DC Current Zero Control for Nulling. Out Jaw/Sensor Offset. SMT Application. Features & Specs DCV: 400/600V±1.0% ACV: 400/600V±1.

Size: px
Start display at page:

Download "DC Current Zero Control for Nulling. Out Jaw/Sensor Offset. SMT Application. Features & Specs DCV: 400/600V±1.0% ACV: 400/600V±1."

Transcription

1 AC/DC MINI Digital Clamp Meter MS 2102 DC Current Zero Control for Nulling Out Jaw/Sensor Offset SMT Application DISPLAY: Digital and Analog Display, 3999 Counts and 42 Segments Bargraph, Digit is 9mm High DCV: 400/600V±1.0% ACV: 400/600V±1.5% DCA: 40A/400A± 2.5% ACA: 40A/400A± 2.0% Max. Diameter for Conductor: Ф28mm RESISTANCE: 400Ω±1.0% DATA HOLD CONTINUITY TEST AUTO RANGE AND MANUAL RANGE POWER: AAA(1.5V)x2 SIZE: 194x72x35 mm WEIGHT: Approx. 210g (including battery) 1

2 Digital Multimeter M 3900 DCV: 200m/2/20/200/1000V±0.5% ACV: 200mV/± 1.2%, 2/20/200V±0.8%, 700V/± 1.2% DC Current: 2μA± 2.0%, 200μ/2m/20mA±0.8%, 200m/2A /± 1.2%, 10A±2% AC Current: 20μA± 3.0%, 200μ/2m/20mA±1.0%, 200m/2A /± 1.8%, 10A±3% RESISTANCE: 200/2k/20k/200k/2M Ω ±0.5%, 20M Ω±1.0%, CONTINUITY TEST: Built in buzzer with sound DIODE CHECK: Test Current 1.0mA, Test Voltage 2.8V hfe: 1~1000 POWER SOURCE: 6F22(9V) x 1 SIZE: 88 x 172 x 36mm WEIGHT: 340g (including battery) DISPLAY: 26 x 60 mm LCD 2

3 Digital Multimeter M 830BZ DCV: 200m/2/20/200V±0.5% : 600V±0.8% ACV: 200/600V± 1.2% DC Current: 2m/20mA± 1.0%, : 200mA±1.5% 10A±3.0% RESISTANCE: 200/2k/20k/200kΩ ±0.8%, 2MΩ±1.0%, CONTINUITY TEST: Built in buzzer with sound DIODE CHECK: Test current 0.8mA, Test voltage 3V hfe: 1~1000 Signal Generator: 50Hz square wave Power source: 6F22(9V) x 1 Size Weight: 70x126x24mm WEIGHT: 170g (including battery) DISPLAY: 15 x 46 mm LCD 3

4 AC Digital Clamp Meter MS 2001 The Clampmeter comes with a very rugged and accurate CT. The Instrument comes in easy to carry Plastic Box. Display: 1999 Counts DCV: 1000V± 1.0% ACV: 750V± 1.0% ACA: 20/200/1000A± 2.0% RESISTANCE: 200/2000 Ω±1.0% DIODE TEST CONTINUITY TEST DATA HOLD BACK LIGHT POWER: BATTERY 6F22 (9V) X 1 SIZE: 250x99x43 mm WEIGHT: Approx. 480g 4

5 AutoRange LCR Meter MS 5300 Designed to international safety standard IEC The over-molding rubber case protec ts the meter to be stronger The test data can be transfer red to PC through an full isolated optical RS232 / USB interface A tilt stand provides position flexibility for viewing and operating the meter SMT application RESISTANCE: 600/6k/60k/600k/6M Ω±1.0%, 60M Ω±1.5% CAPACITANCE: 6nF±2.0%, 60n/600n/6 Ω F±1.0%, 60 Ω /600Ω /6mF±1.5% INDUCTANCE: 600 Ω H±2.5%; 6m/60m/600mH±1.5%; 6H:<4H ±2.8% >4H ±5.0%; 60H:<40H±3.5% >40H Unspecified AUTORANGE AND MANUAL RANGE DATA HOLD MAX. /MIN. VALUE MEASUREMENT AUTO POWER OFF / DISABLE AUTO POWER OFF POWER: 6 (1.5V) (AAA Type) 5

6 3φ Digtal Power Clamp Meter MS φ Power Clamp Meter with RS232 / USB Interface Features: Power Measurement of 3-Phase 3-Wire, 3-Phase 4- Wire, Single-Phase mode V, A, W, VA, VAR, kwh, PF, Hz Measurement Double Display two parameters on each menu and store 28 groups of measurement parameter Measure total power value and five power parameters of each phase in 3-Phase measurement Mode respectively Autorange and TRMS Display With PC RS232 / USB interface and windows graphics software Display measurement time and select tested signal be power supply for the clamp at one time. The instrument can measurement for long time Large LCD Display, Multifunctional button control Specifications: Max Conductor size: Ф50mm AC Current (A) : 40/100/400/1000 A ±2% AC Voltage (V) : 100/300/600 V ±1.2% Active power (kw) : 4/10/40/100/600 kw ±3% Apparent Power (kva) : 4/10/40/100/600 kva ±3% Power Factor (PF) : 0.3 cap to 0.3 ind ±0/02 Reactive power (KVAR) : 4/10/40/100/600 KVAR ±4% Active Energy (kwh) : 10/100/1000/10000 kwh ±3% Frequency (Hz) : 20Hz ~ 1000Hz 0.5% Display : 4 Digit LCD 9999 Power Supply 4X1.5V AA Operating Temperature 0ºC ~ 40ºC Dimensions : 300mmX103mmX51mm Weight : Approx. 500g 7

7 3φ Digtal Power Clamp Meter MS φ Power Clamp Meter with RS232 / USB Interface Features: Power Measurement of 3-Phase 3-Wire, 3-Phase 4- Wire, Single-Phase mode V, A, W, VA, VAR, kwh, PF, Hz Measurement Double Display two parameters on each menu and store 28 groups of measurement parameter Measure total power value and five power parameters of each phase in 3-Phase measurement Mode respectively Autorange and TRMS Display With PC RS232 / USB interface and windows graphics software Display measurement time and select tested signal be power supply for the clamp at one time. The instrument can measurement for long time Large LCD Display, Multifunctional button control Specifications: Max Conductor size: Ф50mm AC Current (A) : 40/100/400/1000 A ±2% AC Voltage (V) : 100/300/600 V ±1.2% Active power (kw) : 4/10/40/100/600 kw ±3% Apparent Power (kva) : 4/10/40/100/600 kva ±3% Power Factor (PF) : 0.3 cap to 0.3 ind ±0/02 Reactive power (KVAR) : 4/10/40/100/600 KVAR ±4% Active Energy (kwh) : 10/100/1000/10000 kwh ±3% Frequency (Hz) : 20Hz ~ 1000Hz 0.5% Display : 4 Digit LCD 9999 Power Supply 4X1.5V AA Operating Temperature 0ºC ~ 40ºC Dimensions : 300mmX103mmX51mm Weight : Approx. 500g 8

