ANALOG INPUT/OUTPUT MODULES SPECIFICATIONS* Input resistance. From ± 10 mveff to ± 50 Veff (see ranges) AC input ZIN = 100 KΩ

Size: px
Start display at page:

Download "ANALOG INPUT/OUTPUT MODULES SPECIFICATIONS* Input resistance. From ± 10 mveff to ± 50 Veff (see ranges) AC input ZIN = 100 KΩ"

Transcription

1 ACM ANALOG INPUT/OUTPUT MODULES Analog Input/Output: - Modules - Voltage - Potentiometer - Current - RTDs and thermocouples - Strain gage - Accelerometer - ICP Freq => Voltage - RMS => DC - Etc. Plug and Play Easy identification with eight colours High accuracy ± 0,03 % FS typical Insulation 500 Vrms Protected Input/Output Narrow and wide band Fault detection High reliability Very low cost ACM series was developed to answer in a simple way to any type of sensors' conditioning. Simplicity of use is not to the detriment of measure quality because ACM modules integrates: - Galvanic insulation up to 500 Vrms - Inputs and Outputs protections - Metrological characteristics of class > 12 bits - 4th order low-pass filters - A defect output in case of abnormality on the signal ACM modules are presented in eight colors with a clear identification to facilitate their maintenance. ACM modules are mounted on a STB6x2 for a module 8 and a STB658 to form 16 conditioned inputs or outputs. Furthermore, ACM modules are very cost attractive. SPECIFICATIONS* INPUT MODULES DC VOLTAGE VERSION Input range Input protection Input resistance Linearity From 50 mv to 50 V FS (see ordering information) ± 100 V DC 1 MΩ ± 0,1% FS ± 0,03% FS RMS/DC MODULES (FIN = 1 KHZ) SINUS Input range Coupling Bandwidth From ± 10 mveff to ± 50 Veff (see ranges) AC input ZIN = 100 KΩ 40 Hz to 20 KHz (± 1 db) ± 0,2 % FS (FS to FS/20) APPLICATIONS Linearity Crest factor CURRENT VERSION ± 0,05 % FS (FS to FS/20) 3 max Input resistor input protection 0 20 ma ; 4 20 ma ; 0 40 ma ± 2 ma; ± 5 ma; ± 8 ma ; ± 10 ma ; ± 20 ma ; ± 40 ma 50 Ω 24 V max CONTACT: mail@adas.fr Tel.:

2 ACM - ANALOG INPUT/OUTPUT MODULES INPUT MODULES (MORE) THERMOCOUPLE VERSION s J, K, T, E, R, S Cold junction compensation t = 25 C : ± 2 C Compensation error Δ t = 10 C to 40 C : ± 1,5 C Warn up time 10 mn Open-loop detection Yes PLATINIUM SENSOR VERSION (RTD) 3 and 4 wires Injected current 1 ma Linearization (PT100) Yes α 1 = STRAIN GAGE SPECIFICATIONS Wiring Bridge Supply bridge 10,000 V / 30 ma Sensibility 10 mv / V Gain 100 ACCELERO ICP Supply Constant current 4 ma / 24 V Coupling AC Fc (LPF) = 0,1 Hz VIN ± 5 V FS FILTERING Low-pass Butterworth 4th order polynomial filter Cutoff frequency To be defined at order (refer to table) ANALOG OUTPUT TO THE SYSTEM Voltage ± 10 V FS Output impedance < 10 Ω Max. current 5 ma ± 0,03 % typ. FS (± 0,06 min) Stability 20 ppm/ C OUTPUT MODULES VOLTAGE VERSION Levels Output drive Output resistance 0 5 V ; 0 10 V ± 5 V ; ± 10 V 20 ma max 0,5 Ω CURRENT VERSION Levels Output compliance voltage 0 20 ma ; 4 20 ma; ± 20 ma ± 10 V min OTHER Linearity Noise Bandwidth Output setting time Stability Output enable control Output protection ±0,05 % span ±0,03 % span 20 μa p-p 3 KHz (- 3dB) 100 μs 20 ppm/ C Security 0 V or 0 ma Continuous short to ground WWW. ADAS.FR

