Kyowa Measuring Instruments Digest Edition 2017 to 2018

Size: px
Start display at page:

Download "Kyowa Measuring Instruments Digest Edition 2017 to 2018"

Transcription

1 Kyowa Measuring Instruments Digest Edition 2017 to 2018 Strain Gages Load Cells Pressure Transducers Acceleration Transducers Torque Transducers Displacement Transducers Dynamic Strain Amplifiers Data Loggers Data Recorders/Data Analyzers Instrumentation Amplifiers Software Automotive Test Equipment Traffic System Civil Engineering/Construction Instruments

2 Strain Gages Applications Wire Strain Gages KC Foil Strain Gage for Printed Boards KFRS Universal Recorder EDX-100A Stress measurement of precast concrete Sensor Interface PCD-400A Stress measurement when a PCB is mounted General-purpose Foil Strain Gages KFGS General-purpose Foil Strain Gages KFGS Sensor Interface PCD-400A Stress measurement of plastic parts Universal Recorder EDX-200A Stress measurement during strength testing of a shutter General-purpose Foil Strain Gages KFGS series / KFG series They use polyimide resin for the base part that is approx. 13µm thick. It ensures excellent flexibility. The outstanding moisture proof enables them to operate in outdoor measurement effectively. Unless directly exposed to water drop, no coating treatment is required. Applications are for general purposes, stress analysis, torque measurements, narrow lines, shearing stresses, stress concentraions (uniaxial 5-element, biaxial 5-element). Applicable adhesive and operating temperature range after curing CC-33A : 196 to 120ºC (For vinyl-coated cables: -10 to 80ºC.) CC-35 : 30 to 120ºC (For vinyl-coated cables: -10 to 80ºC.) CC-36 : 30 to 100ºC (For vinyl-coated cables: -10 to 80ºC.) EP-340 : 55 to 150ºC (For vinyl-coated cables: -10 to 80ºC.) PC-600 : 196 to 150ºC (For vinyl-coated cables: -10 to 80ºC.) Gage Length 0.2, 0.3, 1, 2, 3, 4, 5, 6, 10, 20, 30 mm Uniaxial, biaxial, triaxial, quadraxial, uniaxial 5-element, and biaxial 5-element Expansion Coefficient 5, 11, 16, 23, 27x10-6 / C 60, 120, 350, 500, and 1000 Ω *Lead-wire: Polyester-coated copper wire (2 to 100 cm), vinyl-coated cable (15 cm to 30 m), and middle temperature cable (15 cm to 30 m) Uniaxial Biaxial 0 /90 Stacked arrange Uniaxial 5-element Uniaxial with 2-wire cable Triaxial 0 /120 /240 Plane arrangement Uniaxial with 3-wire cable Triaxial 0 /90 /45 Stacked arrangement Biaxial 5-element Uniaxial for shearing stress Quadraxial 0 /30 /90 /150 Plane arrangement 01 Triaxial 0 /90 /45 Stacked arrangement with 3-lead-wire cables Biaxial, 0 /90 for torque measurement

3 Foil Strain Gages with Gage Terminal KFG Gage with terminals for easy connection/disconnection lead wires Operating temperature: -196 to120 C (CC-33A) Waterproof Foil Strain Gages KFWB /KFWS Usable either outdoor or underwater (100 h or more under water of 10 MPa) Operating temperature: -10 to 80 C (CC-33A) Gage Length Expansion Coefficient 1, 2 mm Uniaxial, biaxial, triaxial 11, 16, / C 120 Ω Gage Length Expansion Coefficient 2, 5 mm Uniaxial, biaxial 0 /90 stacked rosette, triaxial 0 /90 /45 stacked rosette (Triaxial is available only for KFWB) 11, 16, and / C 120, 350 Ω (KFWS: 120 Ω only) Foil Strain Gages for Measuring Axial Tension of Bolts KFG-C20 When it is difficult to bond a gage to the surface of a bolt for tightening stress measurement, etc., these KFG gages are embedded into the hole bored from the top head of the bolt. Gage Length Expansion Coefficient *Boring diameter: 2 mm 1.5, 3 mm Uniaxial / C 120 Ω Weldable Waterproof Foil Strain Gages KCW Welding type requires no coating treatment. Operating temperature: -20 to 100 C Gage Length Expansion Coefficient 5 mm Uniaxial 1-element / C 120 Ω Strain Gages for Concrete KFG/KC/KM/KMC For strain measurement of concrete. Foil Strain Gages with a Temperature Sensor KFGT Foil strain gage incorporating a T-type thermocouple. Highly precisely compensates the thermally-induced apparent strain. Operating temperature: -10 to 120 C (CC-33A) Foil Gages (KFG) Operating temperature: -10 to 80 C (CC-35) (parallel vinyl wire) Gage Length Expansion Coefficient 10, 20, 30 mm Uniaxial, biaxial 0 /90 stacked rosette, and triaxial 0 /90 /45 stacked rosette (Biaxial and triaxial are available only for a gage length of 10 mm.) / C 120 Ω Gage Length Expansion Coefficient 2, 5 mm Uniaxial 11, 16, 23, / C 120 Ω *With polyester-coated copper wire 1 m Wire Strain Gages (KC) Operating temperature: -30 to 120 C (CC-35) Gage Length Expansion Coefficient 60, 70, 80, 120 mm Uniaxial / C 120 Ω Embedded Strain Gages (KM) Operating temperature: -10 to 70 C Foil Strain Gages KFR Gage Length Expansion Coefficient 30, 120 mm Uniaxial / C 120 Ω Excellent temperature characteristics in a wide temperature range Operating temperature: -196 to 150 C (PC-600) Concrete-embedded Strain Gages (KMC) Operating temperature: Normal temperature to 70 C Gage Length Expansion Coefficient 0.15, 0.2, 0.5, 1, 2, and 5 mm Uniaxial, triaxial 0 /90 /45 plane arrangement, and uniaxial 5-element 11, 16, / C 120, 350 Ω Gage Length Expansion Coefficient 80 mm Uniaxial 120 Ω 02

4 Foil Strain Gages for Composite Materials KFRP Suitable for strain measurement of composite materials such as CFRP and GFRP Operating temperature: -55 to 200 C (EP-34B) Gage Length Expansion Coefficient 2, 5 mm Uniaxial, triaxial 0 /90 /45 plane arrangement 1, 3, 6, / C 120, 350 Ω Foil Strain Gages for Printed Boards KFRS Uniaxial: mm, biaxial and triaxial: mm Operating temperature: -10 to 80 C (CC-33A) Gage Length Expansion Coefficient 0.2, 1 mm Uniaxial, biaxial 0 /90 plane arrangement, and triaxial 0 /90 /45 plane arrangement / C 120 Ω *Self-temperature-compensation range: -30 to120 C, suitable for temperature cycle tests Foil Strain Gages for Plastics KFP Suitable for strain measurement of plastics such as acrylic resin. Operating temperature: -20 to 80 C (CC-33A) Gage Length 2, 5 mm Expansion Coefficient Uniaxial / C 120, 350 Ω Semiconductor Strain Gages 8-times enlarged view KSPB /KSN/KSPH/KSPL Semiconductor used for the resistive element ensures several 10 times higher sensitivity than foil strain gages. Operating temperature: -50 to 120 C (CC-33A) Encapsulated Strain Gages KHCX/KHCV/KHCR/KHCS/KHCM/KHC Hermetically sealed weldable strain gages. Max. operating temperature KHCX 950 C KHCV 800 C (dynamic) KHCS KHCR 750 C KHCM 650 C KHC 550 C (dynamic), 500 C (static) Gage Length Expansion Coefficient 120 Ω *Material: Inconel 600 except for KHC-G9 made of SUS 321 *The specifications are for reference purpose only. Actual values may vary depending on operating conditions including temperatures. High-temperature Foil Strain Gages KFU Superior characteristics over a wide temperature range. Operating temperature: -196 to 350 C (PI-32) Gage Length Expansion Coefficient 2, 5 mm Uniaxial, biaxial 0 /90 stacked rosette, and triaxial 0 /90 /45 stacked rosette 11, 16, / C 120, 350 Ω [Approx. operating time] *72 h or less at 350 C, 360 h or less at 300 C Adhesives: PI-32 (Actual values may vary depending on operating conditions.) High-temperature Foil Strain Gages KH Metal base enables easy bonding of the 350 Ω KH gage with a small-sized spot welder. Operating temperature: -50 to 350 C Gage Length 5 mm Expansion Coefficient 5 mm (KHCR, KHCM, and KHCV) 10 mm (KHCX, KHCS, KHCM, and KHC) 20 mm (KHC) Uniaxial 2-element temperature-compensation type (KHCV: Uniaxial 1-element) / C (KHCX, KHCR, KHCS, KHCM, and KHC) / C (KHCX, KHCR, KHCS, KHCM, and KHC) / C (KHCS, KHCR, KHCM, and KHC) Uniaxial 11, / C 350 Ω [Approx. operating time] *24 h or less at 350 C, 72 h or less at 300 C (Actual values may vary depending on operating conditions.) Gage Length 1, 2, 3, 4, 6, 7, 9 mm Uniaxial, biaxial 0 /90 plane arrangement, and uniaxial 2-element 11, / C Expansion Coefficient (Self-temperature-compensation type: KSN and KSPB-F2 only) 60, 120, 350, 1000, 2000, Ω *Semiconductor gages with no gage base are also available. High-temperature Foil Strain Gages KFH Less thermal output and excellent temperature characteristics Operating temperature: -196 to 250 C Gage Length 0.2, 0.5, 1, 2, 5 mm Expansion Coefficient Uniaxial, triaxial 0 /90 /45 plane arrangement 11, 16, / C 120, 350 Ω [Approx. operating time] *24 h or less at 250 C, (PI-32, PC-600), 120 h or less at 200 C (EP-34B) (Actual values may vary depending on operating conditions.) 03

5 Low-temperature Foil Strain Gages KFL Suitable for strain measurement of tanks and vessels containing lowtemperature liquid such as LNG and LPG. Applicable adhesive and operating temperature range after curing EP-270: 269 to 30 C PC-600: 269 to 150 C CC-33A: 196 to 120 C Shielded Foil Strain Gages KFS Shielded by the copper foil covering the whole body. Thus, if a large current flows to or around the gage bonding site, noise is prevented from entering the measuring circuit. Operating temperature: -196 to 120 C (CC-33A) Gage Length Expansion Coefficient 0.2, 0.5, 1, 2, 5, 30 mm Uniaxial, triaxial 0 /90 /45 plane arrangement 5, 11, 16, / C (5 is available only for a gage length of 30 mm) Gage Length Expansion Coefficient 5 mm Uniaxial 11, 16, / C 120, 350 Ω 120, 350 Ω High-elongation Foil Strain Gages KFEM Enables strain measurement for maximum elongation of 20% to 30% (At room temperature). Suitable for tensile tests of material. Operating temperature: -20 to 80 C (CC-36) Foil Strain Gage for Hydrogen Gas Environment KFV Enables stable strain measurement under highpressure in hydrogen gas with least hydrogen effects on the gage resistance. Operating temperature: -30 to 80 C (PC-600) Gage Length 1, 2, 5, 10 mm Gage Length 2 mm Expansion Coefficient Uniaxial Expansion Coefficient Uniaxial 120 Ω 350 Ω High-elongation Foil Strain Gages KFEL Enables strain measurement for maximum elongation of approx. 10% to 15%. Suitable for tensile tests of materials. Operating temperature: -10 to 80 C (CC-36) Foil Strain Gages for Bending Strain Measurement KFF Have one each sensing element on both the upper and lower sides of the thick plastic base. Thus, if allowing no gage to be bonded directly to the inside of the measuring object as in the case of measuring stress due to internal pressure in high-pressure vessels or stress measurement in box structures such as bridge girders, the KFF series gages will be bonded to the surface to obtain strain at the rear. Operating temperature: -50 to 80 C (CC-33A) Gage Length Expansion Coefficient Non-inductive Foil Strain Gages KFN The gage element is made of a special alloy which provides less magnetoresistant effect and the shape is designed to eliminate induction. Thus, the KFN series foil strain gages measures strain accurately under AC magnetic environments. Operating temperature: -196 to 120 C (CC-33A) Gage Length Expansion Coefficient 2, 5 mm Uniaxial, biaxial 0 /90 plane arrangement, and triaxial 0 /90 /45 plane arrangement 120 Ω 2, 5 mm Uniaxial, biaxial 0 /90 plane arrangement 11, 16, and / C 350 Ω Gage Length Expansion Coefficient 30 mm Uniaxial 11, 16, and / C 350 Ω Foil Strain Gages with a Protector KCH Suitable for weighing tanks and hoppers and for measuring tare weight of tracks. Moisture and waterproofed Operating temperature: -40 to 100 C (CC-33A) Gage Length Expansion Coefficient 2, 5 mm Uniaxial, biaxial 0 /90 stacked rosette, and triaxial 0 /90 /45 stacked rosette Bridge for bending or shearing stress measurement / C 350 Ω *With vinyl-coated shield cable KCH-5A-1 04

6 Embedded Gages KMP Embedded in resin, the KMP gage measures cure-shrinkage and internal strain. Compensated temperature: 20 to 120 C Gage Length Expansion Coefficient Crack Gages KV Measures the development length and velocity of cracks. High response speed Applicable to both flat and curved surfaces. Detect Length Expansion Coefficient Adhesives 1 mm Uniaxial 120 Ω 4.6, 25.2 mm 1 Ω To obtain good measurement results, we offer suitable adhesive for materials of measuring objects, gage bases, and measuring requirements. Gage Bonding Tool Kit GTK-77 Tool Kit Includes almost all tools, gage terminals, solder and other expendables required for gage bonding work. Gage Bonding Tool Kit GTK-55K Tool Kit Includes almost all tools required for gage bonding work. Compact Spot Welder GW-3C Developed to install encapsulated strain gages and to fix high-temperature lead wires. The GW-3C is an easy-to-use welder providing an increased welding capability and allowing continuously variable setting of welding energy. Gage Terminals CC-33A PC-600 Gage terminals are applied to the connection between strain gages and lead wires to protect gage leads. They are available in various materials and shapes. Model CC-33A CC-35 Types Instantaneous adhesive cured at normal temperature Instantaneous adhesive cured at normal temperature Operating Major Applicable Materials Temperature ( C) Metals (Steel, stainless steel, copper, aluminum alloys, etc.) -196 to 120 Plastics Composite materials Rubber -30 to 120 Concrete Mortar Wood Coating Agents Coating agents are applied to strain gages and gage terminals to prevent them from adsorbing moisture. These agents are available in a variety of types including wax, rubber and putty. CC-36 Instantaneous adhesive cured at normal temperature -30 to 100 Metals (Steel, stainless steel, copper, aluminum alloys, magnesium alloy, etc.) Plastics Composite materials Print PCB Concrete Mortar Wood Rubber EP-270 Cured at normal temperature -269 to 30 Metals (Steel, stainless steel, aluminum alloy, etc.) EP-340 Cured at normal temperature or by heating -55 to 150 Metals (Steel, stainless steel, aluminum alloy, etc.) C-5 VMTAPE KE-4898-W EP-34B Cured at normal temperature or by heating -55 to 200 Metals (Steel, stainless steel, copper, aluminum alloy, etc.) Plastics Composite materials PC-600 Cured by heating -269 to 250 Metals (Steel, stainless steel, copper, aluminum alloy, etc.) PI-32 Cured by heating -269 to 350 Metals (Steel, stainless steel, copper, aluminum alloy, etc.) 05

7 Load Cells Applications Compression Load Cell Compression Load Cell Network Terminal Box NTB-100B series Displacement measurement of plate bearing test Load control of press machines Instrumentation Amplifier WGA-900A Thin Load Cell "Multi Force Sensor" LCTA-A Compact 6-component Force Transducer LFM-A control of hoppers or tanks Instrumentation Amplifier WGA-900A Universal Recorder EDX-200A 6-component force measurement of an artificial leg or robot with built-in cells Small-sized Compression Load Cell LMA-A Small capacity LMA-A-5 to 50N Small-sized Compression Load Cell LMBT-A For high temperature (Up to100 C) LMBT-A-50 to 200N LMA-A-100N to 1KN 5 to 50 N 100 N to 1 kn 0.75 to 2 mv/v (5N: 0.6 to 2 mv/v) φ12 4 mm φ mm Approx. 1.5 g (Excluding cable) Approx. 11 g (Excluding cable) LMBT-A-500N to 2KN 50 to 200 N 500 N to 2 kn Within ±0.3% RO Within ±0.3% RO 1.4 mv/v or more φ10 4 mm φ16 7 mm Approx. 1.5 g (Excluding cable) Approx. 6.5 g (Excluding cable) *Case material 5 to 50 N: Copper alloy, 100 N to 1 kn: Stainless steel Small-sized Compression Load Cell LMB-A General-purpose LMB-A-10N to 200N Small-sized Compression Load Cell LMR-S-SA2 Large capacity LMB-A-500N to 2KN LMR-S-5KNSA2 10 to 200 N 500 N to 2 kn 1.4 mv/v or more (10N: 0.5 mv/v or more) φ10 4 mm φ16 7 mm Approx. 1.5 g (Excluding cable) Approx. 6 g (Excluding cable) 2 to 20 kn (20KNSA2: Within ±2% RO) (20KNSA2: Within ±2% RO) 1 mv/v or more Safe Overload 120% φ21 10 mm Approx. 25 g (Excluding cable) 06

8 Small-sized Compression Load Cell LMC-A Load distribution measurement using multiple units Load measurement of small press machines and pipe making mills 5 kn 10 kn 20 kn 50 kn 1.5 mv/v or more * (Excluding cable) Small-sized Compression Load Cell LCN-A Hermetically sealed structure with inert gas filled in 500 N to 20 kn Within ±0.15% RO Within ±0.1% RO 2 mv/v ±0.3% Safe Overload 200% φ50 25 mm Approx. 220 g (Excluding cable) *Main unit: SUS630, bottom plate: SUS304 Small-sized Compression Load Cell LCX-A-ID Degree of protection: IP67 Stainless steel enclosure LMC-A-5KN 10KN LCX-A-500N to 2KN-ID LMC-A-20KN LMC-A-50KN φ12 10 mm φ16 10 mm φ22 15 mm Approx. 5 g Approx. 6 g Approx. 10 g Approx. 30 g LCX-A-5 to 20KN-ID Small-sized Large-capacity Compression Load Cell LCR-G-SA2 Cable is connected at the bottom. Able to be used inside conduits. 10 to 30 kn 50 kn 1 mv/v or more Safe Overload 120% φ20 45 mm φ25 50 mm Approx. 100 g (Excluding cable) Approx. 130 g (Excluding cable) General-purpose Compression Load Cell LC-E Hermetically sealed structure with inert gas filled in 2 MN 5 MN Within ±0.2% RO 2 mv/v±1% φ mm φ mm Approx. 49 kg (Excluding cable) Approx. 65 kg (Excluding cable) High Temp. Compression Load Cell LC-FH Compensated temperature: -10 to 150 C (Excluding connector) 500 N to 2 kn 5 to 20 kn Within ±0.1% RO Within ±0.1% RO 1.5 mv/v or more (500 N: 1 mv/v or more) φ28 18 mm φ43 22 mm Approx. 45 g (Excluding cable) Approx. 120 g (Excluding cable) *Cable is connected by using a connector. Small-sized Compression Load Cell LC-V Cycling life: times or more Degree of protection: IP67 50 to 200 kn Within ±0.05% RO Within ±0.05% RO 2.5 mv/v ±0.2% φ68 40 mm to φ98 55 mm Approx. 1 to 3.1 kg (Excluding cable) 500 N to 200 kn 1.5 mv/v ±0.2% Safe Overload 200% Thickness: 25 mm (5 to 20 kn) Degree of protection: IP67 φ68 44 to φ mm Approx. 800 g to 7 kg (Excluding cable) Thin Compression Load Cell LCK-A 5 to 200 kn Within ±0.2% RO (200KN: ) Within ±0.2% RO (200KN: ) 2 mv/v ±0.5% φ78 25 mm to φ mm Approx. 700g to 3.5 kg (Excluding cable) Small-sized Compression Load Cell LCV-A Large output Cycling life: times or more 500 kn 1 MN Within ±0.1% RO Within ±0.1% RO 2.5 mv/v ±0.2% φ mm φ mm Approx. 6 kg (Excluding cable) Approx. 10 kg (Excluding cable) High-accuracy Compression Load Cell LCH-F Remote sensing Degree of protection: IP kn 200 kn Within ±0.02% RO Within ±0.02% RO 2 mv/v ±0.1% Safe Overload 200% φ mm φ mm Approx. 12 kg (Excluding cable) Approx. 17 kg (Excluding cable) 07

