Getting Started Guide v1.1

Size: px
Start display at page:

Download "Getting Started Guide v1.1"

Transcription

1 Activate your WeatherTRAK Pro3 Pre-activate to expedite at or call (800) Getting Started Guide v1.1 Included in documentation pack: Getting Started Guide Warranty Installation Instructions Quick Start Programming Guide Flow Reference Guide Troubleshooting Site Profile Worksheets Quick Reference Guide

2 WeatherTRAK ET Pro3 Warranty Our Promise to You WeatherTRAK Product Series Warranty HydroPoint Data Systems Inc. warrants to the purchaser of its WeatherTRAK products, when shipped in its original carton that they will be free from defects in materials and workmanship for the time period set forth below. During the warranty period, HydroPoint Data Systems, Inc. will, at its option, either repair the defect or replace the defective product or part thereof at no charge to the purchaser for parts during the warranty period. The WeatherTRAK ET Pro3 series has a five (5) year warranty from date of purchase. This warranty does not apply to any product which has been damaged, defaced, subjected to misuse, abnormal service or handling (including shipping damage), or which has been altered in design or construction. This warranty does not cover surface discoloration on stainless steel enclosures. Surface discoloration can occur from a variety of environmental conditions outside of HydroPoint s control such as windblown soils, water quality, and contaminants. The warranty described above is in addition to whatever implied warranty may be granted to purchaser by law. (All implied warranties, including the warranty of mechantability and fit for use, are limited to the period(s) from date of purchase set forth above). Neither sales personnel of the seller nor any other person is authorized to make any warranties other than those described above, or to extend the duration of any warranties beyond the time period described herein. The warranty described above shall be the sole and exclusive warranty granted by HydroPoint Data Systems, Inc. and shall be the sole and exclusive remedy available to the purchaser. Correction of defects, in the manner and period of time described herein, shall constitute complete fulfillment of all liabilities and responsibilities of HydroPoint Data Systems, Inc. to the purchaser with respect to the product, and shall constitute full satisfaction of all claims, whether based on contract, negligence, strictly liability or otherwise. Warranty Service Procedures In order to enforce the rights under this limited warranty, the purchaser must notify HydroPoint Data Systems, Inc., of a warranty claim by contacting (800) At that time, the purchaser will be asked to provide dated proof of original purchase. Acceptable forms of this shall be a photo copy or scanned image of the dated original invoice faxed or ed to HydroPoint Data Systems, Inc. The purchaser will also need to provide a full description of the type of problem occurring, a contact name, address and telephone number and/ or . If requested, purchaser must return the defective product at their own expense. Table of Contents Warranty... 2 Installation Instructions... 3 Getting to know WeatherTRAK... 4 Wall Installation... 6 Activation Programming Quick Start Programming Guide Activation or Help Programming Maintenance Tips Flow Reference Guide Function Setup Learning Station Flow Troubleshooting Guide WeatherTRAK ET Pro3 Central Alerts Definition of Alerts In no event shall HydroPoint Data Systems, Inc., be liable or in any way responsible, for any damages or defects in the product which were caused by repairs or attempted repairs performed by anyone other than HydroPoint Data Systems, Inc. Nor shall HydroPoint Data Systems, Inc., be liable or in any way responsible for any incidental or consequential economic or property damage. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. This warranty does not apply to improper installation or grounding, acts of God, such as lightning strikes and/or electrical line power surges, floods, earthquakes, hurricanes, tornados, vandalism, vermin such as slugs, ants, rodents etc., or improper electrical connections. HydroPoint Data Systems, Inc Corporate Circle Tel (800) Petaluma, CA Fax (707) support@hydropoint.com hydropoint.com 2013 HydroPoint Data Systems, Inc. All rights reserved. WTETP3W hydropoint.com

3 WeatherTRAK ET Pro3 Installation Instructions WeatherTRAK ET Pro3 Installation Instructions hydropoint.com

4 WeatherTRAK ET Pro3 Installation Instructions Getting to Know WeatherTRAK ET Pro3 In this section, controller navigation and new hardware features are identified. Navigation The user interface incorporates five main functions: 1. The display 2. The menu buttons 3. The left v and right l arrow buttons 4. The plus g and minus buttons 5. The * button Figure 1 Controller Front Panel The controller uses a 5-line, 24-character display. The screen contrast can be adjusted in the SETUP menu for low and bright light conditions. The upper line displays the sub-functions of any one of the 4 main menu buttons as shown in Figure 1. The second or lower line commonly displays choices of values within each sub-function. The third line is commonly used to display alerts or identify abbreviations of Alerts. Pushing the left or right arrow buttons allows you to scroll through all of the sub-functions within a menu. Pushing the plus and minus buttons allows you to select choices for each sub-function. Pressing and holding the * button in some limited sub-menus within the SETUP, STATIONS, FLOW and MANUAL menus will display additional information. In the COPY menu the * button executes the copy function. Controller Hardware The WeatherTRAK ET Pro3 series delivers unique hardware features to simplify installation, field diagnostics and troubleshooting: Interchangeable transformer and ground lug location Easily removable command module without the need for hand tools. Modular Station hardware keys to increase or decrease station count. Station Output Design The numerical values correspond to the Figure 2 line drawing of the station output boards for faster recognition. 1. Heavy-duty push-in type terminal blocks; two inputs per station require no tools to connect or disconnect field wire. (This makes it easier to test station output voltage or resistance to troubleshoot wiring issues). Terminal blocks are on one horizontal plane for faster installation with multiple valve common wire terminations. A pump start can be assigned as any station output. 2. Dedicated flow sensor inputs and separate master valve output. 3. Corresponding station output green LED s for confirmation of valve operation during scheduled irrigation, manual operation or valve field wire integrity testing. A blue LED designates a master valve output when programmed. 4. Removable rain sensor and 24-VAC terminal block for faster field wire connection. 5. Station modularity that provides 6-station count flexibility by simply inserting a hardware key to activate additional stations. Additional keys can be purchased from HydroPoint or your local HydroPoint distributor. 6. Replaceable 3.0 amp slo-blow fuse protection to protect the transformer from field wire shorts. 7. Troubleshooting yellow and green LED s on the station input / output boards indicate 24- and 5-Volt power respectively confirming proper voltage has reached one or both station output boards. 8. Direct remote compatibility with either a Rain Master Pro Max UA with EX32 cable assembly or TRC Commander or Sidekick series hand-held remotes Note: Small mechanical footprint makes it easy to install and provides a wide range of applications particularly where space is limited HydroPoint Data Systems, Inc. All rights reserved. WTETP3II hydropoint.com

5 WeatherTRAK ET Pro3 Installation Instructions $ ^ & % Center Drill Points for Rain Sensor Mounting The bottom left and right outer sides of the enclosure have two sets of drilling center points. These drilling points are for enclosure mounting for specific Irritrol or Toro wireless or wired rain or rain/ freeze sensors. Two (2-qty) self-tapping stainless steel screws are taped to the inside of the enclosure to mount a rain sensor receiver when needed FL1 VC MV1 VC * FL2 VC MV1 VC Figure 2 Station Output Board Design Figure 4 Drill Points for Rain Switch Mounting Note: Station output boards and are identical, but do not support two rain sensors. Terminate the flow sensor and rain sensor wires in the station output board only. Note: Mount the rain sensor receiver on the opposite side of the transformer location to avoid reception issues for wireless models. Interchangeable Transformer The WeatherTRAK ET Pro3 ships with the transformer on the right side of the enclosure. This enclosure design allows the transformer to be moved to the left side to accommodate electrical connections as needed. The mounting bracket is interchangeable to simplify relocating the transformer to the left side when necessary. Removable Command Module The faceplate or command module can be easily removed or slid down into a lower position by loosening the captive screws by hand. Removing the command module provides access to the rain switch input and 24-VAC source. Note: If panel removal is necessary, support it with one hand, then disconnect the cables with the other hand and set it aside carefully. Figure 3 Interchangeable Transformer and Ground Lug Note: If the transformer is re-located to the left side, then relocate the ground lug to the right side as shown in Figure 3. Figure 5 Removable Command Module 2013 HydroPoint Data Systems, Inc. All rights reserved. WTETP3II hydropoint.com

6 WeatherTRAK ET Pro3 Installation Instructions Station Keys The WeatherTRAK ET Pro3 incorporates station count modularity by using station keys. The station input/output boards are available in two configurations, up to either 12 to 24 stations or 12 to 48 stations. To increase the station count from 12 to 18 stations or higher, insert a station key into the station output board from left to right (see Figure 6). The station key will illuminate when activated. The controller will automatically discover the expanded station count within 30 seconds. Wall Installation Note: Avoid potential electric shock by confirming the AC power is off before starting this work. Wall Mounting Instructions Locate the 2 mounting holes on the back of the enclosure. The two upper mounting holes are keyholes. This design allows the two upper fasteners to be installed first. The enclosure is then slipped over and pushed down to complete the installation (see Figure 7). Use the enclosed blue-colored paper template to locate these holes accurately. Typical mounting height for a wall-mount enclosure is between 41 and 48 above a finished surface. Figure 7 Example of Wall Mount Drilling Template Figure 6 Station Keys To program additional stations: Increase Max Active Stations in the SETUP menu. Additional stations can be programmed from the controller or remotely via To increase the overall number of stations above 24, add an additional station expansion board with the corresponding station keys. Contact HydroPoint or your local distributor for this service kit. Controller Electrical Specifications Transformer Size: 3.0 amp, 80 VA, UL listed Input Power: 120 VAC (60 Hz) or 220 VAC (60Hz) Station Output Specifications: 24 VAC (60 Hz) 1.0 amps (1000 milliamps) max. per station output / pump output 1.0 amps (1.0 milliamps) max master valve output 3.0 amps maximum allowable load A third mounting hole can be found in the center of the enclosure below the station input/output board. Before drilling, verify that the controller is level and vertically straight before installing. Step 1. Step 2. Step 3. Step 4. Remove the outer door to gain better access to the interior of the enclosure by sliding it upwards, then place it in a location to prevent damage. Mark and drill new mounting holes using the blue-colored paper template, then drill appropriately sized holes with a hammer-drill as needed. Use plastic inserts and mounting screws (taped to the controller with the enclosure keys) to secure the controller. Hang the enclosure on these fasteners and verify the enclosure is mounted level both vertically and horizontally. Locate the third center mounting hole and insert the last fastener. Tighten all fasteners to the enclosure to secure to the vertical surface HydroPoint Data Systems, Inc. All rights reserved. WTETP3II hydropoint.com