3 ACM - ANALOG INPUT/OUTPUT MODULES COMMON SPECIFICATIONS ISOLATION I/O Rated IMR High- voltage breakdown 500 Vrms 140 db at 60 Kz LOGIC OUTPUTS Function Output Detection of out-of-range or loop error condition open collector, TTL compatible POWER SUPPLY Consumption 0,5 W typ. 1 W max PHYSICAL CHARACTERISTICS Size (H x W x D) Mounting 55 x 50 x 17 mm DB 25 TYPE ENVIRONMENT Operating temperature - 10 C to + 70 C Storage temperature - 20 C to + 85 C Relative humidity 90 % non condensing EUROPEAN STANDARDS CE Compliance (EMC - EN EN Class A) ROHS /95/EC ACCESSORIES: SHUNT R = 0,00. Ω ou R = 0,1 Ω (1% ; 50ppm / C) CURRENT TRANSDUCER SPECIFICATIONS ACCESSORY ORDER: STB/SHUNT/0.XX ** 10 = 10 A 20 = 20 A 50 = 50 A STB/LA55P/** WWW. ADAS.FR

4 COMMENT COMMANDER MODULE D'ENTREE? ACM /IN *** OU ACM/IN***/RMS FREQUENCE DE COUPURE STANDARD FREQUENCE DE COUPURE SPECIALE F1 = 10Hz F3 = 100Hz F5 = 1KHz F6 = 5KHz F7 = 10KHz F8 = 20KHz TENSION DC TENSION AC BOUCLE COURANT COURANT MOYEN COURANT ELEVE BIPOLAIRE RMS VB = ± 50V VF ± 200V BA = 0/20mA R = 50Ω VA = ± 20V VD ± 150V (0mA = -10V / 20 ma = + 10V) 10 10A V0 = ± 10V VC ± 100V BB = 4/20mA R = 50Ω 20 20A V1 = ± 5V VB = ± 50V (4mA = -10V / 20 ma = + 10V) 50 50A V2 = ± 2V VA = ± 20V BC = ± 20mA R = 50 Ω STB/DERIVATION (0,01Ω) STB/LA55P/** V3 = ± 1V V0 = ± 10V ( ± 20mA 10V) + + V1 = ± 5V BD = 4/20mA R = 50Ω module module V2 = ± 2V (4mA = 0V / 20mA = 10V) V3 = ± 1V BE = 0 / 40mA R = 25Ω DC DC V4 = ± 500mV (0mA = -10V ; 40mA = +10V) ACM/IN/V6 = ± 10A dc ACM/IN/LA55P/DC V5 = ± 200mV BF = ± 8mA R = 50Ω ACM/INV9 = ± 1A dc V6 = ± 100mV Ex : ACM/INV0/RMS ( ± 8mA ±10V) AC BG = ± 5mA ACM/INV6/RMS = ± 10A eff AC V7 = ± 50mV ( ± 5mA ±10V) ACM/INV9/RMS = ± 1A eff ACM/IN/LA55P/RMS V8 = ± 20mV Ex : ACM/INBC BP : 40Hz à 20KHz V9 = ± 10mV Ex : ACM/INV4 STB/DERIVATION (0,1Ω) DC ACM/IN/V6 = ± 1A dc POTENTIOMETRE RESISTANCE (4 fils) ACM/INV9 = ± 100mA dc VALIM POT = 5,00V Référence PE INJ AC P0 = 0 5V R13 1KΩ 100µA ACM/INV6/RMS = ± 1A eff P1 = 0 10V R14 10KΩ 10µA ACM/INV9/RMS = ± 100A eff R15 100KΩ 10µA Ex : ACM/INP0 Ex : ACM/IN R1X

