MICRO ELECTROSTATIC ACTUATION OF A SILICON DIAPHRAGM

Size: px
Start display at page:

Download "MICRO ELECTROSTATIC ACTUATION OF A SILICON DIAPHRAGM"

Transcription

1 MICRO ELECTROSTATIC ACTUATION OF A SILICON DIAPHRAGM A Thesis presented to the Faculty of California Polytechnic State University, San Luis Obispo In Partial Fulfillment Of the Requirements for the Degree Master of Science in Biomedical Engineering by Matthew W. Samples June 2015

2 2015 Matthew W. Samples ALL RIGHTS RESERVED ii

3 COMMITTEE MEMBERSHIP TITLE: AUTHOR: Micro Electrostatic Actuation of a Silicon Diaphragm Matthew W. Samples DATE SUBMITTED: June 2015 COMMITTEE CHAIR: COMMITTEE MEMBER: COMMITTEE MEMBER: Richard Savage, Ph.D. Biomedical Engineering Department Chair David Clague, Ph.D. Associate Professor of Biomedical Engineering Hans Mayer, MS Lecturer of Biomedical Engineering iii

4 ABSTRACT Micro Electrostatic Actuation of a Silicon Diaphragm Matthew W. Samples There are a number of applications, from hearing aids to microfluidic pumps, which utilize micro-scale actuating diaphragms. These MEMS (micro-electromechanical system) devices can be actuated by electrostatic forces, which utilize an induced electric field to pull two charged plates towards one another. Such devices were fabricated and electrostatic actuation of the diaphragms was performed to analyze its viability as a micro-speaker. The long-term performance of such products requires adequate diaphragm deflection to create audible pressure waves with relatively low maximum stresses to ensure a high cycle fatigue life. With these requirements, initial calculations and FEA (finite element analysis) were performed to establish the optimal square diaphragm side length combined with an attainable gap between electrodes to achieve an audible response. Optical and acoustic testing was then performed on 4, 5, and 7 mm side length square diaphragms with 10 μm thickness and a 70 μm electrode gap. For the 5 mm device and a 300 V applied potential, deflection was calculated to be 4.12 μm theoretically and 3.82 μm using FEA, although deflections based on optical test data averaged 30.53μm under DC conditions. The DAQ used for optical testing was extremely limiting due to its fastest sampling interval of 89 milliseconds, so this testing was performed at 2 and 5 Hz. Although the 7 mm device generated audible noise at 300 V and 2 khz when the observer was within approximately 6 inches of the device, acoustic testing with a microphone placed 1 inch from the device did not yield any definitive results. iv

5 ACKNOWLEDGMENTS A number of individuals contributed insight, prior work, advice, and support throughout the past year of work on this project. I would like to thank my advisor, Dr. Savage, for his guidance throughout the project. I thank Dr. Savage and Hans Mayer for keeping the microfabrication lab and its equipment operational for the duration of the project. Also, I thank Ross Gregoriev for his contribution of the MEMS driver and for assisting with its implementation. Evan Cate has made the valuable contribution of silicon diaphragms of various sizes that enabled this project in the first place. Finally, I would like to thank my parents for their encouragement and financial support throughout the past five years of college. v

6 TABLE OF CONTENTS Page LIST OF TABLES... viii LIST OF FIGURES... x SECTION 1. BACKGROUND... 1 Keywords Introduction Electrostatic Actuation of Parallel Plates Acoustic Response of a Parallel Plate Actuator Previous Thesis Work at Cal Poly Project Scope Potential Applications of a Micro-Speaker...12 SECTION 2. DEVICE DESIGN Process Overview Diaphragm Mechanics Pull-in Voltage Breakdown Voltage Diaphragm Frequency Response...17 SECTION 3. FINITE ELEMENT MODELING Summary Model Development Mesh Development Analysis Mesh Convergence Results Discussion Conclusion...33 SECTION 4. FABRICATION Overview Physical Vapor Deposition Wire Connection Device spacer Final Device Assembly...43 vi

7 SECTION 5. DEVICE CHARACTERIZATION Overview MEMS Driver PSD Calibration Optical Characterization Test Bed Sampling Rate Limitations Optical Testing Schema Optical Testing Results Analysis of Optical Test Results Acoustic Response Testing Conclusions...77 SECTION 6. RECOMMENDATIONS FOR FUTURE WORK Diaphragms DAQ Test Bed MEMS Driver Program Data Filtering Finite Element Modelling...83 REFERENCES...84 APPENDICES...87 Appendix I. Theoretical Electrostatics Calculations...87 Appendix II. Finite Element Modelling...88 Appendix III. Optical Testing Data...91 vii

8 LIST OF TABLES Page Table 1: Acoustic powers and SLPs for each diaphragm size Table 2: List of material parameters used for diaphragm calculations Table 3: Theoretical resonant frequencies of each available diaphragm size Table 4: Material properties used for silver and silicon Table 5: Mesh convergence study results for the full 5mm x 5mm model Table 6: Stress and displacement summary for abbreviated 5mm side length models under 260V conditions Table 7: Paired resonant frequency modes for the full and quarter model Table 8: Results from higher pressure (81.21 Pa) application on a 5mm x 5mm diaphragm quarter-model Table 9: Direct comparison of applicable FEA and hand calculation results Table 10: Torr CrC-150 and Denton V physical vapor deposition parameters Table 11: Resistance measurements used for diaphragm RC time constant calculations Table 12: Thickness values for double sided Kapton Tape obtained by 2 part profilometry method Table 13: The testing plan for all devices under dynamic loading Table 14: The testing plan for all devices under static loading conditions Table 15: Oscillation results immediately, 30 seconds, and 60 seconds after powering of 4 mm devices tested at 2 and 5 Hz, 260 V Table 16: Oscillation results immediately, 30 seconds, and 60 seconds after powering of 5 mm devices tested at 2 and 5 Hz, 260 V Table 17: Oscillation results immediately after powering the 7 mm devices at 2 and 5 Hz, 260 V viii

9 Table 18: Calculated initial diaphragm deflection during DC testing at 300 V Table 19: Paired t-tests were performed for both 5 and 7 mm devices to compare deflections at 260 and 300 V for each ix

10 LIST OF FIGURES Page Figure 1: SP80 Pressure sensor diagram... 4 Figure 2: Representation of the balance of mechanical and electrostatic forces on a parallel plate electrostatic actuator... 5 Figure 3 (a): A family of curves dependent on voltage applied show the electrostatic force on a parallel plate actuator, while the red line shows the linear relationship between displacement and mechanical restoring force. (b) Example of the highest applied voltage possible before V pull-in is reached, as seen by the tangent relationship between the electrostatic force curve and the mechanical restoring force line... 6 Figure 4: Range of human hearing can be seen as a function of frequency Figure 5: A table displaying the sound pressure levels and intensities of various noises...10 Figure 6 (a): SOI wafer as received prior to diaphragm fabrication with a 10 μm device layer, 6 μm buried oxide, and 400 μm handle side. (b) Photolithography mask used for diaphragm fabrication with red corresponding to 4mm side length, green being 5mm, and blue being 7mm Figure 7: SolidWorks Exploded view of base electrode, double sided tape, and silicon diaphragm...21 Figure 8: Magnified view showing the 10 micron thick silicon diaphragm with 3000 angstrom silver layer...22 Figure 9: A view in Abaqus of the fixed edge boundary conditions and uniform pressure loading conditions on the diaphragm Figure 10: Displacement convergence of the 5mm x 5mm diaphragm model x

11 Figure 11: Static 2.5 mm x 2.5 mm quarter-model stress results under periodic loading at frequency 261 Hz Figure 12: Dynamic quarter-model stress results at frequency 5564 Hz Figure 13: The sputtering process as it occurs in the Denton V sputtering system in the Cal Poly microfabrication lab...35 Figure 14 (a): Laser cut sputtering masks made from 1/8 ABS and ¼ acrylic. (b) Pyrex slide with a Cr then Au layer deposited as an electrode Figure 15: One gold sputtered and one chromium then gold sputtered Pyrex slide which have both undergone identical peel-off testing. The gold on chromium layer (right) displays good adhesion Figure 16: Continuity was established by taking resistance measurements between the base electrode and end of the epoxied wire...39 Figure 17: Profilometer output when directly measuring thickness of double sided tape...42 Figure 18: 5mm device 1 seen post fabrication Figure 19: GUI of the LabView program that controls the MEMS driver Figure 20: PSD Calibration test setup using a laser mounted on a precision linear stage to translate a laser across the PSD surface Figure 21: Channel 301 displays Voltage changes associated with horizontal translation of the laser across the PSD surface Figure 22: Complete testing setup for collection of PSD output during diaphragm actuation Figure 23: SolidWorks assembly of the testing setup with the AOI θ referring to the angle between the vertical and the HeNe laser beam Figure 24: Simplified figure used for calculating diaphragm deflection based on AOI and laser translation along PSD surface xi

12 Figure 25: Idealized plot of the change in PSD voltage from non-actuated baseline values as a function of horizontal distance across the DUT during AC actuation Figure 26: Diagram showing how the laser responds to device actuation based on the laser s point of incidence along the central horizontal axis of the diaphragm Figure 27: The HeNe laser is centered on the diaphragm using the horizontal and vertical fine adjustment knobs of the mounting assembly Figure 28: Demonstration of aliasing where the dashed line is the false lower frequency component being reconstructed from the solid line signal...54 Figure 29 (a): Full minute and 10 seconds of data collected for 7 mm device 2 at 300 V 2 Hz. (b) Expanded view of first 20 seconds of data collection. (c) Expanded view of initial actuation data with a square outlining 4 oscillations in a 2 second period, which validates the 2Hz driving frequency was achieved mechanically Figure 30 (a): 7mm device 2 data from testing at 260 V AC 5 Hz. (b) Expanded view of the data from (a) showing 5 peaks and troughs in the first second of actuation, validating that 5 Hz was achieved mechanically Figure 31: Oscillation amplitudes over time for 4 mm devices tested at 260 V for 1 minute (device number is denoted by D# and replicate by R#) Figure 32: Oscillation amplitudes over time for 5 mm devices tested at 260 V for 1 minute (device number is denoted by D# and replicate by R#)...63 Figure 33: Boxplot of distances traveled by the laser on the PSD as a result of oscillating diaphragm deflections. Data is broken up by applied voltage and device side length, including 2 4 mm, 2 5 mm, and 1 7 mm devices xii

13 Figure 34 (a): DC stability testing of 5 mm device 1 at 300 V with split lines between each 1 minute test segment, which were each 15 minutes apart. (b) Expanded view of the first 2 seconds of deflection demonstrating a gradual mechanical response Figure 35 (a): DC stability testing of 7 mm device 1 at 300 V. (b) Expanded view of the diaphragm response at the time of actuation Figure 36: ANOVA readout from Minitab for analysis of AC characterization results Figure 37: Minitab output for a paired t-test comparing laser deflection from 4 mm diaphragms operated at both 260 and 300 V Figure 38: DC testing results plotted and shown with the figure demonstrating laser redirection based on point of incidence on a deflected diaphragm Figure 39: The inside of the acoustic foam fixture with the Vernier microphone inserted Figure 40: Acoustic testing setup including the DUT connected to the MEMS driver and the acoustic foam fixture lifted from where it sits over the DUT Figure 41: Plot of ambient noise in the acoustic foam fixture Figure 42: Offset pressure generated by PZT disc operating at 1 VPP and 2 khz with a 10 khz sampling rate Figure 43: Plot of 7 mm device 2 actuating at 2000 Hz with 300 V applied Figure 44: An example setup that can be used in laser-doppler vibrometry...82 xiii

14 SECTION 1. BACKGROUND Keywords Abaqus FEA: A finite element analysis program that provides the capability of performing theoretically accurate mechanical analysis of specified loading conditions on a components or system. Data Acquisition Unit (DAQ): A device or system set up to measure electrical or physical phenomenon. Diaphragm: A thin film component of a MEMS device, typically composed of silicon, designed to deform under induced stresses Electrostatic Force: An effect in which a force is generated between two electrically charged surfaces. Two oppositely charged surfaces in close proximity with one another experience an attractive force, while two surfaces with the same charge experiences a repulsive force. MEMS: A micro-electromechanical system is the name given to a broad category of devices with electrical and mechanical components that have micron-scale (10-6 meters) dimensions. PSD: A position sensitive detector uses a voltage differential across its surface both horizontally and vertically to precisely track in both axes the location of incident light on its surface. Sound Pressure Level (SPL): The difference between a local pressure wave and atmospheric pressure. This is used in assessing the loudness of an acoustic output. 1

15 1.1 Introduction MEMS technology has revolutionized a wide range of products in the past few decades thanks to the advances made in microfabrication methods. The benefits of microfabrication have been seen in devices like transistors. The number of transistors capable of being fabricated per square inch, in accordance with Moore s Law, has successfully been on track for doubling every 1-2 years since the invention of the integrated circuit in Transducers, many of which are now MEMS devices, have seen the same breakthroughs in the form of miniaturization while maintaining accuracy thanks to microfabrication. Microfabrication techniques provide the ability to fabricate millions of identical components on a single chip with the same effort as is required to create a single component. The capability of fabricating these devices en masse on a micro-scale has opened up a range of possible applications for them as products like strain gauges, pressure sensors, and accelerometers. Within the field of transducers, devices which convert energy of one form to another (e.g. electrical to mechanical), there are two categories- sensors and actuators. A sensor is a transducer which typically converts forms of energy into electrical signals, such as a microphone that translates the mechanical vibrations created by sound pressure waves into an electrical response. An actuator is a transducer that typically does the opposite, such as a speaker to which electrical signals are input and audio output is produced through mechanical vibrations. In a traditional speaker, electrical input is converted to mechanical vibrations using electromagnetic actuation, whereas in the field of MEMS the same actuation results can be achieved on a smaller scale with high accuracy by a number of different means. Electromagnetic, electrostatic, piezoelectric, and thermo-pneumatic actuation can be achieved on the micro scale due to the unique thin film surface effects present at that scale. 2

16 1.2 Electrostatic Actuation of Parallel Plates The structure of an electrostatically actuated MEMS speaker typically involves a parallel plate capacitor setup in which a conductive thin film is fixed a small distance, typically 10 to 100 μm,- from a base electrode. When a capacitor is placed in a circuit with a voltage source, charge buildup occurs between the two electrodes until the point of discharge. This charge buildup can be utilized in MEMS devices to perform work in the form of electrostatic actuation so long as at least one of the parallel plates is a thin film with weak enough mechanical restoring force to be overcome by the electrostatic force. Coulomb s law provides the basis of mathematically determining electrostatic interactions between charged particles, which can then be applied to the electrostatic interactions between plates. Coulomb s law is stated in Equation 1.1, which relates particle charge and distance between them to the electrostatic force created: F electrostatic = k q 1 q 2 r where k is Coulomb s constant (8.988x10 9 Nm 2 C -2 ), q 1 and q 2 are charge magnitudes, and r is a scalar distance between the charged points. When moving from point to planar surface electrostatic effects, there are three factors which influence the electric field. These including electrode gap, voltage, and electrode area. Equations 1.2 through 1.5 show the development of the governing equation of electrostatics as applied to charged plates. F electrostatic = E field ρ 1.2 E field = V z 1.3 3

17 ρ = C V = ε ε 0 A V z 1.3 F electrostatic = ε ε 0 A V z 2 where ρ is charge, E field is the strength of the electric field, V is the applied potential, A is the area of plate overlap, z is the distance between the plates, and ε 0 is the permittivity of free space (ε 0 =8.85*10-12 F/m). ε can be neglected when solving for most MEMS devices as it is the dielectric constant of the material (air) between capacitor plates, and ε air =1. As can be seen from this equation, a larger overlapping plate area will increase electrostatic effects, but not as significantly as applied voltage and electrode gap. The desired magnitude of electrode displacement due to electrostatic forces varies greatly based on the application of the MEMS device. A pressure sensor (essentially a microphone) can typically have a smaller deflection than a micro-speaker to achieve the desired output due to the high accuracy of piezoresistive strain gauges in MEMS devices. One such device can is the SP80 Pressure Sensor, seen in Figure 1, which utilizes doped regions of the silicon diaphragm at high strain points to generate an accurate reading. 2 Figure 1: SP80 Pressure sensor diagram. 2 4

18 A micro-speaker, on the other hand, must translate electrical input into mechanical actuation on a magnitude that generates an audible sound pressure level. This corresponds to an electrostatic force that triggers a physical response capable of overcoming the mechanical restoring force of the parallel plate attachment points to its bulk supporting structure. This is diagramed in Figure 2, which sums up the relationship between mechanical restoring force and electrostatic force on a given parallel plate. Note that the mechanical restoring force of the parallel plate support structure is essentially a spring force and therefore elicits a linear elastomechanical response, while the electrostatic force versus displacement relationship is exponential. Figure 2: Representation of the balance of mechanical and electrostatic forces on a parallel plate electrostatic actuator. 3 The non-linear relationship of electrostatic force versus parallel plate displacement stems from the redistribution of charge on the surface of the actuating electrode as it moves closer to the fixed electrode. This can potentially lead to an issue of snap-down in the instance of the electrodes becoming overly-charged and flexing too close towards each other. An example of being on the edge of such an occurrence can be seen in Figure 3 (b), wherein the linear mechanical restoring force lies tangential to 5

