General Specifications

Size: px
Start display at page:

Download "General Specifications"

Transcription

1 General Specifications Model EJA3W and EJA3N Diaphragm Sealed Gauge Pressure Transmitters GS 1C22J3-E [Style: S2] Diaphragm seal is used to prevent process medium from entering directly into the pressure-sensing assembly of the pressure transmitter. It is connected to the transmitter using capillary filled with fill fluid. Models EJA3W and EJA3N Diaphragm Sealed Gauge Pressure Transmitters can be used to measure liquid, gas or steam pressure. They output a to 2 ma DC signal corresponding to the measured pressure. The models EJA3W and EJA3N feature remote setup and monitoring through communications with the model BT2/1 BRAIN TERMINAL, CENTUM CS/XL system etc. STANDARD SPECIFICATIONS Refer to GS 1C22T2-E for Fieldbus communication type marked with. Measurement Ranges : B Capsule A *1 EJA3W *1 EJA3N *1 Measurement Span.6 to 3 MPa {.6 to 3 kgf/cm 2 }.6 to 1 MPa {.6 to 1 kgf/cm 2 }.6 to 7 MPa {.6 to 7 kgf/cm 2 } Measurement Range -.1 to 3 MPa {-1 to 3 kgf/cm 2 } -.1 to 1 MPa {-1 to 1 kgf/cm 2 } -.1 to 7 MPa {-1 to 7 kgf/cm 2 } T1E.EPS *1: Measurement range is within the flange rating. Output Signal : to 2 ma DC, 2-wire system with digital communication Failure Alarm: Output status at CPU failure and hardware error; Up-scale: 11%, 21.6 ma DC or more(standard) Down-scale: -5%, 3.2 ma DC or less -2.5%, 3.6 ma DC or less (Optional code /F1) Note: Applicable for Output signal code D and E Supply Voltage : 1.5 to 2 V DC for general use and flameproof type 1.5 to 32 V DC for lightning protector (Optional code /A) 1.5 to 3 V DC for intrinsically safe, Type n, nonincendive, or non-sparking type 1.5 to 2 V DC for TIIS intrinsically safe type Conditions of Communication Line : Power supply voltage; 16. to 2 V DC Load resistance; See Figure 1. Note: In case of an intrinsically safe transmitter, external load resistance includes safety barrier resistance. Communication distance; 2 km, when CEV polyethylene-insulated PVC-sheathed control cables are used. Note: Communication distance varies depends on kind of cable. Load capacitance;.22 µf or less. Load inductance; 3.3 mh or less. Spacing from power line; 15 cm or more. Input impedance of receiver connected receiving resistance; 1 k or more at 2. khz (See Optional Specifications for Intrinsically safe type) Accuracy: See Table 2. Ambient Temperature Limits: - to 6 C (- to 1 F) (general-use type) -3 to 6 C (-22 to 1 F) (with integral indicator) (Note: The ambient temperature limits must be within the fill fluid operating temperature range, see table 1.) (See Optional Specifications for Explosion-protected types) Ambient Temperature Effect: See Table 2. Process Temperature Limits: See Table 1. (See Optional Specifications for Explosion-protected types) Ambient Humidity Limits: 5 to 1 % R.H.(at C) Working Pressure Limits: 2.7 kpa abs{2 mmhg abs}to max. measurement rangevalue. (Note: The working pressure must be within flange rating pressure.) For atmospheric pressure or below, see Figure 2. Power Supply Effect :.5 %/V (21.6 to 32 V DC, 35 ) Mounting: Transmitter; 2-inch pipe mounting Diaphragm seal; flange mounting Yokogawa Electric Corporation Nakacho, Musashino-shi, Tokyo, 1-75 Japan Phone: Fax: GS 1C22J3-E Copyright July th Edition Mar. 26

2 Mounting Flange Rating: See Model and Suffix Codes. Flange conforming to ANSI are serrated on the gasket surfaces (ANSI B16.5) Note: For model EJA3W wetted parts material code H, T, or U, no serration is worked. Degrees of Protection: IP67, NEMAX, JIS C92 immersion proof Explosion-protected Construction: See Optional Specification. Electrical Connection: See Model and Suffix Codes. Amplifier Housing: Cast aluminum alloy or JIS SCS1A stainless steel (optional) Painting: Polyurethance resin baked finish Deep sea moss green (Munsell.6GY3.1/2.) Integral Indicator: LCD digital indicator (optional) Transmitter Material: Cover flange; JIS SCS1A Cover flange bolts; See Model and Suffix Codes. Diaphragm Seal Material: Diaphragm and other wetted parts; See Model and Suffix Codes. Capillary tube; JIS SUS316 Protection tube; JIS SUS3 PVC-sheathed (Max. operating temperature of PVC, 1 C (212 F)) Fill fluid; See Table 1. < Settings When Shipped > Tag Number Output Mode Display Mode Operation Mode Damping Time Constant As specified in order *1 Linear Linear Normal unless otherwise specified in order 2 sec. Damping Time Constant: (Sum of time constants for amplifier assembly and capsule assembly with diaphragm seal) Amplifier assembly time constant; Can be set in 9 increments from.2 to 6 sec. Capsule assembly time constant; Capsule A B Time Constant Approx. Approx. (sec).2.2 T2E.EPS Approximate values obtained at normal temperature when the capillary length is 5 m, process flange size/material code A, B, C and the fill fluid code is A. External Zero Adjustment : Continuously adjustable Resolution;.1 % of span Zero Adjustment Limits: Zero can be fully elevated or suppressed as long as low and high range values are within the measurement range low and high limits of the capsule. Tag Plate: JIS SUS3. Weight:.3 kg (1.3 lb) Model EJA3W with 5 mm JIS 1K flange, capillary length 5 m; with integral indicator and mounting bracket. 13. kg (29.6 lb) Model EJA3N with 1 mm JIS 1K flange, X 2 =1, capillary length 5 m; with integral indicator and mounting bracket. Add 1. kg (3.1 lb) for JIS SCS1A stainless steel amplifier housing. EMC Conformity Standards:, EN61326, AS/NZS CISPR11 European Pressure Equipment Directive 97/23/EC: Sound Engineering Practice Calibration Range Lower Range Value Calibration Range Higher Range Value Calibration Range Units As specified in order 2 As specified in order Selected from mmh 2 O, mmaq, mmwg, mmhg, Pa, hpa, kpa, MPa, mbar, bar, gf/cm 2, kgf/cm 2, inh 2 O, inhg, fth 2 O, or psi. (Only one unit can be specified) *1: Up to 16 alphanumeric characters (including - and ) will be entered in the amplifier memory. T5E.EPS Process Temperature *1 Ambient temperature *2 Fill Fluid Code A -1 to 25 C ( 1 to 2 F ) -1 to 6 C ( 1 to 1 F ) Table 1. Process Temperature and Ambient Temperature Fill Fluid Code B -3 to 1 C ( -22 to 356 F ) -15 to 6 C ( 5 to 1 F ) Fill Fluid Code C 1 to 3 C ( 5 to 572 F ) 1 to 6 C ( 5 to 1 F ) Working pressure See Figure 2 Specific gravity * Silicone Oil Fluorinated Oil Ethylene Glycol Fill Fluid Code D -2 to 12 C ( - to 2 F ) -1 to 6 C ( 1 to 1 F ) 51 kpa abs or more {3 mmhg abs} Fill Fluid Code E -5 to 1 C ( -5 to 212 F ) - to 6 C ( - to 1 F ) Vacuum pressure not allowed 1.9 to *1: See Figure 2 Working Pressure and Process Temperature. *2: This ambient temperature is the transmitter ambient temperature. *3: Approximate values at a temperature of 25 C (77 F) *: The pressure transmitter should be installed at least 7 mm below the process connection. However, this value (7 mm) may be affected by ambient temperature, operating pressure, fill fluid or material of the wetted diaphragm. Contact YOKOGAWA when the transmitter can not be installed at least 7 mm below the process connection. T6E.EPS All Rights Reserved. Copyright 199, Yokogawa Electric Corporation GS 1C22J3-E Mar. 23, 26-

