1 AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable of measuring gas, liquid, vapor, and liquid levels, it transmits 4 to 20 ma DC analog and digital signals according to the measured pressure. It can also execute two-way communications between the communicator, thus facilitating selfdiagnosis, range resetting, and automatic zero adjustment. FEATURES High performance and stability Unique characterization and composite semiconductor sensors realize high accuracy up to 0.04% F.S. Our proven sensor technology enables Longterm stability up to 0.1% of URL per 10-year. Wide measuring range (range ability) A wide measuring range is available from a single model. This feature is highly effective in taking measurement over a wide range and reducing the need for inventory. Model GTX60G: 17.5 to 3500 kpa (range ability: 200 to 1) A diverse lineup A wide range of models is available to meet user requirements for low, standard, and high pressures. A wide variety of corrosion-resistant materials for wetted parts is also available. Remote communication Two-way communication using digital output facilitates self-diagnosis, range resetting, automatic zero adjustment, and other operations. HART protocol communication is available. (Option) China RoHS This device is used in the Oil & Gas, Petrochemical, Chemical, Pulp & Paper, Food & Beverage, Machinery, Steel/Metal & Mining, and Automobile industries and therefore does not fall under the China RoHS Legislation. If this device is used in semiconductor manufacturing equipment, labeling on the device and documents for the China RoHS may be required. If such documents are required, consult an Azbil Corp. representative. HART is a registered trademark of the HART Communication Foundation. 17th edition

2 FUNCTIONAL SPECIFICATIONS FM Explosionproof and Dust Approvals (Code F1) Explosionproof for Class I, Division 1, Groups A, B, C and D; Class I, Zone 1, AEx d IIC Dust-Ignitionproof for Class II, III, Division 1, Groups E, F and G T5-40 C < Tamb < +85 C Hazardous locations Indoor / Outdoor Type 4X, IP67 Factory sealed, conduit seal not required for Division applications Caution - Use supply wires suitable for 5 C above surrounding ambient FM Intrinsically safe Approval (Code F2) IS/I,II,III/1/ABCDEFG/T4; -40 C < Tamb < +60 C; , , ; Entity; TYPE 4X; IP67 I/0/ AEx ia/iic/t4; -40 C < Tamb < +60 C; , , ; Entity; TYPE 4X;IP67 Entity Parameters: Vmax(Ui)=30 Volts, Imax(Ii)=100mA, Pi=1W, Ci=10nF, Li=0.5mH FM Nonincendive Approval (Code F5) NI/I/2/ABCD/T4; -40 C < Tamb < +60 C; ; NIFW; TYPE 4X; IP67 NI/I/2/IIC/T4; -40 C < Tamb < +60 C; ; NIFW; TYPE 4X; IP67 S/II,III/1/EFG/T4; -40 C < Tamb < +60 C; ;NIFW; TYPE 4X; P67 Nonincendive Field Wiring Parameters: Vmax(Ui)=30 Volts, Ci=10nF, Li=0.5mH Combination of F1, F2 and F5 (Code F6) ATEX Flameproof and Dust Certifications (Code A1) 0344 KEMA 08ATEX0004 II 1/2 G Ex d IIC T6 Tprocess=85 C -30 C < Tamb < +75 C IP66/67 II 1/2 G Ex d IIC T5 Tprocess=100 C -30 C < Tamb < +80 C IP66/67 II 1/2 G Ex d IIC T4 Tprocess=110 C -30 C < Tamb < +80 C IP66/67 II 2 D Ex td A21 IP66/67 T85 Tprocess=85 C -30 C < Tamb < +75 C II 2 D Ex td A21 IP66/67 T100 Tprocess=100 C -30 C < Tamb < +75 C II 2 D Ex td A21 IP66/67 T110 Tprocess=110 C -30 C < Tamb < +75 C Caution - Use supply wires suitable for 5 C above surrounding ambient ATEX Intrinsic safety and Dust Certifications (Code A2) 0344 KEMA 07ATEX0200 X II 1 G Ex ia IIC T4 TPROCESS = 105 C Azbil Corporation -30 C < Tamb < +60 C IP66 / 67 ELECTRICAL PARAMETERS: Ui = 30 V, Ii = 93 ma, Pi = 1 W, Ci = 5 nf, Li = 0.5 mh II 1 D Ex iad 20 IP66 / 67 T105 TPROCESS = 105 C -30 C < Tamb < +60 C ATEX Type n and Dust Certifications (Code A5) 0344 KEMA 07ATEX0200 X II 3 G Ex nl IIC T4 TPROCESS = 105 C -30 C < Tamb < +60 C IP66 / 67 ELECTRICAL PARAMETERS: Ui = 30 V, Ci = 5 nf, Li = 0.5 mh II 2 D Ex td A21 IP66 / 67 T85 TPROCESS = 85 C -30 C < Tamb < +75 C II 2 D Ex td A21 IP66 / 67 T100 TPROCESS = 100 C -30 C < Tamb < +80 C II 2 D Ex td A21 IP66 / 67 T110 TPROCESS = 110 C -30 C < Tamb < +80 C NEPSI Flameproof and Dust Certifications (Code N1) Ex d IIC T6 DIP A21 TA 85 C Tprocess=80 C -40 C < Tamb < +75 C Ex d IIC T5 DIP A21 TA 100 C Tprocess=95 C -40 C < Tamb < +80 C Ex d IIC T4 DIP A21 TA 115 C Tprocess=110 C -40 C < Tamb < +80 C ENCLOSURE TYPE IP66/67 NEPSI Intrinsic Safety Certification (Code N2) Ex ia IIC T4 Tprocess=105 C -40 C < Tamb < +60 C Enclosure IP66 / 67 Electrical Parameters: Ui=30V, Ii=100mA, Pi=1W, Ci=13nF, Li=0.5mH NEPSI Type n Certification (Code N5) Ex nl IIC T4 Tprocess=110 C -40 C < Tamb < +60 C Enclosure IP66 / 67 Electrical Parameters: Ui=30V, Ii=100mA, Pi=1W, Ci=13nF, Li=0.5mH IECEx Flameproof and Dust Certifications (Code E1) Certificate No. IECEx KEM Ga/Gb Ex d IIC T6 Tprocess=85 C -30 C < Tamb < +75 C IP66/67 Ga/Gb Ex d IIC T5 Tprocess=100 C -30 C < Tamb < +80 C IP66/67 Ga/Gb Ex d IIC T4 Tprocess=110 C -30 C < Tamb < +80 C IP66/67 Ex td A21 IP66/67 T85 Tprocess=85 C -30 C < Tamb < +75 C Ex td A21 IP66/67 T100 Tprocess=100 C -30 C < Tamb < +75 C Ex td A21 IP66/67 T110 Tprocess=110 C -30 C < Tamb < +75 C Caution - Use supply wires suitable for 5 C above surrounding ambient - 2 -

