Lufft UMB Sensor Overview

Size: px
Start display at page:

Download "Lufft UMB Sensor Overview"

Transcription

1 Lufft Sensor Overview Wind Radiance (solar radiation) Titan Ventus WS310 Platinum WS301/303 Gold V200A WS300 WS400 WS304 Professional WS200 WS401 WS302

2 Radiance (solar radiation) Radiation 2 Channel EPANDER Protocols WS510 WS501/503 WS500 WS504 WS600 WS700 WS502 WS601

3 Lufft s high-quality networks for measuring emissions consist of gas measurements, dust particle measurements, as well as meteorological measurements. UPrecision with The WS product family deliver all meteorological measured data for Lufft s high-quality measuring networks. By means of the digital interface, they can be perfectly integrated into the measured data architecture of the entire system. When it comes to road traffi c meteorology ( Green ITS ), quality is playing a more and more important role: In the future, traffi c guidance and air pollution will depend on each other. This can only be realized with precise measured data, especially in large cities. Source: Dr. Holger Gerwig Umweltbundesamt Langen

4 Lufft WS601-, Relative Humidity,, Air Pressure, Wind, Electronic Compass From the WS product family of professional intelligent measurement transducers with digital interface for environmental applications. Integrated design with ventilated radiation protection for measuring: - Air temperature - Relative humidity Relative humidity is measured by means of a capacitive sensor element; a precision NTC measuring element is used to measure air temperature. is measured by a tipping spoon and tipping bucket processes. The lexible tipping bucket allows a 0.2mm or a 0.5mm resolution of the rainfall. Optionally, the WS601- can be equipped with a leaf wetness sensor in addition. Ultrasonic sensor technology is used to take wind measurements. Measurement output can be accessed by the following protocolls: -Binary, -, SDI-12, One external temperature sensor is connectable. Lufft WS601- Smart Weather Sensor Order No. WS U01 Technical Data Dimensions Ø approx. 164 mm, height approx. 445 mm Weight Approx. 1.7kg Principle NTC Measuring range C ± 0.2 C ( 20 C +50 C), otherwise ± 0.5 C ( > 30 C) Relative humidity Principle Capacitive Measuring range 0 100% RH ± 2% RH Resolution 0.2mm ± 2% Max. intensity 144mm/h (with Resolution 0.5mm reduction ring) ± 2% Max. intensity 360mm/h Principle MEMS capacitive Measuring range hPa ± 0.5hPa ( C) Principle Ultrasonic Measuring range <3 RMSE >1.0m/s Principle Ultrasonic Measuring range 0 30m/s ± 0.3m/s or 3% RMS General Heating 20VA at 24VDC Information Protection type housing IP66 Interface RS485, 2-wire, half-duplex Op. power consumption VDC Operating humidity range 0 100% Op. temperature range C Accessories Surge protection 8379.USP Power supply 24V/4A 8366.USV1 Interface converter ISOCON UISO Digital-analog-converter DACON UDAC Leaf wetness sensor WLW Sensor WT WT1 Road Surface Sensor WST WST1 Connection cable, 20m 8370.UKAB20 All in One Aspirated temperature/humidity measurement Open communication protocol: Binary - SDI Analoge outputs in combination with 8160.UDAC