3 3 6 External load resistance 25 R ( ) R= E Digital Communication range BRAIN and HART Power supply voltage E (V DC) F1E.EPS Figure 1. Relationship Between Power Supply Voltage and External Load Resistance Process temperature for fill fluid code B Transmitter ambient temperature range (For fill fluid code A, B) 1 {75} Working pressure kpa abs {mmhg abs} 1 {75} 2.7 {2} Process temperature for fill fluid code A Process temperature for fill fluid code C Flange max. working pressure Atmospheric pressure 1 {7.5}.1 {.75} Process Temperature ( C) Figure 2. Woirking Pressure and Process Temperature F2E.EPS Table 2. Accuracy and Ambient Temperature Effect (As percent of x ) *1 Capsule A, B (For wetted parts material code S) A, B (For wetted parts material code H, T, and U) Accuracy ±.2 % ± ( Pref x ) % For x Pref For x < Pref ±.2 % ± ( Pref x ) % For x Pref For x < Pref Ambient temperature effect *2 Zero shift Total shift Pref ± ( x ) % / 5 C ± 1. % / 5 C Pref ± ( x ) % / 5 C For x Pref For x < Pref Pref ± ( x ) % / 5 C ± 1.6 % / 5 C Pref ± (. +. x ) % / 5 C For x Pref For x < Pref T7E.EPS *1: x is the highest value among the absolute value of the lower range value (LRV) and higher range value (HRV), and the span value in a calibration range. x Percent of span = Percent of x span *2: In case of 6 to 1 m. for capillary length, value of ambient temperature effect is twice that given in the table. The ambient temperature effect specification applies to the range of to 6 C (32 to1 F). (Below C (32 F), value is three times that given in the table.) Table 3. Value of Pref Capsule A B Pref.3 MPa {3 kgf/cm 2 } 1. MPa {1 kgf/cm 2 } TE.EPS All Rights Reserved. Copyright 199, Yokogawa Electric Corporation GS 1C22J3-E Mar. 23, 26-

4 MODEL AND SUFFIX CODES Model EJA3W [Flange size: 2-inch (5 mm) and 3-inch ( mm)] Model Suffix Codes Description D E F A B EJA3W Output Signal Measurement span (capsule) Wetted parts material * Process flange rating Process flange size / material Cover flange bolts material Fill fluid Capillary length (m) Installation Electrical connection Integral indicator Mounting bracket Optional codes S H T U J J J J A A A P P P D D D A B C D E F A B A * B * C D * E A * D E N A B N / Optional specification Diaphragm Sealed Gauge Pressure transmitter (Flush diaphragm type) to 2 ma DC with digital communication (BRAIN protocol) to 2 ma DC with digital communication (HART protocol) *1 Digital communication (FOUNDATION Fieldbus protocol) *6.6 to 3 MPa {.6 to 3 kgf/cm 2 }{.6 to 3 psi}{.6 to 3 bar}.6 to 1 MPa {.6 to 1 kgf/cm 2 }{66 to 2 psi}{.6 to 1 bar} [Diaphragm] [Others] JIS SUS316L JIS SUS316L Hastelloy C-276 *9 Hastelloy C-276 *9 Tantalum Tantalum Titanium Titanium JIS 1K JIS 2K JIS K JIS 63K ANSI Class 15 ANSI Class 3 ANSI Class 6 JPI Class 15 JPI Class 3 JPI Class 6 DIN PN1/16 DIN PN25/ DIN PN6 2-inch (5 mm) / JIS S25C 2-inch (5 mm) / JIS SUS3 2-inch (5 mm) / JIS SUS316 3-inch ( mm) / JIS S25C 3-inch ( mm) / JIS SUS3 3-inch ( mm) / JIS SUS316 JIS SCM35 JIS SUS63 For general use (silicone oil) For general use (silicone oil) [Process temp.] [Ambient temp.] -1 to 25 C -1 to 6 C -3 to 1 C -15 to 6 C For high temperature use (silicone oil) 1 to 3 C 1 to 6 C For oil-prohibited use (fluorinated oil) -2 to 12 C -1 to 6 C For low temperature use (ethylene glycol) -5 to 1 C - to 6 C Always A Specify capillary length from 1 to 1 m in. (Example for 2 m : 2) Horizontal impulse piping type, left side high pressure G1/2 female, one electrical connection 1/2 NPT female, two electrical connections without blind plug Pg 13.5 female, two electrical connections without blind plug M2 female, two electrical connections without blind plug G1/2 female, two electrical connections and a blind plug 1/2 NPT female, two electrical connections and a blind plug Pg 13.5 female, two electrical connections and a blind plug M2 female, two electrical connections and a blind plug Digital indicator Digital indicator with the range setting switch *7 (None) JIS SECC 2-inch pipe mounting (flat type) JIS SUS3 2-inch pipe mounting (flat type) (None) The marks indicate the most typical selection for each specification. Example: EJA3W-DASA1AA-AA2-92NA/ T9E.EPS All Rights Reserved. Copyright 199, Yokogawa Electric Corporation GS 1C22J3-E Mar. 23, 26-

5 5 *1: Refer to GS 1C22T1-E for HART Protocol version. *2: In case of Wetted parts material code T (Tantalum), the process temperature limit is -1 to 2 C. *3: Wetted parts material code T (Tantalum) cannot be applied. *: Even in case where Fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify Optional code K1 or K5. *5: In case of Wetted parts material code H (Hastelloy C), T (Tantalum), and U (Titanium) or Fill fluid code C (for high temperature use), specify capillary length from 1 to 5 m. *6: Refer to GS 1C22T2-E for Fieldbus communication. *7: Not applicable for Output signal code F. *: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 C [32 F] or above). Contact Yokogawa for detailed information of the wetted parts material. *9: Hastelloy C-276 or ASTM N1276. All Rights Reserved. Copyright 199, Yokogawa Electric Corporation GS 1C22J3-E Mar. 23, 26-

