2 WIRE - LOOP POWERED AND ISOLATED TRANSMITTER FOR TERMORESISTANCE AND THERMOCOUPLE. resistances. The RTD input may be with 2,3 or 4 wire connection.
|
|
- Christine Casey
- 5 years ago
- Views:
Transcription
1 EN T WIRE - LOOP POWERED AND ISOLATED TRANSMITTER FOR TERMORESISTANCE AND THERMOCOUPLE. GENERAL DESCRIPTION The T instrument converts and transmits the input read into a normalized signal current for..0 ma loop. The signal input may come from thermocouple J, K, R, S, T, B, E, N (EN 6058) sensors or RTD (thermoresistances) like Pt 00 (EN 605), Ni 00 (DIN 60), Pt 500, Pt 000; T besides can read voltages and resistances. The RTD input may be with, or wire connection. GENERAL FEATURES High precision. 6 bit resolution. Isolation 500 Vac. Compact size and fast connection with spring terminals. Configuration by PC with dedicated software downloadable at THECNICAL FEATURES Output/Power supply Operating voltage :..0 V DC Current output :..0 ma Load Resistance : 6 V DC, ma (see on pag. : Load resistance vs minimum functioning voltage diagram ) Resolution : µa ( > bit) Output in case of over-range:0,5% of full scale (see the table on pag. 5) Output in case of fault : 05% of full scale (see the table on pag. 5) Current output protection : ~ 0 ma Potentiometer input Value of potentiometer : Resistance of potentiometer up to 00 without external resistor. Exitation current : 5 µa. Input inpedance : 0 M TC input Input impedance: 0 M Cold junction compensation: ±,5 C; Settable. Sensor fault detection : YES, Settable Ingresso mv Input impedance : 0 M ENGLISH - /
2 RTD / Resistance inputs Exitation current : 5 µa Maximum cable resistance : 5 Influe nce cable resistance : 0, 00 / Other features Network freq. Rejection : Error caused by EMI (*) : Insulation: Sampling Time : Response time (0..90 %) : Degree protection : Sensor fault detection : Environmental conditions : Storage Temperature: Connections : Conductor Section : Wire stripping : Box: Dimensions : 50 Hz and 60 Hz (Minimum 60 db) < 0,5 % 500 V 00 ms <60 ms IP 0 YES Temperature C Humidity 0-90 % at 0 C (non-condensing) Altitude: up to 000 m.a.s.l C Spring terminals 0,..,5 mm 8 mm Nylon / glass, (black colour) 0,0 mm x 0,0 mm Standards : EN /00-0 (elettromagnetic emission, industrial environment) EN /006-0 (eletromagnetic immunity, industrial environment) Diagram: Load resistance vs minimum functioning voltage 00 R Load =((U-)/0.0) Minimun functioning voltage U (V DC) ENGLISH- /
3 Table range of input Input Range Calibration error EMI(*) Span Resolution Standard 0, % 50 C 5 µv EN 6058 J C Type input Thermocouple J,K,T,N,E Thermocouple B, R, S RTD (***) Resistance F.S. = 00 < 0,5 % K C 0, % < 0,5 % 50 C 5 µv R C 0, % < 0,5 % 00 C 5 µv S C 0, % < 0,5 % 00 C 5 µv T C 0, % < 0,5 % 50 C 5 µv B(**) C 0, % < 0,5 % 00 C 5 µv E C 0, % < 0,5 % 50 C 5 µv N C 0, % < 0,5 % 50 C 5 µv Ni C 0, % < 0,5 % 0 C 6 m Pt C 0, % < 0,5 % 0 C 6 m Pt C 0, % < 0,5 % 0 C 8 m Pt C 0, % < 0,5 % 0 C 8 m Voltage mv mv 0, % < 0,5 %,5 mv 5 µv Potent , % < 0,5 % 0 % % Resist , % < 0,5 % 0 6 m Resist , % < 0,5 % 50 8 m EN 6058 EN 6058 EN 6058 EN 6058 EN 6058 EN 6058 EN 6058 DIN 60 EN 605 Table of accurcy measure : The greater of the sun of (A+B) and C A : % of measure B : % of Span C : Minimum 0.5 C C 0. C 0 m Resistance F.S. = 60 Voltage mv Potentiometer Temperature Coefficient : % / C * EMI : Electtromagnetic interferences. ** TC B : between C the measure is null. ***RTD : Errors calculate on the value of the resistive sensor. 00 m 5 µv 0.0 % ENGLISH- /
4 Configurazione di Fabbrica The instrument is set by the factory with the following configuration (except for other indications on the box): TC wiring Cold junction compensation Input filter Reversed output TC type Measurement Range Start Measurement Full- Scale Output signal in case of fault +, - YES Disable NO K 0 C 000 C Towards the top of the output range. YES: at,5 % over-range values is accetable; at 5% over-range value is considered a fault. Custumized Setting by PC and accessories The configuration by PC use (see the drawing below) is possible with the following accessories: SP: USB to RS/TTL PM00:connection cable between SP and T EASYLP: Dedicated programming software. The module may be programmed even if it is not supplied by the..0 ma loop, since the power supply is provided through the programmer by programming connector. Once the user has at his disposal the above listed accessories, the following parameters may be set : Start and Full scale values of measure. RTD Connection: wires, wires or wires. Measurement filter: Disable. Output: Normal (..0 ma) or reversed (0.. ma). Type input. Cable Resistance Compensation for wires measurement. Output signal in case of fault: t owards the bottom of the output range or towards the top of the output range. Over-Range (*): NO ( the fault alone causes a,5% over-range value) or YES ( a,5% over-range value is accettable a 5 % over-range value is considered a fault). Cold junction compensation : YES/NO ENGLISH- /