19 the electrostatic force curve. The intersection point of the two curves marks the equilibrium displacement of the plate. As can be seen in Figure 3(a), increasing voltage moves the electrostatic force curve to the right, meaning that at any voltage greater than that seen in Figure 3(b) snap-down will occur. The minimum potential required to achieve this phenomenon is referred to as the pull-in voltage (V pull-in ), and while certain applications such as electrostatic switches do utilize V pull-in, a micro-speaker typically does not. a b Figure 3 (a): A family of curves dependent on voltage applied show the electrostatic force on a parallel plate actuator, while the red line shows the linear relationship between displacement and mechanical restoring force. (b) Example of the highest applied voltage possible before V pull-in is reached, as seen by the tangent relationship between the electrostatic force curve and the mechanical restoring force line. 4 Equation 1.5 sums the potential energy in a parallel plate electrostatic actuator, which can be used to establish the deflection distance and V pull-in at which snap-down is triggered. PE = kz2 ε 0 A V z 1.5 6

20 The second derivative of this equation is set to 0 to establish the required condition for mechanical equilibrium: δ 2 (PE) δz 2 = k ε 0 A V2 (d z) 3 = V 2 = k (d z)3 ε 0 A V pull in = 8 k d 3 27 ε 0 A where d is the original distance between the parallel plates and k is the spring constant of the diaphragm. Equation 1.7 can also be substituted into the first derivative of Equation 1.5, seen in Equation 1.9 below, to determine that the maximum deflection before snap-down occurs is one third of the initial electrode gap, d. kz = 1 2 ε 0 A z pull in = d 3 V2 = k(d z) (d z) Equations 1.8 and 1.10 provide critical stability criteria for effective electrostatic operation. 5 It is therefore important to avoid these values with a factor of safety to avoid snap-down, which limits the work (force*displacement) capacity of an electrostatic actuator. 1.3 Acoustic Response of a Parallel Plate Actuator In order to assess the acoustic response of a micro-speaker, the basic principles of what makes a sound must be explored. The human body perceives pitch, which is a means of differentiating sound frequencies. A sound frequency is the rate at which compression waves arrive at a fixed location. Another key measure of sound is the intensity, which is commonly expressed as a measure of decibels. The sound pressure level is a deviation from atmospheric pressure caused by the sound waves as they 7

21 propagate through a material. Sound pressure level can be calculated as 10 times the logarithm of the ratio of two sound intensities, or using the ambient pressure (P ref ) and generated pressure (P) as seen in Equation P L p = 20 log P ref Alternatively, an acoustic power approach can be taken. The power that a square parallel plate capacitor can generate can be approximated using Equation 1.12, which was developed for a disc-shaped radiator. 7 P acoustic = 0.25 d 4 f 4 2 x peak 1.12 In this equation, d is the radiator diameter (on in this case, diaphragm side length), f is the actuation frequency, and x peak is the maximum radiator displacement at that frequency. The displaced portion of a square diaphragm takes on roughly the same discshape as the radiator that Equation 1.12 was developed for, so the results should provide a reasonably accurate value for acoustic power. This power can then be applied to Equation 1.13 to find the sound pressure level L db achieved by an actuator: P acoustic = 10 L db π x peak 1.13 where y is the distance from the sound radiator. Applying the maximum MEMS driver potential of 300V AC at 2000 Hz, the acoustic power and sound intensity can be calculated for 4, 5, and 7 mm side length diaphragms at a distance of 1 inch (length of the ear canal) from the actuator. These results can be seen in Table Hz was used as the driving signal because as seen in Figure 4, this is approximately the largest hearing threshold range and 200 Hz was used as the other end of the spectrum because this is a common frequency of the human voice. 7 8

22 Table 1: Acoustic powers and SLPs for each diaphragm size. Diaphragm Size P acoustic (m 6 /s 4 ) at f=200 Hz P acoustic (m 6 /s 4 ) at f=200 Hz L db (db) at f=200 Hz L db (db) At f=2000 Hz 4mm 2.92E E mm 4.25E E mm 6.27E E Figure 4: Range of human hearing can be seen as a function of frequency. 7 One can compare the expected sound pressure levels calculated in the previous table to the table seen in Figure 5 and find that only at high frequencies can any of the diaphragms generate a sound pressure level comparable to that of conversational speech. Despite the setback of a limited frequency range at which the devices are potentially audible, they are capable of being tested at lower frequencies with sensitive microphones. 9

23 Figure 5: A table displaying the sound pressure levels and intensities of various noises Previous Thesis Work at Cal Poly A range of diaphragm sizes have been fabricated using multiple methods in past Cal Poly thesis projects. Most recently, success has been seen by Evan Cate in fabrication of square silicon diaphragms of 10 μm thickness with side lengths of 4mm, 5mm, and 7mm in the Cal Poly Microfabrication Lab. This fabrication was performed using a silicon-on-insulator (SOI) wafer of the dimensions seen in Figure 6 (a) and a photolithography mask seen in Figure 6 (b). SOI wafers have been the preferred means of diaphragm fabrication in most recent attempts due to the built-in etch stop that mitigates the warping issues that were inherent with the previously attempted boron doped silicon etch stops. 10

24 Figure 6 (a): SOI wafer as received prior to diaphragm fabrication with a 10 μm device layer, 6 μm buried oxide, and 400 μm handle side. (b) Photolithography mask used for diaphragm fabrication with red corresponding to 4mm side length, green being 5mm, and blue being 7mm. 10 Characterization of the diaphragms fabricated in past projects was performed, although this has typically been done using a micro-force displacement system (MFDS) both with and without a DC voltage applied across the electrodes. The MFDS, while fairly reliable at measuring the mechanical response of a diaphragm on the nanometer scale, has its limits. Once a diaphragm is actuated by electrostatic means, the mechanical force that the MFDS prober tip must apply to locate the new surface location further deflects the diaphragm. This leaves the exact deflection distance from electrostatic forces indeterminate. It has been concluded that electrostatic actuation has occurred on the larger (5+ mm) devices charged at 300 VDC based on lower MFDS force readings at a constant displacement, but no quantification of displacement was performed Project Scope The goal of this project is to design, fabricate, and assess the actuation capabilities of an electrostatically actuated MEMS diaphragm. Silicon diaphragms were fabricated in numerous past thesis projects at Cal Poly, which most recently resulted in Evan Cate creating 10 μm thick square diaphragms with side lengths of 4mm, 5mm, and 11

25 7mm. 10 While square diaphragm microfabrication methods have been developed in the Cal Poly Microfabrication Lab, electrostatic actuation of these diaphragms has been a point of questionable success. Characterization of an electrostatically actuated parallel plate device that has been fabricated in the on-campus Microfabrication Lab is the end goal of this project. The scope has been limited to characterizing actuation of an already fabricated diaphragm (therefore 4mm, 5mm, or 7mm side length square diaphragm) that, as calculated, has the potential to be applied as a micro-speaker. This means the diaphragm should be capable of producing an audible sound pressure level through electrostatic actuation. Device characterization criteria include definitive identification of diaphragm actuation, determination of the capacitive time response, dynamic cycling response, estimation of device actuation, and sound pressure level achieved during device actuation. Characterization is to be carried out for all available diaphragm sizes, including devices of 4mm, 5mm, and 7mm side length. 1.6 Potential Applications of a Micro-Speaker Micro-speakers have existed for years, but an omnipresent challenge associated with them is finding new ways to shrink their size further, achieve better sound quality, and package them in a more compact form all at a lower cost. In the US alone, nearly 314 in 1000 people over 65 suffer from hearing loss, and 80% of those would benefit from using hearing aids but choose not to use them. 12 A major factor in refusing treatment with hearing aids is the social stigma associated with wearing them and reluctance to treat presbycusis, the loss of hearing with age. While hearing aids have been undergoing steady improvements since the introduction of digital hearing aids in 1996, patients continue to seek out longer-lasting battery life, better directionality, and lower costs, background noise, and acoustic feedback

26 Of the two forms of hearing loss, conductive and sensorineural, hearing aids of the microphone-amplifier-loudspeaker variety can be beneficial to those with conductive hearing loss. In order to overcome the stigma of wearing hearing aids, completely-in-thecanal (CIC) hearing aids are a necessity, but these provide many challenges for improving quality due to the 0.7 inch diameter and 1 inch length size constraints in order to fit in the ear canal. Under such constraints, electromagnetically actuated MEMS loudspeakers have been seen to exhibit the most effective operating conditions (7 μm displacements, equivalent to 120-dB SPL at 1 khz) due to the relatively low power consumption compared to electrostatic actuation

27 SECTION 2. DEVICE DESIGN 2.1 Process Overview The design process for creation of a capacitive micro-speaker began with the establishment of design requirements. It was known that diaphragm deflections must be maximized in order to achieve adequate pressure waves from the device for potential application as a micro-speaker. Constraining factors such as V pull-in, diaphragm side length, electrode spacing, and material selection were considered during the design process. Knowing the available diaphragm side lengths fabricated by Evan Cate, the mechanics of a diaphragm undergoing electrostatic actuation could be analyzed to assess device viability in a high frequency actuation application. 2.2 Diaphragm Mechanics The mechanics of a square diaphragm were analyzed to ensure adequate deflections could be achieved, stresses were within a safe operating range, and pull-in voltages were not reached. A square film of a given side length is preferable because under identical operating conditions it can achieve greater deflection than a circular film with a diameter equal to the square s side length, meaning that the footprint to deflection ratio of a square diaphragm is more favorable than that of a circle. Square diaphragms also have the greatest pressure induced stresses compared to rectangular and circular diaphragms, which leads to greater precision in its deflections. 13 Some assumptions were made to simplify the calculations associated with electrostatically actuated diaphragm mechanics. These include the square shape being clamped on all four edges to a rigid support structure, the diaphragm thickness being significantly smaller than the side length (t=a/10, a being side length) so the structure is considered to be loaded in full bending, and the forces present are tangential to the surface of the diaphragm. 14

28 Additionally, the material was considered homogeneous and isotropic, and the inherent membrane stresses from fabrication were neglected. As can be noted from Equation 1.4, the electrostatic force exerted on a parallel plate actuator is primarily dependent on the device side length and electrode gap. Assuming uniform loading, the electrostatic force can be divided by the area of the actuator to find an equivalent electrostatic pressure on the diaphragm. P electrostatic = ε ε 0 V 2 z This pressure can then be applied to the mathematical models which approximate a square diaphragm s maximum deflection Z center and maximum stress σ max. Z center = a4 P E t σ max = a2 P t In Equations 2.2 and 2.3, a refers to diaphragm side length and t to its thickness. As intuition suggests, the maximum displacement of a uniformly loaded square diaphragm is at its center, hence z center is the critical deflection used in device characterization. The maximum stress σ max, on the other hand, is located at the center of the edges on a square diaphragm. The material constants used in the previously mentioned calculations can be seen in Table 2 below. Single crystal silicon, the material used to fabricate the diaphragms being tested, is highly anisotropic due to its face-centered cubic diamond unit cell structure. This means the Young s Modulus E for the (110) plane must be used for calculations because that is the plane perpendicular to the applied electrostatic load. 15

29 Table 2: List of material parameters used for diaphragm calculations Material Young s Modulus Poisson s Ratio Yield Strength E (110) (Pa) σ y (Pa) Silicon 170E E9 The calculated electrostatic force and resultant deflection values for multiple electrode gaps, applied voltages, and diaphragm side lengths are tabulated in Appendix I. Calculations were performed for electrode gaps between 70 and 100 μm due to ease of fabrication and voltages between 260 and 300 V due to the limitations of the MEMS driver. Key results were then used based on a 70 μm electrode gap, 260 and 300 V, and 5 mm side length to move forward with finite element modelling of the device with the most likelihood of successfully producing an acoustic output. 2.3 Pull-in Voltage Equation 1.10 from Section 1.2 states that snap down is likely to occur when the device is actuated to one third of the initial electrode gap distance. This constraint was considered after deflection calculations were run to establish that within the 300V operating range capability in the microfabrication lab, a 5mm by 5mm diaphragm with a 70 μm electrode gap does not achieve its pull-in voltage. The theoretical deflection of said device at 300V is 4.12 μm with a maximum stress of 6.26 MPa. Pull-in is predicted at approximately 23 μm and the yield strength of single crystal silicon is 7 GPa, therefore the diaphragm is clear to operate with a factor of safety of 5.58 with regard to pull-in. 14 Due to the extreme resilience of silicon undergoing cyclic loading, there is little concern with material fatigue effects under these conditions. 2.4 Breakdown Voltage When working with the high voltages inherent in performing electrostatic operations, the breakdown voltage must be avoided. According to Paschen s law, pressure and gap length are the determining factors of breakdown voltage, which is the 16

30 voltage required to create an electric arc between two electrodes. 15 The lower the density of atoms in an electrode gap, the higher the voltage required to trigger an avalanche breakdown. This relationship can be seen below in Equation 2.4, in which A and B are experimentally determined values dependent on the gas medium, p is the operating pressure, and d is the electrode gap distance. In the case of air, A is 15 cm -1 *Torr -1 and B is 365 V*Torr*cm -1. V b = A p d ln(p d)+b Diaphragm Frequency Response Multiple factors contribute to maximum operating frequency of an electrostatically actuated device. When designing a parallel plate actuator, the capacitive charging and mechanical response must be considered as potential operating frequency limiters. The actuator operates like a capacitor in that a surface charge is established over time, the properties of which can be characterized by the parameters seen in Equations τ = R C 2.5 C = ε r ε 0 A d 2.6 f c = 1 2 π τ 2.7 In Equations 2.4 and 2.5, R is resistance, C is capacitance, ε r is the dielectric constant of air (~1), ε 0 is the electric constant (8.854x10-12 F/m), A is the overlapping plate area, and d is the distance between plates. These parameters establish the capacitive time constant τ at which point the capacitor has charged to 63.2% or discharged to 36.8% of its full capacity. If a device is operated at its cutoff frequency, defined by Equation 2.7, and losses from the mechanical response are neglected, it can only achieve a small fraction of its total deflection due to the small portion of the full charge capacity that is 17

31 reached. In order to achieve deflections consistent with theoretical calculations for a capacitive actuator, the transient response of the RC circuit must be reached. This is approximately 5τ, at which point 95% of the source voltage is seen across the capacitor. For this reason, it is of critical importance to minimize resistance and capacitance values of the actuator in order to achieve high frequency response rates. Calculation of the device capacitances could be done before fabrication, but the resistance in the circuit leading up to the capacitor could only be determined after key fabrication steps had been performed. The cutoff frequency was therefore not determined until the devices were ready for testing. The mechanical response of the capacitor is another issue that is only partially dependent on its time dependent charging. The time delay of an actuators mechanical response is considerably larger than its capacitive time response for an efficient electrostatic device. 16 Inherent stresses in the actuating material play a large role in its mechanical response to stimulus, so on a device-by-device basis this could be quite variable depending on the consistency of the fabrication procedure. What can be predetermined mathematically is the resonant frequency of a square diaphragm based on the Young s modulus E (170 GPa), side length a, thickness t (10 μm), material density ρ (2330 kg/m 3 ), and Poisson s ratio v (0.23). 14 Equation 2.8 can be used to calculate the resonant angular velocity ω r, while Equation 2.9 can convert that to the resonant frequency. Table 3 displays the resonant frequencies calculated for the 3 sizes of diaphragms characterized in this project. E ω r = ( t 12 ρ (1 v 2 ) 4 a2) 2.8 f r = w r 2 π

32 Table 3: Theoretical resonant frequencies of each available diaphragm size Diaphragm Side ω r (rad/s) f r (Hz) Length (mm) Whether or not these resonant frequencies can be realized is a factor of the cutoff frequency from capacitive charging and the subsequent mechanical response times for each device. In the case of a micro-speaker for use in a hearing aid, the resonant frequency should be avoided to mitigate sound distortion and maintain consistent functionality. For characterization purposes and attempting to generate acoustic output from such a device, being able to drive it at its resonant frequency is a desirable capability. 19