5 Standard Certificate for all -Sensors LUFFT Mess- und Seite/Page: 1/2 Regeltechnik GmbH Herstellerprüfzertifikat M nach DIN Manufacturer test certificate M according to DIN Gegenstand Object Sensornummer Sensor number Hersteller Manufacturer IRS31- Seriennummer Serial number G. Lufft Mess- und Regeltechnik GmbH Gutenbergstraße Fellbach, Germany Temperaturmessung / measurement Fahrbahnoberflächentemperatur Road surface temperature Tiefentemperatur 1 under ground 1 Tiefentemperatur 2 under ground 2 = 0,0 C ±0,1 C = 0,0 C ±0,1 C = 0,0 C ±0,1 C Yes No Temperatursensor / sensor Fahrbahnoberflächensensor Road surface sensor Tiefentemperatursensor 1 sensor under ground 1 Tiefentemperatursensor 2 sensor under ground 2 Dieses Prüfzertifikat darf nur vollständig und unverändert weiterverbreitet werden. Auszüge oder Änderungen bedürfen der Genehmigung des Ausstellers. Prüfzertifikate ohne Unterschrift und Stempel haben keine Gültigkeit. This test certificate may not be reproduced other than in full except with the permission of the exhibiting company. Seriennummer / Serial number: Test certificates without signature and seal are not valid. Stempel Datum Qualitätssicherung Bearbeiter Kalibrierung Gefriertemperatur / Calibration freezing point Seal Date Quality control Person in charge i. V. Rolf Großmann = 0,0 C ±0,1 C = 0,0 C ±0,1 C = 0,0 C ±0,1 C Yes No LUFFT Mess- und Seite/Page: 2/2 Regeltechnik GmbH Herstellerprüfzertifikat M nach DIN Manufacturer test certificate M according to DIN Wasserfilmhöhe water film height Gefriertemperatur freezing point Sollwert reference value Messwert reading H2O + NaCl 11,8 %, 1000 µm -8,9 C ± 1 C 11,8 % ± 1,0 % % H2O + NaCl 2,0 %, 500 µm -1,0 C ± 1 C 2,0 % ± 1,0 % % H2O + NaCl 1,1 %, 250 µm -0,6 C ± 1 C 1,1 % ± 1,0 % % Kalibrierung Wasserfilmhöhe / Calibration water film height 6000 Wfh Messwert / Wfh reading [µm] Wfh Sollwert / Wfh reference value [µm ] Funktionstest / Function test Temperaturzyklus von 30 C +70 C cycle from 30 C C Alle Messwerte korrekt All measured values correctly Yes No

Lufft UMB Sensor Overview

Lufft UMB Sensor Overview Lufft Sensor Overview Wind Radiance (solar radiation) Titan Ventus WS310 Platinum WS301/303 Gold V200A WS300 WS400 WS304 Professional WS200 WS401 WS302 Radiance (solar radiation) Radiation 2 Channel EPANDER

More information

Lufft UMB Sensor Overview

Lufft UMB Sensor Overview Lufft Sensor Overview Wind Radiance (solar radiation) Titan Ventus WS310 Platinum WS301/303 Gold V200A WS300 WS400 WS304 Professional WS200 WS401 WS302 Radiance (solar radiation) Radiation 2 Channel EPANDER

More information

Lufft UMB Sensor Overview

Lufft UMB Sensor Overview Lufft Sensor Overview Wind Radiance (solar radiation) Titan Ventus WS310 Platinum WS301/303 Gold V200A WS300 WS400 WS304 Professional WS200 WS401 WS302 Radiance (solar radiation) Radiation 2 Channel EPANDER

More information

UMB-Technology. A Passion for Precision.

UMB-Technology. A Passion for Precision. UMB-Technology A Passion for Precision a passion for precision passion pour la précision pasión por la precisión passione per la precisione a pa www.umb-technology.info Compact design Easy commissioning

More information

UMB-Technology. A Passion for Precision

UMB-Technology.  A Passion for Precision UMB-Technology A Passion for Precision a passion for precision passion pour la précision pasión por la precisión passione per la precisione a pa www.umb-technology.info Compact design Easy commissioning

More information

Capacitive Coupling Clamp CDN 2012

Capacitive Coupling Clamp CDN 2012 Capacitive Coupling Clamp CDN 2012 Coupling clamp for automotive electronics Conforms to ISO 7637-3 Pulse injection on signal and control lines The coupling clamp CDN 2012 conforms exactly to the requirements

More information

User Manual Smart Weather Sensors

User Manual Smart Weather Sensors User Manual s WS800-UMB WS700-UMB WS600-UMB / WS601-UMB WS501-UMB / WS502-UMB / WS503-UMB / WS504-UMB WS510-UMB WS500-UMB WS400-UMB / WS401-UMB WS301-UMB / WS302-UMB / WS303-UMB / WS304-UMB WS310-UMB WS300-UMB

More information

Intelligent Road Sensor IRS31Pro-UMB

Intelligent Road Sensor IRS31Pro-UMB English Intelligent Road Sensor IRS31Pro-UMB VERSION 2 (01/2014) Please read this operating manual completely before commissioning the equipment. www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach,

More information

Operating Manual. English. Wind Meter V200A-UMB.

Operating Manual. English. Wind Meter V200A-UMB. English Wind Meter V200A-UMB www.lufft.com G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to make technical changes without notice. Contents 1 Please Read Before Use... 5

More information

G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. Subject to change without notice.

