1 Hartmann Wavefront Analyzer Installation & Setup Guide Ophir-Spiricon Inc. 60 West 1000 North Logan, UT For Sales, Service or Technical Support Phone (435) Fax (435) Copyright 2008, Ophir-Spiricon Inc., Logan, UT Document No Rev C , Rev C i

2 Contents Contents...ii Introduction Product Description Capabilities & Limitations... 2 Installation & Alignment Setting Up Your HWA Application and Computer Hardware Unpacking Packing List Installing the HWA Application Installing the Spiricon Frame Grabber Card Preliminary System Checkout Connecting the Sensor to the Computer Start Up Learning to Use the HWA Software Using the On-line Help Optical Alignment Overview of the Optical Setup Alignment Creating a Uniform Plane Wavefront Steps to Align the Sensor to the Incident Light Attenuation Laser Beam Wavefront Analysis Optical Component Testing Appendices A Installing the Hartmann Wavefront Analyzer Application B Installing the Frame Grabber Card B.1 Powering Up Your System for the First Time B.2 Special Notes for Windows Millennium Users C Your Specific Wavefront Sensor , Rev C ii

3 Introduction 1 Product Description The Hartmann Wavefront Analyzer (HWA) from Spiricon is a wavefront sensor data analysis application with one or more integrated Hartmann wavefront sensors. Sensor data is quickly recorded and converted to wavefront information by the HWA application and displayed in an easy to use graphical interface. Hartmann-style optical tests employ a geometric method for measuring wavefront slopes at discrete points (sub-apertures) across the aperture of the sensor. The HWA application then reconstructs the wavefront falling on that aperture. Optical path differences (OPD) are easily determined from the reconstructed wavefront. This geometric method, as opposed to interferometric methods, has some advantages. For example, the HWA does not require a coherent light source, it is just as useful with white light as with monochromatic and it is insensitive to vibration. Your HWA will accomplish many of the tasks performed by: 1. Interferometers 2. Beam profilers Your HWA will perform quantitative measurements for: 1. Surface metrology 2. Process monitoring 3. Optical testing 4. Beam analysis The quantitative beam analysis can be performed for a wide range of lasers with wavelengths from 400nm to 1064nm, CW or pulsed. Intensity and phase of the wavefront are measured simultaneously. Fully customizable user selectable displays include: 1. Live Video 2. Intensity Distribution (2D or 3D) 3. Phase Distribution (2D or 3D) 4. Wavefront Slope Vector Plot These displays may be printed or saved as Bitmaps for use in other applications. A text display of results for user selected calculations may include: , Rev C 1

4 1. Reconstructor Average Error. This is the average difference between the reconstructed wavefront slopes and the measured slopes. 2. Average Slopes (x direction, y direction) 3. RMS Slope (x direction, y direction) 4. Beam Centroid (This is the 1 st moment in the x direction and the y direction measured from the center of imager. Note that y increases going down, while x increases going to the right) 5. Beam Widths (x direction, y direction) This is the second moment based d d beam width ( ) σ, x σ y 6. Radius of Curvature of the Wavefront (x direction, y direction and average) 7. Fit Slopes (x direction, y direction) 8. Wavefront Minimum, Maximum and Peak to Valley (μm) 9. Wavefront RMS (μm), This is the rms measure of the phase of the reconstructed wavefront, sampled at the subapertures. 10. Zernike Polynomial Coefficients for a user defined number of polynomial terms. 11. Hermite Gaussian Mode Decomposition Percentages. This text display is available to the clipboard for importing into other applications. 2 Capabilities & Limitations The HWA has a range of capabilities the limits of which depend on the particular HWA model and the wavelength of the light being used. Each sensor has a limit on the minimum and maximum radii of curvature that can be detected, the resolution of the intensity pattern falling on the sensor and the minimum wavefront spatial period. For an explanation of the terms in this section, see the Hartmann Wavefront Analyzer Tutorial. For the limits of your particular sensor see appendix C. Each sensor has a minimum radius of curvature that it can detect since a smaller radius of curvature would send the diffracted spot from one aperture beyond its allowed integration area on the camera CCD array. A maximum on the radius of curvature detectable is related to the diffracted spot radius, which depends on the wavelength and the sub-aperture sizes. It is also related to the resolution of the camera sensor and to the algorithms used to detect a slight change in the centroid location of the diffracted spot. If the radius of curvature is larger than this maximum, then for all intents and purposes the radius is infinite (zero curvature) as far as this sensor can measure , Rev C 2

5 It is not possible for the intensity pattern falling on the sensor to be resolved any finer than the aperture spacing of the aperture array in the sensor. This spacing is also responsible for the limit on the wavefront spatial period. If the wavefront slopes change on a spatial frequency across the sensor that is greater than the spatial frequency of the apertures, then it will not be possible for the sensor to detect these fine details in the wavefront , Rev C 3

6 Installation & Alignment 3 Setting Up Your HWA Application and Computer Hardware 3.1 Unpacking Packing List Your HWA system will contain one or more of the following components. Refer to the packing list supplied with your system for actual components and quantities. HWA Documents Hartmann Wavefront Analyzer Installation & Setup Guide (this document), Rev B. Hartmann Wavefront Analyzer Tutorial, Rev E. Hartmann Style Sensor: HWA Sensor (Specially Modified CCD camera) Sensor Power Supply 1 Camera to Frame Grabber Card Interface Cable Camera to Frame Grabber Card BNC Cable Spiricon LBA X00PC Frame Grabber Card [If you purchased a PC with this instrument, the frame grabber card comes factory installed in the PC] Computer System Components: HWA Software Installation CD Pentium or higher PC running Windows 95/98 or higher Available Accessories ND filter set (1 inch) Tip/Tilt Sensor Mount Mirrors in Kinematic Mounts Inspect all equipment for any damage that may have occurred during shipment. If any damage is found, contact the shipper and Spiricon s service department at: (435) Whether or not your sensor requires a separate power supply depends on the camera type that your sensor is based on , Rev C 4

7 3.2 Installing the HWA Application Some systems will include a PC style computer pre-configured at the factory. The information in appendix A can be used to install the HWA application to computers not supplied by Spiricon. If your computer has been pre-configured at the factory, then you do not need to install the HWA application or the frame grabber card and should skip to section 3.4. If you need to install the HWA application in a computer system supplied by a source other than Ophir-Spiricon, refer to appendix A. 3.3 Installing the Spiricon Frame Grabber Card Some systems will include a PC style computer pre-configured at the factory. The information in appendix B can be used to install the frame grabber card in computers not supplied by Spiricon. If your computer has been pre-configured at the factory then you do not need to install the frame grabber card and should proceed to section 3.4. If you have installed the HWA application in a computer that will be used only off-line for analysis of previously recorded data, then you may skip this section and refer to the online help files available in the application. Any computer that will be connected directly to the HWA sensor requires a frame grabber card. To install a Spiricon frame grabber card in a computer not supplied by Spiricon refer to appendix B. 3.4 Preliminary System Checkout Connecting the Sensor to the Computer Before mounting the sensor, set it on a secure flat surface, connect the cables from the sensor (camera) to the installed frame grabber card. This step is done to test the sensor camera before setting up the equipment. Many cameras and HWA sensors purchased from Spiricon are supplied with a camera power cable. This cable will provide camera power directly from the frame grabber card. Plug this cable into the appropriate 9-pin (female) connector on the frame grabber card, and into the camera or sensor. If a separate power supply is required, connect it according to the instructions provided with the sensor instead of , Rev C 5

