1 Low Voltage alternators - 4 pole 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Electrical and mechanical data 3782 en / h

2 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz SPECIALLY ADAPTED TO APPLICATIONS The alternator is designed to be suitable for typical generator applications, such as: backup, marine applications, rental, telecommunications, etc. COMPLIANT WITH INTERNATIONAL STANDARDS The alternator conforms to the main international standards and regulations: - IEC 634, NEMA MG , ISO 828-3, CSA / UL 1446 (UL 4 on request), marine regulations, etc. It can be integrated into a CE marked generator. The is designed, manufactured and marketed in an ISO 91 environment and ISO 141. TOP OF THE RANGE ELECTRICAL PERFORMANCE Class H insulation. Standard 12-wire re-connectable winding, 2/3 pitch, type no. 6 (the L9 is available in two versions: 6-wire and 12-wire). Voltage range Hz: 22 V - 24 V and 38 V - 4 V (44 V). Voltage range 6 Hz: 28 V - 24 V and 38 V - 48 V. High efficiency and motor starting capacity. Other voltages are possible with optional adapted windings: - Hz : 44 V (no. 7), V (no. 9), 6 V (no. 23), 69 V (no. 2). - 6 Hz : 38 V and 416 V (no. 8), 6 V (no. 9). R 791 interference suppression conforming to standard EN 11 group 1 class B standard for European zone (CE marking). EXCITATION AND REGULATION SYSTEM SUITED TO THE APPLICATION Excitation system Regulation options Volage regulator SHUNT AREP PMG Current transformer for paralleling Mains paralleling 3-phase sensing 3-phase sensing for mains paralleling unbalanced Remote voltage potentiometer R2 Std R4 Option Std Std C.T. R726 R731 R734 DC Option Option Option C.T. included included included Voltage regulator accuracy ±.% : possible mounting PROTECTION SYSTEM SUITED TO THE ENVIRONMENT The is IP 23. Standard winding protection for clean environments with relative humidity %, including indoor marine environments. Options : Filters on air inlet : derating %. Filters on air inlet and air outlet (IP 44) : derating %. Winding protections for harsh environments and relative humidity greater than %. Space heaters. Thermal protection for windings and shields. REINFORCED MECHANICAL STRUCTURE USING FINITE ELEMENT MODELLING Compact and rigid assembly to better withstand generator vibrations. Steel frame. Cast iron flanges and shields. Twin-bearing and single-bearing versions designed to be suitable for engines on the market. Half-key balancing. Sealed for life ball bearings, regreasable bearings (optional). Standard direction of rotation : clockwise when looking at the drive end view (for anti-clockwise, derate the machine by %). ACCESSIBLE TERMINAL BOX PROPORTIONED FOR OPTIONAL EQUIPMENT Easy access to the voltage regulator and to the connections. Possible inclusion of accessories for paralleling, protection and measurement. 9-way terminal block for voltage reconnection. 2

3 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz General characteristics Insulation class H Excitation system SHUNT (12 wire) AREP or PMG Winding pitch 2/3 (N 6 or N 6S) AVR type R 2 R 4 Number of wires 12 (N 6) / 6 (N 6S) Voltage regulation (*) ±. % ±. % Protection IP 23 Short-circuit current - 3% (3 IN) : s Altitude m Totale Harmonic distortion THD (**) no load < 1.% - on load < 2% Overspeed 22 min -1 Waveform: NEMA = TIF (**) < Air flow.9 m 3 /s (Hz) / 1.1 (6Hz) (*) Steady state. (**) Total harmonic distortion between phases, no-load or on-load (non-distorting) Ratings Hz - R.P.M. kva / kw - P.F. =.8 Duty/T C Continuous duty/4 C Continuous duty/4 C Stand-by/4 C Stand-by/27 C Class/T K H/12 K F/ K H/ K H/163 K Phase 3 ph. 3 ph. 3 ph. 3 ph. Y 38V 4V 4V 38V 4V 4V 38V 4V 4V 38V 4V 4V 22V 23V 24V 22V 23V 24V 22V 23V 24V 22V 23V 24V Y Y 2V 2V 2V 2V 12 wires version VS2 kva kw S4 kva kw S kva kw M7 kva 46 7 kw M8 kva 7 6 kw L9 kva kw wires version Y 38V 4V 4V 38V 4V 4V 38V 4V 4V 38V 4V 4V 22V 23V 24V 22V 23V 24V 22V 23V 24V 22V 23V 24V LSA 47.9 L9* kva kw Ratings 6 Hz - 18 R.P.M. kva / kw - P.F. =.8 Duty/T C Continuous duty/4 C Continuous duty/4 C Stand-by/4 C Stand-by/27 C Class/T K H/12 K F/ K H/ K H/163 K Phase 3 ph. 3 ph. 3 ph. 3 ph. Y 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V 22V 24V 22V 24V 22V 24V 22V 24V Y Y 28V 22V 24V 28V 22V 24V 28V 22V 24V 28V 22V 24V 12 wires version VS2 kva kw S4 kva kw S kva kw M7 kva kw M8 kva kw L9 kva kw wires version Y 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V 22V 24V 22V 24V 22V 24V 22V 24V L9* kva kw * AREP excitation only 3

