ETL-40V CABLE TEST VAN SYSTEM. tel.: +380 (57) fax: +380 (57) high voltage testing equipment

Size: px
Start display at page:

Download "ETL-40V CABLE TEST VAN SYSTEM. tel.: +380 (57) fax: +380 (57) high voltage testing equipment"

Transcription

1 ETL-40V CABLE TEST VAN SYSTEM DC cable testing up to 40kV with 300mA max. current Burning up to 20kV / 1A Surge energy up to 2000J Precise pinpointing and fault prelocation Fault location using step voltage mode Highly reliable and safe operation

2 2 Cable test van system The ETL-40V Vehicle based system ensures efficient non-destructive cable fault location on low to medium voltage cables up to 40kV. The fault location system combines: a surge wave generator a time domain reflectometer an audio frequency generator and a cable fault detector which allows for a variety of cable diagnostics and testing procedures user-friendly interface enables both expert technicians and personnel with little experience in cable fault location to perform effortless testing. The cable testing and fault locating equipment supplied is based on test sets from KEP s product range and may be customized to specific test applications. Hipot and TDR testing The test system supports the most popular cable fault location methods, including thumping (or acoustic method) and the techniques of time domain reflectometry. The surge mode provides DC testing of cable integrity at up to 32kV and surge energy up to 2000J. The standard TDR methods of pulse echo, arc reflection, impulse current and voltage decay ensure accurate cable fault prelocation. Pinpointing Acoustic pinpointing of cable faults is easily achieved with the surge wave generator in conjunction with the P-900 ground microphone. Pinpointing of a sheath fault is delivered either with pulsed DC step-voltage or the burn mode. The modular type of the ETL-40V test system allows the installation of 50W or 200 W audio frequency generators to aid line tracing and cable fault pinpointing. Highly reliable and safe operation A range of the system s safety features includes high voltage interlocks, emergency stop, key switch, and rear door interlock which delivers high levels of safety during operation. All the test sets are equipped with operational, protective and auxiliary earth. The independent GCU-3 module monitors the resistance between operational earth and protective earth, and the voltage between protective and auxiliary earth. In addition, the high safety standards are maintained through the use of the isolating transformer. If the cable under test breaks down, the integrated overcurrent trip will make sure no damage is done to the object being tested.

3 Technical data Cable Test Van System TEST MODE ETL-40V Output DC voltage, kv 0 40 Output DC current, ma BURN MODE Output DC voltage, kv 0 20 Output DC current, ma SURGE MODE Ranges, kv 8 / 16 / 32 Output energy, J 2000 Impulse sequence, s PRELOCATION MODE * Methods Automatic distance measuring CABLE FAULT LOCATION MODE** ** 3 15 or single shot TDR / ICE / Decay / ARC Generator output power, W 50 (200) Operating frequencies***, Hz POWER SUPPLY 491/982/ /1450/ /1024/8928 Input voltage, V 230 Frequency, Hz 50 Power consumption, kva, max 2.5 Ambient operation temperature, С Ambient storage temperature, С Relative air humidity non condensing 3 * See more on p. 4-5 ** See more on p. 6-7 *** It is possible to change the operating frequencies according to the user s request.

4 Time Domain Reflectometer The integrated RIF-9 Time Domain Reflectometer, with its bright, high contrast, high resolution, 10.4-inch TFT touch-screen display, allows straightforward navigation through the system s menus. Alternatively, the reflectometer can be operated with a control knob. The RIF-9 integrates a range of fault prelocation methods. The reflectometer incorporates both RS 485 and USB interfaces. Test measurements are saved in the database and can be processed with the optional PC software. The firmware is easily updated using a USB memory stick. Cable fault prelocation mode CABLE FAULT LOCATION 4 Starting up program Language selection Testing Mode Burning Mode Surge Wave Mode Prelocation Mode Control interface