5 It is besides possible the calibration of the output scale.. Output signal Limit Over-range / Fault ±,5 % Fault ± 5 % 0 ma 0, ma ma ma,6 ma <, ma (**) See the table above for the corresponding values Frontal side: Terminals position and enumeration. Raising the plastic protection using the appropriate slot.. Move the plastic protective as in the drawing. Programming connector Electrical connection Input The module allows you to read the thermocouple : J, K, R, S, T, B, E, N and thermoresistance : Pt00 (EN 605), Pt500, Pt000 Ni00 with, or wiring connection; besides T can be used to read voltage (mv) and resistance. The use of shield cables is recommended for the electronic connections -wire connection This connection can be used for short distances ( < 0 m) between module and probe, you should be note that it adds an error (which may be removed by sofware programming) equivalent to the resistance contributed by the connection cables to the measurement. The module must be programmed by PC for wires connection. -wire connection This connection can be used for medium-long distances ( > 0 m ) between module and probe. The instrument performs compensation for the resistance of the connection cables. For a correct compensation the resistance values of each conductors must be the same. The module must be programmed by PC for wires connection. ENGLISH-5/
6 -wire connection This connection can be used for medium-long distances ( > 0 m ) between module and probe. Provides the maximum precision because the instrument measure the resistance of the sensor independently of the resistance of the connection cables. The module must be programmed by PC for wires connection. Potentiometer input A potentiometer with resistence between may be connected directly at module. If the potentiometer has a resistance greater than, K up to 00 K will be necessary to use a resistor in parallel with potentiometer: Ra equals to,5 K RTD wire Connection RTD wire Connection RTD wire Connection TC Connection - + Resistance Connection Potentiometer Connection Voltage (mv) Connection - + Ra =,5 K Output Pot. Current Loop connection (regolated current). The use of shield cables is recommended for the electronic connections. 5 6 Iout RLoad Note: in order to reduce the instrument's dissipation, we recommend guaranteeing a load of > 50 Ω to the curren t output. - U ENGLISH- 6/
7 Pattern of connecting terminal with push-wire connection Size and dimensions ENGLISH - /
8 aaa Disposal of Electrical & Electronic Equipment (Applicable throughout the European Union and other European countries with separate collection programs) This symbol, found on your product or on its packaging, indicates that this product should not be treated as household waste when you wish to dispose of it. Instead, it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences to the environment and human health, which could otherwise be caused by inappropriate disposal of this product. The recycling of materials will help to conserve natural resources. For more detailed information about the recycling of this product, please contact your local city office, waste disposal service or thè retail store where you purchased this product. This document is property of SENECA srl. Duplication and reprodution are forbidden, if not authorized. Contents of the present documentation refers to products and technologies described in it. All technical data contained in the document may be modified without prior notice Content of this documentation is subject to periodical revision. SENECA s.r.l. Via Austria, PADOVA - ITALY Tel Fax info@seneca.it - ENGLISH- */*
LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION
EN K09LV LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION General Description The K09LV instrument is a three points galvanic insulator, with input on high sensitivity voltage, and active output.
