1 Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report 2013 Licence Number: W Report Date: 09 th July 2013 Report Number: Version 0 AXIS environmental services 40 Coolraine Heights, Old Cratloe Road, Limerick Tel (061) Mobile(087) info@axisenv.ie
2 Report Content 1.0 Executive Summary Introduction Methods Employed Monitoring Locations Daytime Noise Measurements Conclusions. 12 Report No: Page 2 of 19 Version 0
3 1.0 Executive Summary are required as part of licence W : to carry out a noise survey at the installation on an annual basis. The noise monitoring positions have been located at site boundaries and in close proximity to other industrial and office units. AXIS environmental services were commissioned to carry out the survey after proposal acknowledgment and acceptance by s Environmental Department. For consistency in reporting, and the Agency have agreed noise monitoring locations at the installation. The same locations will be used for each monitoring round, unless circumstances prevent an accurate survey been carried out. In this event, Soltec (Ireland) Limited will agree new monitoring points with the Agency prior to the change. Four monitoring points were located within the boundary of the site. There were five points monitored in total during the survey period for broadband and one third octave frequency analyses. is located in Zone A, Mullingar Business Park, Mullingar, Co Westmeath. The surrounding facilities include a tyre centre, Eircom & general industrial warehouses & factories. There is a railway line at the rear of the property. The estate is quite busy with traffic and activities on-going at alternative industries in the vicinity. All operations in Soltec continued as normal during the day time survey survey. Report No: Page 3 of 19 Version 0
4 2.0 Introduction As part of compliance monitoring at, noise monitoring is carried out at a number of boundary locations and one off site monitoring point in the vicinity of the installation. Condition 8 of the Waste Licence W outlines the following requirements: 8.6. Noise monitoring The location of the noise monitoring points shall be as per Attachment J.7 of the application. Noise Monitoring Locations Location Note 1 Measurement Note 2 Frequency N1 North West Corner N2 South East Boundary N3 South West Boundary N4 North East Corner N5 Southern Boundary L Aeq 30 minutes L Aeq 30 minutes L Aeq 30 minutes L Aeq 30 minutes L Aeq 30 minutes Annual Annual Annual Annual Annual Note 1: Or at any other locations specified by the Agency. Note 2: International Standards Organisation. ISO Acoustics - description and Measurement of Environmental noise. Parts 1, 2 and 3. Report No: Page 4 of 19 Version 0
5 3.0 Methods Monitoring was carried out in strict accordance with ISO 1996 Parts 1 3, Description and Measurement of Environmental Noise. Reference was also made to the EPA guidelines NG4 Guidance Note for Noise: Licence Applications, Surveys and Assessments in Relation to Scheduled Activities April 2012, in conjunction with the frequently asked questions issued by the Agency in August Table 2: Equipment Details Meter No 2 Meter No 3 Manufacturer Cirrus Optimus Green Cirrus Optimus Green Model CR:171B CR:172B Serial Number G G Firmware V V Calibrator CR:515 Acoustic Calibrator CR:515 Acoustic Calibrator Microphone B&K B&K Windshield Type UA:237 90mm Foam Windshield UA:237 90mm Foam Windshield Calibration Date Noise Meter 18 th Nov nd Aug Certificate Number Calibrator 18 th Nov th Nov Certificate Number On site SLM calibration Prior to Survey Calibration Offset Post Survey Frequency Weighting A - Broadband A - Broadband Meter Response Time Fast Fast Report No: Page 5 of 19 Version 0
6 4.0 Monitoring Locations 4.1 N1 This monitoring point was located in the North western corner of the site. This position is located between activities on site and the nearest noise sensitive location to the north east. The main sources of noise noted at this point were as follows: Background traffic in Mullingar Business Park i.e. Forklifts reversing, loud truck engines Birds chirping in surrounding vegetation Noise from air extraction unit on site approx 25m from monitoring point. Humming Noise from Industrial cooling unit at side of building approx 35m from monitoring point. Nearby heavy gate being unlocked and opened by employee approx 5m from monitoring point. 4.2 N2 This monitoring point was located at the south eastern corner of the site. This position is located between the Eircom car park entrance gate and the car park. The main sources of noise noted during the survey include the following: 4.3 N3 Truck reversing at nearby tyre shop (Mileage Tyres) approx 50m from monitoring point Birds chirping in surrounding vegetation. Person talking on phone in Eircom carpark approx 10m from monitoring point. Car entering Eircom car park. Backgournd traffic in the estate. Train movement on the train line behind Soltec. This monitoring point was located on the south western boundary of the installation between Soltec and the Eircom building. The main sources of noise recorded include the following: Birds chirping in nearby vegetation Background Traffic in Mullingar Business Park i.e. Forklift driving/reversing in Eircom. People chatting both in Soltec building and outside of building. Humming noise from industrial cooling unit at side of Soltec building approx 25m from monitoring point. Eircom s gates opening and closing. Report No: Page 6 of 19 Version 0
