...2 Fiber Optic Cables...2 Electrodes...2 DB4 Controller Ouput...3 HS4

More information

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits ISOBE5600 Isolated Probe Systems - ISOBE5600 Isolation system - ISOBE5600 Transient recorder Data sheet Features and Benefits ISOBE5600 Isolation system - Cost-effective - Fiber-optic isolation - Analogue-in

More information

APPENDIX E: IWX214 HARDWARE MANUAL

APPENDIX E: IWX214 HARDWARE MANUAL APPENDIX E: IWX214 HARDWARE MANUAL Overview The iworx/214 hardware in combination with LabScribe recording software provides a system that allows coordinated control of both analog inputs and outputs.

More information

1510A PRECISION SIGNAL SIMULATOR

1510A PRECISION SIGNAL SIMULATOR A worldwide leader in precision measurement solutions Portable signal source for calibrating electronic equipment and machinery monitoring systems. 1510A PRECISION SIGNAL SIMULATOR Voltage Signals Charge

More information

KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com User Manual CTP8-Rotate 8 (4)

More information

SL Handheld Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES

SL Handheld Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES FEATURES Automatic frequency and interference management Speech optimized condenser microphone capsule Clear and easy focused user interface Long operation time (up to 15 hours) Advanced power management

More information

Telemetrie-Messtechnik Schnorrenberg

Telemetrie-Messtechnik Schnorrenberg Telemetrie-Messtechnik Schnorrenberg CTP8-Rotate 8 (4) channel telemetry for rotating applications like wheels or rotors, high signal bandwidth, 16bit, software programmable Inputs for STG, TH-K, ICP or

More information

Extracellular recording with microelectrode arrays for all applications

Extracellular recording with microelectrode arrays for all applications MEA-System Extracellular recording with microelectrode arrays for all applications Well-established technology Recording from up to 256 channels Microelectrode arrays with various layouts Broad range of

More information

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE EXT-02 B EXTRACELLULAR AMPLIFIER

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE EXT-02 B EXTRACELLULAR AMPLIFIER OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE EXT-02 B EXTRACELLULAR AMPLIFIER VERSION 1.3 npi 2014 npi electronic GmbH, Bauhofring 16, D-71732 Tamm, Germany Phone +49 (0)7141-9730230; Fax: +49

More information

Your reference in Neuroscience Research. Neuroscience Suite

Your reference in Neuroscience Research. Neuroscience Suite Your reference in Neuroscience Research Neuroscience Suite Version 07/2013 Contents Alpha Omega s Neuroscience Suite Integrated workstation for recording and stimulation for both free moving and restrained

More information

SL Headmic Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES

SL Headmic Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES FEATURES Automatic frequency and interference management Excellent speech intelligibility Outstanding sound quality, omni-directional Extremely lightweight, but sturdy metal frame Sleek and unobtrusive

More information

CAEMAX D x telemetry. digital modular convenient. Modular, multi-channel telemetry system for a variety of applications. productive testing

CAEMAX D x telemetry. digital modular convenient. Modular, multi-channel telemetry system for a variety of applications. productive testing CAEMAX D x telemetry digital modular convenient Modular, multi-channel telemetry system for a variety of applications productive testing CAEMAX D x telemetry Digital, multi-channel telemetry system Advantages

More information

Weld Checkers. Resistance welding derives it s ability to form a proper weld nugget from the simple formula

Weld Checkers. Resistance welding derives it s ability to form a proper weld nugget from the simple formula Lower scrap rate Improved process control ISO 9000 data collection Decreased machine downtime Accurate machine set up Weld optimization and Design of Experiments (DoE) Welding process diagnostics Weld

More information

Bio-signal research. Julita de la Vega Arias. ACHI January 30 - February 4, Valencia, Spain

