Emerson Process Management - CSI
|
|
- Vernon Golden
- 6 years ago
- Views:
Transcription
1 Page 1 of 15 DoctorKnow Application Paper Title: Characterizing Shaft Misalignment Effects Using Dynamic Measurements Source/Author:Dan Nower & Curt Thomas Product: Corrective Technology: Corrective Classification: Biographies CHARACTERIZING SHAFT MISALIGNMENT EFFECTS USING DYNAMIC MEASUREMENTS By Dan Nower, P.E. & Curt Thomas Computational Systems, Incorporated Dan Nower is an Applied Development Engineer in the Engineering Division at Computational Systems, Incorporated. He is responsible for the development of the alignment product line. Dan has over ten years of alignment and vibration analysis experience. He received a BS in Mechanical Engineering from the University of Missouri-Rolla He is a registered engineer in the state of Tennessee, an associate member of ASME, has published several papers and is the holder of two alignment related patents. Curt Thomas is a Consultant working with Computational Systems, Incorporated. He is responsible for much of the testing of all alignment products. Curt has two years experience in the alignment area. His prior experience includes steam turbine-generator repair work and a construction engineer in the U.S. Army. He has a BS in Mechanical Engineering from the Georgia Institute of Technology Abstract A test system has been developed for measuring the effects of shaft misalignment under a variety of common field conditions. This system allows five common types of couplings to be tested under loaded conditions for both offset and parallel misalignment in the horizontal and vertical directions. The dynamic measurements that were collected include vibration spectral and waveform data, axial and radial phase data at 1x, 2x and 3x RPM, motor current data, and temperature data. This information should be extremely useful when troubleshooting possible misalignment problems Introduction We all know the importance of proper shaft alignment. Misalignment can lead to excessive vibration and stresses, premature component failures, and eventually shortened life spans of machines, Finding misalignment while a machine is shutdown is not often difficult. Just measure the misalignment with a reliable alignment system. But what about the step prior to this, when the machine is operating? Most of us are familiar with the traditional vibration analysis rules: 1. 2x running speed amplitude -Radial direction for offset misalignment -Axial direction for angular misalignment -Most misalignments are a combination of the two, so 2x in any direction
2 Page 2 of and 180 Phase Shifts Radial direction for offset misalignment Axial direction for angular misalignment How accurate are these rules? Is the 2x RPM peak always a good indicator?. How does the coupling design affect the shape of the spectral information? Do the phase rules work? If so, how much misalignment does it take to cause the phases to shift?
3 Page 3 of 15 Beyond the traditional rules, those that are involved in the alignment area have noticed interesting phenomena with respect to motor current, and temperature. Little has been documented on these parameters. This undertaking monitored these parameters, but this paper deals mainly with the accuracy of the traditional rules on a limited number of couplings and touches briefly upon motor current and temperature results. Previous Work Dewell, David L., "Detection of a Misaligned Metallic Disc Flexible Coupling Using Real Time Spectrum Analysis." Master Thesis, Virginia Polytechnic Institute and State University, March Lorenc, Jerome A., "Changes in Pump Vibration Levels Caused by The Misalignment of Different Style Couplings." Proceedings, Eight International Pump Users Symposium, Houston Texas, March Nower Daniel L., "Preliminary Report on Characterizing Shaft Misalignment Effects Using Dynamic Measurements", Presented at the Vibration Institute Meeting, Wilmington, Virginia, June Piotrowski, John D., "How varying Degrees of Misalignment Affect Rotating Machinery - A Case Study." Proceedings, Machinery Vibration Monitoring and Analysis Meeting, New Orleans Louisiana, June Test Machine & Couplings The configuration of the test machine is shown in Figure 3. The motor drove the generator which provided power to the heating element located below the motor. Much care was taken to correct for soft foot. The couplings tested are listed in Table 1 along with their manufacturer's recommended alignment tolerances. MOTOR: Dayton 1 Hp 3450 RPM Loaded, 3550 Rpm Unloaded 15 amps, full load 60 Hz, Single-Phase 115 Volts 28 Rotor Bars 24 Stator Slots Anti-Friction Bearings Loaded by heating element located underneath
4 Page 4 of 15 GENERATOR: Dayton 360O RPM 16.7 amps, maximum 60 Hz, Single-Phase 120 Volts 2 Kilowatt Anti-Friction Bearings Provides power to heating element Parameters Monitored Misalignment Conditions Besides the aligned condition, the machine was increasingly misaligned in the vertical and horizontal directions. The pure offset misalignments were typically 10, 25, and 50 mils, and pure angle misalignments were typically 1,5, and 15 mils/inch (17.45 mils/inch = 1 ) Vibration & Motor Current Vibration spectra and time waveforms were gathered using normal averaging and high resolution time synchronous averaging. Time synchronous averaging was utilized because the high level of electrical signals generated by the single-phase motor.
5 Page 5 of 15 Motor current was gathered in different frequency spans and resolutions to monitor the line and rotor bar frequencies. Phases Phase at 1x, 2x, and 3x RPM were monitored in the radial and axial directions. The outboard axial readings were taken around the clock face, at 12, 3, 6, and 9 o'clock Inboard axial readings were also taken. If phases did not stabilize after one minute, phase at that point and speed was labeled "unstable". Temperature Temperature was measured at the end of each misalignment route, which took about 2% hours to complete. Temperature was measured with an infrared temperature probe at all bearings and at the coupling hubs. Amplitude & Spectral Results General The amplitude data was analyzed to locate those multiples of running speed that provided the highest levels and those that trended upward as the misalignment increased. Harmonics up to 8x were reviewed, but only up to 6x was included in the analysis since amplitudes at 7x and 8x were so small. The amplitudes were sorted into blocks by increasing amounts of offset and angular misalignment. If the amplitudes in each block trended upward it was flagged as good indicator. The number of good blocks and the highest amplitudes determined which harmonic of running speed was the best indicator for each coupling. Table 3 shows the results for each coupling. The Grid coupling had the best misalignment response with 63% of the amplitude blocks trending upward. The Shim coupling was the worst with 12.5%.