33 SECTION 3. FINITE ELEMENT MODELING 3.1 Summary A finite element model was developed to characterize the physical response of electrostatically actuated MEMS diaphragms. This analysis was performed in Abaqus/CAE 6.11 on a 5 mm by 5 mm silicon diaphragm with a uniform thickness of 10 μm and a 3000 angstrom silver layer deposited on top, as seen in the SolidWorks model in Figure 7. A two part model was created for each analysis in which a silver layer composed of shell elements was fixed to the surface of the solid hexagonal silicon elements and a pressure mimicking the corresponding theoretical electrostatic response was applied. The deflection and maximum principle stress of a 5mm x 5mm diaphragm under static loads were determined to be 2.86 μm and 4.04 MPa, respectively. These static results, which are slightly below the calculated values for an electrostatically actuated silicon diaphragm without an attached electrode, are supportive of further development of this sized diaphragm. The dynamic FEA results support the operation of a 5mm x 5mm MEMS diaphragm below the Hz resonant frequency for maximum efficiency and predictable acoustic output. 20

34 5mm x 5mm, 10 micron thick diaphragm Bottom Electrode with trace 70 micron Kapton tape Figure 7: SolidWorks exploded view of base electrode, double sided tape, and silicon diaphragm 3.2 Model Development A 5mm x 5mm x 10 μm square, silicon MEMS diaphragm was modeled and analyzed with a 3000 angstrom layer of silver attached to it (which acts as an electrode). The diaphragm loading is characteristic of the conditions that can be imparted on it in the Cal Poly Microfabrication Lab (i.e. maximum 300 V output from MEMS driver). Static and dynamic analyses were run with the electrostatically generated forces for 260V and 300V signals with a 70 μm gap between the charged plates, and a linear perturbation step was run to find the resonant frequencies. As seen below in Figure 8, the assembly was modeled in SolidWorks, but it was determined that the models would have to be created in Abaqus to overcome the zero volume elements inherent in a meshed solid material as thin as the silver layer. The entire diaphragm and electrode were modeled first to generate a solution reasonably close to the calculations performed in the project proposal. The boundary conditions 21

35 consisted of 0 displacements on all axes, which were applied along all edges of the silicon diaphragm. This corresponds to where the diaphragm connects to the main block of silicon it is fabricated from. The silver layer is its own part in Abaqus, so it was positioned on top of the silicon diaphragm. A tie boundary condition was then applied between the bottom face of the silver electrode and the top face of the silicon so the two would react together when the load is applied. This mimics the constraint of the silver electrode that is sputtered onto the silicon diaphragm. Finally, a pressure of magnitude Pa was applied to the top face of the electrode. A view of the boundary conditions in Abaqus can be seen in Figure 9. The pressure used was calculated using Equation 3.1, seen below, by substituting in the force seen on the diaphragm under the conditions of a 260 V signal applied and a 70 micron distance between electrodes (see table in Appendix I). All material properties were applied to their corresponding parts as they are defined in Table 4 below. P = F A 3.1 Silver Silicon Figure 8: Magnified view showing the 10 micron thick silicon diaphragm with 3000 angstrom silver layer 22

36 Table 4: Material properties used for silver and silicon Material Density (kg/m 3 ) Young s Modulus (Pa) Poisson s Ratio Silicon E Silver E Figure 9: A view in Abaqus of the fixed edge boundary conditions and uniform pressure loading conditions on the diaphragm. Once the full model was verified based on its maximum stress and displacement values by comparing them to the preliminary calculations, the model was simplified using its symmetry to cut down memory requirements and calculation time. The quarter-model had the same zero displacement boundary conditions applied to the two outer edges 23

37 and was fixed in the direction perpendicular to the other remaining inside edges (see Appendix II). Once the quarter-model was verified by comparing its results to those of the full model, the analysis progressed to using a dynamic step on the simplified model. 3.3 Mesh Development A number of different meshing attempts were made before the final convergent mesh was decided upon. Initially, two shell sectioned parts were constructed with 100 shell elements each due to the thickness of the parts being significantly smaller than the length or width of the parts. Complications were encountered when applying the tie boundary conditions to faces of each part because each one is displayed as a zero thickness plane, causing the two to deform incorrectly and seemingly overlap. Next, two solid parts were imported from SolidWorks. A coarse mesh was attempted using both quadratic hexagonal (brick) and tetrahedral (pyramid) elements. Errors regarding zero volume elements prevented this job from running- every element comprising the silver layer was too thin for accurate use in the matrix calculations. This necessitated the switch to shell elements for the silver part, while the silicon part maintained a solid section constructed in Abaqus. Quadratic elements were used to capture the bending of the elements more accurately since the strains present in the model are relatively high in the direction of the thickness. Throughout the trial and error of the meshing process the quality of the elements being used improved steadily in terms of minimizing the aspect ratio and avoiding extreme distortions of individual elements. When a 10x10x3 edge seeding was used on the silicon part, the aspect ratio for 300 elements exceeded 100 to 1. This explains the inaccurate results seen later as the first data point in the mesh convergence process. Once the mesh became more refined, all minimum/maximum angles and aspect ratio criteria were met. 24

38 3.4 Analysis In the Model Development section, the static analysis was introduced. In this static analysis, both a constant and periodic load was analyzed. The periodic load was characterized by a circular frequency ω=2*π*f, with f=261 (a middle-c frequency that was first arbitrarily attempted in this project), initial amplitude of 1 at time 0, and constants A and B defined as 0 and 1. These constants were determined from the Fourier series of the amplitude a, seen in Equation 3.2. a = A 0 + N n=1 [A n cosnω(t t 0 ) + B n sinnω(t t 0 )] for t t The next model development step was using a steady state dynamics, directstep analysis rather than static. The importance of the dynamic step is to examine the effects of a range of frequencies on diaphragm actuation. During characterization, the diaphragms can be subjected to a wide range of frequencies to evaluate their peak performance range, thus knowing their response at a range of frequencies is beneficial. The frequency response was analyzed on the simplified model between 20 Hz and 10,000 Hz to cover the lower half of the range of human hearing, which is more frequently utilized during normal activity. Finally, a linear perturbation-frequency step was used to evaluate the resonant frequencies of the device. The input for this analysis supports boundary conditions only for its calculations (as opposed to previous analyses using applied load as well). The quarter-model with the minimum convergent mesh parameters was again used to run this job. Throughout the stepwise analysis of this model a number of warnings were present. To summarize, the following warnings were consistent in each step: Adjustment was specified for tie pairs but no major adjustments were made 25

39 There is a zero moment everywhere in the model based on default criterion Multiple Tie dependent nodes have specified boundary conditions. These conditions will be transferred to associated tie independent nodes Boundary conditions are specified on inactive dof of x nodes. These warnings were not a concern because most of them are stating that the desired effects of the tie condition were placed on the part, and the zero moment is acceptable because the edges do not have a zero rotation boundary condition on them. This means there are no reaction moments nor were any moment loads on it, therefore the warning is not a concern. These analysis results, which are very close to the predicted values, verify that these warnings are inconsequential. 3.5 Mesh Convergence Once it was established that the elements would be quadratic, quadrilateral shell elements for the silver part and quadratic, hexagonal 3D stress elements for the silicon, a mesh convergence study was performed on the full model. Seeding was performed by edge on both parts of the model, resulting in a mesh with 1 element along the thickness of the silver part and 4 on the silicon part. A high stress node at the mid-point on the left edge of the silicon part was selected for checking convergence (Appendix II), while the node at the very center of the top plane of the silicon part was used for the displacement mesh convergence check (Appendix II). The mesh convergence study outlined in Table 5 shows the number of elements, degrees of freedom, max principle stress and displacement for each mesh attempt on the model. Figure 10 displays the convergence plot of the displacement results from the study, while the stress based mesh convergence can be found in Appendix II. 26

40 Displacement (m) Table 5: Mesh convergence study results for the full 5mm x 5mm model Number of Degrees of Displacement (m) Stress S11 (Pa) Elements Freedom Silver: E E6 Silicon:300 Silver: E E6 Silicon:1200 Silver: E E6 Silicon:2700 Silver: E E6 Silicon:4800 Silver: E E6 Silicon: E E E E E E E E E E Degrees of Freedom Figure 10: Displacement convergence of the 5mm x 5mm diaphragm model. 3.6 Results The final number of elements used in the full model was 12500, which corresponds to degrees of freedom, although for an approximation that minimizes computing time without sacrificing resolution, 3600 elements with degrees of freedom could be used. These mesh characteristics can be seen with their corresponding maximum principle stress and displacement results from the static analysis in Table 5 of the Mesh Convergence section. The results of the full finite 27

41 element analysis on the quarter-model can be seen in Table 6, which covers static, constant and static, periodic pressure loading conditions as well as a dynamic analysis for a range of frequencies. For a visualization of the lower voltage, quarter-model maximum stress results for the static, 261 Hz loading condition, see Figure 11. The equivalent dynamic model for loading frequency 4456 Hz can be found in Appendix II. Table 6: Stress and displacement summary for abbreviated 5mm side length models under 260V conditions Analysis Description Static, constant load Static, periodic load Dynamic Frequency (Hz) N/A Elements Degrees of Freedom Max Max Stress Displacement (m) (Pa) -2.87E E Hz -2.86E E E E E E E E E E E E E E E E E E E E E E5 Table 7: Paired resonant frequency modes for the full and quarter model Frequency Mode Model Frequency 1 Full Quarter Full Quarter None 3 Full Quarter None 4 Full Quarter None 5 Full Quarter Full Quarter

42 Figure 11: Static 2.5 mm x 2.5 mm quarter-model stress results under periodic loading at frequency 261 Hz. All analyses were repeated with the higher applied pressure from a 300V signal. This Pa pressure, when applied statically, periodically, and dynamically yielded the results in Table 8. For validation of the model and assurance in the dynamic and resonant frequency results, comparisons can be made between Table 6 and Table 7 s static, constant load results. For convenience, all the relevant results have been combined into Table 9 and the difference between theoretical and FEA results were calculated. 29

43 Table 8: Results from higher pressure (81.21 Pa) application on a 5mm x 5mm diaphragm quarter-model. Analysis Description Static, constant load Static, periodic load (Frame 7, step 3.5) Steady-State Dynamics Frequency (Hz) Max Displacement (m) Max Principle Stress (Pa) N/A -3.82E E6 261 Hz -3.84E E E E E E E E E E E E E E E E E E E E E E6 Table 9: Direct comparison of applicable FEA and hand calculation results. Analysis Calculation Type Theoretical FEA Result Difference (m) Result (m) (m) (Theoretical-FEA) 260V Signal Displacement (m) 3.10E E E-06 Max Stress (Pa) 4.70E6 4.14E E V Signal Displacement (m) 4.12E E E-06 Max Stress (Pa) 6.26E6 5.51E E Discussion A side by side analysis of the hand calculated (theoretical) values and the FEA values for the static, constant pressure load (seen in Table 6 of the previous section) show relatively comparable values. The discrepancies for displacements are 0.2 to 0.3 microns and the maximum stress differs by a fraction of a megapascal, with both FEA values being lower than their theoretical counterparts. These values seem close enough that the model is validated because the finite element model has a layer of silver on it 30

44 that the hand calculated values did not incorporate. The silver layer likely absorbs some of the stresses on the silicon diaphragm and decreases the deflection capabilities very slightly. Overall, the finite element model seems accurate enough based on the static results so the dynamic and frequency response results can be referenced for diaphragm experimentation in the future. In the future, the model could be more accurately recreated using the properties of gold instead of the silver used in this model, although at that scale the mechanical properties of such a film are essentially negligible. Silver was only used in this model because it was unknown that gold would be the conductive material of choice at the time. While the dynamic model reveals a lot about the mechanical tendencies of the device as the frequency of loading is increased, there are a multitude of FEA tests that could still be run. This includes a dynamic test at key frequencies of interest to determine exactly how the diaphragm responds throughout the sinusoidal loading from an AC driving signal. This could be done using an Abaqus standard (implicit) step with a time period that allows the device to get up to its full oscillating amplitude. The results for this analysis could reveal how long a diaphragm remains transient in its oscillatory amplitude before settling into its steady state conditions. Above 5000 Hz, specifically the 5280 Hz resonant frequency, results in the dynamic analysis begin to deviate from the expected. In Figure 12, the deformed quarter-model stress results show highly elevated stress levels when operating close to the resonant frequency. Past this frequency, there is a sharp drop in displacement and max stress. A likely cause for this occurrence is destructive interference of the sinusoidal loading rhythm with the harmonic frequency that the diaphragm attempts to oscillate at. The cause of the decreased displacement amplitudes between 5 and 10 khz 31

45 could be further investigated by running the aforementioned dynamic FEA analysis at specific frequencies. Figure 12: Dynamic quarter-model stress results at frequency 5564 Hz. 32

46 3.8 Conclusion The primary takeaway is that the finite element model was verified by theoretical calculations so the dynamic analysis and frequency response results can be taken into account when planning future tests of these diaphragms. The first resonant frequency mode was hit at approximately 5280 Hz- with a slight discrepancy on the exact value between the full and quarter-model. This appears to affect the performance of the device for a few hundred hertz range less than 5.28 khz and for all higher frequencies. It is therefore recommended that use of these devices remain in the lower frequency range of human hearing, between 20 Hz and 5 khz. Further dynamic analyses can be performed at specific frequencies to elaborate on the mechanical response of the device and solidify its optimal performance range. 33

47 SECTION 4. FABRICATION 4.1 Overview Parallel plate actuators of 3 different sizes- 4, 5, and 7 mm side lengths- were fabricated using 5 main steps. These included surface cleansing of the diaphragm and glass substrate, physical vapor deposition (PVD) of chromium on the glass, PVD of gold on both the glass and the diaphragm, connection of wires to the electrodes by either conductive epoxy or conductive tape, and finally, mounting of the diaphragm on the glass substrate using double-sided tape. Pairs of each size actuator were fabricated for a total of 6 devices, which were all tested for low impedance on each respective side of the insulative electrode spacers (double sided tape). 4.2 Physical Vapor Deposition Starting with a 5 mm diaphragm, a base material and electrode material were selected. Pyrex microscope slides, composed of borosilicate glass, fit the requirements for the base material as they are insulative and sturdy. A major concern with using a glass base is the adhesion capability of gold when deposited by physical vapor deposition. Physical vapor deposition, colloquially known as sputtering, is a process involving the bombardment of a target- typically a negatively charged metal disk- by positive argon ions within a vacuum chamber. Metal ions are launched off the target by the argon ion bombardment, which directs the metal ions in the general direction of the substrate being coated. In order to remedy the adhesion issues that were experienced with gold sputtered directly onto borosilicate glass, a chromium layer was sputtered onto the glass first. 34

48 Figure 13: The sputtering process as it occurs in the Denton V sputtering system in the Cal Poly microfabrication lab. 17 Prior to the physical vapor deposition process, the substrate must be freed of all organics and other contaminants. First, the Pyrex slides were wiped using a Kim-wipe with 70% IPA on it to remove large debris. The silicon diaphragms and Pyrex slides were then dipped in a Piranha bath, comprised of a 3:1 ratio of H 2 SO 4 to H 2 O 2, at 65 C for 10 minutes to remove all organic materials. Silicon readily grows an oxide layer at room temperature, so the previously fabricated diaphragms were then submerged in buffered oxide etchant (BOE) for 5 minutes to remove the surface oxide. When sputtering thin films such as electrodes, there are two common approaches for patterning. High resolution patterns typically use a thin film of photoresist which is patterned using photolithography and then acts as a sputter mask. After deposition, the photoresist can be removed to reveal a fairly high resolution pattern where the sputtered metal reached the substrate. Similarly, a thin sheet of a solid material can be cut and placed on top of the substrate during the sputtering process. As 35

49 the electrode feature being patterned does not require high feature resolution, this method is preferred due to ease of fabrication of the mask. Electrode sputtering masks, seen below in Figure 14 (a) were laser cut from 1/8 ABS plastic and ¼ acrylic to observe the directional effects of sputtering on relatively large feature sizes. First, the Pyrex slides and masks were placed in the Torr CrC-150 sputtering system to deposit the adhesive chromium layer on the glass using the process parameters outlined in Table 10. The slides and masks were then transferred to the Denton V sputtering machine to deposit a gold layer on top of the chromium. Profilometer measurements of these electrodes were taken, but the variability of the measurement system is fairly large for this application. It was established that the total electrode thickness is between 100 and 300 nanometers, which is small enough to be negligible with respect to changes in electrostatic force generation. Table 10: Torr CrC-150 and Denton V physical vapor deposition parameters. Machine Sputtered Pumpdown Base Power Sputter Time Material time Pressure Setting Torr CrC- 150 Chromium 30 min 4 mt 99 W 30 sec pre/1 min sputter Denton V Gold 120 min 1.9 μt 48 ma 5 min 36

50 a 7 mm 7 mm b Figure 14 (a): Laser cut sputtering masks made from 1/8 ABS and ¼ acrylic. (b) Pyrex slide with a Cr then Au layer deposited as an electrode. Knowing that the next fabrication step would be adhesion of a wire or other conductor to connect the electrode to the MEMS driver, the durability of the metal layer was tested. This involved performing a peel-off test in which a piece of tape was applied to the sputtered surface, pressed down evenly, and removed. Success was qualitatively assessed, with the goal being little to no loss of gold from the glass slide. Complete peeloff was observed on glass slides coated solely with gold, while little to no peel-off was observed when chromium was deposited as an adhesive layer between the gold and glass. These results are displayed in Figure

