1 Electro-Hydraulic -Way Directional Servo Valve Model WS 2 E. and WSE 2 E. (Series X) Size (D 5)... 6 PSI (5 bar)... 2 GPM (75 L/min) R /6.98 R /6.98 Replaces: 5.9 Features: Servo valve for the closed loop control of position, force and velocity Two stage modular design for easy maintenance st stage is a flapper/nozzle design Mounts on standard ISO -5, NFP T.5. M R and NSI 9.7 D 5 interface, with additional X port for external piloting For subplates, see R 5 5 Can be used in conjunction with several feedback devices Dry torque motor which is isolated and cannot be contaminated by the fluid May also be used as a -way valve 5 different coils available to meet your requirements Valve electronics are available separately (standard plug-in Euro card design) or integrated into the valve Valve with integrated electronics are adjusted and tested as a unit K 22-5 K 26- Model WS 2 EM -X/... with mechanical feedback, associated electronic amplifier card (ordered separately) Model WSE 2 EE -X/... with electronic feedback and integrated electronics Table of contents Description Page Functional description 2 Sectional diagram Ordering code Explanation of ordering code 5 Valve symbols 5 Technical data general 6 Technical data hydraulic 6 Technical data electrical 7 Technical data inductive positional transducer 7 Electrical connections for external electronics 8 Electrical connections for integrated electronics 9 Description Page Operating curves flow vs. load Operating curves flow vs. signal Operating curves frequency response, barometric feedback Operating curves frequency response, mechanical feedback Operating curves frequency response, electrical feedback 2 Unit dimensions mechanical feedback Unit dimensions electrical feedback Unit dimensions barometric feedback Unit dimensions, sandwich plate for external pilot oil drain 5 Flushing plate, flushing instructions 5 External control electronics 6 Note: For service manual, request RDE S For complete parts list, request RDE E! /6

2 R /6.98 Functional description Valves Model WS 2 E... and WSE 2E... are electronically operated 2-stage servo valves. These valves are primarily used for closed loop control of position, force and velocity. These valves consist of two stages, the st stage (2), has a magnetic torque motor () and is of flapper/nozzle type design. The 2 nd stage (9) of the valve has a precision ground -way control spool and a feedback system which may be either mechanical, electrical or barometric as described below. Pilot control ( st stage) The st stage is a pilot valve which is electronically operated by a servo amplifier. The flapper/nozzle configuration functions like a Hydraulic mplifier. The armature of the torque motor () is tilted from the neutral position by an electrical current, thereby offsetting the flapper () between the two orifices (). This change in flapper position creates a change in the flow area, in relation to the two fixed orifices, which therefore causes a differential pressure. This controls the spool (9) in the second stage of the valve. The valve can be ordered in conjunction with a separate electronic amplifier card (Model WS), or it can also be ordered with the electronics integrated into the valve (Model WSE) depending on what is best for the application. Model WS, requires separate electronic amplifier To control this valve an external electronic control (servo amplifier) is used, which amplifies the input signal to a level required for the output signal to the valve. Depending on the specific application, several types of amplifiers are available. Model WSE, integrated electronics To control this valve, a specially tuned electronic control (6) is integrated in the valve, under the cover. This closed loop control, output stage and the oscillator/demodulator are molded into the cover. The command value can either be a regulated voltage (± V), or a regulated current (± m), causing the valve spool to move. Mechanical feedback on the 2nd stage (Fig.. and.2) The control spool in the second stage (9) is physically connected to the torque motor () with the mechanical feedback linkage (5). The torque tube () centers the armature (5) and the flapper () into the neutral centered position, when de-energized. When a current is supplied to the torque motor () a magnetic field is generated which changes the position tilts the T bar (5), and therefore also the flapper () and feedback spring (5). This movement of the flapper, closer to one and farther from the other fixed orifices (), causes a differential pressure which acts on the spool. Due to the effects of the pressure differential, the control spool (9), is shifted and continues to move until the pressure is again equalized on both sides. Therefore, the stroke of the control spool (9) within the sleeve () is directly proportional to input current from the electronic servo amplifier. Electrical feedback on the 2 nd stage (Fig. 2. and 2.2) The control spool in the second stage (9) is physically connected to a rod (7) which is able to move in the inductive positional transducer (6). Spool movement is continually monitored and any change is sensed instantaneously. Dependant on spool position, different value voltage signals are fedback to the associated electronic amplifier, for comparison of actual vs. desired position and error correction if required. When current is supplied to the torque motor () a magnetic field is generated which changes the position tilts the T bar (5) and therefore also the flapper (). This movement of the flapper, closer to one and farther from the other fixed orifices (), causes a differential pressure between the control chambers (8) & () which acts on the spool. Due to the effects of the pressure differential, the control spool (9) and feedback rod (7) are shifted and continue to move until the actual feedback value agrees with the desired input signal value. Then the pressure is again equalized on both sides and the control signal is at zero. Therefore, the stroke of the control spool (9) within the sleeve () is directly proportional to input current from the electronic servo amplifier. arometric feedback of the 2 nd stage (Fig. and.2) In the de-energized position the control spool in the second stage (9) is pressure balanced, and is held in the neutral or centered position by the contol springs (2). When current is supplied to the torque motor () a magnetic field is generated which changes the position tilts the T bar (5) and therefore also the flapper (). This movement of the flapper, closer to one and farther from the other fixed orifices (), causes a differential pressure between the control chambers (8) & () which acts on the spool. Due to the effects of the pressure differential, the control spool (9) is shifted and continues to move until control springs (2), flow forces and pressure is again in balance. Since the control springs have a linear characteristic, the stroke of the control spool (9) within the sleeve () is directly proportional to input current from the electronic servo amplifier. 2/6

3 Valve with separate electronic amplifier Valve with integrated electronics 6 R /6.98 P T Fig. Mechanical feedback (standard with external electronics) Fig.2 Mechanical feedback P T 9 8 Fig 2. Electrical feedback P T Fig 2.2 Electrical feedback (standard with integrated electronics) 6 P T Fig. arometrical feedback 9 8 Fig.2 arometrical feedback /6

4 R /6.98 Ordering code X Electrically operated 2-stage, -way servovalve: with separate electronics = WS 2 E with integrated electronics = WSE 2 E Mechanical feedback (standard for valves with separate electronic amplifier = M Electrical feedback (standard for valves with integrated electronics) = E arometric feedback (spring centered) = Size (NFP/NSI D 5) = Series to 9 = X ( to 9 externally interchangeable) Flow at a pressure drop across the valve of p V = PSI (7 bar).5 GPM (2 L/min) = 2. GPM (5 L/min) = GPM ( L/min) = 5. GPM (2 L/min) = 2 8 GPM ( L/min) = 2 GPM (5 L/min) = 5 6 GPM (6 L/min) = 6 2 GPM (75 L/min) = 75 (tolerance band for the flow vs. signal function is shown on page ) 2 Valves with separate electronics: Coil no. 5 m / 5 Ohm per coil = Coil no. 2 m / Ohm per coil (Standard) = 2 Coil no. 7.5 m / 2 Ohm per coil = Coil no. 2 m / 8 Ohm per coil = Coil no. 5 5 m / 28 Ohm per coil = 5 Valves with integrated electronics: input signal: command value ± m / kω NNNNNNNN = 8 command value ± V / 5 kω (standard) N = 9 Pilot supply and Valve Model: WS 2 EM WS 2 EE drain WSE 2 EM WS 2 E WSE 2 EE WSE 2 E Externally piloted, externally drained = Internally piloted, externally drained = E Externally piloted, internally drained = T Internally piloted, internally drained (standard) = ET available; = not available Remarks: Sandwich plate (X X), must be ordered separately, see page 6 item 9 Test unit for WSE (integrated electronics) Model number VT-VET-, Series X, data sheet R The test unit is used for the control and function monitoring of integrated electronic valves. * 5 Further details in clear text M = NR seals suitable for petroleum oils (HM, HL, HLP) V = FPM seals suitable for phosphate ester fluids (HFD-R) Spool overlap =.5 to.5 % positive =.5 to.5 % negative C =. to 5. % positive D = to.5 % positive E = to.5 % negative Electrical connections Valves with separate electronics: K8 = socket to size S 2 S without mating plug without electric socket mating connectors RR 2 6 (order separately) Valves with integrated electronics: electrical feedback: K9 = socket to size E S 6 S without mating plug mating connectors RR 59 (order separately) mechanical or barometric feedback: K = socket to size E S 5 S without mating plug mating connectors RR 92 (order separately) Input pressure range to the first stage 5 = feedback mechanical 5 6 PSI ( 5 bar) = { 5 58 PSI ( bar) 7 = electric or 58 PSI ( 7 bar) = barometrical 2 PSI (7 bar) 2 = feedback 2 5 PSI ( 2 bar) 5 = 5 6 PSI (2 5 bar) Test unit for WS2 (battery driven) Part number for ordering RR 57, see data sheet R Note: Test unit only for valves with separate electronics. only for coil numbers, 2 and. with electrical feedback only the maximum flow will be signaled. /6

