T800 Series II Conventional Equipment. Reference Guide M800RACK
|
|
- Archibald Barber
- 5 years ago
- Views:
Transcription
1 T800 Series II Conventional Equipment Reference Guide M800RACK-00-00
2 M800RACK Index Section : Section : Section : Section 4: Section 5: Section 6: Section 7: Section 8: Introduction Guide to the Conventional T800 Equipment Questionnaire Conventional T800 Equipment Questionnaire Order Number System Rack and Function Cross-Reference Chart Rack Components Weights Rack Configurations Rack Options Guide Assemblies Rack Backplanes Personality Boards Ancillary Modules Modules Copyright TEL 0/8/99
3 T800 Series II Conventional Equipment Reference Guide Introduction
4 M800RACK Section T800 Conventional Equipment This publication contains relevant reference information for Tait s T800 Conventional product range. It will be updated as equipment is modified or new features are introduced. It is intended to show only standard options. There is provision to mix & match up to seven modules in a rack to produce combinations for customised solutions. Tait System Solutions are open-ended. As well as information about the equipment there is also an order form and detailed instructions on how to fill in the order form. If you cannot find a solution, Please contact RSD Custom Solutions. Contact Details Chris Quinlivan Alex Brunton Alana Mehrtens Conventional Systems Manager Systems Consultant Technical Illustrator 55 Wairakei Rd PO Box 645 Christchurch New Zealand Telephone: (64) () 5899 Facsimile: (64) () conventional.system@tait.co.nz Copyright TEL 0/8/99
5 M800RACK Section Document Control The initial release of this guide will be a hard copy delivered to Customer Service Organisations and other relevant people within the Tait organisation. In the interests of improving the performance, reliability or servicing of the equipment, Tait Electronics Limited reserve the right to update the equipment or this document or both without prior notice. The Master copy will be available on the Tait Electronics Ltd Customer Service web site. Changes will be notified to all document holders who will be responsible for updating these changes from the web site. Copyright TEL 0/8/99
6 Guide and Purpose of Filling out Conventional T800 Equipment Questionnaire The purpose of this questionnaire is to assist the staff of RSD to get as much information as possible from you at the start of your enquires or order request for equipment that is to be SET-UP BY RSD. The accurate completion of this form will speed up processing time and ensure delivery of the correct equipment. PART 0. (WHAT IS REQUIRED) This is to immediately identify the quantity and what sort of configuration or equipment is required. PART 0. (FREQUENCY BAND REQUIRED This is to indicate which frequency band the equipment is required to operate in. It also gives the equipment type required.( for Series I the last four digits are not needed). In some cases there will be a need for Transmitter and to be in different bands; this will not affect the Rackframe required. ENSURE EQUIPMENT STATED IS TYPE APPROVED FOR COUNTRY OF USE. PART 0. (DO YOU KNOW WHAT IS REQUIRED) The completion of this section in full is not always essential but the more information you provide will assist the Technician in correctly configuring the Rackframe to your requirements. SPEAKER PANELS ARE FITTED AS STANDARD WHERE APPROPIATE In the Rackframe line for part number you may put the code for the configuration required, these codes can be found in the T800 Series II Conventional Equipment Reference Guide, Section. If you do not have an RSD code, you may enter either the high T number, if known. These are also in the Reference Guide, Section, or enter do not know and leave the selection of Rackframe to RSD who will select the appropriate configured Rackframe to meet your requirements, based on the rest of the information provided in this section. T800questV6.doc : Issued 5 Aug 999 Page of
7 For the rest of the requirements you may tick the appropriate YES box for the module that you would like to be fitted into the Rackframe, remembering there is only sufficient room to fit 7 x 60mm modules. Doing this will help RSD ensure that if a Rackframe has been mentioned it can support your requirements. If no standard Rackframe exists that will fulfil your needs, then RSD will engineer a configuration to satisfy your requirements. PART 04 (EQUIPMENT TYPE REQUIRED) This is to indicate the preferred type of equipment you require, remembering that eventually all types will be Series II. Ensure type ordered are Type Approved for Country of use. PART 05 (DO YOU KNOW THE FREQUENCIES) This information can be helpful as sometimes the auxiliary equipment can be frequency dependant, ie; Duplexer/Splitters, etc.. PART 06 (AUXILLIARY EQUIPMENT) The information provided in this section ensures that the auxiliary equipment asked for is appropriate for the frequency band that the rest of the equipment is to operate in. PART 07 (ANCILLIARY EQUIPMENT) This section is to advise RSD of the maintenance support equipment required. PART 08 (BRIEF DESCRIPTION) This section is to enable you to give RSD a quick operational requirement and provide sketches if deemed necessary on the information sheet provided. PART 09 (ADDITIONAL COMMENTS) This section is to allow you to provide any extra information you think RSD will require. T800questV6.doc : Issued 5 Aug 999 Page of
8 PART 0 This is to inform RSD of your required delivery DATE. PART (TRANSMITTER/EXCITER PARAMETERS) This section is to allow you to inform RSD of operational parameters for the equipment. By ticking the STANDARD box you are indicating that all parameters required are as stated in the Set-up procedure in the appropriate equipment manual, and the frequency/frequencies required are as stated in PART 05. If no frequencies are stated in Part 05 then the equipment is to be Set-up on TEST frequencies. By ticking the CUSTOMISED box you are indicating special requirements are needed. You must then fill in all the required details in the boxes below to allow RSD to set-up the equipment to those specifications and options, and to supply any other information that may be required by RSD. PART (RECEIVER PARAMETERS) Same as above. T800questV6.doc : Issued 5 Aug 999 Page of
9 CONVENTIONAL T800 EQUIPMENT Customer Information: Date: Customer / C.S.O From: Purchase Order Number: RSD Quote Reference: RSD Staff Responsible: This form has been devised to assist in clearly identifying the Product required, and its operational parameters if being BUILT and TESTED by RSD. DO YOU REQUIRE RACKS and MODULES? DO YOU REQUIRE MODULES ONLY? (Please continue on this page) (RSD to Set-up, Please go to PART 04) PART 0. WHAT IS REQUIRED? Base Station Portable Slimline To Operate as a Repeater Yes No TOTAL QUANTITY REQUIRED :- PART 0. FREQUENCY BAND REQUIRED? 66-88Mhz (T8n-xx-xxxx) 0-44Mhz (T86n-xx-xxxx) Mhz (T85n-xx-xxxx) 6-56Mhz T8n-xx-xxxx) 4-70Mhz (T86n-xx-xxxx) Mhz (T85n-xx-xxxx) 48-74Mhz (T8n-xx-xxxx) 0-80Mhz (T87n-xx-xxxx) Mhz (T88n-xx-xxxx) 74-5Mhz (T7n-xx ) Mhz (T85n-xx-xxxx) Mhz (T88n-xx-xxxx) ARE REQUIRED MODULES TYPE APPROVED, COUNTRY OF USE :- PART 0. DO YOU KNOW WHAT IS REQUIRED PER RACK? Description Option Required Qty Part Number Rackframe Transmitter Exciter Amplifier 50 Watts 70 / 00 Watts AC for Volts External.8V Battery Converter /, 4/, 48/ Circuit Breaker 0Amp, 0Amp or 0Amp Alarm Unit Unit Tone Remote Combiner 00W Hi Stability Osc Channel Panel 0 Channel / 00 Channel Cooling Fan Single or Double Relay-50 W Max Duplexer Tx/Rx Frequencies required Duplexer Cradle (T ) Blank Panel ( ) Speaker Panel Single/selectable T800temp.V.doc : Issued 09 Sept 999 Page of 4
10 Purchase Order Number: PART 04. EQUIPMENT TYPE REQUIRED :- SERIES I SERIES II PART 05. DO YOU KNOW THE FREQUENCIES AT THIS TIME? No To be advised Attached Yes Tx MHz CTCSS Hz Rx MHz CTCSS Hz Channel Panel Eprom Info To be advised Attached PART 06. AUXILLIARY EQUIPMENT :- Description OPTION REQUIRED Qty Part Number Automatic For Freq:- Mhz Changeover Unit Kit Installation Kit PART 07. ANCILLIARY EQUIPMENT :- Description Qty Part Number Cabinet Microphone Programming Software Module Extender with D Ranges(standard) Module Extender with way D Range(QS) Service Manuals PART 08. BRIEF DESCRIPTION : (Diagram / Information Sheet Attached?) Yes No PART 09. ADDITIONAL COMMENTS :- PART 0. DATE REQUIRED T800temp.V.doc : Issued 09 Sept 999 Page of 4
11 Purchase Order Number: PART. TRANSMITTER/EXCITER PARAMETERS :- STANDARD CUSTOMISED (As Manual) (Identify Requirements) Channel Spacing : C.T.C.S.S. :.5 khz No 0.0 khz Yes 5.0 khz Single Other khz (Freq Hz) Frequency Stability : (VHF).5 ppm Multiple.5 ppm (Pattern Required) (UHF).0 ppm Tx Time Out : External Reference Disabled Transmitter : Enabled 5 Watts (Max Time 5 mins) Duration Mins 50 Watts Tx Tail Time : (For 800MHz Max 70W) 70 Watts Disabled 00 Watts Enabled Other Watts (Max Time 5 secs) Duration Secs Number of Channels : Audio Response : Single Pre-emphasised (Freq MHz) Flat Multiple Special Modifications (Pattern Required) No Yes Level : dbm Refer to Part 08 PART. RECEIVER PARAMETERS :- STANDARD CUSTOMISED (As Manual) (Identify Requirements) Channel Spacing : C.T.C.S.S. :.5 khz No 0.0 khz Yes 5.0 khz Single Other khz (Freq Hz) Frequency Stability : (VHF).5 ppm Multiple.5 ppm (Pattern Required) (UHF).0 ppm External Reference Audio Response : Number of Channels : De-emphasised Single Flat (Freq MHz) Multiple R.S.S.I. : (UHF Equipment ly) (Pattern Required) Note:All other equipment No has RSSI as standard Yes Special Modifications Level : dbm No Yes Gating Operating Level : Refer to Part 08 T800temp.V.doc : Issued 09 Sept 999 Page of 4
