1 Mullingar Business Park, Mullingar, Co Westmeath. Annual Noise Report 2013 Licence Number: W Report Date: 09 th July 2013 Report Number: Version 0 AXIS environmental services 40 Coolraine Heights, Old Cratloe Road, Limerick Tel (061) Mobile(087) info@axisenv.ie

2 Report Content 1.0 Executive Summary Introduction Methods Employed Monitoring Locations Daytime Noise Measurements Conclusions. 12 Report No: Page 2 of 19 Version 0

3 1.0 Executive Summary are required as part of licence W : to carry out a noise survey at the installation on an annual basis. The noise monitoring positions have been located at site boundaries and in close proximity to other industrial and office units. AXIS environmental services were commissioned to carry out the survey after proposal acknowledgment and acceptance by s Environmental Department. For consistency in reporting, and the Agency have agreed noise monitoring locations at the installation. The same locations will be used for each monitoring round, unless circumstances prevent an accurate survey been carried out. In this event, Soltec (Ireland) Limited will agree new monitoring points with the Agency prior to the change. Four monitoring points were located within the boundary of the site. There were five points monitored in total during the survey period for broadband and one third octave frequency analyses. is located in Zone A, Mullingar Business Park, Mullingar, Co Westmeath. The surrounding facilities include a tyre centre, Eircom & general industrial warehouses & factories. There is a railway line at the rear of the property. The estate is quite busy with traffic and activities on-going at alternative industries in the vicinity. All operations in Soltec continued as normal during the day time survey survey. Report No: Page 3 of 19 Version 0

4 2.0 Introduction As part of compliance monitoring at, noise monitoring is carried out at a number of boundary locations and one off site monitoring point in the vicinity of the installation. Condition 8 of the Waste Licence W outlines the following requirements: 8.6. Noise monitoring The location of the noise monitoring points shall be as per Attachment J.7 of the application. Noise Monitoring Locations Location Note 1 Measurement Note 2 Frequency N1 North West Corner N2 South East Boundary N3 South West Boundary N4 North East Corner N5 Southern Boundary L Aeq 30 minutes L Aeq 30 minutes L Aeq 30 minutes L Aeq 30 minutes L Aeq 30 minutes Annual Annual Annual Annual Annual Note 1: Or at any other locations specified by the Agency. Note 2: International Standards Organisation. ISO Acoustics - description and Measurement of Environmental noise. Parts 1, 2 and 3. Report No: Page 4 of 19 Version 0

5 3.0 Methods Monitoring was carried out in strict accordance with ISO 1996 Parts 1 3, Description and Measurement of Environmental Noise. Reference was also made to the EPA guidelines NG4 Guidance Note for Noise: Licence Applications, Surveys and Assessments in Relation to Scheduled Activities April 2012, in conjunction with the frequently asked questions issued by the Agency in August Table 2: Equipment Details Meter No 2 Meter No 3 Manufacturer Cirrus Optimus Green Cirrus Optimus Green Model CR:171B CR:172B Serial Number G G Firmware V V Calibrator CR:515 Acoustic Calibrator CR:515 Acoustic Calibrator Microphone B&K B&K Windshield Type UA:237 90mm Foam Windshield UA:237 90mm Foam Windshield Calibration Date Noise Meter 18 th Nov nd Aug Certificate Number Calibrator 18 th Nov th Nov Certificate Number On site SLM calibration Prior to Survey Calibration Offset Post Survey Frequency Weighting A - Broadband A - Broadband Meter Response Time Fast Fast Report No: Page 5 of 19 Version 0

6 4.0 Monitoring Locations 4.1 N1 This monitoring point was located in the North western corner of the site. This position is located between activities on site and the nearest noise sensitive location to the north east. The main sources of noise noted at this point were as follows: Background traffic in Mullingar Business Park i.e. Forklifts reversing, loud truck engines Birds chirping in surrounding vegetation Noise from air extraction unit on site approx 25m from monitoring point. Humming Noise from Industrial cooling unit at side of building approx 35m from monitoring point. Nearby heavy gate being unlocked and opened by employee approx 5m from monitoring point. 4.2 N2 This monitoring point was located at the south eastern corner of the site. This position is located between the Eircom car park entrance gate and the car park. The main sources of noise noted during the survey include the following: 4.3 N3 Truck reversing at nearby tyre shop (Mileage Tyres) approx 50m from monitoring point Birds chirping in surrounding vegetation. Person talking on phone in Eircom carpark approx 10m from monitoring point. Car entering Eircom car park. Backgournd traffic in the estate. Train movement on the train line behind Soltec. This monitoring point was located on the south western boundary of the installation between Soltec and the Eircom building. The main sources of noise recorded include the following: Birds chirping in nearby vegetation Background Traffic in Mullingar Business Park i.e. Forklift driving/reversing in Eircom. People chatting both in Soltec building and outside of building. Humming noise from industrial cooling unit at side of Soltec building approx 25m from monitoring point. Eircom s gates opening and closing. Report No: Page 6 of 19 Version 0

7 4.4 N4 The monitoring point was located to the north eastern corner of the site behind Sally s Salon Supplies in a semi-enclosed area. The main sources of noise recorded include the following: Birds chirping in the nearby vegetation Heavy gate at front of the site opening and closing; Train going by approx 20m from monitoring point Forklift loading truck and people talking Background noise in the industrial estate 4.5 N5 The monitoring point was located to the south of the site directly in front of the Eircom building. The noise meter was positioned between the Eircom boundary fencing and a road directly in front of Soltec (Ireland) limited. There was a range of noise sources recorded at this point. Traffic entering and leaving Eircom car park Engine left running idle Background Traffic in Mullingar Business Park Noise from truck engine and forklift as truck is being loaded approx 10m from monitoring point. Air-gun operating in nearby tyre shop (Mileage Tyres) approx 60m from monitoring point. Report No: Page 7 of 19 Version 0

