Environmental Management System

Size: px
Start display at page:

Download "Environmental Management System"

Transcription

1 Printed Date: PORT KEMBLA COAL TERMINAL HSEC Noise Management Plan Printed By: Management Plan MP.HS.387 Status:Approved Version:7.0 Doc ID:387 Page 1 of 38 Environmental Management System Noise Management Plan and Monitoring Program This is a Controlled Document in SharePoint Controlled Documents Library UNCONTROLLED IF VIEWED OUTSIDE OF SHAREPOINT; valid for 48 Hours from time printed. AUTHORISED BY: Alex Chalk, Risk Manager- Date Authorised: 11/11/2011

2 Printed Date: PORT KEMBLA COAL TERMINAL HSEC Noise Management Plan Contents Printed By: Management Plan MP.HS.387 Status:Approved Version:7.0 Doc ID:387 Page 2 of INTRODUCTION Purpose Background Scope 3 2. OBJECTIVES REFERENCES RESPONSIBILITIES LEGISLATIVE AND OTHER REQUIREMENTS Legislative Requirements Environmental Protection Licence Requirements Department of Planning and Infrastructure: Approval Conditions Policies and Standards 6 6. MANAGEMENT STRATEGIES Operational Activities and Potential Noise Issues Environmental Aspects and Impacts Noise Management and Mitigation Management Strategy and Effectiveness 9 7. EVENT MANAGEMENT Emergency Response and Investigation 9 8. MONITORING General Noise Monitoring Program Noise Monitoring Program Implementation REPORTING AND REVIEW Monitoring Data Auditing Corrective Actions Review COMPLAINTS RECORDING AND REPORTING DOCUMENTATIONS AND RECORDS Attachment A... 1 This is a Controlled Document in SharePoint Controlled Documents Library UNCONTROLLED IF VIEWED OUTSIDE OF SHAREPOINT; valid for 48 Hours from time printed. AUTHORISED BY: Alex Chalk, Risk Manager- Date Authorised: 11/11/2011

3 Printed Date: PORT KEMBLA COAL TERMINAL HSEC Noise Management Plan 1. INTRODUCTION 1.1 Purpose Printed By: Management Plan MP.HS.387 Status:Approved Version:7.0 Doc ID:387 Page 3 of 38 The purpose of this noise management plan (NMP) is to set out the requirements for the management and monitoring of noise associated with PKCT s site operations. This plan has been prepared in accordance with the Department of Planning and Infrastructure (DPI) s approval conditions (refer Section 5.3 herein) which includes a requirement for PKCT prepare and implement a noise monitoring program. 1.2 Background Port Kembla Coal Terminal (PKCT) provides a coal and bulk products receival, storage and shipping loading service to its customers. PKCT is located on north side of the inner harbour and operates premises leased from the Port Kembla Port Corporation. PKCT has been operating since August 1990 and has an office of Environment and Heritage Environmental Protection Licence (EPL) to operate. Noise is an environmental aspect with the potential to impact on the amenity of the community. This aspect is managed through PKCT s environmental management system which has quality certification to ISO In June 2009, the Department of Planning and Infrastructure issues PKCT approval no. 08_0009 which set new approval conditions for PKCT s operations including some pertaining to noise. This has required development of a noise monitoring program. Program has been developed in consultation with the Office of Environment and Heritage and is incorporated in this management plan (NMP). 1.3 Scope This NMP applies to activities and aspects of PKCT operations with the potential to result in noise impacting on amenity on site and on the community and stakeholders external to PKCT s premises. This NMP does not cover health aspects associated with noise and hearing loss. PKCT has health and hygiene management processes and programs covered elsewhere within its management system to cover this aspect. This is a Controlled Document in SharePoint Controlled Documents Library UNCONTROLLED IF VIEWED OUTSIDE OF SHAREPOINT; valid for 48 Hours from time printed. AUTHORISED BY: Alex Chalk, Risk Manager- Date Authorised: 11/11/2011

4 Printed Date: PORT KEMBLA COAL TERMINAL HSEC Noise Management Plan Printed By: Management Plan MP.HS.387 Status:Approved Version:7.0 Doc ID:387 Page 4 of OBJECTIVES The objectives of this Noise Management Plan are to:- Comply with regulatory requirements set out in EPL 1625 and the DPI s approval conditions (refer Section 3 & 5.3) Define PKCT s environment management system and the associated measures to control noise compatible with efficient PKCT operations Define PKCT s noise monitoring program and the process for assessing noise data against standards Outline process for developing preventative, corrective and improvement actions to reduce noise Outline the process for investigating noise complaints and reviews. 3. REFERENCES PKCT OEH Environment Protection Licence (EPL) no Department of Planning and Infrastructure Approval 08_0009 PKCT Policies- Sustainable Development; Environment; Quality BHPB Environment Standard (STA.020) PKCT Noise Monitoring Program (07355-C) Version C: prepared by consultant, Wilkinson Murray P/L- refer Attachment A herein. 4. RESPONSIBILITIES Risk Manager is responsible to the General Manager for the coordination and implementation of this plan. Risk Manager is responsible for the process for the management of Customer and Stakeholder complaints and enquires (including customer complaints). Operations Manager is responsible for the control of operations to ensure noise is minimised and is within acceptable limits. Engineering Manager is responsible for maintenance, reliability and effective operation of site equipment ensuring the associated noise is minimised and is within acceptable limits. This is a Controlled Document in SharePoint Controlled Documents Library UNCONTROLLED IF VIEWED OUTSIDE OF SHAREPOINT; valid for 48 Hours from time printed. AUTHORISED BY: Alex Chalk, Risk Manager- Date Authorised: 11/11/2011

5 Printed Date: PORT KEMBLA COAL TERMINAL HSEC Noise Management Plan Printed By: Management Plan MP.HS.387 Status:Approved Version:7.0 Doc ID:387 Page 5 of LEGISLATIVE AND OTHER REQUIREMENTS 5.1 Legislative Requirements Legislation relating to the management of noise includes: Protection of the Environment Operations Act 1997 (POEO Act) Protection of the Environment Operations (General) regulation 1998; and Protection of the Environment Operations (Noise) Regulation Environmental Protection Licence Requirements EPL No applies to PKCT s site operations and contains conditions pertaining to noise (nb Section 3 herein) 5.3 Department of Planning and Infrastructure: Approval Conditions On the 12 th June 2009, the Minister for Planning approved a Project Application (08_0009) submitted by Port Kembla Coal Terminal (PKCT) to change receival arrangements. The project approved by the minister was defined as the development described in the environmental assessment. The project was approved with conditions including a requirement for PKCT to prepare and implement a Noise Monitoring Program in consultation with Office of Environment and Heritage. The Conditions of Consent specify the requirements with which PKCT must comply during its operations as follows. This is a Controlled Document in SharePoint Controlled Documents Library UNCONTROLLED IF VIEWED OUTSIDE OF SHAREPOINT; valid for 48 Hours from time printed. AUTHORISED BY: Alex Chalk, Risk Manager- Date Authorised: 11/11/2011

6 Printed Date: PORT KEMBLA COAL TERMINAL HSEC Noise Management Plan Printed By: Management Plan MP.HS.387 Status:Approved Version:7.0 Doc ID:387 Page 6 of Policies and Standards A management system in place which operates in accordance with the PKCT s Sustainable Development Policy and Environment (refer ) This noise management plan has been developed in accordance with these policies. The system is certified to ISO and includes documented procedures, environmental aspects assessed and registered with processes for their control and continual improvement. The system is subject to audit and review including biannual surveillance visits by PKCT s external certifier. This is a Controlled Document in SharePoint Controlled Documents Library UNCONTROLLED IF VIEWED OUTSIDE OF SHAREPOINT; valid for 48 Hours from time printed. AUTHORISED BY: Alex Chalk, Risk Manager- Date Authorised: 11/11/2011

7 Printed Date: PORT KEMBLA COAL TERMINAL HSEC Noise Management Plan 6. MANAGEMENT STRATEGIES Printed By: Management Plan MP.HS.387 Status:Approved Version:7.0 Doc ID:387 Page 7 of Operational Activities and Potential Noise Issues Environmental impact of noise associated with PKCT s operation was taken into account in the Environmental Impact Assessment which preceded approval and construction of the coal terminal. From time to time, further assessments have been undertaken for OH&S and Environmental reasons. Noise has not been a significant environmental issue in the operation of PKCT. Excessive noise is more likely to be incident based e.g. roller requiring maintenance rather than the day to day noise levels being generated by PKCT. There are a number of on site noise sources, however, which generate noise above 85dB. Key noise sources are as follows:- Operating conveyors particularly around the head end of conveyors Ship loader boom hoist area Transfer Station 6 Rail Receival- trains/ wagon doors Portable equipment such as angle grinders Truck compression braking, tail gates, hoists 6.2 Environmental Aspects and Impacts Potential for noise impacting on site and on the community is recognised as an environmental aspect and included in PKCT s Environmental Aspects and Impacts Register RG.HSEC Historically, noise has not been the subject of community complaints. Rather, it has been a health and hygiene issue in terms of exposure to site personnel when working in proximity to operating equipment. There are a number of locations which have been identified requiring mandatory hearing protection. Many of these locations are within enclosed structures so that the associated noise off site is diminished. Residential areas are in close proximity to the north of PKCT s site, 800 metres to the north of site entrance at Port Kembla Road. This area has realised significant development in recent years resulting in increasing resident density and a changing demographic. PKCT strategic reviews have concluded that the community are likely to have less tolerance for the neighbouring industrial precinct on aspects impacting on their amenity. This is a Controlled Document in SharePoint Controlled Documents Library UNCONTROLLED IF VIEWED OUTSIDE OF SHAREPOINT; valid for 48 Hours from time printed. AUTHORISED BY: Alex Chalk, Risk Manager- Date Authorised: 11/11/2011