7 4.4 N4 The monitoring point was located to the north eastern corner of the site behind Sally s Salon Supplies in a semi-enclosed area. The main sources of noise recorded include the following: Birds chirping in the nearby vegetation Heavy gate at front of the site opening and closing; Train going by approx 20m from monitoring point Forklift loading truck and people talking Background noise in the industrial estate 4.5 N5 The monitoring point was located to the south of the site directly in front of the Eircom building. The noise meter was positioned between the Eircom boundary fencing and a road directly in front of Soltec (Ireland) limited. There was a range of noise sources recorded at this point. Traffic entering and leaving Eircom car park Engine left running idle Background Traffic in Mullingar Business Park Noise from truck engine and forklift as truck is being loaded approx 10m from monitoring point. Air-gun operating in nearby tyre shop (Mileage Tyres) approx 60m from monitoring point. Report No: Page 7 of 19 Version 0
8 5.0 Summary of Daytime Noise Measurements Noise Monitoring Location: N1 (Boundary Monitoring Point) Measured Noise Levels (db re. 2 x 10-5 Pa) Comments Period: Time L Aeq L AFMAX L A90 Daytime: 12: Arithmetic Average (db): Daytime Criterion, db L Ar,T: Evening: Evening Criterion, db L Ar,T: Night Time: Night time Criterion, db L Ar,T: Main noise sources include background traffic in Mullingar Business Park, Forklift operating in the yard, Birds chirping in surrounding vegetation, Noise from air extraction unit on site, Humming noise from industrial cooling unit and Nearby heavy gate being unlocked and opened by employee approx 5m from monitoring point. the evening period. The site is not defined as a new or revised licence since the guidelines were issued in the night time period. Weather Conditions: Daytime: Evening: Night Time: Temperature ( O C) Wind Speed (m/s) Wind Direction: Wind from NW - - Precipitation: 0mm - - Tonal Noise Assessment Daytime: Run 1: None - - Night Time: Compliance Status this is not a noise sensitive location therefore limits would not apply - Noise from Soltec would be more representative by use of the L A90 Report No: Page 8 of 19 Version 0
9 Noise Monitoring Location: N2 (Boundary Monitoring Point) Measured Noise Levels (db re. 2 x 10-5 Pa) Comments Period: Time L Aeq L AFMAX L A90 10: Daytime: Arithmetic Average (db): Daytime Criterion, db L Ar,T: Evening: Evening Criterion, db L Ar,T: Night Time: Night time Criterion, db L Ar,T: Weather Conditions: The main source of noise included: Tarffic movements from Eircom, air gun from the tyre fitters. An engine was left running close by. Person talking on phone in Eircom car park approx. 10m from monitoring point. Car entering Eircom car park. Background traffic in the estate. Train movement on the train line behind Soltec. the evening period. The site is not defined as a new or revised licence since the guidelines were issued in the night time period. Daytime: Evening: Night Time: Temperature ( O C) Wind Speed (m/s) Wind Direction: Wind from NW - - Precipitation: 0mm - - Tonal Noise Assessment Daytime: Run 1: None - - Night Time: Compliance Status this is not a noise sensitive location therefore limits would not apply - Noise from Soltec would be more representative by use of the L A90 Report No: Page 9 of 19 Version 0
10 Noise Monitoring Location: N3 (Boundary Monitoring Point) Measured Noise Levels (db re. 2 x 10-5 Pa) Comments Period: Time L Aeq L AFMAX L A90 14: Daytime: Arithmetic Average (db): The main source of noise during the survey was from an engine running idle in an adjacent facility. There was also noise from background traffic in the estate and birds continuously chirping. The ESB gate was opened and closed on several occasions during the survey. Daytime Criterion, db L Ar,T: Evening: Evening Criterion, db L Ar,T: Night Time: Night time Criterion, db L Ar,T: Weather Conditions: the evening period. The site is not defined as a new or revised licence since the guidelines were issued in the night time period. Daytime: Evening: Night Time: Temperature ( O C) Wind Speed (m/s) Wind Direction: Wind from NW - - Precipitation: 0mm - - Tonal Noise Assessment Daytime: Run 1: None - - Night Time: Compliance Status this is not a noise sensitive location therefore limits would not apply - the truck next door made representative monitoring at this location impossible on the day. Report No: Page 10 of 19 Version 0
11 Noise Monitoring Location: N4 (Boundary Monitoring Point) Measured Noise Levels (db re. 2 x 10-5 Pa) Comments Period: Time Daytime: L Aeq L AFMAX L A90 13: The main source of noise during the survey was background traffic in the estate and birds continuously chirping. Arithmetic Average (db): Daytime Criterion, db L Ar,T: Evening: Evening Criterion, db L Ar,T: Night Time: Night time Criterion, db L Ar,T: the evening period. The site is not defined as a new or revised licence since the guidelines were issued in the night time period. Weather Conditions: Daytime: Evening: Night Time: Temperature ( O C) Wind Speed (m/s) Wind Direction: Wind from NW - - Precipitation: 0mm - - Tonal Noise Assessment Daytime: Run 1: None - - Night Time: Compliance Status this is not a noise sensitive location therefore limits would not apply Noise from Soltec would be more representative by use of the L A90 Report No: Page 11 of 19 Version 0
