Nor150 Sound Intensity Option Sound intensity probe Nor1290

Size: px
Start display at page:

Download "Nor150 Sound Intensity Option Sound intensity probe Nor1290"

Transcription

1 Product Data Nor150 Sound Intensity Option Sound intensity probe Nor1290 Sound Power measurements in accordance with - ISO ANSI S ECMA 160 Noise Mapping Noise Source locations Innovative sound instrumentation

2 The Nor150 equipped with the sound intensity option and the Nor1290 probe kit is a powerful tool for all types of sound intensity measurements. Every effort has been made to make a robust and user-friendly solution capable of handling all kinds of measurement situations, from high-precision laboratory conditions to demanding and rough fi eld use. Current segment Warning for current segment Features Compliant to IEC Class 1 Full on-board support for ISO Unique phase correction allows measuring 25 Hz to 10 khz with 12 mm spacer Intuitive warning indicators Measurement-based suggestions for improving results Automatic measurement sequence Pause and back-erase with graphical display Full measurement edit support (segment exclusion, resize, retake) Add segment support Export to Nor850 mapping and reporting software Photo, text and voice annotation NorRemote app for smartphone remote control Support for ½ and ¼ microphones Current surface Warning for cursor position Negative values in opposite direction Sound pressure level Warnings for each band Sound intensity with direction Toggle between intensity and power To open the Warning panel Band might need attention Toggle numerical representation Change between scope, simple and advanced view 2

3 Intuitive user-interface With simplicity in mind, the Nor150 user interface is designed for easy and intuitive operation. The user is presented with only the key information needed to decide whether a measurement is successful or not. Full-text warnings and improvement suggestions provides the necessary detail without confusion. If full, in-depth graphical or tabular representation of fi eld indicators or difference functions is desired, the advanced view is readily available to the user. Presentations include analysis of extraneous noise, repeatability, uncertainty values and dynamic capability. Overload indicator Measurement storage state Current time or elapsed measurement time Battery status Help system Sound power calculation based on segment area Indicates that A-weighing is applied to the displayed spectrum Attention: Higher FpI than recommended by ISO Measurement not complient: Two optional scans had to large difference Warning window activated by the INFO button. Standard compromised Attention required Excluded band The warning codes available in Intensity mode 3

4 Advanced View Dynamic capability analysis shows the dynamic capability of the probe and instrument, along with the field indicator FpI from the current measurement The -view shows the difference between two orthogonal scans The Extranous Intensity view shows the F+/- indicator for the total surface Scope View Full overview of surface values and warnings, along with the total values Several segments in a surface. Warnings indicate problems, borders indicate if the segment is completly measured or excluded 4

5 Profi le time sets the resolution of the time-analysis graph Desired fi lter range. A-weightet spectrum is calculated from the range defi ned in Calculated total range Choose which standard to base measurement method and calculations on Select desired Segment scanning procedure. May be changed during a project Select desired Accuracy. May be changed during a project The total range is the frequency range of which the networks are calculated from. May be changed during a project A menu for excluding bands if needed. May be changed during a project 5

6 A smart probe The Nor1290 probe kit offers a lightweight and rugged solution in demanding environments. The probe is equipped with a smartphone, providing single hand operation and the same measurement displays as on the Nor150. The system is fully synced, allowing the user to exploit several probe confi gurations in the same measurement situation. Specifications Sound Intensity Probe Nor1290 Frequency range (±2 db) Ref. IEC Class 1 Dynamic range lower limit (microphone thermal noise) db(a) 27 Dynamic range upper limit db 146 Nominal 250 Hz (±2 db) Microphone type Preamplifi er mv/pa 12.5 ½ Rear vented, Prepolarised ¼, IEPE powered Temperature range, operation C / F 5 to 40 / 41 to 104 Temperature coeffi cient db/ C Hz db/ F / Humidity range non condensing % RH Humidity coeffi Hz db/% RH Infl uence of axial vibration db re m/s² µpa 66 Spacers included mm 12, 25, 50, 100 Cable length m / feet 3 / 10 Connector type 7pin Lemo CE/RoHS compliant/ WEEE registered Yes/Yes/Yes The Nor150/Nor1290 kit 6

7 Performance Using our unique phase correction system, the Nor150 Sound Intensity Option is capable of measuring intensity with extremely high dynamic capability. The Nor1290 probe confi g- ured with the default 12 mm spacer will typically have better dynamic capability than required by the IEC for a 100 mm spacer. This is achieved using an advanced two-stage phase calibration system and the accompanying Nor1294 Phase Calibration Coupler. The fi rst stage in the correction process includes a phase correcting fi lter for each channel, directly targeting the error introduced by the ventilation on intensity probes. The Nor1294 enables calibration at very low frequencies, thus obtaining a high precision correction. The second stage involves a per-band calibration. Using a deterministic log-swept sine, the complete process time is dramatically reduced compared to pink-noise excitation. To prove compliance to the standard and persistent performance, all calibration data is stored in the Nor150, and may easily be presented at a later time. Nor1294 Phase Calibration Coupler The two-stage calibration process with additional verification saves considerable time compared to traditional methods Calibration history for each probe Dynamic Capability [db] Typical performance: Nor150 with Nor mm IEC Class 1 instrument 100 mm IEC Class 1 instrument 12 mm k 1.6k 2.5k 4k 6.3k 10k The Nor150/Nor1290 kit provides a dynamic capability never seen before 7

