MONTHLY REPORT OF HPT Bareilly DDNational(Ch#8) & DDNews(CH#21 ) for the month of SEPTEMBER
|
|
- Elisabeth Sparks
- 5 years ago
- Views:
Transcription
1 MONTHLY REPORT OF Bareilly DDNational(Ch#8) & DDNews(CH#21 ) for the month of SEPTEMBER GENERAL 1.1 DETAILS OF IMPORTANT TECHNICAL WORK DONE DURING THE MONTH Name of Station DDK Bareilly Details of the important technical work done 400KVA 33KV/415V 3phase transformer was become defective on & taken out of circuit REMARKS Standby transformer 500KVA for transmitter was used on for DDK Residential Power Supply. Demanded one No. 400 KVA 33KV/415V transformer or repairing existing one.
2 DD#1 1. General cleaning 7F & 8F stages of the transmitter was done. 2. Blower Room/ Filters were cleaned to avoid tripping of the transmitter. On load changeover switch Havells, Model IEC 947-III 4 pole,800a,415v,50hz in panel become malfunction (3 phase connection are not proper)- it is required to be bypassed / needs new c/o switch. 8F(BEL 15000cx) valve urgently required as no spare valve in working condition available at V Urgent requirement of Diode D12-C13CUR, Capacitor 300pF, 10KV cap 1000PF/15KV & Resister 50 ohm, 150 W carbon rod resisters used in 8F stage. Power will become 1kW on failure of these components. No spare parts are available at Tech. store Bly. 28V/50A or 25A - 02 No. SMPS power supply is urgently required. DD#N 1. In 100 KVA AVR make-ae its one phase control was not working on auto mode. It was checked and its control card H-99 was found defective. The same card purchased from AE Company and replaced in it. Now, this AVR is working OK. 2. ATV Encoder changed with new one. 3. Under supervision of Shri Satyapal Ji, ADE(E), New Delhi, status of all PA checked and following works were done. (i) The phase of some Pas were found disturbed. Set it right. (ii) Repaired VPA s line transmitter, driver. Low. Of set current setting. As per instruction of ADG(NZ) office one ATV Encoder unit was handedover to CE(NZ) office in May 11 There is no spare ATV encoder unit is available at,in spare Exciter it is not working. Four No. vision PA are defective (suspected preamplifier) required to be repair at Zonal workshop.
3 1.2 DETAILS OF OFFICERS / STAFF RELIEVED / JOINED FROM / AT DURING THE MONTH DETAILS OF OFFICERS / STAFF JOINED Name Desig. Relieved from Station Relieving Date Joined at Joining date Transfer order No. and Date Dr. Sanjay PEX CPC New DDK Kumar Delhi Bareilly DETAILS OF OFFICERS / STAFF RELIEVED Name Desi. Relieved from Station Relieving Date To join at Transfer order No. and Date TOUR / LEAVE DETAILS OF HEAD OF OFFICE / STAFF DURING THE MONTH NAME OF OFFICER TOUR DETAILS PERIOD OF E.L. / MEDICAL PERIOD PLACE LEAVE ALONGWITH ITS NATURE TRAINING DETAILS OF HEAD OF OFFICE / STAFF DURING THE MONTH NAMEOF OFFICER / STAFF DESIGNATION PERIOD PLACE NAME OF COURSE From TO 1.5 DETAILS OF NEW EQUIPMENT RECEIVED AT STATION DURING LAST SIX MONTHS Name Of Name of Equipment Date of receipt of Receiv ed from Wheth er put Performance of equipment Remarks
4 Transmitter DD-1 (i) Power quality analyzer (ii) Dehydr DDNews PGF / Studio (iii) ator Desktop computer Modulator Assembly, PCU P/S, PUC Software kit ZK610, Coolant, Atteunator Beta Cam tapes 60 Mts 20 nos. 90 mts. 20 nos. equipme nt May-14 May-14 D-6 D-6 in to circuit -- May-14 OK OK -- ADG(N Z) OK OK CP&S May-14 CP&S DETAILS OF SCROLLER Name of Station Working Status of Scroller-1 Working Status of Scroller-2 Revenue generated in current month Progressive revenue generated in current financial year N/A N/A N/A N/A N/A 1.7 ELECTRIC CONNECTION DETAILS Name of Station Sanctioned Load Power Factor Numbers of feeder Capacity & No. of HT Transformers Phase Voltages (Feeder-1) Phase Voltages (Feeder-2) DDK BAREILLY 675 KW Billing under HV1(B)- Revised rates 0.90 to 0.92 ONE 500KVA-2 NOS 400 KVA-1 No. (One number 400 KVA defective on , so standby 500 KVA transformer of transmitter was 33KV N/A
5 2. TECHNICAL used for DDK residential power supply. No spare transformer for XTR is available now. 2.1 DETAILS OF WORKING OF TRANSMITTER FOR THE MONTH DD-1 DD-News 1 Test Hours Scheduled Prog. Hours Gear Breakdown Hrs Power Supply Breakdown Hrs Other Causes Breakdown Hrs Total Breakdown Hrs. (3+4+5) Prog. Hours Radiated (2-6) Total Hours of Working (1+7) % B/D ={(Total B/D x 100)/ Scheduled Prog. Hrs.)} 0.211% 2.3% 2.2 PROGRESSIVE TOTAL FROM APRIL OF CURRENT FINANCIAL YEAR DD-1 DD-News 1 Test Hours Scheduled Prog. Hours Gear Breakdown Hrs Power Supply Breakdown Hrs Other Causes Breakdown Hrs Total Breakdown Hrs. (3+4+5) Prog. Hours Radiated (2-6) Total Hours of Working (1+7)
6 9 % B/D ={(Total B/D x 100)/ Scheduled Prog. Hrs.)} 0.198% 0.54% 2.3 DETAILS OF POWER OF TRANSMITTER FOR THE MONTH DD-1 DD-News 1 Rated Power of Transmitter (in KW / Watts) KW Forward Peak Power of 2 Transmitter Video 9.0KW 20 KW Audio 400W 356watt 3 Reflected Power Video 50W 153W Audio 0W 8W 4 Since when Transmitter is on less than rated power (if applicable) 5 Reasons for less than rated power F plate transformer 6 Reasons for high reflection, if any DETAILS OF LOW POWER RADIATION FROM TRANSMITTER (Sync Peak Video Power less than rated power) -- DD#1 DD#N 1 Dates 2 Duration 3 Power (Radiation) 4 Reasons 5 Total duration of Low Power in hours during the month 6 No. of occurrences One 7 Progressive total of occurrences of One - Low Power Radiation 8 Progressive total of duration of Low Power Radiation Complaints of reception, if any & Reason of complaints Complaints recd. from viewers No complaints Received
