NEW. The new Centrix 2.0 sets the standard for testing, diagnosis and fault location of power cables.

Size: px
Start display at page:

Download "NEW. The new Centrix 2.0 sets the standard for testing, diagnosis and fault location of power cables."

Transcription

1 The new Centrix 2.0 sets the standard for testing, diagnosis and fault location of power cables. NEW Intuitive easygo operation using a touch display Li-ion battery-power supply for the measurement system Highest level of safety standard with SafeDischarge technology Remote control of important system functions Cable diagnosis with 50 Hz slope technology Breakdown phase detection for three-phase cable testing

2 Centrix 2.0 the most innovative product from Megger Centrix 2.0 is the world s most modern and powerful cable test van system for fast, easy and gentle fault location up to 33 kv. Equipped with the latest generation of cable diagnostics in conjunction with powerful VLF testing technology, Centrix 2.0 makes it possible to perform standard-compliant cable testing with accompanying partial discharge diagnosis. A unique operating concept with automatic measurement sequences using a touch display or JogDial simplifies operation considerably and allows faults to be located quickly, even for inexperienced users. Centrix 2.0 is available in 1-phase or 3-phase versions. 02 Centrix 2.0

3 10 good reasons for Centrix 2.0 Centrix 2.0 sets new standards regarding user friendliness and performance: System control based on Linux for the highest level of stability and security for the future Intuitive easygo operation using the 21.5 touch display and JogDiall Step-by-step operator guidance for inexperienced users Automatic storage and data recording in the history database Decay plus double impulse procedure up to 80 kv ARM live burning Highest level of safety standard with SafeDischarge technology Simultaneous inspection and diagnosis with new 50 Hz slope technology Li-ion battery-power supply for the measurement system Remote control of important system functions for fault location that is gentle to the cables Test van concepts from Megger tailored to the specifications of the customer Centrix

4 System control made simple Centrix 2.0 is operated either by touch display or JogDial. A powerful computer with a 21.5 touch display and integrated recovery system and separate hardware storage for data and programs ensure secure and stable operation over the entire service life of the measuring system. The Linux operating system is completely maintenance free. No viruses, no defragmenting, no expensive antivirus programs and all completely free and without the need for licenses. ion rat e op Kn Touch dis pla y Strict separation of system control and office application along with graphic information systems (GIS) ensure optima system stability and security. On an optional additional monitor, office applications, the database software or the GeoMap software can be displayed. ob 04 e op on r a ti Centrix 2.0

5 Centrix 2.0 thinks ahead The system permanently determines the optimal measurement parameters for the corresponding operating mode. The next, logical operating step is automatically preselected by the system and the user only needs to confirm it, simply and directly! If necessary, fine adjustments can be made manually at any time. Reduction of the operating elements to a minimum provides optimum operating comfort for specialists. In addition, inexperienced users can also quickly locate cable faults with a high degree of accuracy. Automatic data recording All measurements are automatically saved as a database entry. This ensures that no measurement results are lost. Comments can be added to the measurements using an on-screen keyboard. A freely definable input mask makes it possible to adapt to the internal documentation system of each cable operator. Results can be printed immediately or saved as a PDF file to a memory stick using the USB port. Printers can also be connected using the USB port. Core specifications for cable identification Card with cable routing and fault position Cable data Cable number A11 Location Baunach U o [kv rms] 6 Cable type Mixed cable run A Station A Name B08 Station B Name A19 Substation Air isolated Manufacturer ABB Terminator Plug on Substation Air isolated Manufacturer ABB Terminator Heat shrink B Cable overview PE NKBY NKBY PE L1 L2 220 m L3 8 m 322 m 320 m 10m B08 Cable lenght: 660 m A19 Graphic overview of all relevant information and results Centrix

6 Unique technologies that inspire Pre-location Low-resistance cable faults, breaks or the cable lengths are determined with the integrated pulse reflectometer (Teleflex ). Teleflex VX the most powerful reflectometer worldwide When using the reflection measurements, intelligent algorithms determine the necessary setting parameters and make possible Automatic configuration of the measurement range Automatic amplification control Automatic measurement of the cable end Automatic measurement of the fault location IFL IFL mode is used for intermittent faults. Using an envelope, even small changes in the impedance curve can be clearly shown. ICE / decay With the proven current pulse method (ICE) and for the decay travelling vibration method, the measurement of the fault location is also performed automatically. ProRange For ProRange, the gain is adapted based on the distance. Distant joints, fault locations and cable ends are thus better detected. For cables with high attenuation (long cables, moist mass-impregnated cable, crossbonding), this new feature is especially advantageous. without ProRange with ProRange (25%) with ProRange (75%) 930 m 0 km 0,5 km 1,0 km 1,5 km 2,0 km 2,5 km ProRange 06 Centrix 2.0

