NERC System Protection and Control Task Force. Presented to the Western Protective Relay Conference Spokane, Washington October 20, 2004

Size: px
Start display at page:

Download "NERC System Protection and Control Task Force. Presented to the Western Protective Relay Conference Spokane, Washington October 20, 2004"

Transcription

1 NERC System Protection and Control Task Force Presented to the Western Protective Relay Conference Spokane, Washington October 20, 2004

2 Outline History Recommendations SPCTF Organization SPCTF Scope Comments from NERC Aug 14, 2003 Blackout Investigation Team Bob Stuart SPCTF Clarification of Ratings Bill Kennedy SPCTF Recommendations to NERC PC SPCTF Exception Criteria Jon Daume, Skip Williams Q&A - Panel 2

3 History WECC Blackouts 1996 Distance Relays were found to contribute January 1997 IEEE Computer Applications in Power Article by Carson Taylor and Dennis Erickson o Responses by Charles Henville and Charles Rogers in April 1997 Computer Applications in Power (letters to editor) August 14, 2003 Eastern Interconnection Blackouts U.S. Canada Power System Outage Task Force Reports on 11/19/03 and 4/4/04 NERC Investigation BOT Approved Recommendations on 2/10/04 July 13, 2004 NERC Technical Analysis Report ECAR Investigation Report on 2/16/04 3

4 History (Continued) All investigations into August 14, 2003 blackout found that Distance Relays tripping for non-fault conditions contributed to the blackout Much Criticism for Not Addressing Distance Relays after earlier blackouts NERC Planning Committee Formed a task force to address Relaying Issues relating to August 14, 2003 blackout SPCTF Scope was Approved by NERC on 3/25/04 SPCTF Staffed by NERC on 5/14/04 4

5 Recommendations NERC Recommendation 8a US Canada Power System Outage Task Force Recommendation 21a 5

6 SPCTF Organization Charles Rogers Consumers Energy Chairman (ECAR) Mark Carpenter TXU Electric Delivery Vice Chairman (ERCOT) John Mulhausen Florida Power and Light (FRCC) Al Darlington Tampa Electric (retired) (FRCC Alternate) Joe Burdis PJM Interconnection (MAAC) Bill Miller Excelon (MAIN) Deven Bahn WAPA (MAPP) Phil Tatro National Grid (NPCC) Phil Winston Georgia Power (SERC) Skip Williams AEP (ECAR Alternate) Fred Ipok Springfield, MO. SPP Dave Angell Idaho Power (WECC) Baj Agrawal APS (WECC Alternate) Jon Daume BPA (WECC Alternate) John Ciufo Hydro One (Canada - Eastern) Bill Kennedy Alberta Electric System Operator (Canada - Western) Jim Ingleson NYISO (ISO/RTO) Evan Sage PEPCO (IOU) Gary Kobet TVA (Federal) Keith Orsted American Transmission Company (TDU) Robert Stuart NEXANT, PGE (retired) (NERC Investigation Team) Tom Weidman Commonwealth Edison (retired) (NERC Investigation Team) Bob Cummings NERC Staff 6

7 SPCTF Scope Highlights Review and Report on Pros and Cons of Zone-3 Relays on Transmission Systems Review Zone-3 Relay Settings to Avoid Tripping on Load Review Requests for Exception and Report to PC Merits and Deficiencies of UVLS Review Region Evaluations of UVLS Feasibility and Benefits Review NERC Planning Standard III and Recommend Revisions as Appropriate General Review of Protection System Design to Improve Protection of System and Prevent/Mitigate Cascading Failures 7

8 SPCTF Activities To Date Clarified Definition of Rating Defined Zone 3 Further Defined Zone 3 Schedule and Assigned Major Roles to Regions Defined Temporary Exceptions and Technical Exceptions Developed draft Technical Exception Criteria Developed Technical Exception Reporting Form 8

9 NERC Investigation Team Bob Stuart NERC Investigation Team 9

10 NERC Investigation Team Zone 3 relays contributed to blackout Sammis Star 345 kv 16:05:57 escalated cascade East Lima Fostoria Central 345 kv trip accelerated cascade In total, 14 lines tripped by distance relay due to load encroachment 10

11 NERC Investigation Team Sammis Star tripped at 16:05:57 by Zone 3 Load Encroachment 120% emergency rating; 0.96 p.u. voltage (Sammis end); 27 degree line angle Zone 3 relay set for 200% of line to protect transformer 1500 MW of load dropped prior to line relaying would have contained disturbance to Cleveland 11

12 NERC Investigation Team Factors taken into consideration WECC Guidelines degree power factor angle p.u. voltage - margin recommended based on power flow studies Establish capability to ride thru severe disturbances - Give operators 10 to 15 minutes to drop load or reconfigure system Discussed with investigation team 12

13 NERC Investigation Team Conductor short term emergency ratings - 15 minute ratings based on more aggressive conditions - Achievable over 50% of time - normal ratings at 75% of line rating 10 to 15 minutes to reach 100 degrees C Assumed 15 to 25 % relay margin - CT and PT error - Relay error 15 to 25% margin above short term emergency rating will still allow small margin for 150% of summer emergency ratings 13

14 NERC Investigation Team Calculated relay settings for various lengths of lines Determined that line lengths above 75 miles would be difficult to set zone 3 relays assuming 150% setting Make relays less sensitive to load encroachment - Increasing maximum torque angle to 90 degrees - Activating load encroachment feature on modern relays - Installing blinders Asked two large utilities (represented on Investigation Team) to review proposed policy very small percentage had some mitigation to do may not be representative Policy intended to drive stake in ground more specific guidelines would have to be generated later 14

15 SPCTF Recommendations Bill Kennedy - AESO 15

16 SPCTF Clarification on Ratings NERC Recommendation 8a footnote states emergency ampere rating NERC PC Minutes March 24 suggests long time summer emergency ampere rating SPCTF Clarification (June 18) Highest seasonal ampere circuit rating that most closely approximates a 4-hour rating considering the lowest ampere rated device in the line 16