8 Harmonic Power Clamp Meter MS 2208 Features: Measuring power, voltage, current, peak value, phase, frequency, power factor, phase angle, and reaction factor, etc. of single-/three-phase circuit; automatic phase sequence testing is possible for 3- phase measurement. True effective value measurement: accurate measurement is possible even with serious distortion in current waveform. Low-consumption high-speed single-chip microprocessor is employed and sophisticated algorithm is applied, as a result, results can be obtained rapidly and precisely, and up to 20 harmonics and distortion value thereof can be measured. Current clamp size 26mm Conform to the IEC Standard CAT. 600V Power supply: 1.5V AAA Battery 3 Dimensions: 208mm 78mm 35mm Weight: about 350 g (with battery) Specifications: Function Range Accuracy AC Voltage(TRMS) 10V~600V (1.0%+5) AC Current(TRMS) Single-phase active power (Min. test current: 10mA; Min. test voltage: 10V) 2mA-3999mA 4A-200A 0.1W-120KW Capacitive (2%+5) (2%+5) (3%+5) (0.02+2) 9

9 Power factor Passive power Inductive 0.1W-120KW 30Hz 1kHz (0.02+2) (3%+5) (0.5%+1) Frequency Harmonic test Harmonic number: 1 Harmonic number: 2-6 (3.0%+10) (3.5%+10) (4.5%+10) Harmonic number :7-8 Harmonic number :9-10 (5.0%+10) (7%+10) (10%+10) Harmonic number :11-15 Harmonic number:

10 Digital Thermometers MS 6500 Features: Display: 1999 Counts, digits is 13mm High Input: K Type Thermocouples Data Hold Power: 6F22(9V)x1 Size: 125.5x72x27mm Weight: Approx. 145g (including battery) Resolution: 1ºC, 1ºF Centigrade: -50~-40ºC±6ºC, -39~-20ºC±5ºC, -19~0ºC±3ºC, 0~500ºC±0.75%, 501~750ºC±1% Fahrenheit: -58~-4F±7ºF, -3~32ºF±4ºF, 32~932ºF±2.0%, 933~1382ºF±1% 11

11 Non-Contact Infrared Thermometers MS 6530A Automatic range Wide temperature measurement Double digital LCD display MAX, MIN, MAX-MIN, average value selectable Back light C / F display selection Single-Spot Laser Sighting Hold function Low batter y indication Auto power off Measurement range -20~850 C - 4 F~1562 F Emissirity 0.95 Field of view 12 : 1 Resolution 0.1 C Display Back light LCD display Laser power <1mW Battery 6F22 (9V ) Over range indication OL or - OL Auto power off 10 Seconds 12

12 Non-Contact Infrared Thermometers MS 6550B Optical Resolution (D:S) (50:1) Wide temperature measurement range Laser target pointer Readout is F & C selectable KTC/infrared thermometers selection Temperature Resolution: 0.1 C or 0.1 F LCD with double temperature display and 4 bits MAX(highest), MIN(lowest), DIF(difference), and average (average) temperature display Emissivity adjustable (0.10 to 1.00) High-temp. and low-temp. alarm. Data recording (record up to 100 group of data) Response time: 500 msec Laser power: Less than 1 milli watt Optical Response: 8µm to 14µm Working Voltage: 9V battery Dimensions: Length 140X56X90 Weight: 500g Function Specifications MS6550B Infrared thermometers Temperature Range -32 ~1650 C(-25 ~ 3000 F) >510 C ±1.5% of the reading 50 ~510 C ±(1.5% of the reading +1 C) 15 ~ 50 C ±(1.5% of the reading + 2 C) -32 ~15 C ±3 C repeat error < 0.5 % of the reading, K-type thermometers Temperature Range -40 ~1370 C ±(1.5% of the reading +1 C) 13

13 Digital Luxmeter MS 6610 Display : 1999 counts, digit is 13mm high Range: 0 ~ 2000Lux±5.0%, 2000 ~ 19990Lux±5.0%, ~ 50000Lux±5.0% Data hold Photo dectector : One silicon photo diode with filter Photo dectector lead length: 150cm (Approx.) Photo dec tec tor size: 83mm x 52mm x 20.5mm Power : 6F22 (9V ) x 1 Size: 125.5mm x 72mm x 27mm Weight: Approx. 180g (including battery) 14

14 Digital Sound Level Meter MS 6700 Features: LCD digital display, Analog bar indicator, wide dynamic range, Auto/Manual range, Fast/Slow response selectable, Max value hold function, A/C weighting selection, Date weighting selection, AC/DC auxilitary output, Backlight, Low power indication Specifications: Measurement range: 30db~130db Accuracy: ±2db Resolution: 0.1 db Display: 3 ½ digits Sample rate: 2 times/s Frequency range: 30Hz~8KHz Over range indication: UNDER or OVER Auxilitary output: AC Vrms at full range for each level, impedance 600Ω DC 10m V/DB, impedance 100Ω Battery voltage: 6x1.5VAAA 15

15 Analog Clamp Meter MS 7160 AC Voltage: 300/600V+ (5% full scale AC Current: 3/12/60/30OA±(5% full scale) Resistance: 2K/200 KQ ±(5% full arc Temperature: -20 to 1 50 C/0 to 300 F(5% full scale) Operating temperature: 0 C up to 40 C atrh< 80% Dimensions: 148x66x36 mm Weight: approx. 160 g incl.battery Power supply: lxl.5v, IEC LR03/AAA IEC61010,CATII 300V 16

16 Multi-Function Process Calibrator MS 7282 This series of process calibrator multimeter is designed with exact current, voltage calibrator function and digital multimeter function, it is used for detecting and debugging automatic control equipment in industry scene. Calibrator 0~22mA ±(0.1% + 5digit) 0~100mV.0~1V±(0.1% + 5digit) 10.00Hz~10.00kHz±5digit Multimeter 0~1000V 0~700V 0~400mA 0~400mA 0~MΩ 0~200.0 µ F 0~5.000MHz Display (LCD) Primary and secondary Display Independently power (24V 30mA) AutoRange Battery Ni-Mh(include charger) 17

