1 ZNR Transient/Surge Absorbers Type: E The ZNR Type E is capable of handling larger surge energy than Type D in applications to protect elec tron ic equipment or semi con duc tor devices from switch ing and induced light ning surg es. Features Very large surge withstanding capability with a compact size Direct mounting on boards like a power distribution board available Fast response to steep impulse voltage Low clamping voltage for better surge protection RoHS compliant Related Standards [UL/CSA recognized models are available on request] UL9 File No. E399 (Title: Surge Protective Devices) CSA C. No. Class File No. LR-9 (Title: Accessories and Parts for Electronic Products) Each type designation is not registered by Part Number. If you have any question on type designation, please contact and ask our offi ce. Recommended Applications Transistor, diode, IC, thyristor or triac semi con duc tor pro tec tion Surge protection in industrial power plant operations Relay or electromagnetic valve surge absorption Surge absorption applications in broadcasting, communications devices, traffic/railroad, agricultural facilities, waterworks Surge protection of automatic control devices for power distribution line Note: Ask our factory for Product Specifi cation before use. Handling Precautions and Minimum Quantity / Packing Unit Please see Related Information Explanation of Part Numbers Product Code Element Size Type Tolerance Nominal Design No. Varistor Dimensions in mm (not to scale) W H L ISO M ERZCEK ± ± 39± ERZC3EK ± 55± 5± L W.3 5 H ZNR Date code Aug.

2 Series Ratings and Characteristics (ERZCEK) Operating Temperature Range : to 5 C Storage Temperature Range : to C ERZCEK ERZCEK ERZCEK7 ERZCEK3 ERZCEK39 ERZCEK3 ERZCEK7 ERZCEK5 ERZCEK ERZCEK ERZCEK75 ERZCEK7 ERZCEK ERZCEK9 ERZCEK ERZCEK Varistor (5 to 5) ( to ) 7 (7 to 33) 3 (3 to 39) 39 (35 to 9) 3 (37 to 73) 7 (3 to 57) 5 (59 to 5) (55 to ) ( to 7) 75 (75 to 5) 7 (7 to 5) (73 to 9) 9 (9 to ) ( to ) (99 to ) Allowable Clamping Rated Power ( ms) (/ μs) time times Typical Capacitance (Reference) V ma (V) ACrms (V) DC (V) V A (V) (W) (J) (A) (A) at khz (pf) Series Ratings and Characteristics (ERZC3EK) Operating Temperature Range : to 5 C Storage Temperature Range : to C ERZC3EK ERZC3EK ERZC3EK7 ERZC3EK3 ERZC3EK39 ERZC3EK3 ERZC3EK7 ERZC3EK5 ERZC3EK ERZC3EK ERZC3EK75 ERZC3EK7 ERZC3EK ERZC3EK9 ERZC3EK ERZC3EK Varistor (5 to 5) ( to ) 7 (7 to 33) 3 (3 to 39) 39 (35 to 9) 3 (37 to 73) 7 (3 to 57) 5 (59 to 5) (55 to ) ( to 7) 75 (75 to 5) 7 (7 to 5) (73 to 9) 9 (9 to ) ( to ) (99 to ) Allowable Clamping Rated Power ( ms) (/ μs) time times Typical Capacitance (Reference) V ma (V) ACrms (V) DC (V) V A (V) (W) (J) (A) (A) at khz (pf) Aug.

3 Typical Characteristics (Type E) vs. Current (ERZCEK to ERZCEK5) (ERZCEK to ERZCEK) (V) (V) Impulse Derating Curve (Relation be tween impulse width and surge, repetitively) Series Series Series (ERZCEK to ERZCEK7) (ERZCEK3 to ERZCEK) (ERZCEK75 to ERZCEK) Impulse Impulse Impulse Aug.

4 Typical Characteristics (Type E) vs. Current (ERZC3EK to ERZC3EK5) (V) (ERZC3EK to ERZC3EK) (V) Impulse Derating Curve (Relation be tween impulse width and surge, repetitively) 3 Series 3 Series 3 Series (ERZC3EK to ERZC3EK7) (ERZC3EK3 to ERZC3EK) (ERZC3EK75 to ERZC3EK) Impulse Impulse Impulse 7 Aug.