17 SPCTF Recommendations TPSO Transmission Protection System Owner Current Process to Address Only Zone-3 Relays Zone-3 Relays Defined As Remote Backup Relays (IEEE C Clause ) Inject Regions Into Zone-3 Process Build on Their Natural Relationships With the TPSO s TPSOs to Respond to Regions by Dates Established in NERC Recommendation 8a Regions to Assure That All TPSOs Have Responded and Respond to NERC 1 Month Later 17

18 SPCTF Recommendations (Continued) Establish Two Classes of Exception Temporary and Technical Temporary Exceptions to Request Delayed Schedule for Workforce or Construction Clearance Issues Must Include Proposed Schedule Technical Exceptions to Address Conditions Where Thermal Limits Are Not the Practical Limiting Condition SPCTF Developing Technical Exception Criteria SPCTF to Review All Exception Requests and Report to PC Denied Requests Must Be Mitigated in 1 Year 18

19 SPCTF Recommendations (Continued) All Other Load-responsive Relays to Be Reviewed and Addressed on a Schedule to Be Developed by SPCTF Exceptions to Be Reviewed by Regions Regions to Identify Critical Lines 115kv and Above for Inclusion in Review (Joint TF Recommendation 21a) All Recommendations were Approved by NERC PC on July 15,

20 Implementation Timeline for NERC Recommendation 8a Activities 12/31/2004 TPSOs Submit to Regions: - Certification of conformance to loadability - Violation mitigation (before 12/31/05) plans - Applications for exceptions 12/31/2005 TPSOs Submit to Regions: - Certification of full conformance - Implementation dates for outstanding violations 9/30/2004 TPSOs report to Regions on Zone 3 reviews 2/10/2004-9/30/2004 TPSOs review Zone 3 relays for conformance 9/30/ /31/2004 TPSOs mitigate violations 1/1/ /31/2005 TPSOs mitigate violations 2/10/2004 NERC Rec. 8A Issued by Board Today 10/31/2004 Regions Report TPSO completion of 9/30 review to SPCTF 1/31/2005 Regions report TPSO responses of 12/31/04 to SPCTF 2/1/2006 Regions report TPSO responses of 12/31/05 to SPCTF 20

21 SPCTF Exception Criteria Temporary Exceptions Technical Exceptions Realistic Circuit Ratings Achieve Minimum Acceptable Protection Network Topology Transmission System Must be Adequately Protected, and Distance Relaying Must also allow for Maximum Practical Load Flow Distance Relaying Must Not Contribute to Cascading Outages 21

22 Ratings and Technical Exceptions NERC Recommendation 8a refers to circuit thermal ratings SPCTF Clarified to highest seasonal 4-hour rating of most limiting circuit element Thermal ratings may not represent practical circuit ratings Technical Exceptions attempt to address the other practical circuit capabilities 22

23 Temporary Exceptions Permit delayed implementation because of workforce issues, construction outage constraints, or availability of replacement equipment Not intended to provide for budget relief TPSO must do all possible to mitigate with Existing Equipment Must Include Proposed Schedule for Mitigation 23

24 Technical Exceptions Twelve Individual Technical Exception Criteria Establishes lower margins for shorter-term circuit ratings (1) Address other system limitations that present more realistic actual system rating criteria (5) Establish ratings based on minimally-adequate protection (2) Natural system limitations due to topology (4) 24

25 Technical Exception #1 Utilize the 15-Minute Rating of the Transmission Line The tripping relay should not operate at or below 115% of the 15-minute winter emergency rating Assuming: 0.85 per unit voltage line phase angle of 30 degrees 25

26 Maximum Power Transfer Diagram Sending X S = 0 X L X R = 0 Receiving E S = 1.0 PU V S P R = V S V R X sinδ L V R E R = 1.0 PU The maximum real power that a transmission line can transfer occurs when the voltage angle across the line reaches 90º. 26

27 Maximum Power Transfer Capability 345 kv (2 X 1272 ACSR) Line Loadability Apparent Power (MVA) & St. Clair (MW) St. Clair Curve MW St. Clair MVA S 1.5xWE Ss (Vs=1 δ=90 ) Line Length (miles) 27

28 Derivation of the Exception Equation V P = P = V S 2 X L V R X sinδ L VS VS VR Q = cos X X ( o δ ) The real and reactive currents are equal at maximum power transfer Q = V L 2 X L 2 L 28 I total = 2 I real I total 2 V = 3 X L

29 Technical Exception # 2, 3 and 4 The protective relays only need to accommodate the power transfer capability of a transmission line #2 Line X only, 1.00 p.u. V Recertify when line is changed #3 Line and breaker interrupter rating, 1.05 p.u. V Recertify when breaker is underrated or changed #4 Line and actual source impedance, 1.05 p.u. V Recertify annually 29

30 Technical Exception #5 Special Considerations for Series- Compensated Lines Tripping relay should not operate at or below the greater of: times the highest emergency rating of the series capacitor 2. I total (calculated under Exception 2, 3, or 4 using full line inductive reactance) assuming 0.85 per unit voltage line phase angle of 30º 30

31 Technical Exceptions Part 2 Skip Williams AEP 31

32 Technical Exception #6 Weak Source Systems The tripping relay should not operate at or below 1.15 times I = I max Assuming: fault 0.85 per unit voltage at a load phase angle of 30 degrees where I max is the maximum end of line three-phase fault current magnitude. 32

33 Technical Exception 6 - Drawing OPEN FAULT TRANSMISSION SYSTEM R LOAD CENTER Weak Source Systems 33

34 Technical Exception #7 Long Line Relay Loadability Long line relay loadability can be adjusted as long as ALL of the following conditions are met: 1. Most sensitive tripping relay set 125% of total line impedance 2. MTA set as close to 90 degrees (sanctioned by manufacturer) 34

35 Technical Exception #7 (cont.) 3. Short-term emergency rating (I emergency ) of line is equal to or less than: Vrelay cos( MTA Θline) I emergency = Zline cos( MTA 30 ) Where V is the nominal line-to-line voltage and Z line is the impedance of the line in ohms 4. I emergency used in all planning and operational modeling for STE Rating (15-min. or most closely approx. 15-min. rating) 35

36 Technical Exception #7 (cont.) 5. No current or subsequent planning contingency analyses identify any conditions where the recoverable flow is greater than I emergency 6. Transmission Operators take immediate remedial steps, including dropping load, if current reaches I emergency If any of these conditions are violated, then the condition must be fully mitigated to avoid the loadability issue 36

