General Specifications

Size: px
Start display at page:

Download "General Specifications"

Transcription

1 General Specifications GS 1C22H1-EN EJA11W, EJA11N and EJA11Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2] Diaphragm seals are used to prevent process medium form entering directly into the -sensing assembly of the differential transmitter, they are connected to the transmitter using capillaries filled with fill fluid. Model EJA11W, EJA11N and EJA11Y Diaphragm Sealed Differential Pressure Transmitters can be used to measure liquid, gas, or steam flow, as well as liquid level, density, and. They output a to 2 ma DC signal corresponding to the measured differential. The transmitters also feature remote setup and monitoring through communications with the model BT2/1 BRAIN TERMINAL, CENTUM CS/XL system etc. STANDARD SPECIFICATIONS Refer to GS 1C22T2-EN for FOUNDATION Fieldbus communication type and GS 1C22T3-EN for PROFIBUS PA communication type marked with. Measurement Ranges: Capsule Measurement Span Measurement Range M H 2.5 to 1 kpa {25 to 1 mmh2o} 25 to 5 kpa {.25 to 5 kgf/cm 2 } -1 to 1 kpa {-1 to 1 mmh2o} -5 to 5 kpa {-5 to 5 kgf/cm 2 } Output Signal : to 2 ma DC, 2-wire system with digital communication Failure Alarm: Output status at CPU failure and hardware error; Up-scale: 11%, 21.6 ma DC or more (standard) Down-scale: -5%, 3.2 ma DC or less -2.5%, 3.6 ma DC or less (Optional code /F1) Note: Applicable for Output signal code D and E Supply Voltage : 1.5 to 2 V DC for general use and flameproof type 1.5 to 32 V DC for lightning protector (Optional code /A) 1.5 to 3 V DC for intrinsically safe, Type n, nonincendive, or non-sparking type 1.5 to 2 V DC for TIIS intrinsically safe type Conditions of Communication Line : Power supply voltage; 16. to 2 V DC Load resistance; See Figure 1. Note: In case of an intrinsically safe transmitter, eternal load resistance includes safety barrier resistance. Communication distance; 2 km, when CEV polyethylene-insulated PVCsheathed control cables are used. Note: Communication distance varies depends on kind of cable. Load capacitance;.22 µf or less. Load inductance; 3.3 mh or less. Spacing from power line; 15 cm or more. Input impedance of receiver connected receiving resistance; 1 kω or more at 2. khz (See Optional Specifications for Intrinsically safe type) Accuracy: See Table 2-1, 2-2 and 2-3. Ambient Temperature Limits: - to 6 C (- to 1 F) (general-use type) -3 to 6 C (-22 to 1 F) (with integral indicator) Note : The ambient temperature limits must be within the fill fluid operating temperature range, see Table 1. (See Optional Specifications for Eplosion-protected types) Ambient Temperature Effect: See Table 2-1, 2-2 and 2-3. Process Temperature Limits: See Table 1. (See Optional Specifications for Eplosion-protected types) Ambient Humidity Limits: 5 to 1 % R.H.(at C) Working Pressure Limits: 2.7 kpa abs{2 mmhg abs} to flange rating For atmospheric or below, see Figure 2. Static Pressure Effect: See Table 2-1, 2-2 and 2-3. Power Supply Effect : ±.5 %/V (21.6 to 32 V DC, 35 Ω) Mounting: Transmitter; 2-inch pipe mounting Diaphragm seals; flange mounting Mounting Flange Rating: See Model and Suffi Codes. Flange conforming to ANSI are serration-worked on the gasket surfaces (ANSI B16.5) Note: For model EJA11W wetted parts material code H, T, or U, no serration is worked. Yokogawa Electric Corporation , Nakacho, Musashino-shi, Tokyo, 1-75 Japan Tel.: Fa.: GS 1C22H1-EN Copyright July nd Edition Jan. 216

2 Degrees of Protection: IP67, Type X Eplosion-protected Construction: See Optional Specification. Electrical Connection: See Model and Suffi Codes. Amplifier Housing: Cast aluminum alloy or JIS SCS1A stainless steel (optional) Transmitter Material: Cover flange; JIS SCS1A Cover flange bolts; See Model and Suffi Codes. Diaphragm Seals Material: Diaphragm and other wetted parts; See Model and Suffi Codes. Capillary tubes; JIS SUS316 Protection tubes; JIS SUS3 PVC-sheathed (Ma, operating temperature of PVC, 1 C (212 F)) Fill fluid; See Table 1. Damping Time Constant: (Sum of time constants for amplifier assembly and capsule assembly including diaphragm seals) Amplifier assembly time constant; Can be set in 9 increments from.2 to 6 sec. Capsule assembly time constant; Capsule M H Time Canstant (sec) Appro..5 Appro..5 Approimate values obtained at normal temperature when the capillary length is 5 m, process flange size/ material code D, E, F and the fill fluid code is A. Painting: Polyurethane resin baked finish Deep sea moss green (Munsell.6GY3.1/2.) Integral Indicator: LCD digital indicator (optional) Eternal Zero Adjustment : Continuously adjustable Resolution;.1 % of span Zero Adjustment Limits: Zero can be fully elevated or suppressed as long as low and high range value are within the measurement range limits of the capsule. Tag Plate: JIS SUS3 or SUS316 Weight: 17.3 kg (3.2 lb) Model EJA11W with mm JIS 1K flange, capillary length 5 m; with integral indicator and mounting bracket kg (5.6 lb) Model EJA11N with 1 mm JIS 1K flange, X2=1, capillary length 5 m; with integral indicator and mounting bracket. 2.1 kg (. lb) Model EJA11Y with 1 mm JIS 1K flange, X2=1, capillary length 5 m; with integral indicator and mounting bracket. Add 1. kg (3.1lb) for JIS SCS1A stainless steel amplifier housing. EMC Conformity Standards : EN Class A, Table2 (For use in industrial locations) EN European Pressure Equipment Directive 97/23/EC: Sound Engineering Practice Safety Requirement Standards: EN611-1 Altitude of installation site: Ma. 2, m above sea level Installation category: I Pollution degree: 2 Indoor/Outdoor use < Settings When Shipped > Tag Number As specified in order *1 Output Mode Linear unless otherwise specified in order Display Mode Linear unless otherwise specified in order Operation Mode Normal unless otherwise specified in order Damping Time Constant *2 2 sec. Calibration Range Lower As specified in order Range Value Calibration Range Higher As specified in order Range Value Calibration Range Units Selected from mmh2o, mmaq, mmwg, mmhg, Pa, hpa, kpa, MPa, mbar, bar, gf/cm 2, kgf/cm 2, inh2o, inhg, fth2o, or psi. (Only one unit can be specified) *1: Up to 16 alphanumeric characters (including - and ) will be entered in the amplifier memory. *2: If using square root output, set damping time constant to 2 sec. or more. 2 GS 1C22H1-EN Jan. 27, 216-

3 3 6 Eternal load resistance R= E Digital Communication range BRAIN and HART Process temperature for fill fluid code B Transmitter ambient temperature range (For fill fluid code A, B) Process temperature for fill fluid code A Process temperature for fill fluid code C Flange ma. working R (Ω) 25 1 {75} Working kpa abs {mmhg abs} Atmospheric Power supply voltage E (V DC) Figure 1. Relationship Between Power Supply Voltage and Eternal Load Resistance F1E.ai 1 {75} 2.7 {2} 1 {7.5}.1 {.75} Process Temperature ( C) F2E.ai Figure 2. Working Pressure and Process Temperature Table 1. Process Temperature and Ambient Temperature Process Temperature *1-1 to 25 C ( 1 to 2 F ) Ambient temperature *2-1 to 6 C ( 1 to 1 F ) Silicone Oil Fluorinated Oil Ethylene Glycol Fill Fluid Code A Fill Fluid Code B Fill Fluid Code C Fill Fluid Code D Fill Fluid Code E -3 to 1 C ( -22 to 356 F ) -15 to 6 C ( 5 to 1 F ) Working See Figure 2 1 to 3 C ( 5 to 572 F ) 1 to 6 C ( 5 to 1 F ) -2 to 12 C ( - to 2 F ) -1 to 6 C ( 1 to 1 F ) 51 kpa abs or more {3 mmhg abs} -5 to 1 C ( -5 to 212 F ) - to 6 C ( - to 1 F ) Vacuum not allowed Specific gravity * to *1: See Figure 2 Working Pressure and Process Temperature. *2: This ambient temperature is the transmitter ambient temperature. *3: Approimate values at a temperature of 25 C (77 F) Note: The differential transmitter should be installed at least 6 mm below the high (HP) process connection. However, this value (6 mm) may be affected by ambient temperature, operating, fill fluid or material of the wetted diaphragm. Contact YOKOGAWA when the transmitter can not be installed at least 6 mm below the HP process connection. GS 1C22H1-EN Jan. 27, 216-