8 Printed Date: PORT KEMBLA COAL TERMINAL HSEC Noise Management Plan Printed By: Management Plan MP.HS.387 Status:Approved Version:7.0 Doc ID:387 Page 8 of Noise Management and Mitigation Noise Considerations The impact and nuisance level of noise generated from PKCT is not only a function of the noise level transmitted by a noise source but also influenced by back ground noise levels and other noise sources transmitting at the same time (e.g. likely to be a greater concern at night time). Higher than normal noise level may also occur if an equipment component is faulty and requires maintenance. When carrying out plant and equipment inspections and maintenance, consideration needs to be given to plant and equipment emitting unusually high noise levels and, if detected, the necessary repairs shall be carried out as appropriate. Impact of noise nuisance on community is a consideration when planning work. In particular, certain types of maintenance and construction work e.g. jack hammering, pile driving, demolition may result in unacceptable noise levels at night. Work needs to be programmed to allow for this or effective sound insulation barriers or other mitigation measure need to be provided. Noise impacts (operating and during construction) need to be taken into account when considering plant modifications, upgrades and new equipment. Environmental Management System PKCT EMS system is documented, controlled and supported by management plans and procedures with processes covering:- Environmental aspects and impacts Planning and objectives Legal and other requirements Training and competency Emergency Management and Investigation Monitoring, Auditing and Review Noise Controls Equipment and processes established on site to control noise include the following:- Rail receival enclosed within a shed Road and Rail Receival conveyors initially underground then enclosed within conveyor galleries and transfer stations This is a Controlled Document in SharePoint Controlled Documents Library UNCONTROLLED IF VIEWED OUTSIDE OF SHAREPOINT; valid for 48 Hours from time printed. AUTHORISED BY: Alex Chalk, Risk Manager- Date Authorised: 11/11/2011

9 Printed Date: PORT KEMBLA COAL TERMINAL HSEC Noise Management Plan Printed By: Management Plan MP.HS.387 Status:Approved Version:7.0 Doc ID:387 Page 9 of 38 Truck driver rules and the Drivers Code of Code covering requirements relating to driver practices, in particular compression braking and speed control Job planning and risk assessment processes are in place which gives consideration to health, safety, environmental and community impacts ensuring aspects such as noise are identified, considered and suitable controls are put in place. 6.4 Management Strategy and Effectiveness Improvement strategies are developed through PKCT s Business Planning process. External noise consultant expertise is used where appropriate to identify improvement opportunities. Networking is also undertaken with other coal terminals and within the industry to:- Ensure PKCT has up to date knowledge of best practice noise management methodologies when developing improvement strategies. Benchmark noise levels with other bulk terminals to check its performance Site noise surveys and mapping is undertaken from time to time to assess on site noise sources and external impacts associated with PKCT s operations. 7. EVENT MANAGEMENT 7.1 Emergency Response and Investigation PKCT has emergency response processes in place in case of significant noise events which may be observed internally through site observations or through an external community or stakeholder complaint. These processes provide for action to be taken to mitigate impacts. Events are investigated to develop corrective actions. This is a Controlled Document in SharePoint Controlled Documents Library UNCONTROLLED IF VIEWED OUTSIDE OF SHAREPOINT; valid for 48 Hours from time printed. AUTHORISED BY: Alex Chalk, Risk Manager- Date Authorised: 11/11/2011

10 Printed Date: PORT KEMBLA COAL TERMINAL HSEC Noise Management Plan Printed By: Management Plan MP.HS.387 Status:Approved Version:7.0 Doc ID:387 Page 10 of MONITORING 8.1 General PKCT uses expert consultants as necessary to assist in the management of noise associated with its operations. Noise related work associated the DPI Approval 08_0009 was undertaken by Wilkinson Murray P/L as follows:- Noise assessment as part of PKCT s submission of Project (MP 08_0009) to the Department of Planning and Infrastructure. Upon receipt of Approval 08_0009, a noise monitoring program was developed as required by DPI approval conditions referenced in Section 5.3 herein. Compliance monitoring surveys carried out to assess noise against noise criteria. 8.2 Noise Monitoring Program PKCT s noise monitoring program is provided in Wilkinson Murray s report PKCT Noise Monitoring Program (07355-C) Version C (referenced in Section 3 herein) and attached as Attachment A. 8.3 Noise Monitoring Program Implementation Program shall be implemented in accordance with section 8.2 and as specified herein. PKCT shall ensure suitably qualified external service providers and/or consultants are engaged to carry out the work. Service providers shall ensure that the equipments/ instruments used are suitably calibrated in accordance with the relevant Australian Standards and manufacturer s specification. To the extent practical, consideration shall be given to the nature of operations forecast when scheduling a noise survey to ensure it is representative of PKCT operations with road, rail and ship loading operations taking place. This is a Controlled Document in SharePoint Controlled Documents Library UNCONTROLLED IF VIEWED OUTSIDE OF SHAREPOINT; valid for 48 Hours from time printed. AUTHORISED BY: Alex Chalk, Risk Manager- Date Authorised: 11/11/2011

11 Printed Date: PORT KEMBLA COAL TERMINAL HSEC Noise Management Plan Printed By: Management Plan MP.HS.387 Status:Approved Version:7.0 Doc ID:387 Page 11 of REPORTING AND REVIEW 9.1 Monitoring Data Data shall be recorded, assessed and reported as outlined herein and in accordance with DPI approval conditions. Reporting of noise monitoring results and exceedances shall include:- PKCT internal reporting (e.g. bi annual reports) Reports to Regulatory Agencies (e.g. EPL annual returns, Annual Environment Management Report); and Community Reports (e.g. PKCT annual Sustainability Reports; reports to community groups) 9.2 Auditing PKCT has a number of audit processes to check noise being generated on site. These processes include the following:- Site level Critical Task Observations i.e. mini audit Internal Audit Program (including ISO 14001) ISO external surveillance audit- 6 monthly covering different aspects of PKCT s EMS BHPB HSEC self assessments and external audits DPI Approvals Implementation: triennial external audit Results of audits and associated corrective actions are tracked by senior management through quarterly Business Management System review meetings. 9.3 Corrective Actions In the event that the noise monitoring program, site assessment or a local community member identifies an exceedance of the noise criteria stipulated in the EPL and DPI approval, the Risk Manager will investigate the noise source and appropriate corrective action will be undertaken. In the event that the investigation determines that noise from PKCT operations is likely to be responsible for an exceedance of the noise criteria at nearby residences, the Director-General of DOP will be notified. Monitoring results will be published in PKCT s Annual Environmental Management Report. This is a Controlled Document in SharePoint Controlled Documents Library UNCONTROLLED IF VIEWED OUTSIDE OF SHAREPOINT; valid for 48 Hours from time printed. AUTHORISED BY: Alex Chalk, Risk Manager- Date Authorised: 11/11/2011

12 Printed Date: PORT KEMBLA COAL TERMINAL HSEC Noise Management Plan 9.4 Review Printed By: Management Plan MP.HS.387 Status:Approved Version:7.0 Doc ID:387 Page 12 of 38 The noise monitoring program shall be reviewed in consultation with OEH and DPI at least every three years. The review shall consider monitoring results, changes in environmental expectations, technology and operational procedures. If no exceedance of the criteria occurs for 6 years, noise monitoring will not be required to continue. 10. COMPLAINTS RECORDING AND REPORTING PKCT has a 24 hour, 7 day free call community hotline number ( ) or e mail communitylinks@pkct.com.au. which is advertised on PKCT website i.e. This provides a mechanism by which complaints and general enquiries regarding environmental or community issues associated with operational activities can be directed. PKCT has a Community and Stakeholder Complaints Management process in place which ensures complaints are recorded, registered and investigated. Where appropriate, corrective actions are developed and implemented. If the noise impact assessment criteria is exceeded, all aspects of operations will be reviewed to identify improvements. If concerns over noise at a particular location are identified via a complaint or by other means, specific monitoring may be undertaken to quantify the potential noise impact. 11. DOCUMENTATIONS AND RECORDS This management plan is a controlled document stored in PKCT s Sharepoint Controlled Documents library. Monitoring results, reports and associated documentation shall be retained, held secure and accessible. N This is a Controlled Document in SharePoint Controlled Documents Library UNCONTROLLED IF VIEWED OUTSIDE OF SHAREPOINT; valid for 48 Hours from time printed. AUTHORISED BY: Alex Chalk, Risk Manager- Date Authorised: 11/11/2011