12 SYSTEM BLOCK DIAGRAM () T800temp.V.doc : Issued 09 Sept 999 Page 4 of 4
13 M800RACK Section T800SII Numbering System Conventional Rack Systems ordered from RSD using the adjacent Numbering System will be configured as follows: Rack Configuration The Racks used in these configurations are as per Section of this guide, which illustrates the factory default specifications. Each Rack is fully wired and set-up for AC or DC power supply options. (Refer to Section ). A Speaker / Programming Port Panel and all required Blank Panels and are fitted as standard to each rack as required. If the System Type is code B, a co-axial relay is fitted as standard. If any other code is used, then relays must be requested if required. Module Configuration All Rx and Ex/Tx modules are fitted with second D-ranges as Standard. ie.(t8xx-xx-000) All technical information on this Rack configuration is available from RSD. Copyright TEL 0/8/99
14 Excellence in Radio Communications Carrier Microphone Excellence in Radio Communications Excellence in Radio Communications Excellence in Radio Communications Order Number System 4//999 System Type Frequency Band RF Output Channel Spacing Duplexer Ancillary Options B A W D 0 0 B = R = S = P = T = D = Q = H = L = Base Station Repeater Slimline Portable Tone Remote Dual Base Quasi-Sync HSO Rack Liberty A = B = C = D = E = F = G = H = I = J = K = L = MHz 6-56 MHz MHz MHz MHz MHz MHz MHz 0-44 MHz 4-70 MHz MHz 0-80 MHz = = = 4 = (T800--XXXX) (T800--XXXX) (T ) (T800-5-XXXX) (T800-7-XXXX) (T X) (T800-4-XXXX) (T800-8-XXXX) (T XXXX) (T8x-xx) (T8x-x) (T8x-x) (T85x-x) (T85x-x) (T85x-x) (T88x-x) (T88x-x) (T86x-x) (T86x-x) (T86x-x) (T87x-x) 5 Watts 50 Watts 90 or 00 Watts 5 Watts N =.5 khz M = 0 khz W = 5 khz E = 50 khz A = B = D = 0 = = = 0 = = = = 4 = 5 = Slimline DC External supply No Duplexer Fitted 50 Watt Duplexer Fitted Coaxial Relay This item code is always set to (0) for Slimline configurations. If Duplexer item code is set to (), then Base/Repeater/Slimline Requirement sheet must be completed. No Ancillary Option Circuit Breaker Panel Tx/Rx Metering & Unit Multi-Channel Panel (00 CH) Multi-Channel Panel (0 CH) Alarm Module (T ) (T ) (T ) (T XX) (T ) (TA ) (TA87-0) (TA ) Example: BAWD00 Transmitter Speaker Panel Equipment list B = A = = W = D = 0 = 0 = Base Station MHz 5 Watts 5 khz DC External supply Fitted No Duplexer Fitted No Ancillaries Fitted T T T This set-up comes complete with all required Blank Panels and a Speaker/Programming Panel
15 Rack and Function Cross-Reference Chart Relevant Module T number Cross- Reference Section Module Function T8n6 - T8n7 - T8n7 - T8n7 - T8n7 - X800-9x-000y X800-9x-000y X800-9x-000y Default Options shown. Refer to Sections & Single system Dual system Receive only 5W Transmit 50W Transmit 00W Transmit AC External.8V DC Battery back-up Converter Circuit breaker Optional Duplexer Optional fan Optional relay Optional CH/PNL Portable T80 Remote/Alarm Link Quasi Sync Alarms (TA6) Speaker (T88) Paging Fylde TSC Interface Slimline T x00 T x06 T x0 T x T x T x4 T x5 T x6 T x7 T x0 T x T x T x T x4 T x00 T x0 T x00 T x0 T x0 0//999
16 Rack and Function Cross-Reference Chart Module Function Single system Dual system Receive only 5W Transmit 50W Transmit 00W Transmit AC External.8V DC Battery back-up Converter Circuit breaker Optional Duplexer Optional fan Optional relay Optional CH/PNL Portable T80 Remote/Alarm Link Quasi Sync Alarms (TA6) Speaker (T88) Paging Fylde TSC Interface Slimline T T T T x00 T x0 T x00 T x00 T x0 T x0 0//999
17 T800 SeriesII Rack and Module Weights Weight (kg) 0.00 Rackframe to house modules.60 to house modules 4.5 to house 4 modules 4.70 to house 5 modules 5.5 to house 6 modules 5.80 to house 7 modules 6.5 T8n5.0 T8n6 Transmitter.05 T8n7 Exciter.05 50W Amplifier.0 00W Amplifier.55 T80n.0 Circuit breaker 0.50 DC Converter Module 0.90 TA6 Alarm Unit 0.85 T TA807 Channel Panel 0.5 TA0 Combiner.80 Duplexer.5 Duplexer Cradle 0.55 T80 Tone Remote / Alarm.55 T80-0 High Stability Oscillator.50 Portable Repeater Case to house modules (Standard) 6.00 to house 4 modules 6.5 Batteries (Standard) //999
18
19 T800 Series II Conventional Equipment Reference Guide Rack Configuration
20 M800RACK Section T800--0x00 A standard single channel rack for repeater or base station use; up to 00 Watt output. Operational Characteristics Single channel Up to 00W with option of Transmitter or Exciter / PA combination Speaker / Programming panel DC line fuse Earth stud Backplane interface Options x = 0 AC only x = External DC only x = AC and External DC x = AC and Battery x = 4 External DC and Battery x = 5 AC and External DC and Battery Configuration Options Duplexer Coaxial Relay Fans - single or double Interfaces to Changeover Module TA70-00-xxxx using TA installation kit microphone DC converter Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown) 5W -.5kg 50W kg 00W kg NOTE: This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards. Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
21 FRONT VIEW Excellence in Radio Communications Exciter Amplifier Excellence in Radio Communications Speaker Panel Overload Standby Carrier Low forward power High reverse power Microphone FAN () TRANSMITTER BLANK DUPLEXER BLANK REAR VIEW Speaker Panel PA Exciter Output.8V 5A Max T REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS EARTH STUD FAN () OUTPUT ONLY.8V MAX AMPS FUSE TB ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T RACK, FRAME ONLY, ASSEMBLED T DOUBLE GUIDE KIT T GUIDE PA 50W KIT T T800 PS GUIDE KIT T SPEAKER / PROGRAM PANEL SECTION 8 T FIXING KIT ONLY T BLANKING BRACKET / FRONT PANEL SECTION 8 T BACKPLANE SECTION 5 X POWER RAIL (STANDARD) SECTION T A I T Radio Communications 5 4 Drawing name changed Drawing No changed and Ref. added Parts list added AMM ABB 6//99 AMM ABB 4/8/99 AMM ABB 8//99 TITLE: RACK, SNGL<00W, (OPT BD Christchurch Change of Title AMM ABB 4//98 New Zealand Original Version AMM ABB /0/98 Drawn Checked Date DRAWING: T800--0x00 RACKFRAME
22 M800RACK Section T800--0x06 A 5 Watt single channel rack for repeater or link use. Operational Characteristics Single channel Up to 5W Transmitter Output Speaker / Programming panel DC line fuse Earth stud Backplane interface Options x = 0 AC only x = External DC only x = AC and External DC x = AC and Battery x = 4 External DC and Battery x = 5 AC and External DC and Battery Configuration Options Duplexer Coaxial Relay Fans - single or double Interfaces to Changeover Module TA70-00-xxxx using TA installation kit Microphone DC converter Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown) 7.85kg NOTE: This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards. Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
23 FRONT VIEW Excellence in Radio Communications Excellence in Radio Communications Excellence in Radio Communications Speaker Panel Transmitter Excellence in Radio Communications Carrier Microphone REAR VIEW Transmitter Speaker Panel EARTH STUD T DC INPUT FUSE TB REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS OUTPUT ONLY.8V MAX AMPS ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T RACK, FRAME ONLY, ASSEMBLED T DOUBLE GUIDE KIT T SPEAKER / PROGRAM PANEL SECTION 8 T FIXING KIT ONLY T BLANKING BRACKET / FRONT PANEL SECTION 8 T BACKPLANE SECTION 5 X POWER RAIL (STANDARD) SECTION T A I T Radio Communications TITLE: RACK, REPEATER/LINK END DC Christchurch Drawing No changes and Ref. added AMM ABB 4/8/99 New Zealand Original Version AMM ABB 9//99 Drawn Checked Date DRAWING: T800--0x06
24 M800RACK Section T800--0x0 A single channel repeater or base station rack based on the standard T800--0x00, with the option of fitting a Channel Panel. Operational Characteristics Single channel Up to 00W with option of Transmitter or Exciter / PA combination Speaker / Programming panel DC line fuse Earth stud Backplane interface Options x = 0 AC only x = External DC only x = AC and External DC x = AC and Battery x = 4 External DC and Battery x = 5 AC and External DC and Battery Configuration Options Channel Panel Duplexer Coaxial Relay Fans - single or double Interfaces to Changeover Module TA70-00-xxxx using TA installation kit microphone DC converter Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Length - mm plus 50mm clearance space Weight (rackframe with modules shown) 5W -.5kg 50W kg 00W kg Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
