General Specifications
|
|
- Walter Benson
- 1 years ago
- Views:
Transcription
1 General Specifications EJX510A and EJX530A Absolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510A and EJX530A feature single crystal silicon resonant sensor and are suitable to measure liquid, gas, or steam pressure. EJX510A and EJX530A output a 4 to 20 ma DC signal corresponding to the measured pressure. It also features quick response, remote setup and monitoring via BRAIN or HART communications, diagnostics, and optional status output for pressure high/low alarm. The multisensing technology provides the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage. FOUNDATION Fieldbus protocol type is also available. All EJX series models in their standard configuration, with the exception of the Fieldbus type, are certified by TÜV as complying with SIL 2 for safety requirement. STANDARD SPECIFICATIONS Refer to GS 01C25T02-01EN for Fieldbus communication type marked with. SPAN AND RANGE LIMITS (For EJX510A, values are in absolute and lower range limits are 0.) Measurement Span/Range A B C D Span Range MPa 8 to 200 kpa 100 to 200 kpa psi (/D1) bar (/D3) kg/cm 2 (/D4) 1.16 to to to to 29 1 to 2 1 to 2 Span 0.04 to to to to 20 Range 0.1 to to to 20 1 to 20 Span 0.2 to to to to 100 Range 0.1 to to to to 100 Span 1 to to to to 500 Range 0.1 to to to to 500 PERFORMANCE SPECIFICATIONS Zero-based calibrated span, linear output, wetted parts material code S and silicone oil, unless otherwise mentioned. For Fieldbus communication type, use calibrated range instead of span in the following specifications. Specification Conformance EJX series ensures specification conformance to at least ±3σ. Reference Accuracy of Calibrated Span (includes the effects of terminal-based linearity, hysteresis, and repeatability) Measurement span A B C D Reference accuracy X URL (upper range limit) Span X ±0.1% of Span Span<X ±( URL/span)% of Span 20 kpa (2.9 psi) 200 kpa (29 psi) 0.2 MPa (29 psi) 2 MPa (290 psi) 1 MPa (145 psi) 5 MPa (720 psi) 10 MPa 50 MPa (1450 psi) (7200 psi) Ambient Temperature Effects per 28 C (50 F) Change ±(0.15% of Span 0.15% of URL) Stability (All normal operating condition) ±0.1% of URL per 1 year Power Supply Effects ±0.005 % per Volt (from 21.6 to 32 V DC, 350Ω) Vibration Effects Amplifier housing code 1 and 3: Less than 0.1% of URL when tested per the requirements of IEC field or pipeline with high vibration level (10-60 Hz, 0.21 mm peak to peak displacement/ Hz 3 g) Amplifier housing code 2: Less than ±0.1% of URL when tested per the requirements of IEC field with general application or pipeline with low vibration level (10-60 Hz 0.15mm peak to peak displacement / Hz 2g) Yokogawa Electric Corporation , Nakacho, Musashino-shi, Tokyo, Japan Tel.: Fax.: Copyright June th Edition Apr. 2012
2 Mounting Position Effects Rotation in diaphragm plane has no effect. Tilting up to 90 degree will cause zero shift up to 0.21 kpa (0.84 inh2o) which can be corrected by the zero adjustment. Response Time (All capsules) 90 msec When software damping is set to zero and including dead time of 45 msec (nominal) FUNCTIONAL SPECIFICATIONS Output Two wire 4 to 20 ma DC output with digital communications, linear or square root programmable. BRAIN or HART FSK protocol are superimposed on the 4 to 20 ma signal. Output range: 3.6 ma to 21.6 ma Output limits conforming to NAMUR NE43 can be pre-set by option code C2 or C3. Failure Alarm (Output signal code D and E) Output status at CPU failure and hardware error; Up-scale: 110%, 21.6 ma DC or more (standard) Down-scale: 5%, 3.2 ma DC or less Analog output status at process abnormality (Option code /DG6); The result of process abnormality detected by the advanced diagnostic function can be reflected to an analog alert status. The following three setting modes are available. Standard Option Code /C1 /C2 /C3 Mode Burnout Fall back Off 110%, 21.6mA or more -2.5%, 3.6mA or less -1.25%, 3.8mA or less 103.1%, 20.5mA or more Holds to a specified value within the Normal output output range from 3.6mA to 21.6mA Damping Time Constant (1st order) Amplifier s damping time constant is adjustable from 0.00 to sec by software and added to response time. Note: For BRAIN protocol type, when the software damping is set to less than 0.5 sec, communication may occasionally be unavailble during the operation, especially while output changes dynamically. The default setting of damping ensures stable communication. Update Period Pressure: 45 msec Zero Adjustment Limits Zero can be fully elevated or suppressed, within the lower and upper range limits of the capsule. External Zero Adjustment External zero is continuously adjustable with 0.01% incremental resolution of span. Re-range can be done locally using the digital indicator with rangesetting switch. Integral Indicator (LCD display, optional) 5-digit numerical display, 6-digit unit display and bar graph. The indicator is configurable to display one or up to three of the following variables periodically; pressure in %, scaled pressure, measured pressure. See also Factory Settings. Burst Pressure Limits A, B and C capsule: 30 MPa D capsule: 132 MPa Self Diagnostics CPU failure, hardware failure, configuration error, process alarm for pressure or capsule temperature. User-configurable process high/low