8 Flexibility The Nor150 supports advanced measurement surface editing. Segments may be excluded, resized or even substituted, both before a project is complete, and after. Reconfiguring the grade of accuracy is easy. This may be done either before, during or after the measurement process. Including and excluding frequency bands is just as easy. All segments are recalculated immediately. An important feature is the ability to pause the measurement during a scan if unwanted noise occurs. Using the dedicated Pause/Continue button, a time display shows a time graph and allows a chosen number of seconds to be removed from the measurement before proceeding with the scan. Full overview Although the Nor150 shows all measurement data as clearly and neat, the user may later want to analyse the measurement and generate reports on a computer. The Nor850 sound intensity software tool is designed for this purpose. The Pause display allows a chosen number of seconds to be removed from the measurement All the familiar views from the Nor150 is available in the Nor850. In addition, advanced 2D- and 3D-renderings of the measurement surface is available, which gives the user unique insight about the sound field. Advanced measurement analysis in the Nor850 software tool. Distributor: info@norsonic.com PD 1290 Ed2Rv1En 1016

Nor150 Sound Intensity Option Sound intensity probe Nor1290

Nor150 Sound Intensity Option Sound intensity probe Nor1290 Product Data Nor150 Sound Intensity Option Sound intensity probe Nor1290 Sound Power measurements in accordance with - ISO 9614 - ANSI S12.12 - ECMA 160 Noise Mapping Noise Source locations Innovative

More information

G.R.A.S. Sound & Vibration

G.R.A.S. Sound & Vibration Instruction Manual Sound-intensity Calibrator Type 51AB G.R.A.S. Sound & Vibration Skovlytoften 33, 2840 Holte, Denmark Tel. +45 45 66 40 46 Fax +45 45 66 40 47 Sound-intensity Calibrator Type 51AB Revision

More information

GRAS 40BD-FV 1/4" Prepolarized Pressure Microphone, Front Vented

GRAS 40BD-FV 1/4 Prepolarized Pressure Microphone, Front Vented GRAS 40BD-FV 1/4" Prepolarized Pressure Microphone, Front Vented Freq range: 4 Hz to 70 khz Dyn range: 44 db(a) to 174 db Sensitivity: 1.6 mv/pa The 40BD-FV is an IEC 61094 WS3P ¼" prepolarized pressure

More information

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 including Sound Intensity Microphone Pair Type 4197 and Dual Preamplifier Type 2683

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 including Sound Intensity Microphone Pair Type 4197 and Dual Preamplifier Type 2683 PRODUCT DATA Sound Intensity Probe Kit Type 3599 including Sound Intensity Microphone Pair Type 4197 and Dual Preamplifier Type 2683 Type 3599 is a two-microphone probe kit for measuring sound intensity.

More information

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features PRODUCT DATA Sound Intensity Calibrator Type 4297 Sound Intensity Calibrator Type 4297 is used for on site sound pressure calibration and pressure residual intensity index verification. Its most important

More information

nor140 SOUND ANALYSER

nor140 SOUND ANALYSER nor140 SOUND ANALYSER Applications: Environmental noise Sound recording Building acoustics Noise source identification Industrial hygiene Product development Quality control Sound power Speech intelligibility

More information

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683 PRODUCT DATA Probe Kit Type 3599 Microphone Pair Type 4197 Dual Preamplifier Type 2683 Type 3599 is a two-microphone probe kit for measuring sound intensity. Specially designed for use with Brüel & Kjær

More information

Noise Excitation Equipment for Building Acoustics Measurements Loudspeaker Systems Nor275 and Nor276 Power Amplifier Nor280 Tapping Machine Nor277

Noise Excitation Equipment for Building Acoustics Measurements Loudspeaker Systems Nor275 and Nor276 Power Amplifier Nor280 Tapping Machine Nor277 Product Data Noise Excitation Equipment for Building Acoustics Measurements Loudspeaker Systems Nor275 and Nor276 Power Amplifier Nor280 Tapping Machine Nor277 Norsonic is a leading supplier of noise excitation

More information

SC101. Class 1 integrating sound level meter with measurement. Applications Includes measurement protocols for: Noise generated by motor vehicles

SC101. Class 1 integrating sound level meter with measurement. Applications Includes measurement protocols for: Noise generated by motor vehicles Class 1 integrating sound level meter with measurement protocols Applications Includes measurement protocols for: MEASURING NOISE HAS NEVER BEEN SO EASY Noise generated by motor vehicles D_SC101_v0015_20120703_ENG

More information

Technical Documentation

Technical Documentation Technical Documentation Microphone Type 4964 for Hand-held Analyzer Types 2250, 2250-L and 2270 Supplement to Instruction Manual BE 1712 English BE 1864 11 Microphone Type 4964 for Hand-held Analyzer