7 regarding week signal 2.5 DETAILS OF MAJOR BREAKDOWN DURING THE MONTH (More than 15 minutes) DD-1 Date Duration Period Reasons for B/D From To nil Action taken to solve the B/D Preventive action taken to avoid such breakdown in future DD-News Date Duration Period Reasons for B/D From To Action taken to solve the B/D Preventive action taken to avoid such breakdown in future 2.6 CATEGORY-WISE BREAKDOWN DURING THE MONTH DD-1 GEAR POWER SUPPLY OTHER CAUSES Major Minor Major Minor Major Minor No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur DD-News GEAR POWER SUPPLY OTHER CAUSES Major Minor Major Minor Major Minor No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur
8 2.7 CATEGORY-WISE PROGRESSIVE BREAKDOWN FROM APRIL OF CURRENT FINANCIAL YEAR DD-1 GEAR POWER SUPPLY OTHER CAUSES Major Minor Major Minor Major Minor No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur Nil Nil DD-News GEAR POWER SUPPLY OTHER CAUSES Major Minor Major Minor Major Minor No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur PERFORMANCE FIGURES OF VISUAL TRANSMITTER DD#1 DD#N Remarks Frequency of Vision MHZ MHz Carrier Frequency of Aural MHZ MHz Carrier K Factor (1) K-Bar 3% (2) K Pulse to Bar 3% (3) K2T 3% Less 2% Differential Gain - Less 5% Differential Phase - +/- 3 Signal to Noise Ratio - Less-60 db Vision Peak Power 9.0KW 20.0 KW 2.9 FREQUENCY RESPONSE OF VISUAL TRANSMITTER DD#1 Freq (MHz) Gain in db
9 DD#N PERFORMANCE FIGURES OF AURAL TRANSMITTER DD#1 DD#N Aural Carrier MHZ MHz Frequency response 1.2db 50 Hz to 15 KHz Distortion Factor 0.80% 0.30% F.M. Noise level -70 db -85 db Frequency Deviation at 100% Modulation 0 to+36 khz 2.11 PERFORMANCE OF ANTENNA SYSTEM Freq DD1 DD(N) DD1 DD(N) Lower Bay Upper Bay Combined Freq Lower Bay Upper Bay Combined Working Status of Dehydrator working is satisfactory. Dehydrator Working Status of working OK. Dehydrator 2.12 EARTH RESISTANCE (in Ohms) TX PS DG Set PDA-1 PDA-2 TOWER Date of Make, EARTH EARTH measure Model and ment type of Instrument used for measurem ent DD#1 To be & Digital
10 DD#N measur ed To be measure d WACO 1.3 & & Digital Waco 3. EQUIPMENTS & SPARES 3.1 REQUIREMENT OF SPARE COMPONENTS / CARDS DD#1 Name of Component / Card 28V/52 amp. SMPS supply Power Measurement Elements 25 & 100 watt Make-Bird Electronic Corp. Capacitor Fixed Ceramic 300 pf/10kv BEL 8F CX Valve Part No. Type-B1456 W Make-JSC Make-Bird Electronic Corp. Name of Unit of transmitt er for which required 10 KW Cavity 10 KW Cavity 10 KW Cavity 1 NO Qty Req, Qty availab le at Station Aural P.A. 02 No. 01 Nos. Thruline 01 Power each meter 10 KW Cavity Qty issued to Station during last six month 01 Justification for requirement NIL NIL Urgent requirement for power measurement 1 NO NIL NIL Failure of this capacitor service may be interrupted. 1 No. NIL NIL 08 no- Valves have duration more than 4000 hrs. 1 NO NIL Urgent need 200 PF/2KV Feed Through capacitor Transmitter 1 KW stage Exciter control unit R&S-Tx 01 Nil Nil No other Solution during failure P.A.Aural (VH602A27 R&S-Tx 01 Nil Nil -----do to 1 vision coupler xx R&S-Tx 02 Nil Nil -----do Relay-230 Volt 8 Pin Make- FINDER R&S-Tx 02 Nil Nil Optimod Unit Audio I/P 1 No. NIL NIL STANDBY USE DD#N Rach Hybrid Ampl HELA-10 P R & S 03 1 LDMOS-PTE R&S-Tx 04 Nil Nil -----do QQuick release R&S-Tx 06Set Nil Nil -----do Coupling System Male & QQuick release Coupling System R&S-Tx Female 06Set Male & Female Nil Nil -----do------
11 DD#N Rack Controller R&S-Tx 02 Nil Nil -----do Video Distribution GV8900(HS/V Input 01 Nil Nil Amplifier DA) Rack Programme Switcher VAMS Input 01 Nil Nil (Audio /Video) DBS-LCP Rack PUC Unit R&S 01 PUC power supply R&S 01 Power supply for R&S 01 aural PA Power supply for vision P.A. R&S 01 Resistance 250W/50 for R&S 25 combiner Pre-Amplifier R&S 01 IC L7812 R&S 01 Nil Nil Coolant pipe R&S 02 Nil Nil (front inlet to PA) 3.2 AVAILABILITY OF SPARE -- COMPONENTS / MODULES / TRANSMITTER UNITS Spare Components DD#1 DD#N Spare Transmitter Modules DD#1 Name of Spare Component Qty. in Stock Working Status 7f filament stack 2 nos 1-ok (1no-faulty) 20 mfd/3kv oil filled 01 no ok capacitor 4mfd/6kv oil filled 01 no ok cap. 0.1mfd/4kv oil filled 01no ok cap 0.1mfd/8kv oil filled 01no ok cap HT&BIAS 0 10nos ok resistances TVV100/150 01each ok transistor MOSFET BLF No. In Store Name of Spare Transmitter Modules (pallets) Qty. in stock Working Status DDA-5watt 01 ok 80 watt Vision amp. 01 ok BIT input -output 01 ok
12 RRB-MCS 01 OK CIB 01 OK RRB-BCS 01 OK IIB 01 OK BACK UP CONTOL 01 OK RELAY BOARD 01 OK DD#N CPU 01 OK CCU, Synthesiser, Modulator Assembly One Each 2 PUC- def No PUC in spare Spare Transmitter Units DD#1 Name of Spare Transmitter Unit 30 KVA, 3phase HT transformer Qty. in Stock 01 OK 11KVA, 3phase 01 ok Transformer 7F filament 01 ok transformer 8F filament 01 ok transformer 7F plate transformer 01 ok Working Status Screen grid 01 ok transformer DC bias power 01 ok supply 8F screen grid stack 01 ok DD#N UHF Ampl.(Vision) Two Def. Absorber resistance NIL - Preamplifier Board 5 Nos. Def. PUC unit 2Nos Def. P/S unit for Control & Motherboard Prt No Relay230V/2W 1No. 6Nos. Switching P/S for PUC 1No.