G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. Subject to change without notice. G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. Subject to change without notice. Operating Manual IRS31Pro-UMB English G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. Subject to change

More information

Operating Manual Non Invasive Road Sensor NIRS31-UMB English

Operating Manual Non Invasive Road Sensor NIRS31-UMB English English NIRS31-UMB Please read this Operating Manual in its entirety before commissioning the equipment. www.lufft.com G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. Subject to change without

More information

Introduction. Applications

Introduction. Applications Introduction In meteorology, the precision of measurement data parameters is critical for accurate weather forecasting and environmental research. ROTRONIC meteorological probes have an excellent reputation

More information

ventus Operating Manual Operating Manual English Wind Meter V200A-UMB G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1

ventus Operating Manual Operating Manual English Wind Meter V200A-UMB   G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 English Wind Meter V200A-UMB www.lufft.com G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 2 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany Contents 1 Please Read Before Use... 5 1.1

More information

D Series Sensors for Humidity and Temperature Measurement Type DI Room version Optional display Technical data Humidity

D Series Sensors for Humidity and Temperature Measurement Type DI Room version Optional display Technical data Humidity Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH D-75 Bondorf. Germany D-07987 Mohlsdorf-Teichwolframsdorf. Germany Tel. +9 (0)757-95-0. Fax +9 (0)757-758 Tel. +9(0)66-670-0. Fax +9(0)66-670-0

More information

Operating Manual ARS31-UMB

Operating Manual ARS31-UMB Active Road Sensor Order No.: 8610.U050 50m cable Status V2 (02/2010) www.lufft.com Contents 1 Please read before commissioning... 3 1.1 Symbols used... 3 1.2 Safety instructions... 3 1.3 Designated use...

More information

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs European Electronic Controls Catalogue Catalogue Section A Product Bulletin TS-9100 Issue Date 09 2000 TS-9100 Electronic Sensors and Transducers I ntroduction The TS-9100 series of electronic temperature

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ELECTRONIC COMPASS W/ SERIAL INTERFACE MODEL 32500 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772

More information

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH D-71145 Bondorf. Germany D-07987 Mohlsdorf-Teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0. Fax +49 (0)7457-3758 Tel. +49(0)3661-62704-0.

More information

Room Sensors. for relative humidity and temperature

Room Sensors. for relative humidity and temperature 1 857 1857P01 Room Sensors for relative humidity and temperature QFA20 Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V for relative humidity Signal output DC 010 V or LG-Ni 1000 or T1 for

More information

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range 1 857 1857P01 Room Sensors for relative humidity and temperature QFA20 Use Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V for relative humidity Signal output DC 010 V or LG-Ni 1000 or T1

More information

Differential pressure sensors

Differential pressure sensors 1 912 1912P02 QBM64/ 1912P01 QBM63/ Differential pressure sensors for air and non-aggressive gases, with a diaphragm sensing element QBM63/ QBM64/ With choice of pressure-linear or extracting-the-root

More information

NEW TOUGHEST WIND SENSORS THE WORLD S 1:2

NEW TOUGHEST WIND SENSORS THE WORLD S  1:2 F T 74 2 D ATA S H E E T NEW S U R FA C E M O U N T D E S I G N E D F O R I N T E G R AT I O N THE WORLD S TOUGHEST WIND SENSORS WWW.FTTECHNOLOGIES.COM 1:2 PROVEN IT LOOKS DIFFERENT BECAUSE IT IS DIFFERENT

More information

Industrial Measuring Devices

Industrial Measuring Devices Industrial Measuring Devices A Passion for Precision por la precisión passione per la precisione a passion for precision passion pour la précision pasión por www.lufft.com The highly demanding and complex

More information

NC Joining Module NCFB

NC Joining Module NCFB NC Joining System NC Joining Module NCF with Cost Optimized Standard Design The joining module Type 210A (in two size available) with integral piezoelectric force sensor and measuring ranges of 5... 50

More information

DTM.OCS.S/N - Modbus Level Transmitter

DTM.OCS.S/N - Modbus Level Transmitter Digital Submersible Level Transmitter with Modbus Interface DTM.OCS.S/N - Modbus Level Transmitter CUSTOMER BENEFITS High precision digital level transmitter with standard Modbus interface Fast customization

More information

Type EXT with cable, probe sold

Type EXT with cable, probe sold standard signal FF-GLT-Series Description Type INT for duct mounting, probe installed Type EXT with cable, probe sold Type AF for wall mounting, probe sold Characteristic features Standard signal 0...