9 Explosion-proof Construction Compression Load Cell LCS-D Explosion-proof construction Thin Load Cell "Multi Force Sensor" LCTA-A Rubber attachment (option) provided. High precision, high reliability 5 to 50 kn Within ±0.2% RO Within ±0.2% RO 2 mv/v ±0.2% Safe Overload 120% Approx. 4 kg (Excluding cable) 500 N to 3 kn Within ±0.05% RO Within ±0.05% RO 2 mv/v ±0.2% Approx. 1.1 kg (Excluding cable) Corrosion-resistant Compression Load Cell LC-J Suitable for weighing in food processing or where they are exposed to liquid and gas. Thin Load Cell "Multi Force Sensor" LCTB-A Rubber attachment (option) provided. High precision, high reliability 5 to 200 kn 1 mv/v ±0.2% Safe Overload 400% Approx. 3 to 6 kg (Excluding cable) 5 to 50 kn Within ±0.03% RO Within ±0.03% RO 1.5 mv/v ±0.2% Approx. 1.8 to 5.3 kg (Excluding cable) Washer-type Load Cell LCW-C-SA3 Models of the same capacities are available with different diameters. Thin Load Cell "Multi Force Sensor" LCTE-A Rubber attachment (option) provided. High precision, high reliability 10 to 300 kn Approx. 1 mv/v Approx. 0.6 to 5.1 kg (Excluding cable) 10 to 100 kn Within ±0.05% RO (100KN: Within ±0.1% RO) Within ±0.05% RO (100KN: Within ±0.1% RO) 2 mv/v ±0.2% Approx. 3.2 to 7.2 kg (Excluding cable) Washer-type Load Cell LCW-D-S/E-S For measuring rolling mills. Heat and oil resistant cable LCW-E-S Thin Load Cell "Multi Force Sensor" LCTD-A Rubber attachment (option) provided. High precision, high reliability 1 to 5 MN 1 mv/v or more Approx. 7 to 20 kg (Excluding cable) *Rated capacity of more than 5 MN is able to be produced on order. 100 to 300 kn Within ±0.03% RO Within ±0.03% RO 2 mv/v ±0.2% Approx. 18 to 33 kg (Excluding cable) Stainless Steel Load Cell LCTS-B Built-in steady brace Degree of protection: IP67 High-accuracy Tension Load Cell LTZ-A Easy to use and maintain. Roberval mechanism LTZ-50 to 100KA LTZ-200KA to 2TA 5 to 100 kn Within ±0.05% RO Within ±0.05% RO 2 mv/v ±0.1% Approx.5 to 13 kg (Excluding cable) 500 N to 50 kn Within ±0.03% RO (500KA or larger: Within ±0.05% RO) Within ±0.03% RO (500KA or larger: Within ±0.05% RO) 3 mv/v ±0.2% Approx. 300 g to 4.4 kg (Excluding cable) 08

10 High/Low Temp. Tension Load Cell LT-FH/FL Compensated temperature: FH -10 to 150 C (Excluding connector) FL -196 to 30 C (Excluding connector) Ultimate overload: 500% 500 N to 50 kn 1.5 mv/v ±0.2% Safe Overload 200% Approx. 1.7 to 7 kg (Excluding cable) Tension/Compression Load Cell LUK-A Large capacity ±5 kn to ±2 MN Within ±0.1% RO (500KN or larger: Within ±0.2% RO) Within ±0.1% RO (500KN or larger: Within ±0.2% RO) 2 mv/v ±1% (5 to 20KN:2.4 mv/v ±10%) Approx. 900 g to 245 kg (Excluding cable) *Rated capacity of more than 2 MN is able to be produced on order. Compact Tension/Compression Load Cell LUX-B-ID Suitable for measuring load applied to small press machines and press-fitting devices. ±50 N to ±20 KN Within ±0.1% RO (2KN or smaller: Within ±0.15% RO) Within ±0.1% RO (2KN or smaller: Within ±0.15% RO) 1.3 mv/v or more (100N to 1KN: 0.9 mv/v or more, 50N: 0.85mV/V or more) Approx. 50 to 260 g (Excluding cable) Small-capacity Tension/Compression Load Cell LU-A Small capacity, high precision ±50 to ±200 N Within ±0.3% RO Within ±0.2% RO 1.5 mv/v ±0.5% Safe Overload 120% Approx. 2.3 kg (Excluding cable) Compact Tension/Compression Load Cell LUR-A-SA1 For wide range of applications. ±50 N to ±2 kn 0.5 mv/v or more (50NSA1: Approx. 0.4 mv/v) Approx. 70 g (Excluding cable) Ultra Small-capacity Load Cell LVS-A/LTS-A 2 types are available :LVS senses load in vertical direction to the mounting surface and LTS senses load in horizontal one. LVS: 50 mn to 20 N LTS: 500 mn to 20 N 1.5 mv/v or more (5GA, 10GA: 1.2 mv/v or more) Safe Overload 120% Approx. 50 g (Excluding cable) LVS-A Tension/Compression Load Cell LU-E Hermetically sealed structure with inert gas filled in Beam-type Load Cell LUB-B Corrosion-resistant (100KB to 2TB) LUB-5 to 50KB LUB-100KB to 2TB ±500 N to ±200 kn Within ±0.2% RO Within ±0.1% RO 2 mv/v ±0.2% Approx. 2.8 to 22 kg (Excluding cable) 50 N to 20 kn Within ±0.03% RO (100KB or larger: Within ±0.05% RO) Within ±0.03% RO (100KB or larger: Within ±0.05% RO) 2 mv/v ±0.3% Approx. 350 g to 2.8kg (Excluding cable) High-accuracy Tension/Compression Load Cell LUH-F Excellent zero-drift characteristic Remote sensing Beam-type Load Cell LUB-C Able to be used for measuring systems such as conveyors and tanks. ±500 N to ±200 kn Within ±0.02% RO Within ±0.02% RO 2 mv/v ±0.1% Approx. 2.1 to 38 kg (Excluding cable) 5, 20 kn Within ±0.05% RO Within ±0.05% RO 2 mv/v ±0.5% Approx. 1.3 to 2.7 kg (Excluding cable) 09

11 Compact 6-component Force Transducer LFM-A Measures 3-component force and 3-component moment. Refer to the table below. Refer to the table below. Refer to the table below. (Excluding cable) Compact 6-component Force Transducer with Built-in Amplifier LFX-A Built-in amplifier Measures 3-component force and 3-component moment. Refer to the table below. Approx mv (Compensated data)(at center with no-load) Model LFM-A-1KN LFM-A-3KN Fx : ±1000 N Fy : ±1000 N Fz : ±1000 N Mx: ±50 N m My: ±50 N m Mz: ±25 N m Fx : ±3000 N Fy : ±3000 N Fz : ±3000 N Mx: ±100 N m My: ±100 N m Mz: ±50 N m Refer to the table below. Fx :1.5 mv/v or more Fy :1.5 mv/v or more Fz :1.8 mv/v or more Mx:4.0 mv/v or more My:4.0 mv/v or more Mz :2.4 mv/v or more Fx :1.6 mv/v or more Fy :1.6 mv/v or more Fz :1.6 mv/v or more Mx:2.4 mv/v or more My:2.4 mv/v or more Mz:1.6 mv/v or more Approx. 160 g Approx. 360 g Crane Load Cell LTA-C-S Ultimate overload: Approx. 500% 20 to 500 kn 0.6 to 0.7 mv/v Approx. 5 to 60 kg (Excluding cable) One-end Revolving Tension Load Cell LTR-S-SA1 For measuring tensile force of ropes 20 to 50 kn Approx. 1 mv/v Approx. 3.6 kg (Excluding cable) Pin-type Load Cell LTP-S-S For measuring loads applied on the axis of a crane's pulley Specially designed for installation to pin connection Model LFX-A-1KN Fx : ±1000 N Fy : ±1000 N Fz : ±1000 N Mx:±40 N m My:±40 N m Mz:±25 N m Approx. 210 g 10 to 500 kn ±1% to 2% RO (Depends on user's spec.) ±1% to 2% RO (Depends on user's spec.) LFX-A-3KN Fx : ±3000 N Fy : ±3000 N Fz : ±3000 N Mx:±100 N m My:±100 N m Mz:±50 N m Approx. 420 g 0.5 to 1 mv/v Approx. 1.7 to 17.5 kg (Excluding cable) 3-component Force Transducer LSM-B-SA1 Measures 3-component moment. ±10 to ±500 N with all force components Fx, Fy and Fz Approx. 0.5 mv/v Approx. 600 g (Excluding cable) *LSM-B-500NSA1: Approx. 1.6 kg (Excluding cable) Rectangular Load Cell LCD-C For tension meters Compression application product (Tensile application product can also be manufactured.) 20 to 150 kn Within ±0.2% RO Within ±0.2% RO 0.8 mv/v or more Safe Overload 200% Approx. 31 to 47 kg (Excluding cable) Jack Load Cell LUR-B-SA1 Special design for jacks Tension Meter Load Cell LCR-B-S7 Available with 2 types of cable connection. ±10 kn to ±2 MN Within ±0.2% RO (300KNSA1 or larger: ) Within ±0.1% RO (300KNSA1 or larger: ) 1 mv/v ±1% Safe Overload 200 % Approx. 1.4 to 100 kg (Excluding cable) *If the capacity is more than 200 kn, the calibration is performed for compression load only. 5 to 100 kn Within ±0.1% RO (100KNS7: Within ±0.2% RO) Within ±0.1% RO (100KNS7: Within ±0.2% RO) 1 mv/v ±1% Safe Overload 300 % (100KNS7:200%) Approx. 4 to 19 kg (Excluding cable) *Stopper mechanism activates at overloads of 150 to 200%. 10

12 Pressure Transducers Applications Universal Recorder EDX-200A Small-sized High/Low-temperature Pressure Transducer PHL-A Small-sized Pressure Transducer PGL-A Hydraulic pressure control of construction machine Instrumentation Amplifier WGA-900A Refrigerant pressure monitor of air conditioning facilities High/Low-temperature Pressure Transducer Miniature Pressure Sensor PS Signal Conditioner CDV-900A Pressure measurement in pipes etc. Instrumentation Amplifier WGI-400A Usable as a touch sensor for built-in robot parts Small-sized Pressure Transducer PGL-A Pressure Transducer PG-U Semi-flush diaphragm type PGL-A-A Hermetically sealed structure with inert gas filled in 1 to 50 MPa Within ±0.3% RO (2MP or small: ) Within ±0.2% RO (2MP or small: ) 2 mv/v ±20% (2MP or small: ±30%) Mounting Screw G1/8, male Approx. 20 g (Excluding cable) 200 kpa to 50 MPa Within ±0.2% RO (2 to 10KU: Within ±0.3% RO) Within ±0.2% RO (2 to 10KU: Within ±0.3% RO) 2 mv/v ±0.5% (2 to 10KU: ±1%) Mounting Screw G3/8, male Approx. 300 g (2, 5KU: Approx. 500 g) (Excluding cable) *Cable integrated type is also available. *Material: SUS 630 (Liquid-contacting part) *Material: SUS 630 (Liquid-contacting part) Small-sized High/Low-temperature Pressure Transducer PHL-A Semi-flush diaphragm type Suitable for highly viscous heated fluids (melt resin), high-temperature gases and LPG/LNG tanks. Small-sized Pressure Transducer PGS-A Vibration resistant: m/s 2 (50G) Impact resistant: 4903 m/s 2 (500G) 1 to 50 MPa Within ±0.3% RO (2MP or small: ) Within ±0.2% RO (2MP or small: ) 2 mv/v ±20% (2MP or small: ±30%) Mounting Screw G1/8, male Approx. 20 g (Excluding cable) *Cable integrated type is also available. *Material: SUS 630 (Liquid-contacting part) 1 to 50 MPa Within ±0.2% RO (20KA: Within ±0.3% RO, 10KA: Within ±0.4% RO) Within ±0.2% RO 2 mv/v ±0.5% Mounting Screw G3/8, male Approx. 120 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) 11

13 High Pressure Transducer PG-H Hermetically sealed structure with inert gas filled in Small-sized Pressure Transducer PGMC-A Flush diaphragm type Sensing surface:φ , 200 MPa Within ±0.2% RO Within ±0.2% RO 1.5 mv/v ±0.5% Mounting Screw G1/2, male Approx. 220 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) 200 kpa to 1 MPa Within ±1.5% RO Within ±1.5% RO PGMC-A-200KP: 0.6 mv/v or more PGMC-A-500KP, 1MP: 1 mv/v ±20% Mounting Screw G1/8, male Approx. 20g (Excluding cable) *Material: C1720 (Liquid-contacting part) Small-sized Pressure Transducer PGM-H Semi-flush diaphragm type Small-sized Pressure Transducer PGM-D Flush diaphragm type 500 kpa to 50 MPa Within ±0.3% RO (5 to 20KH: ) Within ±0.2% RO 2 mv/v or more (5KH: 1.35 mv/v or more) Mounting Screw G3/8, male Approx. 65 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) 5 to 50 MPa 1.5 mv/v ±20% Mounting Screw G1/8, male Approx. 40 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) Small-sized Pressure Transducer PGM-E Flush diaphragm type 1 to 50 MPa 1 mv/v or more (500KE: 1.4 mv/v or more) Mounting Screw G3/8, male Approx. 65 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) High-pressure-resistant Pressure Transducer PGR-A For high temperature (Up to100 C) Ultimate overload: PGR-10 to 50KA 117.7MPa PGR-100, 200KA 196.1MPa 1 to 20 MPa Within ±0.1% RO Within ±0.1% RO 1.5 mv/v ±5% Safe Overload 300% Mounting Screw G3/8, male Approx. 400 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) Low Pressure Transducer PGM-G Flush diaphragm type Conduit pipe for back-pressure compensation can be integrated into the same cable. Absolute Pressure Transducer PAB-A Measures from absolute zero pressure. 20 to 100 kpa Within ±0.3% RO 02KG: 0.75 mv/v or more, 05KG: 1.25 mv/v or more 1KG: 1.4 mv/v or more Mounting Screw M14 P=1, male Approx. 40 g (Excluding cable) *Material: SUS 304 (Liquid-contacting part) 200 kpaabs. to 2 MPaabs. Within ±0.1% RO Within ±0.1% RO 2 mv/v or more Mounting Screw 7/16-20 UNF, male Approx. 130 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) 12

14 Highly Reliable Pressure Transducer (Sputter-gage type) PHS-B Long-term stable measurement at 200 C Enables absolute pressure measurement Small-sized High-temperature Pressure Transducer PHF-S-SA2 Compensated temperature: -40 to 150 C (Excluding connector) 200 kpaabs. to 20 MPaabs. Within ±0.2% RO Within ±0.2% RO 1.5 mv/v or more Mounting Screw G3/8, male Approx. 130 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) 2 to 20 MPa Within ±0.3% RO (2MPSA2: Within ±0.4% RO) Within ±0.2% RO Approx. 2 mv/v Mounting Screw R1/8, male Approx. 50 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) Flush Diaphragm Type High-temperature Pressure Transducer PHC-B Compensated temperature: 23 to 230 C (Excluding cable and connector) Small-sized High-temperature Pressure Transducer PHF-S-SA4 Compensated temperature: -40 to 150 C (Excluding connector) 2 to 20 MPa Within ±0.3% RO 0.6 mv/v or more Mounting Screw G1/8, male Approx. 70 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) 2 to 10 MPa Within ±0.3% RO Within ±0.2% RO Approx. 0.5 mv/v Mounting Screw 5/16-24UNF, male Approx. 20 g (Excluding cable and connector) *Material: SUS 630 (Liquid-contacting part) High/Low-temperature Pressure Transducer PHB-A Compensated temperature: -196 to 200 C (Excluding connector) Large-capacity Pressure Transducer PGH-S-100MPSA17 Safe design with just one SUS body without welded part. Removable cable Degree of protection: IP64 (After fitting connector) 1 to 50 MPa Within ±0.4% RO Within ±0.4% RO 2.2 mv/v ±15% Safe Overload 120% Mounting Screw G3/8, male Approx. 230 to 360 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) 100 MPa Within ±0.3% RO Within ±0.2% RO Approx. 1 mv/v Safe Excitation 10 V AC or DC Mounting Screw M12 P=1 Approx. 40 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) Small-sized High-temperature Pressure Transducer PHF-S-S1 series Can be installed in confined spaces. Tepmerature effect on zero: Within 0.008%RO/ C Compensated temperature: -40 to 150ºC Large-capacity Pressure Transducer PGH-S-SA19 Safe design with just one SUS body without welded part. Removable cable 2 to 20 MPa Within ±0.3%RO Within ±0.2% RO Approx mv/v Mounting Screw R1/8, M8 1.25, M , M10 1.0, 5/16-24UNF, G1/8 Approx. 20 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) Rated 材質は 本体 Capacity SUS 金属 接液部 250, 300 MPa SUS630 Within ±0.4%RO (250MPSA19: Within ±0.2%RO) Within ±0.4%RO (250MPSA19: Within ±0.2%RO) Approx. 0.5 mv/v Safe Excitation 10 V AC or DC Mounting Screw G1/2 Approx. 210 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) 13

15 Pressure Transducer PAV-R/U (Voltage output type) PAA-R/U (Current output type) With built-in amplifier and offers powerful resistance against transmission noise. S/N: 50 db or more PAV/PAA-R PAV/PAA-U Minute Differential Pressure Transducer PDS-A/PDV-A Quick response high precision, high sensitivity PDS-A PDV-A 1 to 50 MPa (PAV-R/U), 500 kpa to 50 MPa (PAA-R/U) Within ±0.2% RO Within ±0.2% RO Output PAV-R/U: 0 to 5 V PAA-R/U: 4 to 20 ma Safe Overload 200% Mounting Screw G3/8, male Approx. 200 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) 1 to 7 kpa (25GA: Within ±0.7% RO) Within ±0.3% RO PDS-A: 13 to 23 mv (10GA: 7 to 23 mv) PDV-A: 5 V Safe Overload 300% (10GA: 600%) PDS-A: Approx. 40 g PDV-A: Approx. 100 g (Excluding cable) Pressure Transducer PVL (Voltage output type) PAL (Current output type) S/N: 50 db or more 500 kpa to 50 MPa Within ±0.3% RO (5 to 20K: ) Within ±0.3% RO (5 to 20K: ) Output PVL: 0 to 5, 1 to 5 V PAL: 4 to 20 ma Mounting Screw G3/8, male Approx. 85 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) Highly Stable Current-output Pressure Transducer PAG-2KA Noise resistant S/N: 60 db or more PVL-A/B 200 kpa Within ±0.1% RO Within ±0.2% RO Output 4 to 20 ma Mounting Screw G3/8, male Approx. 270 g (Excluding cable) *Material: SUS 630 (Liquid-contacting part) PVL-C/D Differential Pressure Transducer PD-A Wide line pressure margin Max. line pressure: 2.94 MPa 10 to 200 kpa Within ±0.3% RO Within ±0.2% RO 1.5 mv/v ±1% Safe Overload Differential Pressure 200% (100, 200GA) 150% (500GA, 1KA) 125% (2KA) Approx. 5 kg (Excluding cable) Stainless Steel Differential Pressure Transducer PDU-A Max. line pressure: 30 MPa 50 kpa to 2 MPa Within ±0.2% RO (50KP to 500KP), within ±0.25%RO (1, 2MP) Within ±0.2% RO (50KP to 500KP), within ±0.25%RO (1, 2MP) 1.5 mv/v ±0.5% Safe Overload 150% (Withstand an overload of 30 MPa applied to either high or low pressure side.) Approx. 6 kg (Excluding cable) Miniature Pressure Sensor PS/PSS/PSM-AB For distributed pressure measurement Able to be attached with the dedicated adhesive. Flash diaphragm type is recommended for highspeed applications, high-viscosity compressive media and compressive media with risk of hardening. *Compression of solid materials cannot be measured. Semi-flush diaphragm type Flush diaphragm type 20 kpa to 7 MPa Within ±1% to ±3%RO Within ±1% to ±3%RO 0.25 to 1 mv/v (PS-70KC/D M2: 100%) Approx to 0.5 g (Excluding cable) *PS Type C: Flat type, type D: Umbrella type *PSS Type A: Flat type, type B: Umbrella type *PSM-AB Flat type only PGL-A Pressure inlet PGM-E 14

