TARAsens AS2 / AS3. Data Sheet. indicator
|
|
- Lucas Conley
- 6 years ago
- Views:
Transcription
1 TARAsens AS2 / AS3 indicator Application Chlorination agents appropriate chlorine dioxide production methods Measuring system Electronic Information about the measuring range of sensors with 4-20 ma Working temperature AS -CL: AS -CD: Free chlorine Chlorine dioxide drinking water cold, hot until max. 70 C inorganic chlorine compounds: NaOCl (=sodium hypochlorite), Ca(OCl) 2, chlorine gas, electrolytically generated chlorine e. g.: Acid/Chlorite-method Chlorine/Chlorite-method amperometric potentiostatic 3-electrode system Analog version: Digital version: ma-version: - voltage output - not galvanically isolated electronics - analog internal data processing - output signal: analog (analog-out/analog) - electronic is completely galvanically isolated - digital internal data processing - output signal: analog (analog-out/digital) or digital (digital-out/digital) - current output analog - not galvanically isolated electronics - output signal: analog (analog-out/analog) Slope of a sensor can vary production-related or application-related between 65% and 150% of the nominal slope -> Recommendation to determine the suitable measuring range or the suitable sensor: Concentration to be measured x factor 1.5 = measuring range of the sensor Example: Concentration to be measured 1.6 ppm x 1.5 = 2.4 -> recommended sensor with a measuring range of 5 ppm Measuring water temperature: AS2 : C AS3..: C (no ice crystals in the measuring water) Ambient temperature: C page 1 / 12
2 TARAsens AS2 / AS3 Temperature compensation Max. allowed working pressure Cleaning equipment RV1 Flow chamber Automatically, by an integrated temperature sensor Response time t 90 = approx. 10 min. Max. change in temperature: 30 C per hour, sudden temperature changes must be avoided Operation without retaining ring: 0.5 bar Operation with retaining ring: 8 bar Use is recommended for AS -CL (chlorine) Advantages: - significant extension of maintenance intervals - considerably more stable signal over long term TARAflow FLC (separate data sheet available) Flow rate : With RV1: min. 15 l/h, in TARAflow FLC l/h, in TARAflow FLC ph-range Run-in time Response time Zero point adjustment Slope calibration AS -CL: ph 5 ph 9, pay attention to the dissociation equilibrium HOCL (see diagram AS-sensors, relative dependence on ph, p. 11) AS -CD: ph 1 ph 12 or the beginning of decomposition of chlorine dioxide at/over ph 12 First start-up approx. 1 h up to 2 days, depending on the water quality T 90: approx. 30 sec. Not necessary Chlorine: At the device, by analytical determination, DPD-1-Method Chlorine dioxide: At the device, by analytical determination, (without chlorine) DPD-1-Method Interferences Absence of the disinfectant AS -CL: AS -CD: Max. 24 h Ozone, chlorine dioxide, chlorite are measured Chlorine, chlorite are measured with less than 2 % of their value analog-out/analog version: 4-pole plug adapter analog-out/digital version: 4-pole plug adapter digital-out/digital version: 5-pole M12, plug-on flange 4-20 ma version: 2-pole terminal or 5-pole M12, plug-on flange page 2 / 12
3 TARAsens AS2 / AS3 material Size AS2: AS3: PVC-U PEEK diameter: approx. 25 mm Length: analog-out/analog version approx. 175 mm analog-out/digital version approx. 195 mm digital-out/digital version approx. 205 mm 4-20 ma version approx. 220 mm (2-pole-terminal) approx. 190 mm (5-pole-M12) Transport C (Sensor, electrolyte) storage maintenance Sensor: - wet up to one year at C (filled with electrolyte and electrolyte-filled protection-cap) - only for AS2: dry no limit at C (without electrolyte) Electrolyte: in original bottle protected from sunlight at >+5 - <+35 C min. 1 year or until specified EXP-Date Regularly control of the measuring signal, min. once a week The following specifications depend on the water quality: Cleaning of the gold electrodes: without RV1 every 4 12 weeks every 6-12 months Change of the electrolyte: every 3-6 months Option: Factory service/maintenance (return the sensor to the manufacturer) EMV-Prüfung DIN EN , RoHS konform page 3 / 12