7 WeatherTRAK ET Pro3 Installation Instructions Connecting the Controller to AC Power The following wiring diagrams and instructions indicate AC power connections to both wall-mount and pedestal style controllers. The WeatherTRAK ET Pro3 series controller incorporates a dual voltage power supply for a wide range of commercial applications. The controller can be connected to a single phase 120V or single phase 220V source. The input side of the transformer has 5 color-coded conductors. A label is attached to the transformer body with identification for each conductor. Two of the conductors (specific to 220V connections) have been terminated with wire nuts, shortened and tied together with a zip-tie to avoid confusion for 120V installations. Note: Before making a connection to your WeatherTRAK ET Pro3 series controller, disconnect the power to avoid electric shock. This installation should be made by a qualified electrician and should meet state and local electrical codes. Step 1. Step 2. Step 3. Step 4. Step 5. Step 6. Confirm the controller has been securely fastened to a flat, vertical surface before starting this work. Open the enclosure door and locate the transformer mounted to the chassis. Thread an approved weatherproof plastic or galvanized metal junction box onto the 1/2 nipple and secure with a conduit locknut. Connect approved conduit to the underside of the junction box. Pull the required number of conductors and terminate them in the junction box with sufficient length so that wire nut connections can be made. Remove approximately 1/2 of the wire insulation of the conductor and use an appropriately sized wire nut based on the number of wire connections being made. Adhere to local and state electrical codes. The ground wire should be terminated with an appropriately sized eyelet (included on grounding stud) and secured with a nut with the integral star washer located within the junction box (see Figure 8). Figure 8 Typical 120 Volt Wiring Diagram Note: Blue and brown wires are tied off with a zip tie and wire nuts. Note: For 120 V wire applications, connect the following conductors from the primary side of the transformer to wiring from an approved electrical source (see Figure 8). The unused blue and brown wires are cut short and terminated with a wire nut. Note: For 220 V, single-phase applications connect the following conductors from the primary side of the transformer to wiring from an approved electrical source (see Figure 9) HydroPoint Data Systems, Inc. All rights reserved. WTETP3II hydropoint.com!

8 WeatherTRAK ET Pro3 Installation Instructions Note: When a wireless rain switch is used with a metal enclosure, install the rain sensor receiver outside the enclosure to ensure reception from a remotely mounted rain switch transmitter. Irritrol Wireless Rain Switch Installation Step 1: Mount the rain switch receiver where it can be easily accessed and observed. Note: Do not install a wireless rain sensor within metal enclosures where signal strength is diminished. Figure 9 Typical 220 Volt Wiring Diagram Step 2: Step 3: For wall-mount installations, route the receiver wires through the bottom of the enclosure into the interior of the enclosure. Deburr any field drilled through holes and insert a ¼ inside diameter rubber grommet to protect field wiring. Add a small amount of silicone sealant where the sensor wire enters the grommet for added protection. Avoid shorting wires from an open thru-hole without a grommet. A shorted wire can cause permanent damage to the controller electronics, an issue not covered under warranty. Locate the rain sensor input terminal block in the upper-left corner of the 24-station input/output board. This terminal block is designed to be removable to facilitate faster connection of rain sensor wiring. To remove, simply wiggle the terminal block side to side. Remove the rain switch wire jumper before installing the rain sensor wire. (See Figure 10). Note: Secure each ground wire with its own individual locking nut and integral star washer. The unused black and brown wires should be terminated with a wire nut separately. Rain Switch Installation The WeatherTRAK ET Pro3 series controller is compatible with the following manufacturers of normally closed wired or wireless rain or rain/freeze switches: Toro TM wired and wireless rain switches Irritrol TM wired and wireless rain switches Hunter Mini-Clik TM Hunter wireless Rain-Clik TM rain switches Rain Bird WR2 wireless rain switches The ET Pro3 series is not compatible with the following rain switches: Rain Bird Rain Check TM series Rain Bird Tipping Bucket TM models Rain Master Tipping Bucket TM models Water Conservation Services Rain Guard TM series Step 4: Step 5: Figure 10 Rain Switch Terminal Block with Loop Remove approximately 3/8 of wire insulation to expose the solid or stranded conductor. Confirm the lever of the screwless terminal is in the up or unlocked position. Insert the exposed wire and press the lever downward to lock. Confirm contact by gently pulling down on the inserted wire.! 2013 HydroPoint Data Systems, Inc. All rights reserved. WTETP3II hydropoint.com

9 WeatherTRAK ET Pro3 Installation Instructions Step 6: Step 7: Connect the red wires to the 24-VAC terminals to red colored terminals. These terminals are not polarized; either wire can be inserted into either of the two far left terminal positions. Insert the white wire into the white terminal and the brown colored wire into black terminal as shown in Figure 11. Note: Confirm the lever has not clamped down on the wire insulation which can result in electrical continuity and operation of the rain switch. Connecting a Flow Sensor The WeatherTRAK ET Pro3 series is compatible with Data Industrial (Badger Meter) IR 220 series, Creative Sensor Technology and Netafim (using reed switch registers) irrigation flow sensors. To connect a flow meter: Step 1: Locate the six-position terminal block in the middle of the first 12-station output board and locate two inputs for flow sensing on the far right. These are labeled FL1 / VC and reflect the color of the recommended shielded flow sensor wire (see Figure 12). 24 Rain Rain Flow 24 Input Input Sensor VAC RS1 RS2 Step 8: Step 9: Figure 11 Irritrol Wireless Rain Switch Series Locate the rain switch transmitter within the manufacturer s recommended range. Locate the transmitter where it will receive rainfall without obstruction. Confirm communication to the receiver before mounting permanently. Test the rain sensor function by pressing the test switch on top of the transmitter for a brief period of time. Confirm the controller displays RainSwitch in the RUN menu when the test switch is depressed. Note: For other compatible rain switch wiring diagrams, please read the manufacturer s installation instructions for normally closed rain switches. Step 2: Step 3: Step 4: Figure 12 Flow Sensor Input Remove 3/8 of wire insulation and place into the appropriate terminal block by connecting the red wire to FL1 (or the + terminal) and black wire to VC (or the - terminal). Close or push down the terminal block lever. Consult the Flow Reference Guide in this packet for instructions on how to setup flow. Connecting a Hand-Held Remote WeatherTRAK ET Pro3 series controllers come standard with handheld remote capability. Compatibility is simply plug and play with no additional wiring, software, activation or programming required. The WeatherTRAK ET Pro3 series is directly compatible with the following hand-held remotes: RainMaster TM PROMAX-UA with 32 EX extension cable (sold separately) TRC TM - TR Commander or Sidekick Series (sold separately) Note: These products are available through local distributors and are not part of the WeatherTRAK product line. Both hand-held remote products are intended for portable use and require that the transceiver with antenna be located outside the enclosure to ensure consistent operation. The station LED s will slightly illuminate when the hand-held receiver is plugged in. A blue LED will illuminate when a master valve is activated from the remote indicating it has been activated HydroPoint Data Systems, Inc. All rights reserved. WTETP3II hydropoint.com

10 WeatherTRAK ET Pro3 Installation Instructions Note: If permanent mounting of the transceiver is required, install the antenna outside the enclosure. Both the RainMaster and TRC remote cables can be plugged into either one of the vertically oriented 32-pin connectors on either station output board, (see Figure 13). The connectors correspond to stations 1-24 or stations as needed. Note: For stations 25-48, you must enter station 1 for 25, 2 for 26, 24 for 48 using the remote interface. Manual Valve Test To ensure all field wiring is properly connected and all stations are operating properly conduct a field wire integrity test. Step 1. Step 2. Step 3. Press the main menu button to MANUAL. Press the minus button until the Valve Test screen appears. Press the right arrow button until the following screen appears: RUN VALVE TEST RTVT:OFF 00 SH 00 NC Faults Step 4. Step 5. Press the SELECT button, then press the * button to start the test. It will take about 15 seconds to verify continuity to all stations and the master valve. If any field wiring issues exist, they will be identified as a Fault. A valve fault could be SH (Valve Short) from a failing solenoid OC (over current) from valves drawing more than 1000 ma or an NC (Valve No-Connect or open) reflecting a broken wire or wire that is not making good contact in the corresponding station terminal. Activation Figure 13 Hand-held Remote Connectors Note: Hand-held remote kits can be purchased through your local irrigation distributor. Note: Functionality of either remote is limited to manual on/off, station up or down and master valve on/off. Follow the hand-held remote manufacturer s programming sequence when a normally open master valve is in use. Another alternative is to use the Maintenance Timeout feature found in the ADVANCED menu to open the master valve in ½ hour increments from ½ hour to 8 hours. In order to receive daily weather updates, your controller must be activated. To activate, call HydroPoint Customer Service at (800) For a faster call, complete the blue activation card inside the controller before calling HydroPoint Customer Service. Programming Refer to the laminated Quick Start Programming Guide for programming instructions in both English and Spanish. Free online training is available at: Visit hydropoint.com or support@hydropoint.com to access and print additional copies of this Installation Guide. Note: RainMaster TM is a registered trademark of RainMaster Irrigation; PROMAX TM is registered product of RainMaster Irrigation; TRC TM is a registered trademark of Remote Control Technologies HydroPoint Data Systems, Inc. All rights reserved. WTETP3II hydropoint.com