3 Azbil Corporation IECEx Intrinsic safety and Dust Certifications (Code E2) IECEx KEM X Zone 0 Ex ia IIC T4 TPROCESS = 105 C -30 C < Tamb < +60 C IP66 / 67 ELECTRICAL PARAMETERS: Ui = 30 V, Ii = 93 ma, Pi = 1 W, Ci = 5 nf, Li = 0.5 mh Ex iad 20 IP66 / 67 T105 TPROCESS = 105 C -30 C < Tamb < +60 C IECEx Type n and Dust Certifications (Code E5) IECEx KEM X Ex nl IIC T4 TPROCESS = 105 C -30 C < Tamb < +60 C IP66 / 67 ELECTRICAL PARAMETERS: Ui = 30 V, Ci = 5 nf, Li = 0.5 mh Ex td A21 IP66 / 67 T85 TPROCESS = 85 C -30 C < Tamb < +75 C Ex td A21 IP66 / 67 T100 TPROCESS = 100 C -30 C < Tamb < +80 C Ex td A21 IP66 / 67 T110 TPROCESS = 110 C -30 C < Tamb < +80 C KOSHA Flameproof (Code K1) Ex d II C T6 Tprocess = 85 C -30 C < Tamb < +75 C Ex d II C T5 Tprocess = 100 C -30 C < Tamb < +80 C Ex d II C T4 Tprocess = 110 C -30 C < Tamb < +80 C EMC Conformity 89/336/EEC, 92/31/EEC, 93/68/EEC Electromagnetic Compatibility (EMC) Directive PED Conformity (97/23EC) The maximum pressures applicable under the Sound Engineering Practice (SEP) section of the Pressure Equipment Directive depend on the type of fluid measured, as shown in the table below. Measured fluid Gas Group * Pressure Applicable models bar (20 MPa) All models except GTX32D, 42D, 72D, 82G 1,000 bar 2 All models (100 MPa) 500 bar 1 All models (50 MPa) Liquid 1,000 bar 2 All models (100 MPa) Note) Group 1 comprises fluids defines as: explosive, extremely flammable, highly flammable, flammable, very toxic, toxic and oxidizing. Group 2 comprises all other fluids not refer to group 1 Any AT9000 model having a maximum working pressure that is higher than the pressure corresponding to its group does not conform to SEP. Models GTX32D, 42D, 72D and 82G conform to PED according to Module A. No. SS2-GTX00G-0100 Measuring span / Setting range / Working pressure range Mo del GTX 60G GTX 71G GTX 82G Measuring Span 17.5 to 3500 kpa -100 to 3500 kpa 5250 kpa {0.175 to 35 kgf/cm 2 } {-1 to 35 kgf/cm 2 } (*1) {52.5 kgf/cm 2 } 0.7 to 14 MPa -0.1 to 14 MPa 21 MPa {7 to 140 kgf/cm 2 } {-1 to 140 kgf/cm 2 } (*2) {210 kgf/cm 2 } 0.7 to 42 MPa -0.1 to 42 MPa 63 MPa {7 to 420 kgf/cm 2 } {-1 to 420 kgf/cm 2 } (*3) {630 kgf/cm 2 } Note) 1) With PVC parts, the maximum working pressure is 1.5 MPa {15 kgf/cm 2 }. 2) With 304 SST bolts and nuts, the maximum working pressure is 10MPa {100 kgf/cm 2 }. 3) With 304 SST bolts and nuts, the maximum working pressure is 20 MPa {200 kgf/cm 2 }. Working Pressure P (kpa abs/{mmhg}) Working pressure P kpa {mmhg} {1000} {15} 1.3 Figure {1000} {760} 53 {400} Figure 2 Operative limit Measuring range Normal operating range Unusable range Overload Resistance value Operative limit Temperature of wetted parts ( C) Working pressure and temperature of wetted parts section (for general purpose models) Unusable range Normal operating range Temperature of wetted parts ( C) Working pressure and temperature of wetted parts section (for oxygen and chlorine service) - 3 -

4 Supply voltage and load resistance 17.9 to 42V DC. Reverse polarity protection is standard. A load resistance of 250 Ω or more is necessary between loops. See Figure 3. Load resistance (Ω) Load resistance (W) Supply voltage = Operating Range Supply voltage (V DC) Figure 3 Supply voltage vs. load resistance characteristics Note) For communication with HART communicator or Comm- Pad, a load resistance of 250 Ω or more is necessary. Output Analog output (4 to 20 ma DC) with DE protocol Analog output (4 to 20 ma DC) with HART protocol Digital output (DE protocol) Output signal 3.6 to 21.6 ma 3.8 to 20.5 ma (NAMUR NE43 compliant) Failure Alarm Upper: 21.6 ma or more Lower: 3.6 ma or less Ambient temperature limit Normal operating range -40 to 85 C for general purpose models -10 to 75 C for oxygen and chlorine models -25 to 80 C for models with digital indicators Operative limits -50 to 93 C for general purpose models -40 to 80 C for oxygen and chlorine models -30 to 85 C for models with digital indicators Transportation and storage conditions -50 to 85 C Temperature ranges of wetted parts Normal operating range -40 to 110 C for general purpose models -20 to 75 C for oxygen and chlorine models Operative limits -50 to 115 C for general purpose models -40 to 80 C for oxygen and chlorine models Ambient humidity limits 5 to 100% RH Stability against supply voltage change ± 0.005% FS/V Azbil Corporation Response time Below 100 msec. (when damping time is set to 0 sec.) Damping time Selectable from 0 to 32 sec. in ten stages Zero Stability ± 0.1% of URL per 10 year (model GTX60G) Lightning protection Applicable Standards; IEC Peak value of current surge(80/20μ sec.): 6000A Indicator The digital LCD indicator (optional) indicates engineering units and can be set freely between and (5 digits). For meter calibration, specify the following items when placing your order Meter calibration range Meter calibration unit Linear / Square-root for meter indication. Various kinds of data can be set using the communicator. Bolts and nuts materials (for fastening meter body cover) Carbon steel (SNB7), 304 SST, 316 SST, 630 SST Paint Standard Corrosion-resistant paint (Baked acrylic paint) Corrosion-proof finish Corrosion-proof paint (Baked urethane paint), fungusproof finish OPTIONAL SPECIFICATIONS Oil free finish The transmitter is shipped with oil-free wetted parts. External zero/span adjustment function The transmitter can be easily zero/span adjusted in the field. Elbow This is an adaptor for changing the electrical conduit connection port from the horizontal to the vertical direction, if required by wiring conditions in the field. One or two elbows may be used as needed. Conformance to Non SI units We deliver transmitters set to any Non SI units as specified. Safety Transmitter Select this option to be used as a component of Safety Instrumented System (SIS). AT9000 is complied with IEC61508, certified according to Safety Integrity Level2 (SIL-2) Alarm Output (contact output) Contact output is prepared as alarm output when alarm (Output Alarm/Sensor Temp. Alarm) condition is detected. It can be set to Normally Open. (When alarm is detected, Contact ON). Custom calibration Calibrate for the specified pressure range at the factory