4 Cleaning equipment RV1-M Option direct installation on the sensor approaching flow to the sensor through RV1 cleaning effect of RV1 is moderate, i. e. weak deposits on the electrodes will be removed, e. g. weak rust films for a correct and proper operation of sensor with cleaning equipment RV1 flow chamber FLC-3 has to be used!! flow rate min. 45 l/h Sensor can be upgraded at any time Advice: Using with AS -CL: => slope is approx. 3 times higher (see diagram AS-Chlorine Sensor with and without RV1, p. 11) Using with AS -CD: => slope is approx. 2 times higher Accessories Component Art. No. Cleaning equipment RV1-M Cleaning equipment RV1 2 bags with each 3 cleaning balls emery S Spare Parts Type Hull Electrolyte Emery O-ring All AS2 All AS3 Hull AS2 Art. No Hull AS3 Art. No EAS1/GEL, 50 ml Art. No S3 Art. No x 1.5 silicone Art. no page 4 / 12
5 Technical Data A) Chlorine 1. AS CL (analog output, analog internal signal processing) analog-out / analog A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation. resolution Nominal slope (at ph 7.2) in mv/ppm Voltage AS2H-CL analog mv AS2N-CL kω AS2Up-CL analog mv 1 kω AS3H-CL analog mv AS3N-CL kω ±5 - ±15 VDC VDC ±5 - ±15 VDC 4-pole screw connector AS3Up-CL analog mv 1 kω VDC 2. AS CL (analog output, digital internal signal processing) analog-out / digital - The power is galvanically isolated inside of the sensor. - The output signal is galvanically isolated too, that means potential-free. Resolution Nominal Slope (at ph 7.2) Power Connectio n in mv/ppm AS2H-CL-An analog AS2N-CL-An V (max V) AS3H-CL-An k AS3N-CL-An AS2H-CL-Ap analog AS2N-CL-Ap V (max V) AS3H-CL-Ap k AS3N-CL-Ap VDC approx ma 4-pole screw connector page 5 / 12
6 3. AS CL (digital output, analog internal signal processing) digital-out / digital - The power is galvanically isolated inside of the sensor. - The output signal is galvanically isolated too, that means potential-free. Resolution Power AS2H-CL-M0c AS2N-CL-M0c AS3H-CL-M0c Modbus RTU There are no terminating resistors in the sensor VDC approx ma 5-pole M12 plug-on flange AS3N-CL-M0c AS CL 4-20 ma (analog output, analog internal signal processing) analog-out / analog A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation. 4.1 Electrical connection: 2 pole terminal clamp resolution Nominal slope (at ph 7.2) in ma/ppm Voltage AS2MA1-CL AS2MA2-CL AS2MA5-CL AS2MA10-CL AS2MA20-CL AS3MA1-CL ma uncalibrated AS3MA2-CL AS3MA5-CL VDC R L 50Ω R L 900Ω 2-pole terminal (2 x 1 mm²) Recommend ed: Round cable 4 mm 2 x 0.34 mm² AS3MA10-CL AS3MA20-CL page 6 / 12
7 4.2 Electrical connection: 5 pole M12 plug-on flange resolution Nominal slope (at ph 7.2) in ma/ppm Voltage Connectio n AS2MA1-CL-M AS2MA2-CL-M AS2MA5-CL-M AS2MA10-CL-M AS2MA20-CL-M12 AS3MA1-CL-M ma uncalibrated AS3MA2-CL-M VDC R L 50Ω R L 900Ω 5-pole M12 plugon flange Function of wires: PIN2: +U PIN3: -U AS3MA5-CL-M AS3MA10-CL-M AS3MA20-CL-M page 7 / 12
8 B) Chlorine Dioxide 1. AS CD (analog output, analog internal signal processing) analog-out / analog A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation. resolution Nominal slope in mv/ppm Voltage Connectio n AS2H-CD mv kω AS2N-CD AS2Up-CD mv 1 kω AS3H-CD mv kω AS3N-CD ±5 - ±15 VDC VDC ±5 - ±15 VDC 4-pole screw connector AS3Up-CD mv 1 kω VDC 2. AS CD (analog output, digital internal signal processing) analog-out / digital - The power is galvanically isolated inside of the sensor. - The output signal is galvanically isolated too, that means potential-free. Resolution Nominal Slope in mv/ppm Power AS2H-CD-An analog AS2N-CD-An V (max V) AS3H-CD-An k AS3N-CD-An AS2H-CD-Ap analog AS2N-CD-Ap V (max V) AS3H-CD-Ap k AS3N-CD-Ap VDC approx ma 4-pole screw connector page 8 / 12