11 Cloud Update Key Instructions HydroPoint is proud to produce world-class irrigation control products. We are constantly adding new features and improving existing products. Firmware upgrades are always free, as long as your hardware is compatible. The Cloud Update Key is a USB device that you plug into a USB port on the back side of the controller s command module. The key enables the controller to receive firmware updates to occur from the cloud on an as-needed basis. The Cloud Update Key is for use on one controller, and must remain installed to maintain functionality. To get started, follow the instructions below. Installing the Key Locate the USB port on the back side of the command module. Insert the Cloud Update Key as pictured below. Close the command module door. Restarting the Controller After you plug in the key, you need to restart the controller in order to have it recognize the key. Press the Help button. Press the button until the Restart Controller screen displays. Press the * button to restart the controller. The controller will beep, and the screen will go black and then it will restart. This should take about 15 seconds. To verify the update, look for the Update Key Installed message in the bottom corner of the display. Affix the Cloud Updates enabled sticker on the lower right side of the command module. Note: If the Update Key Installed message does not appear or other issues are encountered, call customer support at

12 WeatherTRAK ET Pro3 Quick Start Programming Guide WeatherTRAK ET Pro3 Quick Start Programming Guide hydropoint.com

13 WeatherTRAK ET Pro3 Quick Start Programming Guide Date: Year, Month, Day Time: Hour (confirm am or pm), minutes Time Zone: Select your local time zone Auto Daylight Savings: Automatically updates controller twice a year, unless you press the button to No. Maximum Active Stations: Number of stations physically wired into the controller. Stack or Overlap: When Stack is selected, all programs operate one after another. The start time and water window for all programs is assigned to Program A. When Overlap is selected, each program can have its own start time and water window. See the Owners Manual for more detail. Activation or Help Call Customer Service The controller must be activated to receive daily ET information (local weather information). To speed up activation, complete the Activation card included with the manuals and other documentation before calling Customer Service. CONTROLLER MUST BE ACTIVATED to use AUTOMATED BY WEATHERTRAK or USER WITH ET. Programming Setup The following SETUP functions are optional: Master Valve: Select the type of Master Valve if used. Note: It is important to select None if a master valve does not exist. Selecting Normally Open or Normally Closed when you do not have a master valve may cause a Valve alert that can prevent irrigation. Assign Pump Start Output: Any station output may be selected. If a pump start is not required, leave this setting as Not Assigned. Runtime Valve Test: Default setting is Yes. See the Owner s Manual for more details. Max Backup ET: Represents the worst-case weekly ET for your area for the month of July. If you are not sure what this number should be, call our Customer Service 800 number for help. Days / Times In this menu a start time, water window and a water day mode can be assigned to one of four available programs A-D. If a pump start has been assigned as a station output, any one of three programs can be excluded from a pump start. Note: Check for STACK or OVERLAP (See SETUP for Stack or Overlap.): If Stack is set; programs B, C and D will have the same start time as program A. Programs will run sequentially starting with program A. If Overlap is set, different start times may be set for each program. The following SETUP functions must be setup for the controller to operate properly. Press the SETUP Menu button. Press the left or right arrow buttons to move to each function. Press the plus or minus buttons to change the underlined value. Exclude a Program from a Pump Start (only when assigned) Any one of three programs can be excluded from a pump start when a station output has been assigned as a pump start. The factory default is all programs are assigned to a pump start unless otherwise selected. This feature might be used when drip emitters and rotor use the same mainline but only one sprinkler type needs the added delivery pressure. Set Start Times and Water Windows Press the DAYS/TIMES Menu button. Press the plus or minus button to select program A, B, C or D. Press the right or left arrow button to SET STARTS/WINDOWS. Press the SELECT button to edit 1st START/ WINDOW. Press the arrow and plus or minus button in sequence to 2013 HydroPoint Data Systems, Inc. All rights reserved. WTETP3QSPG hydropoint.com

14 WeatherTRAK ET Pro3 Quick Start Programming Guide set the start time and the water window. If a 2nd start time is needed press the right or left arrow button to 2nd START TYPE. Press the plus or minus button to set either High ET or Off. Repeat this procedure for each program used. 1st and 2nd start times cannot overlap and the maximum water window is 24 hrs. Selecting Water Day Mode Press the DAYS/TIMES Menu button. Press the right or left arrow button to WATER DAY MODE (for Program A, B, C or D). Press the plus or minus button to select one of the following seven water day modes: Optimized by WeatherTRAK: ET and individual station settings determine watering days automatically. Press the plus or minus button to exclude a day if needed. Odd/Even: Waters based on Odd or Even calendar days. Press the plus or minus button to select Odd or Even days. Interval: When Interval is selected, press the right or left arrow to WATER DAY INTERVAL. Press the plus or minus button to set the day interval. Day intervals can be set from 1 to 30 days. Days of Week: Uses a 7-day calendar Sunday through Saturday. Press the right arrow to move through each day of the week. Press the plus or minus button to turn days off or on. (Off days shown as a dash ). Days of Week by Month: Uses a 7-day calendar Sunday through Saturday for each month of the year. Press the right arrow button to Jan OK TO WATER ON. Press the right arrow button to move through each day of the week. Press the plus or minus button to turn days off or on. Press the right arrow button to move to the next month. Follow the above procedure for each month of the year. Off: When Off is selected, the controller will ignore programmed starts for the selected program until a different water-day mode is selected. Stations Individual stations are assigned to a program (start time(s), water window and water day mode), and station mode. There are four station modes to select from: Automated by WeatherTRAK, User w/ ET, User No ET and Off. Select the station mode based on the type of landscape to be irrigated. Note: The same station cannot be assigned to different programs. Programming for Existing Landscapes Automated by WeatherTRAK Automatically calculates run times, cycle and soaks for each zone based on zone-specific attributes. Daily ET updates then adjust the calculated run times to reflect current weather conditions. Run times will vary as weather changes. Note: To navigate through the next several screens, press the right arrow button to move to each underlined heading and press the plus or minus button to select a choice within each function. Select Station: Locate the station to be programmed. Select Station Mode: Select Automated by WeatherTRAK. Note: To Preview abbreviated Auto mode station settings for this specific station, press and hold the * button. Select a Program: Assign the station to a program that has a start time and water day mode. Use Water Window: If this station can irrigate outside of the water window, select No. Usable Rainfall: If a station is under a roof, heavy tree canopy or semi-porous roof, select either None or a percent of rainfall that is actually used. When None is selected, the specific station will water during Rain Pause. Sprinkler Type: Select 1 of 13 industry-recognized sprinkler types. When a sprinkler type is selected, a default precipitation rate and sprinkler efficiency value is automatically assigned. Both values can be changed in the next two screens if different than the displayed default rates. Precipitation Rate: Is how much is applied in Inches per Hour. Changing the precip rate will change run times. Lower Precip rates = high run times, Higher Precip rates = lower run times. Sprinkler Efficiency: Every sprinkler applies water with a specific efficiency based on its design and performance and spacing. If head or row spacing is stretched, efficiency is less. (Higher = less water; Lower = more water). Soil Type: Select 1 of 5 soil types determined by the USDA. Plant Type: Select 1 of 17 plant types that best represents the valve zone being irrigated. Root Depth: Press the plus or minus button to select root depth. (Shallow roots = more frequent watering; deep roots = less frequent watering.) Microclimate: Select 1 of 4 levels of sun exposure of the valve zone being irrigated. Slope: Select 1 of 5 slope gradients. The steeper the slope the higher number of cycles will be applied. Sprinkler Location on Slope: Select 1 of 5 choices identifying sprinkler locations on a slope. Next Station: Press the right arrow button to go to the next station or use COPY to duplicate settings to like stations HydroPoint Data Systems, Inc. All rights reserved. WTETP3QSPG hydropoint.com

15 WeatherTRAK ET Pro3 Quick Start Programming Guide User With ET Set run times, number of cycles and the soaks between cycles. It then automatically increases or decreases runtime based on the daily weather information defined as ET. Select Station: Locate the station to be programmed. Select Station Mode: Select User w/ ET Select a Program: Assign station to a program (with a start time, water window and water day mode). Use Water Window: If this station can irrigate outside of the water window, select No. Usable Rainfall: If a station is under a roof, heavy tree canopy or semi-porous roof, select either None or a percent of rainfall that is actually used. When None is selected, the specific station will water during Rain Pause. Set Runtime: Set a desired cycle run time. Set Number of Cycles and the Soak Time: Select from 1-20 cycles and Soak times from 0 to 480 minutes in 10 minute increments. Reference ET: Set a reference ET that is appropriate for the schedule just set. The number you see in parenthesis is ET for the past week and is the value to enter as Part 1 and 2. Alternately, you can set the program you would run in July and use a weekly reference ET that is normal for your area in July. Other Stations: Repeat these steps for other stations assigned to this station mode. Programming for New Landscapes User No ET User No ET is commonly used for plant establishment periods when overwatering is required to establish new roots. Run times, cycle and soak periods are all user defined in this station mode. User No ET sets up the same as User With ET except there is no reference ET. Activation is not required for User No ET. Copy This function lets you quickly copy all station settings from any particular station to any other station or to all stations. Press the COPY Menu button. Press the right or left arrow button to select the station to copy from. Press the plus or minus button to select the station to copy to. ( All Stations is one of the choices.) Push the (*) button until COPYING is displayed. Repeat the process for each station to be copied. Maintenance Tips Manual Watering Stations can be operated individually with specific run times or all stations with one run time. Press the MANUAL Menu button. Select Specific Stations or All Stations by pressing the plus or minus button. Manual Water Specific Stations: Press the right or left arrow button to the first station you want to water. Press the plus or minus button to the minutes desired. The selected station will start immediately. To add more stations, press the right or left arrow button to the next station desired. Manual Water All Stations: Press the plus or minus button to the desired run time. Station 1 will start immediately, and all other active stations will follow sequentially for the same run time. Note: To stop a station that is operating manually press the OFF Menu button for 5 seconds then back to RUN. % Adjust - More or Less Water Adjust Water Amount Adjusts individual stations for more or less water. A 0% setting means there is no adjustment for that particular station. Press the %ADJUST Menu button if valve zone is too wet or too dry. Press the plus or minus button to select the station to adjust in 5% increments from -50% to +25%. Adjust Day Frequency Increases or decreases the number of days of the week per station when water is applied and does not increase the amount being applied unless ET increases. A 0% setting means there is no adjustment for that particular station. Press the plus or minus button to Day Frequency/Depletion. Press the right or left arrow button to ADJ DAYS (MAD). Press the right or left button to select the station to adjust. Note: Using either Adjust function adjusts ET or MAD which will adjust runtimes or frequency of irrigation. Rain Pause - Suspend Irrigation Pause Controller: This feature is useful for major rain events, scheduled activities or any other event where watering must be suspended for a set period of time. Rain Pause stops all irrigation (except manual watering). Press the RAIN PAUSE Menu button. Press the plus or minus button to set the number of days to be paused (up to 200 days). Rain Pause can be reduced or eliminated by using pressing the plus or minus button to remove paused days HydroPoint Data Systems, Inc. All rights reserved. WTETP3QSPG hydropoint.com