12 Noise Monitoring Location: N5 (Boundary Monitoring Point) Measured Noise Levels (db re. 2 x 10-5 Pa) Comments Period: Time L Aeq L AFMAX L A90 14: Daytime: Arithmetic Average (db): This monitoring point was located in front of the eircom offices and yard. The main sources of noise were traffic associated with Eircom and HGV movement to and from their yard. There was a delivery to Eircom which had left the engine running throughout the survey. Daytime Criterion, db L Ar,T: Evening: Evening Criterion, db L Ar,T: Night Time: Night time Criterion, db L Ar,T: Weather Conditions: the evening period. The site is not defined as a new or revised licence since the guidelines were issued in the night time period. Daytime: Evening: Night Time: Temperature ( O C) Wind Speed (m/s) Wind Direction: Wind from NW - - Precipitation: 0mm - - Tonal Noise Assessment Daytime: Run 1: None - - Night Time: Compliance Status this is not a noise sensitive location therefore limits would not apply Report No: Page 12 of 19 Version 0
13 6.0 Conclusions Five points were monitored at Soltec Ireland Ltd as part of their Annual Environmental Survey in accordance with Condition 8 of their Waste License W There was a significant volume of noise being produced from adjacent yards and industries throughout the day. This noise was not in any way associated with activities on-going at Soltec. Monitoring points N3 and N5 were most notably impacted by this external noise sources. During lulls in this interference noise from Soltec would have been well within the licence requirement of 55dB(A). All locations survey would not be considered noise sensitive locations by definition in the EPA guidance note. Soltec is located in the middle of a busy industrial estate with continuous noise sources from other sites. Soltec was therefore considered to be in compliance with licence conditions as there was no impulsive or tonal noise produced on site. When interference noise was quietened, the noise levels from Soltec were well within licence requirements. The actual noise from Soltec would be better described by the L A90 from N1 to N4. Report No: Page 13 of 19 Version 0
14 Appendix I Report No: Page 14 of 19 Version 0
15 Report No: Page 15 of 19 Version 0
16 Report No: Page 16 of 19 Version 0
17 Report No: Page 17 of 19 Version 0
18 Report No: Page 18 of 19 Version 0
19 Appendix II Location Map Report No: Page 19 of 19 Version 0
Xtratherm Limited Kells Road, Navan, Co Meath
Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre Ennis Road Limerick Kells Road, Navan, Co Meath Annual Environmental Noise Survey 2017 IPPC Licence
More informationRehab Glassco. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only.
Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre, Ennis Road, Limerick Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare Environmental
More informationGlassco Recycling. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only.
Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre, Ennis Road, Limerick. info@axisenv.ie 00353 61 324587 Unit 4, Osberstown Industrial Park, Caragh
More informationOffaly County Council
Derryclure Landfill Facility, Derryclure, Co. Offaly Annual Monitoring Report Waste Licence Reg. No. W0029-04 Report Date: th October 15 Fitz Scientific Unit 35A, Boyne Business Park, Drogheda, Co. Louth
More informationRoche Ireland Limited
Limited Clarecastle, Co. Clare Monitoring Report Industrial Emissions Licence Number P0012-05 Report Date: 1 st February 17 Fitz Scientific Unit 35A, Boyne Business Park, Drogheda, Co. Louth Report No.
More informationRoche Ireland Limited
Roche Ireland Limited Clarecastle, Co. Clare Environmental Noise Monitoring Report Industrial Emissions Licence Number P0012-05 Report Date: 6 th October 17 Fitz Scientific Unit 35A, Boyne Business Park,
More informationMcGill Environmental Ltd.
McGill Environmental Ltd. Coom, Glenville, Co. Cork Environmental Noise Survey Report Date: 7 th October 2016 For inspection purposes only. KD Environmental Ltd. 1 Swiftbrook Glen, Virginia, Co. Cavan
More informationNOISE IMPACT ASSESSMENT 2016
Panther Environmental Solutions Ltd, Unit 4, Innovation Centre, Institute of Technology, Green Road, Carlow, Ireland. Mobile: 087-8519284 Telephone /Fax: 059-9134222 Email: info@pantherwms.com Website:
More informationW For inspection purposes only. This report shall not be reproduced except in full, without the approval of BnM Environmental.
ANNUAL MONITORING OF ENVIRONMENTAL NOISE AT THE BORD NA MóNA KILBERRY COMPOST FACILITY IN COMPLIANCE WITH IED LICENCE, NO. W0198-01 For the Attention of: Site Work & Report Prepared by: Anua File Ref:
More informationPfizer Ireland Pharmaceuticals
Allegro Acoustics Limited, Unit 2A Riverside, Tallaght Business Park, Tallaght, Dublin 24 Tel/Fax: +33 () 1 4148 Pfizer Ireland Pharmaceuticals Pfizer Grange Castle, Grange Castle Business Park, Clondalkin,
More informationREPORT PERIOD: JANUARY 01 MARCH
QUARTERLY NOISE MONITORING REPORT FOR EAST GALWAY LANDFILL REPORT PERIOD: JANUARY 01 MARCH 31 2018 IE LICENCE REF. NO. W0178-02 APRIL 2018 QUARTERLY NOISE MONITORING REPORT FOR EAST GALWAY LANDFILL REPORT
More informationTECHNICAL REPORT 2016 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK.
TECHNICAL REPORT 16 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK. FOR Gabriel Kelly Group Environmental Manager Dairygold Food ingredients Castlefarm Mitchelstown
More informationBASELINE NOISE MONITORING SURVEY
t m s environment ltd TMS Environment Ltd 53 Broomhill Drive Tallaght Dublin 24 Phone: +353-1-4626710 Fax: +353-1-4626714 Web: www.tmsenv.ie BASELINE NOISE MONITORING SURVEY UNIVERSITY COLLEGE DUBLIN Report
More informationNoise Monitoring Report For. Schloetter (Ireland) Ltd. Naas Enterprise Park, Naas, Co. Kildare
Bray (Co. Wicklow) 01 276 1428 Lisburn (Co. Antrim) 028 9262 6733 Birmingham (U.K.) 0121 673 1804 Blackrock (Co.Cork) 021 4536155 Noise Monitoring Report 2017 For Schloetter (Ireland) Ltd. Naas Enterprise
More informationCENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017.
CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017. Prepared for: CLARE COUNTY COUNCIL ÁRAS CONTAE AN CHLÁIR NEW ROAD ENNIS CO. CLARE 3156 May 16 th, 2017 EPA
More informationMALONE O REGAN. Annual Noise Survey Powerstown Landfill Industrial Emission Licence No. W March 2016
MALONE O REGAN March 2016 Powerstown Landfill Industrial Emission Licence No. W0025-04 Annual Noise Survey 2015 2B Richview Office Park, Clonskeagh, Dublin 14. Tel: +353 01 2602655 Fax: +353 01 2602660
More informationMuswellbrook Coal Company
Muswellbrook Coal Company Environmental Noise Monitoring November 2015 Prepared for Muswellbrook Coal Page i Muswellbrook Coal Company Environmental Noise Monitoring November 2015 Reference: Report date:
More informationQuarterly Noise Monitoring Report Austar Coal Mine Middle Road, Paxton NSW January 2007
REPORT 30-1664R1R0 Quarterly Noise Monitoring Report Austar Coal Mine Middle Road, Paxton NSW January 2007 PREPARED FOR P.O Box 806 Cessnock NSW 2325 14 MAY 2007 Quarterly Noise Monitoring Report Austar
More informationElectricity Supply to Africa and Developing Economies. Challenges and opportunities. Planning for the future in uncertain times
Electricity Supply to Africa and Developing Economies. Challenges and opportunities. Planning for the future in uncertain times 765 kv Substation Acoustic Noise Impact Study by Predictive Software and
More informationEnvironment Protection Authority (EPA), Industrial Noise Policy (INP) 2000;
15 December 2017 Suite 6, Level 1, 146 Hunter Street Newcastle NSW 2300 PO Box 506 Pere Riini Quarry Manager Hanson Construction Materials Pty Ltd Level 5, 75 George Street Parramatta, NSW 2150 Newcastle,
More informationMuswellbrook Coal Company
Muswellbrook Coal Company Environmental ise Monitoring May 2015 Prepared for Muswellbrook Coal Page i Muswellbrook Coal Company Environmental ise Monitoring May 2015 Reference: Report date: 18 June 2015
More informationAttended Noise Monitoring Program
1 November 2018 Ref: 171356/8121 Muswellbrook Coal Company PO Box 123 Muswellbrook NSW 2333 RE: OCTOBER 2018 NOISE MONITORING RESULTS MUSWELLBROOK COAL MINE This letter report presents the results of noise
More informationReview of Baseline Noise Monitoring results and Establishment of Noise Criteria
Appendix G Review of Baseline Noise Monitoring results and Establishment of Noise Criteria Environmental Management Plan G May 2014 Colton Coal Mine Aldershot, Queensland Review of Baseline Noise Monitoring
More informationAttended Noise Monitoring Program
16 May 2018 Ref: 171356/7853 Muswellbrook Coal Company PO Box 123 Muswellbrook NSW 2333 RE: MAY 2018 NOISE MONITORING RESULTS MUSWELLBROOK COAL MINE This letter report presents the results of noise compliance
More informationBlack. LWECS Site Permit. Stearns County. Permit Section:
PERMIT COMPLIANCE FILING Permittee: Permit Type: Project Location: Docket No: Permit Section: Date of Submission : Black Oak Wind,, LLC LWECS Site Permit Stearns County IP6853/WS-10-1240 and IP6866/WS-11-831
More informationITV CORONATION STREET PRODUCTION FACILITY, TRAFFORD WHARF ROAD ASSESSMENT OF POTENTIAL NOISE & VIBRATION IMPACT OF PROPOSED METROLINK LINE
ITV CORONATION STREET PRODUCTION FACILITY, TRAFFORD WHARF ROAD ASSESSMENT OF POTENTIAL NOISE & VIBRATION IMPACT OF PROPOSED METROLINK LINE On behalf of: ITV plc Report No. 22396.01v1 October 2014 ITV CORONATION
More informationLiddell Coal Operations
Liddell Coal Operations Environmental Noise Monitoring February 2018 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring February 2018 Reference:
More informationOrora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 20 June Doc no QM-RP-4-0
Orora Pty Ltd B9 Paper Mill EPL Compliance Quarterly noise monitoring report 20 June 2017 Doc no. 102-QM-RP-4-0 Orora Pty Ltd B9 Paper Mill - EPL Compliance Title Document no. Quarterly noise monitoring
More informationLiddell Coal Operations
Liddell Coal Operations Environmental Noise Monitoring May 2018 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring May 2018 Reference: Report date:
More informationABERDEEN HARBOUR EXPANSION PROJECT November Volume 3: Technical Appendices
ABERDEEN HARBOUR EXPANSION PROJECT November 2015 Volume 3: Technical Appendices Appendix 20-B BASELINE NOISE SURVEY 20-B BASELINE NOISE SURVEY Noise Sensitive Receptors A desk-based study and site walkover
More informationOneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017
OneSteel Recycling Pty Ltd 14-Jul-2017 60493017 OneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017 NATA ACCREDITATION No. 2778 (14391) Accredited for compliance with ISO/IEC 17025 Testing
More informationEnvironment Protection Authority (EPA), Industrial Noise Policy (INP) 2000;
10 October 2017 Suite 6, Level 1,, 146 Hunter Street Newcastle NSW 2300 PO Box 506 Pere Riini Quarry Manager Hanson Construction Materials Pty Ltd Level 5, 75 George Street Parramatta, NSW 2150 Newcastle,
More informationAcoustics Technical Note
Acoustics Technical Note To Ian Roach From Alf Maneylaws Copies to File Date 30/3/11 Subject D123356: Devonport EfW: Analysis of measurement data to support adopted approach to BS4142 assessment. Introduction
More informationSheringham Shoal Cawston, Norfolk. Substation Noise Assessment Summary
Sheringham Shoal Cawston, Norfolk Substation Noise Assessment Summary Document title: Substation Noise Assessment Summary Status: Final Date: 13 March 2015 Project name: Sheringham Shoal, Cawston, Norfolk
More informationJanuary 2012 Noise Impact Assessment Report for Proposed Cable Tow System For Wakeboarding & Water-skiing Grand Canal Dock, Dublin 4
January 2012 Noise Impact Assessment Report for Proposed Cable Tow System For Wakeboarding & Water-skiing Grand Canal Dock, Dublin 4 MALONE O REGAN 2B Richview Office Park, Clonskeagh, Dublin 14. Tel:
More informationAppendix 8. Draft Post Construction Noise Monitoring Protocol
Appendix 8 Draft Post Construction Noise Monitoring Protocol DRAFT CPV Valley Energy Center Prepared for: CPV Valley, LLC 50 Braintree Hill Office Park, Suite 300 Braintree, Massachusetts 02184 Prepared
More informationOrora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 11 August Doc no QM-RP-1-0
Orora Pty Ltd B9 Paper Mill EPL Compliance Quarterly noise monitoring report 11 August 16 Doc no. 102-QM-RP-1-0 Orora Pty Ltd B9 Paper Mill - EPL Compliance Title Document no. Quarterly noise monitoring
More informationAttended Noise Monitoring - Quarter Ending September 2013
Unity Mining Level 10, 350 Collins St Melbourne VIC 3000 Version: Page 2 PREPARED BY: ABN 29 001 584 612 Units 7-8, 26-28 Napier Close Deakin ACT 2600 Australia (PO Box 9344 Deakin ACT 2600 Australia)
More informationBickerdike Allen Partners
25 CHURCH ROAD, SE19 ENTERTAINMENT NOISE ASSESSMENT Report to Kayode Falebita Kingsway International Christian Centre 3 Hancock Road Bromley-By-Bow London E3 3DA A9540/R01-A-HT 26/07/2012 CONTENTS Page
More informationAshton Coal. Environmental Noise Monitoring May Prepared for Ashton Coal Operations Pty Ltd
Ashton Coal Environmental Noise Monitoring May 2018 Prepared for Ashton Coal Operations Pty Ltd Page i Ashton Coal Environmental Noise Monitoring May 2018 Reference: Report date: 5 June 2018 Prepared for
More informationACOUSTIC BARRIER FOR TRANSFORMER NOISE. Ruisen Ming. SVT Engineering Consultants, Leederville, WA 6007, Australia
ICSV14 Cairns Australia 9-12 July, 2007 ACOUSTIC BARRIER FOR TRANSFORMER NOISE Ruisen Ming SVT Engineering Consultants, Leederville, WA 6007, Australia Roy.Ming@svt.com.au Abstract In this paper, an acoustic
More information79 First Avenue Mob: FIVE DOCK NSW 2046 VENTILATED ACOUSTIC ENCLOSURE NOISE EMISSION ASSESSMENT ACOUSTIC SERVICES & ADVICE
Head Office Postal Address T 02 9908 1270 Suite 9 PO Box 270 F 02 9908 1271 38-46 Albany St Neutral Bay 2089 E info@acousticdynamics.com.au St Leonards 2065 ABN: 36 105 797 715 W www.acousticdynamics.com.au
More informationNoise Mitigation Study Pilot Program Summary Report Contract No
Ohio Turnpike Commission Noise Mitigation Study Pilot Program Summary Report Contract No. 71-08-02 Prepared For: Ohio Turnpike Commission 682 Prospect Street Berea, Ohio 44017 Prepared By: November 2009
More informationBoggabri Coal Mine. Environmental Noise Monitoring October Prepared for Boggabri Coal Operations Pty Ltd
Boggabri Coal Mine Environmental Noise Monitoring October 2017 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring October 2017 Reference: Report date:
More informationENVIRONMENTAL NOISE MONITORING QUARTER 1, Northparkes Mines PO Box 995 Parkes NSW 2870
ENVIRONMENTAL NOISE MONITORING QUARTER 1, 2018 s PO Box 995 Parkes NSW 2870 Job No: J38252 Report issued: 25 June 2018 ESP ENVIRONMENTAL & SAFETY PROFESSIONALS A division of Enviro-Net Australia Pty. Ltd.