More information

Real time spectrum analyser sound level meters

Real time spectrum analyser sound level meters Real time spectrum analyser sound level meters SC310 Class 1 analyser (1/1 + 1/3 + FFT) The SC310 analyser is the definitive solution for professionals in acoustics who need a precision, high performance,

More information

PRODUCT DATA. Sound Intensity Probe Kit for 2260 Type 3595 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683

PRODUCT DATA. Sound Intensity Probe Kit for 2260 Type 3595 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683 PRODUCT DATA Sound Intensity Probe Kit for 2260 Type 3595 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683 Type 3595 is a two-microphone probe kit for measuring sound intensity. Specially

More information

Vibration Transducer Calibration System

Vibration Transducer Calibration System 1 Overview UCON is designed for calibrating sensitivity, frequency response characteristic and amplitude linearity of acceleration transducer. There are three basic operation modes for the calibration

More information

NoiseMeters. Integrating Sound Level Meters Effective Solutions For Industrial Noise Management

NoiseMeters. Integrating Sound Level Meters Effective Solutions For Industrial Noise Management Integrating Sound Level Meters Effective Solutions For Industrial Noise Management The most simple to use, cost effective, compliant instruments of their kind Ideal for quick, accurate measurements to

More information

PRODUCT DATA. Sound Intensity Calibrator Type 4297

PRODUCT DATA. Sound Intensity Calibrator Type 4297 PRODUCT DATA Sound Intensity Calibrator Type 4297 Sound Intensity Calibrator Type 4297 is used for on-site sound-pressure calibration and pressure-residual intensity-index verification. Its most important

More information

nor131 nor132 INSTRUCTION MANUAL INSTRUMENT SOFWARE 3.1

nor131 nor132 INSTRUCTION MANUAL INSTRUMENT SOFWARE 3.1 INSTRUCTION MANUAL INSTRUMENT SOFWARE 3.1 Nor131 is a versatile IEC Class 1 sound level meter. The combination of only one large measurement range with a lot of parameters measured in parallel makes the

More information

Technical Data Measurement Microphones

Technical Data Measurement Microphones Technical Data s Consisting of Type Classification according IEC 61672 and ANSI S1.4 Capsule / Transducer Maximum SPL @ THD 3%, 1 khz 22 Certified MA220 + MC230 or MC230A Capsule Certified -WP Outdoor

More information

Standalone High Accuracy Transformer Analysis. Basic 0.02dB with class leading high frequency performance. RS232, USB and LAN as standard

Standalone High Accuracy Transformer Analysis. Basic 0.02dB with class leading high frequency performance. RS232, USB and LAN as standard N4 Sweep Frequency Response Analyzer SFRA45 Standalone High Accuracy Transformer Analysis Leading wideband accuracy Wide frequency range Full Colour VGA Display PC software included Leading phase accuracy

More information

> Product category: > Function: > User profi le: > Frequency band: 100 KHz to 6 GHz. > Related standard: ECC/REC/(02)04, EN > Related software:

> Product category: > Function: > User profi le: > Frequency band: 100 KHz to 6 GHz. > Related standard: ECC/REC/(02)04, EN > Related software: > INSITE Free > Product category: E field narrow band measurement system with spectrum analyzer > Function: Performs in situ spot measurements, locates measurement points on a map > User profi le: Regulation

More information

NoiseMeters. The Practical & Easy To Use Solution for Industrial & Environmental Noise Measurements.

NoiseMeters. The Practical & Easy To Use Solution for Industrial & Environmental Noise Measurements. NoiseMeters The Practical & Easy To Use Solution for Industrial & Environmental Noise Measurements. Simple to use solutions for occupational, general & environmental noise measurements Meets the latest

More information

Microphones & Accessories

Microphones & Accessories Accessories of the KLIPPEL R&D and QC SYSTEMs (Document Revision1.15) FEATURES Microphones optimal for research, development and manufacturing of transducers Condenser and electret microphones High performance/cost

More information

nor140 INSTRUCTION MANUAL SOUND ANALYSER

nor140 INSTRUCTION MANUAL SOUND ANALYSER INSTRUCTION MANUAL INSTRUMENT SOFWARE 3.0 A sound level meter with built-in real time analyser capabilities complying with international instrument standards. Parallel octave fi lters are standard (optional

More information

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality

More information

Sound Meter Type

Sound Meter Type Sound Meter Type 1 840015 Sound Meter Type 1-840015 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any form

More information

Solutions ADVANCED SOLUTIONS FOR SMART COMMUNICATIONS. RADIO DISPATCHER FLEET PHONE APP BRIDGE

Solutions ADVANCED SOLUTIONS FOR SMART COMMUNICATIONS.   RADIO DISPATCHER FLEET PHONE APP BRIDGE ADVANCED SOLUTIONS FOR SMART COMMUNICATIONS IP2AIR Bridge VHF/HF IP2AIR is an advanced solution for professional two-way radios developed by ICOM FRANCE. The IP2AIR solutions enhances your experience of

More information

Testing to IEC

Testing to IEC APPENDIX B Testing to IEC61672-1 This appendix presents information for measuring the sound level meter functionality of the LxT according to IEC61672-1. Sections 5, 6, 7 and 9 (except 9.3) The following

More information

SLM-52N INSTRUCTION MANUAL

SLM-52N INSTRUCTION MANUAL ISO-TECH Sound Level Meter SLM-52N INSTRUCTION MANUAL Un Un Ov Ov CONTENTS Title Page 1. INSTRUMENT CARE... 1 2. FEATURES... 2 3. MEASUREMENT PARAMETERS... 2 4. SPECIFICATIONS... 2 5. CONTROLS AND FUNCTIONS...