13 3.2 DETAILS OF DEFECTIVE TRANSMITTER EQUIPMENT Make & Model of Transmitter Name of defective Tx equipment Since when it is defective Action taken by Station for the repair Shortcoming if any, being faced by station for the repair Remarks DD # News R&S Make BEL Mark III DD#1 Exciter P/S module MPU-150 Powerone - 3nos. Sept08 Under repair Spare APA - Send to ADG(E) NZ workshop for repairing. PA VISION-2 nos. Feb.14 Under repair ATV Encoder Card of Exciter 200W AURAL PA June 13 & Sep.2014 JUNE do- Parts not available in mkt. R &S was approached to repair or to provide new one. Under repair Power supply needs repaired-02 nos. 50ohm/75ohm Transmission line 400w AURAL PA ohm/75ohm Transmission line 28volt/52amp SMPS 28volt / 50 amp Lambda power supply APL=2008 Mother board -burnt Technical pamphlets-not available One No. encoder card of exciter sent to zonal Office for repair. Un serviceable
14 On load changeover Switch Model No. IEC947-III make Havells (4pole,800A,415V,50Hz ) June 2011 Not available in Mkt due to obsolete Pl procure new model & modification is required in bus bars in the panel Urgently required in DD1 Chain : On load changeover switch Model No. IEC947-III Make Havells (4pole,800A,415V,50Hz ) Above C/o switch is defective & this model is not available due to old model. it is urgently required for DD National chain, On market survey available model 600/800A C/o switch need modification in the panel if installed. 3.3 WORKING STATUS OF AVR FOR TRANSMITTER S.No. Capacity of AVR Make and Type KVA for 20 KW R&S XTR 2 50KVA for 10 KW BEL XTR Automatic Electric Ltd., Model-LU- 216P Automatic Electric Ltd., Bombay, Model FT-350 Working Condition ( Auto/Manual/def) Ok Ok Action Taken for repair, if defective 3.4 TVRO ELECTRONICS S.No. Make & Type of IRDs Total No. available Total No. Defective Action taken Remarks by Station for repair Scopus IRD 04 2 partially def 2 Thomson 01 defective Mini Sky Nil Set Top Box- 02 Nil DTH 3.5 AIRCONDITIONERS & AVRs Total No. at Defective Nos. Make and Model of Date from Reason for Being Action taken
15 Air conditioner AVRs for ACs Station defective which defective 20 5 Voltas, Videocon, Amtrex Nayar,vintec Fimac,Cybex, Vigston, blue bird, Parker, V-Guard, Voltech, Uniline From Time to Time defective By Fluctuation by Station for the repair Action In hand PERFORMANCE OF AIR CONDITIONING UNIT 1. Equipments / Type / Make / Tonnage : (a) AMTREX Split Type 1.5TR - 1 Nos. S.Nos , 2. Location. : Transmitter Hall 3. Quantity. : 20Nos. 4. Out of Circuit : 04 Nos. (b) VOLTAS Split Type 2.0TR - 4Nos. (2 def) S.Nos. HR , HR , HR HR (c) CARRIER AIRCON Split Type 2.0 TR - 1 No. Model- 2TR 2BYO (d) VIDEOCON Split Type 2.0 TR - 3 Nos. (1def) Sl.No , , , e) Carrier-42KKL-024,Split type 2TR-3Nos Sl No , No...256, & Sl No f) Whirlpool 2T Split Ac type 2TR Model -2Nos. Model SAR24K40CSO, Sr.No.VK B6FJP15TSY0876, g) Samsung 1.5T window AC Model AW183WBETL-1No. S.no.A930PZLZ h) One repaired 1.5T window AC i) Voltas Split type 1.5T 2 No., Sr. No D12J001000, D
16 5. Tonnage Calculated : 2.0 TR ( AMTREX ), 7.0 TR ( VOLTAS ) 4 TR (VIDEOCON), 8TR(CARRIER) & 4TR( Whirlpool) 3T ( Window AC) 6. Important Work done (a) (b) (c) One repaired fan motor fitted in window AC unit. Filters and indoor units of all window and split AC were cleaned. Indoor unit of one split AC was cleaned to stop water leakage. 7. Performance : Good 8.. Action Taken for Repairs. : (1) One blower motor fan 2.0 T Carrier split AC unit is defective & needs its replacement. 3.7DETAILS OF DEFECTIVE INPUT / MONITORING AND MEASURING EQUIPMENTS S.No. Name of defective equipment Make and model of defective equipment Date from which defective 1 Power Meter Agilent EPM Series From Receiving Action taken by Station for the repairing Information already Through To ADG(NZ) 2 Side band analyzer Telemet 1999 Action to be taken after approval 3 DNL Meter Aplab 2007 Sn Audio analyzer is available 4 Audio limiter-2no Fab Requirement shown OPTIMOD 5 Stab amplifier TCSC-304A JULY-2008 Under maintenance 6 TV DEMODULATOR AMF-2 R&S 2005 Action to be taken after approval 3.8 DIESEL GENERATORS DD#1 DD#N (1) (1) Make RUSTON & HORNSBY, 6Y DA, Air Cooled Greaves AL-Series/6YDC MK-3
17 Capacity 62.5KVA 125 KVA 3- Phase Utilization for transmission during the month Test Hrs. for the month Total Working Hrs. for the month Avearge Per Liter 9.56 lt./hrs lt../hrs Occasion of utilization during the month Progressive Utilization Nos Progressive Utilization (Hrs) Breakdown in service due to failure of D/G during the month Average consumption of Diesel Total consumed in month 415 ltrs. Total consumed 640 ltrs. Date of commissioning of DG set Total Hours of working since hrs wef April date of commissioning Reading of Hour Meter installed Not working -- at DG Set at the end of month Reading of Hour Meter installed at LT Panel at the end of month -- Not Working Note : 1. Servicing of 62.5 KVA DG set was done. 2. In 125 KVA DG set, setting of fuel pump was done. One fuel pipe 24 and one broken fuel injector pipe was also changed.
