3 Description of Version Edition No. Data of Revision Revision Summary Report No. 0 February 07, 2017 Original Report BWS-17-EC-0015 This Test Report shall not be reproduced, except in full, without the written approval of the BWS TECH Inc. This document may. Be altered or revised by BWS TECH Inc. personnel only, and shall be noted in the revision section of the document. Any alteration of this document not carried out by BWS TECH Inc. will constitute fraud and shall nullify the document. Page Number : Page 2 of 51

4 TABLE OF CONTENTS Description of Version 3 1. General Description of EUT General Information of Test Conducted Emission Tests Radiated Emission Tests Radiated Electromagnetic disturbance Test Power Frequency Harmonics and Flicker Emission Tests Electrostatic Discharge Immunity Test Radiated, radio-frequency, electromagnetic field immunity test Electrical fast transient/burst immunity test Surge immunity test Conducted immunity test Voltage Dips and Short interruptions immunity test EUT Photographs Page Number : Page 3 of 51

5 1. General Description of EUT 1.1 Applicant Company Name : SoluM Co., Ltd. Address : Contact Person : Ki-Dong Lee 150, Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, Republic of Korea E mail : kdlee007@solu-m.com Phone / FAX : TEL : FAX : Manufacturer Company Name : SoluM Co., Ltd. Address : Contact Person : Ki-Dong Lee 150, Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, Republic of Korea E mail : kdlee007@solu-m.com Phone / FAX : TEL : FAX : Factory Factory 1 : Dongguan Solum Electronics Co., Ltd. Address : Hengkeng Management Area, Liaobu Town, Dongguan City, Guangdong Province , People s Republic of China Factory 2 : Dongguan Aptech Electronics Co., Ltd. Address : Jinfu 2 Road, TangChun East Area, TangChun Village, LiaoBu Town DongGuan City, GuangDong Province, People's Republic of China Factory 3 : Dongguan Yingju Power Co., Ltd. Address : No.6 Yongxing Road, Shayao Village, Shijie Town, Dongguan City, Guangdong Province, , People s Republic of China Factory 4 : SOLUM VINA COMPANY LIMITED Address : Plot B3, Bathien 2 Industrial Park, Thien Ke Ward, Binh Xuyen District, Vinh Phuc Province, , Vietnam Page Number : Page 4 of 51

6 1.4 Basic Description of EUT Trade Name : Product Name : LED CONVERTER Model Name : OLU201P701U1A ADD Model : OLU201P701U1U, OLU201P701N1A, OLU201P701N1U Serial Number : Prototype Test Voltage : AC 230 V, 50 Hz Rating : PRI Input: AC ( ) V, 50/60 Hz, 2.0 A, 210 W SEC Output: DC ( ) V, 0.7 A, 185 W Page Number : Page 5 of 51

7 2. General Information of Test 2.1 Test Facility This test was carried out by BWS TECH Inc. Test Site Location : 23, Gokhyeon-ro 480 Beon-gil, Mohyeon-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do , Korea TEL : FAX : Standard for Methods of Measurement Basic Standard Description Test Result EN 55015:2013 EN 61547:2009 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment Equipment for general lighting purposes EMC immunity requirements Pass Pass Fail Fail EN :2014 Mains harmonics equipment up to 16A. Pass Fail EN :2013 Voltage fluctuations equipment up to 16A. Pass Fail EN :2009 EN :2006+A2:2010 EN :2012 Testing and measurement techniques. Electrostatic discharge immunity test. Testing and measurement techniques. Radiated Immunity. Testing and measurement techniques. Electrical fast transient/burst immunity test. EN :2014 Testing and measurement techniques. Surge immunity test. Pass Fail EN :2014 Testing and measurement techniques. Immunity to conducted disturbances induced by Pass Fail radio frequency fields. EN :2010 Testing and measurement techniques. Power frequency magnetic field Immunity Test. N/A #Note 1 EN :2004 Testing and measurement techniques. Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests. Pass Fail #Note 1. This test was excluded, because EUT was not containing any devices susceptible to magnetic fields. 2.3 Description of EUT Modification - N/A Pass Pass Pass Fail Fail Fail Page Number : Page 6 of 51

8 2.4 Model Difference Classification Model Name Difference 1 Basic model OLU201P701U1A Dimming 2 OLU201P701U1U Dimming 3 Series models OLU201P701N1A Non Dimming (UL Model) 4 OLU201P701N1U Non Dimming (UL Model) Difference between basic model and series model - Identical to the basic model except for dimmer cable. 2.5 Additional information related to Testing Test results apply only to the particular sample tested and functionality described in this test report. This report may be reproduced in full. Partial reproduction may only be made with the written permission of the BWS Tech Inc. 2.6 Test Conditions EUT Operating Mode EUT was tested according to the following operation modes provided by the specifications given by the manufacturer, and reported the worst emissions. Operation Modes Worst Case Mode Normal Operation Mode Performance Criteria A) Performance Criterion A During the test, no change of the luminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended. B) Performance Criterion B During the test, the luminous intensity may change to any value. After the test, the luminous intensity shall be restored to its initial value within 1 min. Regulating controls need not function during the test, but after the test the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given. C) Performance Criterion C During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control Page Number : Page 7 of 51

9 Test System layout on EUT and peripherals Interface cable Power cable EUT DIM Lever LED Jig 2.7 Description of Test System (EMI and EMS) Type of Peripheral Equipment Used: Description Model Name Serial No. Manufacturer EUT OLU201P701U1A Prototype SoluM Co., Ltd. LED Jig N/A N/A N/A DIM Lever NTSTV-DV N/A N/A Type of Cables Used: Device from I/O Port Device to I/O Port Length(m) Type of Shield AC IN AC Power Socket AC OUT 1.2 Unshielded EUT DC OUT LED Jig DC IN 0.3 Unshielded DIM DIM Lever DIM 0.8 Unshielded Page Number : Page 8 of 51