8 connecting a camera power cable to the frame grabber card. Connect the BNC cable from the video output of the sensor to the frame grabber card. (See Figure 1). If you purchased a digital sensor and a frame grabber card with digital camera input, then instead of the BNC cable, a digital input cable connects the camera digital output to an adaptor cable which connects to the frame grabber card digital input. Some cameras come with an additional camera control cable, usually connected to the camera and a serial port on the computer. Use of this cable requires camera control software separate from the HWA software from Spiricon. PC Style Computer FRAME GRABBER CARD BNC Cable Power Cable Power Cable HWA Sensor BNC Cable Figure 1 Connect the sensor to the frame grabber card in the PC to perform the preliminary test Start Up Start the HWA application by double clicking the HWA icon or launch it using Start, Programs, Spiricon, HWA , Rev C 6

9 You are now ready to make a preliminary test of the sensor. First click on the Setup menu , Rev C 7

10 A tabbed dialogue box will appear. Figure 2 Sensor Tab on the Setup Screen. Check to make sure the camera type is correct for your sensor. If the camera type is correct, click on OK. Make sure that the instrument is stopped, the instrument is stopped if there is a START button visible, don t click the START button. Click on Live Video. This is found on the Intensity window: , Rev C 8

11 Figure 3 Buttons found on the intensity window. Remove any cover from the sensor. Check to see that lighting changes are registered on the screen. Figure 4 Live Video display. At low enough light levels you should see an array of bright spots on the screen in the Live Video window and you should be able to observe some changes as you aim the sensor at various light sources in the room or shade the sensor completely using the cover. If this is the case, then the basic function of the sensor is intact, and the preliminary system checkout is done. In normal room light, the sensor will not show the tidy array of diffracted spots. Instead, it will display a completely saturated state with a white area, but it will respond to changes in the light level, for example if you cover the sensor you will see the bright area dim, with spots possibly showing and then go dark. As long as you get this response, the sensor is working properly , Rev C 9

12 3.5 Learning to Use the HWA Software An online User s Guide provides all of the information required to learn how to use the HWA application. The online user s guide is in an easy to navigate HTML format and describes the features and controls as well as some background information relevant to using the HWA application Using the On-line Help With the HWA application running, just click on the Help menu item. in the menu bar at the top of the screen, and choose HWA Online Help from the drop down menu. Online Help consists of four chapters, Basic Principles and Conventions, User Interface, Optical Setup and Appendices. The chapter Basic Principles and Conventions covers the operating principles of the instrument and the theory behind wavefront analysis. It also covers the software conventions and the algorithms used in Spiricon s HWA application. The second chapter, User Interface, describes the mechanics of navigating through the application including the various displays, options and settings. While using the application you should refer to the Online Help for any questions about how to use software features or what information is being displayed. Touch sensitive Hints and What s This help features are also available. For hints, simply leave the cursor over a button or control for a few seconds and a hint will appear to describe what the button does. For What s This help, click on the question mark on the tool bar and then click on the button or feature that you want to get help on. Spending a little time with the application using the features and controls is the best way to become familiar with and learn to use the HWA application and instrument. 4 Optical Alignment 4.1 Overview of the Optical Setup Your Hartmann Wavefront Analyzer is designed to measure, report and graphically display incoming optical wavefronts. Due to the limited dynamic range of the instrument, the incoming light or laser beam must be well aligned normal to the face of the sensor , Rev C 10

13 4.1.1 Alignment To perform metrology (either laser or optical) with the HWA, it is necessary to align the sensor as accurately as possible to the incoming beam or light source. An absolute reference file for your sensor has been created at the factory using a large flat wavefront. When the optical alignment is correct, a measured flat wavefront can be observed. Spiricon suggests using a mechanical mount that allows the sensor to be tilted about the two axes parallel to the sensor face (pitch & yaw of the instrument). These kinematic mounts are available from almost every major optical equipment supplier. Furthermore, a pair of orthogonal translation stages that allows the beam to be positioned accurately on the sensor is also useful, or the beam can be positioned using a pair of front surface reflecting mirrors. Tilt of the sensor with respect to an incoming beam must be kept within the dynamic range of the instrument. In other words, the initial alignment of the instrument with the beam to be tested (or incoming light from an optic under test) is critical. We suggest using the retro-reflection from the sensor to do the rough alignment. If the beam falling on the sensor is reflected back through the optics to the source of the beam, then the alignment will be close. If you know that you have a flat wavefront input, then you can use the HWA application to make the fine adjustments on the tip, tilt and transverse location of the sensor. One feature of the application that is useful for rough adjustment is to use live video in the intensity window and right click on the space below the tools to bring up a menu allowing you to turn on the display of the integration areas. When you do this, you can observe the positions of the diffracted spots relative to their respective integration areas. Rough alignment can be done by adjusting the tip and tilt of the beam or instrument to center the spots in their integration areas , Rev C 11

14 Creating a Uniform Plane Wavefront A uniform plane wave will often be desirable. This is the wavefront that will often be modified by optics to be tested (see section 4.3). This can be accomplished in several ways, two of which are described below , Rev C 12

15 The simplest method for creating a flat wavefront is to use a point source and a collimating lens. This may be done with monochromatic or white light, note however, that wavelength dependent effects will be masked when using white light. A fiber-optic coupled diode laser can serve very well as a point source. A collimating lens is placed one focal length away from the output of the fiber optic. In order to get a nearly uniform illumination, the focal length should be large enough that the output angle of fiber optic, calculated from the numerical aperture by θ = arcsin(na a ), has enough distance to over fill the lens. An aplanat lens is the best possible choice for making good reference wavefronts, but achromats or even plano-convex lenses can be used. In the case of achromats and plano-convex lenses it is usually best to face the least curved or flat side of the lens toward the point source. It is also desirable to use a lens with an F/# greater than 5. Final fine adjustment of the distance between the lens and the output of the fiber optic should be performed after the alignment is accomplished and the HWA instrument can be used to gauge the resultant wavefront curvature. Fiber Optic Output Collimating Lens HWA Sensor Fiber Coupled Laser Source Figure 5 A fiber optic coupled laser source acts as a point source. A collimating lens one focal length away gives plane wave output. In lieu of a fiber optic point source, a laser focused on a pinhole aperture may be used. In this case, the size of the output plane wave will depend on the ratio of the collimating lens focal length to the focusing lens focal length and the size of the input laser beam. Pinhole Aperture Collimating Lens HWA Sensor Input Laser Beam Focusing Lens Figure 6 A laser beam focused on a pinhole aperture can serve as a point source , Rev C 13

16 Of course, mirrors can be used as is often done in infrared collimators, to obtain high quality flat wavefronts. The absolute reference file is used when performing either laser metrology or optical metrology with the Hartmann Wavefront Analyzer. Before a measurement can be made using the absolute reference file, the sensor must be aligned to the incident light. This can be difficult to do since the dynamic tilt range of these sensors can be as small as less than a degree depending on the sensor model, but by following the procedure below an accurate sensor alignment can be obtained quite reliably. Follow these steps to align the sensor: Steps to Align the Sensor to the Incident Light Coarse alignment: Roughly align the reflection of the incident light from the sensor back upon itself. Place an aperture in the beam that is illuminating the sensor as far away from the sensor as possible. It is probably easiest to do this such that there are no optics between the aperture and the HWA sensor. The aperture does not have to be a complex optical component, a simple pinhole in an opaque material will do. Adjust the pitch and yaw of the sensor such that the light reflected from the aperture array passes back through the aperture , Rev C 14

17 Figure 7 Adjust the Pitch and Yaw of the sensor until the reflection from the sensor goes back through the aperture in the card. Now the coarse alignment is accomplished and you can use the HWA application to perform the fine adjustments to the alignment. Fine alignment: Start the HWA software on your computer. Press to begin acquiring and processing frames. Adjust the pitch and yaw of the sensor mount to minimize the average wavefront slope by either monitoring the average slope value in the Results window or by monitoring the graphical wavefront slope representation in the Slopes window , Rev C 15

