Combi sensor C B1. A: Wind wheel. west, east, south C: Dawn sensor D: Rain sensor. Ref.-No. with DCF77 receiver WS 10 KSDCF (No KNX device)

Size: px
Start display at page:

Download "Combi sensor C B1. A: Wind wheel. west, east, south C: Dawn sensor D: Rain sensor. Ref.-No. with DCF77 receiver WS 10 KSDCF (No KNX device)"

Transcription

1 Combi sensor A B D C B B A: Wind wheel B... B: Brightness sensors west, east, south C: Dawn sensor D: Rain sensor Combi sensor WS 0 KS with DCF77 receiver WS 0 KSDCF The combi sensor serves for the measurement of the wind speed, brightness dawn and rain. The brightness can be measured for three directions, south, east and west, separately. The combi sensor will be connected directly to the weather station ( REG W) which evaluates the measured and transmits these as switching or value telegrams to the bus. The combi sensor WS 0 KSDCF includes an additional DCF77 receiver for the official German time signal. The combi sensor needs an external V AC supply, e.g. power supply WSSV 0. Supply: V AC ± 5 %, 50/60 Hz Max. current consumption: 600 ma Power consumption: max.. W (sensors and heating) Ambient temperature: 5 C C Connection cable: LiYCY, 6 x 0.5 mm, 0 m, max. 50 m Ambient temperature: 0 C C, ice free Storage/transport temperature: 0 C C Protection: IP 55, in standard purpose acc. to DIN EN 6059 Safety class: III Dimensions: 0 x 00 mm (without mounting bracket) Fastening: mounting bracket for wall or mast Sensor signals Wind speed: Accuracy: Rain: Sensitivity: Switch On delay: Switch Off delay: Brightness Spectral range: Resolution: Direction: Dawn Resolution:... 0 m/s 0.5 m/s, 0 C C Yes / No fine drizzle approx. rain particles approx. minutes KLux nm 0 bit east, south, west Lux 0 bit 6

2 Analog Sensors for Weather Station Wind sensor brown operating volt. + V white correspond. ground green output 0 V / 0 V yellow correspond. ground pink heating V grey heating V WS 0 W The wind sensor converts the wind speed into electrical signals. These signals are generated by a Reed contact which closes under the influence of magnets. The generated impulses are transformed into an output voltage proportional to the wind speed. A PTC-heating element takes care for a trouble free winter operation (only in combination with heating transformer WSSV 0). 0, m/s V at 0 m/s Supply voltage: 8... V DC Current consumption: 6... ma Contact type: Reed contact Heating: PTC-element (800 C) Operating voltage heating: V AC/DC Lead wire: m (LIYY 6 x 0.5 mm ) 7

3 Analog Sensors for Weather Station Rain sensor brown operating volt. + V white correspond. ground green output 0 V / 0 V yellow heating V grey heating V WS 0 R The rain sensor is used for the measuring and evaluation of the rainfall. With a meander shaped sensor the conductance of the rain water is evaluated. A micro processor controls the heating (only in combination with heating transformer WSSV 0) and offers an output signal of 0 V or 0 V. Range of the electrical output: 0 V dry / 0 V rain (min. kω load) Lead wire: m (LIYY 5 x 0.5 mm ) with sealed electronics 8

4 Weather station WS 0.. Brightness sensor operating volt. + V correspond. ground output V WS 0 H The brightness sensor is used for the measuring and evaluation of the brightness. The brightness measured by a photodiode is transmitted to an analog output signal of 0 V 0 V by the electronics Lux, linear 0 V... 0 V, short-circuit / proof with PG7 thread + screw and pressure respectively moisture compensation (recommended cable x 0.5 mm ) Dawn sensor operating volt. + V correspond. ground output V WS 0 D The dawn sensor is used for the measuring and evaluation of the brightness (dawn/dusk). The brightness measured by a photodiode is transmitted to an analog output signal of 0 V 0 V by the electronics Lux, linear 0 V... 0 V, short-circuit / proof with PG7 thread + screw and pressure respectively moisture compensation (recommended cable x 0,5 mm ) 9