6 Page 6 of 15 Rotor bar frequencies (24x and 28x) were also reviewed. They did not show an upward trend as the misalignment increased in any direction. Outboard measurement points trended misalignment as often as inboard measurement points, however the highest amplitudes were found at the inboard bearings. Also, no correlation was found with respect to: a Angular misalignment more prone to revealed itself in the axial direction and offset misalignment in radial direction. b. Vertical misalignment affects the horizontal measurement points and visa versa. Bun Coupling The spectra shown are from point Generator Inboard Horizontal (GIH) as the horizontal offset misalignment increased from the aligned condition to 75 mils. This point provided the most reliable spectral data and also provided the best upward trend. The spectral content shown in Figure 5 is typical of this coupling. As shown in the data, 2x times running speed proved to be the most consistent misalignment indicator for this coupling. The highest amplitudes (0.292 ips-pk) were generated at GIH as the machine was offset in the vertical direction 75 mils (12.5 mils above tolerance). Based upon the data the following was concluded for this coupling: 1. 2x RPM was the best amplitude to track to find misalignment as a whole. 2. Horizontal misalignment was difficult to find. 3. 1x RPM was not much help. Jaw Coupling The spectra shown in Figure 6 are from measurement points Generator Inboard Axial (GIA) as the horizontal angular misalignment increased. The offset misalignment was increased to 25 mils (10 mils above tolerance) and the angular was increased to 15 mils/inch (0.86 ). These spectra show the typical
7 Page 7 of 15 high harmonic content that was generated while the jaw coupling was in service. Amplitudes at 2)( RPM were much lower, but the overall energy generated was high. 3x and 5x prove to be the best harmonics to track a misaligned condition. Amplitudes at 3x reached 0.09 ips, pk at GIA and GIH, caused by both angular and offset misalignment Amplitudes at 5x reached 0.12 and 0.15 ips, pk at GIV and GIH, caused by both angular and offset misalignment. Based upon the data the following was concluded for this coupling: 1. 3x RPM was the best amplitude to track to find misalignment as a whole. 2. 5x RPM was a good indicator in this case because of the frequency response function (FRF). 3. Horizontal and vertical misalignment was just as easy to find when 3x is tracked. 4. 1x RPM was not much help. Shim Coupling The spectra shown in Figure 7 are from the measurement point Motor Outboard Vertical (MOV) as the horizontal angular misalignment increased. The offset misalignment was increased to 50 mils and the angular was increased to 15 mils/inch (0.86 ). This was the quietest and smoothest running coupling tested. All amplitudes were low. The highest amplitude was ips-pk at 2x on measurement point GIH in the aligned condition. Typically the amplitudes were highest at 2x running speed, but were typically down around 0.01 ips-pk. Consistent upward trends were difficult to find, with 6x the best indicator. Amplitude trends typically decreased as the misalignment increased and started to increase at the maximum misalignment.
8 Page 8 of 15 Based upon the data the following was concluded for this coupling: 1. 6x RPM was the best amplitude to track to find misalignment as a whole However its track record was not good, correct only 30% of time. 2x RPM had the highest amplitudes, but did not typically (only 10%) trend upward. 2. Any misalignment was difficult to find. Therefore, caution should be used when using this coupling. The vibration maybe low, however stresses are still working on the critical components. 3. 1x RPM was not much help. Another machine with this type of coupling was tested at a customer's facility. The machine was a 700 Hp induction motor driving a multi-stage pump. The response was measured from several misaligned conditions. The amplitude and spectral response generated similar information. No amplitudes trended upward as the misalignment increased. A typical set of spectra are shown in Figure 8.
9 Page 9 of 15 Grid Coupling The spectra shown in Figure 9 are from measurement points Generator Inboard Vertical (GIV) as the horizontal offset misalignment increased. The offset misalignment was increased to 50 mils and the angular was increased to 15 mils/inch (0.86 ). These spectra show that the 4x RPM peak is a good indicator of the amount of misalignment, with the maximum amplitude of ips-pk showing up at GIV with 50 mils of offset in the horizontal direction. Not only did the 4x harmonic peak generate the highest amplitudes, but also showed an upward trend as the misalignment increased 80% of the time. Accuracy (trended upward) of the 1x and 2x RPM peaks were 35% and 60%, respectively.
10 Page 10 of 15 Based upon the data the following was concluded for this coupling: 1. 4x RPM was the best amplitude to track to find misalignment as a whole. Also producing the highest amplitudes. 2. Misalignment was not difficult to find. 3. 1x RPM was not much help. Rubber Internal Gear Coupling This was also a quiet and smooth operating coupling. Again, all amplitudes were low. The highest amplitude was ips-pk at 2)( RPM at measurement point GIH which was misaligned by 15 mils/inch in the horizontal direction. Typically the amplitudes were highest at 2)( running speed, but were typically down around 0.01 ips-pk. As shown in Figure 10, consistent upward trends were difficult to find, with 6)( being the best indicator. Amplitude trends typically increased as the misalignment increased but upward trends ware minimal, typically starting at ips-pk and increasing to ips-pk. Based upon the data the following was concluded for this coupling: 1. 6x RPM was the best amplitude to track to find misalignment as a whole. However its track record was not excellent, correct 53% of time. 2x RPM had the highest amplitudes and trended upward 43% of the time. 2. Any misalignment was difficult to find since the synchronous amplitudes ware so low. Therefore, caution should be used when using this coupling. The vibration maybe low, however stresses are still working on the critical components. 3. 1x RPM was not much help. Another machine with this type of coupling was tested at a customer's facility. The machine was a 100 Hp induction motor driving a single stage centrifugal water pump. We measured the response from several misaligned conditions. The amplitude and spectral response generated similar information. This being small upward trends with increased misalignment and 2x being the best indicator. A typical set of spectra are shown in Figure 11.
11 Page 11 of 15 Phase Results It was difficult to decide how to reduce all the phase data down into something practical, Phase differences were calculated across the coupling for the axial and radial measurement points, Phase differences were also calculated from end-to-end of the motor and the generator. These differences sorted by the type of coupling, type of misalignment, and misalignment direction. Each group was considered a phase block. A phase shift was flagged if it was a multiple of 180, ±15 Unstable phases were not considered in phase shift calculations. Total phase accuracy was calculated by taking all 180 phase shifts and dividing by the total number of times a phase shifts could have occurred. The phase block accuracy was determined by dividing the number of phase blocks that shifted by the total number of applicable phase blocks. If just the raw percentages are reviewed (see Table 4), phase analysis does not appear to be a good indicator of misalignment. The numbers typically ran in the low to mid 20% range. Phase indicated misalignment the best on the Jaw Coupling and the worst on the Rubber Gear Coupling.