37 Technical Exception 7 - Drawing X Z RELAY 1.25 Z LINE Z LINE MTA 30 0 R Z RELAY 30 LINE Long Line Loadability 37

38 Technical Exception 8 Three (or more) Terminal Lines Similar to Exception 7, except considers apparent impedance to the most distant line terminal, instead of simply considering line impedance Includes lines with significant taps 38

39 Technical Exception #9 Generation Remote to Load The tripping relay should not operate for 1.15 times the maximum current, representing twice the aggregate generator MVA capability, assuming 0.85 per unit voltage line phase angle of 30 degrees 39

40 Technical Exception 9 - Drawings GENERATION CENTER LOAD BUS A R R OPEN OPEN LOAD BUS B LOAD BUS C LOAD CENTER R Generation Connected to System Multiple Lines 40

41 Technical Exception #10 Load Remote to Generation The tripping relay should not operate for 1.15 times the maximum current flow as calculated by the TPSO assuming 0.85 per unit voltage line phase angle of 30 degrees 41

42 Technical Exception 10 - Drawing GENERATION CENTER LOAD BUS A R R LOAD BUS B LOAD BUS C LOAD CENTER R Load Remote to Generation 42

43 Technical Exception #11 Remote Cohesive Load Center The tripping relay should not operate for 1.15 times the maximum current flow as calculated by the transmission owner assuming 0.85 per unit voltage a line phase angle of 30 degrees 43

44 Technical Exception 11 - Drawing TRANSMISSION SYSTEM R R LOAD CENTER R Remote Cohesive Load Center 44

45 Technical Exception #12 Cohesive Load Center Remote to Transmission System The Tripping relay should not operate for 1.15 times the maximum current flow as calculated by the TPSO assuming 0.85 per unit voltage line phase angle of 30 degrees 45

46 Technical Exception 12 - Drawing TRANSMISSION SYSTEM R R LOAD CENTER R Cohesive Load Center Remote to Transmissions System 46

47 Wrapup and Conclusions Dave Angell 47

48 Some Possible Mitigation Methods Must Adequately Protect System Disable Unnecessary Protective Elements Increase Distance Relay Maximum Torque Angle Utilize load-tolerant relay characteristics Utilize Transfer Trip for Remote Backup Transmission System modifications to Facilitate Protection Others? 48

49 SPCTF Next Distance Relay Activities All other load responsive relays (230 kv and above, and lower voltage level critical facilities) must also not limit practical loading capability. Includes Zone 2 relays, pilot-scheme relays, and overcurrent relays DCB Carrier Schemes can improperly operate on through load if lines are consuming significant real and reactive power Will have a different schedule for analysis, reporting, and mitigation Must adequately protect electrical system! 49

50 SPCTF Documents Approved SPCTF Documents may be found on the NERC web site at: Official Reports on the August 14, 2003 Blackout may be found on the NERC web site at: 50

51 SPCTF Contacts For detailed questions or suggestions, please contact Bob Cummings Charles Rogers Mark Carpenter Any other SPCTF member We Need everyone s help for us to do the best possible job! 51

52 NERC SPCTF Q&A Panel Members All Available SPCTF Members 52

Summary of Relaying Reviews Reporting

Summary of Relaying Reviews Reporting Revised Attachment B (Agenda Item 6) Summary of Relaying Reviews -- 12-31-04 Reporting This form shall be used without modification to provide a summary of relaying reviews performed by each Transmisission

More information

Methods to Increase Line Relay Loadability

Methods to Increase Line Relay Loadability Methods to Increase Line Relay Loadability A Technical Document Prepared by the System Protection and Control Task Force of the NERC Planning Committee For the North American Electric Reliability Council

More information

Switch-on-to-Fault Schemes in the Context of Line Relay Loadability

Switch-on-to-Fault Schemes in the Context of Line Relay Loadability Switch-on-to-Fault Schemes in the Context of Line Relay Loadability A Technical Document Prepared by the System Protection and Control Task Force Of the North American Electric Reliability Council June

More information

NERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell

NERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell Power Plant and Transmission System Protection Coordination Phase Distance (21) and Voltage-Controlled or Voltage-Restrained Overcurrent Protection (51V) NERC Protection Coordination Webinar Series June

More information

Protection System Review Program

Protection System Review Program Protection System Review Program Beyond Zone 3 North American Electric Reliability Council Prepared by the System Protection and Control Task Force of the NERC Planning Committee August 2005 Copyright

More information

Unit Auxiliary Transformer Overcurrent Relay Loadability During a Transmission Depressed Voltage Condition

Unit Auxiliary Transformer Overcurrent Relay Loadability During a Transmission Depressed Voltage Condition Unit Auxiliary Transformer Overcurrent Relay Loadability During a Transmission Depressed Voltage Condition NERC System Protection and Control Subcommittee March 2016 NERC Report Title Report Date I Table

More information

Standard Development Timeline

Standard Development Timeline Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard is adopted by the Board of Trustees. Description

More information

Transmission System Phase Backup Protection

Transmission System Phase Backup Protection Reliability Guideline Transmission System Phase Backup Protection NERC System Protection and Control Subcommittee Draft for Planning Committee Approval June 2011 Table of Contents 1. Introduction and Need

More information

Relay Loadability Exceptions

Relay Loadability Exceptions elay Loadability Exceptions Determination and Application of Practical elaying Loadability atings North American Electric eliability Council Prepared by the System Protection and Control Task Force of

More information

(Circuits Subject to Requirements R1 R5) Generator Owner with load-responsive phase protection systems as described in

(Circuits Subject to Requirements R1 R5) Generator Owner with load-responsive phase protection systems as described in A. Introduction 1. Title: Transmission Relay Loadability 2. Number: PRC-023-3 3. Purpose: Protective relay settings shall not limit transmission loadability; not interfere with system operators ability

More information

Relay Loadability Exceptions

Relay Loadability Exceptions elay Loadability Exceptions Determination and Application of Practical elaying Loadability atings ersion 1.1 November 2004 Prepared by the System Protection and Control Task Force of the North American