8 5.0 Summary of Daytime Noise Measurements Noise Monitoring Location: N1 (Boundary Monitoring Point) Measured Noise Levels (db re. 2 x 10-5 Pa) Comments Period: Time L Aeq L AFMAX L A90 Daytime: 12: Arithmetic Average (db): Daytime Criterion, db L Ar,T: Evening: Evening Criterion, db L Ar,T: Night Time: Night time Criterion, db L Ar,T: Main noise sources include background traffic in Mullingar Business Park, Forklift operating in the yard, Birds chirping in surrounding vegetation, Noise from air extraction unit on site, Humming noise from industrial cooling unit and Nearby heavy gate being unlocked and opened by employee approx 5m from monitoring point. the evening period. The site is not defined as a new or revised licence since the guidelines were issued in the night time period. Weather Conditions: Daytime: Evening: Night Time: Temperature ( O C) Wind Speed (m/s) Wind Direction: Wind from NW - - Precipitation: 0mm - - Tonal Noise Assessment Daytime: Run 1: None - - Night Time: Compliance Status this is not a noise sensitive location therefore limits would not apply - Noise from Soltec would be more representative by use of the L A90 Report No: Page 8 of 19 Version 0

9 Noise Monitoring Location: N2 (Boundary Monitoring Point) Measured Noise Levels (db re. 2 x 10-5 Pa) Comments Period: Time L Aeq L AFMAX L A90 10: Daytime: Arithmetic Average (db): Daytime Criterion, db L Ar,T: Evening: Evening Criterion, db L Ar,T: Night Time: Night time Criterion, db L Ar,T: Weather Conditions: The main source of noise included: Tarffic movements from Eircom, air gun from the tyre fitters. An engine was left running close by. Person talking on phone in Eircom car park approx. 10m from monitoring point. Car entering Eircom car park. Background traffic in the estate. Train movement on the train line behind Soltec. the evening period. The site is not defined as a new or revised licence since the guidelines were issued in the night time period. Daytime: Evening: Night Time: Temperature ( O C) Wind Speed (m/s) Wind Direction: Wind from NW - - Precipitation: 0mm - - Tonal Noise Assessment Daytime: Run 1: None - - Night Time: Compliance Status this is not a noise sensitive location therefore limits would not apply - Noise from Soltec would be more representative by use of the L A90 Report No: Page 9 of 19 Version 0

10 Noise Monitoring Location: N3 (Boundary Monitoring Point) Measured Noise Levels (db re. 2 x 10-5 Pa) Comments Period: Time L Aeq L AFMAX L A90 14: Daytime: Arithmetic Average (db): The main source of noise during the survey was from an engine running idle in an adjacent facility. There was also noise from background traffic in the estate and birds continuously chirping. The ESB gate was opened and closed on several occasions during the survey. Daytime Criterion, db L Ar,T: Evening: Evening Criterion, db L Ar,T: Night Time: Night time Criterion, db L Ar,T: Weather Conditions: the evening period. The site is not defined as a new or revised licence since the guidelines were issued in the night time period. Daytime: Evening: Night Time: Temperature ( O C) Wind Speed (m/s) Wind Direction: Wind from NW - - Precipitation: 0mm - - Tonal Noise Assessment Daytime: Run 1: None - - Night Time: Compliance Status this is not a noise sensitive location therefore limits would not apply - the truck next door made representative monitoring at this location impossible on the day. Report No: Page 10 of 19 Version 0

11 Noise Monitoring Location: N4 (Boundary Monitoring Point) Measured Noise Levels (db re. 2 x 10-5 Pa) Comments Period: Time Daytime: L Aeq L AFMAX L A90 13: The main source of noise during the survey was background traffic in the estate and birds continuously chirping. Arithmetic Average (db): Daytime Criterion, db L Ar,T: Evening: Evening Criterion, db L Ar,T: Night Time: Night time Criterion, db L Ar,T: the evening period. The site is not defined as a new or revised licence since the guidelines were issued in the night time period. Weather Conditions: Daytime: Evening: Night Time: Temperature ( O C) Wind Speed (m/s) Wind Direction: Wind from NW - - Precipitation: 0mm - - Tonal Noise Assessment Daytime: Run 1: None - - Night Time: Compliance Status this is not a noise sensitive location therefore limits would not apply Noise from Soltec would be more representative by use of the L A90 Report No: Page 11 of 19 Version 0

12 Noise Monitoring Location: N5 (Boundary Monitoring Point) Measured Noise Levels (db re. 2 x 10-5 Pa) Comments Period: Time L Aeq L AFMAX L A90 14: Daytime: Arithmetic Average (db): This monitoring point was located in front of the eircom offices and yard. The main sources of noise were traffic associated with Eircom and HGV movement to and from their yard. There was a delivery to Eircom which had left the engine running throughout the survey. Daytime Criterion, db L Ar,T: Evening: Evening Criterion, db L Ar,T: Night Time: Night time Criterion, db L Ar,T: Weather Conditions: the evening period. The site is not defined as a new or revised licence since the guidelines were issued in the night time period. Daytime: Evening: Night Time: Temperature ( O C) Wind Speed (m/s) Wind Direction: Wind from NW - - Precipitation: 0mm - - Tonal Noise Assessment Daytime: Run 1: None - - Night Time: Compliance Status this is not a noise sensitive location therefore limits would not apply Report No: Page 12 of 19 Version 0

13 6.0 Conclusions Five points were monitored at Soltec Ireland Ltd as part of their Annual Environmental Survey in accordance with Condition 8 of their Waste License W There was a significant volume of noise being produced from adjacent yards and industries throughout the day. This noise was not in any way associated with activities on-going at Soltec. Monitoring points N3 and N5 were most notably impacted by this external noise sources. During lulls in this interference noise from Soltec would have been well within the licence requirement of 55dB(A). All locations survey would not be considered noise sensitive locations by definition in the EPA guidance note. Soltec is located in the middle of a busy industrial estate with continuous noise sources from other sites. Soltec was therefore considered to be in compliance with licence conditions as there was no impulsive or tonal noise produced on site. When interference noise was quietened, the noise levels from Soltec were well within licence requirements. The actual noise from Soltec would be better described by the L A90 from N1 to N4. Report No: Page 13 of 19 Version 0

14 Appendix I Report No: Page 14 of 19 Version 0

15 Report No: Page 15 of 19 Version 0

16 Report No: Page 16 of 19 Version 0

17 Report No: Page 17 of 19 Version 0

18 Report No: Page 18 of 19 Version 0

19 Appendix II Location Map Report No: Page 19 of 19 Version 0

Xtratherm Limited Kells Road, Navan, Co Meath

Xtratherm Limited Kells Road, Navan, Co Meath Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre Ennis Road Limerick Kells Road, Navan, Co Meath Annual Environmental Noise Survey 2017 IPPC Licence

More information

Rehab Glassco. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only.