16 WeatherTRAK ET Pro3 Quick Start Programming Guide Note: The controller counts down the pause days at the Program A Start time. A controller with 1 day pause will start irrigation right after the next Program A start time. Preview This menu Previews programming changes of individual station data or Flow parameters (if a flow sensor is used and setup). Station Data Press the right or less arrow button to view station data. Press the right or left arrow button to change the station number and the plus or minus button to view projected water days (based on current ET) in one week increments from 1-8 weeks. Displayed station data includes run time, cycle and soak periods, station mode, % adjustments, projected water days on a weekly basis. Flow Data Press the plus or minus button to view Flow Data. Press the right or left arrow button to view previously setup Flow parameters. (If a flow sensor is setup and used). Manual Valve Test Manual Valve Test Function This feature confirms wire integrity between the controller and valves in the field. This test can quickly identify, on a station basis, where an electrical fault exists. Run Manual Valve Test Press the MANUAL Menu button. Press the right or left arrow button to RUN VALVE TEST. Press the plus or minus button to change from Skip to View. Press the (*) button to run the Manual Valve Test. You will hear the controller briefly send a signal to every station including the master valve. Press the right or left arrow button to view the first eight valves. Press the right or left arrow button to view additional stations in groups of eight.? means the test has not been operated and - - means the station does not have an electrical fault. This test cannot be run if any valve is operating. The Controller will identify a (SH) Short (current draw exceeding 1000 ma) or (NC) No Connect reflecting a broken wire. Viewing Solenoid Current Draw The controller will display the milliamp draw of any station solenoid in this test. Step 1. Step 2. Step 3. Step 4. Press the main menu button to SETUP. Press the right arrow button until the following screen appears: RUN VALVE TEST RTVT:OFF Skip 00 SH 00 NC Faults Press the minus button to change the word Skip to View, then press the * button to start the test. It will take about 15 seconds to verify continuity to all stations and the master valve. If any field wiring issues exist, they will be identified as a Fault. A valve fault could be SH (Valve Short) from a failing solenoid or an NC (Valve No-Connect or open) reflecting a broken wire or wire that is not making good contact in the corresponding station terminal. System Shutdown This feature can be found in the OFF menu when a catastrophic event occurs. This feature is not intended for winterization but will stop scheduled irrigation until emergency repairs can be made. Press the OFF Menu button. Press the plus or minus button to locate System Shutdown. The controller will immediately stop all scheduled irrigation and close a normally open master valve until reset by pressing the (*) button in this submenu. Note: Valve alerts must be cleared in the ALERT menu to ensure stations will operate. Failure to clear an alert could suspend watering. If a relay is present, the controller will display an SH because the relay cannot open and close fast enough for the duration of this test HydroPoint Data Systems, Inc. All rights reserved. WTETP3QSPG hydropoint.com

17

18 WeatherTRAK ET Pro3 Flow Reference Guide WeatherTRAK ET Pro3 Flow Reference Guide hydropoint.com

19 WeatherTRAK Flow Reference Guide Flow Alert Clearing This screen provides a choice between (a) allowing the controller to automatically clear flow alerts at the beginning of the scheduled Program A start time, or (b) requiring the user to clear flow alerts manually. If manual operation is selected, irrigation will not occur on alerted stations until the field issue is found and resolved. If there is a flow alert on the master valve, all irrigation will be suspended until the issue is resolved and alerts cleared. Press the minus button to change this value as needed. Press the right arrow button to move to the next screen. Function WeatherTRAK Pro3 offers a flow monitoring feature called Learned Flow. This feature compares individual station flows against a previously learned flow value and will trigger an alert message if a defined flow threshold and delay period is exceeded. Setup All of the Learned Flow setup functions can be found in the Flow menu. To utilize this feature, a compatible flow sensor must be installed and setup properly. (See list of compatible flow sensor below.) Note: WeatherTRAK ET Pro3 series is compatible with Data Industrial IR series and Creative Sensor Technology flow sensor models in various sizes. To configure flow monitoring and learned flow functions, follow the enclosed sequence of screens and submenus. Start by pressing the Flow menu button. Measured Flow This screen displays measured flow at all times, regardless of how many stations are currently operating. If more than one station is operating (scheduled or manual stations), the display will indicate the combined flow rate. If no irrigation is currently operating, but flow is being indicated, the value may indicate a leak situation that needs attention. Press the right arrow button to move to the next screen. Set Flow Meter Size The choices of flow meter sizes are 1, 1.25, 1.50, 2.00, 3.00, 4.00 and Insert Type. Press the minus button to select the size that matches the flow sensor installed. If a flow sensor smaller than 1 is used, then select Insert-Type and enter the K and Offset value for the size being used as found in the manufacturer s installation manual. Press the right arrow button to move to the next screen. View /Edit K and Offset Values When a flow sensor size is selected, its corresponding default K and Offset values are displayed in two consecutive screens and represent PVC piping values. If another piping material is being used, these values can be edited. When edited, the controller will display the default and edited values for comparison. Note: If a flow sensor s K or Offset value is edited and a different size flow meter is selected, the edited value will replace the default value until revised. Press the SELECT button to edit. All characters can be edited including the + and - values. Press the plus or minus button to change the value and the right arrow button to move to the next value. Press the right or left arrow to exit the submenu. If using other compatible flow sensors as identified in the chart below, edit the K Factor and Offset values from the controller s default settings. Select Flow Meter Mode To initiate any flow monitoring functions, the flow meter mode must first be changed from the factory default setting of Off. Press the minus button to change the flow meter mode from Off to 1. Press the right arrow button to move to the next screen HydroPoint Data Systems, Inc. All rights reserved. WTETP3FRG

20 WeatherTRAK Flow Reference Guide Compatible Flow Sensor K and Offset Values Manufacturer Creative Sensor Technology (001 series) Flow Sensor or Hydro Meter Size K Factor Offset / Data Industrial PVC models 735 series ½ series ¾ series series 1-/ Netafim (Register- Type only) /2, 2, 3 & Mainline Break Threshold Generally, selecting a value 20% higher than the station with the highest flow rate will suffice. This value is set in GPM. If two or more stations are being operated at one time, select a GPM that combines the station(s) with the highest flow rate. Station High Flow Threshold Two choices are available; 1) select a % above the learned flow rate. The % is applied to all stations globally. 2) Enter individual station high flow thresholds in GPM. Either method can be used for each station. No Flow Threshold Selecting a flow value at least 15-20% less than the station with the lowest flow rate will suffice. Reference the learned flow values to make this determination. Leak Detect Threshold If a site incorporates quick couplers, hose bibs or a fill pipe for a pond, select a threshold GPM higher than this demand. Setting a Delay Period This represents a time length of how long the controller will wait for flow to stabilize. When the delay expires and a flow threshold is exceeded, the controller will raise an alert and take corrective measures. The factory default period is 3 minutes. The range is 1-6 minutes in 1 minute increments. Edit Excluded Stations from No Flow Alerts In some applications the flow rate varies widely based on the type of sprinklers installed. In some cases the flow rate of the drip emitters is too low to be read accurately. The controller will operate stations, but will not be able to record an accurate flow rate and may falsely post a No Flow Alert. To avoid this occurrence, select stations to be excluded from No Flow Alerts. Press the SELECT button to view the first 8 stations. Press the plus or minus button to change the value from - to EX for exclude. Press the right arrow button to move to the next station or next set of 8 stations up to the controller s max active stations. Pressing the * button on these screens will alternate between selecting all stations and selecting no stations. Press the left or right arrow button to the end to exit the submenu. Setting flow thresholds accurately will reduce the potential for false flow alerts. The following rules of thumb are suggestions to reduce this occurrence. Taking a few moments to record each stations flow rate will provide a reference to make threshold decisions easier and faster. Set Mainline Break Threshold and Delay The mainline break threshold should be higher than the station(s) with the highest flow rate. For example if the station with the highest flow is 60 GPM, then 20% higher would be approximately 75 GPM. For thresholds of 30 GPM and lower, the GPM value can be set in 1 GPM increments, and for GPM values higher than 35 GPM, the increment is 5 GPM. Press the plus or minus button to increase or decrease the factory default value of 50 GPM. Press the right arrow button to select the Delay Period. This value can be changed by pressing the plus or minus button. Press the right arrow button to the next screen. Note: Any Flow Monitoring feature can be turned Off independently of other flow monitoring functions by pressing the right or left arrow button to the zero value, which will display as Off. Set No Flow Threshold and Delay The No Flow Threshold is intended to notify a user if a pump station fails, the backflow device has been shut-off, a remote control valve fails to open, or if an isolation valve in the mainline has been turned off. Set the No Flow threshold at least 15% lower than the station with the lowest flow value. Press the plus or minus button increase or decrease the factory default value of 5 GPM. Press the right arrow button to select the Delay Period. This value can be changed by pressing the plus or minus button. Press the right arrow button to move to the next screen HydroPoint Data Systems, Inc. All rights reserved. WTETP3FRG