More information

CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording

CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording Environmental Noise Boundary noise assessments Noise nuisance complaints Measurements

More information

Microphone Cartridge Model: MP201

Microphone Cartridge Model: MP201 BSWA MICROPHONES Established in 1998, BSWA Technology Co., Ltd is becoming a preferred microphone supplier in China and the world. With the high quality and low price strategy, many OEMs and system integrators

More information

Uses and Features. Sound Intensity emerges from the Laboratory. Sound intensity made easy

Uses and Features. Sound Intensity emerges from the Laboratory. Sound intensity made easy PRODUCT DATA Hand-held Sound Intensity System (2260 Investigator and Intensity Software BZ 7205 Type 2260E and Sound Intensity Probe Kit for 2260 Type 3595) Portable and battery-operated, the Handheld

More information

Copyright X02827C00 - Ed. 1-04/16

Copyright X02827C00 - Ed. 1-04/16 1 GHz Spectrum Analyzer Userr s manuall CHAUVIN-ARNOUX Test and Measurement Division Parc des Glaisins 6, avenue du Pré de Challes F - 74940 ANNECY-LE-VIEUX Tel. +33 (0)4.50.64.22.22 - Fax +33 (0)4.50.64.22.00

More information

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality

More information

TesT system for ConduCTed and radiated immunity

TesT system for ConduCTed and radiated immunity nsg 070 TesT system for ConduCTed and radiated immunity The, successor of the NSG 070, is a multifunctional EMC immunity test system. Its large frequency range from to G and its modular set-up using internal

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Electric and Magnetic Field Measurement For Isotropic Measurement of Magnetic and Electric Fields Evaluation of Field

More information

SW Series Impedance Tube Solutions

SW Series Impedance Tube Solutions SW Series Impedance Tube Solutions BSWA SW series Impedance Tubes can accurately measure sound absorption coefficients and impedance according to ISO or ASTM standards. They also support the sound transmission

More information

Model Microphone Preamplifier Power Supply Manual

Model Microphone Preamplifier Power Supply Manual Model 2221 Microphone Preamplifier Power Supply Manual Larson Davis Model 2221 Microphone Preamplifier Power Supply Manual I2221.01 Rev H Copyright Copyright 2009-2015 by PCB Piezotronics, Inc. This manual

More information

Exposure Level Tester ELT-400

Exposure Level Tester ELT-400 Safety Evaluation within a Magnetic Field Environment Exposure Level Tester ELT-400 Direct Evaluation of Field Exposure Compared to Major Standards (IEEE C95.6) Automatic Exposure Evaluation for Various

More information

Dante Kit MEB 114-S. Thanks to its rugged housing and its high-quality microphone capsule the MEB 114-S ensures the best speech intelligibility.

Dante Kit MEB 114-S. Thanks to its rugged housing and its high-quality microphone capsule the MEB 114-S ensures the best speech intelligibility. PRODUCT SPECIFICATION 1/6 FEATURES Great speech intelligibility Phantom power via PoE Remote controllable gain level Daisy-chaining possible DELIVERY INCLUDES 1 SL DI 4 XLR Dante interface 4 MEB 114-S

More information

Organisation Internationale de Métrologie Légale

Organisation Internationale de Métrologie Légale Organisation Internationale de Métrologie Légale INTERNATIONAL RECOMMENDATION Sound level meters Sonomètres OIML R 58 Edition 1998 (E) CONTENTS Foreword... 3 1 Scope... 4 2 Construction and maximum permissible

More information

C1.1 Specification of the SVAN 971 as SLM in the standard configuration

C1.1 Specification of the SVAN 971 as SLM in the standard configuration SVAN 971 USER MANUAL. C TECHNICAL SPECIFICATIONS C.1 Specification of SVAN 971 as sound level meter The following appendix effects for firmware version 1.11.1 or greater. C1.1 Specification of the SVAN

More information

Organisation Internationale de Métrologie Légale

Organisation Internationale de Métrologie Légale Organisation Internationale de Métrologie Légale INTERNATIONAL RECOMMENDATION Integrating-averaging sound level meters Sonomètres intégrateurs-moyenneurs OIML R 88 Edition 1998 (E) CONTENTS Foreword...