Bio-signal research. Julita de la Vega Arias. ACHI January 30 - February 4, Valencia, Spain Bio-signal research Guger Technologies OG (g.tec) Julita de la Vega Arias ACHI 2012 - January 30 - February 4, 2012 - Valencia, Spain 1. Guger Technologies OG (g.tec) Company fields bio-engineering, medical

More information

Digital Telemetry Solutions

Digital Telemetry Solutions Digital Telemetry Solutions integrated flexible reliable Wireless measurement data transmission in machinery, facilities and vehicles imc - productive testing www.imc-tm.com/telemetry Your benefits at

More information

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

C4000. inline control. Photometric Converter.  Real-time photometric converter. Factory zero for scattered light sensors C4000 Photometric Converter inline control Real-time photometric converter Factory zero for scattered light sensors Simultaneous operation of up to four inline sensors Process control functions via Remote

More information

Making Your Tour. State of the Art. TourGuide 2020-D

Making Your Tour. State of the Art. TourGuide 2020-D Making Your Tour State of the Art TourGuide 2020-D LC display shows the channel number, volume level, battery status and RF reception strength Channel selector Volume control HDE 2020-D Makes sure that

More information

Spectrum Analyzer. Spectrum Analyzer. Antenna Panel Inputs. Auxiliary Antenna Inputs. Two models available: 24 GHz and 8 GHz OSCOR

Spectrum Analyzer. Spectrum Analyzer. Antenna Panel Inputs. Auxiliary Antenna Inputs. Two models available: 24 GHz and 8 GHz OSCOR Whip antenna extension connector Auto Switching (utilizes 5 independent antennas) OSCOR ADVANTAGES FULL 24 GHz COVERAGE Headphone Jack SWEEPS FROM 10 khz TO 24 GHz AT 12.2 khz STEPS IN LESS THAN 1 SECOND

More information

SL Lavalier Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES

SL Lavalier Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES FEATURES Automatic frequency and interference management Excellent speech intelligibility Full, natural sound with low ambient noise Lockable 3.5 mm jack socket Secure 256 bit AES encryption The SL Lavalier

More information

Analog Technologies. Noise Measurement Amplifier ATNMA2 Noise Measurement Amplifier

Analog Technologies. Noise Measurement Amplifier ATNMA2 Noise Measurement Amplifier MAIN FEATURES Built-in rechargeable battery Magnifications: 300, 3,000, 30,000, 300,000, 3,000,000 Three filter bandwidths: 0.1Hz ~ 10Hz, 0.1Hz ~ 1kHz, 0.1Hz ~ 100kHz LED low battery indicator function

More information

Optimized testing of electric drives

Optimized testing of electric drives Measuring and analyzing of electrical machines testing by HBM Optimized testing of electric drives Weaknesses of the current approach Facing challenges: with the standard method? Improving the efficiency

More information

Digital Telemetry Solutions

Digital Telemetry Solutions Digital Telemetry Solutions integrated flexible reliable Wireless measurement data transmission in machinery, facilities and vehicles imc - productive testing Telemetry: the bridge to your test data Advanced

More information

HL 675 Data / Impulse Transmitter set User Manual

HL 675 Data / Impulse Transmitter set User Manual HL 675 Data / Impulse Transmitter set User Manual Version 02/2015 TAGHeuer Timin Page 1 / 8 1. Global The Set HL 675 is ideal for transferring Timing Data and Impulses. Its 500mW emitting power and its

More information

Analysis of static and time-variable magnetic fields

Analysis of static and time-variable magnetic fields Magnetometer HP-01 Analysis of static and time-variable magnetic fields Field exposure evaluation according to current standards and regulations such as Directive 2013/35/EU for workplaces Frequency-selective

More information

Green ADVANTAGES. Spectrum Analyzer Two models available: 24 GHz and 8 GHz SPECTRUM ANALYZER. Antenna Panel Inputs. Auxiliary Antenna Inputs OSCOR