4 Table 2-1. Accruacy, Ambient Temperature Effect, and Static Pressure Effect (With inear Output, As Percent of ) *1 *2 [For model EJA11W 3-inch flange, model EJA11N -inch flange and model EJA11Y, Wetted parts material code S] Capsule M, H Accuracy ±.2 % ± ( ) % For For < Ambient temperature effect *3 Zero shift Total shift *5 ± ( ) % / 5 C ± 1. % / 5 C ± ( ) % / 5 C For For < Static effect Zero shift Total shift **5 ±.1 % /.9 MPa {1 kgf/cm 2 } ± (.1 ) % /.9 MPa {1 kgf/cm 2 } ±.1 % /.9 MPa {1 kgf/cm 2 } ± (. +.1 ) % /.9 MPa {1 kgf/cm 2 } For For < For For < *1: is the highest value among the absolute value of the lower range value (LRV) and higher rangevalue (HRV), and the span value in a calibration range. Accuracy of square root output is as shown in Table. Percent of span = Percent of span *2: In case of 6 to 1 m. for capillary length, values of ambient temperature effect and static effect are twice that given in the table. *3: The ambient temperature effect specification applies to the range of to 6 C (32 to1 F). (Below C (32 F), value is three times that given in the table.) *: Values for measurement span.9 kpa {5 mmh 2 O} or below are estimated values. *5: Combined zero and span shift. F3E.ai Table 2-2. Accuracy, Ambient Temperature Effect, and Static Pressure Effect (With Linear Output, As Percent of ) *1 [For Model EJA11W 2-inch flange and EJA11N 3-inch flange] Capsule M, H Accuracy ±.2 % ± ( ) % For For < Ambient temperature effect *2 Zero shift Total shift * ± ( ) % / 5 C ± 1. % / 5 C ± (1. ) % / 5 C For For < Static effect Zero shift Total shift *3* ±.2 % /.9 MPa {1 kgf/cm 2 } ± (.2 ) % /.9 MPa {1 kgf/cm 2 } ±.25 % /.9 MPa {1 kgf/cm 2 } ± (.25 ) % /.9 MPa {1 kgf/cm 2 } For For < For For < *1: is the highest value among the absolute value of the lower range value (LRV) and higher range value (HRV), and the span value in a calibration range. Accuracy of square root output is as shown in Table. Percent of span = Percent of span *2: The ambient temperature effect specification applies to the range of to 6 C (32 to 1 F). (Below C (32 F), value is three times that given in the table.) *3: Values for measurement span.9 kpa {5 mmh 2 O} or below are estimated values. *: Combined zero and span shift. FE.ai GS 1C22H1-EN Jan. 27, 216-

5 5 Table 2-3. Accuracy, Ambient Temperature Effect, and Static Pressure Effect (With Linear Output, As Percent of ) *1 [For Model EJA11W wetted part material code H, T and U] Capsule M, H Accuracy ±.2 % ± ( ) % For For < Ambient temperature effect *2 Zero shift Total shift * ± ( ) % / 5 C ± 2. % / 5 C ± ( ) % / 5 C For For < Static effect Zero shift Total shift *3* ±.3 % /.9 MPa {1 kgf/cm 2 } ± (.3 ) % /.9 MPa {1 kgf/cm 2 } ±. % /.9 MPa {1 kgf/cm 2 } ± ( ) % /.9 MPa {1 kgf/cm 2 } For For < For For < *1: is the highest value among the absolute value of the lower range value (LRV) and higher range value (HRV), and the span value in a calibration range. Accuracy of square root output is as shown in Table. Percent of span = Percent of span *2: The ambient temperature effect specification applies to the range of to 6 C (32 to 1 F). (Below C (32 F), value is three times that given in the table.) *3: Values for measurement span.9 kpa {5 mmh 2 O} or below are estimated values. *: Combined zero and span shift. F5E.ai Table 3. Value of Capsule M H 2 kpa {2 mmh2o} 1 kpa {1 kgf/cm 2 } Table. Accuracy for Square Root Output Square Root Output Accuracy 5 % or greater Same as accuracy for linear output 5 % down to linear output 5 ( ) dropout point accuracy (square root output [%]) F6E.ai GS 1C22H1-EN Jan. 27, 216-

6 6 MODEL AND SUFFIX CODES MODEL EJA11W [Flange size : 3-inch ( mm)] Model Suffi Codes Description EJA11W Diaphragm sealed differential transmitter (Flush diaphragm type) Output Signal -D E F G Measurement span (capsule) M H Wetted parts material *1 S H # T U rating size / material Cover flange bolts material Fill fluid J J J A A A D D D P P P D E F A B A * B C * D * E to 2 ma DC with digital communication (BRAIN protocol) to 2 ma DC with digital communication (HART protocol, refer to GS 1C22T1-EN) Digital communication (FOUNDATION Fieldbus protocol, refer to GS 1C22T2-EN) Digital communication (PROFIBUS PA protocol, refer to GS 1C22T3-EN) 2.5 to 1 kpa {25 to 1 mmh2o}{1 to inh2o}{25 to 1 mbar} 25 to 5 kpa {.25 to 5 kgf/cm 2 }{1 to 2 inh2o}{25 to 5 mbar} [Diaphragm] [Others] JIS SUS316L JIS SUS316L *6 Hastelloy C-276 *7 Hastelloy C-276 *7 Tantalum Tantalum Titanium Titanium JIS 1K JIS 2K JIS K ANSI Class 15 ANSI Class 3 ANSI Class 6 DIN PN1/16 DIN PN25/ DIN PN6 JPI Class 15 JPI Class 3 JPI Class 6 3-inch ( mm) / JIS S25C 3-inch ( mm) / JIS SUS3 * 3-inch ( mm) / JIS SUS316 *9 JIS SCM35 JIS SUS63 [Process temp.] [Ambient temp.] For general use (silicone oil) -1 to 25 C -1 to 6 C For general use (silicone oil) -3 to 1 C -15 to 6 C For high temperature use (silicone oil) 1 to 3 C 1 to 6 C For oil-prohibited use (fluorinated oil) -2 to 12 C -1 to 6 C For low temperature use (ethylene glycol) -5 to 1 C - to 6 C A Always A Capillary length (m) * Specify capillary length from 1 to 1 m in. (Eample for 2 m: 2) Installation Horizontal impulse piping type, left side high Electrical connection A C D Integral indicator D E N Mounting bracket A..... B..... J..... N..... Optional codes / Optional specification G1/2 female, one electrical connection 1/2 NPT female, two electrical connections without blind plug Pg 13.5 female, two electrical connections without blind plug M2 female, two electrical connections without blind plug G1/2 female, two electrical connections and a blind plug 1/2 NPT female, two electrical connections and a blind plug Pg 13.5 female, two electrical connections and a blind plug M2 female, two electrical connections and a blind plug G1/2 female, two electrical connections and a SUS316 blind plug 1/2 NPT female, two electrical connections and a SUS316 blind plug M2 female, two electrical connections and a SUS316 blind plug Digital indicator Digital indicator with the range setting switch *1 JIS SECC 2-inch pipe mounting (flat type) JIS SUS3 2-inch pipe mounting (flat type) JIS SUS316 2-inch pipe mounting (flat type) The marks indicate the most typical selection for each specification. Eample: EJA11W-DMSA1DA-AA2-92NA/ The # marks indicate the construction materials conform to NACE material recommendations per MR1-75. For the use of SUS316 material, there may be certain limitations for and temperature. Please refer to NACE standards for details. GS 1C22H1-EN Jan. 27, 216-