13 12. Attachment A Page 1

14 Page 2

15 Page 3 TABLE OF CONTENTS Page 1 Introduction 5 2 Site Description 6 3 Legislative & other requirements Legislative Requirements Conditions of Approval 8 4 Noise monitoring Responsibilities Monitoring Standards Monitoring Locations Monitoring Protocol Summary of Attended Monitoring 16 5 Reporting 17 6 Review 6.1 Corrective Action Complaints Review 20 APPENDIX A Glossary APPENDIX B BarnOwl Directional Noise Monitoring System

16 Page 4 DOCUMENT CONTROL Noise Monitoring Program PKCT Approval: Authorising Officer Title Signature Date Revision Status: Revision Date Prepared By Checked By Comments A John Wassermann Adam Bioletti B John Wassermann Adam Bioletti C Sam Demasi John Wassermann For OEH Comment Note All materials specified by Wilkinson Murray Pty Limited have been selected solely on the basis of acoustic performance. Any other properties of these materials, such as fire rating, chemical properties etc. should be checked with the suppliers or other specialised bodies for fitness for a given purpose. The information contained in this document produced by Wilkinson Murray is solely for the use of the client identified on the front page of this report. Our client becomes the owner of this document upon full payment of our Tax Invoice for its provision. This document must not be used for any purposes other than those of the document s owner. Wilkinson Murray undertakes no duty to or accepts any responsibility to any third party who may rely upon this document. Quality Assurance We are committed to and have implemented AS/NZS ISO 9001:2008 Quality Management Systems Requirements. This management system has been externally certified and Licence No. QEC has been issued. AAAC This firm is a member firm of the Association of Australian Acoustical Consultants and the work here reported has been carried out in accordance with the terms of that membership.

17 Page 5 1. Introduction This Noise Monitoring Program (NMP) has been prepared to address the requirements for noise monitoring as outlined in the Department of Planning s (DoP) Conditions of Approval (CoA) (08/0009), dated 12 June Please note that the Department of Planning is now known as Department of Planning and Infrastructure (DPI). The objective of this program is to: have a robust noise monitoring procedure that will identify noise levels from Port Kembla Coal Terminal (PKCT) and clearly identify compliance (or otherwise) with the Impact Assessment Criteria; and provide monitoring information and advice to ensure that noise emissions from the site are appropriately managed and where necessary reduced. This protocol is not intended to be a static document, it will be maintained and updated as further information or suggestions become available.

18 Page 6 2. Site Description The Port Kembla Coal Terminal (PKCT) is a major coal intermodal facility that receives coal by road and rail for loading onto ships for export. Currently PKCT site operations are permitted 24 hours per day, 7 days per week. The site operations typically include: Delivery of material by road and rail to receival hoppers; Transfer of received coal via conveyor to stackers to be stockpiled prior to arrival of ship; Transfer of products received to Bulk Product Berth to stockpile via front end loader; Movement of stockpiled coal to the ship loader using bucket wheel reclaimers and conveyors; Loading of coal to ship using the ship loader at Berth 102; and Loading of product received at Bulk Product Berth to ship via ship loader at Berth 101. Figure 2-1 shows the site plan of the PKCT site.

19 Page 7 Figure 2-1 Site Plan for PKCT

20 Page 8 3. Legislative & other requirements 3.1 Legislative Requirements Legislation relating to the management of noise includes: Protection of the Environment Operations Act 1997 (POEO Act); Protection of the Environment Operations (General) Regulation 1998; and Protection of the Environment Operations (Noise Control) Regulation Conditions of Approval The CoA specifies the requirements with which PKCT must comply during its operations, with respect to noise, this includes the following: NOISE Impact Assessment Criteria 1. The Proponent shall ensure that the noise generated by the project at any privately-owned residence does not exceed the criteria specified in Table 1 for the location nearest to that residence. Table 1 Noise impact assessment criteria db(a) L Aeq,(15min) Notes: Location Cnr Swan & Kembla Streets Cnr Swan & Corrimal Streets Cnr Keira & Fox Streets Time Period Noise Criteria L Aeq,(15min) (dba) Day 51 Evening 50 Night 49 Day 51 Evening 50 Night 49 Day 55 Evening 49 Night 45 a) To determine compliance with the L Aeq,(15min) noise level limits in the above table, noise from the project is to be measured at the most affected point within the residential boundary. Where it can be demonstrated that direct measurement of noise from the project is impractical, the DECC may accept alternative means of determining compliance (see Chapter 11 of the NSW Industrial Noise Policy). The modification factors in Section 4 of the NSW Industrial Noise Policy shall also be applied to the measured nois levels were applicable. b) The noise emission limits identified in the above table apply under meteorological conditions of: - wind speecs of up to 3m/s at 10m above ground level; or - temperature inversion conditions of up to 3ºC/100m, plus a 2m/s source-to-receiver component drainage flow wind at 10m above ground level for those receivers where applicable in accordance with the NSW Industrial Noise Policy.

21 Page 9 However, if the Proponent has a written negotiated noise agreement with any landowner of the land listed in Table 1, and a copy of this agreement has been forward to the Department and DECC, then the Proponent may exceed the noise limits in Table 1 in accordance with the negotiated noise agreement. Noise Monitoring Program 2. The Proponent shall prepare and implement a Noise Monitoring Program for the project to the satisfaction of the Director-General. This program must: a) be developed in consultation with DECC. b) be submitted to the Director-General for approval within 6 months from the date of this approval, or as otherwise agreed by the Director-General; and c) include a: - combination of attended and unattended noise monitoring measures; - noise monitoring protocol for evaluating compliance with the noise impact assessment criteria in this approval; and - reasonable and feasible best practice noise mitigation measures to ensure project specific noise criteria are met. Note that the Department of Environment and Climate Change (DECC) became the Department of Environment, Climate Change and Water (DECCW), however is now known as the Office of Environment and Herritage (OEH).

22 Page Noise monitoring 4.1 Responsibilities Table 4-1 presents the personnel at PKCT who are responsible for noise monitoring. Table 4-1 Responsibilities for Noise Monitoring Procedure Responsibility Ensuring environmental noise monitoring is carried out Confirming typical operations during noise monitoring Record noise monitoring results Where the levels exceed the targets, implement further controls Risk Manager Operations Manager Risk Manager Operations Manager 4.2 Monitoring Standards Noise monitoring at PKCT will be undertaken in general accordance with all relevant Australian Standards, Legislation and OEH approved methods for monitoring. The relevant documents are listed below: AS : Acoustics Measurement and Description of Environmental Noise; Part 1: General procedures AS IEC Electoacoustics Sound Level Meters. Environmental Noise Control Manual (EPA, 1994); NSW Industrial Noise Policy (EPA, 2000); and NSW Road Noise Policy (DECCW, 2011). 4.3 Monitoring Locations Noise monitoring during operations will be undertaken at the locations specified in Table 4-2 representing the catchments areas shown in Figure 4-1. Specific monitoring locations are shown in Figures 4-2 to 4-4. These monitoring locations have been selected as they are representative of potentially impacted residences surrounding PKCT.

23 Page 11 Table 4-2 Responsibilities for Noise Monitoring Location Description Residential Receivers 1 Corner of Swan and Kembla Sts Swan St, between Keira and Corrimal Sts 2 Corner of Swan and Corrimal Sts Swan St, east of Corrimal Sts 3 Corner of Keira and Fox Sts Keira St, between Swan and Fox Sts 4.4 Monitoring Protocol To adequately sample the noise environment surrounding PKTC bi-annual monitoring will be conducted. Noise monitoring needs only to be conducted at night as this would be the most appropriate time to conduct the measurement for the following reasons: The site operates 24 hours without any operational discrimination between day, evening and night. During the night, the lowest criterion applies and as such compliance with this criterion will lead to compliance during the evening and night. Atmospheric conditions that enhance noise propagation during the night are more likely to occur during the night. Given the generally lower ambient noise levels in the area at night, there is a higher chance that noise from PKCT would detected. Monitoring shall be bi-annually for a single night time period during Winter and Summer. The frequency of monitoring shall be reviewed after 12 months of operations. The Conditions of Approval require both attended and unattended noise monitoring however, the acoustic environment in the area is complex and given the fact that the residential receivers are separated by roads and a park, unattended noise monitoring is unlikely to provide any useful information regarding the noise from PKCT. Noise levels other than from PKCT need to be excluded from the measured level. As such, traditional attended noise monitoring using a unidirectional sound level meter is not suitable for this noise environment. The noise environment around PKCT is dominated by traffic noise from all areas and other industrial sites around the area which unidirectional noise monitoring can not discern. Therefore, the directional BarnOwl unattended noise monitoring system will be utilised for the noise monitoring. Using the directional BarnOwl system will provide the opportunity for identifying noise from the PKCT site (i.e. PKCT direction) and where measureable, quantify such levels.