5 Weather station WS 0.. Temperature sensor operating volt. + V correspond. ground output V WS 0 T The temperature sensor is used for the measuring and evaluation of the temperature. The temperature measured by a temperature sensor is transmitted to an analog output signal of 0 V 0 V by the electronics. 0 C C, linear 0 V... 0 V, short-circuit / proof with PG7 thread + screw and pressure respectively moisture compensation (recommended cable x 0.5 mm ) 0

Operating Instructions. Combination sensor

Operating Instructions. Combination sensor Operating Instructions 1. Safety warnings Attention: Electrical equipment must be installed and fitted by qualified electricians only and in strict observance of the relevant accident prevention regulations.

More information

Operating Instructions Wind Sensor with Heating Heating Transformer Rain Sensor

Operating Instructions Wind Sensor with Heating Heating Transformer Rain Sensor Operating Instructions Wind Sensor with Heating Heating Transformer Rain Sensor 2 1. Safety instructions Attention: Electrical equipment must be installed and fitted by qualified electricians only. 2.

More information

Wind Transmitter compact xx

Wind Transmitter compact xx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021720/03/14 Wind Transmitter compact 4.3519.xx.140... 961 Contents 1 Models... 3 2 Application...

More information

KNX/EIB Product documentation

KNX/EIB Product documentation Page: 1 of 87 Weather Station Sensor Product name: Weather station Design: REG (series mounting) Part no: 2224 REG W ETS search Input/Analog input/weather station path: Phys. sensors/weather station/weather

More information

Wind Direction Transmitter - compact - GMR, analogue output xxx

Wind Direction Transmitter - compact - GMR, analogue output xxx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021488/02/06 Wind Direction Transmitter - compact - GMR, analogue output - 4.3129.60.xxx ADOLF THIES

More information

Precipitation Monitor ,

Precipitation Monitor , THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 021197/11/09 Precipitation Monitor 5.4103.10.000, 5.4103.10.700 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Brightness Transmitter

Brightness Transmitter THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 021328/05/10 Brightness Transmitter 7.1414.51.150 7.1414.51.550 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Wind Transmitter First Class

Wind Transmitter First Class THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021310/07/06 Wind Transmitter First Class 4.3350.00.000 4.3350.10.000 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Wind Transmitter compact xx

Wind Transmitter compact xx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021075/08/11 Wind Transmitter compact 4.3519.xx.140... 961 ADOLF THIES GmbH & Co. KG Hauptstraße 76

More information

Wind Direction Transmitter - compact - with serial output x0.x00

Wind Direction Transmitter - compact - with serial output x0.x00 THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021450/11/05 Wind Direction Transmitter - compact - with serial output - 4.3129.x0.x00 ADOLF THIES

More information

Wind Direction Transmitter - compact

Wind Direction Transmitter - compact THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021542/06/05 Wind Direction Transmitter - compact 4.3129.03.141 4.3129.53.141 ADOLF THIES GmbH & Co.

More information

Precipition Sensor with analogue Intensity Output ,

Precipition Sensor with analogue Intensity Output , THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 021335/11/09 Precipition Sensor with analogue Intensity Output 5.4103.20.041, 5.4103.20.741 ADOLF THIES

More information

Wind Transmitter - compact

Wind Transmitter - compact THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021194/02/07 Wind Transmitter - compact 4.3518.03.000 4.3519.03.000 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that

More information

KINAX SR 719 Programmable Transmitter for Position Feedback

KINAX SR 719 Programmable Transmitter for Position Feedback Position transmitter with NAMUR valve fitting Application The position feedback transmitter KINAX SR 719 (Figs. 1 and 2) is used to measure and transmit linear displacement (stroke) on various types of

More information

WIND VANE THIES COMPACT TMR

WIND VANE THIES COMPACT TMR WIND VANE THIES COMPACT TMR ORDER - N O ELECTRICAL OUTPUT ELECTRICAL SUPPLY HEATING SUPPLY MODEL IN EOL MANAGER 4.3129.60.773 0 5V 4.3129.70.773 0 5V 4.3129.60.173 0 5 V 8 30 VDC/ 24 VAC

More information

Weather Station for KNX

Weather Station for KNX Weather Station for KNX Installation and Adjustment Product description... 3 Technical data... 3 PCB layout...5 230 V AC version... 5 24 V DC version... 6 Installation and commissioning... 7 Location...

