WIRELESS TRANSMITTERS... 1 PRODUCT SELECTION GUIDES...

Size: px
Start display at page:

Download "WIRELESS TRANSMITTERS... 1 PRODUCT SELECTION GUIDES..."

Transcription

1

2 CONTENTS WIRELESS TRANSMITTERS... 1 PRODUCT SELECTION GUIDES... 9 sensor characteristics... 9 sensor selection guide...10

3 WIRELESS TRANSMITTERS Our wireless transmitters have a proven and field tested coverage in various references around Europe. Effective bidirectional communication with good diagnostics through Modbus communication or analogue signal makes the network reliable and functional. The system includes transmitters for both indoor and outdoor use with repeaters, configuration tool and network functionality monitoring tool. Ideal for monitoring temperature, humidity, air quality, light level, occupancy or pulse counting. Proven coverage Reliable and functional network 868 MHz frequency Modbus PRODUAL 1 CATALOGUE

4 WIRELESS BASE STATION FLTA is a base station for wireless network transmitters. From FLTA, the controls and measurements can be read via Modbus RTU and through the 8 analogue outputs. FLTA base station needs a FLAN antenna. 24 Vac/dc, < 2 VA Range Output Protection class TYPE ART NO. up to 500 m in the line of sight, m in buildings 8 x Vdc, Modbus RTU IP20 For 35 mm DIN rail FLTA base station for wireless sensors FLAN antenna WIRELESS CONFIGURATION TOOL FLSER is a wireless configuration tool for setting the addresses of the sensors and the wireless repeaters. The tool can also be used for testing the communication signal strength. 3,6 V lithium battery Protection class IP20 Materials ABS plastic Dimensions 86 x 86 x 32 mm FLSER configuration tool for wireless devices 7 PRODUAL 2 CATALOGUE

5 WIRELESS REPEATERS FLREP repeaters can be used to extend the range of wireless sensors in difficult environments. It is possible to use up to 8 repeaters for one FLTA base station. 24 Vac/dc, < 0.1 VA / 12 Vac/dc Dimensions 86 x 86 x 32 mm FLREP wireless repeater with internal antenna, for indoor use (IP20) FLREP-U wireless repeater with external antenna, for outdoor use (IP54) M230/ Vac/12 Vdc 4 VA power supply WIRELESS TRANSMITTERS TEFL wireless room temperature sensors are designed for temperature detection of indoor spaces. The communication between the TEFL room units and the FLTA base station is two-way. Commissioning is done by using the wireless FLSER configuration tool. room C, %rh 7 3,6 V lithium battery Range C Accuracy Protection class Material Dimensions ±0,5 C (25 C) IP20 ABS plastic with screws on wall or on junction box (hole distance 60 mm) 86 x 86 x 32 mm TEFL wireless room sensor TEFL-P wireless room sensor with set point adjustment TEFL-RH wireless room sensor with %rh TEFL-RH-P wireless room sensor with %rh and set point setting OPTIONS FL-DI DI option for TEFL FL-S S5 switch option for TEFL FL-N display option for TEFL PRODUAL 3 CATALOGUE

6 WIRELESS TRANSMITTERS TEUFL is a wireless sensor for detecting outdoor temperatures. Communication between the sensors and the FLTA base station is two-way. In addition to temperature information, TEUFL sensor can send also one V signal or one contact (DI) information (TEUFL-DI). Commissioning is done by using the wireless FLSER configuration tool. outdoors C, V 3,6 V lithium battery Input Vdc Range (temperature) C (TEUFL-DI: C) Range (voltage) Vdc Accuracy (temperature) ±0,5 C (25 C) Protection class IP54, cable downwards Material PC plastic Cable gland M16 with screws, external lugs TEUFL wireless outdoor temperature sensor TEUFL wireless outdoor temperature sensor, 24 Vac/dc supply TEUFL-DI wireless outdoor temperature sensor, with a contact (DI) input WIRELESS TRANSMITTERS KLUFL is a wireless transmitter for detecting outdoor temperatures and humidity. The communication between the sensors and the FLTA base station is two-way. Commissioning is done by using the wireless FLSER configuration tool. LUX 11 illumination sensor can be connected to the KLUFL transmitter. outdoors C, %rh, (lx) 7 3,6 V lithium battery Range (humidity) %rh Range (temperature) C Range (illuminance) lx Protection class IP54, cable downwards Material PC plastic Cable gland M16 with screws, external lugs KLUFL wireless outdoor humidity and temperature transmitter LUX illumination and temperature sensor ( 10) LUX illumination and temperature sensor ( 20) PRODUAL 4 CATALOGUE