Rehab Glassco. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only. Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre, Ennis Road, Limerick Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare Environmental

More information

Glassco Recycling. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only.

Glassco Recycling. Unit 4, Osberstown Industrial Park, Caragh Road, Naas, Co. Kildare. For inspection purposes only. Air I Noise I Water I Soil I Environmental Consultancy www.axisenv.ie Unit 5 Caherdavin Business Centre, Ennis Road, Limerick. info@axisenv.ie 00353 61 324587 Unit 4, Osberstown Industrial Park, Caragh

More information

Offaly County Council

Offaly County Council Derryclure Landfill Facility, Derryclure, Co. Offaly Annual Monitoring Report Waste Licence Reg. No. W0029-04 Report Date: th October 15 Fitz Scientific Unit 35A, Boyne Business Park, Drogheda, Co. Louth

More information

Roche Ireland Limited

Roche Ireland Limited Limited Clarecastle, Co. Clare Monitoring Report Industrial Emissions Licence Number P0012-05 Report Date: 1 st February 17 Fitz Scientific Unit 35A, Boyne Business Park, Drogheda, Co. Louth Report No.

More information

Roche Ireland Limited

Roche Ireland Limited Roche Ireland Limited Clarecastle, Co. Clare Environmental Noise Monitoring Report Industrial Emissions Licence Number P0012-05 Report Date: 6 th October 17 Fitz Scientific Unit 35A, Boyne Business Park,

More information

McGill Environmental Ltd.

McGill Environmental Ltd. McGill Environmental Ltd. Coom, Glenville, Co. Cork Environmental Noise Survey Report Date: 7 th October 2016 For inspection purposes only. KD Environmental Ltd. 1 Swiftbrook Glen, Virginia, Co. Cavan

More information

NOISE IMPACT ASSESSMENT 2016

NOISE IMPACT ASSESSMENT 2016 Panther Environmental Solutions Ltd, Unit 4, Innovation Centre, Institute of Technology, Green Road, Carlow, Ireland. Mobile: 087-8519284 Telephone /Fax: 059-9134222 Email: info@pantherwms.com Website:

More information

W For inspection purposes only. This report shall not be reproduced except in full, without the approval of BnM Environmental.

W For inspection purposes only. This report shall not be reproduced except in full, without the approval of BnM Environmental. ANNUAL MONITORING OF ENVIRONMENTAL NOISE AT THE BORD NA MóNA KILBERRY COMPOST FACILITY IN COMPLIANCE WITH IED LICENCE, NO. W0198-01 For the Attention of: Site Work & Report Prepared by: Anua File Ref:

More information

Pfizer Ireland Pharmaceuticals

Pfizer Ireland Pharmaceuticals Allegro Acoustics Limited, Unit 2A Riverside, Tallaght Business Park, Tallaght, Dublin 24 Tel/Fax: +33 () 1 4148 Pfizer Ireland Pharmaceuticals Pfizer Grange Castle, Grange Castle Business Park, Clondalkin,

More information

REPORT PERIOD: JANUARY 01 MARCH

REPORT PERIOD: JANUARY 01 MARCH QUARTERLY NOISE MONITORING REPORT FOR EAST GALWAY LANDFILL REPORT PERIOD: JANUARY 01 MARCH 31 2018 IE LICENCE REF. NO. W0178-02 APRIL 2018 QUARTERLY NOISE MONITORING REPORT FOR EAST GALWAY LANDFILL REPORT

More information

TECHNICAL REPORT 2016 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK.

TECHNICAL REPORT 2016 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK. TECHNICAL REPORT 16 IEL ENVIRONMENTAL NOISE SURVEY OF THE DAIRYGOLD CASTLEFARM FACILITY, MITCHELSTOWN, CO. CORK. FOR Gabriel Kelly Group Environmental Manager Dairygold Food ingredients Castlefarm Mitchelstown

More information

BASELINE NOISE MONITORING SURVEY

BASELINE NOISE MONITORING SURVEY t m s environment ltd TMS Environment Ltd 53 Broomhill Drive Tallaght Dublin 24 Phone: +353-1-4626710 Fax: +353-1-4626714 Web: www.tmsenv.ie BASELINE NOISE MONITORING SURVEY UNIVERSITY COLLEGE DUBLIN Report

More information

Noise Monitoring Report For. Schloetter (Ireland) Ltd. Naas Enterprise Park, Naas, Co. Kildare

Noise Monitoring Report For. Schloetter (Ireland) Ltd. Naas Enterprise Park, Naas, Co. Kildare Bray (Co. Wicklow) 01 276 1428 Lisburn (Co. Antrim) 028 9262 6733 Birmingham (U.K.) 0121 673 1804 Blackrock (Co.Cork) 021 4536155 Noise Monitoring Report 2017 For Schloetter (Ireland) Ltd. Naas Enterprise

More information

CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017.

CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017. CENTRAL WASTE MANAGEMENT FACILITY, INAGH, CO. CLARE. ENVIRONMENTAL NOISE MONITORING MAY 2017. Prepared for: CLARE COUNTY COUNCIL ÁRAS CONTAE AN CHLÁIR NEW ROAD ENNIS CO. CLARE 3156 May 16 th, 2017 EPA

More information

MALONE O REGAN. Annual Noise Survey Powerstown Landfill Industrial Emission Licence No. W March 2016

MALONE O REGAN. Annual Noise Survey Powerstown Landfill Industrial Emission Licence No. W March 2016 MALONE O REGAN March 2016 Powerstown Landfill Industrial Emission Licence No. W0025-04 Annual Noise Survey 2015 2B Richview Office Park, Clonskeagh, Dublin 14. Tel: +353 01 2602655 Fax: +353 01 2602660

More information

Muswellbrook Coal Company

Muswellbrook Coal Company Muswellbrook Coal Company Environmental Noise Monitoring November 2015 Prepared for Muswellbrook Coal Page i Muswellbrook Coal Company Environmental Noise Monitoring November 2015 Reference: Report date:

More information

Quarterly Noise Monitoring Report Austar Coal Mine Middle Road, Paxton NSW January 2007

Quarterly Noise Monitoring Report Austar Coal Mine Middle Road, Paxton NSW January 2007 REPORT 30-1664R1R0 Quarterly Noise Monitoring Report Austar Coal Mine Middle Road, Paxton NSW January 2007 PREPARED FOR P.O Box 806 Cessnock NSW 2325 14 MAY 2007 Quarterly Noise Monitoring Report Austar