12 Page 12 of 15 However, the percent accuracy is not how the phase is typically used in the field. It is utilized by determining the number of 180' phase shifts measured during operation. The greater the number of 180' phase shifts the more likely that a misaligned condition does exist. The results of this are shown in the final column of Table 4. The number of phase shifts increased in some of the couplings as the misalignment increased to a certain point. A YES is logged in the above table for those that did. It is interesting to note that for the maximum misalignments (50 mils offset and 15 mils/inch angle) the number of phase shifts per condition decreased. Also there appears to be a relationship between the accuracy percentages and the phase shifts, with the cut off point being around 15% Tests on the 100 Hp and 700 Hp machines produced similar results. The results from the 700 Hp machine (which used a shim type coupling) were: Total Accuracy = 20%, Block Accuracy = 40%, and the number of phase shifts did increase with the amount of misalignment. The 100 Hp machine (which used a shim type coupling) results were: Total Accuracy = 7%, Block Accuracy = 0%, and the number of phase shifts did not increase with the amount of misalignment. Motor Current Results We believe that the motor current portion of the experiment actually raised more questions than it answered. It was expected that by measuring the motor current it could be determined that proper alignment can save money by reducing the amount of wasted energy consumed to overcome forces induced by misalignment. This held true for the Bun coupling. With higher degrees of misalignment, the motor current increased small amounts, ranging from 2.1% to 4.9%. The savings typically did not increase as the misalignment increased This raises a question, Are the saving percentages the same for larger machines if they are properly aligned? Jaw coupling motor current results did differ from the bun coupling. All motor currents at line frequency decreased as the misalignment increased, opposite of what was expected. This was true regardless of the type or direction of misalignment. However, "two times slip" sidebands around line frequency and all harmonics of line frequency increased in amplitude. The increase in amplitudes occurred during the initial misalignment and remained at that those levels. They did not increase as the misalignment Increased. The remaining couplings produced wild results. The motor currents varied up and down as the misalignment increased. Further investigation revealed that the electrical system under test did not have a stiff voltage. When the system was loaded, the voltage was pulled down significantly. In order to compensate for this, voltage and input power factor should have been measured, but was not. Also, the '"two times slip" sidebands did not react as they did with the Jaw coupling. All delta amplitudes (between
13 Page 13 of 15 the line amplitude and the lower sideband amplitude) remained stable as the misalignment increased. The Shim Coupling remained around 49 db, the Grid Coupling around 47 db, and the Rubber Gear around 51 db. Temperature Results As with the other measured parameters (vibration, motor current, and phase) the temperature response to misalignment varied with the type of coupling. Some indicated misalignment well, especially when looking at the coupling temperature. Table 5 below shows how the couplings ranked using temperature as a misalignment indicator. The All Points Block Accuracy is the number of temperature blocks that showed an upward trend divided by the total number of chances. This includes the temperatures at the motor bearings, generator bearings and the coupling hubs. Considering all couplings, the coupling measurement point showed the most consistency, therefore the Coupling Temperature Block Accuracy column shows how often this particular location showed an upward trend. The table shows that the Grid coupling was the best of the couplings tested and the shim coupling was the worst. Results from the larger machines (700 Hp and 100 Hp) showed similar results. Coupling block results on the shim coupling (700 Hp) and the rubber gear coupling (100 Hp) were 0% These two couplings also performed poorly as an indicator in the above data. Conclusions Amplitude and Spectral Probably the most significant item learned from this experiment is that the spectral information generated by a machine is very dependent upon the type of coupling. Figure 12 shows a set of spectra from the same measurement point (GIH) with similar misaligned conditions. Troubleshooting personnel should take this into consideration while doing their job. Also beware of the type of coupling being used prior to performing running alignments or running soft foot checks. CSI does not condone these type of checks. Phase Analysis When looking at the number of phase shifts over the complete machine, phase analysis is a good indicator for several couplings and not for others. So, before performing this type of analysis know what type of flexible coupling is used on the machine being tested. See Table 4 for results on each coupling. Motor Current Hopefully you can learn from our mistakes. Much care has to be taken when determining the effects of misalignment on the efficiency of the total machine. Just measuring motor current is not enough. To determine the effects the machine, it should be operated at the same load before and after alignment. For
14 Page 14 of 15 example, a motor-pump combination should be operated at the same flow rate before and after. Also, if the machine is not on a stiff (with respect to voltage) system, measure voltage and input power factor. The proper amount of savings can be calculated from this information. Temperature If using temperature as a misalignment indicator you should be aware of what type of coupling is installed on the machine, see Table 5 to see those couplings tested. Also, the best measurement point location is the coupling itself, preferably one of the coupling hubs. Be sure to use a non-contact method, such as infrared, to measure since the coupling is rotating. Some of the upward trends found were small. The increase is small enough that a variation in ambient temperature or the process could affect the temperature more than the misaligned condition. These parameters were held constant during the test, but the process may have affected the results from the large machines. General It is evident from the data that the troubleshooter in the field should always be aware of the type of flexible coupling being used before any final decisions are made. Different couplings affect the spectral shape (Figure 12), phase (Table 4), motor current, and temperature (Table 5) During the test, responses were measured within three operating hours of the initial startup for each condition. Misalignment maybe like heart disease, it maybe required to operate in a poor condition awhile before symptoms start showing up. In the case of misalignment, time to allow the misalignment stresses to open up clearances Most of the results generated from this experiment were from a machine smaller than the typical machine in the field Further testing should be performed on larger machines using the same type couplings. Some tests have been performed with the shim and rubber gear designs, which confirmed most of the results obtained from the small machine.
15 Page 15 of 15 All contents copyright , Computational Systems, Inc. All Rights Reserved.
Vibration based condition monitoring of rotating machinery
Vibration based condition monitoring of rotating machinery Goutam Senapaty 1* and Sathish Rao U. 1 1 Department of Mechanical and Manufacturing Engineering, Manipal Institute of Technology, Manipal Academy
More informationCHAPTER 5 FAULT DIAGNOSIS OF ROTATING SHAFT WITH SHAFT MISALIGNMENT
66 CHAPTER 5 FAULT DIAGNOSIS OF ROTATING SHAFT WITH SHAFT MISALIGNMENT 5.1 INTRODUCTION The problem of misalignment encountered in rotating machinery is of great concern to designers and maintenance engineers.
