Electrical Measuring Instruments. Vol.3.

Size: px
Start display at page:

Download "Electrical Measuring Instruments. Vol.3."

Transcription

1 Electrical Measuring Instruments GENERAL CATALOG ol.3

2 Contents Clamp Meters Insulation Testers Earth Tester Digital Multimeters Automotive Testers Other Testers Accessories Digital Clamp Meters Leakage Clamp Meters Digital Insulation Testers Analog Insulation Testers Handy-Type Probe Tester Bench-Top DMM All-in-one DMM Card-Type DMM Drop-Proof Tester Battery Checker Handy m Tester Digital Multimeters Digital Tachometer Low Clamp Meter O2 Sensor Checker Digital Sound Level Meter Digital Light Meter Triaxial ELF Magnetic Field Meter Digital Thermometer SK-7660 SK-7661 SK-7682 SK-7718 SK-7720 SK-7722 SK-7708 SK-7601 SK-7602 SK-7615 SK-7625 SK-7815 SK-7820 SK-7825 SK-3500 SK-3502 SK-3000 SK-3002 SK-3003 SK-3005 SK-3010 SK-3012 SK-30 SK-3016 SK-3320 KU-2600 KU-2602 SK-6161 SK-6163 SK-6150 SK-6597 SK-6598 SK-6592 SK-4033 SK-4035 SK-6555 KU-1199 SK-6500 SK-355 KF-32 KF-20 SK-8535 SK-3800 KT-2021 SK-6166 SK-8401 SK-7830 SK-8402 KG-70 KG-75 SK-8301 SK-6850 Temperature Probe / / / / 793 / 795 / / 940 / 946 / 949 / 818 / / 660 / 731 / 732 / 880 Standard Accessories (excerption) Mark Descriptions 34

3 Note the following WARNINGS and CAUTIONS when using Electric / Electronic Measuring Instruments. 1 Safety Symbols Caution Symbol on the instrument indicates that the user should read carefully the operating instructions in the manual. High oltage Warning Symbol on the instrument indicates that a potential of 1000 or more high voltage may be present on the Terminals. The user should use extreme care about safety practices. Maximum Allowable Ground oltage Symbol on the instrument indicates that the maximum voltage between INPUT Terminals and Earth Ground is 500 in this case. The user must not apply any voltage that will exceed the maximum voltage. 2 Warnings for High Power Line and High oltage Measurements The ordinary multimeters, analog or digital, are provided with maximum range of 500 to 1000 and. But, most of them are designed to measure Low Power Circuits such as Ts, Radios and home electrical apparatus. Therefore, to measure High Power Circuits or High Power Line more than 220, such as Power Supplies for Factory Equipments and Facilities, etc., do NOT use any ordinary multimeters. Use the instruments especially designed for High Power Line. High Power Line sometimes includes Surge oltage more than 10 times of the rated voltage. So, the Surge oltage will cause electric shock accidents when measuring with the ordinary multimeters. Even if the circuit to be measured is of Low Power, if the voltage is greater than 220, use the instruments with great care observing warnings and cautions written in the instruction manuals concerned. For Safety The International Safety Standard IEC61010 To ensure safe operation of measurement products, IEC establishes safety standards for various electrical environments, categorized as CATto CAT, and called measurement categories. These are defined as follows. CAT.Primary electrical circuits in equipment connected to an electrical outlet by a power cord (portable tools, household appliances, etc) CAT.Primary electrical circuits of heavy equipment (fixed installations) connected directly to the distribution panel, and feeders from the distribution panel to outlets. CAT.The circuit from the service drop to the service entrance, and to the power meter and primary over current protection device (distribution panel). Service wire CAT. Service entrance Watthour meter Distribution board Power receptacle CAT. Indoor wiring CAT. Power receptacle Higher-numbered categories correspond to electrical environments with greater momentary energy, so a measurement product designed for CAT environments can endure greater momentary energy than one designed for CAT. Using a measurement product in an environment designated with a higher-numbered category than that for which the product is rated rated could result in a severe accident, and must be carefully avoided. Never use a CATmeasuring product in CAT, or environments. The measurement categories comply with the Overvoltage Categories of the IEC Standards. Insulation Cap for Test Lead Kaise conforms to IEC (safety standard for hand-held probes) by using test lead caps. Required standards : Exposed metal part must be 4mm or shorter for CAT I and III environments to prevent short-circuits from occurring. No Cap attached For CAT environment Cap attached For CAT and environments CE Mark CE marking is a safety mark which can be attached only on a product meeting the safety requirements of the Directive of Council of the European Union (EC Directive). A product attached with the CE mark is designed so as to meet the requirements of the "Low oltage Directive" and "EMC Directive" of the EC Directive. Low oltage Directive: This Directive covers products of power supply voltage of () and (), and it defines electric safety requirements against shocks, burns, etc. The applicable standard is EN61010 corresponding to IEC1010 give on the left. EMC Directive: This Directive stipulates conditions so as not to give out strong electromagnetic waves from equipment to the outer environment and to protect equipment from the effect of electromagnetic waves from the outside. Traceability Chart Traceability to prove the compliance with national and international standards is an essential factor for measuring instruments used as test instruments associated with quality assurance. Products of Kaise are calibrated by reference samples which is periodically checked for its compliance with national standards. A calibration certificate and test data report are available on your request. National Standards National Institute of Advanced AIST Industrial Science and Technology Japan Electric Meters Inspection JEMIC Corporation National Institute of Information NICT and Communications Technology NIST National Institute of Standards and Technology Comparative Standards Calibration Standards High- Digital Multimeter LCR Meter Digital thermohygrometer Shunt Applied Standards oltage Temperature Humidity / Calibrated Parameters Measuring Instruments in R&D, Production, Inspection and Service Department

4 Clamp Meters Index Accessories Other Testers Automotive Testers Digital Multimeters Insulation Testers / Earth Tester Clamp Meters Model Display Counts oltage oltage Pulse Width Temperature True Auto Ranging Manual Ranging / Average Peak Hold Hold Difference Display Hold Power-On Initialize Comparator Low Pass Filter Output Terminal External Power Supply Dust Proof & Simple Water Resistant Auto Power Save (Off) 27mm 400 4k 40k 400k 4M 40M *1 27mm 400 4k 40k 400k 4M 40M *1 19mm *1 SK mm 400 4k 40k 400k 4M 40M *1 *1 : for measurement

