1 Radiation Hardness Evaluation of the Analog Devices AD9042 ADC for use in the CMS Electromagnetic Calorimeter P. Denes, B. Lev, R. Wixted Physics Department, Princeton University, Princeton NJ 08544, USA 1 We report on the results of an irradiation study carried out on devices from all wafers in a lot of AD MHz 12-bitADCs. These devices were irradiated in a 72 MeV proton beam in order to simulate the eects in CMS at the LHC. No change in dynamic performance was observed for doses up to Gy along with n=cm 2. The uniform behavior of all devices in the lot also indicates that radiation hardness can be assured by sampling tests on devices from one wafer in the lot. 1 Introduction The CMS Electromagnetic Calorimeter[1] will consist of lead tungstate (PbWO 4 ) crystals arranged in a barrel and two endcaps. The scintillation light from the crystals is captured by a photodetector, amplied, digitized and transported by high-speed ber-optic links o the detector. The digitizing electronics on the detector must survive a total absorbed dose of 10 3 (10 4 ) Gy in the barrel (endcaps) along with a uence of n=cm 2 in the barrel over the lifetime of the detector, which is dened to be the amount of time required to obtain an integrated luminosityof510 5 pb,1. The endcap photodetectors must operate up to n=cm 2, however the digitizing electronics will be placed in such a way as to limit the total uence to n=cm 2. The signal capture electronics consists of a custom monolithic wide dynamic range preamplier[2] and gain-multiplexing circuit[3] followed by the Analog Devices AD MHz 12-bit ADC. The preamplier converts the photocurrent intoavoltage with a dynamic range of 16 bits. This voltage is then ampli- 1 This work supported in part by the U.S. Department of Energy under Grant DE-FG02-91ER40671 Preprint submitted to Elsevier Preprint 10 May 1998

2 ed by four clamping ampliers with gains of 1; 4; 8; 32. The gain-multiplexing circuit simultaneously samples each of these four voltages at the LHC bunch crossing frequency of 40 MHz. Voltage comparators and digital logic in the circuit then determine which of the four voltage samples is the largest (corresponding to the highest gain) below a certain saturation threshold. This (quasi-static) voltage is multiplexed and digitized by the AD9042. The output data consist of a oating-point representation of the data in the form G 2 G 1 D 12 D 11 D 10 D 9 D 8 D 7 D 6 D 5 D 4 D 3 D 2 D 1 where G i is a 2-bit code representing the gain range used (1; 4; 8; 32) and D i is the 12-bit ADC mantissa. In this way, the 12-bit ADC converts the full 16-bit dynamic range. Radiation hardness is a key concern for electronics at the LHC. The custom circuits being developed for the CMS Electromagnetic Calorimeter are fabricated in radiation-hard processes. The (commercial) AD9042 is fabricated in Analog Devices' proprietary XFCB 1.0 (extra Fast Complementary Bipolar) process. Although the intrinsic properties of the process and the design techniques used in the ADC result in a radiation-hard part, the part is not formally guaranteed to be radiation hard. In order to ensure that the ADCs for CMS meet the radiation hardness requirements listed above, CMS and Analog Devices (ADI) have dened the process ow shown in Figure 1. In this ow, lots of 18 wafers are fabricated and probed to determine functional die. The rst wafer is diced, and roughly 20 parts are packaged and tested under irradiation. If these parts perform as required after irradiation, the entire lot is accepted, otherwise the entire lot is rejected. The cycle time for the complete process is about 21 weeks, and about 20 cycles would be needed to provide ADCs for CMS. The process ow ensures radiation hard parts provided that the radiation hardness of all wafers in a lot is uniform. In order to prove this, we have performed tests on ADCs from one wafer lot, in a way which simulates the nal ow. A lot of 17 wafers of AD9042 was fabricated in April Twenty ADCs from the rst wafer were isolated and packaged. These ADCs were then tested under irradiation. After packaging of the remaining 16 wafers, ADCs were selected at random from each wafer such that sets of 32 ADCs per wafer were obtained. Of the 512 ADCs delivered, 4 from each wafer were reserved for future tests, and the remaining 28 ADCs per wafer were then tested under irradiation as described below. 2

3 ADI Fab Lot 18 wafers Probe entire Lot Dice 1 Wafer Pkg ~ 20 die Dice entire Lot CMS Test (Irradiate) Accept? Week Delivered Parts 21 2 Test Description Fig. 1. ADC Process ow for CMS Calorimeter electronics in the LHC radiation environment will be subjected primarily to ionizing radiation and neutron uence. In order to simulate these eects simultaneously, we have performed irradiation measurements using the OPTIS proton beam at PSI[5]. The beam consists of 72 MeV protons, emitted over 10 cm 2. The nominal operating ux was 1: p=cm 2 =s. At these energies, the proton energy deposition is ve times greater than for minimum ionizing particles. Similarly, the damage induced by one 72 MeV proton is equivalent to that of two 1 MeV neutrons. A two hour exposure at the nominal ux thus simulates the eects of a total dose of 10 4 Gy along with n=cm 2, corresponding to the full lifetime of almost all of the CMS Electromagnetic Calorimeter. In CMS, the ADCs will sample the voltage waveform output of the oating point preamplier. The most natural way to test for eects due to irradiation would thus be to use simulated waveforms and try to quantify changes arising after irradiation. Although this approach would best illustrate the eects in CMS, it makes it more dicult to isolate and quantify the eects. For this reason, the sine waves of various frequencies and amplitudes were measured rather than preamplied pulses. The reference signal frequency for our measurements is 5 MHz, as this represents the bandwidth of the preamplier. 3

4 ADCs were irradiated either under full operating conditions or unbiased. Radiation induced eects appear to be slightly enhanced for unbiased devices. Unbiased devices were measured before and after irradiation, and operating devices were measured continuously during irradiation. (An advantage of proton beam irradiation is that the beam spot is well dened, so that additional electronics around the device under test need not be radiation hard.) The test arrangementisshown schematically in Figure 2. Sine waves were generated with an HP3335A synthesizer. The ADC was clocked with a dierential AC-coupled PECL clock running at a constant 40 MHz, and the resulting ADC data were stored in a 4 kilo-sample FIFO memory. As the CMS application is unipolar, DC coupling was simulated with the buer amplier shown in Figure 2. This arrangement also allowed dierent osets to be used for comparison.,q 5HI 0+] &ORFNV $'& Fig. 2. ADC measurement setup. A sine wave is DC-coupled to the ADC, which hsa AC-coupled dierential PECL clocks. The ADCs were characterized with 1.2, 2.5, 5.0 and 9.6 MHz sine waves, with full-scale amplitudes ranging from about 40 mv to 900 mv (the full-scale range of the ADC is 1 V). These sine waves were digitized at 40 MHz, and the results stored in the 4 kilo-sample buer. Normally, the ADC performance would be obtained by a fast Fourier transform (FFT) of the stored data. However, as the 40 MHz clock (from a quartz crystal) was not a precise multiple of the sine wave frequency, spectral leakage can obscure certain eects. In analyzing the data, therefore, a pure sine wave was rst t to the data, and an FFT was performed on the data with the t subtracted. The t thus determines the amplitude and oset of the sine wave, and the FFT was used to calculate the Signal-to-Noise Ratio (SNR) and other measures of dynamic performance. The uniformity of the conversion gains, derived before irradiation, is illustrated in Figures 3 and 4. Here, the gain of the ADC was obtained by using the t results for the dierent amplitudes of 5 MHz sine waves. The gain is shown in Figure 3 for the dierent wafers. The plotted value for each point represents the average of the 28 ADCs/wafer prior to irradiation, and the error bar represents the RMS of the distribution of amplitudes for the 28 ADCs. The 4