9 3. AS CD (digital output, analog internal signal processing) digital-out / digital - The power is galvanically isolated inside of the sensor. - The output signal is galvanically isolated too, that means potential-free. Resolution Power AS2H-CD-M0c AS2N-CD-M0c AS3H-CD-M0c Modbus RTU There are no terminating resistors in the sensor VDC approx ma 5-pole M12 plug-on flange AS3N-CD-M0c AS CD 4-20 ma (analog output, analog internal signal processing) analog-out / analog A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation. 4.1 Electrical connection: 2 pole terminal clamp resolution Nominal slope in ma/ppm Voltage AS2MA1-CD AS2MA2-CD AS2MA5-CD AS3MA1-CD ma unkalibriert AS3MA2-CD AS3MA5-CD VDC R L 50Ω R L 900Ω 2-pole terminal (2 x 1 mm²) Recommended : Round cable 4 mm 2 x 0.34 mm² page 9 / 12
10 4.2 Electrical connection: 5 pole M12 plug-on flange resolution Nominal slope in ma/ppm Voltage Connectio n AS2MA1-CD-M AS2MA2-CD-M AS2MA5-CD-M12 AS3MA1-CD-M ma unkalibriert AS3MA2-CD-M VDC R L 50Ω R L 900Ω 5-pole M12 plug-on flange Function of wires: PIN2: +U PIN3: -U AS3MA5-CD-M Reiss GmbH Elektrochemische Messtechnik Eisleber Str. 5 D Weinheim Germany page 10 / 12
11 AS-Sensoren, relative ph-abhängigkeit AS-sensors, relative dependence on ph 250 Cl Steilheit / slope [%] (ph7 = 100 %) K:\Technik\Serienprodukt e_we\as\as2\1_05_01_ph_abhängigkeit ph-wert / ph-value page 11 / 12
12 Sensor AS2 / AS3 Abhängigkeit vom Durchfluß, Dependence on the flow rate 200 Durchflussarmatur, Flow Chamber: PEF1/E or ph-wert: 1_02_01_Durchfluss Sensor signal mv Durchflußmenge, Flow rate (Liter/hours) page 12 / 12
TARAline CS4. Data Sheet
TARAline CS4 indicator Application Chlorination agents Measuring system Electronic Information about the measuring range of sensors with 4-20 ma Accuracy after calibration at repeatability conditions (25
More informationTARAtec P9. Data Sheet
TARAtec P9 indicator Application system Electronic Information about the measuring of sensors with 4-20 ma Working temperature Temperature compensation Max. allowed working pressure Flow rate Peracetic
More informationExample: Concentration to be measured 1.6 ppm x 1.5 = 2.4 -> recommended sensor with a measuring range of 5 ppm. Ambient temperature: C
TARAtec P10 indicator Application system Electronic Information about the measuring of sensors with 4-20 ma Working temperature Temperature compensation Max. allowed working pressure Flow rate Peracetic
More informationMeasuring and Controlling Unit Multronic OC
Measuring and Controlling Unit Multronic OC One channel measuring and controlling unit for ph / conductivity / Chlorine measuring Automatic temperature compensation Measuring and control behaviour simultaneously
More informationOPTISYS CL 1100 Technical Datasheet
OPTISYS CL 1100 Technical Datasheet Free chlorine/chlorine dioxide/ozone measuring system Complete measuring system ready to use and easy to maintain High quality and precise gold electrodes for usage
More informationMeasuring and Controlling Unit Multronic
Measuring and Controlling Unit Multronic Modular system Up to 3 measurement variables with control functions in one housing Free combination of the measurement variables ph / Redox / temperature / conductivity
More informationDrinking water monitoring
Drinking water monitoring Ready-to-use systems for monitoring of quality relevant parameters in drinking water Pre-assembled Ready for use Flexible and multi-purpose Single-parameter Systems Single-parameter
More informationOPTISENS CL 1100 Technical Datasheet
OPTISENS CL 1100 Technical Datasheet Free chlorine/chlorine dioxide/ozone sensor High quality and precise gold electrodes for usage in water analysis Membrane-free sensor for a wide application range Low
More informationTechnical Information Memosens CCS50D
TI01353C/07/EN/01.17 71371622 Products Solutions Services Technical Information Memosens CCS50D Digital sensor with Memosens technology for determining chlorine dioxide Memosens CCS50D offers high-precision
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationOPERATING MANUAL. ba15358e03 09/2014 F 500 DIN, F 500 BNC F 800 DIN, F 800 BNC FLUORIDE SENSITIVE ELECTRODE
OPERATING MANUAL ba15358e03 09/2014 F 500 DIN, F 500 BNC F 800 DIN, F 800 BNC FLUORIDE SENSITIVE ELECTRODE F 500 / F 800 Note The latest version of the present operating manual can be found on the Internet
More informationWATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL
MicroChem Water Analysis System The MicroChem is a versatile multi-parameter instrument capable of being configured as a transmitter or PID controller. Specifically designed for drinking and wastewater
More informationOPTISENS ORP 8590 Technical Datasheet
OPTISENS ORP 8590 Technical Datasheet ORP sensor for water and wastewaster industry Large ceramic diaphragm and integrated Pt100 Special sensor design for all-purpose applications Low maintenance costs
More informationRosemount TM 498CL ph-independent Free Chlorine Sensor
498CL LIQ-PDS-498CL Product Data Sheet Rosemount TM 498CL ph-independent Free Chlorine Sensor Reliably measure free chlorine without worrying about ph The Rosemount TM 498CL is an amperometric sensor capable
More informationFlow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes
GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - Rotor Characteristics Applications
More informationOPTISENS PH 8100 Technical Datasheet
OPTISENS PH 8100 Technical Datasheet ph sensor High quality and precise glass sensor for usage in low conductivity media High temperature resistency Suitable for application in chemical industry The documentation
More informationMagnetic Inductive Flow Sensors VMI Series
Magnetic Inductive Flow Sensors VMI Series SIKA Dr.Siebert & Kühn GmbH & Co. KG Struthweg 7 9 34260 Kaufungen Germany.: +49 5605 803-0 Fax: +49 5605 803-54 e-mail: info@sika.net www.sika.net Magnetic Inductive
More informationdtrans Az 01 µp Indicator/Controller for analytical measurement
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 6003-0 Fax: 49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationRoline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL
Roline L1 Series Humidity - Temperature Transmitters INSTRUCTION MANUAL 20030314 CONTENTS Overview... 3 Operation... 5 Power supply... 5 Operating range and limits... 5 Temperature compensation of the
More informationType PLC Fitting. Valve for Continuous control. Diaphragm valve. Output
Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationInductive Conductivity Meter ILM
1 Product Information ILM-2 ILM-3 Inductive Conductivity Meter ILM f o o d Application / Specified Usage Authorizations Inductive measurement of the specific conductivity of liquid media in the range of
More informationProcess displays For standard signals, temperature, resistance measurement
Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions
More informationConductivity / Temperature Transmitter LMIT 09
Conductivity / Temperature Transmitter ONE unit for CIP applications, concentration monitoring and make-up Measurement value logging covering five decades of measurement ranges from 0-200 µs/cm to 0-2
More informationCondumax CLS21 and CLS21D
Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:
More informationOPTISENS PH ph sensor. Technical Datasheet
Technical Datasheet ph sensor High quality and precise glass sensor for usage in water and waste water analysis Special sensor design for harsh applications Low maintenance costs and a long life cycle
More informationGRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)
GRUNDFOS DATA BOOKLET Measuring amplifiers and controllers, preassembled systems Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP) Table of contents 1. Product introduction 3 measuring amplifier and controller
More informationCondumax CLS15 and CLS15D
Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationSILICon IrrADIAnCe SenSor
Measurement of Solar Silicon irradiance sensors (Si sensor) show a cost-effective, but rugged and reliable solution for the measurement of solar irradiance, especially for the monitoring of Photovoltaic
More informationDPS 100 DPS 100. Gauge- / Differential- / Absolute Pressure Transmitter
Gauge- / Differential- / Absolute Pressure Transmitter for very low starting at 0. mbar inductive sensor for use in industry and laboratory differential ranges from 0... 0. mbar up to 0... 000 mbar The
More information20 General technical data XI/ON