Green ADVANTAGES. Spectrum Analyzer Two models available: 24 GHz and 8 GHz SPECTRUM ANALYZER. Antenna Panel Inputs. Auxiliary Antenna Inputs OSCOR Whip antenna extension connector Auto Switching (utilizes 5 independent antennas) Green ADVANTAGES OSCOR FULL 24 GHz COVERAGE Headphone Jack SWEEPS FROM 10 khz TO 24 GHz AT 12.2 khz STEPS IN LESS THAN

More information

MT32 Telemetry. KMT - Kraus Messtechnik GmbH. Multi channel telemetry system for rotating application. Powering (rotor) by battery or inductive

MT32 Telemetry. KMT - Kraus Messtechnik GmbH. Multi channel telemetry system for rotating application. Powering (rotor) by battery or inductive KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com MT32 Telemetry Multi channel telemetry

More information

Typical Doppler Signal Amplifier Application Note AN-04

Typical Doppler Signal Amplifier Application Note AN-04 Typical Doppler Signal Amplifier Application Note AN-04 RFbeam Microwave GmbH www.rfbeam.ch April 16, 2012 1/5 About This Document This application note describes a simple IF signal amplifier for Radar

More information

GV-700 VIBE PORT. Installation and. Operating Manual

GV-700 VIBE PORT. Installation and. Operating Manual GV-700 VIBE PORT Installation and Operating Manual This document may not be reproduced in any way without the prior written permission of the company. August 2016 2 GV - 700T TRANSMITTER GV - 701R RECEIVER

More information

Electroencephalograph EEG-1200J/K

Electroencephalograph EEG-1200J/K Electroencephalograph EEG-1200J/K EEG-1200 User-friendly Efficient Expandable Accurate The possibilities are endless. User-friendly Customizable new main menu You can register up to 10 examination protocol

More information

No part of this document may be reproduced or transmitted without the express written permission of Multi Channel Systems MCS GmbH.

No part of this document may be reproduced or transmitted without the express written permission of Multi Channel Systems MCS GmbH. MEA-System Manual Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted without the express written permission of Multi Channel Systems

More information

EMG Sensor Shirt. Senior Project Written Hardware Description April 28, 2015 ETEC 474. By: Dylan Kleist Joshua Goertz

EMG Sensor Shirt. Senior Project Written Hardware Description April 28, 2015 ETEC 474. By: Dylan Kleist Joshua Goertz EMG Sensor Shirt Senior Project Written Hardware Description April 28, 2015 ETEC 474 By: Dylan Kleist Joshua Goertz Table of Contents Introduction... 3 User Interface Board... 3 Bluetooth... 3 Keypad...

More information

QUICK SETUP GUIDE SECULIFE HITAM

QUICK SETUP GUIDE SECULIFE HITAM QUICK SETUP GUIDE SECULIFE HITAM The measurement and testing of measuring equipment in the field of medical technology necessitates absolute reliability and a broad range of applications. The SECULIFE

More information

TG 500 DRAHTLOSSYSTEM TG 500 PROFESSIONAL WIRELESS SYSTEM GREAT PERFORMER. CAT_TG500_17-07_EN_210x280_RZ.indd :17

TG 500 DRAHTLOSSYSTEM TG 500 PROFESSIONAL WIRELESS SYSTEM GREAT PERFORMER. CAT_TG500_17-07_EN_210x280_RZ.indd :17 TG 500 DRAHTLOSSYSTEM TG 500 PROFESSIONAL WIRELESS SYSTEM GREAT PERFORMER CAT_TG500_17-07_EN_210x280_RZ.indd 1 1 04.08.17 11:17 TG 500 WIRELESS SYSTEM TG 500 WIRELESS SYSTEM GREAT PERFORMER 2 CAT_TG500_17-07_EN_210x280_RZ.indd

More information

potentiostat/galvanostat/impedance analyser

potentiostat/galvanostat/impedance analyser potentiostat/galvanostat/impedance analyser Rev. 5-2015 Contents Contents PalmSens3: potentiostat/galvanostat/impedance anayser...2 Supported techniques...3 Specifications of general parameters...4 System