24 Page 12 Figure 4-1 PKCT and Surrounding Receivers Residenc N Attended noise monitoring would be conducted at each of the three locations throughout the night (10.00pm to 7.00am). The monitoring interval shall be a 15 minute period with at least two intervals captured. In the event that monitoring is to be conducted during the day or evening, a single monitoring period shall be sufficient. The representative arc used for the directional noise monitor for each measurement location is presented in Figures 4-2, 4-3 and 4-4. Both the exact monitoring location and arc used may change slightly in an event where noise from nearby activities might interfere with the noise measurement. It should be noted that BarnOwl measures in 5 degree increments.

25 Page 13 Received levels from various noise sources would be noted during attended monitoring and particular attention will be paid to the extent of the PKCT noise contribution, if any. As a minimum for each receptor location, the L Aeq PKCT Direction (in the absence of any other noise) shall be quantified. This parameter would be calculated from measurements using the BarnOwl directional noise monitoring system (refer to Appendix B) and will be assessed against the criteria. The L A90 parameter will also be recorded as well as any maximum noise levels. If, at any time during monitoring, meteorological conditions exceed the conditions identified under Note (b) of Section 3-2, monitoring and reporting will still be carried out, however it will be outlined within the report that meteorological conditions were in exceedance of applicable levels, and as such the limits identified within Section 3-2 will not apply to the results obtained under such conditions. In addition, meteorological conditions will be obtained for the time of monitoring. This is to include wind speed and direction as well as data suitable for quantifying the presence or otherwise of temperature inversions from PKCT s two weather stations.

26 Page 14 Figure 4-2 Noise Measurement Sector for Location 1 Location 1 40 degrees

27 Page 15 Figure 4-3 Noise Measurement Sector for Location 2 Location 2 30 degrees

28 Page 16 Figure 4-4 Noise Measurement Sector for Location 3 Location 30 degrees 4.5 Summary of Attended Monitoring Frequency: Monitoring shall bi-annually for a single night time period within the winter and summer seasonal period.

29 Page 17 Interval: Attended noise monitoring would be conducted at each of the three locations throughout the night (10.00pm to 7.00am). The monitoring interval shall be a 15 minute period with a minimum two measurements to be conducted for the night time period. Parameters: Parameters to be recorded includes L Amax, L Aeq, 15min and L A90, 15min. Instruments: Instruments used for unattended monitoring shall be the BarnOwl direction noise monitoring system. Directional noise monitoring provides source detection and analysis of noise from the PKCT (See Figure 4-2, 4-3 and 4-4). Locations: BarnOwl uses 3 microphones spaced 500mm apart. The microphone signals are digitised using 24-bit, state-of-the-art A-D conversion. Specially-developed, optimised signal analysis software allows inter-microphone time differences (and therefore source directions) to be evaluated for a ½-second noise sample while the next sample is being acquired. BarnOwl can therefore provide real time tracking of noise sources, with source locations displayed on a monitor and/or saved for later analysis. The system can simultaneously record total noise, and a filtered signal excluding high-frequency sources such as insects. BarnOwl measures in 5 degree increments. Measurements methodology shall be in general compliance with Australian Standard 1055 Acoustics- Description and Measurement of Environmental Noise. Pre and post calibrations shall be recorded. Observation Logs: Location 1 Corner Swan and Kembla Streets; Location 2 Corner Swan and Corrimal Streets; and Location 3 Corner Keira and Fox Streets. Outdoor noise levels should normally be measured 1.2m 1.5m above ground level. The position(s) should be located within the apparent boundaries of land or within 30m of an effected residential receiver. The arc used shall be recorded for each location. During the noise measurements, the operator shall record any significant noise sources generated on-site by PKCT. It is recommended that any observations of noise from PKCT trucks are also taken. In addition the general ambient noise and weather are to be recorded. Following the completion of measurements, PKCT shall provide Wilkinson Murray (WM) with a summary of the site activities that occurred during the monitoring period. The summary shall include number of truck/rail movements, ships loaded and times. 5. Reporting The following information should be provided in the compliance noise measurement

30 Page 18 report. 1. Description of Source(s) and Surroundings The report should include the following: description of the sound source(s); location of source(s); description and sketch of physical environment e.g. trees, structures, reflecting objects, topographical features, and any other relevant features; photographs if appropriate; operating conditions of sound source(s). 2. Instrumentation For all items of equipment used for the measurements, including calibration equipment, the following information should be recorded: name; manufacturer; type; serial number(s) (also of microphones, if removable); record of field calibration; and; date of most recent laboratory calibration. 3. Acoustic Data The report should include the following, as appropriate: location(s) of the measurement position(s), and microphone orientations; type of noise being measured; noise levels measured; frequency weighting and time-weighting characteristic used for each measurement; duration of each measurement period; background noise level with the source not in operation if possible; date and time when each measurement was performed (include justification

31 Page 19 of measurement period); tonality adjustment; tonality adjustment; impulsiveness adjustment; and any other data considered appropriate. 4. Weather Data All noise measurements shall be accompanied by both qualitative and quantitative weather data throughout the duration of the noise survey. The report should include the following, as appropriate: mean wind speed; mean wind direction; Rain fall; Sigma theta and Pasquill stability class. 5. Site Operational Reports PKCT shall provide WM with a summary of all operations that occurred during each noise monitoring period. The summary should include the following: Truck movements. Rail movements and start/stop time for unloading. Ship loading and start/stop time for loading. 6. Statement of Compliance A noise compliance monitoring statement will be submitted for each monitoring period. The Report will report compliance with the operational noise limits specified in the DPI Approval.

32 Page Review Monitoring results will be reviewed on a bi-annual basis following the conclusion of the monitoring period by the Risk Manager to assess compliance with the noise criteria presented in Section Corrective Action In the event that the monitoring program or local community identifies an exceedance of the noise criteria stipulated in the development consent, the Risk Manager will investigate the noise source and appropriate corrective action will be undertaken. In the event that the investigation determines that noise from PKCT operations is likely to be responsible for an exceedance of the noise criteria at nearby residences the Director-General of DPI will be notified. Monitoring results will be published in PKCT s Annual Environmental Management Report. 6.2 Complaints A procedure for handling complaints has been implemented as part of the PKCT Environmental Management System (EMS) to ensure a consistent approach to handling any complaints. All legitimate complaints will be investigated by the PKCT Risk Manager. Feedback to the complainant will be provided. In addition to the monitoring outlined in this plan, if PKCT receives a complaint regarding noise at a particular location, specific monitoring may be undertaken to quantify the potential noise impact. 6.3 Review The noise monitoring program is to be reviewed in consultation with OEH and DPI at least every three years. The review will reflect changes in environmental expectations technology and operational procedures. If no exceedance of the criteria occurs for 6 years noise monitoring will not be required to continue.

33 APPENDIX A GLOSSARY

34 Appendix A-1 GLOSSARY Most environments are affected by environmental noise which continuously varies, largely as a result of road traffic. To describe the overall noise environment, a number of noise descriptors have been developed and these involve statistical and other analysis of the varying noise over sampling periods, typically taken as 15 minutes. These descriptors, which are demonstrated in the graph overleaf, are here defined. Maximum Noise Level (L Amax ) The maximum noise level over a sample period is the maximum level, measured on fast response, during the sample period. db(a) A-weighted decibels. The ear is not as effective in hearing low frequency sounds as it is hearing high frequency sounds. That is, low frequency sounds of the same db level are not heard as loud as high frequency sounds. The sound level meter replicates the human response of the ear by using an electronic filter which is called the A filter. A sound level measured with this filter switched on is denoted as db(a). Practically all noise is measured using the A filter. Frequency Frequency is synonymous to pitch. Sounds have a pitch which is peculiar to the nature of the sound generator. For example, the sound of a tiny bell has a high pitch and the sound of a bass drum has a low pitch. Frequency or pitch can be measured on a scale in units of Hertz or Hz. Impulsive Noise Having a high peak of short duration or a sequence of such peaks. A sequence of impulses in rapid succession is termed repetitive impulsive noise. Intermittent Noise The level suddenly drops to that of the background noise several times during the period of observation. The time during which the noise remains at levels different from that of the ambient is one second or more. L A1 The L A1 level is the noise level which is exceeded for 1% of the sample period. During the sample period, the noise level is below the L A1 level for 99% of the time. L A10 The L A10 level is the noise level which is exceeded for 10% of the sample period. During the sample period, the noise level is below the L A10 level for 90% of the time. The L A10 is a common noise descriptor for environmental noise and road traffic noise. L A90 The L A90 level is the noise level which is exceeded for 90% of the sample period. During the sample period, the noise level is below the L A90 level for 10% of the time. This measure is commonly referred to as the background noise level. L Aeq The equivalent continuous sound level (L Aeq ) is the energy average of the varying noise over the sample period and is equivalent to the level of a constant noise which contains the same energy as the varying noise environment. This measure is also a common measure of environmental noise and road traffic noise. ABL The Assessment Background Level is the single figure background level representing each assessment period (daytime, evening and night time) for each day. It is determined by calculating the 10 th percentile (lowest 10 th percent) background level (L A90 ) for each period. RBL The Rating Background Level for each period is the median value of the ABL values for the period over all of the days measured. There is therefore an RBL value for each period daytime, evening and night time.