18 Figure 8 Slopes window, you are trying to get displacement vectors as small as possible and fluctuating randomly instead of all in one direction as shown here. Once you are satisfied with the alignment, click the button to stop frame acquisition. Examine the Last Image Analyzed in the Intensity window. Figure 9 The Last Image Processed window is available in the intensity window. You should see a regular array of bright spots , Rev C 16

19 Overlay the integration areas by clicking on. Look at the positions of the diffracted spots in the image. If the spots are roughly in the centers of the integration areas, then you have achieved proper alignment. Because the optical wavefront can be converging or diverging, sometimes the diffracted spots can be centered in one part of the image and towards the edges as you move increasingly outward. In this case, the spots should be centered in the integration area boxes at the center of the image and possibly be closer to the edges of the integration areas as you move further from the center. If the diffracted spots touch or cross over the integration areas, you have exceeded the dynamic range of the sensor and cannot measure the incident wavefront Attenuation The HWA sensor is very sensitive to input light. Attenuation of the light source may be required in order to keep the intensity within the dynamic range of the HWA sensor. Bulk absorbing neutral density (ND) filters can reduce the light intensity and lessen the effects of room light, but they will introduce spurious wavefront errors. In some cases these errors may be compensated for by creating reference files with the ND filters in place. A better solution is to attenuate using front surface reflection, or attenuate the light source before the wavefront is shaped, for example attenuating the light going into a fiber optic before it emerges and is collimated by a lens. The saturation indicator,, will alert you with a red light if the intensity is too high for making measurements. You should use enough attenuation to keep just below saturation , Rev C 17

20 4.2 Laser Beam Wavefront Analysis Proper alignment of the laser beam to the sensor is critical. In all cases the beam should be very nearly perpendicular to the face of the sensor. Laser beam analysis requires the use of the Absolute reference file created at the factory. Sampling and attenuation of the laser beam must also be done with care not to severely distort the wavefront of the beam to be analyzed. This requires high quality mirrors or other optics with minimal distortion. It is usually a good idea to use a reflective type sampling of the laser beam using some type of beam splitter, such as Spiricon s Beam Tap II shown in Figure 10, rather than directly shining the laser into the HWA sensor or requiring ND filters to provide all of the attenuation. This reflective sampling is usually the best preliminary attenuation of laser beam before analysis. Measurements should be done with the intensity just below the saturation level. The saturation indicator will alert you to an intensity above the optimum level for making measurements , Rev C 18

21 Sampled Beam Input Beam Figure 10 Schematic of Spiricon's Beam Tap II. An input beam is reflectively sampled resulting in a faithful, attenuated representation of the beam. Coarse alignment should usually be performed with the sampler, such as the Beam Tap, in place but without the further attenuation of the ND filters. This way the beam reflected from the surface of the sensor is bright enough to be seen, and you are watching the reflection from the surface of the sensor and not from the surface of an ND filter. ND filters should be put into place before using the application to perform the fine adjustment , Rev C 19

22 Figure 11 Use the 2 nd mirror to get the retro-reflection from the surface of the sensor to go back into the source. Then the beam is normal to the surface of the sensor. Figure 12 Use the 1 st mirror to adjust the position of the beam (center it on the sensor) and then again use the 2 nd mirror to get the retroreflection back to the source. This way the beam is both centered on and normal to the sensor. Adjustment should generally be done using a pair of mirrors as shown in Figure 11 and Figure 12. This is the easiest way to obtain the required angle and position of the beam. This pair of mirrors should usually be positioned after the sampler since too many reflections in the sampler are difficult to visualize and account for during adjustment of mirrors placed before the sampler. The two figures describe an iterative process, using the 2 nd mirror to get the sampled laser beam normal to the surface of the sensor and then using the 1 st mirror to adjust the centering of the beam on the sensor. Of course, each adjustment of one mirror creates the need to readjust the other until the coarse alignment is accomplished , Rev C 20

23 Further attenuation will often be required and should include ND filters just before the sensor. This reduces the effect of ambient light and wavefront distortion that can be caused by ND filters. However, it may still be necessary to use further attenuation after the reflective sampler and before the final attenuation, in which case care should be taken to avoid distortion. Figure 13 The whole system should consist of a reflective beam sampler, beam positioning mirrors and ND filter attenuation , Rev C 21

24 4.3 Optical Component Testing Spiricon s Hartmann Wavefront Analyzer can be used to test optical surfaces. Many configurations are possible for quantitative testing of optical components. Those arrangements shown here do not comprise an exhaustive list, but are presented to suggest just a few possibilities. Since many configurations will depend on it, the first consideration is how to create a point source. Two possible methods are shown in Figure 14. Pinhole Laser Source HWA Sensor Effective Point Source Single Mode Fiber HWA Sensor Fiber Coupled Laser Figure 14 Two possible methods for creating a point source. Note: Your point source does not have to be a laser or monochromatic. 2 Lenses may be tested as they are used to collimate your point source as shown in Figure When using white light, wavelength dependent results such as the times diffraction limit factor are not valid , Rev C 22

25 Point Source HWA Sensor Test Lens Point Source HWA Sensor Test Lens Afocal Relay Figure 15 The lens under test may be used as the collimating lens. A reference can be made using a known lens or by removing the lens under test and placing the point source far from the sensor or afocal relay and sensor combination. The afocal relay may or may not be required for your application. Mirrors may be tested as shown in Figure 16, Figure 17 and Figure 18. The general rule is to create a flat wavefront with the test optic and observe the aberrations in comparison to the absolute reference file or to a relative reference file created using a similar setup , Rev C 23

26 Reference Mirror Beam Splitter Test Mirror Afocal Relay HWA Sensor Collimating Lens Point Source Figure 16 Flat mirrors may be tested with or without a reference. Light from either the reference or the test mirror should be viewed. They should not be viewed simultaneously. Curved mirrors can also be tested in this configuration, again with or without a reference. In this case the point source may be placed at the focal point of the curved mirror and the collimating lens can be left out. Beam Expander Beam Splitter Afocal Relay HWA Sensor Test Mirror Collimating Lens Point Source , Rev C 24

27 Figure 17 Curved mirrors can be tested as they are used in a beam expander. Beam Splitter Afocal Relay HWA Sensor Test Mirror Point Source Figure 18 It is also possible to test curved mirrors by placing the point source at the focal point of the mirror. The afocal relay may not be required in your tests , Rev C 25

28 Appendices A Installing the Hartmann Wavefront Analyzer Application If you purchased your HWA from Spiricon with a computer system and installation, then the HWA software and frame grabber card will already be installed and you can skip this Section. To install the LBA-PC Application Program in a Windows 95, 98, NT, 2000 or an XP system: (See special notes for 2000 system users.) 1. Start Windows. 2. Close all other Windows applications. 3. Place the Spiricon CD into your CD-ROM drive. 4. From the Taskbar, click on Start, then Run In the Open line type: R:\Spiricon\setup.exe <Enter> Where R is the letter of your CD-ROM drive. 6. Follow any directions that appear on your screen. NOTE: After the installation is completed, you must exit and restart Windows before running the HWA program. Be sure to look at the HWA ReadMe text, before starting the HWA application. This will bring you up to date with any last minute information regarding the current version of the program , Rev C 26

29 B Installing the Frame Grabber Card Any computer that will be connected to one of Ophir-Spiricon s Hartmann Wavefront Analyzers requires a Spiricon frame grabber card. A frame grabber card is not required in a computer that will only be used to view HWA data collected on another computer. If your computer has been pre-configured at the factory, then the frame grabber card has already been installed and tested. CAUTION Electrostatic Discharge can result in permanent damage to electronic equipment. Always ground yourself by touching the system cabinet before beginning the following procedure. We strongly recommend using an anti-static wrist strap attached to earth ground. To install the frame grabber card: Disconnect the power to the PC and remove the cover as described in the computer s technical manual. Locate PCI bus slots. Most PC s will have 2, 3 or 4 PCI slots. Often, one will have a graphics card installed. Select an unused PCI slot and remove the rear filler plate associated with that slot. (See Figure 19) Figure 19: PCI bus slots , Rev C 27

