> Product category: > Function: > User profi le: > Frequency band: 100 KHz to 6 GHz. > Related standard: ECC/REC/(02)04, EN > Related software:
|
|
- Beryl Lamb
- 6 years ago
- Views:
Transcription
1 > INSITE Free > Product category: E field narrow band measurement system with spectrum analyzer > Function: Performs in situ spot measurements, locates measurement points on a map > User profi le: Regulation agencies, certification offices, municipalities, broadcast, PMR and mobile phone operators, installers, research laboratories, administrative bodies > Frequency band: 1 KHz to 6 GHz > Related standard: ECC/REC/(2)4, EN5383 > Related software: INSITE Free, INSITE Free/ANFR, ISSBA module (for mapping) > Compatible spectrum analyzer*: ANRITSU: MS2711A/D, MS2661B, S332D, MT8212B, MT822A, MS2721B, MT8222A; Rohde & Schwarz: FSH3/6; WILLTEK: 911/912; AGILENT: E7495B, ESA series, 856xEC series > Included instrumentation, accessories & software: 1 or 2 probes, switch box (with battery charger), probe holder, antenna and cable calibration reports, wooden tripod, CD Rom and dongle key for INSITE Free SW and cables > Related services: Installation support and training, probe calibration, extended warranty * Other analyzers can be added upon request 22 General Public SATIMO RF Safety/ EMF measurement 3.28
2 INSITE Free is a compact measurement system for narrow band analysis. The system is composed of a probe connected to a switch/amplification box. The system also requires a spectrum analyzer. These elements can be operated either manually or remotely through INSITE Free software. The SW enables the user to define his measurement scenarios, to analyze measurements, review the results graphically and to generate automatically reports into Excel format. The switch enables successive selections of the three measurement axes to obtain an isotropic result without changing the position of the probe. As it is equipped with an amplifier, the switch also improves the sensitivity of the system over the 1 KHz to 3 MHz frequency band. Associated with a GPS or with the GPS function of an analyzer and used with ISSBA module, INSITE Free allows the measured levels to be represented on a scanned map or on a Microsoft Map Point format. Description of the measurement chain RF link Spectrum analyzer Switch Probe Computer Measurement scenarios can be defined by the user to fit specific requirements ➊ INSITE Free SW is a fl exible tool that can be confi gured by the user to perform measurements and generate reports according to specifi c measurement protocols, in particular those recommended by ECC. ➋ In addition, for the French market, INSITE Free/ ANFR SW follows the protocol v2.1 of the French National Agency of Frequencies (ANFR) step by step. STEP 1: Choose hardware confi guration. In this fi rst phase, the user programs the measurement session according to his own hardware confi guration: spectrum analyzer, GPS, probe, cable, UMTS scanner and switch. For this purpose the probe, cable and switch calibration fi les are selected and loaded. INSITE Free works with all the most frequently used spectrum analyzers.* Spectrum analyzer without UMTS scanning ANRITSU: MS2711A/D, MS2661B, S332D, MT8212B, Rohde & Schwarz: FSH3/6 WILLTEK 911/912 AGILENT: ESA series, 856xEC series Spectrum analyzer with UMTS scanning ANRISTU: MT822A, MS2721B, MT8222A AGILENT: E7495B * drivers for additional analyzers can be developed upon request SATIMO RF Safety/ EMF measurement 3.28 General Public 23
3 STEP 2: Defi ne measurement scenario Once the hardware has been confi gured, the user can program the measurement scenarios: Choose frequency bands to be measured from a list or create user-defi ned bands. Defi ne the channels or specifi c carriers. Defi ne channel width. Choose attenuation mode. Choose analysis mode (peaks, TDMA or UMTS). Choose automatic or manual defi nition of RBW/VBW. TDMA Analysis CW Analysis W-CDMA Analysis Selection of BCCH for TDMA Analysis STEP 4: Visualize results. The results can be visualized with the following functions: Full scan or per frequency band. Zoom in with peak identifi cation threshold. 