EMC TEST REPORT CE TEST REPORT. Report Number : ETLE Report issue date: August 21, 2009

Size: px
Start display at page:

Download "EMC TEST REPORT CE TEST REPORT. Report Number : ETLE Report issue date: August 21, 2009"

Transcription

1 CE TEST REPORT Report Number : ETLE Report issue date: August 21, 2009 Model / Serial No. : NSD-S360 / NONE Multiple Model Name : NSD-S300, NSD-S230, NSD-S680, NSD-H350, NSD-S330, NSD-S370, NSD-S230IP, NSD-S300IP, NSD-S330IP, NSD-S360IP, NSD-S370IP, NSD-S680IP Product Type : INTELLIGENT DOME CAMERA Applicant : NEW BORN HIGHTECH Address : Byucksan/Kyungin Digital Valley ~1220, Gasan-dong, Geumcheon-gu, Seoul, Korea Manufacturer : NEW BORN HIGHTECH Address : Byucksan/Kyungin Digital Valley ~1220, Gasan-dong, Geumcheon-gu, Seoul, Korea Test Standard(s) : EN 55022: A1: A2: 2003 (Class A) EN : A1: A2: 2003 Test Result : Positive Total pages including Attachments : 41 Prepared by: Hyung-min, Choi (Test Engineer) Reviewed by: Yo Han, Park (Chief Engineer) August 21, 2009 August 21, 2009 ETL Inc , Gasan-dong, Geumcheon-gu, Seoul, , Korea Tel : Fax : The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report no. ETLE / Page 1 of 26

2 DIRECTORY A) Documentation Directory 2 Test Standards 3 Address of the test laboratory, Conditions/Power Utilized, Description of the EUT & Symbol Definitions 4 Equipment under Test 17 Summary 18 Test Setups (Photographs) B) Test Data Conducted Emissions 150 khz - 30 MHz 5 Radiated emissions (electric field) 30 MHz MHz 6 Harmonic Current Emissions and Flicker 7 Electrostatic Discharge (ESD) 8 11 Radiated Electromagnetic Fields 12 EFT / Burst 13 Surge Transients 14 Conducted Disturbance 15 Voltage Dips, Interruptions & Variations 16 C) Attachment A. Test Data and Test Setup Drawing(s) A1 A6 B. List of Test Equipments B1 B3 C. Photo documentations C1 C4 D. Technical description of the test sample (e.g.cdf, Declaration) D1 D2 Report no. ETLE / Page 2 of 26

3 EMC TEST STANDARD(S) The emc tests were performed according to the following standards: EMC - Directive 2004/108/EC and its amendments EN 55022: A1: A2: Class A - Class B EN : A1: A2: 2003 EN : A2: 2005 EN : A1: A2: 2005 IEC : A1: A2:2000 IEC : A1:2002 IEC : 2004 IEC : A1:2000 IEC : A1:2000 IEC : A1:2000 IEC : 2004 Note: For undated references, the latest edition of the publication at the time of testing (including amendments) was applied. Report no. ETLE / Page 3 of 26

4 ADDRESS OF THE TEST LABORATORY ETL Inc. (Seoul office and EMC Laboratory) # Gasan-dong, Geumcheon-gu, Seoul, , Korea ETL Inc. (Yoju EMC Laboratory) #584, Sangwhal-ri, Ganam-myeon, Yoju-gun, Gyeonggi-do, , Korea ENVIRONMENTAL CONDITIONS During the measurement the environmental conditions were within the listed ranges: Temperature : 15 C - 35 C Humidity : 30 %R.H %R.H. Atmospheric Pressure : 86 kpa kpa POWER SUPPLY SYSTEM UTILIZED Power supply system DC 24 V or AC 24 V SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT) Number of received / tested samples: 1 / 1 Serial Number: none DEFINITIONS FOR SYMBOLS USED IN THIS TEST REPORT The black square indicates that the listed condition, standard or equipment is applicable for this report. Blank box indicates that the listed condition, standard or equipment was not applicable for this report. Report no. ETLE / Page 4 of 26

5 Conducted Emission (Interference Voltage) Test Conducted emissions were measured from 150 khz to 30 MHz with a bandwidth of 9 khz on the 230 V AC power and return leads of the EUT according to the methods defined in EN The EUT was placed upon a non-metallic table 0,8 m above the horizontal metal reference plane and placed 0,4 m from a vertical ground plane which is connected to the horizontal metal ground plane. Test not applicable Test area - shielded room Anechoic chamber Full compact chamber Used test instruments and test accessories please see Attachment B. Equipment type Class A Class B Frequency Range (MHz) Quasi-Peak limit (dbuv) Average limit (dbuv) 0,15 to 0, ,5 to ,15 to 0,5 66 to to 46 0,5 to to Pass Fail Minimum limit margin 22,80 db at 0,600 MHz Maximum limit exceeding db at MHz Remarks: Please refer to the test data and graph in Attachment A. Test is AC 24 V rated input voltages mode. (DC 24 V rated input voltages mode was not applied.) Report no. ETLE / Page 5 of 26

6 Radiated Emission (electric field) Test Radiated emissions form 30 MHz to MHz were measured with a bandwidth of 120 khz according to the methods defines in EN The EUT was placed on a non-metallic stand in the open-field site, 0,8 m above the ground plane. The interface cables and equipment positions were varied within limits of reasonable applications to determine the positions producing maximum radiated emissions. Test not applicable Test area - open site. Testing was performed at a test distance of: 10 m Used test instruments and test accessories please see Attachment B. Equipment type Class A Class B Frequency Range (MHz) Quasi-Peak limit (dbuv/m) 30 to to to to Pass Fail Minimum limit margin 5,70 db at 141,81 MHz Maximum limit exceeding db at MHz Remarks: Please refer to the test data in Attachment A. Test is DC 24 V and AC 24 V rated input voltages mode. Report no. ETLE / Page 6 of 26

7 Harmonic Current Emissions and Flicker Power Frequency Harmonics Tests: The measured values of the harmonics components of the input current, including line current and neutral current, shall be compared with the limits given in EN Flicker Emission Tests: The total impedance of the test circuit, excluding the appliance under test, but including the internal impedance of the supply source, shall be equal to the reference impedance. Test not applicable Test area - ETL Harmonics test room Anechoic chamber Full compact chamber Used test instruments and test accessories please see Attachment B. Pass Fail Remarks: This test was not applied. Because, EUT power supplies from a DC 24 V or AC 24 V.. Report no. ETLE / Page 7 of 26