5 COMMENT COMMANDER MODULE D'ENTREE? ACM /IN *** THERMOCOUPLES ( C) SONDE PLATINIUM PONT DE JAUGE FONCTIONS SPECIALES TYPE J TYPE K A31 ou A41 = - 50 / C A32 ou A42 Ex: ACM/ SG350 Ω Ex:ACM/INLM35 J2 = / k3 = / IN: +/- 100mV -50 / C J1 = / k2 = / B31 ou B41 = - 50 / C ALP: 10V ; Fc: 1 KHz ACM/INMPX5100 J0 = / k1 = / B32 ou B42 Silicium intégré k0 = / Capteur de pression C31 ou C41 = - 50 / C Frescale MPX5100 series TYPE T TYPE E C32 ou C42 T1 = / E2 = / D31 ou D41 = - 50 / C T0 = / E1 = / D32 ou D42 E0 = / L31 ou L41 = - 50 / + 50 C TYPE R TYPE S L32 ou L42 1 = α = 0,385 3 = 3 fils R1 = / S1 = / = α = 0,392 4 = 4 fils R0 = / S0 = / Ex. : ACM/INB41 Ex. : ACM/INE2 FREQUENCE COUPURE STANDARD Notes : F1 = 10Hz F3 = 100Hz F5 = 1KHz Les plages thermocouples données ci-dessus sont en valeurs positives PE. C'est aussi possible en valeurs négatives. Ex : K = - 6,458mV = C

6 COMMENT COMMANDER MODULE DE SORTIE? ACM/OUT ** ACM/OUT **- I Haute tension mode commun Version isolement galvanique TENSION COURANT VIN = ± 10V VB = ± 40V VA = ± 20V V0 = ± 10V V1 = ± 5V BA BB BC BD = 0/20mA RLm = 500Ω (- 10V = 0mA ; + 10V = 20mA) = 4/20mA RLm = 500Ω (- 10V = 4mA ; + 10V = 20mA) = ± 20mA RLm = 500Ω (-10V = - 20mA ; +10V = 20mA) = 4/20mA RLm = 500Ω (0V = 4mA ; 10V = 20mA) WB = WIDE BAND BE = 0 / 40mA RLm = 200Ω (-10V = 0mA ; +10V = 40mA) Ex : ACM/OUTVA-WB BF = ± 8mA RLm = 1000Ω ( -10V = - 8mA ; 10V = 8mA) Ex : ACM/OUTBC NB : RLm = R Loop max

DOCUMENTATION. The new XALIS 9000 integrates a 32 bits microprocessor offering some more of performance.

DOCUMENTATION. The new XALIS 9000 integrates a 32 bits microprocessor offering some more of performance. DOCUMENTATION The new integrates a 32 bits microprocessor offering some more of performance. XALIS is a new digital indicator range with 2 colors numerical and alphanumerical display designed to provide

More information

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc HSI Series Modules Selection Guide HSI Series Modules Single channel High bandwidth - for dynamic signals Isolation (all models Analog signal output (±5 V Single channel modularity For DEWETRON systems

More information

DRG-SC Series Signal Conditioners

DRG-SC Series Signal Conditioners DRG-SC Series Signal Conditioners DRG-SC Series 245 Basic unit Models Available for Thermocouples, RTDs, DC Voltage and Current, Frequency, Strain Gage Bridge, AC Voltage and Current Field Configurable

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) TEST & MEASUREMENT PRODUCT GROUP 600 East Greenwich Avenue West Warwick, RI 02893 Phone: 401-828-4000 Fax: 401-822-2430

More information

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Linearized 4-Wire RTD Input 5B35 FEATURES Single-channel signal conditioning module that Amplifies, Protects, Filters, and Isolates Analog Input. Isolates and protects a wide variety of four-wire

More information

SDM3045X Digital Multimeter. DataSheet

SDM3045X Digital Multimeter. DataSheet SDM3045X Digital Multimeter DataSheet-2016.06 User-friendly Design Product Overview SDM3045X is a 4½ digit digital (60000 count) multimeter incorporating a dual-display and is especially well suited for

More information

Economical Digital Indicators For Process and Electrical Measurement

Economical Digital Indicators For Process and Electrical Measurement Economical Digital Indicators For Process and Electrical Measurement DP18 Series Panel Punches Available DP18-P5, 4 to 20 ma input. DP18-EC, thermocouple input visit omega.com/thermocouple for thermocouples.