More information

1

1 Guidelines and Technical Basis Introduction The document, Power Plant and Transmission System Protection Coordination, published by the NERC System Protection and Control Subcommittee (SPCS) provides extensive

More information

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75 PRC-025-1 Introduction The document, Power Plant and Transmission System Protection Coordination, published by the NERC System Protection and Control Subcommittee (SPCS) provides extensive general discussion

More information

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76 PRC-025-1 Introduction The document, Power Plant and Transmission System Protection Coordination, published by the NERC System Protection and Control Subcommittee (SPCS) provides extensive general discussion

More information

Final ballot January BOT adoption February 2015

Final ballot January BOT adoption February 2015 Standard PRC-024-21(X) Generator Frequency and Voltage Protective Relay Settings Standard Development Timeline This section is maintained by the drafting team during the development of the standard and

More information

PRC Disturbance Monitoring and Reporting Requirements

PRC Disturbance Monitoring and Reporting Requirements Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Development Steps Completed

More information

PRC Generator Relay Loadability. A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1

PRC Generator Relay Loadability. A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1 PRC-025-1 Generator Relay Loadability A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1 Purpose: To set load-responsive protective relays associated with generation Facilities

More information

NERC Protection Coordination Webinar Series June 9, Phil Tatro Jon Gardell

NERC Protection Coordination Webinar Series June 9, Phil Tatro Jon Gardell Power Plant and Transmission System Protection Coordination GSU Phase Overcurrent (51T), GSU Ground Overcurrent (51TG), and Breaker Failure (50BF) Protection NERC Protection Coordination Webinar Series

More information

Industry Webinar Draft Standard

Industry Webinar Draft Standard Industry Webinar Draft Standard Project 2010-13.2 Phase 2 of Relay Loadability: Generation PRC-025-1 Generator Relay Loadability December 13, 2012 Agenda Welcome, Introductions and Administrative NERC

More information

PRC Generator Relay Loadability. A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1

PRC Generator Relay Loadability. A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1 A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1 Purpose: To set load-responsive protective relays associated with generation Facilities at a level to prevent unnecessary tripping

More information

Power Plant and Transmission System Protection Coordination of-field (40) and Out-of. of-step Protection (78)

Power Plant and Transmission System Protection Coordination of-field (40) and Out-of. of-step Protection (78) Power Plant and Transmission System Protection Coordination Loss-of of-field (40) and Out-of of-step Protection (78) System Protection and Control Subcommittee Protection Coordination Workshop Phoenix,

More information

Determination of Practical Transmission Relaying Loadability Settings Implementation Guidance for PRC System Protection and Control Subcommittee

Determination of Practical Transmission Relaying Loadability Settings Implementation Guidance for PRC System Protection and Control Subcommittee Determination of Practical Transmission Relaying Loadability Settings Implementation Guidance for PRC-023-4 System Protection and Control Subcommittee December 2017 NERC Report Title Report Date I Table

More information

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction. See the Implementation Plan for PRC

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction. See the Implementation Plan for PRC A. Introduction 1. Title: Generator Frequency and Voltage Protective Relay Settings 2. Number: PRC-024-2 3. Purpose: Ensure Generator Owners set their generator protective relays such that generating units

More information

Wind Power Facility Technical Requirements CHANGE HISTORY

Wind Power Facility Technical Requirements CHANGE HISTORY CHANGE HISTORY DATE VERSION DETAIL CHANGED BY November 15, 2004 Page 2 of 24 TABLE OF CONTENTS LIST OF TABLES...5 LIST OF FIGURES...5 1.0 INTRODUCTION...6 1.1 Purpose of the Wind Power Facility Technical

More information

NERC Protection Coordination Webinar Series June 30, Dr. Murty V.V.S. Yalla

NERC Protection Coordination Webinar Series June 30, Dr. Murty V.V.S. Yalla Power Plant and Transmission System Protection ti Coordination Loss-of-Field (40) and Out-of of-step Protection (78) NERC Protection Coordination Webinar Series June 30, 2010 Dr. Murty V.V.S. Yalla Disclaimer

More information

Power Plant and Transmission System Protection Coordination

Power Plant and Transmission System Protection Coordination Technical Reference Document Power Plant and Transmission System Protection Coordination NERC System Protection and Control Subcommittee Revision 1 July 2010 Table of Contents 1. Introduction... 1 1.1.

More information

Agenda Notes for 4 th Meeting of Sub Group in respect of Preparation of Reliability Standards for Protection System and Communication System

Agenda Notes for 4 th Meeting of Sub Group in respect of Preparation of Reliability Standards for Protection System and Communication System Agenda Notes for 4 th Meeting of Sub Group in respect of Preparation of Reliability Standards for Protection System and Communication System Meeting Date: 27.03.2017 Time: 1430 Hrs Venue: NRPC Conference

More information

NERC Requirements for Setting Load-Dependent Power Plant Protection: PRC-025-1

NERC Requirements for Setting Load-Dependent Power Plant Protection: PRC-025-1 NERC Requirements for Setting Load-Dependent Power Plant Protection: PRC-025-1 Charles J. Mozina, Consultant Beckwith Electric Co., Inc. www.beckwithelectric.com I. Introduction During the 2003 blackout,

More information

FACILITY RATINGS METHOD TABLE OF CONTENTS

FACILITY RATINGS METHOD TABLE OF CONTENTS FACILITY RATINGS METHOD TABLE OF CONTENTS 1.0 PURPOSE... 2 2.0 SCOPE... 3 3.0 COMPLIANCE... 4 4.0 DEFINITIONS... 5 5.0 RESPONSIBILITIES... 7 6.0 PROCEDURE... 8 6.4 Generating Equipment Ratings... 9 6.5

More information

Unit Auxiliary Transformer (UAT) Relay Loadability Report

Unit Auxiliary Transformer (UAT) Relay Loadability Report Background and Objective Reliability Standard, PRC 025 1 Generator Relay Loadability (standard), developed under NERC Project 2010 13.2 Phase 2 of Relay Loadability: Generation, was adopted by the NERC

More information

Power Plant and Transmission System Protection Coordination

Power Plant and Transmission System Protection Coordination Agenda Item 5.h Attachment 1 A Technical Reference Document Power Plant and Transmission System Protection Coordination Draft 6.9 November 19, 2009 NERC System Protection and Control Subcommittee November

More information

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements Division 502 Technical Applicability 1(1) Section 502.1 applies to: Expedited Filing Draft August 22, 2017 the legal owner of an aggregated generating facility directly connected to the transmission system

More information

Considerations for Power Plant and Transmission System Protection Coordination

Considerations for Power Plant and Transmission System Protection Coordination Considerations for Power Plant and Transmission System Protection Coordination Technical Reference Document Revision 2 System Protection and Control Subcommittee July 2015 I Table of Contents Preface...