8 Electrostatic Discharge (ESD) Immunity Test Tests were conducted in accordance with EN The test programs and software shall be chosen so as to exercise all normal modes of operation of the EUT. The use of special exercising software is encouraged, but permitted only where it can be shown that the EUT is being comprehensively exercised. Test not applicable ETL test room Used test instruments and test accessories please see Attachment B. Test specifications: Discharge Voltage (Air): 2,0 kv 4,0 kv 6,0 kv 8,0 kv Discharge Voltage (Contact): 2,0 kv 4,0 kv 6,0 kv Discharge Impedance: 330 Ω / 150 pf Discharge Repetition Rate: 1 s Number of Discharges: 10 at all locations Kind of Discharges: Air discharge Contact discharge Polarity: Positive Negative Location of Discharge: See Photograph (ESD Point map) Each location on the surface touchable by hand HCP, VCP Required performance criterion: Test results: There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of the discharges is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change. Met required performance criterion Report no. ETLE / Page 8 of 26

9 Test data Test Point Discharge Type Discharge voltage [± kv] HCP / VCP Indirect 2 / 4 / 6 1. Screw point Contact 2 / 4 / 6 2. Video Out port Contact 2 / 4 / 6 3. Metal case Contact 2 / 4 / 6 Result Met required performance criterion Met required performance criterion (See the remarks) Remarks: During the contact discharge test, dot noise was appeared on screen of LCD TV Monitor. After the test, EUT was operated normally. Please refer to the test point in next page. Report no. ETLE / Page 9 of 26

10 CONTACT AIR Report no. ETLE / Page 10 of 26

11 CONTACT AIR Report no. ETLE / Page 11 of 26

12 Radiated Electromagnetic Fields Immunity Test Tests were conducted in accordance with EN over the frequency range of 80 MHz to MHz. The transmitting antenna was located 3 m from the EUT at a height of 0,8 m above the floor. Front, sides and back of the EUT were exposed to a uniform field of 10 V/m using both horizontal and vertical antenna polarizations. Test not applicable ETL Semi-Anechoic chamber Full compact chamber Used test instruments and test accessories please see Attachment B. Test specifications: Frequency Range: 80 MHz MHz Field Strength: 1 V/m 3 V/m 10 V/m Distance Antenna - EUT: 3 m Modulation: AM 1 khz 80 % Step/Dwell Time: 1 % / 3 s Polarization of Antenna: Horizontal Vertical Position of EUT Required performance criterion: Test result: There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the conditioning is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change, and no such flickering of indicators occurs at a field strength of 3 V/m. - 1 V/m : no observable deterioration - 3 V/m : any deterioration of the picture is so minor that the system could still be used V/m : no permanent damage or change Met required performance criterion Test data Frequency Range (MHz) Field Strength (V/m) Antenna Polarity Position (Angle) Result & 3 Vertical Front / Rear / Right / Left & 3 Horizontal Front / Rear / Right / Left Vertical Front / Rear / Right / Left Horizontal Front / Rear / Right / Left Met required performance criterion Met required performance criterion (See the remarks) Remarks: During the Radiated Electromagnetic Fields test to 10 V/m, line noise was appeared on screen of LCD TV Monitor. After the test, EUT was operated normally. Report no. ETLE / Page 12 of 26

13 EFT/Burst Immunity Test Tests were conducted in accordance with EN Test not applicable ETL test room Used test instruments and test accessories please see Attachment B. Test specifications: Pulse Amplitude - AC Power Port: 2,0 kv Pulse Amplitude - DC Power Port: 1,0 kv Signal Port: 1,0 kv Burst Frequency: 5,0 khz Time of Coupling: 60 s Polarity: Positive Negative Location of Coupling Name of lines Type Length Remarks AC Power line 2-pins 0,5 m DC power line Unshielded >3,0 m Video Out Shielded >3,0 m Signal line RS-485/422 / AUX / SENSOR Unshielded >3,0 m Signal line Required performance criterion: Test result: There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of the bursts is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change. Met required performance criterion Test data Line Line for test Test level Coupling (± kv) Method AC-mains L/N 2 CDN AC-mains L+N 2 CDN DC-mains +, 1 Clamp Signal line Video Out 1 Clamp Signal line RS-485/422 / AUX / SENSOR 1 Clamp Result Met required performance criterion (See the remarks) Remarks: During the test, dot noise was appeared on screen of LCD TV Monitor. After the test, EUT was operated normally. Report no. ETLE / Page 13 of 26

14 Surge Immunity Test Tests were conducted in accordance with EN Test not applicable ETL test room Used test instruments and test accessories please see Attachment B. Test specifications: Pulse Amplitude - AC Power Port: 0,5 kv 1,0 kv Pulse Amplitude - DC Power Port: Signal Port: 0,5 kv 0,5 kv Source Impedance: 2 Ω + 18 µf 12 Ω + 9 µf 42 Ω + 0,1 µf Number of Surges: 5 surges/angle Angle: Repetition Rate: 60 s Polarity: Positive Negative Location of Coupling Name of lines Type Length Remarks AC Power line 2-pins 0,5 m Required performance criterion: Test result: There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the application of the surges is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change. Met required performance criterion Test data Line Line for test Test level (± kv) Coupling Method AC-mains L+N 0,5 / 1,0 CDN Result Met required performance criterion Remarks: No false or other malfunctions were observed during and after the test. Report no. ETLE / Page 14 of 26

15 Conducted Disturbance Immunity Test Tests were conducted in accordance with EN over the frequency range of 150 khz to 100 MHz. Test not applicable ETL test room Used test instruments and test accessories please see Attachment B. Test specifications: Frequency Range: 0,15 MHz 100 MHz Voltage Level (EMF): 1 V 3 V 10 V Modulation: AM 1 khz 80 % PM 1 Hz Step/Dwell Time: 1 %/3 s Location of Coupling Name of lines Type Length Remarks AC Power line 2-pins 0,3 m DC power line Unshielded 0,3 m Video Out Shielded >3,0 m Signal line RS-485/422 / AUX / SENSOR Unshielded >3,0 m Signal line Required performance criterion: Test result: There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the conditioning is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change, and no such flickering of indicators occurs at a field strength of 3 V. - 1 V : no observable deterioration - 3 V : any deterioration of the picture is so minor that the system could still be used V : no permanent damage or change Met required performance criterion Test data Frequency Range Test level Coupling Line for test (MHz) (V) Method 0, AC-mains 1 & 3 CDN 0, DC-mains 1 & 3 CDN 0, Signal line 1 & 3 Clamp 0, AC-mains 10 CDN 0, DC-mains 10 CDN 0, Signal line 10 Clamp Result Met required performance criterion Met required performance criterion (See the remarks) Remarks: During the Conducted Disturbance test to 10 V, line noise was appeared on screen of LCD TV Monitor. After the test, EUT was operated normally. Report no. ETLE / Page 15 of 26