More information

USB-2404-UI Specifications

USB-2404-UI Specifications Specifications Document Revision 1.1, April, 2011 Copyright 2011, Measurement Computing Corporation All specifications are subject to change without notice. Typical for the range 0 to 60 C unless otherwise

More information

CONTA-ELECTRONICS. Converter Units

CONTA-ELECTRONICS. Converter Units CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to

More information

S200 I/O System Units

S200 I/O System Units S200 I/O System Units S200 I/O is a range of cost effective I/O units which are bus compatible with S200L I/O and can be mixed with them in any order on the same DIN rail. The S200 I/O System features

More information

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01% Transportable documenting multifunction calibrator with high accuracy 0.01% CALYS 1200 is the ideal solution to simultaneously simulate and measure with a high accuracy of 0.01%: voltage, current, resistance,

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large

More information

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME. 8 3-0 0 0 1-0 0 0 1 4 A EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC * SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE www.vtiinstruments.com RELIABLE DATA FIRST TIME EVERY

More information

ADAM 4000/4100 Series

ADAM 4000/4100 Series ADAM 4000/4100 Series Common Dimensions Communication RS-485 (2-wire) to host Speeds: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps (ADAM-4080, ADAM-4080D only support up to 38400 bps) Max. communication

More information

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4] Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website Make sure to visit our Website http://wwwseframfr Sefram Sefram SEFRAM A new family of thermal recorders 6 to 36 channels 6 to 36 analogue channels Measurement boards : - 6 isolated channels universal

More information

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications Sefram SEFRAM Make sure to visit our Website http://wwwseframfr A new family of paperless recorders 6 to 72 channels, to cover all your applications 6 to 72 analogue channels Measurement boards : - 6 isolated

More information

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Linearized Thermocouple Input 7B47 FEATURES Interfaces, amplifies and filters input voltages from a J, K, T, E, R, S, B or N-type thermocouple. Module provides a precision output of either +1

More information

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Thermocouple Input 7B37 FEATURES Interfaces, amplifies, and filters input voltages from a J, K, T, E, R, S, or B-type thermocouple. Module provides a precision output of either +1 V to +5 V or

More information

Modular Smart Interfaces

Modular Smart Interfaces Modular Smart Interfaces Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement Modular Smart Interfaces MSI Series Modular Smart Interfaces (MSI) bring an expanded

More information

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance Data Sheet Version 1.9 imc CANSAS-L-HCI8 High isolated module for the capture of temperature, voltage, current (20 ma) and resistance The imc CANSAS module (CANSAS-L-HCI8) enable measurement of low voltage

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright

More information

P5201 Universal Programmable Transmitters with Galvanic Isolation

P5201 Universal Programmable Transmitters with Galvanic Isolation Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to

More information

Chapter 6 Specifications

Chapter 6 Specifications Chapter 6 Specifications DC Characteristics Function Range [2] Test Current or Burden Voltage DC Voltage DC Current Resistance [6] 24 Hour [3] T CAL ±1 Accuracy Specifications: ± (% of reading + % of range)

More information

AKP-AKU DIGITAL PANEL METER

AKP-AKU DIGITAL PANEL METER DIGITAL PANEL METER AKP-AKU Isolated digital indicators AKP and AKU are designed to provide display and signals transmission solutions. Its unique programmation principle on front plate or by digital output

More information

Tel: (949) Fax: (949) IAA100 Product Manual

Tel: (949) Fax: (949) IAA100 Product Manual IAA100 Product Manual Table of Contents Default Settings... 3 Connections... 3 Standard Span & Zero Adjustment... 4 Shunt Readings... 5 Digitally Controlled Remote Shunt... 5 Switch Configurations... 6

More information

Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC

Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC Selection Guide PAD Series Modules Multi channel Low bandwidth - for static signals Isolation Digital output (RS-485) Exchangeable For DEWETRON systems with built-in DAQ rack Module # CH Input type Ranges

More information

Assembly. Front view. Parametrization interface. Power Bus

Assembly. Front view. Parametrization interface. Power Bus Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and