35 Sound Pressure Level (dba) Appendix A-2 Sound Absorption The ability of a material to absorb sound energy through its conversion into thermal energy. Sound Level Meter An instrument consisting of a microphone, amplifier and indicating device, having a declared performance and designed to measure sound pressure level. Sound Pressure Level The level of noise, usually expressed in decibels, as measured by a standard sound level meter with a microphone. Tonal Noise Containing a prominent frequency and characterised by a definite pitch. 60 Typical Graph of Sound Pressure Level vs Time L Amax L A1 L A10 L Aeq L A50 L A :00 3:00 6:00 9:00 12:00 15:00 Monitoring or Survey Period (5 sec samples)

36 APPENDIX B BARNOWL DIRECTIONAL NOISE MONITORING SYSTEM

37

38

CALGA SAND QUARRY ATTENDED COMPLIANCE NOISE MONITORING 12 APRIL 2017 REPORT NO E VERSION A APRIL 2017 PREPARED FOR

CALGA SAND QUARRY ATTENDED COMPLIANCE NOISE MONITORING 12 APRIL 2017 REPORT NO E VERSION A APRIL 2017 PREPARED FOR ATTENDED COMPLIANCE NOISE MONITORING 12 APRIL 2017 REPORT NO. 01127-E VERSION A APRIL 2017 PREPARED FOR HANSON CONSTRUCTION MATERIALS PTY LTD LOT 151 PEATS RIDGE ROAD CALGA NSW 2250 DOCUMENT CONTROL Version

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring February 2018 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring February 2018 Reference:

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring May 2018 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring May 2018 Reference: Report date:

More information

Noise Monitoring Program

Noise Monitoring Program for Document Table of Contents for... 1 1 Purpose... 3 1.1 Purpose... 3 2 Noise Impact Assessment Criteria... 3 2.1 Noise Criteria... 3 3 Measurement and Evaluation... 6 3.1 Monitoring Locations... 6 3.2

More information

OneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017

OneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017 OneSteel Recycling Pty Ltd 14-Jul-2017 60493017 OneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017 NATA ACCREDITATION No. 2778 (14391) Accredited for compliance with ISO/IEC 17025 Testing

More information

Ashton Coal. Environmental Noise Monitoring May Prepared for Ashton Coal Operations Pty Ltd

Ashton Coal. Environmental Noise Monitoring May Prepared for Ashton Coal Operations Pty Ltd Ashton Coal Environmental Noise Monitoring May 2018 Prepared for Ashton Coal Operations Pty Ltd Page i Ashton Coal Environmental Noise Monitoring May 2018 Reference: Report date: 5 June 2018 Prepared for

More information

Boggabri Coal Mine. Environmental Noise Monitoring June Prepared for Boggabri Coal Operations Pty Ltd

Boggabri Coal Mine. Environmental Noise Monitoring June Prepared for Boggabri Coal Operations Pty Ltd Boggabri Coal Mine Environmental Noise Monitoring June 2017 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring June 2017 Reference: Report date: 5 July

More information

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 20 June Doc no QM-RP-4-0

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 20 June Doc no QM-RP-4-0 Orora Pty Ltd B9 Paper Mill EPL Compliance Quarterly noise monitoring report 20 June 2017 Doc no. 102-QM-RP-4-0 Orora Pty Ltd B9 Paper Mill - EPL Compliance Title Document no. Quarterly noise monitoring

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring April 2016 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring April 2016 Reference: Report

More information

Quarterly Noise Monitoring Report Austar Coal Mine Middle Road, Paxton NSW January 2007

Quarterly Noise Monitoring Report Austar Coal Mine Middle Road, Paxton NSW January 2007 REPORT 30-1664R1R0 Quarterly Noise Monitoring Report Austar Coal Mine Middle Road, Paxton NSW January 2007 PREPARED FOR P.O Box 806 Cessnock NSW 2325 14 MAY 2007 Quarterly Noise Monitoring Report Austar

More information

Boggabri Coal Mine. Environmental Noise Monitoring October Prepared for Boggabri Coal Operations Pty Ltd

Boggabri Coal Mine. Environmental Noise Monitoring October Prepared for Boggabri Coal Operations Pty Ltd Boggabri Coal Mine Environmental Noise Monitoring October 2017 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring October 2017 Reference: Report date:

More information

Cullen Valley Mine. Environmental Noise Monitoring Quarter 2, Prepared for Castlereagh Coal

Cullen Valley Mine. Environmental Noise Monitoring Quarter 2, Prepared for Castlereagh Coal Cullen Valley Mine Environmental Noise Monitoring Quarter 2, 2018 Prepared for Castlereagh Coal Page i Cullen Valley Mine Environmental Noise Monitoring Quarter 2, 2018 Reference: Report date: 28 June

More information

NOISE IMPACT ASSESSMENT 2016

NOISE IMPACT ASSESSMENT 2016 Panther Environmental Solutions Ltd, Unit 4, Innovation Centre, Institute of Technology, Green Road, Carlow, Ireland. Mobile: 087-8519284 Telephone /Fax: 059-9134222 Email: info@pantherwms.com Website:

More information

Muswellbrook Coal Company

Muswellbrook Coal Company Muswellbrook Coal Company Environmental ise Monitoring May 2015 Prepared for Muswellbrook Coal Page i Muswellbrook Coal Company Environmental ise Monitoring May 2015 Reference: Report date: 18 June 2015

More information

Wambo Coal Mine and Rail Spur

Wambo Coal Mine and Rail Spur Wambo Coal Mine and Rail Spur Environmental Noise Monitoring November 2017 Prepared for Wambo Coal Pty Limited Page i Wambo Coal Mine and Rail Spur Environmental Noise Monitoring November 2017 Reference:

More information

TECHNICAL REPORT 2016 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK.

TECHNICAL REPORT 2016 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK. TECHNICAL REPORT 16 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK. FOR Gabriel Kelly Group Environmental Manager Dairygold Food ingredients Castlefarm Mitchelstown

More information

Boggabri Coal Mine. Environmental Noise Monitoring August Prepared for Boggabri Coal Operations Pty Ltd

Boggabri Coal Mine. Environmental Noise Monitoring August Prepared for Boggabri Coal Operations Pty Ltd Boggabri Coal Mine Environmental Noise Monitoring August 2018 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring August 2018 Reference: Report date:

More information

Wambo Coal Mine and Rail Spur

Wambo Coal Mine and Rail Spur Wambo Coal Mine and Rail Spur Environmental Noise Monitoring September 2017 Prepared for Wambo Coal Pty Limited Page i Wambo Coal Mine and Rail Spur Environmental Noise Monitoring September 2017 Reference:

More information

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 11 August Doc no QM-RP-1-0

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 11 August Doc no QM-RP-1-0 Orora Pty Ltd B9 Paper Mill EPL Compliance Quarterly noise monitoring report 11 August 16 Doc no. 102-QM-RP-1-0 Orora Pty Ltd B9 Paper Mill - EPL Compliance Title Document no. Quarterly noise monitoring

More information

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000;

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000; 15 December 2017 Suite 6, Level 1, 146 Hunter Street Newcastle NSW 2300 PO Box 506 Pere Riini Quarry Manager Hanson Construction Materials Pty Ltd Level 5, 75 George Street Parramatta, NSW 2150 Newcastle,

More information

Attended Noise Monitoring Program

Attended Noise Monitoring Program 16 May 2018 Ref: 171356/7853 Muswellbrook Coal Company PO Box 123 Muswellbrook NSW 2333 RE: MAY 2018 NOISE MONITORING RESULTS MUSWELLBROOK COAL MINE This letter report presents the results of noise compliance

More information

Appendix 8. Draft Post Construction Noise Monitoring Protocol

Appendix 8. Draft Post Construction Noise Monitoring Protocol Appendix 8 Draft Post Construction Noise Monitoring Protocol DRAFT CPV Valley Energy Center Prepared for: CPV Valley, LLC 50 Braintree Hill Office Park, Suite 300 Braintree, Massachusetts 02184 Prepared

More information

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000;

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000; 10 October 2017 Suite 6, Level 1,, 146 Hunter Street Newcastle NSW 2300 PO Box 506 Pere Riini Quarry Manager Hanson Construction Materials Pty Ltd Level 5, 75 George Street Parramatta, NSW 2150 Newcastle,

More information

Attended Noise Monitoring Program

Attended Noise Monitoring Program 1 November 2018 Ref: 171356/8121 Muswellbrook Coal Company PO Box 123 Muswellbrook NSW 2333 RE: OCTOBER 2018 NOISE MONITORING RESULTS MUSWELLBROOK COAL MINE This letter report presents the results of noise

More information

Muswellbrook Coal Company

Muswellbrook Coal Company Muswellbrook Coal Company Environmental Noise Monitoring November 2015 Prepared for Muswellbrook Coal Page i Muswellbrook Coal Company Environmental Noise Monitoring November 2015 Reference: Report date:

More information

Pfizer Ireland Pharmaceuticals

Pfizer Ireland Pharmaceuticals Allegro Acoustics Limited, Unit 2A Riverside, Tallaght Business Park, Tallaght, Dublin 24 Tel/Fax: +33 () 1 4148 Pfizer Ireland Pharmaceuticals Pfizer Grange Castle, Grange Castle Business Park, Clondalkin,

More information

Wambo Coal Mine and Rail Spur

Wambo Coal Mine and Rail Spur Wambo Coal Mine and Rail Spur Environmental Noise Monitoring August 2017 Prepared for Wambo Coal Pty Limited Page i Wambo Coal Mine and Rail Spur Environmental Noise Monitoring August 2017 Reference: Report

More information

Rehab Glassco. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only.