7 ARM -Plus / Decay-Plus Doppelstoßverfahren Double impulse procedure The patented double impulse procedure was specially developed for high voltage levels and long cables. First, ignition of an arc is performed at the fault location with high voltage. The duration of the resulting arc is extended by a second discharge from a 4 kv pulse module. The arc is thus optimally stabilised and pre-location can thus be performed successfully even in difficult conditions (oil-filled sleeves, humidity in sleeves, long cables) at any time. ARM live burning For ARM live burn down method, the arc burning process can be observed live at the fault location using the reflection measurement. This method is particularly useful for difficult faults in oil-filled joints. ARM -Multishot ARM multi-shot technology makes it possible to display 15 fault patterns per surge pulse. An automated analysis supports the user, immediately displaying the best result a very useful feature, in particular for wet and oil-filled joints. For ARM -Plus: Functional image pulse with 350 V or 1.5 kv Fault pattern pulse with up to 32 kv, additional 4 kv For Decay-Plus: Functional image pulse with 1.5 kv Fault pattern pulse with up to 80 kv, additional 4 kv 930 m Fault pattern Functional image ARM -Multishot images 1,0 km 2,5 km 0 km 0,5 km 1,5 km 2,0 km ARM -Multishot Centrix

8 A wide range of functionality for precise fault location Sheath testing and fault location Sheath testing Sheath fault testing on plastic-insulated medium-voltage and high-voltage cables can be performed up to 20 kv. Pre-location With up to 10 kv output voltage, highly sensitive measurement equipment and a fully automatic measurement procedure, even high-impedance errors in long cables (e.g. offshore) are no problem. Special features: Bi-polar pre-location technology to eliminate thermoelectric offset voltages and galvanic effects (wet joints) Independent of resistances of shield and conductor as well as auxiliary lines and connection clamps Audio frequency output for line tracing 8.44 khz, 15 W (option) Acoustic pinpointing High-impedance and intermittent faults are precisely measured with the help of acoustic location. With controllable voltage levels of 4, 8, 16 and 32 kv, all requirements for low and medium voltage networks are covered. An additional, low-noise and wear-free thyristor surge level with 2 kv is available. Line tracing The audio frequency system controlled by the system is used to locate cable routes and for exact location of cable faults. The powerful audio frequency generators with up to 200 W transmission power support the patented SignalSelect process and the capacitive step voltage process. Pinpoint location Using four voltage levels from 5 to 20 kv at the fault location, Centrix 2.0 generates a safe step potential, potential gradient, which can be located with the help of earthing rods and the ESG NT earth leakage detector. 08 Centrix 2.0

9 Cable testing and diagnostics Insulation test Automatic measurement of insulation resistance and the test specimen capacity with up to 1,000 V test voltage. DC testing DC testing is possible with a voltage of up to 40 kv (optional 80 kv). VLF test according to DIN VDE 0276 The patented technology of the powerful VLF test attachment makes possible large sample capacities. It is thus possible to simultaneously test all three phases on long cable stretches as well without reducing the test frequency. This provides a time saving of two hours. Partial discharge diagnosis The new 50 Hz slope technology makes possible an accompanying PD diagnosis during commissioning testing of MSP cables. The PD diagnosis is performed during polarity reversal (slope) of the test voltage. The rapid change of polarity optimally represents the typical load at 50 Hz mains frequency. With the virtually power-frequency load of the test object, the measurement parameters such as PD inception voltage, frequency and level can be directly compared with the 50 Hz mains frequency. Alternatively, a VLF sinusoidal test attachment is available: For testing and as a voltage generator for the optional TanDelta diagnostics system (for assessment of age-related condition of MSP cables). Breakdown phase detection for three-phase testing With simultaneous measurement of all three phases, it is possible to immediately display the phase on which a breakdown occurred. This saves time and protects the cable. Unique testing and diagnostics system: TDM 45 Three voltage shapes in one device VLF sin wave tandelta diagnosis and Monitored Withstand Test, PD diagnosis on short cables VLF CR (50 Hz Slope) Commissioning testing with accompanying PD diagnosis at high test power DAC (Damped AC) non-destructive PD diagnosis on cables that have aged Centrix

10 Other additional equipment Self-contained power supply Synchronous generator 7 kva Suitable vehicle with auxiliary drive necessary. Travel power Electronic generator 5 KVA. Battery power Battery-operated self-contained power supply of the measurement system with lithium-ion batteries, charge electronics and display unit. Safety An essential part of Centrix 2.0 is the safety system, which monitors all safety-relevant parameters in accordance with current standards. The following criteria are monitored: Loop resistance: System earth to station earth, auxiliary earth to station earth Step voltage: Earth to the vehicle chassis Fast ramp voltages Rear door switch Safety key switch Internal/external emergency switch (EN 50191) Separation of operation and protective earth in connection with an isolating transformer ensures safe earthing conditions. SafeDischarge technology A unique feature is the high level of safety provided by a controlled forced discharge of all system components when an emergency stop is performed or a mains failure occurs. The energy stored in the system is thus no longer discharged into the cable. Remote control Important functions can be controlled remotely. This makes it possible to trigger an emergency shutdown of the system in case of danger, for example. To reduce the load of the cable due to surge pulses, they can be triggered remotely. 10 Centrix 2.0