25 FRONT VIEW Excellence in Radio Communications Exciter Amplifier Excellence in Radio Communications Speaker Panel Overload Standby Carrier Low forward power High reverse power Microphone FAN () TRANSMITTER BLANK DUPLEXER CHANNEL PANEL BLANK REAR VIEW Speaker Panel PA Exciter Output.8V 5A Max T REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS EARTH STUD FAN () OUTPUT ONLY.8V MAX AMPS FUSE TB ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T RACK, FRAME ONLY, ASSEMBLED T DOUBLE GUIDE KIT T GUIDE PA 50W KIT T T800 PS GUIDE KIT T SPEAKER / PROGRAM PANEL SECTION 8 T FIXING KIT ONLY T BLANKING BRACKET / FRONT PANEL SECTION 8 T BACKPLANE CH-PNL SECTION 5 X POWER RAIL (STANDARD) SECTION T A I T Radio Communications 5 4 Drawing name changed Drg No changed and Ref added Parts list added AMM ABB 6//99 AMM ABB 5/8/99 AMM ABB 8//99 TITLE RACK, SNGL<00W, (CH PNL Christchurch Change of Title AMM ABB 4//98 New Zealand Original Version AMM ABB /0/98 Drawn Checked Date DRAWING: T800--0x0 RACKFRAME
26 M800RACK Section T800--0x A only rack with alarm outputs, AC power supply and dual battery back-up connections. Operational Characteristics Receive only - up to 4 receivers Speaker / Programming panel - with Speaker Select Switch Alarm Panel DC line fuse Earth stud Backplane interface Options x = 0 AC only x = External DC only x = AC and External DC x = AC and Battery x = 4 External DC and Battery x = 5 AC and External DC and Battery Configuration Options Channel Panel Fans - single or double DC converter Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown) 7.75kg Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
27 FRONT VIEW Speaker Panel Alarm Panel 4 5 Overload 6 Standby Speaker Select PSU Fail Batt Fail Forward Reflected Alarm# Alarm# Alarm# Alarm#4 Forward Test CHANNEL PANEL or BLANK REAR VIEW Alarm Speaker Panel Output.8V 5A Max T T REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS EARTH STUD FUSE DIODE PACK BATTERY BACK-UP TB OUTPUT ONLY.8V MAX AMPS ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T RACK, FRAME ONLY, ASSEMBLED BATT BACK-UP T DOUBLE GUIDE KIT T GUIDE KIT T500/00 DOUBLE 'D' T T800 PS GUIDE KIT T SPEAKER / PROGRAM PANEL WITH 6-WAY SWITCH SECTION 8 T FIXING KIT ONLY T BACKPLANE SECTION 5 X POWER RAIL (STANDARD) SECTION T A I T Radio Communications Christchurch 4 4 drg No changed and Ref added Frame label removed Parts list added Change of Title AMM ABB 5/8/99 AMM ABB /7/99 AMM ABB 8//99 AMM ABB 4//98 TITLE: RACK, RX ONLY AC (4RX + ALARM + SPK) New Zealand Original Version AMM ABB 0/0/98 Drawn Checked Date DRAWING: T800--0x
28 M800RACK Section T800--0x Receive only rack similar to T800--0x; but with no alarm outputs. Operational Characteristics Receive only - up to 4 receivers Speaker / Programming panel - with Speaker Select Switch DC line fuse Earth stud Backplane interface Options x = 0 AC only x = External DC only x = AC and External DC x = AC and Battery x = 4 External DC and Battery x = 5 AC and External DC and Battery Configuration Options Channel Panel Fans - single or double DC converter Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown) 6.5kg Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
29 FRONT VIEW Speaker Panel Excellence in Radio Communications 4 5 Overload 6 Standby Speaker Select CHANNEL PANEL or BLANK REAR VIEW Speaker Panel Output.8V 5A Max T T REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS EARTH STUD OUTPUT ONLY.8V MAX AMPS FUSE TB ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T RACK, FRAME ONLY, ASSEMBLED T DOUBLE GUIDE KIT T T800 PS GUIDE KIT T BLANKING BRACKET / FRONT PANEL SECTION 8 T SPEAKER / PROGRAM PANEL WITH 6-WAY SWITCH SECTION 8 T FIXING KIT ONLY T BACKPLANE SECTION 5 X POWER RAIL (STANDARD) SECTION T A I T Radio Communications drg No changed and Ref added Parts list added AMM ABB 5/8/99 AMM ABB 8//99 TITLE: RACK, RX ONLY AC (4RX + SPK) Christchurch Change of Title AMM ABB 4//98 New Zealand Original Version AMM ABB 0/0/98 Drawn Checked Date DRAWING: T800--0x
30 M800RACK Section T800--0x A dual 50 Watt channel rack, with AC power supply and DC battery back-up connections. Operational Characteristics Dual channel 50W output Speaker / Programming panel DC line fuse Earth stud Backplane interface Options x = 0 AC only x = External DC only Not Available (see T800--0x6) x = AC and External DC x = AC and Battery x = 4 External DC and Battery Not Available (see T800--0x6) x = 5 AC and External DC and Battery Configuration Options Coaxial Relay Fans - single or double Interfaces to Changeover Module TA70-00-xxxx using TA installation kit microphone Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown).55kg Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
31 FRONT VIEW Amplifier Exciter Exciter Amplifier Overload Standby Low forward power Carrier Carrier Low forward power High reverse power High reverse power Microphone Microphone FAN () FAN () REAR VIEW PA Exciter Exciter PA T Output.8V 5A Max T FAN () REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS EARTH STUD FAN () DIODE PACK FUSE FUSE BATTERY BACK-UP TB OUTPUT ONLY.8V MAX AMPS The rack configuration has been changed to reduce the risk of overheating in some environments. It is recommended that the optional fans are fitted. ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T RACK, FRAME ONLY, ASSEMBLED BATTERY BACK-UP T DOUBLE GUIDE KIT T GUIDE PA 50W KIT T T800 PS GUIDE KIT T BACKPLANE SECTION 5 X POWER RAIL (STANDARD) SECTION T A I T Radio Communications Drg name changed AMM ABB 9//99 TITLE: RACK, DUAL x50w Christchurch Drg No change, ref added, PS,PA moved AMM ABB 5/8/99 New Zealand Original Version AMM ABB 8//99 Drawn Checked Date DRAWING: T800--0x RACKFRAME
32 M800RACK Section T800--0x4 A dual 5 Watt channel rack, with AC power supply and DC battery back-up connections. Operational Characteristics Dual channel 5W output Dual Speaker / Programming panel (switchable) DC line fuse Earth stud Backplane interface Options x = 0 AC only x = External DC only Not Available (see T800--0x7) x = AC and External DC x = AC and Battery x = 4 External DC and Battery Not Available (see T800--0x7) x = 5 AC and External DC and Battery Configuration Options Channel Panel Individual Speaker / Programming panels Duplexer Coaxial Relay Fans - single or double Interfaces to Changeover Module TA70-00-xxxx using TA installation kit microphone DC converter Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown) 6.05kg Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
33 O FF FRONT VIEW Excellence in Radio Communications Transmitter Speaker Panel Transmitter Overload Standby Carrier RX RX O FF Carrier Microphone Microphone SPEAKER (T ) DUPLEXER AND/OR CHANNEL PANEL SPEAKER (T ) DUPLEXER AND/OR CHANNEL PANEL REAR VIEW Transmitter Speaker Panel Transmitter Output.8V 5A Max T T REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS EARTH STUD DIODE PACK FUSE FUSE BATTERY BACK-UP TB OUTPUT ONLY.8V MAX AMPS ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T RACK, FRAME ONLY, ASSEMBLED, BATTERY BACK-UP T DOUBLE GUIDE KIT T T800 PS GUIDE KIT T SPEAKER / PROGRAM PANEL SECTION 8 T BLANKING BRACKET / FRONT PANEL SECTION 8 T FIXING KIT ONLY T BACKPLANE SECTION 5 X POWER RAIL (STANDARD) SECTION T A I T Radio Communications 5 4 Drg name changed Dual spk replaced by switched spk Drg No changed, ref added, PA, PS moved AMM ABB 9//99 AMM ABB /9/99 AMM ABB 5/8/99 TITLE: RACK, DUAL x5w, SPK SW Christchurch Parts list added, fans removed AMM ABB 8//99 New Zealand Original Version AMM ABB //99 Drawn Checked Date DRAWING: T800--0x4 RACKFRAME
34 M800RACK Section T800--0x5 A dual 5 Watt channel rack with a separate power supply for each channel. The speaker panel can be switched between receivers. Operational Characteristics Dual channel 5W output Speaker / Programming panel, with Selectable Switch DC line fuse Earth stud Backplane interface Options x = 0 AC only x = External DC only x = AC and External DC x = AC and Battery x = 4 External DC and Battery x = 5 AC and External DC and Battery Configuration Options Coaxial Relay Fans - single or double Interfaces to Changeover Module TA70-00-xxxx using TA installation kit microphone DC converter Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown) 6.6kg Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
35 O FF FRONT VIEW Transmitter Speaker Panel Transmitter Overload Overload Standby Carrier RX RX O FF Carrier Standby Microphone Microphone REAR VIEW Transmitter Speaker Panel Transmitter Output.8V 5A Max T T Output.8V 5A Max REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS EARTH STUD OUTPUT ONLY.8V MAX AMPS DIODE PACK FUSE FUSE TB ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T RACK, FRAME ONLY, ASSEMBLED T DOUBLE GUIDE KIT T T800 PS GUIDE KIT T SPEAKER/PROGRAM PANEL WITH POSITION SWITCH SECTION 8 T FIXING KIT ONLY T BACKPLANE SECTION 5 X POWER RAIL (STANDARD) SECTION T A I T Radio Communications Drg name changed Drg No changed, Ref added, Relay removed AMM ABB 9//99 AMM ABB 5/8/99 TITLE: RACK, DUAL x5 WATT, ( P/SUP Christchurch Standard supply table added AMM ABB //99 New Zealand Original Version AMM ABB //99 Drawn Checked Date DRAWING: T800--0x5 RACKFRAME