5 Azbil Corporation PHYSICAL SPECIFICATIONS Materials Fill fluid Silicone oil for general purpose models Fluorine oil for oxygen and chlorine models Center body 316 SST Transmitter case Aluminum alloy, CF8M (Equivalent to 316 SST) Meter body cover SCS14A (Equivalent to 316 SST) or 316 SST, PVC For Wetted parts Adapter flange (option) SCS14A (Equivalent to 316 SST), PVC Center body 316 SST (Diaphragm 316L SST) ASTM B575 (Equivalent to Hastelloy C-276), Tantalum, 316L SST Vents and plugs 316 SST, PVC Weight Approx. 3.6 kg (model GTX60G) INSTALLATION Electrical connection 1/2NPT internal thread, M20 internal thread. Grounding Resistance 100 Ω max. Mounting Can be installed on a 2-inch horizontal or vertical pipe (can be directly mounted on a process pipe) Process connection Rc1/2, 1/2NPT internal thread and Rc1/4, 1/4NPT internal thread. TRANSMITTER HANDLING NOTES To get the most from the performance this transmitter can offer, please use it properly noting the points mentioned below. Before using it, please read the Instruction Manual. Transmitter installation notes WARNING When installing the transmitter, ensure that gaskets do not protrude from connecting points into the process (such as adapter flange connection points and connecting pipes and flanges). Failure to do so may cause a leak of process fluid, resulting in harm from burns, etc. In addition, if the process fluid contains toxic substances, take safety measures such as wearing goggles and a mask to prevent contact with the skin and eyes and to prevent inhalation. Wiring notes No. SS2-GTX00G-0100 WARNING Use the transmitter within the operating ranges stated in the specifications (for explosionproofing, pressure rating, temperature, humidity, voltage, vibration, shock, mounting direction, atmosphere, etc.). Using the transmitter outside the operating conditions may cause device failure or fire, resulting in a harmful physical risk of burning or the like. When performing wiring work in explosion-proof areas, follow the work method specified in the explosion-proof guidelines. CAUTION After installation, do not use the transmitter as a foothold or put your weight on it. Doing so may cause damage. Be careful not to hit the glass indicator with tools etc. This could break the glass and cause injury. The transmitter is heavy. Wear safety shoes and take care when installing it. Impact to transmitter can damage sensor module. WARNING To avoid shocks, do not perform electrical wiring work with wet hands or with live wires. CAUTION Do wiring work properly in conformance with the specifications. Wiring mistakes may result in malfunction or irreparable damage to the instrument. Use a power supply that conforms to the specifications. Use of an improper power supply may result in malfunction or irreparable damage to the instrument. Use a power supply with overcurrent protection for this instrument. Handling precautions for HART specification devices If you need to operate with a secondary host (HART communicator, etc.), set the communication interval of the primary host (DCS, device management system) to 8 seconds or more, or suspend communication from the primary host. If the primary host repeats HART communication within 8 seconds, the request from the secondary host may not be received (communication may not be possible). If electrical noise in the environment prevents HARTcommunications with the host, take countermeasures such as separating the signal cables from the source of the noise, improving the grounding, changing to shielded signal cables, etc. Even if noise interferes with HART communications, the 4-20 ma analog signal will be unaffected and can be used for control. If this product is being operated in multidrop mode, there is a limit to the number of devices that can be used. If you are using multidrop mode, please consult with us

6 Azbil Corporation PERFORMANCE SPECIFICATIONS Reference accuracy Shown for each item are the percentage ratio for χ (kpa), which is the greatest value of either the upper range value (URV) *1, the lower range value (LRV) *2 or the span. Model GTX60G (for regular type) (Material of wetted parts: Diaphragm; 316L SST, Others; 316 SST) Reference accuracy ± 0.04% (*3)(*4)(*5) (For χ > 350 kpa {3.5 kgf/cm 2 }) ± χ % (For χ < 350 kpa {3.5 kgf/cm 2 }) Ambient Temperature effect (Shift from the set range) Change of 30 C (*3) Combined shift: (including zero and span shifts) Model GTX60G (for oxygen / chlorine service) ± 0.15% (For χ > 350 kpa {3.5 kgf/cm 2 }) ± % (For χ < 350 kpa {3.5 kgf/cm 2 }) χ (Material of wetted parts: Diaphragm; 316L SST, Others; 316 SST) Reference accuracy ± 0.075% (For χ > 1750 kpa {17.5 kgf/cm 2 }) (*3)(*4) ± 0.1% (1750 kpa{17.5 kgf/cm 2 } > χ > 140 kpa {1.4 kgf/cm 2 }) Temperature characteristics (Shift from the set range) Change of 30 C (*3) (Range from -5 to 55ºC) Combined shift: (including zero and span shifts) ± % χ (For χ < 140 kpa {1.4 kgf/cm 2 }) ± 0.44% (For χ > 350 kpa {3.5 kgf/cm 2 }) ± % χ (For χ < 350 kpa {3.5 kgf/cm 2 }) Model GTX60G (for regular type / oxygen / chlorine service) (Material of wetted parts: Diaphragm; ASTM B575 (Equivalent to Hastelloy C-276), Tantalum, 316L SST Others; ASTM B575 (Equivalent to Hastelloy C-276), Tantalum, 316L SST) Reference accuracy ± 0.2% (For χ > 350kPa {3.5 kgf/cm 2 }) (*3)(*4) Ambient Temperature effect (Shift from the set range) Change of 30 C (*3)(Range from -5 to 55 C) Combined shift: (including zero and span shifts) ± χ % (For χ < 350 kpa {3.5 kgf/cm 2 }) ± 0.85% (For χ > 350 kpa {3.5 kgf/cm 2 }) ± % (For χ < 350 kpa {3.5 kgf/cm 2 }) χ Note) *1) URV denotes the process value for 100% (20 ma DC) output. *2) LRV denotes the process value for 0% (4 ma DC) output. *3) Within a range of URV > 0 and LRV > 0. *4) Reference accuracy at calibrated condition. *5) In case code D "Digital output (DE communication)" is selected, reference accuracy becomes the same as one of "for oxygen /chlorine service"

7 Azbil Corporation No. SS2-GTX00G-0100 Model GTX71G (for regular type / oxygen / chlorine service) (Material of wetted parts: Diaphragm; 316L SST, Others; 316 SST) Reference accuracy (*3)(*4) ± 0.15% (For χ > 2.1 MPa {21 kgf/cm 2 }) Ambient Temperature effect (Shift from the set range) Change of 30 C (*3) Combined shift: (including zero and span shifts) ± % χ (For χ < 2.1 MPa {21 kgf/cm 2 }) ± 0.41% (For χ > 3.5 MPa{35 kgf/cm 2 }) ± % χ (For χ < 3.5 MPa {35 kgf/cm 2 }) Model GTX71G (for regular type / oxygen / chlorine service) (Material of wetted parts: Diaphragm; ASTM B575 (Equivalent to Hastelloy C-276), Tantalum, 316L SST Others; ASTM B575 (Equivalent to Hastelloy C-276), Tantalum, 316L SST) Reference accuracy ± 0.2% (For χ > 2.1 MPa {21 kgf/cm 2 }) (*3)(*4) Ambient Temperature effect (Shift from the set range) Change of 30 C (*3) (Range from -5 to 55 C) Combined shift: (including zero and span shifts) Model GTX82G (for regular type / oxygen / chlorine service) ± % (For χ < 2.1 MPa {21 kgf/cm 2 }) χ ± 0.85% (For χ > 3.5 MPa {35 kgf/cm 2 }) ± % (For χ < 3.5 MPa {35 kgf/cm 2 }) χ (Material of wetted parts: Diaphragm; 316L SST, Others; 316 SST) Reference accuracy (*3) (*4) ± 0.15% (For χ > 7 MPa {70 kgf/cm 2 }) Ambient Temperature effect (Shift from the set range) Change of 30 C (*3) Combined shift: (including zero and span shifts) ± % χ (For χ < 7 MPa {70 kgf/cm 2 }) ± 0.41% (For χ > 7 MPa {70 kgf/cm 2 }) ± % χ (For χ < 7 MPa {70 kgf/cm 2 }) Model GTX82G (for regular type / oxygen / chlorine service) (Material of wetted parts: Diaphragm; ASTM B575 (Equivalent to Hastelloy C-276)) Reference accuracy ± 0.15% (For χ > 7 MPa {70 kgf/cm 2 }) (*3)(*4) ± % (For χ < 7 MPa {70 kgf/cm 2 }) χ Ambient Temperature effect (Shift from the set range) Change of 30 C (*3) (Range from -5 to 55 C) Combined shift: (including zero and span shifts) ± 0.85% (For χ > 7 MPa{70 kgf/cm 2 }) ± % + (For χ < 7 MPa {70 kgf/cm 2 }) χ *3) Within a range of URV > 0 and LRV > 0. *4) Reference accuracy at calibrated condition