More information

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction A. Introduction 1. Title: Generator Frequency and Voltage Protective Relay Settings 2. Number: PRC-024-1 3. Purpose: Ensure Generator Owners set their generator protective relays such that generating units

More information

Setting and Verification of Generation Protection to Meet NERC Reliability Standards

Setting and Verification of Generation Protection to Meet NERC Reliability Standards 1 Setting and Verification of Generation Protection to Meet NERC Reliability Standards Xiangmin Gao, Tom Ernst Douglas Rust, GE Energy Connections Dandsco LLC. Abstract NERC has recently published several

More information

AUTOMATIC CALCULATION OF RELAY SETTINGS FOR A BLOCKING PILOT SCHEME

AUTOMATIC CALCULATION OF RELAY SETTINGS FOR A BLOCKING PILOT SCHEME AUTOMATIC CALCULATION OF RELAY SETTINGS FOR A BLOCKING PILOT SCHEME Donald M. MACGREGOR Electrocon Int l, Inc. USA eii@electrocon.com Venkat TIRUPATI Electrocon Int l, Inc. USA eii@electrocon.com Russell

More information

System Protection and Control Subcommittee

System Protection and Control Subcommittee Power Plant and Transmission System Protection Coordination Volts Per Hertz (24), Undervoltage (27), Overvoltage (59), and Under/Overfrequency (81) Protection System Protection and Control Subcommittee

More information

Central Hudson Gas & Electric Corporation. Transmission Planning Guidelines

Central Hudson Gas & Electric Corporation. Transmission Planning Guidelines Central Hudson Gas & Electric Corporation Transmission Planning Guidelines Version 4.0 March 16, 2016 Version 3.0 March 16, 2009 Version 2.0 August 01, 1988 Version 1.0 June 26, 1967 Table of Contents

More information

GridLiance Reliability Criteria

GridLiance Reliability Criteria GridLiance Reliability Criteria Planning Department March 1, 2018 FOREWORD The GridLiance system is planned, designed, constructed, and operated to assure continuity of service during system disturbances

More information

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form) IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form) Transmission Provider: IDAHO POWER COMPANY Designated Contact Person: Jeremiah Creason Address: 1221 W. Idaho Street, Boise ID 83702 Telephone

More information

DUKE ENERGY CAROLINAS TRANSMISSION SYSTEM PLANNING GUIDELINES. Transmission Planning

DUKE ENERGY CAROLINAS TRANSMISSION SYSTEM PLANNING GUIDELINES. Transmission Planning DUKE ENERGY CAROLINAS TRANSMISSION SYSTEM PLANNING GUIDELINES Transmission Planning TABLE OF CONTENTS I. SCOPE 1 II. TRANSMISSION PLANNING OBJECTIVES 2 III. PLANNING ASSUMPTIONS 3 A. Load Levels 3 B. Generation

More information

Generation and Load Interconnection Standard

Generation and Load Interconnection Standard Generation and Load Interconnection Standard Rev. 0 DRAFT Name Signature Date Prepared: Approved: VP Acceptance APEGGA Permit to Practice P-08200 TABLE OF CONTENTS 1.0 INTRODUCTION...5 1.1 Purpose...5

More information

Generation and Load Interconnection Standard

Generation and Load Interconnection Standard Generation and Load Interconnection Standard Rev. 0A DRAFT Name Signature Date Prepared: Approved: VP Acceptance APEGGA Permit to Practice P-08200 TABLE OF CONTENTS 1.0 INTRODUCTION...5 1.1 Purpose...5

More information

Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS

Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS S1. Standard Interconnection Methods with Typical Circuit Configuration for Single or Multiple Units Note: The protection requirements

More information

NPCC Regional Reliability Reference Directory # 12. Underfrequency Load Shedding Program Requirements

NPCC Regional Reliability Reference Directory # 12. Underfrequency Load Shedding Program Requirements NPCC Regional Reliability Reference Directory # 12 Under frequency Load Shedding Program Requirements Task Force on System Studies Revision Review Record: June 26 th, 2009 March 3 rd, 2010 Adopted by the

More information

Recently, the SS38 Working Group on Inter-Area Dynamic Analysis completed two study reports on behalf of the UFLS Regional Standard Drafting Team.

Recently, the SS38 Working Group on Inter-Area Dynamic Analysis completed two study reports on behalf of the UFLS Regional Standard Drafting Team. December 7 th, 2010 NPCC Full Member Committee; Please find attached a draft revised NPCC Regional Reliability Directory #12 Underfrequency Load Shedding Program Requirements and a draft revised NPCC UFLS

More information

MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology

MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology For NERC Standard FAC-008-3 Version 3.4 1 Contents 1. Scope... 3 2. Establishment and Communication of Facility Ratings:... 3 2.1.

More information

Document C-29. Procedures for System Modeling: Data Requirements & Facility Ratings. January 5 th, 2016 TFSS Revisions Clean Open Process Posting

Document C-29. Procedures for System Modeling: Data Requirements & Facility Ratings. January 5 th, 2016 TFSS Revisions Clean Open Process Posting Document C-29 Procedures for System Modeling: January 5 th, 2016 TFSS Revisions Clean Open Process Posting Prepared by the SS-37 Working Group on Base Case Development for the Task Force on System Studies.

More information

Introduction. Disclaimer

Introduction. Disclaimer Determination and Application of Practical elaying Loadability atings System Protection and Control Task Force Of the NEC Planning Committee ersion 1.0 January 9, 2007 ntroduction Table of Contents Disclaimer...