More information

Additel 875 Series Dry Well Calibrators

Additel 875 Series Dry Well Calibrators Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect

More information

System Power Amplifier (SPA)

System Power Amplifier (SPA) System Power Amplifier (SPA) Installation Guide SPA-60 Amplifi er Amplifi er EXPLANATION OF SYMBOLS The term WARNING! indicates instructions regarding personal safety. If the instructions are not followed

More information

8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE

8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE 8000 SERIES PRECISION MULTIMETER VERIFICATION AND ADJUSTMENT GUIDE TRANSMILLE LTD. Version 1.1 : Apr 2015 TABLE OF CONTENTS PREPARING FOR CALIBRATION... 4 INTRODUCTION... 4 CALIBRATION INTERVAL SELECTION...

More information

Additel 875 Series Dry Well Calibrators

Additel 875 Series Dry Well Calibrators Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect

More information

CIC ENGINEERING 345 CENTER STREET EAST PEORIA, IL PH FAX µmpis Control Software

CIC ENGINEERING 345 CENTER STREET EAST PEORIA, IL PH FAX µmpis Control Software µmpis Control Software Overview The µmpis Control software package allows for a user to control the operation of the umpis unit with a PC. The PC and the umpis unit are connected together using a RS232

More information

5790A Automated AC Measurement Standard

5790A Automated AC Measurement Standard 5790A Automated AC Measurement Standard Technical Data Accuracy that s easy to use The 5790A is a complete automated ac measurement standard designed for the most demanding calibration applications. It

More information

Dante Kit MEG FEATURES DELIVERY INCLUDES PRODUCT VARIANTS

Dante Kit MEG FEATURES DELIVERY INCLUDES PRODUCT VARIANTS PRODUCT SPECIFICATION 1/6 FEATURES Great speech intelligibility Phantom power via PoE Remote controllable gain level Daisy-chaining possible DELIVERY INCLUDES 1 SL DI 4 XLR Dante interface 4 MAT 133-S

More information

DSP40. User Manual.

DSP40. User Manual. DSP40 User Manual www.audac.eu ADDITIONAL INFORMATION This manual is put together with much care, and is as complete as could be on the publication date. However, updates on the specifications, functionality

More information

FRAX Series Sweep Frequency Response Analyzers

FRAX Series Sweep Frequency Response Analyzers FRAX Series Highest dynamic range and accuracy in the industry Fulfills international standards for SFRA measurements Advanced analysis and decision support built into the software. FRAX 150 with built

More information

Kistler LabAmp for DynoWare

Kistler LabAmp for DynoWare Electronics & Software Kistler LabAmp for DynoWare Charge Amplifier and Data Acquisition for Multicomponent Force Measurement This instrument is ideal for multicomponent force-torque measurement with piezoelectric

More information

Dante Kit MEG basic

Dante Kit MEG basic PRODUCT SPECIFICATION 1/6 FEATURES Great speech intelligibility Phantom power via PoE Remote controllable gain level Daisy-chaining possible DELIVERY INCLUDES 1 SL DI 4 XLR Dante interface 4 MAT 133 tablestands

More information

VM2000. Low-Noise Bottom Port Piezoelectric MEMS Microphone Data Sheet Vesper Technologies Inc. Differential Analog Output

VM2000. Low-Noise Bottom Port Piezoelectric MEMS Microphone Data Sheet Vesper Technologies Inc. Differential Analog Output VM2000 2017 Data Sheet Vesper Technologies Inc. Low-Noise Bottom Port Piezoelectric MEMS Microphone VM2000 Vesper offers the world s first differential analog piezoelectric MEMS microphone. VM2000 provides

More information

Application Note. Airbag Noise Measurements

Application Note. Airbag Noise Measurements Airbag Noise Measurements Headquarters Skovlytoften 33 2840 Holte Denmark Tel: +45 45 66 40 46 E-mail: gras@gras.dk Web: gras.dk Airbag Noise Measurements* Per Rasmussen When an airbag inflates rapidly

More information

Radiated immunity test system 6 GHz

Radiated immunity test system 6 GHz its 6006 The consist of an integrated RF signal generator, RF switch and interfaces. The unit is designed for various radiated EMC applications in the 80 MHz to 6 GHz frequency range. In addition to the

More information

# Digital Multimeter

# Digital Multimeter #61-797 Digital Multimeter - 1 - TABLE OF CONTENTS 1.Introduction Precautions and Safety Information Symbols Safety 2.Specifications General Specifications Electrical Specifications Required Equipment

More information

Spectrum & Power Measurements Using the E6474A Wireless Network Optimization Platform Application Note By Richard Komar

Spectrum & Power Measurements Using the E6474A Wireless Network Optimization Platform Application Note By Richard Komar Spectrum & Power Measurements Using the E6474A Wireless Network Optimization Platform Application Note By Richard Komar Contents Introduction...1 Band Clearing...2 Using the spectrum analyzer for band

More information

Precision Integrating Sound Level Meter

Precision Integrating Sound Level Meter Precision Integrating Sound Level Meter Type 2236 A 009 Type 2236 B 009 Type 2236 C 009 Type 2236 D 009 With software version 2.1 or higher Revision November 1996 Brüel & Kjær BB0909 13 Trademarks IBM