5 Clamp Meters Index Digital Clamp Meters Model Display Counts oltage oltage Pulse Width Temperature True Auto Ranging Manual Ranging / Average Peak Hold Hold Difference Display Hold Power-On Initialize Comparator Low Pass Filter Output Terminal External Power Supply Dust Proof & Simple Water Resistant Auto Power Save (Off) SK mm k SK mm k SK mm 2000A 2000A 400 4k 40k 400k 4M 40M *1 27mm 300A 27mm 400 4k 40k 400k 4M 40M *1 : for measurement Clamp Meters Insulation Testers / Earth Tester Digital Multimeters Automotive Testers Other Testers Accessories

6 Clamp Meters Index Digital Clamp Meters Leakage Clamp Meters Accessories Other Testers Automotive Testers Digital Multimeters Insulation Testers / Earth Tester Clamp Meters Model Display Counts oltage oltage Pulse Width Temperature True Auto Ranging Manual Ranging / Average Peak Hold Hold Difference Display Hold Power-On Initialize Comparator Low Pass Filter Output Terminal External Power Supply Dust Proof & Simple Water Resistant Auto Power Save (Off) mm 2A 20A 200A 200m k 20k 200k 2M 20M * mm 2A 20A 200A 600A 200m k 20k 200k 2M 20M *2 SK mm 30mA 300mA 30A 60A 300 SK mm 40mA 400mA 100A *3 (with ibration) SK mm 40mA 400mA 100A *3 (with ibration) *2 : Two-ranges auto for A. *3 : ma / A : switch selection

7 Handy-size Clamps with Efficient 27mm Focused on High-Flexibility SK mm PEAK SK-7660 SK-7661 AUTO ZERO for measurement 15 measurement functions in one small package. "Power-On Initialize" (auto zero adjustment) in A. Rubber-molded rotary switch and trigger. Easy-to-clamp compact & beaked clamp head even for narrow conductors. True and peak hold (SK-7660), / (SK-7661) PEAK AUTO ZERO for measurement SK-7660 Display : count LCD, Maximum reading 4050 : 27mm Max. Power Supply : 1.5 R03 or AAA Batteries (x 2) CE Mark : CAT 300, CAT and EMC Dimensions : 170(H) x 58(W) x 27(D)mm Weight : 160g Accessories : Test Leads (x 1 set) 1015 Carrying Case (x 1) 1.5 R03 Batteries (x 2) for oltage measurement Usable for Automotive Measurements. Peak and Peak oltage. Max / Min and Difference Measurements. Display : count LCD, Maximum reading 4050 : 19mm Max. Power Supply : 1.5 R6P or AA Batteries (x 2) CE Mark : CAT 300 and EMC Dimensions : 196(H) x 59(W) x 30(D) mm Weight : 180g Accessories : Test Leads (x 1 set) (x 1 set) 1011 Carrying Case (x 1) 1.5 R6P Batteries (x 2) A / A A / A / / * 1.5rdg3dgt 40 to 200A 1.5rdg5dgt 201 to 300A 3.0rdg3dgt 301 to 4.0rdg3dgt 1.5rdg5dgt (50/60) 40 to 200A 201 to 300A 301 to 2.0rdg3dgt (50/60) 4.0rdg5dgt (50/60) 5.0rdg5dgt (50/60) 5 to 1k 0.2rdg2dgt 1.0rdg3dgt oltage 1.0rdg2dgt / / oltage 1.5rdg5dgt (40 to 400) 5 to 49.99k 0.2rdg2dgt 5 to rdg3dgt 400 4k 1.5rdg5dgt 0.7rdg3dgt 40k 1.2rdg5dgt 400k 3.0rdg5dgt 4M 40M 1.5rdg5dgt 5.0rdg5dgt rdg5dgt Buzzer Sound : Approx. 50 or less 0 to rdg5dgt Open Circuit oltage : / 500nF / 5 / 50 / 100F 5.0rdg10dgt Peak Hold (SK-7660), / (SK-7661), Difference, Power-on Initialize (for measurement), Display Hold, Auto Power OFF * Characteristic (40 to 400) : (0.5 to 9A) add 1.5 (10 to ) add 0.5 add 1.0 oltage oltage 5 to 1k 1 to 49.99k 0 to rdg3dgt 40 to 200A 2.0rdg3dgt 201 to 4.0rdg3dgt 1.5rdg5dgt 36 to 200A 2.0rdg5dgt 201 to 5.0rdg5dgt 0.2rdg2dgt 1.0rdg3dgt 1.0rdg2dgt 1.5rdg5dgt 0.2rdg2dgt 0.5rdg5dgt /, Peak Hold, Difference, Power-on Initialize (for measurement), Display Hold, Auto Power Off Clamp Meters Insulation Testers / Earth Tester Digital Multimeters Automotive Testers Other Testers Accessories