7 7 *1: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 C [32 F] or above). Contact Yokogawa for detailed information of the wetted parts material. *2: In case of Wetted parts material code T (Tantalum), the process temperature limit is -1 to 2 C. *3: Wetted parts material code T (Tantalum) cannot be applied. *: Even in case where Fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify Optional code K1 or K5. *5: In case of Wetted parts material code H (Hastelloy C), T (Tantalum), and U (Titanium) or Fill fluid code C (for high temperature use), specify capillary length from 1 to 5 m. *6: JIS SUS316L or ASTM grade 316L. *7: Hastelloy C-276 or ASTM N1276. *: JIS SUS3 or ASTM grade 3. Forged version may be used. *9: JIS SUS316 or ASTM grade 316. Forged version may be used. *1: Not applicable for Output signal code F and G. GS 1C22H1-EN Jan. 27, 216-

8 MODEL EJA11W [Flange size : 2-inch (5mm)] Model Suffi Codes Description EJA11W Diaphragm sealed differential transmitter (Flush diaphragm type) Output Signal -D E F G Measurement span (capsule) M H Wetted parts material *1 S rating size / material Cover flange bolts material Fill fluid J J J A A A D D D P P P A B C A B A B to 2 ma DC with digital communication (BRAIN protocol) to 2 ma DC with digital communication (HART protocol, refer to GS 1C22T1-EN) Digital communication (FOUNDATION Fieldbus protocol, refer to GS 1C22T2-EN) Digital communication (PROFIBUS PA protocol, refer to GS 1C22T3-EN) 2.5 to 1 kpa {25 to 1 mmh2o}{1 to inh2o}{25 to 1 mbar} 25 to 5 kpa {.25 to 5 kgf/cm 2 }{1 to 2 inh2o}{25 to 5 mbar} [Diaphragm] [Others] JIS SUS316L JIS SUS316L *2 JIS 1K JIS 2K JIS K ANSI Class 15 ANSI Class 3 ANSI Class 6 DIN PN1/16 DIN PN25/ DIN PN6 JPI Class 15 JPI Class 3 JPI Class 6 2-inch (5 mm) / JIS S25C 2-inch (5 mm) / JIS SUS3 *3 2-inch (5 mm) / JIS SUS316 * JIS SCM35 JIS SUS63 [Process temp.] [Ambient temp.] For general use (silicone oil) -1 to 25 C -1 to 6 C For general use (silicone oil) -3 to 1 C -15 to 6 C A Always A Capillary length (m) Specify capillary length from 1 to 5 m in. (Eample for 2 m: 2) Installation Horizontal impulse piping type, left side high Electrical connection A C D Integral indicator D E N Mounting bracket A..... B..... J..... N..... Optional codes / Optional specification G1/2 female, one electrical connection 1/2 NPT female, two electrical connections without blind plug Pg 13.5 female, two electrical connections without blind plug M2 female, two electrical connections without blind plug G1/2 female, two electrical connections and a blind plug 1/2 NPT female, two electrical connections and a blind plug Pg 13.5 female, two electrical connections and a blind plug M2 female, two electrical connections and a blind plug G1/2 female, two electrical connections and a SUS316 blind plug 1/2 NPT female, two electrical connections and a SUS316 blind plug M2 female, two electrical connections and a SUS316 blind plug Digital indicator Digital indicator with the range setting switch *5 JIS SECC 2-inch pipe mounting (flat type) JIS SUS3 2-inch pipe mounting (flat type) JIS SUS316 2-inch pipe mounting (flat type) The marks indicate the most typical selection for each specification. Eample: EJA11W-DMSA1AA-AA2-92NA/ *1: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 C [32 F] or above). Contact Yokogawa for detailed information of the wetted parts material. *2: JIS SUS316L or ASTM grade 316L. *3: JIS SUS3 or ASTM grade 3. Forged version may be used. *: JIS SUS316 or ASTM grade 316. Forged version may be used. *5: Not applicable for Output signal code F and G. GS 1C22H1-EN Jan. 27, 216-

9 9 MODEL EJA11N [Flange size : -inch (1 mm)] Model Suffi Codes Description EJA11N Diaphragm sealed differential transmitter (Etended diaphragm type) Output Signal Measurement span (capsule) -D E F G M H Wetted parts material *1 S rating Diaphragm etension length (X2) size / material Cover flange bolts material Fill fluid J J A A D D G H J A B A B C D * E to 2 ma DC with digital communication (BRAIN protocol) to 2 ma DC with digital communication (HART protocol, refer to GS 1C22T1-EN) Digital communication (FOUNDATION Fieldbus protocol, refer to GS 1C22T2-EN) Digital communication (PROFIBUS PA protocol, refer to GS 1C22T3-EN) 2.5 to 1 kpa {25 to 1 mmh2o}{1 to inh2o}{25 to 1 mbar} 25 to 5 kpa {.25 to 5 kgf/cm 2 }{1 to 2 inh2o}{25 to 5 mbar} [Diaphragm] [Pipe] [Others] JIS SUS316L JIS SUS316 JIS SUS316 *2 JIS 1K JIS 2K ANSI Class 15 P1.... JPI Class 15 ANSI Class 3 P2.... JPI Class 3 DIN PN1/16 DIN PN25/ X2 = 5 mm X2 = 1 mm X2 = 15 mm -inch (1 mm) / JIS S25C -inch (1 mm) / JIS SUS3 *3 -inch (1 mm) / JIS SUS316 * JIS SCM35 JIS SUS63 [Process temp.] [Ambient temp.] For general use (silicone oil) -1 to 25 C -1 to 6 C For general use (silicone oil) -3 to 1 C -15 to 6 C For high temperature use (silicone oil) 1 to 3 C 1 to 6 C For oil-prohibited use (fluorinated oil) -2 to 12 C -1 to 6 C For low temperature use (ethylene glycol) -5 to 1 C - to 6 C B Always B Capillary length (m) *6* Specify capillary length from 1 to 1 m in. (Eample for 2 m : 2) Installation Horizontal impulse piping type, left side high Electrical connection A C D Integral indicator D E N Mounting bracket A..... B..... J..... N..... Optional codes / Optional specification G1/2 female, one electrical connection 1/2 NPT female, two electrical connections without blind plug Pg 13.5 female, two electrical connections without blind plug M2 female, two electrical connections without blind plug G1/2 female, two electrical connections and a blind plug 1/2 NPT female, two electrical connections and a blind plug Pg 13.5 female, two electrical connections and a blind plug M2 female, two electrical connections and a blind plug G1/2 female, two electrical connections and a SUS316 blind plug 1/2 NPT female, two electrical connections and a SUS316 blind plug M2 female, two electrical connections and a SUS316 blind plug Digital indicator Digital indicator with the range setting switch * JIS SECC 2-inch pipe mounting (flat type) JIS SUS3 2-inch pipe mounting (flat type) JIS SUS316 2-inch pipe mounting (flat type) The marks indicate the most typical selection for each specification. Eample: EJA11N-DMSA12GA-AB2-92NA/ *1: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 C [32 F] or above). Contact Yokogawa for detailed information of the wetted parts material. *2: JIS SUS316 or ASTM grade 316. *3: JIS SUS3 or ASTM grade 3. Forged version may be used. *: JIS SUS316 or ASTM grade 316. Forged version may be used. *5: Even in case where Fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify Optional code K1 or K5. *6: In case of Fill fluid code C (for high temperature use), specify capillary length from 1 to 5 m. *7: The specified capillary length includes the diaphragm etension length(x2) and the flange thickness(t). *: Not applicable for Output signal code F and G. GS 1C22H1-EN Jan. 27, 216-