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021488/06/09 Wind Direction Transmitter - compact - GMR, analogue output - 4.3129.60.xxx 4.3129.80.xxx

More information

Binary Inputs. Ref.-No. KNX universal binary input, 8-gang. ETS-product family: Series embodiment (SE-) device (2 units) Ref.-No.

Binary Inputs. Ref.-No. KNX universal binary input, 8-gang. ETS-product family: Series embodiment (SE-) device (2 units) Ref.-No. Binary s 1 L1 L2 L3 N E1 N1 E2 N2 E3 N3 E4 N4 KNX + - 2 1 KNX universal binary input, 4-gang ETS-product family: Product type: Series embodiment (SE-) device (2 units) Ref.-No. 2114 REG 4-gang binary input

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

SI-JET Series SI-JET3-CON8 A-LAS-M C A-LAS-M C. Design. SI-JET Series Spray Jet Control Sensors. Product name:

SI-JET Series SI-JET3-CON8 A-LAS-M C A-LAS-M C. Design. SI-JET Series Spray Jet Control Sensors. Product name: SI-JET Series SI-JET3-CON8 A-LAS-M12-...-C A-LAS-M18-...-C By way of the analog laser light barriers of type A-LAS-M12 or A-LAS-M18, the SI-JET3-CON8 Spray Jet Monitoring System monitors the density and

More information

Wind Transmitter First Class Advanced Classified according to IEC ( )

Wind Transmitter First Class Advanced Classified according to IEC ( ) THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021519/01/09 Wind Transmitter First Class Advanced Classified according to IEC 61400-12-1 (2005-12)

More information

Wind Direction Transmitter First Class analogue output x0.1xx

Wind Direction Transmitter First Class analogue output x0.1xx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021514/03/09 Wind Direction Transmitter First Class analogue output 4.3150.x0.1xx ADOLF THIES GmbH

More information

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device MINIPAN digital panel meters, temperature- and mains controlling, special purpose instruments for customer requirements www.ziehl.com Operating manual PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor

More information

M70LL Laser Distance Sensor

M70LL Laser Distance Sensor M7LL Laser Distance Sensor for automated manufacturing with Ethernet interface to connect with PLC The analog sensors of series M7LL use a PSD for their receiver optics. This assures a position measurement

More information

ABB i-bus KNX Weather Sensor, SM WES/A 3.1, 2CDG120046R0011

ABB i-bus KNX Weather Sensor, SM WES/A 3.1, 2CDG120046R0011 Technical Data 2CDC504093D0202 ABB i-bus KNX Product description The Weather Sensor WES/A 3.1 detects primarily in the residential sector wind speed, rain, brightness in three directions, twilight, temperature

More information

Installation and user manual EFIT 850 sensor

Installation and user manual EFIT 850 sensor Installation and user manual EFIT 850 sensor GB-DAS 1 Table of content 1 Sensors and control zones 3 1.1 Sensor types and function 3 1.2 Control zones 4 1.3 Assign sensors to control zones 5 2 Placing

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Wind Direction Transmitter - compact - TMR, analogue output x.xxx xxx

Wind Direction Transmitter - compact - TMR, analogue output x.xxx xxx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021488/12/13 Wind Direction Transmitter - compact - TMR, analogue output - 4.3129.6x.xxx 4.3129.80.xxx

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control dampers

More information

THE WORLD OF WEATHER DATA Measurement and Documentation: Thies range of service for meteorology, environmental protection and industry

THE WORLD OF WEATHER DATA Measurement and Documentation: Thies range of service for meteorology, environmental protection and industry T H E W O R L D O F W E A T H E R D A T A THE WORLD OF WEATHER DATA Measurement and Documentation: Thies range of service for meteorology, environmental protection and industry Today more than ever the