8 ersatile Clamp Meter, Compactly Designed Clamp Meters 35mm PEAK SK-7718 AUTO ZERO for measurement Dust Proof Simple Water Resistant Accessories Other Testers Automotive Testers Digital Multimeters Insulation Testers / Earth Tester 36mm SK-7720 / Measurements "Power-On Initialize" (auto zero adjustment) for A. /, Difference, Peak Hold Dust-proof case is used to protect the tester from dust damage. Display : count LCD, Maximum reading 9999 : 35mm Max. Power Supply : 9 6F22 Battery (x 1) CE Mark : CAT and EMC Dimensions : 193(H) x 60(W) x 34.5(D) mm Weight : 300g Accessories : Test Leads (x 1 set) 1012 Carrying Case (x 1) 9 6F22 Battery (x 1) PEAK SK Channel Measurements on Dual Display LCD and Oscilloscope Connection A A Temperature OUT PUT SK Temperature Probe 922 Adapter Cable 930 Output Cord for Recorder (SK-7722) / 650 / 10.0 to 0.0 to mS to 999.9mS / 650 PULSE WIDTH Simple Water Resistant SK-7722 Two different elements can be measured at once and read on a bigger Dual Display LCD. Analog Output Terminal for an Oscilloscope or Recorder (SK-7722). Dust-proof case is used to protect the tester from dust damage. oltage Pulse Width oltage Pulse Width Dust Proof SK A 400 to 600A 601 to 1.0rdg3dgt 1.0rdg1dgt 1.5rdg3dgt 1.5rdg1dgt 3.0rdg3dgt 50 to rdg3dgt 1.5rdg1dgt 3.0rdg3dgt 400.0A 400 to 600A 601 to 0.5rdg1dgt 3.0rdg3dgt 0.5rdg3dgt 1.0rdg3dgt (50 to 60) 1.5rdg3dgt (40 to 400) 0.5rdg1dgt 3.0rdg3dgt 0.5rdg3dgt 1.0rdg3dgt 1.0rdg1dgt A / A / to 0.0 to mS to 999.9mS 20k 30 to rdg3dgt Peak Hold, /, Difference, Display Hold, Output Terminal (SK-7722) oltage oltage / rdg5dgt 400 to 600A 1.5rdg5dgt 601 to 3.0rdg5dgt 1.5rdg3dgt 400 to 600A 1.5rdg3dgt 601 to 3.0rdg3dgt 0.2rdg2dgt 1 to 1k 1.0rdg5dgt (40 to 400) 1.0rdg3dgt 1 to 0.2rdg2dgt 49.99k 10 to rdg2dgt rdg5dgt 4k 40k 1.0rdg3dgt 400k 4M 4.0rdg5dgt 40M 6.0rdg5dgt 400Buzzer Sound : Approx. 50or less) 0 to rdg5dgt Open Circuit oltage : / 500nF / 5 / 50 / 100F 5.0rdg10dgt Peak Hold, /, Difference, Power-on Initialize (for measurement), Display Hold,Auto Power OFF Display : count LCD, Maximum reading 9999 Sampling Rate : 15 times / sec. (each channel), 3.75 times / sec. for A measurements in ordinary mode. : 36mm Max. Power Supply : 9 6F22 or NEDA 1604 Battery (x 1) Dimensions : 200(H) x 64(W) x 33(D) mm Weight : 310g Accessories : Test Leads (x 1 set) 1007 Carrying Case (x 1), 9 6F22 Battery (x 1) SK rdg3dgt 1.0rdg1dgt 40 to rdg3dgt 2.5rdg1dgt 4.0rdg3dgt 1.0rdg3dgt (50 to 60) 1.5rdg3dgt (40 to 400)

9 Powerful for Every Measurement 55mm Digital Clamp Meters Pocket-sized Clamp Meter 27mm 2000A PEAK SK-7708 RNG APS "Power-On Initialize" (auto zero adjustment) for A. Peak Hold, / measurements. Dust-proof case is used to protect the tester from dust damage. A / A / AUTO ZERO for measurement 2000A 2000A 1 to 4.999k oltage oltage 300A / / / / / / / 1 to 100k 0.1 to k / 40k / 400k 4M 40M 400 Buzzer Sound : Approx. 50 or less Dust Proof 0 to 1001A or more 1.5rdg5dgt 0.2rdg2dgt 40 to rdg5dgt 1.2rdg3dgt 0.2rdg2dgt 2.0rdg2dgt 1.5rdg5dgt 1.0rdg3dgt 3.0rdg4dgt 5.0rdg7dgt 1.5rdg5dgt Simple Water Resistant Display : count LCD, Maximum reading 5120 Selection : Auto / Manual Ranging : 55mm Max. Power Supply : 9 6F22 Battery (x 1) CE Mark : CAT and EMC Dimensions : 250(H) x 92(W) x 39(D) mm Weight : 500g Accessories : Test Leads (x 1 set) 1007 Carrying Case (x 1) 9 6F22 Battery (x 1) 50 to rdg5dgt 1.5rdg5dgt 3.0rdg5dgt 401 to 1K 3.0rdg5dgt 40 to 1k 3.0rdg5dgt 3.0rdg5dgt 0 to rdg5dgt Open Circuit oltage : / 500nF / 5 / 50 / 100F 5.0rdg10dgt /, Peak Hold, Difference, Power-on Initialize (for measurement), Hold, Display Hold, Auto Power Save Simple operation. Strong and beaked Clamp Head against twists. AUTO POWER OFF : turns off automatically after 12 minutes. Full Auto Ranging up to 300A. LAY Function. With Carrying Case. OPTIONAL CESSORY Display : count LCD, Maximum reading Sampling Rate : 2.5 times / sec : 27mm Max. Power Supply : 3 CR2032 Battery (x 1) CE Mark : CAT 300 and EMC Dimensions : 150(H) x 52(W) x 24(D)mm Weight : 110g Accessories : 1004 Carrying Case (x 1) 3 CR2032 Battery (x 1) 300A Display Hold, Auto Power OFF 1.8rdg5dgt Clamp Meters Insulation Testers / Earth Tester Digital Multimeters Automotive Testers Other Testers Accessories