7 WIRELESS TRANSMITTERS HDHFL transmitters are designed for detecting carbon dioxide concentration and temperature in the room spaces. HDHFL-RH transmitters have also a humidity output. Commissioning is done by using the wireless FLSER configuration tool. room ppm CO₂, C, %rh 24 Vac/dc, < 2 VA Range (CO₂) ppm Range (temperature) C Range (humidity) Time constant Accuracy (CO₂) Accuracy (temperature) Accuracy (humidity) Output Protection class %rh < 1,5 min typ. ±40 ppm ±3 % of value ±0,5 C (25 C) ±2 %rh 3 x Vdc, 2 ma IP20 Ambient temperature C Materials Dimensions TYPE ART NO. with screws on wall or on junction box (hole distance 60 mm) ABS plastic 87 x 86 x 30 mm HDHFL CO₂ and C transmitter with wireless communication HDHFL-N CO₂ and C transmitter with wireless communication and with display HDHFL-RH CO₂, C and %rh transmitter with wireless communication HDHFL-RH-N CO₂, C and % rh transmitter with wireless communication and with display WIRELESS OCCUPANCY SENSOR 7 LAFL is a wireless detector for occupancy monitoring movement. The detector is passive infrared (PIR) which reacts to temperature changes. The communication between the sensors and the FLTA base station is two-way. Commissioning is done by using the wireless FLSER configuration tool. bracket and screws are included to the delivery. 3,6 V lithium battery Range monitoring area 140 ; LAFL-LX: lx Protection class IP40 Ambient temperature C LAFL wireless PIR detector LAFL-LX wireless PIR detector with illumination ( lx) PRODUAL 5 CATALOGUE

8 WIRELESS TRANSMITTERS PAFL is a wireless pulse counter. The counter can be used to measure pulses from electricity consumption meters, gas flow meters and water consumption meters. Commissioning is done by using the wireless FLSER configuration tool. 3,6 V lithium battery or 24 Vac/dc Protection class IP54, cable downwards Material PC plastic Pulse frequency max. 20 Hz Minimum pulse duration 25 ms Ambient temperature C Cable gland M16 with screws, external lugs PAFL wireless pulse counter TOOL FOR MONITORING WIRELESS NETWORK FLSNIF is a tool for monitoring the functionality of the wireless network. By using this tool you may follow one by one the signals between the wireless field equipment and the base station. Monitoring is possible only for signals which are available at the very moment. A PC with installed monitoring software is needed with the tool. The software is delivered with the tool. 7 TYPE ART NO. FLSNIF tool for monitoring the wireless network PRODUAL 6 CATALOGUE

9 SENSOR CHARACTERISTICS Sensor element Pt 100 Pt 1000 Ni 1000 Ni LG AN 10-C 10- KB KP 10 T1 Tol. ±0,3 C/ 0 C EN60751 B ±0,3 C/ 0 C EN60751 B ±0,4 C/ 0 C DIN43760 ±0,4 C/0 C tcr 5000ppm Siemens ±0,3 C/ TAC ±0,/ Johnson ±0,/ ±0,/ Trend / Distech ±0,/ H&W ±0./ Andover ±0./ Carel ±0.5 C/ LM235Z 10 mv/k ±0,4 C/ 0 C Temp. C Ω Ω Ω Ω Ω Ω Ω Ω Ω Ω Ω Ω V Ω , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , PRODUAL 7 CATALOGUE