More information

Electricity Supply to Africa and Developing Economies. Challenges and opportunities. Planning for the future in uncertain times

Electricity Supply to Africa and Developing Economies. Challenges and opportunities. Planning for the future in uncertain times Electricity Supply to Africa and Developing Economies. Challenges and opportunities. Planning for the future in uncertain times 765 kv Substation Acoustic Noise Impact Study by Predictive Software and

More information

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000;

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000; 15 December 2017 Suite 6, Level 1, 146 Hunter Street Newcastle NSW 2300 PO Box 506 Pere Riini Quarry Manager Hanson Construction Materials Pty Ltd Level 5, 75 George Street Parramatta, NSW 2150 Newcastle,

More information

Muswellbrook Coal Company

Muswellbrook Coal Company Muswellbrook Coal Company Environmental ise Monitoring May 2015 Prepared for Muswellbrook Coal Page i Muswellbrook Coal Company Environmental ise Monitoring May 2015 Reference: Report date: 18 June 2015

More information

Attended Noise Monitoring Program

Attended Noise Monitoring Program 1 November 2018 Ref: 171356/8121 Muswellbrook Coal Company PO Box 123 Muswellbrook NSW 2333 RE: OCTOBER 2018 NOISE MONITORING RESULTS MUSWELLBROOK COAL MINE This letter report presents the results of noise

More information

Review of Baseline Noise Monitoring results and Establishment of Noise Criteria

Review of Baseline Noise Monitoring results and Establishment of Noise Criteria Appendix G Review of Baseline Noise Monitoring results and Establishment of Noise Criteria Environmental Management Plan G May 2014 Colton Coal Mine Aldershot, Queensland Review of Baseline Noise Monitoring

More information

Attended Noise Monitoring Program

Attended Noise Monitoring Program 16 May 2018 Ref: 171356/7853 Muswellbrook Coal Company PO Box 123 Muswellbrook NSW 2333 RE: MAY 2018 NOISE MONITORING RESULTS MUSWELLBROOK COAL MINE This letter report presents the results of noise compliance

More information

Black. LWECS Site Permit. Stearns County. Permit Section:

Black. LWECS Site Permit. Stearns County. Permit Section: PERMIT COMPLIANCE FILING Permittee: Permit Type: Project Location: Docket No: Permit Section: Date of Submission : Black Oak Wind,, LLC LWECS Site Permit Stearns County IP6853/WS-10-1240 and IP6866/WS-11-831

More information

ITV CORONATION STREET PRODUCTION FACILITY, TRAFFORD WHARF ROAD ASSESSMENT OF POTENTIAL NOISE & VIBRATION IMPACT OF PROPOSED METROLINK LINE

ITV CORONATION STREET PRODUCTION FACILITY, TRAFFORD WHARF ROAD ASSESSMENT OF POTENTIAL NOISE & VIBRATION IMPACT OF PROPOSED METROLINK LINE ITV CORONATION STREET PRODUCTION FACILITY, TRAFFORD WHARF ROAD ASSESSMENT OF POTENTIAL NOISE & VIBRATION IMPACT OF PROPOSED METROLINK LINE On behalf of: ITV plc Report No. 22396.01v1 October 2014 ITV CORONATION

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring February 2018 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring February 2018 Reference:

More information

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 20 June Doc no QM-RP-4-0

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 20 June Doc no QM-RP-4-0 Orora Pty Ltd B9 Paper Mill EPL Compliance Quarterly noise monitoring report 20 June 2017 Doc no. 102-QM-RP-4-0 Orora Pty Ltd B9 Paper Mill - EPL Compliance Title Document no. Quarterly noise monitoring

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring May 2018 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring May 2018 Reference: Report date:

More information

ABERDEEN HARBOUR EXPANSION PROJECT November Volume 3: Technical Appendices

ABERDEEN HARBOUR EXPANSION PROJECT November Volume 3: Technical Appendices ABERDEEN HARBOUR EXPANSION PROJECT November 2015 Volume 3: Technical Appendices Appendix 20-B BASELINE NOISE SURVEY 20-B BASELINE NOISE SURVEY Noise Sensitive Receptors A desk-based study and site walkover

More information

OneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017

OneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017 OneSteel Recycling Pty Ltd 14-Jul-2017 60493017 OneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017 NATA ACCREDITATION No. 2778 (14391) Accredited for compliance with ISO/IEC 17025 Testing

More information

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000;

Environment Protection Authority (EPA), Industrial Noise Policy (INP) 2000; 10 October 2017 Suite 6, Level 1,, 146 Hunter Street Newcastle NSW 2300 PO Box 506 Pere Riini Quarry Manager Hanson Construction Materials Pty Ltd Level 5, 75 George Street Parramatta, NSW 2150 Newcastle,

More information

Acoustics Technical Note

Acoustics Technical Note Acoustics Technical Note To Ian Roach From Alf Maneylaws Copies to File Date 30/3/11 Subject D123356: Devonport EfW: Analysis of measurement data to support adopted approach to BS4142 assessment. Introduction

More information

Sheringham Shoal Cawston, Norfolk. Substation Noise Assessment Summary

Sheringham Shoal Cawston, Norfolk. Substation Noise Assessment Summary Sheringham Shoal Cawston, Norfolk Substation Noise Assessment Summary Document title: Substation Noise Assessment Summary Status: Final Date: 13 March 2015 Project name: Sheringham Shoal, Cawston, Norfolk

More information

January 2012 Noise Impact Assessment Report for Proposed Cable Tow System For Wakeboarding & Water-skiing Grand Canal Dock, Dublin 4

January 2012 Noise Impact Assessment Report for Proposed Cable Tow System For Wakeboarding & Water-skiing Grand Canal Dock, Dublin 4 January 2012 Noise Impact Assessment Report for Proposed Cable Tow System For Wakeboarding & Water-skiing Grand Canal Dock, Dublin 4 MALONE O REGAN 2B Richview Office Park, Clonskeagh, Dublin 14. Tel:

More information

Appendix 8. Draft Post Construction Noise Monitoring Protocol

Appendix 8. Draft Post Construction Noise Monitoring Protocol Appendix 8 Draft Post Construction Noise Monitoring Protocol DRAFT CPV Valley Energy Center Prepared for: CPV Valley, LLC 50 Braintree Hill Office Park, Suite 300 Braintree, Massachusetts 02184 Prepared