More information

WMS 450 Wireless Microphone System

WMS 450 Wireless Microphone System Half 19 all metal case diversity receiver Automatic frequency setup function for quick and easy operation 12 pre-programmed frequencies per group Infrared link of all frequency and setup data to the transmitter

More information

PDL 650. Acoustic PD Fault Localization in High-Voltage Equipment

PDL 650. Acoustic PD Fault Localization in High-Voltage Equipment PDL 650 Acoustic PD Fault Localization in High-Voltage Equipment Identifying Problems within Steel Walls As a result of increased demand for power, high voltage equipment is being subjected to ever greater

More information

SpeechLine Digital Wireless SL Headmic Set

SpeechLine Digital Wireless SL Headmic Set 1/6 FEATURES Automatic frequency and interference management Excellent speech intelligibility Outstanding sound quality, omni-directional Extremely lightweight, but sturdy metal frame Sleek and unobtrusive

More information

Digital 6000 SK 6000 Bodypack transmitter

Digital 6000 SK 6000 Bodypack transmitter 1/5 FEATURES Digital, lightweight and rugged high performance body pack with a wide selection of microphones or as an instrument transmitter Intermodulation-free even at close proximity to multiple transmitters

More information

Neurophysiology Research

Neurophysiology Research Neurophysiology Research ADINSTRUMENTS making science easier PowerLab Systems for Neurophysiology and Electrophysiology ADInstruments offers a variety of solutions for neuroscientists and electrophysiologists

More information

ni.com Sensor Measurement Fundamentals Series

ni.com Sensor Measurement Fundamentals Series Sensor Measurement Fundamentals Series Introduction to Data Acquisition Basics and Terminology Litkei Márton District Sales Manager National Instruments What Is Data Acquisition (DAQ)? 3 Why Measure? Engineers

More information

Biomedical Sensor Systems Laboratory. Institute for Neural Engineering Graz University of Technology

Biomedical Sensor Systems Laboratory. Institute for Neural Engineering Graz University of Technology Biomedical Sensor Systems Laboratory Institute for Neural Engineering Graz University of Technology 2017 Bioinstrumentation Measurement of physiological variables Invasive or non-invasive Minimize disturbance

More information

SpeechLine Digital Wireless SL Lavalier Set

SpeechLine Digital Wireless SL Lavalier Set 1/5 FEATURES Automatic frequency and interference management Excellent speech intelligibility Full, natural sound with low ambient noise Lockable 3.5 mm jack socket Secure 256 bit AES encryption The includes

More information

HL 670 Data / Impulse Transmitter set User Manual. Version 07/2010

HL 670 Data / Impulse Transmitter set User Manual. Version 07/2010 HL 670 Data / Impulse Transmitter set User Manual Version 07/2010 1. Global The Set HL670 is ideal for transferring Timing Data and Impulses. Its 500mW emitting power and its licence free frequency range

More information

Chapter 4 4. Optoelectronic Acquisition System Design

Chapter 4 4. Optoelectronic Acquisition System Design 4. Optoelectronic Acquisition System Design The present chapter deals with the design of the optoelectronic (OE) system required to translate the obtained optical modulated signal with the photonic acquisition

More information

NEWS RELEASE IMEC REPORTS TWO WIRELESS PLATFORMS FOR BIOMEDICAL MONITORING

NEWS RELEASE IMEC REPORTS TWO WIRELESS PLATFORMS FOR BIOMEDICAL MONITORING NEWS RELEASE IMEC REPORTS TWO WIRELESS PLATFORMS FOR BIOMEDICAL MONITORING EMBEDDED SYSTEMS SILICON VALLEY IMEC WIRELESS SENSOR NODE CONFERENCE TRACK APRIL 4, 2007, 2:00PM - 3:30PM HILTON, ALMADEN ROOM

More information

PSM1000. In-Ear Personal Monitoring Systems. PSM1000 In-Ear Personal Systems THE SOUND OF CONFIDENCE.