More information

SDM3045X Digital Multimeter. DataSheet

SDM3045X Digital Multimeter. DataSheet SDM3045X Digital Multimeter DataSheet-2018.12 User-friendly Design Product Overview SDM3045X is a 4½ digit digital (60000 count) multimeter incorporating a dual-display and is especially well suited for

More information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

Features EX1629. High-performance Remote Strain Gage Measurement Unit. Overview. 48 programmable channels in a single unit

Features EX1629. High-performance Remote Strain Gage Measurement Unit. Overview. 48 programmable channels in a single unit Overview The VXI Technology EX1629 Remote Strain Gage simplifies stress and fatigue testing of large mechanical structures such as airframes and launch vehicles. Ethernet control allows for remote operation

More information

CALYS 50. Field multifunction calibrator for basic use

CALYS 50. Field multifunction calibrator for basic use Field multifunction calibrator for basic use CALYS 50 field multifunction calibrator is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field

More information

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

C330 / C330X PC-Programmable Universal, 2-wire Transmitter C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and

More information

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function Datasheet SDM3065X Digital Multimeter Product Overview SDM3065X is a 6 ½ digit digital (2,200,000 count) multimeter incorporating a dual display and is especially well suited for the needs of high-precision,

More information

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M2XU MODEL: M2XU [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and

More information

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners DRLP Series U ±0.03% Accuracy (Typical) U ±0.01% Linearity U 1500Vrms Transformer Isolation and 240Vrms Field-Side Protection U Wide Loop

More information

ONEXIS AUTOMATIONS PVT LTD B-8, First Floor, Industrial Area, Sector - 64, NOIDA , U.P, India Ph:

ONEXIS AUTOMATIONS PVT LTD B-8, First Floor, Industrial Area, Sector - 64, NOIDA , U.P, India Ph: X A L I S XALIS is a new digital indicator range with 2 colors numerical and alphanumerical display designed to provide display and signals transmission solutions. XALIS disign allows exceptional performances

More information

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Frequency Input 5B45 / 5B46 FEATURES Isolated Frequency Input. Amplifies, Protects, Filters, and Isolates Analog Input. Generates an output of 0 to +5V proportional to input frequency. Model

More information

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase Introduction ISOLATD SIGNAL CONDITIONING can significantly increase your system reliability here's how: Linearizes Thermocouple and RTD signals Reduces the demands on the software to linearize the signal

More information

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Linearized RTD Input 7B34 FEATURES Amplifies, Protects, Filters, and interfaces input voltages from a wide variety of two and three-wire platinum, copper and nickel Resistor Temperature Detectors

More information

EX FEATURES. Stand-alone 48-channel unit with built-in Ethernet controller. Built-in bridge completion and Excitation

EX FEATURES. Stand-alone 48-channel unit with built-in Ethernet controller. Built-in bridge completion and Excitation data sheet EX1629-001 High-performance Remote Strain Gage Measurement Unit FEATURES Stand-alone 48-channel unit with built-in Ethernet controller Built-in bridge completion and Excitation 24-bit A/D per

More information

Analog Isolation Amplifiers

Analog Isolation Amplifiers Isolation Amplifiers Analog Isolation Amplifiers HSI/DAQ Series Modules DEWETRON high precision signal conditioning amplifiers are available for almost any sensor to measure Voltage Current Pressure Temperature

More information

SCM5B48 ACCELEROMETER INPUT MODULE USER S MANUAL

SCM5B48 ACCELEROMETER INPUT MODULE USER S MANUAL SCM5B48 ACCELEROMETER INPUT MODULE USER S MANUAL Section Description Page 1.0 Introduction 1 2.0 CE Compliance 1 3.0 Features and theory of operation 1 4.0 The High Pass filter and the Low Pass Bessel

More information

RS Pro DIGITAL MULTI-METER SDM3055 SERIES

RS Pro DIGITAL MULTI-METER SDM3055 SERIES ENGLISH Product Datasheet Stock No: 1236465 1236466 RS Pro DIGITAL MULTI-METER SDM3055 SERIES Product Overview RSDM3055 is a digital multimeter designed with 5 ½ digits readings resolution and dual-display,

More information

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

Ethernet-Based Temperature, Voltage and Strain Measurement Modules Ethernet-Based Temperature, Voltage and Strain Measurement Modules OMB-NET6000 Series OMB-NET6220 shown smaller than actual size. U 12 Analog Inputs U 8 Digital I/O U Simultaneous Sampling U Multiple Trigger

More information

DP2000 ORDERING GUIDE To Order MODEL NO.