16 Acceleration Transducers Applications Small-sized Low Capacity Triaxial Accelerometer AMA-A Universal Recorder EDX-200A Small-sized High Frequency Response Acceleration Transducer ASH-A Memory Recorder/Analyzer EDX-5000A Vibration tests of goods during truck transportation Drop impact tests of fuel cell container and lithium-ion battery Strain Amplifier Small-sized Low Capacity Triaxial Accelerometer AMA-A Universal Recorder EDX-200A Vibration tests on railway vehicle and truck Accelerometer Vibration measurement of wheeled platforms Small-sized Small-capacity Acceleration Transducer AS-GA/GB Hermetic terminal type and cable integrated type Small-sized High Frequency Response Acceleration Transducer AS-HB Wide frequency response range AS-GA AS-GB Cable integrated type ±9.807 to ±196.1 m/s mv/v or more Safe Overload 300% Frequency Response DC to (40 to 250 Hz) Approx. 15 g (GA), approx. 25 g (GB) (Excluding cable) ±98.07 to ±490.3 m/s mv/v ±20% (10HB: ±25%) Safe Overload 300% Frequency Response DC to (500 Hz to 1.5 khz) Approx. 13 g (Excluding cable) Small-sized Acceleration Transducer AS-B Able to be attached easily using adhesive (CC-33A). Small-sized High Frequency Response Acceleration Transducer ASH-A Able to be attached easily using adhesive (CC-33A). ±98.07 to ±490.3 m/s mv/v ±20% (10B: ±25%) Safe Overload 300% Frequency Response DC to (350 to 1000 Hz) Approx. 13 g (Excluding cable) ±980.7 to ±9807 m/s mv/v ±20% Safe Overload 300% Frequency Response DC to (2 to 7 khz) Approx. 6.5 g (Excluding cable) 15

17 Small-sized Triaxial Acceleration Transducer AS-TG Measures acceleration synchronously in X, Y and Z directions. ±9.807 to ±196.1 m/s 2 Safe Overload Frequency Response Triaxial Acceleration Transducer AS-TB 0.5 mv/v or more 1000% (With stoppers) DC to (40 to 250 Hz) Approx. 110 g (Excluding cable) Measures acceleration synchronously in X, Y and Z directions. ±98.07 to ±490.3 m/s mv/v ±20% (10TB: ±25%) Safe Overload 300% (Each axis) Frequency Response DC to (350 Hz to 1 khz) Approx. 95 g (Excluding cable) Triaxial Acceleration Transducer ASHT-A Measures acceleration synchronously in X, Y and Z directions. Enables measurement from DC. Applicable to the analysis of acceleration in complex vibration phenomena ±980.7 to ±9807 m/s mv/v ±20% Safe Overload 300% Frequency Response DC to (1.2 to 5 khz) Approx. 45 g (Excluding cable) Waterproof Acceleration Transducer ASW-A Usable under both water and soil ±9.807 to ±196.1 m/s mv/v or more Safe Overload 300% Frequency Response DC to (40 to 250 Hz) Approx. 40 g (Excluding cable) *Hydraulic resistant: kpa Servo Type Acceleration Transducer/ASQ Dedicated Conditioner ASQ -D/VAQ -700A Servo Type Acceleration Transducer ASQ -D For slight vibration measurement ±9.807 to ±49.03 m/s 2 Within ±0.03% RO Within ±0.05% RO 5V (10 V) ±5% Frequency Response DC to 100 Hz Approx. 220 g (Excluding cable) ASQ Dedicated Conditioner VAQ -700A Measures acceleration, velocity and displacement simultaneously. Channels 1 (Multichannel configuration possible) Measuring Range Acceleration ±9.807 m/s 2 Output ±19.61 m/s 2 ±49.03 m/s 2 Velocity ±100, ±200, ±500 cm/s Displacement ±100, ±200, ±500 mm ±10 V (Load: 5 kω or more) mm Approx. 1.4 kg Piezoelectric Acceleration Transducer ASPA-A/ASPB-A/ASPC-A High sensitivity Broadbands High mechanical strength High environmental resistant ASPA-A-200 Used Acceleration ±2200 m/s 2 Voltage Sensitivity 1.0 mv per m/s 2 ±10% 15 to 25 VDC, 0.5 to 5.0 ma Approx. 2 g (Excluding cable) ASPB-A-200 Used Acceleration ±2200 m/s 2 Voltage Sensitivity 1.0 mv per m/s 2 ±10% 15 to 25 VDC, 0.5 to 5.0 ma Approx. 3 g (Excluding cable) ASPC-A-30 / -300 / -30-ID / -300-ID Used Acceleration ±360 to ±4000 m/s 2 Voltage Sensitivity 1.0 mv per m/s 2 ±10%, 10 mv per m/s 2 ±10% 21 to 24 VDC, 0.5 to 10 ma Approx. 11 g (Excluding cable) Small-sized Triaxial Accelerometer AMA-A Measures acceleration synchronously in X, Y and Z directions. External power supply is not necessary. Fault diagnosis function (AMA-A-2, 5) AMA-A-2: ±19.61 m/s 2 AMA-A-5: ±49.03 m/s 2 AMA-A-10-S1: ±98.07 m/s 2 2 V ±10% Safe Overload AMA-A-2, AMA-A-5: ±19613 m/s 2 Frequency Response ASPA-A AMA-A-10-S1: ±9807 m/s 2 AMA-A-2, AMA-A-5: DC to 500 Hz AMA-A-10-S1: DC to 200 Hz AMA-A-2, AMA-A-5: Approx. 3 g (Excluding cable) AMA-A-10-S1: Approx. 7 g (Excluding cable) Three Axis Angular Rate Gyro GSAT-A-900 External power supply is not necessary. Triaxial Suitable for posture measurement. ± rad/s Approx. 2.0 V Safe Overload 1000% Approx. 10 g (Excluding cable) ASPB-A AMA-A-2/5 AMA-A GSAT-A ASPC-A AMA-A-10-S1 AMA-A can be mounted on the top of a GSAT-A 16

18 Torque Transducers Applications Highly Rigid Torque Transducer TPH-A Torque Transducer Universal Recorder EDX-200A Torque measurement of wind power generators and dynamos Built-in Amplifier Torque Transducer TPS-A Strain Amplifier DPM-900 series Universal Recorder EDX-200A Torque measurement and control of stir machine when food is stirred Torque evaluation of motors Built-in Amplifier Torque Transducer TPS-A Built-in amplifier with ±5 V output Rotation speed output (4 pulses/rotation) Key-groove-free and supports friction fastening coupling as standard (excluding TPS-A-5KNM). Eliminates measurement error caused by key backlash. With slim 30 mm wide profile, TPS-A-01NM to 2NM can perform measurements while positioned side by side. ±0.1 N m to ±5 kn m Within ±0.1% RO (01NM to 2NM) Within ±0.3% RO (5NM to 5KNM) Within ±0.1% RO (01NM to 2NM) Within ±0.3% RO (5NM to 5KNM) 5 V ±4% (Load resistance 5 kω or more) (2 kω or more for 01NM to 2NM) 12±0.5 VDC (01NM to 2NM) 10 to 16 VDC (5NM to 5KNM) *When used with optional cable, TPS-A-01NM to 2NM support 24 VDC. TPS-A-01NM to 2NM TPS-A-500NM 1KNM TPS-A-5NM to 100NM TPS-A-5KNM 17 Model Current Consumption *1 Safe Overload TPS-A-01NM ±0.1 N m TPS-A-05NM ±0.5 N m 0.4 A or less 200% TPS-A-1NM ±1 N m TPS-A-2NM ±2 N m TPS-A-5NM ±5 N m 150% TPS-A-10NM ±10 N m TPS-A-50NM ±50 N m 120% 0.5 A or less TPS-A-100NM ±100 N m TPS-A-500NM ±500 N m 150% TPS-A-1KNM ±1 kn m TPS-A-5KNM ±5 kn m 0.4 A or less *1 (At 12 VDC) *2 Sensor only *3 Not rotating Cutoff Frequency of AMP 1.5 khz (-3 ±1 db) 200 Hz (-3 ±2 db) 500 Hz (-3 ±2 db) 550 Hz (-3 ±1 db) Max. Rotary Speed Safe Bending Moment *2 Safe Load at the Shaft End*3 Moment of Inertia (kg m 2 ) 1.0 N m rpm g 1.2 N m 300 N 5000 rpm 1.5 N m 3 N m 15 N m N kg 1.8 kg kg 150 N m 800 N 4000 rpm kg 3000 rpm 500 N m 1 kn kg

19 Highly Rigid Torque Transducer TPH-A High torsional stiffness Dedicated flexible coupling integrated. Easy to maintain. Extremely low noise. With dedicated built-in amplifier for direct simultaneous output of voltage and current. Able to measure torque and rotation speed at the same time. High-speed Torque Transducer TP-M Operating speed: 3000 to rpm Overload prevention stopper Recommends the carrier-type strain amplifiers DPM. Slip ring type ±500 N m to ±50 kn m Within ±0.2% RO (1TMA or larger: ) Within ±0.2% RO (1TMA or larger: ) 10V ±0.2% (Load resistance 10 kω or more) (1TMA or larger: ±10 V ±0.5%) 8mA ±1.25% (Load resistance 500 Ω or less) (1TMA or larger: 8 ma ±1.25%) (Minus rated capacity: 4 ma to zero: 12 ma to plus rated capacity: 20 ma) Cutoff Frequency of AMP 1 khz (Amplitude ratio at cutoff point -3 ± 2 db) (1TMA or larger: 120%) Max. Rotatory Speed Output is saturated at approx. 110% the rated capacity to rpm Approx to 100 kg *TPH-A series torque transducers are not cased, and thus, the rotating part and couplings are exposed. Considering fatigue failures of these parts, the user should consider installation of a safety steel cover, etc. Specially designed diaphragm couplings are incorporated into all transducers. The instruction manual describes the maximum safe misalignment from the shaft. For stable torque measurement, set the couplings to minimize misalignment. Small-sized Torque Transducer TP-D/E 0.2 to 5 N m Within ±0.2% RO Within ±0.2% RO 0.75 to 1.5 mv/v (stopper activates at 150%, Ultimate torque with a stopper 150% + 2 N m) Max. Rotary Speed rpm Approx. 1.1 kg Note: Worn brushes will be replaced for value. Non-rotary Type Torque Transducer TPR-S-10KNMSA48 Large capacity (±10kN m) Easily install with bolts on the flanges. For low-torque measurements Unique cantilever type detection mechanism Recommends the carrier-type strain amplifiers DPM. Slip ring type 0.2 to 2 N m 0.75 to 1.5 mv/v Safe Overload 120% Max. Rotatory Speed 4000 rpm TP-D: Approx. 560 g TP-E: Approx. 610 g *Without mounting legs (D), with mounting legs (E) Note: Worn brushes will be replaced for value. TP-E ±10 kn m Within ±0.3%RO Within ±0.3%RO Approx. 1.5 mv/v Safe Overload 120% Max. Rotary Speed Approx kg (Excluding cable) 18

20 Displacement Transducers Applications Inductance-type Displacement Transducesr DLT-AS Displacement Transducer DTH-A Strain Amplifier DPM-900 Series Displacement measurement of aseismic rubber used for seismically isolated structure in vibration test Memory Recorder/Analyzer EDX-5000A Deflection measurement in auto body strength test Displacement Transducer DTH-A Data Logger UCAM -60B Displacement measurement of plate load test Displacement Transducer DTH-A Network Terminal Box NTB-100 Series Deflection and displacement measurement of strength test of scaffold frames Displacement Transducer DTK-A For both tension and compression With a measuring scale Displacement Transducer DTS-A Quick response For both tension and compression Offers improved creep characteristics. 30, 50mm 100 mm Within ±0.3% RO Within ±0.3% RO Within ±0.3% RO Within ±0.3% RO 2.5 mv/v or more 2.5 mv/v±10% Measuring Force Approx. 2 N Measuring Force Approx. 5 N Displacement Transducer DTT-A For both tension and compression Offers improved creep characteristics. Potensionmeter type Displacement Transducer DTH-A High precision Large output Measuring Force 100 mm Within ±0.2% RO Within ±0.2% RO 0.9 V/V±10% Approx. 5 N 5 to 100 mm Within ±0.1% RO Within ±0.1% RO 5 mv/v ±0.1% (DTH-A-5: ±0.15%) Measuring Force Approx. 1.5 to 4 N 19

21 Displacement Transducer DTJ-A-200 For both tension and compression With a measuring scale Potentiometer-type Displacement Transducer DTP-D-S For large displacement measurement Service life: 10 4 times Safe Overload: 120% 200 mm Within ±0.3% RO Within ±0.3% RO 5 mv/v ±0.3% Measuring Force Approx. 5.9 N DTP-D-2KS DTP-D-5KS Displacement Transducer DT-A 2000, 5000 mm Within ±0.3% RO Within ±0.3% RO 5 mv/v ±0.3% Measuring Force Approx. 1 to 1.7 N *Adjustable fixed point models are also available. For both tension and compression With a measuring scale DT-50A DT-100A Inductance -type Displacement Transducer DLT-AS/BS DT-50A: 50 mm, DT-100A: 100 mm 1.5 mv/v ±20% Measuring Force Approx. 4.4 N Little friction and measuring force Recommends the carrier-type strain amplifiers DPM. (Carrier frequency: 5 khz) DLT-BS: Waterproof type DLT-AS Dial Gage-equipped Displacement Transducer DT-D With a direct-reading dial gage ±5 to ±500 mm Approx. 2 mv/v Measuring Force 10 to 50 mm 1.5 mv/v or more Approx. 1.7 to 2.7 N Clip-type Displacement Transducer DTC-A Potentiometer-type Displacement Transducer DTPA-A Sensor tips are designed in conformity with ASTM Standard. Mounting tips are optionally available. Safe Overload: 130% (With a stopper) DTC-A-5 Hardly kinking wire Quick response (1000 mm/s or equivalent) DTC-A-2 2, 5 mm 500, 1000 mm Within ±0.3% RO 2.5 mv/v (+20% to -10%) Within ±0.3% RO Measuring Force DTC-A-2: 4 to 20 N, DTC-A-5: 1 to 10 N 2.5 mv/v ±10% Measuring Force Approx. 2 N (Max. 2.8 N) 20

22 Dynamic Strain Amplifiers Applications Small-sized Torque Transducer TP-D/E Strain Amplifiers DPM-900 series Strain Gages KFGS Strain Amplifiers DPM-900 series Strength testing of seats Torque measurement of automotive components Strain Amplifier DPM-911B/912B/913B Simple operation vastly reduces the working hours. Carrier-wave amplifier with powerful noise-resistance. Strain Amplifier DPM-951A/952A Decrease the effects of inverter noises. Carrier-wave amplifier with powerful noise-resistance. DPM-911B DPM-912B DPM-913B DPM-951A DPM-952A Model Frequency Response S/N* DPM-911B DPM-912B DPM-913B DC to 2.5 khz DC to 5 khz DC to 10 khz *When set with bridge excitation=2 V rms, bridge resistance 120 Ω, LPF=FLAT, 1000 μm/m input, V output 60 dbp-p or more 57 dbp-p or more 53 dbp-p or more Model Frequency Response S/N* DPM-951A DPM-952A DC to 2 khz DC to 5 khz *When set with bridge excitation=2 V rms, bridge resistance 120 Ω, LPF=FLAT, 1000 μm/m input, V output 58 dbp-p or more 53 dbp-p or more 21 Channels 1 Channels 1 Measuring Target Strain (gages, transducers) Measuring Target Strain (gages, transducers) Within ±0.1%FS, within ±0.2%FS (913B) Within ±0.1% FS Output OUTPUT A: ±10 V (Load resistance 5 kω or more) OUTPUT B: ±10 V (Load resistance 5 kω or more) Output OUTPUT A: ±10 V (Load resistance 5 kω or more) OUTPUT B: ±10 V (Load resistance 5 kω or more) 100VAC, approx. 12 VA 10.5 to 15 VDC (Approx. 0.6 A: 12 VDC) 100VAC, approx. 12 VA 10.5 to 15 VDC (Approx. 0.6 A: 12 VDC) 49 x x mm (Excluding protrusions) 49 x x mm (Excluding protrusions) Approx. 1.2 kg Approx. 1.2 kg *115 VAC, 200 VAC and 230 VAC products can be manufactured. *115 VAC, 200 VAC and 230 VAC products can be manufactured.

23 Signal Conditioner CDV/CDA-900A CDV/CDA-900A-DC Multi Signal Conditioner MCF-A Quick response (DC to 500 khz) Long-distance measurement (up to 2 km) Performs all operations on the front panel Equips the same operability as the DPM-900 series Isolates each input/output of all conditioner cards MCF-8A Model CDV-900A CDA-900A CDV-900A CDA-900A Bridge Excitation Constant voltage Constant current MCF-16A Channels 1 Measuring Target Strain (gages, transducers), minute voltage Within ±0.01% FS Output OUTPUT A: ±10 V (Load resistance 5 kω or more) OUTPUT B: ±10 V (Load resistance 5 kω or more) 100 to 240 VAC, approx. 8 VA (100 VAC) 10.5 to 15 VDC, approx. 4 W (12 VDC) 49 x x mm (Excluding protrusions) Approx. 1.0 kg *CDV/CDA-900A-DC: DC power only Multi Signal Conditioner MCF-A Model MCF-8A (8 channels) MCF-16A (16 channels) 10 to 30 VDC x 101 x 170 mm (MCF-8A) (Excluding protrusions) 440 x 101 x 170 mm (MCF-16A) (Excluding protrusions) Approx. 5 kg (MCF-8A) Approx. 8 kg (MCA-16A) *With the DPM-91A mounted to every channel. DC Amplifier DA-710A Highly accurate 2-channel isolated DC amplifiers Input-output isolation ensures excellent stability and makes it less affect by noise. Strain Measuring Card DPM-91A (-I), DPM-92A (-I) Measuring Target Model DPM-91A DPM-91A-I DPM-92A DPM-92A-I Strain (gages, transducers) Within ±0.2% FS Frequency Response DC to 2.5 khz DC to 2.5 khz DC to 5 khz DC to 5 khz *5 V output to 200 μm/m input, 120 Ω short-circuited S/N* 49 db p-p 44 db p-p 45 db p-p 40 db p-p Reduction of Inverter Noise Yes Yes Signal Conditioner Card CDV-90A Measuring Target Frequency Response Strain (gages, transducers) DC to 50 khz (Deviation +0.5, -3 db) Within ±0.05% FS Channels 2 Input Mode Differential input, isolated between input and output, and between channels Frequency Response DC to 10 khz (+1, -3 db) Allowable Common Mode Voltage ±300 VDC or AC peak Insulation resistance 1000 MΩ or more Allowable Max. Input Voltage ±2 VDC or AC peak (ATT 1) ±110 VDC or AC peak (ATT 1/100) Within ±0.05% FS Output OUTPUT A: ±10 V (Load resistance 10 kω or more) OUTPUT B: ±10 V (Load resistance 10 kω or more) 100 VAC, approx. 4.5 VA 49 x x mm (Excluding protrusions) Approx. 1.0 kg Thermocouple Card CTA-90A Applicable Thermocouple K, T, J, N, E, R (Thermocouple resistant: 1 kω or less) Linearizer Accuracy Within ±0.5% FS (K, J, N, E, R) Within ±1%FS (T) 22

24 Compact Signal Conditioner CDV-400B series Compact and lightweight, suitable for on-vehicle and mobile applications. CDV-458B Channels 6, 8, 14 Optional Unit Signal Conditioner Unit CV-10B, 11B (Strain measurement) LPF Module LFU-10B (2nd order LPF) Potentiometer Unit CPT-11B F/V Converter Module CFV-11B (Square wave frequency measurement) 11 to 30 VDC 100 VAC: Use the optional AC adapter SA-6A. (Except for the CDV-464B) See table below. See table below. Model CDV-456B CDV-458B CDV-464B (Excluding protrusions) mm mm mm Unit Base Only 490 g 530 g 880 g (Approx.) With full units of CV-11B 880 g 1 kg 1.8 kg Housing Case YC-A (For DPM-900 series, CDV-900A, CDA-900A, VAQ-700A, DA-710A) Can perform simultaneous measurements of multiple products. Batch balance and calibration. YC-8A Model Power Supply Housing Units (Excluding protrusions) YC-3A YC-3A-AC/DC YC-4A YC-4A-AC/DC YC-6A YC-6A-AC/DC YC-8A YC-8A-AC/DC AC AC/DC AC AC/DC AC AC/DC AC AC/DC mm mm mm mm 23