51 4.3 Wire Connection Figure 15: One gold sputtered and one chromium then gold sputtered Pyrex slide which have both undergone identical peel-off testing. The gold on chromium layer (right) displays good adhesion. Continuity was ensured across the length of the electrode and trace, including the connection to the MEMS driver, whether that was a conductive copper tape strip or a silver epoxied wire. This was done by measuring the resistance across the electrode and trace using a Fluke ohmmeter to verify low resistances, which typically ranged from 2-4 Ω. Conductive tape had the advantage of being quickly and easily applied as well as allowing reapplication or adjustment. Silver epoxy, on the other hand, provided a rigid attachment that could be well adhered by covering both the end of the electrode trace and some of the surrounding glass. This ensured structural rigidity due to the strong connection between silver epoxy and glass absorbing any loads placed on the wire so as to not peel off the thin gold film. In the case of the conductive tape needing to be reapplied onto the electrode, new tape would need to be adhered to a new gold covered location on the diaphragm to continue to achieve low resistances measurements. 38

52 Figure 16: Continuity was established by taking resistance measurements between the base electrode and end of the epoxied wire. The fixation of the wire to the base electrode and/or the diaphragm was done using H22 EPO-TEK Silver Conductive Epoxy. This was applied by first mixing the 2 part solution in a 100:4.5 ratio of part A to part B measured by weight. A short, approximately 2 inch wire was then inserted into the epoxy where it was applied on the diaphragm or slide, and then the sub-assembly was placed in the oven to cure for 10 minutes at 120 C. The resultant connection was more than robust enough for the minimal forces encountered during component transit and device assembly, except the epoxy would peel off the gold layer from the diaphragm if bumped with much force. In order to bolster that connection s peel-off strength, the wire was silver epoxied to the silicon diaphragm 39

53 before a gold layer was deposited on top of that in order to provide conductivity between the thin film of the diaphragm and the structural silicon supports surrounding the film. In order to calculate the capacitive time constant of each electrode, the exact resistance measurements were recorded from one end of the diaphragm to the end of its attached wire or copper tape. The greater of these two measurements was then used in Equation 2.5 to determine the worst-case capacitive time constant for each device, which in turn dictates its cutoff frequency f c according to Equation 2.7. As explained in section 2.5, the time constant is multiplied by 5 before being used to determine the cutoff frequency in order to achieve full device charging and discharging. These resistance test results and corresponding time constants can be seen in Table 11. Table 11: Resistance measurements used for diaphragm RC time constant calculations Device Lead Type R 1 (Ω) R 2 (Ω) 5*τ (ns) f c (GHz) Description 4mm Device 1 Silver Epoxy mm Device 2 Copper Tape mm Device 1 Copper Tape mm Device 2 Silver Epoxy mm Device 1 Copper Tape mm Device 2 Silver Epoxy Based on these sub-nanosecond capacitive charging times and cutoff frequencies in the gigahertz range, the electrical response time of the device will not be a concern when operating within the human hearing frequency band. 4.4 Device spacer A critical feature of the electrostatically actuating diaphragm system is the electrode gap. This feature requires an electrically insulative material capable of providing a consistent distance between electrodes, which in turn allows the desired electrostatic force to be applied. In the past, use of SU-8 was attempted as a photo- 40

54 definable, patterned spacer and the thickness could be tailored to match the specified electrode gap. In many instances, the diaphragm did not adhere completely to the SU-8, which was built up from the base Pyrex slide. For both cost effectiveness and ease of fabrication, double sided tape was the primary candidate in this project as a method for fixing the diaphragms to the Pyrex slide base at the desired electrode gap distance. Kapton Tape manufactures double sided polyimide tapes that suit the application of spacing an electrostatic actuator due to being electrically insulating. The tape structure is a 1 mil polyimide film with 1.5 mil of silicone adhesive coating on each side, which totals 4 mils (101.6 μm) thickness when uncompressed. A series of measurements were performed using a profilometer to establish the compressed thickness of the double sided Kapton Tape. Initially, the double sided tape was stuck to a glass slide, the adhesive cover was removed, and the tape was directly probed with a 0.20 mg force by the profilometer stylus. This resulted in measurements of 72.2, 73.2, and 74.9 μm for the tape thickness, which was considered an adequate verification of the 70 μm electron gap used in FEA. It was noticed that the probe tip deflected into the silicone due to its viscoelastic properties even when the minimum stylus force of 0.20 mg was applied, so in order to attain a more accurate compressed tape thickness, an improved measurement technique was developed. The adhesive coating on one side of the tape was first exposed and pressed onto a Pyrex slide. With the other adhesive side of the tape still covered, the profilometer was run over the tape to attain the thickness at that point. The cover that remained on the tape for the first measurement was then removed and its thickness was measured with the profilometer. By subtracting the thickness of the adhesive coating cover from the thickness of the tape with the cover on, the thickness of the compressed tape alone was determined. Table 12 displays each thickness measurement and the calculated compressed tape thickness. 41

55 These thicknesses were averaged to find 92.0 μm is the approximate working electrode gap of the electrostatic actuators. Figure 17: Profilometer output when directly measuring thickness of double sided tape Table 12: Thickness values for double sided Kapton Tape obtained by 2 part profilometry method. Thickness of Tape + Thickness Adhesive Tape Thickness (μm) Adhesive cover (μm) Cover (μm) Acoustic advantages can also be conveyed through a flexible support structure such as double sided tape. The silicone supports can mitigate the standing waves that would be reflected from a rigid speaker frame. Research has determined that a flexural and soft device due to non-rigid supports can have an enhanced sound pressure level and reduced distortion

56 4.5 Final Device Assembly The electrostatic actuator assembly was ultimately comprised of one diaphragm, a Pyrex slide, 4 mil thick double-sided tape, and conductive tape or wire leads attached to each electrode. This was entirely hand assembled once the physical vapor deposition processes had been performed. The first 5 mm device that was fabricated and tested can be seen in Figure 18. Figure 18: 5mm device 1 seen post-fabrication. As was done throughout the fabrication process, resistance measurements were taken across the entire device. In this instance, the desired ohmmeter output was infinite resistance when measuring from one wire lead across the device to the wire attached to the opposite electrode. This is due to the insulative gap between the electrodes which causes only a tiny capacitive current (also known as leakage current) to flow through the system. The associated resistance through the system is out of range of the ohmmeter used for this measurement. If a non-infinite resistance measurement were picked up across the system, it would mean a short is present between the device and the base electrode and the voltage differential between the parallel plates is compromised. 43

57 SECTION 5. DEVICE CHARACTERIZATION 5.1 Overview The goal of this project past fabrication of a parallel plate actuator was to devise a means of characterization for such a device. In past projects, a MEMS driver has been used to drive various sized actuators while they were characterized by a mechanical contact method- either a profilometer or a customized MFDS that uses the same principles. Alternatively, this was an attempt to utilize optical and acoustic modes of characterizing similar devices. A laser was directed at the diaphragm which had a voltage applied to it, and the reflective surface of the diaphragm redirected the light to a PSD. Based on the angle of incidence of the laser on the diaphragm, the diaphragm deflection when a voltage is applied could be calculated from the PSD output. Previously, the mechanical nature of the characterization techniques limited device testing to the initial application of a DC voltage source followed by quasistatic behavior analysis. The nonphysical approach of this project opens up the possibility of dynamic analyses using the AC capability of the MEMS driver. Further attempts were made to characterize the actuators by acoustic means as well due to the potential of the actuator to generate a detectible sound pressure level. A simple microphone and data logging program were used to collect changes in the SPL created by the actuating diaphragm. 5.2 MEMS Driver The MEMS driver consists of a combination of software and hardware developed by Ross Gregoriev in a past thesis project. This driver hardware can be turned on by flipping the power switch on the rear of the unit as well as the one on the front, and then by switching on all the front switches of the driver the device will be ready to generate a signal. A LabView graphical user interface (GUI) was designed to run the driver, which can apply both AC and DC voltages from 0 to 300V. As seen in Figure 19, the GUI 44

58 provides the option of adjusting voltage amplitude, frequency, offset, and duty cycle for AC mode and DC voltage for DC mode. Testing was performed using the square wave function generator to elicit the greatest responsiveness of the diaphragms at any operating voltage. A square wave applies an impulse load to the device which gives potential for increased deflection compared to gradual sinusoidal loading. In order to configure the MEMS driver to output a square wave, the previously mentioned AC modifiers must be set, the square wave button must be clicked, and the enable output button must be clicked. For safety purposes, the applied voltage can be stopped by 3 methods: deselecting the enable output button, turning off the enable output switch on the hardware, or clicking the stop button, which shuts the whole program down. 45

59 Figure 19: GUI of the LabView program that controls the MEMS driver. 5.3 PSD Calibration The PSD used in this project tracks position by changing voltage where photons hit its surface. With light incident on its center, it registers a 0V reading from each of the channels it has been connected to on the DAQ. Position changes can then trigger +/- 10V readings from each channel, which corresponds to movement along the horizontal and vertical axes. It is supposed to come calibrated to output a 1V change for every 46

60 millimeter the incident light moves, so a test was performed to verify this. The test setup, seen in Figure 20, reflected a laser off a diaphragm and onto the PSD. The laser, mounted on a Thor Labs high precision linear stage, was then translated 5mm using the fine adjustment knob on the stage. These results, which have been plotted in Figure 21, were used to calculate the actual change in voltage for a 5mm translation along the PSD surface. In Figure 21, Channels 301 and 302 correspond to the X and Y direction on the PSD surface, respectively. By dividing the distance traveled by the change in PSD voltage output, the following correction factor was determined: 5mm V = mm V Laser incident on PSD Diaphragm used for reflection Laser Thor Labs High Precision Linear Stage Figure 20: PSD Calibration test setup using a laser mounted on a precision linear stage to translate a laser across the PSD surface. 47

61 PSD Output (V) Time (s) 301 (VDC) 302 (VDC) Figure 21: Channel 301 displays Voltage changes associated with horizontal translation of the laser across the PSD surface. This correction factor can then be multiplied by the total voltage differential for a given actuation cycle of the device to determine a more accurate laser translation distance. The corresponding error associated with this result compared to the specifications of the PSD is: 1 mm mm V V mm V 100 = 2. 73% 5.4 Optical Characterization Test Bed In order to assess the electrostatic actuation capability of the silicon diaphragms, a test setup was devised. The setup acquires data on the displacement of the diaphragm by capturing the relative change in position of the laser that is reflected off the diaphragm onto a PSD. The system is comprised of 8 components in total: a MEMS driver, a position sensitive detector, an amplifier for the PSD, a DAQ, a laser, a control box for the laser, the device under testing, and an optical breadboard. The laser is mounted on a precision angle adjustment stage, while the device under testing (DUT) and PSD are mounted on linear adjustment stages. All of these stages are mounted on 48

62 an optical breadboard to allow for precise position control. Figure 22 shows the testing system on its workbench in the microfabrication lab. KEY On-Trak PSD Amplifier Position Sensitive HeNe Laser Detector Laser Power Switch Agilent DAQ MEMS Driver DUT Figure 22: Complete testing setup for collection of PSD output during diaphragm actuation. The angle of incidence (AOI) of the laser on the diaphragm and the horizontal beam deflection picked up by the PSD were used in some simple trigonometry to calculate the deflection of the device. These values can be seen in the CAD assembly in Figure

63 Figure 23: SolidWorks assembly of the testing setup with the AOI θ referring to the angle between the vertical and the HeNe laser beam. Three major assumptions were made in order to calculate the diaphragm deflection based on PSD output: 1. the laser was centered on the diaphragm both vertically and horizontally 2. the deflected diaphragm surface on which the laser is incident lies on a plane parallel to its initial position 3. the diaphragm provides a smooth, uniformly reflective surface. Figure 24 shows the simplified test station parameters based on the aforementioned assumptions. Operating under these assumptions, a rough value for the deflection of the diaphragm at the point of incidence can be calculated using Equation

64 Figure 24: Simplified figure used for calculating diaphragm deflection based on AOI and laser translation along PSD surface. x diaphragm = δ cos (θ) 4.1 The angle of incidence θ was 49 degrees for this device characterization and system testing, simplifying the deflection of the diaphragm to: x diaphragm = δ cos(49) δ Because maximum deflection is the value of interest and it occurs at the center of the diaphragm, assumption 1 is critical to device characterization. Assumption 2 is reasonable because as seen in the FEA deflection results, the curvature of the diaphragm at the center is minimal and the PSD is able to average out the spread created by the laser hitting a slightly rounded surface. There is an extremely high aspect ratio between the diaphragm deflection distance and the side length, which theoretically minimizes the redirecting effects from the curvature of the sides and prevents the 51

65 actuated location of laser incidence on the diaphragm from being significantly offset from center. The test station was set up by a combination of visual inspection of the laser on the device surface and on-the-spot analysis of the voltage output from the PSD while an AC signal was applied to the DUT. Ideally, vertical alignment could be achieved by finding the point where the voltage output is constant on the vertical PSD channel. In reality, imperfections in the equipment holding the DUT and laser in place as well as surface defects on the DUT prevent exact vertical alignment. The precision angular adjustment dial was used to find the device s horizontal midpoint by slowly scrolling the laser across the device then visually judging when the PSD voltage output associated with the horizontal asymptote shown in Figure 25 is reached. This point symbolizes the center point because when the derivative of the change in voltage output by the PSD reaches 0, laser deflection from the angle of the deformed diaphragm has been minimized. Figure 26 helps to explain this concept further by diagramming the laser s response to device actuation along the horizontal axis. ΔVcycle (V) Distance across DUT (%) Figure 25: Idealized plot of the change in PSD voltage from non-actuated baseline values as a function of horizontal distance across the DUT during AC actuation. 52

66 Figure 26: Diagram showing how the laser responds to device actuation based on the laser s point of incidence along the central horizontal axis of the diaphragm. Figure 27: The HeNe laser is centered on the diaphragm using the horizontal and vertical fine adjustment knobs of the mounting assembly. 53

67 While this approach to finding a vertical center point first then analyzing the oscillating device data output in real time seemed feasible, excessive system noise and human error prevented this from being effectively implemented in testing. Ultimately, location of the diaphragm center points was assessed on a strictly visual basis. 5.5 Sampling Rate Limitations A number of issues arose during initial testing of the optical measurement testing setup, primarily due to the sampling rate of the DAQ. The Agilent DAQ operates using mechanical relays that seemed to be the limiting factor of sampling rate in the system. The PSD has a 15 khz sampling limit and while the DAQ software allows it to be set to a 1 millisecond sampling interval (1 khz), data collection was actually limited to an 89 millisecond sampling interval. An 89 millisecond sampling interval is an 11.2 Hz collection rate, which in itself eliminated the possibility of testing the diaphragms anywhere near their resonant frequencies, which fell between 1-5 khz. According to the Nyquist Theorem, the sampling rate must be at least twice as fast as the bandwidth of the signal in order to prevent aliasing in the analog to digital conversion process. 19 Aliasing is the phenomenon of collecting a false lower frequency component due to data acquisition being too slow. Figure 28: Demonstration of aliasing where the dashed line is the false lower frequency component being reconstructed from the solid line signal

68 In order to operate in adherence with the Nyquist Theorem, device testing must occur at 5 Hz or below in order to accurately reconstruct the correct frequency response of the device. The greater the multiplier relating the sampling frequency to the device signal the less likely the signal will be attenuated. This means 5 Hz testing may experience some attenuation depending on when actuation is triggered with respect to when the next sample is taken by the DAQ, so 2 Hz testing was also performed to ensure full resolution of device deflection. With a square wave signal powering the device, aliasing is less likely as there are two discrete voltages, 0 V and the testing voltage (260 or 300 V), and there is additional time to perform capacitive charging so the full electrostatic potential is realized. 5.6 Optical Testing Schema This section aims to congregate all previous mention of the modes of optical testing in a single location. It has been mentioned that the diaphragms will be characterized in both static and dynamic loading. This means both DC and AC signals will be applied using the MEMS driver to assess deflection patterns, frequency response, repeatability and reproducibility. Reliability, referring to the system s capability of achieving the same results twice, is greatly affected by imprecise setup procedure, which in turn affects the ability to accurately assess the repeatability of an actuator. A gage R&R study can be used to analyze the variation in a measuring system between 3 primary sources: the device under testing, the appraiser, and the equipment. 20 In this situation, a single operator was used so the appraiser variability could not be analyzed and there was not time to perform a fully randomized testing process by the time all the devices had been fabricated. For these reasons, a simplified design of experiments was 55