16 Voltage Dips, Interruptions & Variations Immunity Test Voltage variations tests were conducted in accordance with EN Test not applicable ETL test room Used test instruments and test accessories please see Attachment B. Test specifications: Nominal Mains Voltage (V NOM ): Level of Reduction (dip): 24 Vac 0,5 Period, 1 Period, 5 Period, 10 Period at 30 % of V NOM 0,5 Period, 1 Period, 5 Period, 10 Period at 60 % of V NOM 0,5 Period, 1 Period, 5 Period at 100 % of V NOM Duration of Interruption: 250 Period at >95 % of V NOM Voltage Fluctuation: Unom + 10 % Unom - 15 % Required performance criterion: Test result: Voltage variations - There shall be no damage, malfunction or change of status due to the different supply voltage conditions. Voltage dips : There shall be no damage, malfunction or change of status due to the conditioning. Flickering of an indicator during the conditioning is permissible, providing that there is no residual change in the EUT or any change in outputs, which could be interpreted by associated equipment as a change. Met required performance criterion Test data Test Test Level (% of V NOM ) Period Voltage dips 30 0,5 / 1 / 5 / 10 Voltage dips 60 0,5 / 1 / 5 / 10 Voltage dips 100 0,5 / 1 / 5 Result Met required performance criterion Test Test level Test voltage Result Voltage variations Supply voltage max. (Unom + 10 %) 26,4 V Voltage variations Supply voltage min. (Unom - 15 %) 20,4 V Met required performance criterion Remarks: No false or other malfunctions were observed during and after the test. Report no. ETLE / Page 16 of 26

17 Equipment Under Test (EUT) Test Operation Mode: The equipment under test was operated under the following conditions during testing: Camera image display mode Camera image display mode and lens angle point auto mode (The worst condition) Configuration of the equipment under test: See constructional data form in Attachment D - Page D2 See product information form(s) in Attachment D - Page D3 The following devices and interface cables were connected during the testing: Type Model Serial No. Manufacturer LCD TV Monitor OR940S NONE ORION Adapter (for LCD TV Monitor) DA-48M12 Y DC power supply E3616A KR HP Type of Cables Used - Power Supply Type: DC 24 V Asian Power Devices Inc. Device from Device to Type of Cable(Port) Length(m) Type of shield EUT LCD TV Monitor Video Out >3,0 Shielded EUT Termination RS-485/422 >3,0 Unshielded EUT Termination AUX >3,0 Unshielded EUT Termination SENSOR >3,0 Unshielded EUT DC power supply AC/DC Input 1,0 Unshielded LCD TV Monitor Adapter DC Input 1,2 Shielded - Power Supply Type: AC 24 V Device from Device to Type of Cable(Port) Length(m) Type of shield EUT LCD TV Monitor VIDEO OUT >3,0 Shielded EUT Termination RS-485/422 >3,0 Unshielded EUT Termination AUX >3,0 Unshielded EUT Termination SENSOR >3,0 Unshielded EUT Power socket AC/DC Input 1,0 Unshielded LCD TV Monitor Adapter DC Input 1,2 Shielded Report no. ETLE / Page 17 of 26

18 GENERAL REMARKS: The Equipment Under Test (EUT) is the NEW BORN HIGHTECH (model: NSD-S360) The model NSD-S360 is basic model that was tested. Model Fitted variety zoom module Effective Pixels No. NSD-S360 (Basic model) x36 410k NSD-S300 x30 410k NSD-S230 x23 410k NSD-S680 x26 680k NSD-H350 x35 410k NSD-S330 x33 410k NSD-S370 x37 410k NSD-S230IP x23 410k NSD-S300IP x30 410k NSD-S330IP x33 410k NSD-S360IP x36 410k NSD-S370IP x37 410k NSD-S680IP x26 680k SUMMARY: All tests according to the regulations cited on page 3 were Performed Not Performed The Equipment Under Test - Fulfills the general approval requirements cited on page 3. - Does not fulfill the general approval requirements cited on page 3. Date of receipt of test sample: February 19, 2008 Test start date: February 20, 2008 Test end date: March 04, 2008 Report no. ETLE / Page 18 of 26

19 Photograph of test setup: Conducted emissions 150 khz - 30 MHz Report no. ETLE / Page 19 of 26

20 Photograph of test setup: Radiated emissions 30 MHz MHz Report no. ETLE / Page 20 of 26

21 Photograph of test setup: Electrostatic discharge (ESD) Report no. ETLE / Page 21 of 26

22 Photograph of test setup: Radiated electromagnetic field Report no. ETLE / Page 22 of 26

23 Photograph of test setup: EFT/Burst - AC power line - - DC power line/signal line - Report no. ETLE / Page 23 of 26

24 Photograph of test setup: Surge Report no. ETLE / Page 24 of 26

25 Photograph of test setup: Conducted disturbance - Power line - - Signal line - Report no. ETLE / Page 25 of 26

26 Photograph of test setup: Voltage dips, interruptions Report no. ETLE / Page 26 of 26

27 Attachment A Test Data and Test Setup Drawing(s) Report no. ETLE / Page A1 of A6

28 Conducted Emissions Measurement EUT Limit apply to INTELLIGENT DOME CAMERA / NSD-S360 (S/N: N/A) EN Class A Test Date February 29, 2008 Power Supply Type Operating Condition Result AC 24 V Camera image display mode and lens angle point auto mode Passed by 22,80 db Conducted Emission Test Data The following table shows the highest levels of conducted emissions on both polarizations of hot and neutral line. Detector mode: CISPR Quasi-Peak mode (6 db Bandwidth: 9 khz) Frequency [MHz] Quasi-peak Result [db μv ] Average Phase (*H/**N) Limit [db μv ] Margin [db] Quasi-peak Average Quasi-peak Average 0,270 52,1 29,4 H 79,0 66,0 26,9 36,7 0,375 54,4 40,9 H 79,0 66,0 24,6 25,1 0,600 50,2 28,8 H 73,0 60,0 22,8 31,2 3,295 43,3 28,2 H 73,0 60,0 29,7 31,8 4,435 42,1 32,6 H 73,0 60,0 30,9 27,4 19,500 43,9 19,2 N 73,0 60,0 29,1 40,8 NOTES: 1. * H : HOT Line, **N : Neutral Line 2. Margin value = Limit Result 3. All conditions were investigated and the worst-case emissions are reported. 4. If the average limit is met when using a Quasi-peak detector receiver, the EUT shall be deemed to meet both limits and measurement with the average detector receiver is unnecessary. Hyung-min, Choi Test Engineer Report no. ETLE / Page A2 of A6

