MFA - MF enclosed D.C. motors

Size: px
Start display at page:

Download "MFA - MF enclosed D.C. motors"

Transcription

1 MFA - MF example : Data : at 950 min -, - speed drive output voltage 80 V, - supply by thyristor. Operating mode : - reselect the size of the motor using the chart opposite : MFA In the selection table look for the power closest to 0.7 for a form factor of.6 (due to the type of speed drive) (see the following page, an extract of which appears below) : = 0.75 at 2000 min -. How can the rated speed be adjusted to the required speed? By adjusting the armature voltage (speed drive output), without exceeding the rated value, as the power is corrected proportionally. In this case, to be used at 850 min -, the motor will be supplied at = 75.5 V, and = 0.75, or Motor selected : MFA 80 L - 80 V IC MF 2 MF MFA MFA 63 MFA 56 ower min - Speed n M N I η MFA for armature voltage 80 V without excit. size min - N.m A L S S L L L L VL B2.4

2 MFA FF.6 I 44 MFA motor - Class F Field excitation by permanent magnets ower supply by thyristor (form factor.6) S duty - Ambient temperature 40 C - Altitude 000 m n M N I η L R 5 U max Moment MFA for armature voltage 80 V without excit. of inertia size min - N.m A mh Ω V 0-3 kg.m 2 0, ,24 0,6 0, , ,26 56 S 0, ,38 0,58 23, ,5 56 L 0, ,57,2 0, ,7 200,3 63 S 0, ,80,9 0,7 2 4,25 200,7 63 M 0, ,8 2,4 0,75 4,3 2, ,5 63 L 0, ,77 2,7 0, ,5 80 S 0, ,8 3,7 0, , ,5 80 S 0, ,63 3,7 0, , L 0, ,75 5, 0,599 7, L 0, ,58 5, 0, , L 0, ,39 4,9 0,85 8, L ,78 6,6 0,842 20, ,5 80 VL ,8 7,6 0,73 2 0, ,5 80 VL example : see page B2.4. Maximum current which must not be exceeded :.6 times the rated current; otherwise there is a risk that the magnets will be demagnetized.. FF : current form factor. n : Rated speed ± 0 % R 5 : Armature resistance at 5 C B2.5

3 MFA FF.05 I 44 MFA motor - Class F Field excitation by permanent magnets ower supply by thyristor (form factor.05) S duty - Ambient temperature 40 C - Altitude 000 m n M N I η L R 5 U max Moment MFA for armature voltage 80 V without excit. of inertia size min - N.m A mh Ω V 0-3 kg.m 2 0, ,29 0,65 0, , ,26 56 S 0, ,57 0,83 23, ,5 56 L 0, ,96 2, 0, ,7 200,3 63 S 0, ,43 2,6 0,83 2 2,53 200,7 63 M 0, ,75 3,5 0,86 4,3 2, ,5 63 L 0, ,5 3, 0, ,5 80 S 0, ,75 3,7 0, , ,5 80 S 0, ,5 4,5 0, , L 0, ,39 5,3 0,786 7, L 0, ,30 6, 0,82 2 2, L ,8 6,8 0,87 3, L, ,73 7,9 0,844 6, ,5 80 VL, ,4 8,6 0,84 0 0, ,5 80 VL example : see page B2.4. Maximum current which must not be exceeded :.6 times the rated current; otherwise there is a risk that the magnets will be demagnetized.. FF : current form factor. n : Rated speed ± 0 % R 5 : Armature resistance at 5 C B2.6

4 MF 00 L I 44 motor - Class F Separate field excitation : 90 V ± 0 % ower supply by single phase rectified current, with or without S duty - Ambient temperature 40 C - Altitude < 000 m with without Rotation speed n for voltage U M N 50 V 80 V 230 V 250 V 260 V 30 V without I η L R 5 U max min - min - min - min - min - min - N.m A excitation mh Ω V 0,5 0, ,5 4 0, , ,63 0, ,52 4 0, , ,82 0, ,46 4 0, , ,9 0,8 90 6,42 4 0,8 82 5, ,95 0, ,47 4 0, , , ,37 4 0,8 82 5, ,8 0, ,69 5,5 0, , ,96 0, ,60 5,5 0, , ,24, 600 6,57 5,5 0, , ,36, ,55 5,5 0, , ,42, ,52 5,5 0, , ,7, ,5 5,5 0, , ,93 0, ,44 6,7 0,824 64, , ,37 6,7 0,83 64, ,47, ,37 6,7 0,845 64, ,6, ,4 6,7 0,854 64, ,68, ,30 6,7 0,856 64, , ,37 6,7 0,859 64, ,39, ,47 9,6 0,85 30, ,7, ,5 9,6 0,868 30, ,8, ,39 9,6 0,87 30, The values given are for power supply without : form factor FF =.6 ; for FF =.2 (using an additional ), multiply these values by.3. example : see page B2.4. Moment of inertia kg.m 2 Field excitation power at 20 C 60 W R 5 : Armature resistance at 5 C U max : Maximum armature voltage B2.7