More informationPeakVue Analysis for Antifriction Bearing Fault Detection
Machinery Health PeakVue Analysis for Antifriction Bearing Fault Detection Peak values (PeakVue) are observed over sequential discrete time intervals, captured, and analyzed. The analyses are the (a) peak
More informationIntroduction*to*Machinery*Vibration*Sheet*Answer* Chapter*1:*Vibrations*Sources*and*Uses*
IntroductiontoMachineryVibrationSheetAnswer Chapter1:VibrationsSourcesandUses 1. 1. imposed motions related to the function - e.g. slider crank and earn 2. inadequate design - e.g. resonance 3. manufacturing
More informationPresented By: Michael Miller RE Mason
Presented By: Michael Miller RE Mason Operational Challenges of Today Our target is zero unplanned downtime Maximize Equipment Availability & Reliability Plan ALL Maintenance HOW? We are trying to be competitive
More informationAn Introduction to Time Waveform Analysis
An Introduction to Time Waveform Analysis Timothy A Dunton, Universal Technologies Inc. Abstract In recent years there has been a resurgence in the use of time waveform analysis techniques. Condition monitoring
More informationApplication of Electrical Signature Analysis. Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN
Application of Electrical Signature Analysis Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN Introduction Over the past months we have covered traditional and modern methods of testing electric
More informationA Novel Approach to Electrical Signature Analysis
A Novel Approach to Electrical Signature Analysis Howard W Penrose, Ph.D., CMRP Vice President, Engineering and Reliability Services Dreisilker Electric Motors, Inc. Abstract: Electrical Signature Analysis
More informationCHAPTER 7 FAULT DIAGNOSIS OF CENTRIFUGAL PUMP AND IMPLEMENTATION OF ACTIVELY TUNED DYNAMIC VIBRATION ABSORBER IN PIPING APPLICATION
125 CHAPTER 7 FAULT DIAGNOSIS OF CENTRIFUGAL PUMP AND IMPLEMENTATION OF ACTIVELY TUNED DYNAMIC VIBRATION ABSORBER IN PIPING APPLICATION 7.1 INTRODUCTION Vibration due to defective parts in a pump can be
More informationVibration History. Pulp & Bleach Area. ips. Average Amplitude Velocity. Year
Average Amplitude Velocity ips 0.26 0.25 0.24 0.23 0.22 0.21 0.2 0.19 0.18 0.17 0.16 0.25 Vibration History Pulp & Bleach Area 0.21 0.19 0.17 0.16 1 2 3 4 5 1980 1981 1982 1983 1984 Year R&E Maintenance
More informationPredictive Maintenance with Multi-Channel Analysis in Route and Analyze Mode
Machinery Health Management Predictive Maintenance with Multi-Channel Analysis in Route and Analyze Mode Presented at EuroMaintenance 2014, Helsinki, Finland, by Johan Van Puyenbroeck. Traditional route-based
More informationMachinery Fault Diagnosis
Machinery Fault Diagnosis A basic guide to understanding vibration analysis for machinery diagnosis. 1 Preface This is a basic guide to understand vibration analysis for machinery diagnosis. In practice,
More informationRESEARCH PAPER CONDITION MONITORING OF SIGLE POINT CUTTING TOOL FOR LATHE MACHINE USING FFT ANALYZER
RESEARCH PAPER CONDITION MONITORING OF SIGLE POINT CUTTING TOOL FOR LATHE MACHINE USING FFT ANALYZER Snehatai S. Khandait 1 and Prof.Dr.A.V.Vanalkar 2 1 P.G.Student,Department of mechanical KDK College
More informationA Hoist Application. Mining Industry
CASE STUDY A Hoist Application in the Mining Industry by Tim Sundström Research & Development, SPM Instrument AB January, 2014 2 (21) Contents 1 Introduction... 3 2 Conclusion and summary... 5 3 Application
More informationI I. Early Shaft Crack Detection On Rotating Machinery Using Vibration Monitoring and Diagnostics _. ) region. acceptance
BENTLY(\ NEVADA V TECHNICAL BULLETIN Early Shaft Crack Detection On Rotating Machinery Using Vibration Monitoring and Diagnostics o acceptance region I I 270......_ / 1X amplitude and phase~~...,;v...,;;",e~ct~o,;;""",ilr
More informationHigh Vibration Analysis of Eddy Current Drum Coupled Motor to a Vertical Centrifugal Pump Solution Based on EMA, ODS and FEA By:
Juan Gamarra Mechanical Solutions, Inc. High Vibration Analysis of Eddy Current Drum Coupled Motor to a Vertical Centrifugal Pump Solution Based on EMA, ODS a FEA By: Jody Barksdale, PE Juan R. Oqueo,
More informationCASE STUDY: Roller Mill Gearbox. James C. Robinson. CSI, an Emerson Process Management Co. Lal Perera Insight Engineering Services, LTD.