More informationENVIRONMENTAL NOISE ASSESSMENT
ENVIRONMENTAL NOISE ASSESSMENT AT MURPHY BREWERY. Report Dated: 25 June 15 Greenhills House, Kilmoney, Carrigaline, Co. Cork. Tel: 353 21 437433 http://www.env.ie/ TITLE: Environmental Noise Assessment
More informationWambo Coal Mine and Rail Spur
Wambo Coal Mine and Rail Spur Environmental Noise Monitoring November 2017 Prepared for Wambo Coal Pty Limited Page i Wambo Coal Mine and Rail Spur Environmental Noise Monitoring November 2017 Reference:
More informationStandard Guide for Measurement of Outdoor A-Weighted Sound Levels 1
Designation: E 1014 84 (Reapproved 1995) e1 AMERICAN SOCIETY FOR TESTING AND MATERIALS 100 Barr Harbor Dr., West Conshohocken, PA 19428 Reprinted from the Annual Book of ASTM Standards. Copyright ASTM
More informationUniversity of York Heslington East Campus Details of Noise Modelling and Noise Survey. Report ref AAc/ /R01
Heslington East Campus Details of Noise Modelling and Noise Survey Report ref Heslington East Campus Details of Noise Modelling and Noise Survey January 2008 Arup Acoustics Admiral House, Rose Wharf, 78
More informationNoise Assessment for Planning Purposes - as per TAN11
Noise Assessment for Planning Purposes - as per TAN11 Report No: 1703035R01A Report Status: Final Report (Amended) Dated: 23 October 2017 Purchase order No: n/a Prepared for: Garep Demirci 73 Spencer David
More informationCompliance Noise Survey & Assessment
John Trotter Compliance Noise Survey & Assessment Duralie Coal October 2009 Issued October 2009 Vipac Engineers & Scientists Ltd Hunter Valley / Newcastle, NSW REPORT NO: 29N-09-0002-TRP-470219-0 PREPARED
More informationStatus: Rev: Comments Date: Author: Reviewer:
PAKENHAM EAST PRECINCT STRUCTURE PLAN CITY GATE NOISE ASSESSMENT Rp 002 R03 20171135 28 May 2018 Marshall Day Acoustics Pty Ltd ABN: 53 470 077 191 6 Gipps Street Collingwood VIC 3066 Australia T: +613
More informationMuswellbrook Coal Company
Muswellbrook Coal Company June, 12 Environmental Noise Monitoring Prepared for Muswellbrook Coal Muswellbrook Coal Company June, 12 Environmental Noise Monitoring Reference: Report date: 9 August 12 Prepared
More informationAssessing Entertainment Noise. Using EPA s N-2 Policy (Control of Music Noise from Public Premises)
Assessing Entertainment Noise. Using EPA s N-2 Policy (Control of Music Noise from Public Premises) Noise Limits & Levels for Indoor Venues Indoor Venues 14. The noise limits for indoor venues are: (a)
More informationM Sport Evaluation Centre ( MEC ) Dovenby Hall Estate
M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate Noise Management Plan Date November 2014 Issue No 1 TABLE OF CONTENTS 1. Introduction/Purpose 2. Responsibility and Authority 3. Noise Monitoring 4.
More informationWambo Coal Mine and Rail Spur
Wambo Coal Mine and Rail Spur Environmental Noise Monitoring August 2017 Prepared for Wambo Coal Pty Limited Page i Wambo Coal Mine and Rail Spur Environmental Noise Monitoring August 2017 Reference: Report
More informationCALGA SAND QUARRY ATTENDED COMPLIANCE NOISE MONITORING 12 APRIL 2017 REPORT NO E VERSION A APRIL 2017 PREPARED FOR
ATTENDED COMPLIANCE NOISE MONITORING 12 APRIL 2017 REPORT NO. 01127-E VERSION A APRIL 2017 PREPARED FOR HANSON CONSTRUCTION MATERIALS PTY LTD LOT 151 PEATS RIDGE ROAD CALGA NSW 2250 DOCUMENT CONTROL Version
More informationSouthwest Anthony Henday Drive At Wedgewood Heights Residential Neighborhood in Edmonton, AB
aci Acoustical Consultants Inc. 5031-210 Street Edmonton, Alberta, Canada T6M 0A8 Phone: (780) 414-6373 www.aciacoustical.com Environmental Noise Study For Southwest Anthony Henday Drive At Wedgewood Heights
More informationNoise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex
Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex Report ref. PJ3159/13181 Date August 13 Issued to Cuadrilla Resources Limited Issued by Peter Jackson MSc MIOA
More informationLiddell Coal Operations
Liddell Coal Operations Environmental Noise Monitoring April 2016 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring April 2016 Reference: Report
More informationCullen Valley Mine. Environmental Noise Monitoring Quarter 2, Prepared for Castlereagh Coal
Cullen Valley Mine Environmental Noise Monitoring Quarter 2, 2018 Prepared for Castlereagh Coal Page i Cullen Valley Mine Environmental Noise Monitoring Quarter 2, 2018 Reference: Report date: 28 June
More informationEnvironmental Noise Measurement Kits
SOUND LEVEL METERS dosebadge 5 NOISE DOSEMETER SAFETY OFFICER S NOISE KITS ENVIRONMENTAL NOISE MEASUREMENT KITS ENVIRONMENTAL NOISE MONITORS Environmental Noise Measurement Kits The latest environmental