3 types of scale for a better high and low band visualization. Quick view of element s properties. STEP 3: Perform measurement analysis. The data collected for each band is presented on the main window of the software. Measurements corresponding to each of the three axes can be displayed in order to check the polarisation of the electric fi eld. Depending on the characteristics of the spectrum analyzer, the user can repeat the following analysis modes: CW Analysis: selection of peaks according to predefi ned threshold. TDMA analysis: extrapolation of the level that corresponds to BCCH. W-CDMA analysis: UMTS decoding (measurement and extrapolation of the CPICH value). The user can re-launch measurements using specifi c detection modes (positive peak, negative peak, sample ) and measurement modes (Max. hold, Min. hold, and average) available with the spectrum analyzer. Sessions are saved in XML and results can be exported into Excel. The results can be compared to the reference levels given by specifi c guidelines. Two guidelines are available by default: ICNIRP Safety Code 6 (Other reference levels can be added upon request). high performance isotropic probes to cover the 1 KHz to 6 GHz frequency ranges Two probes are available: one covers the 1 KHz - 3 GHz, the other 2 GHz - 6 GHz frequency range. Both probes are made of three orthogonal monopoles. The patented shape of each monopole optimizes the functioning and isotropy of the probe over the entire frequency range. 24 General Public SATIMO RF Safety/ EMF measurement 3.28
4 MECHANICAL 1 KHz - 3 GHz probe ELECTRICAL Dimension 46 mm Sensitivity at 9 MHz 1 mv/m (without cable) (Given for a spectrum analyzer sensitivity of -9 dbm) (Cable loss are taken into account) Weight 98 gr Max. E field/9 MHz 2 V/m RF cable length 2 m Isotropy at 9 MHz ± 1 db Connector 3N Isotropy at 18 MHz ± 1,7 db Protection IP 44 Conditions for use (temperature, humidity) -1 to 5 c, 85 % humidity Probe antenna factor Axial Isotropy at 9 MHz Antenna factor (db) Vertical Horizontal 45 F1 F2 F3 2 db/division Sensitivity without amplifier (1 KHz - 3 GHz) Sensitivity with amplifier (1 KHz - 3 MHz) E (mv/m) 1 E (mv/m) , Axial Isotropy with horizontal polarization Isotropy (+/- db) 3, 2,5 2, 1,5 1,, Isotropy (+/- db) 5, 4,5 4, 3,5 3, 2,5 2, 1,5 1,,5 Axial Isotropy with vertical polarization SATIMO RF Safety/ EMF measurement 3.28 General Public 25
5 MECHANICAL 2 GHz - 6 GHz probe ELECTRICAL Dimension 7 mm Sensitivity at 4 MHz 5 mv/m (without cable) (given for a spectrum analyzer sensitivity of -9 dbm) (Cable loss are taken into account) Weight 25 gr Max. E field 2 V/m RF cable length 2 m Axial Isotropy 3,6 GHz +/- 1,5 db Connector 3 N Axial Isotropy 5,6 GHz +/- 2,5 db Protection IP 44 Working conditions 1 to 5 c, 85 % humidity 2 GHz - 6 GHz probe antenna factor Axial Isotropy 3.6 GHz Antenna factor (db) PV PH 2 db/division F1 F2 F3 Sensitivity Axial Isotropy 5.6 GHz E (mv/m) PV PH 2 db/division 26 General Public SATIMO RF Safety/ EMF measurement 3.28
6 Perform isotropic measurements without changing the position of the probe INSITE Free System performs a measurement for each axis and over all predefined bands. The value measured on each axis is then converted into field value. For each Band One scan for each axis X Y Z Conversion in field value [E] (db V/m) = Pmes (dbm) 13 + loss + AF (db m-1) AF : Antenna Factor loss: cable loss, switch loss Isotropic value calculation [E TOT ] (V/m) = ( [Ex] 2 (V/m) + [Ey] 2 (V/m) + [Ez] 2 (V/m) ) 1/2 Switch box characteristics Dimensions 1 mm x 2 mm x 5 mm Frequency range 1 KHz 6 GHz Battery autonomy 4 hours Immunity 2 V/m Protection IP55 Frequency range amplifier 1 KHz 3 MHz N connections Output : 1 female Max power input for amplifier -3 dbm Input : 3 female Interface USB Amplifier gain 32 db Working conditions -1 to 5 C, 85% humidity Intermodulation dbm dbm Sketch of the switch Transmission loss db -2 AMPLI RF OUT BATTERY CONTROL POWER SUPPLY Port 1 Port 2 Port 3 SATIMO RF Safety/ EMF measurement 3.28 General Public 27
7 Antenna factor with or without amplifier Hardware requirements Antenna factor (db/m) 12 1 Computer Cable link* Operating system Memory Free space PC Pentium 5 MHz 3 USB Port Windows 98/2/XP** 256 MB RAM 2 MB free space on hard disc 8 6 *Serial port, Ethernet or GPIB may be necessary depending on the analyzer **Compatibility with Vista is undergoing validation Probe 1 Probe 2 Probe 3 Probe 1 Probe 2 Probe 3 Amplifier gain Gain (db) Port 1 Port 2 Port 3 28 General Public SATIMO RF Safety/ EMF measurement 3.28