More information

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 11 August Doc no QM-RP-1-0

Orora Pty Ltd. B9 Paper Mill EPL Compliance Quarterly noise monitoring report. 11 August Doc no QM-RP-1-0 Orora Pty Ltd B9 Paper Mill EPL Compliance Quarterly noise monitoring report 11 August 16 Doc no. 102-QM-RP-1-0 Orora Pty Ltd B9 Paper Mill - EPL Compliance Title Document no. Quarterly noise monitoring

More information

Attended Noise Monitoring - Quarter Ending September 2013

Attended Noise Monitoring - Quarter Ending September 2013 Unity Mining Level 10, 350 Collins St Melbourne VIC 3000 Version: Page 2 PREPARED BY: ABN 29 001 584 612 Units 7-8, 26-28 Napier Close Deakin ACT 2600 Australia (PO Box 9344 Deakin ACT 2600 Australia)

More information

Bickerdike Allen Partners

Bickerdike Allen Partners 25 CHURCH ROAD, SE19 ENTERTAINMENT NOISE ASSESSMENT Report to Kayode Falebita Kingsway International Christian Centre 3 Hancock Road Bromley-By-Bow London E3 3DA A9540/R01-A-HT 26/07/2012 CONTENTS Page

More information

Ashton Coal. Environmental Noise Monitoring May Prepared for Ashton Coal Operations Pty Ltd

Ashton Coal. Environmental Noise Monitoring May Prepared for Ashton Coal Operations Pty Ltd Ashton Coal Environmental Noise Monitoring May 2018 Prepared for Ashton Coal Operations Pty Ltd Page i Ashton Coal Environmental Noise Monitoring May 2018 Reference: Report date: 5 June 2018 Prepared for

More information

ACOUSTIC BARRIER FOR TRANSFORMER NOISE. Ruisen Ming. SVT Engineering Consultants, Leederville, WA 6007, Australia

ACOUSTIC BARRIER FOR TRANSFORMER NOISE. Ruisen Ming. SVT Engineering Consultants, Leederville, WA 6007, Australia ICSV14 Cairns Australia 9-12 July, 2007 ACOUSTIC BARRIER FOR TRANSFORMER NOISE Ruisen Ming SVT Engineering Consultants, Leederville, WA 6007, Australia Roy.Ming@svt.com.au Abstract In this paper, an acoustic

More information

79 First Avenue Mob: FIVE DOCK NSW 2046 VENTILATED ACOUSTIC ENCLOSURE NOISE EMISSION ASSESSMENT ACOUSTIC SERVICES & ADVICE

79 First Avenue Mob: FIVE DOCK NSW 2046 VENTILATED ACOUSTIC ENCLOSURE NOISE EMISSION ASSESSMENT ACOUSTIC SERVICES & ADVICE Head Office Postal Address T 02 9908 1270 Suite 9 PO Box 270 F 02 9908 1271 38-46 Albany St Neutral Bay 2089 E info@acousticdynamics.com.au St Leonards 2065 ABN: 36 105 797 715 W www.acousticdynamics.com.au

More information

Noise Mitigation Study Pilot Program Summary Report Contract No

Noise Mitigation Study Pilot Program Summary Report Contract No Ohio Turnpike Commission Noise Mitigation Study Pilot Program Summary Report Contract No. 71-08-02 Prepared For: Ohio Turnpike Commission 682 Prospect Street Berea, Ohio 44017 Prepared By: November 2009

More information

Boggabri Coal Mine. Environmental Noise Monitoring October Prepared for Boggabri Coal Operations Pty Ltd

Boggabri Coal Mine. Environmental Noise Monitoring October Prepared for Boggabri Coal Operations Pty Ltd Boggabri Coal Mine Environmental Noise Monitoring October 2017 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring October 2017 Reference: Report date:

More information

ENVIRONMENTAL NOISE MONITORING QUARTER 1, Northparkes Mines PO Box 995 Parkes NSW 2870

ENVIRONMENTAL NOISE MONITORING QUARTER 1, Northparkes Mines PO Box 995 Parkes NSW 2870 ENVIRONMENTAL NOISE MONITORING QUARTER 1, 2018 s PO Box 995 Parkes NSW 2870 Job No: J38252 Report issued: 25 June 2018 ESP ENVIRONMENTAL & SAFETY PROFESSIONALS A division of Enviro-Net Australia Pty. Ltd.

More information

ENVIRONMENTAL NOISE ASSESSMENT

ENVIRONMENTAL NOISE ASSESSMENT ENVIRONMENTAL NOISE ASSESSMENT AT MURPHY BREWERY. Report Dated: 25 June 15 Greenhills House, Kilmoney, Carrigaline, Co. Cork. Tel: 353 21 437433 http://www.env.ie/ TITLE: Environmental Noise Assessment

More information

Wambo Coal Mine and Rail Spur

Wambo Coal Mine and Rail Spur Wambo Coal Mine and Rail Spur Environmental Noise Monitoring November 2017 Prepared for Wambo Coal Pty Limited Page i Wambo Coal Mine and Rail Spur Environmental Noise Monitoring November 2017 Reference:

More information

Standard Guide for Measurement of Outdoor A-Weighted Sound Levels 1

Standard Guide for Measurement of Outdoor A-Weighted Sound Levels 1 Designation: E 1014 84 (Reapproved 1995) e1 AMERICAN SOCIETY FOR TESTING AND MATERIALS 100 Barr Harbor Dr., West Conshohocken, PA 19428 Reprinted from the Annual Book of ASTM Standards. Copyright ASTM

More information

University of York Heslington East Campus Details of Noise Modelling and Noise Survey. Report ref AAc/ /R01

University of York Heslington East Campus Details of Noise Modelling and Noise Survey. Report ref AAc/ /R01 Heslington East Campus Details of Noise Modelling and Noise Survey Report ref Heslington East Campus Details of Noise Modelling and Noise Survey January 2008 Arup Acoustics Admiral House, Rose Wharf, 78

More information

Noise Assessment for Planning Purposes - as per TAN11

Noise Assessment for Planning Purposes - as per TAN11 Noise Assessment for Planning Purposes - as per TAN11 Report No: 1703035R01A Report Status: Final Report (Amended) Dated: 23 October 2017 Purchase order No: n/a Prepared for: Garep Demirci 73 Spencer David