5 distribution when all ADCs are taken together is shown in Figure 4, with an RMS dispersion of 0.7% of the mean value. *DLQ :DIHU Fig. 3. Conversion gain at 5 MHz as a function of wafer number. The open squares represent the average of the ADCs prior to irradiation, and the error bars the RMS Gain Fig. 4. Conversion gain at 5 MHz for all ADCs, i.e. a histogram of the data in Figure 3. The RMS is 0.7% of the mean. 3 Results Of the 512 ADCs (32 ADCs per wafer 16 wafers) 416 were irradiated up to a total dose of p=cm 2 (which simulates the full life of the barrel CMS Electromagnetic Calorimeter), 32 up to a total dose of p=cm 2, and 32 up to a total dose of p=cm 2. The SNR before and after irradiation is summarized in Table 1. The use of sockets, and the somewhat noisy accelerator environment, resulted in a typical SNR of about -63 db rather than the -67 db specied for the device[4]. As seen from Table 1, the average change in SNR for ADCs irradiated at p=cm 2 was 0:0 1:2 db, for ADCs irradiated at p=cm 2 was 0:1 1:0 5

6 Dose f SNR [db] p=cm 2 MHz Before After ,63:1 0:8,63:2 0: ,63:1 0:8,63:2 0: ,63:0 0:8,61:6 1: ,63:3 0:9,63:4 1: ,63:5 0:8,63:7 0: ,63:5 0:6,62:1 1: ,63:5 1:1,63:7 1: ,63:6 0:6,63:7 0: ,63:7 0:7,62:2 1: ,63:4 0:6,63:3 0: ,63:3 0:7,63:4 0: ,63:3 0:6,62:0 1:1 Table 1 SNR for the ADCs before and after irradiation. For ADCs irradiated at db, and for ADCs irradiated at p=cm 2 was 1:4 1:6 db. Thus no degradation in SNR was observed at doses up to p=cm 2. At double that dose, a decrease in performance was apparent with a loss of 1:4 db in SNR. Similar eects were observed for the spurious free dynamic range, which is given by the worst harmonic (as a fraction of full-scale) in Table 2. As before, the behavior is similar at doses of p=cm 2 and p=cm 2. Also, a decrease in performance is observed at doses of p=cm 2. In addition, a decrease in post-irradiation performance is observed for input frequencies above 5 MHz. These results are displayed graphically in Figures 5 and 6 which show the change in 5 MHz SNR for all devices irradiated up to doses of p=cm 2.In Figure 5, the change after irradiation is plotted as a function of wafer, and shows the very similar behavior from wafer to wafer. The change for all wafers is shown in Figure 6, and displays a Gaussian shape. 6

7 Dose f Worst Spur [db FS ] p/cm 2 MHz Before After ,78:8 2:6,79:0 2: ,79:6 1:7,79:2 2: ,80:1 2:6,75:2 3: ,77:8 2:6,78:1 2: ,78:9 1:7,78:1 3: ,78:2 2:7,75:4 3: ,77:8 2:8,76:1 2: ,77:7 2:6,75:9 2: ,78:4 3:1,74:9 3: ,79:1 2:9,76:7 1: ,79:7 2:8,76:6 1: ,78:9 2:4,75:7 3:8 Table 2 Worst spur (largest harmonic) for the ADCs before and after irradiation. Change in 5 MHz SNR [db] Wafer Fig. 5. Change in 5 MHz SNR for ADCs exposed to p=cm 2 as a function of wafer number. The open squares represent the average of the ADCs irradiated, and the error bars the RMS. 4 Discussion and Conclusions For doses of p=cm 2, which correspond to 10 4 Gy along with n=cm 2 there was no statistically signicant change in dynamic performance for the 416 ADCs evaluated at this dose. Similarly, the 32 ADCs irradiated to p=cm 2 did not appear to degrade after irradiation. For the 32 ADCs irradiated to p=cm, however, a small decrease in dynamic performance was observed. For static performance, all ADCs showed a change in conversion 7

8 Change in 5 MHz SNR [db] Fig. 6. Change in 5 MHz SNR for all ADCs exposed to p=cm 2, i.e. a histogram of the data in 5 gain with irradiation. In order to elucidate this eect, ADCs were studied in detail during irradiation. Figure 7 shows an example of the change in amplitude with irradiation. A 5 MHz sine wave, near full scale, was measured during irradiation. The (normalized) amplitude shown in Figure 7 is the ratio of the ADC reading at the indicated dose, divided by the initial reading. As can be seen, the full scale of the ADC increased about 1% during the irradiation, so that the measured amplitude decreased by about 1%. Simultaneously, the value of the ADC internal voltage reference (that is used in setting the gain) was measured, and was found to increase about 20 mv after irradiation. 9 5HI >9@ ( ( ( ( ( 1RUPDOL]HG$PSOLWXGH Fig. 7. Amplitude and voltage reference change during irradiation. The crosses indicate the measured value of the ADC voltage reference on the left-hand scale, and the triangles indicate the normalized change in amplitude for a 5 MHz full scale sine wave on the right-hand scal. The change in reference voltage and measured amplitude are completely correlated. If one "corrects" the data by adjusting the ADC scale by the measured reference voltage, one recovers a straight line for the amplitude, with no measurable slope. It is felt that the change in reference voltage, and thus the ADC gain, arises for the following reason: The voltage reference circuit makes use of 8