17 53000 Counts Bench Digital Multimeter MS 8050 Specification: High End Bench Top, Dual Display Digital Multimeter with RS232 / USB Interface Features: counts measurement ACV(TRMS) /ACV+DCV/dBm and DCV measurements reach up to 1000V 0.01Ω resistance and 1µV voltage resolution Logic frequency /Linear freqency and ducy cycle measurement Max/Min/Max-Min value,relative value,average value measurement VFD display RS232 / USB interface Data hold Data storage function Overload protection Software calibrates automatically Diode and continuity Test ACV measurement freqency response reach up to 20KHz Insulation performance reaching 1000V CAT II Power: 220V/110V AC Size: 350mm X 250 mm X 100mm Weight: approx 2100g Function Range Accuracy DCV ACV DCV+ACV DC Current AC Current Resistance Capacitance 50mV/500mV/5V/50V/500V/1000V 50mV/500mV/5V/50V/500V/1000V 500µA/5mA/50mA/500mA/5A/10A 500µA/5mA/50mA/500mA/5A 10A 50nF/500nF/5µF/50µF/ ±0.03% ±0.5% ±0.15% ±0.75% ±1.5% ±0.1% ±0.5% Logic Freqency Linear Freqency Duty cycle 18

18 MultiRange Digital Multimeter MS 8200G Designed to International Safety Standard IEC CATII 1000V Preventing the Test Leads from connecting wrongly DCV: 200m/2/20/200V±0.5%, 1000V±0.8% ACV: 2/20/200V± 1.0%, 700±1.2% DC Current: 2m/20mA±1.0%, 200mA±1.5%, 10A±2.0% AC Current: 2m/20mA±1.2%, 200mA±2.0%, 10A±3.0% RESISTANCE: 200/2k/20k/200k/2M/20MΩ ±1.0% CAPACITANCE: 2n/20n/200n/2μ/20μF±4.0% TEMPERATURE: -20ºC ~1000 ºC±3.0% FREQUENCY: 20KHz±1.5% CONTINUITY TEST DIODE CHECK POWER: 6F22(9V) x 1 SIZE: 191 x 82 x 36 mm WEIGHT: 280g approx. (including battery) DATA HOLD BACK LIGHT DISPLAY: 1999 Counts, DIGIT is 28mm HIGH 20

19 AutoRange Digital Multimeter MS 8217 Specifications DC Voltage range : 0.1 mv-1000v DC Voltage accuracy: ± 0.5%+3digits) DC Current range: 0.1 u A-l OA DC Current accuracy: ± (1.5%+3digits AC Voltage range: 0. ImV-IOOOV AC Voltage accuracy: ± l.0% + 3digits) AC Voltage Freq. response: 40Hz- 500Hz AC Current range: 0.1 v- A-l OA AC Current accuracy: + l.5% + 3digits) AC Current Freq. response: 40Hz- 200Hz Resistance range: 0.1 Q -40M Q Resistance accuracy: ± 0.5% + 2digits) Capacitance range: 0.01 nf-1 OOF Capacitance accuracy: ± (3.0% + 5digits) Frequency/Duty cycle Range: lohzlookhz Frequency/DutyCycleAccuracy: ± 0. l%+3digits) 21

20 Temperature Range: -55 C-1000 C Temperature Accuracy: ± ( C) Features 4000 counts Diode test/buzzer Temperature Test Frequency/Duty Cycle Relative Measurement Data Hold Hold Auto Power Off Auto/Manual Ranging Double Molded Mechanical/Electronic Protection System Conform to IEC 1010 CAT II 1000V Convenient Fuse/Battery Change Design Battery Life up to 500 Hours Lifetime Warranty 22

21 AutoRange TRMS Digital Multimeter MS 8220R DESIGNED TO INTERNATIONAL SAFETY STANDARD IEC61010-I CAT III 1000V SECONDARY INJECTION MODULDING CASE SMT APPLICATION RS232 STANDARD INTERFACE DISPLAY: 5999 COUNTS. DIGIT IS 2mm HIGH DC VOLTAGE: 6/60/600V ±0.5%, 1000V±0.8% AC VOLTAGE: 6/60/600V ±0.8%, 700V±1.0% DC CURRENT: 600ụ/6000ụ/60m/600mA ±1.2%, 10A±1.5% AC CURRENT: 600ụ/6000ụ/60m/600mA ±1.5%, 10A±2.0% RESISTANCE: 600/6k/60k/600k/6MΩ±1.5% CAPACITANCE: 6nF ±1.8%, 60n/600n/6ụ F±1.0%,60ụ/600ụ/6mF±1.5% FREQUENCE: 6000/60k/600k/6M/60MHz±0.5% TEMPERATURE:-40 C-500 C2.0%,501 C~1000 C±2.9% DIODE TEST CONTINUITY TEST -40 F-932 F2.0%,933 F~1832 F±2.9% AUTORANGE AND MANUAL RANGE DATA HOLD MAX./MIN VALUE MEASUREMENT BACK LIGHT 23

22 MultiRange Digital Multimeter MS 8222H AUTO POWER OFF DATA HOLD BACK LIGHT DISPLAY 1999 COUNTS AND 40 SEGMENTS ANALOG BAR DC VOLTAGE: 200mV/2V/20V/200V ±0.5%, 1000V +0.8% AC VOLTAGE: 200mV/2V/20V/200V ± 1.0%, 700V ±1.2% DC CURRENT: 2mA/20mA ± 1.0%, 200mA ± 1.5%, 10A ±2.0% AC CURRENT: 2mA/20mA ± 1.2%, 200mA ±2.0%, 1 OA ±3.0% RESISTANCE: 200Q/2kQ/20kQ/200kQ/2M Q/20M Q ± 1.0% CAPACITANCE: 2nF/20nF/200nF/2u F/20P F ±4.0% INDUCTANCE: 2mH/20mH/200mH/2H/20H ±3.0% FREQUENCY: 20kHz ± 1.5% CONTINUITY TEST TTL LOGIC TEST TRANSISTOR hfe TEST DIODE TEST 25

23 Digital Multimeter MS 8233C Function Range MS8233C 1 DC Volatge 600V 2V/20V/200V/600V ± 0.5%rdg + 3dgt ± 0.8%rdg + 5dgt ± 1.2%rdg+5dgtJ AC Volatge 2V/20V/200V/600V ± 1.2%rdg+5dgtJ DC Current 2 00 u A/2 ma/20 m A/2 00 ma + [1.0%rdg + 3dgt 200uA/20rnA/200mA I0A + 3.0%rdg + 5dgt] Resistor 200Q/2K/20K V200KO./2M 3 ± 0.8%rdg + 20MO 4dgt Frequency 20KHz ContiniutyCheck V Diode Check V Temperature -20"Cto 1000'C ± 3%rdg + 3dgt] Features Display Battery test Data Hold Back Light Non-Contact Voltaqe Detection Weight Size V V V 23 7g 150mmX70mmX50mm 26