CASE STUDY: Roller Mill Gearbox James C. Robinson CSI, an Emerson Process Management Co. Lal Perera Insight Engineering Services, LTD. ABSTRACT Stress Wave Analysis on a roller will gearbox employing the
More informationCONSIDERATIONS FOR ACCELEROMETER MOUNTING ON MOTORS
SENSORS FOR MACHINERY HEALTH MONITORING WHITE PAPER #49 CONSIDERATIONS FOR ACCELEROMETER MOUNTING ON MOTORS ACCELEROMETER SELECTION AND MOUNTING RECOMMENDATIONS FOR VIBRATION ANALYSIS OF MOTORS IN THE
More informationGenerator Advanced Concepts
Generator Advanced Concepts Common Topics, The Practical Side Machine Output Voltage Equation Pitch Harmonics Circulating Currents when Paralleling Reactances and Time Constants Three Generator Curves
More informationBeating Phenomenon of Multi-Harmonics Defect Frequencies in a Rolling Element Bearing: Case Study from Water Pumping Station
Beating Phenomenon of Multi-Harmonics Defect Frequencies in a Rolling Element Bearing: Case Study from Water Pumping Station Fathi N. Mayoof Abstract Rolling element bearings are widely used in industry,
More informationHow Plant Rotating Equipment Resonance Issues Can Affect Reliability and Uptime
How Plant Rotating Equipment Resonance Issues Can Affect Reliability and Uptime Eric Olson, Principal Engineer, Mechanical Solutions, Inc. Maki Onari, Principal Engineer, Mechanical Solutions, Inc. Chad
More informationIMPACT DEMODULATION. An Over-Sampling Signal Processing Technique Used to Diagnose Bearing Faults
IMPACT DEMODULATION An Over-Sampling Signal Processing Technique Used to Diagnose Bearing Faults 2018 by Azima. All Rights Reserved. Part Number: 80004240-1 AZIMA DLI HEADQUARTERS: 300 Trade Center, Suite
More informationBLADE AND SHAFT CRACK DETECTION USING TORSIONAL VIBRATION MEASUREMENTS PART 2: RESAMPLING TO IMPROVE EFFECTIVE DYNAMIC RANGE
BLADE AND SHAFT CRACK DETECTION USING TORSIONAL VIBRATION MEASUREMENTS PART 2: RESAMPLING TO IMPROVE EFFECTIVE DYNAMIC RANGE Kenneth P. Maynard, Martin Trethewey Applied Research Laboratory, The Pennsylvania
More informationAnalysis Of Induction Motor With Broken Rotor Bars Using Discrete Wavelet Transform Princy P 1 and Gayathri Vijayachandran 2
Analysis Of Induction Motor With Broken Rotor Bars Using Discrete Wavelet Transform Princy P 1 and Gayathri Vijayachandran 2 1 Dept. Of Electrical and Electronics, Sree Buddha College of Engineering 2
More informationBearing fault detection of wind turbine using vibration and SPM
Bearing fault detection of wind turbine using vibration and SPM Ruifeng Yang 1, Jianshe Kang 2 Mechanical Engineering College, Shijiazhuang, China 1 Corresponding author E-mail: 1 rfyangphm@163.com, 2
More informationAutomated Bearing Wear Detection
Mike Cannon DLI Engineering Automated Bearing Wear Detection DLI Engr Corp - 1 DLI Engr Corp - 2 Vibration: an indicator of machine condition Narrow band Vibration Analysis DLI Engr Corp - 3 Vibration
More informationSYNCHRONOUS MACHINES
SYNCHRONOUS MACHINES The geometry of a synchronous machine is quite similar to that of the induction machine. The stator core and windings of a three-phase synchronous machine are practically identical
More informationPractical Machinery Vibration Analysis and Predictive Maintenance
Practical Machinery Vibration Analysis and Predictive Maintenance By Steve Mackay Dean of Engineering Engineering Institute of Technology EIT Micro-Course Series Every two weeks we present a 35 to 45 minute
More informationROTOR FAULTS DETECTION IN SQUIRREL-CAGE INDUCTION MOTORS BY CURRENT SIGNATURE ANALYSIS
ROTOR FAULTS DETECTION IN SQUIRREL-CAGE INDUCTION MOTORS BY CURRENT SIGNATURE ANALYSIS SZABÓ Loránd DOBAI Jenő Barna BIRÓ Károly Ágoston Technical University of Cluj (Romania) 400750 Cluj, P.O. Box 358,
More informationAGN 008 Vibration DESCRIPTION. Cummins Generator Technologies manufacture ac generators (alternators) to ensure compliance with BS 5000, Part 3.
Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 008 Vibration DESCRIPTION Cummins Generator Technologies manufacture ac generators (alternators) to ensure compliance
More informationAlso, side banding at felt speed with high resolution data acquisition was verified.
PEAKVUE SUMMARY PeakVue (also known as peak value) can be used to detect short duration higher frequency waves stress waves, which are created when metal is impacted or relieved of residual stress through
More informationStatistical analysis of low frequency vibrations in variable speed wind turbines
IOP Conference Series: Materials Science and Engineering OPEN ACCESS Statistical analysis of low frequency vibrations in variable speed wind turbines To cite this article: X Escaler and T Mebarki 2013
More informationMECH-303: Gaskets, Packing and Mechanical Seal Failures Analysis
MECH-303: Gaskets, Packing and Mechanical Seal Failures Analysis Abstract The early detection and prevention of catastrophic bearing and seal failures alone has justified the existence of predictive maintenance
More informationApplications Note. Bently Nevada* Asset Condition Monitoring. Periodically Monitored Assets. Connecting SCOUT to Continuous Monitoring Systems
Bently Nevada* Asset Condition Monitoring Connecting SCOUT to Continuous Monitoring Systems The most effective installations of continuous monitoring instruments such as the 3500 system include integration
More informationAUTOMATED BEARING WEAR DETECTION. Alan Friedman
AUTOMATED BEARING WEAR DETECTION Alan Friedman DLI Engineering 253 Winslow Way W Bainbridge Island, WA 98110 PH (206)-842-7656 - FAX (206)-842-7667 info@dliengineering.com Published in Vibration Institute
More informationANALYSIS OF MACHINERY HEALTH CONSIDERING THE PARAMETERS OF VIBRATION IN A MULTI-FUNCTIONING ARRANGEMENT
Proceedings of the International Conference on Mechanical Engineeringand Renewable Energy 2017 (ICMERE2017) 18 20 December, 2017, Chittagong, Bangladesh ICMERE2017-PI-328 ANALYSIS OF MACHINERY HEALTH CONSIDERING
More informationPOWER HOUSE FD & ID FANS ANALYZING CONCRETE FOUNDATION RESONANCE. Ken Singleton
POWER HOUSE FD & ID FANS ANALYZING CONCRETE FOUNDATION RESONANCE Ken Singleton Manager KSC Consulting LLC, Bristol VA ksingleton@vibrationconsulting.com Bob McGinnis, P.E. McGinnis Engineering LLC, Kingsport
More informationInvestigation and Analysis of Chatter Vibration in Centerless Bar Turning Machine
Investigation and Analysis of Chatter Vibration in Centerless Bar Turning Machine M. Girish Kumar* Prakash Vinod 1 P V Shashikumar 2 Central Manufacturing Technology Institute, Bangalore 560022, E-mail:
More informationBL500 Series Brake Lathes Variable and Single Speed Combination Lathes. Change from servicing rotors to drums in seconds!