alarm for pressure is also available, and its status can be output when optional status output is specified. Advanced Diagnostics (optional) Applicable for Output signal code E and F. Impulse line blockage detection The impulse line condition can be calculated and detected by extracting the fluctuation component from the static pressure signal. Heat trace monitoring The change of the process connection temperature calculated by using the two temperature sensors built in the EJX enables to detect the heat trace breakage or the abnormal temperature due to the failure. Signal Characterizer (Output signal code D and E) User-configurable 10-segment signal characterizer for 4 to 20 ma output. Status Output (optional, output signal code D and E) One transistor contact output (sink type) to output the status of user configurable high/low alarm for pressure. Rating: 10.5 to 30 V DC, 120 ma DC max. Note: A check meter cannot be connected when status output option (/AL) is specified. Refer to Wiring Example for Analog Output and Status Output. SIL Certification EJX series transmitters except Fieldbus communication type are certified by TÜV in compliance with the following standards; IEC 61508: 2000; Part1 to Part 7 Functional Safety of Electrical/electronic/ programmable electronic related systems; SIL 2 capability for single transmitter use, SIL 3 capability for dual transmitter use. 2
3 NORMAL OPERATING CONDITION (Optional features or approval codes may affect limits.) Ambient Temperature Limits 40 to 85 C ( 40 to 185 F) 30 to 80 C ( 22 to 176 F) with LCD display Process Temperature Limits 40 to 120 C ( 40 to 248 F) Ambient Humidity Limits 0 to 100% RH Maximum Over Pressure Pressure Capsule EJX510A EJX530A A and B C D 4 MPa abs (580 psia) 20 MPa abs (2900 psia) 75 MPa abs (10800 psia) Working Pressure Limits (Silicone oil) Maximum Pressure Limits 4 MPa (580 psig) 20 MPa (2900 psig) 75 MPa (10800 psig) Pressure Capsule EJX510A EJX530A A B C D 200 kpa abs (29 psia) 2 MPa abs (290 psia) 10 MPa abs (1450 psia) 50 MPa abs (7200 psia) Minimum Pressure Limit See graph below 200 kpa (29 psig) 2 MPa (290 psig) 10 MPa (1450 psig) 50 MPa (7200 psig) 100(14.5) Working pressure kpa abs (psia) 10(1.4) 2.7(0.38) 1(0.14) -40 (-40) Applicable range 0 (32) 40 (104) 80 (176) Process temperature C ( F) Figure 1-2. Working Pressure and Process Temperature [For EJX530A] 3 Atmospheric pressure 120 (248) F02E.ai Supply & Load Requirements (Output signal code D and E. Optional features or approval codes may affect electrical requirements.) With 24 V DC supply, up to a 550Ω load can be used. See graph below. 100(750) 10(75) 2.7(20) Working pressure kpa abs 1(7.5) (mmhg abs) 0.13(1) 0.1(0.75) Applicable range R (Ω) 600 External load resistance 250 R= E Digital Communication range BRAIN and HART Power supply voltage E (V DC) Figure 2. Relationship Between Power Supply Voltage and External Load Resistance F03E.ai 0.013(0.1) 0.01(0.075) -40 (-40) 0 (32) 40 (104) 80 (176) Process temperature C( F) Figure 1-1. Working Pressure and Process Temperature [For EJX510A] 120 (248) 85 (185) F01E.ai Supply Voltage 10.5 to 42 V DC for general use and flameproof type to 32 V DC for lightning protector (option code A) to 30 V DC for intrinsically safe, type n, nonincendive or non-sparking type. Minimum voltage limited at 16.6 V DC for digital communications, BRAIN and HART Load (Output signal code D and E) 0 to 1290Ω for operation 250 to 600Ω for digital communication
4 Communication Requirements (Approval codes may affect electrical requirements.) BRAIN Communication Distance Up to 2 km (1.25 miles) when using CEV polyethylene-insulated PVC-sheathed cables. Communication distance varies depending on type of cable used. Load Capacitance 0.22 µf or less Load Inductance 3.3 mh or less Input Impedance of communicating device 10 kω or more at 2.4 khz. EMC Conformity Standards, EN Class A, Table2 (For use in industrial locations) EN European Pressure Equipment Directive 97/23/EC Sound Engineering Practice (for all capsules) With option code /PE3 (for D capsule) < Related Instruments> Power Distributor: Refer to GS 01B04T01-02E or GS 01B04T02-02E BRAIN TERMINAL: Refer to GS 01C00A11-00E < Reference > 1. Hastelloy; Trademark of Haynes International Inc. 2. HART; Trademark of the HART Communication Foundation. 3. FOUNDATION Fieldbus; Tradmark of Fieldbus Foundation. Other company names and product names used in this material are registered trademarks or trademarks of their respective owners. 4 Category III, Module H, Type of Equipment: Pressure Accessory-Vessel, Type of Fluid: Liquid and Gas, Group of Fluid: 1 and 2 PHYSICAL SPECIFICATIONS Wetted Parts Materials Diaphragm, Process Connector Refer to MODEL AND SUFFIX CODES. Non-wetted Parts Materials Housing Low copper cast aluminum alloy with polyurethane, mint-green paint (Munsell 5.6BG 3.3/2.9 or its equivalent), or ASTM CF-8M Stainless Steel Degrees of Protection IP66/IP67, NEMA4X Pipe Polypropylene Cover O-rings Buna-N, fluoro-rubber (optional) Name plate and tag 316 SST Fill Fluid Silicone, Fluorinated oil (optional) Weight Capsule A, B and C: 1.2 kg (2.6 lb)* Capsule D: 1.4 kg (3.1 lb)* *: Without integral indicator and mounting bracket. Add 1.5 kg (3.3 lb) for Amplifier housing code 2. Connections Refer to MODEL AND SUFFIX CODES.