25 Data Loggers Applications Strain Gages Strain Gages CAN/USB Converter Displacement Transducer Network Terminal Box NTB-100B Static load-carrying testing Displacement Transducer Load Cell CAN/USB Converter Medium Speed Network Terminal Box NTB-500A Medium Speed Network Terminal Box NTB-500A Strain Gages CAN/USB Converter Evaluation testing of secondary concrete products Stress evaluation of auto components and the strength testing of automotive bodies Data Logger UCAM -60B/65B TEDS-compatible (Dedicated Scanner USS-61B/62B/63B) Up to μm/m with a resolution of 0.1 μm/m. DC-operated models are for operation where no AC outlet is available. Automatic reading of gage modes and a setup are possible. Configuration Dedicated scanners (mounted to the UCAM): USS-61B (TEDS compatible) USS-62B (With NDIS connectors, TEDS compatible) USS-63B (For civil engineering measurement, TEDS compatible, with lightning arresters) *Single dedicated scanner measures 10 channels. Max. 3 units are able to be mounted to the UCAM. External scanners USB-70 series (USI-67A) Scanner interfaces USI-67A for USB-70 series/65a UCAM -60B UCAM -65B UCAM -60B Built-in thermal printer for immediate confirmation of measured results UCAM -65B Setting measuring conditions from PC and saving measured results in PC Interval measurement possible with no PC connected Channels Max. 30 Max. 1000: When connecting external scanners Measuring Target Strain (gages, transducers), civil engineering transducers, voltage, current, temperature (thermocouples), temperature (platinum-resistance thermometer sensors), potentiometer sensors Measuring Range Strain: Max μm/m Voltage: Max. ± V Current: Max. ±50.00 ma (External shunt resistor is required.) Thermocouples: K, T, E, J, and R Temperature measurement with civil engineering transducers: Max C Platinum-resistance thermometer sensors: Pt100 and JPt100 Potentiometer sensors: Max. ±50.00% Scanning Speed 50 ms/channel (Standard mode) 280 ms/channel (High-resolution mode) *Full-bridge system *Individually switchable for desired channels. 20 ms/channel (High-speed mode) *Full-bridge system *Collectively switchable for all channels of dedicated scanners. Storage Saves the measured data in the built-in memory or flash ATA card. 100 to 240 VAC (AC-operated model) 10 to 16 VDC (DC-operated model) DC-operated model has power control function. 360 x 88 x 400 mm (Excluding protrusions) (60B) 327 x 88 x 365 mm (Excluding protrusions) (65B) Approx. 6.3 kg (60B), approx. 5 kg (65B) (Excluding scanner) 24

26 Control Software UCS-60B Displays numeric data on tables. Displays max. 50 graph windows (20-channel data per window). Fast Data Logger UCAM -550A Performs standalone measurement of static to dynamic phenomena. Synchronous sampling of all channels (*Excluding the temperature measurement mode of the USM-51B/52B.) Measures 1000 channels at max. 50 Hz. OS Display Windows Vista, Windows 7, 8/8.1, Japanese/English 32/64 bits support or more PC is not included. Data Monitor Windows Bar Graph Window Channels Measuring Target Measuring Range Sampling Frequency Storage Max. 50 channels/unit (Possible up to 5 units of the measuring unit) (Each measuring unit measures 10 channels.) Measures max channels by executing the synchronous operation by using multiple units. *DCS-106A corresponds up to 20 units (Max channels). *DCS-100A corresponds up to 6 units (Max. 300 channels). Strain (gages, transducers), voltage, temperature (thermocouples), potentiometer sensors Refer to each unit below. 1, 2, 10, 20, 50 Hz Measured data is stored on the PC (No internal storage) 100 to 240 VAC Approx. 50VA (With 5 units of USS-51B installed) mm (Excluding protrusions) Approx. 7 kg (With 5 units of USS-51B installed) Data Reproduce Window X-Y Graph Numeric Window Dedicated Optional accessories Strain/Voltage/Thermocouple Unit USM-51B/52B Channels 10 Measuring Target Strain (gages, transducers), voltage, temperature (thermocouples K, T, E, J, R, N), Potentiometer sensors Measuring Range Strain Max. ± μm/m Strain Unit USS-51B Voltage Max. ±20 V Temperature Max ºC Potentiometer sensors Max. ±50% Channels 10 Measuring Target Strain (gages, transducers), Potentiometer sensors Measuring Range Max. ± μm/m Voltage Unit USV-51B Channels 10 Measuring Target Voltage Measuring Range Max. ±20 V Thermocouple Unit UST-51B Channels 10 Measuring Target Temperature (Thermocouples K, T, E, J, R, N) Measuring Range Max ºC 25

27 Medium Speed Network Terminal Box NTB-500A One-wire distributed arrangement Measures all channels synchronously at max. 1 khz. Network Terminal Box NTB-100/200 series NTB-100A series Using just a single wire, measurements are able to be performed in extensively dispersed deployments (up to the length of 1 km). With NTB-10A software, measurements are able to be performed immediately. NTB-100B-120 Channels Measuring Target Measuring Range Sampling Frequency Cable Length Bridge Excitation Storage Max. 8/unit Max. 2 measuring units (4 channels/unit) are available. Refer to each unit below. Refer to each unit below. Max. 1 khz Cable total extension: Max. 100 m 2 VDC±1% Measured data is stored on the PC (No internal storage). 11 to 16 VDC mm (Excluding protrusions) Approx. 490 g *A CAN/USB converter and a termination resistor are required. *Combination with NTB-100/200 series is not available. Strain Unit NTB-50A Built-in bridge circuits Channels 4 Measuring Target Strain (gages, transducers) Measuring Range Max. 300k μm/m Frequency Response DC to 100 Hz Voltage/Thermocouple Unit NTB-51A Isolated among channels Channels 4 Measuring Target Voltage, thermocouples (K, T) Measuring Range Max. 50 V Frequency Response DC to 100 Hz (voltage)/dc to 10 Hz (thermocouples) NTB-101A-350 Network Terminal Box models Model Bridge Excitation Sensor Input Terminals Gage NTB-100B-120 Constant-voltage One-touch terminal 120 Ω NTB-101A-120 Constant-voltage Screw soldering terminal 120 Ω NTB-100B-350 Constant-voltage One-touch terminal 350 Ω NTB-101A-350 Constant-voltage Screw soldering terminal 350 Ω NTB-110B-350 Constant-current One-touch terminal (For full bridge) NTB-111A-350 Constant-current Screw soldering terminal (For full bridge) *Control software NTB-10A is a standard accessory. No control software for models with suffix -0. Channels 4 Measuring Target Strain (gages, transducers), civil engineering transducers Measuring Range Strain 0 to ± μm/m (Constant-voltage bridge excitation) 0 to ± μm/m (Constant-current bridge excitation) Temperature (Civil engineering transducer with a thermal sensor) to 70.0 C Scanning Speed Approx. 0.5 s per channel: 0 to ± μm/m Approx. 1 s per channel: ± μm/m or more Approx. 1 s per channel: Civil engineering transducer with thermal sensor Cable Length Cable total extension: Max m Bridge Excitation Constant-voltage bridge excitation: Approx. 2 VDC Constant-current bridge excitation: Approx. 5.6 ma Storage (Bridge resistance 350 Ω) Measurement data is saved in the PC (No internal storage). 11 to 16 VDC One-touch terminal model mm (Excluding protrusions) Screw soldering model mm (Excluding protrusions) One-touch terminal model Approx. 310 g Screw soldering model Approx. 650 g *A CAN/USB converter and a termination resistor are required. *Combination with NTB-500A is not available. Voltage/Thermocouple Measurement Network Terminal Box NTB-201A NTB-201A Channels 4 Measuring Target Voltage, thermocouples (K, T, E, J, R, N) Scanning Speed Approx. 0.5 s/channel Measuring Range Max. 50 V 11 to 16 VDC mm (Excluding protrusions) Approx. 320 g 26

28 NTB Box NTB-20A NTB Relay Box NTB-21A Combines power line and communication line into the same cable for dispersed deployments in areas without power such as in outdoor installations. NTB-20A NTB-21A Network Terminal Box Control Software NTB-10A Supports graph display and numerical display of measurement data from PC. Handy Data Logger SME-30A/31A/100A/101A Saves the measured data in a SD card. Built-in bridge circuit Network Terminal Box enables multi-channel measurement (SME-100A/101A). SME series SME-100A Model SME-30A SME-31A SME-100A SME-101A Measurement with the NTB Yes Yes Usage of AC adapter Yes Yes Measurement with the SMET-1A Yes Yes Yes Yes Channels 1 Measuring Target Strain (gages, transducers), civil engineering transducers with a thermal sensor Measuring Range Strain 0 to ± μm/m (Constant-voltage bridge excitation) 0 to ± μm/m (Constant-current bridge excitation) Temperature (Civil engineering transducers with a thermal sensor) C to 70.0 C Sampling Period Approx. 0.5 s (0 to ± μm/m) Approx. 1 s (± μm/m or more) Approx. 1 s (Civil engineering transducers with a thermal sensor) Bridge Excitation Constant-voltage bridge excitation: Approx. 2 VDC Constant-current bridge excitation: Approx. 5.6 ma (Bridge resistance 350 Ω) Interval Measurement Operating Temperature and Humidity Range 1 minute to 99 hours 59 minutes in 1-minute steps -10 to 50 C 20 to 85% RH (Non-condensing) AA size alkaline battery mm (Excluding protrusions) Approx. 450 g (Excluding batteries) SME Thermocouple Adapter SMET-1A Measures temperature using thermocouple when attached to SME series. 27 Measuring Target Thermocouples (K, T) Input Applicable wires Single wires: UL AWG 14 to 28 Twisted wires: UL AWG 20 to 24

29 Data Recorders/ Data Analyzers Applications Built-in Amplifier Torque Transducer TPS Sensor Interface PCD-430A Durability testing of automotive components Camera Strain Gages Compact Recording System EDX-10 Series Acceleration Transducer Strain Gages PC Memory Recorder/Analyzer EDX-5000A Strain measurements during lifted transport Drop Testing of Mobile Phones and Tablet PCs Compact Recording System EDX-10 series With stacked connection, no sync cable is required, therefore wiring-saving. Simple connection using USB interface Simple data monitoring and collection by using the standard accessory Dynamic Data Acquisition Software DCS-100A Max. 4 measuring units (16 channels) can be powered by USB interface. (Depending on configurations.) Control Unit EDX-10B Interface USB2.0 compliant Connective Measuring Units Max. 4 (16 channels) Sampling Frequency 1 Hz to 20 khz (1 to 4 channels) 1 Hz to 10 khz (1 to 8 channels) 1 Hz to 5 khz (1 to 16 channels) Current Consumption 140 ma or less (5 VDC) 5 VDC mm (Excluding protrusions) Approx. 170 g Strain Measuring Unit EDX-11A Channels 4 Measuring Target Strain (gages, transducers) Measuring Range 10000, µm/m Within ±0.1%FS A/D Converter 24 bits Frequency Response DC to 2 khz Bridge Excitation 2 VDC Current Consumption 180 ma or less (120 Ω load with all channels connected, at power supply 5 VDC) 5 VDC supplied by control unit mm (Excluding protrusions) Approx. 150 g 28

30 Voltage Measuring Unit EDX-12A Channels 4 (Single-end) Measuring Target Voltage Measuring Range 10 V, 50 V (2 ranges) Within ±0.1%FS A/D Converter 24 bits Frequency Response DC to 2 khz Current Consumption 110 ma or less (5 VDC) 5 VDC supplied by control unit mm (Excluding protrusions) Approx. 150 g Universal Recorder EDX-200A Supports offline measurements. High-speed sampling of 10 khz across all channels (in 32-channel mode). Measures 3 channels simultaneously at max. 100 khz. Built-in real-time digital filters 8th digital filter enables to acquire clear waveform. High-speed/low-speed dual sampling Measures high-speed and low-speed phenomena while reducing data quantities. One-wire synchronous (Excluding EDX-200A-1) With a maximum of 8 units using dispersion, support for large-scale measurements possible. Variety of optional input conditioner cards Usable under high/low-temperature environments (EDX-200A-4T only) (-20 to 65 C) Thermocouple Measuring Unit EDX-13A Channels 4 Measuring Target Thermocouples Measuring Range K: -200 to 1370 C T: -200 to 400 C J : -200 to 1200 C N: -200 to 1300 C A/D Converter 24 bits EDX-200A-1 EDX-200A-2H EDX-200A-4H EDX-200A-4T Sampling System Scanning Current Consumption 120 ma or less (5 VDC) 5 VDC supplied by control unit mm (Excluding protrusions) Approx. 130 g Low-power Strain Measuring Unit EDX-14A Channels 4 Measuring Target Strain (gages, transducers) Measuring Range 10000, µm/m (2 ranges) Within ±0.1%FS A/D Converter 24 bits Frequency Response DC to 2 khz Current Consumption 140 ma or less (120 Ω load with all channels connected, at power supply 5 VDC) 5 VDC supplied by control unit mm (Excluding protrusions) Approx. 150 g *Bridge excitation: 1 VDC Strain/Voltage Measuring Unit EDX-15A Channels 4 Measuring Target Strain (gages, transducers) Voltage (Single-end) Measuring Range 10000, µm/m (2 ranges) 10, 50 V Within ±0.1%FS A/D Converter 24 bits Frequency Response DC to 2 khz Current Consumption 150 ma or less (120 Ω load with all channels connected, at power supply 5 VDC) 5 VDC supplied by control unit mm (Excluding protrusions) Approx. 150 g *Bridge excitation: 1 VDC Model Channels Card Slots Optional Slots EDX-200A-1 EDX-200A-2H EDX-200A-4H EDX-200A-4T *Channels: When 8-channel input cards are inserted. Channels Max. 32 (analog) Measuring Target Strain (gages, transducers), voltage, thermocouples, pulse, piezoelectric acceleration (built-in amplifier), CAN signals *EDX-200A-4T accepts only CVM-41A, CDV-40B, CDV-40B-F, and CAN-41A for which temperature expansion measures are taken. Measuring Range Refer to conditioner cards. Sampling Frequency Max. 100 khz Measuring Mode Manual, interval, and trigger measurement *Trigger measurement is not available with CAN data. 10 to 36 VDC (EDX-200A-1: 10 to 33 VDC) Connector type: RM12BRD-4PH (Hirose) Use DC power supply or AC adapter (Optional accessory) Impact Resistant m/s 2 (20 G)/11 ms Current Consumption EDX-200A-1 Approx. 1.0 A (12 VDC, when CDV-40B 1 installed) EDX-200A-2H Approx. 1.6 A (12 VDC, when CDV-40B 2 installed) EDX-200A-4H/4T Approx. 2.6 A (12 VDC, when CDV-40B 4 installed) EDX-200A mm (Excluding protrusions) EDX-200A-2H mm (Excluding protrusions) EDX-200A-4H mm (Excluding protrusions) EDX-200A-4T mm (Excluding protrusions) EDX-200A-1 Approx. 0.9 kg EDX-200A-2H Approx. 1.8 kg EDX-200A-4H Approx. 2.1 kg EDX-200A-4T Approx. 3.7 kg

31 EDX-200A-2H/4H/4T Option Cards Optional cards 8 bits digital I/O Measures CAN data or GPS information without reducing the number of analog channels. No drop in analog-channel sampling frequencies Universal Recorder EDX-100A High-speed sampling at 100 khz (10 khz for 16-channel measurement) LAN port for establishing multichannel network (Max. 256 channels) USB port for easy connection Dynamic Data Acquisition Software DCS-100A is included as a standard accessory. Variety of optional input conditioner cards ECAN-40A ETIM-40A EGPC-40A Multichannel CAN Card ECAN-40A Outputs CAN data. For EDX-200A-4T, please use ECAN-40AM72. CAN Ports Channels Supported CAN Version Digital I/O *Standard Accessories Option software for DCS-100A: DCS-105A Connector plug for digital I/O ports, shell case: 1 piece each Time Synchronization Card ETIM-40A Enables synchronized interval measurement between remotely-placed EDX-200A units by receiving clock data from GPS satellite. For EDX-200A-4T, please use ETIM-40AM72. Digital I/O *Standard Accessories GPS sensor (Cable length: 5 m) Connector plug for digital I/O ports, shell case: 1 piece each GPS/Multichannel CAN Card EGPC-40A Acquires GPS & CAN data (Max. 512 channels) simultaneously. Acquires data without using a PC. For EDX-200A-4T, please use EGPC-40AM72. Digital I/O 2 (Selection of low speed or high speed is possible in each port) Max. 512 (2 ports) Compatible with CAN 2.0A/B (ISO-11898, ISO compliant) I/O Points Max. 8 Input Voltage Max. 5 VDC Output Voltage 5 VDC Output Current Max. 25 ma (per point) I/O Points Max. 8 Input Voltage Max. 5 VDC Output Voltage 5 VDC Output Current Max. 25 ma (per point) Channels Max. 512 Supported CAN Version Compatible with CAN 2.0A/B (ISO-11898, ISO compliant) I/O Points Max. 8 Input Voltage Max. 5 VDC Output Voltage 5 VDC Output Current Max. 25 ma (per point) *Standard Accessories GPS sensor (Cable length: 5 m) Option software for DCS-100A: DCS-105A Connector plug for digital I/O ports, shell case: 1 piece each *Card Slots: The number of slots for conditioner cards. Channels Measuring Target Measuring Range Sampling Frequency Measuring Mode Impact Resistant Current Consumption Able to be deployed dispersively for simultaneous measurement using multiple number of EDX-100A units. Able to be used straightaway when connected to EDX. (ESYN-30A power supply provided by EDX) Monitor Unit EMON-20A Monitors any 8-channel data Controls the EDX-100A/200A via the touch panel. Setting channel conditions Applicable Recorder Model EDX-100A-1 EDX-100A-2 EDX-100A-4 Optional Accessories Max. 32 (analog) Strain (gages, transducers), voltage, thermocouples, pulse, piezoelectric acceleration (built-in amplifier), CAN signals Refer to conditioner cards. Max. 100 khz Manual, interval, and trigger measurement *Trigger measurement is not available with CAN data. 10 to 18 VDC Connector type: RM12BRD-4PH (Hirose) Use DC power supply or AC adapter (Optional accessory) m/s 2 (20 G)/11 ms EDX-100A-1 Approx. 1.2 A (12 VDC, when CDV-40B 1 installed) EDX-100A-2 Approx. 1.8 A (12 VDC, when CDV-40B 2 installed) EDX-100A-4 Approx. 2.8 A (12 VDC, when CDV-40B 4 installed) EDX-100A mm (Excluding protrusions) EDX-100A mm (Excluding protrusions) EDX-100A mm (Excluding protrusions) EDX-100A-1 Approx. 1.6 kg EDX-100A-2 Approx. 1.8 kg EDX-100A-4 Approx. 2.0 kg Synchronous Extension Unit Channels ESYN-30A EDX-100A/200A (Max. 3 units in sync) Display LCD: 5.7" color TFT, 320 x 240 Touch panel: Analog resistance membrane Power LED: Lights up (Power ON) Display Content Y-time graph, numeric monitoring 10 to 36 VDC or a dedicated AC adapter Impact Resistant 147.0m/s 2 (15G)/11ms Other Function Language selection (Japanese/English), backlight (ON/OFF, lighting time), operating beeps Card Slots

32 Memory Recorder/Analyzer EDX-5000A High-speed sampling at 200 khz/32 channels Records the measuring data and video simultaneously. Variety of optional input conditioner cards Offers outstanding operation with touch panel and dedicated software. Effective real-time processing capability Conditioner Cards for EDX-100A, EDX-200A, EDX-5000A Strain/Voltage Measurement Card CDV-40B/CDV-40B-F Measurement card for measuring strain (gages, transuducers) and voltage. *Type with antialiasing filters is the CDV-40B-F. EDX-5000A-64 EDX-5000A-80 Strain Voltage Measuring Target Strain (gages, transducers), voltage Channels 8 (Centralized connector) Balance Adjustment ±2.4% (±12000 μm/m) Measuring Range Max. 50 k μm/m Max. 10 V ±0.1%FS Frequency Response DC to 50 khz Antialiasing LPF (CDV-40B-F only) Transfer characteristic: 8th order Butterworth Model Channels Card slots Storage Language EDX-5000A-64-H EDX-5000A-64-HE EDX-5000A-64-S EDX-5000A-64-SE EDX-5000A-80-H EDX-5000A-80-HE EDX-5000A-80-S EDX-5000A-80-SE HDD HDD SSD SSD HDD HDD SSD SSD Japanese English Japanese English Japanese English Japanese English Strain/Voltage Measurement Isolation Card CDV-44AS Measurement card against common mode noise even in workplaces with power machinery. Channels Measuring Target Measuring Range Sampling Frequency Measuring Mode Impact Resistant Current Consumption 64, 80 (analog) Strain (gages, transducers), voltage, thermocouples, pulse, piezoelectric acceleration (built-in amplifier), CAN signals Refer to conditioner cards. Max. 200 khz Manual, interval, and trigger measurement 100 to 240 VAC and 10 to 30 VDC, dual supply Built-in batteries against momentary power failure m/s 2 (20 G)/ 11 ms EDX-5000A-64 Approx. 1.8 A (100 VAC, when CDV-40B x 8 installed) EDX-5000A-80 Approx. 2.0 A (100 VAC, when CDV-40B x 10 installed) EDX-5000A mm (Excluding protrusions) EDX-5000A mm (Excluding protrusions) EDX-5000A-64 Approx kg EDX-5000A-80 Approx kg Measuring Target Strain (gages, transducers), voltage Channels 4 Frequency Response DC to 5 khz Measuring Range Max. 20 k μm/m (Strain mode) Max. 50 V (Voltage mode) Within ±0.1%FS Monitor Output Accuracy: Within ±5 V±0.5% Withstand Voltage Between input and case (output): 500 VDC, 1 min. Between channel: 500 VDC, 1 min. Constant Current Amplifier Card CDA-44AS/45AS Optional Accessories GPS/Multichannel CAN Module EGPC-50A Channels Max. 512 Supported CAN Version Compatible with CAN 2.0A/B (ISO-11898, ISO compliant) GPS Data Latitude, longitude, elevation, course over ground, speed, time, receiving conditions, the number of satellites in use, etc. Saving format: NMEA format Synchronization Synchronizes the recording start time of EDX-5000A units by using the time data received from GPS stellites. *Standard Accessories GPS sensor (Cable length: 5 m) *Please contact Kyowa or our representatives for attaching the EGPC-50A. Measurement card suitable for cable extension. CDA-44AS Measuring Target Strain (gages, transducers), voltage Channels 4 Frequency Response DC to 200 Hz Measuring Range Max. 20 k μm/m (Strain mode) Max. 50 V (Voltage mode) Within ±0.1%FS Monitor Output Accuracy: Within ±5 V±0.5% Withstand Voltage Between input and case (output): 500 VDC, 1 min. Between channels: 500 VDC, 1 min. 31