10 SELECTION GUIDE Product Measured property Type Page C RH CO2 VOC CO Pa bar m/s m 3 /s lux W/m 2 H2O PIR Qty IVL 2 TUNA UV7-LY 18 VS PEL 3~4 PEK / CPS 21 IML 4 KLH 6 KLK 8 KLHJ 7 KLU 7 KLUFL wireless 1) LUX 8~9 MMSP1 10 VPEL 10 VPL 11 HDH 12 HDHFL wireless HDK 13 HDU 14 ILH 15 ILK 16 HML 17 TEAT controller TENA controller TEKV Temp TEV Temp TEP Temp TEPK Temp TEK Temp TEKHA Temp TEKA Temp TEKY Temp TEL Temp TEM Temp TESK Temp TEHR Temp TEHU Temp TEU Temp TES Temp LUK V2 LLK V2 Temp Temp TEUFL wireless TEFL wireless LA 22 LAFL wireless PLT 23 KA SA VVA / VVN 24~25 PAFL wireless 1) Separate light sensor needed. Ω V ma relay Modbus BACnet wireless Output PRODUAL 8 CATALOGUE

WIRELESS BASE STATION WIRELESS CONFIGURATION TOOL WIRELESS REPEATER

WIRELESS BASE STATION WIRELESS CONFIGURATION TOOL WIRELESS REPEATER WIRELESS BASE STATION FLTA is a base station for wireless network transmitters and I/O modules. From FLTA, the controls and measurements can be read via Modbus RTU and through the analogue outputs. Respectively

More information

TEMPERATURE MEASUREMENT...

TEMPERATURE MEASUREMENT... CONTENTS TEMPERATURE MEASUREMENT... 37 heating/cooling water sensors...2 hot domestic water sensors...3 frost guard sensors... strap-on sensors...6 duct sensors...8 combustion gas sensors...11 cable temperature

More information

FROST PROTECTION RELAYS FROST PROTECTION RELAYS HIGH TEMPERATURE ALARM RELAYS. DIN-housing. 11-pole relay housing, IP20.

FROST PROTECTION RELAYS FROST PROTECTION RELAYS HIGH TEMPERATURE ALARM RELAYS. DIN-housing. 11-pole relay housing, IP20. PRODUCT CATALOGUE 2009 FROST PROTECTION RELAYS DIN- Protective devices monitoring heating coils for freezing in the air handling units. 24 Vac, 2 VA range 0-100 C=0-10 V contact 230 Vac, 10 A res. alarm

More information

PRODUAL working with you for efficient building automation projects and services

PRODUAL working with you for efficient building automation projects and services Catalogue 2016 PRODUAL working with you for efficient building automation projects and services We aim to be a one-stop-shop partner for measurement and control for all our customers operating in the evolving

More information

Welcome to the next level of measurement for building automation

Welcome to the next level of measurement for building automation Catalogue 2018 Welcome to the next level of measurement for building automation Our 31-year history has been filled with technical, operational and geographical development and expansion together with

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Wireless Sensor for Humidity / Temperature / CO 2

Wireless Sensor for Humidity / Temperature / CO 2 Series State of the art sensor technology, highest reliability of data transmission and the ease of system installation are the outstanding features of the wireless sensor series. With a modular structure

More information

QPM Series Indoor Air Quality Duct Sensors

QPM Series Indoor Air Quality Duct Sensors Document No. CE1N1962 QPM Series Indoor Air Quality Duct Sensors Description The QPM Series Room Carbon Dioxide (CO 2 ) and Air Quality Duct Sensors are designed for applications where precise, stable

More information

4. Set the FLSER tool switch to the S-RID position. 5. Push the + and - buttons to select the sensor ID (SID) for the transmitter.