29 Line Polarity : Hot Limit : Quasi-Peak Average Line Polarity : Neutral Quasi-peak Average Report no. ETLE / Page A3 of A6

30 Radiated Emissions Measurement EUT Limit apply to INTELLIGENT DOME CAMERA / NSD-S360 (S/N: N/A) EN Class A Test Date February 29, 2008 Power Supply Type Operating Condition Result DC 24 V Camera image display mode and lens angle point auto mode Passed by 5,70 db Radiated Emission Test Data The following table shows the highest levels of radiated emissions on both polarizations of horizontal and vertical. Detector mode: CISPR Quasi-Peak mode (6 db Bandwidth: 120 khz) Frequency [MHz] Reading [db μv ] Polarization (*H/**V) Ant. Factor [db/m] Cable Loss [db] Result [db μv /m] Limit [db μv /m] Margin [db] 47,72 19,51 V 9,63 2,05 31,20 40,00 8,80 49,77 16,03 V 9,68 2,10 27,80 40,00 12,20 113,82 17,43 V 10,10 2,98 30,50 40,00 9,50 127,49 15,99 V 10,80 3,21 30,00 40,00 10,00 141,81 19,51 V 11,36 3,43 34,30 40,00 5,70 170,44 17,12 V 10,68 3,80 31,60 40,00 8,40 NOTES: 1. * H : Horizontal polarization, ** V : Vertical polarization 2. Result Level = Reading + Antenna factor + Cable loss 3. Margin value = Limit - Result 4. The measurement was performed for the frequency range 30 MHz ~ MHz according to the EN Class A. Hyung-min, Choi Test Engineer Report no. ETLE / Page A4 of A6

31 EUT Limit apply to INTELLIGENT DOME CAMERA / NSD-S360 (S/N: N/A) EN Class A Test Date February 29, 2008 Power Supply Type Operating Condition Result AC 24 V Camera image display mode and lens angle point auto mode Passed by 6,30 db Radiated Emission Test Data The following table shows the highest levels of radiated emissions on both polarizations of horizontal and vertical. Detector mode: CISPR Quasi-Peak mode (6 db Bandwidth: 120 khz) Frequency [MHz] Reading [db μv ] Polarization (*H/**V) Ant. Factor [db/m] Cable Loss [db] Result [db μv /m] Limit [db μv /m] Margin [db] 47,72 11,91 V 9,63 2,05 23,60 40,00 16,40 113,82 17,13 V 10,10 2,98 30,20 40,00 9,80 123,38 18,34 V 10,61 3,15 32,10 40,00 7,90 125,44 17,31 V 10,70 3,18 31,20 40,00 8,80 141,80 18,91 V 11,36 3,43 33,70 40,00 6,30 198,39 16,56 V 9,85 3,99 30,40 40,00 9,60 NOTES: 1. * H : Horizontal polarization, ** V : Vertical polarization 2. Result Level = Reading + Antenna factor + Cable loss 3. Margin value = Limit - Result 4. The measurement was performed for the frequency range 30 MHz ~ MHz according to the EN Class A. Hyung-min, Choi Test Engineer Report no. ETLE / Page A5 of A6

32 The setup drawing(s) - Power Supply Type: DC 24 V DC power supply LCD TV Monitor EUT - Power Supply Type: AC 24 V LCD TV Monitor EUT : Data Line : Power Line : Termination : Adapter Report no. ETLE / Page A6 of A6

33 Attachment B List of Test Equipment Report no. ETLE / Page B1 of B3

34 Emission Test Equipments Description Model Number Manufacturer Serial Number Cal Due Date EMI TEST Receiver ESVS 10 R & S / EMI TEST Receiver ESHS 30 R & S / LISN EMCO LISN EMCO LogBicon Antenna VULB9165 Schwarzbeck Turn-Table DETT-03 Daeil EMC - N/A Antenna Master DEAM-03 Daeil EMC - N/A Report no. ETLE / Page B2 of B3

35 Immunity Test Equipments Description Model Number Manufacturer Serial Number Cal Due Date ESD Generator dito EM TEST AG Hybridlog Antenna HLP-2603 EMC Automation N/A Signal Generator 2025 IFR / Amplifier AR75A250 Amplifier Research N/A RF Amplifier GRF5066 OPHIR 1011 N/A System Interface SI-300 EMC Automation N/A Power Meter 4232A Boonton Power Sensors Boonton / Dual Directional Coupler C5571 Werlatone 7860 N/A Dual Directional Coupler C3653 Werlatone 7825 N/A Switch Module RSM-02 EMC Automation N/A EMC Generator EMC Pro KeyTek Capacitor Clamp N/A KeyTek CDN FCC-801-M2-25A FCC Attenuator Weinschel BH EM Injection Clamp FCC mm FCC POWER AMPLIFIER 60S1G3M3 Amplifier Research N/A Microwave Horn Antenna AT4002A Amplifier Research N/A 40 db COUPLING DC7144A Amplifier Research Report no. ETLE / Page B3 of B3

36 Attachment C Constructional Photographs of Equipment Under Test (EUT) Report no. ETLE / Page C1 of C4

37 View of front View of rear Report no. ETLE / Page C2 of C4

38 View of Bottom Report no. ETLE / Page C3 of C4

39 Inside View of EUT Report no. ETLE / Page C4 of C4

40 Attachment D Constructional Data Form and Product Information Form(s) Report no. ETLE / Page D1 of D2

41 CONSTRTUCTION DATAFORM FOR EMC TESTING Applicant Address : NEW BORN HIGHTECH : Byucksan/Kyungin Digital Valley ~1220, Gasan-dong, Geumcheon-gu, Seoul, Korea Factory Address : NEW BORN HIGHTECH : Byucksan/Kyungin Digital Valley ~1220, Gasan-dong, Geumcheon-gu, Seoul, Korea Type : INTELLIGENT DOME CAMERA Rated voltage : DC 24 V or AC 24 V Serial No. : NONE Rated input power : Protection type : Protection class : Configuration of equipment: Rev. : Rev. : Source of interference : X-TAL 18,432 MHz; 17, MHz; 14,31818 MHz Internal frequency : Noise suppression components : Measures for electromagnetic shielding : Place of issue date Seal and signature of applicant If applicable, if necessary complete overleaf End of test report Report no. ETLE / Page D2 of D2

EMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment

EMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment CE TEST REPORT for Audio / Video receivers and associated equipment Report Number : ETLE100104.03 Report Issue Date: January 15, 2010 Model / Serial No. : WSTA-VM300P / NONE Multiple Model Name : WSTA-VM320P,

More information

TEST REPORT TEST REPORT. Report Number : ETLE Report issue date: May 26, Address : , Gongreung-dong, Nowon-gu, Seoul, Korea

TEST REPORT TEST REPORT. Report Number : ETLE Report issue date: May 26, Address : , Gongreung-dong, Nowon-gu, Seoul, Korea Report Number : ETLE090324.04 Report issue date: May 26, 2009 Model / Serial No. : JULIET-1 / NONE Multiple Model Name : JULIET-2, JULIET-3, ROMEO-1, ROMEO-2, ROMEO-3 Product Type : Hot & Cold Water Purifier

More information

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass Reference No.: WTD15S0730643E Page 2 of 42 1 Test Summary Test Item Conducted Disturbance at Mains Terminal, 9kHz to 30MHz Radiation electromagnetic disturbance, 9kHz to 30MHz Radiation Emission, 30MHz

More information

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,

More information

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result

More information

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12 TABLE OF CONTENTS 1. General Description of EUT 3 2. General Information of Test 4-6 3.1 Conducted Emission Tests 7-12 3.2 Radiated Emission Tests 13-15 3.3 Radiated Electromagnetic disturbance Test 16-20

More information

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10 TABLE OF CONTENTS 1. General Description of EUT 3 2. General Information of Test 4-6 3.1 Conducted Emission Tests 7-10 3.2 Radiated Emission Tests 11-13 3.3 Radiated Electromagnetic disturbance Test 14-18

More information

FCC TEST REPORT. Table of Contents. Report no. ETLE , Page 2 of 21

FCC TEST REPORT. Table of Contents. Report no. ETLE , Page 2 of 21 Table of Contents FCC Measurement Report 1. Introduction 2. Product Information 3. Description of Tests 4. Test Condition 5. Test Results 5.1 Summary of Test Results 5.2 Conducted Emissions Measurement

More information

TEST REPORT... 1 CONTENT...

TEST REPORT... 1 CONTENT... CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2

More information

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

Contents. Report No.: EMC-CE-2114 Page: 2 of 39 Page: 2 of 39 Contents 1. Applicant information... 3 2. Laboratory information... 4 3. Test system configuration... 5 3.1 Operation environment... 5 3.2 Measurement Uncertainty... 6 4. Description of E.U.T...

More information

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result

More information

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007 Certificate of Test WE HEREBY CERTIFY THAT: Certificate No.: R07122709E Yuan Hsun Electric Co., Ltd. No. 57, Chung He Rd, Zuo-Ying Dist., Kaohsiung City 813, Taiwan R.O.C. Quad photobeam detector Quad-200CS

More information

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz Reference No.: WTU15U0933879E Page 2 of 45 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result

More information

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd. EMC Testing Report Equipment Under Test: Model Number: Serial No.: Applicant: Address of Applicant: Multi-Frequency (4 Channel Selectable) Twin Photobeam Detector Dual-120CS Dual-90CS, Dual-60CS, Dual-30CS

More information

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25 15072259 001 Seite 2 von 25 Page 2 of 25 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE 4.1.4 DISCONTINUOUS INTERFERENCE

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Variant Model Name: Applicant: CAMERA HOUSING SAMSUNG TECHWIN CO., LTD. SCX-FH200B SHB-4200 SAMSUNG TECHWIN

More information

1 SUMMARY OF STANDARDS AND RESULTS

1 SUMMARY OF STANDARDS AND RESULTS 1 SUMMARY OF STANDARDS AND RESULTS 1.1 Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below: EMISSION Description of Test Item Standard

More information

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China EMC-Report No.:SZZCT1502030B-EMC-02 EMC Test Report Product Model Number : Drift car : P01 Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

More information

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 11

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 11 Page : 2 / 38 TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST 4 3.1 CONDUCTED EMISSION TEST 7 3.2 RADIATED EMISSION TEST 11 3.3 ELECTROSTATIC DISCHARGE IMMUNITY TEST 14

More information

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23 D I R E C T O R Y A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23 B) Test data: Immunity against Electrostatic discharge

More information

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27 15072768 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE

More information

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed 17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:

More information

2620 Modular Measurement and Control System

2620 Modular Measurement and Control System European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic

More information

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003 Page: 1 of 20 EMC TEST REPORT Reference No. Applicant : WT05060412 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Cable Standards Model No : UAS111-M, UAS111, UAS112 : EN55022:1998+A2:2003

More information

FCC TEST REPORT. Table of Contents. FCC Measurement Report

FCC TEST REPORT. Table of Contents. FCC Measurement Report Table of Contents FCC Measurement Report 1. Introduction 2. Product Information 3. Description of Tests 4. Test Condition 5. Test Results 5.1 Summary of Test Results 5.2 Radiated Emissions Measurement

More information

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Report for Excelsys on EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B Rev Date Comment A April 2007 Change in DoC content B May 2007 Added Immunity Section EMT is a TÜV Appointed

More information

CE CONFORMANCE REPORT

CE CONFORMANCE REPORT Accredited Testing Laboratory under the terms of ISO/IEC 17025 CE CONFORMANCE REPORT EMC DIRECTIVE 2004/108/EC for PRODUCT: HIGH DEFINITION NETWORK CAMERA MODEL NAME: LND5110 AUTHORIZED LG Electronics

More information

EMC test report AU01+E04

EMC test report AU01+E04 Customer: Altuflevskoye shosse,h.48,bld.1pr.1,room39 Moscow,127566 Russia EMC test report 130504-AU01+E04 This test report may not be copied or published in a part without the written authorization of

More information

EMC Test Report. Report Number: M030826

EMC Test Report. Report Number: M030826 Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report

More information

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments EMC Page 3 / 33 Test report No.: EN 61000-6-3:2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Date of measurement: 2013-10-16

More information

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC VERIFICATION SUMMARY Report No.: SZHH EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA

More information

EMC TEST REPORT. according to

EMC TEST REPORT. according to EMC TEST REPORT according to European Standard EN 55022:2006/A1:2007 Class B, EN 61000-3-2:2006, EN 61000-3-3:1995/A1:2001/A2:2006, EN 55024:1998/A1:2001/A2:2003 (IEC 61000-4-2:Edition 1.2:2001-04, IEC