30 Carefully plug the frame grabber card into the PCI slot. (See Figure 20) Make sure that it is fully seated in the PCI connector. Secure the end bracket with the screw that held in the filler plate. Figure 20: Plug the frame grabber card into the PCI slot. Do this step only if you purchased wavefront sensor based on a Digital Camera. To install the optional digital camera adapter, make sure that the slot immediately to the left (viewed from the front of the PC) of the above PCI slot is also empty, and remove its rear filler plate. If this slot is not empty then relocate the frame grabber card or the card that is occupying this slot. The digital camera adapter uses this rear panel opening, but does not plug into any of the PC expansion slots. Rather, it is provided with a short ribbon cable that plugs into the fame grabber card. (See Figure 21) Slide the digital camera adapter into the rear opening and plug its cable into the frame grabber card. Secure the adapter bracket to the rear panel with the screw that held in the filler plate , Rev C 28

31 Figure 21: Optional digital camera adapter. Replace the cover and reconnect the A/C power to the PC. B.1 Powering Up Your System for the First Time Computer systems pre-configured at the factory have been through the steps in this section. If Spiricon supplied your computer, you can skip to section 3.4. If you have installed the frame grabber card yourself it will automatically detected on startup. A new PCI device named LBA-PC will be automatically installed. This device will be found in the Device Manager under Sound, Video and Game Controllers. It is necessary to restart Windows after the installation procedure , Rev C 29

32 B.2 Special Notes for Windows Millennium Users Spiricon has successfully installed all of our Windows based applications in the Windows Millennium Edition environment and have seen no operating difficulties. We are however aware of a large number of ME users experiencing problems with the ME operating system. The range of difficulties being reported is too numerous for a serious discussion in this manual. We consider this to be part of the normal Windows operating system shakedown process, and that if you experience a good Windows ME installation on your PC, we would expect no further problems with loading and running our applications , Rev C 30

33 C Your Specific Wavefront Sensor Model Number: Serial Number: Absolute Reference file: Original Setup File: Camera Type: Aperture Array Wavelength: Aperture Array Subaperture pitch: (μm) Aperture Array Subaperture diameter: (μm) RMS wavefront error measured: (μm) Calibration Date: , Rev C 31

34 Index achromats, 10 Align the Sensor, 11 Alignment, 3, 8 aplanat, 10 Attenuation, 14 Beam analysis, 1 Beam profiler, 1 Beam Width, 2 camera, 3, 4, 24, 25 Centroid, 2 Coarse alignment, 11, 16 Computer System, 3 digital camera adapter, 25 factory, 3, 4, 9, 15, 23, 25 fine adjustment, 10, 16 Frame Grabber Card, 3, 4, 23 Gaussian, 2 geometric method, 1 Hartmann Style Sensor, 3 Hartmann-style optical tests, 1 HWA Application, 3, 4, 22 Installation, 3 Intensity Distribution, 1 Interferometer, 1 Laser Beam Wavefront Analysis, 15 Live Video, 1 ND filter, 3, 16, 17 Online Help, 8 OPD, 1 Optical Alignment, 8 Optical Component, 18 Optical testing, 1 Phase Distribution, 1 Plane Wavefront, 10 Process monitoring, 1 Radius of Curvature, 2 Reconstructor, 1 Software, 3, 8 Surface metrology, 1 System Checkout, 4 Wavefront Slope, , Rev C 32

AgilEye Manual Version 2.0 February 28, 2007

AgilEye Manual Version 2.0 February 28, 2007 AgilEye Manual Version 2.0 February 28, 2007 1717 Louisiana NE Suite 202 Albuquerque, NM 87110 (505) 268-4742 support@agiloptics.com 2 (505) 268-4742 v. 2.0 February 07, 2007 3 Introduction AgilEye Wavefront

More information

Hartmann Sensor Manual

Hartmann Sensor Manual Hartmann Sensor Manual 2021 Girard Blvd. Suite 150 Albuquerque, NM 87106 (505) 245-9970 x184 www.aos-llc.com 1 Table of Contents 1 Introduction... 3 1.1 Device Operation... 3 1.2 Limitations of Hartmann

More information

Breadboard adaptive optical system based on 109-channel PDM: technical passport

Breadboard adaptive optical system based on 109-channel PDM: technical passport F L E X I B L E Flexible Optical B.V. Adaptive Optics Optical Microsystems Wavefront Sensors O P T I C A L Oleg Soloviev Chief Scientist Röntgenweg 1 2624 BD, Delft The Netherlands Tel: +31 15 285 15-47

More information

INTERFEROMETER VI-direct

INTERFEROMETER VI-direct Universal Interferometers for Quality Control Ideal for Production and Quality Control INTERFEROMETER VI-direct Typical Applications Interferometers are an indispensable measurement tool for optical production

More information

WaveMaster IOL. Fast and accurate intraocular lens tester

WaveMaster IOL. Fast and accurate intraocular lens tester WaveMaster IOL Fast and accurate intraocular lens tester INTRAOCULAR LENS TESTER WaveMaster IOL Fast and accurate intraocular lens tester WaveMaster IOL is a new instrument providing real time analysis

More information

Be aware that there is no universal notation for the various quantities.

Be aware that there is no universal notation for the various quantities. Fourier Optics v2.4 Ray tracing is limited in its ability to describe optics because it ignores the wave properties of light. Diffraction is needed to explain image spatial resolution and contrast and

More information

ADVANCED OPTICS LAB -ECEN 5606

ADVANCED OPTICS LAB -ECEN 5606 ADVANCED OPTICS LAB -ECEN 5606 Basic Skills Lab Dr. Steve Cundiff and Edward McKenna, 1/15/04 rev KW 1/15/06, 1/8/10 The goal of this lab is to provide you with practice of some of the basic skills needed

More information

WaveMaster IOL. Fast and Accurate Intraocular Lens Tester

WaveMaster IOL. Fast and Accurate Intraocular Lens Tester WaveMaster IOL Fast and Accurate Intraocular Lens Tester INTRAOCULAR LENS TESTER WaveMaster IOL Fast and accurate intraocular lens tester WaveMaster IOL is an instrument providing real time analysis of

More information

Supplementary Materials

Supplementary Materials Supplementary Materials In the supplementary materials of this paper we discuss some practical consideration for alignment of optical components to help unexperienced users to achieve a high performance

More information

ADVANCED OPTICS LAB -ECEN Basic Skills Lab

ADVANCED OPTICS LAB -ECEN Basic Skills Lab ADVANCED OPTICS LAB -ECEN 5606 Basic Skills Lab Dr. Steve Cundiff and Edward McKenna, 1/15/04 Revised KW 1/15/06, 1/8/10 Revised CC and RZ 01/17/14 The goal of this lab is to provide you with practice

More information

Reference and User Manual May, 2015 revision - 3

Reference and User Manual May, 2015 revision - 3 Reference and User Manual May, 2015 revision - 3 Innovations Foresight 2015 - Powered by Alcor System 1 For any improvement and suggestions, please contact customerservice@innovationsforesight.com Some

More information

AgilOptics mirrors increase coupling efficiency into a 4 µm diameter fiber by 750%.