5 MF 2 L I 44 motor - Class F Separate field excitation : 90 V ± 0 % ower supply by single phase rectified current, with or without S duty - Ambient temperature 40 C - Altitude < 000 m with without Rotation speed n for voltage U M N 50 V 80 V 230 V 250 V 260 V 30 V without I η L R 5 U max min - min - min - min - min - min - N.m A excitation mh Ω V 0,72 0, ,26 5,4 0, , ,88 0, ,97 5,4 0, , , ,76 5,4 0, , ,25, 90 8,83 5,4 0, , ,3, ,93 5,4 0, , ,58, ,9 5,4 0, , ,6, ,94 8,5 0,808 55, ,4, ,84 8,5 0,86 55, ,84, ,90 8,5 0,835 55, ,0, ,90 8,5 0,839 55, ,, ,83 8,5 0,84 55, ,5 2, ,79 8,5 0,842 55, ,3, ,93 9,4 0,86 44,5 0, ,58, ,9 9,4 0,83 44,5 0, ,05, ,96 9,4 0,838 44,5 0, ,23, ,92 9,4 0,839 44,5 0, ,32 2, ,90 9,4 0,84 44,5 0, ,78 2, ,86 9,4 0,844 44,5 0, ,06, ,69 4 0,867 9,5 0, ,49 2, ,75 4 0,875 9,5 0, The values given are for power supply without : form factor FF =.6 ; for FF =.2 (using an additional ), multiply these values by.3. example : see page B2.4. Moment of inertia kg.m 2 Field excitation power at 20 C 60 W R 5 : Armature resistance at 5 C U max : Maximum armature voltage B2.8

6 MF 2 VL I 44 motor - Class F Separate field excitation : 90 V ± 0 % ower supply by single phase rectified current, with or without S duty - Ambient temperature 40 C - Altitude < 000 m with without Rotation speed n for voltage U M N 50 V 80 V 230 V 250 V 260 V 30 V without I η L R 5 U max min - min - min - min - min - min - N.m A excitation mh Ω V, 0, ,26 8 0,775 5, ,35,6 80 3,68 8 0,8 5, ,75, ,69 8 0,826 5, ,9, ,75 8 0,835 5, , ,8 8 0,84 5, ,4 2, 450 3,83 8 0,848 5, ,25, 950,06 9 0,8 27, ,5,33 40,4 9 0,82 27, ,74 460,38 9 0,84 27, ,5,9 600,34 9 0,845 27, , ,44 9 0,852 27, ,7 2, ,36 9 0,855 27, ,6, ,55,2 0, , ,55,2 0, ,5 2, ,59,2 0, ,7 2, ,55,2 0, ,9 2, ,55,2 0, , ,55,2 0, The values given are for power supply without : form factor FF =.6 ; for FF =.2 (using an additional ), multiply these values by.3. example : see page B2.4. Moment of inertia kg.m 2 Field excitation power at 20 C 50 W R 5 : Armature resistance at 5 C U max : Maximum armature voltage B2.9

ENGINEERING SPECIFICATION

ENGINEERING SPECIFICATION Specifications of the flat and hollow shaft servo actuator Low voltage type SHA25 SHA32 ( CG type ) APPD CHKD BY 2016/ 9/21 T.ICHIKAWA 2016/ 9/21 K.FURUTA 2016/ 9/21 T.Hirabayashi REV DESCRIPTION SHEET

More information

Harmonic Drive Actuator. D C S e r v o S y s t e m s. P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l. RH Mini Series RHS and RFS Series

Harmonic Drive Actuator. D C S e r v o S y s t e m s. P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l. RH Mini Series RHS and RFS Series D C S e r v o S y s t e m s RH Mini Series RHS and RFS Series Total Motion Control Harmonic Drive Actuator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l Precision Gearing & Motion Control

More information

S0L1-J1 - Technical Data Sheet

S0L1-J1 - Technical Data Sheet S0L1-J1 - Technical Data Sheet Standards Stamford industrial alternators meet the requirements of the relevant parts of the IEC EN 60034 and the relevant section of other international standards such as

More information

RH Mini Series. Total Motion Control. Harmonic Drive acutator

RH Mini Series. Total Motion Control. Harmonic Drive acutator D C S e r v o S y s t e m s RH Mini Series Total Motion Control Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l Precision Gearing & Motion Control DC SERVO ACTUATORS

More information

S4L1S-D4 Wdg.17 - Technical Data Sheet

S4L1S-D4 Wdg.17 - Technical Data Sheet - Technical Data Sheet Standards STAMFORD industrial alternators meet the requirements of the relevant parts of the BS EN 60034 and the relevant section of other international standards such as BS5000,

More information

PARTNER ALTERNATORS LSA 40-4 Pole

PARTNER ALTERNATORS LSA 40-4 Pole 23 kva - 50 Hz 12,5 28 kva - 60 Hz 4250 en - 2011.03 / c PARTNER ALTERNATORS LSA 40-4 Pole Electrical and mechanical data SPECIALLY ADAPTED TO APPLICATIONS The LSA 40 alternator is designed to be suitable

More information

Ultimag Rotary Actuators

Ultimag Rotary Actuators Ultimag Rotary Actuators.42 1% Duty Cycle 5% Duty Cycle 1% Duty Cycle.28 Torque - m.14 WARIG: Exposed Magnet may affect pacemakers. In the event a product unit's magnet is exposed due to product disassembly,

More information

3. HIWIN rotary tables TMS

3. HIWIN rotary tables TMS CRD Devices Ltd All Saints Industrial Estate, Shildon, Co, Durham, DL4 2RD Tel: +44 ()1388 7784 Fax: +44 ()1388 7788 E: sales@crd-devices.co.uk W: www.crd-devices.co.uk 3. HIWIN rotary tables TMS 3.1 Characteristics

More information

S4L1D-G41 Wdg Technical Data Sheet

S4L1D-G41 Wdg Technical Data Sheet - Technical Data Sheet Standards Stamford industrial alternators meet the requirements of the relevant parts of the BS EN 60034 and the relevant section of other international standards such as BS5000,