4 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Efficiencies Hz - P.F.: 1 / P.F.:.8 % VS kva S P.F. : kva.6.8 S P.F. : P.F. : kva M P.F. : kva M P.F. : kva L9 (12 w) L9 (6 w) ,1, P.F. : kva.1 Reactances (%). Time constants (ms) - Class H / 4 V VS2 (12w) S4 (12w) S (12w) M7 (12w) M8 (12w) L9 (12w) L9 (6w) Kcc Short-circuit ratio Xd Direct-axis synchro. reactance unsaturated Xq Quadrature-axis synchro. reactance unsaturated T do No-load transient time constant X d Direct-axis transient reactance saturated T d Short-circuit transient time constant X d Direct-axis subtransient reactance saturated T d Subtransient time constant X q Quadrature-axis subtransient reactance saturated Xo Zero sequence reactance unsaturated X2 Negative sequence reactance saturated Ta Armature time constant Other class H/4 V data io (A) No-load excitation current ic (A) On-load excitation current uc (V) On-load excitation voltage ms Response time ( U = 2% transient) kva Start ( U = 2% cont. or % trans.) SHUNT kva Start ( U = 2% cont. or % trans.) AREP % Transient U (on-load 4/4) SHUNT - P.F.:.8 LAG % Transient U (on-load 4/4) AREP - P.F.:.8 LAG W No-load losses W Heat dissipation

5 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Transient voltage variation 4V - Hz Load application (SHUNT excitation) 2 % 2 VS 2 S 4 S Load application (AREP or PMG excitation) 2 % 2 VS 2 S 4 S kva kva kva at.8 power factor kva at.8 power factor Load rejection (SHUNT excitation) VS 2 S 4 S Load rejection (AREP or PMG excitation) VS 2 S 4 S 3% 3% 2 2 Voltage rise 2 Voltage rise kva kva kva at.8 power factor kva at.8 power factor Motor starting (SHUNT excitation) 3% VS 2 S 4 S Motor starting (AREP or PMG excitation) 3% VS 2 S 4 S kva kva kva Locked rotor kva Locked rotor 1) For a starting P.F. differing from.6, the starting kva must be multiplied by (Sine φ /.8) 2) For voltages other than 4V(Y), 23V() at Hz, then kva must be multiplied by (4/U) 2 or (23/U) 2.

6 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Efficiencies 6 Hz - P.F.: 1 / P.F.:.8 % 91 9 % 91 9 VS P.F. : kva S P.F. : kva M P.F. : kva M P.F. : kva S % P.F. : kva L9 (12 w) L9 (6 w) P.F. : kva Reactances (%). Time constants (ms) - Class H / 48 V VS2 (12w) S4 (12w) S (12w) M7 (12w) M8 (12w) L9 (12w) L9 (6w) Kcc Short-circuit ratio Xd Direct-axis synchro. reactance unsaturated Xq Quadrature-axis synchro. reactance unsaturated T do No-load transient time constant X d Direct-axis transient reactance saturated T d Short-circuit transient time constant X d Direct-axis subtransient reactance saturated T d Subtransient time constant X q Quadrature-axis subtransient reactance saturated Xo Zero sequence reactance unsaturated X2 Negative sequence reactance saturated Ta Armature time constant Other class H/48 V data io (A) No-load excitation current ic (A) On-load excitation current uc (V) On-load excitation voltage ms Response time ( U = 2% transient) kva Start ( U = 2% cont. or % trans.) SHUNT kva Start ( U = 2% cont. or % trans.) AREP % Transient U (on-load 4/4) SHUNT - P.F.:.8 LAG % Transient U (on-load 4/4) AREP - P.F.:.8 LAG W No-load losses W Heat dissipation

7 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Transient voltage variation 48V - 6 Hz Load application (SHUNT excitation) 2 % 2 VS 2 S 4 S Load application (AREP or PMG excitation) 2 % 2 VS 2 S 4 S kva kva kva at.8 power factor kva at.8 power factor Load rejection (SHUNT excitation) Load rejection (AREP or PMG excitation) 3% VS 2 S 4 S 3% VS 2 S 4 S 2 2 Voltage rise 2 Voltage rise kva kva kva at.8 power factor kva at.8 power factor Motor starting (SHUNT excitation) Motor starting (AREP or PMG excitation) 3% VS 2 S 4 S 3% VS 2 S 4 S kva kva Locked rotor Locked rotor 1) For a starting P.F. differing from.6, the starting kva must be multiplied by (Sine φ /.8) 2) For voltages other than 48V(Y), 277V(), 24V(YY) at 6 Hz, then kva must be multiplied by (48/U) 2 or (277/U) 2 or (24/U) 2. 7