AgilOptics mirrors increase coupling efficiency into a 4 µm diameter fiber by 750%. Application Note AN004: Fiber Coupling Improvement Introduction AgilOptics mirrors increase coupling efficiency into a 4 µm diameter fiber by 750%. Industrial lasers used for cutting, welding, drilling,

More information

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Mechanical Engineering Department. 2.71/2.710 Final Exam. May 21, Duration: 3 hours (9 am-12 noon)

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Mechanical Engineering Department. 2.71/2.710 Final Exam. May 21, Duration: 3 hours (9 am-12 noon) MASSACHUSETTS INSTITUTE OF TECHNOLOGY Mechanical Engineering Department 2.71/2.710 Final Exam May 21, 2013 Duration: 3 hours (9 am-12 noon) CLOSED BOOK Total pages: 5 Name: PLEASE RETURN THIS BOOKLET WITH

More information

Kit for building your own THz Time-Domain Spectrometer

Kit for building your own THz Time-Domain Spectrometer Kit for building your own THz Time-Domain Spectrometer 16/06/2016 1 Table of contents 0. Parts for the THz Kit... 3 1. Delay line... 4 2. Pulse generator and lock-in detector... 5 3. THz antennas... 6

More information

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions Difrotec Product & Services Ultra high accuracy interferometry & custom optical solutions Content 1. Overview 2. Interferometer D7 3. Benefits 4. Measurements 5. Specifications 6. Applications 7. Cases

More information

Use of Computer Generated Holograms for Testing Aspheric Optics

Use of Computer Generated Holograms for Testing Aspheric Optics Use of Computer Generated Holograms for Testing Aspheric Optics James H. Burge and James C. Wyant Optical Sciences Center, University of Arizona, Tucson, AZ 85721 http://www.optics.arizona.edu/jcwyant,

More information

Ron Liu OPTI521-Introductory Optomechanical Engineering December 7, 2009

Ron Liu OPTI521-Introductory Optomechanical Engineering December 7, 2009 Synopsis of METHOD AND APPARATUS FOR IMPROVING VISION AND THE RESOLUTION OF RETINAL IMAGES by David R. Williams and Junzhong Liang from the US Patent Number: 5,777,719 issued in July 7, 1998 Ron Liu OPTI521-Introductory

More information

How-to guide. Working with a pre-assembled THz system

How-to guide. Working with a pre-assembled THz system How-to guide 15/06/2016 1 Table of contents 0. Preparation / Basics...3 1. Input beam adjustment...4 2. Working with free space antennas...5 3. Working with fiber-coupled antennas...6 4. Contact details...8

More information

Solution of Exercises Lecture Optical design with Zemax Part 6

Solution of Exercises Lecture Optical design with Zemax Part 6 2013-06-17 Prof. Herbert Gross Friedrich Schiller University Jena Institute of Applied Physics Albert-Einstein-Str 15 07745 Jena Solution of Exercises Lecture Optical design with Zemax Part 6 6 Illumination

More information

Adaptive Optics for LIGO

Adaptive Optics for LIGO Adaptive Optics for LIGO Justin Mansell Ginzton Laboratory LIGO-G990022-39-M Motivation Wavefront Sensor Outline Characterization Enhancements Modeling Projections Adaptive Optics Results Effects of Thermal

More information

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION Revised November 15, 2017 INTRODUCTION The simplest and most commonly described examples of diffraction and interference from two-dimensional apertures

More information

3.0 Alignment Equipment and Diagnostic Tools:

3.0 Alignment Equipment and Diagnostic Tools: 3.0 Alignment Equipment and Diagnostic Tools: Alignment equipment The alignment telescope and its use The laser autostigmatic cube (LACI) interferometer A pin -- and how to find the center of curvature

More information

Development of a Low-order Adaptive Optics System at Udaipur Solar Observatory

Development of a Low-order Adaptive Optics System at Udaipur Solar Observatory J. Astrophys. Astr. (2008) 29, 353 357 Development of a Low-order Adaptive Optics System at Udaipur Solar Observatory A. R. Bayanna, B. Kumar, R. E. Louis, P. Venkatakrishnan & S. K. Mathew Udaipur Solar

More information

Coherent Laser Measurement and Control Beam Diagnostics

Coherent Laser Measurement and Control Beam Diagnostics Coherent Laser Measurement and Control M 2 Propagation Analyzer Measurement and display of CW laser divergence, M 2 (or k) and astigmatism sizes 0.2 mm to 25 mm Wavelengths from 220 nm to 15 µm Determination

More information

CHARA AO Calibration Process

CHARA AO Calibration Process CHARA AO Calibration Process Judit Sturmann CHARA AO Project Overview Phase I. Under way WFS on telescopes used as tip-tilt detector Phase II. Not yet funded WFS and large DM in place of M4 on telescopes

More information

Collimation Tester Instructions

Collimation Tester Instructions Description Use shear-plate collimation testers to examine and adjust the collimation of laser light, or to measure the wavefront curvature and divergence/convergence magnitude of large-radius optical

More information

Information & Instructions

Information & Instructions KEY FEATURES 1. USB 3.0 For the Fastest Transfer Rates Up to 10X faster than regular USB 2.0 connections (also USB 2.0 compatible) 2. High Resolution 4.2 MegaPixels resolution gives accurate profile measurements

More information

Shack-Hartmann wavefront sensor: technical passport

Shack-Hartmann wavefront sensor: technical passport F L E X I B L E Flexible Optical B.V. Adaptive Optics Optical Microsystems Wavefront Sensors O P T I C A L Oleg Soloviev Chief Scientist Röntgenweg 1 2624 BD, Delft The Netherlands Tel: +31 15 285 15-47

More information

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the ECEN 4606 Lab 8 Spectroscopy SUMMARY: ROBLEM 1: Pedrotti 3 12-10. In this lab, you will design, build and test an optical spectrum analyzer and use it for both absorption and emission spectroscopy. The

More information

SpotOptics. The software people for optics OPAL O P A L

SpotOptics. The software people for optics OPAL O P A L Spotptics The software people for optics UTMTED WVEFRNT SENSR ccurate metrology of standard and aspherical lenses (single pass) ccurate metrology of spherical and flat mirrors (double pass) =0.3 to =50

More information

Radial Polarization Converter With LC Driver USER MANUAL

Radial Polarization Converter With LC Driver USER MANUAL ARCoptix Radial Polarization Converter With LC Driver USER MANUAL Arcoptix S.A Ch. Trois-portes 18 2000 Neuchâtel Switzerland Mail: info@arcoptix.com Tel: ++41 32 731 04 66 Principle of the radial polarization

More information

Performance Factors. Technical Assistance. Fundamental Optics

Performance Factors.   Technical Assistance. Fundamental Optics Performance Factors After paraxial formulas have been used to select values for component focal length(s) and diameter(s), the final step is to select actual lenses. As in any engineering problem, this

More information

OPAL. SpotOptics. AUTOMATED WAVEFRONT SENSOR Single and double pass O P A L

OPAL. SpotOptics. AUTOMATED WAVEFRONT SENSOR Single and double pass O P A L Spotptics The software people for optics UTMTED WVEFRNT SENSR Single and double pass ccurate metrology of standard and aspherical lenses ccurate metrology of spherical and flat mirrors =0.3 to =60 mm F/1

More information

Devices & Services Company

Devices & Services Company Devices & Services Company 10290 Monroe Drive, Suite 202 - Dallas, Texas 75229 USA - Tel. 214-902-8337 - Fax 214-902-8303 Web: www.devicesandservices.com Email: sales@devicesandservices.com D&S Technical

More information

How to Properly Select a Laser Power or Energy Sensor

How to Properly Select a Laser Power or Energy Sensor How to Properly Select a Laser Power or Energy Sensor By Dick Rieley, Sales Manager, Mid Altantic and Southeast Regions, Ophir-Spiricon LLC The selection of a sensor to accurately measure the power of

More information

MRO Delay Line. Performance of Beam Compressor for Agilent Laser Head INT-406-VEN The Cambridge Delay Line Team. rev 0.