5 Technical data Time Domain Reflectometer RIF-9 Distance measurement ranges (for velocity of propagation 1.50 or V/2 = 100 m/μs), m Resolution, m: 60 / 120 / 250 / 500 / 1000 / 2000 / 5000 / / / / at velocity of propagation of 1.5 (V/2 = 100 m/μs) 0.5 at velocity of propagation of 1.87 (V/2 = 80.2 m/μs) 0.4 Distance measurement accuracy, % 0.2 Sampling rate, MHz 200 Accuracy of time markers, % up to 0.01 Output impedance range (sampling frequency of 2 Ω), Ω Probe pulse parameters: amplitude, V 45 duration, ns Measurement range of input amplifier gain, db Averaging reflectograms number, pcs 1 64 Setting range of: velocity of propagation velocity of propagation V/2, m/μs Setting discreteness of: velocity of propagation velocity of propagation V/2, m/μs 0.1 Nonvolatile memory capacity of: reflectograms with parameters 1000 data on cable velocity of propagation 500 Voltage on measuring inputs, V, max 50 Display resolution, pixel Power supply and charging: , TFT, touch screen battery voltage, V 12 mimimum operation on full charge, hours, min 6 external power source voltage, V 24 voltage range of external power supply, V Power consumption, V A, max 36 5

6 6 LFG-50 LFG-50 in the set Audio Frequency Systems For the purposes of line tracing and accurate fault location, the ETL 40V integrates the LFG audio frequency system, with either a 50W (LFG-50) or 200W (LFG 200) low frequency generator. The LFG provides automatic load adjustment, single or multi-frequency operation, and overload protection. An audio frequency signal can be transmitted directly or inductively from a built-in antenna or clamps (optional). Operation frequency levels of the following sets: 526Hz, 1024Hz, 8928Hz or 491Hz, 982Hz, 8440Hz and 480Hz, 1450Hz, 9820Hz are preset. Any customs frequencies (400Hz to Hz range) can be added on request. When several cable systems are in close proximity, the LFG allows quick and easy cable identification. The LFG display reads the main test parameters such as the output power, load impedance, and selected frequency. If a load is higher than 1000Ω, the LFG will automatically offer to set the output voltage. If a short occurs or the load impedance is below 0.5Ω, the output overload protection will trip. LFG-200

7 Technical data Low Frequency Generators LFG-50 LFG-200 Output frequencies * (3 sets of 3 frequencies), Hz Multi-frequency mode 491/982/ /1450/ /1024/8928 Output power adjustment range, V A Increment for manual power adjustment, V A Frequency selection Operation modes Impedance matching Impedance matching range, Ω manual continuous, pulsed automatic Output voltage (RMS), V, max Range of measured and indicated parameters: output voltage, V current, A load impedance, Ω phase angle, º 0 90 Voltage, current, impedance measurement accuracy, % 5 Phase angle measurement accuracy, % 10 Modulation type amplitude Pulse frequency, Hz 1 Power supply and battery: battery voltage, V 12 mimimum operation on full charge **, hours, min 1 average recharge time, hours 3 external power source voltage, V Mains power consumption, V A, max Current consumption from external power source (12 V), A, max 8 Weight, kg, max 8 Dimensions, W x H x D, mm, max 366 x 270 x * User-specific frequencies on request. ** Using lower output power or pulsed mode when the Generator is battery-powered helps to significantly conserve the battery life.

8 The Cable Fault Detector (PT-14) is used for cable line location, tracing and depth measurement. Also, using the tracer the user can locate T- and Y-splices, under-surface transformers and test shield integrity. Technical data Cable Fault Detector Operating frequencies, Hz PT / 491 / 526 / 982 / 1024 / 2000 / 2048 / 8440 / 8928 / 9820 / / Bandwidth: RADIO mode, khz ONLINE mode, Hz Sensitivity, μv 1 Track depth measurment error, %, max 5 Dimensions, W x H x D, mm 700 x 300 x 140 Weight, kg, max 2.4 PT-14 8 P-900 Ground Microphone P-900 Complete Set Technical data The ground microphone P-900 should be used with an auxiliary frequency generator of 1024 ± 2 Hz / 2048 ± Hz and no less than 200 W of output power at the load range from 0.5 to 200 Ohms when searching using the inductive method. Ground Microphone P-900 Operating frequency, Hz 1024 / 2048 Sensitivity at highest amplification, µv 20 Sensitivity at lowest amplification, µv 500 Frequency band -3 db, «1024 Hz» mode, Hz 10 Frequency band -3 db, «2048 Hz» mode, Hz 12 Bandwidth in the acoustic mode, Hz Built-in battery parameters 5x1.2 V 2500 mah Mimimum operation on full charge, hours, min 16 Average recharge time, hours 16 Weight with batteries, kg, max 0.65 Dimensions, W x H x D, mm, max 180 x 70 x 120