8 Azbil Corporation MODEL SELECTION Model GTX60G (Standard gauge pressure) Model No.:GTX G - Selection I (I II III IV V VI VII) - Selection II (I II III IV V VI) - Option Basic Model No. Measuring span 17.5 to 3500kPa (0.175 to 35kgf/cm 2 ) GTX60G Selection I I Output 4 to 20mA (SFN Communication) A 4 to 20mA (HART Communication) B Digital output (DE communication) *10 D II Fill fluid Regular type (Silicone oil) A For oxygen service (Fluorine oil) H For chlorine service (Fluorine oil) *6 J III Material (Meterbody Meterbody cover Vent / Drain plugs cover, Vent/ SCS14A 316 SST A Drain plugs) PVC *4 *7 *8 PVC *4 *7 *8 C IV Material (center 316 SST (Diaphragm: 316L SST) A body) ASTM B575 (Equivalent to Hastelloy C-276) B Tantalum *5 *11 C 316L SST *5 *11 D V Process connections Rc 1/2, with adapter flange A Rc 1/4, with adapter flange B Rc 1/4, without adapter flange C 1/2 NPT internal thread, with adapter flange D 1/4 NPT internal thread, with adapter flange E 1/4 NPT internal thread, without adapter flange F VI Process installation Vertical piping, top connection A Vertical piping, bottom connection B Horizontal piping, front connection C VII Bolt/nut 304 SST B 316 SST *12 D Selection II - I Electrical connection 1/2 NPT, Watertight A M20, Watertight *9 B II Explosion proof None XX FM Explosion proof F1 FM Intrinsically safe F2 FM Nonincendive F5 Combined of FM Explosion proof, Intrinsically safe and Nonincendive F6 ATEX Explosion proof A1 ATEX Intrinsically safe A2 ATEX Type n A5 IECEx Explosion proof, E1 IECEx Intrinsically safe E2 IECEx Type n E5 NEPSI Explosionproof *14 N1 NEPSI Intrinsically safe *14 N2 NEPSI Type n *14 N5 KOSHA Explosion proof *14 K1 III Indicator None X With indicator A IV Paint *13 Standard X None (316 stainless steel housing) E Corrosion-proof (Urethane) H V Failure alarm Upper limit of output at abnormal condition A Lower limit of output at abnormal condition B VI Mounting bracket None X CF8 (L form) *2 1 CF8M (L form) *12 2 Carbon steel (Flat form) * SST (Flat form) *3 6 Note) *2 Applicable for wetted parts of material (center body);316 SST and ASTM B575 *3 Applicable for wetted parts of material (center body); Tantalum and 316L SST. *4 304 SST bolts and nuts material (-B) must be selected when PVC meterbody cover is selected.the max. working pressure is 1.5MPa. *5 In case code C, or D is selected, code A, or B of Process installation should be selected. (Continued) - 8 -

9 Azbil Corporation No. SS2-GTX00G-0100 (Continued from previous page) *6 In case code J is selected, code C Tantalum of Material (meterbody) should be selected. *7 In case PVC is selected, code A, or D of Process connections should be selected. *8 In case PVC is selected, code A, or B of Process installation should be selected. *9Not applicable for the combination with code F1, F6 of Explosion proof. *10 Not applicable for the combination with code A2 "With external Zero/Span adjustment", Q1 "Safety Transmitter" and Q2 "NAMUR NE43 Compliant Output Signal Limits" of Option. *11 Not applicable for the combination with code D of Bolt/nut. *12 In case this code is selected, code P8 of Option code should be selected. *13 In case code X, H, or D is selected, the material of transmitter case is aluminum alloy. *14 Not applicable for the combination with code E of Paint. Model No.:GTX G-Selection I ( I II III IV V VI VII) - Selection II (I II III IV V VI ) - Option Option - No options XX With external Zero/Span adjustment*11*13 A2 One elbow (left) *6 *7 *10 G1 One elbow (right) *6 *7 *10 G2 2 elbows *6 *8 *10 G3 Long vent/drain plugs G4 Side vent/drain top *6 G6 Side vent/drain bottom *6 G7 Oil and water free finish K1 Oil free finish *4 K3 Au Plating Diaphragm *12 L1 316 SST (Parts in contact with atmosphere) *15 *16 *17 P8 Safety Transmitter *5 *13 Q1 NAMUR NE43 Compliant Output Signal Limits:3.8 to 20.5mA (Output 21.6mA/selected upper limit, 3.6mA/selected lower Q2 limit) *13 Alarm Output (contact output) *14 Q7 Custom calibration R1 Test report T1 Mill certificate T2 Traceability certificate T4 NACE certificate *9 T5 Non SI Unit W1 Note) *4 No need to select when Fill Fluid code H, or J is selected. *5 Not applicable for the combination with code A2,or Q7 of Option. *6 Not applicable for the combination with code A, or B of Process installation. *7 Not applicable for the combination with code F1 FM Explosion proof of Explosion proof. *8 Not applicable for any Explosion proof. Please select code F1 None of Explosion proof. *9 Applicable for ASTM B575, code B of Material (center body). *10 Not applicable for the combination with code B M20, Watertight electrical connection. *11 Not applicable for the combination with code X None of Indicator. Please select With indicator. *12 Not applicable for the combination with code C Tantalum of Material (center body). *13 Not applicable for the combination with code D "Digital output (DE communication)" of output. *14 Not applicable for the combination with code F2, F5, F6, N2, N5, E2, E5, A2 and A5 of Explosion proof. *15 In case code P8 is selected, code D of Bolt/nut should be selected. *16 In case code P8 is selected, code E of Paint should be selected. *17 In case code P8 is selected, code X or 2 of Mounting bracket shoult be selected

