Family 400 meters Rel /04/2007

Size: px
Start display at page:

Download "Family 400 meters Rel /04/2007"

Transcription

1 COMBI49 COMBI420 ISO40 SPEED48 Pag - 6. MAIN FEATURES OF FAMILY 400 METERS Help on line (available on each function) to support the user while connecting the instrument to the installation under measurement Each model permits the Start of measurements with remote probe (PR400 optional accessory) General menu to quickly selection of available test performed by meter (COMBI49 and COMBI420 models only)

2 COMBI49 COMBI420 ISO40 SPEED48 Pag 2-6. MODELS AND FEATURES Measurements ISO40 SPEED48 COMBI49 COMBI420 Continuity test on protective conductor with 200mA Insulation resistance VDC RCDs tripping time and current (general and selective, AC and A types) mA Contact voltage Ut Loop impedance P-N, P-P, P-PE Loop impedance P-N, P-P, P-PE with high resolution (0.mΩ) with IMP57 optional accessory Prospective short circuit current Global earth resistance Ra without RCDs tripping Phase sequence Leakage current (with HT96U optional accessory) AUTOMATIC test (Ra, RCD time, Insulation) directly on outlet ACTRMS voltage and current in Single phase system Active, reactive, apparent powers and power factor in Single phase system Harmonic analysis U, I, up to 49 th order and THD% Environmental parameters ( C, %HR, Lux, sound level) Using optional remote probe for activation of tests Contextual help at display Memory and PC interface 2. ELECTRICAL SPECIFICATIONS (*) Accuracy is indicated as ± (% rdgs + no. of dgt) at 23 C ± 5 C, con relative humidity <60%HR (*) Technical specification can be modified without notice Continuity test on protective conductors (COMBI49-COMBI420) Range (Ω) Resolution (Ω) Accuracy (*) Category of measure (*) after cable calibration which eliminates the cable resistance Test current: >200mA DC per R 5Ω (calibration included) current measurement resolution: ma Open leads voltage: 4 < V 0 < 24V RCDs tripping time (COMBI49-COMBI420) Range (ms) Resolution (ms) Accuracy Category of measure ½ I, I general 2 I 250 selective ±(2.0%rdg + 2 dgt) 50 general 5 I RCD 60 selective Nominal tripping current: RCD type: Phase-ground voltage: Frequency: Voltage contact limits: 0mA, 30mA, 00mA, 300mA, 500mA AC, A, general and selective 00V 265V 50Hz ± 0.5Hz, 60Hz ± 0.5Hz 25V or 50V

3 COMBI49 COMBI420 ISO40 SPEED48 Pag 3-6 RCDs tripping current (general, AC and A types) (COMBI49-COMBI420) RCD s type I Range I (ma) Resolution (ma) Accuracy Category of measure AC (0.5.4) I I 0mA 0. I A (0.5 2) I -0%, +5.0% I AC (0.5.4) I I > 0mA 0. I A (0.5 2) I Insulation resistance (DC voltage) (COMBI49-COMBI420) Test voltage (V) Range (MΩ) Resolution (MΩ) Accuracy Category of measure ±(5.0%rdg + 2dgt) ±(5.0%rdg + 2dgt) ±(5.0%rdg + 2dgt) ±(5.0%rdg + 2dgt) ±(5.0%rdg + 2dgt) Open leads voltage:. x nominal test voltage voltage measurement resolution:v Short circuit current: 500V 50, 00, 250, 000V Nominal current: 230kΩ, 500V; MΩ, 000V Protections: the instrument returns an error message while detecting an input voltage >30V Contact voltage Ut (COMBI49-COMBI420) Range (V) Resolution (V) Accuracy Category of measure 0 2Utlim 0. -0%, +(2.0%rdg + 2dgt) Utlim (Ul): 25V, 50V Loop impedance P-P, P-N, P-PE (COMBI49-COMBI420) Range (Ω) Resolution (Ω) (*) Accuracy Category of measure ±(5.0% rdg + 2 dgt) (*) 0.mΩ in mω range (with option accessory IMP57) Maximum peak current: 27V; 400V Test voltage: V (phase-neutral) / V (phase-phase); 50Hz ± 0.5Hz, 60Hz ± 0.5Hz