More information

Exercise 1. Basic PWM DC Motor Drive EXERCISE OBJECTIVE DISCUSSION OUTLINE. Block diagram of a basic PWM dc motor drive DISCUSSION

Exercise 1. Basic PWM DC Motor Drive EXERCISE OBJECTIVE DISCUSSION OUTLINE. Block diagram of a basic PWM dc motor drive DISCUSSION Exercise 1 Basic PWM DC Motor Drive EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the most basic type of PWM dc motor drive: the buck chopper dc motor drive. You will

More information

LSA Pole. R 726 Mains paralleling

LSA Pole. R 726 Mains paralleling 498 en-.27 / a Alternators LSA.2-4 Pole Electrical and mechanical data LSA.2-4 Pole SPECIALLY ADAPTED FOR APPLICATIONS The LSA.2 alternator is designed to be suitable for typical generator set applications,

More information

UNIT 9 DC Separately-Excited Generator

UNIT 9 DC Separately-Excited Generator UNIT 9 DC Separately-Excited Generator 9-1 No-Load Saturation Characteristic EXERCISE 9-1 OBJECTIVE After completing this exercise, you should be able to demonstrate the operating characteristic of a DC

More information

FIBRODYN DM DIRECT DRIVEN HIGH-SPEED ROTARY TABLES DATA SHEET COLLECTION

FIBRODYN DM DIRECT DRIVEN HIGH-SPEED ROTARY TABLES DATA SHEET COLLECTION FIBRODYN DM DIRECT DRIVEN HIGH-SPEED ROTARY TABLES DATA SHEET COLLECTION FIBRODYN DM10 Dimensions of FIBRODYN DM10 FIBRODYN DM10.X FIBRODYN DM10.X with control FIBRODRIVE plus Tecnical data for FIBRODYN

More information

INTEGRATED CIRCUITS. AN1221 Switched-mode drives for DC motors. Author: Lester J. Hadley, Jr.

INTEGRATED CIRCUITS. AN1221 Switched-mode drives for DC motors. Author: Lester J. Hadley, Jr. INTEGRATED CIRCUITS Author: Lester J. Hadley, Jr. 1988 Dec Author: Lester J. Hadley, Jr. ABSTRACT The purpose of this paper is to demonstrate the use of integrated switched-mode controllers, generally

More information

Conventional Paper-II-2013

Conventional Paper-II-2013 1. All parts carry equal marks Conventional Paper-II-013 (a) (d) A 0V DC shunt motor takes 0A at full load running at 500 rpm. The armature resistance is 0.4Ω and shunt field resistance of 176Ω. The machine

More information

Part A: Lumped Element Simulation (Saber) Exercise 5: Electronic Motor Controller Last Name First Name Matr.-Nr.

Part A: Lumped Element Simulation (Saber) Exercise 5: Electronic Motor Controller Last Name First Name Matr.-Nr. MSS Lab, Exercise 5: Electronic Motor Controller 1 MSS Lab Part : Lumped Element Simulation (Saber) Exercise 5: Electronic Motor Controller Last Name First Name Matr.-Nr. Prof. Dr.-Ing. G.Schmitz Flugzeug-

More information

Low Voltage alternators - 4 pole LSA 47.2

Low Voltage alternators - 4 pole LSA 47.2 Low Voltage alternators - 4 pole 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Electrical and mechanical data 3782 en - 214.1 / h 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz SPECIALLY ADAPTED TO APPLICATIONS The alternator

More information

Simulation Analysis of SPWM Variable Frequency Speed Based on Simulink

Simulation Analysis of SPWM Variable Frequency Speed Based on Simulink Sensors & Transducers 2014 by IFSA Publishing, S. L. http://www.sensorsportal.com Simulation Analysis of SPWM Variable Frequency Speed Based on Simulink Min-Yan DI Hebei Normal University, Shijiazhuang

More information

Lesson 1 of Chapter Three Single Phase Half and Fully Controlled Rectifier

Lesson 1 of Chapter Three Single Phase Half and Fully Controlled Rectifier Lesson of Chapter hree Single Phase Half and Fully Controlled Rectifier. Single phase fully controlled half wave rectifier. Resistive load Fig. :Single phase fully controlled half wave rectifier supplying

More information

Harmonic Drive actuator

Harmonic Drive actuator Harmonic Drive actuator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l The RSF series servo actuator combines a high performance brushless servomotor with a high accuracy Harmonic Drive gearhead

More information

Improvement of Energy-Capturing Efficiency in Standalone Photovoltaic Systems with Battery Storage

Improvement of Energy-Capturing Efficiency in Standalone Photovoltaic Systems with Battery Storage Proceedings of the 4 th International Middle East Power Systems Conference (MEPCON ), Cairo University, Egypt, December 9-,, Paper ID 95. Improvement of Energy-Capturing Efficiency in Standalone Photovoltaic

More information

Understanding RC Servos and DC Motors

Understanding RC Servos and DC Motors Understanding RC Servos and DC Motors What You ll Learn How an RC servo and DC motor operate Understand the electrical and mechanical details How to interpret datasheet specifications and properly apply

More information

Experiment 2 IM drive with slip power recovery

Experiment 2 IM drive with slip power recovery University of New South Wales School of Electrical Engineering & Telecommunications ELEC4613 - ELECTRIC DRIE SYSTEMS Experiment 2 IM drive with slip power recovery 1. Introduction This experiment introduces

More information

MODELLING AND SIMULATION OF SINGLE PHASE FULL CONTROLLED BRIDGE RECTIFIER FED SEPERATELY EXCITED DC MOTOR.