More information

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45 REPORT NO. PRSZ15110502E EMC TEST REPORT For Boardcon Technology Limited. MINI9G45 Computer on Module Model No. : MINI9G45 Prepared For : Boardcon Technology Limited. : Room 702, Hua Feng Xin An Business

More information

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA Shenzhen BST Technology Co., Ltd. ITUNER NETWORKS CORPORATION EMC REPORT Prepared For : ITUNER NETWORKS CORPORATION 47801 Fremont Blvd. Fremont, CA. 94538 Product Name: PicoPSU-150 Trade Name: PicoPSU

More information

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC standards. Presented by: Karim Loukil & Kaïs Siala Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards

More information

ELECTRONICS TESTING CENTER(ETC), TAIWAN

ELECTRONICS TESTING CENTER(ETC), TAIWAN File No. : 06-03-RBF-111-01 EMC TESTING DEPARTMENT II Page: 1 / 35 TEST REPORT Responsible Party Manufacturer Description of Product Trade Name : Huan Vu Enterprise Co., Ltd. : Huan Vu Enterprise Co.,

More information

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A EMC Test Report Applicant: Address of Applicant: Trade Name: FATEK AUTOMATION CORP. 26FL, NO.29, SEC.2, JUNGJENG E. RD., DANSHUEI DIST., NEW TAIPEI CITY, TAIWAN, R.O.C. FATEK Equipment Under Test: Training

More information

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by  Project Number EMT08J027 Report for Excelsys on EMC Measurements for 6Xgen Purchase Order: by email Project Number EMT08J027 Tom O Brien, Engineering Director ElectroMagnetic Technologies Ltd, Cork, June 2007 Executive Summary

More information

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758 Page 1 of 20 Report No. R011604553E EMC TEST REPORT for DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., LTD. Electronic calculator Model No.: KF15758 Prepared for Address Prepared by Address : DONGGUAN EVER

More information

Revision history. Revision Date of issue Test report No. Description KES-E Initial

Revision history. Revision Date of issue Test report No. Description KES-E Initial Page (2) of (52) Revision history Revision Date of issue Test report No. Description - 02.06.2012 Initial Page (3) of (52) TABLE OF CONTENTS 1 General Information 4 2 Product Labelling Requirements 8 3

More information

EMC TEST REPORT For CE

EMC TEST REPORT For CE EMC TEST REPORT For CE Test Report No. : CTK-2013-01069 Date of Issue : 2013-07-02 Kind of Product : FnIO S-Series Basic Model/Type No. : NA-9211, ST-5725, ST-5726 Variant Model/Type No. : NA-9212 Applicant

More information

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name: Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator EAST ZTY-30KVA Date of Receipt : Aug. 30, 2013 Date of Test: Sep. 03, 2013

More information

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8 EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8 Prepared for Address : ShenZhen ZhangQing Electronic LTD :

More information

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd Page 1 of 15 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EN61326 EMC COMPLIANCE

More information

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS Prepared For : Prepared By : Changzhou Airwheel Technology Co.,Ltd. Fl.5, East of No. 10 Building, high-tech

More information

DIRECTORY - EMISSIONS

DIRECTORY - EMISSIONS DIRECTORY - EMISSIONS A) Documentation Pages Test Report 1-12 Directory 2 Test Regulations 3 General Remarks and Summary 12 Test Setups (Photographs) 13-16 B) Test Data Conducted Emissions 9/150/450 khz

More information

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by

More information

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Page 1 of 18 EMC TEST REPORT Report No.: TS08100063-EME Model No.: 33XR-A Issued Date: Jan. 08, 2009 Applicant: Test Method/ Standard: Test By: FLUKE CORP. 6920 Seaway Blvd, M/S 266D Everett, WA 98203

More information

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B Page 1 of 27 Report No. R011412016E-1 EMC TEST REPORT for LEDELS LIGHTING CO., LTD LED module Model No. : LL-F12T4815X6B Prepared for : LEDELS LIGHTING CO., LTD Address : 5F, Block C, Mingjinhai Ind. Park,

More information

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by EMC TEST REPORT For KST DIGITAL TECHNOLOGY LIMITED Coreless Servo Model No.: X12-508 Additional Model No.: DS215MG, DS315MG, DS213MG, DS313MG, DS12C, DS12T, X12-306 Prepared for Address : KST DIGITAL TECHNOLOGY

More information

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017 EN 301 489-17 v3.1.1 TEST REPORT FOR Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017 Prepared for Texas Instrument 2900 Semiconductor Drive Santa

More information

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name: APPLICATION FOR EMC DIRECTIVE On Behalf of Shenzhen Qinhan Lighting Co., Ltd led flood light Trade Name: Model: QH-TGC-400W, QH-TGC-300W, QH-TGC-500W, QH-TGC-800W, QH-TGC-1000W Prepared For : Shenzhen

More information

IST EMC LAB. EMISSION TEST REPORT. : DSP-4284GM Basic Alternate. : PDP(Plasma Display Panel) : Daewoo Electronics Corp. : Daewoo Electronics Corp.

IST EMC LAB. EMISSION TEST REPORT. : DSP-4284GM Basic Alternate. : PDP(Plasma Display Panel) : Daewoo Electronics Corp. : Daewoo Electronics Corp. EMISSION TEST REPORT Test report file No. : 02-IST-241/FA Date of issue : Nov. 20, 2002. Model / Type No. Kind of product Brand name Applicant Manufacturer Address : DSP-4284GM Basic Alternate : PDP(Plasma

More information

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated Shenzhen CTL Testing Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-26636041 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances, electric tools

More information

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20 Shenzhen Toby Technology Co., Ltd. Report No.: TB-EMC125641 Page: 1 of 20 EMC Test Report Application No. : TB12114299 Applicant : Newmb Technology Co., Ltd. Equipment Under Test (EUT) EUT Name : USB HUB

More information

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CGZ3150428-00472-E-R1 2/F., South Tower, Huoju Building, No.181, Canghai Road,

More information

Test Report. Electromagnetic Compatibility Testing

Test Report. Electromagnetic Compatibility Testing Project: 04ME02062 File: E172861 Date: 2/04/2004 Model: GTM1089/GTM1096 & GTM1097 Series Test Report On Electromagnetic Compatibility Testing Copyright 2003 Underwriters Laboratories Inc. Underwriters