10 Azbil Corporation Model GTX71G (High gauge pressure) Model No.:GTX G - Selection I (I II III IV V VI VII) - Selection II (I II III IV V VI) - Option Basic Model No. Measuring span 0.7 to 14MPa (7 to 140kgf/cm 2 ) GTX71G Selection I I Output 4 to 20mA (SFN Communication) A 4 to 20mA (HART Communication) B Digital output (DE communication)*9 D II Fill fluid Regular type (Silicone oil) A For oxygen service (Fluorine oil) H For chlorine service (Fluorine oil) *7 J III Material (Meterbody Meterbody cover Vent / Drain plugs cover, Vent/ Drain plugs) SCS14A 316 SST A IV Material (center 316 SST (Diaphragm: 316L SST) A body) ASTM B575 (Equivalent to Hastelloy C-276) B Tantalum *6 *10 C 316L SST *6 *10 D V Process connections Rc 1/2, with adapter flange A Rc 1/4, with adapter flange B Rc 1/4, without adapter flange C 1/2 NPT internal thread, with adapter flange D 1/4 NPT internal thread, with adapter flange E 1/4 NPT internal thread, without adapter flange F VI Process installation Vertical piping, top connection *6 A Vertical piping, bottom connection *6 B Horizontal piping, front connection C VII Bolt/nut Carbon steel A 304 SST *5 B 630 SST C 316 SST *5 *11 D Selection II - I Electrical connection 1/2 NPT, Watertight A M20, Watertight *8 B II Explosion proof None XX FM Explosion proof F1 FM Intrinsically safe F2 FM Nonincendive F5 Combined of FM Explosion proof, Intrinsically safe and Nonincendive F6 ATEX Explosion proof A1 ATEX Intrinsically safe A2 ATEX Type n A5 IECEx Explosion proof, E1 IECEx Intrinsically safe E2 IECEx Type n E5 NEPSI Explosionproof *13 N1 NEPSI Intrinsically safe *13 N2 NEPSI Type n *13 N5 KOSHA Exposion proof *13 K1 III Indicator None X With indicator A IV Paint *12 Standard X None (316 stainless steel housing) E Corrosion-proof (Urethane) H V Failure alarm Upper limit of output at abnormal condition A Lower limit of output at abnormal condition B VI Mounting bracket None X CF8 (L form) *2 1 CF8M (L form) *11 2 Carbon steel (Flat form) * SST (Flat form) *3 6 Note) *2 Applicable for wetted parts of material (center body);316 SST,ASTM B575. *3 Applicable for wetted parts of material (center body);tantalum,316l SST. (Continued)

11 Azbil Corporation No. SS2-GTX00G-0100 (Continued from previous page) *5 When 304/316 SST bolt/nut is selected, max working pressure rating is 10MPa(100kgf/cm2). *6 In case code C, or D is selected, code A, or B of Process installation should be selected. *7 In case code J is selected, code C "Tantalum" of Material (centerbody) should be selected. *8 Not applicable for the combination with code F1, F6 of Explosion proof. *9 Not applicable for the combination with code A2 "With external Zero/Span adjustment", Q1 "Safety Transmitter" and Q2 "NAMUR NE43 Compliant Output Signal Limits" of Option. *10 Not applicable for the combination with code D of Bolt/nut. *11 In case this code is selected, code P8 of Option code should be selected. *12 In case code X, H, or D is selected, the material of transmitter case is aluminum alloy. *13 Not applicable for the combination with code E of Paint. Model No.:GTX G-Selection I (I II III IV V VI VII ) - Selection II (I II III IV V VI ) - Option Option - No options XX With external Zero/Span adjustment *11*13 A2 One elbow (left) *6 *7 *10 G1 One elbow (right) *6 *7 *10 G2 2 elbows *6 *8 *10 G3 Long vent/drain plugs G4 Side vent/drain top *6 G6 Side vent/drain bottom *6 G7 Oil and water free finish K1 Oil free finish *4 K3 Au Plating Diaphragm *12 L1 316 SST (Parts in contact with atmosphere) *15 *16 *17 P8 Safety Transmitter *5 *13 Q1 NAMUR NE43 Compliant Output Signal Limits:3.8 to 20.5mA (Output 21.6mA/selected upper limit, 3.6mA/selected lower Q2 limit) *13 Alarm Output (contact output) *14 Q7 Custom calibration R1 Test report T1 Mill certificate T2 Traceability certificate T4 NACE certificate *9 T5 Non SI Unit W1 Note) *3 Not applicable for the combination with 304 SST Bolts/Nuts. *4 No need to select when Fill Fluid code H, or J is selected. *5 Not applicable for the combination with code A2,or Q7 of Option. *6 Not applicable for the combination with code A, or B of Process installation. *7 Not applicable for the combination with code F1, F6 of Explosion proof. *8 Not applicable for any Explosion proof. Please select code F1 None of Explosion proof. *9 Applicable for ASTM B575, code B of Material (center body). *10 Not applicable for the combination with code B M20, Watertight electrical connection. *11 Not applicable for the combination with code X None of Indicator. Please select With indicator. *12 Not applicable for the combination with code C Tantalum of Material (center body). *13 Not applicable for the combination with code D "Digital output (DE communication)" of output. *14 Not applicable for the combination with code F2, F5, F6, N2, N5, E2, E5, A2 and A5 of Explosion proof. *15 In case code P8 is selected, code D of Bolt/nut should be selected. *16 In case code P8 is selected, code E of Paint should be selected. *17 In case code P8 is selected, code X or 2 of Mounting bracket shoult be selected

12 Azbil Corporation Model GTX82G (High gauge pressure) Model No.:GTX G - Selection I (I II III IV V VI VII) - Selection II(I II III IV V VI) - Option Basic Model No. Measuring span 0.7 to 42MPa (7 to 420kgf/cm 2 ) GTX82G Selection I I Output 4 to 20mA (SFN Communication) A 4 to 20mA (HART Communication) B Digital output (DE communication) *7 D II Fill fluid Regular type (Silicone oil) A For oxygen service (Fluorine oil) H III Material (Meterbody Meterbody cover Vent / Drain plugs cover, Vent/ Drain plugs) 316 SST 316 SST A IV Material (center 316 SST (Diaphragm: 316L SST) A body) ASTM B575 (Equivalent to Hastelloy C-276) B V Process connections Rc 1/2, with adapter flange, for high pressure model P Rc 1/4, with adapter flange, for high pressure model R Rc 1/4, without adapter flange, for high pressure model S l/2npt internal thread, with adapter flange, for high pressure T model l/4npt internal thread, with adapter flange, for high pressure W model l/4npt internal thread, without adapter flange, for high pressure model Y VI Process installation Vertical piping, top connection A Vertical piping, bottom connection B Horizontal piping, front connection C VII Bolt/nut Carbon steel A 304 SST *5 B 630 SST C 316 SST *5 *8 D Selection II - I Electrical connection 1/2 NPT, Watertight A M20, Watertight *6 B II Explosion proof None XX FM Explosion proof F1 FM Intrinsically safe F2 FM Nonincendive F5 Combined of FM Explosion proof, Intrinsically safe and Nonincendive F6 ATEX Explosion proof A1 ATEX Intrinsically safe A2 ATEX Type n A5 IECEx Explosion proof, E1 IECEx Intrinsically safe E2 IECEx Type n E5 NEPSI Explosionproof *10 N1 NEPSI Intrinsically safe *10 N2 NEPSI Type n *10 N5 KOSHA Explosion proof *10 K1 III Indicator None X With indicator A IV Paint Standard X None (316 stainless steel housing) E Corrosion-proof (Urethane) H V Failure alarm Upper limit of output at abnormal condition A Lower limit of output at abnormal condition B VI Mounting bracket None X CF8 (L form) 1 CF8M (L form) *8 2 Note) *5 When 304/316 SST bolt/nut is selected, max working pressure rating is 20MPa(200kgf/cm2). *6 Not applicable for the combination with code F1, F6 of Explosion proof. *7 Not applicable for the combination with code A2 "With external Zero/Span adjustment", Q1 "Safety Transmitter" and Q2 "NAMUR NE43 Compliant Output Signal Limits" of Option. (Continued)