6 6 Model EJA3N [Flange size: -inch (1 mm)] EJA3N Output Signal Measurement span (capsule) Wetted parts material *7 Flange rating Diaphragm extension length Process flange size / material Cover flange bolts material Fill fluid Model Suffix Codes Description D E F A B Capillary length (m) *3 *5 Installation Electrical connection Integral indicator Mounting bracket Optional codes S J J J A A P P D D G H J A B A B C D * E B D E N A B N Diaphragm sealed gauge pressure transmitter (Extended diaphragm type) to 2 ma DC with digital communication (BRAIN protocol) to 2 ma DC with digital communication (HART protocol) *1 Digital communication (FOUNDATION Fieldbus protocol) *.6 to 3 MPa {.6 to 3 kgf/cm 2 }{.6 to 3 psi}{.6 to 3 bar}.6 to 7 MPa {.6 to 7 kgf/cm 2 }{66 to 1 psi}{.6 to 7 bar} [Diaphragm] [Pipe] [Others] JIS SUS316L JIS SUS316 JIS SUS316 JIS 1K JIS 2K JIS K ANSI Class 15 ANSI Class 3 JPI Class 15 JPI Class 3 DIN PN1/16 DIN PN25/ X 2 = 5 mm X 2 = 1 mm X 2 = 15 mm -inch (1 mm) / JIS S25C -inch (1 mm) / JIS SUS3 -inch (1 mm) / JIS SUS316 JIS SCM35 JIS SUS63 [Process tempe.] [Ambient tempe.] For general use (silicone oil) -1 to 25 C -1 to 6 C For general use (silicone oil) -3 to 1 C -15 to 6 C For high temperature use (silicone oil) 1 to 3 C 1 to 6 C For oil-prohibited use (fluorinated oil) -2 to 12 C -1 to 6 C For low temperature use (ethylene glycol) -5 to 1 C - to 6 C Always B Specify capillary length from 1 to 1 m in. (Example for 2 m : 2) Horizontal impulse piping type, left side high pressure G1/2 female, one electrical connection 1/2 NPT female, two electrical connections without blind plug Pg 13.5 female, two electrical connections without blind plug M2 female, two electrical connections without blind plug G1/2 female, two electrical connections and a blind plug 1/2 NPT female, two electrical connections and a blind plug Pg 13.5 female, two electrical connections and a blind plug M2 female, two electrical connections and a blind plug Digital indicator Digital indicator with the range setting switch *6 (None) JIS SECC 2-inch pipe mounting (flat type) JIS SUS3 2-inch pipe mounting (flat type) (None) / Optional specification The marks indicate the most typical selection for each specification. Example: EJA3N-DASA12GA-AB2-92NA/ *1: Refer to GS 1C22T1-E for HART Protocol version. *2: Even in case where Fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify Optional code K1 or K5. *3: In case of Fill fluid code C (for high temperature use), specify capillary length from 1 to 5 m. *: Refer to GS 1C22T2-E for Fieldbus communication. *5: The specified capillary length includes the diaphragm extension length(x 2 ) and the flange thickness(t). *6: Not applicable for Output signal code F. *7: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 C [32 F] or above). Contact Yokogawa for detailed information of the wetted parts material. T1E.EPS All Rights Reserved. Copyright 199, Yokogawa Electric Corporation GS 1C22J3-E Mar. 23, 26-

7 7 Model EJA3N [Flange size: 3-inch (mm)] Model Suffix Codes Description D E EJA3N Output Signal -F Measurement span (capsule) A B Wetted parts material *5 S Flange rating J J J A A P P D D Diaphragm extension length Process flange size / material D E F Cover flange bolts material A B Fill fluid Capillary length (m) *3 Installation Electrical connection Integral indicator Mounting bracket Optional codes Diaphragm sealed gauge pressure transmitter (Extended diaphragm type) to 2 ma DC with digital communication (BRAIN protocol) to 2 ma DC with digital communication (HART protocol) *1 Digital communication (FOUNDATION Fieldbus protocol) *2.6 to 3 MPa {.6 to 3 kgf/cm 2 }{.6 to 3 psi}{.6 to 3 bar}.6 to 7 MPa {.6 to 7 kgf/cm 2 }{66 to 1 psi}{.6 to 7 bar} [Diaphragm] [Pipe] [Others] JIS SUS316L JIS SUS316 JIS SUS316 JIS 1K JIS 2K JIS K ANSI Class 15 ANSI Class 3 JPI Class 15 JPI Class 3 DIN PN1/16 DIN PN25/ X 2 =5 mm X 2 =1 mm X 2 =15 mm 3-inch ( mm) / JIS S25C 3-inch ( mm) / JIS SUS3 3-inch ( mm) / JIS SUS316 JIS SCM35 JIS SUS63 [Process temp.] [Ambient temp.] -A For general use (silicone oil) -1 to 25 C -1 to 6 C -B For general use (silicone oil) -3 to 1 C -15 to 6 C B Always B Specify capillary length from 1 to 5 m in. (Example for 2 m : 2) Horizontal impulse piping type, left side high pressure G1/2 female, one electrical connection /2 NPT female, two electrical connections without blind plug Pg 13.5 female, two electrical connections without blind plug M2 female, two electrical connections without blind plug G1/2 female, two electrical connections and a blind plug /2 NPT female, two electrical connections and a blind plug Pg 13.5 female, two electrical connections and a blind plug M2 female, two electrical connections and a blind plug D Digital indicator E Digital indicator with the range setting switch * N (None) A JIS SECC 2-inch pipe mounting (flat type) B JIS SUS3 2-inch pipe mounting (flat type) N (None) / Optional specification The marks indicate the most typical selection for each specification.example: EJA3N-DASA12DA-AB2-92NA/ T11E.EPS *1: Refer to GS 1C22T1-E for HART Protocol version. *2: Refer to GS 1C22T2-E for Fieldbus communication. *3: The specified capillary length includes the diaphragm extension length(x 2 ) and the flange thickness(t). *: Not applicable for Output signal code F. *5: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (15 C [32 F] or above). Contact Yokogawa for detailed information of the wetted parts material. All Rights Reserved. Copyright 199, Yokogawa Electric Corporation GS 1C22J3-E Mar. 23, 26-