10 3.1 Conducted Emission Tests Conducted Emissions were measured from 9 khz to 150 khz with a bandwidth of 200 Hz, 150 khz to 30 MHz with a bandwidth of 9 khz on the 230 V AC power and return leads of the EUT according to the methods defined in European Standard EN 55015:2013 Clause 8. The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown in section The interface cables and equipment positioning were varied within limits of reasonable applications to determine the position producing maximum conducted emissions Test Condition Test Standard Frequency Range of Test : 9 khz to 30 MHz Test Standard : EN 55015:2013 Test Date : February 06, 2017 Temperature/Humidity : 18 C / 38 % R.H. Item Main Terminal Frequency Range Limit db(uv) (MHz) Quasi-Peak Average-Peak to to to Item Control Terminal Frequency Range Limit db(uv) (MHz) Quasi-Peak Average-Peak to to Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use EMI Test Receiver ESR ROHDE & SCHWARZ LISN LN2-16N EMCIS LN HIGH VOLTAGE PROBE TK9420 SCHWARZBECK Page Number : Page 9 of 51

11 3.1.4 Test Result of Conducted Emission EUT : OLU201P701U1A Input Voltage : AC 230 V, 50 Hz Test Mode : Maximum light output level L1 Conducted Emission Test Results: PASS Test data sheets follow. Conducted Emission Test Data Page Number : Page 10 of 51

12 EUT : OLU201P701U1A Input Voltage : AC 230 V, 50 Hz Test Mode : Maximum light output level N Conducted Emission Test Results: PASS Test data sheets follow. Conducted Emission Test Data Page Number : Page 11 of 51

13 EUT : OLU201P701U1A Input Voltage : AC 230 V, 50 Hz Test Mode : Maximum light output level DIM Conducted Emission Test Results: PASS Test data sheets follow. Control Terminal Conducted Emission Test Data Page Number : Page 12 of 51

14 EUT : OLU201P701U1A Input Voltage : AC 230 V, 50 Hz Test Mode : Minimum light output level L1 Conducted Emission Test Results: PASS Test data sheets follow. Conducted Emission Test Data Page Number : Page 13 of 51

15 EUT : OLU201P701U1A Input Voltage : AC 230 V, 50 Hz Test Mode : Minimum light output level N Conducted Emission Test Results: PASS Test data sheets follow. Conducted Emission Test Data Page Number : Page 14 of 51

16 EUT : OLU201P701U1A Input Voltage : AC 230 V, 50 Hz Test Mode : Minimum light output level DIM Conducted Emission Test Results: PASS Test data sheets follow. Control Terminal Conducted Emission Test Data Notes 1. Margin = Limit - Emission Level 2. All modes of operation were investigated and the worst-case emissions are reported. See the photos in next pages. 3. Measurement uncertainty estimated at 3.72 db. The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = The EUT was independent transformers and convertors for LED lamps. So, Insertion loss test was not applied. Page Number : Page 15 of 51

17 3.1.5 Photographs of Conducted Emission Test Configuration [Conducted Emission Test-Main Terminals] Page Number : Page 16 of 51

18 [Conducted Emission Test-Control Terminal] Page Number : Page 17 of 51

19 3.2 Radiated Emission Tests Radiated emissions form 30 MHz to 300 MHz were measured with a bandwidth of 120 khz according to the methods defines in EN 55015:2013. The EUT was placed on a nonmetallic stand in the 10 m chamber, 0.8 meter above the ground plane, as shown in section The interface cables and equipment positions were varied within limits of reasonable applications to determine the positions producing maximum radiated emissions Test Condition Frequency Range of Test : 30 MHz to 300 MHz Test Standard : EN 55015:2013 Test Date : February 06, 2017 Temperature/Humidity : 16 C / 37 % R.H Test Standard Frequency Range (MHz) Limit (dbuv) Quasi-Peak 30 ~ ~ Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Bilog Antenna VULB 9160 SCHWARZBECK EMI Test Receiver ESR ROHDE & SCHWARZ RF AMPLFIER MPA RF Bay Antenna Mast ( 4 m) AM 4.0 MATURO Positioner Controller CO2000 MATURO AM4.0/225/ NCU/459/ N/A N/A Page Number : Page 18 of 51

20 3.2.4 Test Result of Radiated Emission EUT : OLU201P701U1A Test distance : Maximum light output level 10 m Radiated Emission Test Results : PASS Test data sheets follow. Radiated Emission Test Data Page Number : Page 19 of 51

21 EUT : OLU201P701U1A Test distance : Minimum light output level 10 m Radiated Emission Test Results : PASS Test data sheets follow. Radiated Emission Test Data Notes 1. * H : Horizontal polarization, ** V : Vertical polarization 2. Margin value = Emission Level Limit (QuasiPeak) 3. Corr. = Correction factor (Antenna factor + Cable loss AMP gain) 4. Measurement uncertainty estimated at 5.49 db. The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2. Page Number : Page 20 of 51

22 3.2.5 Photographs of Radiated Emission Test Configuration [Radiated Emission Test] Page Number : Page 21 of 51

23 3.3 Radiated Electromagnetic disturbance Test Radiated emissions form 9 khz to 30 MHz were measured with a bandwidth of 200 Hz, 9 khz according to the methods defines in EN 55015:2013. The EUT was placed on a nonmetallic stand as shown in section Test Condition Frequency Range of Test : 9 khz to 30 MHz Test Standard : EN 55015:2013 Test Date : February 06, 2017 Loop Antenna Size : 2 m Temperature/Humidity : 20 C / 31 % R.H Test Standard Frequency Range (MHz) Quasi-Peak Limit (dbuv) Average-Peak N/A to 58 N/A to 26 N/A N/A Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Loop Antenna HXYZ 9170 SCHWARZBECK HXYZ N/A EMI Test Receiver ESPI ROHDE & SCHWARZ Page Number : Page 22 of 51

24 3.3.4 Test Result of Radiated Emission EUT : OLU201P701U1A Loop Antenna Size : 2 m Test mode : Maximum light output level X-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Page Number : Page 23 of 51

25 EUT : OLU201P701U1A Loop Antenna Size : 2 m Test mode : Maximum light output level Y-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Page Number : Page 24 of 51

26 EUT : OLU201P701U1A Loop Antenna Size : 2 m Test mode : Maximum light output level Z-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Page Number : Page 25 of 51

27 EUT : OLU201P701U1A Loop Antenna Size : 2 m Test mode : Minimum light output level X-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Page Number : Page 26 of 51

28 EUT : OLU201P701U1A Loop Antenna Size : 2 m Test mode : Minimum light output level Y-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Page Number : Page 27 of 51

29 EUT : OLU201P701U1A Loop Antenna Size : 2 m Test mode : Minimum light output level Z-axis Radiated Electromagnetic disturbance Test Results: PASS Test data sheets follow. Radiated Electromagnetic disturbance Test Data Notes 1. Margin value = Limit - Emission Level 2. All other emissions not reported were more than 25 db below the permitted limit. 3. Measurement uncertainty estimated at 2.99 db. The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2. Page Number : Page 28 of 51