36 M800RACK Section T800--0x6 A dual 50 Watt channel rack for use in DC only situations. Operational Characteristics Dual channel 50W output per channel Speaker / Programming panel, with Selectable Switch DC line fuse Earth stud Backplane interface Options x = 0 AC only Not Available x = External DC only x = AC and External DC Not Available x = AC and Battery Not Available x = 4 External DC and Battery x = 5 AC and External DC and Battery Not Available Configuration Options Coaxial Relay Fans - single or double Interfaces to Changeover Module TA70-00-xxxx using TA installation kit microphone Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown) 0.7kg Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
37 O FF FRONT VIEW Amplifier Exciter Speaker Panel Exciter Amplifier Low forward power Carrier RX RX O FF Carrier Low forward power High reverse power High reverse power Microphone Microphone FAN () FAN () REAR VIEW PA Exciter Speaker Panel Exciter PA EARTH STUD FAN () T T FAN () DC INPUT FUSE FUSE TB REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS OUTPUT ONLY.8V MAX AMPS The rack configuration has been changed to reduce the risk of overheating in some environments. It is recommended that the optional fans are fitted. ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T RACK, FRAME ONLY, ASSEMBLED T DOUBLE GUIDE KIT T GUIDE PA 50W KIT T SPEAKER/PROGRAM PANEL WITH POSITION SWITCH SECTION 8 T FIXING KIT ONLY T BACKPLANE SECTION 5 X POWER RAIL (STANDARD) SECTION T A I T Radio Communications Drg name changed AMM ABB 9//99 TITLE: RACK, DUAL x50w, (SPK SWITCHED) Christchurch Drg No changed, Ref added, PA moved AMM ABB 5/8/99 New Zealand Original Version AMM ABB 5//99 Drawn Checked Date DRAWING: T800--0x6 RACKFRAME
38 M800RACK Section T800--0x7 A dual 5 Watt channel rack for use in DC only situations. Operational Characteristics Dual channel 5W output per channel Speaker / Programming panel, with Selectable Switch DC line fuse Earth stud Backplane interface Options x = 0 AC only Not Available (see T800--0x4) x = External DC only x = AC and External DC Not Available (see T800--0x4) x = AC and Battery Not Available (see T800--0x4) x = 4 External DC and Battery x = 5 AC and External DC and Battery Not Available (see T800--0x4) Configuration Options Channel Panel Duplexer Coaxial Relay Fans - single or double Interfaces to Changeover Module TA70-00-xxxx using TA installation kit microphone Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown).kg Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
39 O FF FRONT VIEW Excellence in Radio Communications Transmitter Speaker Panel Transmitter Excellence in Radio Communications Carrier RX RX O FF Carrier Microphone Microphone DUPLEXER and/or CHANNEL PANEL BLANK REAR VIEW DUPLEXER and/or CHANNEL PANEL Transmitter Speaker Panel Transmitter DR T DR T REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS EARTH STUD DC INPUT FUSE FUSE TB OUTPUT ONLY.8V MAX AMPS ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T RACK, FRAME ONLY, ASSEMBLED T DOUBLE GUIDE KIT T SPEAKER / PROGRAM PANEL -WAY SWITCH SECTION 8 T FIXING KIT ONLY T BLANKING BRACKET / FRONT PANEL SECTION 8 T BACKPLANE SECTION 5 X POWER RAIL (STANDARD) SECTION T A I T Radio Communications Drg name changed AMM ABB 9//99 TITLE: RACK, DUAL X5W, (SPKR SW) Christchurch Drg No changed, Ref added AMM ABB 5/8/99 New Zealand Original Version AMM ABB /6/99 Drawn Checked Date DRAWING: T800--0x7 RACKFRAME
40 M800RACK Section T800--0x0 A single repeater or base station channel rack up to 00 Watt maximum output. The rack can accommodate an Rx/Tx panel and AC power input. Operational Characteristics Single channel Up to 00W with option of Transmitter or Exciter / PA combination Speaker / Programming panel Rx/Tx Panel DC line fuse Earth stud Backplane interface Options x = 0 AC only x = External DC only Not Available x = AC and External DC x = AC and Battery x = 4 External DC and Battery Not Available x = 5 AC and External DC and Battery Configuration Options Channel Panel Duplexer Coaxial Relay Fans - single or double Interfaces to Changeover Module TA70-00-xxxx using TA installation kit microphone DC converter Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown) 5W -.kg 50W kg 00W - 6.kg NOTE: This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards. Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
41 FRONT VIEW Rx/Tx Exciter Amplifier Excellence in Radio Communications Speaker Panel Overload Standby Carrier Low forward power High reverse power Volts Rx Signal Rx Tx Fwd Pwr Rev Pwr Microphone FAN () TRANSMITTER BLANK PANEL DUPLEXER CHANNEL PANEL REAR VIEW Speaker Panel PA Exciter Rx/Tx MON T Output.8V 5A Max T T REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS EARTH STUD FAN () OUTPUT ONLY.8V MAX AMPS FUSE TB ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T RACK, FRAME ONLY, ASSEMBLED T DOUBLE GUIDE KIT T GUIDE KIT T500/00 SINGLE 'D' T GUIDE PA 50W KIT T T800 PS GUIDE KIT T SPEAKER / PROGRAM PANEL SECTION 8 T FIXING KIT ONLY T BLANKING BRACKET / FRONT PANEL SECTION 8 T BACKPLANE SECTION 5 T PERSONALITY BOARD SECTION 6 X POWER RAIL (STANDARD) SECTION T A I T Radio Communications 4 Drg name changed Drg No changed, Ref added AMM ABB 9//99 AMM ABB 5/8/99 TITLE: RACK, SNGL<00W, (MONITOR) Christchurch Parts list added AMM ABB 8//99 New Zealand Original Version AMM ABB //99 Drawn Checked Date DRAWING: T800--0x0 RACKFRAME
42 M800RACK Section T800--0x A single 5 Watt repeater or base station channel rack to accommodate an Rx/Tx and rack mounted circuit breaker for protection on the DC power input. Operational Characteristics Single channel 5W output only Speaker / Programming panel Panel circuit breaker DC line fuse Earth stud Backplane interface Options x = 0 AC only Not Available x = External DC only x = AC and External DC Not Available x = AC and Battery Not Available x = 4 External DC and Battery x = 5 AC and External DC and Battery Not Available Configuration Options Channel Panel Duplexer Coaxial Relay Fans - single or double Interfaces to Changeover Module TA70-00-xxxx using TA installation kit microphone Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown) 0.5kg NOTE: This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards. Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
43 FRONT VIEW Rx/Tx Transmitter Excellence in Radio Communications Excellence in Radio Communications Speaker Panel Circuit Breaker Carrier V Volts Rx Signal Rx Tx Fwd Pwr Rev Pwr Microphone 0 DUPLEXER CHANNEL PANEL REAR VIEW Circuit Breaker Speaker Panel Transmitter Rx/Tx MON T T T REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS EARTH STUD OUTPUT ONLY.8V MAX AMPS DC INPUT TB ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T RACK, FRAME ONLY, ASSEMBLED T DOUBLE GUIDE KIT T GUIDE KIT T500/00 SINGLE 'D' T GUIDE PA 50W KIT T SPEAKER / PROGRAM PANEL SECTION 8 T FIXING KIT ONLY T BLANKING BRACKET / FRONT PANEL SECTION 8 T PANEL CIRCUIT BREAKER WITH 0AMP SWITCH SECTION 8 T BACKPLANE SECTION 5 T PERSONALITY BOARD SECTION BLANKING FRONT PANEL ONLY SECTION 8 X POWER RAIL (STANDARD) SECTION T A I T Radio Communications 5 4 Drg name changed Drg No changed, Ref added Parts list added AMM ABB 9//99 AMM ABB 5/8/99 AMM ABB 8//99 TITLE: RACK, SNGL<5W, (MONITOR) Christchurch Change of Title AMM ABB 4//98 New Zealand Original Version AMM ABB /0/98 Drawn Checked Date DRAWING: T800--0x RACKFRAME
44 M800RACK Section T800--0x A single 50 Watt repeater or base station channel rack to accommodate an Rx/Tx and rack mounted circuit breaker for protection on the DC power input. Operational Characteristics Single channel 50W output only Speaker / Programming panel Panel circuit breaker DC line fuse Earth stud Backplane interface Options x = 0 AC only Not Available x = External DC only x = AC and External DC Not Available x = AC and Battery Not Available x = 4 External DC and Battery x = 5 AC and External DC and Battery Not Available Configuration Options Channel Panel Duplexer Coaxial Relay Fans - single or double Interfaces to Changeover Module TA70-00-xxxx using TA installation kit microphone Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown) 4.kg NOTE: This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards. Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
45 FRONT VIEW Rx/Tx Exciter Amplifier Excellence in Radio Communications Speaker Panel Circuit Breaker Carrier Low forward power V High reverse power Volts Rx Signal Rx Tx Fwd Pwr Rev Pwr Microphone 0 FAN () DUPLEXER CHANNEL PANEL REAR VIEW Circuit Breaker Speaker Panel PA Exciter Rx/Tx MON T T T REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS EARTH STUD FAN () OUTPUT ONLY.8V MAX AMPS DC INPUT TB ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T RACK, FRAME ONLY, ASSEMBLED T DOUBLE GUIDE KIT T GUIDE KIT T500/00 SINGLE 'D' T GUIDE PA 50W KIT T SPEAKER / PROGRAM PANEL SECTION 8 T FIXING KIT ONLY T BLANKING BRACKET / FRONT PANEL SECTION 8 T PANEL CIRCUIT BREAKER WITH 0AMP SWITCH SECTION 8 T BACKPLANE SECTION 5 T PERSONALITY BOARD SECTION 6 X POWER RAIL (STANDARD) SECTION T A I T Radio Communications 5 4 Drg name changed Drg No changed, Ref added Parts list added AMM ABB 9//99 AMM ABB 5/8/99 AMM ABB 8//99 TITLE: RACK, SNGL<=50W, (MONITOR) Christchurch Change of Title AMM ABB 4//98 New Zealand Original Version AMM ABB /0/98 Drawn Checked Date DRAWING: T800--0x RACKFRAME