69 used to characterize the properties and capabilities of the diaphragms and the measurement system. Each of the devices tested underwent 3 tests at each frequency and voltage combination for a total of 12 AC tests. 2 different devices of each side length were used in hopes of establishing how consistent the performance of nearly identical devices is. The AC testing plan can be seen in Table 13, for which each of the stated tests lasts 1 minute and 10 seconds and is performed 3 times. The first 10 seconds of each test are taken with no power to the device in order to set a baseline PSD reading and to quantify the noise. All data collection was done at 89 millisecond intervals, which is the maximum frequency allowed by the DAQ. Table 13: The testing plan for all devices under dynamic loading Device Side Device Number Voltage (V) Frequency (Hz) Length (mm)

70 After dynamic testing, static testing was performed at 300 V for each of the 5 mm and 7 mm side length devices used for the previous tests. Due to the time constraints of the project and the length of time required for each static test, each device was only tested once. 4 mm side length devices were excluded from static testing due to their poor results in preliminary testing which showed a very large noise to signal ratio. A total of 4 tests were performed at 300V DC for an hour each in order to maximize device deflection and stresses, which should result in greater resolution of device stability over time. This works out to 1 test performed on each of the 2 5 mm and 7 mm devices. Should the electrostatic force slowly taper off or waver over time, the mechanical restoring force would cause a more noticeable change in deflection when the initial deflection amplitude is greater. The DC testing plan can be seen in Table 14, with each test being performed only 1 time. Over the course of the 1 hour test period, 1 minute collections were taken as the DC voltage was initially applied then again every 15 minutes. Table 14: The testing plan for all devices under static loading conditions Device Side Length (mm) Device Number Voltage (V)

71 5.7 Optical Testing Results Due to the massive amount of data collected, representative samples were taken from each test. The key parameters of the AC device deflection that required collection were the frequency, the amplitude of the oscillations, and the noise. The frequency at which devices were actuating was assessed by visual inspection of the PSD output, which can be plotted over a short time period to verify adherence to the expected output. This can be seen on the next page in Figure 29, which plots PSD output from a test of 7 mm device 1 with a 260 V AC square wave signal running at 2 Hz. By counting the local maxima and minima in a set period, the mechanical frequency response of the diaphragm can be compared to the output frequency of the MEMS driver. Figure 30 displays the actuator response of 7 mm device 2 driven at 5 Hz and 260 V. 58

72 PSD Voltage (V) PSD Voltage (V) PSD Voltage (V) Time (s) a Time (s) b Time (s) Horizontal Channel c Figure 29 (a): Full minute and 10 seconds of data collected for 7 mm device 2 at 300 V 2 Hz. (b) Expanded view of first 20 seconds of data collection. (c) Expanded view of initial actuation data with a square outlining 4 oscillations in a 2 second period, which validates the 2Hz driving frequency was achieved mechanically. 59

73 PSD Voltage (V) PSD Voltage (V) Time (s) a Time (s) b Figure 30 (a): 7mm device 2 data from testing at 260 V AC 5 Hz. (b) Expanded view of the data from (a) showing 5 peaks and troughs in the first second of actuation, validating that 5 Hz was achieved mechanically. Due to the oscillating patterns of the PSD voltage output, each data set had to be post-processed to find the local oscillation amplitudes and total deflections relative to a baseline value. In the following tables, the post-processed data is broken down by device being tested, the testing parameters, and the immediate deflection and oscillation amplitude. Additional data can be found for all devices at both AC frequencies and voltages in Appendix III. One important consideration for this data is that while it has 60

74 been converted into a distance metric, it is the distance the laser translated along the horizontal axis of the PSD surface and not the distance the diaphragm deflected. The distance the center of the diaphragm has physically deflected, which is roughly times the distance the laser traveled across the PSD, can be estimated using Equation 4.1. The immediate oscillation amplitude values are simply a calculation of the local minima subtracted from the local maxima at the beginning of device actuation. To find the immediate PSD deflection, the local maxima were subtracted from the PSD baseline voltage collected at the beginning of each test prior to device actuation. As was determined in the PSD calibration section, the laser travels mm on the surface of the PSD per volt change in output, so the voltage output was multiplied by 973 to convert it to a micron distance value. In all subsequent plots, collection point 1 refers to immediately after powering the actuator, point 2 is 30 seconds after, and point 3 is 1 minute after. Table 15: Oscillation results immediately, 30 seconds, and 60 seconds after powering of 4 mm devices tested at 2 and 5 Hz, 260 V. Device Size (mm) Device # Rep Frequency (Hz) Immediate Oscillation Amp (um) 30 Sec Oscillation Amp (um) 60 Sec Oscillation Amp (um)

75 Oscillation Amplitude (μm) mm D1 R1 2Hz 4mm D1 R2 2Hz 4mm D1 R3 2Hz 4mm D2 R1 2Hz 4mm D2 R2 2Hz 4mm D2 R3 2Hz Collection Point Figure 31: Oscillation amplitudes over time for 4 mm devices tested at 260 V for 1 minute (device number is denoted by D# and replicate by R#). Table 16: Oscillation results immediately, 30 seconds, and 60 seconds after powering of 5 mm devices tested at 2 and 5 Hz, 260 V. Device Size (mm) Device # Rep Frequency (Hz) Immediate Oscillation Amplitude (um) 30 Sec Oscillation Amp (um) 60 Sec Oscillation Amp (um)

76 Oscillation Amplitude (μm) mm D1 R1 2Hz 5mm D1 R2 2Hz 5mm D1 R3 2Hz 5mm D2 R1 2Hz 5mm D2 R2 2Hz 5mm D2 R3 2Hz Collection Point Figure 32: Oscillation amplitudes over time for 5 mm devices tested at 260 V for 1 minute (device number is denoted by D# and replicate by R#). Table 17: Oscillation results immediately after powering the 7 mm devices at 2 and 5 Hz, 260 V Device Size (mm) Device # Rep Frequency (Hz) Immediate Oscillation Amplitude (um) 30 Sec Oscillation Amp (um) 60 Sec Oscillation Amp (um) Another useful means by which the data can be visualized is by the boxplot in Figure 33. Side by side comparisons can be made between each device size, applied voltage, and their respective deflections. Results from 7 mm device 1 were excluded due to the extraordinarily large deflection measurements. It was apparent during post- 63

77 Data Deflection (µm) processing that the point of laser incidence on the diaphragm was on an angled portion of the diaphragm during its deflection, which as demonstrated in Figure 26 causes a greatly exaggerated translation of the laser on the PSD Applied Voltage mm deflection mm deflection mm deflection Figure 33: Boxplot of distances traveled by the laser on the PSD as a result of oscillating diaphragm deflections. Data is broken up by applied voltage and device side length, including 2 4 mm, 2 5 mm, and 1 7 mm devices. The DC testing can best be summarized by magnitude of initial deflection and the plots seen in the following figures. Table 18 displays the initial diaphragm deflection from each of the 5 and 7 mm devices at the 300 V DC output used for all hour-long stability tests. Figures 34 and 35 exemplify the difficulties that were encountered with discontinuous, lengthy stability testing with the current test setup. Table 18: Calculated initial diaphragm deflection during DC testing at 300 V. Device PSD Output (V) Laser Travel on PSD (µm) Calculated Diaphragm Deflection (µm) 5 mm Device mm Device mm Device mm Device

78 PSD Output (V) PSD Output (V) a Time (s) 3.72 b Time (s) Figure 34 (a): DC stability testing of 5 mm device 1 at 300 V with split lines between each 1 minute test segment, which were each 15 minutes apart. (b) Expanded view of the first 2 seconds of deflection demonstrating a gradual mechanical response. 65

79 PSD Output (V) PSD Output (V) a Time (s) b Time (s) Figure 35 (a): DC stability testing of 7 mm device 1 at 300 V. (b) Expanded view of the diaphragm response at the time of actuation. It is key to note that the deflection of the 4 and 5 mm devices were too small to visualize with the naked eye, but with the 7 mm devices the deflections could be seen at both 260 and 300 V. Additionally, the 7 mm devices responded so much more efficiently than 4 or 7 mm that the deflections could be detected over the system noise down to approximately V applied. A differentiable signal could not be attained below approximately 220 V for a 4 mm device and 180 V for a 5 mm device. 66

80 5.8 Analysis of Optical Test Results In device characterization, noise contributed to a high degree of variability in PSD output whether the tests were a minute or an hour long. For 260 V AC testing, the standard deviations of the pre-test noise ranged from to 5.98 µm and averaged µm. These numbers were then compared to the average and standard deviation of the change in oscillation amplitudes for all devices over the 1 minute AC testing period, which are and µm, respectively. The overlap in the standard deviation of the pre-test noise and the change in oscillation amplitude values suggest the two could be too similar to draw any conclusions as to whether noise or an actual change in device oscillation amplitude is causing the observed results. Also supporting the claim that the noise is causing the majority of instability in AC oscillation is the fact that oscillation amplitudes do not follow a consistently increasing or decreasing trend over time as seen by Figures 31, 32, and multiple figures in Appendix III. In order to validate this belief, a 1 sample t-test was performed in which the standard deviation of the noise was used as the hypothesized mean (µ 0 ) and the following criteria was tested: µ ΔOscillation Amp >µ 0 where µ ΔOscillation Amp is the mean oscillation amplitude. A t-value of 3.41 and p-value of were obtained, which suggests that within a 95% confidence interval, we can reject the null hypothesis. These results suggest the noise during testing is too great to resolve changes in electrostatic effects over the course of the tests performed. In other words, it can be said with 95% confidence that the variability in oscillation magnitude is less than or equal to the standard deviation of the noise, proving a reasonable degree of device actuation repeatability. 67

81 An ANOVA test was performed to verify that PSD output could be differentiated based on device size, device number, and voltage applied. In this ANOVA test, the data was blocked by replicate and interaction terms were included for the three other factors, as seen in Figure 36. Two interaction terms- interaction between applied voltage and device size and interaction between applied voltage and device number- accounted for the vast majority of variability in the data. Figure 36: ANOVA readout from Minitab for analysis of AC characterization results. Due to the complications of such a multifaceted ANOVA, comparisons were simplified into a few direct comparison t-tests. Based on the results seen in Figure 33, the 7 mm devices outperform the others in terms of achievable deflection under the same power limitations. Paired t-tests were performed between the 260 V and 300 V deflections of each sized device to determine which sized devices provide a significant 68

82 enough difference in responses for the system to resolve. For 4 mm devices, this test gives a t-value of 3.01 and a p-value of as seen in the Minitab results in Figure 37. This low p-value means the null hypothesis of equivalence can be rejected with 95% confidence and one of the displacement means is greater than the other. It is apparent from Figure 33 that the mean for 4 mm devices powered at 300V is lower than the same devices powered at 260 V, which defies the principles of electrostatics. This means the quantity of error in the current optics-based measurement system is likely too large to draw conclusions between 4 mm device deflections. Figure 37: Minitab output for a paired t-test comparing laser deflection from 4 mm diaphragms operated at both 260 and 300 V. Additional paired t-tests were performed to compare the deflections at 260 V and 300 V for 5 and 7 mm devices. Table 19 summarizes this information, in which the null hypothesis is always equivalence of means and a rejection of that hypothesis can be interpreted to mean the sample population with the larger mean is significantly different than the lesser mean within a 95% confidence interval. Table 19: Paired t-tests were performed for both 5 and 7 mm devices to compare deflections at 260 and 300 V for each. Devices compared T-Value P-Value Conclusion 5 mm Fail to Reject H 0 7 mm Reject H 0 69

83 As can be seen from Table 19, the 7 mm devices were the only ones capable of deflecting at statistically different amplitudes while complying with the expected results based on electrostatic principles. Due to noise being one of the main issues with the current system, it was closer observed to see if a root cause could be determined. The AC test results were reordered from least to greatest noise during testing so that device size, device number, time of test, and frequency could be observed for patterns. Unfortunately, the reordered data in all the aforementioned fields was highly randomized and no conclusions could be drawn. Non-tested factors must therefore be playing a role in the inaccuracy of the test setup. Speculated factors include the consistency of the HeNe laser intensity and uniformity throughout its 2 mm beam diameter and the stability of the second story location of the microfabrication lab. Changes in ambient lighting that reach the PSD could occur on some scale due to people walking by outside the microfabrication lab because the test bed is located next to a window. Vibrations can often be felt when standing in the microfabrication lab, so some degree of these vibrations undoubtedly are introduced into the system. The long-term positional drift of the PSD is also a factor in the reliability of optical testing. As can be seen in the DC testing results in Table 18, diaphragm deflections were calculated that surpass the electrode gap. There is clearly a large amount of inaccuracy with the alignment of the laser in the exact center of the diaphragm. Additionally, assumption 2 made in Section 5.1 that a circular section of the deflected diaphragm reaches an essentially flat point of peak deflection is likely incorrect. A safe assumption is the actual deflections of all devices are less than those recorded in the data section of this report, although this could very well not be the case if the test setup mimicked that of the yellow line in Figure

84 The data from Figures 34 (b) and 35 (b) shows two opposing trends upon powering of each respective device. Figure 34 (b) displays a gradually increasing trend towards an equilibrium displacement for the 5 mm device at 300 V DC, whereas Figure 35 (b) shows an immediate spike upon powering of the 7 mm device under the same conditions before it tapers off to a seemingly less-actuated equilibrium state. It is believed that the observed discrepancy stems from the difficulty in locating the device center. Referencing Figure 26 again, the 5 mm device was most likely directed at the diaphragm in the same fashion as either the red or blue lines. The 7 mm device results of Figure 35 (b) can then be explained by hitting the device at the same location as the yellow line of Figure 26. For convenience, Figure 38 includes all 3 previously mentioned figures. Under these assumptions, it can be stated that the diaphragms take multiple seconds to realize their full actuation potential, which is far beyond the nanoseconds of delay predicted by capacitive charging and milliseconds predicted for mechanical response to the parallel plate capacitance. 71

85 Figure 38: DC testing results plotted and shown with the figure demonstrating laser redirection based on point of incidence on a deflected diaphragm. 5.9 Acoustic Response Testing Acoustic response testing of the actuators was performed using a Vernier microphone connected to the computer using a LabQuest Mini interface and Logger Lite software. Baseline testing was performed using the Vernier microphone to gather data from a piezoelectric actuator with low voltage, 2000 Hz signals generated by a Keithley 2400 SourceMeter. This test helped establish the acoustic threshold at which it could register variations in sound pressure level (SPL). Based on the calculated acoustic output of the diaphragms, a very quiet response should have been audible at a 1 inch distance from the device surface. The microphone was fixtured at this distance from the device while a range of frequencies around the calculated resonant frequency were applied using the MEMS driver in hopes of triggering the harmonic frequency of the 5 mm diaphragm. In the microfabrication lab there is a great deal of ambient noise from 72

86 the machinery in the room, so the microphone was not capable of picking up any change in actuation response. A fixture was then used to hold the microphone 1 inch from the DUT s surface using convoluted foam to provide acoustic insulation. The inside of this acoustically insulating fixture can be seen in Figure 39, which shows the Vernier microphone tip protruding towards the end of the foam that is placed on the testing surface. The full acoustic testing setup including the foam fixture, microphone, and DUT can be seen in Figure 40. Figure 39: The inside of the acoustic foam fixture with the Vernier microphone inserted. 73

87 Figure 40: Acoustic testing setup including the DUT connected to the MEMS driver and the acoustic foam fixture lifted from where it sits over the DUT. Figure 41 plots the offset pressure seen in the acoustic foam fixture without the device being run. This gives a sense of the ambient SPL noise picked up by the Vernier microphone, which sampled at 10 khz. Testing was then performed using the piezoelectric actuating disc at a variety of voltages at 2 khz to observe the ability of the Vernier microphone to capture fluctuations in SPL. The results of this test can be seen in Figure 42. Note the LoggerPro program output a baseline SPL of 25, and the data plotted is the offset from said SPL. 74

88 Offset Pressure Offset Pressure Time (s) Figure 41: Plot of ambient noise in the acoustic foam fixture Time (s) Figure 42: Offset pressure generated by PZT disc operating at 1 VPP and 2 khz with a 10 khz sampling rate. Figure 42 demonstrates a strong signal from the actuating device, with noticeable oscillation of the minima and maxima from the noise of the system. With knowledge of what an audible acoustic response looks like in terms of SPL response, device testing 75

89 Offset Pressure was performed using 5 and 7 mm devices. The 5 mm devices did not create an audible sound at any frequency tested, but the 7 mm devices were capable of producing an audible noise when operating between approximately 800 and 3000 Hz and the observer was within approximately 6 inches of the device. This gave hope of registering an acoustic output using the microphone, although such results were not attained. Tests were performed on 7 mm devices 1 and 2 at 300 V and frequencies of 2 and 5 Hz as well as a sweep from Hz. Figure 43 shows the data from a test of 7 mm device 2 actuating at 2000 Hz with a 300 V potential applied using the MEMS driver. The amplitude of the SPL offset oscillations during diaphragm testing is equivalent to the noise in Figure 41, suggesting that the pressure waves from the diaphragm were not detected by the microphone Time (s) Figure 43: Plot of 7 mm device 2 actuating at 2000 Hz with 300 V applied. 76