11 Cleverly stowed Centrix 2.0 and quickly accessible 11

12 GERMANY / AUSTRIA Megger Dr.-Herbert-Iann-Str. 6 D Baunach Tel. +49 (0) Fax +49 (0) team.dach@megger.com SWITZERLAND Megger Schweiz AG Wallbach 13 CH-5107 Schinznach-Dorf Tel. +41 (0) Fax +41 (0) chanfrage@megger.com CENTRIX_BR_EN_V01.pdf

Centrix 2.0 The world s most modern and powerful cable test van system

Centrix 2.0 The world s most modern and powerful cable test van system The world s most modern and powerful cable test van system Centrix 2.0 The world s most modern and powerful cable test van system Intuitive easygo operation using a touch display System powered by Li-Ion

More information

CITY SERIES. Compact, fully equipped cable fault location, test and diagnostic systems

CITY SERIES. Compact, fully equipped cable fault location, test and diagnostic systems CITY SERIES Compact, fully equipped cable fault location, test and diagnostic systems Tailored to fit to small vehicles Easy operation in restricted spaces Centrally controlled, fully automatic system

More information

Cable test vans and systems

Cable test vans and systems Cable test vans and systems Prepared for anything BAUR s cable fault location and diagnostics systems Would you like to test and assess new installations and existing cable locations efficiently? To rectify

More information

Cable test vans and systems

Cable test vans and systems Cable test vans and systems Prepared for anything BAUR s cable fault location and diagnostics systems Would you like to test and assess new installations and existing cable locations efficiently? To rectify

More information

Cable fault location in power cables. Systematics for cable testing, diagnosis and cable fault location

Cable fault location in power cables. Systematics for cable testing, diagnosis and cable fault location Cable fault location in power cables Systematics for cable testing, diagnosis and cable fault location CABLE JOINTS, CABLE TERMINATIONS, CABLE GLANDS, CABLE CLEATS FEEDER PILLARS, FUSE LINKS, ARC FLASH,

More information

ETL-40V CABLE TEST VAN SYSTEM. tel.: +380 (57) fax: +380 (57) high voltage testing equipment

ETL-40V CABLE TEST VAN SYSTEM.  tel.: +380 (57) fax: +380 (57) high voltage testing equipment ETL-40V CABLE TEST VAN SYSTEM DC cable testing up to 40kV with 300mA max. current Burning up to 20kV / 1A Surge energy up to 2000J Precise pinpointing and fault prelocation Fault location using step voltage

More information

VLF. DAC tandelta. Partial Discharge. Experience the world of Megger electrical testing

VLF. DAC tandelta. Partial Discharge. Experience the world of Megger electrical testing Cable Testing & Diagnostics Solutions for Medium Voltage Networks (1 kv - 36 kv) VLF Partial Discharge DC DAC tandelta Cable Testing Cable Diagnostics? There are two main applications for cable testing:

More information

PHG 70 TD PD / PHG 80 TD PD

PHG 70 TD PD / PHG 80 TD PD PHG 70 TD PD / PHG 80 TD PD BAUR VLF test and diagnostics system Functions Universal test and diagnostics system flexible, modular, extendable Cutting-edge testing and diagnostics technology: VLF truesinus

More information

Equipment for cable fault location, testing and diagnostics

Equipment for cable fault location, testing and diagnostics Equipment for cable fault location, testing and diagnostics The world leader We are the world leader in cable test, diagnostic and fault location solutions. Featuring groundbreaking performance, robustness

More information

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C S O L U T I O N S Y O U R S O U R C E F O R T O P Q U A L I T Y T E S T E Q U I P M E N T w w w. h v t e c h n o l o g i e s. c o m Company

More information

Equipment for cable fault location, testing and diagnostics

Equipment for cable fault location, testing and diagnostics Smart Thump The Smart Thump is the only fault locator with built-in intelligence to interpret the results of the initial test sequence. The Turn & Click rotary button operation allows the user automatically

More information

Cable fault location. The shortcut to locating a fault

Cable fault location. The shortcut to locating a fault Cable fault location The shortcut to locating a fault Reliable cable fault location with BAUR Top quality supply is our utmost concern You want to offer your customers a reliable power supply and to use

More information

Specialists in HV and MV test and diagnostics. Testing in Substations

Specialists in HV and MV test and diagnostics. Testing in Substations Specialists in HV and MV test and diagnostics Testing in Substations Testing in Substations Testing in Substations At 4fores we specialize in the diagnosis and measurement of all types of existing technologies

More information

Test systems made by SebaKMT. Don t stress over tests! SebaKMT has the right answers: reliability, speed, economy.