46 M800RACK Section T800--0x A single channel rack with 50 Watt maximum output, alarm outputs and AC power supply. Operational Characteristics Single channel Up to 50W output Speaker / Programming panel Alarm Panel DC line fuse Earth stud Backplane interface Options x = 0 AC only x = External DC only x = AC and External DC x = AC and Battery x = 4 External DC and Battery x = 5 AC and External DC and Battery Configuration Options Channel Panel Duplexer Coaxial Relay Fans - single or double Interfaces to Changeover Module TA70-00-xxxx using TA installation kit microphone DC converter Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown) 5W -.kg 50W kg NOTE: This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards. Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
47 FRONT VIEW Alarm Panel Exciter Amplifier Excellence in Radio Communications Speaker Panel Overload PSU Fail Carrier Low forward power Standby Batt Fail Forward High reverse power Reflected Alarm# Alarm# Microphone Alarm# Alarm#4 Forward Test FAN () TRANSMITTER BLANK DUPLEXER CH/PNL BLANK REAR VIEW Speaker Panel PA Transmitter or Exciter Alarm Output.8V 5A Max T T Personality Board REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS EARTH STUD DIODE PACK FAN () FUSE BATTERY BACK-UP TB OUTPUT ONLY.8V MAX AMPS ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION T RACK, FRAME ONLY, ASSEMBLED T DOUBLE GUIDE KIT T GUIDE PA 50W KIT T GUIDE KIT T500/00 T T800 PS GUIDE KIT T SPEAKER/PROGRAM PANEL T FIXING KIT ONLY T BLANKING BRACKET / F-PNL KIT T BACKPLANE T PERSONALITY BOARD + CH/PNL + ALARMS (0V) X POWER RAIL (STANDARD) QTY REFERENCE SECTION 8 SECTION 8 SECTION 5 SECTION 6 SECTION T A I T Radio Communications 4 Drg name changed Drg No changed, Ref added AMM ABB 9//99 AMM ABB 5/8/99 TITLE: RACK, SNGL<00W, (ALARMS 0V) Christchurch New Zealand Change personality board Original Version AMM ABB 0//99 AMM ABB 5//99 Drawn Checked Date DRAWING: T800--0x RACKFRAME
48 M800RACK Section T800--0x4 A single channel rack with 50 Watt maximum output, alarm outputs (LO) and AC power supply. Operational Characteristics Single channel Up to 50W output Speaker / Programming panel Alarm Panel DC line fuse Earth stud Backplane interface Options x = 0 AC only x = External DC only x = AC and External DC x = AC and Battery x = 4 External DC and Battery x = 5 AC and External DC and Battery Configuration Options Channel Panel Duplexer Coaxial Relay Fans - single or double Interfaces to Changeover Module TA70-00-xxxx using TA installation kit microphone DC converter Mechanical Characteristics 5 Rack Units x 9 rack to house up to 7 modules Size Height - mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown) 5W -.kg 50W kg NOTE: This product offers the versatility of fitting personality boards to provide customised solutions for specific requirements. Refer to RSD for design and build of personality boards. Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
49 FRONT VIEW Alarm Panel Exciter Amplifier Excellence in Radio Communications Speaker Panel Overload PSU Fail Carrier Low forward power Standby Batt Fail Forward High reverse power Reflected Alarm# Alarm# Microphone Alarm# Alarm#4 Forward Test FAN () TRANSMITTER BLANK DUPLEXER CH/PNL BLANK REAR VIEW Speaker Panel PA Transmitter or Exciter Alarm Output.8V 5A Max T T Personality Board REFER TO SECTION OF THE REFERENCE GUIDE FOR POWER RAIL OPTIONS EARTH STUD DIODE PACK FAN () FUSE BATTERY BACK-UP TB OUTPUT ONLY.8V MAX AMPS ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION T RACK, FRAME ONLY, ASSEMBLED T DOUBLE GUIDE KIT T GUIDE PA 50W KIT T GUIDE KIT T500/00 T T800 PS GUIDE KIT T SPEAKER/PROGRAM PANEL T FIXING KIT ONLY T BLANKING BRACKET / F-PNL KIT T BACKPLANE T PERSONALITY BOARD + CH/PNL + ALARMS (LO) X POWER RAIL (STANDARD) QTY REFERENCE SECTION 8 SECTION 8 SECTION 5 SECTION 6 SECTION T A I T Radio Communications TITLE: RACK, SNGL<00W, (ALARMS LO) Christchurch New Zealand Drg name changed Original Version AMM ABB 9//99 AMM ABB 7/9/99 Drawn Checked Date DRAWING: T800--0x4 RACKFRAME
50 M800RACK Section T800--0x00 A single channel rack with 5 Watt maximum output mounted in a RU Slimline configuration for use in DC situations. Operational Characteristics Single channel Up to 5W output Speaker / Programming Port Options x = 0 AC only Not Available (see T800--0x0) x = External DC only x = AC and External DC Not Available x = AC and Battery Not Available x = 4 External DC and Battery x = 5 AC and External DC and Battery Not Available Configuration Options Coaxial Relay Microphone Mechanical Characteristics Rack Units x 9 rack to house up to 7 modules Size Height - 89mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown) 5W.9kg This configuration includes and Transmitter modules. (to be specified when ordering) Copyright TEL 0/8/99
51 FRONT VIEW Transmitter Gate Gating Level Carrier Microphone Exciter Out T800II Slimline REAR VIEW Transmitter TB ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T SLIMLINE ASSEMBLY KIT + CABLES T8n5-nn-nnnn RECEIVER SECTION 8 T8n6-nn-nnnn TRANSMITTER SECTION 8 T A I T Radio Communications TITLE: SLIMLINE 5W DC Christchurch New Zealand Original AMM ABB 0/9/99 Version Drawn Checked Date DRAWING: T800--0x00
52 M800RACK Section T800--0x0 A single channel rack with 5 Watt maximum output mounted in a RU Slimline configuration, with an AC power supply. Operational Characteristics Single channel Up to 5W output Speaker / Programming Port Options x = 0 AC only x = External DC only Not Available (see T800--0x00) x = AC and External DC x = AC and Battery x = 4 External DC and Battery Not Available x = 5 AC and External DC and Battery Configuration Options Coaxial Relay Microphone Mechanical Characteristics Rack Units x 9 rack to house up to 7 modules Size Height - 89mm Width - 48mm Depth - mm plus 50mm clearance space Weight (rackframe with modules shown) 5W 8.55kg This configuration includes and Transmitter modules. (to be specified when ordering). Copyright TEL 0/8/99
53 FRONT VIEW Transmitter Gate Gating Level Carrier Microphone Exciter Out T800II Slimline REAR VIEW Transmitter TB ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T SLIMLINE ASSEMBLY KIT + CABLES + POWER SUPPLY T8n5-nn-nnnn RECEIVER SECTION 8 T8n6-nn-nnnn TRANSMITTER SECTION 8 T A I T Radio Communications TITLE: SLIMLINE 5W AC Christchurch New Zealand Original AMM ABB 0/9/99 Version Drawn Checked Date DRAWING: T800--0x0
54 M800RACK Section T A single 5W channel, housed in a portable case with sealed lead acid batteries. Operational Characteristics Single channel Up to 5W output DC only operation - Batteries and external DC supply input Speaker / Programming panel DC line fuse Backplane interface Battery Isolation Switch Configuration Options Channel Panel Duplexer Coaxial Relay Antenna Mechanical Characteristics Portable case to house up to 4 modules Top Mounting Duplexer Tray Size Case ly with Handles and Connectors Height - 4mm 05mm Width - 55mm 00mm Depth - 460mm 460mm Weight (rackframe with modules shown) 5.85kg CAUTION: If operating above 5 Watts, front and rear covers must be removed. Rack Items Supplied as Standard does not include modules other than those listed on the drawing. Copyright TEL 0/8/99
55 FRONT VIEW Transmitter Speaker Panel Carrier Microphone TALK THROUGH EXTERNAL DC BASE STATION REPEATER BATTERY OPERATION T8n5 -nn-000 T8n6 -nn-000 T SPKR/PROG PNL or TA CHANNEL CHANNEL PANEL or TA CHANNEL CHANNEL PANEL REAR VIEW Duplexer mounted behind T DC OFF ON FUSE 0A ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION QTY REFERENCE T CASE, PORTABLE REPEATER VERSION T DOUBLE GUIDE KIT T BLANK PANEL AND FIXING KIT T SPEAKER / PROGRAM PANEL SECTION 8 T FIXING KIT ONLY T BACKPLANE SECTION BATTERY SEALED LEAD ACID V 6.5A X W STANDARD LOOM ASSEMBLY WIRING LIST T T A I T Radio Communications 4 Reference added Battery details added AMM ABB 6/8/99 AMM ABB 0/6/99 TITLE: T PORTABLE Christchurch Diode pack alignment corrected AMM ABB /6/99 New Zealand Original Version AMM ABB 4//99 Drawn Checked Date DRAWING: T
Using the TB8100 Base Station as a Talk-Through, Community, or Linked Repeater
Using the TB8100 Base Station as a Talk-Through, Community, or Linked Repeater Application Note TN-743 1 June 2003 Tait Electronics Ltd Page 1 of 8 558 Wairakei Rd, P.O. Box 1645, Christchurch, New Zealand
More informationFixed Equipment. T800 Series II. T800SL Basestations
Fixed Equipment T800 Series II T800SL Basestations www.tait.sk Copyright 2000-2001, WRX Slovakia. All rights reserved. Visit our Web: http://www.tait.sk T800 Series II T800 series II is a comprehensively
More information3.2 T PCB Information
M800-00 T800-22-0000 PCB Information C3.2.1 3.2 T800-22-0000 PCB Information This section contains the following information on the T800-22-0000 backplane PCB. Note: The backplane PCB is available separately
More informationMASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2. Maintenance Manual LBI-30766L. Mobile Communications
L Mobile Communications MASTR II AUXILIARY RECEIVER 19D417546G7 & G8 & ANTENNA MATCHING UNITS 19C321150G1-G2 Printed in U.S.A Maintenance Manual TABLE OF CONTENTS Page SPECIFICATIONS.....................................................