5 5 MODEL AND SUFFIX CODES Model Suffix Codes Description EJX510A EJX530A Absolute pressure transmitter Gauge pressure transmitter Output signal -D E F to 20 ma DC Output with digital communication (BRAIN protocol) 4 to 20 ma DC Output with digital communication (HART protocol) Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C25T02-01EN) Measurement span (capsule) A B C D to 200 kpa (1.16 to 29 psi) 0.04 to 2 MPa (5.8 to 290 psi) 0.2 to 10 MPa (29 to 1450 psi) 1 to 50 MPa (145 to 7200 psi) Wetted parts Process connection Diaphragm material *4 S L SST # Hastelloy C-276 *1# H Hastelloy C-276 *1# Hastelloy C-276 *1# Process connections /2 NPT female 1/2 NPT male G1/2 DIN male *2 M DIN male *2 N Always N Always 0 Amplifier housing Electrical connection A C D Integral indicator D E N Mounting bracket L N Optional Codes Cast aluminum alloy Cast aluminum alloy with corrosion resistance properties *7 ASTM CF-8M stainless steel *5 G1/2 female, one electrical connection without blind plugs 1/2 NPT female, two electrical connections without blind plugs M20 female, two electrical connections without blind plugs G1/2 female, two electrical connections with a blind plug *6 1/2 NPT female, two electrical connections with a blind plug *6 M20 female, two electrical connections with a blind plug *6 G1/2 female, two electrical connections and a 316 SST blind plug 1/2 NPT female, two electrical connections and a 316 SST blind plug M20 female, two electrical connections and a 316 SST blind plug Digital indicator Digital indicator with the range setting switch *3 (None) 316 SST 2-inch pipe mounting None / Optional specification The marks indicates the most typical selection for each specification. Example: EJX530A-DAS4N-012NN/. *1: Hastelloy C-276 or ASTM N *2: Not applicable for combination of capsule code D and wetted parts material code H. *3: Not applicable for output signal code F. *4: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150 C [302 F] or above). Contact Yokogawa for detailed information of the wetted parts material. *5: Not applicable for electrical connection code 0, 5, 7 or 9. *6: Material of a blind plug is aluminum alloy or 304 SST. *7: Not applicable for electrical connection code 0, 5, 7, 9 and A. Content rate of copper in the material is 0.03% or less and content rate of iron is 0.15% or less. The # marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.
6 6 OPTIONAL SPECIFICATIONS (For Explosion Protected type) Item Description Code Factory Mutual FM Explosionproof Approval *1 (FM) Applicable Standard: FM3600, FM3615, FM3810, ANSI/NEMA 250 Explosionproof for Class I, Division 1, Groups B, C and D, Dust-ignitionproof for Class II/III, Division 1, FF1 Groups E, F and G, in Hazardous locations, indoors and outdoors (NEMA 4X) FACTORY SEALED, CONDUIT SEAL NOT REQUIRED. Temperature class: T6, Amb. Temp.: 40 to 60 C (40 to 140 F) *3 FM Intrinsically safe Approval *1*2 Applicable Standard: FM3600, FM3610, FM3611, FM3810 Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G and Class III, Division 1, Class I, Zone 0, in Hazardous Locations, AEx ia IIC Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division. 2, FS1 Groups F & G, and Class III, Division 1, Class I, Zone 2, Group IIC, in Hazardous Locations Enclosure: NEMA 4X, Temp. Class: T4, Amb. Temp.: 60 to 60 C (75 to 140 F) *3 Intrinsically Safe Apparatus Parameters [Groups A, B, C, D, E, F and G] Vmax=30 V, Imax=200 ma, Pmax=1 W, Ci=6 nf, Li=0 µh [Groups C, D, E, F and G] Vmax=30 V, Imax=225 ma, Pmax=1 W, Ci=6 nf, Li=0 µh Combined FF1 and FS1 *1*2 FU1 ATEX ATEX Flameproof Approval *1 Applicable Standard: EN , EN , EN Certificate: KEMA 07ATEX0109 X II 2G, 2D Ex d IIC T6...T4 Gb, Ex tb IIIC T85 C Db IP6X Degree of protection: IP66 and IP67 KF22 Amb. Temp. (Tamb) for gas-proof : T4; 50 to 75 C (58 to 167 F), T5; 50 to 80 C (58 to 176 F), T6; 50 to 75 C (58 to 167 F) Max. process Temp. for gas-proof (Tp): T4; 120 C (248 F), T5; 100 C (212 F), T6; 85 C (185 F) Max. surface Temp. for dust-proof: T85 C (Tamb: 30 to 75 C, Tp: 85 C) *3 ATEX Intrinsically safe Approval *1*2 Applicable Standard: EN , EN , EN , EN Certificate: DEKRA 11ATEX0228 X II 1G, 2D Ex ia IIC T4 Ga, Ex ia IIIC T85 C T100 C T120 C Db Degree of protection: IP66 and IP67 KS21 Amb. Temp. (Tamb) for EPL Ga: 50 to 60 C (58 to 140 F) Maximum Process Temp. (Tp) for EPL Ga:120 C Electrical data: Ui=30 V, Ii=200 ma, Pi=0.9 W, Ci=27.6 nf, Li=0 μh Amb. Temp. for EPL Db: 30 to 60 C *3 Max. surface Temp. for EPL Db: T85 C (Tp: 80 C), T100 C (Tp: 100 C), T120 C (Tp: 120 C) Combined KF22, KS21 and Type n *1*2 Type n Applicable Standard: EN , EN KU22 II 3G Ex nl IIC T4 Gc, Amb. Temp.: 30 to 60 C (22 to 140 F) *3 Ui=30 V DC, Ci=10 nf, Li=0 mh