More information

Standard VAR-002-2b(X) Generator Operation for Maintaining Network Voltage Schedules. 45-day Formal Comment Period with Initial Ballot June July 2014

Standard VAR-002-2b(X) Generator Operation for Maintaining Network Voltage Schedules. 45-day Formal Comment Period with Initial Ballot June July 2014 Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Development Steps Completed

More information

Table of Contents. Introduction... 1

Table of Contents. Introduction... 1 Table of Contents Introduction... 1 1 Connection Impact Assessment Initial Review... 2 1.1 Facility Design Overview... 2 1.1.1 Single Line Diagram ( SLD )... 2 1.1.2 Point of Disconnection - Safety...

More information

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements Applicability 1(1) Section 502.1 applies to the ISO, and subject to the provisions of subsections 1(2), (3) and (4) to any: (a) a new wind aggregated generating facility to be connected to the transmission

More information

Transmission Interconnection Requirements for Inverter-Based Generation

Transmission Interconnection Requirements for Inverter-Based Generation Transmission Requirements for Inverter-Based Generation June 25, 2018 Page 1 Overview: Every generator interconnecting to the transmission system must adhere to all applicable Federal and State jurisdictional

More information

ITC Holdings Planning Criteria Below 100 kv. Category: Planning. Eff. Date/Rev. # 12/09/

ITC Holdings Planning Criteria Below 100 kv. Category: Planning. Eff. Date/Rev. # 12/09/ ITC Holdings Planning Criteria Below 100 kv * Category: Planning Type: Policy Eff. Date/Rev. # 12/09/2015 000 Contents 1. Goal... 2 2. Steady State Voltage & Thermal Loading Criteria... 2 2.1. System Loading...

More information

Standard VAR-002-2b(X) Generator Operation for Maintaining Network Voltage Schedules

Standard VAR-002-2b(X) Generator Operation for Maintaining Network Voltage Schedules Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Development Steps Completed

More information

Standard VAR-002-2b(X) Generator Operation for Maintaining Network Voltage Schedules

Standard VAR-002-2b(X) Generator Operation for Maintaining Network Voltage Schedules Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Development Steps Completed

More information

System Protection and Control Subcommittee

System Protection and Control Subcommittee Power Plant and Transmission System Protection Coordination Reverse Power (32), Negative Sequence Current (46), Inadvertent Energizing (50/27), Stator Ground Fault (59GN/27TH), Generator Differential (87G),

More information

System Operating Limit Definition and Exceedance Clarification

System Operating Limit Definition and Exceedance Clarification System Operating Limit Definition and Exceedance Clarification The NERC-defined term System Operating Limit (SOL) is used extensively in the NERC Reliability Standards; however, there is much confusion

More information

NERC / TVA STABILITY WORKSHOP

NERC / TVA STABILITY WORKSHOP NERC / TVA STABILITY WORKSHOP CHATTANOOGA, TN MAY 23-24, 24, 2007 Robert Dintelman Utility System Efficiencies, Inc. WECC Transmission System 1996 Western Outages July 2, 1996 July 3, 1996 August 10, 1996

More information

MANITOBA HYDRO TRANSMISSION SYSTEM INTERCONNECTION REQUIREMENTS. July 2016 Version 4

MANITOBA HYDRO TRANSMISSION SYSTEM INTERCONNECTION REQUIREMENTS. July 2016 Version 4 MANITOBA HYDRO TRANSMISSION SYSTEM INTERCONNECTION REQUIREMENTS July 2016 Version 4 This page intentionally blank LEGISLATIVE AUTHORITY Section 15.0.3(1) of The Manitoba Hydro Act (C.C.S.M. c. H190) authorizes

More information

1200 MW Fault Induced Solar Photovoltaic Resource Interruption Disturbance Report

1200 MW Fault Induced Solar Photovoltaic Resource Interruption Disturbance Report 1200 MW Fault Induced Solar Photovoltaic Resource Interruption Disturbance Report Rich Bauer Associate Director Reliability Risk Management / Event Analysis Mid C Seminar July 19, 2017 Western Interconnection

More information

LONG-RANGE TRANSMISSION PLAN

LONG-RANGE TRANSMISSION PLAN LONG-RANGE TRANSMISSION PLAN 2011-2020 Transmission and Substation Engineering Department August 15, 2011 TABLE OF CONTENTS EXECUTIVE SUMMARY Page i I. OVERVIEW 1 A. Factors Affecting the Long Range Transmission

More information

E N G I N E E R I N G M A N U A L

E N G I N E E R I N G M A N U A L 1 1 1.0 PURPOSE The purpose of this document is to define policy and provide engineering guidelines for the AP operating companies (Monongahela Power Company, The Potomac Edison Company, and West Penn

More information

NERC Protection Coordination Webinar Series July 15, Jon Gardell

NERC Protection Coordination Webinar Series July 15, Jon Gardell Power Plant and Transmission System Protection Coordination Reverse Power (32), Negative Sequence Current (46), Inadvertent Energizing (50/27), Stator Ground Fault (59GN/27TH), Generator Differential (87G),

More information

Kansas City Power & Light Company. Transmission Facility Rating Methodology

Kansas City Power & Light Company. Transmission Facility Rating Methodology Company Prepared by: KCP&L Transmission Planning December 6, 2017 Table of Contents 1. Purpose...4 2. Generator Rating Methodology...4 3....4 3.1. Equipment Rating Methodology...4 3.2. Items considered

More information

Arizona Public Service Company and the Transmission Partnership for National Electric Power Company of Jordan

Arizona Public Service Company and the Transmission Partnership for National Electric Power Company of Jordan Arizona Public Service Company and the Transmission Partnership for National Electric Power Company of Jordan Mark Hackney October 5-8, 2009 Amman, Jordan Energy Control Center Layout 2 Energy Control

More information

Voltage Control with Distributed Generators to Enhance Voltage Stability

Voltage Control with Distributed Generators to Enhance Voltage Stability Advanced Electricity Infrastructure Workshop Global Climate & Energy Project STANFORD UNIVERSITY, Nov. 1~2, 2007 Voltage Control with Distributed Generators to Enhance Voltage Stability Presenter: Fangxing