9 a temperature-compensated current that is created by a bipolar current mirror whose transistors have dierent emitter areas. With irradiation, the DC current gain of the bipolar transistors diminishes, and the resulting increase in base current causes an error in the reference current. While this eect is dicult to correct in the ADC, it is relatively easy to correct in CMS by including a special radiation-hard reference in the front-end gain-multiplexing circuit. The value of this reference would be periodically measured as an oline correction to the amplitude. This reference must also be temperature compensated, but the precise voltage value of the reference is not important, only that it is stable. We have measured roughly 500 AD9042 ADCs from all wafers in a lot and nd the pre- and post-irradiation properties of all ADCs to be essentially identical. At doses of p=cm 2, which correspond to Gy along with n=cm 2, no signicant change in dynamic performance was observed. A small decrease in conversion gain was observed, which is completely correctable with the addition of some extra circuitry. The pre- and post-irradiation behavior of the AD9042 thus meet the electrical requirements for the CMS Electromagnetic Calorimeter. Finally, the very uniform characteristics of the ADCs from dierent wafers serve to validate the production process ow envisaged, thus ensuring that all ADCs maintain their performance throughout the life of the experiment. 5 Acknowledgments The authors wish to express their gratitude to Tom Gratzek and Frank Murden of Analog Devices for their help in the rapid implementation of these tests, and their continued technical assistance. In addition, the authors would like to acknowledge the support from their PSI colleagues and the accelerator operators at OPTIS throughout these tests. References [1] CMS Collaboration, The Electromagnetic Calorimeter Project Technical Design Report (CERN/LHCC 97-33, 1997). [2] J.-P. Walder, High Dynamic Range and Low Power Very-Front end Preamplier for CMS Calorimetry, in: Second Workshop on Electronics for LHC Experiments (Balatonfured, 1996) 61. 9

10 [3] P. Denes, CMS Electromagnetic Calorimeter Readout, in: Second Workshop on Electronics for LHC Experiments (Balatonfured, 1996) 48. [4] Analog Devices, Inc., AD Bit, 41 MSPS Monolithic A/D Converter (1996). [5] PSI User's Guide (Paul Scherrer Institut, Villigen, Switzerland, 1994). 10

A Low-Power, Radiation-Hard Gigabit Serializer for use in the CMS Electromagnetic Calorimeter

A Low-Power, Radiation-Hard Gigabit Serializer for use in the CMS Electromagnetic Calorimeter IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 47, NO. 1, FEBRUARY 2000 13 A Low-Power, Radiation-Hard Gigabit Serializer for use in the CMS Electromagnetic Calorimeter P. Denes, S. Baier, Member, IEEE, J.-M.

More information

K. Desch, P. Fischer, N. Wermes. Physikalisches Institut, Universitat Bonn, Germany. Abstract

K. Desch, P. Fischer, N. Wermes. Physikalisches Institut, Universitat Bonn, Germany. Abstract ATLAS Internal Note INDET-NO-xxx 28.02.1996 A Proposal to Overcome Time Walk Limitations in Pixel Electronics by Reference Pulse Injection K. Desch, P. Fischer, N. Wermes Physikalisches Institut, Universitat

More information

CMS Conference Report

CMS Conference Report Available on CMS information server CMS CR 2004/067 CMS Conference Report 20 Sptember 2004 The CMS electromagnetic calorimeter M. Paganoni University of Milano Bicocca and INFN, Milan, Italy Abstract The

More information

PERFORMANCE OF THE CMS ECAL LASER MONITORING SOURCE IN THE TEST BEAM

PERFORMANCE OF THE CMS ECAL LASER MONITORING SOURCE IN THE TEST BEAM PERFORMANCE OF THE CMS ECAL LASER MONITORING SOURCE IN THE TEST BEAM A. BORNHEIM CALTECH 2 E. California Blvd., Pasadena, CA 925, USA E-mail: bornheim@hep.caltech.edu On behalf of the CMS ECAL Collaboration.

More information

Design of the Front-End Readout Electronics for ATLAS Tile Calorimeter at the slhc

Design of the Front-End Readout Electronics for ATLAS Tile Calorimeter at the slhc IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 60, NO. 2, APRIL 2013 1255 Design of the Front-End Readout Electronics for ATLAS Tile Calorimeter at the slhc F. Tang, Member, IEEE, K. Anderson, G. Drake, J.-F.

More information

Forward Endcap Analog Electronics

Forward Endcap Analog Electronics Forward Endcap Analog Electronics Thomas Held Ruhr-Universität Bochum Institut für Experimentalphysik I PANDA DAQ FEE Workshop, KVI Groningen March 31st, 2016 Outline 1 Forward Endcap Calorimeter Overview

More information

The CMS Silicon Strip Tracker and its Electronic Readout

The CMS Silicon Strip Tracker and its Electronic Readout The CMS Silicon Strip Tracker and its Electronic Readout Markus Friedl Dissertation May 2001 M. Friedl The CMS Silicon Strip Tracker and its Electronic Readout 2 Introduction LHC Large Hadron Collider:

More information

AN INITIAL investigation into the effects of proton irradiation

AN INITIAL investigation into the effects of proton irradiation IEEE TRANSACTIONS ON ELECTRON DEVICES, VOL. 53, NO. 2, FEBRUARY 2006 205 Proton Irradiation of EMCCDs David R. Smith, Richard Ingley, and Andrew D. Holland Abstract This paper describes the irradiation

More information

Towards an ADC for the Liquid Argon Electronics Upgrade

Towards an ADC for the Liquid Argon Electronics Upgrade 1 Towards an ADC for the Liquid Argon Electronics Upgrade Gustaaf Brooijmans Upgrade Workshop, November 10, 2009 2 Current LAr FEB Existing FEB (radiation tolerant for LHC, but slhc?) Limits L1 latency

More information

Radiation Test Report Paul Scherer Institute Proton Irradiation Facility

Radiation Test Report Paul Scherer Institute Proton Irradiation Facility the Large Hadron Collider project CERN CH-2 Geneva 23 Switzerland CERN Div./Group RadWG EDMS Document No. xxxxx Radiation Test Report Paul Scherer Institute Proton Irradiation Facility Responsibility Tested

More information

The CMS ECAL Laser Monitoring System

The CMS ECAL Laser Monitoring System The CMS ECAL Laser Monitoring System IPRD 2008 11th Topical Seminar On Innovative Particle and Radiation Detectors Adi Bornheim California Institute of Technology On behalf of the CMS ECAL Collaboration

More information

The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC

The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC Journal of Physics: Conference Series OPEN ACCESS The CMS electromagnetic calorimeter barrel upgrade for High-Luminosity LHC To cite this article: Philippe Gras and the CMS collaboration 2015 J. Phys.:

More information

OPTICAL LINK OF THE ATLAS PIXEL DETECTOR

OPTICAL LINK OF THE ATLAS PIXEL DETECTOR OPTICAL LINK OF THE ATLAS PIXEL DETECTOR K.K. Gan, W. Fernando, P.D. Jackson, M. Johnson, H. Kagan, A. Rahimi, R. Kass, S. Smith Department of Physics, The Ohio State University, Columbus, OH 43210, USA

More information

Evaluation of the Radiation Tolerance of Several Generations of SiGe Heterojunction Bipolar Transistors Under Radiation Exposure

Evaluation of the Radiation Tolerance of Several Generations of SiGe Heterojunction Bipolar Transistors Under Radiation Exposure 1 Evaluation of the Radiation Tolerance of Several Generations of SiGe Heterojunction Bipolar Transistors Under Radiation Exposure J. Metcalfe, D. E. Dorfan, A. A. Grillo, A. Jones, F. Martinez-McKinney,

More information

Final Results from the APV25 Production Wafer Testing

Final Results from the APV25 Production Wafer Testing Final Results from the APV Production Wafer Testing M.Raymond a, R.Bainbridge a, M.French b, G.Hall a, P. Barrillon a a Blackett Laboratory, Imperial College, London, UK b Rutherford Appleton Laboratory,

More information

Monolithic Pixel Sensors in SOI technology R&D activities at LBNL

Monolithic Pixel Sensors in SOI technology R&D activities at LBNL Monolithic Pixel Sensors in SOI technology R&D activities at LBNL Lawrence Berkeley National Laboratory M. Battaglia, L. Glesener (UC Berkeley & LBNL), D. Bisello, P. Giubilato (LBNL & INFN Padova), P.