MRO Delay Line. Performance of Beam Compressor for Agilent Laser Head INT-406-VEN The Cambridge Delay Line Team. rev 0. MRO Delay Line Performance of Beam Compressor for Agilent Laser Head INT-406-VEN-0123 The Cambridge Delay Line Team rev 0.45 1 April 2011 Cavendish Laboratory Madingley Road Cambridge CB3 0HE UK Change

More information

Using Stock Optics. ECE 5616 Curtis

Using Stock Optics. ECE 5616 Curtis Using Stock Optics What shape to use X & Y parameters Please use achromatics Please use camera lens Please use 4F imaging systems Others things Data link Stock Optics Some comments Advantages Time and

More information

Cardinal Points of an Optical System--and Other Basic Facts

Cardinal Points of an Optical System--and Other Basic Facts Cardinal Points of an Optical System--and Other Basic Facts The fundamental feature of any optical system is the aperture stop. Thus, the most fundamental optical system is the pinhole camera. The image

More information

DESIGNING AND IMPLEMENTING AN ADAPTIVE OPTICS SYSTEM FOR THE UH HOKU KE`A OBSERVATORY ABSTRACT

DESIGNING AND IMPLEMENTING AN ADAPTIVE OPTICS SYSTEM FOR THE UH HOKU KE`A OBSERVATORY ABSTRACT DESIGNING AND IMPLEMENTING AN ADAPTIVE OPTICS SYSTEM FOR THE UH HOKU KE`A OBSERVATORY University of Hawai`i at Hilo Alex Hedglen ABSTRACT The presented project is to implement a small adaptive optics system

More information

BEAMAGE KEY FEATURES AVAILABLE MODELS. CMOS Beam Profiling Cameras

BEAMAGE KEY FEATURES AVAILABLE MODELS. CMOS Beam Profiling Cameras BEAM DIAGNOS TICS Beam Profiling Cameras KEY FEATURES SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER SOLUTIONS POWER DETECTORS ENERGY DETECTORS MONITORS AVAILABLE MODELS Beamage-3.0

More information

Lecture 4: Geometrical Optics 2. Optical Systems. Images and Pupils. Rays. Wavefronts. Aberrations. Outline

Lecture 4: Geometrical Optics 2. Optical Systems. Images and Pupils. Rays. Wavefronts. Aberrations. Outline Lecture 4: Geometrical Optics 2 Outline 1 Optical Systems 2 Images and Pupils 3 Rays 4 Wavefronts 5 Aberrations Christoph U. Keller, Leiden University, keller@strw.leidenuniv.nl Lecture 4: Geometrical

More information

Single Slit Diffraction

Single Slit Diffraction PC1142 Physics II Single Slit Diffraction 1 Objectives Investigate the single-slit diffraction pattern produced by monochromatic laser light. Determine the wavelength of the laser light from measurements

More information

Shack-Hartmann wavefront sensor: technical passport

Shack-Hartmann wavefront sensor: technical passport F L E X I B L E Flexible Optical B.V. Adaptive Optics Optical Microsystems Wavefront Sensors O P T I C A L Oleg Soloviev Chief Scientist Röntgenweg 1 2624 BD, Delft The Netherlands Shack-Hartmann wavefront

More information

BEAMAGE-3.0 KEY FEATURES BEAM DIAGNOSTICS AVAILABLE MODELS MAIN FUNCTIONS SEE ALSO ACCESSORIES. CMOS Beam Profiling Cameras

BEAMAGE-3.0 KEY FEATURES BEAM DIAGNOSTICS AVAILABLE MODELS MAIN FUNCTIONS SEE ALSO ACCESSORIES. CMOS Beam Profiling Cameras BEAM DIAGNOSTICS BEAM DIAGNOSTICS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER DETECTORS POWER DETECTORS ENERGY DETECTORS MONITORS CMOS Beam Profiling Cameras AVAILABLE MODELS

More information

White Paper: Modifying Laser Beams No Way Around It, So Here s How

White Paper: Modifying Laser Beams No Way Around It, So Here s How White Paper: Modifying Laser Beams No Way Around It, So Here s How By John McCauley, Product Specialist, Ophir Photonics There are many applications for lasers in the world today with even more on the

More information

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember Günter Toesko - Laserseminar BLZ im Dezember 2009 1 Aberrations An optical aberration is a distortion in the image formed by an optical system compared to the original. It can arise for a number of reasons

More information

Tolerancing in Zemax. Lecture 4

Tolerancing in Zemax. Lecture 4 Tolerancing in Zemax Lecture 4 Objectives: Lecture 4 At the end of this lecture you should: 1. Understand the reason for tolerancing and its relation to typical manufacturing errors 2. Be able to perform

More information

Industrial quality control HASO for ensuring the quality of NIR optical components

Industrial quality control HASO for ensuring the quality of NIR optical components Industrial quality control HASO for ensuring the quality of NIR optical components In the sector of industrial detection, the ability to massproduce reliable, high-quality optical components is synonymous

More information

PHY 431 Homework Set #5 Due Nov. 20 at the start of class

PHY 431 Homework Set #5 Due Nov. 20 at the start of class PHY 431 Homework Set #5 Due Nov. 0 at the start of class 1) Newton s rings (10%) The radius of curvature of the convex surface of a plano-convex lens is 30 cm. The lens is placed with its convex side down

More information

ERS KEY FEATURES BEAM DIAGNOSTICS MAIN FUNCTIONS AVAILABLE MODEL. CMOS Beam Profiling Camera. 1 USB 3.0 for the Fastest Transfer Rates

ERS KEY FEATURES BEAM DIAGNOSTICS MAIN FUNCTIONS AVAILABLE MODEL. CMOS Beam Profiling Camera. 1 USB 3.0 for the Fastest Transfer Rates POWER DETECTORS ENERGY DETECTORS MONITORS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER DETECTORS CAMERA PROFIL- CMOS Beam Profiling Camera KEY FEATURES ERS 1 USB 3.0 for the

More information

Lens Design I. Lecture 5: Advanced handling I Herbert Gross. Summer term

Lens Design I. Lecture 5: Advanced handling I Herbert Gross. Summer term Lens Design I Lecture 5: Advanced handling I 2018-05-17 Herbert Gross Summer term 2018 www.iap.uni-jena.de 2 Preliminary Schedule - Lens Design I 2018 1 12.04. Basics 2 19.04. Properties of optical systems

More information

The Design, Fabrication, and Application of Diamond Machined Null Lenses for Testing Generalized Aspheric Surfaces

The Design, Fabrication, and Application of Diamond Machined Null Lenses for Testing Generalized Aspheric Surfaces The Design, Fabrication, and Application of Diamond Machined Null Lenses for Testing Generalized Aspheric Surfaces James T. McCann OFC - Diamond Turning Division 69T Island Street, Keene New Hampshire

More information

Instructions for the Experiment

Instructions for the Experiment Instructions for the Experiment Excitonic States in Atomically Thin Semiconductors 1. Introduction Alongside with electrical measurements, optical measurements are an indispensable tool for the study of

More information

1.1 Singlet. Solution. a) Starting setup: The two radii and the image distance is chosen as variable.

1.1 Singlet. Solution. a) Starting setup: The two radii and the image distance is chosen as variable. 1 1.1 Singlet Optimize a single lens with the data λ = 546.07 nm, object in the distance 100 mm from the lens on axis only, focal length f = 45 mm and numerical aperture NA = 0.07 in the object space.