8 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz 3-phase short-circuit curves at no load and rated speed (star connection Y) VS2 AREP or PMG Current (A) Symmetrical Asymmetrical SHUNT 1 time (ms) S4 AREP or PMG Current (A) Symmetrical Asymmetrical SHUNT 1 time (ms) S AREP or PMG Current (A) Symmetrical Asymmetrical SHUNT 1 time (ms) Influence due to connection Curves shown are for star (Y) connection. For other connections, use the following multiplication factors: - Series delta : current value x Parallel star : current value x 2 8

9 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz 3-phase short-circuit curves at no load and rated speed (star connection Y) M7 AREP or PMG Current (A) SHUNT Symmetrical Asymmetrical 1 time (ms) M8 AREP or PMG Current (A) Symmetrical Asymmetrical SHUNT 1 time (ms) L9 (6w / 12 w) AREP or PMG Current (A) SHUNT Symmetrical Asymmetrical 1 time (ms) Influence due to short-circuit Curves are based on a three-phase short-circuit. For other types of short-circuit, use the following multiplication factors. 3-phase 2-phase L/L 1-phase L/N Instantaneous (max.) Continuous Maximum duration (AREP/PMG) sec. sec. 2 sec. 9

10 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Single bearing dimensions L Y DIA, X Eq.Sp holes on U P.C.D. A.V.R. AH 14, 33 CF Xg LB ß PMG option Cable 12 Ø P -,127 Ø N -, -, Ø BX Ø ,3 Ø 23 2 x Ø13 Ø AIR OUTLET AIR INLET Access to rectifiers 6 7 S DIA, XBG Eq. Sp. holes on M P.C.D. Dimensions (mm) and weight Coupling Type L without PMG LB Xg Weight (kg) Flex plate 11 1/ VS Flange S.A.E 1 X X S Flange S.A.E 1/2 X S Flange S.A.E X X M M L Flange (mm) Flex plate (mm) S.A.E. P N M XBG S β CF S.A.E. BX U X Y AH / / Xr Torsional analysis data Ø 7 Ø 6 Lr Ø 1 Ø 12 Ø 1 Ø 1 Ø 7 Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm 2 ): (4J = MD 2 ) Flex plate S.A.E. 11 1/2 Flex plate S.A.E. 14 Flex plate S.A.E. 18 Type Xr Lr M J Xr Lr M J Xr Lr M J VS S S M M L NOTE : Dimensions are for information only and may be subject to modifications. Contractuel 2D drawings can be downloaded from the Leroy- Somer site, 3D drawing files are available upon request.

11 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Two bearing dimensions L AVR access 13 Xg LB hole M2x PMG option Cable 12 Ø 713 Ø 2 -,127 Ø 11,17 Ø 8 m6 Ø ,3 Ø 23 2 x Ø AIR OUTLET 68 AIR INLET Diode access 7 M DIA, 12 ep. sp. hole on 3,22 PCD Dimensions (mm) and weight Type L without PMG VS S S M M L LB Xg Weight (kg) Xr 13 Ø 8 Ø 9 Ø 6 Lr Ø 1 Ø 12 Ø 1 Ø 1 Ø 7 Torsional analysis data Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm 2 ): (4J = MD 2 ) Type Xr Lr M J VS S S M M L NOTE : Dimensions are for information only and may be subject to modifications. Contractuel 2D drawings can be downloaded from the Leroy- Somer site, 3D drawing files are available upon request. 11

12 Contact en / a - This document is the property of Moteurs Leroy-Somer, it can not be reproduced in any form without prior written authorization. Moteurs Leroy-Somer reserves the right to modify the design, technical specifications and dimensions of the products shown in this document. The descriptions cannot in any way be considered contractual. Moteurs Leroy-Somer SAS - RCS ANGOULÊME - Capital de

Low Voltage alternators - 4 pole LSA 46.2

Low Voltage alternators - 4 pole LSA 46.2 Low Voltage alternators - 4 pole 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Electrical and mechanical data 379 en - 212.11 /h 1-8-POWER-8 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz SPECIALLY ADAPTED TO APPLICATIONS

More information

PARTNER ALTERNATORS LSA 40-4 Pole

PARTNER ALTERNATORS LSA 40-4 Pole 23 kva - 50 Hz 12,5 28 kva - 60 Hz 4250 en - 2011.03 / c PARTNER ALTERNATORS LSA 40-4 Pole Electrical and mechanical data SPECIALLY ADAPTED TO APPLICATIONS The LSA 40 alternator is designed to be suitable

More information

LSA Pole. R 726 Mains paralleling

LSA Pole. R 726 Mains paralleling 498 en-.27 / a Alternators LSA.2-4 Pole Electrical and mechanical data LSA.2-4 Pole SPECIALLY ADAPTED FOR APPLICATIONS The LSA.2 alternator is designed to be suitable for typical generator set applications,