More information

Noise Measurements Using a Teledyne LeCroy Oscilloscope

Noise Measurements Using a Teledyne LeCroy Oscilloscope Noise Measurements Using a Teledyne LeCroy Oscilloscope TECHNICAL BRIEF January 9, 2013 Summary Random noise arises from every electronic component comprising your circuits. The analysis of random electrical

More information

Military Performance Specifications

Military Performance Specifications RADIATION OWNER S MANUAL RHA-Related Documents Military Performance Specifications 19500 General Specification for Semiconductor Devices 38534 Performance Specifications for Hybrid Microcircuits 38535

More information

Four-Channel Sample-and-Hold Amplifier AD684

Four-Channel Sample-and-Hold Amplifier AD684 a FEATURES Four Matched Sample-and-Hold Amplifiers Independent Inputs, Outputs and Control Pins 500 ns Hold Mode Settling 1 s Maximum Acquisition Time to 0.01% Low Droop Rate: 0.01 V/ s Internal Hold Capacitors

More information

Study of the radiation-hardness of VCSEL and PIN

Study of the radiation-hardness of VCSEL and PIN Study of the radiation-hardness of VCSEL and PIN 1, W. Fernando, H.P. Kagan, R.D. Kass, H. Merritt, J.R. Moore, A. Nagarkara, D.S. Smith, M. Strang Department of Physics, The Ohio State University 191

More information

Results of FE65-P2 Pixel Readout Test Chip for High Luminosity LHC Upgrades

Results of FE65-P2 Pixel Readout Test Chip for High Luminosity LHC Upgrades for High Luminosity LHC Upgrades R. Carney, K. Dunne, *, D. Gnani, T. Heim, V. Wallangen Lawrence Berkeley National Lab., Berkeley, USA e-mail: mgarcia-sciveres@lbl.gov A. Mekkaoui Fermilab, Batavia, USA

More information

Design and Test of a 65nm CMOS Front-End with Zero Dead Time for Next Generation Pixel Detectors

Design and Test of a 65nm CMOS Front-End with Zero Dead Time for Next Generation Pixel Detectors Design and Test of a 65nm CMOS Front-End with Zero Dead Time for Next Generation Pixel Detectors L. Gaioni a,c, D. Braga d, D. Christian d, G. Deptuch d, F. Fahim d,b. Nodari e, L. Ratti b,c, V. Re a,c,

More information

The CMS ECAL Laser Monitoring System

The CMS ECAL Laser Monitoring System The CMS ECAL Laser Monitoring System CALOR 2006 XII INTERNATIONAL CONFERENCE on CALORIMETRY in HIGH ENERGY PHYSICS Adi Bornheim California Institute of Technology Chicago, June 8, 2006 Introduction CMS

More information

Total Absorption Dual Readout Calorimetry R&D

Total Absorption Dual Readout Calorimetry R&D Available online at www.sciencedirect.com Physics Procedia 37 (2012 ) 309 316 TIPP 2011 - Technology and Instrumentation for Particle Physics 2011 Total Absorption Dual Readout Calorimetry R&D B. Bilki

More information

AVALANCHE PHOTODIODES FOR THE CMS ELECTROMAGNETIC CALORIMETER

AVALANCHE PHOTODIODES FOR THE CMS ELECTROMAGNETIC CALORIMETER AVALANCHE PHOTODIODES FOR THE CMS ELECTROMAGNETIC CALORIMETER B. Patel, R. Rusack, P. Vikas(email:Pratibha.Vikas@cern.ch) University of Minnesota, Minneapolis, U.S.A. Y. Musienko, S. Nicol, S.Reucroft,

More information

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes Application Note 1493 Table of Contents Introduction........................

More information

National Accelerator Laboratory

National Accelerator Laboratory Fermi National Accelerator Laboratory FERMILAB-Conf-97/343-E D0 Preliminary Results from the D-Zero Silicon Vertex Beam Tests Maria Teresa P. Roco For the D0 Collaboration Fermi National Accelerator Laboratory

More information

AN increasing number of video and communication applications

AN increasing number of video and communication applications 1470 IEEE JOURNAL OF SOLID-STATE CIRCUITS, VOL. 32, NO. 9, SEPTEMBER 1997 A Low-Power, High-Speed, Current-Feedback Op-Amp with a Novel Class AB High Current Output Stage Jim Bales Abstract A complementary

More information

New Features of IEEE Std Digitizing Waveform Recorders

New Features of IEEE Std Digitizing Waveform Recorders New Features of IEEE Std 1057-2007 Digitizing Waveform Recorders William B. Boyer 1, Thomas E. Linnenbrink 2, Jerome Blair 3, 1 Chair, Subcommittee on Digital Waveform Recorders Sandia National Laboratories

More information

Radiation-hard ASICs for Optical Data Transmission in the ATLAS Pixel Detector

Radiation-hard ASICs for Optical Data Transmission in the ATLAS Pixel Detector Radiation-hard ASICs for Optical Data Transmission in the ATLAS Pixel Detector P. D. Jackson 1, K.E. Arms, K.K. Gan, M. Johnson, H. Kagan, A. Rahimi, C. Rush, S. Smith, R. Ter-Antonian, M.M. Zoeller Department

More information

Radiation-hard/high-speed data transmission using optical links

Radiation-hard/high-speed data transmission using optical links Radiation-hard/high-speed data transmission using optical links K.K. Gan a, B. Abi c, W. Fernando a, H.P. Kagan a, R.D. Kass a, M.R.M. Lebbai b, J.R. Moore a, F. Rizatdinova c, P.L. Skubic b, D.S. Smith

More information

A rad-hard 8-channel 12-bit resolution ADC for slow control applications in the LHC environment

A rad-hard 8-channel 12-bit resolution ADC for slow control applications in the LHC environment A rad-hard 8-channel 12-bit resolution ADC for slow control applications in the LHC environment G. Magazzù 1,A.Marchioro 2,P.Moreira 2 1 INFN-PISA, Via Livornese 1291 56018 S.Piero a Grado (Pisa), Italy