33 Strain/Voltage/Acceleration Measurement Card CVM-41A High resolution conditioner card for measuring strain sensors, voltage sensors, and acceleration sensors (built-in amplifiers). F/V Converter Card CFV-40A Converter card for measuring frequency of an input pulse. Measuring Target Channels 8 Bridge Excitation to Sensor Strain Strain gages Strain-gage transducers BV 2V: 2 VDC BV 5V: 5 VDC BV 10V: 10 VDC Voltage Voltage 2 VDC (±1 V) 5 VDC (±2.5 V) 10 VDC (±5 V) Acceleration Piezoresistive accelerometers (Built-in amplifier) Excitation Voltage: Approx. 23 V DC Measuring Range Max. 500 k μm/m Max. 50 V Max mv Within ±0.1%FS Within ±0.2%FS Frequency Response DC coupling: DC to 5 khz AC coupling: 0.2, 1 Hz to 5 khz 0.5 Hz to 5 khz LPF Transfer characteristic: 5th order Butterworth Monitor Output Accuracy: Within ±5 V ±0.5% (at ±FS) Measuring Target Alternating signal output sensors Channels 4 Input Signal AC (Zero cross), TTL level (Including open collector signals) Input Voltage ±(0.5 V to 50 V): High hysteresis ±(0.1 V to 50 V): Low hysteresis Measuring Range Max. 20 khz to Sensor 12 VDC: Within ±10% (50 ma or less, each channel) Monitor Output Accuracy: Within 5 V±0.5% (at +FS) Insulation Between input and output, and between channels: 500 VDC, 50 MΩ or more Charge Amplifier Card CCA-40A/CCA-40A-F Conditioner card for the piezoresistive accelerometers. *Type with antialiasing filters is the CCA-40A-F. Dynamic Strain Measurement Card DPM-42B Carrier wave type card for measuring low level strain. It is isolated between input and output, and among channels. *Type with antialiasing filters is the DPM-42B-F and DPM-42B-I-F. *Type with against inverter noise is the DPM-42B-I and DPM-42B-I-F. CCA-40A Measuring Target Piezoresistive accelerometers Applicable Accelerometer Built-in amplifiers (Voltage output) Channels 8 to Sensor Constant current output (Constant current: 4 ma, bridge excitation: Approx. 24 VDC, load: 1 kω or less) Frequency Response 1 to 20 khz Measuring Range Max mv Antialiasing LPF (CCA-40A-F only) Transfer characteristic: 8th order Butterworth Distortion Factor 1% or less Monitor Output Accuracy: Within ±5 V±1% (at +FS) Measuring Target Strain (gages, transducers) Channels 4 Frequency Response DC to 5 khz (Deviation: ±10%) Balance Adjustment : ±2.4% (±12000 μm/m) Capacity: 2000 pf Measuring Range Max μm/m Within ±0.2%FS Antialiasing LPF (DPM-42B-F, DPM-42B-I-F) Transfer characteristic: 8th order Butterworth Monitor Output Accuracy: Within ±5 V±0.5% (at ±FS) Withstand Voltage Between input and output: 250 VAC, 1 min. Thermocouple Card CTA-40A Temperature measurement card for thermocouples, K (CA) and T (CC). CAN card CAN-41A Measurement card for measuring CAN data. CAN-41A CAN Ports 2 (2 nodes) Supported CAN Version Compatible with Bosh 2.0B active (ISO compliant) High-speed CAN, low-speed CAN Measuring ID Numbers Max. 32 Graph Display Simultaneous graph display of numerical value, frame, and analog data *Not available with the EDX-5000A. CT-2A CTA-40A Measuring Target Thermocouples Channels 8 Applicable Thermocouple K (CA), T (CC) General Accuracy Ambient temperature 20±3 C Within ±(0.5% of reading+1) C Ambient temperature 0 to 40 C Within ±(0.5% of reading+2) C Frequency Response DC to 10 Hz Monitor Output Accuracy: Within 5 V±0.5% (at+fs) *Standard Accessories 8 channel input cable U Temperature measuring adapter CT-2A 8 A/D Converter Card AD-40AS/AD-40AS-F 8-channel voltage input card. *Type with antialiasing filters is the AD-40AS-F. Channels 8 Measuring Range ±5 V, ±10 V, OFF Within ±0.1%FS Input Frequency DC to 50 khz Antialiasing LPF (AD-40AS-F only) Transfer characteristic: 8th order Butterworth to Sensor Within ±2.5 V ±1% each channel AD-40AS 32

34 Sensor Interface PCD-400A/430A Combined G-resistant Data Logger MCA-200A Measurement using 1 unit with 4 channels, up to 4 units with 16 channels possible Dynamic Data Acquisition Software DCS-100A is included as a standard accessory. PCD-400A for measuring strain, PCD-430A for measuring strain and voltage Variety of input adapters Measures static and dynamic phenomena alternately. PCD-400A PCD-430A Common Specifications of PCD-400A/430A Measuring Target Strain (gages, transducers) Channels 4 Within ±0.1%FS Range Max μm/m, 7 steps Accuracy: Within ±0.5% FS Frequency Response DC to 200 Hz, deviation: Within ±10% Sampling Frequency Max. 10 khz A/D Converter 24 bits Interface USB2.0 (Conforms to High-speed USB standards. USB3.0 supports.) Operating Temperature and Humidity Range 0 to 40 C 20 to 85%RH (Noncondensing) mm (Excluding protrusions) Approx. 700 g (PCD-400A)/Approx. 750 g (PCD-430A) Channels 32 Measuring Target Strain (gages, transducers), voltage, thermocouples, pulse, piezoelectric acceleration (built-in amplifier), CAN signals Sampling Frequency Max. 100 khz Storage CF cards Impact Resistant 196.1m/s 2 (20 G)/11 ms 10 to 18 VDC mm (Excluding protrusions) Approx.10 kg (Approx.10.5 kg with 4 CDV-40B cards mounted) Measuring Voltage Specifications of PCD-430A Range Frequency Response Max. 50 V, 6 steps Accuracy: Within ±0.2% FS DC to 1 khz Printed Circuit Assembly Stress Measurement Set PCAS-1000A Software and data recording device specializing in measurements using IPC/JEDEC-9704A standards. PCAS-100A PCD-400A UI-55A Housing Case PCAS series Model Data Acquisition Data Analysis Creating Report Available Channels With PCD-400A PCAS-100A PCAS-200A PCAS-1000A Yes Yes Yes Yes Yes Yes Yes Yes Yes *Evaluation method for PCA using strain gages is regulated by IPC/ JDEC-9704A and it is valid for quality evaluation or failure analysis. 33

35 Instrumentation Amplifiers Applications Load Cell Controlling winding motor speed and tension Relay output CC-Link BCD data output Analog output Compression Load Cell Mount Base Junction Box SJB-4C Analog output Instrumentation Amplifier WGA-650B Junction Box SJB-4C Instrumentation Amplifier WGA-680A Monitoring control of tanks Controlling of cloth tension OK/NG Indicator Hydraulic cylinder Judge start signal Load Cell Beam-type Load Cell (Built in the case) Belt conveyor OK/NG Indicator Press-fitting material Instrumentation Amplifier WGA-900A High-speed, Compact Indicator WGI-470AS1 Press-fitted material Measurement of press-fit load Measurement of flour weight Instrumentation Amplifier WGA-900A Instrumentation Amplifier WGA-680A Touch-sensitive LCD Display waveforms. Comparators: 5 points of extra high (HH), high (HI), OK, low (LO) and extra low (LL). Options: BCD-output, D/A output, and RS-485 Sampling speed: 4000 times/s, resolution: 24 bits Comparators: 5 points of extra high (HH), high (HI), OK, low (LO) and extra low (LL). (Able to register 4 patterns.) Various options: CC-Link, BCD output, RS-232C, and RS-485 Numeric data and comparators' LED lights up (Red, green, orange). Channels 1 Applicable Transducer Strain-gage transducers Measuring Range ±3.2 mv/v (Including zero adjustment range) Bridge Excitation 10, 2 VDC switchable Sampling Speed 4000 times/s A/D Converter 24 bits Within ± (0.02% FS + 1 digit) Analog Monitor Voltage output: ±(5 V ±200 mv) Display to Refresh speed: 3 times/s 100 to 240 VAC mm (Excluding protrusions) Approx. 1.0 kg (Excluding options) Channels 1 Applicable Transducer Strain-gage transducers Measuring Range ±3.2 mv/v (Including zero adjustment range) Bridge Excitation 10, 2 VDC switchable Sampling Speed 4000 times/s A/D Converter 24 bits Within ± (0.02% FS + 1 digit) Display to (Decimal point is able to be set anywhere) 100 to 240 VAC 10 to 30 VDC (Select one) mm (Excluding protrusions) Approx. 750 g (Excluding options) 34

36 Instrumentation Amplifier WGA-650B Wide no-load zero adjustment range (±2 mv/v) High/low limit comparators (2 points: High/Low) D/A output built-in as standard (BCD data output model currently in preparation.) Outputs the indicated value in a voltage range of 0 to 10 V or in a current range of 4 to 20 ma. Instrumentation Amplifier WGI-470AS1 2-analog output: Simultaneous output of voltage and current, separate scaling. Channels 1 Applicable Transducer Strain-gage transducers Measuring Range 0 to 2.5 mv/v Bridge Excitation 10, 2 VDC switchable Sampling Speed 4 times/s Within ±(0.03% FS + 1 digit) Display to to 127 VAC or 220 to 240 VAC 20 VA or less mm (Excluding protrusions) Approx. 1.3 kg Channels 1 Applicable Transducer Strain-gage transducers Measuring Range ±3.2 mv/v (Including zero adjustment range) Bridge Excitation 10, 2 VDC switchable Sampling Speed 2000 times/s ±(0.02% FS ± 1 digit) Display to to 240 VAC mm Approx. 400 g Instrumentation Amplifier WGA-710C Comparator function based on pre-set high/low limits and peak hold functions Carrier Type Instrumentation Amplifier WGA-120A Strong against inverter noise Voltage/current output switchable Channels 1 Applicable Transducer Strain-gage transducers Measuring Range ±3.2 mv/v Bridge Excitation 10, 5, 2.5 VDC switchable Sampling Speed 15 times/s Within ±(0.03%FS+1digit) Display to , 115, 200, 220 VAC (Select one) mm (Excluding protrusions) Approx. 1.7 kg Channels 1 Applicable Transducer Strain-gage transducers Measuring Range ±0.2 to ±5 mv/v Bridge Excitation 5 Vrms, 2 Vrms, 1 Vrms square wave (Switchable by changing internal jumper connection) Within ±0.1%FS Voltage ±10 V (Load resistance: 2 k Ω or more) Current 4 to 20 ma (Load resistance: 500 Ω or less, voltage output: 0 to 10 V) 10.5 to 15VDC, 100, 200, 240 VAC (Select one) mm (Excluding protrusions) DC power supply model: Approx. 350 g AC power supply model: Approx. 450 g Instrumentation Amplifier WGI-400A High/low limit patterns: 4 switchable Instrumentation Amplifier WGA-100B Outputs voltage and current simultaneously. Channels 1 Applicable Transducer Strain-gage transducers Measuring Range ±3.2 mv/v (Including zero adjustment range) Bridge Excitation 2, 4 VDC switchable Sampling Speed 50 times/s Within ±(0.1% FS ±1 digit) Display to to 240 VAC, 10 to 30 VDC (Select one) mm (Excluding protrusions) Approx. 300 g Channels 1 Applicable Transducer Strain-gage transducers Measuring Range ±0.25 to ±2 mv/v or more Bridge Excitation 10, 5 VDC (Switchable by changing internal jumper connection) ±0.02% FS ±10 V, 4 to 20 ma 100, 200 VAC, 10 to 30 VDC (Select one) mm (Excluding protrusions) Approx. 400 g 35

37 Instrumentation Amplifier WGA-101A Outputs voltage and current simultaneously. MONITOR terminals for monitoring voltages on the front panel Compact Digital Indicator WDS-180A/185AS1 Suitable for simple measurement of pressure, load, or displacement. Displays data in 4 digits. Channels 1 Applicable Transducer Strain-gage transducers Measuring Range ±0.25 to ±5 mv/v or more Bridge Excitation 10, 5, 2 VDC (Switchable by changing internal jumper connection) ±0.02% FS ±10V, 4 to 20 ma 100, 200 VAC 10 to 30 VDC (Select one) mm (Excluding protrusions) Approx. 650 g WDS-180A WDS-185AS1 4-channel Instrumentation Amplifier WGC-140A Up to 4 units of 350 Ω strain-gage transducers are able to be connected independently to respective amplifier circuits. Switchable indicated value, channel to channel or the total. Analog voltage output. High/low limit comparators for the total value (2 points: High/Low) Model WDS-180A (Constant voltage type) WDS-185AS1 (Constant current type) Channels 1 Measuring Range ±5 mv/v Display LCD: to 9999 AA size battery 2 Operating Time 24 h or longer continuously (Maganese batterries) mm (Excluding protrusions) Approx. 180 g (With AA size batteries) Channels 4 Applicable Transducer Strain-gage transducers Measuring Range ±3 mv/v (Including tare) ±0.05% FS Display to to 240 VAC 30 VA or less mm (Excluding protrusions) Approx. 1.2 kg Compact Digital Indicator WDS-190AS1/191AS1 Suitable for simple measurement of pressure, load, or displacement. Displays data in 5 digits, units, statuses, battery remaining capacity with back light. Instrumentation Controller WDC-810C1 WDS-190AS1 WDS-191AS1 For rolling mill and tension control Displays shared load, combined load and differential load of 2 measurement channels, and has 4 types of high-speed computation functions. Channels 2 Applicable Transducer Load cells Bridge Excitation 10 VDC ±2%, remote sensing possible Measuring Range ±2.5 mv/v converted value ±0.05%FS 100 VAC mm (Excluding protrusions) Approx. 3.3 kg Model WDS-190AS1 WDS-191AS1 (With record functions) Channels 1 Measuring Range ±5 mv/v Display LCD: to AA size battery 2 Operating Time 72h or longer continuously (Alkaline batteries) (When backlight off and 350-ohm transducers at 25 C, recorder off) mm (Excluding protrusions) Approx. 110 g (Without AA size battery) 36

38 Sensor Checker WDS-500BE Checks strain-gage transducers and strain amplifiers Outputs strains. Measures strain, I/O resistance, and insulation resistance. Channels 1 Measuring Target Strain-gage transducers, strain amplifiers Strain Measurement ±5 mv/v I/O Measurement 0 to 2000 Ω Insulation Measurement 0 to 300 MΩ AA size battery mm (Excluding protrusions) Approx. 220 g (With batteries) Handy Digital Indicator SDB-410CS Checks insulated resistance and measures strain. Connects the optional switch box to measure multi-channel data. Channels 1 Measuring Target Strain-gage transducers (60 to 1000 Ω) Strain gage Quarter, half or full bridge system Measuring Range ±19999 μm/m mm (Excluding protrusions) Approx. 450 g Strain Generator WDS-10 Power supply is not necessary. I/O Setting Accuracy 350 ±7 Ω Within ±(0.5% of reading +5 digits) (Dial value) mm Approx. 350 g 37

39 Please choose them depending on your system. Voltage Input Box VI-8A For measuring voltage of the CDV-40B and voltage and charge type acceleration sensor of the CVM-41A. Bridge Box DBV-120A-4/4T/4E/4ET DBV-350A-4/4T/4E/4ET DBV-120A-4 Channels 8 Connecting Target Voltage, piezoresistive acceleration sensors, charge type acceleration sensors (When using charge converters) Connector BNC mm (Excluding protrusions) Mainframe: Approx. 230 g With DBS-MOUNT: Approx. 290 g Channels 4 Connecting Target Strain gages Gage Method DBV-120A-4 Quarter-bridge 2-wire system (120 Ω) Quarter-bridge 3-wire system (120 Ω) Half-bridge system (120 Ω) Full-bridge system (120 Ω) DBV-350A-4 Quarter-bridge 2-wire system (350 Ω) Quarter-bridge 3-wire system (350 Ω) Half-bridge system (350 Ω) Full-bridge system (350 Ω) mm (Excluding protrusions) Mainframe: Approx. 280 g With DBV4-MOUNT: Approx. 350 g Applicable Wire Single wire: 0.4 mm to 1.2 mm (UL AWG 16 to 26) Twisted wire: 0.2 mm 2 to 0.75 mm 2 (UL AWG 20 to 24) T: With a mounting plate E: With a N-46 ET: With a mounting plate and N-46 Bridge Box for Quarter Bridge System DBS-120B-8/8T/8C/8CT DBS-350B-8/8T/8C/8CT Bridge Box DBV-120A-8/8C DBV-350A-8/8C DBS-120B-8 DBV-120A-8 Channels 8 Connecting Target Strain gages Gage Method Quarter-bridge 2-wire system, quarter-bridge 3-wire system Switchable mm (Excluding protrusions) Mainframe: Approx. 250 g With DBS-MOUNT : Approx. 300 g Applicable Wire Single wire: φ 0.4 mm to φ 1.2 mm (UL AWG 16 to 26) Twisted wire: 0.2 mm 2 to 0.75 mm 2 (UL AWG 20 to 24) Without C: With a N-104 T: With a mounting plate C: With a N-105 CT: With a mounting plate and N-105 Channels 8 Connecting Target Strain gages Gage Method DBV-120A-8(C) DBV-350A-8(C) Quarter-bridge 2-wire system (120 Ω) Quarter-bridge 2-wire system (350 Ω) Quarter-bridge 3-wire system (120 Ω) Quarter-bridge 3-wire system (350 Ω) Half-bridge system (120 Ω) Half-bridge system (350 Ω) Half-bridge opposite-leg system (120 Ω) Half-bridge opposite-leg system (350 Ω) Full-bridge system (120 Ω) Full-bridge system (350 Ω) mm (Excluding protrusions) Mainframe: Approx. 480 g Applicable Wire Single wire: φ 0.4 mm to φ 1.2 mm (UL AWG 16 to 26) Twisted wire: 0.2 mm 2 to 0.75 mm 2 (UL AWG 20 to 24) Without C: With a N-104 C: With a N

40 Software Dynamic Data Acquisition Software DCS-100A Setting of measurement conditions, data acquisition, data collection, data reproduction and file conversion are able to be completed just by using this software. Various graphs/numerical values (Y-time graphs, bar graphs, X-Y graphs, digital graphs, circular meters, and bar meters) Saves the measured data on PC's hard disk directly (With some restrictions on the sampling frequencies and the number of channels). Displays various graphs and numerical values on monitor windows. OS: Windows Vista, Windows 7, 8/8.1, 10 Data Analysis Software DAS-200A Data reproduction Y-time graphs, X-Y graphs, numerical values, file information, max. and min. Extracts the acquired files and converts them into the CSV files. Data analysis Statistical operation, arithmetic operation, FFT analysis, histogram analysis, filter processing, differentiation/integration, and lifetime prediction OS: Windows Vista, Windows 7, 8/8.1, 10 Applicable measuring instruments EDS-400A EDX-10 series EDX-100A EDX-200A EDX-5000A PCD-400A PCD-430A UCAM -550A NTB-500A Playing back video & reproducing data DCS-100A Optional Software DCS-101A/104A/105A/106A X-Y graphs Simultaneous Acquisition of Video and Numeric Data/ Arithmetic Operations/FFT Analysis Optional Software DCS-101A Records video simultaneously. Real-time arithmetic operations Monitors FFT analysis in real-time. GPS Data Acquisition Optional Software DCS-104A Monitors and acquires the positioning data, received from the GPS receiver, simultaneously with the measuring data. CANdb File Read Optional Software DCS-105A Loads the CANdb files and sets them in the CAN conditions for DCS-100A Applicable conditioner cards: CAN-41A Applicable cards for optional slot: ECAN-40A, EGPC-40A 1000-channel for UCAM -550A Optional Software DCS-106A Applicable measuring instrument: UCAM -550A Measures 1000 channels. FFT analysis 39