10 1 MODEL EJA11N [Flange size : 3-inch ( mm)] Model Suffi Codes Description EJA11N Diaphragm sealed differential transmitter (Etended diaphragm type) Output Signal Measurement span (capsule) -D E F G M H Wetted parts material *1 S rating Diaphragm etension length (X2) size / material Cover flange bolts material Fill fluid J J A A D D P P D E F A B A B to 2 ma DC with digital communication (BRAIN protocol) to 2 ma DC with digital communication (HART protocol, refer to GS 1C22T1-EN) Digital communication (FOUNDATION Fieldbus protocol, refer to GS 1C22T2-EN) Digital communication (PROFIBUS PA protocol, refer to GS 1C22T3-EN) 2.5 to 1 kpa {25 to 1 mmh2o}{1 to inh2o}{25 to 1 mbar} 25 to 5 kpa {.25 to 5 kgf/cm 2 }{1 to 2 inh2o}{25 to 5 mbar} [Diaphragm] [Pipe] [Others] JIS SUS316L JIS SUS316 JIS SUS316 *2 JIS 1K JIS 2K ANSI Class 15 ANSI Class 3 DIN PN1/16 DIN PN25/ JPI Class 15 JPI Class 3 X2 = 5 mm X2 = 1 mm X2 = 15 mm 3-inch ( mm) / JIS S25C 3-inch ( mm) / JIS SUS3 *3 3-inch ( mm) / JIS SUS316 * JIS SCM35 JIS SUS63 [Process temp.] [Ambient temp.] For general use (silicone oil) -1 to 25 C -1 to 6 C For general use (silicone oil) -3 to 1 C -15 to 6 C B Always B Capillary length (m) * Specify capillary length from 1 to 5 m in. (Eample for 2 m : 2) Installation Horizontal impulse piping type, left side high Electrical connection A C D Integral indicator D E N Mounting bracket A..... B..... J..... N..... Optional codes / Optional specification G1/2 female, one electrical connection 1/2 NPT female, two electrical connections without blind plug Pg 13.5 female, two electrical connections without blind plug M2 female, two electrical connections without blind plug G1/2 female, two electrical connections and a blind plug 1/2 NPT female, two electrical connections and a blind plug Pg 13.5 female, two electrical connections and a blind plug M2 female, two electrical connections and a blind plug G1/2 female, two electrical connections and a SUS316 blind plug 1/2 NPT female, two electrical connections and a SUS316 blind plug M2 female, two electrical connections and a SUS316 blind plug Digital indicator Digital indicator with the range setting switch *6 JIS SECC 2-inch pipe mounting (flat type) JIS SUS3 2-inch pipe mounting (flat type) JIS SUS316 2-inch pipe mounting (flat type) The marks indicate the most typical selection for each specification. Eample: EJA11N-DMSA12DA-AB2-92NA/ *1: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 C [32 F] or above). Contact Yokogawa for detailed information of the wetted parts material. *2: JIS SUS316 or ASTM grade 316. *3: JIS SUS3 or ASTM grade 3. Forged version may be used. *: JIS SUS316 or ASTM grade 316. Forged version may be used. *5: The specified capillary length includes the diaphragm etension length(x2) and the flange thickness(t). *6: Not applicable for Output signal code F and G. GS 1C22H1-EN Jan. 27, 216-

11 11 MODEL EJA11Y Model Suffi Codes Description EJA11Y Diaphragm sealed differential transmitter (Combination of etended diaphragm and flush diaphragm type) Output Signal Measurement span (capsule) High side (etended diaphragmtype) wetted parts material *1 rating Diaphragm etension length (X2) size / material Cover flange bolts material Fill fluid -D E F G M H S * J J A A D D P P P Q R A B A B C D * E to 2 ma DC with digital communication (BRAIN protocol) to 2 ma DC with digital communication (HART protocol, refer to GS 1C22T1-EN) Digital communication (FOUNDATION Fieldbus protocol, refer to GS 1C22T2-EN) Digital communication (PROFIBUS PA protocol, refer to GS 1C22T3-EN) 2.5 to 1 kpa {25 to 1 mmh2o}{1 to inh2o}{25 to 1 mbar} 25 to 5 kpa {.25 to 5 kgf/cm 2 }{1 to 2 inh2o}{25 to 5 mbar} [Diaphragm] [Pipe] [Others] JIS SUS316L JIS SUS316 JIS SUS316 *3 JIS 1K JIS 2K ANSI Class 15 ANSI Class 3 DIN PN1/16 DIN PN25/ JPI Class 15 JPI Class 3 X2 = 5 mm X2 = 1 mm X2 = 15 mm High side -inch (1 mm) / JIS S25C Low side 3-inch ( mm) / JIS S25C High side -inch (1 mm) / JIS SUS3 * Low side 3-inch ( mm) / JIS SUS3 *5 High side -inch (1 mm) / JIS SUS316 * Low side 3-inch ( mm) / JIS SUS316 *5 JIS SCM35 JIS SUS63 [Process temp.] [Ambient temp.] For general use (silicone oil) -1 to 25 C -1 to 6 C For general use (silicone oil) -3 to 1 C -15 to 6 C For high temperature use (silicone oil) 1 to 3 C 1 to 6 C For oil-prohibited use (fluorinated oil) -2 to 12 C -1 to 6 C For low temperature use (ethylene glycol) -5 to 1 C - to 6 C C Always C Capillary length (m) *7* Specify capillary length from 1 to 1 m in. (Eample for 2 m : 2) Installation Horizontal impulse piping type, left side high Electrical connection A C D Integral indicator D E N Mounting bracket A..... B..... J..... N..... Optional codes / Optional specification G1/2 female, one electrical connection 1/2 NPT female, two electrical connections without blind plug Pg 13.5 female, two electrical connections without blind plug M2 female, two electrical connections without blind plug G1/2 female, two electrical connections and a blind plug 1/2 NPT female, two electrical connections and a blind plug Pg 13.5 female, two electrical connections and a blind plug M2 female, two electrical connections and a blind plug G1/2 female, two electrical connections and a SUS316 blind plug 1/2 NPT female, two electrical connections and a SUS316 blind plug M2 female, two electrical connections and a SUS316 blind plug Digital indicator Digital indicator with the range setting switch *9 JIS SECC 2-inch pipe mounting (flat type) JIS SUS3 2-inch pipe mounting (flat type) JIS SUS316 2-inch pipe mounting (flat type) The marks indicate the most typical selection for each specification. Eample: EJA11Y-DMSA12PA-AC2-92NA/ GS 1C22H1-EN Jan. 27, 216-

12 12 *1: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 C [32 F] or above). Contact Yokogawa for detailed information of the wetted parts material. *2: Low side (Flush diaphragm) wetted parts material: Diaphragm; SUS316L, Others; JIS SUS316L or ASTM grade 316L. *3: JIS SUS316 or ASTM grade 316. *: JIS SUS3 or ASTM grade 3. Forged version may be used. *5: JIS SUS316 or ASTM grade 316. Forged version may be used. *6: Even in case where Fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify Optional code K1 or K5. *7: In case of Fill fluid code C (for high temperature use), specify capillary length from 1 to 5 m. *: The specified capillary length of high side(etended diaphragm side) includes the diaphragm etension length(x2) and the flange thickness(t). *9: Not applicable for Output signal code F and G. OPTIONAL SPECIFICATIONS (For Eplosion Protected type ) For FOUNDATION Fieldbus eplosion protected type, see GS 1C22T2-EN. For PROFIBUS PA eplosion protected type, see GS 1C22T3-EN. Factory Mutual (FM) Item Description Code FM Eplosionproof Approval *1 *3 * Applicable standard: FM36, FM3615, FM31, ANSI/NEMA25 Eplosionproof for Class I, Division 1, Groups B, C and D Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G Hazardous (classified) locations, indoors and outdoors (NEMA X) Division 2, SEALS NOT REQUIRED, Temp. Class: T6 Amb. Temp.: to 6 C ( to 1 F) FM Intrinsically safe Approval *1 *3 * Applicable standard: FM36, FM361, FM3611, FM31, ANSI/NEMA25 Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G and Class III, Division 1 Hazardous Locations. Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2, Groups E, F & G, and Class III, Division 1 Hazardous Locations. Enclosure: NEMA X, Temp. Class: T, Amb. Temp.: to 6 C ( to 1 F) Intrinsically Safe Apparatus Parameters [Groups A, B, C, D, E, F and G] Vma=3 V, Ima=165 ma, Pma=.9 W, Ci=22.5 nf, Li=73 µh [Groups C, D, E, F and G] Vma=3 V, Ima=225 ma, Pma=.9 W, Ci=22.5 nf, Li=73 µh Combined FF1 and FS1 *1 *3 * FU1 FF1 FS1 GS 1C22H1-EN Jan. 27, 216-