4 COMBI49 COMBI420 ISO40 SPEED48 Pag 4-6 Global Earth Resistance R A without tripping the RCD (COMBI49-COMBI420) Range (Ω) Resolution (Ω) Accuracy Category of measure ±(5.0%rdg +.0Ω) ±(5.0%rdg + 0dgt) 999 Test 265V: Test voltage: Utlim (Ul): 25V, 50V <5 ma V (phase-neutral); 50Hz ± 0.5Hz, 60Hz ± 0.5Hz Phase sequence with or 2 wires (COMBI49-COMBI420) Range (V) Results displayed Category of measure 23 correct phase sequence wrong phase sequence - phase coincidence The instrument detects the phase sequence by touching the hot wire. The detection is not performed on insulated cables. Frequency: 50Hz ± 0.5Hz, 60Hz ± 0.5Hz AC TRMS Voltage (voltmetric input) (COMBI420) Range (V) Frequency (Hz) Resolution (V) Accuracy Category of measure ±(.0%rdg + 2dgt) Crest factor:.4 Voltage indicated it s the Max TRMS value considered between any couple of inputs Frequency (voltmetric input and AUX input) (COMBI420) Range (Hz) Resolution (Hz) Accuracy Category of measure ± (2%rdg + 2dgt) Voltage range: 5V 460Vrms Voltage harmonics (voltmetric input) (COMBI420) Range Resolution (V) Accuracy 2nd 20th ± (0% rdg + 2 dgt) 0.% Vh 2st 49th ± (20% rdg + 2 dgt) Voltage range: 5V 460Vrms Fundamental frequency range : 47 63Hz AC TRMS Current (amperometric input) (COMBI420) Range (mv) Resolution (mv) Accuracy Category of measure ±(.0%rdg + 2dgt) Frequency range : 47Hz 63Hz Frequency (amperometric input) (COMBI420) Range (Hz) Resolution (Hz) Accuracy Category of measure ± (2%rdg + 2dgt) Voltage range: 5mV 200mVrms Current harmonics (amperometric input) (COMBI420) Range Resolution (V) Accuracy Category of measure 2a 20a 0.% Ih ± (2% lettura + 2 cifre) 2a 49a Frequency range: 47Hz 63Hz

5 COMBI49 COMBI420 ISO40 SPEED48 Pag 5-6 Current range: 0.00xCFS.2xCFS CFS = Clamp Full Scale Power (COMBI420) Measurement Range Power factor Accuracy 0,05CFS V AUX 0,CFS ±,5% rdg 0.V x 0.00 CFS 0,CFS V AUX CFS ±,0% rdg ACTIVE POWER 460.0V x.2 CFS 0,CFS V 0.8 ind, 0.8 cap AUX 0,2CFS ±,5% rdg 0,2CFS V AUX CFS ±,0% rdg 0,05CFS V AUX 0,CFS ± 2,5% rdg 0,CFS V AUX CFS ± 2,0% rdg 0.V x 0.00 CFS REACTIVE POWER 0,CFS V 0.5 ind, 0.5 cap AUX 0,2CFS ± 2,5% rdg 460.0V x.2 CFS 0,2CFS V AUX CFS ± 2,0% rdg 0.25 ind, 0.25 cap 0,2CFS V AUX CFS ± 7,0% rdg CFS = Clamp Full Scale V AUX = current value converted in voltage signal Power factor (cosϕ) (COMBI420) Range Resolution Accuracy ± 2 dgt Leakage current AC TRMS (amperometric input) (COMBI49-COMBI420) Range (mv) Resolution (mv) Accuracy Category of measure 200 ±(.0%rdg + 2dgt) Frequency range: 50Hz 60Hz

6 COMBI49 COMBI420 ISO40 SPEED48 Pag GENERAL SPECIFICATIONS MECHANICAL FEATURES Dimensions: Weight (batteries included): Protection degree: MEMORY AND SERIAL INTERFACE Each measurement can be stored Memory: PC communication port: DISPLAY: Features: 240 (L) x 60 (W) x 70 (D) mm about.2kg IP50 >600 locations optical / USB graphic LCD with backlight POWER SUPPLY: Batteries: 6x.5V type LR6, AA, AM3, MN 500 Battery life: > 600 measurements (without using the timer) ENVIRONMENTAL CONDITIONS: Reference temperature of calibration: 23 C ± 5 C Working temperature: 0 40 C Working humidity: < 80%HR Storage temperature (batteries not included): C Storage humidity: < 80%HR GENERAL REFERENCE STANDARDS: EMC: 89/336/EEC guideline amended with 93/68/EEC (IEC6326) LVD: 73/23/CEE guideline (IEC600) Product guideline: IEC6557 Insulation: class 2 (double insulation) Pollution degree: 2 Overvoltage category of the voltage inputs (installation/measurement): CAT III 240V to ground, 45V between inputs Overvoltage category of the AUX input: 5V to ground Max altitude: 2000m