Test systems made by SebaKMT. Don t stress over tests! SebaKMT has the right answers: reliability, speed, economy. Test systems made by SebaKMT Don t stress over tests! SebaKMT has the right answers: reliability, speed, economy. Know how to do it. And what happens next. Test first and save later Connected to the future

More information

OFFLINE PD DIAGNOSTICS USING SEVERAL EXCITATION VOLTAGES

OFFLINE PD DIAGNOSTICS USING SEVERAL EXCITATION VOLTAGES OFFLINE PD DIAGNOSTICS USING SEVERAL EXCITATION VOLTAGES Hein PUTTER Frank PETZOLD Philipp LEGLER Megger Germany Megger Germany Megger - Germany hein.putter@megger.com frank.petzold@megger.com philipp.legler@megger.com

More information

Investigations on a Combined Resonance/VLF HV Test System Partial Discharge (PD) characteristics at VLF and DAC voltages

Investigations on a Combined Resonance/VLF HV Test System Partial Discharge (PD) characteristics at VLF and DAC voltages Investigations on a Combined Resonance/VLF HV Test System Partial Discharge (PD) characteristics at VLF and DAC voltages F. Petzold, H.T. Putter, D. Götz, H. Schlapp, S. Markalous SebaKMT GmbH Baunach/Radeburg,

More information

Insulating oil testing

Insulating oil testing Insulating oil testing Insulating liquids are an important component of many electrical devices. Highly refined mineral oils, silicone oils, vegetable oils (natural ester) and synthetic ester ensure smooth

More information

Cable testing and diagnostics

Cable testing and diagnostics Cable testing and diagnostics To ensure the flow Cost-optimised maintenance through cable diagnostics The sheath and cable testing supports you in assessing whether a cable system is safe and ready to

More information

Fault location on power cables. Fault location on power cables

Fault location on power cables. Fault location on power cables Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 1. Introduction Fault location on communication and power cables

More information

BEST PRACTICES FOR OFFLINE DIAGNOSIS OF MV CABLES

BEST PRACTICES FOR OFFLINE DIAGNOSIS OF MV CABLES BEST PRACTICES FOR OFFLINE DIAGNOSIS OF MV CABLES HEIN PUTTER Productmanager cable testing and -diagnosis Megger Site Germany 1 13 th Insucon conference 16-18 th Mai 2017, Birmingham, UK Agenda Introduction

More information

EI HIGH VOLTAGE INSULATION TESTING POLICY

EI HIGH VOLTAGE INSULATION TESTING POLICY Network(s): Summary: ENGINEERING INSTRUCTION EI 09-0001 HIGH VOLTAGE INSULATION TESTING POLICY EPN, LPN, SPN This engineering instruction details the policy for the on-site insulation testing of new and

More information

Insulating oil testing

Insulating oil testing Insulating oil testing Insulating liquids are an important component of many electrical devices. Highly refined mineral oils, silicone oils, vegetable oils (natural ester) and synthetic ester ensure smooth

More information

Application guide. Cable fault location in LV, MV and HV underground cable networks. Practical experience. Author: Tobias Neier, Ing.

Application guide. Cable fault location in LV, MV and HV underground cable networks. Practical experience. Author: Tobias Neier, Ing. Application guide Cable fault location in LV, MV and HV underground cable networks Practical experience Author: Tobias Neier, Ing., MBA Content 1. Introduction...5 2. Cable types and their characteristics...6

More information

First South East European Regional CIGRÉ Conference. Portoroz, Slovenia, 7 8 June Cable Fault Location on long HVAC and HVDC Cable Systems 2-13

First South East European Regional CIGRÉ Conference. Portoroz, Slovenia, 7 8 June Cable Fault Location on long HVAC and HVDC Cable Systems 2-13 First South East European Regional CIGRÉ Conference Portoroz, Slovenia, 7 8 June 2016 Location on long HVAC and HVDC Systems 2-13 Dr. Frank Petzold Dominik Nowak Matthias Müller Challenges in cable fault

More information

USING DAMPED AC VOLTAGES

USING DAMPED AC VOLTAGES MODERN & TESTING DIAGNOSIS OF POWER CABLES USING DAMPED AC VOLTAGES BY EDWARD GULSKI AND ROGIER JONGEN, Onsite HV Solutions ag, Switzerland AND RALPH PATTERSON, Power Products & Solutions LLC, United States

More information

Award winning product

Award winning product Award winning product Power cable fault locators Van mountable solutions Pinpointer fault locators Cable locators and route tracers TDRs (Power and Telecom) Insulation testers WWW.MEGGER.COM The word Megger

More information

Field Experiences. Partial Discharge Diagnosis on MV Cables. Philipp Legler. XVI. Szigetelésdiagnosztikai Konferencia (

Field Experiences. Partial Discharge Diagnosis on MV Cables. Philipp Legler. XVI. Szigetelésdiagnosztikai Konferencia ( Field Experiences Partial Discharge Diagnosis on MV Cables Philipp Legler Technical Support Applications Engineer (Megger Site Germany) XVI. Szigetelésdiagnosztikai Konferencia (19. - 20.10.2016, Sümeg)

More information

PD Solutions. On-Line PD Measurement Devices

PD Solutions. On-Line PD Measurement Devices On-Line PD Measurement Devices 1. Longshot Device (see Figure 1) The measurement system applied is based around the wideband (0-400 MHz) HVPD- Longshot partial discharge test unit which utilizes a high-speed

More information

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables 21, rue d Artois, F-75008 PARIS AUCKLAND 2013 http : //www.cigre.org Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables Michael Krüger, Rene Hummel, Stefan Böhler, OMICRON Austria

More information

High Voltage Diagnostics Sarl 4, Rue de Lac CH 1897 Le Bouveret Switzerland

High Voltage Diagnostics Sarl 4, Rue de Lac CH 1897 Le Bouveret Switzerland High Voltage Diagnostics Sarl 4, Rue de Lac CH 1897 Le Bouveret Switzerland Company HV Diagnostics Sarl is a Swiss based company in the field of high voltage test equipment for cable testing and diagnosis.