5 Explanation of ordering code Nominal flow The nominal flow is the flow in GPM (L/min) at nominal current signal and at PSI (7 bar) pressure drop [5 PSI (5 bar) per control land]. Other values will necessarily produce a different flow rate. The flow tolerance band and also the influences of saturation of flows equal to or above 6. GPM (6 L/min) must be noted (see page ). If required, servo valves can be supplied with special operating curves (with a subdued form, progressive, or with special spool overlaps). ny special characteristics or parameters must be very clearly specified. 2 Coil electrical control data The control signal must be generated from a current regulated output stage. The standard coil for valves with separate electronics is spool number 2 ( m/ Ω). With coil numbers,, and 5, the closed loop electronic control (servo amplifier) must be custom matched with the valve. With integrated electronic controls, the signal value can be supplied as a voltage signal code 9, or for long distances [more than 82 ft (25 m) between the computer and the valve] as a current signal code 8. Input pressure range to the st stage The pilot pressure should be as constant as possible. Therefore, it is often best to externally pilot the valve via port X. Mechanical feedback Pilot pressure: 5 to 6 PSI ( to 5 bar) The pilot pressure should not be less than 6% of the system pressure order to avoid reduction in the controllability, due to flow forces on the valves control spool. Electric feedback The pilot pressure should be kept within the pressure range where possible. In order to influence the dynamic response of the valve, it may be fed with a higher or lower pilot pressure. When the input pressure of 58 PSI ( bar), it is always better to keep pilot pressure at port X equal to the system pressure at port P. R /6.98 arometric feedback system The pilot pressure can not be higher than the maximum pressure in the model code designation. The nominal flow refers to the mean pressure of the relevant pressure stage and changes with the pressure level. Spool overlap The spool overlap given in % refers to the control spool stroke of.5 inches (.8 mm). For closed loop control, we recommend an overlap close to zero or slightly negative, like the E spool overlap. Spool overlap This is the limit of the range for applications inclosed and open loop controls. The position flow is much less than for D. Spool overlap Mostly applied at pressures less than 22 PSI ( bar). Suitable for position, force and pressure control in closed loop, it requires a higher degree of damping than with spool D, and a greater position flow is only of secondary importance. Spool overlap C Suitable for open loop or velocity control. Spool overlap D Suitable as a universal overlap for closed loop control of position, force and velocity with low position flow, however with lower damping than that of spool. Spool overlap E Suitable for highly accurate applications with a somewhat higher position flow than with spool D. Main applications: control of pressure and force in a closed loop. 5 Further details to be written in clear text Special requirements should be specified here in clear text. fter the receipt of an order, this will be checked by the factory and the valve code extended by an additional code when required. Symbols (simplified) Servo valve for separate electronics Servo valve with integrated electronics a, b a, b P T P T Mechanical feedback M Electrical feedback E arometric feedback a P T b a, b a P T b a, b a P T b a, b 5/6

6 R /6.98 Technical data (For applications outside these parameters please consult us!) General Weight (approx.) lbs (kg) WS 2 EM -X/ (.) WS 2 EE -X/..with separate electronics.9 (.9) WS 2 E -X/...5 (.6) WSE 2 EM -X/ (.2) WSE 2 EE -X/..with integrated electronics. (2.) WSE 2 E -X/...75 (.7) dditional items: Sandwich plate for external piloting (model " ", "T"), see page 5, item 6.66 (.) Sandwich plate for external drain (model " ", "E"), see page 5.55 (.25) Flushing plate, see page (.) Cable connections 6-/2 ft (2 m) long (for valves with separate electronics only) each cable. (.2) Mounting position Optional, however, the pilot pressure must be 5 PSI ( bar) before start-up mbient temperature range F ( C) 22 to +58 ( to +7) with external electronics 22 to + ( to +6) for WSE 2 E. (with integrated electronics) Hydraulic, measured at ν = 9 SUS (2 mm 2 /s) and t = F ( C) Feedback system Mechanical Electrical (V p = 5) ) arometric Operating pressure range PSI (bar) 5 to 6 ( to 5) 5 to 6 ( to 5) 5 to 6 ( to 5) ports,, P, X (note pressure range) (note pressure range) Return line pressure PSI (bar) Pressure peaks <5 () Pressure peaks <5 () Pressure peaks <5 () ports T, Y static <5 () static <5 () static <5 () (Return line pressure reduces spool stroke) Hydraulic fluid Petroleum oil (HM, HL, HLP) Phosphate ester fluids (HFD-R) Fluid cleanliness Maximum allowable fluid cleanliness level Class 6/, according to ISO 6. Therefore, we recommend a filter with a minimum retention rate of ß 5 without bypass valve, with clogging indicator directly before the valve or as close as possible. Fluid temperature range F ( C) 5 to +76 ( to +8) Viscosity range SUS (mm 2 /s) 92 to 76 (2 to 8); preferably to 28 ( to 5) Nominal flow (Q N ) GPM (L/min) ±% at p V = PSI (7 bar) 2) (2) (5) () (2) () (5) (6) (75) Flow in center pos. 5) GPM (L/min).2 GPM p v.2 GPM (.8 L/min) control fluid for pilot stage (.8 L/min) 5 PSI (7 bar) Pilot leakage & leakage p v.2 GPM (.8 L/min).2 GPM p +. Q of whole valve ), ) 5 PSI (7 bar) +. Q N N ) (.8 L/min) 5 PSI (7 bar) The centered position flow data is valid only without an overriding dither signal; it will increase if dither is applied. Hysteresis % (pressure stage and 7) (with dither optimized) (pressure stages, 2, 5) Reversal voltage %... Sensitivity % Pressure gain Spool overlap: 5% of p for % spool stroke (from the hydraulic null point) ) V p = electrical gain Spool overlap:, E Spool overlap: D 2) p V = pressure drop across valve in PSI (bar) ) Q N = Nominal flow in GPM (L/min) % of p for % spool stroke (from the hydraulic null point) 75% of p for % spool stroke (from the hydraulic null point) ) p = Operating pressure in PSI (bar) 5) The zero flow data is valid without overlapping dither signal and increase with the dither part. 6/6