More information

Absolute encoders - analog Blind hollow shaft ø12 mm Magnetic single- or multiturn encoders 12 bit ST / 16 bit MT

Absolute encoders - analog Blind hollow shaft ø12 mm Magnetic single- or multiturn encoders 12 bit ST / 16 bit MT Blind hollow shaft ø mm Magnetic single- or multiturn encoders bit ST / bit MT BMSH 8, BMMH 8 analog - MAGRES Features Encoder single- or multiturn / analog Magnetic sensing Resolution: singleturn bit,

More information

Introduction. Applications

Introduction. Applications Introduction In meteorology, the precision of measurement data parameters is critical for accurate weather forecasting and environmental research. ROTRONIC meteorological probes have an excellent reputation

More information

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Direction Transmitter - compact - with Poti Output xx.712 THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021434/06/06 Wind Direction Transmitter - compact - with Poti Output - 4.3129.xx.712 ADOLF THIES GmbH

More information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.

More information

WIND VANE THIES FIRST CLASS 2014 TMR

WIND VANE THIES FIRST CLASS 2014 TMR WIND VANE THIES FIRST CLASS 2014 TMR ORDER - N O ELECTRICAL OUTPUT ELECTRICAL SUPPLY HEATING SUPPLY MODEL IN EOL MANAGER 4.3151.00.173 0...5 V 4.3151.10.173 0...5 V 12 24 VDC 4.5 ma + Iout 12 24 VDC 4.5

More information

Meteodata 140 S weather station

Meteodata 140 S weather station Meteodata 140 S weather station Meteodata 140 S 1409207 Meteodata 140 S 24V 1409201 Meteodata 140 S GPS 1409208 Meteodata 140 S 24V GPS 1409204 As at: Apr-18 (Subject to change) Page 1 of 95 Contents 1

More information

Wind Transmitter First Class / 141 / / 141 / 161

Wind Transmitter First Class / 141 / / 141 / 161 THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021436/01/07 Wind Transmitter First Class 4.3350.00.140 / 141 / 161 4.3350.10.140 / 141 / 161 ADOLF

More information

Technical data. General specifications. Measurement range min max. 360

Technical data. General specifications. Measurement range min max. 360 Model Number Features Very small housing High climatic resistance 12 Bit singleturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

Smart Power Relay E I...

Smart Power Relay E I... Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic

More information

WIND T H E W O R L D O F W E A T H E R D A T A

WIND T H E W O R L D O F W E A T H E R D A T A WIND T H E W O R L D O F W E A T H E R D A T A THE WORLD OF WEATHER DATA Measurement and Documentation: Thies range of service for meteorolgy, environmental protection and industry Today more than ever,

More information

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.: Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer

More information

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv When temperatures are to be measured using Pt100 resistance thermometers in high-voltage environments, standard temperature transmitters

More information

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

Cable transducer Analog output / redundant Measuring length absolute up to 5 m Features Magnetic sensing method Resolution: 12 bit Interface analog 0...10 V / 0.. V /...20 ma Measuring length up to m Removable stickers for water outlet Teach inputs Extremely light thanks to housing

More information

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O echnical data sheet NRF24A-SR-S2(-O) Modulating rotary actuator with emergency function for 2- and 3-way ball valves orque or ue 10 Nm Nominal voltage AC/DC 24 V Control: modulating DC 0... 10 V Position

More information

PAL VERSION CEC-WP-PV49AB NTSC VERSION CEC-WP-NV49AB CEC-WP-C38 CEC-WP-C60 CEC-WP-CV48 CEC-WP-CV48A CEC-WP-E38 CEC-WP-E60 CEC-WP-EV48 CEC-WP-EV48A