More information

PARTNER ALTERNATORS LSA Pole

PARTNER ALTERNATORS LSA Pole 90 16 kva - 0 Hz 1 6 kva - 60 Hz 38 en - 11.04 / g PARTNER ALTERNATORS LSA 44.2-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 44.2 alternator is designed to be suitable

More information

TAL 047 Low Voltage Alternator - 4 pole

TAL 047 Low Voltage Alternator - 4 pole TAL 047 Low Voltage Alternator - 4 pole 4 to 660 kva - 50 Hz / 5 to 825 kva - 60 Hz Electrical and mechanical data Adapted to needs The TAL alternator range is designed to meet the needs of general applications

More information

TAL 049 Low Voltage Alternator - 4 pole

TAL 049 Low Voltage Alternator - 4 pole TAL 049 Low Voltage Alternator - 4 pole 730 to 1000 kva - 50 Hz / 915 to 1250 kva - 60 Hz Electrical and mechanical data Adapted to needs The TAL alternator range is designed to meet the needs of general

More information

TAL 044 Low Voltage Alternator - 4 pole

TAL 044 Low Voltage Alternator - 4 pole TAL 044 Low Voltage Alternator - 4 pole Three-phase 70 to 65 kva - 50 Hz / 88 to 206 kva - 60 Hz Dedicated single-phase 57 to 82 kva - 50 Hz / 80 to 25 kva - 60 Hz Electrical and mechanical data TAL 044

More information

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole 30 to 30 kva - 0 Hz / 420 to 63 kva - 60 Hz Electrical and mechanical data Adapted to applications LSA R and LSA H alternators are enclosed alternators

More information

Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva) Alternators: LSA 5, XL8 Ratings 5 Hz 5 rpm kva 66 V 4 poles kva / kwe - Cos φ =,8 3 phase Duty / Ambient Continuous duty (BR) / 4 C PR* / 4 C PR* / 7 C Temperature Rise Class.H/5 K Class.F/5 K 5 K 63 K

More information

S4L1S-D4 Wdg.17 - Technical Data Sheet

S4L1S-D4 Wdg.17 - Technical Data Sheet - Technical Data Sheet Standards STAMFORD industrial alternators meet the requirements of the relevant parts of the BS EN 60034 and the relevant section of other international standards such as BS5000,

More information

S4L1D-G41 Wdg Technical Data Sheet

S4L1D-G41 Wdg Technical Data Sheet - Technical Data Sheet Standards Stamford industrial alternators meet the requirements of the relevant parts of the BS EN 60034 and the relevant section of other international standards such as BS5000,

More information

S0L1-J1 - Technical Data Sheet

S0L1-J1 - Technical Data Sheet S0L1-J1 - Technical Data Sheet Standards Stamford industrial alternators meet the requirements of the relevant parts of the IEC EN 60034 and the relevant section of other international standards such as

More information

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 07. Technical Data Sheet APPROVED DOCUMENT - Winding 07 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 34 and the relevant sections of other national and international standards

More information

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT

PI734F - Winding 28. Technical Data Sheet APPROVED DOCUMENT - Winding 28 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards

More information

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734E - Winding 312. Technical Data Sheet APPROVED DOCUMENT - Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards

More information

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734C - Winding 312. Technical Data Sheet APPROVED DOCUMENT - Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards

More information

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PI734B - Winding 312. Technical Data Sheet APPROVED DOCUMENT - Winding 312 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international standards

More information

ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx

ALTERNATOR TECHNICAL DESCRIPTION 1. LSA 53.2 XL13 / 4p. Chargé d'affaire : Karthikeyan GN 1 Moteurs Leroy-Somer +33 (0) xx ALTERNATOR TECHNICAL DESCRIPTION LSA 53.2 XL3 / 4p LS Reference: 3_66 Date: 426 V4.5G 9/26 Chargé d'affaire : Karthikeyan GN Moteurs LeroySomer +33 ()2 38 6 42 xx Electric Power Generation Orleans prenom.nom@leroysomer.com

More information

PI734C - Technical Data Sheet

PI734C - Technical Data Sheet PI734C - Technical Data Sheet PI734C SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international

More information

WDG 51 - Technical Data Sheet

WDG 51 - Technical Data Sheet MV 804 S WDG 51 - Technical Data Sheet FRAME MV 804 S SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international

More information

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet LV 804 W WDG 12 - Technical Data Sheet FRAME LV 804 W SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international

More information

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet LV 804 R WDG 12 - Technical Data Sheet FRAME LV 804 R SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international

More information

PI734A - Technical Data Sheet

PI734A - Technical Data Sheet PI734A - Technical Data Sheet PI734A SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international