MODELLING AND SIMULATION OF SINGLE PHASE FULL CONTROLLED BRIDGE RECTIFIER FED SEPERATELY EXCITED DC MOTOR. MODELLING AND SIMULATION OF SINGLE PHASE FULL CONTROLLED EX.NO: Aim: BRIDGE RECTIFIER FED SEPERATELY EXCITED DC MOTOR. DATE: To model and simulate the single phase full wave controlled bridge rectifier

More information

TAL 047 Low Voltage Alternator - 4 pole

TAL 047 Low Voltage Alternator - 4 pole TAL 047 Low Voltage Alternator - 4 pole 4 to 660 kva - 50 Hz / 5 to 825 kva - 60 Hz Electrical and mechanical data Adapted to needs The TAL alternator range is designed to meet the needs of general applications

More information

Stepper Motors WE CREATE MOTION

Stepper Motors WE CREATE MOTION WE CREATE MOTIO PRECIstep Technology EW Page FDM 6 Two Phase with Disc Magnet, AM 8 Two Phase,6 AM Two Phase,6 ADM S Two Phase with Disc Magnet, 6 7 AM Two Phase 6 8 AM Two Phase AM -R Two Phase WE CREATE

More information

Brushed DC Motor System

Brushed DC Motor System Brushed DC Motor System Pittman DC Servo Motor Schematic Brushed DC Motor Brushed DC Motor System K. Craig 1 Topics Brushed DC Motor Physical & Mathematical Modeling Hardware Parameters Model Hardware

More information

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT - Winding 07 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 34 and the relevant sections of other national and international standards

More information

Brushed DC Motor PWM Speed Control with the NI myrio, Optical Encoder, and H-Bridge

Brushed DC Motor PWM Speed Control with the NI myrio, Optical Encoder, and H-Bridge Brushed DC Motor PWM Speed Control with the NI myrio, Optical Encoder, and H-Bridge Motor Controller Brushed DC Motor / Encoder System K. Craig 1 Gnd 5 V OR Gate H-Bridge 12 V Bypass Capacitors Flyback

More information

Speed Feedback and Current Control in PWM DC Motor Drives

Speed Feedback and Current Control in PWM DC Motor Drives Exercise 3 Speed Feedback and Current Control in PWM DC Motor Drives EXERCISE OBJECTIVE When you have completed this exercise, you will know how to improve the regulation of speed in PWM dc motor drives.

More information

Réf / b MS1 - MS2. D.C. motors to 18.5 kw. Technical catalogue

Réf / b MS1 - MS2. D.C. motors to 18.5 kw. Technical catalogue Réf. 1680-2.33 / b - 5.96 MS1 - MS2-0.44 to 18.5 kw Technical catalogue Enclosed and drip-proof 0.06 to 560 kw The LEROY-SOMER range MS1 - MS2 range Enclosed permanent magnet motor Enclosed wound motor

More information

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT - Winding 28 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards

More information

PARTNER ALTERNATORS LSA Pole

PARTNER ALTERNATORS LSA Pole 90 16 kva - 0 Hz 1 6 kva - 60 Hz 38 en - 11.04 / g PARTNER ALTERNATORS LSA 44.2-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 44.2 alternator is designed to be suitable

More information

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT - Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards

More information

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT - Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards

More information

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT - Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards

More information

SGMMV. Rotary Servomotors SGMMV - A1 A 2 A 2 1. Model Designations. 6th. 5th digit. 1st+2nd digits. 7th digit. 4th digit. 3rd digit.

SGMMV. Rotary Servomotors SGMMV - A1 A 2 A 2 1. Model Designations. 6th. 5th digit. 1st+2nd digits. 7th digit. 4th digit. 3rd digit. Rotary s Model Designations - mini Series st+nd digits 3rd digit th digit th digit 6th digit 7th digit st+nd digits Rated Output th digit Design Revision Order 7th digit Options Code Code Code B3 3.3 W

More information

AC SERVO DRIVES SERIES. Rotary Servomotors. Certified for ISO9001 and ISO14001

AC SERVO DRIVES SERIES. Rotary Servomotors. Certified for ISO9001 and ISO14001 C SERVO DRIVES SERIES Rotary Servomotors Certified for ISO91 and ISO141 JQ-422 JQ-EM22 CONTENTS Rotary Servomotors SGMMV (ow Inertia, Ultra-small Size) 4 SGM7J (Medium Inertia, High-speed) 14 SGM7 (ow

More information

Teaching Mechanical Students to Build and Analyze Motor Controllers

Teaching Mechanical Students to Build and Analyze Motor Controllers Teaching Mechanical Students to Build and Analyze Motor Controllers Hugh Jack, Associate Professor Padnos School of Engineering Grand Valley State University Grand Rapids, MI email: jackh@gvsu.edu Session

More information

Siemens AG Rated voltage. field weakening speed,

Siemens AG Rated voltage. field weakening speed, speed Shaft height power torque Speed during ontinuous field weakening speed, ) max. ) Speed, max. ) n rated S P rated M rated I rated V rated n n S n max rpm kw (P) Nm (lb f -ft) V rpm rpm rpm Order No.

More information

23 EZHD synchronous servo motors with hollow shaft

23 EZHD synchronous servo motors with hollow shaft 23 EZHD synchronous servo motors with hollow shaft Table of contents 23 EZHD synchronous servo motors with hollow shaft Table of contents 23.1 Overview... 763 23.2 Selection tables... 764 23.3 Torque/speed

More information

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS PM734D - Winding 312 Technical Data Sheet PM734D SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and

More information

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT PM734F - Winding 312 Technical Data Sheet PM734F SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and

More information

REGULACE AUTOMATIZACE BOR spol. s r.o.