PAL VERSION CEC-WP-PV49AB NTSC VERSION CEC-WP-NV49AB CEC-WP-C38 CEC-WP-C60 CEC-WP-CV48 CEC-WP-CV48A CEC-WP-E38 CEC-WP-E60 CEC-WP-EV48 CEC-WP-EV48A NTSC VERSION CEC-WP-NV49AB EIA VERSION CEC-WP-E38 CEC-WP-E60 CEC-WP-EV48 CEC-WP-EV48A PAL VERSION CEC-WP-PV49AB CCIR VERSION CEC-WP-C38 CEC-WP-C60 CEC-WP-CV48 CEC-WP-CV48A 1 Thank you for your purchase

More information

Wind Transmitter - with frequency output xx.xxx

Wind Transmitter - with frequency output xx.xxx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021531/11/09 Wind Transmitter - with frequency output 4.3303.xx.xxx ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Instruction for Use /05/09. Wind Transmitter - compact x0.xxx x0.xx x0.xx0

Instruction for Use /05/09. Wind Transmitter - compact x0.xxx x0.xx x0.xx0 Instruction for Use 021094/05/09 Wind Transmitter - compact 4.3518.x0.xxx 4.3519.x0.xx0 4.3520.x0.xx0 Safety Instructions Environment Before operating with or at the device/product, read through the operating

More information

KNX weather station basic V2

KNX weather station basic V2 KNX weather station basic V2 KNX weather station basic V2 MEG6904-0001 As at: Dec 16 (Subject to change) Page 1 of 88 Contents 1 Functional characteristics... 3 1.1 Special features... 3 1.2 Important

More information

Totalizing Counters mini-i

Totalizing Counters mini-i mini-i Type 634/635 Type 634: Counter with high immunity against magnetic interfere Type 635: Counter with high shock stability Miniature size Low power consumption Electrical connections in standard grid

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

PA-850 PRESSURE TRANSDUCERS WITH AMP. PA R - N R2 FEATURES MODEL NUMBER DESIGNATION

PA-850 PRESSURE TRANSDUCERS WITH AMP. PA R - N R2 FEATURES MODEL NUMBER DESIGNATION INTERNAL STRUCTURE (R 1/4) 4 1 2 3 Part name Material 1 2 FEATURES 3 4 Stainless steel diaphragm ABS (Acrylonitrile butadiene styrene) + PC (Polycarbonate) High corrosion resistance and drip-proof construction

More information

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Direction Transmitter - compact - with Poti Output xx.712 THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021434/05/09 Wind Direction Transmitter - compact - with Poti Output - 4.3129.xx.712 ADOLF THIES GmbH

More information

Protection class IP67/IP69K Magnetic measurement principle

Protection class IP67/IP69K Magnetic measurement principle POSITILT PTAS2 Magnetic inclination sensor with analog output Magnetic inclination sensor in a 36 mm housing Protection class IP67/IP69K Magnetic measurement principle Outputs: Voltage 0.5... 4.5 V; 0.5...

More information

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description. Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed

More information

Product data sheet Palas Fidas 200 E

Product data sheet Palas Fidas 200 E Product data sheet Palas Fidas 200 E Applications Regulatory environmental monitoring in measuring networks Ambient air measurement campaigns Long-term studies Emission source classification Distribution

More information

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders 18 bit ST / 12 bit MT

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders 18 bit ST / 12 bit MT Features High resolution encoder multiturn / SSI Optical sensing method Resolution: singleturn 18 bit, multiturn 12 bit Electronic setting of zero point Counting direction input Available with additional

More information

5-pole M12 connector. Connecting cable: cab-m12/5-g-2m. LED (red) for dirt accumulation indication

5-pole M12 connector. Connecting cable: cab-m12/5-g-2m. LED (red) for dirt accumulation indication D-LAS Series D-LAS-34-ED-25x2-AC-T (Glass Pane Detection) - Collimated laser beam (

More information

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C. ProLine Interface Technology Transducers for High Voltage / Shunt Applications Compact high voltage transducers with VariPower broad-range power supply and genuine calibrated range selection. The Task

More information

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT Features Encoder multiturn / SSI Optical sensing method Resolution: max. singleturn 14 bit, multiturn 16 bit Clamping or synchro flange Electronic setting of zero point Counting direction input Available