8 OPTIONAL SPECIFICATIONS (For Explosion Protected Types ) For FOUNDATION Fieldbus explosion protected type, see GS 1C22T2-E. Factory Mutual (FM) CENELEC ATEX Item Description Code FM Explosionproof Approval *1 *3 Applicable standard: FM36, FM3615, FM31, ANSI/NEMA25 Explosionproof for Class I, Division 1, Groups B, C and D Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G Hazardous (classified) locations, indoors and outdoors (NEMA X) Division 2, 'SEALS NOT REQUIRED', Temp. Class: T6 Amb. Temp.: to 6 C ( to 1 F) FM Intrinsically safe Approval *1 *3 Applicable standard: FM36, FM361, FM3611, FM31, ANSI/NEMA25 Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G and Class III, Division 1 Hazardous Locations. Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2, Groups E, F & G, and Class III, Division 1 Hazardous Locations. Enclosure: NEMA X, Temp. Class: T, Amb. Temp.: to 6 C ( to 1 F) Intrinsically Safe Apparatus Parameters [Groups A, B, C, D, E, F and G] Vmax=3 V, Imax=165 ma, Pmax=.9 W, Ci=22.5 nf, Li=73 H [Groups C, D, E, F and G] Vmax=3 V, Imax=225 ma, Pmax=.9 W, Ci=22.5 nf, Li=73 H Combined FF1 and FS1 *1 *3 CENELEC ATEX (KEMA) Flameproof Approval *2 *3 Applicable standard: EN51, EN51, EN Certificate: KEMA 2ATEX21 II 2G EExd IIC T, T5, T6 Amb. Temp.: T5; to C ( to 176 F), T and T6; to 75 C ( to 167 F) Max. process Temp.: T; 12 C (2 F), T5; 1 C (212 F), T6; 5 C (15 F) CENELEC ATEX (KEMA) Intrinsically safe Approval *2 *3 Applicable standard: EN51, EN52, EN52, EN Certificate: KEMA 2ATEX13X II 1G EEx ia IIC T, Amb. Temp.: to 6 C ( to 1 F) Ui=3 V, Ii=165 ma, Pi=.9 W, Ci=22.5 nf, Li=73 H Combined KF2, KS2 and Type n *2 *3 Type n Applicable standard: EN521 II 3G Ex nl IIC T, Amb. Temp.: to 6 C ( to 1 F) Ui=3 V DC, Ci=22.5 nf, Li=73 H Dust II 1D maximum surface temperature T65 C (19 F) {Tamb.: C (1 F)}, T5 C (15 F) {Tamb.: 6 C (1 F)}, T15 C (221 F) {Tamb.: C (176 F)} *1: Applicable for Electrical connection code 2 and 7 (1/2 NPT female). *2: Applicable for Electrical connection code 2,, 7 and 9 (1/2 NPT and M2 female). *3: Applicable for Output signal code D and E. For intrinsically safe approval, use the safety barrier certified by the testing laboratories (BARD- is not applicable). FF1 FS1 FU1 KF2 KS2 KU2 T1E.EPS All Rights Reserved. Copyright 199, Yokogawa Electric Corporation GS 1C22J3-E Mar. 23, 26-

9 9 Canadian Standards Association (CSA) IECEx Scheme * TIIS certification Attached flameproof packing adapter *5 Item Description Code CSA Explosionproof Approval *1 *3 Applicable standard: C22.2 No., No.., No. 25, No. 3, No. 9, No. 12 Certificate: 1959 Explosionproof for Class I, Division 1, Groups B, C and D Dustignitionproof for Class II/III, Division 1, Groups E, F and G Division2 SEALS NOT REQUIRED, Temp. Class: T, T5, T6 Encl Type x Max. Process Temp.: T; 12 C (2 F), T5; 1 C (212 F), T6; 5 C (15 F) Amb. Temp.: to C ( to 176 F) CSA Intrinsically safe Approval *1 *3 Applicable standard: C22.2 No., No.., No. 25, No. 3, No. 9, No. 12, No. 157, No. 213 Certificate: 1533 Class I, Groups A, B, C and D Class II and III, Groups E, F and G Encl Type x, Temp. Class: T, Amb. Temp.: to 6 C ( to 1 F) Vmax=3 V, Imax=165 ma, Pmax=.9 W, Ci=22.5 nf, Li=73 H Combined CF1 and CS1 *1 *3 IECEx Intrinsically safe, type n and Flameproof Approval *3 *9 Intrinsically safe and type n Applicable Standard: IEC 679-:2, IEC :1999, IEC :25, IEC :25 Certificate: IECEx KEM 6.7X Ex ia IIC T, Ex nl IIC T Enclosure: IP67 Amb. Temp.: to 6 C ( to 1 F), Max. Process Temp.: 12 C (2 F) Electrical Parameters: [Ex ia] Ui=3 V, Ii=165 ma, Pi=.9 W, Ci=22.5 nf, Li=73 H [Ex nl] Ui=3 V, Ci=22.5 nf, Li=73 H Flameproof Applicable Standard: IEC 679-:2, IEC679-1:23 Certificate: IECEx KEM 6.5 Ex d IIC T6...T Enclosure: IP67 Max.Process Temp.: T;12 C (2 F), T5;1 C (212 F), T6; 5 C (15 F) Amb.Temp.: to 75 C ( to 167 F) for T, to C ( to 176 F) for T5, to 75 C ( to 167 F) for T6 TIIS Flameproof Approval, Ex do IIC TX *3 *5 *7 * Certificate: C15296 (Without integral indicator) C15297 (With integral indicator) Amb. Temp.: 2 to 6 C, Process Temp.: 2 to 12 C TIIS Intrinsically safe Approval, Ex ia IIC T *6 * Certificate: C1632 Amb. Temp.: 2 to 6 C, Process Temp.: 2 to 12 C Electrical connection: G1/2 female Applicable cable: O. D. to 12 mm 1 pc. 2 pcs. *1: Applicable for Electrical connection code 2 and 7 (1/2 NPT female). *2: Applicable for Electrical connection code 2,, 7 and 9 (1/2 NPT and M2 female). *3: Applicable for Output signal code D and E. For intrinsically safe approval, use the safety barrier certified by the testing laboratories (BARD- is not applicable). *: Applicable only for Australia and New Zealand area. *5: If cable wiring is to be used to a TIIS flameproof type transmitter, add the YOKOGAWA-assured flameproof packing adapter. *6: Applicable for Output signal code D. See <Safety Barrier for TIIS Intrinsically Safe Type>. *7: In case that the ambient temperature exceeds 5 C or that the ambient temperature exceeds 5 C with the process temperature of 9 C or above, use heat-resistant cables with maximum allowable temperature of 75 C or above. *: TIIS (The Technology Institution of Industrial Safety) Certification is a new notation for the explosionproof approval in Japan instead of JIS. *9: Applicable for Electrical connection code 2, and 7 (1/2 NPT and M2 female). CF1 CS1 CU1 SU2 FS3 JS3 G11 G12 T16E.EPS All Rights Reserved. Copyright 199, Yokogawa Electric Corporation GS 1C22J3-E Mar. 23, 26-