More information

5 Channel Multifunctional PWM Controller. HomLiCon LCH5T. Technical Specifications

5 Channel Multifunctional PWM Controller. HomLiCon LCH5T. Technical Specifications 5 Channel Multifunctional PWM Controller Application Control of groups LED and LED strips Control of relays, small motors, fans, etc. Control models Technical Specifications Number of Channels 5 Color

More information

PRODUCT DATA. Uses, Benefits and Features

PRODUCT DATA. Uses, Benefits and Features PRODUCT DATA Hand held Analyzer Type 2270 S for Sound Intensity Measurements with Sound Intensity Software BZ 7233 and Sound Intensity Probe Kit for 2270 Type 3654 Portable and battery operated, Hand held

More information

For Isotropic Measurement of Magnetic and Electric Fields

For Isotropic Measurement of Magnetic and Electric Fields Field Analyzers EFA-300 For Isotropic Measurement of Magnetic and Electric Fields Evaluation of Field Exposure compared to Major Standards and Guidance (selectable) Shaped Time Domain (STD) an innovative

More information

671 Series LASER WAVELENGTH METER. The Power of Precision in Wavelength Measurement. It's Our Business to be Exact! bristol-inst.

671 Series LASER WAVELENGTH METER. The Power of Precision in Wavelength Measurement. It's Our Business to be Exact! bristol-inst. 671 Series LASER WAVELENGTH METER The Power of Precision in Wavelength Measurement It's Our Business to be Exact! bristol-inst.com The 671 Series Laser Wavelength Meter is ideal for scientists and engineers

More information

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related UltraTEV Locator Portable PD (Partial Discharge) investigation system Locates, measures and records PD activity in all substation assets including cables benefits Locating and measuring PD activity to

More information

DIGITAL SOUND LEVEL DSM8930 METER USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

DIGITAL SOUND LEVEL DSM8930 METER USER S MANUAL. Please read this manual carefully and thoroughly before using this product. DIGITAL SOUND LEVEL METER USER S MANUAL DSM8930 Please read this manual carefully and thoroughly before using this product. TABLE OF CONTENTS Introduction.............................. 2 3 Key Features................................

More information

PD32-32 Channel Piezo Driver Manual and Specifications

PD32-32 Channel Piezo Driver Manual and Specifications PD32-32 Channel Piezo Driver Manual and Specifications PiezoDrive Pty. Ltd. www.piezodrive.com Contents 1 Introduction... 3 2 Warnings / Notes... 3 3 Specifications... 4 4 Output Voltage Range... 5 4.1

More information

2260 INVESTIGATOR MODULAR PRECISION SOUND ANALYZER WITH APPLICATION SOFTWARE BZ 7210, BZ 7203, BZ 7204, BZ 7205, BZ 7206, BZ 7207, BZ 7208

2260 INVESTIGATOR MODULAR PRECISION SOUND ANALYZER WITH APPLICATION SOFTWARE BZ 7210, BZ 7203, BZ 7204, BZ 7205, BZ 7206, BZ 7207, BZ 7208 BF0213-11_Original_26-35.qxd 16-12-2003 08:52 Page 30 2260 INVESTIGATOR MODULAR PRECISION SOUND ANALYZER WITH APPLICATION SOFTWARE BZ 7210, BZ 7203, BZ 7204, BZ 7205, BZ 7206, BZ 7207, BZ 7208 Where Do

More information

The Nor121 Analyser. - for any Environmental or Building Acoustic measurement

The Nor121 Analyser. - for any Environmental or Building Acoustic measurement Product Data The Nor121 Analyser - for any Environmental or Building Acoustic measurement Alightweight, rugged and hand-held analyser with 80 or 120dB dynamic range, single or dual channel capability,

More information

MODEL INFORMATION. Model AWRMS TM 200. Automated Winding Resistance Measurement System

MODEL INFORMATION. Model AWRMS TM 200. Automated Winding Resistance Measurement System Model AWRMS TM 200 Automated Winding Resistance Measurement System Currents up to 200A for performing Winding Resistance and Heat Run Tests. Heavy Duty Protection Circuit. Accuracy with Four Wire Measurements

More information

Agilent EPM Series Power Meters

Agilent EPM Series Power Meters Agilent EPM Series Power Meters The standard just got better! What s new? Fast measurement speeds (up to 200 readings per second) Wide dynamic range sensors (-70 dbm to +44 dbm), sensor dependent Calibration

More information

Progress driven by research

Progress driven by research 2 CESVA Serving acoustics for over 40 years The company was founded in 1969 in Barcelona. It specialises in the research, development, manufacture and sale of instruments for the measurement and control

More information

An automatic method to detect defaults in the measurement chain of a sound level meter, used for unattended noise measurements

An automatic method to detect defaults in the measurement chain of a sound level meter, used for unattended noise measurements An automatic method to detect defaults in the measurement chain of a sound level meter, used for unattended noise measurements E. Aflalo a, F. Dupont a, P. Cellard b and J.-N. Durocher b a 01dB-Metravib,

More information

MC108A-2 RF MULTI-COUPLER USER S GUIDE

MC108A-2 RF MULTI-COUPLER USER S GUIDE MC108A-2 RF MULTI-COUPLER USER S GUIDE Systems Engineering & Management Company 1430 Vantage Court Vista, California 92081 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS DOCUMENT CONSTITUTES