10 Digital Clamp Meters Multi-functional Handy Clamp with Long Battery Life Clamp Meters Insulation Testers / Earth Tester Digital Multimeters 27mm 220-hours long time measurement. (with alkaline cells) measurement functions in one small package. Rubber-molded rotary switch and trigger. Easy-to-clamp compact & beaked clamp head even for narrow conductors. True, / and Difference measurement. Display : count LCD, Maximum reading 4050 : 27mm Max. Power Supply : 1.5 R03 or AAA Batteries (x 2) CE Mark : CAT 300, CAT and EMC Dimensions : 171(H) x 58(W) x 27(D)mm Weight : 140g Accessories : Test Leads (x 1 set) 1015 Carrying Case (x 1) 1.5 R03 Batteries (x 2) A / / / oltage oltage 1.5rdg5dgt (50/60) 3.0rdg5dgt (40 to 400) 0.2rdg2dgt 1.0rdg3dgt 5 to 1k 1.0rdg2dgt 5 to 0.2rdg2dgt 49.99k 5 to rdg3dgt rdg5dgt 4k 40k 0.7rdg3dgt 400k 4M 1.2rdg5dgt 40M 3.0rdg5dgt rdg5dgt Buzzer Sound : Approx. 50 or less 0 to rdg5dgt Open Circuit oltage : / 500nF / 5 / 50 / 100F 5.0rdg10dgt /, Difference, Display Hold, Auto Power OFF 1.5rdg5dgt (40 to 400) Easy & Useful Easy - to - Clamp SK-7602's compact and beaked clamp heads assure easy clamping even for narrow conductors. 27mm Avoid Your Fingers Slips SK-7602 are always fit on your hand. Double-Molding Rubbers on a Function Switch and a Trigger avoid your fingers slips during operation. Test Lead Holder Fixable Test Lead on the side of SK-7602 by inserting its hook into the holder socket. Useful for oltage,, Measurements, Continuity and s. Automotive Testers High Quality Clamp Meter that contains DMM functions 26mm SK mm SK-7625 SK-7615 SK A SK-7615SK-7625 Other Testers Accessories SK-7615 Round Clamp Head opens two ways at slant position assures accuracy and easy use. Easy Operation with Rotary Switch. Wide Measurement s. Display : 2000 count LCD, Maximum reading 1999 (two-ranges auto for A) : SK-7615 :26mm Max. SK-7625 :42mm Max. Power Supply : 1.5 LR-44 Batteries (x 2) Dimensions : SK-7615 : 171(H) x 72(W) x 35(D) mm SK-7625 : 183(H) x 78(W) x 35(D) mm Weight : SK-7615 : 180gSK-7625 : 210g Accessories : Test Leads (x 1 set) 983 Carrying Case (x 1) 1.5 LR-44 Batteries (x 2) (SK-7615) (SK-7625) 2A/20A 200A/ 2A/20A 200A/600A 2A 20A 200A 2A 20A 200A 600A 5.0rdg10dgt 2.0rdg7dgt 1.5rdg7dgt 5.0rdg10dgt 2.0rdg7dgt 1.5rdg7dgt oltage 2/20/200/ 1.0rdg5dgt 200m 0.5rdg2dgt oltage 2/20/ rdg2dgt 1.0rdg2dgt 200/2k/20k/200k 1.5rdg5dgt 2M 3.0rdg5dgt 20M 5.0rdg5dgt Continuity 200Buzzer Sound : Approx. 60or less) Test rdg3dgt Open Circuit oltage : 1.7 Display Hold, Auto Power OFF

11 Leakage Clamp Meters Leakage Clamp with Comparator The World's First ibration Alert Comparator Installed 100A COMP LPF 24mm SK mm SK mm 60A Easy to read LCD. Comparator : 1mA to 20mA setting. Buzzer sounds when measured value exceeds the set point. Max / Min Measurement. Low Pass Filter cuts off frequencies higher than 150. Display Hold & Auto Power Save. Power Hold enables longer measurements. CE Mark is approved, EMC and LD (IEC ) passed. Display : 3200 count LCD, Maximum reading 3200 Sampling Rate : 2 times / sec : 30mm Max. Power Supply : 1.5 R6P or AA Batteries (x 2) CE Mark : CAT 300 and EMC Dimensions : 212(H) x 42(W) x 30(D) mm Weight : 220g Accessories : Test Leads (x 1 set) 1011 Carrying Case (x 1) 1.5 R6P Batteries (x 2) SK-7820SK-7825 Wide range from 40mA to 100A. ibration and buzzer comparator convenient in noisy surroundings. Low pass filter (cutoff 150 or more) 100-hours continuous measurement (with alkaline cells) Rubber-molded rotaty switch and trigger neatly fit in your hand. COMP oltage LPF SK-7815 Advantages of SK-7820 / 7825 (50/60) 0.10mA to 1.00mA 1.0rdg7dgt 40mA / 400mA 1.01mA or more 1.0rdg5dgt 0.10A to 1.00A 2.0rdg7dgt 1.01A or more 2.0rdg5dgt 40.1A to 80.0A 2.0rdg5dgt 100A 80.1A to 100.0A 4.0rdg5dgt 5.0 to rdg7dgt / 10.1 or more 2.0rdg5dgt ibration alert comparator, Low pass filter, Display Hold, Auto Power OFF ibration Alert Comparator SK-7820 / 7825 incorporate Comparator Function in ma range. Buzzer sounds and vibrates if measuring value exceeds the setting value. Even in noisy surroundings, that can drown out the buzzer sound, vibration helps your comparator measurement. (ibration alert is cancelable.) oltage 30mA 300mA 30A 60A 300 / Display : count LCD, Maximum reading 4050 Sampling Rate : 2 times / sec (ma / A : switch selection) : SK-7820:24mm Max., SK-7825:40mm Max. Power Supply : 1.5 (L) R03 or AAA Batteries (x 2) CE Mark : CAT 300, CAT and EMC Dimensions : SK-7820:168(H) x 58(W) x 27(D) mm SK-7825:184(H) x 58(W) x 27(D) mm Weight : SK-7820:170g, SK-7825:180g Accessories : Test Leads (x 1 set) 1020 Carrying Case (x 1), 1.5 LR03 Batteries (x 2) Filter ON (50/60) add 1.0rdg3dgt add 1.0rdg3dgt Characteristic (40 to 400) add 1.0rdg3dgt add 1.0rdg3dgt Two-types-of Clamp Head SK-7820's small clamp head assures easy clamping even for narrow conductors. SK-7825's large clamp head is suitable for thick conductors' measurement like 3-phase 3-wire system. 24mm Max 1.0rdg5dgt 1.5rdg5dgt 0A to 27.0A 1.5rdg5dgt 27.1A to 50.00A 2.0rdg5dgt 50.1A to 60.0A 5.0rdg5dgt 2.0rdg5dgt /, Comparator (up to 20mA), Low pass filter, Display Hold, Auto Power Save 40mm Max Clamp Meters Insulation Testers / Earth Tester Digital Multimeters Automotive Testers Other Testers Accessories SK-7825 SK-7820 SK-7820 SK-7825

MS2030 CAT III 600 V A V AUTO RS232

MS2030 CAT III 600 V A V AUTO RS232 MS2030 AC Digital Clamp Meter User s Manual CAT III 600 V AUTO RS232 A V CONTENTS 1.Introduction...1 2.Safety Information...1 2.1 Precautions...1 2.2 Safety Symbols...3 3. Description...4 3.1 Front Panel...4