13 13 Item Description Code Canadian Standards Association (CSA) CSA Eplosionproof Approval *1 *3 * Applicable standard: C22.2 No., No.., No. 25, No. 3, No. 9, No. 12 Certificate: 1959 Eplosionproof for Class I, Division 1, Groups B, C and D Dustignitionproof for Class II/III, Division 1, Groups E, F and G Division2 SEALS NOT REQUIRED, Temp. Class: T, T5, T6 Encl Type Ma. Process Temp.: T; 12 C (2 F), T5; 1 C (212 F), T6; 5 C (15 F) Amb. Temp.: to C ( to 176 F) Process Sealing Certification Dual Seal Certified by CSA to the requirement of ANSI/ISA No additional sealing required. Primary seal failure annunciation: at the zero adjustment screw CSA Intrinsically safe Approval *1 *3 * Applicable standard: C22.2 No., No.., No. 25, No. 3, No. 9, No. 12, No. 157, No. 213 Certificate: 1533 Class I, Groups A, B, C and D Class II and III, Groups E, F and G Encl Type, Temp. Class: T, Amb. Temp.: to 6 C ( to 1 F) Vma=3 V, Ima=165 ma, Pma=.9 W, Ci=22.5 nf, Li=73 µh Process Sealing Certification Dual Seal Certified by CSA to the requirement of ANSI/ISA No additional sealing required. Primary seal failure annunciation: at the zero adjustment screw Combined CF1 and CS1 *1 *3 * CU1 IECE IECE Intrinsically safe, type n and Flameproof Approval *3 * *9 Intrinsically safe and type n Applicable Standard: IEC 679-:2, IEC :1999, IEC :25, IEC :25 Certificate: IECE KEM 6.7X E ia IIC T, E nl IIC T Enclosure: IP67 Amb. Temp.: to 6 C ( to 1 F), Ma. Process Temp.: 12 C (2 F) Electrical Parameters: [E ia] Ui=3 V, Ii=165 ma, Pi=.9 W, Ci=22.5 nf, Li=73 µh [E nl] Ui=3 V, Ci=22.5 nf, Li=73 µh Flameproof Applicable Standard: IEC 679-:2, IEC679-1:23 Certificate: IECE KEM 6.5 E d IIC T6...T Enclosure: IP67 Ma.Process Temp.: T;12 C (2 F), T5;1 C (212 F), T6; 5 C (15 F) Amb.Temp.: to 75 C ( to 167 F) for T, to C ( to 176 F) for T5, to 75 C ( to 167 F) for T6 TIIS certification TIIS Flameproof Approval, E do IIC TX *3 *5 *7 * *1 Certificate: TC15296 (Without integral indicator), TC15297 (With integral indicator) Amb. Temp.: 2 to 6 C, Process Temp.: 2 to 12 C TIIS Intrinsically safe Approval, E ia IIC T *6 * Certificate: TC1632 Amb. Temp.: 2 to 6 C, Process Temp.: 2 to 12 C Attached flameproof packing adapter *5 Electrical connection: G1/2 female Applicable cable: O. D. to 12 mm CF1 CS1 SU2 JF3 JS3 1 pc. G11 2 pcs. G12 *1: Applicable for Electrical connection code 2, 7 and C (1/2 NPT female). *2: (Not used) *3: Applicable for Output signal code D and E. For intrinsically safe approval, use the safety barrier certified by the testing laboratories (BARD- is not applicable). *: Lower limit of ambient temperature is 15 C (5 F) when /HE is specified. *5: If cable wiring is to be used to a TIIS flameproof type transmitter, add the YOKOGAWA-assured flameproof packing adapter. *6: Applicable for Output signal code D. See <Safety Barrier for TIIS Intrinsically Safe Type>. *7: In case that the ambient temperature eceeds 5 C or that the ambient temperature eceeds 5 C with the process temperature of 9 C or above, use heat-resistant cables with maimum allowable temperature of 75 C or above. *: TIIS (The Technology Institution of Industrial Safety) Certification is a new notation for the eplosionproof approval in Japan instead of JIS. *9: Applicable for Electrical connection code 2,, 7, C and D (1/2 NPT and M2 female). *1: Not applicable for Electrical connection code A, C and D. GS 1C22H1-EN Jan. 27, 216-

14 1 OPTIONAL SPECIFICATIONS Item Description Code Painting *1 Color change Amplifier cover only P Amplifier cover and terminal cover, Munsell 7.5 R/1 PR Coating change Epoy resin-baked coating *11 X1 316 SST eterior parts Eterior parts on the amplifier housing (name plates, tag plate, zero-adjustment screw, stopper screw) will become 316 SST *12 HC Fluoro-rubber O-ring All O-rings of amplifier housing. Lower limit of ambient temperature: 15 C (5 F) *13 HE Lightning protector Transmitter power supply voltage: 1.5 to 32 V DC ( 1.5 to 2 V DC for TIIS intrinsically safe type, 1.5 to 3 V DC for intrinsically safe type other than TIIS, or 9 to 32 V DC for Fieldbus communicaiton type.) A Allowable current: Ma. 6 A ( 1 µs ), Repeating 1 A ( 1 µs ) 1 times Oil-prohibited use Degrease cleansing treatment K1 Oil-prohibited use with Degrease cleansing and dehydrating treatment dehydrating treatment K5 Calibration units *1 P calibration (psi unit) D1 bar calibration (bar unit) (See Table 5. on page 15) D3 M calibration (kgf/cm 2 unit) D Sealing treatment to JIS SUS63 nuts Sealant(liquid silicone rubber) is coated on JIS SUS63 cover flange mounting nuts against stress corrosion cracking. No serration *2 No serration work on the flange gasket surface (for ANSI flange only ) Q Teflon film *3 Diaphragm protection from sticky process fluid by FEP Teflon film attached with fluorinated oil. Operation range: 2 to 15 C, to 2 MPa(Not applicable for vacuum service). T Operating temperature Adjusting range : C to Maimum temperature of specified fill fluid correction * R Capillary without PVC sheaths When ambient temperature eceeds 1 C, or use of PVC is prohibited V Fast response * Update time:.125 sec Amplifier assembly damping time constant:.1 to 6 sec in 9 increments. F1 Response time (with min. damping time constant): ma..5 sec (ecluding diaphragm seal units) Failure alarm down-scale *5 Output status at CPU failure and hardware error is 5%, 3.2 ma or less. C1 NAMUR NE3 compliant *5 *9 Output signal limits: 3. ma to 2.5 ma Failure alarm down-scale: output status at CPU failure and hardware error is 5%, 3.2 ma or less. Failure alarm up-scale: output status at CPU failure and hardware error is 11%, 21.6 ma or more. Data configuration at factory Description into Descriptor parameter of HART protocol CA Stainless steel amplifier housing *6 Amplifier housing material: JIS SCS1A stainless steel (equivalent to JIS SUS316 cast stainless steel or ASTM CF-M) model) Gold-plate *7 Inside of isolating diaphragms(fill fluid side) are gold plated, effective for hydrogen permeation. A1 Wired tag plate 3SST tag plate wired onto transmitter N Mill Certificate, Block For model EJA11W M5, Block, Pipe, Base For model EJA11N M6 High side:, Block, Pipe, Base Low side:, Block For model EJA11Y M7 Pressure test/ Leak test (Flange rating) (Test ) (Applicable Certificate * 1 JIS 1K 2 MPa {2 kgf/cm 2 } T31 All EJA11 JIS 2K 5 MPa {5 kgf/cm 2 } T32 Nitrogen ( N2 JIS K 1 MPa {1 kgf/cm 2 } EJA11W ) Gas *15 T33 Retention time: ANSI/JPI Class 15 3 MPa {29. kgf/cm 2 } All EJA11 1 minutes T36 ANSI/JPI Class MPa {77 kgf/cm 2 } EJA11W T37 ANSI/JPI Class 3 7 MPa {7 kgf/cm 2 } EJA11N/EJA11Y T3 ANSI/JPI Class 6 1 MPa {1 kgf/cm 2 } EJA11W T39 Y C2 C3 E1 GS 1C22H1-EN Jan. 27, 216-