More information

WDG 61 - Technical Data Sheet

WDG 61 - Technical Data Sheet HV 804 W WDG 61 - Technical Data Sheet FRAME HV 804 W SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international

More information

WDG 83 - Technical Data Sheet

WDG 83 - Technical Data Sheet HV 804 R WDG 83 - Technical Data Sheet FRAME HV 804 R SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international

More information

WDG 07 - Technical Data Sheet

WDG 07 - Technical Data Sheet LV 804 S WDG 07 - Technical Data Sheet FRAME LV 804 S SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections

More information

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet LV 804 T WDG 12 - Technical Data Sheet FRAME LV 804 T SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections

More information

WDG 71 - Technical Data Sheet

WDG 71 - Technical Data Sheet HV 804 R WDG 71 - Technical Data Sheet FRAME HV 804 R SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections

More information

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet LV 804 S WDG 12 - Technical Data Sheet FRAME LV 804 S SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections

More information

WDG 13 - Technical Data Sheet

WDG 13 - Technical Data Sheet LV 804 T WDG 13 - Technical Data Sheet FRAME LV 804 T SPECIFICATIONS & OPTIONS STANDARDS Cummins Generator Technologies industrial generators meet the requirements of BS EN 60034 and the relevant sections

More information

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS

PM734D - Winding 312. Technical Data Sheet APPROVED DOCUMENT. Generator Solutions AS PM734D - Winding 312 Technical Data Sheet PM734D SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and

More information

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT

PM734F - Winding 312. Technical Data Sheet APPROVED DOCUMENT PM734F - Winding 312 Technical Data Sheet PM734F SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and

More information

PM734B - Technical Data Sheet. Generator Solutions AS

PM734B - Technical Data Sheet. Generator Solutions AS - Technical Data Sheet STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and certifications can be considered on request. DESCRIPTION

More information

Spec Information. Reactances Per Unit Ohms

Spec Information. Reactances Per Unit Ohms GENERATOR DATA Spec Information Generator Specification Frame: 1647 Type: SR5 No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel: 21.0 Connection: SERIES STAR Housing: 00 Phases: 3 No. of Leads: 6

More information

440 (12) 416 (12) 416 (12) 440 (12)

440 (12) 416 (12) 416 (12) 440 (12) ALTERNATOR DATA SHEET Frame Size LVSI804X CHARACTERISTICS No of Bearings 2 WEIGHTS: Stator Assembly: 10141 lb 4 kg Rotor Assembly: 4184 lb 1898 kg Complete Assembly: 18289 lb 8296 kg MAXIMUM SPEED: 2250

More information

GENERATOR DATA JANUARY 30, 2015

GENERATOR DATA JANUARY 30, 2015 GENERATOR DATA JANUARY 30, 2015 For Help Desk Phone Numbers Click here Generator Specification Frame: 1822 Type: SR5 No. of Bearings: 2 Winding Type: FORM WOUND Flywheel: 21.0 Connection: SERIES STAR Housing:

More information

Spec Information. Reactances Per Unit Ohms

Spec Information. Reactances Per Unit Ohms GENERATOR DATA Spec Information Generator Specification Frame: LC6134K Type: LC No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel: 18.0 Connection: - STAR Housing: 0 Phases: 3 No. of Leads: 6 Poles:

More information

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI144H - Winding 311 APPROVED DOCUMENT. Technical Data Sheet PI144H - Winding 311 Technical Data Sheet PI144H SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards

More information

Packaged Generators: New Kato Engineering Packaged Generator Line: Over 75 Years of Experience: Conformity: Service: Quality Standards:

Packaged Generators: New Kato Engineering Packaged Generator Line: Over 75 Years of Experience: Conformity: Service: Quality Standards: Packaged Generators: New Kato Engineering Packaged Generator Line: The new Kato Engineering line of generators is a group of commercial and industrial quality generators that can meet the broadest range

More information

Low Voltage Alternators - 4 pole

Low Voltage Alternators - 4 pole TAL - A40 - A42 - A44 Electrical and mechanical data Advanced Production Technology Automated winding process to ensure maximum lifespan and reduce human error VPI (vacuum pressure impregnation) insulation

More information

Low Voltage Alternators

Low Voltage Alternators Low Voltage Alternators Excitation and regulation systems SHUNT - PMG - AREP Low Volta SHUNT excitation for basic applications - The AVR power supply voltage is shunted on the alternator output terminals.

More information

AGN 034 Alternator Reactance

AGN 034 Alternator Reactance Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 034 Alternator Reactance DEFINITION Reactance Periods Inherent to the design of an alternator are certain internal

More information

R448 & R448 V50 A.V.R.