More informationTRANSMITTER COMBINERS
1 TRANSMITTER COMBINERS 30-88 MHz LOWBAND COMBINERS Telewave Lowband and Midband Combiners offer high performance with industry-standard Telewave reliability. Telewave is one of the few remaining manufacturers
More informationT800 Memory & T830 VCO PCB Information
Part E T800 Memory & T830 VCO PCB Information This part of the manual is divided into the sections listed below. These sections provide parts lists, PCB layouts and circuit diagrams for the T800 memory
More informationTechnical Equipment Specification
STATE OF CALIFORNIA Office of the State Chief Information Officer Public Safety Communications Division Technical Equipment Specification Equipment Type: Transmitter/Receiver Mobile Relay/Base/Control
More informationMX800 BASE STATION SPECIFICATIONS
MX800 BASE STATION SPECIFICATIONS Minimum performance to exceed the following for 30MHz to 960MHz*: Conforms but not all bands approved. GENERAL Frequency Range: AS4295-1995, R&TTE EC Directive 1995/05/EC,
More informationEDACS WALL MOUNT STATION. Maintenance Manual. Mobile Communications LBI-31838A TABLE OF CONTENTS
A Mobile Communications EDACS WALL MOUNT STATION TABLE OF CONTENTS SYSTEM BOARD & REGULATOR BOARD.......... LBI-31892 KEY/DISPLAY BOARD MAINTENANCE MANUAL.... LBI-31940 Maintenance Manual Printed in U.S.A.
More informationTHE PUBLIC ADDRESS AMPLIFIER SYSTEM WITH FLEXIBILITY BUILT-IN
THE PUBLIC ADDRESS AMPLIFIER SYSTEM WITH FLEXIBILITY BUILT-IN The Range... T he Mitre range is now a well-proven group of products.with an excellent track record for reliability, Mitre can accommodate
More informationKenwood USA Corporation
Kenwood USA Corporation - Systems Division 3975 Johns Creek Court, Suite 400 Suwanee, GA 30024-1265 Phone 678-474-4700 Toll Free 1-800-TRUNKING (878-6546) Systems Division Fax 678-957-1880 Kenwood USA
More informationAudio Specialties Group Products Division MAS-101 UHF Receive Antenna Combiner Operators Guide
Audio Specialties Group Products Division MAS-101 UHF Receive Antenna Combiner Operators Guide REV-4 TABLE OF CONTENTS SECTION 1:... 3 1.0 Introduction... 3 SECTION 2:... 3 Features... 3 2.1 Standard Configurations...
More informationMaintenance Manual. MTD SERIES 900 MHz, 10-WATT, DATA ONLY MOBILE RADIO. Mobile Communications LBI TABLE OF CONTENTS
Mobile Communications MTD SERIES 900 MHz, 10-WATT, DATA ONLY MOBILE RADIO TABLE OF CONTENTS RF BOARD............................... LBI-38545 AUDIO BOARD............................ LBI-38546 LOGIC BOARD............................
More informationLBI-31564A. Mobile Communications. DELTA - SX MHz RADIO COMBINATIONS (NEGATIVE GROUND ONLY) Maintenance Manual
A Mobile Communications DELTA - SX 136-174 MHz RADIO COMBINATIONS (NEGATIVE GROUND ONLY) Maintenance Manual TABLE OF CONTENTS MILITARY AND SYSTEM SPECIFICATIONS................................. 2-3 COMBINATION
More informationX R T B A S E S T A T I O N S E R I E S
X R T B A S E S T A T I O N S E R I E S The State of the Art XRT Base Station Series was designed for the scanning Telemetry market, as a result of extensive market research into the requirements of utility
More informationLBI-31807D. Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1. Maintenance Manual. Printed in U.S.A.
D Mobile Communications MASTR II REPEATER CONTROL PANEL 19B234871P1 Maintenance Manual Printed in U.S.A. This page intentionally left blank 13 PARTS LIST 12 PARTS LIST LBI-31807 11 PARTS LIST 10 SCHEMATIC
More information411LA Broadband Power Amplifier
411LA Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with
More informationGPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard
GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Standard Key Features Completely self-contained unit. No extra P.C needed. Full information available via LCD. Rubidium Oscillator locked
More information1 KW TOTALLY SOLID STATE DIFFERENTIAL GPS TRANSMITTER ( khz)
GPS1000 1 KW TOTALLY SOLID STATE DIFFERENTIAL GPS TRANSMITTER (282-326 khz) NAUTEL has developed the GPS1000 as an extremely efficient and highly reliable transmitter especially suited for use at remote
More information1. SYSTEM DESCRIPTION NON - DIRECTIONAL RADIO BEACON TRANSMITTER (NDB) JTM-30C
Documentation Rev.Date Rev. Document no. 1. SYSTEM DESCRIPTION NON - DIRECTIONAL RADIO BEACON TRANSMITTER (NDB) JTM-30C 1. SYSTEM DESCRIPTION... 2 1.1 OVERALL SYSTEM DESCRIPTION... 2 1.2 BASIC MODULES...
More informationINSTALLATION and OPERATION INSTRUCTIONS. FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV
INSTALLATION and OPERATION INSTRUCTIONS FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV Page 1 of 15 TABLE OF CONTENTS PARA No. PARAGRAPH PAGE No. 1. OVERVIEW 3 2. COMPONENT
More informationCross-Connect Interface
Cross-Connect Interface User Manual Document #: 050-015-0036R01 November 2006 TASC Systems Inc. Langley, BC Canada Cross-Connect System User Manual Preface This document describes the installation, commissioning
More informationMIRAGE BD-35 DUAL BAND POWER AMPLIFIER
MIRAGE BD-35 DUAL BAND POWER AMPLIFIER INTRODUCTION: The Mirage BD-35 is a 45/35 watt dual band power amplifier for use with today's dual band handie talkies operating in the 144/440MHz bands. We have
More informationGPS10RBN - 10 MHz, GPS Disciplined Rubidium Frequency Standard
GPS10RBN - 10 MHz, GPS Disciplined Rubidium Standard Completely self-contained unit. No extra P.C needed. Full information available via LCD. Rubidium Oscillator locked to GPS satellite signal. Accuracy
More informationWARNING: DO NOT PROCEED WITHOUT READING THIS PAGE.
WARNING: DO NOT PROCEED WITHOUT READING THIS PAGE. The B-1030-G produces at least 300 watts of VHF R.F. power and is not to be taken lightly. Severe R.W. burns can be sustained at this power level! Power
More information3 T856/857 Initial Tuning & Adjustment
M850-00 T856/857 Initial Tuning & Adjustment C3.1 3 T856/857 Initial Tuning & Adjustment The following section describes the full tuning and adjustment procedure and provides information on: channel programming
More informationWARNING: DO NOT PROCEED WITHOUT READING THIS PAGE.
WARNING: DO NOT PROCEED WITHOUT READING THIS PAGE. The B-2530-G produces at least 300 watts of VHF R.F. power and is not to be taken lightly. Severe R.W. burns can be sustained at this power level! Power
More informationSR3400 Base Station Module Configuration and Use Series-2 Cards Only
SR3400 Base Station Module Configuration and Use Series-2 Cards Only A.W. Communication Systems Ltd Crook Barn, The Crook Rowel Town, Carlisle Cumbria Telephone (44) 1697-748777 Fax (44) 1697-748778 www.toneremote.com
More informationAUTOTUNE USER GUIDE. R8000 Series Communications Systems Analyzer
R8000 Series Communications Systems Analyzer AUTOTUNE USER GUIDE Portable Radios Motorola APX 2000 Motorola APX 4000 Motorola APX 6000 Motorola APX 7000 Mobile Radios Motorola APX 2500 Motorola APX 4500
More informationFM TRANSMITTERS TESTS
FM TRANSMITTERS TESTS - FACTORY TESTS - SITE TESTS Page 1 of 11 I. FACTORY TEST (on dummy load) TX s.n... Exciter no...(s.n...) Date... Page 2 of 11 1.PERFORMANCE A) OPERATING FREQUENCY Carrier stability:
More information500W X-Band, 1:2 Redundant System in the 4RU chassis, with N+1 redundant power supplies
400W, 1:1 Redundant System in the 4RU chassis, with optional N+1 redundant power supplies DESCRIPTION 500W, 1:2 Redundant System in the 4RU chassis, with N+1 redundant power supplies 200W 1:1 Redundant
More informationCommercial Analogue Series VX-450, VX-4600 and VXR-9000
Commercial Analogue Series VX-450, VX-4600 and VXR-9000 Meets the following standards: AS/NZS4295, ISO9001 and ISO4001 Commercial Analogue Series VX-450, VX-4600 and VXR-9000 Durable on-the-job responsiveness
More informationAppendix G: IFR 8800 Test Procedures MAINTENANCE GUIDE.
Appendix G: IFR 8800 Test Procedures MAINTENANCE GUIDE www.codanradio.com MAINTENANCE GUIDE MT-4E ANALOG & P25 DIGITAL RADIO SYSTEMS Contents Appendix G: IFR 8800 Test Procedures...1 MT-4E Testing with
More informationMAINTENANCE MANUAL TRANSMITTER/RECEIVER BOARD CMN-234A/B FOR MLSU141 & MLSU241 UHF MOBILE RADIO TABLE OF CONTENTS
MAINTENANCE MANUAL TRANSMITTER/RECEIVER BOARD CMN-234A/B FOR MLSU141 & MLSU241 UHF MOBILE RADIO TABLE OF CONTENTS DESCRIPTION... 2 CIRCUIT ANALYSIS... 2 TRANSMITTER... 2 9-Voft Regulator... 2 Exciter...