INSITE Free. Main features. System Configuration. An E-field narrow band measurement system to define safety perimeter or perform site certification
INSITE Free An E-field narrow band measurement system to define safety perimeter or perform site certification + Compatible with most spectrum analyzers available on the market Tri-axial probes with excellent
More informationSRM-3000 Selective Radiation Meter
SRM-3000 Selective Radiation Meter Complete Solution for Selective Measurement of RF and Microwave Electromagnetic Fields Isotropic and Single-Axis Measurements from 100 khz to 3 GHz Excellent Immunity
More informationR&S TS-EMF EMF Measurement System Easy, frequency-selective measurement of EMF emissions
TS-EMF_dat_en_0758-2777-12_v0501.indd 1 Product Brochure 05.01 Test & Measurement R&S TS-EMF EMF Measurement System Easy, frequency-selective measurement of EMF emissions 11.04.2016 09:35:59 R&S TS-EMF
More informationContinuous, remote monitoring and logging of electromagnetic fields
NARDA EMF MONITORS AMB-8059 Continuous, remote monitoring and logging of electromagnetic fields Interchangeable probes from 10 Hz to 40 GHz for low frequency & high frequency applications Multi-band probes
More informationHandheld Spectrum Analyzer R&S FSH 3
Handheld Spectrum Analyzer R&S FSH 3 100 khz to 3 GHz Fifth Edition December 2003i Spectrum analysis anywhere, anytime The R&S FSH3 is the ideal spectrum analyzer for rapid, high-precision, cost-effective
More informationSpecification for Radiated susceptibility Test
1 of 11 General Information on Radiated susceptibility test Supported frequency Range : 20MHz to 6GHz Supported Field strength : 30V/m at 3 meter distance 100V/m at 1 meter distance 2 of 11 Signal generator
More informationHandheld Spectrum Analyzer R&S FSH3
Handheld Spectrum Analyzer R&S FSH3 100 khz to 3 GHz Fourth Edition July 2003i Spectrum analysis anywhere, anytime The R&S FSH3 is the ideal spectrum analyzer for rapid, high-precision, cost-effective
More information> StarLab. Multi-purpose Antenna Measurement Multi-protocol Antenna Development Linear Array Antenna Measurement OTA Testing
TECHNOLOGY Near-field / Spherical Near-field / Cylindrical SOLUTIONS FOR Multi-purpose Antenna Measurement Multi-protocol Antenna Development Linear Array Antenna Measurement OTA Testing 18 StarLab: a
More informationMA24104A. Inline High Power Sensor. True-RMS, 600 MHz to 4 GHz
Product Brochure MA24104A Inline High Power Sensor True-RMS, 600 MHz to 4 GHz A Standalone, Compact, and Highly Accurate Inline High Power Sensor for your RF Power Measurement Needs MA24104A at a Glance
More informationSpectrum & Power Measurements Using the E6474A Wireless Network Optimization Platform Application Note By Richard Komar
Spectrum & Power Measurements Using the E6474A Wireless Network Optimization Platform Application Note By Richard Komar Contents Introduction...1 Band Clearing...2 Using the spectrum analyzer for band
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) R3000 EMI TEST RECEIVERS Fully IF digital EMI Receivers family for measurement of electromagnetic interference from
More informationContinuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3
Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3 GHz Magnetic fields monitoring from 10 Hz to 5 khz Automatic
More informationApplication Note TS-EMF. System for RF Exposure Measurements. System Check with Tri-Axis Sensor (Isotropic Antenna)
Application Note TS-EMF System for RF Exposure Measurements (Isotropic Antenna) 1 Introduction The three axes of the Tri-Axis sensor (isotropic antenna) of the TS-EMF are switched to a single output via
More informationHandheld Spectrum Analyzer R&S FSH3
Handheld Spectrum Analyzer R&S FSH3 100 khz to 3 GHz Third Edition March 2003i Spectrum analysis anywhere, anytime The R&S FSH3 is the ideal spectrum analyzer for rapid, high-precision, cost-effective
More information4GHz / 6GHz Radiation Measurement System
4GHz / 6GHz Radiation Measurement System The MegiQ Radiation Measurement System (RMS) is a compact test system that performs 3-axis radiation pattern measurement in non-anechoic spaces. With a frequency
More informationContinuous, remote monitoring and logging of electromagnetic fields