More informationZ170REG-1. Universal converter module with galvanic insulation between 2 analog outputs
USER MANUAL EN Z170REG-1 Z Line Universal converter module with galvanic insulation between 2 analog outputs Chapter index Page 1. Identification data 1 2. Preliminary warnings 2 3. Description and characteristics
More informationZ-10-D-IN. RS485 Modbus Module 10 Digital Inputs
S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical specifications - Installation rules - Electrical connections - Modbus connection rules - DIP-switches settings -
More informationSENECA s.r.l. Via Austria, PADOVA ITALY Tel Fax
Language manual Product Description Series of product INSTALLATION AND USER S GUIDE English T01DC100 Passive transducer of direct current 100 A, for 4 0 ma current loop T Contents: 1.0 Disclaimer.0 Description
More informationFREQUENCY => CURRENT / VOLTAGE CONVERTER Z111
EN FREQUENCY => CURRENT / VOLTAGE CONVERTER Z111 GENERAL FEATURES Pulse input for all the most commonly-used sensors: mechanical contact, reed, npn with 2 and 4 wires, pnp with 3 wires and 24V DC power
More informationZ170REG. Universal converter module with galvanic insulation between 2 analog outputs
USER MANUAL EN Z170REG Z Line Universal converter module with galvanic insulation between 2 analog outputs Chapter index Page 1. Identification data 1 2. Preliminary warnings 2 3. Description and characteristics
More informationINSTALLATION MANUAL. SENECA s.r.l. Via Germania, Z.I. CAMIN PADOVA ITALY Tel Fax
Z-PC Line INSTALLATION MANUAL Z-DAQ-PID Analog, universal IN/OUT conversion and PID regulation with ModBUS RTU protocol based on RS485 serial interface Chapter index Page 1. Identification data 1 2. Preliminary
More informationHigh-precision process calibrator Model CED7000
Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry
More informationAnalogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J
Electrical temperature measurement Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J WIKA data sheet TE 91.01 for further approvals
More informationTemperature measurement TMD 832 head transmitter
Technical information TI 062R/09/en Mat.-Nr. 510 00782 Temperature measurement TMD 832 head transmitter SMART head transmitter with HART protocol for RTD, Thermocouple and mv input signals Applications
More informationP5201 Universal Programmable Transmitters with Galvanic Isolation
Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to
More informationAnalogue Temperature Transmitter
TE 19.01 Electrical Temperature Measurement Analogue Temperature Transmitter Configurable Ranges, Head Mounting for Pt100 Resistance Thermometers for Thermocouples Applications Plant construction Power
More informationMODEL: M6SXU MODEL: M6SXU [1][2] [3][4]
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)
More informationTxBlock-USB Transmitter
Transmitter TEMPERATURE TRANSMITTER - OPERATING MANUAL V1.0x I INTRODUCTION The TxBlock-USB is a 4-20 ma 2-wire temperature transmitter for head mount, powered by the current loop. The output current is
More informationAdditel 875 Series Dry Well Calibrators
Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect
More informationR24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY
Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the
More informationCALYS Transportable documenting multifunction calibrator with high accuracy 0.01%
Transportable documenting multifunction calibrator with high accuracy 0.01% CALYS 1200 is the ideal solution to simultaneously simulate and measure with a high accuracy of 0.01%: voltage, current, resistance,
More informationDigital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting
Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03
More informationCALYS 50. Field multifunction calibrator for basic use
Field multifunction calibrator for basic use CALYS 50 field multifunction calibrator is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field
More informationSEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER
RTD, THERMOCOUPLE, THERMISTOR (BMS SENSORS), SLIDE WIRE, mv AND RESISTANCE INPUTS ma, VOLTAGE OR BIPOLAR VOLTAGE OUTPUT SENSOR OFFSET (TEMPERATURE) 22 SEGMENT USER LINEARISATION (PROCESS) CONFIGURATION
More informationFC-33, DC SELECTABLE SIGNAL CONDITIONER
FC-33, DC SELECTABLE SIGNAL CONDITIONER Description. The FC-33 is a DIN rail or side mount, selectable input/output signal conditioner with 1500VDC isolation between input and output, and 1500VDC isolation
More informationC330 / C330X PC-Programmable Universal, 2-wire Transmitter
C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and
More informationUSB-2404-UI Specifications
Specifications Document Revision 1.1, April, 2011 Copyright 2011, Measurement Computing Corporation All specifications are subject to change without notice. Typical for the range 0 to 60 C unless otherwise
More informationMODEL: R30US4. Remote I/O R30 Series
Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable
More informationMODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT
Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer
More informationTemperature Transmitters - Head Mounted
XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More informationCALYS 100. Field precision documenting multifunction calibrator
Field precision documenting multifunction calibrator is a precision documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench
More informationCALYS 75. Field documenting multifunction calibrator
Field documenting multifunction calibrator is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries.