More information

9. Electrostatic Discharge Immunity Test (ESD)

9. Electrostatic Discharge Immunity Test (ESD) 9. Electrostatic Discharge Immunity Test (ESD) Test Mode: Mode 1 Final Test Result : PASS Pass Performance Criteria : A Required Performance Criteria: B Basic Standard : IEC 61000-4-2:Edition 1.2:2001-04

More information

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CNB3150602-00399-E 2/F., South Tower, Huoju Building, No.181, Canghai Road,

More information

Page: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6

Page: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6 Page: 1 of 41 EMC TEST REPORT Reference No. Applicant : WT05060416 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Multi-socket with surge protection Standards Model No. : SPG3-B-10,

More information

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University Overview of EMC Regulations and Testing Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University What is EMC Electro-Magnetic Compatibility ( 電磁相容 ) EMC EMI (Interference) Conducted

More information

Test Report for Part 15

Test Report for Part 15 Test Report for Part 15 Report number: STD-FCC-11020 Type of EUT: Speed Dome Camera Model number: Family Model: DOH-240SE DSC-230SE, DSC-270SE, DSC-600SE, DSC-300SE, DSC-300SE5, DSC-728SE, DSC-737SE Applicant:

More information

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U EN 301 489-17 v1.2.1 (2002-08) TEST REPORT FOR 802.11n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U11615-3 ISSUE DATE: FEBRUARY 29, 2008 Prepared for ATHEROS COMMUNICATIONS, INC.

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: Network Encoder SAMSUNG SPE-100 SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

Test Report GUANGDONG EAST POWER CO., LTD

Test Report GUANGDONG EAST POWER CO., LTD Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA906IIRTS, EA906IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014

More information

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China 4317137.50 EMC Test report for LED Fixed luminaires Models LED12036-1R, LED12036-2TU, LED120363R, LED12036-4TU2, LED12036-6TR, LED12036-1R CHR, LED12036-2TU CHR, LED12036-3R CHR, LED12036-4TU2 CHR, LED12036-6TR

More information

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD Page 1 of 45 Report No. R011607240E EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD INVERTER CHARGER Model No.: PV35-4K DC24V MPK, PV35-4K DC48V MPK, PV35-5K DC48V MPK, PV35-6K DC48V MPK Prepared

More information

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49 The following information was submitted and identified by/on behalf of the client as: Applicant : Ningbo Shanhuang Electric Appliance

More information

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for Report No.: 9A042401C2 Page 1 of 36 EN 50121-4: 2006 Product: Industrial IEEE 802.11a/b/g Dual-RF AP/Bridge/Client Trade Name: MOXA Model Number: AWK-5222 Prepared for MOXA Inc. Fl.4, No.135, Lane 235,

More information

FCC TEST REPORT. Table of Contents. Report no. ETLE , Page 2 of 21

FCC TEST REPORT. Table of Contents. Report no. ETLE , Page 2 of 21 FCC TEST REPORT Table of Contents FCC Measurement Report 1. Introduction 2. Product Information 3. Description of Tests 4. Test Condition 5. Test Results 5.1 Summary of Test Results 5.2 Conducted Emissions

More information

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-89486194-805 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances,

More information

Page: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK

Page: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK Page: 1 of 46 Reference No. Applicant : WT05060414 EMC TEST REPORT : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Advanced surge protection Model No. : SISF, SISF-2, SISFN-BLACK,

More information

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi EMC TEST REPORT For Shenzhen Ruideou Keji Youxian Gongsi Product Name: Trademark: Milligram Scale WAOAW Model Number: W-01-50 Prepared For : Address: Prepared By : Address: Shenzhen Ruideou Keji Youxian

More information

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co. ETSI EN 301 489-1 V2.2.0 (2017-03) ETSI EN 301 489-3 V2.1.1 (2017-03) TEST REPORT For United GULF GATE Co. Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT Model: XT-10P Report Type: Amended Report

More information

EMC Testing Report. StarCam Genie N/A MICRO-STAR INT L CO., LTD.

EMC Testing Report. StarCam Genie N/A MICRO-STAR INT L CO., LTD. EMC Testing Report Equipment Under Test MSI StarCam Genie Model Number Serial No. Applicant Address of Applicant StarCam Genie N/A MICRO-STAR INT L CO., LTD. No.69, Lide St., Jhonghe City, Taipei County

More information

EMISSION TEST REPORT

EMISSION TEST REPORT Page 1 of 23 EMISSION TEST REPORT Test Report No. Applicant Address Manufacturer Address Type of Equipment Model Name Serial number Total page of Report : E05OR-057 : Win4NET Co., Ltd. : KOLON Digital

More information

FCC MEASUREMENT REPORT

FCC MEASUREMENT REPORT www.etl.re.kr E-RAE Testing Laboratory Electromagnetic Emission FCC MEASUREMENT REPORT CERTIFICATION OF COMPLIANCE FCC Part 15 Certification Measurement PRODUCT : MODEL/TYPE NO : WT-1020 FCC ID : Q9QWT-1020

More information

EMC Test report for LED Panel Light Models , , , , ,

EMC Test report for LED Panel Light Models , , , , , 4326247.50 EMC Test report for LED Panel Light Models 000529, 000530, 000531, 000532, 000535, 000536 Guangzhou, date of issue: 2016-02-24 Author:Jazz Liang By order of Marvo Verlichting B.V. at Hoogeveen,

More information

C E R T I F I C A T I O N

C E R T I F I C A T I O N C E R T I F I C A T I O N Applicant Address Manufacturer Address : American Power Conversion Holding Inc. Taiwan Branch : 3F., No. 205, Sec. 3, Beixin Rd., Xindian Dist., New Taipei City 231, Taiwan R.O.C.