7 7 Canadian Standards Association (CSA) IECEx Scheme Item Description Code CSA Explosionproof Approval *1 Certificate: Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.0.5, C22.2 No.25, C22.2 No.30, C22.2 No.94, C22.2 No , C22.2 No , C22.2 No Explosion-proof for Class I, Groups B, C and D. Dustignition-proof for Class II/III, Groups E, F and G. When installed in Division 2, SEAL NOT REQUIRED Enclosure: TYPE 4X, Temp. Code: T6...T4 Ex d IIC T6...T4 Enclosure: IP66 and IP67 Max.Process Temp.: T4;120 C(248 F), T5;100 C(212 F), T6; 85 C(185 F) Amb.Temp.: 50 to 75 C(58 to 167 F) for T4, 50 to 80 C(58 to 176 F) for T5, 50 to 75 C(58 to 167 F) for T6 *3 Process Sealing Certification Dual Seal Certified by CSA to the requirement of ANSI/ISA No additional sealing required Primary seal failure annunciation: at the zero adjustment screw CSA Intrinsically safe Approval *1*2 Certificate: [For CSA C22.2] Applicable Standard: C22.2 No.0, C22.2 No.0.4, C22.2 No.25, C22.2 No.94, C22.2 No.154, C22.2 No.213, C22.2 No Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G, Class III, Division 1, Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division 2, Groups E, F & G, Class III, Division 1 Enclosure: Type 4X, Temp. Code: T4 Amb. Temp.: 50 to 60 C(58 to 140 F) *3 Electrical Parameters: [Intrinsically Safe] Vmax=30V, Imax=200mA, Pmax=0.9W, Ci=10nF, Li=0 [Nonincendive] Vmax=30V, Ci=10nF, Li=0 [For CSA E60079] Applicable Standard: CAN/CSA E , CAN/CSA E , CAN/CSA E , IEC 60529: Ex ia IIC T4, Ex nl IIC T4 Enclosure: IP66 and IP67 Amb. Temp.: 50 to 60 C(58 to 140 F) *3, Max. Process Temp.: 120 C(248 F) Electrical Parameters: [Ex ia] Ui=30V, Ii=200mA, Pi=0.9W, Ci=10nF, Li=0 [Ex nl] Ui=30V, Ci=10nF, Li=0 Process Sealing Certification Dual Seal Certified by CSA to the requirement of ANSI/ISA No additional sealing required Primary seal failure annunciation: at the zero adjustment screw Combined CF1 and CS1 *1*2 IECEx Flameproof Approval *1 Applicable Standard: IEC :2004, IEC :2003 Certificate: IECEx CSA Flameproof for Zone 1, Ex d IIC T6...T4 Enclosure: IP66 and IP67 Max.Process Temp.: T4;120 C(248 F), T5;100 C(212 F), T6; 85 C(185 F) Amb.Temp.: 50 to 75 C(58 to 167 F) for T4, 50 to 80 C(58 to 176 F) for T5, 50 to 75 C(58 to 167 F) for T6 *3 IECEx Intrinsically safe, type n and Flameproof Approval *1*2 Intrinsically safe and type n Applicable Standard: IEC :2000, IEC :1999, IEC :2001 Certificate: IECEx CSA Ex ia IIC T4, Ex nl IIC T4 Enclosure: IP66 and IP67 Amb. Temp.: 50 to 60 C(58 to 140 F) *3, Max. Process Temp.: 120 C(248 F) Electrical Parameters: [Ex ia] Ui=30V, Ii=200mA, Pi=0.9W, Ci=10nF, Li=0 [Ex nl] Ui=30V,Ci=10nF, Li=0 Flameproof Applicable Standard: IEC :2004, IEC :2003 Certificate: IECEx CSA Flameproof for Zone 1, Ex d IIC T6...T4 Enclosure: IP66 and IP67 Max.Process Temp.: T4;120 C(248 F), T5;100 C(212 F), T6; 85 C(185 F) Amb.Temp.: 50 to 75 C(58 to 167 F) for T4, 50 to 80 C(58 to 176 F) for T5, 50 to 75 C(58 to 167 F) for T6 *3 *1: Applicable for Electrical connection code 2, 4, 7, 9, C and D. *2: Not applicable for option code /AL. *3: Lower limit of ambient temperature is 15 C (5 F) when /HE is specified. CF1 CS1 CU1 SF2 SU2
8 8 OPTIONAL SPECIFICATIONS Item Description Code Painting Color change Amplifier cover only *14 P Amplifier cover and terminal cover, Munsell 7.5 R4/14 PR Coating change Anti-corrosion coating *1*14 X2 316 SST exterior parts 316 SST zero-adjustment screw and setscrews *16 HC Fluoro-rubber O-ring All O-rings of amplifier housing. Lower limit of ambient temperature: 15 C (5 F) HE Lightning protector Transmitter power supply voltage: 10.5 to 32 V DC ( 10.5 to 30 V DC for intrinsically safe type, 9 to 32 V DC for Fieldbus communication type.) Allowable current: Max A ( 1 40 µs ), Repeating 1000 A ( 1 40 µs ) 100 times Applicable Standards: IEC , IEC A Status output *2 Transistor output (sink type) Rating: 10.5 to 30 V DC, 120 ma DC (max) Low level: 0 to 2 V DC AL Oil-prohibited use Degrease cleansing treatment K1 Degrease cleansing treatment with fluorinated oilfilled capsule. Operating temperature 20 to 80 C ( 4 to 176 F) K2 Capsule fill fluid Flourinated oil filled in capsule Operating temperature 20 to 80 C ( 4 to 176 F) K3 Calibration units *3 P calibration (psi unit) D1 bar calibration (bar unit) (See Table for Span and Range Limits.) D3 M calibration (kgf/cm 2 unit) D4 Output limits and failure operation *4 Failure alarm down-scale : Output status at CPU failure and hardware error is 5%, 3.2mA DC or less. NAMUR NE43 Compliant Output signal limits: 3.8 ma to 20.5 ma Failure alarm down-scale: Output status at CPU failure and hardware error is 5%, 3.2 ma DC or less. Failure alarm up-scale: Output status at CPU failure and hardware error is 110%, 21.6 ma or more. Gold-plated diaphragm *13 Surface of isolating diaphragms are gold plated, effective for hydrogen permeation. A1 Wired tag plate 316 SST tag plate wired onto transmitter N4 Data configuration at factory *5 Software damping, Descriptor, Data configuration for HART communication type Message CA Data configuration for BRAIN communication type Software damping CB Advanced diagnostics *17 Multi-sensing process monitoring Impulse line blockage detection *18 DG6 Heat trace monitoring European Pressure Equipment Directive *15 PED 97/23/EC Category: III, Module: H, Type of Equipment: Pressure Accessory-Vessel, Type of Fluid: Liquid and Gas, Group of Fluid: 1 and 2 Material certificate *6 Process Connector M15 Pressure test/ Test Pressure: 200 kpa (29 psi) *7 T05 Leak test certificate *12 Test Pressure: 2 MPa (290 psi) *8 Nitrogen(N2) Gas or Water *11 T06 Test Pressure: 10 MPa (1450 psi) *9 Retention time: one minute T07 Test Pressure: 50 MPa (7200 psi) *10 T08 *1: Not applicable with color change option. *2: Check/External indicator terminals cannot be used when this option code is specified. Not applicable for output signal code F. *3: The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1, D3, and D4. *4: Applicable for output signal codes D and E. The hardware error indicates faulty amplifier or capsule. *5: Also see Ordering Information. *6: Material traceability certification, per EN B. *7: Applicable for capsule code A. *8: Applicable for capsule code B. *9: Applicable for capsule code C. *10: Applicable for capsule code D. *11: Pure nitrogen gas or pure water is used for oil-prohibited use (option codes K1 and K2). *12: The unit on the certificate is always kpa/mpa regardless of selection of option code D1, D3 and D4. *13: Applicable for wetted parts material code S. *14: Not applicable for amplifier housing code 2 and 3. *15: Applicable for measurement span code D. If compliance with category III is needed, specify this option code. *16: 316 or 316L SST. The specification is included in amplifier code 2. *17: Applicable only for output signal code -E. *18: The change of pressure fluctuation is monitored and then detects the impulse line blockage. See TI 01C25A31-01E for detailed technical information required for using this function. C1 C2 C3 PE3
9 DIMENSIONS Model EJX510A and EJX530A 9 Unit: mm (approx.inch) With process connections code 7 6 (0.24) 54 (2.13) Extenal indicator Conduit connection (optional) 159(6.26) 126(4.96) 95(3.74) 60(2.36)* 2 Integral indicator (optional) Conduit connection 165 (6.50) Zero adjustment Shrouding bolt (for flame-proof type) ø78(3.07) Ground terminal 110(4.33) 12 (0.47) 188(7.40) 39 (1.54) ø70 (2.76) 110(4.33) Electrical connection for code 5 and 9. Open to atmosphere* 1 Mounting bracket (optional) 12* 3 (0.47) 2-inch pipe (O.D mm) 129(5.08) *1: Only for EJX530A whose measurement span code is A, B, or C. *2: 58 mm (2.28 inch) for measurement span code D. *3: 11 mm (0.43 inch) for measurement span code D. With Process connections code (6.14) With Process connections code 8 and 9 5(0.20) 20(0.78) 172 (6.77) ø6 (0.23) F04E.ai Terminal Configuration Communication terminals (BT200 etc.) connection hook SUPPLY Check meter connection hook *4*5 CHECK or ALARM SUPPLY CHECK or ALARM Terminal Wiring SUPPLY CHECK or ALARM Power supply and output terminal External indicator (ammeter) terminal *4*5 or Status contact output terminal *5 (when /AL is specified) Ground terminal *4: When using an external indicator or check meter, the internal resistance must be 10Ω or less. A check meter or indicator cannot be connected when /AL option is specified. *5: Not available for fieldbus communication type. F05E.ai
10 10 Wiring Example for Analog Output and Status Output Connection Analog output EJX electrical terminal SUPPLY CHECK Description Distributor 24V DC 250Ω Analog and status output (when /AL is specified) If shield cable is not used, communication is not possible. EJX electrical terminal SUPPLY ALARM Shielded cable 250Ω External power supply 30V DC, 120mA max Distributor 24V DC Magnetic valve Use two-wire separately shielded cables. AC power supply F08E.ai
11 11 < Ordering Information > Specify the following when ordering 1. Model, suffix codes, and option codes 2. Calibration range and units 1) Calibration range can be specified with range value specifications up to 5 digits (excluding any decimal point) for low or high range limits within the range of to When reverse range is designated, specify Lower Range Value (LRV) as greater than Upper Range Value (URV). 2) Specify only one unit from the table, Factory Settings when shipped. 3. Display scale and units (for transmitters equipped with integral indicator only) Specify either 0 to 100 % or engineering unit scale and Range and Unit for engineering units scale: Scale range can be specified with range limit specifications up to 5 digits (excluding any decimal point) for low or high range limits within the range of to The unit display consists of 6-digit, therefore, if the specified unit is longer than 7 characters excluding /, the first 6 characters will be displayed on the unit display. 4. Tag Number (if required) For BRAIN communication type, specify upto 16 letters. The specified letters will be written in the amplifier memory and engraved on the tag plate. For HART communication type, specify software tag (up to 8 letters) to be written on the amplifier memory and Tag number(up to 16 letters) to be engraved on the tag plate seperately. 5. Other factory configurations (if required) Specifying option code CA or CB will allow further configuration at factory. Following are configurable items and setting range. [/CA : For HART communication type] 1) Descriptor (up to 16 characters) 2) Message (up to 30 characters) 3) Software damping in second (0.00 to ) [/CB : For BRAIN communication type] 1) Software damping in second (0.00 to ) < Factory Setting > Tag number As specified in order Software damping * sec or as specified in order Calibration range lower range value As specified in order Calibration range upper range As specified in order value Calibration range units Display setting [EJX530A] Selected from mmh2o, mmh2o(68 F), mmaq *2, mmwg *2, mmhg, Pa, hpa *2, kpa, MPa, mbar, bar, gf/cm 2, kgf/cm 2, inh2o, inh2o(68 F), inhg, fth2o, fth2o(68 F) or psi. (Only one unit can be specified) [EJX510A] Torr, Pa abs, hpa abs *2, kpa abs, MPa abs, mbar abs, bar abs, kgf/cm 2 abs, mmh2o abs, mmh2o abs(68 F), mmhg abs, inh2o abs, inh2o abs(68 F), inhg abs, fth2o abs, fth2o abs(68 F), psia, atm. Designated value specified in order. (%, or user scaled value.) *1: To specify these items at factroy, /CA or /CB option is required. *2: Not available for HART protocol type. < Material Cross Reference > ASTM grade 316 grade 316L grade 304 JIS SUS316 SUS316L SUS304 Subject to change without notice.