HT FAMILY 400 METERS. Innovative meter designed to perform all safety test and power measurements on single phase system

HT FAMILY 400 METERS. Innovative meter designed to perform all safety test and power measurements on single phase system HT FAMILY 400 METERS Innovative meter designed to perform all safety test and power measurements on single phase system Description COMBI419 and COMBI420 is an innovative meter designed to perform all

More information

HT FAMILY 400 METERS. Innovative meter designed to perform all safety test and power measurements on single phase system

HT FAMILY 400 METERS. Innovative meter designed to perform all safety test and power measurements on single phase system HT FAMILY 400 METERS Innovative meter designed to perform all safety test and power measurements on single phase system Description ISO410 Insulation / Continuity meter with remote probe GEO416 Professional

More information

HT COMBI419. Innovative meter designed to perform all safety test

HT COMBI419. Innovative meter designed to perform all safety test HT COMBI419 Innovative meter designed to perform all safety test Description COMBI419 and COMBI420 is an innovative meter designed to perform all safety test verifies on electrical installations in compliance

More information

GSC57 Rel of 257/10/05

GSC57 Rel of 257/10/05 Integrated meter for test verify and Power Quality analysis Pag 1 of 7 1. ELECTRICAL SPECIFICATIONS VERIFY TESTS Accuracy is indicated as ± (% readings + no. of digits) at 23 C ± 5 C, con relative humidity

More information

PQA823 PQA824 Rel /01/2007

PQA823 PQA824 Rel /01/2007 Professional Power Quality Analyzers in compliance to EN50160 Pag 1 of 5 1. PQA82X INNOVATIVE FEATURES A wide (320x240pxls) graphical color TFT display with touch screen it s available for each model in

More information

HT FAMILY 2000 METERS. Integrated meter for test verifies on electrical installations

HT FAMILY 2000 METERS. Integrated meter for test verifies on electrical installations HT FAMILY 2000 METERS Integrated meter for test verifies on electrical installations DESCRIPTION ISOTEST200 model performs Insulation Resistance measurements on each electrical installation with test voltage

More information

PQA823 PQA824 Rel /03/2007

PQA823 PQA824 Rel /03/2007 Professional Power Quality Analyzers in compliance to EN50160 Pag 1 of 5 1. PQA82X INNOVATIVE FEATURES A wide (320x240pxls) graphical color TFT display with touch screen to surf the internal functions

More information

GSC57 & GSC53N. Integrated meter for test verify and Power Quality analysis

GSC57 & GSC53N. Integrated meter for test verify and Power Quality analysis GSC57 & GSC53N Integrated meter for test verify and Power Quality analysis DESCRIPTION GSC57 is the most complete model of the entire meters designed to verifies both on electrical installations according

More information

SOLAR300N Rel /01/10

SOLAR300N Rel /01/10 Photovoltaic installation certifier + professional network analyzer Pag 1 of 5 1. SOLAR300N MAIN FEATURES SOLAR300N performs all tests on PV plants by using of SOLAR-02 remote unit which, after a preliminary

More information

MACROTEST G1 & G2. I'm pure technology. Touch me, please.

MACROTEST G1 & G2. I'm pure technology. Touch me, please. MACROTEST G1 & G2 I'm pure technology. Touch me, please. 5 Clear answer. Complying o not. Save time! You will take half time! Color Touch Screen with icon intuitive graphics Wi-Fi and USB Power measurement

More information

PQA823 PQA824 Rel /09/18

PQA823 PQA824 Rel /09/18 Professional Power Quality Analyzers in compliance to EN50160 Pag 1 of 10 1. PQA82X INNOVATIVE FEATURES A wide (320x240pxls) graphical color TFT display with touch screen to surf the internal functions

More information

HT FAMILY M70 METERS. Advanced DMM with safety and LAN cables test verifies HT ITALIA

HT FAMILY M70 METERS. Advanced DMM with safety and LAN cables test verifies HT ITALIA HT FAMILY M70 METERS Advanced DMM with safety and LAN cables test verifies HT ITALIA HT Family M70 meters Contents: 1. Part one: M70 & M71 2. Part two: M72 & M73 3. Part three: M74 & M75 1 M70 & M71 M70:

More information

PVCHECK Rel /01/13

PVCHECK Rel /01/13 Meter for safety, functionality and performance on PV plants Pag 1 of 6 The multifunction instrument PVCHECK performs prompt and safe electrical checks required for a PV system (DC section) and controls

More information

DM-III Multitest & DM-III Multitest F Power Quality Recorders

DM-III Multitest & DM-III Multitest F Power Quality Recorders DM-III Multitest & DM-III Multitest F Power Quality Recorders CAT 600V TRUE RMSz Amprobe s full-featured Three-Phase Power Quality Recorders provide the essential functions and capabilities required to

More information

DM-III MULTITEST Power Quality Recorder

DM-III MULTITEST Power Quality Recorder DM-III MULTITEST Power Quality Recorder Amprobe s full-featured Three-Phase Power Quality Recorders provide the essential functions and capabilities required to operate accurately and effectively in today

More information

Current Clamp. 210

Current Clamp. 210 Our range of devices includes clamp meters for measuring current leaks, AC and DC current, voltage, power, resistance, continuity, capacitance or frequency. Some clamp meters have a clearly arranged display

More information

Eurotest 61557, Instaltest 61557

Eurotest 61557, Instaltest 61557 , Instaltest 61557, Instaltest 61557 Ultimate Instruments for Complete Testing of Electrical Installations Testing Measuring Analysing Recording No. 118740 VDE 0100 BS 7671 CEI 64.8 HD 384 EN 61557 VDE

More information

Revolution. PQA820 MACROTESTG3 COMBIG2 HTANALYSIS

Revolution. PQA820 MACROTESTG3 COMBIG2 HTANALYSIS Revolution. PQA820 MACROTESTG3 COMBIG2 HTANALYSIS Artificial Intelligence. Thanks to the creation of App HTanalysis it is possible to interface HT last generation instruments with tablets and smartphones.

More information

Testboy TV 416/432(A) CEE adapter*

Testboy TV 416/432(A) CEE adapter* Testboy TV 416/432(A) CEE adapter* The Testboy TV 416/432(A) is a compact CEE adapter, comprising of a combination of CEE plug (16 A or 32 A), shockproof socket and self-closing flap cover, as well as

More information

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features s Features Portable power analyzer for three-phase and single-phase electrical networks with simultaneous measurement of leakage current, power quality and recording of transients. is the best tool for

More information

Fluke 3540 FC Three-Phase Power Monitor

Fluke 3540 FC Three-Phase Power Monitor TECHNICAL DATA Fluke 3540 FC Three-Phase Power Monitor The 3540 FC Three-Phase Power Monitor is a compact device to monitor three-phase systems and stream data to the Fluke Connect Cloud. The measurement

More information

METREL Measuring and Regulation Equipment

METREL Measuring and Regulation Equipment METREL Measuring and Regulation Equipment ELECTRICAL INSTALLATION SAFETY MI 3108 EurotestPV MI 2230 VAFMeter MACHINES/APPLIANCES/SWITCHGEAR SAFETY A 1322 Active 3-phase Adapter MI 3310 SigmaGT HIGH VOLTAGE

More information

Fluke 3540 FC Three-Phase Power Monitor

Fluke 3540 FC Three-Phase Power Monitor Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com TECHNICAL DATA Fluke 3540 FC Three-Phase Power Monitor THREE-PHASE MONITORING AND STREAMING Monitor three-phase

More information

400 Series. User manual

400 Series. User manual User manual Copyright HT ITALIA 2014 Release EN 2.02-24/09/2014 EN - 1 400 Series Table of contents: 1. SAFETY PRECAUTIONS AND PROCEDURES... 4 1.1. Preliminary instructions... 4 1.2. During use... 4 1.3.

More information

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT

More information

MULTIFUNCTION TEST INSTRUMENT

MULTIFUNCTION TEST INSTRUMENT VR2250 INSTALLATION ANALYSER MULTIFUNCTION TEST INSTRUMENT USER INSTRUCTION MANUAL Page 1 of 131 TABLE OF CONTENTS 1. SAFETY PRECAUTIONS AND PROCEDURES... 5 1.1. Forwards... 5 1.2. Preliminary Instruction...