More informationMastr III P25 Base Station Transmitter Tune-up Procedure
Mastr III P25 Base Station Transmitter Tune-up Procedure 1. Overview The Mastr III Base Station transmitter alignment is performed in several steps. First, the Transmit Synthesizer module is aligned to
More information500W X-Band, 1:2 Redundant System in the 4RU chassis, with N+1 redundant power supplies
400W, 1:1 Redundant System in the 4RU chassis, with optional N+1 redundant power supplies DESCRIPTION 500W, 1:2 Redundant System in the 4RU chassis, with N+1 redundant power supplies 200W 1:1 Redundant
More informationInstruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46
Instruction Kit GT 60C GT 125C MIXER AMPLIFIER GROMMES-PRECISION 1-800-SINCE-46 www.grommesprecision.com Thank you for purchasing from Grommes~Precision! Grommes~Precision and its commercial audio division,
More information433MHz LRS Adjustable TX/RX Set 100mW-2000mW
433MHz LRS Adjustable TX/RX Set 100mW-2000mW 433 Transmitter ports: GND TX (For software update: connect to USB RX) RX (For software update: connect to USB TX) PWM input (connect to 2.4GHz radio controller,
More informationScalable Ionospheric Analyser SIA 24/6
Scalable Ionospheric Analyser SIA 24/6 Technical Overview Functional description The ATRAD Scalable Ionospheric Analyser SIA24/6 is designed to observe ionospheric irregularities and their drift in the
More informationPlease fill out each section of this questionnaire
2012 Questionnaire Please fill out each section of this questionnaire Date: PROJECT TEAM LEADER: Regional Sales Manager: Manufacturer Representative: Company Name: Account #: Contact person: Phone number:
More informationLBI-38808B. Maintenance Manual EDACS UTILITY PROGRAMMING
LBI-38808B Maintenance Manual EDACS UTILITY PROGRAMMING NOTICE! Repairs to this equipment should be made only by an authorized service technician or facility designated by the supplier. Any repairs, alterations
More informationPC Tune PC Tune Test Procedures for 5100 Series Portable Radios
PC Tune PC Tune Test Procedures for 5100 Series Portable Radios Part Number 002-9998-6513014 August 2008 Copyright 2006, 2007, 2008 by EFJohnson Technologies The EFJohnson Technologies logo, PC Configure,
More informationLava LP-4011-E P1 P2 USER MANUAL
Lava LP-4011-E P1 P2 USER MANUAL Introduction Thank you for purchasing Lava LP-4011-E. Lava LP-4011-E is a PMR-product (Private Mobile Radio) that lets you talk to as many people you wish, as often as
More informationAPX Mobile and Portable Automated Test and Alignment
APX Mobile and Portable Automated Test and Alignment Software Updates First things first! Be sure to check that you are running the latest software versions for the 8800SX and its applications. Visit the
More informationGPS10R - 10 MHz, GPS Disciplined, Rubidium Frequency Standards
GPS10R - 10 MHz, GPS Disciplined, Rubidium Standards Key Features Completely self-contained units. No extra P.C Multiple 10 MHz Outputs plus other outputs needed. Full information available via LCD. RS232
More informationVHF/AM BASE STATIONS MODEL TiL-91-DE/8.33
VHF/AM BASE STATIONS MODEL TiL-91-DE/8.33 7 WATT SYSTEM NO. 920607, Opt.8.33 (TBS-150/8.33) 15 WATT SYSTEM NO. 910815, Opt.8.33 (TBS-250/8.33) 25 WATT SYSTEM NO. 910825, Opt.8.33 (TBS-350/8.33) Installation
More informationModel 1791 VHF Radio User's Manual
Model 79 VHF Radio User's Manual ALL WEATHER INC 65 NATIONAL DRIVE SACRAMENTO, CA 95834 WWW.ALWEATHERINC.COM 79 VHF RADIO USER'S MANUAL CONTENTS INTRODUCTION... Description... Transmitter Module... Power
More informationMIRAGE BD-38-G DUAL BAND POWER AMPLIFIER
MIRAGE BD-38-G DUAL BAND POWER AMPLIFIER MIRAGE BD-38-G Dual Band Amplifier INTRODUCTION: The Mirage BD-38-G is a 80/60 watt dual band power amplifier for use with today's dual band handie talkies operating
More informationQ-Tech. Q-Tech Commercial Series QTA 1360P/1480P Power Amplifiers. User Manual
Q-Tech Power Amplifiers WARNING THIS APPLIANCE MUST BE EARTHED General Installation DO NOT run unbalanced high impedance microphone cables near mains, data, telephone or 70/100V line cables. DO NOT run
More informationOPERATOR S MANUAL KYODO WEST MODEL KG506 FULL-DUPLEX MOBILE. Preliminary
OPERATOR S MANUAL KYODO WEST MODEL KG506 FULL-DUPLEX MOBILE Preliminary 1.0 INTRODUCTION Thank you for purchasing the KYODO WEST MODEL KG506 Full-Duplex Mobile Radio. This manual contains information to
More informationPLUG N PLAY WATT DIGITAL FM TRANSMITTER. April, 2002 IM No
PLUG N PLAY 1000 1000 WATT DIGITAL FM TRANSMITTER April, 2002 IM No. 597 9972 OPERATION/FEATURE PROGRAMMING. The PNP 1000 allows the user to select many types of different operating parameters and features.
More informationThe New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived
The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived FEATURES Output Power levels of: 8.0 kw in C-Band 6.6 kw in X-Band.5 kw in Ku-Band No Active Switching-All Passive Power
More informationALWAYS ATTACH THE SAFETY ROPE TO A STABLE SUPPORT BEFORE ATTEMPTING TO ATTACH THE UNIVERSAL MOUNT TO A WINDOW FRAME OR RAIL.
MFJ-1623 Introduction The MFJ-1623 was designed to provide portable or permanent HF communications on 30 through 10 meters and VHF on 6 meters. The universal mount design allows the user to install the
More information1140LA Broadband Power Amplifier
1140LA Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with
More informationTECHNICAL NOTES. MT-4 Radio Systems. TN247 VR-4E VHF MT-4E Receiver. Specifications. Models Available. Receiver Operating Frequency
MADE IN CANADA TN247 VR-4E VHF MT-4E Receiver USB CNTL BUS A D RECEIVER FREQUENCY (MHz) SQ. DISABLE NORM OFF REF IN RF IN The VR-4E VHF receiver is an FM radio module capable of analog operation in 12.5
More informationDRC 3500 Versatile Ka-Band Transceiver
DRC 3500 Key Features: Flexible Polarisation: RHCP/ LHCP and cross/co-polar 2 GHz operation by switchable sub-bands Optimised, integrated Feed-chain for highest EIRP and G/T True 5 Watt P1dB at the Feed
More informationMaintenance Manual. ORION UHF (Dual Bandwidth) SCAN AND SYSTEM MOBILE RADIO. ericssonz LBI TABLE OF CONTENTS
Maintenance Manual ORION UHF (Dual Bandwidth) SCAN AND SYSTEM MOBILE RADIO TABLE OF CONTENTS Synthesizer/Receiver/Exciter....... LBI-39163 Power Amplifier.............. LBI-39164 PA Interface................
More informationModel 7000 Low Noise Differential Preamplifier
Model 7000 Low Noise Differential Preamplifier Operating Manual Service and Warranty Krohn-Hite Instruments are designed and manufactured in accordance with sound engineering practices and should give
More informationOperation Manual. SlJPER ST AR Channel Mobile 5-Mode Transceiver -----~- --:.. KTSS200NXX ,, I
Operation Manual!.,, SlJPER ST AR 2000 200 Channel Mobile 5-Mode Transceiver -----~- --:.. KTSS200NXX General Description l Frequency/Channel Chart The Super Star -2000 is a combination transmitter-receiver
More informationAUTOTUNE USER GUIDE. R8000 Series Communications System Analyzer. Motorola MOTOTRBO Portable Motorola MOTOTRBO Mobile
R8000 Series Communications System Analyzer AUTOTUNE USER GUIDE Motorola MOTOTRBO Portable Motorola MOTOTRBO Mobile Freedom Communication Technologies 2002 Synergy Blvd, Suite 200 Kilgore, Texas 75662
More informationWARNING! IMPORTANT NOTICE
WARNING! IMPORTANT NOTICE FCC type acceptance requirments prohibit sales of amplifiers operating below 144 MHz with internal RF sensing circuits that place the amplifier in a transmit mode. Because of
More information1.0 Introduction. Related Products and Documentation
Quick Start t Guide ER450 Data Radio 1.0 Introduction Welcome to the Quick Start Guide for the ER450 Data Radio. This guide provides step-by-step instructions, with simple explanations to get you up-and-running.