30 3.3.5 Photographs of Radiated Electromagnetic disturbance Test. [Radiated Electromagnetic disturbance Test] Page Number : Page 29 of 51

31 3.4 Power Frequency Harmonics and Flicker Emission Tests Test Procedure Power Frequency Harmonics Tests : The measured values of the harmonics components of the input current, including line current and neutral current, shall be compared with the limits given in Clause 7 of EN :2014 Flicker Emission Tests : The total impedance of the test circuit, excluding the appliance under test, but including the internal impedance of the supply source, shall be equal to the reference impedance. The stability and tolerance of the reference impedance shall be adequate to ensure that the overall accuracy of 8 % is achieved during the whole assessment procedure Test Condition EUT : OLU201P701U1A Test Standard : EN :2014 EN :2013 Test Date : February 06, 2017 Device Class : C Temperature/Humidity : 23 C / 35 % R.H Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compliance Test System PACS-1 California Instruments N/A AC Power Source 5001IX California Instruments Test Result of Power Frequency Harmonics and Flicker Emission Tests Power Frequency Harmonics : PASS Flicker Emission Tests : PASS Page Number : Page 30 of 51

32 V o l t a g e ( V o l t s ) Harmonics Class-C (Run time) EUT: OLU201P701U1A Tested by: BWS TECH Inc. Test category: Class-C (European limits) Test Margin: 100 Test duration (min): 3 Customer: SoluM Co., Ltd. Test Result: Pass C u r r e n t ( A m p s ) Current & voltage waveforms C u r r e n t R M S ( A m p s ) Harmonics and Class C limit line Source qualification: Normal European Limits H a r m o n i c # Test result: Pass Worst harmonics H % of 100% limit, H % of 150% limit. Page Number : Page 31 of 51

33 Current Test Result Summary (Run time) EUT: OLU201P701U1A Tested by: BWS TECH Inc. Test category: Class-C (European limits) Test Margin: 100 Test duration (min): 3 Customer: SoluM Co., Ltd. Test Result: Pass Source qualification: Normal THC(A): 0.05 I-THD(%): 5.79 POHC(A): POHC Limit(A): Highest parameter values during test: V_RMS (Volts): Frequency(Hz): I_Peak (Amps): I_RMS (Amps): I_Fund (Amps): Crest Factor: Power (Watts): Power Factor: Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Note: Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the same window as the maximum harmonics/limit ratio. Page Number : Page 32 of 51

34 Voltage Source Verification Data (Run time) EUT: OLU201P701U1A Tested by: BWS TECH Inc. Test category: Class-C (European limits) Test Margin: 100 Test duration (min): 3 Customer: SoluM Co., Ltd. Test Result: Pass Source qualification: Normal Highest parameter values during test: Voltage (Vrms): Frequency(Hz): I_Peak (Amps): I_RMS (Amps): I_Fund (Amps): Crest Factor: Power (Watts): Power Factor: Harm# Harmonics V-rms Limit V-rms % of Limit Status OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK Page Number : Page 33 of 51

35 1 0 : 4 9 : : 4 9 : 2 3 Flicker (Run time) EUT: OLU201P701U1A Tested by: ks.yoon Test category: All parameters (European limits) Test Margin: 100 Test duration (min): 10 Customer: SoluM Co., Ltd. Test Result: Pass Psti and limit line Status: Test Completed European Limits P s t Plt and limit line P l t Parameter values recorded during the test: Vrms at the end of test (Volt): Highest dt (%): 0.00 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (ms): Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.00 Test limit (%): 4.00 Pass Highest Pst (10 min. period): Test limit: Pass Highest Plt (2 hr. period): Test limit: Pass Page Number : Page 34 of 51

36 3.4.5 Photographs of Power Frequency Harmonics and Flicker Emission Tests Configuration. [Power Frequency Harmonics and Flicker Emission Tests- Harmonics] [Power Frequency Harmonics and Flicker Emission Tests- Flicker] Page Number : Page 35 of 51

37 3.5 Electrostatic Discharge Immunity Test In order to minimize the impact of environmental parameters on test results, the tests shall be carried out in climatic and electromagnetic reference conditions as specified in EN 61547:2009. The test programs and software shall be chosen so as to exercise all normal modes of operation of the EUT. The use of special exercising software is encouraged, but permitted only where it can be shown that the EUT is being comprehensively exercised. The testing shall be performed by direct and indirect application of discharges to the EUT according to a test plan Test Condition EUT : OLU201P701U1A Test Standard : EN 61547:2009 Test Method : EN :2009 Test Date : February 06, 2017 Test Voltage : Contact 4 kv, Air (2,4,8) kv Performance criterion : B Temperature/Humidity/Pressure : 24 C / 36 % R.H. / kpa Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use ESD Simulator EDS30V 3CTEST ES Test Result of Electrostatic Discharge Immunity Test Electrostatic Discharge Immunity Test : PASS The equipment meets the requirements. Page Number : Page 36 of 51

38 Test data sheet follows. Test Point Discharge Type CD=Contact AD=Air Test Voltage(kV) Tested No Observation Result VCP CD 4 kv Each 10 times Normal PASS (A) HCP CD 4 kv Each 10 times Normal PASS (A) EUT Metal Case CD 4 kv Each 10 times Normal PASS (A) EUT Screw CD 4 kv Each 10 times Normal PASS (A) EUT Rubber AD (2,4,8) kv Each 10 times Normal PASS (A) [Test Point] AD CD Front Top Side Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode Page Number : Page 37 of 51

39 3.5.4 Photographs of Electrostatic Discharge Immunity Test Configuration [Electrostatic Discharge Immunity Test] Page Number : Page 38 of 51

40 3.6 Radiated, radio-frequency, electromagnetic field immunity test Tests were conducted in accordance with EN 61547:2009 over the frequency range of 80 MHz to MHz. The transmitting antenna was located 3 meters from the EUT at a height of 1 meter above the floor. Front, sides and back of the EUT were exposed to a uniform field of 3 V/m using both horizontal and vertical antenna polarizations Test Condition EUT : OLU201P701U1A Test Standard : EN 61547:2009 Test Method : EN :2006+A2:2010 Test Date : February 06, 2017 Test field strength (V/m) : 3 V/m Performance criterion : A Temperature/Humidity/Pressure : 23 C / 34 % R.H. / kpa Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Signal Generator SME06 ROHDE & SCHWARZ / RF Power Amplifier ITA0300KL-500 Infinitech N/A RF Power Amplifier ITA0750KL-500 Infinitech N/A Log periodic Antenna K9128 Airlinklab N/A Test Result of Radiated, radio-frequency, electromagnetic field immunity test Electromagnetic field immunity test : PASS The equipment meets the requirements. Page Number : Page 39 of 51