PSM1000. In-Ear Personal Monitoring Systems. PSM1000 In-Ear Personal Systems THE SOUND OF CONFIDENCE. PSM1000 In-Ear Personal Monitoring Systems PSM1000 In-Ear Personal Systems THE SOUND OF CONFIDENCE. PSM 900 In-Ear Personal Monitoring System P9RA Wireless Bodypack Receiver PSM 900 and PSM 1000 In-Ear

More information

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011 EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011 All-in-one Digital EMI Analyzer 10 Hz - 3 GHz PMM 9010/30P EMI Analyzer 10 Hz - 3 GHz Our trek started in a small laboratory over 25

More information

ISO-80. Isolated Differential Amplifier. INSTRUCTION MANUAL. Serial No. World Precision Instruments

ISO-80. Isolated Differential Amplifier.  INSTRUCTION MANUAL. Serial No. World Precision Instruments Isolated Differential Amplifier www.wpiinc.com INSTRUCTION MANUAL Serial No. 102810 World Precision Instruments CONTENTS ABOUT THIS MANUAL... 1 INTRODUCTION... 2 INSTRUMENT DESCRIPTION... 3 Parts List...

More information

Narda EMF drive test solution

Narda EMF drive test solution Area Monitor System AMB-8059 Car Mounting Kit option Narda EMF drive test solution ITU-T K.113 Compliant Automated EMF drive test solution covered by isotropic antennas Interchangeable probes from 10 Hz

More information

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

CTP16-Rotate. KMT - Kraus Messtechnik GmbH KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com CTP16-Rotate 16 channel telemetry

More information

TS-900/800 SERIES INFRARED WIRELESS CONFERENCE SYSTEM

TS-900/800 SERIES INFRARED WIRELESS CONFERENCE SYSTEM TS-900/800 SERIES INFRARED WIRELESS CONFERENCE SYSTEM Installation made easier than ever thanks to infrared system coupled with clear sound amplification. Wireless conference system provides flexible adaptation

More information

NHT 3DL. The new landmark meter for electromagnetic safety. Percipere Aestimare et Inquirere

NHT 3DL. The new landmark meter for electromagnetic safety. Percipere Aestimare et Inquirere NHT 3DL The new landmark meter for electromagnetic safety Percipere Aestimare et Inquirere NHT 3DL The new reference meter for the European directive 2013/35/EU NHT 3DL is a brand-new electromagnetic field

More information

Your partner for reliable detection technology

Your partner for reliable detection technology E N V I R O N M E N T A L C L E A N U P A N D G E O M A G N E T I C S U R V E Y Your partner for reliable detection technology D I V I S I O N S... a division of the FOERSTER Group Competence through innovation

More information

MPD 600. High-End Measurement and Analysis System for Partial Discharges (PD)

MPD 600. High-End Measurement and Analysis System for Partial Discharges (PD) MPD 600 High-End Measurement and Analysis System for Partial Discharges (PD) Partial Discharge Analysis The MPD 600 partial discharge analysis system is a precise and modular high-end toolbox for detecting,

More information

Stimulus Generator Manual STG 4004 and STG 4008

Stimulus Generator Manual STG 4004 and STG 4008 Stimulus Generator Manual STG 4004 and STG 4008 Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted without the express written permission

More information

AVL X-ion. Adapts. Acquires. Inspires.