10 1 OPTIONAL SPECIFICATIONS Item Description Code Amplifier cover only P Color change Painting * Amplifier cover and terminal cover, Munsell 7.5 R/1 PR Coating change Epoxy resin-baked coating *9 Transmitter power supply voltage : 1.5 to 32 V DC ( 1.5 to 2 V DC for TIIS intrinsically safe X1 Lightning protector type, 1.5 to 3 V DC for intrinsically safe type other than TIIS, or 9 to 32 V DC for Fieldbus communication type.) Allowable current : Max. 6 A (1 s), Repeating 1 A (1 s) 1 times A Oil-prohibited use Oil-prohibited use with dehydrating treatment Degrease cleansing treatment Degrease cleansing treatment and dehydrating treatment K1 K5 No serration *1 No serration work on the flange gasket surface ( for ANSI flange only ) Q Teflon film Operating temperature correction *2 Fast response *6 Failure alarm down-scale *3 NAMUR NE3 compliant *3 *7 Stainless steel amplifier housing * Gold-plate Stainless steel tag plate Capillary without PVC sheaths Calibration units *5 Sealing treatment to JIS SUS63 nuts Diaphragm protection from sticky process fluid by FEP Teflon film attached with fluorinated oil. Operation range: 2 to 15 C, to 2 MPa(Not applicable for vacuum service). Adjusting range : C to Maximum temperature of specified fill fluid Update time:.125 sec or less Amplifier assembly damping time constant:.1 to 6 sec in 9 increments. Response time (with min. damping time constant): max..3 sec (excluding diaphragm seal units) Output status at CPU failure and hardware error is 5%, 3.2 ma or less. Output signal limits: 3. ma to 2.5 ma Failure alarm down-scale: output status at CPU failure and hardware error is 5%, 3.2 ma or less. Failure alarm up-scale: output status at CPU failure and hardware error is 11%, 21.6 ma or more. Amplifier housing material : JIS SCS1A stainless steel (equivalent to JIS SUS316 cast stainless steel or ASTM CF-M) Inside of isolating diaphragms(fill fluid side) are gold plated, effective for hydrogen permeation. ( applicable for Wetted parts material code S and H ) 3SST tag plate wired onto transmitter When ambient temperature exceeds 1 C, or use of PVC is prohibited P calibration ( psi unit ) bar calibration ( bar unit ) (See Table.) M calibration (kgf/cm 2 unit ) Sealant(liquid silicone rubber) is coated on JIS SUS63 cover flange mounting nuts against stress corrosion cracking. *1: This item cannot be applied to model EJA3W Wetted part material code H, T, or U, whose gasket contact surface are not serrated as standard specifications. *2: Specify the process operating temperature for zero correction. Example: Zero correction by process temperature 9 C. *3: Applicable for Output signal code D and E. The hardware error indicates faulty amplifier or capsule. When combining with Option code F1, output status for down-scale is 2.5%, 3.6 ma DC or less. *: Applicable for Electrical connection code 2, 3,, and 7. Not applicable for Option code P and X1. *5: The unit of MWP (Max. working pressure) on name plate of a housing is the same unit as specified by Option code D1, D3, and D. *6: Applicable for Output signal code D and E. *7: Not applicable for Option code C1. *: Standard polyurethan painting can be used in acid atmosphere, whereas the epoxy resin-baked coating (Option code X1) can be used in alkaline atmosphere. Anti-corrosion coating, the combination of polyurethan and epoxy resin-baked coating, is available by special order as sea water, alkaline, and acid resistant. *9: Not applicable for color change option. T R F1 C1 C2 C3 E1 A1 N V D1 D3 D Y T13E.EPS Table. Calibration Units EJA3W Measurement Span and Range D1 ( psi Unit ) A B Span Range Span Range.6 to 3 psi -15 to 3 psi 66 to 2 psi -15 to 2 psi Optional Code D3 ( bar Unit ).6 to 3 mbar -1 to 3 mbar.6 to 1 mbar -1 to 1 mbar D ( kgf/cm 2 Unit ).6 to 3 kgf/cm 2-1 to 3 kgf/cm 2.6 to 1 kgf/cm 2-1 to 1 kgf/cm 2 EJA3N Measurement Optional Code Span and Range D1 ( psi Unit ) D3 ( bar Unit ) D ( kgf/cm 2 Unit ) Span.6 to 3 psi.6 to 3 mbar.6 to 3 kgf/cm 2 A Range Span -15 to 3 psi 66 to 1 psi -1 to 3 mbar.6 to 7 mbar -1 to 3 kgf/cm 2.6 to 7 kgf/cm 2 B Range -15 to 1 psi -1 to 7 mbar -1 to 7 kgf/cm 2 T12E.EPS All Rights Reserved. Copyright 199, Yokogawa Electric Corporation GS 1C22J3-E Mar. 23, 26-

11 11 Item Description Code Mill Certificate Process flange, Block For model EJA3W M5 Process flange, Block, Pipe, Base For model EJA3N M6 ( Flange rating ) ( Test Pressure ) (Applicable model) Pressure test/leak test Certificate *1 JIS 1K 2 MPa {2 kgf/cm 2 } T1 JIS 2K JIS K JIS 63K 3 MPa {3 kgf/cm 2 } 3 MPa {3 kgf/cm 2 } 3 MPa {3 kgf/cm 2 } EJA3W/EJA3N EJA3W T2 T3 T5 ANSI/JPI Class 15 3 MPa {29. kgf/cm 2 } T6 EJA3W/EJA3N ANSI/JPI Class 3 3 MPa {3 kgf/cm 2 } T7 ANSI/JPI Class 6 3 MPa {3 kgf/cm 2 } EJA3W Nitrogen (N 2 ) Gas *2 T9 JIS 1K 2 MPa {2 kgf/cm 2 } T31 5 MPa {5 kgf/cm 2 EJA3W/EJA3N Retention time: JIS 2K } 1 minutes T32 JIS K JIS K JIS 63K ANSI/JPI Class 15 ANSI/JPI Class 3 ANSI/JPI Class 3 ANSI/JPI Class 6 1 MPa {1 kgf/cm 2 } 7 MPa {7 kgf/cm 2 } 1 MPa {1 kgf/cm 2 } 3 MPa {29. kgf/cm 2 } 7.7 MPa {77 kgf/cm 2 } 7 MPa {7 kgf/cm 2 } 1 MPa {1 kgf/cm 2 } EJA3W EJA3N EJA3W EJA3W/EJA3N EJA3W EJA3N EJA3W T33 T3 T35 T36 T37 T3 T39 For A-capsule For B-capsule *1: The unit on the certificate is always MPa regardless of selection of option code D1, D3, or D. *2: Pure nitrogen gas is used for oil-prohibited use (Option code K1 and K5 ). T15E.EPS All Rights Reserved. Copyright 199, Yokogawa Electric Corporation GS 1C22J3-E Mar. 23, 26-