More information

PoS(LHCP2018)031. ATLAS Forward Proton Detector

PoS(LHCP2018)031. ATLAS Forward Proton Detector . Institut de Física d Altes Energies (IFAE) Barcelona Edifici CN UAB Campus, 08193 Bellaterra (Barcelona), Spain E-mail: cgrieco@ifae.es The purpose of the ATLAS Forward Proton (AFP) detector is to measure

More information

Module 10 : Receiver Noise and Bit Error Ratio

Module 10 : Receiver Noise and Bit Error Ratio Module 10 : Receiver Noise and Bit Error Ratio Lecture : Receiver Noise and Bit Error Ratio Objectives In this lecture you will learn the following Receiver Noise and Bit Error Ratio Shot Noise Thermal

More information

Mitigating high energy anomalous signals in the CMS barrel Electromagnetic Calorimeter

Mitigating high energy anomalous signals in the CMS barrel Electromagnetic Calorimeter Mitigating high energy anomalous signals in the CMS barrel Electromagnetic Calorimeter Summary report Ali Farzanehfar University of Southampton University of Southampton Spike mitigation May 28, 2015 1

More information

Installation, Commissioning and Performance of the CMS Electromagnetic Calorimeter (ECAL) Electronics

Installation, Commissioning and Performance of the CMS Electromagnetic Calorimeter (ECAL) Electronics Installation, Commissioning and Performance of the CMS Electromagnetic Calorimeter (ECAL) Electronics How to compose a very very large jigsaw-puzzle CMS ECAL Sept. 17th, 2008 Nicolo Cartiglia, INFN, Turin,

More information

Neutron testing of the ISL70417SEH hardened quad operational amplifier

Neutron testing of the ISL70417SEH hardened quad operational amplifier Neutron testing of the ISL7417SEH hardened quad operational amplifier Nick van Vonno Intersil Corporation 5 April 213 Revision 1 Table of Contents 1. Introduction 2. Part Description 3. Test Description

More information

9-Bit, 30 MSPS ADC AD9049 REV. 0. Figure 1. Typical Connections FUNCTIONAL BLOCK DIAGRAM

9-Bit, 30 MSPS ADC AD9049 REV. 0. Figure 1. Typical Connections FUNCTIONAL BLOCK DIAGRAM a FEATURES Low Power: 00 mw On-Chip T/H, Reference Single +5 V Power Supply Operation Selectable 5 V or V Logic I/O Wide Dynamic Performance APPLICATIONS Digital Communications Professional Video Medical

More information

WIRELESS TRANSCEIVER ARCHITECTURE

WIRELESS TRANSCEIVER ARCHITECTURE WIRELESS TRANSCEIVER ARCHITECTURE BRIDGING RF AND DIGITAL COMMUNICATIONS Pierre Baudin Wiley Contents Preface List of Abbreviations Nomenclature xiii xvii xxi Part I BETWEEN MAXWELL AND SHANNON 1 The Digital

More information

Physics Experiment N -17. Lifetime of Cosmic Ray Muons with On-Line Data Acquisition on a Computer

Physics Experiment N -17. Lifetime of Cosmic Ray Muons with On-Line Data Acquisition on a Computer Introduction Physics 410-510 Experiment N -17 Lifetime of Cosmic Ray Muons with On-Line Data Acquisition on a Computer The experiment is designed to teach the techniques of particle detection using scintillation

More information

10-Bit, 40 MSPS/60 MSPS A/D Converter AD9050 REV. B. Figure 1. Typical Connections FUNCTIONAL BLOCK DIAGRAM

10-Bit, 40 MSPS/60 MSPS A/D Converter AD9050 REV. B. Figure 1. Typical Connections FUNCTIONAL BLOCK DIAGRAM a FEATURES Low Power: 1 mw @ 0 MSPS, mw @ 0 MSPS On-Chip T/H, Reference Single + V Power Supply Operation Selectable V or V Logic I/O SNR: db Minimum at MHz w/0 MSPS APPLICATIONS Medical Imaging Instrumentation

More information

Versatile transceiver production and quality assurance

Versatile transceiver production and quality assurance Journal of Instrumentation OPEN ACCESS Versatile transceiver production and quality assurance To cite this article: L. Olantera et al Related content - Temperature characterization of versatile transceivers

More information

STUDY OF THE RADIATION HARDNESS OF VCSEL AND PIN ARRAYS

STUDY OF THE RADIATION HARDNESS OF VCSEL AND PIN ARRAYS STUDY OF THE RADIATION HARDNESS OF VCSEL AND PIN ARRAYS K.K. GAN, W. FERNANDO, H.P. KAGAN, R.D. KASS, A. LAW, A. RAU, D.S. SMITH Department of Physics, The Ohio State University, Columbus, OH 43210, USA

More information

Design and Implementation of an Ultra-high Speed Data Acquisition System for HRRATI

Design and Implementation of an Ultra-high Speed Data Acquisition System for HRRATI Design and Implementation of an Ultra-high Speed Data Acquisition System for HRRATI Bi Xin bixin@sia.cn Du Jinsong jsdu@sia.cn Fan Wei fanwei@sia.cn Abstract - Data Acquisition System (DAS) is a fundamental

More information

MMA Memo 190: A System Design for the MMA. This report is concerned with the MMA receiving system and is based upon discussions of

MMA Memo 190: A System Design for the MMA. This report is concerned with the MMA receiving system and is based upon discussions of MMA Memo 190: A System Design for the MMA A. R. Thompson November 6, 1997 This report is concerned with the MMA receiving system and is based upon discussions of the MMA systems group. The part of the

More information

Module 12 : System Degradation and Power Penalty

Module 12 : System Degradation and Power Penalty Module 12 : System Degradation and Power Penalty Lecture : System Degradation and Power Penalty Objectives In this lecture you will learn the following Degradation during Propagation Modal Noise Dispersion

More information

Module 1: Introduction to Experimental Techniques Lecture 2: Sources of error. The Lecture Contains: Sources of Error in Measurement

Module 1: Introduction to Experimental Techniques Lecture 2: Sources of error. The Lecture Contains: Sources of Error in Measurement The Lecture Contains: Sources of Error in Measurement Signal-To-Noise Ratio Analog-to-Digital Conversion of Measurement Data A/D Conversion Digitalization Errors due to A/D Conversion file:///g /optical_measurement/lecture2/2_1.htm[5/7/2012

More information

A VCO-based analog-to-digital converter with secondorder sigma-delta noise shaping

A VCO-based analog-to-digital converter with secondorder sigma-delta noise shaping A VCO-based analog-to-digital converter with secondorder sigma-delta noise shaping The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters.