More information

Compliance Noise Survey & Assessment

Compliance Noise Survey & Assessment John Trotter Compliance Noise Survey & Assessment Duralie Coal October 2009 Issued October 2009 Vipac Engineers & Scientists Ltd Hunter Valley / Newcastle, NSW REPORT NO: 29N-09-0002-TRP-470219-0 PREPARED

More information

Status: Rev: Comments Date: Author: Reviewer:

Status: Rev: Comments Date: Author: Reviewer: PAKENHAM EAST PRECINCT STRUCTURE PLAN CITY GATE NOISE ASSESSMENT Rp 002 R03 20171135 28 May 2018 Marshall Day Acoustics Pty Ltd ABN: 53 470 077 191 6 Gipps Street Collingwood VIC 3066 Australia T: +613

More information

Muswellbrook Coal Company

Muswellbrook Coal Company Muswellbrook Coal Company June, 12 Environmental Noise Monitoring Prepared for Muswellbrook Coal Muswellbrook Coal Company June, 12 Environmental Noise Monitoring Reference: Report date: 9 August 12 Prepared

More information

Assessing Entertainment Noise. Using EPA s N-2 Policy (Control of Music Noise from Public Premises)

Assessing Entertainment Noise. Using EPA s N-2 Policy (Control of Music Noise from Public Premises) Assessing Entertainment Noise. Using EPA s N-2 Policy (Control of Music Noise from Public Premises) Noise Limits & Levels for Indoor Venues Indoor Venues 14. The noise limits for indoor venues are: (a)

More information

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate Noise Management Plan Date November 2014 Issue No 1 TABLE OF CONTENTS 1. Introduction/Purpose 2. Responsibility and Authority 3. Noise Monitoring 4.

More information

Wambo Coal Mine and Rail Spur

Wambo Coal Mine and Rail Spur Wambo Coal Mine and Rail Spur Environmental Noise Monitoring August 2017 Prepared for Wambo Coal Pty Limited Page i Wambo Coal Mine and Rail Spur Environmental Noise Monitoring August 2017 Reference: Report

More information

CALGA SAND QUARRY ATTENDED COMPLIANCE NOISE MONITORING 12 APRIL 2017 REPORT NO E VERSION A APRIL 2017 PREPARED FOR

CALGA SAND QUARRY ATTENDED COMPLIANCE NOISE MONITORING 12 APRIL 2017 REPORT NO E VERSION A APRIL 2017 PREPARED FOR ATTENDED COMPLIANCE NOISE MONITORING 12 APRIL 2017 REPORT NO. 01127-E VERSION A APRIL 2017 PREPARED FOR HANSON CONSTRUCTION MATERIALS PTY LTD LOT 151 PEATS RIDGE ROAD CALGA NSW 2250 DOCUMENT CONTROL Version

More information

Southwest Anthony Henday Drive At Wedgewood Heights Residential Neighborhood in Edmonton, AB

Southwest Anthony Henday Drive At Wedgewood Heights Residential Neighborhood in Edmonton, AB aci Acoustical Consultants Inc. 5031-210 Street Edmonton, Alberta, Canada T6M 0A8 Phone: (780) 414-6373 www.aciacoustical.com Environmental Noise Study For Southwest Anthony Henday Drive At Wedgewood Heights

More information

Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex

Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex Noise monitoring during drilling operations Lower Stumble Well Site Balcombe, West Sussex Report ref. PJ3159/13181 Date August 13 Issued to Cuadrilla Resources Limited Issued by Peter Jackson MSc MIOA

More information

Liddell Coal Operations

Liddell Coal Operations Liddell Coal Operations Environmental Noise Monitoring April 2016 Prepared for Liddell Coal Operations Pty Ltd Page i Liddell Coal Operations Environmental Noise Monitoring April 2016 Reference: Report

More information

Cullen Valley Mine. Environmental Noise Monitoring Quarter 2, Prepared for Castlereagh Coal

Cullen Valley Mine. Environmental Noise Monitoring Quarter 2, Prepared for Castlereagh Coal Cullen Valley Mine Environmental Noise Monitoring Quarter 2, 2018 Prepared for Castlereagh Coal Page i Cullen Valley Mine Environmental Noise Monitoring Quarter 2, 2018 Reference: Report date: 28 June

More information

Environmental Noise Measurement Kits

Environmental Noise Measurement Kits SOUND LEVEL METERS dosebadge 5 NOISE DOSEMETER SAFETY OFFICER S NOISE KITS ENVIRONMENTAL NOISE MEASUREMENT KITS ENVIRONMENTAL NOISE MONITORS Environmental Noise Measurement Kits The latest environmental

More information

Rev2-18.Feb Safety Reliability Integrity Training Asset Support Design Support Troubleshooting

Rev2-18.Feb Safety Reliability Integrity Training Asset Support Design Support Troubleshooting KEYSBROOK ENVIRONMENTAL NOISE COMPLIANCE REPORTING Q1 2016 MZI RESOURCES LTD 1370900-5-100-Rev2-18.Feb.2016 www.svt.com.au Perth Brisbane Kuala Lumpur Bangkok Noise Vibration Corrosion Safety Reliability

More information

Pipeline Blowdown Noise Levels

Pipeline Blowdown Noise Levels Pipeline Blowdown Noise Levels James Boland 1, Henrik Malker 2, Benjamin Hinze 3 1 SLR Consulting, Acoustics and Vibration, Brisbane, Australia 2 Atkins Global, Acoustics, London, United Kingdom 3 SLR

More information

91 Street Earth Berm Removal in Edmonton, Alberta

91 Street Earth Berm Removal in Edmonton, Alberta aci Acoustical Consultants Inc. 5031-210 Street Edmonton, Alberta, Canada T6M 0A8 Phone: (780) 414-6373 www.aciacoustical.com Environmental Noise Monitoring For The 91 Street Earth Berm Removal in Edmonton,

More information

REPORT OF NOISE MONITORING OF TUTUR1C SID TRIAL AT EDINBURGH AIRPORT AUGUST TO NOVEMBER 2015 SITE 2: UPHALL

REPORT OF NOISE MONITORING OF TUTUR1C SID TRIAL AT EDINBURGH AIRPORT AUGUST TO NOVEMBER 2015 SITE 2: UPHALL Date: 09 March 2016 REPORT OF NOISE MONITORING OF TUTUR1C SID TRIAL AT EDINBURGH AIRPORT AUGUST TO NOVEMBER 2015 SITE 2: UPHALL Client: Edinburgh Limited Report Author:... Dr R. Peters Principal Consultant