24 High End Digital Multimeter MS 8240D Function Range Accuracy DC Voltage 220mV ±(0.05% +3 ) 2.2/22/220/I000V ±(0.1% +3) AC Voltage 220mV/2.2V/22V/220V/700V 50Hz] ±(0.8% 220mV/2.2V/22V/220V/700V(2KHz) +4 ) +(2.5% +3 ) 220u/2200u/22m 220m/1 OA ±(!%+4 ) DC Current ±(1% +4 ) 220u/2200u/22m 220m/1 OA + 1.5% +3 ) AC Current ±(1.8% +3 J 220/2.2K/22K/220K +(0.8% 2.2M/22M/220MQ +2 ) Resistance +(]% +2 ) Capacitance 22n/220n/2.2u/22u/220u 2.2m/22mF/220mF ±(2.5% +3 ) ±(2.5% +3 ) Frequency 1 Hz ~220MHz ±(0.2% +3 ) Duty 196 to 99% ±( ) Temperature Continuity J Test Diode Test Counts AutoRange and Manual Range DATA HOLD function MAX/min value measurement Full Overload protection Relative measurement Back Light 28

25 MS 8260E Conform to the lec6101o-l Standard CAT.III 1000V CAT. IV 600V Non-contact voltage detect Full Overload Protection Low Battery indication Function characters indication Auto Power Off Data Hold Back Light 30

26 MS 8260G Conform to the IEC Standard CAT.III 1000V CAT. IV 600V Non-contact voltage detect Full OverLoad Protection Low Battery indication Auto Range &Manual Range Rel Function Max/Min Funcrinn MS8260G) Auto Power Off Data Hold Back Light 31

27 MS 8264 Specifications DC Voltage: 200m/2V/20 V/200V/I000V ±0.5% AC Voltage: 200m/2V/20 V/200 V/750V ±0.8% DC Current: 2 ma 20mA/200mA i OA ±1.0% ±2.0% AC Current: 2mA/200mA ±1.0% 1 OA ±3.0% Resistance: 200/2K/20K/200K/2M 3/20MQ ±0.8% 200MQ ±5.0% Capacitance: 2n/20n/200n/2w/20uF ±4.0% 20n/200n/2u/200uF Inductance: 20m H/200m H/2H/20H Frequency: 20KHz Features Back light: Diode test: Hfe test: Continuity checking with buzzer; Temperture: V V V V V 32

28 Smart SMD Tester MS 8910 Features: Display: 3000 counts LCD display. Auto Scanning & Auto Ranging function. Therefore, fully automatic detecting the chip type resistance, capacitance or diode measurement. The construction of tester is compact and small type. So it as portable Testing set. The test leads is special construction and fixed on the main body for convenience of user. Data HOLD function Low-Battery Indication Auto Power OFF. Operating temperature & Humidity: 0 ~ 40 (32 ~104 ) & < 80% RH Storage temperature & Humidity: -10 ~ 50 (14 ~ 122 ) & <70%RH Power supply: 3V Lithium Battery 1pcs. FUNC key is used to selecting any measurement mode. Dimension (L x W x H): 175 x 32 x 19mm 33

29 AC Digital Clamp Meter M 266F Economical Multirange ClampMeter with Frequency Measurement DCV: 2/20/200V±0.5%, 1000V±0.8% ACV: 200V±1.0%, 750V± 1.2% ACA: 200A± 2.5%, 1000A±3% RESISTANCE: 200 Ω/2k Ω /20k Ω /200k Ω /2M Ω ±1.0% FREQUENCY: 2kHz±2.0% DIODE TEST: Check forward or reverse CONTINUITY TEST DATA HOLD: Provided DISPLAY : 1999Counts LCD SIZE: 15 x 47 mm DIMENSION: 96 x 235 x 46 mm WEIGHT: 310g 34

30 Digital Multimeter M 92A DCV: 200m/2/20/200/1000V± (0.5%+3) ACV: 200m/2/20/200/1000V± (0.8%+5) DC CURRENT: 20/200uA/2/20/200mA/2/10A ± (1.0%+5) AC CURRENt: : 20/200uA/2/20/200mA/2/10A ± (1.8%+5) RESISTANCE: 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20M ± (0.8%+3) : 200 MΩ±5% CAPACITANCE: 2/20/200nF/2uF/20uF TEMPERATURE: -20ºC ~1000 ºC FREQUENCY: 20KHz DATA HOLD DIODE TEST hfe TEST CONTINUITY CHECKING WITH BUZZER DISPLAY: 1999 Counts AUTO POWER OFF LOW BATTERY INDICATION 35

31 Digital Multimeter M 92A(H) DCV: 200m/2/20/200/1000V± (0.5%+3) ACV: 200m/2/20/200/1000V± (0.8%+5) DC CURRENT: 20/200uA/2/20/200mA/2/10A ± (1.0%+5) AC CURRENt: : 20/200uA/2/20/200mA/2/10A ± (1.8%+5) RESISTANCE: 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20M ± (0.8%+3) : 200 MΩ±5% CAPACITANCE: 2/20/200nF/2uF/20uF TEMPERATURE: -20ºC ~1000 ºC FREQUENCY: 20KHz DATA HOLD DIODE TEST hfe TEST CONTINUITY CHECKING WITH BUZZER DISPLAY: 1999 Counts AUTO POWER OFF LOW BATTERY INDICATION 36

Current Clamp. 210

Current Clamp. 210 Our range of devices includes clamp meters for measuring current leaks, AC and DC current, voltage, power, resistance, continuity, capacitance or frequency. Some clamp meters have a clearly arranged display

More information

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com Model ST-9933 True RMS Autoranging Digital Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-8 Technical...4-5 Accuracy...5-8 Display Description...