More information

Scintillators as an external trigger for cathode strip chambers

Scintillators as an external trigger for cathode strip chambers Scintillators as an external trigger for cathode strip chambers J. A. Muñoz Department of Physics, Princeton University, Princeton, NJ 08544 An external trigger was set up to test cathode strip chambers

More information

Test bench for evaluation of radiation hardness in Application Specific Integrated Circuits

Test bench for evaluation of radiation hardness in Application Specific Integrated Circuits SHEP 2016 Workshop on Sensors and High Energy Physics Test bench for evaluation of radiation hardness in Application Specific Integrated Circuits Vlad Mihai PLĂCINTĂ 1,3 Lucian Nicolae COJOCARIU 1,2 1.

More information

PWO Crystal ECAL. Ren-yuan Zhu California Institute of Technology May 19 th US CMS Collaboration Meeting, May 19, 2001 Ren-yuan Zhu, Caltech

PWO Crystal ECAL. Ren-yuan Zhu California Institute of Technology May 19 th US CMS Collaboration Meeting, May 19, 2001 Ren-yuan Zhu, Caltech PWO Crystal ECAL Ren-yuan Zhu California Institute of Technology May 19 th 2001 1 The Calorimeter Supermodule 36 supermodules in barrel, 4 Dees in endcaps. 1700 crystals/supermodule, 4000 crystals/dee

More information

Initial Results from a Cryogenic Proton Irradiation of a p-channel CCD

Initial Results from a Cryogenic Proton Irradiation of a p-channel CCD Centre for Electronic Imaging Initial Results from a Cryogenic Proton Irradiation of a p-channel CCD Jason Gow Daniel Wood, David Hall, Ben Dryer, Simeon Barber, Andrew Holland and Neil Murray Jason P.

More information

Characterisation of the VELO High Voltage System

Characterisation of the VELO High Voltage System Characterisation of the VELO High Voltage System Public Note Reference: LHCb-2008-009 Created on: July 18, 2008 Prepared by: Barinjaka Rakotomiaramanana a, Chris Parkes a, Lars Eklund a *Corresponding

More information

Test results on 60 MeV proton beam at CYCLONE - UCL Performed on CAEN HV prototype module A June 2001 Introduction

Test results on 60 MeV proton beam at CYCLONE - UCL Performed on CAEN HV prototype module A June 2001 Introduction Test results on 60 MeV proton beam at CYCLONE - UCL Performed on CAEN HV prototype module A877 27-28 June 2001 (M. De Giorgi, M. Verlato INFN Padova, G. Passuello CAEN spa) Introduction The test performed

More information

KLauS4: A Multi-Channel SiPM Charge Readout ASIC in 0.18 µm UMC CMOS Technology

KLauS4: A Multi-Channel SiPM Charge Readout ASIC in 0.18 µm UMC CMOS Technology 1 KLauS: A Multi-Channel SiPM Charge Readout ASIC in 0.18 µm UMC CMOS Technology Z. Yuan, K. Briggl, H. Chen, Y. Munwes, W. Shen, V. Stankova, and H.-C. Schultz-Coulon Kirchhoff Institut für Physik, Heidelberg

More information

arxiv:physics/ v1 [physics.ins-det] 19 Oct 2001

arxiv:physics/ v1 [physics.ins-det] 19 Oct 2001 arxiv:physics/0110054v1 [physics.ins-det] 19 Oct 2001 Performance of the triple-gem detector with optimized 2-D readout in high intensity hadron beam. A.Bondar, A.Buzulutskov, L.Shekhtman, A.Sokolov, A.Vasiljev

More information

A Modular Readout System For A Small Liquid Argon TPC Carl Bromberg, Dan Edmunds Michigan State University

A Modular Readout System For A Small Liquid Argon TPC Carl Bromberg, Dan Edmunds Michigan State University A Modular Readout System For A Small Liquid Argon TPC Carl Bromberg, Dan Edmunds Michigan State University Abstract A dual-fet preamplifier and a multi-channel waveform digitizer form the basis of a modular

More information

Product Range Electronic Units

Product Range Electronic Units Pyramid Technical Consultants, Inc. 1050 Waltham Street Suite 200 Lexington, MA 02421 TEL: +1 781 402-1700 TEL (UK): +44 1273 492001 FAX: (781) 402-1750 EMAIL: SUPPORT@PTCUSA.COM Product Range Electronic

More information

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators. Milestone Report

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators. Milestone Report AIDA-2020-MS15 AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators Milestone Report Design specifications of test stations for irradiated silicon sensors and LHC oriented front-end

More information

Total dose testing of the IS-1825ASRH Dual Output PWM

Total dose testing of the IS-1825ASRH Dual Output PWM Total dose testing of the IS-1825ASRH Dual Output PWM Nick van Vonno Intersil Corporation Revision 0 October 2010 Revision 1 June 2012 Table of Contents 1. Introduction 2. Reference Documents 3. Part Description

More information

High granularity scintillating fiber trackers based on Silicon Photomultiplier

High granularity scintillating fiber trackers based on Silicon Photomultiplier High granularity scintillating fiber trackers based on Silicon Photomultiplier A. Papa Paul Scherrer Institut, Villigen, Switzerland E-mail: angela.papa@psi.ch Istituto Nazionale di Fisica Nucleare Sez.

More information

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland Available on CMS information server CMS NOTE 1997/084 The Compact Muon Solenoid Experiment CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland 29 August 1997 Muon Track Reconstruction Efficiency

More information

Rad hard test of Caen HV prototype A877 for MDT and TGC performed on the CYCLONE proton beam

Rad hard test of Caen HV prototype A877 for MDT and TGC performed on the CYCLONE proton beam Muon Note June 9, 2003 Rad hard test of Caen HV prototype A877 for MDT and TGC performed on the CYCLONE proton beam G. Iuvino, A. Lanza, P. Novelli*, W. Vandelli & Istituto Nazionale di Fisica Nucleare,

More information

Theoretical Analysis of Random-Modulation Continuous Wave LIDAR

Theoretical Analysis of Random-Modulation Continuous Wave LIDAR Theoretical Analysis of Random-Modulation Continuous Wave LIDAR Enrique GONZÁLEZ, Santiago AGUILERA, Antonio PEREZ-SERRANO, Mariafernanda VILERA, José Manuel G. TIJERO and Ignacio ESQUIVIAS Departamento

More information

Semiconductor Detector Systems

Semiconductor Detector Systems Semiconductor Detector Systems Helmuth Spieler Physics Division, Lawrence Berkeley National Laboratory OXFORD UNIVERSITY PRESS ix CONTENTS 1 Detector systems overview 1 1.1 Sensor 2 1.2 Preamplifier 3

More information

Radiation hardness and precision timing study of Silicon Detectors for the CMS High Granularity Calorimeter (HGC)

Radiation hardness and precision timing study of Silicon Detectors for the CMS High Granularity Calorimeter (HGC) Radiation hardness and precision timing study of Silicon Detectors for the CMS High Granularity Calorimeter (HGC) Esteban Currás1,2, Marcos Fernández2, Christian Gallrapp1, Marcello Mannelli1, Michael