DP2000 ORDERING GUIDE To Order MODEL NO. 1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition

More information

Q.raxx A101-8 slimline RS / EC

Q.raxx A101-8 slimline RS / EC The Q.raxx slimline product is based on the standardized 19 technology, one rack mount unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field

More information

MODEL: R30US4. Remote I/O R30 Series

MODEL: R30US4. Remote I/O R30 Series Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable

More information

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW Isolated, Linearized Thermocouple Input 5B47 FEATURES Isolated Thermocouple Input. Amplifies, Protects, Filters, and Isolates Thermocouple Input Works with J, K, T, E, R, S, and B-type thermocouple. Generates

More information

High-precision process calibrator Model CED7000

High-precision process calibrator Model CED7000 Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry

More information

SHIMADEN DIGITAL INDICATOR

SHIMADEN DIGITAL INDICATOR Shimaden, Temperature and Humidity Control Specialists C %RH Series SD24 & KR16A SHIMADEN DIGITAL INDICATOR BASIC FEATURES ohigh Accuracy ±0.1% FS+1 digit o1/1000ºc Resolution Indication Possible (Pt input

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels

More information

2 WIRE - LOOP POWERED AND ISOLATED TRANSMITTER FOR TERMORESISTANCE AND THERMOCOUPLE. resistances. The RTD input may be with 2,3 or 4 wire connection.

2 WIRE - LOOP POWERED AND ISOLATED TRANSMITTER FOR TERMORESISTANCE AND THERMOCOUPLE. resistances. The RTD input may be with 2,3 or 4 wire connection. EN T WIRE - LOOP POWERED AND ISOLATED TRANSMITTER FOR TERMORESISTANCE AND THERMOCOUPLE. GENERAL DESCRIPTION The T instrument converts and transmits the input read into a normalized signal current for..0

More information

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

USB-TEMP and TC Series USB-Based Temperature Measurement Devices USB-Based Temperature Measurement Devices Features Temperature and voltage measurement USB devices Thermocouple, RTD, thermistor, or semiconductor sensor measurements Eight analog inputs Up to ±10 V inputs*

More information

CALYS 100. Field precision documenting multifunction calibrator

CALYS 100. Field precision documenting multifunction calibrator Field precision documenting multifunction calibrator is a precision documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench

More information

FC-33, DC SELECTABLE SIGNAL CONDITIONER

FC-33, DC SELECTABLE SIGNAL CONDITIONER FC-33, DC SELECTABLE SIGNAL CONDITIONER Description. The FC-33 is a DIN rail or side mount, selectable input/output signal conditioner with 1500VDC isolation between input and output, and 1500VDC isolation

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 205-S ULTRASTAB I PN = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated High Level Voltage Output 7B22 FEATURES Unity gain single-channel signal conditioning output module. Interfaces and filters a +10 V input signal and provides an isolated precision output of +10V.

More information

Analog Signal Conditioning Accessories

Analog Signal Conditioning Accessories NI 64-channel multiplexer mv, V, current, and thermocouple inputs NI 8-channel simultaneous sample-and-hold mv, V inputs NI SC-2042-RTD 8-channel RTD/thermistor RTD, thermistor, mv, V inputs NI 8-channel

More information

minimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven)

minimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven) Digital panel meter 5-digit M2 red display of -19999 99999 digits (optional green, orange, blue or tricolour display) minimal installation depth: 70 mm without plug-in terminal adjustment via factory default

More information

CALYS 75. Field documenting multifunction calibrator

CALYS 75. Field documenting multifunction calibrator Field documenting multifunction calibrator is a field documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries.