More informationTemperature head transmitter itemp PCP TMT 181
Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationSEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.
INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business
More informationSEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.
INDEX SECTION CONTENTS PAGE NO. SEM104 SERIES SEM104P Pt100 Temperature Transmitter SEM104TC Thermocouple Temperature Transmitter SEM104P 1 1.0 DESCRIPTION 2 2.0 SPECIFICATION 2 3.0 INSTALLATION 24 4.0
More informationAdditel 875 Series Dry Well Calibrators
Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect
More informationMEMOCAL 2000/2000S. Hand-held calibrator
MEMOCAL 2000/2000S Hand-held calibrator MEMOCAL 2000 Very low temperature drift (0.1µV/ C) Accuracy: 0.015% of span Power supply: standard AA size battery (Alkaline, NiCd or Ni-MH) Measurement & generation
More informationProcess displays For standard signals, temperature, resistance measurement
Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions
More informationMODEL: M2XU MODEL: M2XU [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and
More informationMultifunction Intelligent 4-wire Isolated Signal Conditioner
Multifunction Intelligent 4-wire Isolated Signal Conditioner IPAQ-4L is a fully universal and intelligent 4- wire (mains powered) transmitter for temperature measurement and signal conditioning applications.
More informationCALYS 150. Advanced documenting multifunction calibrator thermometer
Advanced documenting multifunction calibrator thermometer , most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer
More informationTemperature transmitter itemp PCP DIN rail TMT 121
Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationRTD/RES. Pot. Output type Min Max Min. span. Current 4 ma 20 ma 4 ma. Burn-out values Max. output value 21.8 ma Min. output value 2.
DN Rail Signal Transmitter Phone: 9 - e-mail:datexel@datexel.com- www.datexel.com Universal isolated transmitter configurable by Dip-Switch or PC DAT FEATURES - Universal configurable input for: mv, Tc,
More informationIsolators A3/1.
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationMODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC
MODEL: MLU Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step
More informationTemperature Transmitters - DIN Rail Mounted
XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More informationCALYS 150. Advanced documenting multifunction calibrator thermometer
Advanced documenting multifunction calibrator thermometer, most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer
More informationUniversal Intelligent 2-wire DIN Rail Transmitters
Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version
More informationTemperature Measurement
Temperature Measurement SITANS T00 Overview Application SITANS T00 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective
More informationCONTA-ELECTRONICS. Converter Units
CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to
More informationUSB-TEMP and TC Series USB-Based Temperature Measurement Devices
USB-Based Temperature Measurement Devices Features Temperature and voltage measurement USB devices Thermocouple, RTD, thermistor, or semiconductor sensor measurements Eight analog inputs Up to ±10 V inputs*
More informationTemperature Transmitter ZTT series
BT.11.13 ZT/I ZTT series The ZTT series transmitter accepts the most commonly used temperature sensors (RTD, T/C) as well as mv and slide wire signals. All the models adopt a 2 wire 4...20mA output signal
More informationONE CALIBRATOR ONLY MAIN FEATURES:
ONE CALIBRATOR ONLY The MEMOCAL 2000 is a lightweight versatile, portable, hand-held calibrator developed to solve two different and coexisting customer needs: field calibration (maintenance) and laboratory
More informationPROCESS & TEMPERATURE CONTROLLERS
PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs
More informationIsolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Linearized 4-Wire RTD Input 5B35 FEATURES Single-channel signal conditioning module that Amplifies, Protects, Filters, and Isolates Analog Input. Isolates and protects a wide variety of four-wire
More informationCALYS 150. Advanced documenting multifunction calibrator thermometer