7 Technical Data (For applications outside these parameters please consult us!) R /6.98 Electrical Feedback type mechanical electrical (Vp = 5) barometric Null compensation current % < 5, long term < 8 <, longterm < 5 Null offset, starting with a nullpoint corrected valve with alteration of: Fluid temperature % < 2 / 68 F (2 C) < / 68 F (2 C) mbient temperature % < 2 / 68 F (2 C) < / 68 F (2 C) System pressure (.8 to.2) x p in bar % < 2 < < Return line pressure ( to.) x p in bar % < 2 < < Insulation Exceeds NEM class special installation on request Type of signal analog Coil number ssociated amplifier ** * ** ** ** integrated electronics (The amplifier card must *With mechanical and barometric feedback use amplifier be ordered separately) Model SR 2, see R 29 98, or amplifier Model VT 6, see R For electrical feedback use amplifier Model SR, see R , or amplifier Model VT 6, see R **Please consult us for electronics. Nominal current per coil m Resistance per coil Ω Inductivity at 6 Hz and% nominal current Series circuit H Parallel circuit H Recommended The amplitude of the dither depends on the hydraulic dither signal: f = Hz installation; maximum limit % of nominal current Command value current regulated m ± voltage regulated V ± Input resistance kω 5 Supply voltage (± %) V ±5 ct. position value for spool setting V approx. ± at % command value (only Model WSE2EE...) Electrical (inductive positional transducer) for external electronics Electrical measuring system Differential transformer Nominal spool stroke inches (mm) ±. (.8) Sensitivity with.5 khz mv/v.7 () carrier frequency in (mm) Resolution (static) continuous Feed voltage (V eff ) V.5 Carrier frequency khz.5 7/6

8 R /6.98 Plug-in connectors For model WS2 (external electronics) Plug-in connector must be ordered separately under part no. RR 2 6; For PIN allocation see below and block circuit diagram on page 2.6 (6).79 /F (2) Ø. (28) For model WSE2EM and WSE2E (integrated electronics) and model WS2EE (external electronics, inductive feedback) Plug-in connector must be ordered separately part no. RR 92; For PIN allocation see below.9 () For model WSE2EE (integrated electronics) part no. RR 59; For PIN allocation see below Electrical connections: Model WS 2 E... (valves for external electronics) Pilot control (st stage) Plug pin connections Positional transducer Plug pin connections blue green green/yellow blue C D red yellow C E D red black brown Electrical connections to the servo valve can be made either in parallel, or in series. For safety, due to the lower inductivity obtained, we recommend parallel connection. Parallel connection: For plug connection, connect to and C to D. For cable connection, connect yellow to brown, and green to white. Series connection: For plug connection, connect to C. For cable connection, connect brown to green. n electrical input of (+) to D ( ) for plug connection, or yellow lead (+) to white lead ( ) for cable connection, provides a flow direction in the 2nd stage of P to and to T. Reversing the direction of the current reverses flow direction in the 2nd stage, to P to and to T. Warning: Connection at the plug, or the white wire in the cable must not be connected (due to radio interference effects). 8/6

9 Electrical connections and technical data: Model WSE 2E.... (Valves with integrated electronics) Models WSE 2 EM.. and WSE 2 E.. (mechanical and barometric feedback) R /6.98 Terminal connection Coil "8" Coil "9" R e Integrated electronics C D E Supply + 5 V + 5 V voltage in V 5 V 5 V (± %) C V V Command value D ± m ± V E R e = kω R e 5 kω Current maximum maximum required at m m plug D connection ± m.2 m E Command value: Command value at plug connection D, negative polarity with respect to plug connection E gives a flow from P to and to T. Command value at plug connection D, positive polarity with respect to plug connection E gives a flow from P to and to T. Model WSE 2 EE.. (electrical feedback) R e C D E F Terminal connection Coil "8" Coil "9" Supply + 5 V + 5 V voltage in V 5 V 5 V (± %) C V V Command value D ± m ± V E R e = kω R e 5 kω Measured output F Nominal stroke corresponds to ± V for control spool against V; R i.7 kω Integrated electronics Current maximum maximum required at 2 m 2 m plug D connection ± m.2 m E Command value: Command value at plug connection D, negative polarity with respect to plug connection E gives a flow from P to and to T. Measured output F has a negative polarity with respect to earth ground V. Command value at plug connection D, positive polarity with respect to plug connection E gives a flow from P to and to T. Measured output F has a positive signal with regard to earth ground V. 9/6

10 R /6.98 Operating curves: measured at ν = 9 SUS ( mm 2 /s) and t = 22 F (5 o C) Flow vs. load function for all feedback systems (Tolerance band ±%) Note: Flows are calculated values Nominal flow Q N in L/min p.8 Q = Q N. v 5 PSI (7 bar) Valve pressure drop p v in bar p V = Valve pressure drop (input pressure minus return line pressure minus load induced pressure) Tolerance zone for the flow-signal function Zero through break according to spool overlap 8 6 Flow in % Typical flow curve P ; T Tolerance field Command value in % 6 8 P ; T 5 With flows of 6 GPM (6 L/min), the effects of flow saturation must be observed. 5 Frequency response curves: measured at ν = 9 SUS ( mm 2 /s) and t = 22 F (5 o C) Model WS 2 E.. and WSE 2 E.. arometric feedback mplitude ratio in d Nominal flow Q N 8. GPM ( L/min) Frequency in Hz Phase lag in degrees mplitude ratio in d Nominal flow Q N 2 GPM (5 L/min) Frequency in Hz Phase lag in degrees Pressure stage: = 58 PSI = PSI = 2 PSI = 5 PSI = 6 PSI ( bar) (7 bar) ( bar) (2 bar) (5 bar) /6

11 Operating curves, measured at ν = 9 SUS ( mm 2 /s) and t = 22 F (5 o C) Model WS 2 EM.. and WSE 2 EM.. Mechanical feedback Nominal flow Q N 8 GPM ( L/min) Crossover functions Stroke in % Nominal flow Q N 2 GPM (5 L/min) Crossover functions Stroke in % R / Time in ms Time in ms Pressure stage: = 58 PSI = PSI = 2 PSI = 5 PSI = 6 PSI ( bar) (7 bar) ( bar) (2 bar) (5 bar) Frequency response curves, operating pressure 2 PSI ( bar) Frequency response curves, operating pressure 2 PSI ( bar) mplitude ratio in d Phase lag in degrees mplitude ratio in d Phase lag in degrees Frequency in Hz Frequency in Hz Signal: = ± 5% = ± 25% = ± % ssociated dependency of frequency on operating pressure ssociated dependency of frequency on operating pressure Frequency in Hz Frequency in Hz (5) () (5) (2) (25) (2) Operating pressure in PSI (bar) (5) () (5) (2) (25) (2) Operating pressure in PSI (bar) Signal: = ± 5% = ± 25% = ± % /6

12 R /6.98 Operating curves: measured at ν = 9 SUS ( mm 2 /s) and t = 22 F (5 o C) Model WS 2 EE.. and WSE 2 EE.. Electrical feedback system Nominal flow Q N 8 GPM ( L/min), electrical gain (amplification) Vp = 5 Crossover functions Stoke in % Time in ms Frequency response curves, operating pressure 2 PSI ( bar), Vp = 5 Nominal flow Q N 2 GPM (5 L/min, electrical gain (amplification) Vp = 5 Crossover functions Stoke in % Time in ms Operating pressure = 58, 5, 2 PSI (, 7, bar) = 6 PSI (2 bar) = 57 PSI (5 bar) Frequency response curves, operating pressure 2 PSI ( bar), Vp = 5 mplitude ratio in d Phase lad in degrees Frequency in Hz Frequency in Hz Signal: = ± 5% = ± 25% = ± % ssociated dependency of frequency on operating pressure 2 mplitude ratio in d ssociated dependency of frequency on operating pressure Phase lad in degrees 9 Frequency in Hz Frequency in Hz () () (7) () (2) (5) () () (7) () (2) (5) Operating pressure in PSI (bar) Operating pressure in PSI (bar) Signal: = ± 5% = ± 25% = ± % 2/6