4. Set the FLSER tool switch to the S-RID position. 5. Push the + and - buttons to select the sensor ID (SID) for the transmitter. V2.2 (22.08.2014) 1 (8) COISSIONING Selecting the transmitter position The device can be installed in dry surroundings (I20) by screws on the wall surface or on the standard flush mounting box. The recommended

More information

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2 Series State of the art sensor technology, highest reliability of data transmission and the ease of system installation are the outstanding features of the wireless sensor series. Indifferent whether a

More information

Building HVAC components

Building HVAC components Sensors Building HVAC components Belparts is specialized in the development, production and marketing of components for the automation of HVAC systems in buildings. We design field components that exactly

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

AERINOS Profisens - Wireless IoT Platform

AERINOS Profisens - Wireless IoT Platform Introduction AERINOS ProfiSens is a local area wireless IOT platform. It comprises wireless sensor nodes and a 3G Data Gateway. Using ProfiSens, you can deploy anywhere your private IOT network. The battery

More information

Wireless Sensor for Humidity / Temperature / CO 2

Wireless Sensor for Humidity / Temperature / CO 2 State of the art sensor technology, highest reliability of data transmission and the ease of system installation are the outstanding features of the wireless sensor series EE240. Indifferent whether a

More information

Wireless sensor system

Wireless sensor system Wireless sensor system Internet / Ounet PC in internal network GW Internet connection FIGURE 1 structure of wireless sensor network = Base station = Routing wireless sensor = Wireless sensor General description

More information

Analogue temperature controllers

Analogue temperature controllers Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications

More information

MULTIFUNCTION GRAPHICAL UNIT MGU 800

MULTIFUNCTION GRAPHICAL UNIT MGU 800 MULTIFUNCTION GRAPHICAL UNIT MGU 800 For display, recording and evaluation of process instruments signals (level, temperature, pressure, etc.) 3.5" TFT display, multi-language menu Variety of possible

More information

Wireless Sensor for Humidity / Temperature / CO 2

Wireless Sensor for Humidity / Temperature / CO 2 State of the art sensor technology, highest reliability of data transmission and the ease of system installation are the outstanding features of the wireless sensor series EE240. Wireless Sensor for Humidity

More information

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2. EE240 v1.5. preliminary

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2. EE240 v1.5. preliminary preliminary EE40 Series State of the art sensor technology, highest reliability of data transmission and the ease of system installation are the outstanding features of the wireless sensor series EE40.

More information

Mx-RPW Room Control Module (Built-In Occupancy Sensor)

Mx-RPW Room Control Module (Built-In Occupancy Sensor) Wireless Room Controller Application Solar-powered, self-learning room sensor with LCD and smart communication management for measuring room temperature, independent generation of utilization time profiles

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS Zlinx Wireless Modbus I/O-0712ds page 1/5 Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII

More information

OP5U. Pre-programmed, configurable controller for simple applications

OP5U. Pre-programmed, configurable controller for simple applications revision 02 2012 OP5U Pre-programmed, configurable controller for simple applications Optigo is a series of pre-programmed, configurable controllers intended for DIN-mounting that can be set to handle

More information

MODEL AT-10 ANALOG TRANSMITTER

MODEL AT-10 ANALOG TRANSMITTER MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca

More information

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature

More information

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

20 General technical data XI/ON

20 General technical data XI/ON 20 General technical data XI/ON General technical information General technical data XI/ON Potential isolation Ambient temperature Operating temperature Storage temperature Relative humidity Noxious gas

More information

Single point ultrasonic measurement technology, uninterupted by traffic flow and sound reflections

Single point ultrasonic measurement technology, uninterupted by traffic flow and sound reflections Product Data Sheet CODEL TunnelCraft 3 - Air Flow Monitor (S) Air Flow & Direction Low-cost Precision Tunnel Sensors Single point ultrasonic measurement technology, uninterupted by traffic flow and sound