5 Performance Characteristics (Type E) Characteristics Test Methods/Description Specifi cations Electrical Standard Test Condition Varistor Allowable Clamping Rated Power times time Electrical characteristics shall be measured at following conditions (Temperature: 5 to 35 C,Humidity: Max. 5 %) The voltage between two terminals with the specified measuring current CmA DC applied is called Vc or VCmA. The measurement shall be made as fast as possible to avoid heat affection. The maximum sinusoidal wave voltage (rms) or the maximum DC voltage that can be applied continuously. The maximum voltage between two terminals with the specified standard impulse current (/ μs). The maximum power that can be applied within the specified ambient temperature. The maximum energy within the varistor voltage change of ± % when one impulse of ms is applied. The maximum current within the varistor voltage change of ± % with the standard impulse cur rent (/ μs) applied two times with an interval of 5 minutes. The maximum current within the varistor voltage change of ± % with the standard impulse cur rent (/ μs) applied one time. To meet the specifi ed value. Mechanical Environmental Temperature Coeffi cient of Varistor Impulse Life Withstanding (Body Insulation) Robustness of Terminations (Tensile) Vibration Dry Heat/ High Temperature Storage Temperature Cycle Dry Heat Load/ High Temperature Load Damp Heat/Humidity (Steady State) VC at 7 C VC at C (%/ C) VC at C 5 The change of Vc shall be measured after the impulse listed below is applied times continuously with the interval of ten sec onds at room temperature. Series A (/ μs) 3 Series A (/ μs) The commercial frequency voltage of AC.5 kv shall be applied between terminals and the bottom of the unit for one minute. After gradually applying the load of 9 N (5 kgf) and keeping the unit fi xed for seconds in an axial direction, the terminal shall be visually examined for any. After repeadly applying a single harmonic vibration (amplitude:.75 mm): double amplitude:.5 mm with minute vibration frequency cycles ( Hz to 55 Hz to Hz) to each of three perpendicular directions for hours. Thereafter, the of the ter mi nals is visually examined. The specimen shall be subjected to ±3 C for hours in a thermostatic bath without load and then stored at room temperature and humidity for one to two hours. Thereafter, the change of Vc shall be measured. Step Temperature ( C) Period (minutes) Room Temp. 3 max Room Temp. 3 max. The temperature cycle shown below shall be repeated five times and then stored at room temperature and humidity for one to two hours. The change of Vc and mechanical shall be examined. After being continuously applied the Allowable at 5±5 C for hours, the specimen shall be stored at room temperature and humidity for one to two hours. Thereafter, the change of Vc shall be measured. The specimen shall be subjected to ± C, 9 to 95 %RH for hours without load and then stored at room temperature and hu mid i ty for one to two hours. Thereafter, the change of Vc shall be measured. to.5 %/ C max. ΔV ma/v ma < ± % ΔV ma/v ma < ±5 % ΔV ma/v ma < ±5 % ΔV ma/v ma < ± % ΔV ma/v ma < ±5 % Aug.

METAL OXIDE VARISTOR CHARACTERISTICS AND FUNCTION INTRODUCTION

METAL OXIDE VARISTOR CHARACTERISTICS AND FUNCTION INTRODUCTION CHARACTERISTICS AND FUNCTION INTRODUCTION JNR ZINC OXIDE VARISTORS Zinc oxide varistor is a voltage dependent resistor with symmetrical voltage-current characteristics that is designed to protect all kinds

More information

Metal Oxide Varistors

Metal Oxide Varistors Straight Lead Dimensions Table Series 5D 7D 10D 14D 20D D max 7 9.5 14 17.5 24 d* 0.6 0.6 0.8 0.8 1 W** 5 5 7.5 7.5 10 H max 12.5 14.5 20 22.5 29.5 H1 max 10 12 17 20.5 28 T max 4.9 4.9 8.5 8.5 9 P max

More information

Cut and formed product is available on select sizes; contact factory for details Flameproof coating per UL94 V-0 RoHS compliant / lead-free