R448 & R448 V50 A.V.R. Armature + 6- This manual is to be given to the end user F1 ST5 Field Slow fuse 250V 10 A with LAM without LAM 10 Yellow 11 Red 12 Black 9 Green X2 Z1 X1 Z2 E+ E- 0V 110 22 ST3 requency 50Hz 60Hz LAM 13

More information

R438 A.V.R. Installation and maintenance. This manual is to be given to. the end user CALL US TODAY POWER-58. SHOP ONLINE

R438 A.V.R. Installation and maintenance. This manual is to be given to. the end user CALL US TODAY POWER-58. SHOP ONLINE T1 T7 T2 T8 This manual is to be given to the end user T4 T10 140 mm T5 T11 X2 Z1X1 Z2 E+ E- 0V 110 220 380 200 mm z P1 ST9 AREP PMG This manual concerns the alternator which you have just purchased. We

More information

Generator Advanced Concepts

Generator Advanced Concepts Generator Advanced Concepts Common Topics, The Practical Side Machine Output Voltage Equation Pitch Harmonics Circulating Currents when Paralleling Reactances and Time Constants Three Generator Curves

More information

R448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A

R448 & R448 V50 A.V.R. Installation and maintenance R 448 ST5 ST3 ST10. Armature + 6- Field X2 Z1 X1 Z2 E+ E- 0V Slow fuse 250V 10 A Armature + 6- Field Thismanualistobegivento theenduser F1 ST5 Slow fuse 250V 10 A with LAM without LAM 10 Yellow 11 Red 12 Black 9 Green X2 Z1 X1 Z2 E+ E- 0V 110 22 ST3 requency 50Hz 60Hz ST10 R 448 This

More information

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL Main Features - Compact and heavy-duty industrial model - Interface: Bit-parallel, push pull ΠShort circuit proof - Housing: 58 mm - Shaft: 6 or 10 mm - Resolution: Max. 25 Bit =,554,42 steps over 4,096

More information

R 450. AVRs. Installation and maintenance. This manual is to be given to. the end user R 450 VOLT. STAB. I EXC STAT. LEDS PMG

R 450. AVRs. Installation and maintenance. This manual is to be given to. the end user R 450 VOLT. STAB. I EXC STAT. LEDS PMG 6 5 4 7 8 9 C US 45 en -. / e 5 Hz EXT FREQ 6 Hz SETTING This manual is to be given to the end user VOLT. STAB. I EXC FUSIBLES / FUSES EXT.FREQ. SET. ON ONLY FOR SPECIAL CONFIG. KNEE 5Hz 65Hz 6Hz PHASE

More information

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY 1. The undersigned Interconnection Customer submits this request to interconnect its Large Generating Facility with Transmission

More information

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY Internal Use Only Date Received Time Received Received By: 1. The undersigned Interconnection Customer submits this request to interconnect its Large

More information

4939 en / a PARTNER ALTERNATORS LSA 54. General features and ratings

4939 en / a PARTNER ALTERNATORS LSA 54. General features and ratings 99 en - 00 / a PRTNR LTRNTORS LS eneral features and ratings LTRNTOR : LS M / 0kV - 00V - 0z - 00rpm - P (*) Y connection * PR= Peak rating Reactances (%) - class - 0 kv - 00 V unsaturated Short-circuit

More information

R241 A. 400 Hz A.V.R. Installation and maintenance. This manual is to be given to. the end user C B. Air craft p

R241 A. 400 Hz A.V.R. Installation and maintenance. This manual is to be given to. the end user C B. Air craft p C1 C B Air craft p This manual is to be given to the end user F 0,1A R3 0,1A A 0 F = 6.3A fast - 250 R1 = 100 Ω - R2 = 10 Ω - 1 R3 = 1 KΩ - 2 x 1 mm 2 F R3 Détail This manual concerns the alternator A.V.R.

More information

r 450 Installation and maintenance This manual is to be given to the end user R 450 VOLT. STAB. I EXC STAT. AREP PMG FUSIBLES / FUSES

r 450 Installation and maintenance This manual is to be given to the end user R 450 VOLT. STAB. I EXC STAT. AREP PMG FUSIBLES / FUSES 8 7 9 6 5 4 C 45 en -. / a R 45 DETECT. PH PH. SENSING 5 Hz EXT FREQ 6 Hz SETTING This manual is to be given to the end user VOLT. STAB. I EXC FUSIBLES / FUSES EXT.FREQ. SET. ON ONLY FOR SPECIAL CONFIG.

More information

AGN 005 Fault Currents and Short Circuit Decrement Curves

AGN 005 Fault Currents and Short Circuit Decrement Curves Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 005 Fault Currents and Short Circuit Decrement Curves DESCRIPTION To facilitate the correct design of an electrical

More information

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

Rotek AS440 compatible VOLTAGE REGULATOR (AVR) Rotek AS440 compatible VOLTAGE REGULATOR (AVR) SPECIFICATION INSTALLATION AND ADJUSTMENTS General description Technical specification AS440 is a half wave phase controlled thyristor type AVR and forms

More information

D I G I T A L V O L T A G E R E G U L A T O R

D I G I T A L V O L T A G E R E G U L A T O R The Cat Digital Voltage Regulator is a microprocessor based control designed to provide precise voltage control, robust transient response, and generator protection with industry leading features and versatility.