41 Test data sheet follows. Frequency Range (MHz) Position (Angle) Antenna Polarity Field Strength (V/m) Modulation Result Front Vertical 3 80 % AM (1 khz) PASS (A) Rear Vertical 3 80 % AM (1 khz) PASS (A) Right Vertical 3 80 % AM (1 khz) PASS (A) Left Vertical 3 80 % AM (1 khz) PASS (A) Front Horizontal 3 80 % AM (1 khz) PASS (A) Rear Horizontal 3 80 % AM (1 khz) PASS (A) Right Horizontal 3 80 % AM (1 khz) PASS (A) Left Horizontal 3 80 % AM (1 khz) PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode Photographs of Radiated, radio-frequency, electromagnetic field immunity test Configuration [Radiated, radio-frequency, electromagnetic field immunity test] Page Number : Page 40 of 51

42 3.7 Electrical fast transient/burst immunity test Tests were conducted in accordance with EN 61547:2009. Tests were performed to 1 kv to AC power lines Test Condition EUT : OLU201P701U1A Test Standard : EN 61547:2009 Test Method : EN :2012 Test Date : February 06, 2017 Test Voltage : 1 kv(power lines) Performance criterion : B Temperature/Humidity/Pressure : 24 C / 36 % R.H. / kpa Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compact Immunity Simulator CCS600 3CTEST ES Test Result of Electrical fast transient/burst immunity test Electrical fast transient/burst immunity test : PASS The equipment meets the requirements. Page Number : Page 41 of 51

43 Test data sheet follows. Line Voltage Coupling Inject Time (sec) Result L1-N-PE 1 kv Direct 120 PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode Photographs of Electrical fast transient/burst immunity test Configuration [Electrical fast transient/burst immunity test] Page Number : Page 42 of 51

44 3.8 Surge immunity test Tests were conducted in accordance with EN 61547:2009. Tests were performed to 1.0 kv to AC Line to Line and 2.0 kv to Line to Ground Test Condition Test Voltage Test levels EUT : OLU201P701U1A Test Standard : EN 61547:2009 Test Method : EN :2014 EUT Input : AC 230 V, 50 Hz Test Date : February 06, 2017 Test Voltage : 1.0 kv (Line to Line), 2.0 kv (Line to Ground) Performance criterion : C Temperature/Humidity/Pressure : 24 C / 36 % R.H. / kpa Characteristics Self-ballasted lamps and semi-luminaires Test levels Device Luminaries and independent auxiliaries Input Power 25 W > 25 W Wave-shape data 1.2/50 µs 1.2/50 µs 1.2/50 µs Line to Line 0.5 kv 0.5 kv 1.0 kv Line to Ground 1.0 kv 1.0 kv 2.0 kv Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compact Immunity Simulator CCS600 3CTEST ES Test Result of Surge immunity test Surge immunity test : PASS The equipment meets the requirements. Page Number : Page 43 of 51

45 Test data sheet follows. Line Voltage (kv) Coupling Phase(Degree) Inject (count - min) Result L1-N (0.5, 1.0) kv 18 F 90, times - 5 min PASS (A) L1-PE (0.5, 1.0, 2.0) kv 9 F, 10 Ω 90, times - 5 min PASS (A) N-PE (0.5, 1.0, 2.0) kv 9 F, 10 Ω 90, times - 5 min PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode Photographs of Surge immunity test Configuration [Surge immunity test] Page Number : Page 44 of 51

46 3.9 Conducted immunity test Tests were conducted in accordance with EN 61547:2009. Over the frequency range of 150 khz to 80 MHz. Tests were performed at 3 V on power line Test Condition EUT : OLU201P701U1A Test Standard : EN 61547:2009 Test Method EN :2014 Test Date : February 06, 2017 Test Voltage : 3 V Performance criterion : A Temperature/Humidity/Pressure : 24 C / 36 % R.H. / kpa Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use RF Power Amplifier 75A250 Amplifier Research Signal Generator SMT02 ROHDE & SCHWARZ DE Attenuator 100W6dB N/A N/A CDN FCC-801-M3-16A FCC Test Result of Conducted immunity test Conducted immunity test : PASS The equipment meets the requirements. Page Number : Page 45 of 51

47 Test data sheet follows. Frequency Test port (MHz) Coupling Dwell time Modulation Step Size Result Power CDN (M3) 1 s 80 % AM (1 khz) 1.0 % PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode Photographs of Conducted immunity test Configuration [Conducted immunity test] Page Number : Page 46 of 51

48 3.10 Voltage Dips and Short interruptions immunity test Voltage variations tests were conducted in accordance with EN 61547: Test Condition EUT : OLU201P701U1A Test Standard : EN 61547:2009 Test Method : EN :2004 Test Date : February 06, 2017 Voltage Dip : 70 % (10 period) Short interruptions : 0 % (0.5 period) Performance criterion : 70 % (10 period) - C, 0 % (0.5 period) - B Temperature/Humidity/Pressure : 24 C / 36 % R.H. / kpa Test Equipment List Equipment Type Model Manufacture Serial No Cal Due Date Use Compact Immunity Simulator CCS600 3CTEST ES Test Result of Voltage Dips and Short interruptions immunity test Voltage Dips and Short interruptions immunity test : PASS The equipment meets the requirements. Page Number : Page 47 of 51

49 Test data sheet follows. Test voltage level % Number of periods Angle ( ) Criteria Result , 180 C PASS (A) , 180 B PASS (A) Remarks 1. The primary functions as described below were fully functional during and after test. - Normal Operation Mode Photographs of Voltage Dips and Short interruptions immunity test Configuration [Voltage Dips and Short interruptions immunity test] Page Number : Page 48 of 51