REGULACE AUTOMATIZACE BOR spol. s r.o. REGULACE AUTOMATIZACE BOR spol. s r.o. NOVÝ BOR CATALOG : HSM D.C. SERVO MOTORS All products of the company REGULACE AUTOMATIZACE BOR, spol. s r.o. (Ltd.) are certified by accredited authority for certification

More information

Modelling and Simulation of a DC Motor Drive

Modelling and Simulation of a DC Motor Drive Modelling and Simulation of a DC Motor Drive 1 Introduction A simulation model of the DC motor drive will be built using the Matlab/Simulink environment. This assignment aims to familiarise you with basic

More information

Direct Grid Connection of Permanent Magnet Synchronus Motor Using Auxiliary Inverter and Matrix Converter with Transition Control

Direct Grid Connection of Permanent Magnet Synchronus Motor Using Auxiliary Inverter and Matrix Converter with Transition Control Direct Grid Connection of Permanent Magnet Synchronus Motor Using Auxiliary Inverter and Matrix Converter with Transition Control *Tsuyoshi Nagano, *Jun-ichi Itoh *Nagaoka University of Technology Nagaoka,

More information

RKF Series. Total Motion Control. Harmonic Drive actuator

RKF Series. Total Motion Control. Harmonic Drive actuator RKF Series Total Motion Control Harmonic Drive actuator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l RKF Series The RKF series is compact and includes high-torque AC servo actuators with

More information

Swinburne Research Bank

Swinburne Research Bank Swinburne Research Bank http://researchbank.swinburne.edu.au Tashakori, A., & Ektesabi, M. (2013). A simple fault tolerant control system for Hall Effect sensors failure of BLDC motor. Originally published

More information

Bidirectional PWM DC Motor Drive with Regenerative Braking

Bidirectional PWM DC Motor Drive with Regenerative Braking Exercise 2 Bidirectional PWM DC Motor Drive with Regenerative Braking EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with two better types of PWM dc motor drives: the buck-boost

More information

Static Frequency Converter TMP-TS250. Series

Static Frequency Converter TMP-TS250. Series Static Frequency Converter TMP-TS250 Series Preface SFC is a load commutated inverter LCI, which drives a gas turbine generator like a synchronous motor, and accelerates up to the gas turbine s self-sustaining

More information

Modeling and Analysis of Signal Estimation for Stepper Motor Control. Dan Simon Cleveland State University October 8, 2003

Modeling and Analysis of Signal Estimation for Stepper Motor Control. Dan Simon Cleveland State University October 8, 2003 Modeling and Analysis of Signal Estimation for Stepper Motor Control Dan Simon Cleveland State University October 8, 23 Outline Problem statement Simplorer and Matlab Optimal signal estimation Postprocessing

More information

TETRA COMPACT LOW VOLTAGE BRUSHLESS SERVOMOTORS

TETRA COMPACT LOW VOLTAGE BRUSHLESS SERVOMOTORS TETRA COMPACT LOW VOLTAGE BRUSHLESS SERVOMOTORS BRUSHLESS TECHNOLOGY FEATURES AND BENEFITS Synchronous brushless servomotor, permanently excited Rated output power from 60W to 800W Maximum servomotor speed

More information

Application of Sine Wave DC Inverter Technology in Air Conditioner. Headquarter of Haier Air Conditioner Co., Ltd

Application of Sine Wave DC Inverter Technology in Air Conditioner. Headquarter of Haier Air Conditioner Co., Ltd Application of Sine Wave DC Inverter Technology in Air Conditioner Headquarter of Haier Air Conditioner Co., Ltd 1 Content Key energy-saving technology of air conditioner Comparison of 10 square wave and

More information

Power Electronics (BEG335EC )

Power Electronics (BEG335EC ) 1 Power Electronics (BEG335EC ) 2 PURWANCHAL UNIVERSITY V SEMESTER FINAL EXAMINATION - 2003 The figures in margin indicate full marks. Attempt any FIVE questions. Q. [1] [a] A single phase full converter

More information

TAL 044 Low Voltage Alternator - 4 pole

TAL 044 Low Voltage Alternator - 4 pole TAL 044 Low Voltage Alternator - 4 pole Three-phase 70 to 65 kva - 50 Hz / 88 to 206 kva - 60 Hz Dedicated single-phase 57 to 82 kva - 50 Hz / 80 to 25 kva - 60 Hz Electrical and mechanical data TAL 044

More information

TB6537P/PG,TB6537F/FG

TB6537P/PG,TB6537F/FG TOSHIBA CMOS Integrated Circuit Silicon Monolithic TB6537P/PG,TB6537F/FG TB6537P/PG/F/FG 3-PHASE FULL-WAVE SENSORLESS CONTROLLER FOR BRUSHLESS DC MOTORS The TB6537P/PG/F/FG is a 3-phase full-wave sensorless

More information

The ZSH stepper motor convinces with its robust housing with high-strength cable gland. The motor is waterproof up to 10 m with the IP68 option.