18 DD-1 DD-News DD Regional DD Sports DD -Urdu DD RS Gyan Darshan DD Bharati (if not covered in Prime Band) 3. CABLE OPERATORS MONITORING REPORT MONITORING REPORT FOR THE IMPLEMENTATION OF CABLE TV NETWORK REGULATION ACT Zone : DDK Bareilly Month : SEPTEMBER 2014 S. N o. STATE & Name of Monitorin g Station Name and Address of MSOs DD CHANNELS TO BE CARRIED ON CABLE NETWORK Prime Band Non Prime Band Channels Channels REMARKS/ACTION TAKEN (Identifying defaulted MSOs, details about complaints lodged with law endorcing agencies etc.) 1. U.P. DDK Bareilly DEN ENTERTAINME NT NETWORK, 13-A, Model Town, Stadium Road, Bareilly (PIN ) Yes Yes Yes (DD Luckn ow) No Yes Yes Yes No M State wise report is to be compiled. All monitoring stations under the same state should come together. Cities and major locations need to be reported. 2. Statement YES or NO is to be mentioned against each channel both in prime and non prime band. 3. Action taken like reporting to DM/SP/any other law enforcing authority is to be mentioned in Remarks column. 4. Copy of complaint as lodged should be forwarded to the Satellite Maintenance Dte. Of DGDD DDE DDK Bareilly
PRASAR BHARTI (BROADCASTING CORPORATION OF INDIA) HPT DOORDARSHAN: BARMER. NO. HPT/BMR/Tech report/ / Dated:
PRASAR BHARTI (BROADCASTING CORPORATION OF INDIA) HPT DOORDARSHAN: BARMER Speed post NO. HPT/BMR/Tech report/201011/ Dated: 03.01.2011 The Chief Engineer (NZ) (Kind Attention:Sh. Aftab Ahmed, DE {DDM})
More informationPRASAR BHARATI (BROADCASTING CORPORATION OF INDIA) DOORDARSHAN MAINTENANCE CENTRE PATHANKOT. NO: DMC/PKT/3(2)/ /E DATE:
PRASAR BHARATI (BROADCASTING CORPORATION OF INDIA) DOORDARSHAN MAINTENANCE CENTRE PATHANKOT. NO: DMC/PKT/3(2)/2009-0/E DATE: 07..203 The Chief Engineer (NZ), (Kind Atten: Sh Sanjay Sethi DE-DDM), Akashvani
More informationizlkj Hkkjrh] Hkkjrh; izlkj.k fuxe] nwjn'kzu vuqj{k.k dsunz] vyeksm+k ¼mRrjk[k.M½& & bz- esy%
izlkj Hkkjrh] Hkkjrh; izlkj.k fuxe] nwjn'kzu vuqj{k.k dsunz] vyeksm+k ¼mRrjk[k.M½&263601 Qksu@QSDl% 05962&233103 bz- esy% dmcsealm@rediffmail.com i=kad%,,y,e@mh,elh@2¼1½@2012&13@bz&esy@ fnukad% 03&04&2013
More informationPRASAR BHARATI (BROADCASTING CORPORATION OF INDIA) CPC, DOORDARSHAN, NEW DELHI-49.
PRASAR BHARATI (BROADCASTING CORPORATION OF INDIA) CPC, DOORDARSHAN, NEW DELHI-49. No: 4(01) CPC/MR/2011/E Dated: 01.03.2012 To, The Director General Doordarshan, (Kind Attn: Shri Yuvraj Bajaj, ADG(E))
More informationELECTRIC GENERAL. MAINTENANCE MANUAL MHz, 35 WATT POWER AMPLIFIER ASSEMBLY 19D430488G1, 2 DESCRIPTION CIRCUIT ANALYSIS
MAINTENANCE MANUAL 851-870 MHz, 35 WATT POWER AMPLIFIER ASSEMBLY 19D430488G1, 2 DESCRIPTION The power amplifier assembly for MASTR II uses six RF power transistors to provide a maximum of 35 Watts output
More informationPCN-1800 Series. VHF TV Transmitter. 2nd Edition
PCN-1800 Series VHF TV Transmitter 2nd Edition The Benchmark in Analog TV Broadcasting Compact design and innovative technology establish NEC s new transmitter as the new benchmark in analog TV transmitters.
More informationLBI-4938C. Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3. Printed in U.S.A. Maintenance Manual
C Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3 Printed in U.S.A. Maintenance Manual TABLE OF CONTENTS DESCRIPTION.................................................... 1 CIRCUIT ANALYSIS.................................................
More informationAVL-10000T AUDIO VIDEO LINK TRANSMITTER TECHNICAL MANUAL
AVL-10000T AUDIO VIDEO LINK TRANSMITTER TECHNICAL MANUAL Document : AVL-10000T Version: 1.00 Author: Henry S Date: 25 July 2008 This module contains protection circuitry to guard against damage due to
More informationHigh Frequency Communication in Antarctica
Anant Kumar Andhare Bharat Electronics Limited ABSTRACT Three kinds of communication equipment were used by the Second Indian expedition team dur ing their stay at Antarctic. These were High power HF transmitter
More informationA 500 Broadband Power Amplifier
A 500 Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with
More informationMAINTENANCE MANUAL TRANSMITTER/RECEIVER BOARD CMN-234A/B FOR MLSU141 & MLSU241 UHF MOBILE RADIO TABLE OF CONTENTS
MAINTENANCE MANUAL TRANSMITTER/RECEIVER BOARD CMN-234A/B FOR MLSU141 & MLSU241 UHF MOBILE RADIO TABLE OF CONTENTS DESCRIPTION... 2 CIRCUIT ANALYSIS... 2 TRANSMITTER... 2 9-Voft Regulator... 2 Exciter...
More informationizlkj Hkkjrh Hkkjrh; izlkj.k fuxe] nwjn'kzu dsunz] fglkj
izlkj Hkkjrh Hkkjrh; izlkj.k fuxe] nwjn'kzu dsunz] fglkj ØEkkad% MhMhds@,p,lvkj@5@2009-10@bZ fnukad 07-02-13 vij egkfuns kd vfhk;a=.k(¼mrjh{ks=½ uker% ¼Jh okbz ds flg mi egkfuns kd vfhk;a+=.k]½ vkdk kok.kh,oa
More information10-SERIES FM RADIO AMPLIFIERS & TRANSMITTERS SILICON VALLEY POWER AMPLIFIERS
10-SERIES FM RADIO AMPLIFIERS & TRANSMITTERS SILICON VALLEY POWER AMPLIFIERS SVPA FM Radio Catalog Page 1 SILICON VALLEY POWER AMPLIFIERS began in 1990 building solid state amplifier communications modules.