More information

Fluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents

Fluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents Versatile and rugged tools for applications with high currents Confidently take reliable readings with the True-rms, Fluke 355 and 353 digital clamp meters; the tools of choice for high current clamp-on

More information

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features s Description Features Portable power analyzer for three-phase and single-phase electrical networks with simultaneous measurement of leakage current, power quality and recording of transients. is the best

More information

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers The future of installation testing is here The Fluke 50 Series Multifunction Testers Fluke 50 Series Safer, easier installation testing. The 50 Series testers verify the safety of electrical installations

More information

Insulation Testers and Earth Ground Testers

Insulation Testers and Earth Ground Testers Insulation Testers and Earth Ground Testers With a 5000 V MegOhmMeter for industrial-strength insulation testing and a range of compact hand-held instruments, we offer a solution for every troubleshooting

More information

METRAClip87 and 88 Clamp Multimeters

METRAClip87 and 88 Clamp Multimeters 3-349-795-03 1/7.14 Current and frequency measurement via clamp meter: METRAClip87: 1500 A AC TRMS and 1500 A DC METRAClip88: 2000 A AC TRMS and 3000 A DC Multimeter functions via connector sockets: V

More information

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at USER MANUAL Model MA150 200A AC Mini Clamp-on Meter Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA150 AC Mini Clamp Meter. This device

More information

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Degree of protection (front): IP 40 Front dimensions: 9 DIN modules RS 422/485 Serial port by means of optional module Dual pulse

More information

Analog Digital Multimeter with Insulation Resistance Measurement

Analog Digital Multimeter with Insulation Resistance Measurement RISH MIT 30 Product Features: RISH MIT 30 is Analog Digital Multimeter with insulation resistance measurement, which measures VAC, VDC, VAC+DC,Frequency, ma DC, ma AC+DC,Resistance, continuity, Diode,

More information

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads Fluke 345 Power Quality Clamp Meter Technical Data The ideal meter for commissioning and troubleshooting modern electrical loads With a bright color display to analyze the harmonic spectrum, a low-pass

More information

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers MIT400 CAT IV MIT400 CAT IV CAT IV 600 V applications TRMS & DC Voltage measurement Insulation testing up to 1000 V and 200 GΩ Continuity testing at 200 ma or 20 ma down to 0.01 Ω Pass/Fail limit alarms

More information

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER 1 Energy Explorer PORTABLE POWER ANALYSERS DESCRIPTION PROFESSIONAL POWER & HARMONICS ANALYSER ENERGY EXPLORER is an advanced Power Analyser, designed for use by electricians, plant engineers and energy

More information

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC) User Manual Compact Autoranging Clamp Meters with NIST-Traceable Calibration Models 20250-55 (400 A AC), 20250-56 (400 A AC/DC) THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-55,-56 DS Clamp Meter

More information

SECULIFE SR PC Controllable Instrument for Measuring Safety-Relevant Characteristic Values of Electrical Devices /2.

SECULIFE SR PC Controllable Instrument for Measuring Safety-Relevant Characteristic Values of Electrical Devices /2. 3-349-443-03 3/2.12 Applications Testing for the Electrical Safety of Electrical Medical Devices in Accordance with the German Medical Product Law (MPG) / MDD The test instrument is used for quick and

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Power analyzers and Energy Meters Power Analyzer Type WM14-96 Power analyzers and Energy Meters Power Analyzer Type WM14-96 Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation

More information

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers MIT400 CAT IV MIT400 CAT IV CAT IV 600 V applications TRMS & DC Voltage measurement Insulation testing up to 1000 V and 200 GΩ Continuity testing at 200 ma or 20 ma down to 0.01 Ω Pass/Fail limit alarms

More information

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution

More information

Fluke 1660 Series Multifunction Installation Testers

Fluke 1660 Series Multifunction Installation Testers TECHNICAL DATA Fluke 1660 Series Multifunction Installation Testers Reduce test time up to 40 % with Auto Test Auto Test does 5 required installation tests in one sequence, including selectable Type A,

More information

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Modular versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input

More information

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement Data Sheet Analog Digital Multimeter with Insulation resistance www.rishabh.co.in Page 1 of 6 Version: J 28/12/2011 Application

More information

MS2030 CAT III 600 V A V AUTO RS232

MS2030 CAT III 600 V A V AUTO RS232 MS2030 AC Digital Clamp Meter User s Manual CAT III 600 V AUTO RS232 A V CONTENTS 1.Introduction...1 2.Safety Information...1 2.1 Precautions...1 2.2 Safety Symbols...3 3. Description...4 3.1 Front Panel...4

More information

Testers: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery:

Testers: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery: Table of Contents Testers: / Ohmmeters Insulation Measuring Instruments 51 METRAOHM 413 Article: M630A Digital Low-Resistance Measuring Instrument for Measuring Protective Conductors, Equipotential Bonding