21 WeatherTRAK Flow Reference Guide Set Leak Detect Threshold and Delay The controller will continuously monitor for leaks when irrigation is off and during scheduled irrigation with long soak periods when no irrigation is actually operating. The controller will simply post an alert of a leak, but the controller will not take further action. Use the Extended Leak feature to isolate the mainline when normally open master valves are in use. Press the plus or minus button to increase or decrease the factory default value of 15 GPM. Press the right arrow button to select the Delay Period. This value can be changed by pressing the plus or minus button. Press the right arrow to move to the next screen. Set Extended Leak Delay This feature is exclusive to irrigation systems that incorporate normally open master valves where a leak is detected. Corrective action is needed to prevent water wastage or property damage from saturated soil from a continuous leak. If a leak persists beyond the Leak Detect delay period and then beyond the Extended Leak Delay period, the controller will immediately post an Extended Leak Alert and close a normally open master valve. An example of how this works might be when a window washer connects into a quick coupler on the irrigation main to fill buckets of water in order to wash windows. Filling the buckets initially may cause a Leak Detect Alert. If the water is left on beyond the Extended Leak delay time period, the controller will take corrective action. The Extended Leak alert allows normal irrigation to occur as scheduled. If the window washer corrects the condition by turning the water off, the controller will automatically clear the alert after the next irrigation cycle. While remaining in the Leak Detect screen press the right arrow button to the field following + to select the Extended Leak Detect Delay Period. This value can be changed from Off to a selected value by pressing the plus or minus button. The range is minutes in one-minute increments. Press the right arrow button to move to the next screen. Set Station High Flow Offset % The station high flow threshold value can be set using a percentage that applies globally for all stations. The percentage ranges from 5% to 80% above each station s Learned Flow or Assigned Station Flow (ASF) value. The percentage value can be set in 5% increments. Press the plus or minus button to increase or decrease the station high flow offset %. Press the right arrow button to move to the next screen. Note: The Station High Flow Offset is used in the following Station Flow submenu. This submenu lets the user configure each station with a learned flow value using the offset, or with a specific user-defined threshold GPM. View Station Flow In this submenu the controller will display a learned flow value or Assigned Station Flow (ASF) for each station. This value can be (a) a value measured during learning, or (b) a user-defined value. If the station screen displays Unk, the value is not learned or user-defined, and is unknown. Use the arrow buttons and plus and minus buttons to navigate as follows: If the Assigned Station Flow is to be edited, press the plus or minus buttons to set a user-defined value. If a value has been learned and the ASF is not currently the learned value, this will be indicated on the third display line. The learned value can be set by pressing the * button. Press the right arrow button to select Station High Flow Threshold (SHFT). This value can be set to (a) the ASF value plus the Offset set previously, or (b) a user-defined value. Press the plus or minus button to set a user-defined value. If the ASF value is not Unk, pressing the * button sets SHFT to the ASF plus offset value. Press the right arrow button to move to the next station. Learning Station Flow Select Stations to Learn Flow This submenu lets the user select stations on which to Learn Flow. The factory default is No Learn Stations. Learning each station s flow rate is required for the controller to operate, store and then compare for accurate flow monitoring. One or more stations can be selected. Pressing the * button will alternate between selecting all stations and selecting no stations. Note: If a station s flow rate has been previously learned, the controller will only display the most recently learned value. The global station offset percentage is applied to this value. To select a station to Learn Flow, press the SELECT button to view the first 8 stations. Press the plus or minus button to change the value under the corresponding station number of to LF for Learn Flow. Press the right arrow button to move to the next station. Repeat this process as often as needed. Press the right or left arrow button to the end (in either direction) to exit the submenu. Set Delay Before Learning This delay time corresponds to how long the controller will allow flow to stabilize before recording a station s learned flow value. Another way to think about this is selecting the stations run-time. This is a global setting applied to all stations that are learning. If some stations require a longer delay period to ensure accurate recording, they will need to be learned separately with a longer delay period. Allowing too little time for learning could lead to false High Station Flow Alerts. The range of the delay period is 3-10 minutes in 1-minute increments and the factory default value is 3 minutes HydroPoint Data Systems, Inc. All rights reserved. WTETP3FRG

TIS-PRO BIDDING SPECIFICATIONS

TIS-PRO BIDDING SPECIFICATIONS TIS-PRO BIDDING SPECIFICATIONS SPECIFICATIONS TIS-12P-MW TIS-24P-MW TIS-36P-MW TIS-48P-MW TIS-PED Model Number Type Cabinet Style TIS Toro Intelli-Sense 12P 12-station, Professional 24P 24-station, Professional

More information

ET Water SmartWorks Panel Installation Guide

ET Water SmartWorks Panel Installation Guide ET Water SmartWorks Panel Installation Guide You are installing a new piece of equipment that retrofits into an existing irrigation controller in order to create a weather-based irrigation control system.

More information

OWNERS MANUAL FOR STERLING SERIES CONTROLLERS

OWNERS MANUAL FOR STERLING SERIES CONTROLLERS OWNERS MANUAL FOR STERLING SERIES CONTROLLERS 24950 AVENUE KEARNY, VALENCIA, CALIFORNIA 91355-2142 PHONE (661) 257-3533 FAX (661) 257-9472 TABLE OF CONTENTS Selecting the Location for the Controller...3

More information

Please review Chapter 3 and 4 for programming instructions.

Please review Chapter 3 and 4 for programming instructions. Owner's Manual v1.1 This WeatherTRAK Smart Irrigation Controller has earned the U.S. EPA's WaterSense label by meeting the program's water efficiency and performance criteria. Please review Chapter 3 and

More information

OSMAC RDR Low-voltage Retrofit Kit

OSMAC RDR Low-voltage Retrofit Kit OSMAC RDR Low-voltage Retrofit Kit Part Number RDR0160LVN0 User s Guide Installation of the RDR (Radio Data Receiver) low-voltage unit will enable you to remotely operate your existing Vari-Time 4000 satellite

More information

Wireless Rain and Wireless Rain/Freeze Sensor

Wireless Rain and Wireless Rain/Freeze Sensor Wireless Rain and Wireless Rain/Freeze Sensor Installation and Operating Instructions for: WRC: Wireless Rain Sensor Combo WRT: Wireless Rain Sensor Transmitter WSR: Wireless Rain Sensor Receiver WRFC:

More information

Table of Contents. Introduction...3 Specifications...6 Installation Instructions...6

Table of Contents. Introduction...3 Specifications...6 Installation Instructions...6 2 Table of Contents Introduction.............................3 Specifications...........................6 Installation Instructions......................6 Basic Programming To Set Date.............................10

More information

MC-E Installation Instructions & Programming Guide

MC-E Installation Instructions & Programming Guide VALVE MC-E Installation Instructions & Programming Guide 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 YEL VALVE

More information

ET2000e IRRIGATION CONTROLLER

ET2000e IRRIGATION CONTROLLER ET2000e PROGRAMMING GUIDE ET2000e IRRIGATION CONTROLLER PROGRAMMING GUIDE For use with ET2000e irrigation controllers running on firmware version 605.a and above. CHANGE 1 INCORPORATED 30 March 2007 TABLE

More information

Aqua-Gen 3BR INSTRUCTIONS

Aqua-Gen 3BR INSTRUCTIONS Aqua-Gen 3BR INSTRUCTIONS INSTALLATION INSTRUCTIONS CONTROLLER: Find a suitable location to mount the control box* radio note. The controller must be installed out of direct weather and no closer than

More information

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806 Series 500 Analog Transmitters by Data Industrial Data Industrial Owner s Manual Data Industrial 2/95 PN 72806 Table of Contents Introduction... 1 4-20 ma Loop Supply Requirements... 2 Installation...

More information

Important Safety Information

Important Safety Information USER MANUAL Important Safety Information Before using Zuma R300, please be sure to read all operating instructions carefully. Read, follow, and keep these instructions. Heed all warnings. Do not expose

More information

User Manual RME EAGLE. For EG Series Controllers RAINMASTER. Part # Rev.G

User Manual RME EAGLE. For EG Series Controllers RAINMASTER. Part # Rev.G User Manual RME EAGLE For EG Series Controllers RAINMASTER Part # 500042 Rev.G Rain Master Irrigation Systems RME EAGLE User Manual Table of Contents 1.0 INTRODUCTION... 1 2.0 RME EAGLE SPECIFICATIONS...

More information

Table of Contents. - i -

Table of Contents. - i - Rain Master Eagle User Manual Table of Contents Notes iv 1.0 Introduction 1 2.0 Specifications 3 2.1 PROGRAMMING CAPABILITY 3 2.1.1 Water Conservation Features 4 2.1.2 Convenience Features 4 2.1.3 Diagnostic

More information

GB-AVSTOR5 Ceiling Equipment Storage Box with Pipe Coupler

GB-AVSTOR5 Ceiling Equipment Storage Box with Pipe Coupler Ceiling Equipment Storage Box with Pipe Coupler INSTALLATION INSTRUCTIONS CREATING POSITIVE CUSTOMER EXPERIENCES 9534-500-021-00 Contents Weight Limit... 2 Warning Statements... 2 Installation Tools...