41 Printed Circuit Assembly Stress Measuring Software PCAS-100A Guidance function allows for beginners to set and perform strain measurements. Analyzes the stress measurement results of PCBs and creates reports. OS: Windows Vista, Windows 7, 8/8.1, 10 Creats reports according to the IPC/JEDEC-9704A. Printed Circuit Assembly Stress Analysis Software PCAS-200A Loads the acquired KS2 files by using Kyowa's measuring instruments and analyzes them according to the IPC/JEDEC-9704A. Creates reports. OS: Windows Vista, Windows 7, 8/8.1, 10 Locating gages Locating gages Creating reports Creating reports 40

42 Automotive Test Equipment Applications Torque Transducer Barrier load cell Bolt Axial Force Meter On-vehicle Data Logger for Crash Test DIS-7000 series Pressure Transducer Encapsulated Gage Automotive crash tests, sled tests, and pedestrian protection tests Memory Recorder/Analyzer EDX-5000A Universal Recorder EDX-200A Bench testing of engines and transmissions Evaluation of driving stability and quality Thin Pedal Force Transducer LPR-C Minimal error caused by off-set loads Easy attachment to a brake pedal Hand Brake Operating Force Transducer LB-B For measuring tension of hand brakes. Easy attachment and operation. 200 N to 2 kn Within ±0.3% RO Within ±0.3% RO Approx. 0.9, 1.8 mv/v Approx. 110 g (Excluding cable and accessories) 500 N, 1 kn 1 to 2 mv/v Safe Overload 120% Approx. 800 g Gear-change Lever Operating Force Transducer LSA-A-S1 Measures the 2-component force initiated by operating the gear-change lever. Accurate measurement with minimal mutual interference. Hand Brake Operating Force Transducer LBR-S-1KNSA2 Easy attachment and operation. Accurate measurement with minimal mutual interference. 200, 300 N Approx. 0.5 mv/v (For both Fx and Fy) Safe Overload 120% (For both Fx and Fy) Approx. 100 g *Interference: ±5% RO (Between Fx and Fy ) 1 kn Within ±1.0%RO Within ±1.0%RO Approx. 1.5 mv/v Safe Overload 120% Approx. 650 g 41

43 Slip-ring Type Wheel Torque Transducer Measures wheel driving/control torque while a vehicle is running. Usable for braking tests and traction control tests. Engine Pressure Transducer PE-30KF For measuring exhaust or inlet pressure Max. operating temperature: 300 C (Water-cooled) Slip-ring type Safe Overload Mounting Screw 3MPa Within ±1%RO 1 mv/v or more 130% (Static), 100% (Dynamic) M18 P=1.5 Approx.120 g (Excluding cable) 1 to 5 kn m Within±0.5% RO Within±0.5% RO Rotation Speed 2000 rpm/max Degree of Protection Drip-proofed by protective coating (IP44) Approx. 4 kg (For 2.5 kn m) Small-sized High-temperature Pressure Transducer PHF-S-S1 series Able to be installed in confined spaces. Tepmerature effect on zero: Within 0.008%RO/ C Compensated temperature: -40 to 150ºC Wheel 6-component Force Measuring System Measures 3 forces (Fx, Fy, Fz) acting on 3 orthogonal axes to the running axle at the wheel mounting part and 3 moments (Mx, My, Mz) around the axes. Using slip-ring to transmit signal 6-component processor integrates processors for all 4 wheels into a compact single unit package. With this device, a 4-wheel recording system can be implemented with ease. Dedicated signal processor EWF-100A Integrates processors for all 4 wheels into single unit. (Standard) Wheel Alignment Measuring System Measures relative displacement of wheels while a vehicle is running. Dedicated signal processor EWA-100A Integrates processors for all 4 wheels into single unit. Displacement Measurement Load: Fx ±20 kn, Fy ±12 kn, Fz ±20 kn Moment: Mx ±2.4 kn m, My ±4.0 kn m, Mz ±2.4 kn m Rotation speed: N ±2000 rpm X (Back and forward) ±200 mm Y (Right and left) ±150 mm Z (Up and down) ±200 mm Angle Measurement Steering angle ±60 Camber angle ±10 Accuracy Displacement 1 mm (X, Y, and Z) Angle Steering angle 0.1 Camber angle to 20 MPa Within ±0.3%RO Within ±0.2% RO Approx mv/v Mounting Screw R1/8, M8 1.25, M , M10 1.0, 5/16-24UNF, G1/8 Approx. 20 g (Excluding cable) Small-sized High-temperature Pressure Transducer PHF-S-SA2/4 Compensated temperature: -40 to 150 C (Excluding connector) 2 to 20 MPa Within ±0.3%RO (2MPSA2: Within ±0.4% RO) Within ±0.2% RO Approx. 2 mv/v (SA2), approx. 0.5 mv/v(sa4) Mounting Screw R1/8 (SA2), 5/16-24UNF (SA4) Approx. 50 g (SA2), approx. 20 g (SA4) Steering Force/Angle Transducer SFA-E-SA20 Easy attachment to the steering shaft Rotary encoder is used to detect steering angle, thereby ensuring high resolution. Dedicated indicator is separately available. *Steering angle : Detected by a built-in encoder *Output pulses: pulses per 360 Input: 2 channels for steering force and steering angle (pulse) Output: 3 channels for steering force (torque), steering angle, and steering angle speed (±5VDC for each) PHF-S-SA2 PHF-S-SA4 Steering force ±20 to 200 N m (To be specified when ordering) Steering force Within ±0.3% RO (±150 N m or more: Within ±0.5%RO) Steering force Within ±0.3% RO (±150 N m or more: Within ±0.5%RO) Steering force 2 V Safe Overload 120% Approx. 2.5 kg (Including 1 kg of steering wheel) Dedicated Indicator of SFA-E-SA20 The display unit can be separated from the conditioner unit The compact display unit can be fixed on top of the conditioner unit or installed on the windshield with the suction cups 42

44 Steering Force/Angle Transducer SFA-F-SA Easy attachment to a steering shaft. Steering force and steering angle are strain output. Steering force ±20 to 200 N m Steering angle ±3 rotations Steering force Within ±0.3% RO (±150 N m or more: Within ±0.5%RO) Steering angle Steering force Within ±0.3% RO (±150 N m or more: Within ±0.5%RO) Steering angle Steering force 1 mv/v or more Steering angle 1 mv/v or more Safe Overload 120% Approx. 3.3 kg (Including 1 kg of steering wheel) Steering Force/Angle Transducer SFA-H-SA Steering force outputs strain and steering angle outputs voltage. Steering force ±50, ±200 N m Steering angle ±5 rotations Within ±0.3% RO Within ±0.3% RO Steering force 1 mv/v or more Steering angle 5 V Safe Overload 120% Approx. 2.5 kg (Including 1 kg of steering wheel) Grip-design Steering Operation Force Transducer LSG-A Influence on inertia moment is small. Easy attachment and removing reduce preparation time for measurements. Does not obstruct airbag deflation. ±30, ±200 N Within ±1%RO Within ±1%RO 1.4 mv/v or more Approx. 160 g (±30 N), approx. 240 g (±200 N) Acceleration Transducer for Crash Test ASD-B Accessory dedicated connector enables its direct connection to the onboard crash test data recorder. Center of seismic mass is set at the tip of body for triaxial configuration of acceleration transducers. Undamped type ASD-B-2KH (Horizontal) Measuring Direction ASD-B-1KV/ASD-B-2KV (Vertical) ASD-B-1KH/ASD-B-2KH (Horizontal) ±9807, ±19613 m/s mv/v or more Safe Overload 200% Frequency Response DC to 4 khz Approx. 1 g (Excluding cable) ASD-B-2KV (Vertical) Acceleration Transducer for Crash Test ASDH-A Measures acceleration of car bodies and dummies. Transverse sensitivity is 1% much less than conversional models. Center of seismic mass is set at the tip of body for triaxial configuration of acceleration transducers. Undamped type Measuring Direction ASDH-A-1KV/ASDH-A-2KV (Vertical) ASDH-A-1KH/ASDH-A-2KH (Horizontal) ±9807, ±19613 m/s mv/v or more Safe Overload 200% Frequency Response DC to 4 khz Approx. 1.4 g (Excluding cable) Damped Acceleration Transducer for Crash Test ASE-A/ASER-A Damping type minimizes the resonance effect of impact acceleration. *Cables of the ASER-A is exchangeable when damaged. Damped Acceleration Transducer for Crash Test ASDE-A Damping type minimizes the resonance effect of impact acceleration. Damped Acceleration Transducer for Crash Test ASDR-A-1K Damping type minimizes the resonance effect of impact acceleration. Cable is exchangeable when damaged. ASDH-A-2KH (Horizontal) ASDH-A-2KV (Vertical) ASE-A ASER-A ±980.7 m/s 2 ±4903 m/s 2 ±9807 m/s mv/v or more 1 mv/v or more 2 mv/v or more Safe Overload 500% 400% 200% Frequency Response DC to 1 khz (Sensitivity deviation ±3%) 1 to 2 khz (Sensitivity deviation ±10%) 1 to 4 khz (Sensitivity deviation ±10%) Approx. 3 g (Excluding cable) ±9807 m/s 2 1 mv/v or more Safe Overload 200% Frequency Response DC to 1 khz (Sensitivity deviation ±3%) 1 to 4 khz (Sensitivity deviation ±10%) Approx. 1.2 g (Excluding cable) ±9807 m/s 2 2 mv/v or more Safe Overload 200% Frequency Response DC to 1 khz (Sensitivity deviation ±3%) 1 to 4 khz (Sensitivity deviation ±10%) Approx. 1.2 g (Excluding cable) 43

45 Semiconductor Acceleration Transducer for Crash Test ASM-200BA Undamped type ±1961 m/s 2 (Within ±0.5%RO optional) Approx. 1.3 mv/v Safe Overload 500% Frequency Response DC to 3.5 khz Approx. 1.2 g (Excluding cable) Semiconductor Acceleration Transducer for Crash Test ASM-1KBCV/BCH M3 Undamped type ±9807 m/s mv/v or more Frequency Response DC to 2.8 khz Approx. 4 g (Excluding cable) *ASM-1KBCV (Vertical), ASM-1KBCH (Horizontal) ASM-1KBCV Femur Load Cell LCF-2TA Measures impact-initiated load on the femur by mounting to the femur of a crash dummy such as Hybrid III. 20 kn Within ±0.4%RO Within ±0.4%RO 1 to 1.5 mv/v Safe Overload 120% Approx. 700 g (Excluding cable) Seat Belt Tension Transducer LBT-E Offers improved nonlinearity. Safe Overload 15, 20 kn Within ±1.5% RO (15KN), within ±2.0% RO (20KN) (With a built-in compensation circuit) Approx. 1.5 mv/v (15KN) Approx. 1.0 mv/v (20KN) 120% (15KN), 100% (20KN) Approx. 72 g Semiconductor Acceleration Transducer for Crash Test ASM-A-ID Undamped type ASM-A-2KV-ID (Vertical) ±19613 m/s 2 6 mv/v or more Frequency Response DC to 2.8 khz Approx. 4 g (Excluding cable) Semiconductor Acceleration Transducer for Crash Test ASM-1KCBV Undamped type ASM-A-2KH-ID (Horizontal) Seat Belt Tension Transducer LBT-A-20KNSA1 Measures impact-initiated tension of a seat belt in crash tests. 20 kn Within ±2% RO Approx. 2.5 mv/v Safe Overload 100% Approx. 130 g Seat Belt Tension Transducer for CRS LBT-D-100NSA1-H Measures tension of the belt fixing the child seats. ±9807 m/s 2 (Within ±0.5%RO optional) 1.5 mv/v or more Safe Overload 120% Frequency Response DC to 3.5 khz Approx. 4.3 g (Excluding cable) 100 N Within ±1.5% RO (With a built-in compensation circuit) 1.0 mv/v or more Safe Overload 120% Approx. 65 g Neck 6-component Force Transducer LSM-E-15KNS1 Measures 6-force component acting on the neck by mounting to the neck of a crash dummy such as Hybrid III. Seat Belt Tension Transducer for CRS LBT-B-200NSA1-P Offers improved nonlinearity. Fx, Fy ±10 kn Fz ±15 kn Mx, My, Mz ±300 N m Within ±1%RO Within ±1%RO Fx, Fy, Mz Approx. 1.7 mv/v Fz Approx. 0.6 mv/v Mx, My Approx. 1.2 mv/v Safe Overload 120% Approx. 0.7 kg 200 N Within ±3% RO Approx mv/v Approx. 90 g 44

46 Sensor Checker DTWU-55A Checks voltage, strain (initial data, I/O resistance, and insulation resistance) in a series Displays waveforms in real time. On-vehicle Data Logger for Crash Test DIS-5010A On-vehicle unit designed to acquire 32-channel of crash test data with excellent impact resistant Built-in batteries resulting in no required external power supply during measurement Large capacity flash memory (Enables to record 75 s at sampling of 10 khz) The tablet or PC is an optional item. Measuring Target Strain-gage transducers (full bridge), voltage Channels 1 Input Range Bridge Excitation Built-in Battery Initial Measurement Accuracy I/O Measurement Measuring Range Strain: ±10000 μm/m Voltage: ±6 V 2, 5, 10 VDC Type: Li-ion Recharge time: Approx. 6h Operating time: Approx. 5h Strain-gage transducers: ±(0.2% of reading+5 μm/m) Voltage: ±(0.2% of reading+5 mv) 0 to 2000 Ω Accuracy ±(0.2% of reading+5 Ω) Insulation Measurement Measuring Range Applied Voltage Accuracy 0 to 300 MΩ Approx. 15 VDC ±(1.5% of reading+1 MΩ) Data Acquisition System for Crash Test DIS-7000 series Impact resistant: 980.7m/s 2 (100G) Modularization structure enables to optimize your system Synchronous measuring channels up to 1056 (Up to 999 channels when using DIS-70A) Outputs ignition current based on the pre-set delay time. (DIA-708A) Records the CAN data. (DIC-706A) Measuring Target Strain (gages, transducers), piezoresistive transducers, voltage, potentiometer transducers, voltage-output transducers, and digital signals Channels 32 (analog) Max. 6 units (analog 192 channels) Input Voltage ±20 V LPF Fixed filters, variable filters Sampling Frequency Max. 100 khz Trigger External triggers, level triggers, cascade triggers, and software triggers Impact Resistant m/s 2 (100 G) On-vehicle Airbag Timer for Crash Test DIA-512A The ignition current level and output delay can be set channel by channel. Digital signals are output in synchronization with current output each channel. Channels 12 Output Current 0.5 to 3.0 A and OFF (Step: 0.1 A) Output Time Setting range: 1 to 5 ms (Step: 1 ms) Delay Time Setting range: 0.1 to ms (Step: 0.1 ms) Digital Output Channels 16 Impact Resistant m/s 2 (100 G) On-vehicle High Voltage Data Logger for Crash Test DIV-503A Signal Conditioner Module DIS-724A-T/L Measuring Target Strain, voltage Channels 24 (analog) Synchronous measuring channels up to 1056 (Up to 999 channels when using DIS-70A) Input Voltage Within ±20 V LPF Transfer characteristic: 5th order Butterworth Sampling Frequency Max. 100 khz Trigger Switch trigger, analog trigger, cascade trigger, software trigger Impact Resistant m/s 2 (100 G) Airbag Timer Module DIA-708A Channels 8 Output Current 0.5 to 3.0 A (Step: 0.1 A) Output Time Setting range: 0.2 to 5 ms (Step: 0.1 ms) Delay Time Setting range: 0.1 to 9999 ms (Step: 0.1 to 1 ms) Impact Resistant m/s 2 (100 G) CAN Measurement Module DIC-706A Channels 6 Physical Layer High speed CAN Insulation Every channel Termination Resistor ON/OFF switchable Memory Capacity Approx. 200M frames (Total 6 channels) At sampling frequency 20 khz, measurement for approx. 62 s and at 100 Hz, for approx. 8 h. Real-time measurement (Sampling frequency 100 Hz or less) Frequency response: DC to 1 khz High-speed data transmission by using the 100BASE-TX Measuring Target Voltage Channels 3 Measuring Range ±500, ±250 VDC Impact Resistant 980.7m/s 2 (100 G) Withstand Voltage Sampling Frequency Small-sized Data Logger for Crash Test DIS-503A For pedestrian protection test Channels 3 Impact Resistant 4903 m/s 2 (500 G) Sampling Frequency 1000 Vrms Max. 20 khz Max. 150 khz 45

47 Small-sized Data Logger for Crash Test DIS-506A Analysis Software for Barrier Force Transducer Analyzes the data obtained by colliding a test vehicle against the force sensor matrix. For pedestrian protection test Channels 6 Impact Resistant 4903 m/s 2 (500 G) Sampling Frequency Max. 150 khz Small-sized Data Logger for Crash Test DIS-618A, DIS-632A Small-sized data loggers to be built in the dummies for acquiring data. Channels DIS-618A: 18, DIS-632A: 32 Impact Resistant 4903 m/s 2 (500 G) Sampling Frequency Max. 100 khz Data Logger for Crash Test DIS-5210A Large-capacity flash memory (75 seconds at 10 khz) Measures signals of foil/semiconductor strain gages, strain-gage transducers and voltage-output sensors as well as digital signals. Measuring Target Channels Input Voltage Range LPF Sampling Frequency Trigger Strain (gages, transducers), piezoresistive transducers, voltage, potentiometer transducers, voltage-output transducers, and digital signals 8 (analog) ±20 V Fixed filters, variable filters Max. 100 khz External triggers, level triggers, cascade triggers, and software triggers Multi-division Force Transducer for Barrier Measures distributed loads on crash surface. Consists of 128 load cells (8 columns 16 rows) 500 kn 48 cells, 300 kn 80 cells Within ±1%RO (In static calibration) Within ±1%RO (In static calibration) Approx mv/v (Each cell) Recommended Excitation 1 to 5 V AC or DC Safe Overload 120% 46

48 Traffic System "Handy Scale" Portable Weighing Systems HS series Unique aluminum integrated structure for minimal eccentric error Car No. can be input and printed with the built-in printer. Portable Vehicle Weighing System RWP-700A/750A Improved operability ensures easier truck weighing in the field. USB memory for transferring data to PC Cable disconnection check function (RWP-700A only) Built-in printer (Able to print the measured results in the filed.) Detector Detector Indicator Basic System Composition Indicator: 1 unit Detector: 2 units Detector s Weighing 500 to 7500 kg per unit (Axle loads: 1000 to kg) Number of applicable axle Up to 7 Radio Communication Frequency 920 MHz (Specified low-power radio) (RWP-750A) Radio Communication Length Within approx. 10 m (No obstacles, shielding or radio wave interferences.) (RWP-750A) Indicator Specifications of detectors 1000 to 5000 kg (Per detector) Within ±0.1%RO Within ±0.1%RO Approx. 0.7 to 1.0 mv/v Safe Overload 120% Specifications of indicator Channels 4 to 8 Display Content Axle, axle load, left, right, total weight, ratio%, and cross% Accuracy Within ±0.03% FS Printer 5 x 7, dot impact printer 100 to 240 VAC or 12 VDC Approx. 7 kg Specifications of detectors Rated Load (per unit) Safe Load (per unit) 7500 kg kg Operating Temperature -10 to 60 C Detector: 835 x 35 x 480 mm Loading section: 700 x 26 x 350 mm Approx. 24 kg Specifications of indicator Printout Content Indication Unit Measurement Mode Operating Temperature and Operating Humidity Storage s Measuring year, month, date, total truck load, each axle load, truck identification number 10 kg Stop mode (Recommended), running mode (5 km/h max.) -10 to 40 C 20 to 80% RH (Non-condensing) Buillt-in battery (For 8 h operation) 10 to 30 VDC, 100 to 240 VAC if AC adapter is used Internal memory stores data up to 1000 trucks. (Data is transferred to PC via USB memory.) 348 x 149 x 295 mm (Excluding protrusions) Approx. 3.7 kg Test Systems Gait analysis system Wind pressure measuring system Shaking table measuring software Pipe stress measuring system Handy type load control unit 47