20 General technical data XI/ON General technical information General technical data XI/ON Potential isolation Ambient temperature Operating temperature Storage temperature Relative humidity Noxious gas
More informationScrew-in resistance thermometers with plug connector
Data Sheet 90.2004 Page 1/7 s with plug connector for temperatures from -50 to +300 C highly resistant to shock and vibration connector locked in for reliable contact, IP65 or IP69K protection available
More informationM1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL
M1 Series Humidity - Temperature Transmitter INSTRUCTION MANUAL 20031110 -2- CONTENTS Overview... 3 Operation... 4 Power supply... 4 Operating range and limits... 4 Temperature compensation of the humidity
More informationWALLACE & TIERNAN MULTI-FUNCTION-CONTROLLER MFC from version V:2.00
WALLACE & TIERNAN MULTI-FUNCTION-CONTROLLER from version V:2.00 INSTRUCTION MANUAL Please note Original manual! 2 WT.050.580.000.DE.IM.0714 Contents Contents 1. Introduction 5 1.1 Documentation 5 2. General
More informationOPTISENS PH 8390 Technical Datasheet
OPTISENS PH 8390 Technical Datasheet ph sensor for water and wastewater industry Large PTFE diaphragm and integrated Pt100 Robust sensor design for harsh applications Low maintenance costs and a long life
More informationDIGEM f 96 x 48 EK. Applications. Description
3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel
More informationminimal installation depth: 57 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting
Digital panel meter 4-digit M1 red display of -1999 9999 digits (optional green, orange or blue display) minimal installation depth: 57 mm without plug-in terminal adjustment via factory default or directly
More informationMagnetic Inductive Flow Sensors induq. Series VMI
Magnetic Inductive Flow Sensors induq Series VMI Free Flow! Compact - cost-effective - robust! The induq from SIKA is a trio of extremly compact, low cost, magnetic inductive fl ow sensors. This new product
More informationSMARTPAT PH 1590 Technical Datasheet
SMARTPAT PH 1590 Technical Datasheet Digital ph sensor for the water industry 2-wire loop powered sensor with integrated transmitter technology Special sensor design for all-purpose applications Low maintenance
More informationCOMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z
KOBO-RP Transmitter for ORP Model ARM-Z measuring monitoring analysing COMPACT-LINE Measuring range -1999 to +1999 mv Switchable from ORP to ph ph or mv/orp (Oxidation Reduction Potential) and temperature
More informationHigh-precision process calibrator Model CED7000
Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry
More informationJUMPFLEX 857 Series ma ma V. Signal Conditioning/Relay and Solid State Modules
JUMPFLEX Series Signal Conditioning/Relay and Solid State Modules...0 V 0...0 ma...0 ma JUMPFLEX Series Today s factory automation and process control applications require conversion, isolation, and transmission
More informationSeapoint Rhodamine Fluorometer
Seapoint Rhodamine Fluorometer User Manual Standard Version 6/00 Dimensions Open Configuration (no pump) 2.5" (6.4 cm) 6.6" (16.8 cm) 5.1" (13.0 cm) Pumped Configuration Figure 1. 1/2 Scale Drawing. Page
More informationIsolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated, Thermocouple Input 7B37 FEATURES Interfaces, amplifies, and filters input voltages from a J, K, T, E, R, S, or B-type thermocouple. Module provides a precision output of either +1 V to +5 V or
More informationIsolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated, Linearized Thermocouple Input 7B47 FEATURES Interfaces, amplifies and filters input voltages from a J, K, T, E, R, S, B or N-type thermocouple. Module provides a precision output of either +1
More informationIsolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationCondumax W CLS15 and CLS15D
Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationJUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor
sales@jumo.co.uk info.us@jumo.net Vorläufig V Page 1/8 JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor Cell constants K = 0.01 1.0 202922 Series for universal application, e.g.