50 4. EUT PHOTOGRAPHS [Front of EUT] [Top of EUT] Page Number : Page 49 of 51

51 [Internal of EUT] Page Number : Page 50 of 51

52 [Front of Main Board] [Rear of Main Board] Page Number : Page 51 of 51

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10 TABLE OF CONTENTS 1. General Description of EUT 3 2. General Information of Test 4-6 3.1 Conducted Emission Tests 7-10 3.2 Radiated Emission Tests 11-13 3.3 Radiated Electromagnetic disturbance Test 14-18

More information

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12 TABLE OF CONTENTS 1. General Description of EUT 3 2. General Information of Test 4-6 3.1 Conducted Emission Tests 7-12 3.2 Radiated Emission Tests 13-15 3.3 Radiated Electromagnetic disturbance Test 16-20

More information

EMC TEST REPORT. According to

EMC TEST REPORT. According to EMC TEST REPORT According to EN 55014-1: 2006 EN 55014-2: 1997+A1:2001 EN 61000-3-2: 2006 EN 61000-3-3: 1995+A1:2001+A2:2005 Test Report No. Equipment : BWS-08-EC-0001 : Air cleaner Model No : AIRVAX 33X2

More information

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 11

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 11 Page : 2 / 38 TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST 4 3.1 CONDUCTED EMISSION TEST 7 3.2 RADIATED EMISSION TEST 11 3.3 ELECTROSTATIC DISCHARGE IMMUNITY TEST 14

More information

EMC Test report for LED Panel Light Models , , , , ,

EMC Test report for LED Panel Light Models , , , , , 4326247.50 EMC Test report for LED Panel Light Models 000529, 000530, 000531, 000532, 000535, 000536 Guangzhou, date of issue: 2016-02-24 Author:Jazz Liang By order of Marvo Verlichting B.V. at Hoogeveen,

More information

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan EMC TEST REPORT For MPP SOLAR INC Model Number: PIP 2424MS Prepare for Address : MPP Solar Inc : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan Prepare by Address : MPP Solar In : 4F, No. 50-1,

More information

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass Reference No.: WTD15S0730643E Page 2 of 42 1 Test Summary Test Item Conducted Disturbance at Mains Terminal, 9kHz to 30MHz Radiation electromagnetic disturbance, 9kHz to 30MHz Radiation Emission, 30MHz

More information

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758 Page 1 of 20 Report No. R011604553E EMC TEST REPORT for DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., LTD. Electronic calculator Model No.: KF15758 Prepared for Address Prepared by Address : DONGGUAN EVER

More information

For the following Product : LED CONVERTER Model Name : OLW250P701N1A

For the following Product : LED CONVERTER Model Name : OLW250P701N1A EU Declaration of Conformity EU Declaration of Conformity According to EMC Directive 2004/108/EC For the following Product : LED CONVERTER Model Name : OLW250P701N1A Manufactured at : SoluM Co., Ltd. Address

More information

For the following Product : LED CONVERTER Model Name : OLW160P351N1A

For the following Product : LED CONVERTER Model Name : OLW160P351N1A EU Declaration of Conformity EU Declaration of Conformity According to EMC Directive 2004/108/EC For the following Product : LED CONVERTER Model Name : OLW160P351N1A Manufactured at : SoluM Co., Ltd. Address

More information

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result

More information

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,

More information

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result

More information

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC VERIFICATION SUMMARY Report No.: SZHH EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA

More information

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province. DONGGUAN FIT-WATCH CO., LTD. EMC REPORT Prepared For : DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province Product Name : Trade Name : Model

More information

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B Page 1 of 27 Report No. R011412016E-1 EMC TEST REPORT for LEDELS LIGHTING CO., LTD LED module Model No. : LL-F12T4815X6B Prepared for : LEDELS LIGHTING CO., LTD Address : 5F, Block C, Mingjinhai Ind. Park,

More information

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by EMC TEST REPORT For KST DIGITAL TECHNOLOGY LIMITED Coreless Servo Model No.: X12-508 Additional Model No.: DS215MG, DS315MG, DS213MG, DS313MG, DS12C, DS12T, X12-306 Prepared for Address : KST DIGITAL TECHNOLOGY

More information

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25 15072259 001 Seite 2 von 25 Page 2 of 25 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE 4.1.4 DISCONTINUOUS INTERFERENCE

More information

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20 Shenzhen Toby Technology Co., Ltd. Report No.: TB-EMC125641 Page: 1 of 20 EMC Test Report Application No. : TB12114299 Applicant : Newmb Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : USB HUB

More information

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China EMC-Report No.:SZZCT1502030B-EMC-02 EMC Test Report Product Model Number : Drift car : P01 Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

More information

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by

More information

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27 15072768 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE

More information

EMC Test Report. Report Number: M030826

EMC Test Report. Report Number: M030826 Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report

More information

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz Reference No.: WTU15U0933879E Page 2 of 45 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result

More information

TEST REPORT... 1 CONTENT...

TEST REPORT... 1 CONTENT... CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2

More information

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 10

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 10 TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST 4 3.1 CONDUCTED EMISSION TEST 7 3.2 RADIATED EMISSION TEST 10 80, Jeil-ri, Yangji-myun, Cheoin-gu, Yongin-si, Gyeonggi-do,

More information

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD Page 1 of 45 Report No. R011607240E EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD INVERTER CHARGER Model No.: PV35-4K DC24V MPK, PV35-4K DC48V MPK, PV35-5K DC48V MPK, PV35-6K DC48V MPK Prepared

More information

EMC TEST REPORT : EGO-PZ001, EGO-PZ002, EGO-PZ003, EGO-PZ004, EGO-PZ005, EGO-PZ006, EGO-PZ007, EGO-PZ008

EMC TEST REPORT : EGO-PZ001, EGO-PZ002, EGO-PZ003, EGO-PZ004, EGO-PZ005, EGO-PZ006, EGO-PZ007, EGO-PZ008 Report No. : 08.08.16.0259.01 EMC TEST REPORT Applicant : Eastgate Global Holding LTD Address : DongchuanRoad,Baiyun 1Street,No.6 Office 502 Manufacturer : Eastgate Global Holding LTD Address : DongchuanRoad,Baiyun

More information

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8 EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8 Prepared for Address : ShenZhen ZhangQing Electronic LTD :

More information

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45 REPORT NO. PRSZ15110502E EMC TEST REPORT For Boardcon Technology Limited. MINI9G45 Computer on Module Model No. : MINI9G45 Prepared For : Boardcon Technology Limited. : Room 702, Hua Feng Xin An Business