90 5.10 Conclusions While actuation and detection of said actuation was achieved using all 3 diaphragm sizes and this optical test bed, there remains much room for improvement in the test setup. Reliability and repeatability are critical factors in an electrostatic actuator, whether the end goal is for hearing aids or microfluidics. One major repeatability issue lies in the failure to locate the laser on the exact center of the diaphragm. Real time tracking of the laser as it scans across the DUT surface while simultaneously seeking a local, non-zero plateau in the change of voltage during deflection is practically impossible. The ability to achieve this feat would vary greatly on a run-by-run and appraiser-by-appraiser basis, meaning the issue lies in the testing setup itself. The fact that the change oscillation amplitude during AC testing was proven to be indistinguishable from the system noise suggests the devices themselves can actuate with a reasonable degree of reliability. PSD s used in past optical test beds have been known to suffer from the same drift tendencies seen in this testing, so even though the PSD has a high resolution, the reliability issues that stem from its drift tendencies are significant enough to void any analyses performed on hour-long DC tests. This was seen by the large spikes between each collection point in Figures 34 (a) and 35 (a). The helium-neon laser used for the test was likely sufficient for this form of analysis if its beam diameter were condensed to a fraction of its current size. The circular laser beam has a high angle of incidence which means on the PSD and diaphragm surfaces, an elliptic shape is formed. For this reason, it is very likely the antipodal points of the major axis are incident on an angled diaphragm surface and assumption 2 of section 5.4 is inadequate for accurate deflection calculations. 77

91 Overall, 7 mm devices outperformed the smaller ones by far due to the greatly increased electrostatic force generated from the larger area. These were the only devices that successfully achieved both visible and audible actuation at various frequencies. All devices were actuated thousands of times with no sign of damage, so no definitive conclusions can be made on their lifespans. The theoretical deflection of 7 mm devices is only double that of 5 mm devices, but the testing results yielded drastically different deflections between the two sizes. 78

92 SECTION 6. RECOMMENDATIONS FOR FUTURE WORK 6.1 Diaphragms As was established in the optical testing analysis, the 4 mm and 5 mm deflections were statistically identical. Neither of those devices produced audible acoustic output, so in the case of researching electrostatic actuation for a micro-speaker application the devices are inadequate as they are currently fabricated. An analysis of which factors effect diaphragm displacement most was performed by Elizabeth Brooks when she was fabricating the first batch of diaphragms from SOI wafers. The results of this analysis, which was performed by differentiating displacement with respect to each factor independently in the critical design parameter equation below, where d is the deflection distance d 0 2 = ε ε 0 V 2 a4 E h The results of this analysis yielded diaphragm thickness to be the critical design factor of utmost significant to determining potential deflection, followed by side length. 11 In future diaphragm fabrication attempts, creation of a thinner diaphragm is paramount to achieving an acoustic response from a 5 mm device with the other electrostatic actuation limitations present. Silicon is most understood and experimented with in the Cal Poly Microfabrication Lab and aiming for an 8 μm thick by 5 mm side length silicon diaphragm would deflect approximately the same as the 10 μm thick by 7 mm side length diaphragms that saw the most success in this project. Alternately, experimentation of diaphragm actuation for acoustic purposes has been performed in other labs that saw success using graphene with a thickness of a few hundred nanometers

93 6.2 DAQ Amplifiers such as the MEMS driver can have a slew rate that causes measurable losses in the efficiency of high frequencies devices such as a microspeaker. Within the scope of this project, there was no such concern because the response time of the Agilent DAQ was so significantly slower than the driver slew rate. Upgrading the DAQ used for optical testing to one capable of at least 6 khz sampling rate is a requirement for future characterization endeavors. Assuming future characterization of diaphragms will be done using at least 5 mm diaphragms, a minimum 6 khz sampling frequency would provide adequate leeway when determining resonant frequency to avoid aliasing based on theoretical calculations. Three potential routes can be taken when upgrading the data collection device: a different type of DAQ such as a DT9839 USB powered sound and vibration DAQ, a signal analyzer, or a digitizing oscilloscope. Using a digitizing oscilloscope is by far the most cost effective means of achieving data collection rates in the gigahertz range so frequency response would no longer be a concern. 6.3 Test Bed Optical characterization has resulted in very poor reliability and repeatability on the part of the test bed itself. A number of steps can be taken to mitigate these issues, the most important of which being to consistently target the center of the diaphragm with a relatively small diameter laser. The most likely means of achieving this is with a beam condenser that can focus the laser down to the smallest point possible on the diaphragm surface. Beam divergence and wavelength are the primary factors determining the laser s minimum spot size, but for future testing a.5 mm (50 μm) diameter spot size should suffice based on the size of the smallest diaphragm tested and the low deflection angle at its center. This condensed laser point can then be centered with the aid of a 80

94 camera feed that could display a greatly enlarged image of the diaphragm on a computer screen. The fine adjustment stages used to position the DUT in the current system can then be used to their full potential. Vibrational isolation is another critical component of improved characterization capability for an optics based test setup. There is no reason moving forward with the project that the testing equipment needs to remain in the microfabrication lab, so the option of relocating all equipment to a ground-floor room with more vibrational and acoustic isolation. This has the potential to increase system reliability and repeatability to levels that make long term DC reliability testing viable. In a location with significantly less ambient noise than the microfabrication lab, the pressure waves generated by diaphragms have a much better chance of being detected as well. A number of additional components can be added to the test bed in order to utilize vibrometry, which has the capability of directly measuring frequency and displacement of small, high frequency devices. Laser-doppler Vibrometry takes advantage of the principles of optical interferometry by using two coherent helium-neon laser beams with overlapping intensities to determine the difference in path length between beams and allow the Doppler effect to be analyzed. 21 The Doppler effect is based on the frequency shift of a wave coming off a vibrating surface, which is described by the following equation: f D = 2 v/λ 6.2 where v is the object velocity and λ is the emitted (known) wavelength. With overlapping light sources, an interference factor is created which relates to the path length difference between beams. The light intensity equation behind this theory is as follows: 81

95 I tot = I 1 + I I 1 I 2 cos (2 pi r 1 r 2 λ ) 6.3 where I is the intensity of a given light source and r is the path length. In order to use laser-doppler vibrometry, the additional components include 3 beam splitters, a mirror, a Bragg cell (also known as an acoustic-optic modulator), and an optical condensing lens. An example setup of such a system is seen in Figure 44. Figure 44: An example setup that can be used in laser-doppler vibrometry. 21 Such a system is considerably more complex than the current characterization setup, but with it comes a well-established means of characterizing high frequency actuators with vastly greater accuracy. 6.4 MEMS Driver Program The LabView program that controls the MEMS driver can be modified to allow the capability of a voltage sweep test. This would allow for an automated means of covering a large range of frequencies at small voltage intervals to locate the resonant frequency of the device. A simple loop could be implemented in the program to allow voltage to be 82

96 incremented until an amplitude spike is registered by the DAQ or a maximum frequency has been reached. 6.5 Data Filtering The data analysis process was excessively time consuming for this project due to the large quantity of data that frequently had too great of a noise to signal ratio. Steps can be taken to ease this analysis in the future by applying a low pass filter that can eliminate some of the high frequency distortion caused by the noise of the measurement system. This on top of general noise dampening from relocating the test environment could be the factors that improve system resolution capabilities to the level of individual microns. 6.6 Finite Element Modelling In the future, larger devices (e.g. 7 mm) should be modeled and analyzed using a finite element approach assuming they will continue to be fabricated due to their documented acoustic capabilities. FEA of such a device could provide insight as to why its physical response was so different from the 4 and 5 mm devices. Future analyses should use the built-in electrostatic effects analysis features of Abaqus/CAE rather than the physical pressure loading approach taken in this study. By applying a calculated equivalent pressure load on the diaphragm, a small margin of error is introduced from an early stage of the analysis. If a non-physical approach to measuring the electrode gap is taken, additional accuracy could also be implemented into that parameter for all calculations and modelling. An electrostatic analysis in Abaqus could also be performed on a 5 mm device to compare the results to those of this physical loading analysis. This would help validate future work done using the equivalent pressure load to calculate electrostatic effects. 83

97 REFERENCES 1. Gordon E. Moore, Cramming More Components onto Integrated Circuits, Electronics. April 19, 1965: Web. 12 March Halbo, Leif, and Ohlckers, Per. "Micro Structure Technology and Micromachined Devices." Electronics Components, Packaging and Production. Oslo: Strandberg & Nilsen Grafisk A.s, Print. 3. Zhang W-M, Meng G, and Chen D. Stability, Nonlinearity and Reliability of Electrostatically Actuated MEMS Devices. Sensors. 2007; 7(5): C. Liu, Foundations of Mems. Prentice Hall, Stiff Structures, Compliant Mechanisms, and MEMS: A short course offered at IISc, Bangalore, India. Aug.-Sep., G. K. Ananthasuresh 6. Tipler, Paul A. Physics for Scientists and Engineers. New York: W.H. Freeman/Worth Publishers, Print. 22 April Elie LEFEUVRE, Iman Shahosseini, Johan Moulin, Marion Woytasik, Emile Martincic, et al.. Potential of MEMS technologies for manufacturing of high-fidelity microspeakers. Soci et e Francaise d Acoustique. Acoustics 2012, Apr 2012, Nantes, France. <hal > 8. Fletcher, Harvey, and W. A. Munson. "Loudness, Its Definition, Measurement and Calculation. The Journal of the Acoustical Society of America 12.4 (1933): Wiley Online Library. Web. 5 April "Sound in Air." Help Wiki. The Evergreen State College, 22 Oct Web. 01 Apr E. Cate, M.S. thesis, Design, Implementation, and Test of a Micro Force Displacement System, California Polytechnic State University- San Luis Obispo,

98 11. E. Brooks. M.S. Thesis, The Design and Fabrication of an Electrostatically Actuated Diaphragm with a Silicon-on-Insulator Wafer. California Polytechnic State University- San Luis Obispo Je, San-Soo, Fernando Rivas, Rodolfo E. Diaz, Juik Kwon, and Joenghwan Kim. "A Compact and Low-Cost MEMS Loudspeaker for Digital Hearing Aids." IEEE Explore, Oct Web. 13. Chapter 4 Engineering mechanics for microsystems design. (2008). Informally published manuscript, Retrieved from 4.pdf. 14. T. Hsu, MEMS & Microsystems Design and Manufacture. McGraw-Hill. New York, 2002: J. Yoon, M.S. thesis, Aluminum/Aluminum Oxide (Yoon, 2010) Structured Microplasma Devices: Paschen s Law and Applications. University of Illinois at Urbana-Champaign, B. Huigens. M.S. Thesis, Mechanical Reliability of Micro Electrostatic Actuation for MEMS Applications. California Polytechnic State University- San Luis Obispo Sputtering Vacuum Deposition Process [Print Graphic]. Retrieved from Hye Jin Kim, Kunmo Koo, Sung Q Lee, Kang-Ho Park, and Jongdae Kim, "High Performance Piezoelectric Microspeakers and Thin Speaker Array System," ETRI Journal, vol. 31, no. 6, Dec. 2009: Nyquist Theorem - Sampling Rate Versus Bandwidth." National Instruments. N.p., 6 Sept Web. 26 Apr Sloop, Rick. "Understand Gage R&R." Qualitymag.com. N.p., 1 Sept Web. 12 May

99 21. "Basic Principles of Vibrometry." Polytec GmbH Waldbronn, Web. 27 Mar Zhou, Qin, and A. Zettl. "Electrostatic Graphene Loudspeaker." University of California at Berkeley. Web. 8 June Retrieved from 86

100 APPENDICES Appendix I. Theoretical Electrostatics Calculations Diaphragm Side Length (mm) Electrostatic actuation calculations for each diaphragm size Electrode gap (m) Force with 300 V applied Stress (Pa) Displacement (m) N 4.01E6 1.69E N 6.26E6 4.12E N 12.27E6 8.08E-6 Theoretical electrostatic force applied by the stated voltage on a 5 mm diaphragm Applied Voltage (V) Electrode Gap Theoretical deflection in meters due to the electrostatic force on a 5 mm diaphragm Applied Voltage (V) Electrode Gap (m) E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E-06 87

101 Appendix II. Finite Element Modelling Inner Edges Outer Edges Quarter-model utilizing symmetry of boundary and loading conditions High stress node at middle of silicon edge selected for stress based mesh convergence study 88

102 Stress (Pa) Max displacement node at center of diaphragm selected for mesh convergence check 4.50E E E E E E E E E E Degrees of Freedom 5mm x 5mm stress based mesh convergence study plot 89

103 Dynamic 2.5 mm x 2.5 mm quarter-model stress results at frequency 4456 Hz 90

High-speed wavefront control using MEMS micromirrors T. G. Bifano and J. B. Stewart, Boston University [ ] Introduction

High-speed wavefront control using MEMS micromirrors T. G. Bifano and J. B. Stewart, Boston University [ ] Introduction High-speed wavefront control using MEMS micromirrors T. G. Bifano and J. B. Stewart, Boston University [5895-27] Introduction Various deformable mirrors for high-speed wavefront control have been demonstrated

More information

Part 2: Second order systems: cantilever response

Part 2: Second order systems: cantilever response - cantilever response slide 1 Part 2: Second order systems: cantilever response Goals: Understand the behavior and how to characterize second order measurement systems Learn how to operate: function generator,

More information

describe sound as the transmission of energy via longitudinal pressure waves;

describe sound as the transmission of energy via longitudinal pressure waves; 1 Sound-Detailed Study Study Design 2009 2012 Unit 4 Detailed Study: Sound describe sound as the transmission of energy via longitudinal pressure waves; analyse sound using wavelength, frequency and speed

More information

PROBLEM SET #7. EEC247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2015 C. Nguyen. Issued: Monday, April 27, 2015

PROBLEM SET #7. EEC247B / ME C218 INTRODUCTION TO MEMS DESIGN SPRING 2015 C. Nguyen. Issued: Monday, April 27, 2015 Issued: Monday, April 27, 2015 PROBLEM SET #7 Due (at 9 a.m.): Friday, May 8, 2015, in the EE C247B HW box near 125 Cory. Gyroscopes are inertial sensors that measure rotation rate, which is an extremely

More information

ENHANCEMENT OF THE TRANSMISSION LOSS OF DOUBLE PANELS BY MEANS OF ACTIVELY CONTROLLING THE CAVITY SOUND FIELD

ENHANCEMENT OF THE TRANSMISSION LOSS OF DOUBLE PANELS BY MEANS OF ACTIVELY CONTROLLING THE CAVITY SOUND FIELD ENHANCEMENT OF THE TRANSMISSION LOSS OF DOUBLE PANELS BY MEANS OF ACTIVELY CONTROLLING THE CAVITY SOUND FIELD André Jakob, Michael Möser Technische Universität Berlin, Institut für Technische Akustik,

More information

EWGAE 2010 Vienna, 8th to 10th September

EWGAE 2010 Vienna, 8th to 10th September EWGAE 2010 Vienna, 8th to 10th September Frequencies and Amplitudes of AE Signals in a Plate as a Function of Source Rise Time M. A. HAMSTAD University of Denver, Department of Mechanical and Materials

More information

Piezoelectric Sensors and Actuators

Piezoelectric Sensors and Actuators Piezoelectric Sensors and Actuators Outline Piezoelectricity Origin Polarization and depolarization Mathematical expression of piezoelectricity Piezoelectric coefficient matrix Cantilever piezoelectric

More information

Response spectrum Time history Power Spectral Density, PSD

Response spectrum Time history Power Spectral Density, PSD A description is given of one way to implement an earthquake test where the test severities are specified by time histories. The test is done by using a biaxial computer aided servohydraulic test rig.