Advanced documenting multifunction calibrator thermometer , most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer
More informationTemperature Measurement
Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal
More informationAssembly. Front view. Parametrization interface. Power Bus
Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and
More informationVersaPoint I/O Module
GFK-2012A March 2010 Module provides two-input channels for measuring signals from standard thermocouples. It supports thirteen different thermocouples types. In addition, it accepts linear voltage inputs
More informationhigh accuracy tester-calibrator PJ 6301
high accuracy testercalibrator PJ 6301 PJ6301 is a highaccuracy instrument: ± 0.005% with 600,000 measuring counts on voltage and current ranges; for thermocouple and for RTD measurement resolution. Simultaneous
More informationJUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationIsolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series
Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners DRLP Series U ±0.03% Accuracy (Typical) U ±0.01% Linearity U 1500Vrms Transformer Isolation and 240Vrms Field-Side Protection U Wide Loop
More informationIsolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW
Isolated, Linearized Thermocouple Input 5B47 FEATURES Isolated Thermocouple Input. Amplifies, Protects, Filters, and Isolates Thermocouple Input Works with J, K, T, E, R, S, and B-type thermocouple. Generates
More informationPROGRAMMABLE FIELD TEMPERATURE TRANSMITTER
Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance
More informationDSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters
Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and
More informationUSER MANUAL Z-8TC. Via Germania, Z.I. CAMIN PADOVA ITALY. Via Svizzera, Z.I. CAMIN PADOVA ITALY
USER MANUAL Z-8TC SENECA s.r.l. Via Germania, 34 35127 Z.I. CAMIN PADOVA ITALY Via Svizzera, 17 35127 Z.I. CAMIN PADOVA ITALY Tel. +39.049.8705355 8705359 Fax. +39.049.8706287 Web site: www.seneca.it Technical
More informationUser's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters
User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationTwo-Wire Programmable Transmitter for:
TM Smart Process Instrumentation Revision 2 Two-Wire Programmable Transmitter for: Industrial Thermocouple or RTD Temperature Measurements Highlights: Exceptional speed and accuracy Guaranteed measurement
More informationDigital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version
Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building
More informationMODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC
Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step Cal calibration
More informationSEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER
UNIVERSAL INPUT, DUAL CHANNEL ATEX & IEC Ex Version MATHS FUNCTIONS SENSOR CHARACTERISTICS DOWNLOAD VIA USB PORT ALLOWS FOR CUSTOM TYPES FLASH TESTED TO 4 KV DC INTRODUCTION The SEM210 is a universal transmitter
More informationitemp PA TMT184 Technical information
Technical information itemp PA TMT184 Temperature head transmitter with PROFIBUS-PA interface. Supply and digital communication using PROFIBUS-PA, for installation in a Form B sensor head. Features and
More informationMCR-T-UI(/NC) MCR-T-UI-E(/NC)
MCR-T-UI(/) MCR-T-UI-E(/) Programmable Temperature Transducers for Resistance Thermometers and Thermocouples INTERFACE ata Sheet 00_0_en PHOENIX CONTACT - 0/00 escription A universal temperature measuring
More informationDigital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version
Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications
More informationModular Smart Interfaces
Modular Smart Interfaces Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement Modular Smart Interfaces MSI Series Modular Smart Interfaces (MSI) bring an expanded
More informationSINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs
SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.
More informationHART Compatible Intelligent 2-wire DIN Rail Transmitters
HART Compatible Intelligent 2-wire DIN Rail Transmitters MESO-L is a Smart and universal 2-wire DIN Rail transmitter for temperature and other measurement applications. MESO-LX is the Intrinsic Safe version
More informationGeneral Specifications
General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.
More informationIsolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated, Frequency Input 5B45 / 5B46 FEATURES Isolated Frequency Input. Amplifies, Protects, Filters, and Isolates Analog Input. Generates an output of 0 to +5V proportional to input frequency. Model
More informationOuput Loop Powered Products Section C
Ouput Loop Powered Products Section C An output loop powered (or signal powered) isolator derives its power from the voltage drop across the device's current loop output. Because they require no separate
More information250T Loop-Powered (2-wire) Transmitter 250T. Input. Isolation. 350T DC-Powered (3-wire) Transmitter 350T. Input. Isolation
Series Isolated Transmitters 250T Loop-Powered (2-wire) Transmitter PLC / DCS 250T S Sense Resistor P L IN Input Isolation OUT 4-20mA RLOAD 24V DC 350T DC-Powered (3-wire) Transmitter PLC / DCS 350T PWR
More information09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i
Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation
More informationUniversal Intelligent 2-wire DIN Rail Transmitters
Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version
More informationIsolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationfor installation into terminal head form B and for installation on DIN rail Output signals : 4 to 20 ma : 4 to 20 ma 0 to 10 V
sales@jumo.co.uk info.us@jumo.net Page 1/12 JUMO dtrans T0 Programmable twowire transmitter for installation into terminal head form B and for installation on DIN rail Brief description The transmitters
More informationNI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O
DATASHEET NI REM-11120 Temperature Input Module for Remote I/O 4 thermocouple channels with input range of ±100 mv 1 voltage input channel with range of ±5V 24-bit resolution Optional external CJC or additional
More informationModicon Momentum automation platform 0
Presentation, description Presentation The Momentum analog input bases enable acquisition of various analog values encountered in industrial applications, including: b b b b Standard high level (± 5 V,
More informationmemocal certo Multifunction Documenting Process Calibrator Accuracy ±0.01% rdg for all TC s and RTD s Complies with AMS2750 (secondary standard)
memocal certo Multifunction Documenting Process Calibrator Accuracy ±0.01% rdg for all TC s and RTD s Complies with AMS2750 (secondary standard) Light, Rugged and Ergonomic for Field Use, with Anti-shock
More informationTT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H
Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 1261 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de TT2780 Data Sheet TT2780
More informationADAM 4000/4100 Series
ADAM 4000/4100 Series Common Dimensions Communication RS-485 (2-wire) to host Speeds: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps (ADAM-4080, ADAM-4080D only support up to 38400 bps) Max. communication
More informationUser's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters
User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More information0 2 1 â Ó. itemp HART TMT182. Technical Information
Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for
More informationHigh-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals
Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building
More informationTwo Wire Temperature Transmitter LTX-3000-H-2 LTX-3000-H LTX-3000-W LTX-3000-D
Two Wire Temperature Transmitters (Product Code 18.1 To 18.8) LTX-3000-H-2 LTX-3000-H LTX-3000-W LTX-3000-D Model Wise Description: Sr.No Model Product Description 18.1 LTX-3000-H Two Wire Temperature
More informationSpecifications. 744 Users Manual
80T-150U Temperature Probe 80PK series thermocouples 80i-410 Clamp-on DC/AC Current Probe 80i-1010 Clamp-on DC/AC Current Probe 80i-500s Clamp-on AC Current Probe (requires the Y9108 adapter) 80i-1000s
More informationTRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type
TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type USER S MANUAL Contents 1. APPLICATION...5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1. Fitting way...7 4.2. External
More informationGeneral Specifications
General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring
More informationJUMPFLEX 857 Series ma ma V. Signal Conditioning/Relay and Solid State Modules
JUMPFLEX Series Signal Conditioning/Relay and Solid State Modules...0 V 0...0 ma...0 ma JUMPFLEX Series Today s factory automation and process control applications require conversion, isolation, and transmission
More informationHand-held temperature calibrator Model CEP3000
Calibration technology Hand-held temperature calibrator Model CEP3000 WIKA data sheet CT 82.01 Applications Calibration service companies and service industry Measurement and control laboratories Industry
More informationHigh Performance Process & Temperature Controllers
C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal
More informationDatasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C
Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P - 4-20mA output, default range supplied 0-100 C ENGLISH The TX203P RTD in-head mounted temperature transmitter connects
More informationIsolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC
Selection Guide PAD Series Modules Multi channel Low bandwidth - for static signals Isolation Digital output (RS-485) Exchangeable For DEWETRON systems with built-in DAQ rack Module # CH Input type Ranges
More informationMODEL: M6SXT. POWER INPUT DC Power R: 24 V DC
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection 5.9-mm wide ultra-slim design Low profile
More information4-20mA, 0-10V and general process measuring bargraph displays
Page 1 of 6 Digital panel meters Large displays Bargraphs Transmitters 4-20mA, 0-10V process input bargraph displays Display almost any physical variable... The bargraph displays on this page accept most
More information