More information

Industry Webinar. Reactive Power Planning. NERC System Analysis and Modeling Subcommittee (SAMS) March 2017

Industry Webinar. Reactive Power Planning. NERC System Analysis and Modeling Subcommittee (SAMS) March 2017 Industry Webinar Reactive Power Planning NERC System Analysis and Modeling Subcommittee (SAMS) March 2017 Webinar Topics Reliability Guideline on Reactive Power Planning Webinar Topics Fundamentals of

More information

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications 1 1 1 1 1 1 1 1 0 1 0 1 0 1 Reliability Guideline: Generating Unit Operations During Complete Loss of Communications Preamble: It is in the public interest for the North American Electric Reliability Corporation

More information

ELEMENTS OF FACTS CONTROLLERS

ELEMENTS OF FACTS CONTROLLERS 1 ELEMENTS OF FACTS CONTROLLERS Rajiv K. Varma Associate Professor Hydro One Chair in Power Systems Engineering University of Western Ontario London, ON, CANADA rkvarma@uwo.ca POWER SYSTEMS - Where are

More information

ESB National Grid Transmission Planning Criteria

ESB National Grid Transmission Planning Criteria ESB National Grid Transmission Planning Criteria 1 General Principles 1.1 Objective The specific function of transmission planning is to ensure the co-ordinated development of a reliable, efficient, and

More information

Implementation Plan Project Modifications to PRC Reliability Standard PRC-025-2

Implementation Plan Project Modifications to PRC Reliability Standard PRC-025-2 Project 2016-04 Modifications to PRC-025-1 Reliability Standard PRC-025-2 Applicable Standard PRC Generator Relay Loadability Requested Retirement PRC 025 1 Generator Relay Loadability Prerequisite Standard

More information

August 14, 2003 Blackout. 3 Interconnections / 10 NERC Regions. NERC Control Areas. NERC Reliability Coordinators. Overview

August 14, 2003 Blackout. 3 Interconnections / 10 NERC Regions. NERC Control Areas. NERC Reliability Coordinators. Overview Overview August 14, 2003 Blackout Summary based on NERC reports, Power System Engineering Research Center Report, and DOE Reports Overview of power system and reliability Pre-outage conditions on August

More information

Embedded Generation Connection Application Form

Embedded Generation Connection Application Form Embedded Generation Connection Application Form This Application Form provides information required for an initial assessment of the Embedded Generation project. All applicable sections must be completed

More information

Application for A Sub-harmonic Protection Relay. ERLPhase Power Technologies

Application for A Sub-harmonic Protection Relay. ERLPhase Power Technologies Application for A Sub-harmonic Protection Relay ERLPhase Power Technologies 1 Outline Introduction System Event at Xcel Energy Event Analysis Microprocessor based relay hardware architecture Sub harmonic

More information

The Use of VSC-Based BtB as Grid Shock Absorber

The Use of VSC-Based BtB as Grid Shock Absorber The Use of VSC-Based BtB as Grid Shock Absorber Abdel-Aty Edris aedris@epri.com IEEE GM July 08 Voltage-Sourced Converter A Building Block for New Transmission Controllers Vo Transm ission lineline Transm

More information

BED INTERCONNECTION TECHNICAL REQUIREMENTS

BED INTERCONNECTION TECHNICAL REQUIREMENTS BED INTERCONNECTION TECHNICAL REQUIREMENTS By Enis Šehović, P.E. 2/11/2016 Revised 5/19/2016 A. TABLE OF CONTENTS B. Interconnection Processes... 2 1. Vermont Public Service Board (PSB) Rule 5.500... 2

More information

NERC Protection Coordination Webinar Series June 23, Phil Tatro

NERC Protection Coordination Webinar Series June 23, Phil Tatro Power Plant and Transmission System Protection Coordination Volts Per Hertz (24), Undervoltage (27), Overvoltage (59), and Under/Overfrequency (81) Protection NERC Protection Coordination Webinar Series

More information

Final ballot January BOT adoption February 2015

Final ballot January BOT adoption February 2015 Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Development Steps Completed

More information

Central East Voltage and Stability Analysis for Marcy FACTS Project Phase I

Central East Voltage and Stability Analysis for Marcy FACTS Project Phase I Prepared by NYISO Operations Engineering 1. INTRODUCTION Central East Voltage and Stability Analysis for The Marcy Flexible AC Transmission System (FACTS) project is a joint technology partnership between

More information

Endorsed Assignments from ERS Framework

Endorsed Assignments from ERS Framework ERSTF Completion Endorsed Assignments from ERS Framework Ref Number Title ERS Recommendatio n Ongoing Responsibility 1 Synch Inertia at Interconnection Level Measure 2 Initial Frequency Deviation Measure

More information

Jonathan (Xiangmin) Gao - GE Grid Solutions Douglas Rust - Dandsco LLC Presented by: Tom Ernst GE Grid Solutions

Jonathan (Xiangmin) Gao - GE Grid Solutions Douglas Rust - Dandsco LLC Presented by: Tom Ernst GE Grid Solutions Jonathan (Xiangmin) Gao - GE Grid Solutions Douglas Rust - Dandsco LLC Presented by: Tom Ernst GE Grid Solutions PRC-001: System protection coordination PRC-019: Coordination with voltage regulating control

More information

Inverter-Based Resource Disturbance Analysis

Inverter-Based Resource Disturbance Analysis Inverter-Based Resource Disturbance Analysis Key Findings and Recommendations Informational Webinar February 15, 2018 August 16, 2016 Blue Cut Fire Disturbance Key Findings and Recommendations 2 Western

More information

Grid codes and wind farm interconnections CNY Engineering Expo. Syracuse, NY November 13, 2017

Grid codes and wind farm interconnections CNY Engineering Expo. Syracuse, NY November 13, 2017 Grid codes and wind farm interconnections CNY Engineering Expo Syracuse, NY November 13, 2017 Purposes of grid codes Grid codes are designed to ensure stable operating conditions and to coordinate the

More information

Tampa Electric Company Facility Rating Methodology Approved 11/20/2018

Tampa Electric Company Facility Rating Methodology Approved 11/20/2018 Tampa Electric Company Facility Rating Methodology Approved 11/20/2018 Effective Date: 12/01/2018 Responsible Department: System Planning Review Cycle: 3 Years Last Date Reviewed: 11/16/2018 Next Planned