More information

Thermocouple - Transducer

Thermocouple - Transducer Thermocouple - Transducer TM3 Characteristics: Thermocouple type J, K, R, S, T, E, B, N Linearity error < 1% Measurement range configurable -210...+1820 C Built-in cold junction compensation Galvanic 3-way

More information

Moeller Electric Corporation

Moeller Electric Corporation EMR4-I Current Monitoring Relays 02/0053 EMR4-I1-2-A EMR4-I15-2-A EMR4-I15-2-B Mechanical lifespan operations x10 6 30 30 30 24-h cycle, 55 C, 93 % relative humidty, 96 h Ambient temperature min./max.

More information

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

Pressure measurement PBMR Fully welded pressure transmitter for railway applications Fully welded pressure transmitter for railway Product highlights Ecellent accuracy and long term stability up to % FS Active temperature compensation over the entire operating temperature range Sensor

More information

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT Features Encoder multiturn / SSI Optical sensing method Resolution: max. singleturn 14 bit, multiturn 16 bit Clamping or synchro flange Electronic setting of zero point Counting direction input Available

More information

RoHS. High shaft load capacity. Shock / vibration resistant

RoHS. High shaft load capacity. Shock / vibration resistant Due to their sturdy bearing construction in Safety Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up

More information

Pressure transmitter AKS 32 and AKS 33

Pressure transmitter AKS 32 and AKS 33 Data sheet Pressure transmitter AKS 32 and AKS 33 AKS 32 and AKS 33 are pressure transmitters that measure a pressure and convert the measured value to a standard signal: y 1 5 V DC or 0 10 V DC for AKS

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL acc. to IEC

More information

Operating Instruction

Operating Instruction Level and Pressure Operating Instruction VEGASEL 643 6 5 + + 3 5 + + max. min. on VEGASEL 643 5 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 1 Product description 1.1 Function

More information

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a The Heavy Duty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS

More information

Absolute encoders - SSI

Absolute encoders - SSI with through hollow shaft Features Encoder multiturn / SSI Optical sensing method Resolution: singleturn 14 bit, multiturn 12 bit Compact design Cost-efficient mounting High reliability by self-diagnostics

More information

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001 , GH Q605 0062 R0001 The 2-fold week time switch is a DIN rail mounted device with a width of two modules for insertion in the distribution board. It is connected to the EIB via a bus connecting terminal.

More information

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces: Valve amplifier for proportional valves Type VT-MSPA2-1 RE 30228 Edition: 2014-01 Replaces: 2011-04 Component series 1X Suitable for controlling direct operated proportional directional valves without

More information

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage Application The transducers SINEAX I 503/U 504 (Figs. 1 and 2) are designed to convert a sinusoidal AC current or voltage into a load independent DC signal proportional to the measured value. This output

More information

Pressure Transmitter SIL

Pressure Transmitter SIL Pressure Transmitter SI Characteristics - TRANSDUCER - Pressure: Range: Output: Accuracy: Temperature of medium: Material enclosure: Pressure connection: Electrical connection: Protection: relative / absolute

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Electrical devices may only be mounted and connected by electrically skilled persons.

Electrical devices may only be mounted and connected by electrically skilled persons. Order No. : 2126 00 Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible.

More information

Functional data Factory settings Variable Settings

Functional data Factory settings Variable Settings echnical data sheet Rotary actuator RF-MF(-O) Multifunctional rotary actuator with emergency control for and 3 way control ball valve orque Nm Nominal voltage AC/DC V Control: Modulating DC... V or variable

More information

Measuring and Controlling Unit Multronic OC

Measuring and Controlling Unit Multronic OC Measuring and Controlling Unit Multronic OC One channel measuring and controlling unit for ph / conductivity / Chlorine measuring Automatic temperature compensation Measuring and control behaviour simultaneously

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays KSR-Level sensor KSR-Schwimmer-Magnetschalter 1001-5 KSR Contact Protection s 1 KSR Contact Protection Type KR230-Ex and KR24-Ex General Description The contact protection relays KR230-Ex and KR24-Ex transmit