Cut and formed product is available on select sizes; contact factory for details Flameproof coating per UL94 V-0 RoHS compliant / lead-free Features: Excellent anti-surge characteristics Stable characteristics through the resistance range Good alternative to carbon composition resistors Applications include power supplies, CRT s, and antisurge

More information

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation General Purpose Relays MKS Exceptionally Reliable General Purpose Relay now available with Lockable Test Button IEC Rating of A 0 V AC 0/0 Hz, General use 100,000 cycles. Mechanical indicator standard

More information

Chip Varistor LVS B DESCRIPTION APPLICATIONS FEATURES ORDERING INFORMATION. Capacitance 030 = 3pF 300 = 30pF 301 = 300pF

Chip Varistor LVS B DESCRIPTION APPLICATIONS FEATURES ORDERING INFORMATION. Capacitance 030 = 3pF 300 = 30pF 301 = 300pF DESCRIPTION The LVS series is metal oxide based chip varistor for transient voltage suppression. They have non-linear voltage-current behavior, similar to zener diode. Multilayer structured varistor, however,

More information

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E 1 New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator

More information

SRM VDE. REG.-Nr. E932. Cap Diameter (D1, mm) Body Diameter (D2, mm)

SRM VDE. REG.-Nr. E932. Cap Diameter (D1, mm) Body Diameter (D2, mm) D2 VDE REG.-Nr. E932 Specifications Per IEC 605- Features B L D IEC60065 & UL676 Compliant MELF packaging yet capable of high power handling Special conductive film enhances anti-surge capability. Absorbs

More information

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291 COMP SIZE HIGH PRECISI IMERS VARIOUS OUPU & OPERAI MODE YPES SDX (one) SDX imers Features UL File No.: E22222 CSA File No.: LR3929 3 operation modes added for fuller lineup Now, operation modes include

More information

1a 16A power relay for micro wave oven

1a 16A power relay for micro wave oven VDE 1a power relay for micro wave oven LE RELAYS (ALE) RoHS compliant FEATURES 1. Supports magnetron and heater loads. Capable for switching magnetron and heater loads found in microwave ovens. 2. Excellent

More information

Spark Gap (SPG) Data Sheet

Spark Gap (SPG) Data Sheet Spark Gap (SPG) ata Sheet Features Approximately zero leaking current before clamping voltage Less decay at on/off state. High capability to withstand repeated lightning strikes. Low electrode capacitance(

More information

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator

More information

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend PC Power Relay A Miniature Relay with -pole A/5A Switching Capability and 0 kv Impulse Withstand Voltage Highly efficient magnetic circuit for high sensitivity (200 mw). Small, yet provides 0-kV impulse

More information

HVR. Lead Wire Length (H, mm)

HVR. Lead Wire Length (H, mm) High Resistor Features Special conductive film withstands high voltage d L H D working voltage far over that of generalpurpose resistors Suitable for applications such as TV s, high voltage power supply,

More information

Continuous C-III Series Units. ) 2ms Rectangular Wave 40 to 530 J Operating Ambient Temperature Range (T A

Continuous C-III Series Units. ) 2ms Rectangular Wave 40 to 530 J Operating Ambient Temperature Range (T A RoHS Description The C-III Series of Metal-Oxide Varistors (MOVs) are specifically designed for applications requiring high surge energy absorption ratings and superior multiple pulse absorption rating.

More information

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

Glass Gas Discharge. RL501 Series. Circuit Protection System ELECTRONICS

Glass Gas Discharge. RL501 Series. Circuit Protection System ELECTRONICS ELECTRONICS Glass Gas Discharge RL501 Series Features Approximately zero leaking current before clamping voltage Less decay at on/off state. High capability to withstand repeated lightning strikes. Low

More information

Overcurrent Protection / 7SJ45

Overcurrent Protection / 7SJ45 Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers

More information

Applications. Capacitance Code (pf)

Applications. Capacitance Code (pf) AC Line EMI Suppression and RC Networks PMZ2035 Series Metallized Impregnated Paper, Class X1, 440 VAC/1,000 VDC Overview Applications The PMZ2035 Series is constructed of multilayer metallized paper encapsulated