More information

ET-3888 True RMS Clamp Meter. User Manual

ET-3888 True RMS Clamp Meter. User Manual ET-3888 True RMS Clamp Meter User Manual Index Introduction... 3 Safety Notes... 4 Features... 5 Specifications... 6-8 Instrument Layout... 9 Measurement... 10 Maintenance... 11 Page 2 1. Introduction

More information

AC/DC CLAMP METER USER S MANUAL

AC/DC CLAMP METER USER S MANUAL AC/DC CLAMP METER USER S MANUAL CONTENTS PAGE SAFETY INFORMATION SYMBOL EXPLANATION SAFETY PRECAUTIONS 1 1 2 MAINTENANCE 3 GENERAL DESCRIPTION 4 PANEL DESCRIPTION 4 OPERATING INSTRUCTIONS... 7 SPECIFICATIONS

More information

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The Frequency Selector Switch How to Use Data Hold Function

More information

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use http://www.all-sun.com EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL V Read this owners manual thoroughly before use WARRANTY This instrument is warranted to be free from defects in material and workmanship

More information

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The Frequency Selector Switch How to Use Data Hold Function

More information

4-range High voltage insulation resistance tester KEW 3126

4-range High voltage insulation resistance tester KEW 3126 INSTRUCTION MANUAL 4-range High voltage insulation resistance tester KEW 3126 Contents 1. Safety warnings 1 2. Feature 5 3. Specification 6 4. Instrument layout 4-1 Instrument layout 9 4-2 LCD display

More information

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions CONTENTS [1] SAFETY PRECAUTIONS: Before use, read the following safety precautions 2 [2] APPLICATION AND FEATURES 5 [3] NAME OF COMPONENT UNITS 6 [4] DESCRIPTION OF FUNCTIONS 8 [5] MEASUREMENT PROCEDURE

More information

400Amp True RMS AC Clamp Meter + NCV

400Amp True RMS AC Clamp Meter + NCV User Guide 400Amp True RMS AC Clamp Meter + NCV Model MA410T Introduction Thank you for selecting the Extech MA410 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,

More information

DIGITAL / ANALOG HiTESTER SERIES

DIGITAL / ANALOG HiTESTER SERIES DIGITAL / ANALOG HiTESTER SERIES Multi Meters A Full Line-up of Digital and Analog Multimeters Suit Any Need From Basic Testing High Performance Analysis 2 POCKET SIZE DMM SERIES New product information

More information

Dawson DDM190. Digital Multimeter User s Manual

Dawson DDM190. Digital Multimeter User s Manual Dawson DDM190 Digital Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories.. Error! Bookmark not defined. Safety Information... 7

More information

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A TABLE OF CONTENTS TITLE PAGE Safety Information Safety Symbols... 1 Meter Description...

More information

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH AC/DC LOW CURRENT CLAMP-ON METER CM605 ENGLISH User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments

More information

DMM8900 SERIES USERS MANUAL

DMM8900 SERIES USERS MANUAL DMM8900 SERIES USERS MANUAL WARRANTY This instrument is warranted to be free from defects in material and workmanship for a period of one year. Any instrument found defective within one year from the delivery

More information

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL Table of Contents 1 SAFETY PRECAUTIONS Before use, read the following safety precautions.- 1-1 Explanation of Warning Symbols 001 1-2 Warning Messages for Safe

More information

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D T8211D 1 1. SAFETY INFORMATION BE EXTREMELY CAREFUL IN THE USE OF THIS METER. Improper use of this device can result in electric shock or destroy of

More information

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER User Manual Gebruikershandleiding Manuel d'utilisation Gebrauchsanleitung Introduction BENCH MULTIMETER This manual

More information

200Amp AC Clamp Meter + NCV Model MA250

200Amp AC Clamp Meter + NCV Model MA250 User's Guide 200Amp AC Clamp Meter + NCV Model MA250 Introduction Congratulations on your purchase of this Extech MA250 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance,

More information

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS CONTENTS MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 2 1.2 DURING USE 3 1.3 SYMBOLS 5 1.4 MAINTENANCE 6 2. DESCRIPTION 8 2.1 NAMES OF COMPONENTS 9

More information

DIGITAL / ANALOG HiTESTER SERIES

DIGITAL / ANALOG HiTESTER SERIES DIGITAL / ANALOG HiTESTER SERIES Multi Meters A Full Line-up of Digital and Analog Multimeters Suit Any Need From Basic Testing High Performance Analysis 2 A Complete HIOKI Digital Multimeter Line-up Suit

More information

AMM-1022 Digital Multimeter USER`S MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement

More information

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need CLAMP ON HiTESTER SERIES Field measuring instruments A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need From Basic Testing to High Performance Analysis 2 Selection Guide A Complete HIOKI

More information

OPERATOR S INSTRUCTION MANUAL

OPERATOR S INSTRUCTION MANUAL 2 OPERATOR S INSTRUCTION MANUAL CLAMP METER HOLD 20 A 200 A 2 A 600 600 LIGHT ON/OFF Digital Clamp Meter 2 20 200 A khz COM CAT.II MAX 600 CONTENTS 1. General instruction.....1 2. Description...1 2.1 Precautions

More information

Pen-type DIGITAL MULTITESTER

Pen-type DIGITAL MULTITESTER BST-MT267 Pen-type DIGITAL MULTITESTER INSTRUCTION MANUAL Index 1. Introduction... 2. Safety Notes... 3. Features... 4. Specifications... 5. General... 6. Instrument Layout... 7. Measurement... 8. Maintenance...