More information

Rotary Measurement Technology Incremental Encoders

Rotary Measurement Technology Incremental Encoders -20 to 60 C Temperature Shock/vibration resistant Short-circuit protection Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection

More information

Technical Data Sheet for AvK-Alternators

Technical Data Sheet for AvK-Alternators Technical Data Sheet for AvK-Alternators FM 7.3-5 Date: 8/1/14 Customer: GENERIC DATASHEET only Project No.: AvK Reference: dsg114l1_6_5_69_a48m988 Object data: Site: Prime Mover: Application: Stationary

More information

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector Characteristics integrated drive ILA with servo motor - 24..48 V - EtherCAT - indus connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network

More information

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR) AS440 AUTOMATIC VOLTAGE REGULATOR (AVR) SPECIFICATION INSTALLATION AND ADJUSTMENTS General description Technical specification AS440 is a half wave phase controlled thyristor type AVR and forms part of

More information

HCM634G - Technical Data Sheet

HCM634G - Technical Data Sheet HCM634 - Technical Da Sheet HCM634 SPECIFICATIONS & OPTIONS TERMINALS & TERMINAL BOX Marine gs may be ctified to Lloyds, DnV, Bureau Vitas, ABS, manisch-lloyd RINA. Oth standards and ctificio can be coided

More information

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange) D3G46-AH- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court

More information

Technical Data Sheet for AvK-Alternators

Technical Data Sheet for AvK-Alternators Technical Data Sheet for AvK-Alternators FM 7.3-5 Date: 9/1/13 Customer: GENERIC DATASHEET only Project No.: AvK Reference: dig156l_6_6_138 Object data: Site: Prime Mover: Application: Stationary Power

More information

Technical Data Sheet for AvK-Alternators

Technical Data Sheet for AvK-Alternators Technical Data Sheet for AvK-Alternators FM 7.3-5 Date: 9/1/13 Customer: GENERIC DATASHEET only Project No.: AvK Reference: dig13k_4_5_33 Object data: Site: Prime Mover: Application: Stationary Power Plant

More information

Application Guidance Notes: Technical Information from Cummins Generator Technologies

Application Guidance Notes: Technical Information from Cummins Generator Technologies Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 007 - Testing POLICY The following is offered as an eplanation of the policy and procedures followed by Cummins

More information

Technical Data Sheet for AvK-Alternators

Technical Data Sheet for AvK-Alternators Technical Data Sheet for AvK-Alternators FM 7.3-5 Date: 3/9/13 Customer: Bitte Interessent eingeben! Project No.: AvK Reference: 1-67-83-1 Object data: Site: Prime Mover: Application: Stationary Power

More information

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution Features Robust, compact housing Two bearings with large distance, one at each end High shaft load up to 450 N Shock resistant up to 250 g Shaft insulation up to 2.8 kv Highest operating speed 10000 rpm

More information

Generation Interconnection Study Data Sheet Synchronous Machines

Generation Interconnection Study Data Sheet Synchronous Machines FOR INTERNAL USE ONLY GTC Project Number: Queue Date: Generation Interconnection Study Data Sheet Synchronous Machines Customers must provide the following information in its entirety. GTC will not proceed

More information

4938 en / a PARTNER ALTERNATORS LSA General features and rating4

4938 en / a PARTNER ALTERNATORS LSA General features and rating4 9 en - 00 / a PRTNR LTRNTORS LS eneral features and rating LTRNTOR : LS M0 / 000kV - 00V - 0z - 00rpm - P (*) Y connection * PR= Peak rating Reactances (%) - class - 000 kv - 00 V unsaturated Short-circuit

More information

ABSOLUTE ROTARY ENCODER DEVICE NET

ABSOLUTE ROTARY ENCODER DEVICE NET Main Features - Compact and heavy-duty industrial model - Interface: CAN according to Device Net - Housing: 8 mm - Shaft: 6 or 0 mm - Resolution: Max. 2 Bit =,,2 steps over,096 revolutions - Code: Binary

More information

ABSOLUTE ROTARY ENCODER SSI

ABSOLUTE ROTARY ENCODER SSI Main Features - Compact and heavy-duty industrial model - Interface: Synchronous-serial (RS422/485) - Housing: 58 mm - Shaft: 6 or 10 mm - Resolution: Max. 25 Bit =,554,42 steps over 4,096 revolutions

More information

Conventional Paper-II-2013

Conventional Paper-II-2013 1. All parts carry equal marks Conventional Paper-II-013 (a) (d) A 0V DC shunt motor takes 0A at full load running at 500 rpm. The armature resistance is 0.4Ω and shunt field resistance of 176Ω. The machine