13 Unit dimensions: dimensions in inches (millimeters) R /6.98 Mechanical feedback / with separate electronics Model WS 2 EM -X/ (standard) Zero point adjustment remove plug (2.5 mm /F) to access the potentiometer to set the zero point 2. Plug type MS 6 E S-2 S to non-integrated valve Ordering code: RR Plug type MS 6 E S-5 S to integrated valve Ordering code: RR 92 Space required to remove plug djustment on both sides for setting the Null point (centered position) of the valve (allen wrench mm /F) 5 Interchangeable filter element ( mm /F ) part no. RR 6 82 (for NR seals) part no. RR 6 8 (for FPM seals) 6 Valve mounting bolts, not included ) socket head cap screws /-2 UNC x 2" (M6 x 5) tightening torque = 7.67 lb-ft (. Nm) 7 Nameplate 8 Top cover can be rotated 8 9 Pilot stage (st stage) Second stage O-ring (2 x 2 mm); Ports,, P, T 2 O-ring (7 x.5 mm); Port X Optional port X for external pilot oil supply ore Ø.8 to.97 inches ( mm to 5 mm) If port X is to be used, the sandwich plate must be used. (This plate must be ordered separately) Warning! Port X is connected to pressure. If port X instead of X is to be used a sandwich plate (order separately, see page 5) Cover with integrated electronics.8 (6).6 (5).89 (8).28 (2.5).96 (2).8 (2.) (6.).276 (7). () 2.26 (5) 2 (5.8).69 (7.).6 (27).657 (6.7).72 (2).26 (.2).8 (2) (76).5 ().6 () T 2 X 6.2 (6) (68) X Mechanical feedback / integrated electronics Model WSE 2 EM -X/.6 (5) 6.69 (7) 2.95 (75) P T Ø.9 (9.8);. (.) Ø.26 (6.6) (26) 2.2 (57).575 () Ø.62 (5.7);.59 (.5) ; (.5) 2.62 (6). (2.5).82 (97)./. in./ mm 2 (R max ) Required surface finish of interface when mounting the valve without our subplate /F = cross flats Valve Mounting interface to ISO -5, NFP T.5. M R and NSI 9.7 D 5 except for port X. Subplates (8). () 2.8 (72). (2) G 66/2 (SE-6; 9/6-8) G 67/2 (SE-8; /-6) G 5/2 (SE-2; -/6-2) G 55/2 (SE-2; -/6-2) G 56/2 (SE-6; -5/6-2) with port X Subplates and valve mounting bolts must be ordered separately, see R 5 5 /6

14 R /6.98 Unit dimensions: dimensions in inches (millimeters) Electrical feedback / external electronic control Model WS 2 EE -X/ max. 2.6 (65).2 (26).26 (2) Electrical feedback / integral electronics Model WSE 2 EE -X/.26 (2).2 (26) (5) (52) 2.9 (5).95 (2).95 (2) 2.76 (7) 2. Plug compatible with Type MS 6 E S 2 S to non-integrated valve RR Plug compatible with Type MS 6 E S 5 S to non-integrated valve feedback RR Plug compatible with Type MS 6 E S 6 S to integrated electronics RR 59 Space required to remove plug (take care with the connecting cable) Setting for hydraulic zero point (allen key /F ) 5 Lock nut /F arometric feedback / external electronic control Model WS 2 E -X/ arometric feedback / integral electronics Model WSE 2 E -X/ 5.2 (26) 5.2 (26) (2).95 (2) 2.2 max..69 ().26 (2) max..69 ().26 (2) 2. Plug compatible with Type MS 6 E S 2 S to non-integrated valve RR Plug compatible with Type MS 6 E S 5 S to integrated electronics RR 92 Setting for hydraulic zero point (allen key /F ) 5 Lock nut /F /6

15 R /6.98 Unit dimensions, Sandwich plates for external pilot oil feed: dimensions in inches (millimeters) External pilot oil supply (models and T ) The servo valve always has port X. If there is no X port on the mounting surface, the sandwich plate (6) must be used with external pilot oil feed is required. Either port X or X2 may be used. 6 Sandwich plate with NR-seals, ordering code RR 9 82 FPM-seals, ordering code RR Valve mounting bolts ) socket head cap screws /-2 UNC x " (M6 x 75) tightening torque = 7.67 lb-ft (. Nm) 8 Mounting surface for the sandwich plate (6) 9 /" SP plug, ordering code RR 97 O-ring mm x 2 mm 2 O-ring (2 x 2 mm); ports,, P, T 2 O-ring (.82 x.78 mm); port X 2.6 (6).6 (5.5).98 (25).7 (.).276 (7).787 (2) 9 G /" (SP);.7 (2) deep.92 (2.5) X2 X2 X T P. (7.9).5 (85) X T /. in./ mm (R max ) Required surface finish of interface when mounting the valve without our subplate.2 (5) X External pilot oil drain (models and E ) Sandwich plate (22) is not be used with mechanical feedback or electrical feedback with integrated electronics. 22 Sandwich plate included 2 For pilot oil feed Model " ", port X may be used instead of port X for the oil feed. 22 Y only in valve type: WS 2 EE... WS 2 E... WS E 2 E... G /" (SP;.7 (2) deep 2 G /" (SP;.7 (2) deep X 2.2 (56) Y.6 (27) Unit dimensions, Flushing plate: dimensions in inches (millimeters) Symbol T P X T with NR-seals Ordering code RR O-ring (2 x 2 mm); ports,, P, T 2 O-ring (7 x.5 mm); port X 2 ) socket head cap screws /-2 UNC x 2" (M6 x 5) tightening torque =. lb-ft (5.5 Nm) In order to guarantee the perfect functioning of servo valves, the installation must be flushed prior to start-up. s a guide to the flushing time required, the following formula can be used: t = Flushing time in minutes V t 5 V = Tank contents in gallons (liters) Q q V = Pump flow in GPM (L/min) When refilling more than % of the tank contents, the flushing process should be repeated. Note: directional control valve with mounting pattern according to ISO -5, NFP/NSI D 5 is better than a flushing plate. Such a valve allows the actuator ports and lines to also be flushed. Refer to R (7).8 (6).7 (2) (9.7).969 (2.6).5 (.5) Ø.276 (7).8 (6).9 ().58 ().5 (9).7 (8) 2.26 (5) 2 (5.8).69 (7..6 (27).657 (6.7).26 (.2) T X P.7 (2) 9 T.79 (2) 5/6

16 R /6.98 Control electronics for valve type WS2EM and WS2E : servo amplifier SR 2 (must be ordered separately) external servo amplifier is used to control the valve. This changes the analogue input signal (command value) in such a way that a regulated current control of the servo valve can be effected using the output signal. Technical data Supply voltage V : ± 22 to 28 V smoothed Max. output current I max : ± 6 m Card dimensions: Eurocard x 6 mm, DIN 9 Front plate dimensions Height: U (28. mm) Width conductor side: HP (5.8 mm) Width component side: 7 HP For applications outside these parameters, please consult us! Detailed information: Data sheet R Terminal connections / block diagram Input Input 2 Input Signal voltage for relays K, K2, K Controller changeover +UL (L) Nominal value ctual value Controller output Supply voltage ± 22 to ±28 V = +2 V V 2 V 28a a 2a 6a a 2a 6c c 28c 2c c 6c 2c J Cu J9 2 Cu J6 L +VL 5 +VL L VL V7 V6 PD V K PID C6 C5 H Servo valve current I V = ( VL) (L) I J2 J C C K2 H2 V V H K V28 V a 26c 2a 2c 6a 6a c 8c a 8a 2c 8c 22c +5 V M 5 V D C Enable Reserve Contact loading V = 2 V / I =,5 P T +VL (L) +VL (L) Relays K and K as well as the PID controller are special models and are identified by a VT number when ordering. Positive command value at port c gives a flow at the servo valve from P to. Positive command value at port 2a gives a flow at the servo valve from P to. Ordering code VT-SR 2 S X 2-pin blade connector to DIN 62 form D = S (for installation in Euro-card racks and card holders) Series to 9 = X ( to 9: unchanged technical data and connection allocations) * Further details in clear text = without ± 5 V voltage regulator = with ± 5 V voltage regulator 6/6 Mannesmann Rexroth Corporation Rexroth Hydraulics Div., Industrial, 25 City Line Road, ethlehem, P 87-2 Tel. (6) 69-8 Fax: (6) Rexroth Hydraulics Div., Mobile, 7 Old Mansfield Road, Wooster, OH 69-9 Tel. () 26- Fax: () 26- ll rights reserved Subject to revision Printed in U.S..