9 Package contents Cable Test Van System ETL-40V Options Surge Wave Locator Set P-900 Cable drum set, which includes 50m of the following cables: Cable Fault Detector PT-14 HV testing cable 1 set Low Frequency Generator LFG-50 Safety grounding cable 1 set Low Frequency Generator LFG-200 Control grounding cable 1 set Silent Power Generator 2.5 kva Power cable 1 set Operating desk wih drawers for tools Cables for RIF-9 2 sets Additional 230V CEE16 outlets for auxiliary devices connection Isolating Transformer 4 kva 1 Warning lamps (red) for operating condition indication 9 Van Side View Van Top View

Centrix 2.0 The world s most modern and powerful cable test van system

Centrix 2.0 The world s most modern and powerful cable test van system The world s most modern and powerful cable test van system Centrix 2.0 The world s most modern and powerful cable test van system Intuitive easygo operation using a touch display System powered by Li-Ion

More information

NEW. The new Centrix 2.0 sets the standard for testing, diagnosis and fault location of power cables.

NEW. The new Centrix 2.0 sets the standard for testing, diagnosis and fault location of power cables. The new Centrix 2.0 sets the standard for testing, diagnosis and fault location of power cables. NEW Intuitive easygo operation using a touch display Li-ion battery-power supply for the measurement system

More information

Cable test vans and systems

Cable test vans and systems Cable test vans and systems Prepared for anything BAUR s cable fault location and diagnostics systems Would you like to test and assess new installations and existing cable locations efficiently? To rectify

More information

CITY SERIES. Compact, fully equipped cable fault location, test and diagnostic systems

CITY SERIES. Compact, fully equipped cable fault location, test and diagnostic systems CITY SERIES Compact, fully equipped cable fault location, test and diagnostic systems Tailored to fit to small vehicles Easy operation in restricted spaces Centrally controlled, fully automatic system

More information

STANDARD TECHNICAL SPECIFICATION FOR UNDERGROUND CABLE FAULT LOCATING EQUIPMENT AND OTHER ACCESSORIES

STANDARD TECHNICAL SPECIFICATION FOR UNDERGROUND CABLE FAULT LOCATING EQUIPMENT AND OTHER ACCESSORIES STANDARD TECHNICAL SPECIFICATION FOR UNDERGROUND CABLE FAULT LOCATING EQUIPMENT AND OTHER ACCESSORIES TECHNICAL PROPOSAL AND SPECIFICATION 1. GENERAL REQUIREMENTS : The cable fault locator shall be capable

More information

Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators

Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators Surge Generator T-1005(7) For fault location in LT and Control cables. Inbuilt DC high voltage testing up

More information

Cable test vans and systems

Cable test vans and systems Cable test vans and systems Prepared for anything BAUR s cable fault location and diagnostics systems Would you like to test and assess new installations and existing cable locations efficiently? To rectify

More information

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer ShinewayTech CAA-100A cable & antenna analyzer with spectrum analyzer can test DTF/Frequency Return Loss, VSWR, Cable Loss, RF Power and Spectrum.

More information

First South East European Regional CIGRÉ Conference. Portoroz, Slovenia, 7 8 June Cable Fault Location on long HVAC and HVDC Cable Systems 2-13

First South East European Regional CIGRÉ Conference. Portoroz, Slovenia, 7 8 June Cable Fault Location on long HVAC and HVDC Cable Systems 2-13 First South East European Regional CIGRÉ Conference Portoroz, Slovenia, 7 8 June 2016 Location on long HVAC and HVDC Systems 2-13 Dr. Frank Petzold Dominik Nowak Matthias Müller Challenges in cable fault

More information

PHG 70 TD PD / PHG 80 TD PD

PHG 70 TD PD / PHG 80 TD PD PHG 70 TD PD / PHG 80 TD PD BAUR VLF test and diagnostics system Functions Universal test and diagnostics system flexible, modular, extendable Cutting-edge testing and diagnostics technology: VLF truesinus

More information

Award winning product

Award winning product Award winning product Power cable fault locators Van mountable solutions Pinpointer fault locators Cable locators and route tracers TDRs (Power and Telecom) Insulation testers WWW.MEGGER.COM The word Megger

More information

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY

More information

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer ShinewayTech CAA-100A cable & antenna analyzer with spectrum analyzer can test DTF/Frequency Return Loss, VSWR, Cable Loss, RF Power and Spectrum.