15 15 *1: The unit of MWP (Ma. working ) on name plate of a housing is the same unit as specified by Option code D1, D3, and D. *2: This item cannot be applied to model EJA11W Wetted part material code H, T, or U, whose gasket contact surface are not serrated as standard specifications. *3: Teflon film can only be specified for model EJA11W. *: Specify the process operating temperature for zero correction. Eample: Zero correction by process temperature 9 C. *5: Applicable for Output signal code D and E. The hardware error indicates faulty amplifier or capsule. When combining with Option code F1, output status for down-scale is 2.5%, 3.6 ma DC or less. *6: Applicable for Electrical connection code 2, 3,, A, C and D. Not applicable for Option code P, X1, and JF3. *7: Applicable for Wetted parts material code S and H. *: Applicable for Output signal code D and E. Write protection switch is attached for Output code E. Not applicable for Integral indicator code E. *9: Not applicable for Option code C1. *1: Standard polyurethan painting can be used in acid atmosphere, whereas the epoy resin-baked coating (Option code X1) can be used in alkaline atmosphere. Anti-corrosion coating, the combination of polyurethan and epoy resin-baked coating, is available by special order as sea water, alkaline, and acid resistant. *11: Not applicable for color change option. *12: 316 or 316L SST. The specification is included in option code /E1. Not applicable with option code /JF3. *13: Not applicable with option code /JF3. *1: The unit on the certificate is always MPa regardless of selection of option code D1, D3, or D. *15: Pure nitrogen gas is used for oil-prohibited use (Option code K1 and K5). Table 5. Calibration Units Measurement Span and Range M H Optional Code D1 ( psi Unit ) D3 ( bar Unit ) D ( kgf/cm 2 Unit ) Span 1 to inh2o 25 to 1 mbar 25 to 1 mmh2o Range - to inh2o -1 to 1 mbar -1 to 1 mmh2o Span 1 to 2 inh2o 25 to 5 mbar.25 to 5 kgf/cm 2 Range -2 to 2 inh2o -5 to 5 mbar -5 to 5 kgf/cm 2 GS 1C22H1-EN Jan. 27, 216-

16 16 DIMENSIONS Model EJA11W ød *1 25 (.9) f Unit : mm (appro.inch) t 3 (1.3) ød øc øg Eternal indicator conduit connection (Optional) 1(5.51) 9(3.7) Conduit connection n- øh High side 11 (.33) 9 (.35) Wetted parts material code U (Titanium) Low side Internal indicator (Optional) 197(7.76) ø7 (3.7) Terminal side 16(5.75) 333(13.11) 12 (.) 92 (3.62) Shrouding bolt *2 Zero adjustment Ground terminal 7 (1.5) 2-inch pipe (O.D. 6.5mm) *1: Indicates inside diameter of gasket contact surface. *2: Applicable only for ATEX, IECE, and TIIS Flameproof type. size : 3 inch ( mm) Flange Rating JIS 1K JIS 2K JIS K ANSI Class 15 ød 15(7.2) 2(7.7) 21(.27) 19.5(7.5) øc 15(5.91) 16(6.3) 17(6.69) 152.(6) øg 13(5.12) 13(5.12) 13(5.12) 13(5.12) ANSI Class 3 ANSI Class (.25) 16.1(6.62) 29.6(.25) 16.1(6.62) 13(5.12) 13(5.12) JPI Class 15 JPI Class 3 JPI Class 6 DIN PN 1/16 DIN PN 25/ DIN PN 6 19(7.) 21(.27) 21(.27) 2(7.7) 2(7.7) 215(.6) 152.(6) 16.1(6.62) 16.1(6.62) 16(6.3) 16(6.3) 17(6.69) 13(5.12) 13(5.12) 13(5.12) 13(5.12) 13(5.12) 13(5.12) size : 2 inch (5 mm) ød 9(3.5) 9(3.5) 9(3.5) 9(3.5) 9(3.5) 9(3.5) 9(3.5) 9(3.5) 9(3.5) 9(3.5) 9(3.5) 9(3.5) t 1(.71) 22(.7) 32(1.26) 23.9(.9) 2.5(1.12) 3.2(1.5) 2(.9) 2.5(1.12) 3.(1.51) 2(.79) 2(.9) 2(1.1) Flange Rating JIS 1K JIS 2K JIS K ød 155(6.1) 155(6.1) 165(6.5) øc 12(.72) 12(.72) 13(5.12) øg 1(3.9) 1(3.9) 1(3.9) ød 61(2.) 61(2.) 61(2.) t 16(.63) 1(.71) 26(1.2) ANSI Class 15 ANSI Class 3 ANSI Class (6.) 12.7(.75) 165.1(6.5) 127.(5.) 165.1(6.5) 127.(5.) 1(3.9) 1(3.9) 1(3.9) 61(2.) 61(2.) 61(2.) 19.1(.75) 22.(.) 31.(1.25) JPI Class 15 JPI Class 3 JPI Class 6 DIN PN 1/16 DIN PN 25/ DIN PN 6 152(6.1) 165(6.5) 165(6.5) 165(6.5) 165(6.5) 1(7.9) 12.6(.75) 127.(5.) 127.(5.) 125(.92) 125(.92) 135(5.31) 1(3.9) 1(3.9) 1(3.9) 1(3.9) 1(3.9) 1(3.9) 61(2.) 61(2.) 61(2.) 61(2.) 61(2.) 61(2.) 19.5(.77) 22.5(.9) 31.9(1.26) 1(.71) 2(.7) 26(1.2) * In case where process flange material is JIS S25C, value of f is. Mounting bracket (Flat-type, Optional) f * 1.6(.6) 1.6(.6) 6.(.25) 1.6(.6) 1.6(.6) 6.(.25) f * 1.6(.6) 1.6(.6) 6.(.25) 1.6(.6) 1.6(.6) 6.(.25) n n øh 19(.75) 23(.91) 23(.91) 19.1(.75) 22.(.) 22.(.) 19(.75) 22(.7) 22(.7) 1(.71) 1(.71) 22(.7) øh 19(.75) 19(.75) 19(.75) 19.1(.75) 19.1(.75) 19.1(.75) 19(.75) 19(.75) 19(.75) 1(.71) 1(.71) 22(.7) F7E.ai GS 1C22H1-EN Jan. 27, 216-

17 17 Model EJA11N Unit : mm (appro.inch) ød øc øg 1(.55) X2 øa t f ø3 (1.1) 12 (.72) n-øh Eternal indicator conduit connection (Optional) 1(5.51) 9(3.7) Conduit connection 11 (.33) 9 (.35) Low side Internal indicator (Optional) 197(7.76) ø7 (3.7) Terminal side 16(5.75) 333(13.11) 12 (.) 92 (3.62) Shrouding bolt *1 Zero adjustment Ground terminal 7 (1.5) 2-inch pipe (O.D. 6.5mm) Mounting bracket (Flat-type, Optional) *1: Applicable only for ATEX, IECE, and TIIS Flameproof type. Diaphramg etension length code 2 : X 2 = 5 mm (2 inch) : X 2 = 1 mm ( inch) 6 : X 2 = 15 mm (6 inch) size : inch (1 mm) Flange Rating ød øc øg øa t f * n øh JIS 1K 21(.72) 175(6.9) 155(6.1) 96±.5(3.7) 1(.71) 19(.75) JIS 2K 225(.6) 15(7.2) 155(6.1) 96±.5(3.7) 2(.9) 23(.91) ANSI Class (9.) 19.5(7.5) 155(6.1) 96±.5(3.7) 23.9(.9) 1.6(.6) 19.1(.75) ANSI Class 3 25(1.) 2.2(7.) 155(6.1) 96±.5(3.7) 31.(1.25) 1.6(.6) 22.(.) JPI Class (9.2) 19.5(7.5) 155(6.1) 96±.5(3.7) 2(.9) 1.6(.6) 19(.75) JPI Class 3 25(1.) 2.2(7.) 155(6.1) 96±.5(3.7) 32(1.26) 1.6(.6) 22(.7) DIN PN 1/16 22(.66) 1(7.9) 155(6.1) 96±.5(3.7) 2(.79) 1(.71) DIN PN 25/ 235(9.25) 19(7.) 155(6.1) 96±.5(3.7) 2(.9) 22(.7) size : 3 inch ( mm) Flange Rating ød øc øg øa t f * n øh JIS 1K 15(7.2) 15(5.91) 13(5.12) 71±.5(2.) 1(.71) 19(.75) JIS 2K 2(7.7) 16(6.3) 13(5.12) 71±.5(2.) 22(.7) 23(.91) ANSI Class (7.5) 152.(6) 13(5.12) 71±.5(2.) 23.9(.9) 1.6(.6) 19.1(.75) ANSI Class (.25) 16.1(6.62) 13(5.12) 71±.5(2.) 2.5(1.12) 1.6(.6) 22.(.) JPI Class 15 19(7.) 152.(6) 13(5.12) 71±.5(2.) 2(.9) 1.6(.6) 19(.75) JPI Class 3 21(.27) 16.1(6.62) 13(5.12) 71±.5(2.) 2.5(1.12) 1.6(.6) 22(.7) DIN PN 1/16 2(7.7) 16(6.3) 13(5.12) 71±.5(2.) 2(.79) 1(.71) DIN PN 25/ 2(7.7) 16(6.3) 13(5.12) 71±.5(2.) 2(.9) 1(.71) * In case where process flange material is JIS S25C, value of f is. FE.ai GS 1C22H1-EN Jan. 27, 216-