13 Azbil Corporation No. SS2-GTX00G-0100 (Continued from previous page) *8 In case this code is selected, code P8 of Option code should be selected. *9 In case code X, H, or D is selected, the material of transmitter case is aluminum alloy. *10 Not applicable for the combination with code E of Paint. Model No.:GTX G-Selection I (I II III IV V VI VII ) - Selection II(I II III IV V VI) - Option Option - No options XX With external Zero/Span adjustment*11*13 A2 One elbow (left) *6 *7 *10 G1 One elbow (right) *6 *7 *10 G2 2 elbows *6 *8 *10 G3 Long vent/drain plugs G4 Side vent/drain top *6 G6 Side vent/drain bottom *6 G7 Oil and water free finish K1 Oil free finish *4 K3 Au Plating Diaphragm *12 L1 316 SST (Parts in contact with atmosphere) *15 *16 *17 P8 Safety Transmitter *5 *13 Q1 NAMUR NE43 Compliant Output Signal Limits:3.8 to 20.5mA (Output 21.6mA/selected upper limit, 3.6mA/selected lower Q2 limit) *13 Alarm Output (contact output) *14 Q7 Custom calibration R1 Test report T1 Mill certificate T2 Traceability certificate T4 NACE certificate *9 T5 Non SI Unit W1 Note) *3 Not applicable for the combination with 304 SST Bolts/Nuts. *4 No need to select when Fill Fluid code H, or J is selected. *5 Not applicable for the combination with code A2,or Q7 of Option. *6 Not applicable for the combination with code A, or B of Process installation. *7 Not applicable for the combination with code F1, F6 of Explosion proof. *8 Not applicable for any Explosion proof. Please select code F1 None of Explosion proof. *9 Applicable for ASTM B575, code B of Material (center body). *10 Not applicable for the combination with code B M20, Watertight electrical connection. *11 Not applicable for the combination with code X None of Indicator. Please select With indicator. *12 Not applicable for the combination with Tantalum of diaphragm Material. *13 Not applicable for the combination with code D "Digital output (DE communication)" of output. *14 Not applicable for the combination with code F2, F5, F6, N2, N5, E2, E5, A2 and A5 of Explosion proof. *15 In case code P8 is selected, code D of Bolt/nut should be selected. *16 In case code P8 is selected, code E of Paint should be selected. *17 In case code P8 is selected, code X or 2 of Mounting bracket should be select

14 Azbil Corporation DIMENSIONS Model GTX60G (Material (center body): 316 SST, ASTM B575)

15 Azbil Corporation No. SS2-GTX00G-0100 Model GTX71G (Material (center body): 316 SST, ASTM B575)

16 Azbil Corporation Model GTX82G

17 Azbil Corporation No. SS2-GTX00G

18 Azbil Corporation Model GTX60G/71G (Material (center body): Tantalum, 316L SST) Process connection: Top or bottom side

19 Azbil Corporation No. SS2-GTX00G-0100 Model GTX60G(Material (Meter body cover, Vent/Drain plugs: PVC) Process connection: Top or bottom side

20 Azbil Corporation Please, read Terms and Conditions from following URL before the order and use. Specifications are subject to change without notice Kawana, Fujisawa Kanagawa Japan (11) st edition: May th edition: July 2015 No part of this publication may be reproduced or duplicated without the prior written permission of Azbil Corporation.

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model No. SS2-GTX00G-0600 AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance

More information

PTG series Smart Pressure Transmitter

PTG series Smart Pressure Transmitter No. SS2-PTG300-0100 PTG series Smart Pressure Transmitter Model PTG71 / PTG72 OVERVIEW The Smart Pressure Transmitter model PTG is a high- performance, highly reliable gauge pressure transmitter. Based

More information

ABSOLUTE PRESSURE TRANSMITTER

ABSOLUTE PRESSURE TRANSMITTER ABSOLUTE PRESSURE TRANSMITTER DATA SHEET FKA...5 The FCX -AIII absolute pressure transmitter accurately measures absolute pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes

More information

General Specifications

General Specifications General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO. : C3200-E05A Smart Pressure Transmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of smart transmitter brand series

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications EJX110A Differential Pressure Transmitter GS 01C25B01-01E The high performance differential transmitter EJX110A features single crystal silicon resonant sensor and is suitable to

More information

General Specifications

General Specifications General Specifications EJA130E Differential Pressure Transmitter The high performance differential transmitter EJA130E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant

More information

General Specifications

General Specifications General Specifications EJX510A and EJX530A Absolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal silicon

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

General Specifications

General Specifications General Specifications EJA530E S-Series Cherry Burrell I Line Sanitary Pressure Transmitter GS 530SCBS-01E The EJA530E S-Series sanitary pressure transmitters combine Yokogawa s EJA-E series in-line pressure

More information

General Specifications

General Specifications General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

General Specifications

General Specifications General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant

More information

FUNCTIONAL SPECIFICATIONS

FUNCTIONAL SPECIFICATIONS DATA SHEET The ProcessX differential pressure (flow) transmitter accurately measures differential pressure, liquid leel, gauge pressure or fl ow rate and transmits a proportional 4 to 20mA signal. The

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

Pressure transmitter (Direct mount type) Caractéristique fonctionnelles FKP* { } {1.3} FKP* {0.

Pressure transmitter (Direct mount type) Caractéristique fonctionnelles FKP* { } {1.3} FKP* {0. DT SHEET The ProcessX pressure transmitter accurately measures gauge pressure and transmits proportional 4 to 20m signal. The transmitter utilizes the unique micromachined capacitie silicon sensor with

More information

General Specifications

General Specifications General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement

Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement Doc. No. : C3100-E05A FM APPROVED Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of

More information

AT9000 Advanced Transmitter Electronic Differential Pressure/ Pressure Transmitter with DE and HART Bilingual Communications.