49 Civil Engineering/ Construction Instruments Applications NETIS: No. KT A Aki-Mos tension monitoring system of existing anchors Data Logger UCAM -60B Inclination Transducer Hollowed load cells Transmitters Water-level Meter Dynamic observation of earth filling Receiver Strain Transducer (Kyowa products used in the Aki-Mos.) Load cell (1000 kn) NTB-100 series NTB-100A BLWL-B Monitoring system Measure both strain inside lining concrete and timbering strain. Embedment Type Inclination Transducer BKJ-A Able to be installed up to 20 stages in one guide pipe. Insertion Type Inclination Transducer BK-G Highly reliable performance ensures safe use in fields. Cable and reel are standard accessories: The cable enables measurement up to 50 m deep. ±5, ± mv/v or more (Minus rated capacity to plus rated capacity) Measuring Direction 1, 2 directions ±5, ± mv/v ±0.5% (Minus rated capacity to plus rated capacity) Guide Roller-equipped Inclination Transducer BKL-A Able to be installed up to 15 stages in one guide pipe. No grouting work required in the guide pipe Surface-mounting Type Inclination Transducer BKK-A Able to be wall-mounted for measuring minor inclination of structure. High resolution ±5, ± mv/v or more (Minus rated capacity to plus rated capacity) ±1, ±2 2 mv/v or more (±1 ) 3 mv/v or more (±2 ) Measuring Direction 1, 2 directions 48

50 Hollowed Load Cell BL-B/E Measures loads applied to an earth anchors or the support of tunnel arches. Strain Transducer BS-25AT/25BT Measures strain inside concrete. BL-20TB BS-25AT BL-B: 5 to 500 kn BL-E: 1 to 2 MN Within ±0.5 to 2% RO 1 mv/v or more BS-AT: ±500 μm/m BS-BT: ±1000 μm/m BS-AT: Within ±1.5% RO BS-BT: Within ±2% RO Within ±2% RO 2.5 mv/v or more (Minus rated capacity to plus rated capacity) *Temperature measuring range: -30 to 70 C Hollowed Load Cell BLWL-B Aki-Mos compatible center hole diameter and outside diameter. Small-sized Strain Transducer BS-8FT Suitable for strain measurement on earth retaining strut, steel sheet pile and tunnel support. 500 kn, 1 MN Approx. 1 mv/v ±1000 μm/m Within ±2% RO Within ±3% RO 2.6 mv/v or more (Minus rated capacity to plus rated capacity) *Temperature measuring range: -30 to 70 C Hollowed Load Cell BLW-A Eccentric load or inner/outer load causes less sensitive deviation. Degree of protection: IP68 Surface-mounting Type Strain Transducer BS-15CT Measures strain on steel and concrete surfaces. 500 kn to 2 MN Within ±0.8% RO 1.25 mv/v or more ±2000 μm/m Within ±2% RO Within ±2% RO 1.25 to 2.5 mv/v (Minus rated capacity to plus rated capacity) *Temperature measuring range: -30 to 70 C Hollowed Load Cell BLD-A-S Measures the load applied to the PC anchors and lock bolts Low-elasticity Strain Transducer BSL-A-90TSA2 Measures strain from young material age since the thermally-induced apparent strain is small (approx. 20 MPa). With temperature measurement function, removable flange 50 to 500 kn 1 mv/v or more ±6000 μm/m Within ±1%RO Within ±1%RO 4 mv/v or more (Minus rated capacity to plus rated capacity) *Temperature measuring range: -30 to 70 C 49

51 Reinforcing-bar Stress Transducer BF-CT Measures stress of reinforcing bars. Small-sized Pore Pressure Transducer BPR-A-S Outer diameter: φ20 mm 300 MPa Within ±1.5% RO 1.85 mv/v or more *Temperature measuring range: -30 to 70 C *Applicable reinforcing bar: SD345 *Deformed reinforcing bar: D10 to D32 Reinforcing-bar Stress Transducer BFD-A-TS Measures stress of reinforcing bars. *Temperature measuring range: -30 to 70 *Applicable reinforcing bar: SD345 *Deformed reinforcing bar: D35 to D51 Pore Pressure Transducer BPB-A/BPB-A-T Outer diameter: φ30 mm A flat filter attached Stainless steel case 300 MPa 1.85 mv/v or more *Temperature measuring range: -30 to 70 C (BPB-A-T) *Mounting screw: R3/4 200, 500 kpa 2 mv/v ±2% *Mounting screw: M30, P=2 200 kpa to 2 MPa (200KP: Within ± 2% RO) 1 mv/v or more (200KP: 0.75 mv/v or more) Pore Pressure Transducer BPC-A Double-cased structure ensures measurement without receiving any effect of lateral pressure. A flat filter attached Stainless steel case 200 kpa to 2 MPa (200KP: Within ± 2% RO) 1 mv/v or more (200KP: 0.75 mv/v or more) *Mounting screw: R3/4 High-sensitivity Pore Pressure Transducer BPG-A-S High sensitivity (4000 μm/m) Excellent temperature characteristics (±0.02% RO per C) A cone filter attached 50 to 200 kpa (50KPS: Within±2% RO) 0.4 to 1.0 mv/v or more *Mounting screw: M10, P=1 Small-sized Pore Pressure Transducer BPA-F-S Outer diameter: φ10 mm Able to be embedded for use in short-term testing operations. Soil Moisture Transducer BPT-A-80KPS Grasps the safety of the water in landslide blocks and embankments. 200, 500 kpa 0.85 mv/v ±30% (200KPS), 1 mv/v ±20% (500KPS) -80 kpa (200 kpa for positive pressure) Approx mv/v Water Level Transducer BWL-ET Measures fluctuation of underground water level. Lightning arrester element built in. Atmospheric pressure compensated Water level 10, 20, and 30 m Within ±0.15% RO Within ±0.10% RO 2 mv/v or more *Temperature measuring range: -20 to 60 C *Stainless steel structure, φ32 mm 133 mm Temperature Transducer BT-100B For embedded application (Hydraulic pressure resistant: 200 kpa) Resolution: 0.01 C Output: 50μV/V per C -30 to 70 C Measurement Error ±0.3 C Approx. 120 g Small-sized Temperature Transducer BTS-100AT Embedded application possible for model experiments and short-term measurement Usable only in combination with a measuring instrument compatible with resistance thermometers. -30 to 70 C Measurement Error ±0.5 C Approx.10 g 50

52 Joint Transducer BJ-AT Measures an opening degree of joint, such as between concrete blocks Measures crack of rock-bed. 5 to 50 mm Within ±1.5% RO Within ±1.5% RO 1 mv/v or more *Temperature measuring range: -30 to 70 C Displacement Transducer BJB-C-S/D-S/E-S C-S series is suitable for measuring rock-bed displacement, D-S series is suitable for measuring soft ground settlement, and E-S series is suitable for measuring rock-bed displacement in NATM. Rock-bed Compression Displacement Transducer BRD-AT Detects relative displacement between the anchor and ground surface. 5 to 50 mm Within ±1.5% RO Within ±1.5% RO 1 mv/v or more *Temperature measuring range: -30 to 70 C Stress Transducer BR-BT Measures concrete stresses. 50 to 2000 mm Within ±2% RO Approx. 1 mv/v BJB-C-S 2 to 10 MPa 1 mv/v or more *Temperature measuring range: -30 to 70 C Concrete Surface Displacement Transducer BCD-E-70S Easy attachment by the dedicated fixture and adhesive. Screw fixing makes it reusable. * Tension: 2.0% strain or less (0 to 1.40 mm) Compression: 0.5% strain or less (0 to 0.35 mm) Within ±3% RO Within ±3% RO Approx. 2.5 mv/v *With a gage mark distance of 70 mm Soil Pressure Transducer BEE-A/BEF-A Highly accurate. Displacement ratio of the pressure-sensing surface to its diameter is less than 1/ BEE-A (For underground soil pressure) BEF-A (For wall-surface soil pressure) Crack Displacement Transducer BCD-5B Measures cracks occuring on rock-bed and concrete. Small measuring force enables installation to weak rock-bed. 200 kpa to 2 MPa (200KP: Within±3% RO) Within ±1%RO 1 mv/v or more 200KP: 0.9 mv/v or more Recommended Excitation 2 to 10 V AC or DC Safe Overload 120% Pressure-sensing Surface Approx. 160 Approx. 6 kg (BEE), approx. 5.7 kg (BEF) ±5 mm Within ±2% RO Within ±2% RO 1 mv/v ±5% *Measuring force: Approx. 9.8 N/5mm Drip Proof Large-capacity Displacement Transducer DTP-E-S Potentiometer-type displacement transducer Large-output, small measuring force 500 to 2000 mm Approx. 5 mv/v Soil Pressure Transducer BEM-A Stainless steel case 50 kpa to 1 MPa Within ±2% RO (500KP and 1MP: Within±1% RO) Within ±1%RO 50KP: 0.25 mv/v or more 100KP: 0.5 mv/v or more 200KP or more: 1 mv/v or more Recommended Excitation 2 to 8 V AC or DC Safe Overload 120% Pressure-sensing Surface Approx. 80 Approx. 1 kg 51

53 Soil Pressure Transducer BEN-A Vibration-resistant design for installation on driven materials Highly wear-resistant pressure sensing surface 500 kpa, 1 MPa Within ±1%RO Within ±1%RO 1 mv/v or more Recommended Excitation 2 to 8 V AC or DC Pressure-sensing Surface Wall-surface Soil Pressure Transducer BER-A-110S Stainless steel case Able to use as wave pressure gages by marine growth preventing coating (custom-made). 100 kpa to 2 MPa Within±1% RO Within±1% RO 1 mv/v or more Recommended Excitation 1 to 5V AC or DC Safe Overload 120% Pressure-sensing Surface Approx. 70 Approx. 1 kg Small-sized Soil Pressure Transducer BEC-A/BED-A For short-term experiments 200 kpa to 1 MPa Within ±2% RO 0.25 mv/v or more Recommended Excitation 2 to 4 V AC or DC Safe Overload 120% Pressure-sensing Surface Approx. 23 Approx. 120 g Approx. φ95 Approx. 2.2 kg Wall-surface Soil Pressure Transducer BER-A-12S/58S Suitable for the chamber soil pressure of shield machine. BER-A-12S BER-A-58S 100 kpa to 5 MPa Within±1% RO Within±1% RO 1 mv/v or more Recommended Excitation 2 to 5 V AC or DC Safe Overload 120% Pressure-sensing Surface Approx. φ73 Approx. 3.2 kg (12S), approx. 3.1 kg (58S) BEC-A BED-A Wall-surface Soil Pressure Transducer BER-A-15S/17S Suitable for wall-surface soil pressure measurement of a small shield machine. BER-A-15S 500 kpa to 5 MPa Within±2% RO Within±2% RO 1 mv/v or more Recommended Excitation 2 to 5 V AC or DC Safe Overload 120% Pressure-sensing Surface Approx. φ24.5 Approx. 400 g (15S), approx. 500 g (17S) Wall-surface Soil Pressure Transducer BER-S-12SA2 High overload protection (Safe overload up to 1000%) 1000% overload against the decenter load (With a stopper) Recommended Excitation Safe Overload Pressure-sensing Surface BER-A-17S 100 kpa to 3 MPa Within±1% RO Within±1% RO Approx. 1 mv/v 1 to 10 V AC or DC 1000% full pressure (Full pressure = Variable pressure + pore pressure) Approx. φ to 4.4 kg (Excluding cable) Wall-surface Soil Pressure Transducer BER-S-15SA1/17SA1 High overload protection (Safe overload up to 1000%) 1000% overload against the decenter load (With a stopper) Recommended Excitation Safe Overload Pressure-sensing Surface BER-S-15SA1 BER-S-17SA1 500 kpa to 3 MPa Within±2% RO Within±2% RO Approx. 1.5 mv/v 1 to 10V AC or DC 1000% full pressure (Full pressure = Variable pressure + pore pressure) Approx. φ24 BER-S-15SA1: 150 g (Excluding cable) BER-S-17SA1: 800 g (Excluding cable) Wall-surface Soil Pressure Transducer BER-S-35SA1 High overload protection (Safe overload up to 1000%) 1000% overload against the decenter load (With a stopper) 500 kpa to 3 MPa Within±2% RO Within±2% RO Approx. 1.5 mv/v Recommended Excitation 1 to 10V AC or DC Safe Overload 1000% full pressure (Full pressure = Variable pressure + pore pressure) Pressure-sensing Surface Approx. φ 24 Approx. 400 g (Excluding cable) 52

54 Wall-surface Soil Pressure Transducer BER-S-79SA1 High overload protection (Safe overload up to 1000%) 1000% overload against the decenter load (With a stopper) Recommended Excitation Safe Overload Pressure-sensing Surface Digital Strain Recorder RMH-301B Suitable for long-term measurement in the absence of personnel under the environment without external power supply Equipped with a display used to confirm setting conditions and measured values. Easy to collect data by USB memory 500 kpa to 3 MPa Within±2% RO Within±2% RO Approx. 1.5 mv/v 1 to 10V AC or DC 1000% full pressure (Full pressure = Variable pressure + pore pressure) Approx. φ24 Approx. 230 g (Excluding cable) Digital Strain Recorder RMH-310A Suitable for long-term measurement in the absence of personnel under the environment without external power supply Equipped with a display used to confirm setting conditions and measured values. Easy to collect data by USB memory. No control software required. Keys are provided for operation as an independent unit. Measurement with thermocouples possible (K, T) Measures 10 channels. Channels 10 Applicable Transducer Strain-gage transducers Strain gage civil engineering transducers Civil engineering transducer with a thermal sensor Thermocouples (K, T) Applicable Bridge 350 Ω (Full-bridge system) Measuring Range Strain ±20000 μm/m Temperature (Civil engineering transducer) to 70.0 C Temperature (Thermocouple) K: -200 to 1200 C T: -200 to 350 C Resolution Strain 1 μm/m Temperature (Civil engineering transducer) 0.1 C Temperature (Thermocouple) 0.1 C Storage data/channel Interval Measurement 1 to 59 minutes (1 minute step) or 1 to 99 hours (1 hour step) 6 to 15 VDC (An optional battery pack is available.) Number of Measurement Times 7000 times or more (When measuring at interval of 10 minutes at 23 C using the optional RB-10A battery pack [10Ah].) mm (Excluding protrusions) 2 kg or less (Excluding the battery) Channels 1 Applicable Transducer Strain-gage transducers Strain gage civil engineering transducers Civil engineering transducer with a thermal sensor Applicable Bridge 350 Ω (Full-bridge system) Measuring Range Strain ±20000 μm/m Temperature (Civil engineering transducer) to 70.0 C Resolution Strain 1 μm/m Temperature (Civil engineering transducer) 0.1 C Storage Strain times Temperature (Civil engineering transducer) times Strain + temperature times Interval Measurement 1 to 59 minutes (1 minute step) or 1 to 99 hours (1 hour step) 6 to 15 VDC (An optional battery pack is available.) mm (Excluding protrusions) Approx. 180 g Cable Connection Materials Kyowa Cable Connection Kits JB-200A, JB-210A Applicable outer diameter of cable sheath: φ6 to 16 mm Kyowa Lightning Arrester Kit JB-100C Applicable outer diameter of cable sheath: φ6 to 16 mm Compact Lightning Protection Connection Kit JB-300A Applicable outer diameter of cable sheath: φ6 to 16 mm Cable Connectors with Waterproof Cap B-10B, B-15B Protects the extension cable tip of the civil engineering transducer. Control software RMH-390A (Optional accessories) OS Windows Vista JB-100C 53

55

56 You can count on Kyowa. Feel free to contact us, if there is something you would like to know or do not understand about Kyowa products. Sales Network Americas Region KYOWA AMERICAS, Inc. TEL: Web: China Thailand Japan Americas Region China KYOWA ELECTRONIC(SHANGHAI)TRADING CO.,LTD. TEL: + support-cn@d1.kyowa-ei.co.jp Web: Thailand KYOWA DENGYO(THAILAND) CO.,LTD. TEL: + sales-thailand@kyowa-ei.co.th Web: Other Countries or Regions Please visit below URL. Web: Cat.No. 507h E11-2 Printed in Japan June 2017

General-purpose Foil Strain Gages KFG

General-purpose Foil Strain Gages KFG General-purpose Foil Strain Gages KFG -8 General-purpose Foil Strain Gages in KFG Series Grid width Grid length (Gage length) Base length The KFG series gages use polyimide resin for the base approx. μm

More information

General-purpose Foil Strain Gages (KFGS)

General-purpose Foil Strain Gages (KFGS) General-purpose Foil Strain Gages (KFGS) -8 General-purpose Foil Strain Gages KFGS Grid width Grid length (Gage length) length The KFGS series gages use polyimide resin for the base that is approx. μm

More information

General-purpose Foil Strain Gages KFGS Series

General-purpose Foil Strain Gages KFGS Series General-purpose Foil Strain Gages KFGS Series KFGS New strain gages with the world highest level performance Point CE compliant All models are RoHS compliant Point Improved Quality Excellent long-term

More information

Acceleration Transducers

Acceleration Transducers Acceleration Transducers Using a foil, sputter or semiconductor strain gage as the sensing element, KYOWA acceleration transducers convert the acceleration of a running vehicle or the vibration of a car

More information

Automotive Test Equipment5

Automotive Test Equipment5 Automotive Test Equipment5 Automotive Test Equipment Automotive Test Sensors Crash Test Sensors Crash Test Measuring Systems Note: When using for special purposes, contact us. For prices and delivery date,

More information

vibrati vibration solutions by sensor type Measurement Specialties brings more than twenty years of

vibrati vibration solutions by sensor type Measurement Specialties brings more than twenty years of vibration solutions by sensor type Measurement Specialties brings more than twenty years of vibrati experience in the design and manufacture of s and gyros based on our proprietary Micro-ElectroMechanical

More information

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD. KYOWA ELECTRONIC INSTRUMENTS CO., LTD. COMPACT RECORDER EDS-400A Compact Dynamic Strain Recorder Entering the scene in advanced measurement of strain, vibration, pressure, load, etc. New www.kyowa-ei.co.jp

More information

Sensors for Vibration, Acceleration, and Shock Measurement. Product Catalog

Sensors for Vibration, Acceleration, and Shock Measurement. Product Catalog Sensors for Vibration, Acceleration, and Shock Measurement Product Catalog Company Overview VISONG TEST is a Sino-US joint venture specialized in the field of vibration transducer and dynamic measurement

More information

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications.

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications. Code No: R05310305 Set No. 1 III B.Tech I Semester Regular Examinations, November 2008 DESIGN OF MACHINE MEMBERS-I ( Common to Mechanical Engineering and Production Engineering) Time: 3 hours Max Marks:

More information

Sensors for Small Forces

Sensors for Small Forces Force Sensors for Small Forces 0,5... 0,5 N to 500... 500 N Type 9203, 9205, 9207, 9215A, 9217A These slim sensors are designed for dynamic and quasistatic tensile and compression forces. Depending on

More information

MEMORY RECORDER/ANALYZER

MEMORY RECORDER/ANALYZER NEW MEMORY RECORDER/ANALYZER By the Specialist in Stress Measurement All-in-one All-purpose Instrument From Measurement to Monitoring, Recording and Processing The EDX-2000A is a general-purpose, expandable

More information

R30D RVDTs DC-Operated Rotary Variable Differential Transformers

R30D RVDTs DC-Operated Rotary Variable Differential Transformers R30D RVDTs DC-Operated Rotary Variable Differential Transformers RVDTs incorporate a proprietary noncontact design that dramatically improves long term reliability when compared to other traditional rotary

More information

General Specification

General Specification 2001 Catalog General Specification WISE SENSOR INC. WISE SENSOR INC. C O N T E N T S Product guide for pressure measurement Product guide for level measurement Product guide for temperature measurement

More information

Load Cells LOAD CELLS

Load Cells LOAD CELLS Load Cells Honeywell manufactures a wide range of tension, compression, and universal measurement load cells. Our load cells are industrially rugged and feature enhanced reliability due to stainless steel

More information

T40FH. Torque flange. Special features. Data sheet

T40FH. Torque flange. Special features. Data sheet T40FH Torque flange Special features - Nominal (rated) torques: 100kNm, 125kNm, 150kNm, 200kNm, 250kNm, 300kNm - Nominal (rated) rotational speed of 2000 rpm up to 3000 rpm - Compact design - Version for

More information

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0 Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.

More information

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R O P E R AT I O N M A N U A L Model 4800 L O A D C E L L S U M M I N G T R A N S M I T T E R CALEX Manufacturing Company, Inc. Concord, California 94520 Ph: 925/687-4411 800/542-3355 Fax: 925/687-3333 http://www.calex.com

More information

Force and weight measuring instruments

Force and weight measuring instruments JJ Force sensors and load cells JJ Hanging scales JJ Sensors for proof load testing JJ Water filled bags Force and weight measuring instruments DS_Force_and_weight_measuring_instruments 05/2016 97 Force

More information

K3D60a ±100N. Description. The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes.