More information

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name: Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator EAST ZTY-30KVA Date of Receipt : Aug. 30, 2013 Date of Test: Sep. 03, 2013

More information

EMC TEST REPORT. Report No.: CE10-LIE040101E

EMC TEST REPORT. Report No.: CE10-LIE040101E EMC TEST REPORT Report No.: CE10-LIE040101E Product: LED TUBE Model No.: T10, T8, T5 Applicant: Shenzhen Saiju Electronic Co., Ltd. Address: 2nd. Xianshun Industrial Park, Gushu, Xixiang, Bao an, Shenzhen,

More information

EMC TEST REPORT CE TEST REPORT. Report Number : ETLE Report issue date: August 21, 2009

EMC TEST REPORT CE TEST REPORT. Report Number : ETLE Report issue date: August 21, 2009 CE TEST REPORT Report Number : ETLE080219.157.1 Report issue date: August 21, 2009 Model / Serial No. : NSD-S360 / NONE Multiple Model Name : NSD-S300, NSD-S230, NSD-S680, NSD-H350, NSD-S330, NSD-S370,

More information

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA Shenzhen BST Technology Co., Ltd. ITUNER NETWORKS CORPORATION EMC REPORT Prepared For : ITUNER NETWORKS CORPORATION 47801 Fremont Blvd. Fremont, CA. 94538 Product Name: PicoPSU-150 Trade Name: PicoPSU

More information

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC. Report No.: UNI2016121702ER-01 Page 1 / 30 ShenZhen KY Technology Co.,Ltd EMC REPORT Prepared For: ShenZhen KY Technology Co.,Ltd Product Name: Smart bracelet No.369, BaoTian 1st RD, TieGang Industrial

More information

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E CE-EMC Test Report Applicant: Product Description: Tested Model: Test Standards: Report No.: United GULF GATE Trd. Co. XonTel MS EN 55032:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024 :2010+A1 :2015

More information

EMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment

EMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment CE TEST REPORT for Audio / Video receivers and associated equipment Report Number : ETLE100104.03 Report Issue Date: January 15, 2010 Model / Serial No. : WSTA-VM300P / NONE Multiple Model Name : WSTA-VM320P,

More information

Test Report GUANGDONG EAST POWER CO., LTD

Test Report GUANGDONG EAST POWER CO., LTD Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA906IIRTS, EA906IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014

More information

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name: APPLICATION FOR EMC DIRECTIVE On Behalf of Shenzhen Qinhan Lighting Co., Ltd led flood light Trade Name: Model: QH-TGC-400W, QH-TGC-300W, QH-TGC-500W, QH-TGC-800W, QH-TGC-1000W Prepared For : Shenzhen

More information

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 The following information was submitted and identified by/on behalf of the client as: Applicant : Ningbo Shanhuang Electric Appliance

More information

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed 17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:

More information

EMC TEST REPORT. For Shenzhen Scotle Technology Ltd CNC ROUTER. Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325

EMC TEST REPORT. For Shenzhen Scotle Technology Ltd CNC ROUTER. Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325 Page 1 of 39 EMC TEST REPORT For Shenzhen Scotle Technology Ltd CNC ROUTER Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325 Test Report Number : ESTBA151101209E SHENZHEN

More information

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

Test Report. Ningbo Goldmore Industrial Co.,Ltd. Test Report Applicant: Ningbo Goldmore Industrial Co.,Ltd. Product Name: Brand Name: Model No.: LED CAMPING LANTERN with FAN N/A XJH-8098 Date of Receipt : Sep. 23, 2014 Date of Test: Sep. 25, 2014 Date

More information

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN AUSTRALIA TEST REPORT For KLM Lighting Co., Limited LED Down Light Model No.: KLM-HP30WSN Additional Model No.: KLM-SM-50-002, KLM-HP7WSS, KLM-HP10WSS, KLM-HP12WSS, KLM-HP15WSS, KLM-HP20WSS, KLM-HP30WSS,

More information

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS Prepared For : Prepared By : Changzhou Airwheel Technology Co.,Ltd. Fl.5, East of No. 10 Building, high-tech

More information

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

Guangdong East Power Co., Ltd. Uninterruptible Power Systems Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Uninterruptible Power Systems EAST EA8806, EA8804 Date of Receipt : Nov. 01, 2012 Date of Test: Nov. 03, 2012

More information

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT ELECTROMAGNETIC COMPLIANCE TEST REPORT For Electric nail art drill Model Name: HBS-021, HBS-278, HBS-288, HBS-530, HBS-540 Brand Name: Date of Issue: May 7, 2011 Prepared For Houbos Hardware & Electrical

More information

The standards relevant for the evaluation of EMC requirements are as follows:

The standards relevant for the evaluation of EMC requirements are as follows: EU Declaration of Conformity EU Declaration of Conformity According to EMC Directive 2004/108/EC For the following Product : LED CONVERTER Model Name : PSDH470102B Variant Model Name : PSDH470102A Applicant

More information

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003 Page: 1 of 20 EMC TEST REPORT Reference No. Applicant : WT05060412 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Cable Standards Model No : UAS111-M, UAS111, UAS112 : EN55022:1998+A2:2003

More information

EMC test report AU01+E04

EMC test report AU01+E04 Customer: Altuflevskoye shosse,h.48,bld.1pr.1,room39 Moscow,127566 Russia EMC test report 130504-AU01+E04 This test report may not be copied or published in a part without the written authorization of

More information

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46 TABLE OF CONTENTS 1. GENERAL INFORMATION...5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)...5 1.2 OBJECTIVE...5 1.3 RELATED SUBMITTAL(S)/GRANT(S)...5 1.4 TEST METHODOLOGY...5 1.5 TEST FACILITY...5

More information

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR Prepared for Address : SHENZHEN EAGLE TECHNOLOGY CO., LTD : A FIoor 1 BIdg.14, Changfeng

More information

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A EMC Test Report Applicant: Address of Applicant: Trade Name: FATEK AUTOMATION CORP. 26FL, NO.29, SEC.2, JUNGJENG E. RD., DANSHUEI DIST., NEW TAIPEI CITY, TAIWAN, R.O.C. FATEK Equipment Under Test: Training

More information

PT. SARANA KARYA SOLUSINDO.