AT9000 Advanced Transmitter Electronic Differential Pressure/ Pressure Transmitter with DE and HART Bilingual Communications. CM2-GTX100-2005 AT9000 Advanced Transmitter Electronic Differential Pressure/ Pressure Transmitter with DE and HART Bilingual Communications User s Manual NOTICE While the information in this manual is

More information

FKH...5. Absolute pressure transmitter DATA SHEET FEATURES SPECIFICATIONS. Functional specifications

FKH...5. Absolute pressure transmitter DATA SHEET FEATURES SPECIFICATIONS. Functional specifications DT SHEET The ProcessX absolute pressure transmitter (direct mount type) accurately measures absolute pressure and transmits proportional 4 to 20m signal. The transmitter utilizes the unique micromachined

More information

Series Smart Pressure Transmitter

Series Smart Pressure Transmitter www.tek-trol.com TEK-BAR 3100 Series Smart Pressure Transmitter www.tek-trol.com 2 Introduction The Tek-Bar series of smart transmitters have excellent stability, high accuracy and include features that

More information

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement For Gauge And Absolute Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate

More information

SATRON VB Pressure Transmitter

SATRON VB Pressure Transmitter SATRON VB pressure transmitter belongs to the series V transmitters. SATRON VB is userfriendly, through the ball valve mounted transmitter which is used for 04 kpa... 03 MPa ranges. The transmitter communicates

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

LGP Design. Can be ordered separately see specification 34-ST-03-55

LGP Design. Can be ordered separately see specification 34-ST-03-55 ST 3000 Smart Transmitter Series 900 Gauge Pressure Models STG944 0 to 500 psi 0 to 35 STG94L 0 to 500 psi 0 to 35 STG974 0 to 3000 psi 0 to 210 STG97L 0 to 3000 psi 0 to 210 STG98L 0 to 6000 psi 0 to

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE

More information

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Installation guide 873 SmartRadar Control Unit & Antenna Unit Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl

More information

OPTIMASS 1000 Technical Datasheet

OPTIMASS 1000 Technical Datasheet OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only

More information

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications

More information

FKP...5. Pressure transmitter (direct mount type) DATA SHEET FEATURES. Functional specifications

FKP...5. Pressure transmitter (direct mount type) DATA SHEET FEATURES. Functional specifications DT SHEET The ProcessX pressure transmitter accurately measures gauge pressure and transmits proportional 4 to 20 m signal. The transmitter utilizes the unique micromachined capacitie silicon sensor with

More information

Specifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span

Specifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span PERFORMANCE SPECIFICATIONS Reference Accuracy (1) Specifications Total Performance is based on combined errors of reference accuracy, ambient temperature effect, and static pressure effect. This product

More information

General Specifications

General Specifications General Specifications EJX910A Multivariable Transmitter [Style: S2] The high performance EJX910A multivariable transmitter features multi-sensing technology with a single-crystal silicon resonant sensor

More information

FKE...F. Level transmitter DATA SHEET FEATURES SPECIFICATIONS

FKE...F. Level transmitter DATA SHEET FEATURES SPECIFICATIONS DT SHEET The ProcessX leel transmitter accurately measures absolute pressure and transmits proportional 4 to 20m signal. The transmitter utilizes the unique micromachined capacitie silicon sensor with

More information

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications

More information

ThermoPLUS Smart Temperature Transmitter

ThermoPLUS Smart Temperature Transmitter No. SS2-TT110-0100 ThermoPLUS Smart Temperature Transmitter Model TT61/71 (Integral Sensor type) OVERVIEW The models TT61/71 Smart Transmitter are temperature transmitters for the model TT90 integral temperature

More information

ITEM. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023

ITEM. Can be ordered separately see specification 34-ST Industrial Automation and Control, N. Black Canyon Highway, Phoenix, AZ 85023 ST 3000 Smart Transmitter Series 100 Absolute Pressure Models STA122 0 to 780 mmhga 0 to 1,040 mbara STA140 0 to 500 psia 0 to 35 bara Function 34-ST-03-61 11/98 Specification and Model Selection Guide

More information

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE

More information

Relative and absolute pressure transmitter type 528

Relative and absolute pressure transmitter type 528 Relative and absolute pressure transmitter type 528 The compact type 528 pressure transmitter is based upon the Huba Control developed and since over 20 years well proven ceramic technology. These transmitters

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e A New Generation Of Pressure Transmitters -AII V5 ECNO : 610e A New Transmitter at the edge of Technology As a leader in the field of measurement, Fuji Electric has an installed base of more than 1 000

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

ST 3000 Smart Transmitter Series 100 Gauge Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /04

ST 3000 Smart Transmitter Series 100 Gauge Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /04 ST 3000 Smart Transmitter Series 100 Gauge Pressure Models STG140/STG14L 0 to 500 psi 0 to 35 bar STG170/STG18L 0 to 3000 psi 0 to 210 bar STG180/STG18L 0 to 6000 psi 0 to 415 bar STG19L 0 to 10000 psi

More information

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters Data Sheet Brooks Industrial Brooks Digital Series Digital MFC's and MFM's Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters General Features:

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

Strong monosilicon gauge pressure transmitter

Strong monosilicon gauge pressure transmitter Product introduction Description Strong monosilicon gauge pressure transmitter SMP858 monosilicon pressure transmitter is a high performance pressure transmitter with international leading technology meticulously

More information

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

General Specifications

General Specifications General Specifications Model EJ430 Gauge Pressure Transmitter GS 01C21E01-00E The high performance gauge transmitter model EJ430 can be used to measure liquid, gas, or steam. It outputs a 4 to 20 m DC

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

Smart Two-wire Electromagnetic Flowmeter

Smart Two-wire Electromagnetic Flowmeter MagneW Two-wire PLUS + Smart Two-wire Electromagnetic Flowmeter Model MTG18A (Integral type) Model MTG14/MTG18B (Remote type) OVERVIEW The MagneW Two-wire PLUS + is a high performance electromagnetic flowmeter

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

Model 266GSH Gauge Model 266ASH Absolute. 2600T Series Pressure Transmitters Engineered solutions for all applications

Model 266GSH Gauge Model 266ASH Absolute. 2600T Series Pressure Transmitters Engineered solutions for all applications Data sheet DS/266GSH/ASH-EN Model 266GSH Gauge Model 266ASH Absolute 2600T Series Pressure Transmitters Engineered solutions for all applications Base accuracy from 0.06 % of calibrated span Reliable sensing

More information

Isolating Repeater Input Series 9163

Isolating Repeater Input Series 9163 > For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de

More information

Non-Submersible Industrial Pressure Transducer

Non-Submersible Industrial Pressure Transducer Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316

More information

Binary Output without Power Supply Series 9176

Binary Output without Power Supply Series 9176 Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

VortexMaster FSV430, FSV450 Vortex flowmeter

VortexMaster FSV430, FSV450 Vortex flowmeter Data Sheet DS/FSV430/450-EN Rev. D VortexMaster FSV430, FSV450 Vortex flowmeter Two-wire vortex flowmeter for measurement of the flow of gas, vapor and liquid Measurement made easy Intuitive operation

More information

General Specifications

General Specifications General Specifications odel EJ120 Differential Pressure Transmitter The high performance draft range differential transmitter model EJ120 outputs a 4 to 20 m DC signal corresponding to the measured differential.