More information

Aqua-Gen 3PV INSTRUCTIONS

Aqua-Gen 3PV INSTRUCTIONS Aqua-Gen 3PV INSTRUCTIONS INSTALLATION INSTRUCTIONS CONTROLLER: Find a suitable location to mount the control box* radio note. The controller must be installed out of direct weather and no closer than

More information

Setup Guide. support.spruceirrigation.com.

Setup Guide. support.spruceirrigation.com. FCC Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device

More information

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16 QuadroMAX LED Outdoor Lighting Fixtures Installation Manual QM Series REV: 3/22/16 BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING Risk of fire or electric shock. Luminaire wiring

More information

Grounding and Utility Enclosure

Grounding and Utility Enclosure Grounding and Utility Enclosure UE-1P UE-1P-INS Revision 1 DX Engineering 2006 P.O. Box 1491 Akron, OH 44309-1491 Phone: (800) 777-0703 Tech Support and International: (330) 572-3200 Fax: (330) 572-3279

More information

Expandable Controller 3, 7, 11, 15 stations Installation and Programming Guide

Expandable Controller 3, 7, 11, 15 stations Installation and Programming Guide seconds. This blinking cycle is to go on until the low battery condition is corrected. At that time the normal display returns. Also, while LO BA is blinking, if the dial is turned or any button is pressed,

More information

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL Confirm contents of package: 1 sensor, 1 cable, 1 wide lens (default), 1 narrow lens, mounting template, User s Guide. Install the sensor at the desired

More information

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC. MANUAL PART NUMBER 180-0036 ORIGINAL: 1-17-83 REVISION: B (8-26-86) NOT TO BE CHANGED WITHOUT MSHA

More information

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION Installation and Operation Manual MSI Multi-Sensor Interface Hub Interface Module for all Sensors Network and Wireless CAUTION This equipment complies with the limits for a Class B digital device, pursuant

More information

IRRIGATION CONTROLLER

IRRIGATION CONTROLLER IRRIGATION CONTROLLER 4, 6, 8, 12 or 16 Station Models INSTRUCTION MANUAL INDOOR & OUTDOOR MODELS Table Of Contents Features 1 Glossary 2 Programming Instructions Introduction 3 Programming Example 4 Other

More information

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set #

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set # Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set #1002493 JET 427 New Sanford Road LaVergne, Tennessee 37086 Part No. M-708482 Ph.: 800-274-6848 Revision C3 02/2014 www.jettools.com

More information

6-CYLINDER TORNADO LIFT INSTALLATION MANUAL

6-CYLINDER TORNADO LIFT INSTALLATION MANUAL 6-CYLINDER TORNADO LIFT INSTALLATION MANUAL Model: TORNADO LIFT 18K 2018 Edition PROVIDED FOR ASSEMBLY (4) Foot Pads 16 sq. (4) Square Tube Legs (optional) (2) Cross Beams (2) Side Beams 2.5 Dia. Cylinders

More information

f i r e - p a r t s. c o m

f i r e - p a r t s. c o m Model: CON 1001-1 INSTALLATION AND OPERATING INSTRUCTIONS SINGLE-FUNCTION WIRELESS REMOTE CONTROL SYSTEM FOR OPERATING VALVES WITH ON/OFF LATCHING SOLENOIDS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION

More information

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Gain Electronic Co. Ltd. Table Of Contents Safety Considerations ------------------------------------------------------------2

More information

1-CYLINDER TORNADO LIFT INSTALLATION MANUAL

1-CYLINDER TORNADO LIFT INSTALLATION MANUAL 1-CYLINDER TORNADO LIFT INSTALLATION MANUAL Model: TORNADO LIFT 2K 2018 Edition PROVIDED FOR ASSEMBLY Foot Pads 12 sq. Square Tube Legs (optional) Cross Beams Side Beams 2.5 Dia. Cylinders (with hoses

More information

INSTALLATION MANUAL SONANCE SOUNDBARS SB46 M AND SB46 L. Introduction. Box Contents. Wall Mount Installations

INSTALLATION MANUAL SONANCE SOUNDBARS SB46 M AND SB46 L. Introduction. Box Contents. Wall Mount Installations INSTALLATION MANUAL SONANCE SOUNDBARS SB46 M AND SB46 L Introduction Thank you for purchasing the Sonance Soundbar SB46 M or SB46 L. When properly installed your new Soundbar will give you years of entertainment

More information

Wireless RainSensor Model User s Guide

Wireless RainSensor Model User s Guide Wireless RainSensor Model 53770 User s Guide Contents Page Component Overview................2 Quick Start Installation Instructions......3 Detailed Installation Instructions........4 Mounting the Receiver.............4

More information

LT3000 ULTRASONIC LEVEL TRANSMITTER

LT3000 ULTRASONIC LEVEL TRANSMITTER LT3000 ULTRASONIC LEVEL TRANSMITTER Owner s Manual Specifications Installation Calibration Troubleshooting Warranty Drawings Distributed By: iprocessmart.com 14262 Doolittle Drive San Leandro, CA 94577

More information

A-16D A-Net Distributor

A-16D A-Net Distributor A-16D A-Net Distributor For use with the Personal Monitor Mixing System Information in this document is subject to change. All rights reserved. Copyright 2003 Aviom, Inc. Printed in USA Document Rev. 1.03

More information

PATRIOT DOCKS ASSEMBLY INSTRUCTIONS

PATRIOT DOCKS ASSEMBLY INSTRUCTIONS 6/1/2008 PATRIOT DOCKS ASSEMBLY INSTRUCTIONS Congratulations on your new Patriot Dock purchase. This manual contains instructions to assemble basic dock configurations for use at typical shoreline application.

More information

Beat the Competition. A Remote Will Make Your Crew work smarter not harder and earn more money!!!

Beat the Competition. A Remote Will Make Your Crew work smarter not harder and earn more money!!! Contents Page Number Range Problems 2 TRC Commander Transmitter 3 TRC Commander Receiver 4 SideKick Transmitter 5 SideKick Receiver 5 Permanent Receiver Card for Rainbird ESP MC, SAT, PAR, & Maxicom Controllers

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS CREATING POSITIVE CUSTOMER EXPERIENCES INSTALLATION INSTRUCTIONS Universal Low Profile Tilt Mount for 42 to 63 Flat Panels NORTH AMERICA 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada Phone:

More information

ET2000e IRRIGATION CONTROLLER

ET2000e IRRIGATION CONTROLLER ET2000e IRRIGATION CONTROLLER SPECIFICATION ET2000e IRRIGATION CONTROLLER SPECIFICATION ET2000e IRRIGATION CONTROLLER SPECIFICATION CONTROLLER SPECIFICATION HOW TO SPECIFY CONTROLLER: Step 1 Controller

More information

BCV-1203 Barcode Verification System Users Guide Version 1.2

BCV-1203 Barcode Verification System Users Guide Version 1.2 BCV-1203 Barcode Verification System Users Guide Version 1.2 6 Clock Tower Place Suite 100 Maynard, MA 01754 USA Tel: (866) 837-1931 Tel: (978) 461-1140 FAX: (978) 461-1146 http://www.diamondt.com/ Liability

More information

Installation and Assembly: Articulating Swivel Arm for 37" - 60" Flat Panel Displays

Installation and Assembly: Articulating Swivel Arm for 37 - 60 Flat Panel Displays Installation and Assembly: Articulating Swivel Arm for 37" - 60" Flat Panel Displays Models: PLA60, PLA60-S, PLAV60, PLAV60-S Max UL Load Capacity: 175 lb (79 kg) 2300 White Oak Circle Aurora, Il 60502

More information

Digi-Stop. Installation & Operation

Digi-Stop. Installation & Operation Digi-Stop Installation & Operation WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon

More information

Dial Plus INSTRUCTION MANUAL

Dial Plus INSTRUCTION MANUAL Dial Plus INSTRUCTION MANUAL TABLE OF CONTENTS Features 1 Glossary 2 Programming Instructions Introduction 3 Programming Example 4 Other Functions 5 General tips for programming 5 Programming Set Current

More information

Menu Board Tilt or Fixed Mount Installation Instructions MDS1T-200, MDS1T-300, MDS1T-400 MDS2T-200, MDS2T-300, MDS2T-400 MDS3T-200, MDS3T-300, MDS3T-400 MDS4T-200, MDS4T-300, MDS4T-400 MDS5T-200, MDS5T-300,

More information

Manual Carton Closing Staplers

Manual Carton Closing Staplers Operator s Manual Manual Carton Closing Staplers SHB00-A Item No. 6400 -/8" Crown Carton Closing Stapler 5/8" and /4" (5mm and 8mm) Ask for Genuine INTERCHANGE A58 and A4 Staples SHB50-C Item No. 640 -/4"

More information

300C6 CONTINUOUS HINGE SEMI-FRAMELESS DOOR KIT

300C6 CONTINUOUS HINGE SEMI-FRAMELESS DOOR KIT 300C6 CONTINUOUS HINGE SEMI-FRAMELESS DOOR KIT LIMITED WARRANTY AND REMEDY Alumax Bath Enclosures warrants to its dealers, customers, and all subsequent purchasers and users, that the products supplied

More information

Instruction Manual. The AquaSun 3RP is a premium automatic solar controller with temperature adjustment, manual, winter mode features.