12 12 DIMENSIONS Model EJA3W Unit : mm (approx. inch) ød *1 25 (.9) t f 3 (1.3) øg øc ød n-øh External indicator conduit connection (Optional) 1(5.51) 9(3.7) Conduit connection Internal indicator (Optional) ø7 (3.7) 11 (.33) 12 (.7) Terminal side Wetted parts material code U (Titanium) 197(7.76) Ground terminal 16(5.75) 333(13.11) 12 (.) 92 (3.62) Shrouding bolt *2 Zero adjustment Open to atmosphere (ø5mm) 7 (1.5) 2-inch pipe (O.D. 6.5mm) *1: Indicates inside diameter of gasket contact surface. *2: Applicable only for ATEX, IECEx, and TIIS Flameproof type. Process flange size : 3 inch ( mm) Mounting bracket (Flat-type, Optional) Flange Rating ød øc øg ød t f * n øh JIS 1K 15(7.2) 15(5.91) 13(5.12) 9(3.5) 1(.71) 19(.75) JIS 2K 2(7.7) 16(6.3) 13(5.12) 9(3.5) 22(.7) 23(.91) JIS K 21(.27) 17(6.69) 13(5.12) 9(3.5) 32(1.26) 23(.91) JIS 63K 23(9.6) 15(7.2) 13(5.12) 9(3.5) (1.57) 25(.9) ANSI Class (7.5) 152.(6) 13(5.12) 9(3.5) 23.9(.9) 1.6(.6) 19.1(.75) ANSI Class (.25) 16.1(6.62) 13(5.12) 9(3.5) 2.5(1.12) 1.6(.6) 22.(.) ANSI Class (.25) 16.1(6.62) 13(5.12) 9(3.5) 3.2(1.5) 6.(.25) 22.(.) JPI Class 15 19(7.) 152.(6) 13(5.12) 9(3.5) 2(.9) 1.6(.6) 19(.75) JPI Class 3 21(.27) 16.1(6.62) 13(5.12) 9(3.5) 2.5(1.12) 1.6(.6) 22(.7) JPI Class 6 21(.27) 16.1(6.62) 13(5.12) 9(3.5) 3.(1.51) 6.(.25) 22(.7) DIN PN 1/16 2(7.7) 16(6.3) 13(5.12) 9(3.5) 2(.79) 1(.71) DIN PN 25/ 2(7.7) 16(6.3) 13(5.12) 9(3.5) 2(.9) 1(.71) DIN PN 6 215(.6) 17(6.69) 13(5.12) 9(3.5) 2(1.1) 22(.7) Process flange size : 2 inch (5 mm) Flange Rating ød øc øg ød t f * n øh JIS 1K 155(6.1) 12(.72) 1(3.9) 61(2.) 16(.63) 19(.75) JIS 2K 155(6.1) 12(.72) 1(3.9) 61(2.) 1(.71) 19(.75) JIS K 165(6.5) 13(5.12) 1(3.9) 61(2.) 26(1.2) 19(.75) JIS 63K 15(7.2) 15(5.12) 1(3.9) 61(2.) 3(1.3) 23(.91) ANSI Class (6.) 12.7(.75) 1(3.9) 61(2.) 19.1(.75) 1.6(.6) 19.1(.75) ANSI Class (6.5) 127.(5.) 1(3.9) 61(2.) 22.(.) 1.6(.6) 19.1(.75) ANSI Class (6.5) 127.(5.) 1(3.9) 61(2.) 31.(1.25) 6.(.25) 19.1(.75) JPI Class (6.1) 12.6(.75) 1(3.9) 61(2.) 19.5(.77) 1.6(.6) 19(.75) JPI Class 3 165(6.5) 127.(5.) 1(3.9) 61(2.) 22.5(.9) 1.6(.6) 19(.75) JPI Class 6 165(6.5) 127.(5.) 1(3.9) 61(2.) 31.9(1.26) 6.(.25) 19(.75) DIN PN 1/16 165(6.5) 125(.92) 1(3.9) 61(2.) 1(.71) 1(.71) DIN PN 25/ 165(6.5) 125(.92) 1(3.9) 61(2.) 2(.7) 1(.71) DIN PN 6 1(7.9) 135(5.31) 1(3.9) 61(2.) 26(1.2) 22(.7) * In case where process flange material is JIS S25C, value of f is. F3E.EPS All Rights Reserved. Copyright 199, Yokogawa Electric Corporation GS 1C22J3-E Mar. 23, 26-

13 13 Model EJA3N ød øc øg X2 øa 1 (.55) f t Unit : mm (approx. inch) 1(5.51) 12 (.72) ø3 (1.1) n-øh External indicator conduit connection (Optional) 9(3.7) Conduit connection Internal indicator (Optional) ø7 (3.7) 11 (.33) 12 (.7) Terminal side 197(7.76) Ground terminal 16(5.75) 333(13.11) 12 (.) 92 (3.62) Shrouding bolt *1 Zero adjustment Open to atmosphere (ø5mm) 7 (1.5) 2-inch pipe (O.D. 6.5mm) Mounting bracket (Flat-type, Optional) *1: Applicable only for ATEX, IECEx, and TIIS Flameproof type. Process flange size : inch (1 mm) Diaphramg extension length code 2 : X 2 = 5 mm (2 inch) : X 2 = 1 mm ( inch) 6 : X 2 = 15 mm (6 inch) Flange Rating ød øc øg øa t f * n øh JIS 1K 21(.72) 175(6.9) 155(6.1) 96±.5(3.7) 1(.71) 19(.75) JIS 2K 225(.6) 15(7.2) 155(6.1) 96±.5(3.7) 2(.9) 23(.91) JIS K 25(9.) 25(.7) 155(6.1) 96±.5(3.7) 36(1.2) 25(.9) ANSI Class (9.) 19.5(7.5) 155(6.1) 96±.5(3.7) 23.9(.9) 1.6(.6) 19.1(.75) ANSI Class 3 25(1.) 2.2(7.) 155(6.1) 96±.5(3.7) 31.(1.25) 1.6(.6) 22.(.) JPI Class (9.2) 19.5(7.5) 155(6.1) 96±.5(3.7) 2(.9) 1.6(.6) 19(.75) JPI Class 3 25(1.) 2.2(7.) 155(6.1) 96±.5(3.7) 32(1.26) 1.6(.6) 22(.7) DIN PN 1/16 22(.66) 1(7.9) 155(6.1) 96±.5(3.7) 2(.79) 1(.71) DIN PN 25/ 235(9.25) 19(7.) 155(6.1) 96±.5(3.7) 2(.9) 22(.7) Process flange size : 3 inch ( mm) Flange Rating ød øc øg øa t f * n øh JIS 1K 15(7.2) 15(5.91) 13(5.12) 71±.5(2.) 1(.71) 19(.75) JIS 2K 2(7.7) 16(6.3) 13(5.12) 71±.5(2.) 22(.7) 23(.91) JIS K 21(.27) 17(6.69) 13(5.12) 71±.5(2.) 32(1.26) 23(.91) ANSI Class (7.5) 152.(6) 13(5.12) 71±.5(2.) 23.9(.9) 1.6(.6) 19.1(.75) ANSI Class (.25) 16.1(6.62) 13(5.12) 71±.5(2.) 2.5(1.12) 1.6(.6) 22.(.) JPI Class 15 19(7.) 152.(6) 13(5.12) 71±.5(2.) 2(.9) 1.6(.6) 19(.75) JPI Class 3 21(.27) 16.1(6.62) 13(5.12) 71±.5(2.) 2.5(1.12) 1.6(.6) 22(.7) DIN PN 1/16 2(7.7) 16(6.3) 13(5.12) 71±.5(2.) 2(.79) 1(.71) DIN PN 25/ 2(7.7) 16(6.3) 13(5.12) 71±.5(2.) 2(.9) 1(.71) * In case where process flange material is JIS S25C, value of f is. FE.EPS All Rights Reserved. Copyright 199, Yokogawa Electric Corporation GS 1C22J3-E Mar. 23, 26-