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT PCB Relay A Power Relay with Various Models High-sensitivity ( mw) and High-capacity ( A) Models available. Low profile:.7 mm max. in height Conforms to VDE (EN0-), UL and CSA.. Meets EN0- requirements

More information

High-Q Capacitors (Microwave Chip Capacitors)

High-Q Capacitors (Microwave Chip Capacitors) High-Q Capacitors (Microwave Chip Capacitors) Series: ECD Features Low with tight tolerance (0. to 5.0 pf, +/ 0.05 pf to +/ 5 %) High Q value / Low ESR at High Frequencies Ultra-Stable C0G Performance

More information

Gas Discharge Tube (GDT) Data Sheet

Gas Discharge Tube (GDT) Data Sheet Gas Tube (GDT) Data Sheet Features Provide ultra-fast response to surge voltage from slow-rising surge of 100V/s to rapid-rising surge of 1KV/μs. Stable breakdown voltage. High insulation resistance. Low

More information

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS 20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from

More information

02/11/2015

02/11/2015 35 mm - 1 Relay 8A OUR3 Part number 88867103 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges NO: RL-159 PRODUCT: G3PA SSRs, G32A Cartridges DATE: January 2017 TYPE: Partial Discontinuation Notice Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X

More information

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2 Miniature Relay for Signal Circuits ROHS compliant. Wide switching power of 10 µa to 2 A. High dielectric strength coil-contacts:1,000 VAC; open contacts: 750 VAC. Conforms to FCC Part 68 requirements.

More information

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage ow-profile Relay with Various Models ow profile:.7 mm in height. Creepage distance 8mm between coil and contacts 0 kv Impulse withstand voltage Models with AC coil available. High-Inrush model available

More information

KP 376 KP/MMKP 376. AC and pulse metallized polypropylene film capacitors. Fig.1 Simplified outlines.

KP 376 KP/MMKP 376. AC and pulse metallized polypropylene film capacitors. Fig.1 Simplified outlines. KP AND KP/MMKP RADIAL POTTED CAPACITORS PITCH 15/22.5/27.5 mm P=15 mm P = 22.5 to 27.5 mm DR931960 Fig.1 Simplified outlines. FEATURES 15.0 to 27.5 mm lead pitch Supplied loose in box and taped on reel.

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Metal-Oxide Varistors (MOVs) Thermally Protected Varistors > SMOV 25S Varistor Series

Metal-Oxide Varistors (MOVs) Thermally Protected Varistors > SMOV 25S Varistor Series S25S Varistor Series RoHS Description The Littelfuse S 25S thermally protected varistor is a self-protected device. It consists of a 25mm square varistor with an integral thermal designed to open in the

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC

More information

Subject to changes 11/2003 Page 1/7

Subject to changes 11/2003 Page 1/7 Main Characteristics: Zero switching. LED display. Various connection systems. Plug-in control terminal. Degree of protection IP 2. Double-insulated design. General Data: Standards / Approvals DIN EN 697--3

More information

02/11/2015

02/11/2015 35 mm - 2 Relays 8A PL2R1 Part number 88867455 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

Interference Suppression Film Capacitor - Class X2 Axial MKT 253 V AC - Continuous Across the Line

Interference Suppression Film Capacitor - Class X2 Axial MKT 253 V AC - Continuous Across the Line Interference Suppression Film Capacitor - Class X2 Axial MKT 253 V AC - Continuous Across the Line FEATURES Axial mounting Low building height Material categorization: for definitions of compliance please

More information

1a/1c 5A/10A small power relays

1a/1c 5A/10A small power relays VDE a/c A/A small power relays RELAYS Compliance with RoHS Directive FEATURES High electrical noise immunity High switching capacity in a compact package High sensitivity: mw (a), mw (c) High surge voltage:,

More information

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation

More information

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S

More information

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay EN6033-1 GWT compliant Low profile: 1.7mm inch height 1a/1c 16A power relay LZ-N RELAYS (ALZN) Protective construction: Flux-resistant type New 12. 28.8.492 RoHS compliant 1.7 (Unit: mm inch) FEATURES

More information

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms Compact size and 3A power relays for energy management and industrial equipment HE-S RELAYS New TYPICAL APPLICATIONS Photovoltaic power generation systems (Solar inverter) Uninterruptible Power Supplies

More information

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS.81 The three-phase monitoring relay CM-PVS.81 monitors the phase parameters phase sequence, phase failure as well as over- and undervoltage. The device is

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

Gas Discharge Tube (GDT) Data Sheet

Gas Discharge Tube (GDT) Data Sheet Gas Discharge Tube (GDT) Data Sheet Features Provide ultra-fast response to surge voltage from slow-rising surge of 100V/s to rapid-rising surge of 1KV/μs. Stable breakdown voltage. High insulation resistance.