More information

Agilent 10717A Wavelength Tracker

Agilent 10717A Wavelength Tracker 7I Agilent 10717A Wavelength Tracker MADE Description Description The Agilent 10717A Wavelength Tracker (see Figure 7I-1) uses one axis of a laser measurement system to report wavelength-of-light changes,

More information

Computer Generated Holograms for Optical Testing

Computer Generated Holograms for Optical Testing Computer Generated Holograms for Optical Testing Dr. Jim Burge Associate Professor Optical Sciences and Astronomy University of Arizona jburge@optics.arizona.edu 520-621-8182 Computer Generated Holograms

More information

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit Experiment 1: Fraunhofer Diffraction of Light by a Single Slit Purpose 1. To understand the theory of Fraunhofer diffraction of light at a single slit and at a circular aperture; 2. To learn how to measure

More information

Ocular Shack-Hartmann sensor resolution. Dan Neal Dan Topa James Copland

Ocular Shack-Hartmann sensor resolution. Dan Neal Dan Topa James Copland Ocular Shack-Hartmann sensor resolution Dan Neal Dan Topa James Copland Outline Introduction Shack-Hartmann wavefront sensors Performance parameters Reconstructors Resolution effects Spot degradation Accuracy

More information

PROCEEDINGS OF SPIE. Measurement of low-order aberrations with an autostigmatic microscope

PROCEEDINGS OF SPIE. Measurement of low-order aberrations with an autostigmatic microscope PROCEEDINGS OF SPIE SPIEDigitalLibrary.org/conference-proceedings-of-spie Measurement of low-order aberrations with an autostigmatic microscope William P. Kuhn Measurement of low-order aberrations with

More information

Typical Interferometer Setups

Typical Interferometer Setups ZYGO s Guide to Typical Interferometer Setups Surfaces Windows Lens Systems Distribution in the UK & Ireland www.lambdaphoto.co.uk Contents Surface Flatness 1 Plano Transmitted Wavefront 1 Parallelism

More information

Lecture 2: Geometrical Optics. Geometrical Approximation. Lenses. Mirrors. Optical Systems. Images and Pupils. Aberrations.

Lecture 2: Geometrical Optics. Geometrical Approximation. Lenses. Mirrors. Optical Systems. Images and Pupils. Aberrations. Lecture 2: Geometrical Optics Outline 1 Geometrical Approximation 2 Lenses 3 Mirrors 4 Optical Systems 5 Images and Pupils 6 Aberrations Christoph U. Keller, Leiden Observatory, keller@strw.leidenuniv.nl

More information

Testing Aspheric Lenses: New Approaches

Testing Aspheric Lenses: New Approaches Nasrin Ghanbari OPTI 521 - Synopsis of a published Paper November 5, 2012 Testing Aspheric Lenses: New Approaches by W. Osten, B. D orband, E. Garbusi, Ch. Pruss, and L. Seifert Published in 2010 Introduction

More information

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY References: http://virlab.virginia.edu/vl/home.htm (University of Virginia virtual lab. Click on the AFM link) An atomic force

More information

High contrast imaging lab

High contrast imaging lab High contrast imaging lab Ay122a, November 2016, D. Mawet Introduction This lab is an introduction to high contrast imaging, and in particular coronagraphy and its interaction with adaptive optics sytems.

More information

Chapter Ray and Wave Optics

Chapter Ray and Wave Optics 109 Chapter Ray and Wave Optics 1. An astronomical telescope has a large aperture to [2002] reduce spherical aberration have high resolution increase span of observation have low dispersion. 2. If two

More information

COLLIMATORS AND FOCUSERS RECEPTACLE STYLE

COLLIMATORS AND FOCUSERS RECEPTACLE STYLE COLLIMATORS AND FOCUSERS RECEPTACLE STYLE FEATURES: High power handling Rugged and compact design Low insertion loss Wide wavelength range 200-2100 nm Wide range of beam diameters GRIN, aspheric, achromatic,

More information

PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry

PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry Purpose PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry In this experiment, you will study the principles and applications of interferometry. Equipment and components PASCO

More information

EUV Plasma Source with IR Power Recycling

EUV Plasma Source with IR Power Recycling 1 EUV Plasma Source with IR Power Recycling Kenneth C. Johnson kjinnovation@earthlink.net 1/6/2016 (first revision) Abstract Laser power requirements for an EUV laser-produced plasma source can be reduced

More information

Lens Design I. Lecture 3: Properties of optical systems II Herbert Gross. Summer term

Lens Design I. Lecture 3: Properties of optical systems II Herbert Gross. Summer term Lens Design I Lecture 3: Properties of optical systems II 205-04-8 Herbert Gross Summer term 206 www.iap.uni-jena.de 2 Preliminary Schedule 04.04. Basics 2.04. Properties of optical systrems I 3 8.04.

More information

Lecture 2: Geometrical Optics. Geometrical Approximation. Lenses. Mirrors. Optical Systems. Images and Pupils. Aberrations.

Lecture 2: Geometrical Optics. Geometrical Approximation. Lenses. Mirrors. Optical Systems. Images and Pupils. Aberrations. Lecture 2: Geometrical Optics Outline 1 Geometrical Approximation 2 Lenses 3 Mirrors 4 Optical Systems 5 Images and Pupils 6 Aberrations Christoph U. Keller, Leiden Observatory, keller@strw.leidenuniv.nl

More information

Technical Note How to Compensate Lateral Chromatic Aberration

Technical Note How to Compensate Lateral Chromatic Aberration Lateral Chromatic Aberration Compensation Function: In JAI color line scan cameras (3CCD/4CCD/3CMOS/4CMOS), sensors and prisms are precisely fabricated. On the other hand, the lens mounts of the cameras

More information

CONFOCAL MICROSCOPE CM-1

CONFOCAL MICROSCOPE CM-1 CONFOCAL MICROSCOPE CM-1 USER INSTRUCTIONS Scientific Instruments Dr. J.R. Sandercock Im Grindel 6 Phone: +41 44 776 33 66 Fax: +41 44 776 33 65 E-Mail: info@jrs-si.ch Internet: www.jrs-si.ch 1. Properties

More information

Optical Design with Zemax

Optical Design with Zemax Optical Design with Zemax Lecture : Correction II 3--9 Herbert Gross Summer term www.iap.uni-jena.de Correction II Preliminary time schedule 6.. Introduction Introduction, Zemax interface, menues, file

More information

Infra Red Interferometers

Infra Red Interferometers Infra Red Interferometers for performance testing of infra-red materials and optical systems Specialist expertise in testing, analysis, design, development and manufacturing for Optical fabrication, Optical

More information

Spectroscopy of Ruby Fluorescence Physics Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018

Spectroscopy of Ruby Fluorescence Physics Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018 1 Spectroscopy of Ruby Fluorescence Physics 3600 - Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018 I. INTRODUCTION The laser was invented in May 1960 by Theodor Maiman.

More information

Beamscope-P8 Wavelength Range. Resolution ¼ - 45 ¼ - 45

Beamscope-P8 Wavelength Range. Resolution ¼ - 45 ¼ - 45 Scanning Slit System Beamscope-P8 Typical Applications: Laser / diode laser characterisation Laser assembly development, alignment, characterisation, production test & QA. Lasers and laser assemblies for

More information

AG Optical Systems. Newtonian Astrograph Manual Version AG Optical Systems

AG Optical Systems. Newtonian Astrograph Manual Version AG Optical Systems AG Optical Systems Newtonian Astrograph Manual Version 2 2012 Table of Contents 1. Introduction 2. System Specifications 3. Initial Assembly 4. Collimation 5. Care and Cleaning 6. Cooling Fan Operation

More information

OPTINO. SpotOptics VERSATILE WAVEFRONT SENSOR O P T I N O

OPTINO. SpotOptics VERSATILE WAVEFRONT SENSOR O P T I N O Spotptics he software people for optics VERSALE WAVEFR SESR Accurate metrology in single and double pass Lenses, mirrors and laser beams Any focal length and diameter Large dynamic range Adaptable for

More information

Exercises Advanced Optical Design Part 5 Solutions

Exercises Advanced Optical Design Part 5 Solutions 2014-12-09 Manuel Tessmer M.Tessmer@uni-jena.dee Minyi Zhong minyi.zhong@uni-jena.de Herbert Gross herbert.gross@uni-jena.de Friedrich Schiller University Jena Institute of Applied Physics Albert-Einstein-Str.