More information

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information *09005137* BA_EN_DE50 Rev.A 11/12 *09005137* d e v e l o p i n g s o l u t i o n s DE50 Operating Manual Differential pressure transmitter Table of Contents 1 Safety guidelines 2 Application purpose 3

More information

Combi sensor C B1. A: Wind wheel. west, east, south C: Dawn sensor D: Rain sensor. Ref.-No. with DCF77 receiver WS 10 KSDCF (No KNX device)

Combi sensor C B1. A: Wind wheel. west, east, south C: Dawn sensor D: Rain sensor. Ref.-No. with DCF77 receiver WS 10 KSDCF (No KNX device) Combi sensor A B D C B B A: Wind wheel B... B: Brightness sensors west, east, south C: Dawn sensor D: Rain sensor Combi sensor WS 0 KS with DCF77 receiver WS 0 KSDCF The combi sensor serves for the measurement

More information

Temperature Sensor Tri-Clamp

Temperature Sensor Tri-Clamp SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-47P, -67P, -167P PHARMA Temperature Sensor Tri-Clamp Application/Specified usage Temperature Measurement in vessels and pipes Authorizations Application

More information

Technical Specification Temperature-Humidity-Pressure Sensor

Technical Specification Temperature-Humidity-Pressure Sensor Technical Specification ITEM CODE RELEASE DATE AUTHOR B80951-01 24 th October 2017 T. Thiesing REVISION REVISION DATE VERSION AUTHOR B-COMMAND GmbH Gruetzmuehlenweg 46 22339 Hamburg Germany FON: +49 40

More information

Lexium integrated drives

Lexium integrated drives Description ILp for CANopen, PROFIBUS DP, RS ILA with AC synchronous servo motor Description ILA comprise control electronics with a fieldbus interface for CANopen DS, PROFIBUS DP or RS and an AC synchronous

More information

OPUS20 Multiple Functions with Internal Sensors

OPUS20 Multiple Functions with Internal Sensors Measurement OPUS20 Multiple Functions with Internal Sensors Functions THI 8120.00 THIP 8120.10 TCO 8120.20 Power supply battery Power supply USB Power supply LAN (POE) optional optional optional Measured

More information

VACUUM METROLOGY VAKUUM-MESSTECHNIK

VACUUM METROLOGY VAKUUM-MESSTECHNIK VACUUM METROLOGY V a c u u m I n s t r u m e n t s VAKUUM-MESSTECHNIK T H Y R A C O N T A B O U T U S We measure Nothing, yet accurately Precision is a matter of course in terms of our measuring instruments

More information

Wind Direction Transmitter First Class analogue output x0.1xx

Wind Direction Transmitter First Class analogue output x0.1xx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021514/03/09 Wind Direction Transmitter First Class analogue output 4.3150.x0.1xx ADOLF THIES GmbH

More information

Operating Manual ARS31Pro-UMB ARS31-UMB

Operating Manual ARS31Pro-UMB ARS31-UMB Operating Manual ARS31Pro-UMB ARS31-UMB Active Road Sensor Order No. ARS31Pro-UMB: Order No. ARS31-UMB: 8810.U051 50m cable 8610.U050 50m cable Version V6 (06/2014) Operating Manual ARS31Pro-UMB English

More information

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021488/06/09 Wind Direction Transmitter - compact - GMR, analogue output - 4.3129.60.xxx 4.3129.80.xxx

More information

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks Threshold value monitoring Pulse outputs UMG 96L / UMG 96 Universal measurement device Measuring accuracy Energy: Class 2 Current.../1 A,.../5 A Voltage L - N: ± 1 % Networks TN-, TT-Networks 2 digital

More information

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator ANSI version Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam

More information

High Tone Power Therapy Device. HiToP 181-H. Service manual for the patient device. gbo Medizintechnik AG 2004 Version 1.3

High Tone Power Therapy Device. HiToP 181-H. Service manual for the patient device. gbo Medizintechnik AG 2004 Version 1.3 High Tone Power Therapy Device HiToP 181-H Service manual for the patient device HiToP 181-H 2 Das vorliegende Handbuch wurde von der gbo Medizintechnik AG erstellt und auf seine Richtigkeit überprüft.