More information

MIT415 Insulation tester

MIT415 Insulation tester MIT415 Insulation tester General features o 10V & 100V ESD testing o 25V, 50V, 250V & 500V additional ranges o Insulation testing up to 50Gohms (500V) o Continuity testing at 200mA or 20mA from 0.01ohms

More information

Custom "Compact" range with display CD20 Custom Part number

Custom Compact range with display CD20 Custom Part number Custom "Compact" range with display CD20 Custom Part number 88974051 "Modular" versions designed for Custom application-specific functions (Custom functions) LCD with 4 lines of 18 characters and configurable

More information

T 1000 PLUS Secondary Injection Relay Test Set

T 1000 PLUS Secondary Injection Relay Test Set Secondary Injection Relay Test Set Designed for testing relays and transducers Microprocessor controlled With phase angle shifter Frequency generator Test results and settings are saved into local memory

More information

User s Guide. Model MA A AC Mini Clamp-on Meter

User s Guide. Model MA A AC Mini Clamp-on Meter User s Guide Model MA150 200A AC Mini Clamp-on Meter Introduction Congratulations on your purchase of Extech s MA150 AC Mini Clamp Meter. This meter is shipped fully tested and calibrated and, with proper

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

Technical Datasheet. Delta Power 1000A / 400A AC-DC

Technical Datasheet. Delta Power 1000A / 400A AC-DC Delta 1000A / 400A AC-DC Technical Datasheet Delta 1000A/ 400A AC-DC is specially designed for Measurement of AC-DC POWER and quality parameters. Up to 49th Individual Harmonics Non contact voltage detection.

More information

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL AC/DC DIGITAL CLAMP METER OPERATION MANUAL HYS005661 A0 ACCESSORIES 6. ACCESSORIES 1) Test Leads: Electric Ratings 1000V 10A 1 pair (set) 2) Operating Manual 1 copy 3) 1.5V AAA Battery 3 piece - - 55 -

More information

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers Secondary Injection Relay Test Set Designed for testing relays and transducers Microprocessor controlled With phase angle shifter Frequency generator High power outputs Large graphical display Compact

More information

DM-45 Digital Multimeter

DM-45 Digital Multimeter INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital

More information

User manual GSC60 Copyright HT ITALIA 2017 Release EN /05/2017

User manual GSC60 Copyright HT ITALIA 2017 Release EN /05/2017 User manual Copyright HT ITALIA 2017 Release EN 1.02-16/05/2017 EN - 1 GSC60 Table of contents: 1. PRECAUTIONS AND SAFETY MEASURES... 3 1.1. Preliminary instructions... 3 1.2. During use... 4 1.3. After

More information

TORKEL 900-series Battery Load Unit

TORKEL 900-series Battery Load Unit TORKEL 900-series Batteries can be tested in service Dynamic discharge technology full power at all voltages Safety in all details, e.g. detection of blocked airflow Real time monitoring during test Easy

More information

INSULATION TESTER SERIES Selection guide

INSULATION TESTER SERIES Selection guide INSULATION TESTER SERIES Selection guide Model IR4056 IR4057 IR4053 IR4016 to IR4018 3490 3455 Basic Specifications (Bar graph) Analog Meter IR4016 IR4017 IR4018 Analog Meter backlight function 3 3 3 3

More information

ATK Clamp Meter

ATK Clamp Meter ATK-2209 Clamp Meter User s Manual Title CONTENTS Page I. SAFETY INFORMATION... 1 II. TECHNICAL SPECIFICATIONS... 2 2-1 Environment Conditions... 2 2-2 Maintenance... 2 2-3 Features... 2 2-4 General Specifications...

More information

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation Portable Description Features Measures all of the main electrical parameters of an electricity network Measurement in true root mean square Built-in energy meter With 4 voltage channels and 4 current channels

More information

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

Earth Leakage Monitoring System IsoBase IsoHub IsoOut 2014 11 21 Earth Leakage Monitoring System IsoBase IsoHub IsoOut User Manual Due to our policy of continual improvement, specifications may change without prior notice Page 2 (34) Contents Earth Leakage

More information

Installation Tester BENNING IT 130. Operating Manual

Installation Tester BENNING IT 130. Operating Manual Installation Tester BENNING IT 130 Operating Manual Manufacturer: BENNING Elektrotechnik und Elektronik GmbH & Co. KG Münsterstraße 135-137 D - 46397 Bocholt Phone: +49 (0) 2871-93 - 0 Fax: +49 (0) 2871-93