More information

High Power RF MEMS Switch Technology

High Power RF MEMS Switch Technology High Power RF MEMS Switch Technology Invited Talk at 2005 SBMO/IEEE MTT-S International Conference on Microwave and Optoelectronics Conference Dr Jia-Sheng Hong Heriot-Watt University Edinburgh U.K. 1

More information

BMC s heritage deformable mirror technology that uses hysteresis free electrostatic

BMC s heritage deformable mirror technology that uses hysteresis free electrostatic Optical Modulator Technical Whitepaper MEMS Optical Modulator Technology Overview The BMC MEMS Optical Modulator, shown in Figure 1, was designed for use in free space optical communication systems. The

More information

Micro-nanosystems for electrical metrology and precision instrumentation

Micro-nanosystems for electrical metrology and precision instrumentation Micro-nanosystems for electrical metrology and precision instrumentation A. Bounouh 1, F. Blard 1,2, H. Camon 2, D. Bélières 1, F. Ziadé 1 1 LNE 29 avenue Roger Hennequin, 78197 Trappes, France, alexandre.bounouh@lne.fr

More information

CHAPTER 6 INTRODUCTION TO SYSTEM IDENTIFICATION

CHAPTER 6 INTRODUCTION TO SYSTEM IDENTIFICATION CHAPTER 6 INTRODUCTION TO SYSTEM IDENTIFICATION Broadly speaking, system identification is the art and science of using measurements obtained from a system to characterize the system. The characterization

More information

AN5E Application Note

AN5E Application Note Metra utilizes for factory calibration a modern PC based calibration system. The calibration procedure is based on a transfer standard which is regularly sent to Physikalisch-Technische Bundesanstalt (PTB)

More information

Development of a Package for a Triaxial High-G Accelerometer Optimized for High Signal Fidelity

Development of a Package for a Triaxial High-G Accelerometer Optimized for High Signal Fidelity Development of a Package for a Triaxial High-G Accelerometer Optimized for High Signal Fidelity R. Langkemper* 1, R. Külls 1, J. Wilde 2, S. Schopferer 1 and S. Nau 1 1 Fraunhofer Institute for High-Speed

More information

A study of Vibration Analysis for Gearbox Casing Using Finite Element Analysis

A study of Vibration Analysis for Gearbox Casing Using Finite Element Analysis A study of Vibration Analysis for Gearbox Casing Using Finite Element Analysis M. Sofian D. Hazry K. Saifullah M. Tasyrif K.Salleh I.Ishak Autonomous System and Machine Vision Laboratory, School of Mechatronic,

More information

5. Transducers Definition and General Concept of Transducer Classification of Transducers

5. Transducers Definition and General Concept of Transducer Classification of Transducers 5.1. Definition and General Concept of Definition The transducer is a device which converts one form of energy into another form. Examples: Mechanical transducer and Electrical transducer Electrical A

More information

Chapter 30: Principles of Active Vibration Control: Piezoelectric Accelerometers

Chapter 30: Principles of Active Vibration Control: Piezoelectric Accelerometers Chapter 30: Principles of Active Vibration Control: Piezoelectric Accelerometers Introduction: Active vibration control is defined as a technique in which the vibration of a structure is reduced or controlled

More information

Supplementary Information

Supplementary Information Supplementary Information Supplementary Figure 1. Modal simulation and frequency response of a high- frequency (75- khz) MEMS. a, Modal frequency of the device was simulated using Coventorware and shows

More information

FREQUENCY RESPONSE AND LATENCY OF MEMS MICROPHONES: THEORY AND PRACTICE

FREQUENCY RESPONSE AND LATENCY OF MEMS MICROPHONES: THEORY AND PRACTICE APPLICATION NOTE AN22 FREQUENCY RESPONSE AND LATENCY OF MEMS MICROPHONES: THEORY AND PRACTICE This application note covers engineering details behind the latency of MEMS microphones. Major components of

More information

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air Resonance Tube Equipment Capstone, complete resonance tube (tube, piston assembly, speaker stand, piston stand, mike with adaptors, channel), voltage sensor, 1.5 m leads (2), (room) thermometer, flat rubber

More information

Design and simulation of a membranes-based acoustic sensors array for cochlear implant applications

Design and simulation of a membranes-based acoustic sensors array for cochlear implant applications Design and simulation of a membranes-based acoustic sensors array for cochlear implant applications Quiroz G.*, Báez H., Mendoza S., Alemán M., Villa L. National Polytechnic Institute Computing Research

More information

Modal Analysis of Microcantilever using Vibration Speaker

Modal Analysis of Microcantilever using Vibration Speaker Modal Analysis of Microcantilever using Vibration Speaker M SATTHIYARAJU* 1, T RAMESH 2 1 Research Scholar, 2 Assistant Professor Department of Mechanical Engineering, National Institute of Technology,

More information

1.6 Beam Wander vs. Image Jitter

1.6 Beam Wander vs. Image Jitter 8 Chapter 1 1.6 Beam Wander vs. Image Jitter It is common at this point to look at beam wander and image jitter and ask what differentiates them. Consider a cooperative optical communication system that

More information

Resonance Tube Lab 9

Resonance Tube Lab 9 HB 03-30-01 Resonance Tube Lab 9 1 Resonance Tube Lab 9 Equipment SWS, complete resonance tube (tube, piston assembly, speaker stand, piston stand, mike with adaptors, channel), voltage sensor, 1.5 m leads

More information

VLSI Layout Based Design Optimization of a Piezoresistive MEMS Pressure Sensors Using COMSOL

VLSI Layout Based Design Optimization of a Piezoresistive MEMS Pressure Sensors Using COMSOL VLSI Layout Based Design Optimization of a Piezoresistive MEMS Pressure Sensors Using COMSOL N Kattabooman 1,, Sarath S 1, Rama Komaragiri *1, Department of ECE, NIT Calicut, Calicut, Kerala, India 1 Indian

More information

A large-area wireless power transmission sheet using printed organic. transistors and plastic MEMS switches

A large-area wireless power transmission sheet using printed organic. transistors and plastic MEMS switches Supplementary Information A large-area wireless power transmission sheet using printed organic transistors and plastic MEMS switches Tsuyoshi Sekitani 1, Makoto Takamiya 2, Yoshiaki Noguchi 1, Shintaro

More information

Introduction to Measurement Systems

Introduction to Measurement Systems MFE 3004 Mechatronics I Measurement Systems Dr Conrad Pace Page 4.1 Introduction to Measurement Systems Role of Measurement Systems Detection receive an external stimulus (ex. Displacement) Selection measurement

More information

Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry

Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry 1 Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry 2 Back to our solutions: The main problem: How to get nm

More information

Analysis on Acoustic Attenuation by Periodic Array Structure EH KWEE DOE 1, WIN PA PA MYO 2

Analysis on Acoustic Attenuation by Periodic Array Structure EH KWEE DOE 1, WIN PA PA MYO 2 www.semargroup.org, www.ijsetr.com ISSN 2319-8885 Vol.03,Issue.24 September-2014, Pages:4885-4889 Analysis on Acoustic Attenuation by Periodic Array Structure EH KWEE DOE 1, WIN PA PA MYO 2 1 Dept of Mechanical

More information

2007-Novel structures of a MEMS-based pressure sensor

2007-Novel structures of a MEMS-based pressure sensor C-(No.16 font) put by office 2007-Novel structures of a MEMS-based pressure sensor Chang-Sin Park(*1), Young-Soo Choi(*1), Dong-Weon Lee (*2) and Bo-Seon Kang(*2) (1*) Department of Mechanical Engineering,

More information

Pressure Response of a Pneumatic System

Pressure Response of a Pneumatic System Pressure Response of a Pneumatic System by Richard A., PhD rick.beier@okstate.edu Mechanical Engineering Technology Department Oklahoma State University, Stillwater Abstract This paper describes an instructive

More information

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications Part I: RF Applications Introductions and Motivations What are RF MEMS? Example Devices RFIC RFIC consists of Active components

More information

PIEZOELECTRIC TRANSFORMER FOR INTEGRATED MOSFET AND IGBT GATE DRIVER

PIEZOELECTRIC TRANSFORMER FOR INTEGRATED MOSFET AND IGBT GATE DRIVER 1 PIEZOELECTRIC TRANSFORMER FOR INTEGRATED MOSFET AND IGBT GATE DRIVER Prasanna kumar N. & Dileep sagar N. prasukumar@gmail.com & dileepsagar.n@gmail.com RGMCET, NANDYAL CONTENTS I. ABSTRACT -03- II. INTRODUCTION

More information

Presented at the 109th Convention 2000 September Los Angeles, California, USA

Presented at the 109th Convention 2000 September Los Angeles, California, USA Development of a Piezo-Electric Super Tweeter Suitable for DVD-Audio 5 Mitsukazu Kuze and Kazue Satoh Multimedia Development Center Matsushita Electric Industrial Co., Ltd. Kadoma-city, Osaka 57 l-8, Japan

More information

Mechanical characterization of MEMS bi-stable buckled diaphragms.

Mechanical characterization of MEMS bi-stable buckled diaphragms. University of Louisville ThinkIR: The University of Louisville's Institutional Repository Electronic Theses and Dissertations 5-2013 Mechanical characterization of MEMS bi-stable buckled diaphragms. Isaac

More information

Characterization of Silicon-based Ultrasonic Nozzles

Characterization of Silicon-based Ultrasonic Nozzles Tamkang Journal of Science and Engineering, Vol. 7, No. 2, pp. 123 127 (24) 123 Characterization of licon-based Ultrasonic Nozzles Y. L. Song 1,2 *, S. C. Tsai 1,3, Y. F. Chou 4, W. J. Chen 1, T. K. Tseng

More information

Basic methods in imaging of micro and nano structures with atomic force microscopy (AFM)

Basic methods in imaging of micro and nano structures with atomic force microscopy (AFM) Basic methods in imaging of micro and nano P2538000 AFM Theory The basic principle of AFM is very simple. The AFM detects the force interaction between a sample and a very tiny tip (

More information

EQUIVALENT THROAT TECHNOLOGY

EQUIVALENT THROAT TECHNOLOGY EQUIVALENT THROAT TECHNOLOGY Modern audio frequency reproduction systems use transducers to convert electrical energy to acoustical energy. Systems used for the reinforcement of speech and music are referred

More information

3D Distortion Measurement (DIS)

3D Distortion Measurement (DIS) 3D Distortion Measurement (DIS) Module of the R&D SYSTEM S4 FEATURES Voltage and frequency sweep Steady-state measurement Single-tone or two-tone excitation signal DC-component, magnitude and phase of

More information

Application Note: Precision Displacement Test Stand Rev A

Application Note: Precision Displacement Test Stand Rev A Radiant Technologies, Inc. 2835D Pan American Freeway NE Albuquerque, NM 87107 Tel: 505-842-8007 Fax: 505-842-0366 e-mail: radiant@ferrodevices.com www.ferrodevices.com Application Note: Precision Displacement

More information

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans. Electronic Measurements & Instrumentation

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans.   Electronic Measurements & Instrumentation UNIT 2 Q.1) Describe the functioning of standard signal generator Ans. STANDARD SIGNAL GENERATOR A standard signal generator produces known and controllable voltages. It is used as power source for the

More information

Experimental investigation of crack in aluminum cantilever beam using vibration monitoring technique

Experimental investigation of crack in aluminum cantilever beam using vibration monitoring technique International Journal of Computational Engineering Research Vol, 04 Issue, 4 Experimental investigation of crack in aluminum cantilever beam using vibration monitoring technique 1, Akhilesh Kumar, & 2,

More information

A HIGH SENSITIVITY POLYSILICON DIAPHRAGM CONDENSER MICROPHONE

A HIGH SENSITIVITY POLYSILICON DIAPHRAGM CONDENSER MICROPHONE To be presented at the 1998 MEMS Conference, Heidelberg, Germany, Jan. 25-29 1998 1 A HIGH SENSITIVITY POLYSILICON DIAPHRAGM CONDENSER MICROPHONE P.-C. Hsu, C. H. Mastrangelo, and K. D. Wise Center for

More information

MICRO YAW RATE SENSORS

MICRO YAW RATE SENSORS 1 MICRO YAW RATE SENSORS FIELD OF THE INVENTION This invention relates to micro yaw rate sensors suitable for measuring yaw rate around its sensing axis. More particularly, to micro yaw rate sensors fabricated

More information

SmartSenseCom Introduces Next Generation Seismic Sensor Systems

SmartSenseCom Introduces Next Generation Seismic Sensor Systems SmartSenseCom Introduces Next Generation Seismic Sensor Systems Summary: SmartSenseCom, Inc. (SSC) has introduced the next generation in seismic sensing technology. SSC s systems use a unique optical sensing

More information

Generation of Sub-nanosecond Pulses

Generation of Sub-nanosecond Pulses Chapter - 6 Generation of Sub-nanosecond Pulses 6.1 Introduction principle of peaking circuit In certain applications like high power microwaves (HPM), pulsed laser drivers, etc., very fast rise times

More information

being developed. Most up and coming drugs are extremely expensive and limited in

being developed. Most up and coming drugs are extremely expensive and limited in Introduction In the pharmaceutical industry, it is important to know fluid properties of the drug being developed. Most up and coming drugs are extremely expensive and limited in quantity. A device that

More information

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air Resonance Tube Equipment Capstone, complete resonance tube (tube, piston assembly, speaker stand, piston stand, mike with adapters, channel), voltage sensor, 1.5 m leads (2), (room) thermometer, flat rubber

More information

Periodic Error Correction in Heterodyne Interferometry

Periodic Error Correction in Heterodyne Interferometry Periodic Error Correction in Heterodyne Interferometry Tony L. Schmitz, Vasishta Ganguly, Janet Yun, and Russell Loughridge Abstract This paper describes periodic error in differentialpath interferometry

More information

(i) Sine sweep (ii) Sine beat (iii) Time history (iv) Continuous sine

(i) Sine sweep (ii) Sine beat (iii) Time history (iv) Continuous sine A description is given of one way to implement an earthquake test where the test severities are specified by the sine-beat method. The test is done by using a biaxial computer aided servohydraulic test

More information

MEMS Optical Scanner "ECO SCAN" Application Notes. Ver.0

MEMS Optical Scanner ECO SCAN Application Notes. Ver.0 MEMS Optical Scanner "ECO SCAN" Application Notes Ver.0 Micro Electro Mechanical Systems Promotion Dept., Visionary Business Center The Nippon Signal Co., Ltd. 1 Preface This document summarizes precautions

More information

PHYS102 Previous Exam Problems. Sound Waves. If the speed of sound in air is not given in the problem, take it as 343 m/s.

PHYS102 Previous Exam Problems. Sound Waves. If the speed of sound in air is not given in the problem, take it as 343 m/s. PHYS102 Previous Exam Problems CHAPTER 17 Sound Waves Sound waves Interference of sound waves Intensity & level Resonance in tubes Doppler effect If the speed of sound in air is not given in the problem,

More information

14.2 Photodiodes 411

14.2 Photodiodes 411 14.2 Photodiodes 411 Maximum reverse voltage is specified for Ge and Si photodiodes and photoconductive cells. Exceeding this voltage can cause the breakdown and severe deterioration of the sensor s performance.

More information

Section 7 - Measurement of Transient Pressure Pulses

Section 7 - Measurement of Transient Pressure Pulses Section 7 - Measurement of Transient Pressure Pulses Special problems are encountered in transient pressure pulse measurement, which place stringent requirements on the measuring system. Some of these

More information

Deformable Membrane Mirror for Wavefront Correction

Deformable Membrane Mirror for Wavefront Correction Defence Science Journal, Vol. 59, No. 6, November 2009, pp. 590-594 Ó 2009, DESIDOC SHORT COMMUNICATION Deformable Membrane Mirror for Wavefront Correction Amita Gupta, Shailesh Kumar, Ranvir Singh, Monika

More information

(i) Determine the admittance parameters of the network of Fig 1 (f) and draw its - equivalent circuit.

(i) Determine the admittance parameters of the network of Fig 1 (f) and draw its - equivalent circuit. I.E.S-(Conv.)-1995 ELECTRONICS AND TELECOMMUNICATION ENGINEERING PAPER - I Some useful data: Electron charge: 1.6 10 19 Coulomb Free space permeability: 4 10 7 H/m Free space permittivity: 8.85 pf/m Velocity

More information

Efficient Electromagnetic Analysis of Spiral Inductor Patterned Ground Shields

Efficient Electromagnetic Analysis of Spiral Inductor Patterned Ground Shields Efficient Electromagnetic Analysis of Spiral Inductor Patterned Ground Shields James C. Rautio, James D. Merrill, and Michael J. Kobasa Sonnet Software, North Syracuse, NY, 13212, USA Abstract Patterned

More information

Optical MEMS pressure sensor based on a mesa-diaphragm structure

Optical MEMS pressure sensor based on a mesa-diaphragm structure Optical MEMS pressure sensor based on a mesa-diaphragm structure Yixian Ge, Ming WanJ *, and Haitao Yan Jiangsu Key Lab on Opto-Electronic Technology, School of Physical Science and Technology, Nanjing

More information

1241. Efficiency improvement of energy harvester at higher frequencies

1241. Efficiency improvement of energy harvester at higher frequencies 24. Efficiency improvement of energy harvester at higher frequencies Giedrius Janusas, Ieva Milasauskaite 2, Vytautas Ostasevicius 3, Rolanas Dauksevicius 4 Kaunas University of Technology, Kaunas, Lithuania

More information

A Numerical study on proper mode and frequency selection for riveted lap joints inspection using Lamb waves.