Rehab Glassco. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only. Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre, Ennis Road, Limerick Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare Environmental

More information

BASELINE NOISE MONITORING SURVEY

BASELINE NOISE MONITORING SURVEY t m s environment ltd TMS Environment Ltd 53 Broomhill Drive Tallaght Dublin 24 Phone: +353-1-4626710 Fax: +353-1-4626714 Web: www.tmsenv.ie BASELINE NOISE MONITORING SURVEY UNIVERSITY COLLEGE DUBLIN Report

More information

Glassco Recycling. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only.

Glassco Recycling. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only. Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre, Ennis Road, Limerick. info@axisenv.ie 00353 61 324587 Unit 4, Osberstown Industrial Park, Caragh

More information

Attended Noise Monitoring - Quarter Ending September 2013

Attended Noise Monitoring - Quarter Ending September 2013 Unity Mining Level 10, 350 Collins St Melbourne VIC 3000 Version: Page 2 PREPARED BY: ABN 29 001 584 612 Units 7-8, 26-28 Napier Close Deakin ACT 2600 Australia (PO Box 9344 Deakin ACT 2600 Australia)

More information

Muswellbrook Coal Company

Muswellbrook Coal Company Muswellbrook Coal Company June, 12 Environmental Noise Monitoring Prepared for Muswellbrook Coal Muswellbrook Coal Company June, 12 Environmental Noise Monitoring Reference: Report date: 9 August 12 Prepared

More information

REPORT PERIOD: JANUARY 01 MARCH

REPORT PERIOD: JANUARY 01 MARCH QUARTERLY NOISE MONITORING REPORT FOR EAST GALWAY LANDFILL REPORT PERIOD: JANUARY 01 MARCH 31 2018 IE LICENCE REF. NO. W0178-02 APRIL 2018 QUARTERLY NOISE MONITORING REPORT FOR EAST GALWAY LANDFILL REPORT

More information

APPENDIX K NAPIER PORT WHARF NO. 6 FUTURE PORT NOISE MAPS

APPENDIX K NAPIER PORT WHARF NO. 6 FUTURE PORT NOISE MAPS APPENDIX K NAPIER PORT WHARF NO. 6 FUTURE PORT NOISE MAPS PORT OF NAPIER WHARF 6 FUTURE PORT NOISE MAPS (2026) Rp 004 r02 2015784A 20 September 2016 84 Symonds Street PO Box 5811 Wellesley Street Auckland

More information

Orora Compliance Monitoring

Orora Compliance Monitoring Orora Compliance Monitoring ORORA LIMITED April Noise Monitoring 389_14 A 29 April 1 Orora Compliance Monitoring Project no: IA389 Document title: April Noise Monitoring Document no: 389_1429 Revision:

More information

Offaly County Council

Offaly County Council Derryclure Landfill Facility, Derryclure, Co. Offaly Annual Monitoring Report Waste Licence Reg. No. W0029-04 Report Date: th October 15 Fitz Scientific Unit 35A, Boyne Business Park, Drogheda, Co. Louth

More information

CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017.

CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017. CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017. Prepared for: CLARE COUNTY COUNCIL ÁRAS CONTAE AN CHLÁIR NEW ROAD ENNIS CO. CLARE 3156 May 16 th, 2017 EPA

More information

79 First Avenue Mob: FIVE DOCK NSW 2046 VENTILATED ACOUSTIC ENCLOSURE NOISE EMISSION ASSESSMENT ACOUSTIC SERVICES & ADVICE

79 First Avenue Mob: FIVE DOCK NSW 2046 VENTILATED ACOUSTIC ENCLOSURE NOISE EMISSION ASSESSMENT ACOUSTIC SERVICES & ADVICE Head Office Postal Address T 02 9908 1270 Suite 9 PO Box 270 F 02 9908 1271 38-46 Albany St Neutral Bay 2089 E info@acousticdynamics.com.au St Leonards 2065 ABN: 36 105 797 715 W www.acousticdynamics.com.au

More information

Wambo Coal Mine and Rail Spur

Wambo Coal Mine and Rail Spur Wambo Coal Mine and Rail Spur Quarter 1, 2013 Environmental Noise Monitoring Prepared for Wambo Coal Pty Limited Wambo Coal Mine and Rail Spur Quarter 1, 2013 Environmental Noise Monitoring Reference:

More information

Orora Compliance Monitoring

Orora Compliance Monitoring Orora Compliance Monitoring ORORA LIMITED April 2016 Noise Monitoring 038900_20160506 A 6 May 2016 Orora Compliance Monitoring Project no: Document title: IA038900 April 2016 Noise Monitoring Document

More information

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate Noise Management Plan Date 31/7/15 Issue No 2e DRAFT TABLE OF CONTENTS 1. Policy Statement 2. Introduction/Purpose 3. Responsibility and Authority

More information

W For inspection purposes only. This report shall not be reproduced except in full, without the approval of BnM Environmental.

W For inspection purposes only. This report shall not be reproduced except in full, without the approval of BnM Environmental. ANNUAL MONITORING OF ENVIRONMENTAL NOISE AT THE BORD NA MóNA KILBERRY COMPOST FACILITY IN COMPLIANCE WITH IED LICENCE, NO. W0198-01 For the Attention of: Site Work & Report Prepared by: Anua File Ref:

More information

Bloomfield Colliery. Quarterly Noise Monitoring. and Compliance Assessment September Report Number Q R2.

Bloomfield Colliery. Quarterly Noise Monitoring. and Compliance Assessment September Report Number Q R2. Bloomfield Colliery Quarterly Noise Monitoring and Compliance Assessment September 2015 Report Number Q59 630.01053-R2 15 October 2015 Bloomfield Collieries Four Mile Creek Road Ashtonfield NSW 2323 Version:

More information

Assured Monitoring Group

Assured Monitoring Group Assured Monitoring Group YARRANLEA SOLAR FARM NOISE & VIBRATION IMPACT ASSESSMENT JANUARY 2017 I3 CONSULTING PTY LTD Project ID. 10734 R_1 DATE OF RELEASE: 15/02/2017 Table 1: Document approval Name Position

More information

Xtratherm Limited Kells Road, Navan, Co Meath

Xtratherm Limited Kells Road, Navan, Co Meath Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre Ennis Road Limerick Kells Road, Navan, Co Meath Annual Environmental Noise Survey 2017 IPPC Licence

More information

Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex

Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex Report ref. PJ3159/13181 Date August 13 Issued to Cuadrilla Resources Limited Issued by Peter Jackson MSc MIOA

More information

Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014

Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014 Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014 Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014 Prepared by Umwelt (Australia) Pty Limited on behalf of Mackas Sand Pty Ltd

More information

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate Noise Management Plan Date November 2014 Issue No 1 TABLE OF CONTENTS 1. Introduction/Purpose 2. Responsibility and Authority 3. Noise Monitoring 4.

More information

Review of Baseline Noise Monitoring results and Establishment of Noise Criteria

Review of Baseline Noise Monitoring results and Establishment of Noise Criteria Appendix G Review of Baseline Noise Monitoring results and Establishment of Noise Criteria Environmental Management Plan G May 2014 Colton Coal Mine Aldershot, Queensland Review of Baseline Noise Monitoring

More information

Template Planning Condition on Amplitude Modulation Noise Guidance Notes

Template Planning Condition on Amplitude Modulation Noise Guidance Notes www.renewableuk.com Template Planning Condition on Amplitude Modulation Noise Guidance Notes December 2013 Template Planning Condition on Amplitude Noise Guidance Notes Modulation Introduction Introduction

More information

ACOUSTIC BARRIER FOR TRANSFORMER NOISE. Ruisen Ming. SVT Engineering Consultants, Leederville, WA 6007, Australia

ACOUSTIC BARRIER FOR TRANSFORMER NOISE. Ruisen Ming. SVT Engineering Consultants, Leederville, WA 6007, Australia ICSV14 Cairns Australia 9-12 July, 2007 ACOUSTIC BARRIER FOR TRANSFORMER NOISE Ruisen Ming SVT Engineering Consultants, Leederville, WA 6007, Australia Roy.Ming@svt.com.au Abstract In this paper, an acoustic

More information

Assessment of rail noise based on generic shape of the pass-by time history

Assessment of rail noise based on generic shape of the pass-by time history Proceedings of Acoustics 23 Victor Harbor 7-2 November 23, Victor Harbor, Australia Assessment of rail noise based on generic shape of the pass-by time history Valeri V. enchine, Jonathan Song Science

More information

McGill Environmental Ltd.