More information

1587/1577 Insulation Multimeters

1587/1577 Insulation Multimeters 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

PQube 3 Specifications

PQube 3 Specifications PQube 3 Specifications Reference conditions for factory tests: 19~25 C, 10%~70% RH MAINS VOLTAGE MEASURING CHANNELS Measurement Channels Power Configuration/ Range of Nominal Input Voltage 3 Line to Neutral,

More information

Pen-type DIGITAL MULTITESTER

Pen-type DIGITAL MULTITESTER BST-MT267 Pen-type DIGITAL MULTITESTER INSTRUCTION MANUAL Index 1. Introduction... 2. Safety Notes... 3. Features... 4. Specifications... 5. General... 6. Instrument Layout... 7. Measurement... 8. Maintenance...

More information

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards Keeping up with the standards C.A 8352 Power Quality Monitor Complete electrical network analysis at the tips of your fingers! All measurements for complete analysis: powers, harmonics, flicker, symmetry,

More information

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Power analyzers and Energy Meters Multifunction indicator Type WM12-DIN Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase

More information

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers MIT400/2 Designed for electrical and industrial testing Insulation testing up to 1000 V and 200 GΩ range Stabilized insulation test voltage (New) Single range, faster continuity testing from 0.01 Ω to

More information

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 800 Amp AC/DC True RMS Clamp Meter Model EX730 Introduction Congratulations

More information

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User s Guide. 400A AC/DC Clamp Meter. Model MA220 User s Guide 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting the Extech MA200 AC/DC Clamp Meter. This meter measures AC/DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,

More information

PROFiTEST C Test Instrument per DIN VDE /11.10

PROFiTEST C Test Instrument per DIN VDE /11.10 3-349-075-03 15/11.10 Testing of Residual-Current Devices (RCDs) Measures contact voltage without tripping the RCCB. Contact voltage relative to nominal residual current is measured with 1 / 3 nominal

More information

MIT400/2 CAT IV Insulation testers

MIT400/2 CAT IV Insulation testers MIT400/2 CAT IV Insulation testers MIT400/2 CAT IV Insulation testers Designed for Electrical and Industrial testing Insulation testing up to 1000 V and 200 GΩ range Stabilised insulation test voltage

More information

The first installation safety tester with automated testing based on patent pending AUTO SEQUENCE.

The first installation safety tester with automated testing based on patent pending AUTO SEQUENCE. EurotestAT MI 3101 The first installation safety tester with automated testing based on patent pending AUT SEQUENCE. Concentrate on your work instead on the instruction manual of your test instrument.

More information

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

TRMS LEAKAGE CURRENT CLAMP-ON METER 565 TRMS LEAKAGE CURRENT CLAMP-ON METER 565 E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards

More information

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers MIT400 CAT IV Industrial Insulation Testers MIT400 CAT IV Industrial Insulation Testers CAT IV 600 V applications Insulation testing up to 1000 V and 200 GΩ Continuity testing at 200 ma or 20 ma down to

More information

Technical Data Sheet AMIK 300 / 301

Technical Data Sheet AMIK 300 / 301 USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important

More information

C.A 6117 C.A 6116N C.A 6113 Multi-function installation testers

C.A 6117 C.A 6116N C.A 6113 Multi-function installation testers C.A 6117 C.A 6116N C.A 6113 Multi-function installation testers in Safety for your electrical installations, high performance of a unique instrument. 600 V CAT III Testing according to the international

More information

ENGLISH. User manual

ENGLISH. User manual ENGLISH User manual Copyright HT ITALIA 2017 Version EN 1.00-03/10/2017 IT - 1 JUPITER Table of contents: 1. PRECAUTIONS AND SAFETY MEASURES... 2 1.1. Preliminary instructions... 2 1.2. During use...

More information

Flexible AC current probes

Flexible AC current probes Flexible AC current probes Making use of the principle of Rogowski coils, the MiniFLEX models are flexible sensors offering a wide dynamic range for measuring AC intensities and viewing high-speed current

More information

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output. Power analyzers and Energy Meters Multifunction indicator Type WM12-96 Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase

More information

TORKEL 900-series Battery Load Unit

TORKEL 900-series Battery Load Unit Batteries can be tested in service Dynamic discharge technology full power at all voltages Safety in all details, e.g. detection of blocked airflow Real time monitoring during test Quick report Easily

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com #61-732 #61-736 400 AAC Clamp Meter Instruction Manual AC HOLD APO DC KMΩ mva WARNING Read First: Safety Information Understand