More information

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40 Digital Panel Meters Current and Voltage Indicator/Controller Type LDM40 Multi-input instrument 4-DGT LED 0.1% RDG basic accuracy TRMS AC current and voltage measurements AC/DC current measurements: selectable

More information

Multifunction Intelligent 4-wire Isolated Signal Conditioner

Multifunction Intelligent 4-wire Isolated Signal Conditioner Multifunction Intelligent 4-wire Isolated Signal Conditioner IPAQ-4L is a fully universal and intelligent 4- wire (mains powered) transmitter for temperature measurement and signal conditioning applications.

More information

Wireless Data Logger RTR-500 Series Data Loggers Features and Specs

Wireless Data Logger RTR-500 Series Data Loggers Features and Specs Wireless Data Logger RTR-500 Series Data Loggers Features and Specs Items Temp / Humidity / Illuminance / UV / CO2 / Voltage / 4-20mA / Contact / Pulse Count Data Collection Wireless Communication with

More information

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2

EE240 Series. Wireless Sensor for Humidity / Temperature / CO 2 Series State of the art sensor technology, highest reliability of data transmission and the ease of system installation are the outstanding features of the wireless sensor series. Indifferent whether a

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Power analyzers and Energy Meters Multifunction indicator Type WM12-DIN Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase

More information

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section

More information

P5201 Universal Programmable Transmitters with Galvanic Isolation

P5201 Universal Programmable Transmitters with Galvanic Isolation Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to

More information

Wireless LAN network. Wireless USB network

Wireless LAN network. Wireless USB network Wireless data loggers for humidity and temperature Wireless systems Wireless Data Logger for Humidity and Temperature Probes. HygroClip2 probes for humidity and temperature measurement Wireless frequency:

More information

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless

More information

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QFM21... Duct sensors. Symaro. for relative humidity and temperature 1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10

More information

POTENTIAL APPLICATIONS OF TEKON ELECTRONICS PRODUCTS

POTENTIAL APPLICATIONS OF TEKON ELECTRONICS PRODUCTS 02.V07.2017 TEKON ELECTRONICS Tekon Electronics is an European brand, specialized in the manufacture and development of innovative wireless sensors technology. It is a business unit of Bresimar Automação,

More information

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information.

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information. EN Manufactured by M-Sens 2 Online-Moisture Meter for Solids Product Information Moisture 13.47 % www.onthelevel.com Using M-Sens 2 is specifically designed for continuous moisture measurement of solids.

More information

Energy Management Modular Power Analyzers Type WM2-96

Energy Management Modular Power Analyzers Type WM2-96 ISE, Inc. - 10100 Royalton Rd. - Cleveland, OH 44133 USA Energy Management Modular Power Analyzers Type WM2-96 - Tel: (440) 237-3200 - Fax: (440) 237-1744 - http://instserv.com Class 1 Modular power analyzer

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

N30P DIGITAL PANEL METER

N30P DIGITAL PANEL METER N30P DIGITAL PANEL METER Features: NEW Measurement of single-phase network parameters: voltage, current, active, reactive and apparent power, cosj, tgj, j, frequency, active, reactive and apparent energy,

More information

GS030. Crane Slew-Angle Wireless Measurement Sensor. Features. Application

GS030. Crane Slew-Angle Wireless Measurement Sensor. Features. Application Features Crane Slew-Angle Wireless Measurement Sensor Resolution of 0.1 Accuracy: typical: 0.5 over 360 Range: 0 to 360 Rugged water proof enclosure IP66 Potted electronics for increased water protection

More information

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00 NetBiter I/O Extender 4RO 6RTD 8DIO DAIO User Manual Revision 1.00 IntelliCom Innovation AB Linjegatan 3D SE302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 18 21 99 email info@intellicom.se www