PT. SARANA KARYA SOLUSINDO. Shenzhen BST Technology Co., Ltd. PT. SARANA KARYA SOLUSINDO. EMC REPORT Prepared For : PT. SARANA KARYA SOLUSINDO. Puri Surya Jaya J1. 29 Cluster Vancouver, Gedangan, Sidoarjo, Jawa Timur - Indonesia

More information

ELECTRONICS TESTING CENTER(ETC), TAIWAN

ELECTRONICS TESTING CENTER(ETC), TAIWAN File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 1 / 35 TEST REPORT Responsible Party Manufacturer Description of Product Trade Name : Huan Vu Enterprise Co., Ltd. : Huan Vu Enterprise Co.,

More information

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments EMC Page 3 / 33 Test report No.: EN 61000-6-3:2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Date of measurement: 2013-10-16

More information

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Page 1 of 18 EMC TEST REPORT Report No.: TS08100063-EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Applicant: Test Method/ Standard: Test By: FLUKE CORP. 6920 Seaway Blvd, M/S 266D Everett, WA 98203

More information

1 SUMMARY OF STANDARDS AND RESULTS

1 SUMMARY OF STANDARDS AND RESULTS 1 SUMMARY OF STANDARDS AND RESULTS 1.1 Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below: EMISSION Description of Test Item Standard

More information

EMC TEST REPORT For CE

EMC TEST REPORT For CE EMC TEST REPORT For CE Test Report No. : CTK-2013-01069 Date of Issue : 2013-07-02 Kind of Product : FnIO S-Series Basic Model/Type No. : NA-9211, ST-5725, ST-5726 Variant Model/Type No. : NA-9212 Applicant

More information

EMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U

EMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U EMC TEST REPORT For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U Prepared for Address : PEAK ELECTRONIC(HUIZHOU)CO., LTD. :

More information

Page: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6

Page: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6 Page: 1 of 41 EMC TEST REPORT Reference No. Applicant : WT05060416 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Multi-socket with surge protection Standards Model No. : SPG3-B-10,

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Variant Model Name: Applicant: CAMERA HOUSING SAMSUNG TECHWIN CO., LTD. SCX-FH200B SHB-4200 SAMSUNG TECHWIN

More information

5.3 TEST SETUP AND PROCEDURE TEST DATA MEASUREMENT UNCERTAINTY FLICKER USED TEST EQUIPMENT...18

5.3 TEST SETUP AND PROCEDURE TEST DATA MEASUREMENT UNCERTAINTY FLICKER USED TEST EQUIPMENT...18 CONTENT TEST REPORT...1 CONTENT...2 1 TEST RESULTS SUMMARY...4 2 EMC RESULTS CONCLUSION...5 3 LABORATORY MEASUREMENTS...6 4 EMI TEST...7 4.1 EN 55014-1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST...7

More information

EMC Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. Power supply STR E. Damon Ma / Engineer

EMC Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. Power supply STR E. Damon Ma / Engineer Test Standards: EMC Measurement and Test Report Product Description: Tested Model: Report No.: For 186 Veterans Dr. Northvale, NJ 07647 USA EN 55022:2010 EN 61000-3-2:2006+A1:2009+A2:2009 EN 61000-3-3:2008

More information

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017 EN 301 489-17 v3.1.1 TEST REPORT FOR Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017 Prepared for Texas Instrument 2900 Semiconductor Drive Santa

More information

EMC TEST REPORT For MUST POWER LIMITED. Inverter. Model No.: PV18-5K MPK, PV18-5K PK, PV18-4K MPK, PV18-4K PK

EMC TEST REPORT For MUST POWER LIMITED. Inverter. Model No.: PV18-5K MPK, PV18-5K PK, PV18-4K MPK, PV18-4K PK EMC TEST REPORT For MUST POWER LIMITED Inverter Model No.: PV18-5K MPK, PV18-5K PK, PV18-4K MPK, PV18-4K PK Prepared for : MUST POWER LIMITED Address : 4-5F Bldg11, Yusheng Industrial Park,No 467, Xixiang,

More information

2620 Modular Measurement and Control System

2620 Modular Measurement and Control System European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic

More information

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) EMC TEST REPORT For Company Limited Liability «Faraday Electronics» Switching Mode Power Adaptor Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) Prepared For : Company Limited Liability «Faraday

More information

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi EMC TEST REPORT For Shenzhen Ruideou Keji Youxian Gongsi Product Name: Trademark: Milligram Scale WAOAW Model Number: W-01-50 Prepared For : Address: Prepared By : Address: Shenzhen Ruideou Keji Youxian

More information

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U Prepared for Address : GZTOD.CO., LTD : 2-5/F, Building A4, Huimingsheng Industrial Park, Tongfuyu

More information

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-89486194-805 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances,

More information

Test Report GUANGDONG EAST POWER CO., LTD

Test Report GUANGDONG EAST POWER CO., LTD Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA902IIRTS, EA902IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014

More information

The standards relevant for the evaluation of EMC requirements are as follows:

The standards relevant for the evaluation of EMC requirements are as follows: EU Declaration of Conformity EU Declaration of Conformity According to EMC Directive 2004/108/EC For the following Product : LED CONVERTER Model Name : PSDH400701A Variant Model Name : PSDH400701B Applicant

More information

EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20

EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20 EMC TEST REPORT For Soma Medical (Sabah) Sdn Bhd (1248058-D) UVGI AIR STERILIZER Model No.: SM 20 Prepared For : Soma Medical (Sabah) Sdn Bhd (1248058-D) : Block E, Lot 28, 2nd floor, Signature Office,

More information

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10 CE/EMC TEST REPORT For HK QNOVATOR TECHNOLOGY CO.,LIMITED Product Name: Vacuum Tube Amplifier Trademark: Model Number: Prepared For: Address: Gemtune GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05,

More information

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China 4317137.50 EMC Test report for LED Fixed luminaires Models LED12036-1R, LED12036-2TU, LED120363R, LED12036-4TU2, LED12036-6TR, LED12036-1R CHR, LED12036-2TU CHR, LED12036-3R CHR, LED12036-4TU2 CHR, LED12036-6TR

More information

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED ITaste vv Model No.: ITaste vv Prepared for : INNOKIN TECHNOLOGY CO., LIMITED Address : 3# Floor, #B Building, Heng Chang Rong Industrial Park, Gonghe

More information

Page: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK

Page: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK Page: 1 of 46 Reference No. Applicant : WT05060414 EMC TEST REPORT : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Advanced surge protection Model No. : SISF, SISF-2, SISFN-BLACK,