More information

LAV21 RMS (-T), LAV3 RMS (-T), LAA3 RMS (-T) Multi Channel Volt/Amp Recorders

LAV21 RMS (-T), LAV3 RMS (-T), LAA3 RMS (-T) Multi Channel Volt/Amp Recorders LAV21 RMS (-T), LAV3 RMS (-T), LAA3 RMS (-T) Multi Channel Volt/Amp Recorders > Time sharing capabilities channels are recorded sequentially > Chart paper stores readings for future reference > Three selectable

More information

TESTING & MEASUREMENT

TESTING & MEASUREMENT www.greenlee.com TESTING & MEASUREMENT Safe. Accurate. Reliable. Expect nothing but the best from Greenlee electric test and measurement equipment. Backed by a limited lifetime warranty and designed to

More information

0.5% Accuracy Overload Fuse protection Test Clips/Direct insert jack for easy measurement TES Capacitance Meter

0.5% Accuracy Overload Fuse protection Test Clips/Direct insert jack for easy measurement TES Capacitance Meter TES-1500 Capacitance 0.5% Accuracy Overload Fuse protection Test Clips/Direct insert jack for easy measurement TES-2620 TRMS Multimeter TES-2700 TES-2712 LCR Multimeter 3-3/4 Digital LCD with bar-graph

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1. DIGITAL MULTIMETERS Model M-1700 Model M-2775 Frequency to 20MHz Diode and Transistor Test AC/DC Current to 10A Three Way Overload Protection Extra Large 1 display test Data Hold Frequency to 20MHz Transistor

More information

Agilent 970-Series Handheld Multimeters Data Sheet

Agilent 970-Series Handheld Multimeters Data Sheet Agilent 970-Series Handheld Multimeters Data Sheet Benchtop features and performance with handheld convenience and price 3 1 /2and 4 1 /2 digits with dcv accuracy to 0.05% 1 khz to 100 khz frequency response

More information

Analog Technologies VC99. Multimeter FEATURES

Analog Technologies VC99. Multimeter FEATURES FEATURES LCD Display Max Display: 6000(3 6/7) Digits Automatic Polarity, Unit Symbol and 61 Section Analog Display Measurement Method: Double Integral A/D Conversion Sampling Rate: Approx.3 times/sec Over-Range

More information

GAMMA 12 DIGITAL MULTIMETER

GAMMA 12 DIGITAL MULTIMETER Gamma 12 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel

More information

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130 User s Guide MultiView Series Digital MultiMeters Models: MV110 MV120 MV130 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year

More information

APPA 300 Series. The Most User-Friendly High Performance Multimeter

APPA 300 Series. The Most User-Friendly High Performance Multimeter APPA 300 Series The Most User-Friendly High Performance Multimeter Throw Away the Manual... So Easy, So Simple Straight Forward... For basic application, simply to operate these keys... "LIGHT" "BAR" "DIGIT"

More information

ATK Clamp Meter

ATK Clamp Meter ATK-2209 Clamp Meter User s Manual Title CONTENTS Page I. SAFETY INFORMATION... 1 II. TECHNICAL SPECIFICATIONS... 2 2-1 Environment Conditions... 2 2-2 Maintenance... 2 2-3 Features... 2 2-4 General Specifications...

More information

Data sheet IDM 99III Digital Multimeter

Data sheet IDM 99III Digital Multimeter RS Stock No. 7575116 Data sheet IDM 99III Digital Multimeter Feature: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.08% basic DCV accuracy

More information

Table of Contents. Table of Contents Instrumentation Multimeter. Lucas Nülle GmbH Page 1/14

Table of Contents. Table of Contents Instrumentation Multimeter. Lucas Nülle GmbH Page 1/14 Table of Contents Table of Contents Instrumentation Multimeter 1 2 2 Lucas Nülle GmbH Page 1/14 www.lucas-nuelle.com Instrumentation Robust, educational and industrial measuring equipment for electrical

More information

NOTE: Fully read and understand this manual before using this Digital Multimeter.

NOTE: Fully read and understand this manual before using this Digital Multimeter. ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and

More information

Data sheet IDM 98III Digital Multimeter

Data sheet IDM 98III Digital Multimeter RS Stock No. 7575110 Data sheet IDM 98III Digital Multimeter FEATURE: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.1% basic DCV accuracy

More information

OPERATOR S INSTRUCTION MANUAL

OPERATOR S INSTRUCTION MANUAL OPERATOR S INSTRUCTION MANUAL AUTO-RANGE DUAL DISPLAY CONFORMED IEC1010 DIGITAL MULTIMETER CONTENTS PAGE SAFETY INFORMATION..... DESCRIPTION.. OPERATING INSTRUCTION.. SPECIFICATIONS.... ACCESSORIES. BATTERY

More information

Analog Digital Multimeter with Insulation Resistance Measurement

Analog Digital Multimeter with Insulation Resistance Measurement RISH MIT 30 Product Features: RISH MIT 30 is Analog Digital Multimeter with insulation resistance measurement, which measures VAC, VDC, VAC+DC,Frequency, ma DC, ma AC+DC,Resistance, continuity, Diode,

More information

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph ENGLISH Datasheet Stock No. 123-3249 RS PRO IDM 99III Digital Multimeter Feature: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.08% basic

More information

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER OWNER S MANUAL HH0308C AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER IMPORTANT! Read and understand this manual before using the tester. Failure to understand and comply with safety rules and operating

More information

Testing & Measurement

Testing & Measurement Greenlee is the leader in electrical testing and measurment and has been for more than fifteen years. Our innovative products are designed to withstand the rigorous tasks and harsh elements known to be

More information

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free User s Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting

More information

ENGLISH. Datasheet Stock No RS PRO IDM 98III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

ENGLISH. Datasheet Stock No RS PRO IDM 98III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph ENGLISH Datasheet Stock No. 123-3248 RS PRO IDM 98III Digital Multimeter Feature: 6000 count digital display with 62 segment bar graph Extra Large scale display and white backlit AC+DC True RMS 0.1% basic

More information

Testing & Measurement

Testing & Measurement Testing & Measurement Testing & Measurement Greenlee has been in the electrical testing and measurement fi eld for more than fi fteen years and has developed a wide range of electrical testers designed

More information

3 PHASE DIGITAL POWER CLAMP METER USERS MANUAL

3 PHASE DIGITAL POWER CLAMP METER USERS MANUAL PHASE DIGITAL POWER CLAMP METER USERS MANUAL CONTENTS Safety Precautions - - - - - - - - - - - - - - - - - - - - - - - - - - - Safety Information - - - - - - - - - - - - - - - - - - - - - - - - - - - Safety

More information

True RMS. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, REL, Capacitance Hz, Duty, ACV, ACA, DCV, DCA, Ohms

True RMS. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, REL, Capacitance Hz, Duty, ACV, ACA, DCV, DCA, Ohms True RMS AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, REL, Capacitance Hz, Duty, ACV, ACA, DCV, DCA, Ohms Caution Symbol Caution : * Risk of electric shock! Caution : * Do not apply the overload

More information

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

DL-91 DL-92 DL-94 DL-97

DL-91 DL-92 DL-94 DL-97 DL-91 DL-92 DL-94 DL-97 (Accuracy 0.5%) (Accuracy 0.3%) (Accuracy 0.1%) (Accuracy 0.06%) OUTLINE These four digital multimeters of the DL-90 Series have been designed to meet the diversifying needs users

More information

Extech Temperature & Humidity Dataloggers

Extech Temperature & Humidity Dataloggers Extech Temperature & Humidity Dataloggers Thermocouple Datalogger Chart Recorder RECORDERS / DATA LOGGERS Dual & differential temperature measurements Time stamped datalogging 7 thermocouple types Pushbutton

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

Technical Datasheet. Delta Power 1000A / 400A AC-DC

Technical Datasheet. Delta Power 1000A / 400A AC-DC Delta 1000A / 400A AC-DC Technical Datasheet Delta 1000A/ 400A AC-DC is specially designed for Measurement of AC-DC POWER and quality parameters. Up to 49th Individual Harmonics Non contact voltage detection.