McGill Environmental Ltd. McGill Environmental Ltd. Coom, Glenville, Co. Cork Environmental Noise Survey Report Date: 7 th October 2016 For inspection purposes only. KD Environmental Ltd. 1 Swiftbrook Glen, Virginia, Co. Cavan

More information

Fundamentals of Environmental Noise Monitoring CENAC

Fundamentals of Environmental Noise Monitoring CENAC Fundamentals of Environmental Noise Monitoring CENAC Dr. Colin Novak Akoustik Engineering Limited April 03, 2013 Akoustik Engineering Limited Akoustik Engineering Limited is the sales and technical representative

More information

Compliance Noise Survey & Assessment

Compliance Noise Survey & Assessment John Trotter Compliance Noise Survey & Assessment Duralie Coal October 2009 Issued October 2009 Vipac Engineers & Scientists Ltd Hunter Valley / Newcastle, NSW REPORT NO: 29N-09-0002-TRP-470219-0 PREPARED

More information

ORICA AUSTRALIA PTY LTD. ENVIRONMENTAL NOISE AUDIT OVERVIEW

ORICA AUSTRALIA PTY LTD. ENVIRONMENTAL NOISE AUDIT OVERVIEW Postal Address P.O. Box 432 Gladesville N.S.W. 1675 AUSTRALIA A.C.N. 068 727 195 A.B.N. 19 068 727 195 Telephone: 02 9879 4544 Fax: 02 9879 4810 Email: AtkinsAcoustics@bigpond.com.au Atkins Acoustics and

More information

Soltec (Ireland) Limited Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report

Soltec (Ireland) Limited Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report 2013 Licence Number: W0115-01 Report Date: 09 th July 2013 Report Number: 3220-13-03 Version 0 AXIS environmental services 40 Coolraine

More information

Bickerdike Allen Partners

Bickerdike Allen Partners 25 CHURCH ROAD, SE19 ENTERTAINMENT NOISE ASSESSMENT Report to Kayode Falebita Kingsway International Christian Centre 3 Hancock Road Bromley-By-Bow London E3 3DA A9540/R01-A-HT 26/07/2012 CONTENTS Page

More information

Protocol for Ambient Level Noise Monitoring

Protocol for Ambient Level Noise Monitoring July 2015 Protocol for Ambient Level Noise Monitoring L pressure =10.log [10 (Lp/10) - 10 (LpBackground/10) ] L pressure = 10.log [10 (Lp/10) - 10 (LpBackground/10) ] CENTRAL POLLUTION CONTROL BOARD P

More information

Project: Mt Piper Power Station Ash Placement. Lamberts North Operational Noise Assessment March 2014

Project: Mt Piper Power Station Ash Placement. Lamberts North Operational Noise Assessment March 2014 Project: Mt Piper Power Station Ash Placement Lamberts North Operational Noise Assessment March 2014 Reference: 233710 Prepared for: EnergyAustralia NSW Revision: 2 25 March 2014 Mt Piper Power Station

More information

2. As such, Proponents of Antenna Systems do not require permitting of any kind from the Town.

2. As such, Proponents of Antenna Systems do not require permitting of any kind from the Town. Subject: Antenna Systems Policy Number: Date Developed: 2008/09 Date Approved: April 8, 2009 Lead Department: Planning and Development Date Modified: (if applicable) November 26, 2014 A. PROTOCOL STATEMENT:

More information

R e p o r t th A u g u s t

R e p o r t th A u g u s t N o ise Mon it o r ing R e p o r t L e g a c y W a y T u n n e l M o n i t o r i n g P o s t C o m m is s i o n ing T es ts V e n ti la t ion S t a c ks Jun e 20 1 6 R e p o r t 3557 4 th A u g u s t 2

More information

ENVIRONMENTAL NOISE MONITORING QUARTER 1, Northparkes Mines PO Box 995 Parkes NSW 2870

ENVIRONMENTAL NOISE MONITORING QUARTER 1, Northparkes Mines PO Box 995 Parkes NSW 2870 ENVIRONMENTAL NOISE MONITORING QUARTER 1, 2018 s PO Box 995 Parkes NSW 2870 Job No: J38252 Report issued: 25 June 2018 ESP ENVIRONMENTAL & SAFETY PROFESSIONALS A division of Enviro-Net Australia Pty. Ltd.

More information

Black. LWECS Site Permit. Stearns County. Permit Section:

Black. LWECS Site Permit. Stearns County. Permit Section: PERMIT COMPLIANCE FILING Permittee: Permit Type: Project Location: Docket No: Permit Section: Date of Submission : Black Oak Wind,, LLC LWECS Site Permit Stearns County IP6853/WS-10-1240 and IP6866/WS-11-831

More information

Rev2-18.Feb Safety Reliability Integrity Training Asset Support Design Support Troubleshooting

Rev2-18.Feb Safety Reliability Integrity Training Asset Support Design Support Troubleshooting KEYSBROOK ENVIRONMENTAL NOISE COMPLIANCE REPORTING Q1 2016 MZI RESOURCES LTD 1370900-5-100-Rev2-18.Feb.2016 www.svt.com.au Perth Brisbane Kuala Lumpur Bangkok Noise Vibration Corrosion Safety Reliability

More information

Roche Ireland Limited

Roche Ireland Limited Limited Clarecastle, Co. Clare Monitoring Report Industrial Emissions Licence Number P0012-05 Report Date: 1 st February 17 Fitz Scientific Unit 35A, Boyne Business Park, Drogheda, Co. Louth Report No.

More information

Noise Assessment for Planning Purposes - as per TAN11

Noise Assessment for Planning Purposes - as per TAN11 Noise Assessment for Planning Purposes - as per TAN11 Report No: 1703035R01A Report Status: Final Report (Amended) Dated: 23 October 2017 Purchase order No: n/a Prepared for: Garep Demirci 73 Spencer David

More information

Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING JULY 2013

Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING JULY 2013 Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING JULY 2013 September 2013 Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING JULY 2013 September 2013 Prepared by on behalf of Mackas Sand Pty Ltd Project

More information

Roche Ireland Limited

Roche Ireland Limited Roche Ireland Limited Clarecastle, Co. Clare Environmental Noise Monitoring Report Industrial Emissions Licence Number P0012-05 Report Date: 6 th October 17 Fitz Scientific Unit 35A, Boyne Business Park,

More information

Air Monitoring Directive Chapter 9: Reporting

Air Monitoring Directive Chapter 9: Reporting Air Monitoring Directive Chapter 9: Reporting Version Dec 16, 2016 Amends the original Air Monitoring Directive published June, 1989 Title: Air Monitoring Directive Chapter 9: Reporting Number: Program

More information

What We Heard Report Inspection Modernization: The Case for Change Consultation from June 1 to July 31, 2012

What We Heard Report Inspection Modernization: The Case for Change Consultation from June 1 to July 31, 2012 What We Heard Report Inspection Modernization: The Case for Change Consultation from June 1 to July 31, 2012 What We Heard Report: The Case for Change 1 Report of What We Heard: The Case for Change Consultation

More information

Noise Monitoring Program. for the. Integra North Open Cut Coal Mine

Noise Monitoring Program. for the. Integra North Open Cut Coal Mine . Integra Coal Operations Pty Ltd ABN: 96 118 030 998 Noise Monitoring Program for the Integra North Open Cut Coal Mine Including a Noise Management Protocol Integra Coal Operations Pty Ltd ABN: 96 118

More information

Statement of Evidence of N I Hegley

Statement of Evidence of N I Hegley IN THE MATTER AND IN THE MATTER of the Resource Management Act 1991 of Notices of Requirement to enable the construction, operation and maintenance of the City Rail Link. Statement of Evidence of N I Hegley

More information

Bloomfield Colliery. Quarterly Noise Monitoring and Compliance Assessment. September Report Number

Bloomfield Colliery. Quarterly Noise Monitoring and Compliance Assessment. September Report Number Report Number 630.01053 20 December 2016 Bloomfield Collieries Four Mile Creek Road Ashtonfield NSW 2323 Version: v1.0 Report Number 630.01053 20 December 2016 v1.0 Page 2 PREPARED BY: ABN 29 001 584 612

More information

Assessing the accuracy of directional real-time noise monitoring systems

Assessing the accuracy of directional real-time noise monitoring systems Proceedings of ACOUSTICS 2016 9-11 November 2016, Brisbane, Australia Assessing the accuracy of directional real-time noise monitoring systems Jesse Tribby 1 1 Global Acoustics Pty Ltd, Thornton, NSW,

More information

Pipeline Blowdown Noise Levels

Pipeline Blowdown Noise Levels Pipeline Blowdown Noise Levels James Boland 1, Henrik Malker 2, Benjamin Hinze 3 1 SLR Consulting, Acoustics and Vibration, Brisbane, Australia 2 Atkins Global, Acoustics, London, United Kingdom 3 SLR

More information

SYDNEY INTERNATIONAL CONTAINER TERMINALS Noise Compliance Assessment July 2015 Rp002 r SY. 23 October 2015

SYDNEY INTERNATIONAL CONTAINER TERMINALS Noise Compliance Assessment July 2015 Rp002 r SY. 23 October 2015 SYDNEY INTERNATIONAL CONTAINER TERMINALS Noise Compliance Assessment July 2015 Rp002 r02 2014432SY 23 October 2015 4/46 Balfour St Chippendale NSW 2008 T: +612 9282 9422 Fax: +612 9281 3611 www.marshallday.com