General Specifications
General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant
General Specifications
General Specifications EJX310A Absolute Pressure Transmitter [Style: S2] The high performance absolute transmitter EJX310A features single crystal silicon resonant sensor and is suitable to measure liquid,
General Specifications
General Specifications EJA510E and EJA530E Absolute and Gauge Pressure Transmitter The high performance absolute and gauge pressure transmitter EJA510E and EJA530E feature single crystal silicon resonant
General Specifications
General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,
General Specifications
General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus
General Specifications
General Specifications EJX120A Differential Pressure Transmitter The high performance draft range differential pressure transmitter EJX120A features single crystal silicon resonant sensor and is suitable
General Specifications
General Specifications EJA130E Differential Pressure Transmitter The high performance differential transmitter EJA130E features single crystal silicon resonant sensor and is suitable to measure liquid,
General Specifications
General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,
General Specifications
General Specifications EJX110A Differential Pressure Transmitter GS 01C25B01-01E The high performance differential transmitter EJX110A features single crystal silicon resonant sensor and is suitable to
General Specifications
General Specifications EJX430A Gauge Pressure Transmitter [Style: S2] The high performance gauge transmitter EJX430A features single crystal silicon resonant sensor and is suitable to measure liquid, gas,
General Specifications
General Specifications EJA110E Differential Pressure Transmitter The high performance differential transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid,
General Specifications
General Specifications EJA530E S-Series Cherry Burrell I Line Sanitary Pressure Transmitter GS 530SCBS-01E The EJA530E S-Series sanitary pressure transmitters combine Yokogawa s EJA-E series in-line pressure
General Specifications
General Specifications Model EJA120A Differential Pressure Transmitter GS 01C21B03-00E The high performance draft range differential transmitter model EJA120A outputs a 4 to 20 ma DC signal corresponding
General Specifications
General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to
General Specifications
General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC
General Specifications
General Specifications EJX510 and EJX530 bsolute and Gauge Pressure Transmitter [Style: S2] The high performance absolute and gauge pressure transmitter EJX510 and EJX530 feature single crystal silicon
General Specifications
General Specifications EJX610 and EJX630 bsolute and Gauge Pressure Transmitter The high performance gauge pressure transmitter EJX630 and absolute pressure transmitter EJX610 feature single crystal silicon
General Specifications
General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to
General Specifications
General Specifications YTA0, YTA0 Temperature Transmitter [Style: S] The YTA0 and YTA0 are the highly accurate temperature transmitters that accept Thermocouple, RTD, ohms or DC milivolts inputs and converts
General Specifications
General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC
General Specifications
General Specifications EJX910A Multivariable Transmitter [Style: S2] The high performance EJX910A multivariable transmitter features multi-sensing technology with a single-crystal silicon resonant sensor
General Specifications
General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC
General Specifications
General Specifications odel EJA110A Differential Pressure Transmitter GS 01C21B01-00E The high performance differential transmitter model EJA110A can be used to measure liquid, gas, or steam flow as well
Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS
Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process
AT9000 Advanced Transmitter Gauge Pressure Transmitters
AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable
AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model
No. SS2-GTX00G-0600 AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance
General Specifications
General Specifications odel EJ120 Differential Pressure Transmitter The high performance draft range differential transmitter model EJ120 outputs a 4 to 20 m DC signal corresponding to the measured differential.