More information1140LA Broadband Power Amplifier
1140LA Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with
More informationContinental's 816R -5B, 35 kw Single Tube Broadcast Transmitter. Includes the 802A solid -state exciter
Continental's 816R -5B, 35 kw Single Tube Broadcast Transmitter Includes the 802A solid -state exciter LED status indicators Features SCR Power Control Automatic RF Power Output Control Automatic SWR Circuit
More informationATV Modulator User Manual
ATV Modulator User Manual FMTV Modulator by Grant ZL1WTT & Keith ZL1BQE 20 February 2004 Page 1 Display board layout The controller consists of a 2x 16 LCD display with three push buttons and a rotary
More informationSolid State General Communication Power Amplifier
The GCS1D2GUT (SKU 4062) is suitable for broadband high power linear applications in the HF frequency range. This rack mount amplifier utilizes pushpull MOSFET power devices that provide high gain, wide
More information3100LA Broadband Power Amplifier
3100LA Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with
More informationMT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER
ISO 9001 MODEL MT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER MT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER FOR SATELLITE FOR SATELLITE UPLINK UPLINK APPLICATIONS C-BAND: 400W X-BAND: 400W Ku-BAND:
More information1 KW TOTALLY SOLID STATE DIFFERENTIAL GPS TRANSMITTER ( khz)
GPS1000 1 KW TOTALLY SOLID STATE DIFFERENTIAL GPS TRANSMITTER (282-326 khz) NAUTEL has developed the GPS1000 as an extremely efficient and highly reliable transmitter especially suited for use at remote
More information1. SYSTEM DESCRIPTION NON - DIRECTIONAL RADIO BEACON TRANSMITTER (NDB) JTM-30C
Documentation Rev.Date Rev. Document no. 1. SYSTEM DESCRIPTION NON - DIRECTIONAL RADIO BEACON TRANSMITTER (NDB) JTM-30C 1. SYSTEM DESCRIPTION... 2 1.1 OVERALL SYSTEM DESCRIPTION... 2 1.2 BASIC MODULES...
More informationMODERN AM BROADCAST STATIONS
MODERN AM BROADCAST STATIONS With DDS DDS EXCITER OPERATING MANUAL 75w carrier - 300w p.e.p What is DDS IT IS THE INITIALS OF THE WORDS DIRECT DIGITAL SYNTHESIZER, THAT MEANS: DIRECT DIGITAL FREQUENCY
More informationCX7 Troubleshooting Index
CX7 Troubleshooting Index Modification S/1 Newsletter Guide Board Description A/TO A/TO MODE Intermod V1,12 P4.4 A11 Shut off one 35 MHz osc in receive, done sn 244 A/TO Spur V1,12 P1 Reduce A/TO spur,
More informationGOVERNMENT OF KARNATAKA KARNATAKA STATE PRE-UNIVERSITY EDUCATION EXAMINATION BOARD II YEAR PUC EXAMINATION MARCH-2013 SCHEME OF VALUATION
GOVERNMENT OF KARNATAKA KARNATAKA STATE PRE-UNIVERSITY EDUCATION EXAMINATION BOARD II YEAR PUC EXAMINATION MARCH-03 SCHEME OF VALUATION Subject Code: 0 Subject: PART - A 0. What does the arrow mark indicate
More informationFM TRANSMITTERS TESTS
FM TRANSMITTERS TESTS - FACTORY TESTS - SITE TESTS Page 1 of 11 I. FACTORY TEST (on dummy load) TX s.n... Exciter no...(s.n...) Date... Page 2 of 11 1.PERFORMANCE A) OPERATING FREQUENCY Carrier stability:
More informationSPECIFICATIONS: Subcarrier Frequency 5.5MHz adjustable, FM Modulated +/- 50KHz. 2nd 11MHz >40dB down from 5.5MHz
Mini-kits AUDIO / SUBCARRIER KIT EME75 Version4 SPECIFICATIONS: Subcarrier Frequency 5.5MHz adjustable, FM Modulated +/- 50KHz Subcarrier Output 1.5v p-p Output @ 5.5MHz DESCRIPTION & FEATURES: The Notes
More informationInstruction Manual OM3500 HF SHORTWAVE POWER AMPLIFIER. OM POWER, s. r. o Bác 126 SLOVAKIA
Instruction Manual OM3500 HF SHORTWAVE POWER AMPLIFIER OM POWER, s. r. o. 930 30 Bác 126 SLOVAKIA Important safety instructions: The amplifier contains high voltage circuits. Never turn the amplifier on
More information5/1.0 kw AM Transmitter
5/1.0 kw AM Transmitter Collins' 820E /F -1 series of broadcast transmitters is one of the most extensively transistorized series of transmitters available in the 5 -kw to 10 -kw power range. The series
More informationCOLLINS 20T 1000/500 WATT AM BROADCAST TRANSMITTER
COLLINS 20T 1000/500 WATT AM BROADCAST TRANSMITTER TJIee COLLINS 20T 1 0 0 0 / 5 0 0 W A T T AM BROADCAST TRANSMITTER high fidelity performance low no a and di-tortion vertical chassis construction recycling
More informationXR kw AM Medium Wave Broadcast Transmitter
XR12 12 kw AM Medium Wave Broadcast Transmitter XR12 12 kw AM Medium Wave Broadcast Transmitter XR Series Power Module POWERFUL BUILDING BLOCKS The building block for the XR12 is a power module integrating
More informationMODERN AM BROADCAST STATIONS AM STEREO CQUAM WITH DDS
MODERN AM BROADCAST STATIONS AM STEREO CQUAM WITH DDS DDS EXCITER OPERATING MANUAL 20W CARRIER - 80W PEP WHAT IS DDS? IT IS THE INITIALS OF THE WORDS DIRECT DIGITAL SYNTHESIZER. THAT MEANS: DIRECT DIGITAL
More informationENGINEERING DATA SUBMITTAL For the Interconnection of Generation System
WHO SHOULD FILE THIS SUBMITTAL: Anyone in the final stages of interconnecting a Generation System with Nodak Electric Cooperative, Inc. This submittal shall be completed and provided to Nodak Electric
More informationT800 Series II Conventional Equipment. Reference Guide M800RACK
T800 Series II Conventional Equipment Reference Guide M800RACK-00-00 M800RACK-00-00 Index Section : Section : Section : Section 4: Section 5: Section 6: Section 7: Section 8: Introduction Guide to the
More informationTELEVISION TRANSMITTERS
TELEVISION TRANSMITTERS 1KW - 50KW High Efficiency UHF L.D.M.O.S SUPER LINEAR CAN BE UPGRADED TO DIGITAL BY CHANGING MODULATOR/EXCITER The prices are subject to change.please request a written quotation
More informationMaintenance Manual. MTD SERIES 900 MHz, 10-WATT, DATA ONLY MOBILE RADIO. Mobile Communications LBI TABLE OF CONTENTS
Mobile Communications MTD SERIES 900 MHz, 10-WATT, DATA ONLY MOBILE RADIO TABLE OF CONTENTS RF BOARD............................... LBI-38545 AUDIO BOARD............................ LBI-38546 LOGIC BOARD............................