More information

3 PHASE DIGITAL POWER CLAMP METER USERS MANUAL

3 PHASE DIGITAL POWER CLAMP METER USERS MANUAL PHASE DIGITAL POWER CLAMP METER USERS MANUAL CONTENTS Safety Precautions - - - - - - - - - - - - - - - - - - - - - - - - - - - Safety Information - - - - - - - - - - - - - - - - - - - - - - - - - - - Safety

More information

The future of installation testing is here. The 1650 Series Multifunction Testers

The future of installation testing is here. The 1650 Series Multifunction Testers The future of installation testing is here The 50 Series Multifunction Testers 50 Series Safer, easier installation testing. Robin and Fluke joined forces in 999 to become the largest supplier of hand-held

More information

AC/DC CLAMP METER USER S MANUAL

AC/DC CLAMP METER USER S MANUAL AC/DC CLAMP METER USER S MANUAL CONTENTS PAGE SAFETY INFORMATION SYMBOL EXPLANATION SAFETY PRECAUTIONS 1 1 2 MAINTENANCE 3 GENERAL DESCRIPTION 4 PANEL DESCRIPTION 4 OPERATING INSTRUCTIONS... 7 SPECIFICATIONS

More information

MEASURING INSTRUMENTS AND TESTERS

MEASURING INSTRUMENTS AND TESTERS MEASURING INSTRUMENTS AND TESTERS Electrical Installation Safety High Voltage Insulation / Continuity / Earth Appliance / Machine / Switchboard Safety Power Quality Analysis LAN Cabling Certification Indoor

More information

GAMMA 20 DIGITAL MULTIMETER

GAMMA 20 DIGITAL MULTIMETER Gamma 20 www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel

More information

OPERATOR S INSTRUCTION MANUAL

OPERATOR S INSTRUCTION MANUAL OPERATOR S INSTRUCTION MANUAL AUTO-RANGE DUAL DISPLAY CONFORMED IEC1010 DIGITAL MULTIMETER CONTENTS PAGE SAFETY INFORMATION..... DESCRIPTION.. OPERATING INSTRUCTION.. SPECIFICATIONS.... ACCESSORIES. BATTERY

More information

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com USER'S MANUAL ACDC-100 TRMS ACDC-100 Versatile AC/DC Clamp-on Multimeter Series 1 1) SAFETY This manual contains information

More information

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming Energy Management Type WM14 DI version Protection degree (front): IP40 2 digital outputs 16 freely configurable alarms with OR/AD logic linkable with up to 2 digital outputs RS422/485 serial output (MODBUS-RTU),

More information

INSTRUCTION MANUAL DIGITAL PSC-LOOP TESTER MODEL 4118A KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD.

INSTRUCTION MANUAL DIGITAL PSC-LOOP TESTER MODEL 4118A KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD. INSTRUCTION MANUAL DIGITAL PSC-LOOP TESTER MODEL 4118A KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD. CONTENTS 1. SAFE TESTING... 1 2. PROCEDURE OF REMOVING COVER... 4 3. FEATURES... 5 3.1 Instrument Layout...

More information

Gx Series. User manual

Gx Series. User manual User manual Copyright HT ITALIA 2015 Release EN 2.03-06/03/2015 EN - 1 Gx Series Table of contents: 1. PRECAUTIONS AND SAFETY MEASURES... 3 1.1. Preliminary instructions... 3 1.2. During use... 4 1.3.

More information

02/11/2015

02/11/2015 "Compact" range with display CD12 Part number 88970041 Green LCD with 4 lines of 18 characters and configurable backlighting More cost effective solution Industrial temperature range (-20 C +55 C) Analogue

More information

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality

More information

Multi range AC current clamps (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no

Multi range AC current clamps (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no. 20 751 696 Distributor: Manufacturer: METREL d.d. Ljubljanska cesta 77 1354 Horjul Slovenia web site: http://www.metrel.si e-mail:

More information

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY

More information

Fluke and

Fluke and Fluke 1623-2 and 1625-2 GEO Earth Ground Testers Technical Data The new Fluke 1623-2 and 1625-2 GEO Earth Ground Testers offer data storage and download capabilities via USB port. World class accessories

More information

DM-5 Power Quality Analyzer

DM-5 Power Quality Analyzer amprobe.com DM-5 Power Quality Analyzer With Feature Packed Software, most Compact High Performance Power Quality Analyzer in its Class Poor power quality is costly not only can it drive up energy bills

More information