Instruction Manual. The AquaSun 3RP is a premium automatic solar controller with temperature adjustment, manual, winter mode features. Instruction Manual DESCRIPTION The AquaSun 3RP is a premium automatic solar controller with temperature adjustment, manual, winter mode features. Aquasun 3 RP Instruction rb2.docx 1 INSTALLATION INSTRUCTIONS

More information

Field Hub Installation Guide. P/N Rev. C 05/15

Field Hub Installation Guide. P/N Rev. C 05/15 Field Hub Installation Guide P/N016-0171-380 Rev. C 05/15 E21714 Copyright 2015 Disclaimer While every effort has been made to ensure the accuracy of this document, Raven Industries assumes no responsibility

More information

Nocturne+ E INSTRUCTIONS CAUTION. Motor Operated Exterior Projection Screen. 1¾ (45mm) END CAP. Wall Mounting Bracket. Wall Mounting Bracket

Nocturne+ E INSTRUCTIONS CAUTION. Motor Operated Exterior Projection Screen. 1¾ (45mm) END CAP. Wall Mounting Bracket. Wall Mounting Bracket Motor Operated Exterior Projection Screen Wall ing Bracket INSTRUCTIONS INSTALLATION & OPERATION CAUTION Wall ing Bracket 1. Inspect all boxes to make sure you have received the proper screen and parts.

More information

User s Guide Instructions for Installation and Operation

User s Guide Instructions for Installation and Operation User s Guide Instructions for Installation and Operation 2.4 GHZ SPREAD SPECTRUM REMOTE CONTROLS Keyfob Transmitters Models KTX24SS1 KTXW24SS3 KTX24SS2 KTX24SS3 Wall Mount Models NTX24SS1 NTX24SS2 Remote

More information

RAIN-CLIK. Rain Sensor With Optional Freeze Shutoff for Automatic Irrigation Systems. Owner s Manual and Installation Instructions

RAIN-CLIK. Rain Sensor With Optional Freeze Shutoff for Automatic Irrigation Systems. Owner s Manual and Installation Instructions RAIN-CLIK Rain Sensor With Optional Freeze Shutoff for Automatic Irrigation Systems Owner s Manual and Installation Instructions For use with WR-CLIK and WRF-CLIK Sensors TABLE OF CONTENTS Features...3

More information

ApexDesk Assembly Guide

ApexDesk Assembly Guide ELECTRIC HEIGHT-ADJUSTED SIT TO STAND DESK ApexDesk Assembly Guide REV-1507C Table of Contents CAUTION, USE & LIABILITY... 3 PARTS & HARDWARE LIST... 4 PARTS / COMPONENT DIAGRAMS... 5 ASSEMBLY INSTRUCTIONS...

More information

Page 1 of 18. SunRail System Installation Instructions

Page 1 of 18. SunRail System Installation Instructions Page 1 of 18 SunRail System Installation Instructions Page 2 of 18 SunRail Stainless Steel Railing Installation Guide Table of Contents Before You Begin 3 Installing Surface Mount Bases for a Two Rail

More information

ROTORS MP ROTATOR SPRAYS VALVES CONTROLLERS SENSORS CENTRAL CONTROLS MICRO

ROTORS MP ROTATOR SPRAYS VALVES CONTROLLERS SENSORS CENTRAL CONTROLS MICRO ROTORS MP ROTATOR SPRAYS VALVES CONTROLLERS SENSORS CENTRAL CONTROLS MICRO ACC 1 Flow Sensor (HFS): Reports actual flow Put an end to flow emergencies forever. To bring real-time flow sensing to the ACC,

More information

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM Item #1001 510 115 Model DIY-600PS USE AND CARE GUIDE TRANSFORMER Questions, problems, missing parts? Before returning to the store, call HamptonBay Customer Service 8 a.m. - 7 p.m., EST, Monday Friday,

More information

FENCE INSTALLATION GUIDE 8 HIGH WALLS

FENCE INSTALLATION GUIDE 8 HIGH WALLS FENCE INSTALLATION GUIDE 8 HIGH WALLS 1.866.648.9336 www.simtekfence.com INSTALLATION GUIDE These instructions are designed to assist both professional installers and do-it-yourselfers of SimTek decorative

More information

P4263TP. Installation Guide. Low-Profile Tilting Portrait Mount for Flat-Panels

P4263TP. Installation Guide. Low-Profile Tilting Portrait Mount for Flat-Panels Low-Profile Tilting Portrait Mount for Flat-Panels 1321 S. State College Blvd., Fullerton, CA 92831 USA Weight Limit Maximum Flat Panel Weight: 175 lbs. Warning Statements THE WALL STRUCTURE MUST BE CAPABLE

More information

Sensor. Wireless WR-CLIK. WRF-CLIK Wireless Rain/Freeze-Clik. Rain Sensor Shutoff for Automatic Irrigation Systems

Sensor. Wireless WR-CLIK. WRF-CLIK Wireless Rain/Freeze-Clik. Rain Sensor Shutoff for Automatic Irrigation Systems Wireless RAIN LIKTM Sensor Rain Sensor Shutoff for Automatic Irrigation Systems Owner s Manual and Installation Instructions WR-CLIK Wireless Rain-Clik WRF-CLIK Wireless Rain/Freeze-Clik TABLE OF CONTENTS

More information

Stop! Read This Important Information.

Stop! Read This Important Information. Stop! Read This Important Information. Stop, Do Not Proceed, Read This This door replacement kit is designed for the replacement of doors on a Supertop ONLY! This door will not work on any other style

More information

EchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure

EchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure EchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure QS300116 Rev C 2013 Flowline, Inc. All Rights Reserved Made in USA 10500 Humbolt Street, Los Alamitos, CA 90720 USA Tel:

More information

Tilting Flat Panel Wall Mount Installation Guide

Tilting Flat Panel Wall Mount Installation Guide Tilting Flat Panel Wall Mount Installation Guide Model: A580TM Easy installation Built-in level for easy positioning Safety bolts lock the TV on the mount Easy to adjust tilt angles: +5 to -15 degrees

More information

Installation Instructions Hinged Roof Rack

Installation Instructions Hinged Roof Rack Installation Instructions Hinged Roof Rack Application: Jeep Wrangler Unlimited 2004 - Current Part Number: 41435-01 www.bestop.com - We re here to help! Visit our web site and click on Ask a Question

More information

340 & 350 SERIES DELUXE FRAMELESS BYPASS

340 & 350 SERIES DELUXE FRAMELESS BYPASS BATH ENCLOSURES An Alcoa Company Tel: 800-643-1514 Fax: 870-234-3181 www.alumaxbath.com INSTALLATION INSTRUCTIONS 340 & 350 SERIES DELUXE FRAMELESS BYPASS BATH ENCLOSURES Copyright Alumax Bath Enclosures

More information

ASSEMBLY AND INSTALLATION INSTRUCTIONS R , 12, 15, 17, 20, 30, 40 Meters (5/99) COMMUNICATIONS ANTENNAS

ASSEMBLY AND INSTALLATION INSTRUCTIONS R , 12, 15, 17, 20, 30, 40 Meters (5/99) COMMUNICATIONS ANTENNAS ASSEMBLY AND INSTALLATION INSTRUCTIONS R7000 10, 12, 15, 17, 20, 30, 40 Meters COMMUNICATIONS ANTENNAS 951465 (5/99) WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT

More information

Model OI-6940 Notis Quad 4-Gas Sensor Assembly

Model OI-6940 Notis Quad 4-Gas Sensor Assembly Model OI-6940 Notis Quad 4-Gas Sensor Assembly Operation Manual Revision 2.3w Product Overview The Otis Instruments, Inc. Gen II WireFree OI-6940 Notis Quad is a battery-powered explosion-proof 4-gas sensor

More information

Video Wall Installation Instructions 2W X 3H, 3W X 3H

Video Wall Installation Instructions 2W X 3H, 3W X 3H Video Wall Installation Instructions 2W X 3H, 3W X 3H www.microndisplaysolutions.com Table of Contents Important Safety Instructions... 3 Configuration... 4 Package Contents, included and optional items...

More information

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K O P E R A T I N G I N S T R U C T I O N S WEL-200 TM W I R E L E S S E D G E L I N K 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com

More information

340 & 350 SERIES BATH ENCLOSURES

340 & 350 SERIES BATH ENCLOSURES INSTALLATION INSTRUCTIONS 340 & 350 SERIES BATH ENCLOSURES 800-643-1514 www.alumaxbath.com Copyright Alumax Bath Enclosures 2010. All rights reserved. LIMITED WARRANTY AND REMEDY ALUMAX BATH ENCLOSURES

More information

120x165mm. 85x165mm TEMPLATE. ELECTRONIC DEADBOLT model no.: & & Toll-free Number:

120x165mm. 85x165mm TEMPLATE. ELECTRONIC DEADBOLT model no.: & & Toll-free Number: 20x65mm 85x65mm ELECTRONIC EABOLT FOR BACSET 2 3/4" ( 70 mm) FOR BACSET 2 3/8" ( 60 mm) Ø 2 /8" ( 54 mm ) Toll-free Number: -800-268-659 IMPORTANT: Please read this manual carefully before installing this

More information

X-CORE. Residential Irrigation Controller. Owner s Manual and Programming Instructions RUN SYSTEM OFF CURRENT TIME/DAY MANUAL-ONE STATION START TIMES

X-CORE. Residential Irrigation Controller. Owner s Manual and Programming Instructions RUN SYSTEM OFF CURRENT TIME/DAY MANUAL-ONE STATION START TIMES SYSTEM OFF CURRENT TIME/DAY SEASONAL ADJUSTMENT WATER DAYS X-CORE Residential Irrigation Controller RUN SENSOR BYPASS MANUAL-ONE STATION ACTIVE START TIMES RUN TIMES Owner s Manual and Programming Instructions

More information

PORTROD WALL MOUNTED HEIGHT ROD

PORTROD WALL MOUNTED HEIGHT ROD PORTROD WALL MOUNTED HEIGHT ROD USER INSTRUCTIONS P/N UMPORTROD Rev 1-052112 1 PORTROD Thank you for your purchase of this Health o meter Professional product. Please read this manual carefully, and keep

More information

Soil Moisture Smart Sensors (S-SMx-M005)