More information

minimal installation depth: 57 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

minimal installation depth: 57 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting Digital panel meter 4-digit M1 red display of -1999 9999 digits (optional green, orange or blue display) minimal installation depth: 57 mm without plug-in terminal adjustment via factory default or directly

More information

ONE CALIBRATOR ONLY MAIN FEATURES:

ONE CALIBRATOR ONLY MAIN FEATURES: ONE CALIBRATOR ONLY The MEMOCAL 2000 is a lightweight versatile, portable, hand-held calibrator developed to solve two different and coexisting customer needs: field calibration (maintenance) and laboratory

More information

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter Shimaden, Temperature and Humidity Control Specialists C %RH CP3701: Thermocouple Temperature Converter CP3702: R.T.D. Temperature Converter CP3703: mv DC-DC Converter CP3704: V/mA DC-DC-Converter CP3705:

More information

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. Pinces Current ampèremetriques clamps for AC/DC pour current courant AC SERIE E N The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over

More information

8588A Reference Multimeter

8588A Reference Multimeter 8588A Reference Multimeter Product Specifications March 2019 Rev. A 2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of

More information

Q.raxx A slimline RS / EC Universal Measurement System

Q.raxx A slimline RS / EC Universal Measurement System Q.raxx A107-16 slimline RS / EC Universal Measurement System The Q.raxx slimline product is based on the standardised 19 technology, one rack unit (1 U) and is designed for measurements with a high level

More information

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4] Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking

More information

SDM3055 Digital Multimeter. DataSheet

SDM3055 Digital Multimeter. DataSheet SDM3055 Digital Multimeter DataSheet-2018.06 SDM3055 SDM3055-SC Product Overview The SDM3055/SDM3055-SC is a digital multimeter designed with 5 ½ digits readings resolution and dual-display, especially

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 200-S ULTRASTAB I PM = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)

More information

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS 150. Advanced documenting multifunction calibrator thermometer Advanced documenting multifunction calibrator thermometer, most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer

More information

SCXI 8-Channel Isolated Analog Input Modules

SCXI 8-Channel Isolated Analog Input Modules SCXI 8-Channel Isolated Analog Input NI, NI SCXI-1120, NI SCXI-1120D 8 channels 333 ks/s maximum sampling rate Gain and lowpass filter settings per channel Up to 300 V rms working isolation per channel

More information

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS 150. Advanced documenting multifunction calibrator thermometer Advanced documenting multifunction calibrator thermometer , most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer

More information

Temperature measurement TMD 832 head transmitter

Temperature measurement TMD 832 head transmitter Technical information TI 062R/09/en Mat.-Nr. 510 00782 Temperature measurement TMD 832 head transmitter SMART head transmitter with HART protocol for RTD, Thermocouple and mv input signals Applications

More information

SDM3055 Digital Multimeter. DataSheet

SDM3055 Digital Multimeter. DataSheet SDM3055 Digital Multimeter DataSheet-2017.06 SDM3055 Product Overview The SDM3055 is a digital multimeter designed with 5 ½ digits readings resolution and dual-display, especially fitting to the needs

More information

Q.raxx A slimline RS / EC

Q.raxx A slimline RS / EC The Q.raxx slimline product is based on the standardized 19 technology, one rack unit (1 U) and is designed for measurements with a high level of flexibility, reliability and accuracy in the field of stationary

More information

minimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

minimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting Digital panel meter 4-digit M1 red display of -1999 9999 digits (optional green, orange or blue display) minimal installation depth: 25 mm without plug-in terminal adjustment via factory default or directly

More information

WAVESERIES Signal converters

WAVESERIES Signal converters WAVESERIES Overview WAVESERIES Signal converters Isolation and conversion of analogue signals enclosed in a rail-mounted WAVEBOX housing WAVESERIES products are well suited for users seeking an analogue

More information

DIGEM f 96 x 48 EK. Applications. Description

DIGEM f 96 x 48 EK. Applications. Description 3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel

More information

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM104 SERIES SEM104P Pt100 Temperature Transmitter SEM104TC Thermocouple Temperature Transmitter SEM104P 1 1.0 DESCRIPTION 2 2.0 SPECIFICATION 2 3.0 INSTALLATION 24 4.0

More information

Analog Modules AS-i IP20

Analog Modules AS-i IP20 (Figure similar) Figure Type Inputs analog 4... 20 ma / 4... 20 ma / 4... 20 ma Pt100 4 x thermocouple type J 4 x thermocouple type K Outputs analog 0... 20 ma / 0... 20 ma / -10 V... +10 V Input voltage

More information

Datasheet ACT20M Signal Isolation and Conversion NEW

Datasheet ACT20M Signal Isolation and Conversion NEW Datasheet ACT0M Signal solation and Conversion NEW High quality signal isolation and conversion in a slim wide housing format is now available with Weidmuller s ACT0M range. Features include worldwide

More information

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels) Model:PFXLM4B01DDK PFXLM4B01DDC PFXLM4B01DAK PFXLM4B01DAC LT4000M Rear module Model Name Indication PFXLM4B01 D * * (1) (2) (3) (4) Notice to our valued customers who use LT4000M series (analog model)

More information

Temperature Transmitters - Head Mounted

Temperature Transmitters - Head Mounted XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction

More information

MEMOCAL 2000/2000S. Hand-held calibrator

MEMOCAL 2000/2000S. Hand-held calibrator MEMOCAL 2000/2000S Hand-held calibrator MEMOCAL 2000 Very low temperature drift (0.1µV/ C) Accuracy: 0.015% of span Power supply: standard AA size battery (Alkaline, NiCd or Ni-MH) Measurement & generation

More information

Industrial Interface The Signal Conditioning People

Industrial Interface The Signal Conditioning People Loop Powered Products including: 420TW 420i RTD/TC-HEAD Isolating Terminal Blocks Loop Powered Isolators In-Head Transmitters DC/AC Powered Isolation including: ISOCON DUALCON SLIMCON TC-TC VCON STRAIN

More information

PFXLM4B01 D * * (1) (2) (3) (4)

PFXLM4B01 D * * (1) (2) (3) (4) Model:PFXLM4B01DDK PFXLM4B01DDC PFXLM4B01DAK PFXLM4B01DAC LT4000M Rear module Model Name Indication PFXLM4B01 D * * (1) (2) (3) (4) Notice to our valued customers who use LT4000M series (analog model)

More information

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES PERFORMANCES High accuracy High stability Fast transients High inrush current facilities Wide bandwidth Very low distortion Quadrant change without transition Very low output impedance Low noise RS232

More information

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters The 520 transmitters are universal, isolated, dual-input temperature transmitters with additional voltage and resistance

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 605-S ULTRASTAB I PN = 600 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature

More information

General Specifications

General Specifications General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with

More information

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS 150. Advanced documenting multifunction calibrator thermometer Advanced documenting multifunction calibrator thermometer , most advanced documenting multifunction instrument of the range, works not only as a simulator (IN / OUT) but also as a dual channel thermometer

More information

s Climatix extension module 26 I/Os POL985.00/XXX

s Climatix extension module 26 I/Os POL985.00/XXX s 3 921 Climatix TM Climatix extension module 26 I/Os POL985.00/XXX The POL985.00/XXX extension module extends the number of I/Os of Climatix 600 controllers. It is a product of the Climatix range. The

More information

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions RIGOL Data Sheet Product Overview DM3058/DM3058E [1] is a digital multimeter designed with 5 ½ digits readings resolution and dual-display especially fitting to the needs of high-precision, multifunction

More information

MODEL: W2TS. Mini-MW Series

MODEL: W2TS. Mini-MW Series Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization

More information

Temperature Transmitter ZTT series

Temperature Transmitter ZTT series BT.11.13 ZT/I ZTT series The ZTT series transmitter accepts the most commonly used temperature sensors (RTD, T/C) as well as mv and slide wire signals. All the models adopt a 2 wire 4...20mA output signal

More information