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 1996-2 Second edition 2007-03-15 Acoustics Description, measurement and assessment of environmental noise Part 2: Determination of environmental noise levels Acoustique Description,

More information

Wambo Coal Mine and Rail Spur

Wambo Coal Mine and Rail Spur Wambo Coal Mine and Rail Spur Environmental Noise Monitoring September 2017 Prepared for Wambo Coal Pty Limited Page i Wambo Coal Mine and Rail Spur Environmental Noise Monitoring September 2017 Reference:

More information

Boggabri Coal Mine. Environmental Noise Monitoring August Prepared for Boggabri Coal Operations Pty Ltd

Boggabri Coal Mine. Environmental Noise Monitoring August Prepared for Boggabri Coal Operations Pty Ltd Boggabri Coal Mine Environmental Noise Monitoring August 2018 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring August 2018 Reference: Report date:

More information

Raging River Quarry. Environmental Noise Monitoring Protocol Provisional Operations 11/30/2016

Raging River Quarry. Environmental Noise Monitoring Protocol Provisional Operations 11/30/2016 Raging River Quarry Environmental Noise Monitoring Protocol Provisional Operations 11/30/2016 Introduction The Raging River Quarry operates in unincorporated King County, near Fall City, Washington. King

More information

Boggabri Coal Mine. Environmental Noise Monitoring June Prepared for Boggabri Coal Operations Pty Ltd

Boggabri Coal Mine. Environmental Noise Monitoring June Prepared for Boggabri Coal Operations Pty Ltd Boggabri Coal Mine Environmental Noise Monitoring June 2017 Prepared for Boggabri Coal Operations Pty Ltd Page i Boggabri Coal Mine Environmental Noise Monitoring June 2017 Reference: Report date: 5 July

More information

# Insite RE Inc./ Verizon Wireless Special Use Permit Project Review for Planning and Zoning Commission

# Insite RE Inc./ Verizon Wireless Special Use Permit Project Review for Planning and Zoning Commission #2015-52 Insite RE Inc./ Verizon Wireless Special Use Permit Project Review for Planning and Zoning Commission Meeting Date: October 21, 2015 Request: Location: A Special Use Permit for a wireless communication

More information

R e p o r t th A u g u s t

R e p o r t th A u g u s t N o ise Mon it o r ing R e p o r t L e g a c y W a y T u n n e l M o n i t o r i n g P o s t C o m m is s i o n ing T es ts V e n ti la t ion S t a c ks Jun e 20 1 6 R e p o r t 3557 4 th A u g u s t 2

More information

Swan DH Noise Impact Assessment Report

Swan DH Noise Impact Assessment Report Swan 4-64 6-1 3DH Noise Impact Assessment Report April 9, 2018 Prepared for: ConocoPhillips 34501 East Quincy Avenue Watkins, Colorado 80137 Prepared by: Behrens and Associates, Inc. 13806 Inglewood Avenue

More information

Roof top of Ash Lagoon decantrate pump house Existing Ching Lam noise monitoring station

Roof top of Ash Lagoon decantrate pump house Existing Ching Lam noise monitoring station 3. NOISE 3.1 Monitoring Requirements According to the requirements in the Construction EM&A Manual for Lamma Extension, the baseline levels at the monitoring locations have to be determined prior to the

More information

Black Butte Copper Project Mine Operating Permit Application (Revision 3)

Black Butte Copper Project Mine Operating Permit Application (Revision 3) Mine Operating Permit Application (Revision 3) APPENDIX J: Tintina Montana, Inc. July 17 MEMORANDUM DATE: October 7, 13 TO: FROM: RE: Allan Kirk / Geomin Resources Bob Jacko / Tintina Resources Sean Connolly

More information

Keystone Pipeline Phases 1 & 2 Acoustic Monitoring Report for Canadian Pump Stations

Keystone Pipeline Phases 1 & 2 Acoustic Monitoring Report for Canadian Pump Stations Revision 0 Keystone Project Document # RE-03 [2-4-22-2] ATCO Project # 763000 TransCanada Pipeline Ltd. Keystone Pipeline Project Keystone Pipeline Phases 1 & 2 Acoustic Monitoring Report for Canadian

More information

Project Survey Report Plotting of Noise Isopleth Maps of Robinson Lake Natural Gas Plant

Project Survey Report Plotting of Noise Isopleth Maps of Robinson Lake Natural Gas Plant HAGEMEYER NORTH AMERICA - Technical Services. 6825 West Sam Houston Parkway North, Houston, Texas 77041 OFFICE 713.896.0193 FAX 713.896.6006 WWW.HAGEMEYERNA.COM April 2 nd, 2013 Mr. Justin Clock Health

More information

Technical Note. Noise reducing properties of crash barriers. Performed for WillumTech. AV 1217/11 Project no.: A Page 1 of 19 incl.

Technical Note. Noise reducing properties of crash barriers. Performed for WillumTech. AV 1217/11 Project no.: A Page 1 of 19 incl. Technical Note Noise reducing properties of crash barriers Performed for WillumTech Project no.: A581500 Page 1 of 19 incl. 1 annex 6 October 2011 DELTA Venlighedsvej 4 2970 Hørsholm Denmark Tel. +45 72

More information

Cymbaluk Noise Complaints

Cymbaluk Noise Complaints Decision 20259-D01-2015 Cymbaluk Noise Complaints December 22, 2015 Alberta Utilities Commission Decision 20259-D01-2015 Cymbaluk Noise Complaints Proceeding 20259 Application 20259-A001 December 22, 2015

More information

Statement of Evidence of N I Hegley

Statement of Evidence of N I Hegley IN THE MATTER AND IN THE MATTER of the Resource Management Act 1991 of Notices of Requirement to enable the construction, operation and maintenance of the City Rail Link. Statement of Evidence of N I Hegley

More information

Informations and comments on ECE-TRANS-WP.29-GRB e

Informations and comments on ECE-TRANS-WP.29-GRB e Transmitted by the expert from France Informal document GRB-63-16 (63rd GRB, 16-18 February 2016, agenda item 2) Informations and comments on ECE-TRANS-WP.29-GRB-2016-02e Louis-Ferdinand PARDO (France)