AT9000 Advanced Transmitter Gauge Pressure Transmitters
AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability. Capable
General Specifications
General Specifications Model EJ430 Gauge Pressure Transmitter GS 01C21E01-00E The high performance gauge transmitter model EJ430 can be used to measure liquid, gas, or steam. It outputs a 4 to 20 m DC
MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With
Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE
Smart Pressure Transmitter
DOC. NO. : C3200-E05A Smart Pressure Transmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of smart transmitter brand series
PAD - Heavy Duty Differential Pressure Trasmitter
Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:
IP26 Series Current to Pneumatic Converter
Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear
Differential Pressure Transmitters
AT9000 Advanced Transmitter Differential Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable
Absolute Pressure Transmitters
AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable
Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11
Electronic pressure measurement Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11 WIKA data sheet PE 81.27 for further approvals see page
General Specifications
General Specifications YFGW510 Field Wireless Access Point GS 01W02E01-01EN GENERAL This General Specification(GS) describes the hardware specifications for Field Wireless Management Station and specifications
User s Manual Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A
User s Manual Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A 12th Edition i Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A
General Specifications
General Specifications YFGW510 Field Wireless Access Point GS 01W02E01-01EN GENERAL This General Specification(GS) describes the hardware specifications for Field Wireless Access Point and specifications
AT9000 Advanced Transmitter Gauge Pressure Transmitters
AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and ecellent stability. Capable of
ABSOLUTE PRESSURE TRANSMITTER
ABSOLUTE PRESSURE TRANSMITTER DATA SHEET FKA...5 The FCX -AIII absolute pressure transmitter accurately measures absolute pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes
Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement
Doc. No. : C3100-E05A FM APPROVED Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of
Specifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span
PERFORMANCE SPECIFICATIONS Reference Accuracy (1) Specifications Total Performance is based on combined errors of reference accuracy, ambient temperature effect, and static pressure effect. This product
APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement
For Gauge And Absolute Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate
PTG series Smart Pressure Transmitter
No. SS2-PTG300-0100 PTG series Smart Pressure Transmitter Model PTG71 / PTG72 OVERVIEW The Smart Pressure Transmitter model PTG is a high- performance, highly reliable gauge pressure transmitter. Based
FUNCTIONAL SPECIFICATIONS
DATA SHEET The ProcessX differential pressure (flow) transmitter accurately measures differential pressure, liquid leel, gauge pressure or fl ow rate and transmits a proportional 4 to 20mA signal. The
Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
Pressure transmitter (Direct mount type) Caractéristique fonctionnelles FKP* { } {1.3} FKP* {0.
DT SHEET The ProcessX pressure transmitter accurately measures gauge pressure and transmits proportional 4 to 20m signal. The transmitter utilizes the unique micromachined capacitie silicon sensor with
SATRON VB Pressure Transmitter
SATRON VB pressure transmitter belongs to the series V transmitters. SATRON VB is userfriendly, through the ball valve mounted transmitter which is used for 04 kpa... 03 MPa ranges. The transmitter communicates
Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
Series Smart Pressure Transmitter
www.tek-trol.com TEK-BAR 3100 Series Smart Pressure Transmitter www.tek-trol.com 2 Introduction The Tek-Bar series of smart transmitters have excellent stability, high accuracy and include features that
Non-Submersible Industrial Pressure Transducer
Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316
TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples
A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e
A New Generation Of Pressure Transmitters -AII V5 ECNO : 610e A New Transmitter at the edge of Technology As a leader in the field of measurement, Fuji Electric has an installed base of more than 1 000
A New Generation of Pressure Transmitters
Fuji Electric Instrumentation & Control A New Generation of Transmitters ECNO : 610d A New addition to the FCX Family at the edge of Technology As a leader in the field of pressure measurement, Fuji Electric
Submersible pressure sensor For oils and fuels Model LF-1
Level measurement Submersible pressure sensor For oils and fuels Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems for oils and fuels Overfilling and dry-run
Field Wireless Access Point
Field Wireless Access Point R-Y510 Features Connects Cosasco Wireless devices and other ISA100 Wireless transmitters to a Field Wireless Management Station High-performance, compact industrial wireless
FKP...5. Pressure transmitter (direct mount type) DATA SHEET FEATURES. Functional specifications
DT SHEET The ProcessX pressure transmitter accurately measures gauge pressure and transmits proportional 4 to 20 m signal. The transmitter utilizes the unique micromachined capacitie silicon sensor with
MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400
Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in
FKH...5. Absolute pressure transmitter DATA SHEET FEATURES SPECIFICATIONS. Functional specifications
DT SHEET The ProcessX absolute pressure transmitter (direct mount type) accurately measures absolute pressure and transmits proportional 4 to 20m signal. The transmitter utilizes the unique micromachined
Isolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
Model 266GSH Gauge Model 266ASH Absolute. 2600T Series Pressure Transmitters Engineered solutions for all applications
Data sheet DS/266GSH/ASH-EN Model 266GSH Gauge Model 266ASH Absolute 2600T Series Pressure Transmitters Engineered solutions for all applications Base accuracy from 0.06 % of calibrated span Reliable sensing
LGP Design. Can be ordered separately see specification 34-ST-03-55
ST 3000 Smart Transmitter Series 900 Gauge Pressure Models STG944 0 to 500 psi 0 to 35 STG94L 0 to 500 psi 0 to 35 STG974 0 to 3000 psi 0 to 210 STG97L 0 to 3000 psi 0 to 210 STG98L 0 to 6000 psi 0 to
Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
SALES SERVICE +358 (0)
SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control
Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision K FEATURES 4 to 20
PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.
PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL www.unitorq.com UT-1000 Electro-Pneumatic Positioners Linear & Rotary Unmatched Stability in Tough Environments. UniTorq s advanced-control electro-pneumatic
Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE
EJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual. Contents 1. Introduction. 3. Installation. 5.
User s Manual EJX and EJA-E Series Differential Pressure and Pressure s Installation Manual Contents 1. Introduction 1.1 For Safe Use of Product...2 1.2 Warranty...3 1.3 ATEX Documentation...4 2. Handling
General Specifications
General Specifications GS 0121F01-02E odel EJ530/H Gauge Pressure Transmitter (High ccuracy Type) [Style: S2] The gauge pressure transmitter model EJ530/H can be used to measure liquid, gas, or steam pressure.
ThermoPLUS Smart Temperature Transmitter
No. SS2-TT110-0100 ThermoPLUS Smart Temperature Transmitter Model TT61/71 (Integral Sensor type) OVERVIEW The models TT61/71 Smart Transmitter are temperature transmitters for the model TT90 integral temperature
Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters
Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications
Digital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE
Model 266HSH Gauge Model 266NSH Absolute. Measurement made easy. Engineered solutions for all applications
Data Sheet DS/266HSH/NSH-EN Rev. I Model 266HSH Gauge Model 266NSH Absolute Measurement made easy Engineered solutions for all applications Base accuracy from 0.06 % of calibrated span (optional 0.04 %)
Strong monosilicon gauge pressure transmitter
Product introduction Description Strong monosilicon gauge pressure transmitter SMP858 monosilicon pressure transmitter is a high performance pressure transmitter with international leading technology meticulously
Fisher 646 Electro-Pneumatic Transducers
Product Bulletin D101374X012 646 Transducers Fisher 646 Electro-Pneumatic Transducers Fisher 646 electro-pneumatic transducers, shown in figure 1, use a patented converter module that converts a 4 to 20
Relative and absolute pressure transmitter type 528
Relative and absolute pressure transmitter type 528 The compact type 528 pressure transmitter is based upon the Huba Control developed and since over 20 years well proven ceramic technology. These transmitters
LGP Design. Can be ordered separately see specification 34-ST-03-55
ST 3000 Smart Transmitter Series 900 Gauge Pressure Models STG944 0 to 500 psi 0 to 35 STG94L 0 to 500 psi 0 to 35 STG974 0 to 3000 psi 0 to 210 STG97L 0 to 3000 psi 0 to 210 STG98L 0 to 6000 psi 0 to
Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version
Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications
Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications
High-quality pressure transmitter For general industrial applications Model S-20
Electronic pressure measurement High-quality pressure transmitter For general industrial applications Model S-20 WIKA data sheet PE 81.61 Applications Critical industrial applications Demanding applications
Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F
Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
General Specifications
General Specifications GS 01E20C01-01E AXFA11 Magnetic Flowmeter Converter for Remote Flowtube The AXFA11 magnetic flowmeter high grade converter is a sophisticated product with outstanding reliability
Flow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters
Data Sheet Brooks Industrial Brooks Digital Series Digital MFC's and MFM's Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters General Features:
Installation guide 873 SmartRadar Control Unit & Antenna Unit
Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl
SMART TEMPERATURE TRANSMITTERS. smar
SMART TEMPERATURE TRANSMITTERS FEATURES Single unit accepts signal from: - Standart RTDs and Thermocouples - Single ended or differential sensing - mv signals from radiation pyrometers, load cells, etc.
KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents
KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter
OPTIMASS 1000 Technical Datasheet
OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160
Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
Isolating Repeater Input Series 9163
> For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de
FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex
Data Sheet 10/-8.54 EN Level 0: Information FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Resistance thermometer (2,
Model 266DHH Differential flange mounted. Measurement made easy. Engineered solutions for all applications
Data Sheet DS/266DHH-EN Rev. F Model 266DHH Differential flange mounted Measurement made easy Engineered solutions for all applications Base accuracy from 0.06 % of calibrated span Reliable sensing system
PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications
Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A
Fisher 4200 Series Electronic Position Transmitters
Product Bulletin D200357012 4200 Series Transmitter Fisher 4200 Series Electronic Position Transmitters Fisher 4200 Series electronic position transmitters (figure 1 and 2) combine field-proven electronic
Process display RIA 261
Technical Information TI 083R/24/ae Process display RIA 261 Digital loop powered field display for 4 to 20 ma current loops Features and Benefits Loop powered display, no additional power supply cable
AT200 External Mount Magnetostrictive Level Transmitter
Data sheet DS/AT200-EN Rev. W AT200 External Mount Magnetostrictive Level Transmitter High accuracy liquid level and interface level detection K-TEK Level Products Measurement made easy Features Certified
VITO LT. Global Experience. Locally Applied. A dependable choice.
VITO LT A dependable choice. your accuracy requirements for tank inventory. Global Experience. Locally Applied. The VITO LT probe belongs to the VITO family for temperature and water bottom measurement.
ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models. Specification and Model Selection Guide. Introduction 34-ST /24/06
ST 3000 Smart Pressure Transmitter Series 900 Differential Pressure Models STD924 0 to 400 inh 0 to 1,000 mbar STD930 0 to 100 psi 0 to 7,000 mbar STD974 0 to 3000 psi 0 to 210,000 mbar Introduction 34-ST-03-65