More information

8PK-ST1520 Digital Earth Resistance Tester

8PK-ST1520 Digital Earth Resistance Tester 8PK-ST1520 Digital Earth Resistance Tester Users Manual Index 1.INTRODUCTION... 2.SAFETY NOTES... 3.FATURES... 4.SPECIFICATIONS... 5.LAYOUT... 6.MEASURING METHODS... 7.MAINTENANCE... Page 1 2 3 4 5 6-7

More information

Digital Multi Meter OPERATING INSTRUCTION. Table of Contents

Digital Multi Meter OPERATING INSTRUCTION. Table of Contents Table of Contents Digital Multi Meter OPERATING INSTRUCTION 1. Introduction 2. Safety note 3. Explanation of Controls and Indicators 3-1. Product illustration 3-2. Functional push button 3-3. LCD display

More information

AC/DC Current Oscilloscope Probe Model SL261

AC/DC Current Oscilloscope Probe Model SL261 AC/DC Current Oscilloscope Probe Model SL261 USER MANUAL I ZERO 100 mv/a 10 mv/a OFF Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

Digital Clamp Meter. User Manual

Digital Clamp Meter. User Manual Digital Clamp Meter User Manual CM240 WWW.OWON.COM.CN Mar. 2016 edition V1.2 Copyright LILLIPUT Company. All rights reserved. The LILLIPUT's products are under the protection of the patent rights, including

More information

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters Africa 1 & 2 Indianapolis Street Kyalami Business Park Kyalami, Midrand, South Africa Asia 460 Alexandra Road, #15-01A PSA Building Singapore 119963 Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

More information

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual Dawson DDM181 Pocket-Size Autorange Digital Meter User s Manual 1 Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Important Safety Information...

More information

IDM 98-III & IDM 99-III Digital Multimeters

IDM 98-III & IDM 99-III Digital Multimeters Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters IDM 99-III SECTION 1 SAFETY INFORMATION Safety Information Understand and follow operating instructions carefully. Use the instrument only

More information

Measure voltage without test leads. Product Highlights

Measure voltage without test leads. Product Highlights Measure voltage without test leads Measure voltage up to 1000 V ac through the open fork, without test lead contact to live voltage. + Without opening covers or removing wire nuts. On wires up to AWG 4/0

More information

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com USER'S MANUAL ACDC-100 TRMS ACDC-100 Versatile AC/DC Clamp-on Multimeter Series 1 1) SAFETY This manual contains information

More information

BENNING. CM7 Electrical Tester. Service Information

BENNING. CM7 Electrical Tester. Service Information BENNING CM7 Electrical Tester Service Information TABLE OF CONTENTS Page Introduction 1 Precautions and Safety Information 1 Symbols 1 Safety 2 Specifications 3 General Specification 3 Voltage Specification

More information

400Amp True RMS AC/DC Clamp Meter Model EX613

400Amp True RMS AC/DC Clamp Meter Model EX613 User's Guide 400Amp True RMS AC/DC Clamp Meter Model EX613 Introduction Congratulations on your purchase of this Extech EX613 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage,

More information

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER Model: Pro95 TRUE RMS MILLIAMP CLAMP METER TABLE OF CONTENTS 1. SAFETY INFORMATION... 1 2. GENERAL SPECIFICATION... 1 3. ELECTRICAL SPECIFICATION... 2 3-1 ACMA MEASUREMENT... 2 3-2 ACA MEASUREMENT...

More information

Insulation Testers and Earth Ground Testers

Insulation Testers and Earth Ground Testers Insulation Testers and Earth Ground Testers With a 5000 V MegOhmMeter for industrial-strength insulation testing and a range of compact hand-held instruments, we offer a solution for every troubleshooting

More information

User Manual Digital Clamp Multimeter. model no.: MSR-C600

User Manual Digital Clamp Multimeter. model no.: MSR-C600 User Manual Digital Clamp Multimeter model no.: MSR-C600 Overview This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings

More information

AC/DC Current Probes Model MR411 Model MR521

AC/DC Current Probes Model MR411 Model MR521 AC/DC Current Probes Model MR411 Model MR521 USER MANUAL OL OL ON ON 600V CAT III - 600A 600V CAT III - 1500A 60A 600A OFF 150A 1500A OFF! OUTPUT: 600A: 1 mv/a 60A: 10 mv/a! OUTPUT: 1500A: 1 mv/a 150A:

More information

SAFETY PRECAUTIONS: Before use, read the following safety precautions

SAFETY PRECAUTIONS: Before use, read the following safety precautions [1] SAFETY PRECAUTIONS: Before use, read the following safety precautions This instruction manual explains how to use your multimeter CD731, CD751 safely. Before use, please read this manual thoroughly.

More information

Ior DIGITAL LEAKAGE CLAMP TESTER MCL-400IR INSTRUCTION MANUAL

Ior DIGITAL LEAKAGE CLAMP TESTER MCL-400IR INSTRUCTION MANUAL Ior DIGITAL LEAKAGE CLAMP TESTER MCL-400IR INSTRUCTION MANUAL Thank you very much for selecting our model MCL-400IR Ior Leakage Clamp Tester. Before use the instrument, read this instruction manual completely

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com #61-732 #61-736 400 AAC Clamp Meter Instruction Manual AC HOLD APO DC KMΩ mva WARNING Read First: Safety Information Understand

More information

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols

More information

User Manual Digital Multimeter. model no.: MSR-U1000

User Manual Digital Multimeter. model no.: MSR-U1000 User Manual Digital Multimeter model no.: MSR-U1000 This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation

More information

Model 77 Series IV. Digital Multimeter. Users Manual

Model 77 Series IV. Digital Multimeter. Users Manual Model 77 Series IV Digital Multimeter Users Manual Model 77 Series IV Digital Multimeter The Fluke Model 77 Series IV is a battery-powered, average responding-rms indicating multimeter (hereafter "the

More information

FlexProbe FLEXIBLE AC CURRENT PROBE. User Manual. FlexProbe ON OL 1000V CAT III 300A 3000A OFF

FlexProbe FLEXIBLE AC CURRENT PROBE. User Manual. FlexProbe ON OL 1000V CAT III 300A 3000A OFF I N S T R U M E N T S FLEXIBLE AC CURRENT PROBE FlexProbe 24-3001 ON OL 1000V CAT III 300A 3000A OFF FlexProbe 24-3002 E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC

More information

79/26 Series III Multimeter

79/26 Series III Multimeter 79/26 Series III Multimeter Instruction Sheet W Read First: Safety Information Never use the meter if the meter or test leads look damaged. Be sure the test leads and switch are in the correct position

More information

DDM350 Pen-Type Digital Multimeter User s Manual

DDM350 Pen-Type Digital Multimeter User s Manual DDM350 Pen-Type Digital Multimeter User s Manual CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY....1 Out of the Box...1 Accessories......2 Safety Information...2 Safety Symbols...3 Certification......4