AVL X-ion. Adapts. Acquires. Inspires. AVL X-ion Adapts. Acquires. Inspires. THE CHALLENGE Facing ever more stringent emissions targets, the quest for an efficient and affordable powertrain leads invariably through complexity. On the one hand,

More information

VLR-502 Wireless System. Owner s Guide

VLR-502 Wireless System. Owner s Guide VLR-502 Wireless System Owner s Guide Introduction Thanks for purchasing a Vokal wireless microphone. Please read this manual carefully before connecting the product and turning it on, in order to understand

More information

ELECTRONIC DESIGN & ENGINEERING. ICP_FM3 Versatile DC AC IEPE Signal Conditioning. 1 ICP_FM3 Introduction

ELECTRONIC DESIGN & ENGINEERING. ICP_FM3 Versatile DC AC IEPE Signal Conditioning. 1 ICP_FM3 Introduction 1 ICP_FM3 Introduction ICP_FM3 is a versatile signal conditioning module for DC / AC or IEPE (ICP TM ) applications. The amplifying circuit is additionally equipped with a switchable constant current source,

More information

Portable Wideband Jamming System - PWJ1 Developed and manufactured in Germany

Portable Wideband Jamming System - PWJ1 Developed and manufactured in Germany PWJ1 Developed and manufactured in Germany PWJ1 4Band & 6Band 100% Made in Germany - all main components and system parts are made in Germany, System can be exported with export license from German BAFA.

More information

Exposure Level Tester ELT-400

Exposure Level Tester ELT-400 Safety Evaluation within a Magnetic Field Environment Exposure Level Tester ELT-400 Direct Evaluation of Field Exposure Compared to Major Standards (IEEE C95.6) Automatic Exposure Evaluation for Various

More information

Bechrasoft Srl. Price List. Model Description Internal Price. Vehicle 4G GPS WIFI Cell Phone Jammer TG-101A 6 405,00

Bechrasoft Srl. Price List. Model Description Internal Price. Vehicle 4G GPS WIFI Cell Phone Jammer TG-101A 6 405,00 Bechrasoft Srl Price List Model Description Internal Price TG- 101A6 Vehicle 4G GPS WIFI Cell Phone Jammer TG-101A 6 405,00 1. can be used in the car directly, car adaptor available 2.with Fans and heat

More information

SL TS 133 GN Set DW FEATURES

SL TS 133 GN Set DW FEATURES FEATURES Qi Charging - most common wireless Charging standard Clear battery life indication via dedicated battery status LEDs Includes everything needed to install and use the wireless SL Tablestand 133-S

More information

Why partial discharge testing makes good sense

Why partial discharge testing makes good sense Why partial discharge testing makes good sense PD measurement and analysis have proven to be reliable for detecting defects in the insulation system of electrical assets before major damage or a breakdown

More information

FAG Detector II the mobile among data collectors. Technical Product Information

FAG Detector II the mobile among data collectors. Technical Product Information FAG II the mobile among data collectors Technical Product Information Application Condition-based maintenance Principle Application The FAG II is a vibration measuring device and data collector rolled

More information

Weld Checkers RESISTANCE WELDING

Weld Checkers RESISTANCE WELDING KEY FEATURES Lower scrap rate Improved process control ISO 9000 data collection Decreased machine downtime Accurate machine set up Weld optimization and Design of Experiments (DoE) Welding process diagnostics

More information

Ground vibration testing: Applying structural analysis with imc products and solutions

Ground vibration testing: Applying structural analysis with imc products and solutions Ground vibration testing: Applying structural analysis with imc products and solutions Just as almost any mechanical structure, aircraft body parts or complete aircrafts can be modelled precisely and realistically

More information

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN Description The setup of a radiated immunity test system can be done in the conventional way with many separate instruments or in a more comfortable and less risky way with our new EMC control unit, type

More information

DEDICATED TO SPEECH. Experience Simplicity with SpeechLine Digital Wireless

DEDICATED TO SPEECH. Experience Simplicity with SpeechLine Digital Wireless DEDICATED TO SPEECH Experience Simplicity with SpeechLine Digital Wireless EASY RELIABLE FUTURE-PROOF SPEECHLINE DIGITAL WIRELESS The world s first digital wireless microphone exclusively for speech. No

More information

MEA Amplifier for Inverse Microscopes Manual

MEA Amplifier for Inverse Microscopes Manual MEA Amplifier for Inverse Microscopes Manual Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted without the express written permission