More information

UMG 103-CBM. Universal measurement device for DIN rails

UMG 103-CBM. Universal measurement device for DIN rails Universal measurement device for DIN rails Harmonics GridVis Analysis software Modbus interface Measurement accuracy 0.5 Communication Protocols: Modbus RTU / Slave Interface RS485 Accuracy of measurement

More information

Test Report No.: Prüfbericht - Nr.:

Test Report No.: Prüfbericht - Nr.: Products Produkte Test Report No.: Prüfbericht - Nr.: 50114588 001 Client: Auftraggeber: Test item: Gegenstand der Prüfung: Tortech Pty Ltd. 4/31 Wentworth St., Greenacre NSW, Australia. 3 kva isolation

More information

Wind Transmitter First Class

Wind Transmitter First Class THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021310/07/06 Wind Transmitter First Class 4.3350.00.000 4.3350.10.000 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Hygro-ThermoTransmitter-compact xxx

Hygro-ThermoTransmitter-compact xxx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 020891/08/07 Hygro-ThermoTransmitter-compact 1.1005.54.xxx 1.1005.54.000/150/161/461/173 1.1005.54.241/441

More information

Ultrasonic level measuring device, non-contact

Ultrasonic level measuring device, non-contact Ultrasonic level measuring device, non-contact For level measurement up to 8 m 4... 20 ma/hart - 2 wires Suitable for solids ATEX approvals Type 8177 can be combined with... Type 8611 Type 8793 Type 8802-GB

More information

HD48V01T HD48V17T HD48V77T. [ GB ] Temperature, Relative humidity and Dew Point transmitters

HD48V01T HD48V17T HD48V77T. [ GB ] Temperature, Relative humidity and Dew Point transmitters H4801T H48V01T H4817T H48V17T H4877T H48V77T [ GB ] Temperature, Relative humidity and ew Point transmitters [ GB ] [ GB ] escription H48.. series of transmitters measure temperature, relative humidity

More information

LINAX 4000L Continuous-line recorder

LINAX 4000L Continuous-line recorder -48-852-0 4/2.99 1 to 4 line channels Format 144 mm x 144 mm, mounting depth 250 mm Combined recording table for roll chart (2 m) or fanfold chart (16 m) Measuring channels electrically isolated Rugged

More information

Wind Direction Transmitter - compact - GMR, analogue output xxx

Wind Direction Transmitter - compact - GMR, analogue output xxx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021488/02/06 Wind Direction Transmitter - compact - GMR, analogue output - 4.3129.60.xxx ADOLF THIES

More information

OPTITEMP TT 20 Technical Datasheet

OPTITEMP TT 20 Technical Datasheet OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is

More information

Aquatrak Model 9002 Tide and Meteorological Station

Aquatrak Model 9002 Tide and Meteorological Station Aquatrak Model 9002 Tide and Meteorological Station Whether you want to measure your local tide and meteorological conditions, develop a regional or national network of stations or participate in a worldwide

More information

QAC910. Meteo Sensor. Synco living

QAC910. Meteo Sensor. Synco living 2 702 Synco living Meteo Sensor QAC910 Wireless sensor for acquiring outside temperature and atmospheric pressure RF communication based on KNX standard (868 MHz, unidirectional) Battery-powered by commercially

More information

current transformers or VAC secondary voltage from our SIGNAL CONVERTERS Selection Chart

current transformers or VAC secondary voltage from our SIGNAL CONVERTERS Selection Chart NK Technologies ADC series signal converters use sensor outputs (4 0 ma, 0 5 and 0 10 VDC) and convert these to digital RS485 outputs. The CTC series accept either 5 A secondary current from Analog to

More information

1-Wire Addressable Digital Instruments. for Environmental Monitoring

1-Wire Addressable Digital Instruments. for Environmental Monitoring 1-Wire Addressable Digital Instruments for Environmental Monitoring Several 1-Wire analog-to-digital converters (ADCs) have recently been introduced that make it possible to measure a wide range of environmental

More information

Wind Direction Transmitter - compact

Wind Direction Transmitter - compact THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021542/06/05 Wind Direction Transmitter - compact 4.3129.03.141 4.3129.53.141 ADOLF THIES GmbH & Co.