MULTI-BAND EMF AREA MONITOR AMB-8057 Continuous, remote monitoring and logging of electromagnetic fields New "Out of the Box" solutions for easiest operation! see page 5/12 for details Discrimination of
More informationMANUAL. PCD - Precision Conical Dipole Antenna
MANUAL PCD - Precision Conical Dipole Antenna RF Engineering MANUAL Precision Conical Dipole Antenna 12.10.2009 Version 2.0 Notice Seibersdorf Labor GmbH reserves the right to make changes to any product
More informationFrequency selective monitoring and logging of environmental electromagnetic fields
FREQUENCY SELECTIVE EMF AREA MONITOR AMS-8060 Frequency selective monitoring and logging of environmental electromagnetic fields Up to 20 fully programmable frequency bands Real built-in spectrum analyser
More informationR&S FSH Handheld Spectrum Analyzer Where mobility counts
R&S FSH Handheld Spectrum Analyzer Where mobility counts Test & Measurement Product Brochure 01.00 R&S FSH Handheld Spectrum Analyzer At a glance The R&S FSH spectrum analyzer is rugged, handy and designed
More informationRESEARCH DEVELOPMENT AND TESTING NATIONAL INSTITUTE FOR ELECTRICAL ENGINEERING I C M E T CRAIOVA
RESEARCH DEVELOPMENT AND TESTING NATIONAL INSTITUTE FOR ELECTRICAL ENGINEERING I C M E T CRAIOVA DEPARTMENT LABORATORIES High Voltage Division - HVD Laboratory for SAR evaluation Bvd. Decebal No. 118,
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Electric and Magnetic Field Measurement For Isotropic Measurement of Magnetic and Electric Fields Evaluation of Field
More informationSpectrum Analyzer R&S FS300
Spectrum Analyzer R&S FS300 9 khz to 3 GHz The new product family from Rohde & Schwarz Professional test equipment for laboratory, service and production The R&S FS300 is a highly accurate spectrum analyzer
More informationAnalog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED
Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED www.analog.com www.hittite.com THIS PAGE INTENTIONALLY LEFT BLANK New Article Feature by Hittite Microwave
More informationR&S FSH4/8 Spectrum Analyzer Specifications
R&S FSH4/8 Spectrum Analyzer Specifications Test & Measurement Data Sheet 02.00 CONTENTS Specifications... 3 Frequency...3 Sweep time...3 Bandwidths...4 Level...4 Trigger functions...5 Inputs and outputs...6
More informationContinuous, remote monitoring and logging of electromagnetic fields
MULTI-BAND EMF AREA MONITOR AMB-8057 Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total emf values Electric field monitoring up to
More informationSelective measurement of high frequency electric and magnetic fields
Selective Radiation Meter SRM-3000 Selective measurement of high frequency electric and magnetic fields from long wave up to mobile radio frequencies (100 khz to 3 GHz) Isotropic (non-directional) measurement
More information& REACTIVE RCIED JAMMING
LIGHTNING THE NEW Hybrid Jammer Generation INTELLIGENT & REACTIVE RCIED JAMMING WE GUARANTEE FOR LARGEST JAMMING DISTANCES FIELD TESTS / DEMONSTRATIONS AVAILABLE The LIGHTNING is a hybrid jamming system
More informationFSH3 100 khz to 3 GHz FSH6 100 khz to 6 GHz First Edition May 2004i
Handheld Spectrum Analyzer FSH FSH3 100 khz to 3 GHz FSH6 100 khz to 6 GHz First Edition May 2004i Spectrum analysis anywhere, anytime on earth and in space The FSH is the ideal spectrum analyzer for rapid,
More informationSelective measurement of high frequency electric and magnetic fields
Selective Radiation Meter SRM-3000 Selective measurement of high frequency electric and magnetic fields from long wave up to mobile radio frequencies (100 khz to 3 GHz) Isotropic (non-directional) measurement
More informationAgilent ESA-E Series Spectrum Analyzer
Agilent ESA-E Series Spectrum Analyzer Configuration Guide This ESA configuration guide will help you determine which performance options, measurement personalities, accessories, and services to include
More informationNHT 3DL. The new landmark meter for electromagnetic safety. Percipere Aestimare et Inquirere
NHT 3DL The new landmark meter for electromagnetic safety Percipere Aestimare et Inquirere NHT 3DL The new reference meter for the European directive 2013/35/EU NHT 3DL is a brand-new electromagnetic field
More informationTable of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...