More information

General purpose Signal generation and analysis. Well-equipped for field and lab the R&S Spectrum Rider

General purpose Signal generation and analysis. Well-equipped for field and lab the R&S Spectrum Rider General purpose Signal generation and analysis Well-equipped for field and lab the R&S Spectrum Rider 32 The new R&S Spectrum Rider makes spectrum analysis in the field and lab easier, faster and more

More information

MFD900. The most industrial ultrasonic test system for flaw detection and thickness measurements

MFD900. The most industrial ultrasonic test system for flaw detection and thickness measurements MFD900 The most industrial ultrasonic test system for flaw detection and thickness measurements Guaranteed the lowest possible down time over many years. Pure ultrasonic testpower for high speed off- line

More information

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM

More information

Application guide. Cable fault location in LV, MV and HV underground cable networks. Practical experience. Author: Tobias Neier, Ing.

Application guide. Cable fault location in LV, MV and HV underground cable networks. Practical experience. Author: Tobias Neier, Ing. Application guide Cable fault location in LV, MV and HV underground cable networks Practical experience Author: Tobias Neier, Ing., MBA Content 1. Introduction...5 2. Cable types and their characteristics...6

More information

MFD900. The most industrial ultrasonic test system for flaw detection and thickness measurements

MFD900. The most industrial ultrasonic test system for flaw detection and thickness measurements MFD900 The most industrial ultrasonic test system for flaw detection and thickness measurements Guaranteed the lowest possible down time over many years. Pure ultrasonic testpower for high speed off- line

More information

Analyzer Twin. k +49 (0) / (0) / General Agent Germany:

Analyzer Twin. k +49 (0) / (0) / General Agent Germany: Combined Instrument for Quartz and Mechanical Watches This combined measurement and test instrument associates all functions of test equipments for quartz watches and test equipments for mechanical watches.

More information

CAR - TEST - SYSTEM 14

CAR - TEST - SYSTEM 14 CAR - TEST - SYSTEM 14 EMC-Test Equipment for electrical installation of vehicles Acc. to ISO 7637-2, ISO 16750-2 ISO 21848 Rise time variable 1-5µs Pulse Waveforms : #1 1-5/2000µs, 600 V, ISO 1-5/1000µs,

More information

AT-7000 Advanced Wire Tracer

AT-7000 Advanced Wire Tracer AT-7000 Advanced Wire Tracer Wire Tracing Reinvented Get accurate results in minutes with new features and technologies that simplify wire tracing and breaker identification. The s patented Smart Sensor,

More information

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS www. transmille.com 3010A EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last

More information

JD723A/JD724B/JD726A Cable and Antenna Analyzers

JD723A/JD724B/JD726A Cable and Antenna Analyzers COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS JD723A/JD724B/JD726A Cable and Antenna Analyzers Key Features Portable and lightweight handheld instrument. Built in wireless frequency bands as well as the

More information

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related UltraTEV Locator Portable PD (Partial Discharge) investigation system Locates, measures and records PD activity in all substation assets including cables benefits Locating and measuring PD activity to

More information

U1604A Handheld Oscilloscopes, 40 MHz

U1604A Handheld Oscilloscopes, 40 MHz Products & Services Technical Support Buy Industries About Agilent Search: All Test & Measurement Go United States Home >... > Oscilloscopes > U1600A Series handheld oscilloscopes (2 models) > U1604A Handheld

More information

UltraTEV Locator Portable Partial Discharge (PD) investigation system.

UltraTEV Locator Portable Partial Discharge (PD) investigation system. UltraTEV Locator Portable Partial Discharge (PD) investigation system Locates, measures and records PD activity in all substation assets including cables www.eatechnologyusa.com Benefits Locating and measuring

More information

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes United States Home >... > Oscilloscope Accessories > U1600 Series Oscilloscope Accessories > U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes Key Specifications Features Ni-MH Battery Pack,

More information

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR 6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR Power supply It is based upon the latest switch mode power supply technology, offering size reduction (smallest 6 kw available on the market,

More information

HVA SERIES VLF TEST SETS. Hipot Testers HVA Series for VLF (0.1 Hz) testing of MV and HV cables.