More information

DC/DC Converter B_XT-2WR2 Series

DC/DC Converter B_XT-2WR2 Series 2W, Fixed input voltage, isolated & unregulated single output Selection Guide Patent Protection RoHS FEATURES Operating temperature range: -4 to +15 High efficiency up to 84% Compact SMD package Isolation

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

16A POWER RELAY FOR MICRO WAVE OVEN

16A POWER RELAY FOR MICRO WAVE OVEN VDE 6A POWER RELAY FOR MICRO WAVE OVEN LE RELAYS (ALE) TMP type New FEATURES. Price competitive having better price competitiveness (New 4 mw only) 2. Supports magnetron and heater loads. Switching possible

More information

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching PCB Relay Subminiature, Sensitive SPDT Signal Switching Relay High sensitivity: 98-mW pickup coil power. Impulse withstand voltage meets FCC Part 68 requirements. Fully sealed construction. Unique moving

More information

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO New Product News G9EJ--E Compact Capable of Switching 4 V A DC loads Actualize a high capacity interruption through the function of extinction of magnetic arc by adopting high-efficiency magnetic circuit.

More information

15 W DC/DC CONVERTERS. SERIES DESCRIPTION Page. PC15WR 2:1 Input Range 2 2 x 1 Metal Can Package 2kv Isolation

15 W DC/DC CONVERTERS. SERIES DESCRIPTION Page. PC15WR 2:1 Input Range 2 2 x 1 Metal Can Package 2kv Isolation 15 W DC/DC CONVERTERS SERIES DESCRIPTION Page PC15WR 2:1 Input Range 2 2 x 1 Metal Can Package 2kv Isolation PC15WR4 4:1 Input Range 6 2 x 1 Metal Can Package 2kv Isolation CTC TECHNOLOGY CO.,LTD. DC /

More information

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC Product data sheet Characteristics RE11RMMU time delay relay 10 functions - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Width pitch dimension Control type Voltage range Connections

More information

Gas Discharge Tube (GDT) Data Sheet

Gas Discharge Tube (GDT) Data Sheet Gas Discharge Tube (GDT) Data Sheet Features Provide ultra-fast response to surge voltage from slow-rising surge of 100V/s to rapid-rising surge of 1KV/μs. Stable breakdown voltage. High insulation resistance.

More information

DATA SHEET MKP 435 X2

DATA SHEET MKP 435 X2 DATA SHEET Interference suppression film capacitors, NEW File under BCcomponents, BC05 2001 Jun 22 MKP RADIAL POTTED TYPE PITCH 15/22.5/27.5 mm 296x12(full_width) CBB112 Fig.1 Simplified outlines. FEATURES

More information

HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY

HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY VDE JQ HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY JQ RELAYS.77.39.. mm inch FEATURES High electrical noise immunity High switching capacity in a compact package High sensitivity: mw (a), mw () High

More information

AUTOMOTIVE RELAY WITH ISO TERMINAL ARRANGEMENT

AUTOMOTIVE RELAY WITH ISO TERMINAL ARRANGEMENT AUTOMOTIVE RELAY WITH ISO TERMINAL ARRANGEMENT CB RELAYS Compliance with RoHS Directive FEATURES 1. This relay has an ISO (International Organization for Standardization) terminal arrangement. Terminals

More information

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter Features Regulated Converters Description Compact low profile AC-DC power supply mw no load power consumption Class II power supply with kvac isolation Universal input voltage range (~VAC) Low output ripple/noise

More information

X Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters

X Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters Features RoHS lead-free-solder and lead-solder-exempted products are available Rugged 5 mm DIN-rail snap-fit design Class I equipment Universal AC-input with single stage conversion AC to DC or DC input

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks -A Load Compact: 20 x 15 x 10 mm (L x W x H). Low power consumption: 200 mw. Flux protection or plastic-sealed construction available.