More information

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY

More information

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology Condition Assessment of High Voltage Insulation in Power System Equipment R.E. James and Q. Su The Institution of Engineering and Technology Contents Preface xi 1 Introduction 1 1.1 Interconnection of

More information

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

GENERATOR TESTING APPLICATION GUIDE.  reliable. precision. GENERATOR TESTING APPLICATION GUIDE www.haefely-hipotronics.com reliable. precision. 2 GENERATOR TESTING CONTENTS Product Line Overview 3 AC Hipot Testing 4 Partial Discharge Measurement 5 DC Hipot Testing

More information

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity.

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity. IEE 16th: Safety at all costs C.A 6115N Electrical installation Insulation RCD Earth Loop Continuity Phase rotation I E C CONFIRMS TO CONFIRMS TO IEC/EN 61557 1010-1 III 300V Cat Cat The most complete

More information

Testing and PD Diagnosis of MV Cable Systems with DAC Voltage Educational Session May St Pete Beach, Fl

Testing and PD Diagnosis of MV Cable Systems with DAC Voltage Educational Session May St Pete Beach, Fl Testing and PD Diagnosis of MV Cable Systems with DAC Voltage Educational Session May 26 2011 St Pete Beach, Fl HDW ELECTRONICS, INC. THE BEST IN CABLE FAULT LOCATING TECHNOLOGY by Henning Oetjen Frank

More information

ECP HV INSULATION TESTING

ECP HV INSULATION TESTING Document Number: ECP 11-0006 Network(s): Summary: All ENGINEERING COMMISSIONING PROCEDURE ECP 11-0006 HV INSULATION TESTING This standard details the policy for the on-site insulation testing of new and

More information

UltraTEV Locator Portable Partial Discharge (PD) investigation system.

UltraTEV Locator Portable Partial Discharge (PD) investigation system. UltraTEV Locator Portable Partial Discharge (PD) investigation system Locates, measures and records PD activity in all substation assets including cables www.eatechnologyusa.com Benefits Locating and measuring

More information

Why partial discharge testing makes good sense

Why partial discharge testing makes good sense Why partial discharge testing makes good sense PD measurement and analysis have proven to be reliable for detecting defects in the insulation system of electrical assets before major damage or a breakdown

More information

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound Africa Utility Week Focus Day 2014 Substation Condition Monitoring Benefits of Ultrasound Agenda Review - Substation Condition Monitoring Electrical discharge Types and origin In switchgear Results/consequences

More information

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

ECP HV INSULATION TESTING

ECP HV INSULATION TESTING Document Number: ECP 11-0006 Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE EPN, LPN, SPN ECP 11-0006 HV INSULATION TESTING This standard details the policy for the on-site insulation testing

More information

CP Cu1. Advanced Test Equipment Rentals ATEC (2832) Multi-purpose coupling unit for CPC 100. Measurement System for

CP Cu1. Advanced Test Equipment Rentals ATEC (2832) Multi-purpose coupling unit for CPC 100. Measurement System for Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) CP Cu1 Multi-purpose coupling unit for CPC 100 Measurement System for Line Impedances and k-factors Mutual Coupling

More information

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related UltraTEV Locator Portable PD (Partial Discharge) investigation system Locates, measures and records PD activity in all substation assets including cables benefits Locating and measuring PD activity to

More information

BY JASON SOUCHAK, Megger

BY JASON SOUCHAK, Megger IMPROVING SYSTEM RELIABILITY WITH OFFLINE PD TESTING BY JASON SOUCHAK, Megger Partial discharge (PD) testing is a new generation of diagnostic testing for medium- and high-voltage underground power cable

More information

CSM High-Voltage Measurement Systems

CSM High-Voltage Measurement Systems CSM High-Voltage Measurement Systems Safe Measurement on High-Voltage Components CSM HV Modules // High-Voltage Safe Measurement Systems Safe Measurement on High-Voltage Components E-mobility: enhancing

More information

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

شركة الوقت للكهرباء والمقاوالت ذ.م.م. CONTRACTING COMPANY W.L.L. is a leading corporate in the United Arab Emirates offering quality services in the field of High Voltage Electrical work 400, 132 & 33 kv and Medium Voltage Power Distribution