A Numerical study on proper mode and frequency selection for riveted lap joints inspection using Lamb waves. More Info at Open Access Database www.ndt.net/?id=18676 A Numerical study on proper mode and frequency selection for riveted lap joints inspection using Lamb waves. Mohammad. (. SOORGEE Nondestructive

More information

430. The Research System for Vibration Analysis in Domestic Installation Pipes

430. The Research System for Vibration Analysis in Domestic Installation Pipes 430. The Research System for Vibration Analysis in Domestic Installation Pipes R. Ramanauskas, D. Gailius, V. Augutis Kaunas University of Technology, Studentu str. 50, LT-51424, Kaunas, Lithuania e-mail:

More information

MEMS in ECE at CMU. Gary K. Fedder

MEMS in ECE at CMU. Gary K. Fedder MEMS in ECE at CMU Gary K. Fedder Department of Electrical and Computer Engineering and The Robotics Institute Carnegie Mellon University Pittsburgh, PA 15213-3890 fedder@ece.cmu.edu http://www.ece.cmu.edu/~mems

More information

ACTIVE CONTROL OF AUTOMOBILE CABIN NOISE WITH CONVENTIONAL AND ADVANCED SPEAKERS. by Jerome Couche

ACTIVE CONTROL OF AUTOMOBILE CABIN NOISE WITH CONVENTIONAL AND ADVANCED SPEAKERS. by Jerome Couche ACTIVE CONTROL OF AUTOMOBILE CABIN NOISE WITH CONVENTIONAL AND ADVANCED SPEAKERS by Jerome Couche Thesis submitted to the Faculty of the Virginia Polytechnic Institute and State University in partial fulfillment

More information

Development of Random Vibration Profiles for Test Deployers to Simulate the Dynamic Environment in the Poly-Picosatellite Orbital Deployer

Development of Random Vibration Profiles for Test Deployers to Simulate the Dynamic Environment in the Poly-Picosatellite Orbital Deployer Development of Random Vibration Profiles for Test Deployers to Simulate the Dynamic Environment in the Poly-Picosatellite Orbital Deployer Steve Furger California Polytechnic State University, San Luis

More information

A detailed experimental modal analysis of a clamped circular plate

A detailed experimental modal analysis of a clamped circular plate A detailed experimental modal analysis of a clamped circular plate David MATTHEWS 1 ; Hongmei SUN 2 ; Kyle SALTMARSH 2 ; Dan WILKES 3 ; Andrew MUNYARD 1 and Jie PAN 2 1 Defence Science and Technology Organisation,

More information

A White Paper on Danley Sound Labs Tapped Horn and Synergy Horn Technologies

A White Paper on Danley Sound Labs Tapped Horn and Synergy Horn Technologies Tapped Horn (patent pending) Horns have been used for decades in sound reinforcement to increase the loading on the loudspeaker driver. This is done to increase the power transfer from the driver to the

More information

CHAPTER 2 POLARIZATION SPLITTER- ROTATOR BASED ON A DOUBLE- ETCHED DIRECTIONAL COUPLER

CHAPTER 2 POLARIZATION SPLITTER- ROTATOR BASED ON A DOUBLE- ETCHED DIRECTIONAL COUPLER CHAPTER 2 POLARIZATION SPLITTER- ROTATOR BASED ON A DOUBLE- ETCHED DIRECTIONAL COUPLER As we discussed in chapter 1, silicon photonics has received much attention in the last decade. The main reason is

More information

UNIVERSITY OF UTAH ELECTRICAL ENGINEERING DEPARTMENT LABORATORY PROJECT NO. 3 DESIGN OF A MICROMOTOR DRIVER CIRCUIT

UNIVERSITY OF UTAH ELECTRICAL ENGINEERING DEPARTMENT LABORATORY PROJECT NO. 3 DESIGN OF A MICROMOTOR DRIVER CIRCUIT UNIVERSITY OF UTAH ELECTRICAL ENGINEERING DEPARTMENT EE 1000 LABORATORY PROJECT NO. 3 DESIGN OF A MICROMOTOR DRIVER CIRCUIT 1. INTRODUCTION The following quote from the IEEE Spectrum (July, 1990, p. 29)

More information

09-2 EE 4770 Lecture Transparency. Formatted 12:49, 19 February 1998 from lsli

09-2 EE 4770 Lecture Transparency. Formatted 12:49, 19 February 1998 from lsli 09-1 09-1 Displacement and Proximity Displacement transducers measure the location of an object. Proximity transducers determine when an object is near. Criteria Used in Selection of Transducer How much

More information

Quantitative Crack Depth Study in Homogeneous Plates Using Simulated Lamb Waves.

Quantitative Crack Depth Study in Homogeneous Plates Using Simulated Lamb Waves. More Info at Open Access Database www.ndt.net/?id=18675 Quantitative Crack Depth Study in Homogeneous Plates Using Simulated Lamb Waves. Mohammad. (. SOORGEE, Aghil. YOUSEF)-KOMA Nondestructive Testing

More information

Speech, Hearing and Language: work in progress. Volume 12

Speech, Hearing and Language: work in progress. Volume 12 Speech, Hearing and Language: work in progress Volume 12 2 Construction of a rotary vibrator and its application in human tactile communication Abbas HAYDARI and Stuart ROSEN Department of Phonetics and

More information

RESEARCH PAPERS FACULTY OF MATERIALS SCIENCE AND TECHNOLOGY IN TRNAVA, SLOVAK UNIVERSITY OF TECHNOLOGY IN BRATISLAVA, 2016 Volume 24, Number 39

RESEARCH PAPERS FACULTY OF MATERIALS SCIENCE AND TECHNOLOGY IN TRNAVA, SLOVAK UNIVERSITY OF TECHNOLOGY IN BRATISLAVA, 2016 Volume 24, Number 39 RESEARCH PAPERS FACULTY OF MATERIALS SCIENCE AND TECHNOLOGY IN TRNAVA SLOVAK UNIVERSITY OF TECHNOLOGY IN BRATISLAVA 2016 Volume 24, Number 39 APPLICATION OF NUMERICAL SIMULATION FOR THE ANALYSIS OF THE

More information

Extreme Sensitivity in Photoacoustics by Using Optical Cantilever-type Microphone

Extreme Sensitivity in Photoacoustics by Using Optical Cantilever-type Microphone Extreme Sensitivity in Photoacoustics by Using Optical Cantilever-type Microphone Jyrki Kauppinen, Vesa Koskinen, Minna Huuskonen Department of Physics, University of Turku, FIN-20014 TURKU, Finland, e-mail:

More information

ME 434 MEMS Tuning Fork Gyroscope Amanda Bristow Stephen Nary Travis Barton 12/9/10

ME 434 MEMS Tuning Fork Gyroscope Amanda Bristow Stephen Nary Travis Barton 12/9/10 ME 434 MEMS Tuning Fork Gyroscope Amanda Bristow Stephen Nary Travis Barton 12/9/10 1 Abstract MEMS based gyroscopes have gained in popularity for use as rotation rate sensors in commercial products like

More information

A Review of MEMS Based Piezoelectric Energy Harvester for Low Frequency Applications

A Review of MEMS Based Piezoelectric Energy Harvester for Low Frequency Applications Available Online at www.ijcsmc.com International Journal of Computer Science and Mobile Computing A Monthly Journal of Computer Science and Information Technology IJCSMC, Vol. 3, Issue. 9, September 2014,

More information

Resonant MEMS Acoustic Switch Package with Integral Tuning Helmholtz Cavity

Resonant MEMS Acoustic Switch Package with Integral Tuning Helmholtz Cavity Resonant MEMS Acoustic Switch Package with Integral Tuning Helmholtz Cavity J. Bernstein, M. Bancu, D. Gauthier, M. Hansberry, J. LeBlanc, O. Rappoli, M. Tomaino-Iannucci, M. Weinberg May 1, 2018 Outline

More information

A Tutorial on Acoustical Transducers: Microphones and Loudspeakers

A Tutorial on Acoustical Transducers: Microphones and Loudspeakers A Tutorial on Acoustical Transducers: Microphones and Loudspeakers Robert C. Maher Montana State University EELE 217 Science of Sound Spring 2012 Test Sound Outline Introduction: What is sound? Microphones

More information

SILICON BASED CAPACITIVE SENSORS FOR VIBRATION CONTROL

SILICON BASED CAPACITIVE SENSORS FOR VIBRATION CONTROL SILICON BASED CAPACITIVE SENSORS FOR VIBRATION CONTROL Shailesh Kumar, A.K Meena, Monika Chaudhary & Amita Gupta* Solid State Physics Laboratory, Timarpur, Delhi-110054, India *Email: amita_gupta/sspl@ssplnet.org

More information

Acoustic-Laser Vibrometry for Standoff Detection of Defects in Materials

Acoustic-Laser Vibrometry for Standoff Detection of Defects in Materials 11th European Conference on Non-Destructive Testing (ECNDT 214), October 6-1, 214, Prague, Czech Republic Acoustic-Laser Vibrometry for Standoff Detection of Defects in Materials Oral BUYUKOZTURK 1, Justin

More information

Knowledge Integration Module 2 Fall 2016

Knowledge Integration Module 2 Fall 2016 Knowledge Integration Module 2 Fall 2016 1 Basic Information: The knowledge integration module 2 or KI-2 is a vehicle to help you better grasp the commonality and correlations between concepts covered

More information

Kit for building your own THz Time-Domain Spectrometer

Kit for building your own THz Time-Domain Spectrometer Kit for building your own THz Time-Domain Spectrometer 16/06/2016 1 Table of contents 0. Parts for the THz Kit... 3 1. Delay line... 4 2. Pulse generator and lock-in detector... 5 3. THz antennas... 6

More information

In this lecture we will begin a new topic namely the Metal-Oxide-Semiconductor Field Effect Transistor.

In this lecture we will begin a new topic namely the Metal-Oxide-Semiconductor Field Effect Transistor. Solid State Devices Dr. S. Karmalkar Department of Electronics and Communication Engineering Indian Institute of Technology, Madras Lecture - 38 MOS Field Effect Transistor In this lecture we will begin

More information

Structure of Speech. Physical acoustics Time-domain representation Frequency domain representation Sound shaping

Structure of Speech. Physical acoustics Time-domain representation Frequency domain representation Sound shaping Structure of Speech Physical acoustics Time-domain representation Frequency domain representation Sound shaping Speech acoustics Source-Filter Theory Speech Source characteristics Speech Filter characteristics

More information

Design of Micro robotic Detector Inspiration from the fly s eye

Design of Micro robotic Detector Inspiration from the fly s eye Design of Micro robotic Detector Inspiration from the fly s eye Anshi Liang and Jie Zhou Dept. of Electrical Engineering and Computer Science University of California, Berkeley, CA 947 ABSTRACT This paper

More information

STATION NUMBER: LAB SECTION: Filters. LAB 6: Filters ELECTRICAL ENGINEERING 43/100 INTRODUCTION TO MICROELECTRONIC CIRCUITS

STATION NUMBER: LAB SECTION: Filters. LAB 6: Filters ELECTRICAL ENGINEERING 43/100 INTRODUCTION TO MICROELECTRONIC CIRCUITS Lab 6: Filters YOUR EE43/100 NAME: Spring 2013 YOUR PARTNER S NAME: YOUR SID: YOUR PARTNER S SID: STATION NUMBER: LAB SECTION: Filters LAB 6: Filters Pre- Lab GSI Sign- Off: Pre- Lab: /40 Lab: /60 Total:

More information

Investigating Electromagnetic and Acoustic Properties of Loudspeakers Using Phase Sensitive Equipment

Investigating Electromagnetic and Acoustic Properties of Loudspeakers Using Phase Sensitive Equipment Investigating Electromagnetic and Acoustic Properties of Loudspeakers Using Phase Sensitive Equipment Katherine Butler Department of Physics, DePaul University ABSTRACT The goal of this project was to

More information

Co-Located Triangulation for Damage Position

Co-Located Triangulation for Damage Position Co-Located Triangulation for Damage Position Identification from a Single SHM Node Seth S. Kessler, Ph.D. President, Metis Design Corporation Ajay Raghavan, Ph.D. Lead Algorithm Engineer, Metis Design

More information

CHAPTER 5 FAULT DIAGNOSIS OF ROTATING SHAFT WITH SHAFT MISALIGNMENT

CHAPTER 5 FAULT DIAGNOSIS OF ROTATING SHAFT WITH SHAFT MISALIGNMENT 66 CHAPTER 5 FAULT DIAGNOSIS OF ROTATING SHAFT WITH SHAFT MISALIGNMENT 5.1 INTRODUCTION The problem of misalignment encountered in rotating machinery is of great concern to designers and maintenance engineers.

More information

Laser Speckle Reducer LSR-3000 Series

Laser Speckle Reducer LSR-3000 Series Datasheet: LSR-3000 Series Update: 06.08.2012 Copyright 2012 Optotune Laser Speckle Reducer LSR-3000 Series Speckle noise from a laser-based system is reduced by dynamically diffusing the laser beam. A

More information

Studies on free vibration of FRP aircraft Instruments panel boards

Studies on free vibration of FRP aircraft Instruments panel boards 89 Studies on free vibration of FRP aircraft Instruments panel boards E. Chandrasekaran Professor in Dept. of Civil Engineering, Crescent Engineering College 648 India. e-mail: sekharan@vsnl.net and K.

More information

Out-of-plane translatory MEMS actuator with extraordinary large stroke for optical path length modulation in miniaturized FTIR spectrometers

Out-of-plane translatory MEMS actuator with extraordinary large stroke for optical path length modulation in miniaturized FTIR spectrometers P 12 Out-of-plane translatory MEMS actuator with extraordinary large stroke for optical path length modulation in miniaturized FTIR spectrometers Sandner, Thilo; Grasshoff, Thomas; Schenk, Harald; Kenda*,

More information

Fatigue crack propagation in uniaxial loading and bending fatigue in 20 khz testing. Mohamed Sadek PhD Student Karlstad university

Fatigue crack propagation in uniaxial loading and bending fatigue in 20 khz testing. Mohamed Sadek PhD Student Karlstad university Fatigue crack propagation in uniaxial loading and bending fatigue in 20 khz testing Mohamed Sadek PhD Student Karlstad university 2017-02-08 EU - project Influence of cyclic frequency on fatigue strength

More information

6. LDD Design Tradeoffs on Latch-Up and Degradation in SOI MOSFET

6. LDD Design Tradeoffs on Latch-Up and Degradation in SOI MOSFET 110 6. LDD Design Tradeoffs on Latch-Up and Degradation in SOI MOSFET An experimental study has been conducted on the design of fully depleted accumulation mode SOI (SIMOX) MOSFET with regard to hot carrier

More information

Lab 12 Microwave Optics.

Lab 12 Microwave Optics. b Lab 12 Microwave Optics. CAUTION: The output power of the microwave transmitter is well below standard safety levels. Nevertheless, do not look directly into the microwave horn at close range when the

More information

Multi-field Microphone when the Sound Field is unknown

Multi-field Microphone when the Sound Field is unknown Multi-field Microphone when the Sound Field is unknown Svend Gade, Niels V. Bøgholm Brüel & Kjær Sound & Vibration A/S, Skodsborgvej 307 2850 Nærum, Denmark ABSTRACT Only a small percentage of all acoustical

More information

Applications area and advantages of the capillary waves method

Applications area and advantages of the capillary waves method Applications area and advantages of the capillary waves method Surface waves at the liquid-gas interface (mainly capillary waves) provide a convenient probe of the bulk and surface properties of liquids.

More information

An Alternative to Pyrotechnic Testing For Shock Identification

An Alternative to Pyrotechnic Testing For Shock Identification An Alternative to Pyrotechnic Testing For Shock Identification J. J. Titulaer B. R. Allen J. R. Maly CSA Engineering, Inc. 2565 Leghorn Street Mountain View, CA 94043 ABSTRACT The ability to produce a

More information

MICROPROCESSOR TECHNOLOGY

MICROPROCESSOR TECHNOLOGY MICROPROCESSOR TECHNOLOGY Assis. Prof. Hossam El-Din Moustafa Lecture 3 Ch.1 The Evolution of The Microprocessor 17-Feb-15 1 Chapter Objectives Introduce the microprocessor evolution from transistors to

More information

Underground M3 progress meeting 16 th month --- Strain sensors development IMM Bologna

Underground M3 progress meeting 16 th month --- Strain sensors development IMM Bologna Underground M3 progress meeting 16 th month --- Strain sensors development IMM Bologna Matteo Ferri, Alberto Roncaglia Institute of Microelectronics and Microsystems (IMM) Bologna Unit OUTLINE MEMS Action

More information

Chapter 12. Preview. Objectives The Production of Sound Waves Frequency of Sound Waves The Doppler Effect. Section 1 Sound Waves

Chapter 12. Preview. Objectives The Production of Sound Waves Frequency of Sound Waves The Doppler Effect. Section 1 Sound Waves Section 1 Sound Waves Preview Objectives The Production of Sound Waves Frequency of Sound Waves The Doppler Effect Section 1 Sound Waves Objectives Explain how sound waves are produced. Relate frequency

More information