More informationLINEAR POTENTIOMETER. LZW Series. Key-Features:
LINEAR POTENTIOMETER LZW Series Key-Features: Content: Technical Data...2 Technical Drawing...3 Signal Conditioner Squeezer...4 Electrical Connection...5 Accessories...5 Order Code...6 - Two models with
More informationminimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting
Digital panel meter 4-digit M1 red display of -1999 9999 digits (optional green, orange or blue display) minimal installation depth: 25 mm without plug-in terminal adjustment via factory default or directly
More informationInstruction Manual. TT1000 Tower Earth Tester. Rev 01
Instruction Manual TT1000 Tower Earth Tester Rev 01 Contents 1 Introduction... 3 2 Features... 3 3 Operation... 4 3.1 Test Lead Configuration... 5 3.2 Probe Integrity Test... 6 3.3 Impedance measurement...
More informationUser Manual. PolyGard ADT and ADT Electrochemical Ammonia Transmitter Serial No. AT April 2008
PolyGard ADT-0 and ADT6- Electrochemical Ammonia Transmitter Serial No. AT0-00 User Manual April 008 Page Intended for Use... Functional Description.... Control Mode.... Sensor... Mounting.... Mounting
More informationWhat is a WQSensor? Software Installation. Uninstalling WQSensors Software. NexSens Technology, Inc. TABLE OF CONTENTS
Revision 2.01 TABLE OF CONTENTS 1 Sensor Operation... 3 1.1 ph & Temperature Sensors... 3 1.1.1 WQ-pH ph & Temperature Sensor...3 1.1.2 Making ph Sensor Measurements...4 1.1.3 Maintenance and Care...7
More informationInductive conductivity transmitter JUMO CTI-Junior
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 (0) 661 60 03-7 25 Fax: +49 (0) 661 60 03-6 81 E-Mail: mail@jumo.net
More informationR24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY
Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the
More informationWind Transmitter First Class
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021310/07/06 Wind Transmitter First Class 4.3350.00.000 4.3350.10.000 ADOLF THIES GmbH & Co. KG Hauptstraße
More informationDSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters
Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and
More informationChlorine / Chlorine Dioxide Measurement liquisys M CCM 223 / 253
Technical Information TI 214C/24/ae Chlorine / Chlorine Dioxide Measurement liquisys M CCM 223 / 253 Analyzer for free chlorine and chlorine dioxide Liquisys M CCM 253 Benefits at a glance Chlorine analyzer
More informationFlow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes
GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Characteristics Applications System Evaluation connection Media pressure temperature
More informationMouth Pressure Meter Service Manual
Contents page Introduction 3 Operation 3 Mouth Pressure Meter Layout 4 Sealing Strip Position 5 Cleaning and Maintaining the Mouth Pressure Meter 5 Disassembling the Mouth Pressure Meter 6 Reassembling
More informationma. JUMPFLEX 857 Series. Transducers / Relay and Optocoupler Modules
0 0 ma 0 V...0 ma JUMPFLEX Series Transducers / Relay and Optocoupler Modules JUMPFLEX Series A Complete Product Line is Available, Bringing Each Signal into Shape. The perfect match of housing and electronics
More informationminimal installation depth: 70 mm without plug-in terminal 30 additional adjustable setpoints (parameter driven)
Digital panel meter 5-digit M2 red display of -19999 99999 digits (optional green, orange, blue or tricolour display) minimal installation depth: 70 mm without plug-in terminal adjustment via factory default
More informationSMARTPAT ORP 8510 Technical Datasheet
SMARTPAT ORP 8510 Technical Datasheet Digital ORP sensor for the water industry 2-wire loop powered sensor with integrated transmitter technology Offline calibration function Pure platinum electrode and
More informationJUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values
JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values k For measured temperatures from -30... +260 C or -200... +600 C k For mobile or stationary temperature measurement