More information

Applications. Capacitance Code (pf) First two digits represent significant figures. Third digit specifies number of zeros.

Applications. Capacitance Code (pf) First two digits represent significant figures. Third digit specifies number of zeros. AC Line EMI Suppression and RC Networks P409 Series, Integrated Resistor, Metallized Impregnated Paper, Class X2, 275 VAC Overview Applications The P409 Series is constructed of multilayer metallized paper

More information

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact Data sheet Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact The CT-MVS.12 is a multifunctional electronic timer from the CT-S range and provides 10 timing functions and 10 time ranges.

More information

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay Overcurrent Protection / 7SJ46 SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay Function overview Fig. /11 Description The SIPROTEC easy 7SJ46 is a numerical overcurrent protection relay which

More information

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation

More information

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal SPST Slim Power Relay for A switching Slim -mm width and miniature size. (20.08 12. mm) High switching capability A (20 VAC and VDC), and high contact reliability by crossbar-twin contact. Low power consumption

More information

H L G -150H s er i es

H L G -150H s er i es F 110 M M SELV Features : Universal AC input / Full range (up to 305VAC) Built-in active PFC function High efficiency up to 94% Protections: Short circuit / Over current / Over voltage / Over temperature

More information

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Features. Designation (provided with) style. Contact. Insulation. system. gap. 110A-1AH-F-C 110BA-1AH-F-C 110A-1AH1-F-C 110BA-1AH1-F-C High power type

Features. Designation (provided with) style. Contact. Insulation. system. gap. 110A-1AH-F-C 110BA-1AH-F-C 110A-1AH1-F-C 110BA-1AH1-F-C High power type 0 eatures High duty sugar cube relay with 6A 77VAC, A 77VAC. Contact gap can be greater than.mm,.mm. Conforms to European photovoltaic standard IEC 609-. Coil holding can be reduced to 6%, %V of the nominal

More information

15,000 Watt Transient Voltage Suppressor (TVS) Protection Device

15,000 Watt Transient Voltage Suppressor (TVS) Protection Device Compliant 15,000 Watt Transient Voltage Suppressor (TVS) Protection Device DESCRIPTION This device clamps dangerous high-voltage short-term transients such as those produced by the secondary effects of

More information

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-

More information

Carbon Composition Resistor

Carbon Composition Resistor Rating and Dimensions Dimensions : Millimetres Power Dimensions L D Lead d Maximum Rated Maximum Overload Dielectric Withstand Tolerance ±(%) R-Value 1/4 W 6.4 ±0.7 2.3 ±0.2 0.6 250 400 500 5 E-24 1/2

More information

08/07/2015

08/07/2015 17.5 mm - 1 Solid State Relay 0.7A MUS2 Part number 88827004 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external

More information

Features. Symbol Parameters Test Conditions Min Max Unit V T. TA=25 C Pulse Wave = 10μs, Sine Wave, f=120hz K2201GL 230 V BO K2401GL K2401GL

Features. Symbol Parameters Test Conditions Min Max Unit V T. TA=25 C Pulse Wave = 10μs, Sine Wave, f=120hz K2201GL 230 V BO K2401GL K2401GL Standard Bidirectional SIDACs Kxxx1GL Series RoHS Description Schematic Symbol The Multipulse SIDAC is a voltage switch used in Metal- Halide lamp ignition circuits, as well as High Pressure Sodium lamp

More information

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q PCB Relay G5Q Compact, High Isolation Relay D Compact single pole relay with high isolation between coil and contacts. D Up to 10 A switching on the NO contacts. D Ensures a withstand impulse voltage of

More information

AC and Pulse Metallized Polypropylene Film Capacitors MKP and MKP/MKP Radial Potted Type. LEADS Tinned wire