More information

The LUCID-2 Detector RICHARD SOLUK, UNIVERSITY OF ALBERTA FOR THE ATLAS- LUCID GROUP

The LUCID-2 Detector RICHARD SOLUK, UNIVERSITY OF ALBERTA FOR THE ATLAS- LUCID GROUP The LUCID-2 Detector RICHARD SOLUK, UNIVERSITY OF ALBERTA FOR THE ATLAS- LUCID GROUP LUCID (LUminosity Cerenkov Integrating Detector) LUCID LUCID LUCID is the only dedicated luminosity monitor in ATLAS

More information

MAROC: Multi-Anode ReadOut Chip for MaPMTs

MAROC: Multi-Anode ReadOut Chip for MaPMTs Author manuscript, published in "2006 IEEE Nuclear Science Symposium, Medical Imaging Conference, and 15th International Room 2006 IEEE Nuclear Science Symposium Conference Temperature Record Semiconductor

More information

Understanding the Properties of Gallium Implanted LGAD Timing Detectors

Understanding the Properties of Gallium Implanted LGAD Timing Detectors Understanding the Properties of Gallium Implanted LGAD Timing Detectors Arifin Luthfi Maulana 1 and Stefan Guindon 2 1 Institut Teknologi Bandung, Bandung, Indonesia 2 CERN, Geneva, Switzerland Corresponding

More information

ATLAS Pixel Opto-Electronics

ATLAS Pixel Opto-Electronics ATLAS Pixel Opto-Electronics K.E. Arms, K.K. Gan, P. Jackson, M. Johnson, H. Kagan, R. Kass, A.M. Rahimi, C. Rush, S. Smith, R. Ter-Antonian, M.M. Zoeller Department of Physics, The Ohio State University,

More information

Signal Simulations for. Double-sided Silicon Strip Detectors. J. Leslie, A. Seiden. Santa Cruz Institute for Particle Physics

Signal Simulations for. Double-sided Silicon Strip Detectors. J. Leslie, A. Seiden. Santa Cruz Institute for Particle Physics SCIPP 92/61 Signal Simulations for Double-sided Silicon Strip Detectors J. Leslie, A. Seiden Santa Cruz Institute for Particle Physics University of California, Santa Cruz, CA 964 Y. Unno KEK, National

More information

The domino sampling chip: a 1.2 GHz waveform sampling CMOS chip

The domino sampling chip: a 1.2 GHz waveform sampling CMOS chip Nuclear Instruments and Methods in Physics Research A 420 (1999) 264 269 The domino sampling chip: a 1.2 GHz waveform sampling CMOS chip Christian Brönnimann *, Roland Horisberger, Roger Schnyder Swiss

More information

EMC Immunity studies for front-end electronics in high-energy physics experiments

EMC Immunity studies for front-end electronics in high-energy physics experiments EMC Immunity studies for front-end electronics in high-energy physics experiments F. Arteche*, C. Rivetta**, *CERN,1211 Geneve 23 Switzerland, **FERMILAB, P.O Box 0 MS341, Batavia IL 510 USA. e-mail: fernando.arteche@cern.ch,

More information

Development of Radiation-Hard ASICs for the ATLAS Phase-1 Liquid Argon Calorimeter Readout Electronics Upgrade

Development of Radiation-Hard ASICs for the ATLAS Phase-1 Liquid Argon Calorimeter Readout Electronics Upgrade Development of Radiation-Hard ASICs for the ATLAS Phase-1 Liquid Argon Calorimeter Readout Electronics Upgrade Tim Andeen*, Jaroslav BAN, Nancy BISHOP, Gustaaf BROOIJMANS, Alex EMERMAN,Ines OCHOA, John

More information

Wideband, High Output Current, Fast Settling Op Amp AD842

Wideband, High Output Current, Fast Settling Op Amp AD842 a FEATURES AC PERFORMAE Gain Bandwidth Product: 8 MHz (Gain = 2) Fast Settling: ns to.1% for a V Step Slew Rate: 375 V/ s Stable at Gains of 2 or Greater Full Power Bandwidth: 6. MHz for V p-p DC PERFORMAE

More information

THE DEVELOPEMENT OF THE CAFE-P/CAFE-M BIPOLAR CHIPS FOR THE ATLAS SEMICONDUCTOR TRACKER

THE DEVELOPEMENT OF THE CAFE-P/CAFE-M BIPOLAR CHIPS FOR THE ATLAS SEMICONDUCTOR TRACKER THE DEVELOPEMENT OF THE CAFE-P/CAFE-M BIPOLAR CHIPS FOR THE ATLAS SEMICONDUCTOR TRACKER T. Dubbs, (email: Dubbs@SCIPP.ucsc.edu), D. Dorfan, A. Grillo, E. Spencer, A. Seiden, M. Ullan Institute For Particle

More information

arxiv:physics/ v2 [physics.ins-det] 29 Sep 2005

arxiv:physics/ v2 [physics.ins-det] 29 Sep 2005 arxiv:physics/0509233v2 [physics.ins-det] 29 Sep 2005 Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter V.A. Batarin a, J. Butler b, A.M. Davidenko a,

More information

This paper describes the main design considerations and features of the SVT, and it presents preliminary noise results obtained when the detectors wer

This paper describes the main design considerations and features of the SVT, and it presents preliminary noise results obtained when the detectors wer The BaBar Silicon Vertex Tracker Jerey D. Richman 1 Physics Department, University of California, Santa Barbara, CA 93106 Abstract The BaBar Silicon Vertex Tracker is a ve-layer, double-sided silicon-strip

More information

PCM BIT SYNCHRONIZATION TO AN Eb/No THRESHOLD OF -20 db

PCM BIT SYNCHRONIZATION TO AN Eb/No THRESHOLD OF -20 db PCM BIT SYNCHRONIZATION TO AN Eb/No THRESHOLD OF -20 db Item Type text; Proceedings Authors Schroeder, Gene F. Publisher International Foundation for Telemetering Journal International Telemetering Conference

More information

Normalized ADC output (arb. units) 1. γ + diode 2. p + CsI. 3. α + CsI 4. γ + CsI. Particle ID window

Normalized ADC output (arb. units) 1. γ + diode 2. p + CsI. 3. α + CsI 4. γ + CsI. Particle ID window Particle Identication in CsI(Tl) Using Digital Pulse Shape Analysis W.Skulski a;1 and M.Momayezi a a X-Ray Instrumentation Associates, 845 Central Av., Newark, CA 9456, USA Abstract We developed particle

More information

781/ /

781/ / 781/329-47 781/461-3113 SPECIFICATIONS DC SPECIFICATIONS J Parameter Min Typ Max Units SAMPLING CHARACTERISTICS Acquisition Time 5 V Step to.1% 25 375 ns 5 V Step to.1% 2 35 ns Small Signal Bandwidth 15

More information

Noise Characteristics Of The KPiX ASIC Readout Chip

Noise Characteristics Of The KPiX ASIC Readout Chip Noise Characteristics Of The KPiX ASIC Readout Chip Cabrillo College Stanford Linear Accelerator Center What Is The ILC The International Linear Collider is an e- e+ collider Will operate at 500GeV with