More informationDissolvedOxygenMonitor
Call 800.959.0299 to speak with a sales representative or visit us on the web at www.analyticaltechnology.com DissolvedOxygenMonitor Model Q46D Dissolved Oxygen Monitoring is critical to stable operation
More informationDMS Insert Module MSR 282
DMS-EINSTECKMODUL MSR 282 DMS Insert Module MSR 282 This input module is used to measure the expanding or compression of strain gauges with a Wheatstone bridge. The module has two channels, each with a
More informationC4E NUMERICAL SENSOR User manual
C4E NUMERICAL SENSOR User manual Distributed & Supported By: Edaphic Scientific Pty Ltd www.edaphic.com.au info@edaphic.com.au Ph: 1300 430 928 1 Version 1.0 CONTENTS 1. GENERAL...3 2. CHARACTERISTICS...4
More informationCable transducer Analog output / redundant Measuring length absolute up to 5 m
Features Magnetic sensing method Resolution: 12 bit Interface analog 0...10 V / 0.. V /...20 ma Measuring length up to m Removable stickers for water outlet Teach inputs Extremely light thanks to housing
More informationHumidity Temperature Sensor TFG80 Duct version with Polyga measuring element
Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH D-71145 Bondorf. Germany D-07987 Mohlsdorf-Teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0. Fax +49 (0)7457-3758 Tel. +49(0)3661-62704-0.
More informationSC-4/M User manual 4-channel measuring amplifier
Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, ++49-8024-48737, Fax.++49-8024 -5532 - Germany Web: www.kmt-gmbh.com E-mail: info@kmt-gmbh.com SC-4/M User manual 4-channel measuring amplifier
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationP5201 Universal Programmable Transmitters with Galvanic Isolation
Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to
More informationTechnical Information Condumax CLS21D/CLS21
TI00085C/07/EN/14.14 71268310 Products Solutions Services Technical Information Condumax CLS21D/CLS21 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1.0 cm 1 Application
More informationT10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en
T10FS Torque Flange Data Sheet Special features Nominal (rated) torques: 100 NVm, 200 NVm, 500 NVm, 1 knvm, 2 knvm, 3 knvm, 5 knvm, 10 knvm Nominal speed from 12,000 rpm to 24,000 rpm Low rotor weights
More informationPlease enter the identity code of your device here!
Operating Instructions DULCOMETER D2C Part 2: Adjustment and Operation, Measured Variables ph/chlorine dioxide ProMinent D2C2-001-pH/CIO2-GB ph/clo 2 7.20 ph 0.45 ppm DULCOMETER STOP STAR T ph/clo 2 7.20
More informationGeneral Specifications
General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter
More informationIsolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated, Linearized RTD Input 7B34 FEATURES Amplifies, Protects, Filters, and interfaces input voltages from a wide variety of two and three-wire platinum, copper and nickel Resistor Temperature Detectors
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationConductivity Transmitter
Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants
More informationLOW COST SDI 2210, 2260 & 2266 HIGH PERFORMANCE SDI 2220 & 2276
LOW COST & HIGH PERFORMANCE 1-AXIS DC ACCELEROMETER MODULES Low Noise: 10 μg Hz Typical for ±2g Full Scale Versions -55 to +125 C Operating Temperature Range Flexible +8 to +32 VDC Power Excellent Long
More information1000TR. Instructions
1000TR ph Instructions CONTENTS 1. INTRODUCTION... 2 1.1 COMMON INTRODUCTION... 2 1.2 PARTS & ACCESSORIES... 2 2. INSTALLATION... 3 2.1 CASING... 3 2.2 MOUNTING... 3 2.3 ELECTRICAL INSTALLATION... 3 2.3.1
More informationMetal Finishing. W600 Series Controllers. Summary of Key Benefits
Metal Finishing W600 Series Controllers The W600 series provides reliable, flexible and powerful control for your electroless plating or etching process Summary of Key Benefits Large touchscreen display
More informationInductive Standard Displacement Transducers