More information

Fixed Series Compensation

Fixed Series Compensation Fixed Series Compensation High-reliable turnkey services for fixed series compensation NR Electric Corporation The Fixed Series Compensation (FSC) solution is composed of NR's PCS-9570 FSC control and

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) MPD 500 Partial Discharge Measuring System for Routine Test Applications Partial Discharge Measurement The MPD 500 partial

More information

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers The future of installation testing is here The Fluke 50 Series Multifunction Testers Fluke 50 Series Safer, easier installation testing. The 50 Series testers verify the safety of electrical installations

More information

A New Technology. for Measuring Overhead Line and Cable Impedance Values and the Ground Impedance of Large Substations. Feature

A New Technology. for Measuring Overhead Line and Cable Impedance Values and the Ground Impedance of Large Substations. Feature Feature A New Technology for Measuring Overhead Line and Cable Impedance Values and the Ground Impedance of Large Substations Introduction The knowledge of overhead line and cable impedances is very important

More information

GFL-1000 User Manual Ground Fault Locator

GFL-1000 User Manual Ground Fault Locator GFL-Series User Manual V1.1 GFL-1000 User Manual Ground Fault Locator Contents Contents... 1 1 Declaration of Conformity... 3 2 Introduction... 3 3 Equipment Information... 3 3.1 Safety Precautions...

More information

THE EVOLUTION OF NON-INTRUSIVE PARTIAL DISCHARGE TESTING OF MV SWITCHGEAR

THE EVOLUTION OF NON-INTRUSIVE PARTIAL DISCHARGE TESTING OF MV SWITCHGEAR THE EVOLUTION OF NON-INTRUSIVE PARTIAL DISCHARGE TESTING OF MV SWITCHGEAR Neil DAVIES and Chris LOWSLEY EA Technology Ltd. - United Kingdom Neil.Davies@eatechnology.com INRODUCTION The trend for extending

More information

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet 2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated

More information

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

Power Frequency Withstand Voltage On-site testing of 400 kv GIS Power Frequency Withstand Voltage On-site testing of 400 kv GIS D. Anaraki Ardakani, A. Omidkhoda, M. Solati High Voltage Engineering Center ACECR Tehran, Iran Da_ardakani@yahoo.com Paper Reference Number:

More information

Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators

Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators Surge Generator T-1005(7) For fault location in LT and Control cables. Inbuilt DC high voltage testing up

More information

Mitigating Murphy s Law While Test. Frédéric Dollinger

Mitigating Murphy s Law While Test. Frédéric Dollinger Mitigating Murphy s Law While Test Frédéric Dollinger Curriculum Vitae Frédéric Dollinger HAEFELY HIPOTRONICS factory Basel Switzerland Area Sales & Marketing Manager Dipl. Ing. / M.Sc. Mechatronic Language:

More information

NOVEL METHOD FOR ON-SITE TESTING AND DIAGNOSIS OF TRANSMISSION CABELS UP TO 250KV

NOVEL METHOD FOR ON-SITE TESTING AND DIAGNOSIS OF TRANSMISSION CABELS UP TO 250KV NOVEL METHOD FOR ON-SITE TESTING AND DIAGNOSIS OF TRANSMISSION CABELS UP TO 250KV Paul P. SEITZ, Seitz Instruments AG, (Switzerland), pps@seitz-instruments.ch Ben QUAK, Seitz Instruments AG, (Switzerland),

More information

Power supply CP-E 24/0.75

Power supply CP-E 24/0.75 2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output

More information

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet 2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer

More information

MPD 500. Partial Discharge Measuring System for Routine Test Applications

MPD 500. Partial Discharge Measuring System for Routine Test Applications MPD 500 Partial Discharge Measuring System for Routine Test Applications Partial Discharge Measurement The MPD 500 partial discharge measuring system has been specially designed for providing fast and

More information

portable affordable CDS Series Cable Fault Locators Thumpers - Surge Generators

portable affordable CDS Series Cable Fault Locators Thumpers - Surge Generators portable CDS Series Cable Fault Locators Thumpers - Surge Generators HVI offers the most complete fault locator packages available for primary cable. HVI offers the only VLF Thumper combination ideal for

More information

The future of installation testing is here. The 1650 Series Multifunction Testers

The future of installation testing is here. The 1650 Series Multifunction Testers The future of installation testing is here The 50 Series Multifunction Testers 50 Series Safer, easier installation testing. Robin and Fluke joined forces in 999 to become the largest supplier of hand-held

More information

Practical aspects of PD localization for long length Power Cables

Practical aspects of PD localization for long length Power Cables Practical aspects of PD localization for long length Power Cables M. Wild, S. Tenbohlen University of Stuttgart Stuttgart, Germany manuel.wild@ieh.uni-stuttgart.de E. Gulski, R. Jongen onsite hv technology