More information

Programmable AC Power Source Model 9801

Programmable AC Power Source Model 9801 Data Sheet Programmable AC Power Source The 9801 is both a programmable AC power source and measurement tool in a compact benchtop package. This fully programmable linear AC source delivers up to 300 VA

More information

VX-3000 Series Voice Alarm and Public Address System

VX-3000 Series Voice Alarm and Public Address System VX-3000 Series Voice Alarm and Public Address System VX-3000 SERIES Combined highly integrated voice alarm and public address system. The issue of security is more than ever important. Our VX-3000 is a

More information

DPA74/154 AUDAC PROFESSIONAL AUDIO EQUIPMENT. DPA74/154 Quad Channel Class-D Amplifier. User Manual & Installation Guide

DPA74/154 AUDAC PROFESSIONAL AUDIO EQUIPMENT. DPA74/154 Quad Channel Class-D Amplifier. User Manual & Installation Guide DPA74/154 PROFESSIONAL AUDIO EQUIPMENT DPA74/154 Quad Channel Class-D Amplifier AUDAC User Manual & Installation Guide AUDAC PROFESSIONAL AUDIO EQUIPMENT User Manual & Installation Guide AUDAC http://www.audac.eu

More information

PRODUCT DATA. Hand-held Sound Intensity System Type 2270-G Sound Intensity Software BZ-7233 Sound Intensity Probe Kit for 2270 Type 3654

PRODUCT DATA. Hand-held Sound Intensity System Type 2270-G Sound Intensity Software BZ-7233 Sound Intensity Probe Kit for 2270 Type 3654 PRODUCT DATA Hand-held Sound Intensity System Type 2270-G Sound Intensity Software BZ-7233 Sound Intensity Probe Kit for 2270 Type 3654 Portable and battery operated, Hand-held Sound Intensity System Type

More information

USER MANUAL SVAN 971 POCKET-SIZE SOUND LEVEL METER & ANALYSER. Copyright 2018 SVANTEK. All rights reserved.

USER MANUAL SVAN 971 POCKET-SIZE SOUND LEVEL METER & ANALYSER. Copyright 2018 SVANTEK. All rights reserved. USER MANUAL SVAN 971 POCKET-SIZE SOUND LEVEL METER & ANALYSER Warsaw, 28-03-2018 Copyright 2018 SVANTEK. All rights reserved. SVAN 971 User 2 Note: On account of continuous product improvement SVANTEK

More information

Operators Manual For Spectrum Analyser SA97

Operators Manual For Spectrum Analyser SA97 Included with: Padded nylon carrying case. Mains battery charger. Car cigarette lighter charger lead. Quick reference card. RS232 interface socket. Operators Manual For Spectrum Analyser SA97 Features

More information

DM 800H Twin Handheld UHF System (863.0Mhz-865.0Mhz)

DM 800H Twin Handheld UHF System (863.0Mhz-865.0Mhz) DM 800H Twin Handheld UHF System (863.0Mhz-865.0Mhz) User Manual Order code: MIC78 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before

More information

FTB-3930 MULTITEST MODULE. Platform Compatibility

FTB-3930 MULTITEST MODULE. Platform Compatibility MULTITEST MODULE FTB-3930 NETWORK TESTING OPTICAL FasTesT TM : three-wavelength measurement of optical loss, ORL and fi ber length in 10 seconds All-in-one portable test solution: up to eight instruments

More information

Smart Measurement Solutions. Bode 100. User Manual

Smart Measurement Solutions. Bode 100. User Manual Smart Measurement Solutions Bode 100 User Manual Bode 100 User Manual Bode 100 User Manual Article Number VESD0661 - Manual Version: Bode100.AE.4 OMICRON Lab 2010. All rights reserved. This User Manual

More information

UltraTEV Locator Portable Partial Discharge (PD) investigation system.

UltraTEV Locator Portable Partial Discharge (PD) investigation system. UltraTEV Locator Portable Partial Discharge (PD) investigation system Locates, measures and records PD activity in all substation assets including cables www.eatechnologyusa.com Benefits Locating and measuring

More information

Selective and broadband low frequency field analysis

Selective and broadband low frequency field analysis ELECTRIC AND MAGNETIC FIELD ANALYZER EHP-50C Selective and broadband low frequency field analysis Electric and magnetic low frequency field analysis up to 100 khz Isotropic measurement with a dynamic range

More information

FRAX Series Sweep Frequency Response Analyzers

FRAX Series Sweep Frequency Response Analyzers FRAX Series Highest dynamic range and accuracy in the industry Fulfills international standards for SFRA measurements Advanced analysis and decision support built into the software Imports data from other

More information

SC420. Sound Level Meter Spectrum Analyser USER MANUAL. M_SC420_v0014_ _ENG

SC420. Sound Level Meter Spectrum Analyser USER MANUAL. M_SC420_v0014_ _ENG SC420 Sound Level Meter Spectrum Analyser USER MANUAL M_SC420_v0014_20150522_ENG Since its beginnings in Barcelona in 1969, has been devoted to manufacturing sound equipment and instrumentation through