More informationAmateur Radio Examination EXAMINATION PAPER No. 275 MARKER S COPY
01-6-(d) An Amateur Station is quoted in the regulations as a station: a for training new radio operators b using amateur equipment for commercial purposes c for public emergency purposes d in the Amateur
More informationTX5KPS - TX10KPS 5 and 10 KW Hot-Pluggable version
TX5KPS - 5 and 10 KW Hot-Pluggable version FM Solid State Power Amplifier 87.5-108 MHz range Built-in RF power combiner and splitter. Each power amplifier module has its own with switching power supply.
More informationSOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1
1-1 1 Introduction The SE Series transmitters are computer controlled systems designed around an embedded microprocessor. These systems are capable of remote monitoring and maintenance via Ethernet (optional).
More informationUltra 4B SE Special Edition. Stereo Phono/Line Preamplifier
Modular Series Ultra B SE Special Edition Stereo Phono/Line Preamplifier User s Manual Phono Line Line Balance Volume Mapletree Audio Design Ultra B SE Stereo Preamplifier Rev. Feb. / Mapletree Audio Design
More informationLOI Progress Report -- Summary of Experiment in January
LOI Progress Report -- Summary of Experiment in January 2010 -- LOI-7 February 18, 2010 1. Introduction Following the previous experiments in October, 2009, a new method to improve the RF waveform distortions
More informationNA100 NA200 NA300. NA Series Frequency Agile Medium Wave Broadcast Transmitters
NA100 NA200 NA300 NA Series Frequency Agile Medium Wave Broadcast Transmitters Making Digital Radio Work. Nautel NA100, NA200 & NA300 Quick Specs Field tunable to any frequency in the medium wave band
More information2100L Broadband Power Amplifier
2100L Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with
More informationMaintenance Manual TRANSMITTER/RECEIVER BOARD CMN-233 FOR MLSH041
Maintenance Manual TRANSMITTER/RECEIVER BOARD CMN-233 FOR MLSH041 TABLE OF CONTENTS Page DESCRIPTION... 2 CIRCUIT ANALYSIS... 2 Transmitter... 2 9-volt Regulator... 2 Exciter... 2 40-Watt PA... 2 Antenna
More information5kW TECH NOTE. Maximizing Transmitter Efficiency: A Study of the Ecreso FM 5kW.
5kW Maximizing Transmitter Efficiency: A Study of the Ecreso FM 5kW www.worldcastsystems.com Efficiency is one of the most important criterion when choosing a new FM Transmitter for your network. Given
More informationFEATURES: Reduced Depth. Output RF Power Hold. Easily Accessible Diagnostic Port. Programmable Alarms. Event And Maintenance Logs. Ethernet Interface
MT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER FOR SATELLITE UPLINK APPLICATIONS C-BAND: 400W X-BAND: 400W Ku-BAND: 400W DBS-BAND: 270W DUAL C-/Ku-BAND: 325W DUAL Ku-/DBS-BAND: 350W AVAILABLE SYSTEM
More informationSUPPLY OF CARRIER PROTECTION COUPLER TYPE NSD-50
(I) GENERAL : Indoor PLCC Equipments are required for important 400KV, 220KV and 132KV Sub/station for Speech, Data Transmission, Protection and Teleprinter Links. (II) GENERAL REQUIREMENT : The equipments
More informationProduct Catalog Spring 2017 AmericanAmpTech.com
Innovative Ideas, Quality Products, Competitive Prices Product Catalog Spring 2017 AmericanAmpTech.com TABLE OF CONTENTS... 3 FM Transmitters & Amplifiers... 4 IPA Modules... 6 FM Bandpass Filters... 7
More informationInstallation & Operation Manual SAGA1-K Series Industrial Radio Remote Control
Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Gain Electronic Co. Ltd. Table Of Contents Safety Considerations ------------------------------------------------------------2
More informationN. TEST TEST DESCRIPTION
Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities
More informationMASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2. Maintenance Manual LBI-30766L. Mobile Communications
L Mobile Communications MASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2 Printed in U.S.A Maintenance Manual TABLE OF CONTENTS Page SPECIFICATIONS.....................................................
More informationThe ETO-Alpha 89 ETO-Alpha 89
ETO-Alpha 89 The 89 was produced from 12/92 to 9/2000, 408 units were built during this time. These units were much like the 86, but with many updates and refinements. The 89 uses a pair of 3CX800A7 triodes
More informationFREQUENCY AGILE FM MODULATOR INSTRUCTION BOOK IB
FMT615C FREQUENCY AGILE FM MODULATOR INSTRUCTION BOOK IB1215-02 TABLE OF CONTENTS SECTION SUBJECT 1.0 Introduction 2.0 Installation & Operating Instructions 3.0 Specification 4.0 Functional Description
More informationLBI-31564A. Mobile Communications. DELTA - SX MHz RADIO COMBINATIONS (NEGATIVE GROUND ONLY) Maintenance Manual
A Mobile Communications DELTA - SX 136-174 MHz RADIO COMBINATIONS (NEGATIVE GROUND ONLY) Maintenance Manual TABLE OF CONTENTS MILITARY AND SYSTEM SPECIFICATIONS................................. 2-3 COMBINATION
More informationSafety Information (Attach ed at the upper cover of t his product) Safety Warning (Attached on the output fiber isolato r & collimator) Figure 1 Laser
Safety Please read this user manual carefully before operating the YDFLP fiber laser. It provides essential information regarding safety, product operation, and other necessary reference information. For
More informationHLV Instruction & Operations Manual. Content
HLV-800-3 Instruction & Operations Manual Content 1 Chapter page 1. Certificate of conformity 3 2. Introduction 4 3. Safety instructions 5 4. Electrical connections 6 5. Warranty 7 6. Front panel operation
More informationT-link8. SPLITTER/MIXER T-link8. T-link8
SPLITTER/MIXER CH CH CH CH CH CH Technical Specifications AUDIO INPUTS AUDIO OUTPUTS SYSTEM SPECIFICATIONS FUNCTION CONTROLS FUNCTION SWITCHES INDICATORS POWER SUPPLY PHYSICAL Connectors Type Impedance
More informationWILCOX 914A RF modules kb
Local Oscillator 0 50 0. MHz uf A T V dc / A Power Supply R0 R0 0 0 k n 0 00uH V 00 L0 0 +.V k N 0 0-0mV +0 V x N 55V 0 0 k 50mA MHz n 5 50 5k C 5 0 ON/OFF 0 MC IF AMPLIFIER n RFC p C0 W N05 STC50 5-0
More informationMSE M A G N E T I C S O U N D E N H A C E R. Passion