The ZSH stepper motor convinces with its robust housing with high-strength cable gland. The motor is waterproof up to 10 m with the IP68 option. /ZSH HRSH ZSH Stepper otor Robust. Powerful. Reliable. Phytron s HRSHEnvironment motors are particularly suitable for challenging applications in mechanical engineering and industry. Challenging conditions

More information

Static Frequency Converter TMP-TS370. Series

Static Frequency Converter TMP-TS370. Series Static Frequency Converter TMP-TS370 Series Preface SFC is a load commutated inverter (LCI), which drives a gas turbine generator like a synchronous motor, and accelerates up to the gas turbine s self-sustaining

More information

Inductance, capacitance and resistance

Inductance, capacitance and resistance Inductance, capacitance and resistance As previously discussed inductors and capacitors create loads on a circuit. This is called reactance. It varies depending on current and frequency. At no frequency,

More information

Automatic Control Systems 2017 Spring Semester

Automatic Control Systems 2017 Spring Semester Automatic Control Systems 2017 Spring Semester Assignment Set 1 Dr. Kalyana C. Veluvolu Deadline: 11-APR - 16:00 hours @ IT1-815 1) Find the transfer function / for the following system using block diagram

More information

TAL 049 Low Voltage Alternator - 4 pole

TAL 049 Low Voltage Alternator - 4 pole TAL 049 Low Voltage Alternator - 4 pole 730 to 1000 kva - 50 Hz / 915 to 1250 kva - 60 Hz Electrical and mechanical data Adapted to needs The TAL alternator range is designed to meet the needs of general

More information

unit: mm 4130 Parameter Symbol Conditions Ratings Unit Maximum supply voltage 1 V CC 1 max No input signal 50 V Maximum supply voltage 2 V CC

unit: mm 4130 Parameter Symbol Conditions Ratings Unit Maximum supply voltage 1 V CC 1 max No input signal 50 V Maximum supply voltage 2 V CC Ordering number : EN4290A Thick-film Hybrid IC DC 3-phase Brushless Motor Driver (Output Current 3A) Overview The is a hybrid IC incorporating a 3-phase brushless motor controller and driver into a single

More information

Low Cost, Small Package, 120VAC Microstepping Drive

Low Cost, Small Package, 120VAC Microstepping Drive Catalog 8-4/USA E-AC Low Cost, Small Package, 12VAC Microstepping Drive Compumotor's new E-AC is a low-cost, high-performance, high-reliability microstepping drive in a small package. The design of the

More information

Power System Dynamics and Control Prof. A. M. Kulkarni Department of Electrical Engineering Indian institute of Technology, Bombay

Power System Dynamics and Control Prof. A. M. Kulkarni Department of Electrical Engineering Indian institute of Technology, Bombay Power System Dynamics and Control Prof. A. M. Kulkarni Department of Electrical Engineering Indian institute of Technology, Bombay Lecture No. # 25 Excitation System Modeling We discussed, the basic operating

More information

Introducing. CII FCA-150 Series Relay 50 Amps, 1PST/NO (DM) CII FCAC-150 Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts

Introducing. CII FCA-150 Series Relay 50 Amps, 1PST/NO (DM) CII FCAC-150 Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts Introducing CII Series Relay 50 Amps, 1PST/NO (DM) CII Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts Key Features Non-latching relay Balanced force design Corrosion protected metal enclosure

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks -A Load Compact: 20 x 15 x 10 mm (L x W x H). Low power consumption: 200 mw. Flux protection or plastic-sealed construction available.

More information

MD KS synchronous servo motors

MD KS synchronous servo motors Motors MD KS synchronous servo motors 2.8 to 52 Nm Contents General information Technical data Accessories List of abbreviations Product key Product information Functions and features Dimensioning Standards

More information

Renewable Energy Based Interleaved Boost Converter

Renewable Energy Based Interleaved Boost Converter Renewable Energy Based Interleaved Boost Converter Pradeepakumara V 1, Nagabhushan patil 2 PG Scholar 1, Professor 2 Department of EEE Poojya Doddappa Appa College of Engineering, Kalaburagi, Karnataka,

More information

( ) ON s inductance of 10 mh. The motor draws an average current of 20A at a constant back emf of 80 V, under steady state.

( ) ON s inductance of 10 mh. The motor draws an average current of 20A at a constant back emf of 80 V, under steady state. 1991 1.12 The operating state that distinguishes a silicon controlled rectifier (SCR) from a diode is (a) forward conduction state (b) forward blocking state (c) reverse conduction state (d) reverse blocking

More information

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics THE UNIVERSITY OF BRITISH COLUMBIA Department of Electrical and Computer Engineering EECE 365: Applied Electronics and Electromechanics Final Exam / Sample-Practice Exam Spring 2008 April 23 Topics Covered:

More information

Volume 1, Number 1, 2015 Pages Jordan Journal of Electrical Engineering ISSN (Print): , ISSN (Online):

Volume 1, Number 1, 2015 Pages Jordan Journal of Electrical Engineering ISSN (Print): , ISSN (Online): JJEE Volume, Number, 2 Pages 3-24 Jordan Journal of Electrical Engineering ISSN (Print): 249-96, ISSN (Online): 249-969 Analysis of Brushless DC Motor with Trapezoidal Back EMF using MATLAB Taha A. Hussein

More information

Low Voltage alternators - 4 pole LSA 46.2

Low Voltage alternators - 4 pole LSA 46.2 Low Voltage alternators - 4 pole 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Electrical and mechanical data 379 en - 212.11 /h 1-8-POWER-8 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz SPECIALLY ADAPTED TO APPLICATIONS

More information

Robot Actuators. Motors and Control. Stepper Motor Basics. Increased Resolution. Stepper motors. DC motors AC motors. Physics review: Nature is lazy.