More informationTactical Communication Products: RT-2000 Remote Mounted Transceiver
PRODUCT DESCRIPTION s Single or Dual, Analog/Digital, P-25 Transceivers VHF-Hi, UHF, 800, 700/800 MHz bands The Wulfsberg RT-2000 is a FM Tactical transceiver that incorporates one or two transceiver modules
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION A.M. BROADCAST TRANSMITTER SENDER AM 3000 SS June 2001-1- Rev. B TRANSMITTER CHARACTERISTICS 1. BASIC OFFER The basic offer includes: One AM3000SS A.M. Medium Wave Solid State Broadcast
More informationVHF/AM SINGLE CHANNEL TRANSCEIVER Model TiL-92-SC (TSC-4100/4200/4300)
VHF/AM SINGLE CHANNEL TRANSCEIVER Model TiL-92-SC (TSC-4100/4200/4300) 25 WATT TRANSCEIVER P/N 921018-1 (TSC-4100) 15 WATT TRANSCEIVER P/N 921018-2 (TSC-4200) LOW POWER TRANSCEIVER P/N 921018-3 (TSC-4300)
More informationIntroduction LOADING COIL COUNTERPOISE ATTACHMENT ANTENNA ATTACHMENT. Figure 1: MFJ-1625 Window/Balcony Mount Antenna
Introduction MFJ-1625 The MFJ-1625 is a 200 Watt antenna tuner that was designed to provide portable or permanent HF communications on 80 through 10 meters and VHF on 6 meters. The universal mount design
More informationMirage B-310-G FEATURES
Mirage B-310-G Mirage B-310-G Instruction Manual The Mirage B-310-G is a VHF power amplifier designed for the 144-148 MHz band. New features make it the most useful and versatile amplifier available for
More informationMaintenance Manual TRANSMITTER/RECEIVER BOARD CMN-233 FOR MLSH041
Maintenance Manual TRANSMITTER/RECEIVER BOARD CMN-233 FOR MLSH041 TABLE OF CONTENTS Page DESCRIPTION... 2 CIRCUIT ANALYSIS... 2 Transmitter... 2 9-volt Regulator... 2 Exciter... 2 40-Watt PA... 2 Antenna
More informationCS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL
CS-200 PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 Operation and Service Manual Page 2 Manufactured by: LINCAST INTERNATIONAL PTY. LTD. 2/3 Sir Laurence Drive
More informationCellular (850 Band) DAS. Tray with Independent Control. General Information. Key Features: Tel: Fax:
Cellular (850 Band) DAS Interface Tray with Independent Control Tel: 201-342-3338 www.cciproducts.com General Information CCI s Cellular Band DAS Interface Tray with Independent Control provides an integrated,
More informationREAD THIS BEFORE ATTEMPTING TO COMBINE
HANDBOOK FM SERIES 2000W POWER COMBINER READ THIS BEFORE ATTEMPTING TO COMBINE 4 s PTEK Contents Theory of operation...2 Specifications...3 Safety Notice...4 Rear Panel Layout...5 Installation...8 Schematic
More informationOUR MISSION: TO PROVIDE HIGH QUALITY PRODUCTS, TECHNICAL EXCELLENCE & PRACTICAL ENGINEERING AT AN ECONOMICAL PRICE
Practical & Compact EMR Corp. Systems Solutions for all LMR & PMR applications offering the most practical approach to full duplex combining in mobile and base station applications. These are single antenna
More informationMidland 248XL I NSTRUCTION GUI DE
Midland 248XL I NSTRUCTION GUI DE INDEX Introduction...2 Function and location of the controls...3 Installation...7 Power supply...7 Installing an antenna...7 How to use your Midland 248XL...8 Frequency
More informationComm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems
Product Catalog 2014 Condensed Version INNOVATIVE CIRCUIT TECHNOLOGY LTD. ICT has been providing DC power conversion products since 1986 for two-way wireless communications, fixed wireless broadband and
More informationEMR CORPORATION N. 25th Avenue Phoenix, Arizona Toll Free: Tel: (623) Fax: (623)
Practical & Compact EMR Corp. Systems Solutions for all LMR & PMR applications offering the most practical approach to full duplex combining in mobile and base station applications. These are single antenna
More informationTOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A
Operation Instruction Manual TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A Features General Description 1 6-channel mixer preamplifier 2 Wide frequency response; 20 20,000Hz, ±1dB 3 Low distortion and noise
More informationMirage B-320-G FEATURES
Mirage B-320-G The Mirage B-320-G is a VHF power amplifier designed for 2 meters covering 144-148 MHz. The Hi and Lo input selector switch makes this amp useable for both handheld and mobile transceivers.
More informationUHF/450MHz Band 100W Power Amplifier
Instruction Manual UHF/450MHz Band 100W Power Amplifier Model PA-100U-5 TOPTEK FEATURES PA-100U-5 is 2-stage UHF power amplifier, capable of delivering 100Watt RF output from less then 2Watt of drive power.
More informationHR1200. Version 1.00 ATIM RADIOCOMMUNICATION 1/11
HR1200 Version 1.00 ATIM RADIOCOMMUNICATION 1/11 Contact Information ATIM RADIOCOMMUNICATION Les guillets 38250 Villard de Lans France Tel : +33 (0)4 76 95 50 65 Fax: +33 (0)4 76 95 50 64 Web : www.atim.com
More informationA 500 Broadband Power Amplifier
A 500 Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with
More informationVHF/AM SINGLE CHANNEL TRANSCEIVER MODEL TiL-92-SC (TSC-4100/4200/4300)
VHF/AM SINGLE CHANNEL TRANSCEIVER MODEL TiL-92-SC (TSC-4/42/43) 25 WATT TRANSCEIVER P/N 928- (TSC-4) 5 WATT TRANSCEIVER P/N 928-2 (TSC-42) 7 WATT TRANSCEIVER P/N 928-3 (TSC-43) Installation and Operating
More informationCat. No OWNER S MANUAL. HTX-212 Two-Meter Mobile Transceiver. Please read before using this transceiver.
19-1125.fm Page 1 Tuesday, August 3, 1999 9:47 AM Cat. No. 19-1125 OWNER S MANUAL HTX-212 Two-Meter Mobile Transceiver Please read before using this transceiver. 19-1125.fm Page 2 Tuesday, August 3, 1999
More informationLT-800 Stationary Transmitter
LT-800 Stationary Transmitter Configuration Stationary FM Transmitter (72 MHz) Stationary FM Transmitter (216 MHz) Stationary FM Transmitter (863 MHz) Thanks to its outstanding audio quality, the Listen
More information7RU SSPA Chassis. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End
FEATURES DESCRIPTION 7RU SSPA Chassis Teledyne Paradise Datacom s 7RU Indoor, High Power Rack Mount series of SSPAs represent the industry s highest power density and most reliable high power amplifier
More informationTB9300 Base Station/Repeater Specifications Manual
TB9300 Base Station/Repeater Specifications Manual MBC-00009-07 Issue 7 July 2015 Contact Information Tait Communications Corporate Head Office Tait Limited P.O. Box 1645 Christchurch New Zealand For the
More informationAssembly Manual. Mobile Communications ANTENNA SYSTEMS LBI ERICSSONZM ERICSSONZM
ERICSSONZM LBI-38983 Mobile Communications ANTENNA SYSTEMS ERICSSONZM Ericsson GE Mobile Communications Inc. Mountain View Road Lynchburg Virginia 24502 Printed in U.S.A. Assembly Manual LBI-38983 TABLE
More informationInstallation & Service Manual
869-894 MHz Installation & Service Manual Model SCA 9321-30C Single-Channel Cellular Amplifier 044-xxxxx Rev.A February 2003 2003 Powerwave Technologies Incorporated. All rights reserved. Powerwave Technologies,
More informationBasic Transceiver tests with the 8800S
The most important thing we build is trust ADVANCED ELECTRONIC SOLUTIONS AVIATION SERVICES COMMUNICATIONS AND CONNECTIVITY MISSION SYSTEMS Basic Transceiver tests with the 8800S Basic Interconnects Interconnect
More informationPhase Combined Systems
100W Ku-Band 1:2 Phase Combined SSPA System with FPRC-1200 Controller 1 kw C-Band, 1:1 Phase Combined High Power Outdoor SSPA System FEATURES 125W Ku-Band 1:1 Phase Combined SSPB System with FPRC-1100
More informationReceiver Adjustments
! -8-4!5 This Section details procedures for tuning and adjustment of T2000 series II radios. This is normally only required during product manufacture or after major servicing. The following topics are
More informationSI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5
SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5 Phone: (905) 564-0801 Fax: (905) 564-0806 www.telecor.com E:\T2-108\T2-M108-ABC\T2-M108-B.doc/AD
More information2006 MFJ ENTERPRISES, INC.
Model MFJ-842 INSTRUCTION MANUAL CAUTION: Read All Instructions Before Operating Equipment MFJ ENTERPRISES, INC. 300 Industrial Park Road Starkville, MS 39759 USA Tel: 662-323-5869 Fax: 662-323-6551 VERSION
More informationRemote Control Extender AUDIO / VIDEO DEVICES EXTENDING SYSTEM
Remote Control Extender AUDIO / VIDEO DEVICES EXTENDING SYSTEM MODEL NO.: AWX 701-A/AWX 701-B/AWX 701-C OPERATION MANUAL Remote Control Extender AUDIO / VIDEO DEVICES EXTENDING SYSTEM MODEL NO.: AWX 701-A/AWX
More informationMaintenance Manual INTERNAL BATTERY STANDBY CHARGER OPTION BC01 (9669), 9670 AND 9771 (FOR MASTR II STATIONS) Mobile Communications LBI-30869L
L Mobile Communications INTERNAL BATTERY STANDBY CHARGER OPTION BC01 (9669), 9670 AND 9771 (FOR MASTR II STATIONS) Printed in U.S.A. Maintenance Manual TABLE OF CONTENTS Page DESCRIPTION...................................................
More informationX-Band Redundant LNA Systems
X-Band Redundant LNA Systems LRX-1000 Series Introduction Redundant LNA systems minimize system downtime due to LNA failure by providing a spare LNA and an automatic means of switching to the spare upon
More informationSUBELEMENT T4. Amateur radio practices and station set up. 2 Exam Questions - 2 Groups
SUBELEMENT T4 Amateur radio practices and station set up 2 Exam Questions - 2 Groups 1 T4A Station setup: connecting microphones; reducing unwanted emissions; power source; connecting a computer; RF grounding;
More informationVHF/AM BASE STATIONS MODEL TiL-90-6R
VHF/AM BASE STATIONS MODEL TiL-9-6R 7 WATT SYSTEM NO. 9277 (TBS-) 5 WATT SYSTEM NO. 995 (TBS-2) 25 WATT SYSTEM NO. 9925 (TBS-3) Installation and Operating Instructions Til Document No. 92RE23 Rev. E Revised
More informationHMC-T2220B. Portable & Battery Operated! Portable Synthesized Signal Generator, 10 MHz to 20 GHz. Instrumentation Product Support at
Portable, 10 MHz to 20 GHz Portable & Battery Operated! 78-250-3343 tel 78-250-3373 fax Battery Operated 20 GHz Signal Generator! The is a battery powered, portable test equipment solution designed to
More informationFCC ID: AXI IC: 10239A Alignment
Introduction The VX-261 is carefully aligned at the factory for the specified performance across the frequency range specified for each version. Realignment should therefore not be necessary except in
More information300W C-Band Second Generation 3RU SSPA Chassis with 1RU N+1 Power Supply
300W C-Band Second Generation 3RU SSPA Chassis with 1RU N+1 Power Supply Teledyne Paradise Datacom s Indoor 3RU Solid State Power Amplifiers represent the latest in High Power Microwave Amplifier Technology.
More information