Passion for F M &T V Broadcasting MOZART Series Green RF tecnology High Efficiency 120W to 5000W Compact and Modular FM Transmitters Tr MSE M A G N E T I C S O U N D E N H A C E R TECHNICAL CHARACTERISTICS
More informationPowerAmp Design. PowerAmp Design PAD01 COMPACT POWER OP AMP
PowerAmp Design COMPACT POWER OP AMP Rev C KEY FEATURES LOW COST HIGH VOLTAGE 00 VOLTS HIGH OUTPUURRENT 5A 30 WATT DISSIPATION CAPABILITY 50 WATT OUTPUAPABILITY SMALL FOOTPRINT 30mm SQUARE RoHS COMPLIANT
More informationDECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY Manufacturer's Name: Transmille Ltd. Manufacturer's Address: Unit 4, Select Business Centre Lodge Road Staplehurst TN12 0QW. United Kingdom. Declares, that the product Product
More informationO W N E R S M A N U A L. Po w e r A m p l i f i e r s
O W N E R S M A N U A L Po w e r A m p l i f i e r s 1.0 Equipment installation Normally your Naim equipment will have been installed by the dealer who sold it to you even if you live outside their immediate
More informationState of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company
Engineering data submittal Page 1 WHO SHOULD FILE THIS SUBMITTAL : Anyone in the final stages of in terconnecting a Generation System with Otter Tail Power. This submittal shall be completed and provided
More information1 FUNCTIONAL DESCRIPTION WAY SPLITTER/INPUT BOARD FET RF AMPLIFIERS WAY POWER COMBINER VSWR CONTROL BOARD...
CONTENTS 1 FUNCTIONAL DESCRIPTION...1 2 4-WAY SPLITTER/INPUT BOARD...2 3 FET RF AMPLIFIERS...3 4 4-WAY POWER COMBINER...4 5 VSWR CONTROL BOARD...5 6 ADJUSTMENT OF BIAS VOLTAGE TO ESTABLISH PROPER QUIESCENT
More informationMX800 BASE STATION SPECIFICATIONS
MX800 BASE STATION SPECIFICATIONS Minimum performance to exceed the following for 30MHz to 960MHz*: Conforms but not all bands approved. GENERAL Frequency Range: AS4295-1995, R&TTE EC Directive 1995/05/EC,
More information1. COMMUNICATION 10. COMMUNICATION SYSTEMS GIST The sending and receiving of message from one place to another is called communication. Two important forms of communication systems are (i) Analog and (ii)
More informationHLV Instruction & Operations Manual
HLV-2000 Instruction & Operations Manual 1 Content Chapter page 1. Certificate of conformity 3 2. Introduction 4 3. Safety instructions 5 4. Electrical connections 6 5. Warranty 7 6. Front panel operation
More informationPower supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation
Portable Description Features Measures all of the main electrical parameters of an electricity network Measurement in true root mean square Built-in energy meter With 4 voltage channels and 4 current channels
More informationA 075 Broadband Power Amplifier
A 075 Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with
More informationA Series Professional Power Amplifiers
Minimum 4 ohm A500 A700v A750 A1000 A1004 A1500 Q6 Q1004 QB1000/600 USER MANUAL A Series Professional Power Amplifiers www.datasheet4u.com Minimum ohm A000 A3000 A0 A5000 A5003 A6000 Q900 www.datasheet4u.com
More informationThe New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived
GaN MAX The New Standard in High Redundant Microwave Amplifier Systems Has Arrived FEATURES Gallium Nitride amplifiers, offering better power over frequency Output levels of up to: 10 kw in S-, C- and
More informationHLV-350. Instruction & Operations Manual
HLV-350 Instruction & Operations Manual 1 Content Chapter page 1. Certificate of conformity 3 2. Introduction 4 3. Safety instructions 5 4. Electrical connections 6 5. Warranty 7 6. Front panel operation
More informationHFCC 2018 Bratislava Product Launch: Low Power Solid-State Shortwave
HFCC 2018 Bratislava Product Launch: Low Power Solid-State Shortwave 27.08.2018 1 Our Mission Science MedTech Ampegon designs and delivers high power systems for world-class research facilities. «We offer
More informationCOMMUNICATION SYSTEMS
COMMUNICATION SYSTEMS 1. A cordless telephone using separate frequencies for transmission in base and portable units is known as A. duplex arrangement B. half duplex arrangement C. either (a) or (b) D.
More information2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.
1.0 Scope This document describes the specification for Toshiba 1000 Series On-Line Uninterruptible Power System (UPS). The UPS will supply a computer grade AC output sine wave which is unaffected by the
More informationOscilloscope Probes and Accessories
Oscilloscope Probes and Accessories Pomona s oscilloscope probes give you the full range you need. Designed, rated, and specified to match the bandwidth of your instrument, they provide you with full voltage
More information8792 Power Tube. Linear Beam Power Amplifier Tube
8792 Power Tube Linear Beam Power Amplifier Tube 1000 Watts Peak Sync Output in VHF Translator Service 265 Watt Average-Noise-Power Output with White Noise Loading 300 Watt Power Output in UHF-Linear Telephony
More informationExternal sources of RFI at the GMRT: Methods for control and co-existence with commercial users
External sources of RFI at the GMRT: Methods for control and co-existence with commercial users Pravin Ashok Raybole 1 GMRT-NCRA-TIFR P.O Box No. 6, Narayangon, Pune, India. E-mail: pravin@gmrt.ncra.tifr.res.in
More informationSCHEDULE OF WORK. Balmer Lawrie Co. Ltd. PRICED BID (PART-II) MMLH
SCHEDULE OF WORK Supply, Installation, Testing & Commissioning (SITC) of 33KV Electrical Substation for Multi Modal Logistics Hub at Visakhapatnam, Andhra Pradesh. Tender No. MMLH /HTELEC/PT /18 dated
More informationTELEMETRY RE-RADIATION SYSTEM
TELEMETRY RE-RADIATION SYSTEM Paul Cook, Director, Missile Systems Teletronics Technology Corporation, Newtown, PA USA Louis Natale, F-22 Instrumentation Sr. Staff Engineer Lockheed Martin Aeronautics
More informationMAINTENANCE MANUAL RF BOARD 19D901835G1 ( MHz) 19D901835G2 ( MHz) FOR MVS
D MAINTENANCE MANUAL F BOAD 19D901835G1 (136-153 MHz) 19D901835G2 (150-174 MHz) FO MVS TABLE OF CONTENTS DESCIPTION............................................... Front Cover CICUIT ANALYSIS..............................................