More information

Temperature Sensor Tri-Clamp

Temperature Sensor Tri-Clamp 1 Product Information TfP-47, -67, -167 Temperature Sensor Tri-Clamp f o o d Application / Specified Usage Authorizations Temperature Measurement in vessels and pipes Application Examples Monitoring of

More information

Lesson 4 Examples of the Sensors. Chapter-7 L04: "Internet of Things ", Raj Kamal, Publs.: McGraw-Hill Education

Lesson 4 Examples of the Sensors. Chapter-7 L04: Internet of Things , Raj Kamal, Publs.: McGraw-Hill Education Lesson 4 Examples of the Sensors 1 Temperature Measuring and Control sensors Thermistor applications in home automation Sensing the cloud cover The output of thermistor connected to circuit of a signal

More information

MINI MCR-SL-UI-I-LP-NC

MINI MCR-SL-UI-I-LP-NC 2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.

More information

Temperature Sensor G1/2" Standard

Temperature Sensor G1/2 Standard SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-40, -50, -60, -160, -180 FOOD Temperature Sensor G1/2" Standard Application / Specified Usage Temperature measurement in vessels and pipes No product

More information

Temperature Sensor G1/2" Standard

Temperature Sensor G1/2 Standard 1 Product Information TfP-40, -50, -60, -160, -180 Temperature Sensor G1/2" Standard f o o d Application / Specified Usage Authorizations Temperature measurement in vessels and pipes No product contacting

More information

SENSORS CLIMATRONICS CORPORATION (631) MANUAL HEATED SONIC ANEMOMETER P/N M Rev A 2.0 INSTALLATION 1.

SENSORS CLIMATRONICS CORPORATION (631) MANUAL HEATED SONIC ANEMOMETER P/N M Rev A 2.0 INSTALLATION 1. SENSORS MANUAL HEATED SONIC ANEMOMETER P/N M102622 Rev A 1.0 INTRODUCTION Climatronics heated sonic anemometer is designed as a stand-alone sensor to provide accurate measurements of wind speed and wind

More information

Room sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Room sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range 1 857 1857P01 QFA20 Room sensors For relative humidity and temperature QFA20 Operating voltage AC 24 V or DC 13.5 35 V Signal output DC 0...10 V for relative humidity Signal output DC 0...10 V or LG-Ni

More information

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building

More information

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QFM21... Duct sensors. Symaro. for relative humidity and temperature 1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10

More information

Operating Manual Non Invasive Road Sensor NIRS31-UMB English

Operating Manual Non Invasive Road Sensor NIRS31-UMB English English Non Invasive Road Sensor NIRS31-UMB Please read this Operating Manual in its entirety before commissioning the equipment. www.lufft.com G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany.

More information

Technical Information Nivector FTC968, FTC968Z

Technical Information Nivector FTC968, FTC968Z TI0007F/00/EN/7.6 7494 Products Solutions Services Technical Information Nivector FTC968, FTC968Z Capacitance Point level switch for powder and fine-grained bulk solids Application The Nivector is a small-sized

More information

Pressure Transmitter SIL

Pressure Transmitter SIL Pressure Transmitter SI Characteristics - TRANSDUCER - Pressure: Range: Output: Accuracy: Temperature of medium: Material enclosure: Pressure connection: Electrical connection: Protection: relative / absolute

More information

user leaflet ABSOLUTE TTL MODULE

user leaflet ABSOLUTE TTL MODULE user leaflet ABSOLUTE TTL MODULE Product Description Introduction The Solartron ATM transducer comprises a sensor and conditioning electronics which provides an RS422 level square wave output. Each output

More information

OPTITEMP. Compact sensors

OPTITEMP. Compact sensors OPTITEMP Compact sensors High process accuracy thanks to great long-term stability, quick response time and high measuring accuracy High reliability due to the robust design Small form factor, suitable

More information

TLS-A. Laurel Electronics, Inc. Triple output loop splitter. Connection details and general information

TLS-A. Laurel Electronics, Inc. Triple output loop splitter. Connection details and general information Laurel Electronics, Inc. 3183-G Airway Avenue, Costa Mesa, CA 92626 Tel 714 434-6131 Fax 714 434-3766 www.laurels.com Triple output loop splitter TLS-A Connection details and general information 1 2 3