Table of Contents 1. GENERAL INFORMATION... 4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST... 4 1.2 RELATED SUBMITTAL(S) / GRANT (S)... 7 1.3 TEST METHODOLOGY... 7 1.4 EQUIPMENT MODIFICATIONS... 7
More informationProduct Introduction ML8720C. Area Tester ML8740B. Area Scanner
Product Introduction ML8720C Area Tester ML8740B Area Scanner ML8720C Area Tester and ML8740B Area Scanner Product Introduction Anritsu Corporation Version 1.00 Slide 1 Why use high-performance tester
More informationTSMU/TSMU-H Radio Network Analyzer
Version 04.00 TSMU/TSMU-H Radio Network Analyzer October 2007 Universal platform for drive testing and coverage measurements WCDMA PN scanning (bands I to IX) with BCH (SIB) decoder ( TSMU) GSM network
More informationHandheld Spectrum Analyzer R&S FSH khz to 3 GHz
Handheld Spectrum Analyzer R&S FSH3 100 khz to 3 GHz Spectrum analysis anywhere, anytime The R&S FSH3 is the ideal spectrum analyzer for rapid, high-precision, cost-effective signal investigations. It
More information2801 Multilock. Communications System Analyzer. Data Sheet. Boosting wireless efficiency
Data Sheet 2801 Multilock Communications System Analyzer Boosting wireless efficiency A real multi-talented instrument the Willtek 2801 Multilock The Willtek 2801 Multilock is a test instrument for multiple
More informationR&S FSC Spectrum Analyzer Specifications
R&S FSC Spectrum Analyzer Specifications year Data Sheet Version 03.00 CONTENTS Base unit... 3 Frequency... 3 Sweep time... 3 Bandwidths... 3 Level... 4 Trigger functions... 5 Tracking generator (model.13/.16
More informationEXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947
EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947 7.1 RF Power -- Pursuant to 47 CFR 2.947(c) Method of Conducted Output Power Measurement: Adaptation of TIA/EIA-603-A clause 2.2.1 for Pulsed Measurements
More informationRadio Network Analyzer TSMU/TSMU-H
Flyer Radio Network Analyzer TSMU/TSMU-H Universal platform for coverage measurements UMTS PN scanning (bands I to VI) with BCH (SIB) decoder ( TSMU) GSM network scanning (bands 850, 900 public/extended/rail,
More informationAgilent PNA Series RF Network Analyzers
Agilent PNA Series RF Network Analyzers Configuration Guide E8356A/E8801A/N3381A E8357A/E8802A/N3382A E8358A/E8803A/N3383A 300 khz to 3 GHz 300 khz to 6 GHz 300 khz to 9 GHz System configuration summary
More informationPHALANX INTELEGENT SAFETY SYSTEMS
IRJ-HYBRID Intelligent & Reactive RCIED JAMMING NEW Hybrid RCIED JAMMER INTELLIGENT & REACTIVE RADIO-CONTROLLED DESIGNED TO PREVENT IMPROVISED EXPLOSIVE DEVICES Prevent trigger devices from activating
More informationEMC-scanner. HRE-series. See it before you CE it!
EMC-scanner HRE-series See it before you CE it! Print Screen image of a scan measurement. Seeing high frequencies! Now you can SEE high frequency electro magnetic fields. The background There are high
More information802.16s SOFTWARE PLATFORM
General Software s 802.16s SOFTWARE PLATFORM Architecture Operation system Embedded Linux 1. MAC layer application running on ARM processor 2. PHY layer application running on DSP Application software
More informationRF test report AU01+W02
Customer: Kehlbergstrasse 109 8054 Graz Austria Tel.: +43 664 415 6260 RF test report 170186-AU01+W02 The test result refers exclusively to the tested model. This test report may not be copied or published
More informationReflectometer Series:
Reflectometer Series: R54, R60 & R140 Vector Network Analyzers Clarke & Severn Electronics Ph +612 9482 1944 Email sales@clarke.com.au BUY NOW - www.cseonline.com.au KEY FEATURES Patent: US 9,291,657 No
More informationEMI Pre-Compliance Testing Solution
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com EMI Pre-Compliance Testing Solution GW Instek introduces the latest and comprehensive
More information3250 Series Spectrum Analyzer
The most important thing we build is trust ADVANCED ELECTRONIC SOLUTIONS AVIATION SERVICES COMMUNICATIONS AND CONNECTIVITY MISSION SYSTEMS 3250 Series Spectrum Analyzer > Agenda Introduction
More informationPRODUCT CATALOG. RF Test. VIAVI Solutions. Antennas
PRODUCT CATALOG RF Test VIAVI Solutions Antennas Table of Contents Selection Table...2 Omni Antenna G700050353, G700050354, G700050355, G700050356, G700050357...3 Dual Band Omni Antenna G700050359... 5
More informationR3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation
R3477 Signal Analyzers Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation Frequency range: 9 khz to 13.5 GHz World
More informationModulated Wideband Power Amplifier
1 Introduction The modulated wideband power amplifier is designed in order to create an inexpensive signal source for immunity testing of electronic building blocks and products. It is designed to be driven
More informationFrequency range 100 khz to 3 GHz 100 khz to 6 GHz 10 MHz to 18 GHz Reference frequency. 2 ppm in addition 2 ppm/10 C. 0 Hz, 100 Hz to 3 GHz
Specifications Specifications apply under the following conditions: 15 minutes warm-up time at ambient temperature, specified environmental conditions met, and calibration cycle adhered to. Data without