Soil Moisture Smart Sensors (S-SMx-M005) s (S-SMx-M005) The Soil Moisture smart sensor is used for measuring soil water content and is designed to work with smart sensor-compatible HOBO data loggers. It combines the innovative ECH 2 O Dielectric

More information

Installation Instructions Dual battery Tray Wrangler & Unlimited Part # 2799

Installation Instructions Dual battery Tray Wrangler & Unlimited Part # 2799 Please read instructions entirely before installing this product. Wiring is not included with this part and should be done by an experienced technician. This part is designed to work with Optima Class

More information

Powered by. For further installation assistance: prxperformance.com/pages/murphy-rack

Powered by. For further installation assistance: prxperformance.com/pages/murphy-rack Powered by The 90 Fold-in Murphy Rack is made by the creators of the original Profile Folding Rack at PRx Performance and is Patent Pending. An up-to-date record of patents and patent pending items can

More information

LYNX CE CENTRAL CONTROL FOR NETWORK VP. General Specifications

LYNX CE CENTRAL CONTROL FOR NETWORK VP. General Specifications LYNX CE CENTRAL CONTROL FOR NETWORK VP General Specifications Number of satellites: Up to 500 Number of satellite stations: up to 32,000 Number of Courses: 3 Number of holes per course: 48 Number of holes

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Swingout Arm for 37 to 47 Flat Panels Model: AM80 NORTH AMERICA 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada Phone: 1-800-368-9700 Fax: 1-800-832-4888

More information

MaxLite Linear Strip ECO Series

MaxLite Linear Strip ECO Series General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

FENCE INSTALLATION GUIDE 6 HIGH FENCE

FENCE INSTALLATION GUIDE 6 HIGH FENCE FENCE INSTALLATION GUIDE 6 HIGH FENCE 1.866.648.9336 www.simtekfence.com INSTALLATION GUIDE These instructions are designed to assist both professional installers and do-it-yourselfers of SimTek decorative

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Short Throw Projector Arm Model: UNI-STA/UNI-EXT NORTH AMERICA 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada Phone: 1-800-368-9700 Fax: 1-800-832-4888

More information

IBOC SERIES CONTROLLERS

IBOC SERIES CONTROLLERS irritrd IBOC SERIES BATTERY OPERATED CONTROLLERS OWNER S MANUAL 2, 4, 6, 8 and 10 stations TABLE OF CONTENTS irritrd Thank you for purchasing the IrriTrol IBOC battery operated controller series Listed

More information

Classic Series Public Address Amplifiers C10 & C20 Models

Classic Series Public Address Amplifiers C10 & C20 Models Classic Series Public Address Amplifiers C10 & C20 Models Installation and Use Manual 2009 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-5978-01B 0901

More information

Instruction Sheet REB SERIES. Rotating Sliding Base REB18

Instruction Sheet REB SERIES. Rotating Sliding Base REB18 Instruction Sheet REB SERIES Rotating Sliding Base REB14 REB18 THANK YOU Thank you for purchasing the REB Series Rotating Sliding Base. Please read these instructions thoroughly before installing this

More information

Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS

Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS INTRODUCTION IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE This remote control system

More information

SD-996C-NUQ. Universal Door Strike. Manual

SD-996C-NUQ. Universal Door Strike. Manual SD-996C-NUQ Universal Door Strike Manual 43RG UL Listed. Field selectable for fail-safe or fail-secure Includes 3 faceplates for nearly any type of door: Aluminum frames Hollow metal door frames Wood door

More information

INSTRUCTION BOOK AND PARTS LIST

INSTRUCTION BOOK AND PARTS LIST Rag Cutter MODEL WE WARNING This machine is equipped with a very sharp knife. Keep hands, arms, and hair away from the knife area at all times. Misuse of this machine or failure to follow all safety instructions

More information

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure QS300480 Rev B 2013 Flowline, Inc. All Rights Reserved Made in USA 10500 Humbolt Street, Los Alamitos, CA

More information

SERIES M MIXER MASTS

SERIES M MIXER MASTS SERIES M MIXER MASTS T AB L E O F C O N T E N T S V e n d o r D a t a Material Data Sheet 4-in. Mixer Mast Specification 3-in. Mixer Mast Specification 2 - in. M i x e r M a s t S p e c i f i c a t i o

More information

60 Meter Mono-Band Conversion Kit for the DXE-MBVE-5A Multi-Band Vertical Antenna

60 Meter Mono-Band Conversion Kit for the DXE-MBVE-5A Multi-Band Vertical Antenna 60 Meter Mono-Band Conversion Kit for the DXE-MBVE-5A Multi-Band Vertical Antenna DXE-MBVE-5A60MCK DXE-MBVE-5A60MCK-INS Revision 0a DX Engineering 2017 1200 Southeast Ave. - Tallmadge, OH 44278 USA Phone:

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS P4263F Universal Low Profi le Flat Mount for 42 to 63 Flat Panels NORTH AMERICA 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada Phone: 1.800.368.9700 Fax: 1.800.832.4888

More information

Fletcher F-3000 / F-3100 Accessory Laser Kit

Fletcher F-3000 / F-3100 Accessory Laser Kit Fletcher F-3000 / F-3100 Accessory Laser Kit Shown Assembled on F-3000 Machine Product Warranty The Fletcher-Terry Company warrants the product purchased to be free from defects in parts and workmanship

More information

Taurus CP-300 Single Pump

Taurus CP-300 Single Pump Taurus CP-300 Single Pump The Taurus CP-300 dispenses liquid chemicals with a high degree of accuracy and repeatability. A separately wired remote provides a convenient way to start the cycle. Simple mounting,

More information

SA-027HQ 365-Day Annual Timer

SA-027HQ 365-Day Annual Timer SA-027HQ 365-Day Annual Timer Manual Two N.O. or N.C. Form C relays, 10A@14VDC Each relay can be programmed for 50 events, for a total of 100 individual programmable events 10 Programmable holidays The

More information

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set WALTER MEIER (Manufacturing) Inc. 427 New Sanford Road LaVergne, Tennessee 37086 Part No. M-708482 Ph.: 800-274-6848 Revision C2 02/2013

More information

Installation & User Guide. For Powering Distributed Audio Systems A45-X2 TWO CHANNEL AMPLIFIER

Installation & User Guide. For Powering Distributed Audio Systems A45-X2 TWO CHANNEL AMPLIFIER Installation & User Guide For Powering Distributed Audio Systems TWO CHANNEL AMPLIFIER A45-X2 A45-X2 TWO CHANNEL AMPLIFIER TABLE OF CONTENTS Features...1 Product Overview...2 Package Contents...4 Preparing

More information

Biesemeyer fi T-Square fi Commercial Fence Systems 50 Capacity (Model ) 30 Capacity (Model ) INSTRUCTION MANUAL

Biesemeyer fi T-Square fi Commercial Fence Systems 50 Capacity (Model ) 30 Capacity (Model ) INSTRUCTION MANUAL iesemeyer fi T-Square fi Commercial Fence Systems 50 Capacity (Model 78-904) 30 Capacity (Model 78-907) INSTRUCTION MNUL D T E D 3-5-96 P RT NO. 1349984 'Delta International Machinery Corp. 1996 INTRODUCTION

More information

G75 Irrigation Controller

G75 Irrigation Controller BACCARA G75 Irrigation Controller USERS GUIDE GETTING STARTED TABLE OF CONTENTS FEATURES PARTS IDENTIFICATION BASIC CONTROLLER FUNCTIONS INSTALLATION MANUAL OPERATION MAKING AN IRRIGATION SCHEDULE Irrigation

More information

TABLE OF CONTENTS WARRANTY

TABLE OF CONTENTS WARRANTY DM4000 CONTROL SERIES CONTROLS Instruction Manual Field Programmable Digital Tachometer for Rate and Time P.O. Box 10 5000 W. 106th Street Zionsville, Indiana 46077 Phone (317) 873-5211 Fax (317) 873-1105

More information

Tilting, Swiveling & Rotating Flat Panel Wall Mount

Tilting, Swiveling & Rotating Flat Panel Wall Mount Tilting, Swiveling & Rotating Flat Panel Wall Mount Model: VXA980TC +5 to -5 +5 to -5 Supports most 0-80 Flat Panel TVs Maximum Weight Capacity: 32 lbs. Supports VESA Sizes up to 600x500 For technical

More information

Firmware Version d & higher Installation & Operation

Firmware Version d & higher Installation & Operation DIGI LCD Readout Firmware Version d 2.100 & higher Installation & Operation Warranty Accurate Technology, Inc., warrants this product against defective parts and workmanship for 1 year commencing from

More information

Operating Instructions and Parts Manual SLT-1100 Jumbo Scissor Lift Table

Operating Instructions and Parts Manual SLT-1100 Jumbo Scissor Lift Table Operating Instructions and Parts Manual SLT-1100 Jumbo Scissor Lift Table JET 427 New Sanford Road LaVergne, Tennessee 37086 Part No. M-140780 Ph.: 800-274-6848 Revision B1 05/2014 www.jettools.com Copyright

More information

SD-996C-NUVQ Electric Door Strike with Vertical Adjustment

SD-996C-NUVQ Electric Door Strike with Vertical Adjustment SD-996C-NUVQ Electric Door Strike with Vertical Adjustment Manual 43RG Features: 12/24 VDC Operation Vertical adjustable deadbolt opening, sliding shim keeper, and deadlatch ramp accommodates a wide range

More information

RESIDENTIAL MOTORIZED STORAGE UNIT

RESIDENTIAL MOTORIZED STORAGE UNIT BY V-BRO PRODUCTS RESIDENTIAL MOTORIZED STORAGE UNIT Model: GGR220 INSTALLATION AND OPERATING INSTRUCTIONS Distributed Exclusively by V-BRO PRODUCTS For technical questions and replacement parts, please

More information