More information

University of York Heslington East Campus Details of Noise Modelling and Noise Survey. Report ref AAc/ /R01

University of York Heslington East Campus Details of Noise Modelling and Noise Survey. Report ref AAc/ /R01 Heslington East Campus Details of Noise Modelling and Noise Survey Report ref Heslington East Campus Details of Noise Modelling and Noise Survey January 2008 Arup Acoustics Admiral House, Rose Wharf, 78

More information

Terms of Reference of Aircraft Noise at IGI Airport, New Delhi

Terms of Reference of Aircraft Noise at IGI Airport, New Delhi Terms of Reference of Aircraft Noise at IGI Airport, New Delhi In order to determine the noise impact from aircraft flights and identify potential measures to reduce the noise impact, an Aircraft Noise

More information

Standard Guide for Preparing a Measurement Plan for Conducting Outdoor Sound Measurements 1

Standard Guide for Preparing a Measurement Plan for Conducting Outdoor Sound Measurements 1 Designation: E 1779 96a Standard Guide for Preparing a Measurement Plan for Conducting Outdoor Sound Measurements 1 This standard is issued under the fixed designation E 1779; the number immediately following

More information

WesPac Pittsburg Energy Infrastructure Project. Noise Assessment Report

WesPac Pittsburg Energy Infrastructure Project. Noise Assessment Report WesPac Pittsburg Energy Infrastructure Project Noise Assessment Report Prepared for WesPac Energy Pittsburg LLC And Oiltanking North America LLC Prepared by TRC 1200 Wall Street West, 2 nd Floor Lyndhurst,

More information

VCE Systems Engineering: Administrative information for Schoolbased Assessment in 2019

VCE Systems Engineering: Administrative information for Schoolbased Assessment in 2019 VCE Systems Engineering: Administrative information for Schoolbased Assessment in 2019 Units 3 and 4 School-assessed Task The School-assessed Task contributes 50 per cent to the study score and is commenced

More information

Rix's Creek Coal Mine

Rix's Creek Coal Mine Rix's Creek Coal Mine Environmental Noise Monitoring September 2018 Prepared for Rix's Creek Pty Ltd Page i Rix's Creek Coal Mine Environmental Noise Monitoring September 2018 Reference: Report date: 5

More information

Cymbaluk Noise Complaints

Cymbaluk Noise Complaints Decision 20259-D01-2015 Cymbaluk Noise Complaints December 22, 2015 Alberta Utilities Commission Decision 20259-D01-2015 Cymbaluk Noise Complaints Proceeding 20259 Application 20259-A001 December 22, 2015

More information

Sydney Metro City and Southwest North Corridor Works Technical Report - Noise Monitoring OOHW P1-6: 25 to 26 August 2018

Sydney Metro City and Southwest North Corridor Works Technical Report - Noise Monitoring OOHW P1-6: 25 to 26 August 2018 1/8 Project Title Client Document Reference No. Laing O Rourke Project No. Noise Monitoring Sydney Metro City and Southwest LOR-NCW-Noise Monitoring WE08_ OOHW P1-6 - 250818_260818.docx K38 Document Date

More information

Wambo Coal Mine and Rail Spur

Wambo Coal Mine and Rail Spur Wambo Coal Mine and Rail Spur Environmental Noise Monitoring Quarter 4 2009 Prepared for Wambo Coal Pty Limited Wambo Coal Mine and Rail Spur Quarter 4, 2009 Environmental Noise Monitoring Reference: 09244_R01.doc

More information

Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC. Final Report Rev 1

Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC. Final Report Rev 1 Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC Final Report Rev 1 Noise Impact Assessment RWDI # 1502274 SUBMITTED TO Paul Dufault Project Manager Metro Vancouver 4330

More information

ABERDEEN HARBOUR EXPANSION PROJECT November Volume 3: Technical Appendices

ABERDEEN HARBOUR EXPANSION PROJECT November Volume 3: Technical Appendices ABERDEEN HARBOUR EXPANSION PROJECT November 2015 Volume 3: Technical Appendices Appendix 20-B BASELINE NOISE SURVEY 20-B BASELINE NOISE SURVEY Noise Sensitive Receptors A desk-based study and site walkover

More information

Phase 2 Executive Summary: Pre-Project Review of AECL s Advanced CANDU Reactor ACR

Phase 2 Executive Summary: Pre-Project Review of AECL s Advanced CANDU Reactor ACR August 31, 2009 Phase 2 Executive Summary: Pre-Project Review of AECL s Advanced CANDU Reactor ACR-1000-1 Executive Summary A vendor pre-project design review of a new nuclear power plant provides an opportunity

More information

Standard Guide for Measurement of Outdoor A-Weighted Sound Levels 1

Standard Guide for Measurement of Outdoor A-Weighted Sound Levels 1 Designation: E 1014 84 (Reapproved 1995) e1 AMERICAN SOCIETY FOR TESTING AND MATERIALS 100 Barr Harbor Dr., West Conshohocken, PA 19428 Reprinted from the Annual Book of ASTM Standards. Copyright ASTM

More information

Project: Mt Piper Power Station Ash Placement. Lamberts North Operational Noise Assessment March 2016

Project: Mt Piper Power Station Ash Placement. Lamberts North Operational Noise Assessment March 2016 Project: Mt Piper Power Station Ash Placement Lamberts North Operational Noise Assessment March 2016 Reference: 246493-002 Prepared for: EnergyAustralia NSW Revision: 3 26 April 2016 Document Control Record

More information

1 SERVICE DESCRIPTION

1 SERVICE DESCRIPTION DNV GL management system ICP Product Certification ICP 4-6-3-5-CR Document number: ICP 4-6-3-5-CR Valid for: All in DNV GL Revision: 2 Date: 2017-05-05 Resp. unit/author: Torgny Segerstedt Reviewed by:

More information

National Grid s commitments when undertaking works in the UK. Our stakeholder, community and amenity policy

National Grid s commitments when undertaking works in the UK. Our stakeholder, community and amenity policy National Grid s commitments when undertaking works in the UK Our stakeholder, community and amenity policy Introduction This document describes the ten commitments we have made to the way we carry out

More information

Appendix L Noise Technical Report. Rehabilitation and Restoration of the Longfellow Bridge

Appendix L Noise Technical Report. Rehabilitation and Restoration of the Longfellow Bridge Appendix L Noise Technical Report Rehabilitation and Restoration of the Longfellow Bridge Noise Technical Report Rehabilitation and Restoration of the Longfellow Bridge Boston, MA May, 2011* Prepared by

More information

Bancroft & Piedmont Cellular Facility

Bancroft & Piedmont Cellular Facility Page 1 of 19 Environmental Noise Analysis Bancroft & Piedmont Cellular Facility Berkeley, California BAC Job # 2015-177 Prepared For: Complete Wireless Consulting Attn: Ms. Kim Le 2009 V Street Sacramento,

More information

Small craft -Measurement of sound pressure level of airborne sound emitted by powered recreational craft

Small craft -Measurement of sound pressure level of airborne sound emitted by powered recreational craft Small craft -Measurement of sound pressure level of airborne sound emitted by powered recreational craft Introduction This Standard describes the method for determining the pass by sound level emitted

More information

Status: Rev: Comments Date: Author: Reviewer:

Status: Rev: Comments Date: Author: Reviewer: PAKENHAM EAST PRECINCT STRUCTURE PLAN CITY GATE NOISE ASSESSMENT Rp 002 R03 20171135 28 May 2018 Marshall Day Acoustics Pty Ltd ABN: 53 470 077 191 6 Gipps Street Collingwood VIC 3066 Australia T: +613

More information

THE CASE FOR SPECTRAL BASELINE NOISE MONITORING FOR ENVIRONMENTAL NOISE ASSESSMENT.

THE CASE FOR SPECTRAL BASELINE NOISE MONITORING FOR ENVIRONMENTAL NOISE ASSESSMENT. ICSV14 Cairns Australia 9-12 July, 2007 THE CASE FOR SPECTRAL BASELINE NOISE MONITORING FOR ENVIRONMENTAL NOISE ASSESSMENT Michael Caley 1 and John Savery 2 1 Senior Consultant, Savery & Associates Pty

More information

CHAPTER 48 NOISE POLLUTION

CHAPTER 48 NOISE POLLUTION CHAPTER 48 NOISE POLLUTION 48.01 Purpose 48.06 Sound Equipment and Amplifying Equipment 48.02 Definitions 48.07 Use of Sound Equipment for Commercial 48.03 Application Advertising Prohibited 48.04 Maximum

More information

Duralie Coal Mine. Quarterly Compliance Noise Monitoring. November Report Number R December 2016.

Duralie Coal Mine. Quarterly Compliance Noise Monitoring. November Report Number R December 2016. Duralie Coal Ltd PO Box 168, GLOUCESTER NSW 2422 www.duraliecoal.com.au Version: v1.1 Page 2 PREPARED BY: ABN 29 001 584 612 10 Kings Road New Lambton NSW 2305 Australia (PO Box 447 New Lambton NSW 2305

More information