More information

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

C330 / C330X PC-Programmable Universal, 2-wire Transmitter C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and

More information

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

ECB-103 BACnet B-ASC 10-Point Programmable Controllers D a t a s h e e t BACnet B-ASC 10-Point Programmable Controllers Overview The is a microprocessor-based programmable controller designed to control terminal units such as fan coil unit, heat pump unit,

More information

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

Electronic Thermostat TE-1 Version according to EN

Electronic Thermostat TE-1 Version according to EN JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 e-mail: mail@jumo.net Internet: www.jumo.net JUMO

More information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5. Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A. 3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2 (Code 7 71 071 to 7 71 083) INSTRUCTION MANUAL ( M 981 200 / 00 A ) (c) CIRCUTOR S.A. ----- MKT- MKT2 - ELECTRONIC METERS -------- M-981 200 --- Page Nº 2 3

More information

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs European Electronic Controls Catalogue Catalogue Section A Product Bulletin TS-9100 Issue Date 09 2000 TS-9100 Electronic Sensors and Transducers I ntroduction The TS-9100 series of electronic temperature

More information

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement ULTRASONlC FlOWMETER SAMPLE BOOK TYPE:LRF-3300S Concentrating on Flow Measurement Introduction LRF-3300S is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp

More information

RSMFX-2R MULTIFUNCTIONAL

RSMFX-2R MULTIFUNCTIONAL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out. Technical Data Sheet Theta 60R 60 R 60 R Fig. Theta R, channel version, in housing S7 clipped on to a top - hat rail. Fig. Theta R, channel version, in housing S7 hole mounting brackets pulled out. Theta

More information

Universal Voltage Cabled Photoelectric E3JK

Universal Voltage Cabled Photoelectric E3JK Universal Voltage Cabled Photoelectric Small Cable Sensor with Complementary Outputs Universal AC/DC supply voltage Relay or NPN/PNP transistor output, light-on or dark-on operation Polarized retroreflective

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J Electrical temperature measurement Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J WIKA data sheet TE 91.01 for further approvals

More information

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions Wireless Temperature and Humidity Overview and Indentification The Wireless Temperature and Humidity measures the room temperature and Relative Humidity and transmits the data at 418MHz or 433MHz RF to

More information

Wireless LAN network. Wireless USB network

Wireless LAN network. Wireless USB network Wireless data loggers for humidity and temperature Wireless systems Wireless Data Logger for Humidity and Temperature Probes. HygroClip 2 Probes for humidity and temperature measurement Wireless frequency:

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Up to Category 2, EN 954-1 Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel

More information

Wireless systems.

Wireless systems. Wireless data loggers for humidity and temperature Wireless systems Wireless Data Logger for Humidity and Temperature Probes. HygroClip 2 Probes for humidity and temperature measurement Wireless frequency:

More information

INFOCAL 8 Energy calculator

INFOCAL 8 Energy calculator Data sheet INFOCAL 8 Energy calculator Description/Application MID examination certificate no.: DE-10-MI004-PTB008 The INFOCAL 8 is an energy calculator e.g. for combination with SONO 1500 CT especially

More information

SonoMeter 31 Energy Meters

SonoMeter 31 Energy Meters SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement Modbus ASCII /RTU Compatible Wide Operating Temperature Active Repeater Functionality 10 to 48 VDC & 24 VAC Input Power Zlinx Wireless Modbus I/O - flexible enough

More information

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output www.cometsystem.com Instruction Manual T5140 T5141 T5145 Programmable transmitter of CO2 concentration with 4-20 ma output T5240 T5241 T5245 Programmable transmitter of CO2 concentration with 0-10 V output

More information

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming Energy Management Type WM14 DI version Protection degree (front): IP40 2 digital outputs 16 freely configurable alarms with OR/AD logic linkable with up to 2 digital outputs RS422/485 serial output (MODBUS-RTU),