More informationHMC-T2100B. Portable & Battery Operated! OBSOLETE PRODUCT. Portable Synthesized Signal Generator, 10 MHz to 20 GHz
Portable Synthesized Signal Generator, 10 MHz to 20 GHz Portable & Battery Operated! Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed
More informationEN / EN RADIO TEST REPORT. Shanghai Anviz Technology Co.Ltd Fingerprint & RFID Time Attendance Model No.: A300
Page 1 of 28 Report No.: T1861387 02 EN 300 330-1/ EN 300 330-2 RADIO TEST REPORT On Behalf of Shanghai Anviz Technology Co.Ltd Fingerprint & RFID Time Attendance Model No.: A300 Prepared for : Shanghai
More informationSpectrum Analyzer FSL
Specifications Version 02.00 Spectrum Analyzer FSL August 2005 Specifications Specifications Specifications apply under the following conditions: 15 minutes warm-up time at ambient temperature, specified
More informationLow Loss Combiner LLC-1900-IN DATA SHEET. Overview
DATA SHEET Combines Multiple Technologies onto a Single Feed Line Low Loss Combining Combining for Multiple Technologies (GSM/UMTS, UMTS/UMTS, UMTS/LTE, CDMA/LTE, etc.) Minimal or No Guard Band High Reliability
More informationAgilent ESA-L Series Spectrum Analyzers
Agilent ESA-L Series Spectrum Analyzers Data Sheet Available frequency ranges E4403B E4408B 9 khz to 1.5 GHz 9 khz to 3.0 GHz 9 khz to 26.5 GHz As the lowest cost ESA option, these basic analyzers are
More informationEMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009
EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009 Our trek started in a small laboratory over 25 years ago. Since then, we ve been focused on making EMC measurements easier and the measuring
More informationR&S EB500 Monitoring Receiver Specifications
Radiomonitoring & Radiolocation Data Sheet 01.02 R&S EB500 Monitoring Receiver Specifications CONTENTS Definitions... 3 Specifications... 4 Frequency...4 Linearity...4 Interference rejection...4 Noise
More informationHandheld Spectrum Analyzer FSH. FSH3 100 khz to 3 GHz FSH6 100 khz to 6 GHz
Handheld Spectrum Analyzer FSH FSH3 100 khz to 3 GHz FSH6 100 khz to 6 GHz Third Edition June 2006 Spectrum analysis anywhere, anytime on earth and in space The FSH is the ideal spectrum analyzer for rapid,
More informationMAGNETIC FIELD METER Operator s Manual
Edition 4.4 September 2011 MAGNETIC FIELD METER 3000 Operator s Manual The MFM 3000 is a professional magnetic field instrument To make the best use of the instrument we recommend that you read this manual
More informationGPS Time and Frequency Reference Receiver
$ GPS Time and Frequency Reference Receiver Symmetricom s 58540A GPS time and frequency reference receiver features: Eight-channel, parallel tracking GPS engine C/A Code, L1 Carrier GPS T-RAIM satellite
More informationMonitoring electric and magnetic fields
PERSONAL MONITOR DE Patent 19,726,138 US Patents 5,955,954 4,634,968 Monitoring electric and magnetic fields radiated by broadcast transmitters, mobile phone base stations and radar systems Wide frequency
More informationDSA800. No.1 RIGOL TECHNOLOGIES, INC.
No.1 DSA800 9 khz to 1.5 GHz Frequency Range Typical -135 dbm Displayed Average Noise Level (DANL) -80 dbc/hz @10 khz offset Phase Noise Total Amplitude Uncertainty
More informationTEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C
TEST REPORT For RFID READER/WRITER In conformity with FCC CFR 47 Part15 Subpart C Model: TR3XM-SD01 / TR3XM-SU01 / TR3XM-SN01 FCC ID: MK4TR3XM-SX01 Test Item: RFID READER/WRITER Report No: RY1203Z12R1
More informationSafety Test Solutions. SRM-3006 Selective Radiation Meter. Selective Radiation Meter
Safety Test Solutions SRM-3006 Selective Radiation Meter SRM-3006 Selective Radiation Meter Features The Selective Radiation Meter (SRM-3006) is our second generation, hand-held system for performing narrowband
More informationAbout the HDSDR software operations for the IC-R8600
About the HDSDR software operations for the IC-R8600 These instructions describe how to use the HDSDR software. Before reading this guide, please read How to use the IC-R8600 as an SDR receiver that can
More informationTECHNICAL SPECIFICATION FOR RF (TEST &MEASUREMENT) DEVICE
TECHNICAL SPECIFICATION FOR RF (TEST &MEASUREMENT) DEVICE Test and measuring device supports the following measurement functions: A- Cable and Antenna Analyzer, 2 MHz to 4 GHz. B- Spectrum Analyzer, 100
More informationActerna DSAM Product Family
Acterna DSAM Product Family Digital Service Activation Meters Quick-Start Guide DSAM-1500, -2500. -2600, -3500, 3600 Specifications DSAM-1500, -2500. -2600, -3500, 3600 Specifications Product Specifications
More informationTesT system for ConduCTed and radiated immunity
nsg 070 TesT system for ConduCTed and radiated immunity The, successor of the NSG 070, is a multifunctional EMC immunity test system. Its large frequency range from to G and its modular set-up using internal
More informationClampco Sistemi Via Corecian, n Basiliano (UD)
Via Corecian, n. 60 33031 Basiliano (UD) AP2000 AP3000 Biconical Antenna User manual AP2000 - AP3000 User Manual - Rev 6.1, August 2009 Page 1 of 17 Index 1. USER INSTRUCTIONS...3 1.1. General features...