More informationRev2-18.Feb Safety Reliability Integrity Training Asset Support Design Support Troubleshooting
KEYSBROOK ENVIRONMENTAL NOISE COMPLIANCE REPORTING Q1 2016 MZI RESOURCES LTD 1370900-5-100-Rev2-18.Feb.2016 www.svt.com.au Perth Brisbane Kuala Lumpur Bangkok Noise Vibration Corrosion Safety Reliability
More informationPipeline Blowdown Noise Levels
Pipeline Blowdown Noise Levels James Boland 1, Henrik Malker 2, Benjamin Hinze 3 1 SLR Consulting, Acoustics and Vibration, Brisbane, Australia 2 Atkins Global, Acoustics, London, United Kingdom 3 SLR
More information91 Street Earth Berm Removal in Edmonton, Alberta
aci Acoustical Consultants Inc. 5031-210 Street Edmonton, Alberta, Canada T6M 0A8 Phone: (780) 414-6373 www.aciacoustical.com Environmental Noise Monitoring For The 91 Street Earth Berm Removal in Edmonton,
More informationREPORT OF NOISE MONITORING OF TUTUR1C SID TRIAL AT EDINBURGH AIRPORT AUGUST TO NOVEMBER 2015 SITE 2: UPHALL
Date: 09 March 2016 REPORT OF NOISE MONITORING OF TUTUR1C SID TRIAL AT EDINBURGH AIRPORT AUGUST TO NOVEMBER 2015 SITE 2: UPHALL Client: Edinburgh Limited Report Author:... Dr R. Peters Principal Consultant
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 1996-2 Second edition 2007-03-15 Acoustics Description, measurement and assessment of environmental noise Part 2: Determination of environmental noise levels Acoustique Description,
More informationWambo Coal Mine and Rail Spur
Wambo Coal Mine and Rail Spur Environmental Noise Monitoring September 2017 Prepared for Wambo Coal Pty Limited Page i Wambo Coal Mine and Rail Spur Environmental Noise Monitoring September 2017 Reference:
More informationBoggabri Coal Mine. Environmental Noise Monitoring August Prepared for Boggabri Coal Operations Pty Ltd
Boggabri Coal Mine Environmental Noise Monitoring August 2018 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring August 2018 Reference: Report date:
More informationRaging River Quarry. Environmental Noise Monitoring Protocol Provisional Operations 11/30/2016
Raging River Quarry Environmental Noise Monitoring Protocol Provisional Operations 11/30/2016 Introduction The Raging River Quarry operates in unincorporated King County, near Fall City, Washington. King
More informationBoggabri Coal Mine. Environmental Noise Monitoring June Prepared for Boggabri Coal Operations Pty Ltd
Boggabri Coal Mine Environmental Noise Monitoring June 2017 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring June 2017 Reference: Report date: 5 July
More information# Insite RE Inc./ Verizon Wireless Special Use Permit Project Review for Planning and Zoning Commission
#2015-52 Insite RE Inc./ Verizon Wireless Special Use Permit Project Review for Planning and Zoning Commission Meeting Date: October 21, 2015 Request: Location: A Special Use Permit for a wireless communication
More informationR e p o r t th A u g u s t
N o ise Mon it o r ing R e p o r t L e g a c y W a y T u n n e l M o n i t o r i n g P o s t C o m m is s i o n ing T es ts V e n ti la t ion S t a c ks Jun e 20 1 6 R e p o r t 3557 4 th A u g u s t 2
More informationSwan DH Noise Impact Assessment Report
Swan 4-64 6-1 3DH Noise Impact Assessment Report April 9, 2018 Prepared for: ConocoPhillips 34501 East Quincy Avenue Watkins, Colorado 80137 Prepared by: Behrens and Associates, Inc. 13806 Inglewood Avenue
More informationRoof top of Ash Lagoon decantrate pump house Existing Ching Lam noise monitoring station
3. NOISE 3.1 Monitoring Requirements According to the requirements in the Construction EM&A Manual for Lamma Extension, the baseline levels at the monitoring locations have to be determined prior to the
More informationBlack Butte Copper Project Mine Operating Permit Application (Revision 3)
Mine Operating Permit Application (Revision 3) APPENDIX J: Tintina Montana, Inc. July 17 MEMORANDUM DATE: October 7, 13 TO: FROM: RE: Allan Kirk / Geomin Resources Bob Jacko / Tintina Resources Sean Connolly
More informationKeystone Pipeline Phases 1 & 2 Acoustic Monitoring Report for Canadian Pump Stations
Revision 0 Keystone Project Document # RE-03 [2-4-22-2] ATCO Project # 763000 TransCanada Pipeline Ltd. Keystone Pipeline Project Keystone Pipeline Phases 1 & 2 Acoustic Monitoring Report for Canadian
More informationProject Survey Report Plotting of Noise Isopleth Maps of Robinson Lake Natural Gas Plant
HAGEMEYER NORTH AMERICA - Technical Services. 6825 West Sam Houston Parkway North, Houston, Texas 77041 OFFICE 713.896.0193 FAX 713.896.6006 WWW.HAGEMEYERNA.COM April 2 nd, 2013 Mr. Justin Clock Health
More informationTechnical Note. Noise reducing properties of crash barriers. Performed for WillumTech. AV 1217/11 Project no.: A Page 1 of 19 incl.