More information

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at ASTROAI USER MANUAL DT132A 4000 Count Auto-Ranging Multimeter Thank you for purchasing the AstroAI DT132A 4000 Count Auto-Ranging Multimeter. It is a 3 ¾ digit, 3999 counts, auto-ranging digital multimeter.

More information

True RMS Digital Multimeter Model:

True RMS Digital Multimeter Model: True RMS Digital Multimeter Model: 72-7780 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTOMOTIVE MULTIMETER MODEL QM1444 the finger guards on the probes. Measuring voltage which exceeds the limits of the multimeter may damage the meter and expose the operator to a

More information

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement Data Sheet Analog Digital Multimeter with Insulation resistance www.rishabh.co.in Page 1 of 6 Version: J 28/12/2011 Application

More information

400Amp True RMS AC/DC Clamp Meter Model EX613

400Amp True RMS AC/DC Clamp Meter Model EX613 User's Guide 400Amp True RMS AC/DC Clamp Meter Model EX613 Introduction Congratulations on your purchase of this Extech EX613 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage,

More information

GAMMA 10 DIGITAL MULTIMETER

GAMMA 10 DIGITAL MULTIMETER Gamma 10 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel

More information

DVM1190 DIGITAL MULTIMETER

DVM1190 DIGITAL MULTIMETER DIGITAL MULTIMETER 1. Introduction Thank you for buying the. This digital multimeter has a large LCD, a data-hold function and a backlight. The device uses a very practical safety mechanism that keeps

More information

SUBJECT TO CHANGE WITHOUT NOTICE

SUBJECT TO CHANGE WITHOUT NOTICE www.sifamtinsley.co.uk DATASHEET Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters ijunior / JUNIOR Current Transformers Analogue Panel Meters

More information

INSTRUCTION MANUAL DIGITAL MULTIMETER

INSTRUCTION MANUAL DIGITAL MULTIMETER INSTRUCTION MANUAL DIGITAL MULTIMETER 600 OFF 600 20 2m 2 20m m m 2M 10A k 20k 2k O C NPN PNP hfe E B C E 10A DC 10A MAX UNFUSED MAX 600V COM V ma ma MAX FUSED CAT II 600V Thanks for buying our products,

More information

UT207A/208A/209A Operating Manual. Table of Contents

UT207A/208A/209A Operating Manual. Table of Contents Table of Contents Title Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Display Symbols Functional Buttons The Effectiveness

More information

HP-3310B 20M Colored Handheld Oscilloscope

HP-3310B 20M Colored Handheld Oscilloscope HP-3310B 20M Colored Handheld Oscilloscope 20M digital storage oscilloscope (DSO) Combination of a 4000 count auto-range True RMS DMM DMM functions include True RMS AC/DC voltage and current, resistance,

More information

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL Warnings and Safety symbols: Caution, refer to this manual before using the meter. Dangerous voltages. Meter is protected throughout by double insulation or

More information

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954 auto range, true rms ACA LEAKAGE TESTER Model : DL-9954 Your purchase of this ACA LEAKAGE TESTER marks a step forward for you into the field of precision measurement. Although this ACA LEAKAGE TESTER is

More information

MANUAL DE INSTRUÇÕES DO MULTÍMETRO DIGITAL MODELO MD-6456 Inglês

MANUAL DE INSTRUÇÕES DO MULTÍMETRO DIGITAL MODELO MD-6456 Inglês MANUAL DE INSTRUÇÕES DO MULTÍMETRO DIGITAL MODELO MD-6456 Inglês Novembro 2016 Leia atentamente as instruções contidas neste manual antes de iniciar o uso do multímetro Table of Contents The Statement...

More information

Simple measurement at the best price

Simple measurement at the best price Simple measurement at the best price n Multimeters n Clamp-on multimeters n Electrical safety testers n Testers n Environmental measurements n Laboratory instruments 01/2018 CONTENTS Multimeters page 3

More information

Clamp-on Testers. 300 Series and CL Series of Clamp-on Testers. Series

Clamp-on Testers. 300 Series and CL Series of Clamp-on Testers. Series Clampon Testers 300 Series and CL Series of Clampon Testers Series Leakage Clampon Tester with a sharp low pass filter function Leakage Clampon Tester capable of measuring from 1 ma AC Rich lineup for

More information

Pocket Size Digital Multimeter with USB Model: A & A

Pocket Size Digital Multimeter with USB Model: A & A Pocket Size Digital Multimeter with USB Model: 72-7730A & 72-7732A 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This instrument is

More information

DM-III MULTITEST Power Quality Recorder

DM-III MULTITEST Power Quality Recorder DM-III MULTITEST Power Quality Recorder Amprobe s full-featured Three-Phase Power Quality Recorders provide the essential functions and capabilities required to operate accurately and effectively in today

More information

The Meter Structure The Figure 2-1 shows the Meter structure.

The Meter Structure The Figure 2-1 shows the Meter structure. P/N:110401104496X The Meter Structure The Figure 2-1 shows the Meter structure. 1. USB Terminals 2. LCD Display 3. Functional Buttons 4. Rotary Switch 5. Power adaptor Input Terminals 6. 10A Input Terminal

More information

KMD-S04 Multímetro de bolsillo

KMD-S04 Multímetro de bolsillo www.grupotemper.com KMD-S04 Multímetro de bolsillo Table of Contents Title Page Overview ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 3 Unpacking Inspection ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 4 Safety Information

More information

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A TABLE OF CONTENTS TITLE PAGE Safety Information Safety Symbols... 1 Meter Description...