18 1 Model EJA11Y ød øc ø155 (6.1) 25 (.9) ø9 *1 (3.5) Unit : mm (appro.inch) t f ø96±.5 (3.7) X2 1 (.55) ø13 (5.12) øc ød 12 (.72) ø3 (1.1) f t n-øh 1 (5.51) 9 (3.7) High side n-øh 11 (.33) 9 (.35) Low side Eternal indicator conduit connection (Optional) Conduit connection Internal indicator (Optional) ø7 (3.7) Terminal side Shrouding bolt *2 12 (.) 333 (13.11) Zero adjustment Ground terminal 7 (1.5) Mounting bracket 2-inch pipe (Flat-type, Optional) (O.D. 6.5mm) (1.9) *1: Indicates inside diameter of gasket contact surface. *2: Applicable only for ATEX, IECE, and TIIS Flameproof type. High side size : inch (1 mm) Flange Rating ød øc t f * n øh JIS 1K 21(.72) 175(6.9) 1(.71) 19(.75) JIS 2K 225(.6) 15(7.2) 2(.9) 23(.91) ANSI Class (9.) 19.5(7.5) 23.9(.9) 1.6(.6) 19.1(.75) ANSI Class 3 25(1.) 2.2(7.) 31.(1.25) 1.6(.6) 22.(.) JPI Class (9.2) 19.5(7.5) 2(.9) 1.6(.6) 19(.75) JPI Class 3 25(1.) 2.2(7.) 32(1.26) 1.6(.6) 22(.7) DIN PN 1/16 22(.66) 1(7.9) 2(.79) 1(.71) DIN PN 25/ 235(9.25) 19(7.) 2(.9) 22(.7) Diaphramg etension length code 2 : X 2 = 5 mm (2 inch) : X 2 = 1 mm ( inch) 6 : X 2 = 15 mm (6 inch) Low side size :3 inch ( mm) Flange Rating JIS 1K JIS 2K ANSI Class 15 ANSI Class 3 JPI Class 15 JPI Class 3 DIN PN 1/16 DIN PN 25/ ød øc 15(7.2) 15(5.91) 2(7.7) 16(6.3) 19.5(7.5) 152.(6) 29.6(.25) 16.1(6.62) 19(7.) 152.(6) 21(.27) 16.1(6.62) 2(7.7) 16(6.3) 2(7.7) 16(6.3) t 1(.71) 22(.7) 23.9(.9) 2.5(1.12) 2(.9) 2.5(1.12) 2(.79) 2(.9) f * 1.6(.6) 1.6(.6) 1.6(.6) 1.6(.6) * In case where process flange material is JIS S25C, value of f is. n øh 19(.75) 23(.91) 19.1(.75) 22.(.) 19(.75) 22(.7) 1(.71) 1(.71) F9E.ai GS 1C22H1-EN Jan. 27, 216-

General Specifications

General Specifications General Specifications Model EJA3W and EJA3N Diaphragm Sealed Gauge Pressure Transmitters GS 1C22J3-E [Style: S2] Diaphragm seal is used to prevent process medium from entering directly into the pressure-sensing

More information

General Specifications

General Specifications General Specifications Model EJA120A Differential Pressure Transmitter GS 01C21B03-00E The high performance draft range differential transmitter model EJA120A outputs a 4 to 20 ma DC signal corresponding

More information

General Specifications

General Specifications General Specifications Model EJA440A Gauge Pressure Transmitter GS 01C21E02-00E The high performance gauge transmitter model EJA440A can be used to measure liquid, gas, or steam. It outputs a 4 to 20 ma

More information

General Specifications

General Specifications General Specifications GS 01C25J03-01EN EJX438A Diaphragm Sealed Gauge Pressure Transmitter [Style: S2] Diaphragm seal is used to prevent process medium form entering directly into the -sensing assembly

More information

General Specifications

General Specifications General Specifications GS 01C25J03-01EN EJX438A Diaphragm Sealed Gauge Pressure Transmitter [Style: S2] Diaphragm seal is used to prevent process medium form entering directly into the -sensing assembly

More information

General Specifications

General Specifications General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant

More information

General Specifications

General Specifications General Specifications EJX118A Diaphragm Sealed Differential Pressure Transmitter [Style: S2] Diaphragm seals are used to prevent process medium form entering directly into the -sensing assembly of the

More information

General Specifications

General Specifications General Specifications GS 1C25J3-1E EJX3A Diaphragm Sealed Gauge Pressure Transmitter Diaphragm seal is used to prevent process medium form entering directly into the pressure-sensing assembly of the pressure

More information

General Specifications

General Specifications General Specifications EJA120E Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJA120E features single crystal silicon resonant sensor and is suitable

More information

General Specifications

General Specifications General Specifications GS 01C25F01-01E EJX510A and EJX530A Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal

More information

General Specifications

General Specifications General Specifications GS 1C27H1-1EN EJX11B and EJX3B Diaphragm Sealed Differential Pressure and Gauge Pressure Transmitters Diaphragm seals are used to prevent process medium from entering directly into

More information

General Specifications

General Specifications General Specifications EJA110A Differential Pressure Transmitter The high performance differential transmitter model EJA110A can be used to measure liquid, gas, or steam flow as well as liquid level, density

More information

General Specifications

General Specifications General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant

More information

General Specifications

General Specifications General Specifications EJA310E Absolute Pressure Transmitter The high performance absolute transmitter EJA310E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or

More information

General Specifications

General Specifications General Specifications odel EJA130A Differential Pressure Transmitter GS 01C21B04-00E The high performance differential transmitter model EJA130A can be used to measure liquid, gas, or steam flow as well

More information

General Specifications

General Specifications General Specifications EJA120E Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJA120E features single crystal silicon resonant sensor and is suitable

More information

General Specifications

General Specifications General Specifications EJA440E Gauge Pressure Transmitter The high performance gauge transmitter EJA440E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam.

More information

General Specifications

General Specifications General Specifications EJA440E Gauge Pressure Transmitter The high performance gauge transmitter EJA440E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam.

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon

More information

General Specifications

General Specifications General Specifications EJX510A and EJX530A Absolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal silicon

More information

General Specifications

General Specifications General Specifications EJA130E Differential Pressure Transmitter The high performance differential transmitter EJA130E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to

More information

General Specifications

General Specifications General Specifications EJX510B and EJX530B Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitters EJX510B and EJX530B feature single crystal silicon resonant

More information

General Specifications

General Specifications General Specifications EJX120A Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJX120A features single crystal silicon resonant sensor and is suitable

More information

General Specifications

General Specifications General Specifications EJA130E Differential Pressure Transmitter [Style: S2] The high performance differential transmitter EJA130E features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications EJA310E Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJA310E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJ510 and EJ530 bsolute and Gauge Pressure Transmitters [Style: S2] The absolute and gauge pressure transmitter model EJ510 and EJ530 can be used to measure liquid, gas, or steam

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications GS 01C25F01-01E EJX510A and EJX530A Absolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single

More information

General Specifications

General Specifications General Specifications EJA440E Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJA440E features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications EJX120A Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJX120A features single crystal silicon resonant sensor and is suitable

More information

General Specifications

General Specifications General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus

More information

General Specifications

General Specifications General Specifications odel EJA110A Differential Pressure Transmitter GS 01C21B01-00E The high performance differential transmitter model EJA110A can be used to measure liquid, gas, or steam flow as well

More information

General Specifications

General Specifications General Specifications EJX110A Differential Pressure Transmitter [Style: S3] The high performance differential transmitter EJX110A features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJX440A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX440A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications EJX115A Low Flow Transmitter [Style: S1] The low flow transmitter EJX115A is a differential transmitter assembled with an integral orifice and excellent for very low flow measurement.