More information

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual Dawson DDM230C True RMS Multimeter with Bar Graph Display User s Manual Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Safety Information... 4

More information

DIGITAL CLAMP METER Use s Manual

DIGITAL CLAMP METER Use s Manual MS2026 MS2026R DIGITAL CLAMP METER Use s Manual MS2026 FUNC. RANGE MAX/MIN Hz/% HOLD AC CLAMP METER Auto Range AUTO DC AC MAX MIN REL μnf %Hz kmω mva CAT III 600 V CONTENTS 1. Safety Information...1 1.1

More information

MW3105 DIGITAL CLAMP MULTIMETER

MW3105 DIGITAL CLAMP MULTIMETER MW3105 DIGITAL CLAMP MULTIMETER 2 M MW3105 A 01 INTRODUCTION 1.1 - Unpacking and inspection Upon removing your new Digital Clamp Meter from its packing, you should have the following items: 1. Digital

More information

80i-110s AC/DC CURRENT PROBE

80i-110s AC/DC CURRENT PROBE Table of Contents 3 80i-110s AC/DC CURRENT PROBE Users Manual November 1996 1994, 1996 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. Printed in

More information

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at USER MANUAL Model MA150 200A AC Mini Clamp-on Meter Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA150 AC Mini Clamp Meter. This device

More information

User Manual 4 wire Earth Resistance Tester Model GRT300

User Manual 4 wire Earth Resistance Tester Model GRT300 User Manual 4 wire Earth Resistance Tester Model GRT300 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of Extech s 4 Wire Earth Resistance

More information

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

User s Guide. Model MA A AC Mini Clamp-on Meter

User s Guide. Model MA A AC Mini Clamp-on Meter User s Guide Model MA150 200A AC Mini Clamp-on Meter Introduction Congratulations on your purchase of Extech s MA150 AC Mini Clamp Meter. This meter is shipped fully tested and calibrated and, with proper

More information

COMPLY WITH HI-VOLTAGE PHASE CURRENT MEASUREMENT M-140HC INSTRUCTION MANUAL

COMPLY WITH HI-VOLTAGE PHASE CURRENT MEASUREMENT M-140HC INSTRUCTION MANUAL COMPLY WITH HI-VOLTAGE PHASE CURRENT MEASUREMENT CLAMP LEAKER M-140HC INSTRUCTION MANUAL Thank you very much for selecting our M-140HC Clamp Leaker complying with hi-voltage line current measurement. This

More information

323/324/325 Clamp Meter

323/324/325 Clamp Meter 323/324/325 Clamp Meter Users Manual May 2012 Rev.1, 06/15 2012-2015 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their

More information

EARTH RESISTANCE TESTER

EARTH RESISTANCE TESTER 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com DIGITAL BST-ET52 EARTH RESISTANCE TESTER INSTRUCTION MANUAL Index 1. Introduction...

More information

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL Ω CONTENTS CONTENTS 1. SAFETY INFORM...1 4.4 Range Transform...10 1.1 Preliminary...1 4.5 Auto Power Off...10 1.2 During use...2 4.6 Preparation For Measurement...11

More information

Amp Clamp W/True RMS

Amp Clamp W/True RMS 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 61746 600 Amp Clamp W/True RMS Ideal Catalog Number 61746 Manufacturer Ideal Ideal, Clamp Meter, Clamp-Pro, 600 Amp With

More information

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free User Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 4 wire Earth Resistance Tester Model GRT300 Introduction Congratulations

More information

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10 CONTENTS 1. SAFETY INFORMATION.1 2. DESCRIPTION..4 3. SPECIFICATIONS.6 4. OPERATING INSTRUCTION..9 4.1 Voltage measurement...10 4.2 Current measurement 10 4.3 Resistance measurement...12 4.4 Diode test.12

More information

374 FC/375 FC/376 FC Clamp Meter

374 FC/375 FC/376 FC Clamp Meter 374 FC/375 FC/376 FC Clamp Meter PN 4705494 September 2015 2015 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective

More information

IDM 503 & 505 Digital Multimeters

IDM 503 & 505 Digital Multimeters Instruction Manual IDM 503 & 505 Digital Multimeters IDM 505 SECTION 1 SAFETY INFORMATION Safety Information Understand and follow operating instructions carefully. Use the Instrument only as specified

More information

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com Model ST-9933 True RMS Autoranging Digital Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-8 Technical...4-5 Accuracy...5-8 Display Description...

More information

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution

More information

A Clamp W/TRMS

A Clamp W/TRMS 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 61763 660A Clamp W/TRMS Ideal Catalog Number 61763 Manufacturer Ideal Ideal, Clamp Meter, Tightsight, 760 Series With

More information

DIGITAL MULTIMETER INSTRUCTION MANUAL

DIGITAL MULTIMETER INSTRUCTION MANUAL DIGITAL MULTIMETER INSTRUCTION MANUAL 1 CONTENTS CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 1 1.2 DURING USE 2 1.3 SYMBOLS 3 1.4 MAINTENANCE 4 2. DESCRIPTION 5 2.1 NAMES OF COMPONENTS 5 2.2 SWITCH,

More information

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER MANUAL 600A AC Clamp Meter + NCV Model MA610 USER MANUAL 600A AC Clamp Meter + NCV Model MA610 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA610 Clamp Meter. This meter measures

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need

A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need CLAMP ON HiTESTER SERIES Field measuring instruments A Full Line-up of Digital and Analog Clamp Meters to Suit Any Need From Basic Testing to High Performance Analysis 2 Selection Guide A Complete HIOKI

More information

NOTE: Fully read and understand this manual before using this Digital Multimeter.