More information

QPM Series Indoor Air Quality Duct Sensors

QPM Series Indoor Air Quality Duct Sensors Document No. CE1N1962 QPM Series Indoor Air Quality Duct Sensors Description The QPM Series Room Carbon Dioxide (CO 2 ) and Air Quality Duct Sensors are designed for applications where precise, stable

More information

Wind Direction Transmitter - compact - with serial output x0.x00

Wind Direction Transmitter - compact - with serial output x0.x00 THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021450/11/05 Wind Direction Transmitter - compact - with serial output - 4.3129.x0.x00 ADOLF THIES

More information

Wind Transmitter First Class Advanced Classified according to IEC ( )

Wind Transmitter First Class Advanced Classified according to IEC ( ) THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021519/01/09 Wind Transmitter First Class Advanced Classified according to IEC 61400-12-1 (2005-12)

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ULTRASONIC ANEMOMETER MODEL 86106 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com

More information

Wind Transmitter - with frequency output xx.xxx

Wind Transmitter - with frequency output xx.xxx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021531/11/09 Wind Transmitter - with frequency output 4.3303.xx.xxx ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Product Certificate Gealog Automatic Weather Station. Gealog Automatic Weather Station. Pic. 1: Applications of Gealog Automatic Weather Stations

Product Certificate Gealog Automatic Weather Station. Gealog Automatic Weather Station. Pic. 1: Applications of Gealog Automatic Weather Stations Pic. 1: Applications of s Page 1 of 17 General The monitoring of the earth s athmosphere is one of the most important tasks, especially at present, where the climate change causes worldwide problems by

More information

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ). ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,

More information

Moving Test - MT3000

Moving Test - MT3000 Moving Test - MT3000 Three-Phase Portable Test System Keep ahead with Modular Design The Modular Concept The MT3000 is based on a real modular design concept to provide the greatest possible flexibility

More information

Pharma-Temperature Sensor M12 hygienic

Pharma-Temperature Sensor M12 hygienic SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-42P, -52P, -62P, -162P, -182P PHARMA Pharma-Temperature Sensor M12 hygienic Application/Specified usage Temperature measurement in pipes DN15...DN80

More information

Support of Absolute Encoders. with SSI / BiSS-C interface

Support of Absolute Encoders. with SSI / BiSS-C interface APPLICATIONNOTE 158 Support of Absolute Encoders with SSI / BiSS-C interface Summary Faulhaber AES encoders with 12 bit resolution are natively supported by Faulhaber controllers. For third party absolute

More information

M-2111 Series Ultrasonic Flow Meter

M-2111 Series Ultrasonic Flow Meter M-2111 Series Ultrasonic Flow Meter High Accuracy/Non-contact Flow Sensing in PFA Key Features Accuracy ± 1% of reading Repeatability ± 0.5% of reading All wetted parts made of New PFA (AP- 211SH) Contamination

More information

Wind Transmitter First Class / 141 / / 141 / 161

Wind Transmitter First Class / 141 / / 141 / 161 THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021436/01/07 Wind Transmitter First Class 4.3350.00.140 / 141 / 161 4.3350.10.140 / 141 / 161 ADOLF

More information

Temperature Sensor with M12 hygienic

Temperature Sensor with M12 hygienic 1 Product Information TFP-42, -52, -62, -162, -182 Temperature Sensor with M12 hygienic FOOD Application / Specified Usage Authorizations Temperature Measurement in pipes DN15...DN80 Temperature measurement

More information

T40FH. Torque flange. Special features. Data sheet

T40FH. Torque flange. Special features. Data sheet T40FH Torque flange Special features - Nominal (rated) torques: 100kNm, 125kNm, 150kNm, 200kNm, 250kNm, 300kNm - Nominal (rated) rotational speed of 2000 rpm up to 3000 rpm - Compact design - Version for

More information

Electronic Thermostat TE-1 Version according to EN

Electronic Thermostat TE-1 Version according to EN JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 e-mail: mail@jumo.net Internet: www.jumo.net JUMO

More information

Antenna POD 16. Antenna POD 618. Antenna Stand for Site VSWR Measurements MANUAL. POD - Precision Omnidirectional Dipole

Antenna POD 16. Antenna POD 618. Antenna Stand for Site VSWR Measurements MANUAL. POD - Precision Omnidirectional Dipole Antenna POD 16 Antenna POD 618 Antenna Stand for Site VSWR Measurements MANUAL POD - Precision Omnidirectional Dipole EMC & OPTICS MANUAL POD Precision Omnidirectional Dipole Antenna POD 16 Antenna POD