HVA SERIES VLF TEST SETS. Hipot Testers HVA Series for VLF (0.1 Hz) testing of MV and HV cables. HVA SERIES VLF TEST SETS Hipot Testers HVA Series for VLF (0.1 Hz) testing of MV and HV cables. INNOVATIVE, RELIABLE, ECONOMICAL HIGH VOLTAGE TESTING FROM b2 HIGH VOLTAGE VLF, DC, cable sheath testing

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 605-S ULTRASTAB I PN = 600 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature

More information

Name: Craig Goodwin. Company Name: HV Diagnostics Inc

Name: Craig Goodwin. Company Name: HV Diagnostics Inc Name: Craig Goodwin Company Name: HV Diagnostics Inc Trip Out of Cable Circuit: Over Current, Ground Fault, Differential protection or Fuse blows. Try to establish if the cable has in fact failed or has

More information

Insulating oil testing

Insulating oil testing Insulating oil testing Insulating liquids are an important component of many electrical devices. Highly refined mineral oils, silicone oils, vegetable oils (natural ester) and synthetic ester ensure smooth

More information

N. TEST TEST DESCRIPTION

N. TEST TEST DESCRIPTION Multi function system for testing substation equipment such as: current, voltage and power transformers, over-current protection relays, energy meters and transducers Primary injection testing capabilities

More information

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power

More information

Transient Data Acquisition System, TAS 4-40 Potential-free measurement of fast rise pulses:

Transient Data Acquisition System, TAS 4-40 Potential-free measurement of fast rise pulses: Transient Data Acquisition System, TAS 4-40 Potential-free measurement of fast rise pulses: High precision measurement of fast rising voltages and currents causes considerable problems in many spheres

More information

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES PERFORMANCES High accuracy High stability Fast transients High inrush current facilities Wide bandwidth Very low distortion Quadrant change without transition Very low output impedance Low noise RS232

More information

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR MODEL 9050 EXTENDED SPECIFICATIONS Ü 50ppm TRANSPORTABLE CALIBRATOR 9050A EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last used up to 20 minutes maximum

More information

HZ530 Near-Field Probe Set

HZ530 Near-Field Probe Set HZ530 Near-Field Probe Set The HZ530 Probe Set consists of three active broadband probes for EMI diagnosis. The probes are designed for connection to a HAMEG spectrum analyzer with input impedance of 50

More information

TEST AND MEASUREMENT EQUIPMENT for the power industry

TEST AND MEASUREMENT EQUIPMENT for the power industry TEST AND MEASUREMENT EQUIPMENT for the power industry Cable test vans Cable fault location High voltage test equipment Measurement equipment High current/circuit breaker test equipment Rubber goods testing

More information

AV3672 Series Vector Network Analyzer

AV3672 Series Vector Network Analyzer AV3672 Series Vector Network Analyzer AV3672A/B/C/D/E (10MHz 13.5 GHz/26.5 GHz/43.5 GHz/50 GHz/67 GHz) Product Overview: AV3672 series vector network analyzer include AV3672A (10MHz 13.5GHz), AV3672B (10MHz

More information

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual. Manual Title: 5502E Getting Started Supplement Issue: 3 Part Number: 4155211 Issue Date: 9/18 Print Date: November 2012 Page Count: 12 Revision/Date: This supplement contains information necessary to ensure

More information

AT RF20 MultiBand Handheld Transceiver

AT RF20 MultiBand Handheld Transceiver AT RF20 MultiBand Handheld Transceiver AT RF20 MultiBand Handheld Transceiver AT RF20 ECCM handheld multiband transceiver with improved resistance to electronic warfare is designated for use at the lowest

More information

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System DRTS-6 Advanced Protection Relay Test Set and Measurement System MULTI-TASKING EQUIPMENT DESIGNED FOR TESTING PROTECTION RELAYS, ENERGY METERS, TRANSDUCERS POWERFUL AND LIGHTWEIGHT HIGH ACCURACY: BETTER

More information

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc. P a g e 1 ST985 TDR Cable Analyzer Instruction Manual Analog Arts Inc. www.analogarts.com P a g e 2 Contents Software Installation... 4 Specifications... 4 Handling Precautions... 4 Operation Instruction...

More information

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc HSI Series Modules Selection Guide HSI Series Modules Single channel High bandwidth - for dynamic signals Isolation (all models Analog signal output (±5 V Single channel modularity For DEWETRON systems

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 205-S ULTRASTAB I PN = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature

More information

CABLE FAULT LOCATING APPLICATION GUIDE. HIGH V O L T A G E T E S T S OLUTION S. reliable. precision.