More informationCompact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES
Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES Frequency range: 9 khz - 6.5 or 8.5 GHz Measured parameters: S11, S12, S21, S22 Wide output power adjustment range: -50 dbm to +5 dbm
More informationMAGNETIC FIELD METER Operator s Manual
Edition 3.1 2009-09-03 MAGNETIC FIELD METER 2000 Operator s Manual The MFM 2000 is a professional magnetic field instrument To make the best use of the instrument we recommend that you read this manual
More informationFCC PART 15C & RSS 247 TEST REPORT
FCC PART 15C & RSS 247 TEST REPORT No. I18N01184-WLAN for Spectralink Corp GSM Quad-band/UMTS five-band/lte/ca Mobile phone 9640 with Hardware Version: PIO Software Version: vf03 FCC ID: IYG96XX IC: 2128B-96XX
More informationHMC-T2220B. Portable & Battery Operated! Portable Synthesized Signal Generator, 10 MHz to 20 GHz. Instrumentation Product Support at
Portable, 10 MHz to 20 GHz Portable & Battery Operated! 78-250-3343 tel 78-250-3373 fax Battery Operated 20 GHz Signal Generator! The is a battery powered, portable test equipment solution designed to
More informationDL/N 70. Datalogger CUSTOMER BENEFITS
Datalogger DL/N 70 CUSTOMER BENEFITS Multi-parameter probe: pressure, temperature and conductivity Can be installed into 2'' piezoelectric tubes Inundation-resistant battery housing Available with miniature
More informationNor150 Sound Intensity Option Sound intensity probe Nor1290
Product Data Nor150 Sound Intensity Option Sound intensity probe Nor1290 Sound Power measurements in accordance with - ISO 9614 - ANSI S12.12 - ECMA 160 Noise Mapping Noise Source locations Innovative
More informationIdeal for high dynamic range measurements from compression to noise floor
USB/Ethernet Very Wideband Synthesized Signal Generator 5Ω -75 dbm to +14 dbm, 25 khz - 64 MHz The Big Deal Cost effective production test solution Power level resolution of.1 db Frequency resolution under.1
More informationELECTROSMOG METER INSTRUCTION MANUAL
ELECTROSMOG METER INSTRUCTION MANUAL MA AVG 2 Title CONTENTS Page 1. SAFET INFORMATION... 1 2. INTRODUCTION... 2 2-1 Fundamentals... 2 2-2 Application... 3 2-3 Features... 4 3. SPECIFICATIONS... 5 3-1
More informationExperimental Compliance Testing of Telephony Base Stations, Broadcast Stations, and General Mobile Transmitters
Experimental Compliance Testing of Telephony Base Stations, Broadcast Stations, and General Mobile Transmitters Sven Kühn Foundation for Research on Information Technologies in Society ETH Zurich, Switzerland
More informationSpectrum Analyzers 2680 Series Features & benefits
Data Sheet Features & benefits n Frequency range: 9 khz to 2.1 or 3.2 GHz n High Sensitivity -161 dbm/hz displayed average noise level (DANL) n Low phase noise of -98 dbc/hz @ 10 khz offset n Low level
More informationR&S ZVH Cable and Antenna Analyzer Where mobility counts
Test & Measurement Product Brochure 01.00 R&S ZVH Cable and Antenna Analyzer Where mobility counts R&S ZVH Cable and Antenna Analyzer At a glance The R&S ZVH cable and antenna analyzer is rugged, handy
More informationAgilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software
Test System Overview Agilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software Test System Overview The Agilent Technologies test system is designed to verify the performance of the
More informationSelective measurement of high frequency electromagnetic
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Selective Radiation Meter SRM-3006 Selective measurement of high frequency electromagnetic fields Complete, easy to
More informationDSA700 Series Spectrum Analyzer
DSA700 Series Spectrum Analyzer Product Features: All-Digital IF Technology Frequency Range from 100 khz up to 1 GHz Min. -155 dbm Displayed Average Noise Level (Typ.) Min.