NOTE: Fully read and understand this manual before using this Digital Multimeter. ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-352 The Service Information provides the following information: Precautions and safety information Specifications Basic maintenance (cleaning, replacing

More information

1587/1577 Insulation Multimeters

1587/1577 Insulation Multimeters 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

Model : OPERATING MANUAL Table of Contents (1)

Model : OPERATING MANUAL Table of Contents (1) Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Measurement Operation A. DC

More information

DIGITAL HiTESTER. Instruction Manual

DIGITAL HiTESTER. Instruction Manual 3801-0 DIGITAL HiTESTER Instruction Manual i Contents Contents Introduction...1 Verifying Package Contents...1 Safety Information... Operating Precautions... 1 Overview 7 1.1 Product Overview...7 1. Features...8

More information

Digital Clamp Meter (TRMS) Model : 2727

Digital Clamp Meter (TRMS) Model : 2727 Digital Clamp Meter (TRMS) Model : 2727 Instruction Manual 1. SPECIFICATIONS 1.1 General Specifications Display : 3 ¾ digit liquid crystal display (LCD) with a maximum reading of 3999. Polarity : Automatic,

More information

INSTRUCTION MANUAL CLAMP ON PROBE

INSTRUCTION MANUAL CLAMP ON PROBE INSTRUCTION MANUAL 3275 CLAMP ON PROBE Contents Introduction 1 Inspection 1 Notes on Safety 1 Notes on Use 4 Chapter 1 Overview 9 1.1 Product Overview 9 1.2 Features 9 1.3 Names of Parts 10 1.4 Parts

More information

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual DUAL DISPLAY DIGITAL MULTIMETER User s Manual MS8250D 1. Safety Information Warning Use caution and follow all safety guidelines to prevent electric shock or damage to the meter. Please ready carefully

More information

M-1000D DIGITAL MULTIMETER

M-1000D DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER M-1000D Elenco Electronics, Inc. 150 Carpenter Avenue Wheeling, IL 60090 (847) 541-3800 Website: www.elenco.com e-mail: elenco@elenco.com Copyright 2008

More information

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325 AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325 CONTENTS 1. FEATURES... 2 2. Safety precaution... 2 Symbols Description... 3 3. Specifications... 4 4. Electrical Specifications...

More information

Pince Multimètre - Courants de fuites Leakage Clamp-on Meter Multimeter und Fehlerstrom-Messzange Pinza Multimetro - Correnti di fuga

Pince Multimètre - Courants de fuites Leakage Clamp-on Meter Multimeter und Fehlerstrom-Messzange Pinza Multimetro - Correnti di fuga Pince Multimètre - Courants de fuites Leakage Clamp-on Meter Multimeter und Fehlerstrom-Messzange Pinza Multimetro - Correnti di fuga Pinza Multímetro - Corrientes de fugas F 62 F 65 FRANÇAIS ENGLISH DEUTSCH

More information

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL AC/DC DIGITAL CLAMP METER OPERATION MANUAL HYS005661 A0 ACCESSORIES 6. ACCESSORIES 1) Test Leads: Electric Ratings 1000V 10A 1 pair (set) 2) Operating Manual 1 copy 3) 1.5V AAA Battery 3 piece - - 55 -

More information

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL

RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL RAGU 81D DIGITAL MULTIMETER OPERATION MANUAL Contents I. General...- 1 - Ⅱ. Open-package Inspection...- 2 - III. Safety Considerations... - 3 - IV.Instrument Panel & Button Function Description...- 9 -

More information

UT207A/208A/209A Operating Manual. Table of Contents

UT207A/208A/209A Operating Manual. Table of Contents Table of Contents Title Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Display Symbols Functional Buttons The Effectiveness

More information

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free User s Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting

More information

DIGIT & POINTER MULTIMETER

DIGIT & POINTER MULTIMETER CONTENTS DIGIT & POINTER MULTIMETER OPERATOR S MANUAL 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 1 1.2 DURING USE 2 1.3 SYMBOLS 3 1.4 MAINTENANCE 3 2. DESCRIPTION 4 2.1 NAMES OF COMPONENTS 4 2.2 FUNCTION

More information

Model UT511 OPERATING MANUAL

Model UT511 OPERATING MANUAL Model UT511 OPERATING MANUAL TITLE PAGE Introduction Unpacking the Meter Safety Information International Electrical Symbols Battery Saver (Sleep Mode) Battery Indication The Meter Structure Display Key

More information

KMD-S04 Multímetro de bolsillo

KMD-S04 Multímetro de bolsillo www.grupotemper.com KMD-S04 Multímetro de bolsillo Table of Contents Title Page Overview ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 3 Unpacking Inspection ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 4 Safety Information

More information

Accuracy 1.2 PERCENT AC VOLTAGE, 0.5 PERCENT DC VOLTAGE, 1.5 PERCENT DC CURRENT, 1 PERCENT RESISTANCE, 2.5 PERCENT TEMPERATURE Battery Type

Accuracy 1.2 PERCENT AC VOLTAGE, 0.5 PERCENT DC VOLTAGE, 1.5 PERCENT DC CURRENT, 1 PERCENT RESISTANCE, 2.5 PERCENT TEMPERATURE Battery Type 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 61603 Digital Multimeter Ideal Catalog Number 61603 Manufacturer Ideal Description Multimeter, Digital; Parameter Measured

More information

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual AM-510 Commercial / Residential Multimeter AM-510-EUR Digital Multimeter Users Manual AM-510 Commercial / Residential Multimeter AM-510-EUR Digital Multimeter English Users Manual Limited Warranty and

More information

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954 auto range, true rms ACA LEAKAGE TESTER Model : DL-9954 Your purchase of this ACA LEAKAGE TESTER marks a step forward for you into the field of precision measurement. Although this ACA LEAKAGE TESTER is

More information

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter DL6508 User's Guide 1500Amp True RMS AC/DC Clamp Meter Introduction Congratulations on your purchase of this DL6508 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage, Resistance,

More information

374/375/376 Clamp Meter. Users Manual

374/375/376 Clamp Meter. Users Manual 374/375/376 Clamp Meter Users Manual Introduction XWWarning Read "Safety Information" before you use the Meter. The Fluke 374, 375, and 376 (the Meter) measure true-rms ac current and voltage, dc current

More information

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

15B+/17B+/18B+ Calibration Manual. Digital Multimeter 5B+/7B+/8B+ Digital Multimeter Calibration Manual April 206 206 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective

More information

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC) User Manual Compact Autoranging Clamp Meters with NIST-Traceable Calibration Models 20250-55 (400 A AC), 20250-56 (400 A AC/DC) THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-55,-56 DS Clamp Meter

More information

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30 Handleiding / Manual INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Digital Clamp Multimeter from its packing, you should

More information