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

General Specifications

General Specifications General Specifications YTA0, YTA0 Temperature Transmitter [Style: S] The YTA0 and YTA0 are the highly accurate temperature transmitters that accept Thermocouple, RTD, ohms or DC milivolts inputs and converts

More information

General Specifications

General Specifications General Specifications EJA530E S-Series Cherry Burrell I Line Sanitary Pressure Transmitter GS 530SCBS-01E The EJA530E S-Series sanitary pressure transmitters combine Yokogawa s EJA-E series in-line pressure

More information

General Specifications

General Specifications General Specifications EJX130A Differential Pressure Transmitter [Style: S2] The high performance differential transmitter EJX130A features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJX110A Differential Pressure Transmitter GS 01C25B01-01E The high performance differential transmitter EJX110A features single crystal silicon resonant sensor and is suitable to

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter GS 01C25E01-01E [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter [Style: S2] The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications EJX510B and EJX530B Absolute and Gauge Pressure Transmitters The high performance absolute and gauge pressure transmitters EJX510B and EJX530B feature single crystal silicon resonant

More information

General Specifications

General Specifications General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to

More information

General Specifications

General Specifications General Specifications Model EJ430 Gauge Pressure Transmitter GS 01C21E01-00E The high performance gauge transmitter model EJ430 can be used to measure liquid, gas, or steam. It outputs a 4 to 20 m DC

More information

General Specifications

General Specifications General Specifications EJX110A Differential Pressure Transmitter [Style: S3] The high performance differential transmitter EJX110A features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications Model EJ430 Gauge Pressure Transmitter GS 01C21E01-00E The high performance gauge transmitter model EJ430 can be used to measure liquid, gas, or steam. It outputs a 4 to 20 m DC

More information

Differential Pressure Transmitters

Differential Pressure Transmitters AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable

More information

General Specifications

General Specifications General Specifications odel EJ310 bsolute Pressure Transmitter GS 01C21D01-00E The high performance gauge transmitter model EJ310 can be used to measure liquid, gas, or steam. It outputs a 4 to 20 m DC

More information

General Specifications

General Specifications General Specifications odel EJ120 Differential Pressure Transmitter The high performance draft range differential transmitter model EJ120 outputs a 4 to 20 m DC signal corresponding to the measured differential.

More information

General Specifications

General Specifications General Specifications GS 01C21F01-00E odel EJ510 and EJ530 bsolute and Gauge Pressure Transmitter [Style: S2] The absolute and gauge pressure transmitter model EJ510 and EJ530 can be used to measure liquid,

More information

DRS390 High stability, flange mounting

DRS390 High stability, flange mounting DRS 390 1 Monocrystalline silicon smart differential pressure transmitter DRS390 High stability, flange mounting Detailed Information Application the flow of gas, vapor and liquid measurement with device

More information

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS DRS 300 1 Monocrystalline silicon smart differential pressure transmitter DRS300 High stability Detailed Information application the flow of gas, vapor and liquid measurement with device (volume or mass

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

General Specifications

General Specifications General Specifications Model YTA110 Temperature Transmitter GS 01C0B01-00E [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs

More information

Absolute Pressure Transmitters

Absolute Pressure Transmitters AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable

More information

General Specifications

General Specifications General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

General Specifications

General Specifications General Specifications odel EJ130 Differential Pressure Transmitter GS 01C21B04-00E The high performance differential transmitter model EJ130 can be used to measure liquid, gas, or steam flow as well as

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable of

More information

General Specifications

General Specifications General Specifications EJX510 and EJX530 bsolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510 and EJX530 feature single crystal silicon

More information

AT9000 Advanced Transmitter Differential Pressure Transmitters

AT9000 Advanced Transmitter Differential Pressure Transmitters AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable

More information

General Specifications

General Specifications General Specifications EJX510 and EJX530 bsolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510 and EJX530 feature single crystal silicon

More information

General Specifications

General Specifications General Specifications EJX610 and EJX630 bsolute and Gauge Pressure Transmitter The high performance gauge pressure transmitter EJX630 and absolute pressure transmitter EJX610 feature single crystal silicon

More information

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The

More information

General Specifications

General Specifications General Specifications EJX510 and EJX530 bsolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510 and EJX530 feature single crystal silicon

More information

General Specifications

General Specifications General Specifications EJX610 and EJX630 bsolute and Gauge Pressure Transmitter The high performance gauge pressure transmitter EJX630 and absolute pressure transmitter EJX610 feature single crystal silicon

More information

General Specifications

General Specifications General Specifications GS 01F06F01-01EN Model DY Vortex Flowmeter Model DYA Vortex Flow Converter FOUNDATION Fieldbus Communication Type General FOUNDATION Fieldbus is the digital communication line for

More information

General Specifications

General Specifications General Specifications EJX910A Multivariable Transmitter [Style: S2] The high performance EJX910A multivariable transmitter features multi-sensing technology with a single-crystal silicon resonant sensor

More information

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable

More information

DPharp Differential Pressure and Pressure Transmitters

DPharp Differential Pressure and Pressure Transmitters User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change

More information

General Specifications

General Specifications General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO. : C3200-E05A Smart Pressure Transmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of smart transmitter brand series

More information

Field IT 2600T Series Pressure Transmitters

Field IT 2600T Series Pressure Transmitters Data Sheet Field IT 2600T Series Pressure Transmitters Model 364GS Gauge Model 364AS Absolute standard overload Best in class total performance long term stability of 0.25% for 10 years base accuracy of

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability.

More information

User s Manual Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2]

User s Manual Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2] User s Manual Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2] 18th Edition i Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure

More information

Absolute Pressure Transmitters

Absolute Pressure Transmitters No. SS2-GTX00A-0100 AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent

More information

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A Doc. No. : C3100-E05A Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com Smart Pressure Transmitter APT3100 Standard Description

More information

PTG series Smart Pressure Transmitter

PTG series Smart Pressure Transmitter No. SS2-PTG300-0100 PTG series Smart Pressure Transmitter Model PTG71 / PTG72 OVERVIEW The Smart Pressure Transmitter model PTG is a high- performance, highly reliable gauge pressure transmitter. Based

More information

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) DATA SHEET FKH...5 The FCX AIII absolute pressure transmitter (Direct mount type) accurately measures absolute pressure and transmits proportional 4 to

More information

A New Generation of Pressure Transmitters

A New Generation of Pressure Transmitters Fuji Electric Instrumentation & Control A New Generation of Transmitters ECNO : 610d A New addition to the FCX Family at the edge of Technology As a leader in the field of pressure measurement, Fuji Electric

More information

Field IT 2600T Series Pressure Transmitters

Field IT 2600T Series Pressure Transmitters Data Sheet Field IT 2600T Series Pressure Transmitters Model 265GS Gauge Model 265AS Absolute standard overload Base accuracy : ±0.04% Span limits 0.2 to 60000kPa; 0.8inH2O to 8700psi 0.3 to 3000kPa abs;

More information

Compact Orifice Flow Meter

Compact Orifice Flow Meter Data Sheet DS/OM Issue 2 Compact Orifice Flow Meter OriMaster Integrated DP Flow measurement system combines primary element with DP Transmitter in a single flowmeter assembly One-piece flowmeter, pressure

More information

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor 2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter Features Include Base accuracy : ±0.075% Span limits 0.134 to

More information

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability.

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e A New Generation Of Pressure Transmitters -AII V5 ECNO : 610e A New Transmitter at the edge of Technology As a leader in the field of measurement, Fuji Electric has an installed base of more than 1 000

More information