More information

PRY-CAM BREAKTHROUGH TECHNOLOGY FOR CONDITION ASSESSMENT AND ASSET MANAGEMENT

PRY-CAM BREAKTHROUGH TECHNOLOGY FOR CONDITION ASSESSMENT AND ASSET MANAGEMENT PRY-CAM BREAKTHROUGH TECHNOLOGY FOR CONDITION ASSESSMENT AND ASSET MANAGEMENT WELCOME TO PRY-CAM A REVOLUTION IN PARTIAL DISCHARGE MANAGEMENT The worlds of partial discharge (PD) measurement, asset management

More information

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14 3-349-813-3 1/9.14 Insulation measurement per EN 61557-2/VDE 413, part 2 Test voltages: 5 V, 1 V, 25 V, 5 V and 1 V Analog display of measured values and limit values Intelligent filter precise and measurement-dependent

More information

FRANEO 800. The next generation for a reliable core and winding diagnosis of power transformers

FRANEO 800. The next generation for a reliable core and winding diagnosis of power transformers FRANEO 800 The next generation for a reliable core and winding diagnosis of power transformers The next generation of power transfor Mechanical or electrical problems in power transformer windings, contacts

More information

Power Cables and their Application

Power Cables and their Application Power Cables and their Application Parti Materials Construction Criteria for Selection Project Planning Laying and Installation Accessories Measuring and Testing Editor: Lothar Heinhold 3rd revised edition,

More information

Pre location: Impulse-Current-Method (ICE)

Pre location: Impulse-Current-Method (ICE) 1 ICE (Impulse current method three phased 2 1.1 Ionisation delay time 2 1.2 DIRECT MODE 2 1.3 Output impedance of the generator 2 Surge generator as impulse source 3 High voltage test set as impulse source

More information

PDL 650. Acoustic PD Fault Localization in High-Voltage Equipment

PDL 650. Acoustic PD Fault Localization in High-Voltage Equipment PDL 650 Acoustic PD Fault Localization in High-Voltage Equipment Identifying Problems within Steel Walls As a result of increased demand for power, high voltage equipment is being subjected to ever greater

More information

Transformer condition assessment with an integrated test van

Transformer condition assessment with an integrated test van Transformer condition assessment with an integrated test van 1 2012 SebaKMT Measuring and locating techniques MADE in GERMANY 2 Testing and Standards for Power Transformers CIGRE CIGRE Brochure 342 (SFRA-FRAX)

More information

Simultaneous Partial Discharge and Tan Delta Measurements: New Technology in Cable Diagnostics

Simultaneous Partial Discharge and Tan Delta Measurements: New Technology in Cable Diagnostics Simultaneous Partial Discharge and Tan Delta Measurements: New Technology in Cable Diagnostics Dominique Bolliger, Ph.D. HV TECHNOLOGIES, Inc. Manassas, VA, USA d.bolliger@hvtechnologies.com Abstract In

More information

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS n Quality made in Germany n Standardized and customized solutions n Turn key projects, all from one hand 0.1-1/1 Product Portfolio Test and Measuring Systems

More information

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime Issued: 5.06.999 Status: 5.06.999 Version: B/09..00 Data subject to change without notice Features Overvoltage and undervoltage protection Single- or three-phase operation High-set overvoltage stage with

More information

Diagnostic testing of cast resin transformers

Diagnostic testing of cast resin transformers Paper of the Month Diagnostic testing of cast resin transformers Author Michael Krüger, OMICRON, Austria michael.krueger@omiconenergy.com Christoph Engelen, OMICRON, Austria christoph.engelen@omicronenergy.com

More information

EE Lecture 14 Wed Feb 8, 2017

EE Lecture 14 Wed Feb 8, 2017 EE 5223 - Lecture 14 Wed Feb 8, 2017 Ongoing List of Topics: URL: http://www.ece.mtu.edu/faculty/bamork/ee5223/index.htm Labs - EE5224 Lab 3 - begins on Tues Feb 14th Term Project - details posted. Limit

More information

HVA SERIES VLF TEST SETS. Hipot Testers HVA Series for VLF (0.1 Hz) testing of MV and HV cables.

HVA SERIES VLF TEST SETS. Hipot Testers HVA Series for VLF (0.1 Hz) testing of MV and HV cables. HVA SERIES VLF TEST SETS Hipot Testers HVA Series for VLF (0.1 Hz) testing of MV and HV cables. INNOVATIVE, RELIABLE, ECONOMICAL HIGH VOLTAGE TESTING FROM b2 HIGH VOLTAGE VLF, DC, cable sheath testing

More information

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

HVI - The World s Source For High Voltage Test Equipment

HVI - The World s Source For High Voltage Test Equipment HVI - The World s Source For High Voltage Test Euipment HVI Products Are Designed to Surpass All Others in Features, Specifications, and Ease in Use The World s Source for High Voltage Test EuipmentMADE

More information

N. TEST TEST DESCRIPTION

N. TEST TEST DESCRIPTION Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities

More information

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring The first Real-Time Protection and Automation platform that can be adapted to a wide variety of applications. While

More information

Partial discharge diagnostics on very long and branched cable circuits

Partial discharge diagnostics on very long and branched cable circuits 11 Nordic Insulation Symposium Stockholm, June 11-13, 2001 Partial discharge diagnostics on very long and branched cable circuits Nico van Schaik, E. Fred Steennis, Wim Boone and Dick M. van Aartrijk KEMA