CABLE FAULT LOCATING APPLICATION GUIDE.  HIGH V O L T A G E T E S T S OLUTION S. reliable. precision. CABLE FAULT LOCATING APPLICATION GUIDE www.hipotronics.com reliable. precision. HIGH V O L T A G E T E S T S OLUTION S 2 CABLE FAULT LOCATING CONTENTS Product Line Overview 3 Vehicle-Mounted Fault Locators

More information

MODEL 9041 EXTENDED SPECIFICATIONS. 25ppm TRANSPORTABLE CALIBRATOR

MODEL 9041 EXTENDED SPECIFICATIONS. 25ppm TRANSPORTABLE CALIBRATOR MODEL 9041 EXTENDED SPECIFICATIONS 25ppm TRANSPORTABLE CALIBRATOR 9041 EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last used up to 20 minutes maximum

More information

Specification for Conducted Emission Test

Specification for Conducted Emission Test 1 of 10 1. EMI Receiver Frequency range 9kHz 7.0 GHz Measurement time per frequency 10 µs to 100 s time sweep, span = 0 Hz - 1 µs to 16000 s Sweep time in steps of 5 % frequency sweep, span 10 Hz - 2.5

More information

Cable fault location. The shortcut to locating a fault

Cable fault location. The shortcut to locating a fault Cable fault location The shortcut to locating a fault Reliable cable fault location with BAUR Top quality supply is our utmost concern You want to offer your customers a reliable power supply and to use

More information

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual. Manual Title: 550A Getting Started Supplement Issue: Part Number: 415509 Issue Date: 9/18 Print Date: November 01 Page Count: 19 Revision/Date: This supplement contains information necessary to ensure

More information

5080A Multi-Product Calibrator

5080A Multi-Product Calibrator 5080A Multi-Product Calibrator Calibration solutions for your analog and digital workload 5080A Multi-Product Calibrator: expanded workload coverage Calibrate analog and digital meters, and much more The

More information

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS PERFORMANCES High accuracy High stability Fast times of transition High inrush current Wide bandwidth Switching from Q1 to Q4 without transition Very low output impedance Ripple & noise superposition Dips

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 200-S ULTRASTAB I PM = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)

More information

Digital Function Generator

Digital Function Generator Digital Function Generator 13654-99 PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 37079 Göttingen Germany Tel. +49 (0) 551 604-0 Fax +49 (0) 551 604-107 E-mail info@phywe.de Operating Instructions

More information

Spectrum Analyzer R&S FS300

Spectrum Analyzer R&S FS300 Spectrum Analyzer R&S FS300 9 khz to 3 GHz The new product family from Rohde & Schwarz Professional test equipment for laboratory, service and production The R&S FS300 is a highly accurate spectrum analyzer

More information

GC723A / GC724B Cable and Antenna Analyzer

GC723A / GC724B Cable and Antenna Analyzer www.gctm.net GC723A / GC724B Cable and Antenna Analyzer GC723A / GC724B Cable and Antenna Analyzer Introduction A large number of abnormal cell site problems are typically caused by the antenna system,

More information

Insulating oil testing

Insulating oil testing Insulating oil testing Insulating liquids are an important component of many electrical devices. Highly refined mineral oils, silicone oils, vegetable oils (natural ester) and synthetic ester ensure smooth

More information

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators. Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 3000A Features ppm linearity 0 ppm offset Current

More information

Quadrupole Power Supply Unit QPS400-3

Quadrupole Power Supply Unit QPS400-3 http://www.cgc-instruments.de/ Quadrupole Power Supply Unit QPS400-3 Instruction Manual Document version 1.00, created on 12.07.2004 Technical Data Quadrupole Power Supply Unit 3 400 V QPS400-3 Version

More information

N. TEST TEST DESCRIPTION

N. TEST TEST DESCRIPTION Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities

More information

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 1000A Features Linearity error maximum 1 ppm Fluxgate,

More information

Cable fault location in power cables. Systematics for cable testing, diagnosis and cable fault location

Cable fault location in power cables. Systematics for cable testing, diagnosis and cable fault location Cable fault location in power cables Systematics for cable testing, diagnosis and cable fault location CABLE JOINTS, CABLE TERMINATIONS, CABLE GLANDS, CABLE CLEATS FEEDER PILLARS, FUSE LINKS, ARC FLASH,

More information

Surge Generator for MIL-STD 1275

Surge Generator for MIL-STD 1275 Surge Generator for MIL-STD 1275 This generator PG1275 is specially designed for the test of the susceptibility to surges and spikes of military 28 Vdc electric circuits. The equipment allows performing

More information

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer.