14 1 Terminal Configuration Terminal Wiring + SUPPLY Power supply and output terminal CHECK + External indicator(ammeter) terminal *1 Communication Terminals(BT2 etc.) Connection hook SUPPLY CHECK CHECK METER Connection hook *1 Ground terminal *1: When using an external indicator or a check meter, the internal resistance must be 1 or less. Not available for Fieldbus communication(output signal code F). F5E.EPS < Ordering Information > Specify the following when ordering 1. Model, suffix codes, and optional codes 2. Calibration range and units: 1) Calibration range can be specified with range value specifications up to 5 digits (excluding any decimal point) for low or high range limits within the range of -32 to 32. 2) Specify only one unit from the table Settings when shipped. 3. Select normal or reverse for operation mode Note: If not specified, the instrument is shipped in normal operation mode.. Display scale and units (for transmitters equipped with integral indicator only) Specify either to 1 % or engineering unit scale and Range and Unit for engineering units scale : Scale range can be specified with range limit specifications up to 5 digits (excluding any decimal point) for low or high range limits within the range of to Tag Number (if required) 6. Process fluid temperature for zero compensation (if required) < Related Instruments > Power Distributor: Refer to GS 1BT1-2E or GS 1BT2-2E BRAIN TERMINAL: Refer to GS 1CA11-E < Safety Barrier for TIIS Intrinsically Safe Type > Supplier Type Model MTL36B MTL MTL1B Isolator KFD2-STC3-Ex 1 P+F KFD2-STV3-Ex 1-1, 2, 3 T1E.EPS Note: Requirements of capacitance and inductance for cable wiring. Cw Co 11[nF] Lw Lo 73[µH] (Co: Max. external capacitance) (Lo: Max. external inductance) < Reference > 1. JIS SUS316L stainless steel; Equivalent to AISI 316L. 2. JIS SUS316 stainless steel; Equivalent to AISI JIS SUS3 stainless steel; Equivalent to AISI 3.. JIS S25C carbon steel; Equivalent to AISI JIS SECC; Carbon steel. 6. Teflon; Trademark of E.I. dupont de Nemours & Co. 7. JIS SCM35 chrome molybdenum steel; Equivalent to AISI JIS SUS63 stainless steel; Equivalent to ASTM Hastelloy; Trademark of Haynes International Inc. 1. JIS SCS1A stainless steel; Equivalent to JIS SUS316 cast stainless steel or ASTM CF-M. 11. HART; Trademark of the HART Communication Foundation. 12. FOUNDATION; Trademark of Fieldbus Foundation. 13. Other company names and product names used in this material are registered trademarks or trademarks of their respective owners. All Rights Reserved. Copyright 199, Yokogawa Electric Corporation Subject to change without notice. GS 1C22J3-E Mar. 23, 26-

General Specifications

General Specifications General Specifications GS 1C22H1-EN EJA11W, EJA11N and EJA11Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2] Diaphragm seals are used to prevent process medium form entering directly into

More information

General Specifications

General Specifications General Specifications Model EJA440A Gauge Pressure Transmitter GS 01C21E02-00E The high performance gauge transmitter model EJA440A can be used to measure liquid, gas, or steam. It outputs a 4 to 20 ma

More information

General Specifications

General Specifications General Specifications Model EJA120A Differential Pressure Transmitter GS 01C21B03-00E The high performance draft range differential transmitter model EJA120A outputs a 4 to 20 ma DC signal corresponding

More information

General Specifications

General Specifications General Specifications GS 1C25J3-1E EJX3A Diaphragm Sealed Gauge Pressure Transmitter Diaphragm seal is used to prevent process medium form entering directly into the pressure-sensing assembly of the pressure

More information

General Specifications

General Specifications General Specifications GS 01C25F01-01E EJX510A and EJX530A Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal

More information

General Specifications

General Specifications General Specifications GS 01C25J03-01EN EJX438A Diaphragm Sealed Gauge Pressure Transmitter [Style: S2] Diaphragm seal is used to prevent process medium form entering directly into the -sensing assembly

More information

General Specifications

General Specifications General Specifications GS 01C25J03-01EN EJX438A Diaphragm Sealed Gauge Pressure Transmitter [Style: S2] Diaphragm seal is used to prevent process medium form entering directly into the -sensing assembly

More information

General Specifications

General Specifications General Specifications GS 01C25F01-01E EJX510A and EJX530A Absolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single

More information

General Specifications

General Specifications General Specifications odel EJA130A Differential Pressure Transmitter GS 01C21B04-00E The high performance differential transmitter model EJA130A can be used to measure liquid, gas, or steam flow as well

More information

General Specifications

General Specifications General Specifications Model EJ430 Gauge Pressure Transmitter GS 01C21E01-00E The high performance gauge transmitter model EJ430 can be used to measure liquid, gas, or steam. It outputs a 4 to 20 m DC

More information

General Specifications

General Specifications General Specifications odel EJA110A Differential Pressure Transmitter GS 01C21B01-00E The high performance differential transmitter model EJA110A can be used to measure liquid, gas, or steam flow as well

More information

General Specifications

General Specifications General Specifications EJX110A Differential Pressure Transmitter GS 01C25B01-01E The high performance differential transmitter EJX110A features single crystal silicon resonant sensor and is suitable to

More information

General Specifications

General Specifications General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant

More information

General Specifications

General Specifications General Specifications EJX118A Diaphragm Sealed Differential Pressure Transmitter [Style: S2] Diaphragm seals are used to prevent process medium form entering directly into the -sensing assembly of the

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter GS 01C25E01-01E [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJA110A Differential Pressure Transmitter The high performance differential transmitter model EJA110A can be used to measure liquid, gas, or steam flow as well as liquid level, density

More information

General Specifications

General Specifications General Specifications GS 01C21F01-00E odel EJ510 and EJ530 bsolute and Gauge Pressure Transmitter [Style: S2] The absolute and gauge pressure transmitter model EJ510 and EJ530 can be used to measure liquid,

More information

General Specifications

General Specifications General Specifications GS 1C27H1-1EN EJX11B and EJX3B Diaphragm Sealed Differential Pressure and Gauge Pressure Transmitters Diaphragm seals are used to prevent process medium from entering directly into

More information

General Specifications

General Specifications General Specifications EJX510B and EJX530B Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitters EJX510B and EJX530B feature single crystal silicon resonant

More information

General Specifications

General Specifications General Specifications EJA120E Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJA120E features single crystal silicon resonant sensor and is suitable

More information

General Specifications

General Specifications General Specifications Model EJ430 Gauge Pressure Transmitter GS 01C21E01-00E The high performance gauge transmitter model EJ430 can be used to measure liquid, gas, or steam. It outputs a 4 to 20 m DC

More information

General Specifications

General Specifications General Specifications EJA440E Gauge Pressure Transmitter The high performance gauge transmitter EJA440E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam.

More information

General Specifications

General Specifications General Specifications EJX510A and EJX530A Absolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal silicon

More information

General Specifications

General Specifications General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant

More information

General Specifications

General Specifications General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to

More information

General Specifications

General Specifications General Specifications odel EJ120 Differential Pressure Transmitter The high performance draft range differential transmitter model EJ120 outputs a 4 to 20 m DC signal corresponding to the measured differential.

More information

General Specifications

General Specifications General Specifications EJA310E Absolute Pressure Transmitter The high performance absolute transmitter EJA310E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or

More information

General Specifications

General Specifications General Specifications EJX120A Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJX120A features single crystal silicon resonant sensor and is suitable

More information

General Specifications

General Specifications General Specifications EJA440E Gauge Pressure Transmitter The high performance gauge transmitter EJA440E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam.