More information

BENCH MODEL MULTIMETER

BENCH MODEL MULTIMETER BENCH MODEL MULTIMETER Contents Contents... I Chapter 1... 1 Safety Standards... 1 Warning... 1 Warranty... 2 Chapter 2... 3 Introduction and Specifications... 3 Front Panel... 3 Rear Panel... 7 LCD Display

More information

AM

AM Us e rmanual Di gi t almul t i me t e r AM1109 EN 61010-1 CAT III 1000V Pollution Degree 2 Definition of Symbols: Caution: Refer to Accompanying Documents Caution: Risk of Electric Shock Double Insulation

More information

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User s Guide. 400A AC/DC Clamp Meter. Model MA220 User s Guide 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting the Extech MA200 AC/DC Clamp Meter. This meter measures AC/DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,

More information

Digital Multimeter Series

Digital Multimeter Series Digital Multimeter Series Series Series of 4.5-digit Handheld Multimeters Series of 3.5-digit Handheld Multimeters Series of 3.5-digit Handheld Multimeters of 3.5-digit Pocket Digital Multimeter Pocket

More information

Testing & Measurement. FEATURED Products. SF-780 Metal Locator. NEW-CM450 True RMS Clamp Meter. NEW AM-6 Analog Multimeter

Testing & Measurement. FEATURED Products. SF-780 Metal Locator. NEW-CM450 True RMS Clamp Meter. NEW AM-6 Analog Multimeter Greenlee is the leader in electrical testing and measurment and has been for more than fifteen years. Our innovative products are designed to withstand the rigorous tasks and harsh elements known to be

More information

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology INSTRUCTION MANUAL Auto-Ranging Digital Multimeter er True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE &

More information

Clamp-on Testers. 300 Series and CL Series of Clamp-on Testers. Series

Clamp-on Testers. 300 Series and CL Series of Clamp-on Testers. Series Clampon Testers 300 Series and CL Series of Clampon Testers Series NEW NEW Leakage Clampon Tester with a sharp low pass filter function Leakage Clampon Tester capable of measuring from 1 ma AC Rich lineup

More information

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC) User Manual Compact Autoranging Clamp Meters with NIST-Traceable Calibration Models 20250-55 (400 A AC), 20250-56 (400 A AC/DC) THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-55,-56 DS Clamp Meter

More information

Caution Symbol. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, Peak hold Bar graph display, Max/Min, REL, Cap.

Caution Symbol. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, Peak hold Bar graph display, Max/Min, REL, Cap. Caution Symbol AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, Peak hold Bar graph display, Max/Min, REL, Cap., Hz, RS232, Caution : * Risk of electric shock! Caution : * Do not apply the overload

More information

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623 User's Guide 400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623 Introduction Congratulations on your purchase of this Extech EX623 True RMS Clamp Meter. This meter measures AC Current, DC

More information

Family 400 meters Rel /04/2007

Family 400 meters Rel /04/2007 COMBI49 COMBI420 ISO40 SPEED48 Pag - 6. MAIN FEATURES OF FAMILY 400 METERS Help on line (available on each function) to support the user while connecting the instrument to the installation under measurement

More information

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE & FREQUENCY

More information

DM-III Multitest & DM-III Multitest F Power Quality Recorders

DM-III Multitest & DM-III Multitest F Power Quality Recorders DM-III Multitest & DM-III Multitest F Power Quality Recorders CAT 600V TRUE RMSz Amprobe s full-featured Three-Phase Power Quality Recorders provide the essential functions and capabilities required to

More information

METRAClip87 and 88 Clamp Multimeters

METRAClip87 and 88 Clamp Multimeters 3-349-795-03 1/7.14 Current and frequency measurement via clamp meter: METRAClip87: 1500 A AC TRMS and 1500 A DC METRAClip88: 2000 A AC TRMS and 3000 A DC Multimeter functions via connector sockets: V

More information

2000 A DCA/ACA CLAMP + DMM,

2000 A DCA/ACA CLAMP + DMM, 2000 A DCA/ACA CLAMP + DMM, true rms DCA/ACA CLAMP METER Model : CM-9930 Your purchase of this DCA/ACA CLAMP METER marks a step forward for you into the field of precision measurement. Although this CLAMP

More information

AMM-1130 USER`S MANUAL

AMM-1130 USER`S MANUAL AMM-1130 USER`S MANUAL www.tmatlantic.com Contents АМM-1130 Chapter 1 Safety Information Meter Safety Standards. 4 Warning. 4 Limited Guarantee and the Liability Range.. 5 Chapter 2 Introduction to the

More information

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL AC/DC DIGITAL CLAMP METER OPERATION MANUAL HYS005661 A0 ACCESSORIES 6. ACCESSORIES 1) Test Leads: Electric Ratings 1000V 10A 1 pair (set) 2) Operating Manual 1 copy 3) 1.5V AAA Battery 3 piece - - 55 -

More information

NEW PRODUC T BULLE TIN RADIO PARTS GROUP

NEW PRODUC T BULLE TIN RADIO PARTS GROUP CARBON MONOXIDE METER The CO110 carbon monoxide meter detects the presence of carbon monoxide (co) and measures concentrations between 1-1000 parts per million (ppm) CO110 47660001 The meter indicates

More information

S-11 S-11. Digital Multimeter Operating Instruction. Digital Multimeter Operating Instruction

S-11 S-11. Digital Multimeter Operating Instruction. Digital Multimeter Operating Instruction S-11 Digital Multimeter Operating Instruction S-11 Digital Multimeter Operating Instruction I. General introduction Welcome to use this product! This product is one kind of 3 6/7 portable multipurpose

More information

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV. MS8250A/B DIGITAL MULTIMETER OPERATION MANUAL AUTO DC AC REL hfe PCLINK % C F kmωkz nµmfav MS8250A DIGITAL MULTIMETER Auto Power Off RANGE REL HOLD FUNC NCV A ma OFF 10A A ma 10A FUSED 600V CAT IV COM

More information

G R E G E D WA R D S

G R E G E D WA R D S GREG EDWARDS Wireman Greenlee Category IV meters mean you can handle more power with more confidence. Independently certified to meet the highest safety standards Category IV compliance Greenlee s leading

More information

Testboy 65 Automotive-Multimeter

Testboy 65 Automotive-Multimeter Testboy 65 Automotive-Multimeter The Testboy 65 is particularly well suited for application in the automotive and workshop sector. Because, in addition to the standard multimeter functions, it also enables

More information

Model & MultiScope TM

Model & MultiScope TM Owner's Manual Model 381270 & 381275 MultiScope TM CAUTION: Read, understand and follow all Safety Rules and Operating Instructions in this manual before using this product. Test Equipment Depot - 800.517.8431-99

More information

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com USER'S MANUAL ACDC-100 TRMS ACDC-100 Versatile AC/DC Clamp-on Multimeter Series 1 1) SAFETY This manual contains information

More information

Digital Multi Meter OPERATING INSTRUCTION. Table of Contents

Digital Multi Meter OPERATING INSTRUCTION. Table of Contents Table of Contents Digital Multi Meter OPERATING INSTRUCTION 1. Introduction 2. Safety note 3. Explanation of Controls and Indicators 3-1. Product illustration 3-2. Functional push button 3-3. LCD display

More information

770E DIGITAL MULTIMETER OPERATOR S MANUAL

770E DIGITAL MULTIMETER OPERATOR S MANUAL 770E DIGITAL MULTIMETER OPERATOR S MANUAL TABLE OF CONTENTS 1.Overview... 1 2.Panel Layout...1/2 3. Safety information... 2 4. Specical cautions for operation.... 2 5.General specifications...2/3 6.Testing

More information

Digital Multimeters T820 DIY DMM T835 DIY DMM. T235H Electricians DMM. T1300H Electronic DMM. T48 Electronic DMM. T3601 Electricians DMM.