More information

SL TS 153 GN-L Set DW

SL TS 153 GN-L Set DW FEATURES Easy wireless charging Clear battery life indication via dedicated battery status LEDs Includes everything needed to install and use the wireless SL Tablestand 153-S DW Can be remote controlled

More information

Series GLET Accessory for dataloggers series GL in modular enclosure

Series GLET Accessory for dataloggers series GL in modular enclosure PRESSURE LOAD TORQUE POSITION ROTARY ANGLE TILT ACCELERATION VIBRATION RATE SIGNAL CONDITIONER DATALOGGER Series GLET Accessory for dataloggers series GL in modular enclosure Models: GLET-IU-BNC-BA4 passive,

More information

Brain Computer Interface Control of a Virtual Robotic System based on SSVEP and EEG Signal

Brain Computer Interface Control of a Virtual Robotic System based on SSVEP and EEG Signal Brain Computer Interface Control of a Virtual Robotic based on SSVEP and EEG Signal By: Fatemeh Akrami Supervisor: Dr. Hamid D. Taghirad October 2017 Contents 1/20 Brain Computer Interface (BCI) A direct

More information

evolution wireless G4 ew 100 G4-835-S ew 100 G4-845-S ew 100 G4-865-S Vocal Set

evolution wireless G4 ew 100 G4-835-S ew 100 G4-845-S ew 100 G4-865-S Vocal Set 1/7 Versatile wireless systems for those who sing, speak or play instruments with up to 42 MHz tuning bandwidth in a stable UHF range and fast, simultaneous setup of up to 12 linked systems. State-of-the-art

More information

potentiostat/galvanostat/impedance analyser

potentiostat/galvanostat/impedance analyser potentiostat/galvanostat/impedance analyser Rev. 9-2014 potentiostat/galvanostat/impedance PalmSens3 is a battery-powered, handheld instrument which allows the application of most of the relevant voltammetric,

More information

MAGNETIC FIELD METER Operator s Manual

MAGNETIC FIELD METER Operator s Manual Edition 4.4 September 2011 MAGNETIC FIELD METER 3000 Operator s Manual The MFM 3000 is a professional magnetic field instrument To make the best use of the instrument we recommend that you read this manual

More information

UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences

UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences EECS 145L: Electronic Transducer Laboratory FINAL EXAMINATION Fall 2013 You have three hours to

More information

TA-80. Digital Plug-on Transmitter

TA-80. Digital Plug-on Transmitter Digital Plug-on Transmitter MIPRO Digital Plug-on Transmitter The ways how microphone output connects to sound system The microphone output connects to sound system with a microphone cable is the easiest

More information

Potentiostat/Galvanostat/Zero Resistance Ammeter

Potentiostat/Galvanostat/Zero Resistance Ammeter Potentiostat/Galvanostat/Zero Resistance Ammeter HIGHLIGHTS The Interface 1000 is a research grade Potentiostat/Galvanostat/ZRA for use in general electrochemistry applications. It is ideal for corrosion

More information

MAGNETIC FIELD METER Operator s Manual

MAGNETIC FIELD METER Operator s Manual Edition 3.1 2009-09-03 MAGNETIC FIELD METER 2000 Operator s Manual The MFM 2000 is a professional magnetic field instrument To make the best use of the instrument we recommend that you read this manual

More information

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter 1 BTS256-E Preliminary Datasheet Technological Advances in General Lighting The latest trends in general lighting involve replacing traditional light sources with SSL Solid State Lighting for energy savings,

More information

Test Plan for Hearing Aid Compatibility

Test Plan for Hearing Aid Compatibility Test Plan for Hearing Aid Compatibility Version Number 3.1 February 2017 2017 CTIA - The Wireless Association. All rights reserved. CTIA hereby grants to CTIA Authorized Testing Laboratories (CATLs), and