More information

General Specifications

General Specifications General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications EJA120E Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJA120E features single crystal silicon resonant sensor and is suitable

More information

General Specifications

General Specifications General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJ510 and EJ530 bsolute and Gauge Pressure Transmitters [Style: S2] The absolute and gauge pressure transmitter model EJ510 and EJ530 can be used to measure liquid, gas, or steam

More information

General Specifications

General Specifications General Specifications EJA130E Differential Pressure Transmitter The high performance differential transmitter EJA130E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJX440A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX440A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications Model YTA110 Temperature Transmitter GS 01C0B01-00E [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs

More information

General Specifications

General Specifications General Specifications odel EJ310 bsolute Pressure Transmitter GS 01C21D01-00E The high performance gauge transmitter model EJ310 can be used to measure liquid, gas, or steam. It outputs a 4 to 20 m DC

More information

General Specifications

General Specifications General Specifications YTA0, YTA0 Temperature Transmitter [Style: S] The YTA0 and YTA0 are the highly accurate temperature transmitters that accept Thermocouple, RTD, ohms or DC milivolts inputs and converts

More information

General Specifications

General Specifications General Specifications EJA130E Differential Pressure Transmitter [Style: S2] The high performance differential transmitter EJA130E features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications odel EJ130 Differential Pressure Transmitter GS 01C21B04-00E The high performance differential transmitter model EJ130 can be used to measure liquid, gas, or steam flow as well as

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications EJA440E Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJA440E features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications EJA310E Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJA310E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJX120A Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJX120A features single crystal silicon resonant sensor and is suitable

More information

General Specifications

General Specifications General Specifications EJX110A Differential Pressure Transmitter [Style: S3] The high performance differential transmitter EJX110A features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJX510B and EJX530B Absolute and Gauge Pressure Transmitters The high performance absolute and gauge pressure transmitters EJX510B and EJX530B feature single crystal silicon resonant

More information

General Specifications

General Specifications General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

General Specifications

General Specifications General Specifications EJX130A Differential Pressure Transmitter [Style: S2] The high performance differential transmitter EJX130A features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJX115A Low Flow Transmitter [Style: S1] The low flow transmitter EJX115A is a differential transmitter assembled with an integral orifice and excellent for very low flow measurement.

More information

General Specifications

General Specifications General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,

More information

General Specifications

General Specifications General Specifications EJA530E S-Series Cherry Burrell I Line Sanitary Pressure Transmitter GS 530SCBS-01E The EJA530E S-Series sanitary pressure transmitters combine Yokogawa s EJA-E series in-line pressure

More information

DRS390 High stability, flange mounting

DRS390 High stability, flange mounting DRS 390 1 Monocrystalline silicon smart differential pressure transmitter DRS390 High stability, flange mounting Detailed Information Application the flow of gas, vapor and liquid measurement with device

More information

General Specifications

General Specifications General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,

More information

General Specifications

General Specifications General Specifications EJA110E Differential Pressure Transmitter [Style: S2] The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure

More information

General Specifications

General Specifications General Specifications EJX110A Differential Pressure Transmitter [Style: S3] The high performance differential transmitter EJX110A features single crystal silicon resonant sensor and is suitable to measure

More information

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS DRS 300 1 Monocrystalline silicon smart differential pressure transmitter DRS300 High stability Detailed Information application the flow of gas, vapor and liquid measurement with device (volume or mass

More information

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable

More information

AT9000 Advanced Transmitter Differential Pressure Transmitters

AT9000 Advanced Transmitter Differential Pressure Transmitters AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability.

More information

General Specifications

General Specifications General Specifications GS 01F06F01-01EN Model DY Vortex Flowmeter Model DYA Vortex Flow Converter FOUNDATION Fieldbus Communication Type General FOUNDATION Fieldbus is the digital communication line for

More information

DPharp Differential Pressure and Pressure Transmitters

DPharp Differential Pressure and Pressure Transmitters User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change

More information

General Specifications

General Specifications General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability.

More information

Absolute Pressure Transmitters

Absolute Pressure Transmitters No. SS2-GTX00A-0100 AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

General Specifications

General Specifications General Specifications GS 0121F01-02E odel EJ530/H Gauge Pressure Transmitter (High ccuracy Type) [Style: S2] The gauge pressure transmitter model EJ530/H can be used to measure liquid, gas, or steam pressure.

More information

General Specifications

General Specifications General Specifications EJX510 and EJX530 bsolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510 and EJX530 feature single crystal silicon

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO. : C3200-E05A Smart Pressure Transmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of smart transmitter brand series

More information

General Specifications

General Specifications General Specifications EJX610 and EJX630 bsolute and Gauge Pressure Transmitter The high performance gauge pressure transmitter EJX630 and absolute pressure transmitter EJX610 feature single crystal silicon

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model No. SS2-GTX00G-0600 AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance

More information

Differential Pressure Transmitters

Differential Pressure Transmitters AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable

More information

Instruction Manual. Model EJA438W and EJA438N Diaphragm Sealed Gauge Pressure Transmitters. [Style: S2] IM 1C22J1-01E 10th Edition

Instruction Manual. Model EJA438W and EJA438N Diaphragm Sealed Gauge Pressure Transmitters. [Style: S2] IM 1C22J1-01E 10th Edition Instruction Manual Model EJA43W and EJA43N Diaphragm Sealed Gauge Pressure Transmitters [Style: S2] Yokogawa Electric Corporation 10th Edition Blank Page CONTENTS CONTENTS 1. INTRODUCTION... 1-1 WARRANTY...

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

Absolute Pressure Transmitters

Absolute Pressure Transmitters AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable

More information

Field IT 2600T Series Pressure Transmitters

Field IT 2600T Series Pressure Transmitters Data Sheet Field IT 2600T Series Pressure Transmitters Model 364GS Gauge Model 364AS Absolute standard overload Best in class total performance long term stability of 0.25% for 10 years base accuracy of

More information

PTG series Smart Pressure Transmitter

PTG series Smart Pressure Transmitter No. SS2-PTG300-0100 PTG series Smart Pressure Transmitter Model PTG71 / PTG72 OVERVIEW The Smart Pressure Transmitter model PTG is a high- performance, highly reliable gauge pressure transmitter. Based

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) DATA SHEET FKH...5 The FCX AIII absolute pressure transmitter (Direct mount type) accurately measures absolute pressure and transmits proportional 4 to

More information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable of

More information

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable) Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically

More information

General Specifications

General Specifications General Specifications EJX510 and EJX530 bsolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510 and EJX530 feature single crystal silicon

More information

User s Manual Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2]

User s Manual Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2] User s Manual Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2] 18th Edition i Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure

More information

General Specifications

General Specifications General Specifications EJX510 and EJX530 bsolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510 and EJX530 feature single crystal silicon

More information

Instruction Manual. Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters. [Style: S2] IM 1C22H1-01E 10th Edition

Instruction Manual. Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters. [Style: S2] IM 1C22H1-01E 10th Edition Instruction Manual Model EJA11W, EJA11N and EJA11Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2] Yokogawa Electric Corporation 10th Edition Blank Page CONTENTS CONTENTS 1. INTRODUCTION...

More information

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions

More information

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A Doc. No. : C3100-E05A Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com Smart Pressure Transmitter APT3100 Standard Description

More information

General Specifications

General Specifications General Specifications EJX610 and EJX630 bsolute and Gauge Pressure Transmitter The high performance gauge pressure transmitter EJX630 and absolute pressure transmitter EJX610 feature single crystal silicon

More information