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Temposonics. Magnetostrictive Linear Position Sensors. ER IO-Link Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ER IO-Link Data Sheet Temposonics Magnetostrictive Linear Position Sensors ER IO-Link Compact sensor model Operating temperature up to +75 C (+167 F) Ideal for flexible mounting MEASURING TECHNOLOGY The absolute, linear position

More information

F T 742 NEW TOUGHEST WIND SENSORS THE WORLD S

F T 742 NEW TOUGHEST WIND SENSORS THE WORLD S F T 7 2 2+ F T 742 D ATA S H E E T NEW D E S I G N E D F O R T U R B I N E C O N T R O L THE WORLD S TOUGHEST WIND SENSORS WWW.FTTECHNOLOGIES.COM PROVEN NEW LOOK, NEW SPEED, SAME STRENGTH The FT722 and

More information

Flow sensor HVAC 100 (548000) Instruction for use. Imprint: Copyright all rights reserved Version Subject to modifications

Flow sensor HVAC 100 (548000) Instruction for use. Imprint: Copyright all rights reserved Version Subject to modifications Flow sensor HVAC 100 (548000) Instruction for use Imprint: Copyright 2017 - all rights reserved Version 547996.02 Subject to modifications Important Information These instructions for use must be read

More information

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S. EN SolidFlow.0 Product Information Solid mass flow measurement SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.A Group Use SolidFlow.0 has been specially developed for measuring

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ULTRASONIC ANEMOMETER MODEL 86004 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com

More information

Magnetic-Inductive flow Meter fmi

Magnetic-Inductive flow Meter fmi 1 Product information fmi-c, fmi-r f o o d P H A R M A Magnetic-Inductive flow Meter fmi Application/Specified usage Magnetic-inductive flowmeter for the measurement of flow rate and volume in food and

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS SERIAL INTERFACE MODEL 32400 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com

More information

LASER. Analog Laser Displacement Transducer. LAS Series. Key-Features:

LASER. Analog Laser Displacement Transducer. LAS Series. Key-Features: LASER Analog Laser Displacement Transducer LAS Series Key-Features: Content: Measurement Principle & Installation...2 Overview of the Series...3 Technical Data.4 Technical Drawing...7 Linearity & Resolution...8

More information

Temperature Sensor with M12 hygienic

Temperature Sensor with M12 hygienic SENSORS FOR AND BIOPHARMA. Product Information TFP-42, -52, -62, -162, -182 Temperature Sensor with M12 hygienic Application / Specified Usage Temperature Measurement in pipes DN15...DN80 Temperature measurement

More information

Online data sheet GM35 IN-SITU GAS ANALYZERS

Online data sheet GM35 IN-SITU GAS ANALYZERS Online data sheet GM35 C D E F Ordering information Type GM35 Part no. On request The exact device specifications and performance data of the product may deviate from the information provided here, and

More information

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm) Products Handheld Measuring Instruments Digital PIEZOVAC Sensor PV 101 Digital THERMOVAC Sensor TM 101 The digital compact PIEZOVAC PV 101 and THERMOVAC TM 101 combine high-quality sensor technology with

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ELECTRONIC COMPASS W/ SERIAL INTERFACE MODEL 32500 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS ULTRASONIC ANEMOMETER MODEL 86004 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com

More information

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC) 6ES7214-1AG31-0XB0 Page 1 Product data sheet 6ES7214-1AG31-0XB0 SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V

More information

TEMPERATURE SWITCHES AND SENSORS BIMETAL TEMPERATURE SWITCHES ELECTRONIC TEMPERATURE SWITCHES ELECTRONIC TEMPERATURE SENSORS SCREW-IN RESISTORS

TEMPERATURE SWITCHES AND SENSORS BIMETAL TEMPERATURE SWITCHES ELECTRONIC TEMPERATURE SWITCHES ELECTRONIC TEMPERATURE SENSORS SCREW-IN RESISTORS In touch with the medium TEMPERATURE SWITCHES AND SENSORS BIMETAL TEMPERATURE SWITCHES ELECTRONIC TEMPERATURE SWITCHES ELECTRONIC TEMPERATURE SENSORS SCREW-IN RESISTORS 2 www.bedia.com CONTENT The company

More information