BL500 Series Brake Lathes Variable and Single Speed Combination Lathes Change from servicing rotors to drums in seconds! BL505 Combination Brake Lathe 11 9 10 1 4 2 BL505 shown with optional Digi-Cal Auto
More informationOn-line Flux Monitoring of Hydro-generator Rotor Windings
On-line Flux Monitoring of Hydro-generator Rotor Windings M. Sasic, S.R. Campbell, B. A. Lloyd Iris Power LP, Canada ABSTRACT On-line monitoring systems to assess the condition of generator stator windings,
More informationSCREW JACKS Operating Instructions
INS114EN.5 SCREW JACKS Operating Instructions Sweden Int +46 372 265 00 info@swedrive.se Vat.no SE556145631901 138-4551 1 Table of Contents 1. Health and Safety... 3 1.1. Notice about safety... 3 1.2.
More informationFrequency Response Analysis of Deep Groove Ball Bearing
Frequency Response Analysis of Deep Groove Ball Bearing K. Raghavendra 1, Karabasanagouda.B.N 2 1 Assistant Professor, Department of Mechanical Engineering, Bellary Institute of Technology & Management,
More informationThere s Still Value in Overall Vibration Measurements By John C. Johnson Balance Plus Wichita, Kansas
There s Still Value in Overall Vibration Measurements By John C. Johnson Balance Plus Wichita, Kansas John Johnson is owner of Balance Plus in Wichita, Kansas. He has over 29 years experience in maintenance
More informationCASE STUDY: Rotor Bar Fault in AC Induction
Dwight Bradshaw General Manager DBradshaw@VoyagerInstruments.com Office: 970.232.9344 Cell: 970.412.8264 VoyagerInstruments.com CASE STUDY: Pioneer Engineering is a leading engineering services company
More informationPulse Width Modulated Motor Drive Fault Detection Using Electrical Signature Analysis
Pulse Width Modulated Motor Drive Fault Detection Using Electrical Signature Analysis By ALL-TEST Pro, LLC & EMA Inc. Industry s use of Motor Drives for AC motors continues to grow and the Pulse-Width
More informationDetection of Wind Turbine Gear Tooth Defects Using Sideband Energy Ratio
Wind energy resource assessment and forecasting Detection of Wind Turbine Gear Tooth Defects Using Sideband Energy Ratio J. Hanna Lead Engineer/Technologist jesse.hanna@ge.com C. Hatch Principal Engineer/Technologist
More informationOverall vibration, severity levels and crest factor plus
Overall vibration, severity levels and crest factor plus By Dr. George Zusman, Director of Product Development, PCB Piezotronics and Glenn Gardner, Business Unit Manager, Fluke Corporation White Paper
More informationInvestigation of Magnetic Field and Radial Force Harmonics in a Hydrogenerator Connected to a Three-Level NPC Converter
Investigation of Magnetic Field and Radial Force Harmonics in a Hydrogenerator Connected to a Three-Level NPC Converter Mostafa Valavi, Arne Nysveen, and Roy Nilsen Department of Electric Power Engineering
More informationWhat are we looking at?
What are we looking at? What are our Goals: Accurate information to provide: Machinery Condition Monitoring Machinery Diagnostics Machinery Reliability Improvements Etc. Probe Coil Types 3000 and 7000
More informationRELIABILITY WEEKLY 2 MACHINE RESONANCE & VIBRATIONS
RELIABILITY WEEKLY 2 MACHINE RESONANCE & VIBRATIONS It's no secret that severe vibration can destroy bearings, ruin shafts and potentially disrupt production. What's less well known is that resonant machine
More informationStudy of Vee Plate Manufacturing Method for Indexing Table
Study of Vee Plate Manufacturing Method for Indexing Table Yeon Taek OH Department of Robot System Engineering, Tongmyong University 428 Sinseon-ro, Nam-gu, Busan, Korea yeonoh@tu.ac.kr Abstract The indexing
More informationElectrical Motor Power Measurement & Analysis
Electrical Motor Power Measurement & Analysis Understand the basics to drive greater efficiency Test&Measurement Energy is one of the highest cost items in a plant or facility, and motors often consume
More informationCONTINUOUS CONDITION MONITORING WITH VIBRATION TRANSMITTERS AND PLANT PLCS
SENSORS FOR MACHINERY HEALTH MONITORING WHITE PAPER #47 CONTINUOUS CONDITION MONITORING WITH VIBRATION TRANSMITTERS AND PLANT PLCS www.pcb.com/imi-sensors imi@pcb.com 800.828.8840 Continuous Condition
More informationKnowledge Is Power SM Apparatus Maintenance and Power Management for Energy Delivery. Application of EMI Diagnostics to Hydro Generators
Knowledge Is Power SM Apparatus Maintenance and Power Management for Energy Delivery Application of EMI Diagnostics to Hydro Generators James Timperley Doble Global Power Services Columbus, Ohio jtimperley@doble.com
More informationMotor Encoders. With Motor encoders Series M - Optimal control of motor feedback -
Motor Encoders With Motor encoders Series M - Optimal control of motor feedback - Hengstler supplies the new high-performance motor encoder series M for use with brushless servo motors and stepper motors.
More informationBenefits of Implementing a Basic Vibration Analysis Program for Power Transmission Drives
Benefits of Implementing a Basic Vibration Analysis Program for Power Condition monitoring Vibration analysis is a powerful tool that when integrated into an overall inspection program will help save maintenance
More informationNOISE REDUCTION IN SCREW COMPRESSORS BY THE CONTROL OF ROTOR TRANSMISSION ERROR
C145, Page 1 NOISE REDUCTION IN SCREW COMPRESSORS BY THE CONTROL OF ROTOR TRANSMISSION ERROR Dr. CHRISTOPHER S. HOLMES HOLROYD, Research & Development Department Rochdale, Lancashire, United Kingdom Email:
More informationChapter 2 High Speed Machining
Chapter 2 High Speed Machining 1 WHAT IS HIGH SPEED MACHINING (HSM)??? Low Speed High Speed 2 Defined as the use of higher spindle speeds and axis feed rates to achieve high material removal rates without
More informationVertical Shaft Plumbness Using a Laser Alignment System. By Daus Studenberg, Ludeca, Inc.
ABSTRACT Vertical Shaft Plumbness Using a Laser Alignment System By Daus Studenberg, Ludeca, Inc. Traditionally, plumbness measurements on a vertical hydro-turbine/generator shaft involved stringing a
More informationOn-line Hydrogenerator Rotor Winding Condition Assessment Using Flux Monitoring. S.R. Campbell, G.C. Stone, M. Krikorian, G.