More information

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790 Calibration Standard for Sighting & Imaging Devices 2223 West San Bernardino Road West Covina, California 91790 Phone: (626) 962-5181 Fax: (626) 962-5188 www.davidsonoptronics.com sales@davidsonoptronics.com

More information

RPMSP Series Installation Guide

RPMSP Series Installation Guide RPMSP Series Installation Guide Contents 1. Overview... page 1 2. Unpacking the Projector...2 3. Projector Configuration...2 4. Projector Throw Distance and Mounting...9 5. Projection Lens Focus...9 6.

More information

Beam Analysis BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers. Disruptive Technology

Beam Analysis BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers. Disruptive Technology 3.8 BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers Instantly measure focus spot size Dynamically measure focal plane location during start-up From

More information

IBIL setup operation manual for SynerJY software version

IBIL setup operation manual for SynerJY software version IBIL setup operation manual for SynerJY software version 1.8.5.0 Manual version 1.0, 31/10/2008 Author: Carlos Marques Equipment Managers: Carlos Marques, +351219946084, cmarques@itn.pt Luís Alves, +351219946112,

More information

1.6 Beam Wander vs. Image Jitter

1.6 Beam Wander vs. Image Jitter 8 Chapter 1 1.6 Beam Wander vs. Image Jitter It is common at this point to look at beam wander and image jitter and ask what differentiates them. Consider a cooperative optical communication system that

More information

ADALAM Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing D2.2. Ger Folkersma (Demcon)

ADALAM Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing D2.2. Ger Folkersma (Demcon) D2.2 Automatic adjustable reference path system Document Coordinator: Contributors: Dissemination: Keywords: Ger Folkersma (Demcon) Ger Folkersma, Kevin Voss, Marvin Klein (Demcon) Public Reference path,

More information

Lenses Design Basics. Introduction. RONAR-SMITH Laser Optics. Optics for Medical. System. Laser. Semiconductor Spectroscopy.

Lenses Design Basics. Introduction. RONAR-SMITH Laser Optics. Optics for Medical. System. Laser. Semiconductor Spectroscopy. Introduction Optics Application Lenses Design Basics a) Convex lenses Convex lenses are optical imaging components with positive focus length. After going through the convex lens, parallel beam of light

More information

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002 1051-232 Imaging Systems Laboratory II Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002 Abstract. In the last lab, you saw that coherent light from two different locations

More information

ENSC 470/894 Lab 3 Version 6.0 (Nov. 19, 2015)

ENSC 470/894 Lab 3 Version 6.0 (Nov. 19, 2015) ENSC 470/894 Lab 3 Version 6.0 (Nov. 19, 2015) Purpose The purpose of the lab is (i) To measure the spot size and profile of the He-Ne laser beam and a laser pointer laser beam. (ii) To create a beam expander

More information

GENERALISED PHASE DIVERSITY WAVEFRONT SENSING 1 ABSTRACT 1. INTRODUCTION

GENERALISED PHASE DIVERSITY WAVEFRONT SENSING 1 ABSTRACT 1. INTRODUCTION GENERALISED PHASE DIVERSITY WAVEFRONT SENSING 1 Heather I. Campbell Sijiong Zhang Aurelie Brun 2 Alan H. Greenaway Heriot-Watt University, School of Engineering and Physical Sciences, Edinburgh EH14 4AS

More information

ECEN 4606, UNDERGRADUATE OPTICS LAB

ECEN 4606, UNDERGRADUATE OPTICS LAB ECEN 4606, UNDERGRADUATE OPTICS LAB Lab 2: Imaging 1 the Telescope Original Version: Prof. McLeod SUMMARY: In this lab you will become familiar with the use of one or more lenses to create images of distant

More information

Beam Shaping and Simultaneous Exposure by Diffractive Optical Element in Laser Plastic Welding

Beam Shaping and Simultaneous Exposure by Diffractive Optical Element in Laser Plastic Welding Beam Shaping and Simultaneous Exposure by Diffractive Optical Element in Laser Plastic Welding AKL`12 9th May 2012 Dr. Daniel Vogler Page 1 Motivation: Quality and flexibility diffractive spot shaping

More information

MASSACHUSETTS INSTITUTE OF TECHNOLOGY. 2.71/2.710 Optics Spring 14 Practice Problems Posted May 11, 2014

MASSACHUSETTS INSTITUTE OF TECHNOLOGY. 2.71/2.710 Optics Spring 14 Practice Problems Posted May 11, 2014 MASSACHUSETTS INSTITUTE OF TECHNOLOGY 2.71/2.710 Optics Spring 14 Practice Problems Posted May 11, 2014 1. (Pedrotti 13-21) A glass plate is sprayed with uniform opaque particles. When a distant point

More information

Beam Profiling. Introduction. What is Beam Profiling? by Michael Scaggs. Haas Laser Technologies, Inc.

Beam Profiling. Introduction. What is Beam Profiling? by Michael Scaggs. Haas Laser Technologies, Inc. Beam Profiling by Michael Scaggs Haas Laser Technologies, Inc. Introduction Lasers are ubiquitous in industry today. Carbon Dioxide, Nd:YAG, Excimer and Fiber lasers are used in many industries and a myriad

More information

A fast F-number 10.6-micron interferometer arm for transmitted wavefront measurement of optical domes

A fast F-number 10.6-micron interferometer arm for transmitted wavefront measurement of optical domes A fast F-number 10.6-micron interferometer arm for transmitted wavefront measurement of optical domes Doug S. Peterson, Tom E. Fenton, Teddi A. von Der Ahe * Exotic Electro-Optics, Inc., 36570 Briggs Road,

More information

ABSTRACT 1. INTRODUCTION

ABSTRACT 1. INTRODUCTION Design and performance of a new compact adaptable autostigmatic alignment tool William P. Kuhn Opt-E, 3450 S Broadmont Dr Ste 112, Tucson, AZ, USA 85713-5245 bill.kuhn@opt-e.com ABSTRACT The design and

More information

Technical Explanation for Displacement Sensors and Measurement Sensors

Technical Explanation for Displacement Sensors and Measurement Sensors Technical Explanation for Sensors and Measurement Sensors CSM_e_LineWidth_TG_E_2_1 Introduction What Is a Sensor? A Sensor is a device that measures the distance between the sensor and an object by detecting

More information

Wavefront sensing by an aperiodic diffractive microlens array

Wavefront sensing by an aperiodic diffractive microlens array Wavefront sensing by an aperiodic diffractive microlens array Lars Seifert a, Thomas Ruppel, Tobias Haist, and Wolfgang Osten a Institut für Technische Optik, Universität Stuttgart, Pfaffenwaldring 9,

More information

Optical design of a high resolution vision lens

Optical design of a high resolution vision lens Optical design of a high resolution vision lens Paul Claassen, optical designer, paul.claassen@sioux.eu Marnix Tas, optical specialist, marnix.tas@sioux.eu Prof L.Beckmann, l.beckmann@hccnet.nl Summary:

More information

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name: EE119 Introduction to Optical Engineering Fall 2009 Final Exam Name: SID: CLOSED BOOK. THREE 8 1/2 X 11 SHEETS OF NOTES, AND SCIENTIFIC POCKET CALCULATOR PERMITTED. TIME ALLOTTED: 180 MINUTES Fundamental

More information

Tutorial Zemax 9: Physical optical modelling I

Tutorial Zemax 9: Physical optical modelling I Tutorial Zemax 9: Physical optical modelling I 2012-11-04 9 Physical optical modelling I 1 9.1 Gaussian Beams... 1 9.2 Physical Beam Propagation... 3 9.3 Polarization... 7 9.4 Polarization II... 11 9 Physical

More information