More informationCHALLENGER II HF LINEAR AMPLIFIER
CHALLENGER II HF LINEAR AMPLIFIER (GS 35 Model) Operating Manual WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D-76863 Herxheim Tel. (07276) 96680 FAX 6978 http://www.wimo.com e-mail: info@wimo.com
More informationParallel AMX AC Power Systems
Parallel AMX AC Power Systems 8kVA to 30kVA 20-5,000 Hz 1Ø4 0-338VL-N 2Ø4 0-600V L-L 4 0-338V L-N /585V L-L Standard Features: Master/Slave Operation of 2 to 5 AMX AC s provides AC Power Levels to from
More informationCBA 400M MHZ to 400 MHZ
1 CBA 400M-100 1 MHZ to 400 MHZ 100 watt amplifier user Manual 601-298A CBA 400M-100 1 MHZ to 400 MHZ 100 watt amplifier USER Manual CBA 400M-100 User Manual contents 1 Safety information 5 2 Introduction
More informationDOORDARSHAN KENDRA : CHANDIGARH. Details of Scheduled Programme Hrs. for the Month of February O/C Hrs. Gear Hrs.
1 DOORDARSHAN KENDRA : CHANDIGARH Details of Scheduled Programme Hrs. for the Month of February - 2010 Sr. No. Name of the Station Schedule Prog. Hrs. Gear Hrs. O/C Hrs. Breakdown Details Power Supply
More information8791 Power Tube. Linear Beam Power Amplifier Tube
8791 Power Tube Linear Beam Power Amplifier Tube Ruggedized, Reliable 80 Watt Average-Noise-Power Output with White Noise Loading 250 Watt Power Output in VHF-Linear Translator Service 500 Watt PEP Output
More informationMoveable Probe Thick Silver Plated
Coarse Tuning Rod Fine Tuning Rod Loop Assembly 1/4 Thick Cavity Top 0.12 Thick Cavity Shell Finish: Gold Iridite Stationary Probe 0.055 Wall Silver Plated Moveable Probe 0.031 Thick Silver Plated Bandpass
More informationPLUG N PLAY WATT DIGITAL FM TRANSMITTER. April, 2002 IM No
PLUG N PLAY 1000 1000 WATT DIGITAL FM TRANSMITTER April, 2002 IM No. 597 9972 OPERATION/FEATURE PROGRAMMING. The PNP 1000 allows the user to select many types of different operating parameters and features.
More informationPower Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report
PSL Standards Lab 980 Atlantic Avenue Alameda, CA 94501 USA TEL ++1-510-522-4400 FAX ++1-510-522-4455 www.standards.com Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report IEC 62053-22
More informationIndustrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America
World-Wide 3-phase Input Voltage Range (nom. 200 Vrms to 480 Vrms), PF > 0.94 High Power Density 16 W/in 3 94% Typical Efficiency Parallel Operation up to 16 Units (50.4 kw) Cold-Plate Cooling System -25
More informationDante. Dante Network Class D Professional Audio Amplifier D-3000
Dante TM Dante Network Class D Professional Audio Amplifier D-3000 SUMMARY The D-3000 is a high power professional amplifier specially designed for the sound re-enforcement market also referred to as SR,
More informationMHz 58 db 1 KW RF Amplifier (EDA 00097)
EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN A&B DEPARTMENT AB-Note-2004-029 RF 0.2-10 58 1 KW RF Amplifier (EDA 00097) M. Paoluzzi 25 th March 2004 Geneva, Switzerland 1 1. DESCRIPTION 1.1. GENERAL
More informationFM W STEREO TRANSMITTER/EXCITER TECHNICAL MANUAL
FM-100 100W STEREO TRANSMITTER/EXCITER TECHNICAL MANUAL LARCAN Denver Office (LARCAN-USA) 1390 Overlook Drive #2, Lafayette, CO 80026 USA Tel: 303-665-8000 Fax: 303-673-9900 E-Mail: sales@earthnet.net
More informationBasic Harris DX Transmitter Tutorial
BASIC DX TUTORIAL Basic Harris DX Transmitter Tutorial Basic DX Theory The Harris DX Transmitters series, introduced in 1986, have proven to be the most efficient method of Amplitude Modulation at medium
More informationFM/HD Radio Efficiency Improvement
SBE Chapter 39 Broadcast Technology Symposium Tampa, FL Nov 13, 2014 FM/HD Radio Efficiency Improvement Gary Liebisch Eastern Regional Sales Manager NAUTEL 1 Agenda Efficiency Definitions Short history
More informationAn RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.
The TCP3500 series is an AC-DC converter with adjustable DC output and universal 3-phase AC input. Conduction cooling (No Fans) makes this power supply series suitable for a wide variety of Industrial
More informationPART 1 OWNER/APPLICANT INFORMATION
CALHOUN COUNTY ELECTRIC COOP. ASSN. Application for Operation of Customer-Owned Generation This application should be completed as soon as possible and returned to the Cooperative in order to begin processing
More informationThe New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived
GaN MAX The New Standard in High Redundant Microwave Amplifier Systems Has Arrived FEATURES Gallium Nitride amplifiers, offering better power over frequency Output levels of up to: 10 kw in S-, C- and
More informationConstruction notes for the symmetrical 400 watt amplifier
Construction notes for the symmetrical 400 watt amplifier Introduction The symmetrical amplifier is an update of one of my designs, which appeared in the Australian electronics magazine Silicon Chip in
More informationPA FAN PLATE ASSEMBLY 188D6127G1 SYMBOL PART NO. DESCRIPTION. 4 SBS /10 Spring nut. 5 19A702339P510 Screw, thread forming, flat head.
MAINTENANCE MANUAL 851-870 MHz, 110 WATT POWER AMPLIFIER 19D902797G5 TABLE OF CONTENTS Page DESCRIPTION.............................................. Front Page SPECIFICATIONS.................................................
More informationPQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.
General PQ: Power Quality has multiple issues involved. Thus, need to have some benchmarking standards. Very little is spoken about the LT supply installation within an industry. There is need to understand
More information