Digital Multimeters T820 DIY DMM T835 DIY DMM. T235H Electricians DMM. T1300H Electronic DMM. T48 Electronic DMM. T3601 Electricians DMM. T8 DIY DMM Low Cost Large LCD Display Continuity Diode 0m,2,,0,V 0,V 0µ,2m,m,0m,A 0,2K,K,0K,M ± 0.5% + Digit ± 1.2 % + Digit ± 1.5 % + 3 Digit ± 0.8 % + 3 Digit T835 DIY DMM Low Cost erature Continuity

More information

Clamp-on multimeters Multimeters Testers Electrical safety testers Environmental measurements Laboratory instruments 07/2018

Clamp-on multimeters Multimeters Testers Electrical safety testers Environmental measurements Laboratory instruments 07/2018 Simple measurement at the best price Clamp-on multimeters Multimeters Testers Electrical safety testers Environmental measurements Laboratory instruments 07/2018 Contents Clamp-on multimeters page 3 Multimeters

More information

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display 5 1/2 Digit DMM Series Enabling Dual Input and Display R6451A/6452A R6451A: General-Purpose Low-Price DMM with Standard Functions R6452A: Full-Functional DMM with Dual- Channel Input and Dual Display (Photo

More information

GAMMA 20 DIGITAL MULTIMETER

GAMMA 20 DIGITAL MULTIMETER Gamma 20 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel

More information

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE INSTRUCTION MANUAL Auto-Ranging Digital Multimeter MM400 DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE 600V 10A 40MΩ 2 GENERAL SPECIFICATIONS Klein Tools MM400 is an auto-ranging

More information

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30 Handleiding / Manual INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Digital Clamp Multimeter from its packing, you should

More information

Digital multimeter with CAT III 1000 V

Digital multimeter with CAT III 1000 V PCE-DM12 PCE-DM32 DM-9960 Digital multimeter with auto-ranging Digital multimeter with CAT III 1000 V Multimeter with Peak measurements and frequency up to 40 MHz This digital multimeter is a new device

More information

AC/DC CLAMP METER USER S MANUAL

AC/DC CLAMP METER USER S MANUAL AC/DC CLAMP METER USER S MANUAL CONTENTS PAGE SAFETY INFORMATION SYMBOL EXPLANATION SAFETY PRECAUTIONS 1 1 2 MAINTENANCE 3 GENERAL DESCRIPTION 4 PANEL DESCRIPTION 4 OPERATING INSTRUCTIONS... 7 SPECIFICATIONS

More information

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

User's Guide Extech EX Amp Clamp Meter with IR Thermometer User's Guide Extech EX810 1000 Amp Clamp Meter with IR Thermometer Patented Introduction Congratulations on your purchase of the Extech EX810 Clamp Meter. This meter measures AC/DC Voltage, AC Current,

More information

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION An ISO 9001:2008 Company 2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION SPECIAL FEATURES : 2000A AC Clamp-on + Full Multimeter ranges AC True RMS Voltage & Current functions Autocheck

More information

DIGITAL MULTIMETER AUTORANGING

DIGITAL MULTIMETER AUTORANGING MODEL: D03124 DIGITAL MULTIMETER AUTORANGING 1 CONTENTS Page Number Details 2 Introduction 2 What s Included 3 Important Safety Information 3 Symbol Guide 4 Overview 5 Buttons 5 Display Indicators 6 General

More information

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual DUAL DISPLAY DIGITAL MULTIMETER User s Manual MS8250D 1. Safety Information Warning Use caution and follow all safety guidelines to prevent electric shock or damage to the meter. Please ready carefully

More information

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL Contents I. General...- 1 - Ⅱ. Open-package Inspection...- 2 - III. Safety Considerations... - 3 - IV.Instrument Panel & Button Function Description...- 9 -

More information

VC835 DIGTAL MULTIMETER Operation Manual

VC835 DIGTAL MULTIMETER Operation Manual VC835 DIGTAL MULTIMETER Operation Manual CONTENTS GENERAL DESCRIPTION Safety Instructions FEATURES OPERATION MAINTENANCE TROUBLE SHOOTING 1. General Description This is a 3 1/2 digital multimeter with

More information

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology ENGLISH INSTRUCTION MANUAL 2000A Digital Clamp Meter True RMS Measurement Technology NON-CONTACT VOLTAGE TESTING INRUSH CURRENT LOW IMPEDANCE DATA HOLD RANGE HOLD AUDIBLE CONTINUITY DIODE TEST CAPACITANCE

More information

METRAClip85 and 86 Clamp Multimeters

METRAClip85 and 86 Clamp Multimeters 3-349-794-03 1/8.14 Current and frequency measurement via clamp meter: 600 A AC TRMS and 900 A DC (automatic or manual switching) Multimeter functions via connector sockets: V (AC TRMS and DC) up to 1000

More information

Extech Temperature & Humidity Dataloggers

Extech Temperature & Humidity Dataloggers Extech Temperature & Humidity Dataloggers Thermocouple Datalogger Chart Recorder RECORDERS / DATA LOGGERS Dual & differential temperature measurements Time stamped datalogging 7 thermocouple types Pushbutton

More information

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER with Temperature Probe Copyright 2007 Elenco Electronics, Inc. Contents 1. Safety Information 3,4 2. Safety Symbols 5 3. Front Plate

More information

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter DL6508 User's Guide 1500Amp True RMS AC/DC Clamp Meter Introduction Congratulations on your purchase of this DL6508 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage, Resistance,

More information

PC500 PC510 DIGITAL MULTIMETER INSTRUCTION MANUAL

PC500 PC510 DIGITAL MULTIMETER INSTRUCTION MANUAL PC500 PC510 DIGITAL MULTIMETER INSTRUCTION MANUAL [1] SAFETY PRECAUTIONS CONTENTS 1-1 Explanation of Warning Symbols 001 1-2 Warning Instruction for Safe Use 001 1-3 Overload protections 002 [2] APPLICATION

More information

DM-46 Instruction Manual

DM-46 Instruction Manual Auto Meter Products Inc. Test Equipment DM-46 Instruction Manual Automotive Multimeter and Inductive Amp Probe The DM-46 is the auto industry s answer to pocket portability in a 20 2650-1552-00 3/8/11

More information