More information

Loud electronic horn High life duration up to 5,000 hrs TECHNICAL SPECIFICATIONS: PC, PC/ABS-Blend, grey Fixing:

Loud electronic horn High life duration up to 5,000 hrs TECHNICAL SPECIFICATIONS: PC, PC/ABS-Blend, grey Fixing: 584 Horn Loud electronic horn High life duration up to 5,000 hrs Integrated mounting bracket Dimensions (D x W x H): 91.5 mm x 82.5 mm x 198 mm PC, PC/ABS-Blend, grey Bracket mounting Installation position:

More information

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S. EN SolidFlow.0 Product Information Solid mass flow measurement SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.A Group Use SolidFlow.0 has been specially developed for measuring

More information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03

More information

CDG. Carbon Dioxide - User Manual Gas Detector. 1 Intended Use. 2 Functional Description. 3 Installation. 4 Electrical Connection.

CDG. Carbon Dioxide - User Manual Gas Detector. 1 Intended Use. 2 Functional Description. 3 Installation. 4 Electrical Connection. Carbon Dioxide - User Manual 1 Intended Use 2 Functional Description 2.1 Control Mode 2.2 Sensor 3 Installation 3.1 Mounting instructions 3.2 Installation 4 Electrical Connection 4.1 Instruction 5 Commissioning

More information

CONTROL Room. Room product for Swegon s WISE system for demand-controlled ventilation. Quick facts Room control against temperature, CO 2

CONTROL Room. Room product for Swegon s WISE system for demand-controlled ventilation. Quick facts Room control against temperature, CO 2 Room product for Swegon s WISE system for demand-controlled ventilation Quick facts Room control against temperature, CO 2, content, etc. Static pressure and flow measurement Position-independent Shut-off-capable

More information

made in finland product catalogue

made in finland product catalogue made in finland product catalogue EN 2 HK instruments references 3 High-quality measuring Cooperation with CTS Teknik in Denmark devices for clean indoor air HK Instruments is a family-owned Finnish company

More information

IJINUS. HF communication /////

IJINUS. HF communication ///// Level measuring range from 3 to 10m Integrated conversion tables(flow rate, volume) Wireless setting with Rfid technology Memory : up to 500 000 measures Sealing : IP68 Replaceable lithium battery powered

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

User Manual. tsense VAV Disp. CO 2 -, temperature- and relative humidity transmitter

User Manual. tsense VAV Disp. CO 2 -, temperature- and relative humidity transmitter User Manual tsense VAV Disp CO 2 -, temperature- and relative humidity transmitter General tsense VAV for wall mounting measures indoor air carbon dioxide concentration, temperature and relative humidity

More information

Online data sheet WT260-R260 W260 PRODUCT PORTFOLIO

Online data sheet WT260-R260 W260 PRODUCT PORTFOLIO Online data sheet WT60-R60 W60 A B C D E F Illustration may differ Ordering information Type Part no. WT60-R60 60097 Other models and accessories www.sick.com/w60 H I J K L M N O P Q R S T Detailed technical

More information

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ). ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,

More information

EasyclickPro. Wireless Control Systems Making light work

EasyclickPro. Wireless Control Systems Making light work EasyclickPro Wireless Control Systems Making light work EasyclickPro EasyclickPro RF system The new Easyclick generation Honeywell Easyclick wireless and battery-less solutions for lighting, shutter and

More information

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use Wireless New Products... New Solutions The range of telemetry modules provide remote monitoring and control by radio or twisted-pair wire, over short or long distances. Transducer signals connected at

More information

WIRELESS MODBUS GATEWAY WGW410

WIRELESS MODBUS GATEWAY WGW410 WIRELESS MODBUS GATEWAY WGW410 The Tekon Wireless Modbus Gateway WGW410 is specifically designed to meet the most rigorous requirements of operation in the industrial process environments. Due to their

More information

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/. Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