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013 4-Way Servo Valve Model 4 WS. 2 E. 16..., (Series 2X) with Mounting attern to DIN 24 3 or CETO R 11 H Size 16... 40 SI (31 bar)... 3 GM (0 L/min) R 29 91/06.98 R 29 91/06.98 Replaces: 0.94 2 stage servo

More information

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y RA 9 /6.98 -Way Proportional Logic Cartridge Valve Model FE.. (Series X and X) Size 6... 6... 6 PSI (5 bar)... 75 GPM (8 L/min) RA 9 /6.98 Replaces: 5.9 Characteristics: Single land throttle valve (main

More information

4/3-way fast response valve Type 4WRGE

4/3-way fast response valve Type 4WRGE RE 9 7/.3 Replaces:.98 4/3-way fast response valve ype 4WRGE Nom. size max. operating pressure 35 ar Nom. sizes 6, 5 max. operating pressure 35 ar Series X Maximum flow 87 L/min H/ 568/95 ype 4WRGE L-X/35G4..K3...

More information

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback RA 29 939/06.98 Electronic Amplifier Model T 301 and T 3018 (Series 3X) for the control of proportional directional valves, without positional feedback RA 29 939/06.98 Replaces: 09.94 Electronic amplifier

More information

Proportional directional valves

Proportional directional valves 01/10 Proportional directional valves 6.12 Type 4WRPEH6...L2X NG 6 Up to 315 bar Up to 40L /min Contents Function and configuration 02 Ordering code 03 Symbols 03 Technical data 04 Electrical connection

More information

RA / /6. Replaces: Table of contents RA /06.98

RA / /6. Replaces: Table of contents RA /06.98 Electronic amplifier for the control of proportional directional ales with electrical position feedback Models VT 5024 and VT 5025, Series 1X RA 29 958/06.98 Replaces: 11.97 The amplifiers VT 5024 and

More information

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X RA 29 934/0.98 Electronic amplifier for the control of proportional valves without position control Model T 3024, Series 3X RA 29 934/2.9 The amplifier T 3024-3X is suitable for the control of pilot operated

More information

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Type 4WRPEH RE 29035 Edition: 2017-04 Replaces: 2015-02 Size 6 Component series 2X Maximum

More information

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X Electronic amplifier for the control of proportional valves without position control Model T 3006, Series 3X RA 29 926/06.98 Replaces: 02.96 The amplifier T 3006-3X is suitable for the control of pilot

More information

DENISON HYDRAULICS Proportional Pressure Control Valves

DENISON HYDRAULICS Proportional Pressure Control Valves DENISON HYDRAULICS Proportional Pressure Control Valves Series 4VP01 Cetop 03 Publ. 3-EN 2200-B, replaces 3-EN 2200-A FEATURES, SYMBOLS x FEATURES Direct operated pressure relief valve for flow up-to max.

More information

Proportional Directional Control Valves Nominal sizes 16 and 25

Proportional Directional Control Valves Nominal sizes 16 and 25 Proportional Directional Control Valves Nominal sizes 16 and 25 Pilot operated, electrically adjustable Interface acc. to DIN 24 340 and ISO 4401 PN [p max. ] = 315 bar 7502968.06.01.06 Description Design

More information

4/3 proportional directional valve direct operated, with integrated electronics

4/3 proportional directional valve direct operated, with integrated electronics 4/ proptional directional valve direct operated, with integrated electronics RE 2964/. Replaces: 2.2 /6 Type 4WREEM Sizes 6 and Component series 2X Maximum operating pressure 5 bar Maximum flow: 9 l/min

More information

MDSD (Series 2X) Mobile Dual Solenoid Driver

MDSD (Series 2X) Mobile Dual Solenoid Driver R 64/. MDSD (Series X) Mobile Dual Solenoid Driver R 64/.5 Replaces: 6.4 The MDSD amplifier provides control of components that use proportional solenoids without LVDTs for actuation. The MDSD orporates

More information

Proportional Directional Control Valves Series D*FH and D*FM General Description Operation Features Series D*FH Series D*FM

Proportional Directional Control Valves Series D*FH and D*FM General Description Operation Features Series D*FH Series D*FM Catalog HY14-255/ echnical Information General Description eries D*FH is a high response, proportional servovalve with an on-board drive amplifier. he D*FM is a high response, direct actuated servovalve

More information

4/3 Proportional Directional Valve, Size SAE 10

4/3 Proportional Directional Valve, Size SAE 10 / Proportional Directional Valve, Size SAE Q max =. gpm [ l/min], p max = psi [ bar] Direct acting, sliding-spool design, with solenoid operation Series PDFC- Description Series PDFC proportional directional

More information

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6 Analogue amplifier RE 29980/09.05 Replaces: 02.03 1/6 Type VT-SR2 Series 1X H5658 Table of contents Contents Page eatures 1 Ordering code 2 unctional description 2 Technical data 3 Block circuit diagram

More information

4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features.

4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features. 4/ proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF RE 9048 Edition: 0-0 Replaces:. Sizes 6 and 0 Component series X Maximum operating pressure

More information

Servo-Performance Proportional Directional Valves with Feedback. K(B)SDG4V-3 1* Series Pressures to 350 bar (5075 psi)

Servo-Performance Proportional Directional Valves with Feedback. K(B)SDG4V-3 1* Series Pressures to 350 bar (5075 psi) Servo-Performance Proportional Directional Valves with Feedback K(B)SDG4V-3 1* Series Pressures to 350 bar (5075 psi) Contents INTRODUCTION General description.... 03 Features and benefits.... 03 Typical

More information

Valve amplifier for proportional pressure valves

Valve amplifier for proportional pressure valves Valve amplifier for proportional pressure valves Type VT-MRMA1-1 RE 30214 Edition: 2017-03 Replaces: 04.13 Component series 1X Analog, modular design Suitable for controlling a direct current motor-operated

More information

Proportional Directional Control Valves Size 6

Proportional Directional Control Valves Size 6 Proportional Directional Control Valves Size 6 Direct controlled, electrically adjustable Interface to DIN 2 30 and ISO 0 PN [p max. ] = 35 bar 750055.06.02.06 Description (standard units) Design The proportional

More information

DIN (NFPA/ISO/CETOP) NG6 (3) NG10

DIN (NFPA/ISO/CETOP) NG6 (3) NG10 13169 : Mutter R.S R.S Mutter : 13169 Calog HY14-255/US Technical Informion General direct opered proportional directional control solenoid valves are available with or without integred control electronics.