AC and Pulse Metallized Polypropylene Film Capacitors MKP and MKP/MKP Radial Potted Type. LEADS Tinned wire AC and Pulse Metallized Polypropylene Film Capacitors MKP and MKP/MKP Radial Potted Type CBB817 Dimensions in mm APPLICATIONS Where steep pulses occur e.g. SMPS (switch mode power supplies). Motor control

More information

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure Compact Power Relays MK CSM_MK_DS_E A Wide Variation of Octal Pin Power Relays Encased Relays unified to an AC rating (/ VAC at /Hz and / VAC at / Hz). Easy to install, wire, and use. Highly durable with

More information

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES High Carrying Current Type Miniature Low Profile Automotive Relay CP RELAYS POWER TYPE Sealed 13.1 14.1 9..374 FEATURES Maximum carrying current of 3 A (4 mw type, 1 V applied)

More information

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts The CT-WBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions

More information

Features : IP65 IP67 SELV

Features : IP65 IP67 SELV F 110 SELV Features : H LG-24 0 H se ri es Universal AC input / Full range (up to 305VAC) Built-in active PFC function Protections: Short circuit / Over current / Over voltage / Over temperature Cooling

More information

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4 58 58 3 & 4 CO relay interface modules, 31 mm wide with Push-in terminals Ideal interface for PLC and electronic systems 58.P3 58.P4 Type 58.P3 3 CO 10 A Push-in terminals Type 58.P4 4 CO 7 A Push-in terminals

More information

Polypropylene Pulse/High Frequency Capacitors R79 Series Single Metallized Polypropylene Film, Radial, 5 mm Lead Spacing, Multipurpose Applications

Polypropylene Pulse/High Frequency Capacitors R79 Series Single Metallized Polypropylene Film, Radial, 5 mm Lead Spacing, Multipurpose Applications Polypropylene Pulse/High Frequency Capacitors R79 Series Single Metallized Polypropylene Film, Radial, 5 mm Lead Spacing, Multipurpose Applications Overview The R79 Series is constructed of metallized

More information

RE17LLBM asymmetrical flashing relay s V AC - solid state output

RE17LLBM asymmetrical flashing relay s V AC - solid state output Characteristics asymmetrical flashing relay - 0.1..1 s - 24..240 V AC - solid state output Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 75.00 USD Main Range

More information

SAMSUNG ELECTRO-MECHANICS CO., LTD

SAMSUNG ELECTRO-MECHANICS CO., LTD Model Name : Features : ㅡ Suitable for LED lighting application ㅡ UL8750, UL1310 Class 2 ㅡ For use in Dry and Damp Location ㅡ Full-protection provided: OCP/OVP/OTP/SCP ㅡ 0-10V Dimming Control ㅡ IP67 ㅡ

More information

COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS

COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS HK RELAYS (AHK) RoHS Directive compatibility information http://www.nais-e.com/ FEATURES Compact and high-capacity Form C: A, Form C: high capacity

More information

Compliant with European standards 1a/1c 6A Slim power relays

Compliant with European standards 1a/1c 6A Slim power relays PF (APF) VDE Compliant with European standards 1a/1c 6A Slim power relays PF RELAYS (APF) RoHS compliant FEATURES 1. High density mounting with mm.197 inch width Space saved with mm.197 inch slim type

More information

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable

More information

4 PIN DIP PHOTOTRANSISTOR PHOTOCOUPLER AC INPUT PHOTOCOUPLER EL814 Series

4 PIN DIP PHOTOTRANSISTOR PHOTOCOUPLER AC INPUT PHOTOCOUPLER EL814 Series Schematic Features: AC input response Current transfer ratio (CTR: Min. 20% at I F =±1mA,V CE =5V) High isolation voltage between input and output (Viso=5000 V rms ) Wide Operating temperature range -55~110ºC

More information

4 PIN SOP PHOTOTRANSISTOR PHOTOCOUPLER. EL357 Series. Features: Description. Applications

4 PIN SOP PHOTOTRANSISTOR PHOTOCOUPLER. EL357 Series. Features: Description. Applications Features: Current transfer ratio (CTR: 50~600% at I F =5mA, V CE =5V) High isolation voltage between input and output (Viso=3750 V rms ) Compact small outline package Pb free and RoHS compliant. UL approved