Technical Note Noise reducing properties of crash barriers Performed for WillumTech Project no.: A581500 Page 1 of 19 incl. 1 annex 6 October 2011 DELTA Venlighedsvej 4 2970 Hørsholm Denmark Tel. +45 72
More informationCymbaluk Noise Complaints
Decision 20259-D01-2015 Cymbaluk Noise Complaints December 22, 2015 Alberta Utilities Commission Decision 20259-D01-2015 Cymbaluk Noise Complaints Proceeding 20259 Application 20259-A001 December 22, 2015
More informationStatement of Evidence of N I Hegley
IN THE MATTER AND IN THE MATTER of the Resource Management Act 1991 of Notices of Requirement to enable the construction, operation and maintenance of the City Rail Link. Statement of Evidence of N I Hegley
More informationInformations and comments on ECE-TRANS-WP.29-GRB e
Transmitted by the expert from France Informal document GRB-63-16 (63rd GRB, 16-18 February 2016, agenda item 2) Informations and comments on ECE-TRANS-WP.29-GRB-2016-02e Louis-Ferdinand PARDO (France)
More informationLion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC. Final Report Rev 1
Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC Final Report Rev 1 Noise Impact Assessment RWDI # 1502274 SUBMITTED TO Paul Dufault Project Manager Metro Vancouver 4330
More informationM Sport Evaluation Centre ( MEC ) Dovenby Hall Estate
M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate Noise Management Plan Date 31/7/15 Issue No 2e DRAFT TABLE OF CONTENTS 1. Policy Statement 2. Introduction/Purpose 3. Responsibility and Authority
More informationMackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014
Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014 Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014 Prepared by Umwelt (Australia) Pty Limited on behalf of Mackas Sand Pty Ltd
More informationFundamentals of Environmental Noise Monitoring CENAC
Fundamentals of Environmental Noise Monitoring CENAC Dr. Colin Novak Akoustik Engineering Limited April 03, 2013 Akoustik Engineering Limited Akoustik Engineering Limited is the sales and technical representative
More informationCR:247 Invictus. Portable Noise Monitor. Features. Features. Applications
Key Features High performance portable noise monitor Purpose designed for outdoor noise measurement applications Simultaneous measurement of all parameters 120dB measurement range in a single span Colour
More informationAssessment of rail noise based on generic shape of the pass-by time history
Proceedings of Acoustics 23 Victor Harbor 7-2 November 23, Victor Harbor, Australia Assessment of rail noise based on generic shape of the pass-by time history Valeri V. enchine, Jonathan Song Science
More informationMemorandum 1.0 Highway Traffic Noise
Memorandum Date: September 18, 2009 To: Chris Hiniker, SEH From: Stephen B. Platisha, P.E. Re: Updated CSAH 14 Noise Analysis The purpose of this memorandum is to provide the results of the revised traffic
More informationTemplate Planning Condition on Amplitude Modulation Noise Guidance Notes
www.renewableuk.com Template Planning Condition on Amplitude Modulation Noise Guidance Notes December 2013 Template Planning Condition on Amplitude Noise Guidance Notes Modulation Introduction Introduction
More informationProtocol for Ambient Level Noise Monitoring
July 2015 Protocol for Ambient Level Noise Monitoring L pressure =10.log [10 (Lp/10) - 10 (LpBackground/10) ] L pressure = 10.log [10 (Lp/10) - 10 (LpBackground/10) ] CENTRAL POLLUTION CONTROL BOARD P
More informationNETWORK RAIL BORDERS RAILWAY OPERATIONAL NOISE AND VIBRATION (YEAR 1, ROUND 2) REP-003. September 2016
Ref:15375 OPERATIONAL NOISE AND VIBRATION (YEAR 1, ROUND 2) 15375-REP-003 September 2016 Registered Office Park House 39 Bo ness Road Grangemouth Stirlingshire FK3 8AN Tel: +44 (0)1324 878822 Fax: +44
More informationMethods for rating and assessing industrial and commercial sound
BS 4142:2014 BSI Standards Publication Methods for rating and assessing industrial and commercial sound BS 4142:2014 BRITISH STANDARD Publishing and copyright information The BSI copyright notice displayed
More informationNoise Monitoring Program
for Document Table of Contents for... 1 1 Purpose... 3 1.1 Purpose... 3 2 Noise Impact Assessment Criteria... 3 2.1 Noise Criteria... 3 3 Measurement and Evaluation... 6 3.1 Monitoring Locations... 6 3.2
More informationAssessing the accuracy of directional real-time noise monitoring systems
Proceedings of ACOUSTICS 2016 9-11 November 2016, Brisbane, Australia Assessing the accuracy of directional real-time noise monitoring systems Jesse Tribby 1 1 Global Acoustics Pty Ltd, Thornton, NSW,
More informationCity of Hamilton INFORMATION FOR CONDITIONAL USE PERMIT
City of Hamilton INFORMATION FOR CONDITIONAL USE PERMIT There is a $200.00 non-refundable fee for each request. Requests must be completed and submitted to the Public Works Department, City of Hamilton,
More informationAppendix G Noise and Vibration Assessment
Appendix G Noise and Vibration Assessment Annex G1: Noise Perception and Terminology Annex G2: Baseline Noise Monitoring Annex G3: Construction Information Annex G4: Operational Information Annex G1: Noise
More informationAPPENDIX F BASELINE NOISE REPORT
APPENDIX F BASELINE NOISE REPORT APPENDIX F BASELINE NOISE REPORT F BASELINE NOISE REPORT Contents Summary A Baseline Noise Report was prepared for Damhead Creek 2. This is presented in this Appendix
More informationAppendix D: Preliminary Noise Evaluation
Appendix D: Preliminary Noise Evaluation Acoustics The study of sound and its properties is known as acoustics. By considering basic physical properties of sound and the acoustic environment, the potential
More information1 Dockland Central, Guild St, Dublin 1 1 Lárcheantar na ndugaí, Sráid na ngildeanna, BÁC 1 Tel Teil
An Coimisiún um Rialáil Cumarsáide 1 Dockland Central, Guild St, Dublin 1 1 Lárcheantar na ndugaí, Sráid na ngildeanna, BÁC 1 Tel Teil +353 1 804 9600 www.comreg.ie Programme of Measurement of Non-Ionising
More information