WA Inductive Standard Displacement Transducers Special features - Available as displacement probe or with detachable plunger - Good thermal stability in the event of temperature gradients - Space saving,
More informationDigital ORP sensor for the water and wastewater industry
SMARTSENS ORP 1590 Technical Datasheet Digital ORP sensor for the water and wastewater industry 2-wire loop powered sensor with integrated transmitter technology Usable for aggressive media with offline
More informationBlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells
D-42607 Solingen Postfach 10 07 08 D-42659 Solingen Ritterstr. 87-89 Phone +49 212 81 40 45-46 Fax +49 212815500 e-mail: mail@juchheim-solingen.de Internet: www.juchheim-solingen.de Data Sheet 20.2922
More informationCondumax CLS15 and CLS15D
Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationInstruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output
www.cometsystem.com Instruction Manual T5140 T5141 T5145 Programmable transmitter of CO2 concentration with 4-20 ma output T5240 T5241 T5245 Programmable transmitter of CO2 concentration with 0-10 V output
More informationUser Manual. PolyGard ADTD Infrared Carbon Dioxide Transmitter Serial No. SM03_00X. October, 2011
PolyGard Infrared Carbon Dioxide Transmitter Serial No. SM0_00X User Manual October, 0 GAADTD6_E_0 Page Intended Use... Functional Description.... Control Mode.... Sensor... Installation.... Mounting Instructions....
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationUltra-Low Power Analog Sensor Module for Sulfur Dioxide
Ultra-Low Power Analog Sensor Module for Sulfur Dioxide BENEFITS 0 to 3 V Analog Signal Output Low Power Consumption < 45 µw Fast Response On-board Temperature Sensor Easy Sensor Replacement Standard 8-pin
More informationJUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature
Data Sheet 20272 Page /7 JUMO ecotrans Lf 0 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature Type 20272 Housing for DIN rail mounting (5 x 7.5 mm to DIN EN
More informationDatasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C
Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P - 4-20mA output, default range supplied 0-100 C ENGLISH The TX203P RTD in-head mounted temperature transmitter connects
More informationED701 General Industry Pressure Transmitter
ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationMaintenance: Check the measurement signal: regularly required once a month Calibration: typically 6 to 12 months after installation
The SMR digital transmitters have been developed especially for use in liquids for pressure, differential pressure, hydrostatic level and water quality measurement such as free chlorine, ph, ORP, temperature,
More informationR S / R 100ppb 0.1. Fig. 1: R S /R 0 as a function of gas concentration at 50% RH and 25 C.
MiCS-2610 O 3 Sensor This datasheet describes the use of the MiCS-2610 in ozone detection applications. The package and the mode of operation described in this document target the detection of the oxidising
More informationConex DIA-1, -2, -2Q. Measuring amplifiers and controllers, preassembled systems. One or two parameters (Cl 2, ClO 2, O 3, H 2 O 2, PAA, ph, ORP)
GRUNDFOS DATA BOOKLET Conex DIA-1, -2, -2Q Measuring amplifiers and controllers, preassembled systems One or two parameters (Cl 2, ClO 2, O 3, H 2 O 2, PAA, ph, ORP) Conex DIA-1, -2, -2Q Table of contents
More informationSafe Measurements in High-Voltage Environments CSM GmbH Computer-Systeme-Messtechnik
Safe Measurements in High-Voltage Environments < Computer-Systeme-Messtechnik Innovative Measurement and Data Technology Why Measurements are Important! Development and optimization of drive concepts for
More informationGRUNDFOS ALLDOS DATA BOOKLET DIP. Measuring amplifiers and controllers Preassembled systems 50/60 Hz
GRUNDFOS ALLDOS DATA BOOKLET Measuring amplifiers and controllers Preassembled systems 50/60 Hz Contents Product features measuring amplifiers and controllers 3 -A preassembled systems 3 Identification
More information