More information

HVG-65 SERIES 65 Watt LED Power Supply Measures: 7.44 x 4.42 x 1.45

HVG-65 SERIES 65 Watt LED Power Supply Measures: 7.44 x 4.42 x 1.45 IP65 IP67 Mean Well SPECIFICATION MODEL DC VOLTAGE HVG-65-12 12V HVG-65-15 15V HVG-65- V HVG-65-24 24V HVG-65-30 30V HVG-65-36 36V HVG-65-42 42V HVG-65-48 48V HVG-65-54 54V CONSTANT CURRENT REGION Note.4

More information

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage TESTING ULTRA LOW PROFILE POLARIZED RELAY RELAYS 9...7 mm inch FEATURES Low profile mm.7 inch height High contact capacity: Surge withstand between contact and coil:, V (Telcordia) RoHS Directive compatibility

More information

Load for air conditioner 1a 20A power relays

Load for air conditioner 1a 20A power relays VDE Load for air conditioner 1a A power relays LF RELAYS (ALF) TMP type PCB type RoHS compliant FEATURES 1. Ideal for compressor and inverter loads 1) Compressor load: A 5V AC ) Inverter load: A V AC,

More information

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter Features Regulated Converters 5W Class II Power Supply in Compact 1 x 1 Package (High Power Density) Internal EMC Class B Filter UL/IEC/EN695-1 certified UL/IEC/EN62368-1 certified Electrical Protection

More information

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE RELAYS (60A type only) A PC board type A TM type 60A Screw terminal type 80A Connector type 300A Connector type Compliance with RoHS Directive

More information

G8P. PCB Power Relay. Model Number Legend. Application Examples. Ordering Information

G8P. PCB Power Relay. Model Number Legend. Application Examples. Ordering Information CB ower Relay Up to 30 A switching capacity in compact package. 2.0 mm cantact gap type available (-1A4-B) Available with quick-connect contact terminals for easy load connecting with either QC or CB coil

More information

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550 UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY K-RELAYS.0 a UL File No.: E3 CSA File No.: LR2550.0.8 00 times more reliable than similar designs Extra long life Mechanical: more than 0 8 operations Electrical

More information

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE (60A type only) RELAYS A PC board type 80A Connector type 60A Screw terminal type A TM type 300A Connector type RoHS Directive compatibility

More information

48 Series - Relay interface modules A. Features

48 Series - Relay interface modules A. Features Series - Relay interface modules 8-0 - 6 A Features & Pole relay interface modules, 5.8 mm wide. Ideal interface for PLC and electronic systems.3 - Pole 0 A.5 - Pole 8 A.6 - Pole 6 A coils or sensitive

More information

MI2000ERW. Series. Miniature 1 x 1 20W, Ultra-Wide 2:1 Input DC/DC Con vert ers. Key Features:

MI2000ERW. Series. Miniature 1 x 1 20W, Ultra-Wide 2:1 Input DC/DC Con vert ers.   Key Features: MI2000ERW Miniature 1 x 1 20W, Ultra-Wide 2:1 Input DC/DC Con vert ers Key Features: 20W Output Power 2:1 Input Voltage Range Miniature 1 x 1 Case 1,500 VDC Isolation Meets CISPR 32/EN 55032 High Efficiency

More information

1a/1c/2a/2c/5A/10A power relays for power supply

1a/1c/2a/2c/5A/10A power relays for power supply Automation Controls Catalog VDE a/c/2a/2c/a/a power relays for power supply JW RELAYS RoHS compliant Protective construction: Flux-resistant /Sealed ORDERING INFORMATION Contact arrangement : Form C a:

More information

DATA SHEET. KP 460 to 464 Polypropylene film foil capacitors. BCcomponents

DATA SHEET. KP 460 to 464 Polypropylene film foil capacitors. BCcomponents DATA SHEET KP 460 to 464 Polypropylene film foil capacitors Supersedes data of 2001 Sep 13 File under BCcomponents, BC05 2002 Oct 09 KP AXIAL EPOXY LACQUERED TYPE 296x12(full_width) CBA369 Fig.1 Simplified

More information