More information

Hydrophone TC4032 Low Noise Sea-State Zero Hydrophone

Hydrophone TC4032 Low Noise Sea-State Zero Hydrophone TC4032 Low noise performance High sensitivity Wide frequency range Flat frequency response Long term stability Individually calibrated The TC4032 general purpose hydrophone offers a high sensitivity, low

More information

Installation guide M B. RSU10 USB interface

Installation guide M B. RSU10 USB interface Installation guide M-9904-8092-03-B RSU10 USB interface 2008-2011 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any other media

More information

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc HSI Series Modules Selection Guide HSI Series Modules Single channel High bandwidth - for dynamic signals Isolation (all models Analog signal output (±5 V Single channel modularity For DEWETRON systems

More information

Supplementary User Manual for BSWA Impedance Tube Measurement Systems

Supplementary User Manual for BSWA Impedance Tube Measurement Systems Supplementary User Manual for BSWA Impedance Tube Measurement Systems 1 P age Contents Software Installation... 3 Absorption Measurements -- ASTM Method... 4 Hardware Set-Up... 4 Sound card Settings...

More information

ODEON APPLICATION NOTE ISO Open plan offices Part 2 Measurements

ODEON APPLICATION NOTE ISO Open plan offices Part 2 Measurements ODEON APPLICATION NOTE ISO 3382-3 Open plan offices Part 2 Measurements JHR, May 2014 Scope This is a guide how to measure the room acoustical parameters specially developed for open plan offices according

More information

SC160. Integrating Sound Level Meter Real time frequency Analyser* in Octave Band

SC160. Integrating Sound Level Meter Real time frequency Analyser* in Octave Band D_SC160_v0041_20111212_ENG Applications Evaluation of the noise exposure of workers at workplace simultaneously to the verification of PPE (Personal Protective Equipment) Room acoustics: NC and NR evaluation,

More information

Digital Function Generator

Digital Function Generator Digital Function Generator 13654-99 PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 37079 Göttingen Germany Tel. +49 (0) 551 604-0 Fax +49 (0) 551 604-107 E-mail info@phywe.de Operating Instructions

More information

LDC Channels of Laser Diode Control. 16-Channel Laser Diode Controller. Product Features

LDC Channels of Laser Diode Control. 16-Channel Laser Diode Controller. Product Features Product Features 16 independent, isolated channels for laser and TEC control Wide variety of laser controller modules (current and temperature) with up to 3A available per channel Dual channel laser current

More information

PRODUCT DATA. Applications. Uses

PRODUCT DATA. Applications. Uses PRODUCT DATA Impedance Tube Kit (50 Hz 6.4 khz) Type 4206 Impedance Tube Kit (100 Hz 3.2 khz) Type 4206-A Transmission Loss Tube Kit (50 Hz 6.4 khz) Type 4206-T Brüel & Kjær offers a complete range of

More information

TBM - Tone Burst Measurement (CEA 2010)

TBM - Tone Burst Measurement (CEA 2010) TBM - Tone Burst Measurement (CEA 21) Software of the R&D and QC SYSTEM ( Document Revision 1.7) FEATURES CEA21 compliant measurement Variable burst cycles Flexible filtering for peak measurement Monitor

More information

CL55C CLICK ANALYSER The cost competitive, PC-driven, automatic, multi-channel discontinuous interference analyser

CL55C CLICK ANALYSER The cost competitive, PC-driven, automatic, multi-channel discontinuous interference analyser CL55C CLICK ANALYSER The cost competitive, PC-driven, automatic, multi-channel discontinuous interference analyser According to CISPR 14-1, Designed in compliance with CISPR 16-1, Advanced software for

More information

Bode 100. User Manual

Bode 100. User Manual Bode 100 User Manual Bode 100 User Manual Article Number VESD0661 - Manual Version: Bode100.AE.3 OMICRON Lab 2008. All rights reserved. This User Manual is a publication of OMICRON electronics GmbH. This

More information

10.00 (1/2) PAC series

10.00 (1/2) PAC series Clamp-on AC/DC current probes PAC Series The is a range of professional AC/DC clamp-on current probes designed to meet the very latest in safety and performance standards. There are two different jaw designs

More information

English. Operating manual. Integrating Sound Level Meter Spectrum Analyzer HD2010UC/A. Keep for future reference.

English. Operating manual. Integrating Sound Level Meter Spectrum Analyzer HD2010UC/A.  Keep for future reference. English Operating manual Integrating Sound Level Meter Spectrum Analyzer HD2010UC/A Companies / Brands of GHM www.deltaohm.com Keep for future reference. 1 2 3 27 4 26 5 6 7 25 24 23 8 9 10 11 12 13 22

More information

OPERATING MANUAL. Measurement Microphones

OPERATING MANUAL. Measurement Microphones OPERATING MANUAL Measurement Microphones Contact NTi Audio at Headquarters +423 239 6060 info@nti-audio.com Americas +1 503 684 7050 americas@nti-audio.com China +86 512 6802 0075 china@nti-audio.com Czech

More information