EY-EM 527: Remote I/O module, ecolink527

EY-EM 527: Remote I/O module, ecolink527 Product data sheet 94.078 EY-EM 527: Remote I/O module, ecolink527 How energy efficiency is improved Regulation, control, monitoring and optimisation of operational systems, e.g. room automation or HVAC

More information

Room air quality sensors

Room air quality sensors 1 961 QPA10 / QPA20 1961P01 1961P02 QPA20 D Room air quality sensors QPA10.. QPA20.. Maintenance-free sensing element (depending on type) based on optical infrared absorption measurement (NDIR 1) ) Or

More information

SENSORS. Seamlessly Integrated SENSORS

SENSORS. Seamlessly Integrated SENSORS 20 Seamlessly Integrated Innovative technology to work seamlessly with all leading control companies ensuring performance. Reliable and accurate readings providing energy and cost-effi cient control backed

More information

ENGLISH S-CO2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS CO 2. TF5701_B_v1_web

ENGLISH S-CO2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS CO 2. TF5701_B_v1_web S-CO2 CO 2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS ENGLISH TF5701_B_v1_web 1 DESCRIPTION This module measures carbon dioxide (CO 2 ) in the range of 0 to 2 000 ppm and is equipped with

More information

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080 Overview The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1-path or -path) FUS80 (-path) FUE80 (-path) The transmitter FUS080 is always

More information

Z500. High-Precision Sensor that Measures and Displays an Object's Profile. Profile Measuring System

Z500. High-Precision Sensor that Measures and Displays an Object's Profile. Profile Measuring System Profile Measuring System High-Precision Sensor that Measures and Displays an Object's Profile. Features OMRON's original line beam method provides a complete solution to profile measurement problems. Conventional

More information

Conductivity Analyzer

Conductivity Analyzer Data Sheet Conductivity Analyzer Comprehensive range of field-proven conductivity cells satisfies broad range of applications. Comprehensive diagnostics facility with in-built software protection ensures

More information

L DN 2810 FL DE 3925 L DN 2810 FL PIR DE 3925 L DN 5630 FL DE 3925 L DN 5630 FL PIR DE 3925 L DN 9850 FL DE 3925 L DN 9850 FL PIR DE 3925

L DN 2810 FL DE 3925 L DN 2810 FL PIR DE 3925 L DN 5630 FL DE 3925 L DN 5630 FL PIR DE 3925 L DN 9850 FL DE 3925 L DN 9850 FL PIR DE 3925 D Operating instructions Slim LED Light L DN 2810 FL L DN 2810 FL PIR L DN 5630 FL L DN 5630 FL PIR L DN 9850 FL L DN 9850 FL PIR Attention: efore assembly of the light, please carefully read the operating

More information

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier Ultraminiature Photoelectric Sensors with Self-contained Amplifier HPJSeries HPJ Fingertip-size, Provided with a various slit attachments. (six types) Fingertip-size 22 x 11 x 8mm (thru scan model) 30

More information

Digital indicator for panel mounting With multi-function input Model DI25

Digital indicator for panel mounting With multi-function input Model DI25 Accessories Digital indicator for panel mounting With multi-function input Model DI25 WIKA data sheet AC 80.02 Applications Plant construction Machine tools Plastics technology and processing Ventilation

More information

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions ELECTRONIC FAN SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5

More information

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH D-71145 Bondorf. Germany D-07987 Mohlsdorf-Teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0. Fax +49 (0)7457-3758 Tel. +49(0)3661-62704-0.

More information

Trip amplifier, 1 channel

Trip amplifier, 1 channel Trip amplifier, channel Features I II III + + P I out I U out 4 Relay overrange Relay overrange Relay overrange ç 4...0 ma IM4-4-SRi: è 0...0 ma IV + + + > 50 kw 5 6 7 8 9»8 V < 5 ma 50 W Pwr GN/RD 4 5

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C),

More information