More information

ProcessMaster, HygienicMaster FEX300, FEX500

ProcessMaster, HygienicMaster FEX300, FEX500 SM/FEX300/FEX500/FM/CSA-EN ProcessMaster, HygienicMaster FEX300, FEX500 FM / cfm Div. 1, Div. 2 Safety information for electrical equipment for potentially explosive areas in accordance with Factory Mutual

More information

User s Manual Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A

User s Manual Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A User s Manual Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A 12th Edition i Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A

More information

SVP3000 Alphaplus Smart Valve Positioner

SVP3000 Alphaplus Smart Valve Positioner No. SS2-AVP300-0100 (Rev.13) OVERVIEW SVP3000 Alphaplus Smart Valve Positioner Models AVP300 and AVP301 SVP3000 Alphaplus models AVP300 and AVP301 are current-pneumatic smart valve positioners. The SVP3000

More information

Installation guide 877 FDI Field Display & Interface

Installation guide 877 FDI Field Display & Interface Installation guide 877 FDI Field Display & Interface November 2008 Part no. 4416.264 Rev. 5 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com

More information

Smart Displacer Level (Interface) Transmitter DLT100 Series

Smart Displacer Level (Interface) Transmitter DLT100 Series Smart Displacer Level (Interface) Transmitter DLT100 Series Equipped with FISHER FIELDVUE DLC3010 1 Introduction DLT100 series is Smart Displacer Level (Interface) Transmitter equipped with the original

More information

OPTIWAVE 7300 C Supplementary instructions

OPTIWAVE 7300 C Supplementary instructions OPTIWAVE 7300 C Supplementary instructions Radar (FMCW) Level Transmitter for agitated liquids in process applications Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE 7300 C General

More information

VITO LT. Global Experience. Locally Applied. A dependable choice.

VITO LT. Global Experience. Locally Applied. A dependable choice. VITO LT A dependable choice. your accuracy requirements for tank inventory. Global Experience. Locally Applied. The VITO LT probe belongs to the VITO family for temperature and water bottom measurement.

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

Mass Flowmeter CoriolisMaster FCM2000

Mass Flowmeter CoriolisMaster FCM2000 Contents Data Sheet Mass Flowmeter CoriolisMaster FCM2000 Coriolis Mass Flowmeters are used for high precision measurement of mass flow and density. The fluid need not be electrically conductive. No moving

More information

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A

More information

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples

More information

AT200 External Mount Magnetostrictive Level Transmitter

AT200 External Mount Magnetostrictive Level Transmitter Data sheet DS/AT200-EN Rev. W AT200 External Mount Magnetostrictive Level Transmitter High accuracy liquid level and interface level detection K-TEK Level Products Measurement made easy Features Certified

More information

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output. Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision K FEATURES 4 to 20

More information

Mass Flowmeter CoriolisMaster FCM2000

Mass Flowmeter CoriolisMaster FCM2000 Contents Data Sheet Mass Flowmeter CoriolisMaster FCM2000 Coriolis Mass Flowmeters are used for high precision measurement of mass flow and density. The fluid need not be electrically conductive. No moving

More information

SMART TEMPERATURE TRANSMITTERS. smar

SMART TEMPERATURE TRANSMITTERS. smar SMART TEMPERATURE TRANSMITTERS FEATURES Single unit accepts signal from: - Standart RTDs and Thermocouples - Single ended or differential sensing - mv signals from radiation pyrometers, load cells, etc.

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

SLAMf Series. Data Sheet. Elastomer Sealed, Digital, Thermal Mass Flow Meters and Controllers. Overview. Product Description.

SLAMf Series. Data Sheet. Elastomer Sealed, Digital, Thermal Mass Flow Meters and Controllers. Overview. Product Description. DS-TMF-SLAMf-Series-RevB-MFC-eng August, 2017 Data Sheet SLAMf Series Model SLAMf Thermal Mass Flow Elastomer Sealed, Digital, Thermal Mass Flow Meters and Controllers Overview The SLA Series mass flow

More information

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications

More information

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter Data Sheet DS/FCB300/FCH300-EN Rev. H CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter 4-wire compact device For flow measurement of liquids and gases Measurement made easy CoriolisMaster

More information

M/SSL/SSR/E INSTRUCTION MANUAL SMART VALVE POSITIONER SSL & SSR SERIES

M/SSL/SSR/E INSTRUCTION MANUAL SMART VALVE POSITIONER SSL & SSR SERIES M/SSL/SSR/E 01 2009 INSTRUCTION MANUAL SMART VALVE POSITIONER SSL & SSR SERIES 1 - I N D E X - 1. Features.... P.3 11-6] Sub-Parameters... 2. Specifications 11-6-1] Changing Input Signal. P.15 3. Principle

More information

Relative and absolute pressure transmitter type 528

Relative and absolute pressure transmitter type 528 Relative and absolute pressure transmitter type 528 Pressure range -1... 0 60 bar Váš dodavatel: JSP, s.r.o. Raisova 547 506 01 Jičín JSP Měření a regulace www.jsp.cz tel.: +420 493 760 811 fax: +420 493

More information

Binary Output Series 9175

Binary Output Series 9175 Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use

More information

Condumax CLS21 and CLS21D

Condumax CLS21 and CLS21D Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:

More information

Fisher 4200 Series Electronic Position Transmitters

Fisher 4200 Series Electronic Position Transmitters Product Bulletin D200357012 4200 Series Transmitter Fisher 4200 Series Electronic Position Transmitters Fisher 4200 Series electronic position transmitters (figure 1 and 2) combine field-proven electronic

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HI Automação e Instrumentação, Lda. Rua Dr. Oliveira Salazar, nº 88 4780-453 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 809 124 Fax. +351 252 859 298

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology Level Plus Magnetostrictive Liquid-Level Transmitters with Temposonics Technology BRIEF OPERATION MANUAL FOR SAFE USE M-Series Model MR Analog Transmitter UNITED STATES GENERAL: Tel: +1-919-677-0100 Fax:

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Process Automation. Sensors and Systems:  Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Process Automation Accurate Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Flexible Sensors and Systems: www.fafnir.com Reliable FAFNIR Sensors and Systems Reliable,

More information

Technical Information Condumax CLS21D/CLS21

Technical Information Condumax CLS21D/CLS21 TI00085C/07/EN/14.14 71268310 Products Solutions Services Technical Information Condumax CLS21D/CLS21 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1.0 cm 1 Application

More information

TTF300 Field-mount temperature transmitter

TTF300 Field-mount temperature transmitter Change from one to two columns Data Sheet DS/TTF300-EN Rev. E TTF300 Field-mount temperature transmitter Temperature transmitter for all communication protocols. ABB common operating concept. Redundancy

More information

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers Series 9001 Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

Ult r a s o n i c le v e l me t e r s ULM 55

Ult r a s o n i c le v e l me t e r s ULM 55 Ult r a s o n i c le v e l me t e r s ULM 55 For continuous level measurement of liquids (even if polluted), mash and paste materials in open or closed vessels, sumps, open channels etc. Xi version for

More information

VortexMaster FSV430, FSV450 SwirlMaster FSS430, FSS450 Vortex and Swirl flowmeter

VortexMaster FSV430, FSV450 SwirlMaster FSS430, FSS450 Vortex and Swirl flowmeter Commissioning and safety instruction CI/FSV/FSS/430/450-EN Rev. G VortexMaster FSV430, FSV450 SwirlMaster FSS430, FSS450 Vortex and Swirl flowmeter Measurement made easy Change from one to two columns

More information