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer. Spectrum Analyzers 2394A 1 khz to 13.2 GHz Spectrum Analyzer A spectrum analyzer with outstanding performance and a user friendly visual interface simplifying many complex measurements 1 khz to 13.2 GHz

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 700-SB ULTRASTAB I PM = 700 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features ± 10 V voltage output

More information

APS series of 4-quadrant amplifiers

APS series of 4-quadrant amplifiers APS series of 4-quadrant amplifiers 4-QUADRANT VOLTAGE / CURRENT AMPLIFIER Fig. 1: 4-quadrant amplifier APS 1000 NEW: Constant current mode The adjustable and desired output current is automatically regulated

More information

Pre location: Impulse-Current-Method (ICE)

Pre location: Impulse-Current-Method (ICE) 1 ICE (Impulse current method three phased 2 1.1 Ionisation delay time 2 1.2 DIRECT MODE 2 1.3 Output impedance of the generator 2 Surge generator as impulse source 3 High voltage test set as impulse source

More information

Automotive Scope/GMM/OBD II Code Reader

Automotive Scope/GMM/OBD II Code Reader Finest 1006 Automotive Scope/GMM/OBD II Code Reader Automotive On-board diagnostic systems of thesedays have gone a long way toward helping you locate a problem. But those systems aren't perfect and they

More information

Model 3102D 0-2 kv H.V. Power Supply

Model 3102D 0-2 kv H.V. Power Supply Features Compact single width NIM package Regulated up to ±2000 V dc. 1 ma output Noise and ripple 3 mv peak to peak Overload and short circuit protected Overload, inhibit and polarity status indicators

More information

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 370A Features Linearity error maximum 2 ppm 100

More information

RIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.

RIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design. RIGOL Data Sheet DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A Product Overview DG3000 Series Function/Arbitrary Waveform Generators adopt DDS technology, which enables

More information

7051Plus / 5051Plus. Extended Specification

7051Plus / 5051Plus. Extended Specification 7051Plus / 5051Plus Extended Specification V1.1 Time Electronics, Botany Industrial Estate,Tonbridge, Kent, TN9 1RH England Tel: 44 (0)1732 355993 Fax: 44 (0) 1732 770312. E-mail: mail@timeelectronics.co.uk

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 700-S ULTRASTAB I PM = 700 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)

More information

INSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL Copyright 2008 by Bird Electronic Corporation Instruction Book P/N Rev.

INSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL Copyright 2008 by Bird Electronic Corporation Instruction Book P/N Rev. INSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL 5012 Copyright 2008 by Bird Electronic Corporation Instruction Book P/N 920-5012 Rev. C Description The Bird 5012 Wideband Power Sensor (WPS) is a Thruline

More information

Exposure Level Tester ELT-400

Exposure Level Tester ELT-400 Safety Evaluation within a Magnetic Field Environment Exposure Level Tester ELT-400 Direct Evaluation of Field Exposure Compared to Major Standards (IEEE C95.6) Automatic Exposure Evaluation for Various

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer ITN 1000-S ULTRASTAB I PM = 1000 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)

More information

DECLARATION OF CONFORMITY

DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY Manufacturer's Name: Transmille Ltd. Manufacturer's Address: Unit 4, Select Business Centre Lodge Road Staplehurst TN12 0QW. United Kingdom. Declares, that the product Product

More information

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis Ultra-stable, high precision (ppm class) fluxgate technology DM Series current transducer for non-intrusive, isolated DC and AC current measurement up to 1500A Features Ø45mm aperture enabling large isolated

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer IN 1000-S N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)

More information

TECHNICAL DATA SHEET. Safety and function tester GLP1-g. Standard model GLP1-g ELECTRICAL SPECIFICATION

TECHNICAL DATA SHEET. Safety and function tester GLP1-g. Standard model GLP1-g ELECTRICAL SPECIFICATION TECHNICAL DATA SHEET Safety and function tester GLP1-g Revision 2.7 / valid from July 2017 Standard model GLP1-g ELECTRICAL SPECIFICATION Supply voltage Mains frequency No load current consumption 110

More information

GA GHz. Digital Spectrum Analyzer

GA GHz. Digital Spectrum Analyzer Digital Spectrum Analyzer GA4063 3GHz Professional Performance Robust Measurement features High frequency stability Easy- to-use User Interface Compact size, Light weight, Portable design www.attenelectronics.com