More information

Valve amplifier for proportional valves with electrical position feedback

Valve amplifier for proportional valves with electrical position feedback Valve amplifier for proportional valves with electrical position feedback Type VT-MRPA1-... RE 30221 Edition: 2015-02 Replaces: 2013-08 Component series 1X Analog, modular design Intended for controlling

More information

Accessories Power Amplifiers

Accessories Power Amplifiers Front Panel Vickers Models with Command Logic Module and Ramps EEA-PAM-5**-B- Series General Description Features and Benefits The EEA-PAM-5**-B- Eurocards are power amplifiers with a four-input (demand

More information

Direct Operated Proportional DC Valve Series D1FP

Direct Operated Proportional DC Valve Series D1FP Catalogue HY11-500/UK Characteristics The direct operated control valve D1FP of the nominal size NG0 (CETOP 0) shows extremly high dynamics combined with maximum flow. It is the preferred choice for highest

More information

Electro-hydraulic Servo Valve Systems

Electro-hydraulic Servo Valve Systems Fluidsys Training Centre, Bangalore offers an extensive range of skill-based and industry-relevant courses in the field of Pneumatics and Hydraulics. For more details, please visit the website: https://fluidsys.org

More information

Proportional Directional Control Valves Size 6

Proportional Directional Control Valves Size 6 Proportional Directional Control Valves Size 6 Direct operated, positioncontrolled Interface to DIN 2 30 and ISO 0 PN [p max. ] = 35 bar 75079.06.03.06 Description (standard units) Design The proportional

More information

RT-5005/5006/5007/5008

RT-5005/5006/5007/5008 Replaces: 09.12 Electro-hydraulic Control Digital Proportional Amplifier Type: RT-5005/5006/5007/5008 Series: 3X Table of contents Contents Page Features 1 Ordering code 2 Functional description 2 Block

More information

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05 Valve amplifier for proportional directional valves Type VT-VRPA RE 0119 Edition: 01-0 Replaces: 07.05 Component series 1X Analog, Euro-card format Suitable for controlling / proportional directional valves

More information

PROPORTIONAL PRESSURE CONTROLS TECNORD

PROPORTIONAL PRESSURE CONTROLS TECNORD Proportional Pressure Relief Valves Normally closed GPM PSI LPM BAR MODEL PAGE 0,8 430 3 30 EB-PRL 18 12 3000 45 207 EE-PRB 20 30 3000 114 207 ET-PRB 22 Normally open GPM PSI LPM BAR MODEL PAGE 12 3000

More information

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X Analog amplifier RE 29926/10.06 Replaces: 0.03 /8 Type VT 3006 Component Series 3X H4240_d Table of contents Contents Page eatures 1 Ordering code 2 unctional Description 2 and 3 Block circuit / pin allocation

More information

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces: Replaces: 09.12 Electro-hydraulic Control Digital Proportional Amplifier Type: RT-VSPA2-50 Series: 3X Table of contents Contents Page Features 1 Ordering code 2 Functional description 2 Block circuit diagram

More information

Single Ended Linear DC Servo Amplifier

Single Ended Linear DC Servo Amplifier Service Data Vickers Servo Valves Single Ended Linear DC Servo Amplifier EM-A-0 Revised 09/0/ I-0-S General This manual is written primarily to establish a logical troubleshooting procedure for the solid

More information

SERVO VALVES. Maximum Flow. Maximum Operating Pressure MPa (PSI) U.S.GPM Page. Graphic Symbols.

SERVO VALVES. Maximum Flow. Maximum Operating Pressure MPa (PSI) U.S.GPM Page. Graphic Symbols. I SERVO VALVES Valve Graphic Symbols Maximum Operating Pressure MPa (PSI) Maximum Flow U.S.GPM.5 1 2 5 50 0 0 500 1 2 3 5 30 50 0 0 300 500 00 00 L/min Page Direct High Speed Linear Servo Valves LSVG-03

More information

Electric amplifier for flow control with proportional

Electric amplifier for flow control with proportional Electric amplifier for flo control ith proportional valves RE 29955/07.14 Replaces: 09.11 1/8 Type VT 5035 Component series 1X H5581 Table of contents Content Page eatures 1 Ordering code 2 unctional description

More information

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces: Valve amplifier for proportional valves Type VT-MSPA2-1 RE 30228 Edition: 2014-01 Replaces: 2011-04 Component series 1X Suitable for controlling direct operated proportional directional valves without

More information

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features Valve amplifier for high-response valves Type VT-VRRA1-527-2X/V0/2STV, VT-VRRA1-527-2X/V0/PO-IS RE 30045 Edition: 2013-04 Replaces: 02.12 Component series 2X Analog, euro-card format Suitable for controlling

More information

DIN (NFPA/ISO/CETOP) NG6 (03) NG10

DIN (NFPA/ISO/CETOP) NG6 (03) NG10 Catalog HY14-255/ echnical Information eries D*FH and D1FM General Description he D*FH series high response proportional servovalves are direct solenoid operated, with electronic spool position feedback

More information

Compact Hydraulic System for Energy Savings and High Precision. POWER Meister

Compact Hydraulic System for Energy Savings and High Precision. POWER Meister Compact Hydraulic System for Energy Savings and High Precision POWER Meister POWER Meister Compact Hydraulic System Superior Energy Savings High Precision AC servo motor controls rotational speed and direction

More information

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents Valve amplifier for proportional directional valves and proportional pressure valves Type VT-VSPA2-1 RE 30110 Edition: 2013-04 Replaces: 05.12 Component series 2X Analog, euro-card format Suitable for

More information

DIN (NFPA/ISO/CETOP) NG6 (3) NG10

DIN (NFPA/ISO/CETOP) NG6 (3) NG10 Technical nformation General escription proportional directional control valves are direct operated solenoid valves with electronic spool position feedback, and on-board integrated control electronics.

More information

PROPORTIONAL PRESSURE CONTROLS TECNORD

PROPORTIONAL PRESSURE CONTROLS TECNORD Proportional Pressure Reducing / Relieving Valves Direct acting GPM PSI LPM BAR MODEL PAGE 0,8 5000 3 345 IP-DAR-43-H 8 0,8 700 3 50 IP-DAR-43-L 8 2 500 8 35 EC PRV 10 Pilot operated GPM PSI LPM BAR MODEL

More information

LSV(H)G Series High-speed Linear Servo Valves

LSV(H)G Series High-speed Linear Servo Valves LSV(H)G Series High-speed Linear Servo Valves LSVG-03 (3/8) & LSVHG-04/06/10 (1/2,3/4,1) Sub-plate Mounting LSVG/LSVHG Series High-Speed Linear Servo Valves offer extremely high response and excellent

More information

Generator Speed Controller Model GSC 1

Generator Speed Controller Model GSC 1 enerator Speed Controller odel SC 1 RA 29 977/09.95 Replaces: 4.92 Self contained controller for driving electrical power generators with a hydrostatic transmission 16 Bit microprocessor based controller

More information

Proportional Directional Valves with Feedback KBFDG4V-5-2C75N45-Z-M1-PC7-H7-12-EN123/EN150. Pressures to 315 bar (4500 psi)

Proportional Directional Valves with Feedback KBFDG4V-5-2C75N45-Z-M1-PC7-H7-12-EN123/EN150. Pressures to 315 bar (4500 psi) Proportional Directional Valves with Feedback KBFDG4V-5-2C75N45-Z-M1-PC7-H7-12-EN123/EN150 Pressures to 315 bar (4500 psi) Contents GENERAL DESCRIPTION... 03 SPOOL DATA... 03 FUNCTIONAL SYMBOL.... 03 MODEL

More information

R30D RVDTs DC-Operated Rotary Variable Differential Transformers

R30D RVDTs DC-Operated Rotary Variable Differential Transformers R30D RVDTs DC-Operated Rotary Variable Differential Transformers RVDTs incorporate a proprietary noncontact design that dramatically improves long term reliability when compared to other traditional rotary

More information

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6 Electric amplifiers RE 30048/08.12 Replaces: 03.12 1/6 Type VT-VRPA2-5...-1X/V0/RTP Component series 1X Table of contents Contents Page Features 1 Ordering code, accessories 2 Front plate 2 Block diagram