More information

Description of Version

Description of Version Description of Version Edition No. Data of Revision Revision Summary Report No. 0 February 07, 2017 Original Report BWS-17-EC-0015 This Test Report shall not be reproduced, except in full, without the

More information

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 10

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 10 TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST 4 3.1 CONDUCTED EMISSION TEST 7 3.2 RADIATED EMISSION TEST 10 80, Jeil-ri, Yangji-myun, Cheoin-gu, Yongin-si, Gyeonggi-do,

More information

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC. Report No.: UNI2016121702ER-01 Page 1 / 30 ShenZhen KY Technology Co.,Ltd EMC REPORT Prepared For: ShenZhen KY Technology Co.,Ltd Product Name: Smart bracelet No.369, BaoTian 1st RD, TieGang Industrial

More information

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

Guangdong East Power Co., Ltd. Uninterruptible Power Systems Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Uninterruptible Power Systems EAST EA8806, EA8804 Date of Receipt : Nov. 01, 2012 Date of Test: Nov. 03, 2012

More information

FCC TEST REPORT FCC ID: PFNDMS2344UHDW

FCC TEST REPORT FCC ID: PFNDMS2344UHDW Table of Contents FCC Measurement Report 1. Introduction 2. Product Information 3. Description of Tests 4. Test Condition 5. Test Results 5.1 Summary of Test Results 5.2 6 db Bandwidth 5.3 Maximum Peak

More information

EMISSION. EN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass

EMISSION. EN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass Reference No.: WTS14S0513592E Page 2 of 44 1 Test Summary EMISSION Test Item Mains Terminal Disturbance Voltage, 150kHz to 30MHz Telecommunication ports interference voltage, 150KHz to 30MHz Radiation

More information

SK Tech Co., Ltd.

SK Tech Co., Ltd. REVISION HISTORY Rev. # Changes of Content Section Affected Reviewed by Date 0 Original Release All S.H.Yoon Nov.18, 2011 Page 2 of 58 SUMMARY OF TEST RESULT EMISSION STANDARD ITEM CLASS/SEVERITY RESULT

More information

EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20

EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20 EMC TEST REPORT For Soma Medical (Sabah) Sdn Bhd (1248058-D) UVGI AIR STERILIZER Model No.: SM 20 Prepared For : Soma Medical (Sabah) Sdn Bhd (1248058-D) : Block E, Lot 28, 2nd floor, Signature Office,

More information

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass Seite 2 von 35 Page 2 of 35 TEST SUMMARY 5.1.1 HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Pass 5.1.3 CONDUCTED DISTURBANCE AT THE MAINS PORTS RESULT:

More information

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of, Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of, EN 301 489-1 V1.8.1 Electromagnetic compatibility and

More information

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10 CE/EMC TEST REPORT For HK QNOVATOR TECHNOLOGY CO.,LIMITED Product Name: Vacuum Tube Amplifier Trademark: Model Number: Prepared For: Address: Gemtune GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05,

More information

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46 TABLE OF CONTENTS 1. GENERAL INFORMATION...5 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)...5 1.2 OBJECTIVE...5 1.3 RELATED SUBMITTAL(S)/GRANT(S)...5 1.4 TEST METHODOLOGY...5 1.5 TEST FACILITY...5

More information

EMC Test Report. Shenzhen JT Detection Technology Co., Ltd. Product : Car LED headlight bulbs Brand Name :WEIYAO AUTO LED.

EMC Test Report. Shenzhen JT Detection Technology Co., Ltd. Product : Car LED headlight bulbs Brand Name :WEIYAO AUTO LED. EMC Test Report Product : Car LED headlight bulbs Brand Name :WEIYAO AUTO LED Model Number : V8 series,h1,h3,h4,h7,h11,h13,h16,9005,9004,9006,9007, 880,881,D2,PX26 Prepared for : Guangzhou WEIYAO auto

More information

Test Report. Product Name : PC2PC-Bluetooth Model No. : MS Date of Receipt : Apr. 22, Date of Test : May 09, Report No.

Test Report. Product Name : PC2PC-Bluetooth Model No. : MS Date of Receipt : Apr. 22, Date of Test : May 09, Report No. Report No. 024L064E Test Report Product Name : PC2PC-Bluetooth Model No. : MS-6967 Applicant : MICRO-STAR INT'L Co., LTD. Address : No. 69, Li-De St, Jung-He City, Taipei Hsien, Taiwan, R.O.C. Date of

More information

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE EMC TEST REPORT For SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD Product Name: Pure sine wave power inverter Trademark: Model : Prepared For : Address: Prepared By : Address: ML-1000W ML-300W---ML-8000W.

More information

ELECTRONICS TESTING CENTER, TAIWAN

ELECTRONICS TESTING CENTER, TAIWAN File No.: 09-06-MAS-242-03 EMC TESTING DEPARTMENT Page:1/12 CONFORMANCE TEST REPORT FOR EN 301489-1 / -17 Report No.: 09-06-MAS-242-03 Client: Product: Model: Manufacturer/supplier: Ezurio Limited. Bluetooth

More information

COMPLIANCE REPORT. Emission & Immunity of Electromagnetic disturbance

COMPLIANCE REPORT. Emission & Immunity of Electromagnetic disturbance COMPLIANCE REPORT Emission & Immunity of Electromagnetic disturbance Test Report No: Equipment: Type/Model: Family Model: Applicant: Manufacturer: STD-CE-11052 Speed Dome Camera DOH-240SE DSC-230SE, DSC-270SE,

More information

BUREAU VERITAS. itaste svd

BUREAU VERITAS. itaste svd BUREAU VERITAS TEST REPORT No.: (5213)095-0238 TEST REPORT To: INNOKIN TECHNOLOGY CO., LTD I Fax: I -- Attn: -- I -- I Address: Buildinq 6, XinXinTian Industrial Park, XinSha Road, Sha.Jinq street, ShenZhen,

More information

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan Page 1 of 32 EMC TEST REPORT Report No.: TS11020117-EME Model No.: NS-PSE, NS-POINTED, NS-PSQUARE, NS-PF-S, NS-PT, NS-PR, NS-PU, NS-PF-H, NS-BALIBA, NS-FLEXMA Issued Date: Mar. 01, 2011 Applicant: NORTE

More information

FCC TEST REPORT FCC ID: PFNDMS-2344UHDS

FCC TEST REPORT FCC ID: PFNDMS-2344UHDS Table of Contents FCC Measurement Report 1. Introduction 2. Product Information 3. Description of Tests 4. Test Condition 5. Test s 5.1 Summary of Test s 5.2 AC Power line Conducted Emissions Measurement

More information

EN v2.1.1 EN 55022: A1:2007 TEST REPORT FOR b/g/n 1x2 SISO NETWORKING DEVICE MODEL NUMBER: UNIFI AP MINI

EN v2.1.1 EN 55022: A1:2007 TEST REPORT FOR b/g/n 1x2 SISO NETWORKING DEVICE MODEL NUMBER: UNIFI AP MINI EN 301 489-17 v2.1.1 EN 55022:2006 + A1:2007 TEST REPORT FOR 802.11b/g/n 1x2 SISO NETWORKING DEVICE MODEL NUMBER: UNIFI AP MINI REPORT NUMBER: 11U14006-4 ISSUE DATE: FEBRUARY 8, 2012 Prepared for UBIQUITI

More information