Robot Actuators. Motors and Control. Stepper Motor Basics. Increased Resolution. Stepper motors. DC motors AC motors. Physics review: Nature is lazy. obot Actuators tepper motors Motors and Control DC motors AC motors Physics review: ature is lazy. Things seek lowest energy states. iron core vs. magnet magnetic fields tend to line up Electric fields

More information

SPEED CONTROL OF PERMANENT MAGNET SYNCHRONOUS MOTOR USING FPGA FOR HIGH FREQUENCY SIC MOSFET INVERTER

SPEED CONTROL OF PERMANENT MAGNET SYNCHRONOUS MOTOR USING FPGA FOR HIGH FREQUENCY SIC MOSFET INVERTER Journal of Engineering Science and Technology Special Issue on Applied Engineering and Sciences, October (2014) 11-20 School of Engineering, Taylor s University SPEED CONTROL OF PERMANENT MAGNET SYNCHRONOUS

More information

Electrical Drives I. Week 4-5-6: Solid state dc drives- closed loop control of phase controlled DC drives

Electrical Drives I. Week 4-5-6: Solid state dc drives- closed loop control of phase controlled DC drives Electrical Drives I Week 4-5-6: Solid state dc drives- closed loop control of phase controlled DC drives DC Drives control- DC motor without control Speed Control Strategy: below base speed: V t control

More information

2-1 DC DRIVE OVERVIEW EXERCISE OBJECTIVE. Familiarize yourself with the DC Drive. Set the DC Drive parameters to control the DC Motor.

2-1 DC DRIVE OVERVIEW EXERCISE OBJECTIVE. Familiarize yourself with the DC Drive. Set the DC Drive parameters to control the DC Motor. 2-1 DC DRIVE OVERVIEW EXERCISE OBJECTIVE Familiarize yourself with the DC Drive. Set the DC Drive parameters to control the DC Motor. DISCUSSION The DC Drive of your training system is shown in Figure

More information

SYNCHRONOUS MACHINES

SYNCHRONOUS MACHINES SYNCHRONOUS MACHINES The geometry of a synchronous machine is quite similar to that of the induction machine. The stator core and windings of a three-phase synchronous machine are practically identical

More information

MP V-to-16V,1.2A, Single-Phase Brushless DC Motor Driver

MP V-to-16V,1.2A, Single-Phase Brushless DC Motor Driver MP6510 4.5V-to-16V,1.2A, Single-Phase Brushless DC Motor Driver DESCRIPTION The MP6510 is a single-phase, brushless, DC motor driver with integrated power MOSFETs. It drives single-phase brushless DC motors.

More information

Compact drives. Rotary actuators

Compact drives. Rotary actuators Compact drives Rotary actuators Production and delivery of servodrives and control systems. The Czech company TG Drives offers servodrives since 1995 for machines and equipments in industrial automation.

More information

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

Comparative Study of a Small Size Wind Generation System Efficiency for Battery Charging

Comparative Study of a Small Size Wind Generation System Efficiency for Battery Charging SERBIAN JOURNAL OF ELECTRICAL ENGINEERING Vol. 10, No., June 013, 61-74 UDK: 61.354.3 DOI: 10.98/SJEE10707003M Comparative Study of a Small Size Wind Generation System Efficiency for Battery Charging Messaoud

More information

BLDC Motor Speed Control and PFC Using Isolated Zeta Converter

BLDC Motor Speed Control and PFC Using Isolated Zeta Converter BLDC Motor Speed Control and PFC Using Isolated Zeta Converter Vimal M 1, Sunil Kumar P R 2 PG Student, Dept. of EEE. Government Engineering College Idukki, India 1 Asst. Professor, Dept. of EEE Government

More information

Size 23 Single Stack Size 23 Double Stack. 30-in (760 mm) 225 lbs (1,000 N) lbs-ft (30.5 Nm) lbs-ft (26.25 Nm) lbs-ft (30.

Size 23 Single Stack Size 23 Double Stack. 30-in (760 mm) 225 lbs (1,000 N) lbs-ft (30.5 Nm) lbs-ft (26.25 Nm) lbs-ft (30. HAYD: 203 756 7441 BGS Motorized Linear Rails: BGS08 Recirculating Ball Slide BGS08 Linear Rail with Hybrid 57000 Series Size 23 Single and Double Stacks This BGS heavy-duty linear rail combines many technologies

More information

SKS B2 120 GDD 69/11 - A11 MA PB

SKS B2 120 GDD 69/11 - A11 MA PB Absolute maximum ratings 1) Symbol Conditions Values Unit I IN/OUT MAX Maximum permanent input/output current 1 2 A RMS V IN/OUT MAX Maximum output voltage 76 V AC V BUS MAX Maximum DC Bus voltage 1 2

More information

AT7370 FEATURES DESCRIPTION APPLICATIONS. Isolation with active PFC LED Controller (patented) AT KF R SOT-26. Immense Advance Tech.

AT7370 FEATURES DESCRIPTION APPLICATIONS. Isolation with active PFC LED Controller (patented) AT KF R SOT-26. Immense Advance Tech. FEATURES DESCRITIO rimary-side Feedback Constant Current Control Universal Rectified 90VAC to 264VAC Input Voltage Range Boundary Conduction Mode (BCM) Operation with FC (>0.95) Constant Current Control

More information

AC Permanent Magnet and PMDC Brushless Servo Motor Parameters and Conversions

AC Permanent Magnet and PMDC Brushless Servo Motor Parameters and Conversions AC Permanent Magnet and PMDC Brushless Servo Motor Parameters and Conversions AC Permanent Magnet and PMDC Brushless Servo Motor Parameters and Conversions Hurley Gill, Senior Application / Systems Engineer