On-line Hydrogenerator Rotor Winding Condition Assessment Using Flux Monitoring S.R. Campbell, G.C. Stone, M. Krikorian, G. Proulx, Jan Stein Abstract: On-line monitoring systems to assess the condition
More informationCND INCORPORATED Massillon, OH
Report on Vibratory Stress Relief Prepared by Bruce B. Klauba Product Group Manager CND INCORPORATED Massillon, OH 9500 HP FAN HOUSINGS Large distortion during separation of 9500 HP Fan Housing halves
More informationSIGNATURE ANALYSIS FOR ON-LINE MOTOR DIAGNOSTICS
Page 1 of 10 2015-PPIC-0187 SIGNATURE ANALYSIS FOR ON-LINE MOTOR DIAGNOSTICS Ian Culbert Senior Member, IEEE Qualitrol-Iris Power 3110 American Drive Mississauga, ON Canada Abstract - Stator current signature
More informationSeries Inline Oscillating Saw
Parts Manual Ersatzteil Liste 45-8185 12-2065 Series Inline Oscillating Saw IMPORTANT: Read and comply with safety and operating instructions contained in this manual. For additional product information
More informationApplication Note. GE Grid Solutions. Multilin 8 Series 869 Broken Rotor Bar Detection. Introduction
GE Grid Solutions Multilin 8 Series 869 Broken Rotor Bar Detection Application Note GE Publication Number: GET-20061 Copyright 2018 GE Multilin Inc. Introduction The Multilin 869 motor protection relay
More informationFixturlaser EVO. Fixturlaser EVO QUICK TIPS VibrAlign, Inc.
Fixturlaser EVO 2014 VibrAlign, Inc. QUICK TIPS PRE-ALIGNMENT 1. Rough Alignment Vertical: Place scale or straightedge on highest hub and raise or lower the movable shaft to within 20 mils (0.020 ) of
More informationMASTER ELECTRICAL SIGNATURE ANALYSIS (ESA) DEVELOPMENTS AT THE OAK RIDGE DIAGNOSTICS APPLIED RESEARCH CENTER. H. D. Haynes
ELECTRICAL SIGNATURE ANALYSIS (ESA) DEVELOPMENTS AT THE OAK RIDGE DIAGNOSTICS APPLIED RESEARCH CENTER H. D. Haynes Oak Ridge National Laboratory, Diagnostics Applied Research Center, Oak Ridge, Tennessee,
More informationn Measuring range ,02 N m to N m n Clockwise and counter-clockwise torque n Low linearity deviation of ± 0.05 % F.S.
Precision Torque Sensor Non-contact transmission for rotating applications Optional measurement of angle and speed Model 8661 Code: Delivery: Warranty: 2-3 weeks 24 months Application The 8661 precision
More informationWeeke Machining Center, Model BP-100 Optimat
This PDF file has not been verified for accuracy. BEFORE BIDDING, all bidders should use the inspection period to verify specifications. Weeke Machining Center, Model BP-100 Optimat Weeke's BP-100 is a
More informationFixturlaser XA. Fixturlaser XA QUICK TIPS VibrAlign, Inc.
Fixturlaser XA 2013 VibrAlign, Inc. QUICK TIPS PRE-ALIGNMENT 1. Rough Alignment Vertical: Place scale or straightedge on highest hub and raise or lower the movable shaft to within 20 mils (0.020 ) of the
More informationModule 4 General Purpose Machine Tools. Version 2 ME, IIT Kharagpur
Module 4 General urpose Machine Tools Lesson 24 Forces developing and acting in machine tools Instructional objectives At the end of this lesson, the students will be able to; (i) Identify the sources
More informationANALYTICAL NOISE MODELLING OF A CENTRIFUGAL FAN VALIDATED BY EXPERIMENTAL DATA
ANALYTICAL NOISE MODELLING OF A CENTRIFUGAL FAN VALIDATED BY EXPERIMENTAL DATA Beatrice Faverjon 1, Con Doolan 1, Danielle Moreau 1, Paul Croaker 1 and Nathan Kinkaid 1 1 School of Mechanical and Manufacturing
More informationcombine regular DC-motors with a gear-box and an encoder/potentiometer to form a position control loop can only assume a limited range of angular
Embedded Control Applications II MP10-1 Embedded Control Applications II MP10-2 week lecture topics 10 Embedded Control Applications II - Servo-motor control - Stepper motor control - The control of a
More informationBearing Wear Example #1 Inner Race Fault Alan Friedman DLI Engineering
Bearing Wear Example #1 Inner Race Fault Alan Friedman DLI Engineering The following spectrum comes from the motor end of a horizontally oriented centrifugal pump. The data was taken in the vertical axis.