More information

2801 Multilock. Communications System Analyzer. Data Sheet. Boosting wireless efficiency

2801 Multilock. Communications System Analyzer. Data Sheet. Boosting wireless efficiency Data Sheet 2801 Multilock Communications System Analyzer Boosting wireless efficiency A real multi-talented instrument the Willtek 2801 Multilock The Willtek 2801 Multilock is a test instrument for multiple

More information

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators. DL000ID Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 3000A Features ppm linearity 6 ppm offset

More information

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write 3 Dynatel 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write Designed to be more accurate, faster and more integrated than any other locator on the market,

More information

EMC / FIELD STRENGTH Test receivers. Fast and straightforward: diagnostic and precompliance measurements with the R&S ESRP

EMC / FIELD STRENGTH Test receivers. Fast and straightforward: diagnostic and precompliance measurements with the R&S ESRP EMC / FIELD STRENGTH Test receivers Fast and straightforward: diagnostic and precompliance measurements with the R&S ESRP 54 Many of the requirements such as speed, functionality and ease of use imposed

More information

UAT-600 Series. amprobe.com

UAT-600 Series. amprobe.com UAT-600 Series Underground Utilities Locator Accurately and safely pinpoint underground utilities before you dig Accidentally hitting a utility line during a project can lead to costly repairs and create

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) 1 MIG Tester Type MIG2000-6 Technical Specification E-MIG2000-6 revised: 07. May 2009 1 MIG Tester Type MIG2000-6 1

More information

portable affordable CDS Series Cable Fault Locators Thumpers - Surge Generators

portable affordable CDS Series Cable Fault Locators Thumpers - Surge Generators portable CDS Series Cable Fault Locators Thumpers - Surge Generators HVI offers the most complete fault locator packages available for primary cable. HVI offers the only VLF Thumper combination ideal for

More information

SVERKER 900 Relay and Substation Test System

SVERKER 900 Relay and Substation Test System SVERKER 900 The toolbox for substation 3-phase testing Three currents and four voltages Stand-alone functionality Rugged and reliable for field use Generation of 900 V and 105 A in single phase mode Secondary

More information

DS10000ULFS-10V/10kA

DS10000ULFS-10V/10kA Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 11kA Features Linearity error maximum +/- 7ppm

More information

Dodecahedron Speaker Set

Dodecahedron Speaker Set Dodecahedron Speaker Set Omnidirectional Sound Source Comprised of the DS3 Dodecahedron Loudspeaker and the PA3 Power Amplifier, the set generates a Pink noise signal with an acoustically-flat frequency

More information

Green LED (right of 'D' type connector)

Green LED (right of 'D' type connector) 3050A EXTENDED SPECIFICATIONS General Specifications TRANSMILLE LTD Warm Up Time Double the time since last used up to 20 minutes maximum Standard Interfaces USB Optional Interfaces GPIB (IEEE-488) : RS232

More information

UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28

UniStream 5 Technical Specifications US5-B5-RA28, US5-B10-RA28 UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28 Unitronics UniStream 5" are PLC+HMI All-in-One programmable controllers that comprise built-in HMI and built-in I/Os. The series is available

More information

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C S O L U T I O N S Y O U R S O U R C E F O R T O P Q U A L I T Y T E S T E Q U I P M E N T w w w. h v t e c h n o l o g i e s. c o m Company

More information

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 600A Features Linearity error maximum 1.5 ppm Fluxgate,

More information

GFT Channel Digital Delay Generator

GFT Channel Digital Delay Generator Features 20 independent delay Channels 100 ps resolution 25 ps rms jitter 10 second range Output pulse up to 6 V/50 Ω Independent trigger for every channel Four triggers Three are repetitive from three

More information

TileCal Analogue Cable Measurement Report

TileCal Analogue Cable Measurement Report Weiming Qian w.qian@rl.ac.uk +44-1235-446128 Rutherford Appleton Laboratory, UK 25 August 2005 Contents Contents... 2 1 Scope... 3 2 Impedance measurements... 3 2.1 Test setup... 3 2.2 Differential mode

More information

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 2000A Features 20 ppm linearity 15 ppm offset 10V

More information

Localizer provides signal generation over the Localizer band of to MHz with 90 Hz and 150 Hz tones, amplitude modulated

Localizer provides signal generation over the Localizer band of to MHz with 90 Hz and 150 Hz tones, amplitude modulated The IFR 4000 verifies the operation and installation of ILS, VOR and Marker Beacon receivers and VHF/UHF AM/FM and HF AM/SSB transceivers. The IFR 4000, with its lightweight size (under 8 lbs.), long run

More information