More information

Technical data. General specifications. Measurement range min max. 360

Technical data. General specifications. Measurement range min max. 360 Model Number Features Very small housing High climatic resistance 12 Bit singleturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

Design and Simulation of Shunt Passive Filter. Design and Simulation of Shunt Passive Filter for Harmonics Mitigation of Non-Linear Loads

Design and Simulation of Shunt Passive Filter. Design and Simulation of Shunt Passive Filter for Harmonics Mitigation of Non-Linear Loads Design and Simulation of Shunt Passive Filter for Harmonics Mitigation of Non-Linear Loads Design and Simulation of Shunt Passive Filter for Harmonics Dung Vo Tien, Mitigation Radomir Gono and ofzbigniew

More information

Introduction to Rectifiers and their Performance Parameters

Introduction to Rectifiers and their Performance Parameters Electrical Engineering Division Page 1 of 10 Rectification is the process of conversion of alternating input voltage to direct output voltage. Rectifier is a circuit that convert AC voltage to a DC voltage

More information

BTA Rotary Actuators. Torque - mnm. 100% Duty Cycle. 25% Duty Cycle 5 50% Duty Cycle 2

BTA Rotary Actuators. Torque - mnm. 100% Duty Cycle. 25% Duty Cycle 5 50% Duty Cycle 2 BTA Rotary Actuators 300 10% Duty Cycle 1 25% Duty Cycle 5 50% Duty Cycle 2 100% Duty Cycle Torque - mnm 200 BTA Brushless Torque Actuators Controllable velocity and position Completely enclosed construction

More information

The typical ratio of latching current to holding current in a 20 A thyristor is (A) 5.0 (B) 2.0 (C) 1.0 (D) 0.5

The typical ratio of latching current to holding current in a 20 A thyristor is (A) 5.0 (B) 2.0 (C) 1.0 (D) 0.5 CHAPTER 9 POWER ELECTRONICS YEAR 0 ONE MARK MCQ 9. MCQ 9. A half-controlled single-phase bridge rectifier is supplying an R-L load. It is operated at a firing angle α and the load current is continuous.

More information

DEPARTMENT OF ELECTRICAL AND ELECTRONIC ENGINEERING BANGLADESH UNIVERSITY OF ENGINEERING & TECHNOLOGY EEE 402 : CONTROL SYSTEMS SESSIONAL

DEPARTMENT OF ELECTRICAL AND ELECTRONIC ENGINEERING BANGLADESH UNIVERSITY OF ENGINEERING & TECHNOLOGY EEE 402 : CONTROL SYSTEMS SESSIONAL DEPARTMENT OF ELECTRICAL AND ELECTRONIC ENGINEERING BANGLADESH UNIVERSITY OF ENGINEERING & TECHNOLOGY EEE 402 : CONTROL SYSTEMS SESSIONAL Experiment No. 1(a) : Modeling of physical systems and study of

More information

AC VOLTAGE CONTROLLER (RMS VOLTAGE CONTROLLERS)

AC VOLTAGE CONTROLLER (RMS VOLTAGE CONTROLLERS) AC VOLTAGE CONTROLLER (RMS VOLTAGE CONTROLLERS) INTRODUCTION AC voltage controllers (AC line voltage controllers): are employed to vary the RMS value of the alternating voltage applied to a load circuit

More information

3.1.Introduction. Synchronous Machines

3.1.Introduction. Synchronous Machines 3.1.Introduction Synchronous Machines A synchronous machine is an ac rotating machine whose speed under steady state condition is proportional to the frequency of the current in its armature. The magnetic

More information

Figure 1: Unity Feedback System. The transfer function of the PID controller looks like the following:

Figure 1: Unity Feedback System. The transfer function of the PID controller looks like the following: Islamic University of Gaza Faculty of Engineering Electrical Engineering department Control Systems Design Lab Eng. Mohammed S. Jouda Eng. Ola M. Skeik Experiment 3 PID Controller Overview This experiment

More information

Eyenubo, O. J. & Otuagoma, S. O.

Eyenubo, O. J. & Otuagoma, S. O. PERFORMANCE ANALYSIS OF A SELF-EXCITED SINGLE-PHASE INDUCTION GENERATOR By 1 Eyenubo O. J. and 2 Otuagoma S. O 1 Department of Electrical/Electronic Engineering, Delta State University, Oleh Campus, Nigeria

More information

Single-phase DC Brushless Motor Driver IC

Single-phase DC Brushless Motor Driver IC Single-phase DC Brushless Motor Driver IC GENERAL DESCRIPTION PACKAGE OUTLINE The NJU7357 is single-phase DC brushless motor driver IC. And It features MOS-FET driver circuit for better output characteristics.

More information

Upgrading from Stepper to Servo

Upgrading from Stepper to Servo Upgrading from Stepper to Servo Switching to Servos Provides Benefits, Here s How to Reduce the Cost and Challenges Byline: Scott Carlberg, Motion Product Marketing Manager, Yaskawa America, Inc. The customers

More information

Series PVG612A & PbF. HEXFET Power MOSFET Photovoltaic Relay Single Pole, Normally Open, 0-60V, 2.0A AC/ 4.0 A DC. General Description.

Series PVG612A & PbF. HEXFET Power MOSFET Photovoltaic Relay Single Pole, Normally Open, 0-60V, 2.0A AC/ 4.0 A DC. General Description. Data Sheet No. PD162 revf Series PVG612A & PbF Microelectronic Power IC HEXFET Power MOSFET Photovoltaic Relay Single Pole, Normally Open, -6V, 2.A AC/ 4. A DC General Description The PVG612A Series Photovoltaic

More information