More information

PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016

PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016 PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016 Prepared by System Planning Division Transmission Planning Department PJM 2016 Table of Contents Table of Contents Approval...6

More information

Southern Company Interconnection Requirements for Inverter-Based Generation

Southern Company Interconnection Requirements for Inverter-Based Generation Southern Company Interconnection Requirements for Inverter-Based Generation September 19, 2016 Page 1 of 16 All inverter-based generation connected to Southern Companies transmission system (Point of Interconnection

More information

Transmission Facilities Rating Methodology for Florida

Transmission Facilities Rating Methodology for Florida Document title Transmission Facilities Rating Methodology for Florida Document number EGR-TRMF-00001 Applies to: Transmission Engineering, Transmission System Operations, and Transmission Planning Duke

More information

BC HYDRO REAL TIME OPERATIONS OPERATING ORDER 7T-30A. NORTH COAST INTERCONNECTION: SKEENA BOB QUINN SUBSYSTEM Supersedes OO 7T-30A dated 07 July 2014

BC HYDRO REAL TIME OPERATIONS OPERATING ORDER 7T-30A. NORTH COAST INTERCONNECTION: SKEENA BOB QUINN SUBSYSTEM Supersedes OO 7T-30A dated 07 July 2014 BC HYDRO REAL TIME OPERATIONS OPERATING ORDER 7T-30A NORTH COAST INTERCONNECTION: SKEENA BOB QUINN SUBSYSTEM Supersedes OO 7T-30A dated 07 July 2014 Expiry Year: 2018 APPROVED BY: Original signed by: Paul

More information

MANITOBA HYDRO TRANSMISSION SYSTEM INTERCONNECTION REQUIREMENTS. April 2009 Version 2

MANITOBA HYDRO TRANSMISSION SYSTEM INTERCONNECTION REQUIREMENTS. April 2009 Version 2 MANITOBA HYDRO TRANSMISSION SYSTEM INTERCONNECTION REQUIREMENTS April 2009 Version 2 LEGISLATIVE AUTHORITY Section 15(5) of The Manitoba Hydro Act authorizes Manitoba Hydro to set, coordinate and enforce

More information

Study on the Improvement of the Special Protection Scheme (SPS) in the Korean power system

Study on the Improvement of the Special Protection Scheme (SPS) in the Korean power system Study on the Improvement of the Special Protection Scheme (SPS) in the Korean power system Jeonghoon Shin, Suchul Nam, Seungtae Cha, Jaegul Lee, Taekyun Kim, Junyoen Kim, Taeok Kim, Hwachang Song Abstract--This

More information

Embedded Generation Connection Application Form

Embedded Generation Connection Application Form Embedded Generation Connection Application Form This Application Form provides information required for an initial assessment of the Embedded Generation project. All applicable sections must be completed

More information

Harmonizing the Changing Resource Mix Keeping the Grid Together

Harmonizing the Changing Resource Mix Keeping the Grid Together Harmonizing the Changing Resource Mix Keeping the Grid Together Robert W. Cummings Senior Director of Engineering and Reliability Initiatives i-pcgrid March 30, 2017 NERC-IEEE Memorandum of Understanding

More information

RELAY LOADABILITY CHALLENGES EXPERIENCED IN LONG LINES. Authors: Seunghwa Lee P.E., SynchroGrid, College Station, Texas 77845

RELAY LOADABILITY CHALLENGES EXPERIENCED IN LONG LINES. Authors: Seunghwa Lee P.E., SynchroGrid, College Station, Texas 77845 RELAY LOADABILITY CHALLENGES EXPERIENCED IN LONG LINES Authors: Seunghwa Lee P.E., SynchroGrid, College Station, Texas 77845 Joe Perez P.E., SynchroGrid, College Station, Texas 77802 Presented before the

More information

MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology

MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology MidAmerican Energy Company 100 kv and Above Facility Ratings Methodology For NERC Standard FAC-008 and FAC-009 Issued by: Dan Custer Reviewed by: Tom Mielnik Version 2.7 1 1.0 Scope: This document provides

More information

Transmission Lines and Feeders Protection Pilot wire differential relays (Device 87L) Distance protection

Transmission Lines and Feeders Protection Pilot wire differential relays (Device 87L) Distance protection Transmission Lines and Feeders Protection Pilot wire differential relays (Device 87L) Distance protection 133 1. Pilot wire differential relays (Device 87L) The pilot wire differential relay is a high-speed

More information

GENERAL REQUIREMENTS FOR TRANSMISSION INTERCONNECTION

GENERAL REQUIREMENTS FOR TRANSMISSION INTERCONNECTION GENERAL REQUIREMENTS FOR TRANSMISSION INTERCONNECTION May 31 st, 2017 Rev. 04 Public Utility District No. 2 of Grant County P.O. Box 878, Ephrata, WA 98823 (509) 754-0500 GENERAL REQUIREMENTS FOR INTERCONNECTION

More information

TTC Study for: the PEGS-Ambrosia Lake 230 kv Line and the PEGS-Bluewater 115 kv Line

TTC Study for: the PEGS-Ambrosia Lake 230 kv Line and the PEGS-Bluewater 115 kv Line TTC Study for: the PEGS-Ambrosia Lake 230 kv Line and the PEGS-Bluewater 115 kv Line Vince Leung March 27, 2017 Reviewed by Johnny Nguyen Table of Contents Background 2 Objective 3 Base Case Assumptions

More information

Definition of Bulk Electric System Phase 2

Definition of Bulk Electric System Phase 2 Definition of Bulk Electric System Phase 2 NERC Industry Webinar Peter Heidrich, FRCC, Standard Drafting Team Chair June 26, 2013 Topics Phase 2 - Definition of Bulk Electric System (BES) Project Order

More information

Power Plant and Transmission System Protection Coordination Fundamentals

Power Plant and Transmission System Protection Coordination Fundamentals Power Plant and Transmission System Protection Coordination Fundamentals NERC Protection Coordination Webinar Series June 2, 2010 Jon Gardell Agenda 2 Objective Introduction to Protection Generator and

More information