More information

FAS 10 mm PICOSOL Direct acting solenoid valve

FAS 10 mm PICOSOL Direct acting solenoid valve FS 0 mm PICOSOL > > /, /; Manifold mounting > > Long life 00 million cycles > > Compact Design > > Low power consumption Technical features Medium: ir, oxygen, neutral gases (0 %... 9 % humidity, non condensing),

More information

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces: Valve amplifier for proportional valves Type VT-SSPA- (5, 50, 00, 50) RE 306 Edition: 05-03 Replaces: 04-07 Component series X Analog, connector design Suitable for controlling solenoid-actuated pressure

More information

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Type WRPEH RE 9 Edition: 8- Replaces: 7-5 Size 6 Component series 3X Maximum operating pressure

More information

High-response valve with integrated digital axis controller (IAC-R) and field bus interface

High-response valve with integrated digital axis controller (IAC-R) and field bus interface High-response valve with integrated digital axis controller (IAC-R) and field bus interface RE 99/09.0 Replaces: 06.05 / Type 4WRPNH.../4C... Type 4WRPNH.../4P... Size 6 and 0 Component series X Maximum

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 10770-2 Second edition 2012-12-01 Hydraulic fluid power Electrically modulated hydraulic control valves Part 2: Test methods for three-port directional flow-control valves Transmissions

More information

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable)

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable) T E M P O S O N I C S L S E R I E S INSTALLATION A N A L O G O U T P U T 550570 B W I R I N G - A N A L O G O U T P U T S RG Connector: (Voltage or Current Output) 1 Gray 0 to 10 Vdc, 4 to 20 ma, or 0

More information

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w) 89 610/112 ED EWM-A-SV ANALOG AMPLIFIER CARD SERVOVALVE CONTROL RAIL MOUNTING TYPE: DIN EN 50022 OPERATING PRINCIPLE This card is designed for a dynamic control of servovalves with the current output controlled

More information

Eaton Servo-Performance Proportional Directional Valve AxisPro. KBH*-8 10 Series

Eaton Servo-Performance Proportional Directional Valve AxisPro. KBH*-8 10 Series Eaton Servo-Performance Proportional Directional Valve AxisPro KBH*-8 10 Series Contents Introduction General Description... 3 Typical Section View... 3 Model Code... 4 Spool Data... 6 Operating Data...

More information

Box chopper amplifier BOE

Box chopper amplifier BOE Box chopper amplifier BOE Description The box chopper amplifier is an always energised Pulse-Wide-Modulated (PWM) H-Bridge for to drive inductive loads with bipolar current in according to an analogue

More information

Electrohydraulic Actuator Type PVEP / PVEP-F

Electrohydraulic Actuator Type PVEP / PVEP-F MAKING MODERN LIVING POSSIBLE Technical Information Electrohydraulic Actuator Type PVEP / PVEP-F powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev May 2014 Converted to Danfoss

More information

Eaton Servo-Performance Proportional Directional Valve AxisPro. KBH Series

Eaton Servo-Performance Proportional Directional Valve AxisPro. KBH Series Eaton Servo-Performance Proportional Directional Valve AxisPro KBH-7 1 Series Contents Introduction General Description Typical Section View 3 Model Code 4 Spool Sleeve Details 5 Spool Data 6 Performance

More information

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6 Electric amplifiers RE 30052/02.12 Replaces: 01.09 1/6 Type VT-VRPA1-5...-1X/V0/... Component series 1X Table of contents Contents Page Features 1 Ordering code, accessories 2 Front plate 2 Block diagram

More information

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8 Plug-in amplifier RE 30264/07.12 Replaces: 03.10 1/8 Type VT-SSPA1 Component series 2X Table of contents Contents Page Features 1 Ordering code, accessories 2 Function 3 Connections and adjustment 3 Block

More information

Service Parts List AA4V90

Service Parts List AA4V90 Service Parts List AA4V90 Series 1 06.96 Ordering of AA4V Parts For Rexroth to supply the correct parts for your unit, please include all of the following information with your parts order. TYPE CODE TYPE

More information

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Analog Amplifier RA RE 95 230/03.06 1/12 replaces: RE 95 022 RE 95 023 RE 29 874 RE 29 875 Technical Data

More information

Direct Drive Digital Control

Direct Drive Digital Control Direct Drive Digital Control Servo Valves PreSSUre (p) and PreSSUre-FloW (pq) control D638 SIZE 3 D639 SIZE 5 High-performance pressure control with higher dynamics and the ability to easily and exactly

More information

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module / - ; 0 PSI Advantages / Benefits Wireless easy mounting and dismounting of sensor head by a Turn & Lock technique 3-wire Hall version to interface directly with PLC's (both NPN and PNP) Easy to connect:

More information

BFS / BFSM SERIES Installation & Maintenance Manual

BFS / BFSM SERIES Installation & Maintenance Manual Introduction: The BFS / BFSM series electric actuators have battery backup modules for fail safe operation. The BFS series is for two position control and the BFSM series is for proportional control, both

More information

Eaton Servo-Performance Proportional Directional Valve AxisPro. KBH Series

Eaton Servo-Performance Proportional Directional Valve AxisPro. KBH Series Eaton Servo-Performance Proportional Directional Valve AxisPro KBH-5 1 Series Contents Introduction General Description Typical Section View 3 Model Code 4 5 Spool Sleeve Details 6 Spool Data 7 Pressure

More information

Omar E ROOD 1, Han-Sheng CHEN 2, Rodney L LARSON 3 And Richard F NOWAK 4 SUMMARY

Omar E ROOD 1, Han-Sheng CHEN 2, Rodney L LARSON 3 And Richard F NOWAK 4 SUMMARY DEVELOPMENT OF HIGH FLOW, HIGH PERFORMANCE HYDRAULIC SERVO VALVES AND CONTROL METHODOLOGIES IN SUPPORT OF FUTURE SUPER LARGE SCALE SHAKING TABLE FACILITIES Omar E ROOD 1, Han-Sheng CHEN 2, Rodney L LARSON

More information

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6 89 500/110 ED EWM-P-AA DIGITAL CARD FOR PRESSURE AND FORCE CONTROL IN CLOSED LOOP SYSTEMS RAIL MOUNTING TYPE: DIN EN 50022 OPERATING PRINCIPLE The EWM-P-AA has been developed for pressure closed loop control

More information

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20 89 220/101 ED EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES EPA-M1** single solenoid EPA-M2** double solenoid EPA-M3** 2 independent channels single solenoid valves RAIL MOUNTING TYPES: DIN

More information

Electric amplifiers. List of contents. Features. RE 30052/08.05 Replaces: Type VT-VRPA1. Unit series 1X 1/6

Electric amplifiers. List of contents. Features. RE 30052/08.05 Replaces: Type VT-VRPA1. Unit series 1X 1/6 Electric amplifiers RE 30052/08.05 Replaces: 05.04 1/6 Type VT-VRPA1 Unit series 1X List of contents Contents Page Features 1 Ordering data 2 Preferred types 2 Front panel 3 Circuit diagram with pin assignment

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer IN 1000-S N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)

More information

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6 Electric amplifiers RE 30054/03.12 Replaces: 01.09 1/6 Type VT-VRPA1-5...-1X/...-RTP Component series 1X Table of contents Contents Page Features 1 Ordering code, accessories 2 Front plate 2 Block diagram

More information

Analog amplifier RA. RE Edition: Replaces:

Analog amplifier RA. RE Edition: Replaces: Analog amplifier RA RE 950 Edition: 08.05 Replaces: 0.006 For control of simple functions of electrohydraulic components Two power outputs (PWM) and one switching output Each output has a separately adjustable