More information

EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58

EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58 EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58 Prepared for : TEA-Energy China Limited Address : 0100029 Building,

More information

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CGZ3150428-00472-E-R1 2/F., South Tower, Huoju Building, No.181, Canghai Road,

More information

TEST REPORT on behalf of Shanghai ZLAN Information Technology Co.,Ltd Serial Device Server

TEST REPORT on behalf of Shanghai ZLAN Information Technology Co.,Ltd Serial Device Server TEST REPORT on behalf of Shanghai ZLAN Information Technology Co.,Ltd Serial Device Server Prepared For: Shanghai ZLAN Information Technology Co.,Ltd. Room 1205, Building D Everbright Exhibition Center,

More information

The standards relevant for the evaluation of EMC requirements are as follows:

The standards relevant for the evaluation of EMC requirements are as follows: EU Declaration of Conformity EU Declaration of Conformity According to EMC Directive 2004/108/EC For the following Product : LED CONVERTER Model Name : PSDV600102A Applicant : SAMSUNG ELECTRO-MECHANICS

More information

EMC TEST REPORT For. Global Tech China Limited. 120/200 Watt Mightylite. Model No.: Additional Model No: Please Refer To Page 57

EMC TEST REPORT For. Global Tech China Limited. 120/200 Watt Mightylite. Model No.: Additional Model No: Please Refer To Page 57 EMC TEST REPORT For Global Tech China Limited 120/200 Watt Mightylite Model No.: 0022031 Additional Model No: Please Refer To Page 57 Prepared for Address : Global Tech China Limited : 3 Flat A, Wai Yip

More information

Revision History of Report

Revision History of Report Revision History of Report Rev. Revisions Effect page Reviewed by Date - Initial issue All J. S. Yoon March 7, 2014 A1 Administrative change P1 and P5 J. S. Yoon March 20, 2015 (Revision A1) This amendment

More information

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed

More information

FCC Verification TEST REPORT

FCC Verification TEST REPORT FCC Verification TEST REPORT Product: 5 in 1 Environment Meter Model no.: ET-965 Trade Mark: N/A Report No.: TCT140915E005 Issued Date: Sep. 22, 2014 Issued for: Shenzhen Flus Technology Co., Ltd 3rd Floor,

More information

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

Contents. Report No.: EMC-CE-2114 Page: 2 of 39 Page: 2 of 39 Contents 1. Applicant information... 3 2. Laboratory information... 4 3. Test system configuration... 5 3.1 Operation environment... 5 3.2 Measurement Uncertainty... 6 4. Description of E.U.T...

More information

EMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S

EMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S EMC TEST REPORT For Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope Model No.: MS520S Additional Model No: Please Refer To Page 47 Prepared for Address : Shenzhen Micsig Instruments

More information

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-26636041 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances, electric tools

More information

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42. EMC TEST REPORT For Shenzhen Smar TEC Technology Company Smart Charger For Li-Ion&Lifepo4 Battery Pack Model No.:SPS-F12S02-021(42.6V/2A) Prepared for : Shenzhen Smar TEC Technology Company Address : 4-5/F.,

More information

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd Page 1 of 15 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EN61326 EMC COMPLIANCE

More information

EMC TEST REPORT For Gztod. Co., Ltd. Smart USB Charger Model No.: YA50WS3-8U

EMC TEST REPORT For Gztod. Co., Ltd. Smart USB Charger Model No.: YA50WS3-8U EMC TEST REPORT For Gztod. Co., Ltd. Smart USB Charger Model No.: YA50WS3-8U Prepared for : Gztod. Co., Ltd. Address : 2-5/F, Building A4, Huimingsheng Industrial Park, Tongfuyu Dingfeng High-Tech District,

More information

EMC TEST REPORT For LOKOLED LED Downlight Model No.: LL-17-45W-Floodlight-R-VL, LL-06-45W-18K/M

EMC TEST REPORT For LOKOLED LED Downlight Model No.: LL-17-45W-Floodlight-R-VL, LL-06-45W-18K/M EMC TEST REPORT For LOKOLED LED Downlight Model No.: LL-17-45W-Floodlight-R-VL, LL-06-45W-18K/M Prepared for Address : LOKOLED : Kitmanstraat 14 1812 PM Alkmaar The Netherlands Prepared by : Shenzhen LCS

More information

CE TEST CERTIFICATION

CE TEST CERTIFICATION according to Certification No.: E5NC004 European Standard EN 61000-6-4:2001 EN 61000-3-2: 2000, EN 61000-3-3:1995/A1:2001 and EN 61000-6-2:2001 ( IEC 61000-4-2:1995/A1:1998, IEC 61000-4-3: 1995/A1:1998,

More information

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan Page 1 of 32 EMC TEST REPORT Report No.: TS11020117-EME Model No.: NS-PSE, NS-POINTED, NS-PSQUARE, NS-PF-S, NS-PT, NS-PR, NS-PU, NS-PF-H, NS-BALIBA, NS-FLEXMA Issued Date: Mar. 01, 2011 Applicant: NORTE

More information

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release REVISION HISTORY The revision history for this document is shown in table. Version Issue Date Description HCT-EM-1801-FC037 January 22, 2018 Initial Release HCT-EM-1801-FC037-R1 January 26, 2018 Revision

More information

EMC Test Report. Shenzhen JT Detection Technology Co., Ltd. Product : Car LED headlight bulbs Brand Name :WEIYAO AUTO LED.

EMC Test Report. Shenzhen JT Detection Technology Co., Ltd. Product : Car LED headlight bulbs Brand Name :WEIYAO AUTO LED. EMC Test Report Product : Car LED headlight bulbs Brand Name :WEIYAO AUTO LED Model Number : V8 series,h1,h3,h4,h7,h11,h13,h16,9005,9004,9006,9007, 880,881,D2,PX26 Prepared for : Guangzhou WEIYAO auto

More information

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23 D I R E C T O R Y A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23 B) Test data: Immunity against Electrostatic discharge

More information

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE EMC TEST REPORT For SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD Product Name: Pure sine wave power inverter Trademark: Model : Prepared For : Address: Prepared By : Address: ML-1000W ML-300W---ML-8000W.

More information

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd. EMC Testing Report Equipment Under Test: Model Number: Serial No.: Applicant: Address of Applicant: Multi-Frequency (4 Channel Selectable) Twin Photobeam Detector Dual-120CS Dual-90CS, Dual-60CS, Dual-30CS

More information