More informationBL500 Series Brake Lathes
BL500 Series Brake Lathes Variable and Single Speed Combination Lathes Form 3937T, 04/04 Supersedes 3937T, 05/02 Change From Rotors to Drums in Seconds! BL505 Combination Brake Lathe 11 9 10 1 4 2 BL505
More informationVIBRATION DIAGNOSTICS AND OVERHAUL PROCEDURES IN HPP JAJCE 1
Presented at HydroVision July 28, 2016, Minneapolis, MN Ozren Husnjak, Research & Development, Veski Ltd, Croatia Ozren Oreskovic, Managing Director, Veski Ltd, Croatia Josip Mlinar, Project Manager, EP
More informationOptical Encoder Applications for Vibration Analysis
Optical Encoder Applications for Vibration Analysis Jack D. Peters Accelent Technology LLC 19 Olde Harbour Trail Rochester, New York, 14612 jack4accelent@aol.com Abstract: The application and use of an
More informationFault Diagnosis of an Induction Motor Using Motor Current Signature Analysis
Fault Diagnosis of an Induction Motor Using Motor Current Signature Analysis Swapnali Janrao and Prof. Mrs. Rupalee Ambekar Department of Electrical Engineering, BVP s College of Engineering (Deemed to
More informationResearch Article High Frequency Acceleration Envelope Power Spectrum for Fault Diagnosis on Journal Bearing using DEWESOFT
Research Journal of Applied Sciences, Engineering and Technology 8(10): 1225-1238, 2014 DOI:10.19026/rjaset.8.1088 ISSN: 2040-7459; e-issn: 2040-7467 2014 Maxwell Scientific Publication Corp. Submitted:
More informationFundamentals of Vibration Measurement and Analysis Explained
Fundamentals of Vibration Measurement and Analysis Explained Thanks to Peter Brown for this article. 1. Introduction: The advent of the microprocessor has enormously advanced the process of vibration data
More informationHigh Frequency/Precision Drives by Design
High Frequency/Precision Drives by Design SPINDEL Master is a line of universal high frequency drives, suited for operation of a wide range of phase AC motors, from standard low speed motors rated 50 or
More informationBearing Fault Diagnosis
Quick facts Bearing Fault Diagnosis Rolling element bearings keep our machines turning - or at least that is what we expect them to do - the sad reality however is that only 10% of rolling element bearings
More informationTheme 2 The Turbine Dr Geoff Dutton
SUPERGEN Wind Wind Energy Technology Phase 2 Theme 2 The Turbine Dr Geoff Dutton Supergen Wind Phase 2 General Assembly Meeting 21 March 2012 Normalized spectrum [db] Turbine blade materials The Turbine
More informationShaft Vibration Monitoring System for Rotating Machinery
2016 Sixth International Conference on Instrumentation & Measurement, Computer, Communication and Control Shaft Vibration Monitoring System for Rotating Machinery Zhang Guanglin School of Automation department,
More informationRotordynamics Analysis Overview
Rotordynamics Analysis Overview Featuring Analysis Capability of RAPPID Prepared by Rotordynamics-Seal Research Website: www.rda.guru Email: rsr@rda.guru Rotordynamics Analysis, Rotordynamics Transfer
More informationINDUCTION MOTOR FAULT DIAGNOSTICS USING FUZZY SYSTEM
INDUCTION MOTOR FAULT DIAGNOSTICS USING FUZZY SYSTEM L.Kanimozhi 1, Manimaran.R 2, T.Rajeshwaran 3, Surijith Bharathi.S 4 1,2,3,4 Department of Mechatronics Engineering, SNS College Technology, Coimbatore,
More informationRotary Position Technology Incremental Encoders
-40 to 80 C Temperature Shock/vibration resistant Short-circuit protected Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection
More informationTRIALLIANCE FABRICATING: Mertztown, PA Job #2
Report on Vibratory Stress Relief Prepared by Bruce B. Klauba Product Group Manager TRIALLIANCE FABRICATING: Mertztown, PA Job #2 TRIALLIANCE FABRICATING, a steel fabricator, subcontracted VSR Technology
More informationTRI-ALLIANCE FABRICATING Mertztown, PA Job #1
Report on Vibratory Stress Relief Prepared by Bruce B. Klauba Product Group Manager TRI-ALLIANCE FABRICATING Mertztown, PA Job #1 TRI-ALLIANCE FABRICATING subcontracted VSR TECHNOLOGY to stress relieve
More informationSVENSK STANDARD SS :2014
SVENSK STANDARD SS 728000-1:2014 Fastställd/Approved: 2014-06-30 Publicerad/Published: 2014-07-01 Utgåva/Edition: 1 Språk/Language: engelska/english ICS: 25.040.20 Spindlar för verktygsmaskiner Utvärdering
More informationCylindrical rotor inter-turn short-circuit detection
Cylindrical rotor inter-turn short-circuit detection by Kobus Stols, Eskom A strayflux probe is commonly used in the industry to determine if any inter-turn short-circuits are present in the field winding
More informationType XTSR71 Sizes
(Page 1 of 13) s 494-5258 Type XTSR71 s 494-5258 Figure 1 Thomas XTSR71 Coupling 1. General Information 1.1 Thomas Couplings are designed to provide a mechanical connection between the rotating shafts
More informationTroubleshooting accelerometer installations
Troubleshooting accelerometer installations Accelerometer based monitoring systems can be tested to verify proper installation and operation. Testing ensures data integrity and can identify most commonly
More informationSpectral Analysis of Misalignment in Machines Using Sideband Components of Broken Rotor Bar, Shorted Turns and Eccentricity
International Journal of Electrical & Computer Sciences IJECS-IJENS Vol:1 No:6 77 Spectral Analysis of Misalignment in Machines Using Sideband Components of Broken Rotor Bar, Shorted Turns and Eccentricity
More informationDetection of an Inner Race Defect Using PeakVue
Detection of an Inner Race Defect Using PeakVue By: Aubrey Green, Lead Analyst In early January of 2012, I assumed the responsibilities of the vibration analysis program at a customer s site that had been
More informationRotating Machinery Fault Diagnosis Techniques Envelope and Cepstrum Analyses
Rotating Machinery Fault Diagnosis Techniques Envelope and Cepstrum Analyses Spectra Quest, Inc. 8205 Hermitage Road, Richmond, VA 23228, USA Tel: (804) 261-3300 www.spectraquest.com October 2006 ABSTRACT
More informationOverview of condition monitoring and vibration transducers
Overview of condition monitoring and vibration transducers Emeritus Professor R. B. Randall School of Mechanical and Manufacturing Engineering Sydney 2052, Australia Machine Monitoring and Diagnostics
More informationClassification of Misalignment and Unbalance Faults Based on Vibration analysis and KNN Classifier
Classification of Misalignment and Unbalance Faults Based on Vibration analysis and KNN Classifier Ashkan Nejadpak, Student Member, IEEE, Cai Xia Yang*, Member, IEEE Mechanical Engineering Department,
More informationExercise 3. Doubly-Fed Induction Generators EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Doubly-fed induction generator operation
Exercise 3 Doubly-Fed Induction Generators EXERCISE OBJECTIVE hen you have completed this exercise, you will be familiar with the operation of three-phase wound-rotor induction machines used as doubly-fed
More informationSOUND SPECTRUM MEASUREMENTS IN DUCTED AXIAL FAN UNDER STALL CONDITIONS AT FREQUENCY RANGE FROM 9000 HZ TO 9600 HZ
Int. J. Mech. Eng. & Rob. Res. 2012 Manikandapirapu P K et al., 2012 Research Paper ISSN 2278 0149 www.ijmerr.com Vol. 1, No. 2, July 2012 2012 IJMERR. All Rights Reserved SOUND SPECTRUM MEASUREMENTS IN
More informationCopyright 2017 by Turbomachinery Laboratory, Texas A&M Engineering Experiment Station
HIGH FREQUENCY VIBRATIONS ON GEARS 46 TH TURBOMACHINERY & 33 RD PUMP SYMPOSIA Dietmar Sterns Head of Engineering, High Speed Gears RENK Aktiengesellschaft Augsburg, Germany Dr. Michael Elbs Manager of
More information