More information

Real Time Jitter Analysis

Real Time Jitter Analysis Real Time Jitter Analysis Agenda ı Background on jitter measurements Definition Measurement types: parametric, graphical ı Jitter noise floor ı Statistical analysis of jitter Jitter structure Jitter PDF

More information

Application of avalanche photodiodes as a readout for scintillator tile-fiber systems

Application of avalanche photodiodes as a readout for scintillator tile-fiber systems Application of avalanche photodiodes as a readout for scintillator tile-fiber systems C. Cheshkov a, G. Georgiev b, E. Gouchtchine c,l.litov a, I. Mandjoukov a, V. Spassov d a Faculty of Physics, Sofia

More information

Downloaded from 1

Downloaded from  1 VII SEMESTER FINAL EXAMINATION-2004 Attempt ALL questions. Q. [1] How does Digital communication System differ from Analog systems? Draw functional block diagram of DCS and explain the significance of

More information

Nonuniform multi level crossing for signal reconstruction

Nonuniform multi level crossing for signal reconstruction 6 Nonuniform multi level crossing for signal reconstruction 6.1 Introduction In recent years, there has been considerable interest in level crossing algorithms for sampling continuous time signals. Driven

More information

Signal Reconstruction of the ATLAS Hadronic Tile Calorimeter: implementation and performance

Signal Reconstruction of the ATLAS Hadronic Tile Calorimeter: implementation and performance Signal Reconstruction of the ATLAS Hadronic Tile Calorimeter: implementation and performance G. Usai (on behalf of the ATLAS Tile Calorimeter group) University of Texas at Arlington E-mail: giulio.usai@cern.ch

More information

Irradiation Measurements of the Hitachi H8S/2357 MCU.

Irradiation Measurements of the Hitachi H8S/2357 MCU. Irradiation Measurements of the Hitachi H8S/2357 MCU. A. Ferrando 1, C.F. Figueroa 2, J.M. Luque 1, A. Molinero 1, J.J. Navarrete 1, J.C. Oller 1 1 CIEMAT, Avda Complutense 22, 28040 Madrid, Spain 2 IFCA,

More information

CHAPTER. delta-sigma modulators 1.0

CHAPTER. delta-sigma modulators 1.0 CHAPTER 1 CHAPTER Conventional delta-sigma modulators 1.0 This Chapter presents the traditional first- and second-order DSM. The main sources for non-ideal operation are described together with some commonly

More information

APPLICATION NOTE. Atmel AVR127: Understanding ADC Parameters. Atmel 8-bit Microcontroller. Features. Introduction

APPLICATION NOTE. Atmel AVR127: Understanding ADC Parameters. Atmel 8-bit Microcontroller. Features. Introduction APPLICATION NOTE Atmel AVR127: Understanding ADC Parameters Atmel 8-bit Microcontroller Features Getting introduced to ADC concepts Understanding various ADC parameters Understanding the effect of ADC

More information

PMF the front end electronic for the ALFA detector

PMF the front end electronic for the ALFA detector PMF the front end electronic for the ALFA detector P. Barrillon, S. Blin, C. Cheikali, D. Cuisy, M. Gaspard, D. Fournier, M. Heller, W. Iwanski, B. Lavigne, C. De La Taille, et al. To cite this version:

More information

RF Comparator XT06 DELIVERABLES. Datasheet GDSII database Customer support

RF Comparator XT06 DELIVERABLES. Datasheet GDSII database Customer support RF Comparator XT06 DATA SHEET FEATURES FUNCTIONAL BLOCK DIAGRAM Single-supply operation: 3 V to 5 V 4 ns propagation delay at 5 V supply voltage Up to 150 MHz input Latch function HIGHLIGHTS Low input

More information

Both single and double sided silicon detectors of dierent shapes and strips conguration, including prototypes. and wedge). These detectors, and other

Both single and double sided silicon detectors of dierent shapes and strips conguration, including prototypes. and wedge). These detectors, and other Silicon Microstrip Detectors for the CMS experiment at LHC C. Civinini a a INFN sez. di Firenze, Lgo. E. Fermi 2, I-25 Firenze, Italy CMS Collaboration During the last few years a large number of Silicon

More information

GROUND MOTION IN THE INTERACTION. ensured that the final focus quadrupoles on both. rms amplitudes higher than some fraction of the

GROUND MOTION IN THE INTERACTION. ensured that the final focus quadrupoles on both. rms amplitudes higher than some fraction of the GROUND MOTION IN THE INTERACTION REGION C.Montag, DESY Abstract Ground motion and according quadrupole vibration is of great importance for all Linear Collider schemes currently under study, since these

More information

A DSP IMPLEMENTED DIGITAL FM MULTIPLEXING SYSTEM

A DSP IMPLEMENTED DIGITAL FM MULTIPLEXING SYSTEM A DSP IMPLEMENTED DIGITAL FM MULTIPLEXING SYSTEM Item Type text; Proceedings Authors Rosenthal, Glenn K. Publisher International Foundation for Telemetering Journal International Telemetering Conference

More information

Optical Readout and Control Systems for the CMS Tracker

Optical Readout and Control Systems for the CMS Tracker This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this

More information

OPTIMIZATION OF CRYSTALS FOR APPLICATIONS IN DUAL-READOUT CALORIMETRY. Gabriella Gaudio INFN Pavia on behalf of the Dream Collaboration

OPTIMIZATION OF CRYSTALS FOR APPLICATIONS IN DUAL-READOUT CALORIMETRY. Gabriella Gaudio INFN Pavia on behalf of the Dream Collaboration OPTIMIZATION OF CRYSTALS FOR APPLICATIONS IN DUAL-READOUT CALORIMETRY Gabriella Gaudio INFN Pavia on behalf of the Dream Collaboration 1 Dual Readout Method Addresses the limiting factors of the resolution

More information

Some Studies on ILC Calorimetry

Some Studies on ILC Calorimetry Some Studies on ILC Calorimetry M. Benyamna, C. Carlogan, P. Gay, S. Manen, F. Morisseau, L. Royer (LPC-Clermont) & Y. Gao, H. Gong, Z. Yang (Tsinghua Univ.) Topics of the collaboration - Algorithm for

More information

Beam Condition Monitors and a Luminometer Based on Diamond Sensors

Beam Condition Monitors and a Luminometer Based on Diamond Sensors Beam Condition Monitors and a Luminometer Based on Diamond Sensors Wolfgang Lange, DESY Zeuthen and CMS BRIL group Beam Condition Monitors and a Luminometer Based on Diamond Sensors INSTR14 in Novosibirsk,

More information

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland Available on CMS information server CMS CR -2017/349 The Compact Muon Solenoid Experiment Conference Report Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland 09 October 2017 (v4, 10 October 2017)

More information