More information

TPV 1500 VARIABLE DISPLACEMENT AXIAL PISTON PUMP

TPV 1500 VARIABLE DISPLACEMENT AXIAL PISTON PUMP VRILE DISPLCEMENT XIL PISTON PUMP Variable Displacement xial Piston Pump ORDER CODE 0 1 17-9 2 CR 3 SS3 4 F2 5 SHI 6 O 7 10 8 06 9 S-R 10 000 11 1 12 00 13 Pag. 0 - Pump series = Pump 1 - Pump model =

More information

Insertion Flow sensor for continuous flow measurement

Insertion Flow sensor for continuous flow measurement Insertion Flow sensor for continuous flow measurement Economic integration into pipe systems 2 wire frequency coil (sinusoidal) version 3 wire frequency Hall effect (pulse) version to directly interface

More information

Proportional Directional Control Valves Series D1FB. General Description. Features. D1FB*3 OBE Spool/Body Design. D1FB*0 OBE Spool/Sleeve Design

Proportional Directional Control Valves Series D1FB. General Description. Features. D1FB*3 OBE Spool/Body Design. D1FB*0 OBE Spool/Sleeve Design echnical Information roportional Directional Control Valves Series D1FB General Series D1FB (NG6) proportional directional valves are available with and without onboard electronics (OBE). D1FB OBE: he

More information

Electric amplifiers. Table of contents. Features RA 30052/ Model VT-VRPA1. Series 1X 1/6

Electric amplifiers. Table of contents. Features RA 30052/ Model VT-VRPA1. Series 1X 1/6 Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Electric amplifiers RA 30052/05.04 1/6 Model VT-VRPA1 Series 1X Table of contents Contents Page Features

More information

Disc Gap Control DGC-2. Technical Manual

Disc Gap Control DGC-2. Technical Manual GB Disc Gap Control DGC-2 Technical Manual Contents Introduction Electronic unit... 1 Tracer valve... 1 Technical data... 2 Component layout... 4 Functions, electronic unit Stepper motor operation...

More information

Mobile dual solenoid driver

Mobile dual solenoid driver Electric Drives and Controls Hydraulics Linear Motion and ssembly Technologies Pneumatics Service Mobile dual solenoid driver R 864/0.0 Replaces: 06.8 /6 Model MDSD Component series X Table of contents

More information

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM

More information

Smart Power Relay E I...

Smart Power Relay E I... Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic

More information

Electric amplifier for proportional cartridge throttle valves

Electric amplifier for proportional cartridge throttle valves Electric amplifier for proportional cartridge throttle valves RE 30053/09.05 1/8 Type VT-VRPA1-527-2X/V0/RTS-2/2V Unit series 2X List of contents Contents Page Features 1 Ordering data 2 Preferred types

More information

SAFETY PRECAUTIONS GENERAL INFORMATION

SAFETY PRECAUTIONS GENERAL INFORMATION Form No. 102831 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.hytec.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800)

More information

Directional control valve, direct operated, with integrated digital axis controller (IAC-Multi-Ethernet) Type 4WRPDH. Features.

Directional control valve, direct operated, with integrated digital axis controller (IAC-Multi-Ethernet) Type 4WRPDH. Features. Directional control valve, direct operated, with integrated digital axis controller (IAC-Multi-Ethernet) Type 4WRPDH RE 29391 Edition: 2015-01 Replaces: 2014-10 Sizes 6 and 10 Component series 2X Maximum

More information

Continental Hydraulics Installation Manual CEM-PA-A

Continental Hydraulics Installation Manual CEM-PA-A CEMPAA Description: This closed loop PID amplifier drives a single solenoid proportional pressure or flow control valve coil up to 2.6A. It is suitable to provide precise closed loop control in pressure,

More information

MS Connector: (Voltage or Current Output) Pin No. Extension Cable Function. Wire Color. MS Connector: (Start/Stop or PWM) Wire Color WIRING: + A

MS Connector: (Voltage or Current Output) Pin No. Extension Cable Function. Wire Color. MS Connector: (Start/Stop or PWM) Wire Color WIRING: + A T E M P O S O N I C S L S e r i e s INSTALLATION T E M P O S O N I C S L D W I R I N G 550653 C INTEGRAL CABLES: INTEGRAL CABLES WITH HANGING MS CONNECTOR: R Cable w/pigtail Termination: (Voltage or Current

More information

400 (±2,5 V/ V/ ,3% V4A

400 (±2,5 V/ V/ ,3% V4A LVDT Inductive Position Transducer - Hydraulic Series Series Hydraulic position measurement in hydraulic cylinders of machine controls ranges 10...300 mm temperature -40...+150 C (sensors) 0...+60 C (external

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors M-Series Mobile Hydraulic in-cylinder Sensor Model MH PWM Output Data Sheet SENSORS Document Part Number 551119 Revision B M-Series

More information

User Manual. Proportional Directional Control Valve PRM7

User Manual. Proportional Directional Control Valve PRM7 Proportional Directional Control Valve PRM7 User Manual Content Obsah 1. General technical parameters... 2 1.1. Introduction... 2 1.2. Valves Usage... 2 1.3. Limited Warranty... 2 1.4. Used Symbols...

More information

3.0 CHARACTERISTICS. Type CKO Overcurrent Relay. switch, which allows the operation indicator target to drop.

3.0 CHARACTERISTICS. Type CKO Overcurrent Relay. switch, which allows the operation indicator target to drop. 41-101.3A Type CKO Overcurrent Relay switch, which allows the operation indicator target to drop. The front spring, in addition to holding the target, provides restraint for the armature and thus controls

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer ITN 1000-S ULTRASTAB I PM = 1000 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)

More information

VP60. 5/3 Way proportional directional control valves Nominal diameter 8 direct operated sliding valves with µp-driven position control

VP60. 5/3 Way proportional directional control valves Nominal diameter 8 direct operated sliding valves with µp-driven position control / Way proportional directional control valves Nominal diameter 8 direct operated sliding valves with µp-driven position control Adjusted, linear flow characteristic Zero-overlap-characteristic High flow

More information

Valve amplifier for proportional pressure valves

Valve amplifier for proportional pressure valves Valve ampliier or proportional pressure valves Type VT-VSPA1-2 RE 30115 Edition: 2013-09 Replaces: 2013-02 Component series 1X Analog, Euro-card ormat Suitable or controlling proportional pressure valves:

More information

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features: LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement range

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 700-S ULTRASTAB I PM = 700 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)

More information

ValveExpert. Check / Adjust / Repair Servo- and Proportional Valves

ValveExpert. Check / Adjust / Repair Servo- and Proportional Valves ValveExpert Check / Adjust / Repair Servo- and Proportional Valves Automatic Test Stand Contents INTRODUCTION... 4 REVIEW OF SPECIFICATIONS... 5 APPLICATIONS... 5 CONTROL SIGNALS... 5 AMPLIFIER FOR PROPORTIONAL

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current Transducer IN 1000-S I P N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)

More information

/2 way motorised valves

/2 way motorised valves 8880 / way motorised valves >> ort size: G/... >> Low power consumption >> Wearresistant ceramic rotary action sliding plate >> Valve remains on last setting if power lost >> Will handle contaminated fluids

More information

LPK1550 Hydraulic Crimping Tool 15-ton

LPK1550 Hydraulic Crimping Tool 15-ton SERVICE MANUAL LPK1550 Hydraulic Crimping Tool 15-ton Serial Code FYF Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register

More information

Flush pressure transmitter For viscous and solids-containing media Model S-11

Flush pressure transmitter For viscous and solids-containing media Model S-11 Electronic pressure measurement Flush pressure transmitter For viscous and solids-containing media Model S-11 WIKA data sheet PE 81.02 Applications Machine building Hydraulic aggregates General industrial

More information