More information

EPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY

EPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY EPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY EPS AUSTRALIA SERVICES COMPANY OVERVIEW EPS is a recognised company specialising in Electrical, Instrumentation, Structural, Mechanical and

More information

Primary Test Manager (PTM) Testing and management software for primary assets

Primary Test Manager (PTM) Testing and management software for primary assets Primary Test Manager (PTM) Testing and management software for primary assets Asset diagnostics now easier than ever How well do you know your assets? High-voltage assets are subjected to aging and wear

More information

STANDARD TECHNICAL SPECIFICATION FOR UNDERGROUND CABLE FAULT LOCATING EQUIPMENT AND OTHER ACCESSORIES

STANDARD TECHNICAL SPECIFICATION FOR UNDERGROUND CABLE FAULT LOCATING EQUIPMENT AND OTHER ACCESSORIES STANDARD TECHNICAL SPECIFICATION FOR UNDERGROUND CABLE FAULT LOCATING EQUIPMENT AND OTHER ACCESSORIES TECHNICAL PROPOSAL AND SPECIFICATION 1. GENERAL REQUIREMENTS : The cable fault locator shall be capable

More information

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates OMICRON Seminar on Substation Testing and Diagnosis October 23, 2017 Dubai, United Arab Emirates October 24, 2017 Abu Dhabi, United Arab Emirates Time Optimized Substation Asset Testing and Diagnosis Agenda

More information

Partial Discharge, Survey or Monitor?

Partial Discharge, Survey or Monitor? July 2014 Partial Discharge, Survey or Monitor? 24-7 Partial Discharge monitoring is the ultimate tool for finding insulation weaknesses before they fail. Introduction It s well established that Partial

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

EQUIPMENT AND MOBILE LABORATORIES FOR NDT AND DIAGNOSTICS OF UNDERGROUND COMMUNICATION LINES.

EQUIPMENT AND MOBILE LABORATORIES FOR NDT AND DIAGNOSTICS OF UNDERGROUND COMMUNICATION LINES. 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China EQUIPMENT AND MOBILE LABORATORIES FOR NDT AND DIAGNOSTICS OF UNDERGROUND COMMUNICATION LINES. Vasily N. KOLTSOV 1, Yury

More information

MIT510/2, MIT520/2 and MIT1020/2

MIT510/2, MIT520/2 and MIT1020/2 MIT510/2, MIT520/2 and MIT1020/2 Line supply or battery operated Digital/analog backlit display Measurement range to 15 TΩ (MIT510/2 and MIT520/2) and 35 TΩ (MIT1020/2) CAT IV 600 V safety rating Automatic

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

ISOMETER IRDH575. Approvals

ISOMETER IRDH575. Approvals Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation

More information

ELECTRICAL SAFETY TESTERS. Wings for Your Projects. APPLICATION NOTE

ELECTRICAL SAFETY TESTERS. Wings for Your Projects. APPLICATION NOTE APPLICATION NOTE ELECTRICAL SAFETY TESTERS Wings for Your Projects. Four Principal Tests for Evaluating the Safety of Electrical and Electronic Products TOS SERIES ELECTRICAL SAFETY TESTER TOS SERIES SELECTION

More information

Name: Craig Goodwin. Company Name: HV Diagnostics Inc

Name: Craig Goodwin. Company Name: HV Diagnostics Inc Name: Craig Goodwin Company Name: HV Diagnostics Inc Trip Out of Cable Circuit: Over Current, Ground Fault, Differential protection or Fuse blows. Try to establish if the cable has in fact failed or has

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer IN 1000-S N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)

More information

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge The University of New South Wales School of Electrical Engineering and Telecommunications High Voltage Systems ELEC9712 Appendix Partial Discharge Content Introduction Quantities measured Test circuits

More information

proton beam onto the screen. The design specifications are listed in Table 1.

proton beam onto the screen. The design specifications are listed in Table 1. The Spallation Neutron Source (SNS) utilizes an electron scanner in the accumulator ring for nondestructive transverse profiling of the proton beam. The electron scanner consists of a high voltage pulse

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) The toolbox for substation 3-phase testing Three currents and four voltages Stand-alone functionality Rugged and reliable

More information

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Conventional Paper-II-2011 Part-1A

Conventional Paper-II-2011 Part-1A Conventional Paper-II-2011 Part-1A 1(a) (b) (c) (d) (e) (f) (g) (h) The purpose of providing dummy coils in the armature of a DC machine is to: (A) Increase voltage induced (B) Decrease the armature resistance

More information

Multimeter 500CVD21 RTU500 series

Multimeter 500CVD21 RTU500 series Remote Terminal Units - Data sheet Multimeter 500CVD21 RTU500 series CT/VT interface with 4 voltage and 24 current inputs for direct monitoring of 3/4 wire 0 300 V AC (line to earth), 0...500 V AC (phase

More information