More information

Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC. Final Report Rev 1

Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC. Final Report Rev 1 Lion s Gate Secondary Wastewater Treatment Plant Pile Driving North Vancouver, BC Final Report Rev 1 Noise Impact Assessment RWDI # 1502274 SUBMITTED TO Paul Dufault Project Manager Metro Vancouver 4330

More information

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate

M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate M Sport Evaluation Centre ( MEC ) Dovenby Hall Estate Noise Management Plan Date 31/7/15 Issue No 2e DRAFT TABLE OF CONTENTS 1. Policy Statement 2. Introduction/Purpose 3. Responsibility and Authority

More information

Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014

Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014 Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014 Mackas Sand Pty Ltd ENVIRONMENTAL NOISE MONITORING AUGUST 2014 Prepared by Umwelt (Australia) Pty Limited on behalf of Mackas Sand Pty Ltd

More information

Fundamentals of Environmental Noise Monitoring CENAC

Fundamentals of Environmental Noise Monitoring CENAC Fundamentals of Environmental Noise Monitoring CENAC Dr. Colin Novak Akoustik Engineering Limited April 03, 2013 Akoustik Engineering Limited Akoustik Engineering Limited is the sales and technical representative

More information

CR:247 Invictus. Portable Noise Monitor. Features. Features. Applications

CR:247 Invictus. Portable Noise Monitor. Features. Features. Applications Key Features High performance portable noise monitor Purpose designed for outdoor noise measurement applications Simultaneous measurement of all parameters 120dB measurement range in a single span Colour

More information

Assessment of rail noise based on generic shape of the pass-by time history

Assessment of rail noise based on generic shape of the pass-by time history Proceedings of Acoustics 23 Victor Harbor 7-2 November 23, Victor Harbor, Australia Assessment of rail noise based on generic shape of the pass-by time history Valeri V. enchine, Jonathan Song Science

More information

Memorandum 1.0 Highway Traffic Noise

Memorandum 1.0 Highway Traffic Noise Memorandum Date: September 18, 2009 To: Chris Hiniker, SEH From: Stephen B. Platisha, P.E. Re: Updated CSAH 14 Noise Analysis The purpose of this memorandum is to provide the results of the revised traffic

More information

Template Planning Condition on Amplitude Modulation Noise Guidance Notes

Template Planning Condition on Amplitude Modulation Noise Guidance Notes www.renewableuk.com Template Planning Condition on Amplitude Modulation Noise Guidance Notes December 2013 Template Planning Condition on Amplitude Noise Guidance Notes Modulation Introduction Introduction

More information

Protocol for Ambient Level Noise Monitoring

Protocol for Ambient Level Noise Monitoring July 2015 Protocol for Ambient Level Noise Monitoring L pressure =10.log [10 (Lp/10) - 10 (LpBackground/10) ] L pressure = 10.log [10 (Lp/10) - 10 (LpBackground/10) ] CENTRAL POLLUTION CONTROL BOARD P

More information

NETWORK RAIL BORDERS RAILWAY OPERATIONAL NOISE AND VIBRATION (YEAR 1, ROUND 2) REP-003. September 2016

NETWORK RAIL BORDERS RAILWAY OPERATIONAL NOISE AND VIBRATION (YEAR 1, ROUND 2) REP-003. September 2016 Ref:15375 OPERATIONAL NOISE AND VIBRATION (YEAR 1, ROUND 2) 15375-REP-003 September 2016 Registered Office Park House 39 Bo ness Road Grangemouth Stirlingshire FK3 8AN Tel: +44 (0)1324 878822 Fax: +44

More information

Methods for rating and assessing industrial and commercial sound

Methods for rating and assessing industrial and commercial sound BS 4142:2014 BSI Standards Publication Methods for rating and assessing industrial and commercial sound BS 4142:2014 BRITISH STANDARD Publishing and copyright information The BSI copyright notice displayed

More information

Noise Monitoring Program

Noise Monitoring Program for Document Table of Contents for... 1 1 Purpose... 3 1.1 Purpose... 3 2 Noise Impact Assessment Criteria... 3 2.1 Noise Criteria... 3 3 Measurement and Evaluation... 6 3.1 Monitoring Locations... 6 3.2

More information

Assessing the accuracy of directional real-time noise monitoring systems

Assessing the accuracy of directional real-time noise monitoring systems Proceedings of ACOUSTICS 2016 9-11 November 2016, Brisbane, Australia Assessing the accuracy of directional real-time noise monitoring systems Jesse Tribby 1 1 Global Acoustics Pty Ltd, Thornton, NSW,

More information

City of Hamilton INFORMATION FOR CONDITIONAL USE PERMIT

City of Hamilton INFORMATION FOR CONDITIONAL USE PERMIT City of Hamilton INFORMATION FOR CONDITIONAL USE PERMIT There is a $200.00 non-refundable fee for each request. Requests must be completed and submitted to the Public Works Department, City of Hamilton,

More information

Appendix G Noise and Vibration Assessment

Appendix G Noise and Vibration Assessment Appendix G Noise and Vibration Assessment Annex G1: Noise Perception and Terminology Annex G2: Baseline Noise Monitoring Annex G3: Construction Information Annex G4: Operational Information Annex G1: Noise

More information

APPENDIX F BASELINE NOISE REPORT

APPENDIX F BASELINE NOISE REPORT APPENDIX F BASELINE NOISE REPORT APPENDIX F BASELINE NOISE REPORT F BASELINE NOISE REPORT Contents Summary A Baseline Noise Report was prepared for Damhead Creek 2. This is presented in this Appendix

More information

Appendix D: Preliminary Noise Evaluation

Appendix D: Preliminary Noise Evaluation Appendix D: Preliminary Noise Evaluation Acoustics The study of sound and its properties is known as acoustics. By considering basic physical properties of sound and the acoustic environment, the potential

More information

1 Dockland Central, Guild St, Dublin 1 1 Lárcheantar na ndugaí, Sráid na ngildeanna, BÁC 1 Tel Teil

1 Dockland Central, Guild St, Dublin 1 1 Lárcheantar na ndugaí, Sráid na ngildeanna, BÁC 1 Tel Teil An Coimisiún um Rialáil Cumarsáide 1 Dockland Central, Guild St, Dublin 1 1 Lárcheantar na ndugaí, Sráid na ngildeanna, BÁC 1 Tel Teil +353 1 804 9600 www.comreg.ie Programme of Measurement of Non-Ionising