More information

Light Management Systems for Indoor Use MULTISENSORS

Light Management Systems for Indoor Use MULTISENSORS Light Management Systems for Indoor Use MULTISENSORS MULTISENSORS Daylight and motion sensors both enable greater energy savings to be made and increase the convenience factor. For this reason, we have

More information

Local control stations for Zone 1 and Zone 21. Features. Description

Local control stations for Zone 1 and Zone 21. Features. Description Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning

More information

Coupling Relays and Converters

Coupling Relays and Converters Overview Area of application In automation and control engineering it will always be necessary to work with analog signals. The interfaces for analog signals that have established themselves as the standard

More information

WIND VANE THIES COMPACT

WIND VANE THIES COMPACT WIND VANE THIES COMPACT ORDER - N O ELECTRICAL OUTPUT ELECTRICAL SUPPLY HEATING SUPPLY MODEL IN EOL MANAGER 4.3129.00.712 Pot: 2 kω 4.3129.10.712 Pot: 2 kω 4.3129.00.012A 4.3129.10.012A Pot: 2 kω Pot:

More information

Power consumption Operation At rest Wire sizing

Power consumption Operation At rest Wire sizing echnical data sheet NM24P-SR Modulating Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..6 m 2 orque 8

More information

Screw-in resistance thermometers with terminal head Form B

Screw-in resistance thermometers with terminal head Form B Data Sheet 90.2002 Page 1/7 Screw-in resistance thermometers with terminal head Form B for temperatures from -50 to +600 C with replaceable measuring insert as single or twin resistance thermometer terminal

More information

11 Product group. Inductive transducers in cylindrical metal housings A WA F A WA X A WD X A WU X

11 Product group. Inductive transducers in cylindrical metal housings A WA F A WA X A WD X A WU X Inductive s in cylindrical metal housings 11 Product group A WA F A WA X A WD X A WU X Application The inductive is a linear displacement measuring system. It can either be fl ange-mounted at a solenoid

More information

Measuring current transformers of the W AB(P) series

Measuring current transformers of the W AB(P) series Measuring current transformers of the W AB(P) series W-AB(P)_D00074_02_D_XXEN/07.2017 Measuring current transformers of the W AB(P) series Product description Measuring current transformers of the W -AB

More information

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire POSICHRON Position Sensor Stick Design with Analog Specifications POSICHRON position sensor in stick design Protection class IP67 Measurement range 0... 100 up to 0... 5750 mm Absolute position measurement

More information

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum

More information

Product documentation

Product documentation Product documentation Weather station "home" ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Telefon: +49.23 55.8 06-0 Telefax: +49.23 55.8 06-2 04 kundencenter@jung.de www.jung.de Service

More information

Assembly. Front view. Parametrization interface. Power Bus

Assembly. Front view. Parametrization interface. Power Bus Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and

More information

Screw-in resistance thermometers with plug connector

Screw-in resistance thermometers with plug connector Data Sheet 90.2004 Page 1/7 s with plug connector for temperatures from -50 to +300 C highly resistant to shock and vibration connector locked in for reliable contact, IP65 or IP69K protection available

More information

Online data sheet VT12T-2P410 V12-2 CYLINDRICAL PHOTOELECTRIC SENSORS

Online data sheet VT12T-2P410 V12-2 CYLINDRICAL PHOTOELECTRIC SENSORS Online data sheet VTT-P0 V- A B C D E F Illustration may differ Ordering information Type Part no. VTT-P0 606 Other models and accessories www.sick.com/v- H I J K L M N O P Q R S T Detailed technical data

More information

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator ANSI version Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam

More information

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx. General data Mounting Enclosure material On linear actuators On quarter-turn actuators ARCA-integrated or acc. to IEC 534-6 (NAMUR) Range of stroke 10... 120 mm ARCA-integrated or acc. to VDI/VDE 3845

More information

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire Rod Profile with Analog Specifications POSICHRON position sensor in a stainless steel pressure case Protection class IP68 Compression-proof up to 15 bar Measurement range 0... 100 to 0... 5750 mm Absolute

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information