More information

SpeechLine Digital Wireless SL Boundary Set DW

SpeechLine Digital Wireless SL Boundary Set DW 1/6 FEATURES Wireless inductive charging Clear battery life indication via dedicated battery status LEDs Remote monitoring and control with the Sennheiser Control Cockpit The includes the wireless boundary

More information

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TEC-B-01M VOLTAGE CLAMP MODULE FOR EPMS SYSTEMS. VERSION 1.2 npi 2014

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TEC-B-01M VOLTAGE CLAMP MODULE FOR EPMS SYSTEMS. VERSION 1.2 npi 2014 OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TEC-B-01M VOLTAGE CLAMP MODULE FOR EPMS SYSTEMS VERSION 1.2 npi 2014 npi electronic GmbH, Bauhofring 16, D-71732 Tamm, Germany Phone +49 (0)7141-9730230;

More information

GENERAL OPERATING INFORMATION

GENERAL OPERATING INFORMATION Fife Corporation P.O. Box 26508, Oklahoma City, OK 73126, USA Phone: 405.755.1600 / Fax: 405.755.8425 www.fife.com / E-mail: fife@fife.com OPERATING MANUAL GENERAL OPERATING INFORMATION General The SDE-30

More information

AD8232 EVALUATION BOARD DOCUMENTATION

AD8232 EVALUATION BOARD DOCUMENTATION One Technology Way P.O. Box 9106 Norwood, MA 02062-9106 Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com AD8232 EVALUATION BOARD DOCUMENTATION FEATURES Ready to use Heart Rate Monitor (HRM) Front end

More information

CSM High-Voltage Measurement Systems

CSM High-Voltage Measurement Systems CSM High-Voltage Measurement Systems Safe Measurement on High-Voltage Components CSM HV Modules // High-Voltage Safe Measurement Systems Safe Measurement on High-Voltage Components E-mobility: enhancing

More information

Analog Circuits and Systems

Analog Circuits and Systems Analog Circuits and Systems Prof. K Radhakrishna Rao Lecture 21: Filters 1 Review Integrators as building blocks of filters Frequency compensation in negative feedback systems Opamp and LDO frequency compensation

More information

D10 Demonstration Board

D10 Demonstration Board D10 Demonstration Board D10 demonstration board side 1 Contents Demonstration board description 3 Measurement technology - Disturbance immunity 4 E1 disturbance immunity development system 4 P1 mini burst

More information

Cable Identifier Reliable cable selection for energised and de-energised cables

Cable Identifier Reliable cable selection for energised and de-energised cables Reliable cable selection for energised and de-energised cables Inexpensive cable selection system Easy to operate Safe to handle Very small DESCRIPTION Clear identification of a cable before it is cut

More information

*Most details of this presentation obtain from Behrouz A. Forouzan. Data Communications and Networking, 5 th edition textbook

*Most details of this presentation obtain from Behrouz A. Forouzan. Data Communications and Networking, 5 th edition textbook *Most details of this presentation obtain from Behrouz A. Forouzan. Data Communications and Networking, 5 th edition textbook 1 Multiplexing Frequency-Division Multiplexing Time-Division Multiplexing Wavelength-Division

More information

MEA Amplifier for Upright Microscopes Manual

MEA Amplifier for Upright Microscopes Manual MEA Amplifier for Upright Microscopes Manual Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted without the express written permission

More information

Selective and broadband high frequency field analysis

Selective and broadband high frequency field analysis ELECTRIC AND MAGNETIC FIELD ANALYZER EHP-200A Selective and broadband high frequency field analysis New solution for isotropic measurements in the 9 khz 30 MHz range Electric Fields from 0.02 to 1000 V/m

More information

Wireless Animal Monitoring

Wireless Animal Monitoring Wireless Animal Monitoring Telemetric Acquisition of Pressure, Biopotentials, SNA and Temperature World-Class Systems Complete Solutions The latest telemetry technologies and data acquisition systems have

More information