More information

IP65 Splash and Dust Proof Stepping Motors

IP65 Splash and Dust Proof Stepping Motors IP5 Splash and Dust Proof Stepping Motors CE/UL Model Features These IP5 rated motors* have superior water and dust resistance, and can be safely utilized in harsh or wet environments such as in food processing

More information

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC Characteristics time delay relay 8 functions - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range

More information

STAR ELECTRIC COMPANY

STAR ELECTRIC COMPANY STAR ELECTRIC COMPANY STECO manufacturers a complete range of Energy Efficient Mors conforming IS: 325. Efficiency class Improved efficiency PRODUCT RANGE International Standards 60034-1,5 60072 Rotating

More information

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a The Heavy Duty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS

More information

AGN 124 AVR Power Supplies

AGN 124 AVR Power Supplies Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 124 AVR Power Supplies DESCRIPTION The simplest way to provide a power supply for an AVR is to take power directly

More information

3 - Protection components Circuit-breakers

3 - Protection components Circuit-breakers Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

RoHS. High shaft load capacity. Shock / vibration resistant

RoHS. High shaft load capacity. Shock / vibration resistant Due to their sturdy bearing construction in Safety Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up

More information

847H. Description. Features. Specifications

847H. Description. Features. Specifications 847H Bulletin 847H High Performance Industrial Incremental Encoders provide code disk resolutions of up to 65536 pulses per revolution at a signal frequency response of 820 khz. The 847H can provide 65536

More information

ABSOLUTE ROTARY ENCODER CAN-BUS

ABSOLUTE ROTARY ENCODER CAN-BUS Main Features - Compact and heavy-duty industrial model - Interface: CAN according to CAL - Housing: 8 mm - Shaft: 6 or 0 mm - Resolution: Max. 2 Bit =,,2 steps over,096 revolutions - Code: Binary - EMC:

More information

Impact Assessment Generator Form

Impact Assessment Generator Form Impact Assessment Generator Form This connection impact assessment form provides information for the Connection Assessment and Connection Cost Estimate. Date: (dd/mm/yyyy) Consultant/Developer Name: Project

More information

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)

More information

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V Technical Data Sheet Uninterruptible Power Supply On-line VH Series UPS 2000-3000 UL / 208V GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850

More information

AGN 124 AVR Power Supplies

AGN 124 AVR Power Supplies Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 124 AVR Power Supplies DESCRIPTION The simplest way to provide a power supply for an AVR is to take power directly

More information

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H018F1 variable speed drive ATV kW hp V - 1ph Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 100..120V - 1ph Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component

More information

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application

More information

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal R3G3-RO36-8 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court

More information

VOLTAGE REGULATOR R 449. Installation and maintenance. This manual must be sent to the end user R 449 X2 Z1 X1 Z2 E+ E- (12V - 10A)

VOLTAGE REGULATOR R 449. Installation and maintenance. This manual must be sent to the end user R 449 X2 Z1 X1 Z2 E+ E- (12V - 10A) This manual must be sent to the end user X2 Z1 X1 Z2 E+ E- J1 t (12V - 10A) ~ 10 ohms Exciter field + - Isolated DC power supply Installation and maintenance WARNING TO AVOID HARM EITHER TO PEOPLE OR TO

More information

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC Characteristics adjustable symmetrical flashing relay - 0.05..1 s - 24 V AC DC - 2OC Price* : 202.00 USD Discontinued Main Range of product Product or component type Contacts type and composition Component

More information

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol Product datasheet Characteristics ATV12HU22M2 Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component name Variable

More information

K Factor Power Transformers

K Factor Power Transformers Ashley-Edison AsiaElectricTransformers (UK) K Factor Power Transformers DTKF series Low Voltage Dry Type K Factor Power Transformers AET-DTKF-2004-01: Page 1 Asia Electric Transformers, Entrepreneur Business

More information

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink Characteristics variable speed drive ATV12-4kW - 5hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution Features TTL output driver for cable length up to 550 m Very high resistance to shock and vibrations Hybrid bearing for extended service life Shaft insulation up to.8 kv Large terminal box, turn by 80

More information

Protection components

Protection components General Application LT3-Si thermistor protection units continuously monitor the temperature of the machines to be protected (motors, generators, etc.) by means of PTC thermistor probes embedded in the

More information

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS 2-1. General but less than locked-rotor amperes and flows only Electrical power systems must be designed to serve in the normal circuit path. a variety of

More information

Rotary Measurement Technology Absolute Encoders, Multiturn

Rotary Measurement Technology Absolute Encoders, Multiturn Mechanical drive Safety-LockTM High rotational speed -40 to 90 C IP Temperature High IP High shaft load capacity Shock/ vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection

More information

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW Characteristics soft starter for asynchronous motor - ATS01-12 A - 110..480V - 1.5..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application

More information

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW Characteristics soft starter for asynchronous motor - ATS01-25 A - 110..480V - 2.2..11 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device

More information