More informationInstrument. Specifications OR34/35. SmartRouter. 2 to 8 Channels Multi-Analyzers. Controller Unit TECHNICAL SPECIFICATIONS
Instrument TECHNICAL SPECIFICATIONS Specifications OR34/35 2 to 8 Channels Multi-Analyzers SmartRouter Controller Unit Table of Content Table of Content... 2 General description... 3 Modules... 3 PC requirement...
More informationNemko-CCL, Inc West Alexander Street Salt Lake City, UT
Nemko-CCL, Inc. 1940 West Alexander Street Salt Lake City, UT 84119 801-972-6146 Test Report Declaration of Conformity Test Of: MICRO-RM2.4 Test Specifications: ETSI EN 300 328 v1.7.1 (2006-10) Test Report
More informationAntenna and Propagation
Antenna and Propagation This courseware product contains scholarly and technical information and is protected by copyright laws and international treaties. No part of this publication may be reproduced
More informationMonitoring electric and magnetic fields
PERSONAL MONITOR RadMan / RadMan XT DE Patent 19,726,138 US Patents 5,955,954 4,634,968 Monitoring electric and magnetic fields ranging from high frequency to microwaves Wide frequency monitoring from1
More information8370 Court Avenue, Suite B-1 Ellicott City, Maryland (410) FCC CERTIFICATION
IKUSI FCC INFORMATION RF Measurement Report Prepared by:: National Certification Laboratory 8370 Court Avenue, Suite B-1 Ellicott City, Maryland 21043 (410) 461-5548 IIn Supportt off:: FCC CERTIFICATION
More informationR&S ZVT Vector Network Analyzer Specifications
R&S ZVT Vector Network Analyzer Specifications Test & Measurement Data Sheet 08.00 CONTENTS Definitions... 3 Specifications... 4 Measurement range...4 Measurement speed...5 Measurement accuracy...6 Effective
More informationR&S ZVH Cable and Antenna Analyzer Specifications
Umschlag_ZVH_dat-sw_v0300.indd 1 Data Sheet 03.00 Test & Measurement R&S ZVH Cable and Antenna Analyzer Specifications 18.05.2011 11:30:50 CONTENTS Definitions... 3 Specifications of the R&S ZVH cable
More informationBecker Nachrichtentechnik GmbH Kapellenweg Asbach - Germany
High Dynamic 8 Way Combiner 100 khz... 4000 MHz, 50 Ω Features - wideband - high dynamic - without signal losses - low power consumption - high port- to- port isolation - compact 19, 1 U design Applications
More informationR&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay
year Product Brochure Version 0.00 R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE 80.ad and IEEE 80.ay NRPM_bro_en_607-4687-_v000.indd 8.0.09 5:59:08 R&S NRPM Over-the-Air (OTA)
More information87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.
20 Amplifiers 83020A microwave 875A microwave 8308A microwave 8307A microwave 83006A microwave 8705C preamplifier 8705B preamplifier 83050/5A microwave The Agilent 83006/07/08/020/050/05A test s offer
More informationSelective measurement of high frequency electromagnetic
Selective Radiation Meter SRM-3006 Selective measurement of high frequency electromagnetic fields Complete, easy to use test system, consisting of a base unit and measuring antennas, for non-directional
More informationEM-ISight Electromagnetic Scanning System. Since Page 1 of 6 Phone (613) Fax (613)
Since 1981 EM-ISight Electromagnetic Scanning System Page 1 of 6 EM-ISight ALSAS EM7 APREL Laboratories is a pioneer in the area of automated system solutions and is pleased to introduce EM-ISight which,
More informationMultiport Solutions for E5071C ENA RF Network Analyzers Using External Switches. Application Note
Multiport Solutions for E5071C ENA RF Network Analyzers Using External Switches Application Note Introduction The evolution of components and modules is unstoppable because of increasing requirements from
More informationYRS01 York Reference Source
York Reference Source York Reference Source The YRS01 is a multi-mode reference source capable of producing a broadband noise or comb output up to 1GHz. Selectable noise or comb output - Flexibility across
More informationSeries CCRT-33S/CRT-33S Internal 50Ω Termination DC 18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch
COAX SWITCHES Series CCRT-33S/CRT-33S PART NUMBER CCRT-33S CRT-33S DESCRIPTION Commercial Failsafe SPDT, DC-18GHz, Internal 50Ω Termination Elite Failsafe SPDT, DC-22GHz, Internal 50Ω Termination The CCRT-33S/CRT-33S
More informationFCC Part 22H & 24E Measurement and Test Report
FCC Part 22H & 24E Measurement and Test Report For Shenzhen Concox Information Technology Co., Ltd Floor 4th, Building B, Gaoxinqi Industrial Park, Liuxian 1st Road, District 67, Bao an, Shenzhen, China
More information