K3D60a ±100N. Description. The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes. K3D60a ±100N Description The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes. The new 3-axis sensor K3D60a is a further development of the series K3D60 and

More information

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en T40FM Torque flange Special features Data Sheet - Nominal (rated) torque: 15 kn m, 20 kn m, 25 kn m, 30 kn m, 40 kn m, 50 kn m, 60 kn m, 70 kn m and 80 kn m - Nominal (rated) rotational speed up to 8000

More information

Dynamic Strain Amplifiers

Dynamic Strain Amplifiers Introduced in this catalog are KYOWA s flexible multi conditioner systems and dynamic strain amplifiers to measure signals sent from sensors such as strain gages and strain gage transducers. These sensors

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES Precision Low Profile Load Cell DESCRIPTION Model 41E is a low profile pancake type load cells. These bonded foil, strain gage load cells are engineered to measure loads from 20 N to 200 kn. The tension/

More information

Miniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C TP 301

Miniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C TP 301 Miniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C TP 301 Model 8540 miniature pressure transducer for absolute pressure measurement at 260 C Abstract A miniature,

More information

XPC10 High temperature miniature pressure sensor

XPC10 High temperature miniature pressure sensor Absolute, sealed and gauge ranges 10 to 500 bar [150 to 7 500 psi] High temp. operation from -40 up to 220 ºC [-40 to 428 F] Stainless steel construction Amplified output available For static and dynamic

More information

5. Transducers Definition and General Concept of Transducer Classification of Transducers

5. Transducers Definition and General Concept of Transducer Classification of Transducers 5.1. Definition and General Concept of Definition The transducer is a device which converts one form of energy into another form. Examples: Mechanical transducer and Electrical transducer Electrical A

More information

DIS-5010A, DIA-512A. Data Acquisition System for Crash Test AUTOMOTIVE TEST EQUIPMENT

DIS-5010A, DIA-512A. Data Acquisition System for Crash Test AUTOMOTIVE TEST EQUIPMENT , Data Acquisition System for Crash Test 5-40 On-vehicle Data Logger for Crash Test On-vehicle Airbag Timer for Crash Test On-vehicle Data Logger for Crash Test On-vehicle unit designed to acquire 32 channels

More information

Miniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C

Miniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C Miniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C PMiniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C Abstract A miniature,

More information

Model 3A Series 3-Axis Load Cell

Model 3A Series 3-Axis Load Cell Model 3A Series 3-Axis Load Cell 3-Axis Fx Fy Fz; Independent Bridges 20N to 500kN Force Range Compact Size Low Crosstalk Temperature Compensated Accessories BSC4A 4-Channel Analog Amplifier BSC4D 4-Channel

More information

T22. Torque transducer. Special features. Data sheet

T22. Torque transducer. Special features. Data sheet T22 Torque transducer Special features - Nominal (rated) torques 0.5 Nm, 1 Nm, 2 Nm, 5 Nm, Nm, Nm, 50 Nm, 0 Nm, 0 Nm, 500 Nm and 1 knm - Nominal (rated) rotational speed up to 000 rpm (depending on measuring

More information

Acceleration Sensor AS - 022

Acceleration Sensor AS - 022 1 Application Acceleration Sensor AS - 022 The acceleration sensor AS-022 is used for measurement of vibration acceleration. Fig. 1 Acceleration Sensor AS - 022 2 Measuring Principle 3 Technical Data Acceleration

More information

T40B. Torque Flange. Special features. Data sheet. Overall concept

T40B. Torque Flange. Special features. Data sheet. Overall concept T40B Torque Flange Special features - Nominal (rated) torques 50 N m, 0 N m, 200 N m, 500 N m, 1 kn m, 2 kn m, 3 kn m, 5 kn m and kn m - Nominal rated rotational speed up to 24000 rpm (depending on nominal

More information

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K. 4-170 Piezoelectric Accelerometer The CEC 4-170 accelerometer is a self-generating, piezoelectric accelerometer designed for medium temperature vibration measurement applications. This instrument provides

More information

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch] U10M Force Transducer Special features - Precise and robust tensile/compressive force transducer for static and dynamic measurement tasks - High lateral force and bending moment stability, the effect of

More information

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 370A Features Linearity error maximum 2 ppm 100

More information

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax: Load Cell F60X Bending beam load cell made of stainless steel, hermetically sealed. Approved up to 6000d R60 OIML. Level of protection IP 68. ATEX 94/9/CE version for hazardous area (option). Designed

More information

Force and weight measuring instruments

Force and weight measuring instruments JJ Force sensors and load cells JJ Measurement amplifiers JJ Mechanical and electronic accessories JJ Combination units JJ Force calibration systems Force and weight measuring instruments DS_Force_and_weight_measuring_instruments

More information

Sensor Datasheet Collection

Sensor Datasheet Collection ISO 9001 REGISTERED Specials are Our Standard Sensor Datasheet Collection CONTENTS HR-DRO: HIGH RESOLUTION DIGITAL READOUT 3 THE RELS FAMILY: ROD-END LOAD SENSORS 4-15 S-RELS SERIES: STANDARD ROD-END LOAD

More information

Model 3A Series 3-Axis Load Cell

Model 3A Series 3-Axis Load Cell Model 3A Series 3-Axis Load Cell 3-Axis Fx Fy Fz; Independent Bridges 20N to 500kN Force Range Compact Size Low Crosstalk Temperature Compensated Accessories Model 3A60A BSC4A 4-Channel Analog Amplifier

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Linear Proximity Sensor with High-accuracy Resolution Resolution is 0.05% of the maximum sensing distance. The model with a sensing distance of 1.2 mm ensures a resolution of

More information

Bend Sensor Technology Mechanical Application Design Guide Mechanical Application Design Guide

Bend Sensor Technology Mechanical Application Design Guide Mechanical Application Design Guide Bend Sensor Technology Mechanical Application Design Guide Mechanical Application Design Guide www.flexpoint.com Copyright 2015 Flexpoint Sensor Systems Page 1 of 10 2 Bend Sensor Technology Mechanical

More information

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES Rod End In-line Compression/Tension Load Cell DESCRIPTION The Model RGH In-Line load cells are high quality, stainless steel, rugged load cells capable of withstanding significant off-axis loads, making

More information

Models Tension/Compression Pancake Load Cell Model 3174 with tension base DESCRIPTION FEATURES

Models Tension/Compression Pancake Load Cell Model 3174 with tension base DESCRIPTION FEATURES Models 3174-3176 Model 3174 Model 3174 with tension base DESCRIPTION Models 3174, 3175, and 3176 are fatigue-resistant, low-profile tension and compression load cells that are well suited to materials

More information

Torque Sensor Accessories and Services

Torque Sensor Accessories and Services ------------------- Torque Sensor Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Speed sensors Shunt calibration modules and thermocouples Calibration services PCB

More information

Traffic Test system. Traffic System. Test System. Handy Scale Handy Vehicle weighing scale

Traffic Test system. Traffic System. Test System. Handy Scale Handy Vehicle weighing scale Traffic Test system 6 Traffic System Handy Scale Handy Vehicle weighing scale Test System Gait analysis system Gentle breeze pressure measuring system Shaking table measuring software system Electro-hydraulic

More information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.

More information

DESIGN OF MACHINE MEMBERS-I

DESIGN OF MACHINE MEMBERS-I Code No: R31035 R10 Set No: 1 JNT University Kakinada III B.Tech. I Semester Regular/Supplementary Examinations, Dec - 2014/Jan -2015 DESIGN OF MACHINE MEMBERS-I (Mechanical Engineering) Time: 3 Hours

More information

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators. Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 3000A Features ppm linearity 0 ppm offset Current

More information

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 600A Features Linearity error maximum 1.5 ppm Fluxgate,

More information

K3R110 ±50N; ±100N, ±200N; ±500N, ±1000N, ±2000N; ±5000N

K3R110 ±50N; ±100N, ±200N; ±500N, ±1000N, ±2000N; ±5000N K3R110 ±50N; ±100N, ±200N; Description The force sensor K3R110 is suitable for inspection tasks in quality assurance as well as in materials testing because of its compact design. This precision force

More information

Page 1 of 6 A Historical Perspective From Aristotle to Hawking Force & Its Effects Measurement Limitations The Strain Gage Sensor Designs Measuring Circuits Application & Installation Process Pressure

More information

Rotary Measurement Technology Incremental Encoders

Rotary Measurement Technology Incremental Encoders -20 to 60 C Temperature Shock/vibration resistant Short-circuit protection Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection

More information

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments Electrical Machine / Power Electronics PE-5000 Power Electronics Training System The PE-5000 Power Electronics Training System consists of 28 experimental modules, a three-phase squirrel cage motor, load,

More information

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Weighing System Evaluation Mounting DMS strain gauges (load cells), DMS amplifier

More information

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis Ultra-stable, high precision (ppm class) fluxgate technology DM Series current transducer for non-intrusive, isolated DC and AC current measurement up to 1500A Features Ø45mm aperture enabling large isolated

More information

Technical Manual. ETP-CLASSIC incl type R. Content

Technical Manual. ETP-CLASSIC incl type R. Content Technical Manual ETP-CLASSIC incl type R Content Technical parts description...2 Mounting/dismantling tips...4 Design suggestions...7 Tolerances...13 Central bolt...15 Torsional stiffness...16 Screw pitch

More information

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 2000A Features 20 ppm linearity 15 ppm offset 10V

More information

Distance-setting Photoelectric Sensor

Distance-setting Photoelectric Sensor Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use and High Performance Hyper LED mounted. Finest pin-point beam in the industry allows detection

More information

eddyncdt 3010 Non-Contact Displacement Measuring Systems

eddyncdt 3010 Non-Contact Displacement Measuring Systems Eddy current sensors for displacement, distance and position Eddy current and inductive measurement system and sensors with micrometer resolution for linear measurement and displacement, distance and position

More information

Rotary Position Technology Incremental Encoders

Rotary Position Technology Incremental Encoders -40 to 80 C Temperature Shock/vibration resistant Short-circuit protected Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection

More information

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en T10FS Torque Flange Data Sheet Special features Nominal (rated) torques: 100 NVm, 200 NVm, 500 NVm, 1 knvm, 2 knvm, 3 knvm, 5 knvm, 10 knvm Nominal speed from 12,000 rpm to 24,000 rpm Low rotor weights

More information

Technical capabilities of military calibration laboratories

Technical capabilities of military calibration laboratories Technical capabilities of military calibration laboratories Measurement domain Measuring range Measurement Remarks 3 ACCELERATION, VELOCITY AND DISTANCE Acceleration of Vibration - sensitivity (0,1 1000

More information

Product Information. ERN 1085 Incremental Rotary Encoder with Z1 Track

Product Information. ERN 1085 Incremental Rotary Encoder with Z1 Track Product Information ERN 1085 Incremental Rotary Encoder with Z1 Track 02/2018 ERN 1085 Rotary encoder with mounted stator coupling Compact dimensions Blind hollow shaft 6 mm Z1 track for sine commutation

More information

Dx: Digital Multi-Channel Telemetry System

Dx: Digital Multi-Channel Telemetry System Instrumented shaft with signal conditioning and transmitter unit (SCT) and inductive power supply Receiver, Control and Interface Unit (RCI) For measurements with rotating objects, a telemetry system for

More information

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10 Compression force transducer with Thin-film sensor Accuracy: 1 % Output signal: 4...20 ma; 2-wire, 0...10 VDC; 3-wire Optional Optional ATEX/IECEX II 2G Ex ib IIC T4/T3 for SIL3-Applications with 2-channel

More information

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators. DL000ID Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 3000A Features ppm linearity 6 ppm offset

More information

AC AC AC

AC AC AC AC104.01-10 AC104.01-100 AC104.01-500 Description The hermetic sealed industrial piezoelectric accelerometer model 104 is design to monitor the vibration in harsh industrial environment. It uses the industry

More information

Product Information ECI 1319S EQI 1331S. Absolute Rotary Encoders without Integral Bearing and with DRIVE-CLiQ Interface.

Product Information ECI 1319S EQI 1331S. Absolute Rotary Encoders without Integral Bearing and with DRIVE-CLiQ Interface. Product Information ECI 1319S EQI 1331S Absolute Rotary Encoders without Integral Bearing and with DRIVE-CLiQ Interface Firmware 15 12/2018 ECI 1319S, EQI 1331S Rotary encoders for absolute position values

More information

Making Basic Strain Measurements

Making Basic Strain Measurements IOtech Product Marketing Specialist steve.radecky@iotech.com Making Basic Strain Measurements using 24-Bit IOtech Hardware INTRODUCTION Strain gages are sensing devices used in a variety of physical test

More information

Introduction to Measurement Systems

Introduction to Measurement Systems MFE 3004 Mechatronics I Measurement Systems Dr Conrad Pace Page 4.1 Introduction to Measurement Systems Role of Measurement Systems Detection receive an external stimulus (ex. Displacement) Selection measurement

More information

MINIATURE METAL BELLOWS COUPLINGS

MINIATURE METAL BELLOWS COUPLINGS VERSATILE AND PRECISE. MINIATURE METAL BELLOWS COUPLINS SERIES MK 0.05 10 Nm THE ULTIMATE COUPLIN FROM 0.05 10 Nm BACKLASH FREE MINIATURE BELLOWS COUPLINS Areas of application: Ideal for precise transmission

More information

Simotec. 13.i

Simotec. 13.i Products: Framo 80 13.0 Products: Framo 80 13.1 Products: Structural Elements 100/120 13.2 Products: Pipe Shoes 13.3 Framo 80: Beam Section and Screw 13.4 Framo 80: Cantilever Bracket and End Support STA

More information

Force and strain sensors. Measure. Test. Control. Edition 2016

Force and strain sensors. Measure. Test. Control. Edition 2016 Force and strain sensors. Measure. Test. Control. Edition 2016 Force and strain sensors by Baumer combine tried and tested technology and sophisticated innovations. 1 Contents. Introduction 1 Product key

More information

n Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements

n Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements Potentiometric Displacement Sensor Miniature design Model 8709 Code: Delivery: Warranty: 8709 EN ex stock 24 months Application Potentiometric displacement sensors are used for direct, precise measurement

More information

Weighing Instruments

Weighing Instruments GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Weighing Instruments System Evaluation

More information

Load cell system fault finding guide (Application Note: Number AN1)

Load cell system fault finding guide (Application Note: Number AN1) Load cell system fault finding guide (Application Note: Number AN1) Table of Contents Basic checks 3 Basic load cell system............................ 3 Basic load cell resistance checks......................

More information

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants U15 Force transducer Special features - Tensile/compressive force transducer - Nominal (rated) forces 2.5 kn to 2.5 MN - lass 0.5 to ISO 376 in force measurement range between 10% and 100% of the nominal

More information

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable

More information

n Measuring range ,02 N m to N m n Clockwise and counter-clockwise torque n Low linearity deviation of ± 0.05 % F.S.

n Measuring range ,02 N m to N m n Clockwise and counter-clockwise torque n Low linearity deviation of ± 0.05 % F.S. Precision Torque Sensor Non-contact transmission for rotating applications Optional measurement of angle and speed Model 8661 Code: Delivery: Warranty: 2-3 weeks 24 months Application The 8661 precision

More information

Torque Measuring Flange

Torque Measuring Flange Force Torque Measuring Flange Digital Telemetry Based, Short-Design, Robust, High Accuracy Type 025DF... Type 025DF... torque measuring flanges operate on the strain gage principle. The integral, digital

More information

Model Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Model Tension/Compression Pancake Load Cell DESCRIPTION FEATURES Model 3173 Tension/Compression Pancake Load Cell DESCRIPTION The Model 3173 covers the lower capacity ranges of 200 pounds force to 3000 pounds force, while exhibiting the high performance characteristics

More information

RESOLUTE FS absolute optical encoder with Siemens DRIVE-CLiQ serial communications

RESOLUTE FS absolute optical encoder with Siemens DRIVE-CLiQ serial communications L-9517-9701-01-C RESOLUTE FS absolute optical encoder with Siemens DRIVE-CLiQ serial communications True absolute non-contact optical encoder system: no batteries required ISO 13849: 2015 Pld IEC 61508:

More information

Disc Gap Control DGC-2. Technical Manual

Disc Gap Control DGC-2. Technical Manual GB Disc Gap Control DGC-2 Technical Manual Contents Introduction Electronic unit... 1 Tracer valve... 1 Technical data... 2 Component layout... 4 Functions, electronic unit Stepper motor operation...

More information

Telemetrie-Messtechnik Schnorrenberg

Telemetrie-Messtechnik Schnorrenberg Telemetrie-Messtechnik Schnorrenberg CT16-Wheel User manual TMS Telemetrie-Messtechnik Schnorrenberg Dipl.-Ing. Werner Schnorrenberg Habichtweg 30, D-51429 Bergisch Gladbach, Tel: 02204-9815-52, Fax: 02204-9815-53,

More information

OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO

OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO. 990-60700-9801 GEOTECH INSTRUMENTS, LLC 10755 SANDEN DRIVE DALLAS, TEXAS 75238-1336 TEL: (214) 221-0000 FAX: (214) 343-4400

More information

New Long Stroke Vibration Shaker Design using Linear Motor Technology

New Long Stroke Vibration Shaker Design using Linear Motor Technology New Long Stroke Vibration Shaker Design using Linear Motor Technology The Modal Shop, Inc. A PCB Group Company Patrick Timmons Calibration Systems Engineer Mark Schiefer Senior Scientist Long Stroke Shaker

More information

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing The Modus M Series family of differential pressure transmitters measure low pressures, and feature a variety of analog signal outputs with low power consumption. A wide selection of standard pressure ranges

More information

A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training

A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training Following is an outline of the material covered in the training course. Each person

More information

World-Class Accuracy & Measurement Range (40 Conventional Models)

World-Class Accuracy & Measurement Range (40 Conventional Models) AC/DC CURRENT SENSOR CT6904 Ultra-High Performance AC/DC Current Sensor World-Class Accuracy & Measurement Range (40 Conventional Models) 500 A (rms) Rated for measurement of large currents 4 MHz (±3 db)

More information

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website:

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website: LCT100 Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com A. Basic Steps in Load Cell Testing using the LCT100: 1. Connect the load cell cable

More information

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en T22 Torque transducer Data Sheet Special features - Nominal (rated) torques N m, 10 N m, 20 N m, 0 N m, 100 N m, 200 N m, 00 N m and 1 kn m - Nominal (rated) rotational speeds of 9000 rpm to 16 000 rpm

More information

RDrive 85 servo motors. User manual

RDrive 85 servo motors. User manual INTRODUCTION Rozum Robotics has designed its RDrive (RD) servo motors to enable precision motion control in industrial and commercial applications. This manual is intended for technicians and engineers

More information

SRS SEALED ROTARY SENSORS

SRS SEALED ROTARY SENSORS SRS SEALED ROTARY SENSORS Innovation In Motion INNOVATION IN MOTION Penny+Giles SRS280 sealed rotary sensors and SRS880 submersible rotary sensors have been specially developed to provide maximum performance

More information

Kistler portable triaxial Force Plate

Kistler portable triaxial Force Plate Kistler portable triaxial Force Plate 1 Transducers Transducer - any device that converts one form of energy into another Sensors convert physical quantities into electrical signals electrical signals

More information

RESOLUTE absolute optical encoder with Siemens DRIVE-CLiQ serial communications

RESOLUTE absolute optical encoder with Siemens DRIVE-CLiQ serial communications L-9517-9524-04-D RESOLUTE absolute optical encoder with Siemens DRIVE-CLiQ serial communications True absolute non-contact optical encoder system: no batteries required Wide set-up tolerances for quick

More information

Model RH. Rod End In-line Tension Load Cell DESCRIPTION FEATURES

Model RH. Rod End In-line Tension Load Cell DESCRIPTION FEATURES Rod End In-line Tension Load Cell DESCRIPTION Model RH, with male and female threads, is a high output rod end load cell designed to be mounted inline to the load axis to measure tension. The outputs for

More information

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE RELAYS (60A type only) 0A PC board type 0A TM type 60A Screw terminal type 80A Connector type 300A Connector type FEATURES. High-, high-current

More information

CAPACITIVE SENSORS. Series KS. Key-Features:

CAPACITIVE SENSORS. Series KS. Key-Features: CAPACITIVE SENSORS Series KS Key-Features: Content: Introduction Applications...2 Technical Data Sensor Heads...3 Technical Drawing...4 Sensor Cabels...5 1 Channel Electronics...6 Description Electronics

More information

TESTING EQUIPMENT SHEAR STRENGTH PARAMETERS SOIL. established in 1972

TESTING EQUIPMENT SHEAR STRENGTH PARAMETERS SOIL.   established in 1972 SOIL www.alfatestusa.com established in 1972 SOIL Used to perform large range of Triaxial tests on soil samples to determine the strength parameters and the mechanical properties. Capable of performing:

More information